-- ***************************************************************** -- TT-LOOP-MIB: ME1200 Private MIB -- -- -- **************************************************************** ME1200-TT-LOOP-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI TEXTUAL-CONVENTION FROM SNMPv2-TC me1200SwitchMgmt FROM CISCOME1200-MIB ME1200DisplayString FROM ME1200-TC ME1200InterfaceIndex FROM ME1200-TC ME1200RowEditorState FROM ME1200-TC Integer32 FROM SNMPv2-SMI Unsigned32 FROM SNMPv2-SMI MacAddress FROM SNMPv2-TC TruthValue FROM SNMPv2-TC ; me1200TtLoopMib MODULE-IDENTITY LAST-UPDATED "201405190000Z" ORGANIZATION "Cisco Systems, Inc" CONTACT-INFO "Cisco Systems, Inc Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-me1200@cisco.com" DESCRIPTION "This is a private Traffic Test Loop MIB that can be used for RFC2544 and Y.1564 (remote end) testing" REVISION "201612070000Z" DESCRIPTION "Support for Latching Loopback function: Added me1200TtLoopLlConfigInstanceTable." REVISION "201405190000Z" DESCRIPTION "Initial version" ::= { me1200SwitchMgmt 128 } ME1200TtLoopInstanceAdminState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The instance Administrative State." SYNTAX INTEGER { adminDisabled(0), adminEnabled(1) } ME1200TtLoopInstanceDirection ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The instance direction." SYNTAX INTEGER { facility(0), terminal(1) } ME1200TtLoopInstanceDomain ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The instance domain." SYNTAX INTEGER { port(0), evc(1), vlan(2) } ME1200TtLoopInstanceOperState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The instance Operational State." SYNTAX INTEGER { operDown(0), operUp(1), operInact(2) } ME1200TtLoopInstanceSubscriber ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The instance subscriber mode." SYNTAX INTEGER { none(0), all(1), test(2) } ME1200TtLoopInstanceType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The instance type." SYNTAX INTEGER { macLoop(0), oamLoop(1) } me1200TtLoopMibObjects OBJECT IDENTIFIER ::= { me1200TtLoopMib 1 } me1200TtLoopCapabilities OBJECT IDENTIFIER ::= { me1200TtLoopMibObjects 1 } me1200TtLoopCapabilitiesInstanceMax OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max number of TT_LOOP instance" ::= { me1200TtLoopCapabilities 1 } me1200TtLoopCapabilitiesNameMax OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max length of instance name" ::= { me1200TtLoopCapabilities 2 } me1200TtLoopConfig OBJECT IDENTIFIER ::= { me1200TtLoopMibObjects 2 } me1200TtLoopConfigInstanceTable OBJECT-TYPE SYNTAX SEQUENCE OF ME1200TtLoopConfigInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a table of created instance configuration parameters" ::= { me1200TtLoopConfig 1 } me1200TtLoopConfigInstanceEntry OBJECT-TYPE SYNTAX ME1200TtLoopConfigInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a created instance configuration parameters. Not all parameters can be changed" INDEX { me1200TtLoopConfigInstanceId } ::= { me1200TtLoopConfigInstanceTable 1 } ME1200TtLoopConfigInstanceEntry ::= SEQUENCE { me1200TtLoopConfigInstanceId Integer32, me1200TtLoopConfigInstanceName ME1200DisplayString, me1200TtLoopConfigInstanceType ME1200TtLoopInstanceType, me1200TtLoopConfigInstanceDirection ME1200TtLoopInstanceDirection, me1200TtLoopConfigInstanceDomain ME1200TtLoopInstanceDomain, me1200TtLoopConfigInstanceFlow Unsigned32, me1200TtLoopConfigInstancePort ME1200InterfaceIndex, me1200TtLoopConfigInstanceLevel Unsigned32, me1200TtLoopConfigInstanceSubscriber ME1200TtLoopInstanceSubscriber, me1200TtLoopConfigInstanceAdminState ME1200TtLoopInstanceAdminState, me1200TtLoopConfigInstanceAction ME1200RowEditorState } me1200TtLoopConfigInstanceId OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The TT_LOOP instance ID" ::= { me1200TtLoopConfigInstanceEntry 1 } me1200TtLoopConfigInstanceName OBJECT-TYPE SYNTAX ME1200DisplayString (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Instance name" ::= { me1200TtLoopConfigInstanceEntry 2 } me1200TtLoopConfigInstanceType OBJECT-TYPE SYNTAX ME1200TtLoopInstanceType MAX-ACCESS read-write STATUS current DESCRIPTION "The Traffic Test loop type. Currently only MAC Loop is supported" ::= { me1200TtLoopConfigInstanceEntry 3 } me1200TtLoopConfigInstanceDirection OBJECT-TYPE SYNTAX ME1200TtLoopInstanceDirection MAX-ACCESS read-write STATUS current DESCRIPTION "The instance direction. Currently only Facility Loop is supported" ::= { me1200TtLoopConfigInstanceEntry 4 } me1200TtLoopConfigInstanceDomain