-- TT-LOOP-MIB: ME1200 Private MIB
|
|
--
|
|
--
|
|
-- ****************************************************************
|
|
|
|
ME1200-TT-LOOP-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
MODULE-IDENTITY, OBJECT-TYPE
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
me1200SwitchMgmt
|
|
FROM CISCOME1200-MIB
|
|
ME1200DisplayString FROM ME1200-TC
|
|
ME1200InterfaceIndex FROM ME1200-TC
|
|
ME1200RowEditorState FROM ME1200-TC
|
|
Integer32 FROM SNMPv2-SMI
|
|
Unsigned32 FROM SNMPv2-SMI
|
|
MacAddress FROM SNMPv2-TC
|
|
TruthValue FROM SNMPv2-TC
|
|
;
|
|
|
|
me1200TtLoopMib MODULE-IDENTITY
|
|
LAST-UPDATED "201405190000Z"
|
|
ORGANIZATION
|
|
"Cisco Systems, Inc"
|
|
CONTACT-INFO
|
|
"Cisco Systems, Inc
|
|
Customer Service
|
|
Postal: 170 W Tasman Drive
|
|
San Jose, CA 95134
|
|
USA
|
|
Tel: +1 800 553-NETS
|
|
E-mail: cs-me1200@cisco.com"
|
|
DESCRIPTION
|
|
"This is a private Traffic Test Loop MIB that can be used for RFC2544
|
|
and Y.1564 (remote end) testing"
|
|
REVISION "201612070000Z"
|
|
DESCRIPTION
|
|
"Support for Latching Loopback function: Added
|
|
me1200TtLoopLlConfigInstanceTable."
|
|
REVISION "201405190000Z"
|
|
DESCRIPTION
|
|
"Initial version"
|
|
::= { me1200SwitchMgmt 128 }
|
|
|
|
|
|
ME1200TtLoopInstanceAdminState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance Administrative State."
|
|
SYNTAX INTEGER { adminDisabled(0), adminEnabled(1) }
|
|
|
|
ME1200TtLoopInstanceDirection ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance direction."
|
|
SYNTAX INTEGER { facility(0), terminal(1) }
|
|
|
|
ME1200TtLoopInstanceDomain ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance domain."
|
|
SYNTAX INTEGER { port(0), evc(1), vlan(2) }
|
|
|
|
ME1200TtLoopInstanceOperState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance Operational State."
|
|
SYNTAX INTEGER { operDown(0), operUp(1), operInact(2) }
|
|
|
|
ME1200TtLoopInstanceSubscriber ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance subscriber mode."
|
|
SYNTAX INTEGER { none(0), all(1), test(2) }
|
|
|
|
ME1200TtLoopInstanceType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance type."
|
|
SYNTAX INTEGER { macLoop(0), oamLoop(1) }
|
|
|
|
me1200TtLoopMibObjects OBJECT IDENTIFIER
|
|
::= { me1200TtLoopMib 1 }
|
|
|
|
me1200TtLoopCapabilities OBJECT IDENTIFIER
|
|
::= { me1200TtLoopMibObjects 1 }
|
|
|
|
me1200TtLoopCapabilitiesInstanceMax OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Max number of TT_LOOP instance"
|
|
::= { me1200TtLoopCapabilities 1 }
|
|
|
|
me1200TtLoopCapabilitiesNameMax OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Max length of instance name"
|
|
::= { me1200TtLoopCapabilities 2 }
|
|
|
|
me1200TtLoopConfig OBJECT IDENTIFIER
|
|
::= { me1200TtLoopMibObjects 2 }
|
|
|
|
me1200TtLoopConfigInstanceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200TtLoopConfigInstanceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a table of created instance configuration parameters"
|
|
::= { me1200TtLoopConfig 1 }
|
|
|
|
me1200TtLoopConfigInstanceEntry OBJECT-TYPE
|
|
SYNTAX ME1200TtLoopConfigInstanceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a created instance configuration parameters. Not all parameters
|
|
can be changed"
|
|
INDEX { me1200TtLoopConfigInstanceId }
|
|
::= { me1200TtLoopConfigInstanceTable 1 }
|
|
|
|
ME1200TtLoopConfigInstanceEntry ::= SEQUENCE {
|
|
me1200TtLoopConfigInstanceId Integer32,
|
|
me1200TtLoopConfigInstanceName ME1200DisplayString,
|
|
me1200TtLoopConfigInstanceType ME1200TtLoopInstanceType,
|
|
me1200TtLoopConfigInstanceDirection ME1200TtLoopInstanceDirection,
|
|
me1200TtLoopConfigInstanceDomain ME1200TtLoopInstanceDomain,
|
|
me1200TtLoopConfigInstanceFlow Unsigned32,
|
|
me1200TtLoopConfigInstancePort ME1200InterfaceIndex,
|
|
me1200TtLoopConfigInstanceLevel Unsigned32,
|
|
me1200TtLoopConfigInstanceSubscriber ME1200TtLoopInstanceSubscriber,
|
|
me1200TtLoopConfigInstanceAdminState ME1200TtLoopInstanceAdminState,
|
|
me1200TtLoopConfigInstanceAction ME1200RowEditorState
|
|
}
|
|
|
|
me1200TtLoopConfigInstanceId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TT_LOOP instance ID"
|
|
::= { me1200TtLoopConfigInstanceEntry 1 }
|
|
|
|
me1200TtLoopConfigInstanceName OBJECT-TYPE
|
|
SYNTAX ME1200DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Instance name"
|
|
::= { me1200TtLoopConfigInstanceEntry 2 }
|
|
|
|
me1200TtLoopConfigInstanceType OBJECT-TYPE
|
|
SYNTAX ME1200TtLoopInstanceType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Traffic Test loop type. Currently only MAC Loop is supported"
|
|
::= { me1200TtLoopConfigInstanceEntry 3 }
|
|
|
|
me1200TtLoopConfigInstanceDirection OBJECT-TYPE
|
|
SYNTAX ME1200TtLoopInstanceDirection
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance direction. Currently only Facility Loop is supported"
|
|
::= { me1200TtLoopConfigInstanceEntry 4 }
|
|
|
|
me1200TtLoopConfigInstanceDomain OBJECT-TYPE
|
|
SYNTAX ME1200TtLoopInstanceDomain
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance domain. Currently only Port domain is supported"
|
|
::= { me1200TtLoopConfigInstanceEntry 5 }
|
|
|
|
me1200TtLoopConfigInstanceFlow OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The flow instance (VLAN - EVC)."
|
|
::= { me1200TtLoopConfigInstanceEntry 6 }
|
|
|
|
me1200TtLoopConfigInstancePort OBJECT-TYPE
|
|
SYNTAX ME1200InterfaceIndex
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance residence port."
|
|
::= { me1200TtLoopConfigInstanceEntry 7 }
|
|
|
|
me1200TtLoopConfigInstanceLevel OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance MEG level"
|
|
::= { me1200TtLoopConfigInstanceEntry 8 }
|
|
|
|
me1200TtLoopConfigInstanceSubscriber OBJECT-TYPE
|
|
SYNTAX ME1200TtLoopInstanceSubscriber
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The EVC OAM loop subscriber mode"
|
|
::= { me1200TtLoopConfigInstanceEntry 9 }
|
|
|
|
me1200TtLoopConfigInstanceAdminState OBJECT-TYPE
|
|
SYNTAX ME1200TtLoopInstanceAdminState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance Administrative state."
|
|
::= { me1200TtLoopConfigInstanceEntry 10 }
|
|
|
|
me1200TtLoopConfigInstanceAction OBJECT-TYPE
|
|
SYNTAX ME1200RowEditorState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Action"
|
|
::= { me1200TtLoopConfigInstanceEntry 100 }
|
|
|
|
me1200TtLoopConfigInstanceRowEditor OBJECT IDENTIFIER
|
|
::= { me1200TtLoopConfig 2 }
|
|
|
|
me1200TtLoopConfigInstanceRowEditorId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TT_LOOP instance ID"
|
|
::= { me1200TtLoopConfigInstanceRowEditor 1 }
|
|
|
|
me1200TtLoopConfigInstanceRowEditorName OBJECT-TYPE
|
|
SYNTAX ME1200DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Instance name"
|
|
::= { me1200TtLoopConfigInstanceRowEditor 2 }
|
|
|
|
me1200TtLoopConfigInstanceRowEditorType OBJECT-TYPE
|
|
SYNTAX ME1200TtLoopInstanceType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Traffic Test loop type. Currently only MAC Loop is supported"
|
|
::= { me1200TtLoopConfigInstanceRowEditor 3 }
|
|
|
|
me1200TtLoopConfigInstanceRowEditorDirection OBJECT-TYPE
|
|
SYNTAX ME1200TtLoopInstanceDirection
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance direction. Currently only Facility Loop is supported"
|
|
::= { me1200TtLoopConfigInstanceRowEditor 4 }
|
|
|
|
me1200TtLoopConfigInstanceRowEditorDomain OBJECT-TYPE
|
|
SYNTAX ME1200TtLoopInstanceDomain
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance domain. Currently only Port domain is supported"
|
|
::= { me1200TtLoopConfigInstanceRowEditor 5 }
|
|
|
|
me1200TtLoopConfigInstanceRowEditorFlow OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The flow instance (VLAN - EVC)."
|
|
::= { me1200TtLoopConfigInstanceRowEditor 6 }
|
|
|
|
me1200TtLoopConfigInstanceRowEditorPort OBJECT-TYPE
|
|
SYNTAX ME1200InterfaceIndex
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance residence port."
|
|
::= { me1200TtLoopConfigInstanceRowEditor 7 }
|
|
|
|
me1200TtLoopConfigInstanceRowEditorLevel OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance MEG level"
|
|
::= { me1200TtLoopConfigInstanceRowEditor 8 }
|
|
|
|
me1200TtLoopConfigInstanceRowEditorSubscriber OBJECT-TYPE
|
|
SYNTAX ME1200TtLoopInstanceSubscriber
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The EVC OAM loop subscriber mode"
|
|
::= { me1200TtLoopConfigInstanceRowEditor 9 }
|
|
|
|
me1200TtLoopConfigInstanceRowEditorAdminState OBJECT-TYPE
|
|
SYNTAX ME1200TtLoopInstanceAdminState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance Administrative state."
|
|
::= { me1200TtLoopConfigInstanceRowEditor 10 }
|
|
|
|
me1200TtLoopConfigInstanceRowEditorAction OBJECT-TYPE
|
|
SYNTAX ME1200RowEditorState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Action"
|
|
::= { me1200TtLoopConfigInstanceRowEditor 100 }
|
|
|
|
me1200TtLoopLlConfigInstanceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200TtLoopLlConfigInstanceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table enables the user to configure the MEF 46 Latching Loopback
|
|
parameters for the created TT-LOOP instances. Entries in the table will
|
|
be automatically created or deleted when the corresponding entry in the
|
|
ttLoopConfigInstanceTable is created or deleted, but the content will
|
|
only be valid if the Latching Loopback function has been enabled for
|
|
the TT-LOOP instance."
|
|
::= { me1200TtLoopConfig 3 }
|
|
|
|
me1200TtLoopLlConfigInstanceEntry OBJECT-TYPE
|
|
SYNTAX ME1200TtLoopLlConfigInstanceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry contains all configurable Latching Loopback parameters for a
|
|
TT-LOOP instance."
|
|
INDEX { me1200TtLoopLlConfigInstanceId }
|
|
::= { me1200TtLoopLlConfigInstanceTable 1 }
|
|
|
|
ME1200TtLoopLlConfigInstanceEntry ::= SEQUENCE {
|
|
me1200TtLoopLlConfigInstanceId Integer32,
|
|
me1200TtLoopLlConfigInstanceEnable TruthValue,
|
|
me1200TtLoopLlConfigInstanceMepId Unsigned32,
|
|
me1200TtLoopLlConfigInstanceSourceMac MacAddress
|
|
}
|
|
|
|
me1200TtLoopLlConfigInstanceId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TT_LOOP instance ID"
|
|
::= { me1200TtLoopLlConfigInstanceEntry 1 }
|
|
|
|
me1200TtLoopLlConfigInstanceEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to 'true' enables the use of Latching Loopback
|
|
functionality for an existing TT-LOOP instance. If the value is 'false'
|
|
the instance works as a static TT-LOOP instance."
|
|
::= { me1200TtLoopLlConfigInstanceEntry 2 }
|
|
|
|
me1200TtLoopLlConfigInstanceMepId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MEP ID associated with the TT-LOOP instance. If the Latching
|
|
Loopback function is enabled using the 'Enable' object above then this
|
|
value must be a valid MEP ID value. The MEP may however not be created
|
|
yet."
|
|
::= { me1200TtLoopLlConfigInstanceEntry 3 }
|
|
|
|
me1200TtLoopLlConfigInstanceSourceMac OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source MAC address from which to accept Latching Loopback Message
|
|
(LLM) PDUs for this instance."
|
|
::= { me1200TtLoopLlConfigInstanceEntry 4 }
|
|
|
|
me1200TtLoopStatus OBJECT IDENTIFIER
|
|
::= { me1200TtLoopMibObjects 3 }
|
|
|
|
me1200TtLoopStatusInstanceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200TtLoopStatusInstanceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a table of created instance status"
|
|
::= { me1200TtLoopStatus 1 }
|
|
|
|
me1200TtLoopStatusInstanceEntry OBJECT-TYPE
|
|
SYNTAX ME1200TtLoopStatusInstanceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a created instance status"
|
|
INDEX { me1200TtLoopStatusInstanceId }
|
|
::= { me1200TtLoopStatusInstanceTable 1 }
|
|
|
|
ME1200TtLoopStatusInstanceEntry ::= SEQUENCE {
|
|
me1200TtLoopStatusInstanceId Integer32,
|
|
me1200TtLoopStatusInstanceOperState ME1200TtLoopInstanceOperState
|
|
}
|
|
|
|
me1200TtLoopStatusInstanceId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TT_LOOP instance ID"
|
|
::= { me1200TtLoopStatusInstanceEntry 1 }
|
|
|
|
me1200TtLoopStatusInstanceOperState OBJECT-TYPE
|
|
SYNTAX ME1200TtLoopInstanceOperState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance Operational state."
|
|
::= { me1200TtLoopStatusInstanceEntry 2 }
|
|
|
|
me1200TtLoopLlStatusInstanceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200TtLoopLlStatusInstanceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table enables the user to view the MEF 46 Latching Loopback status
|
|
for the created TT-LOOP instances. Entries in the table will be
|
|
automatically created or deleted when the corresponding entry in the
|
|
ttLoopConfigInstanceTable is created or deleted."
|
|
::= { me1200TtLoopStatus 2 }
|
|
|
|
me1200TtLoopLlStatusInstanceEntry OBJECT-TYPE
|
|
SYNTAX ME1200TtLoopLlStatusInstanceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry contains all status Latching Loopback parameters for a
|
|
TT-LOOP instance."
|
|
INDEX { me1200TtLoopLlStatusInstanceId }
|
|
::= { me1200TtLoopLlStatusInstanceTable 1 }
|
|
|
|
ME1200TtLoopLlStatusInstanceEntry ::= SEQUENCE {
|
|
me1200TtLoopLlStatusInstanceId Integer32,
|
|
me1200TtLoopLlStatusInstanceRemainExpTimer Unsigned32
|
|
}
|
|
|
|
me1200TtLoopLlStatusInstanceId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TT_LOOP instance ID"
|
|
::= { me1200TtLoopLlStatusInstanceEntry 1 }
|
|
|
|
me1200TtLoopLlStatusInstanceRemainExpTimer OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining expiry timer in seconds. This value is non-zero if the
|
|
operational state of the Latching Loopback instance is 'up' (aka.
|
|
'Active' in MEF 46 terms). It will be zero if the operational state is
|
|
not 'up' or if Latching Loopback has not been enabled for the TT-LOOP
|
|
instance."
|
|
::= { me1200TtLoopLlStatusInstanceEntry 2 }
|
|
|
|
me1200TtLoopMibConformance OBJECT IDENTIFIER
|
|
::= { me1200TtLoopMib 3 }
|
|
|
|
me1200TtLoopMibCompliances OBJECT IDENTIFIER
|
|
::= { me1200TtLoopMibConformance 1 }
|
|
|
|
me1200TtLoopMibGroups OBJECT IDENTIFIER
|
|
::= { me1200TtLoopMibConformance 2 }
|
|
|
|
me1200TtLoopCapabilitiesInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200TtLoopCapabilitiesInstanceMax,
|
|
me1200TtLoopCapabilitiesNameMax }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200TtLoopMibGroups 1 }
|
|
|
|
me1200TtLoopConfigInstanceTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200TtLoopConfigInstanceName, me1200TtLoopConfigInstanceType,
|
|
me1200TtLoopConfigInstanceDirection,
|
|
me1200TtLoopConfigInstanceDomain, me1200TtLoopConfigInstanceFlow,
|
|
me1200TtLoopConfigInstancePort, me1200TtLoopConfigInstanceLevel,
|
|
me1200TtLoopConfigInstanceSubscriber,
|
|
me1200TtLoopConfigInstanceAdminState,
|
|
me1200TtLoopConfigInstanceAction }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200TtLoopMibGroups 2 }
|
|
|
|
me1200TtLoopConfigInstanceRowEditorInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200TtLoopConfigInstanceRowEditorId,
|
|
me1200TtLoopConfigInstanceRowEditorName,
|
|
me1200TtLoopConfigInstanceRowEditorType,
|
|
me1200TtLoopConfigInstanceRowEditorDirection,
|
|
me1200TtLoopConfigInstanceRowEditorDomain,
|
|
me1200TtLoopConfigInstanceRowEditorFlow,
|
|
me1200TtLoopConfigInstanceRowEditorPort,
|
|
me1200TtLoopConfigInstanceRowEditorLevel,
|
|
me1200TtLoopConfigInstanceRowEditorSubscriber,
|
|
me1200TtLoopConfigInstanceRowEditorAdminState,
|
|
me1200TtLoopConfigInstanceRowEditorAction }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200TtLoopMibGroups 3 }
|
|
|
|
me1200TtLoopLlConfigInstanceTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200TtLoopLlConfigInstanceEnable,
|
|
me1200TtLoopLlConfigInstanceMepId,
|
|
me1200TtLoopLlConfigInstanceSourceMac }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200TtLoopMibGroups 4 }
|
|
|
|
me1200TtLoopStatusInstanceTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200TtLoopStatusInstanceOperState }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200TtLoopMibGroups 5 }
|
|
|
|
me1200TtLoopLlStatusInstanceTableInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200TtLoopLlStatusInstanceRemainExpTimer }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200TtLoopMibGroups 6 }
|
|
|
|
me1200TtLoopMibCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for the implementation."
|
|
|
|
MODULE -- this module
|
|
|
|
MANDATORY-GROUPS { me1200TtLoopCapabilitiesInfoGroup,
|
|
me1200TtLoopConfigInstanceTableInfoGroup,
|
|
me1200TtLoopConfigInstanceRowEditorInfoGroup,
|
|
me1200TtLoopLlConfigInstanceTableInfoGroup,
|
|
me1200TtLoopStatusInstanceTableInfoGroup,
|
|
me1200TtLoopLlStatusInstanceTableInfoGroup }
|
|
|
|
::= { me1200TtLoopMibCompliances 1 }
|
|
|
|
END
|