OBJECT-TYPE SYNTAX ME1200TtLoopInstanceDomain MAX-ACCESS read-write STATUS current DESCRIPTION "The instance domain. Currently only Port domain is supported" ::= { me1200TtLoopConfigInstanceEntry 5 } me1200TtLoopConfigInstanceFlow OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The flow instance (VLAN - EVC)." ::= { me1200TtLoopConfigInstanceEntry 6 } me1200TtLoopConfigInstancePort OBJECT-TYPE SYNTAX ME1200InterfaceIndex MAX-ACCESS read-write STATUS current DESCRIPTION "The instance residence port." ::= { me1200TtLoopConfigInstanceEntry 7 } me1200TtLoopConfigInstanceLevel OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The instance MEG level" ::= { me1200TtLoopConfigInstanceEntry 8 } me1200TtLoopConfigInstanceSubscriber OBJECT-TYPE SYNTAX ME1200TtLoopInstanceSubscriber MAX-ACCESS read-write STATUS current DESCRIPTION "The EVC OAM loop subscriber mode" ::= { me1200TtLoopConfigInstanceEntry 9 } me1200TtLoopConfigInstanceAdminState OBJECT-TYPE SYNTAX ME1200TtLoopInstanceAdminState MAX-ACCESS read-write STATUS current DESCRIPTION "The instance Administrative state." ::= { me1200TtLoopConfigInstanceEntry 10 } me1200TtLoopConfigInstanceAction OBJECT-TYPE SYNTAX ME1200RowEditorState MAX-ACCESS read-write STATUS current DESCRIPTION "Action" ::= { me1200TtLoopConfigInstanceEntry 100 } me1200TtLoopConfigInstanceRowEditor OBJECT IDENTIFIER ::= { me1200TtLoopConfig 2 } me1200TtLoopConfigInstanceRowEditorId OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The TT_LOOP instance ID" ::= { me1200TtLoopConfigInstanceRowEditor 1 } me1200TtLoopConfigInstanceRowEditorName OBJECT-TYPE SYNTAX ME1200DisplayString (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Instance name" ::= { me1200TtLoopConfigInstanceRowEditor 2 } me1200TtLoopConfigInstanceRowEditorType OBJECT-TYPE SYNTAX ME1200TtLoopInstanceType MAX-ACCESS read-write STATUS current DESCRIPTION "The Traffic Test loop type. Currently only MAC Loop is supported" ::= { me1200TtLoopConfigInstanceRowEditor 3 } me1200TtLoopConfigInstanceRowEditorDirection OBJECT-TYPE SYNTAX ME1200TtLoopInstanceDirection MAX-ACCESS read-write STATUS current DESCRIPTION "The instance direction. Currently only Facility Loop is supported" ::= { me1200TtLoopConfigInstanceRowEditor 4 } me1200TtLoopConfigInstanceRowEditorDomain OBJECT-TYPE SYNTAX ME1200TtLoopInstanceDomain MAX-ACCESS read-write STATUS current DESCRIPTION "The instance domain. Currently only Port domain is supported" ::= { me1200TtLoopConfigInstanceRowEditor 5 } me1200TtLoopConfigInstanceRowEditorFlow OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The flow instance (VLAN - EVC)." ::= { me1200TtLoopConfigInstanceRowEditor 6 } me1200TtLoopConfigInstanceRowEditorPort OBJECT-TYPE SYNTAX ME1200InterfaceIndex MAX-ACCESS read-write STATUS current DESCRIPTION "The instance residence port." ::= { me1200TtLoopConfigInstanceRowEditor 7 } me1200TtLoopConfigInstanceRowEditorLevel OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The instance MEG level" ::= { me1200TtLoopConfigInstanceRowEditor 8 } me1200TtLoopConfigInstanceRowEditorSubscriber OBJECT-TYPE SYNTAX ME1200TtLoopInstanceSubscriber MAX-ACCESS read-write STATUS current DESCRIPTION "The EVC OAM loop subscriber mode" ::= { me1200TtLoopConfigInstanceRowEditor 9 } me1200TtLoopConfigInstanceRowEditorAdminState OBJECT-TYPE SYNTAX ME1200TtLoopInstanceAdminState MAX-ACCESS read-write STATUS current DESCRIPTION "The instance Administrative state." ::= { me1200TtLoopConfigInstanceRowEditor 10 } me1200TtLoopConfigInstanceRowEditorAction OBJECT-TYPE SYNTAX ME1200RowEditorState MAX-ACCESS read-write STATUS current DESCRIPTION "Action" ::= { me1200TtLoopConfigInstanceRowEditor 100 } me1200TtLoopLlConfigInstanceTable OBJECT-TYPE SYNTAX SEQUENCE OF ME1200TtLoopLlConfigInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table enables the user to configure the MEF 46 Latching Loopback parameters for the created TT-LOOP instances. Entries in the table will be automatically created or deleted when the corresponding entry in the ttLoopConfigInstanceTable is created or deleted, but the content will only be valid if the Latching Loopback function has been enabled for the TT-LOOP instance." ::= { me1200TtLoopConfig 3 } me1200TtLoopLlConfigInstanceEntry OBJECT-TYPE SYNTAX ME1200TtLoopLlConfigInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entry contains all configurable Latching Loopback parameters for a TT-LOOP instance." INDEX { me1200TtLoopLlConfigInstanceId } ::= { me1200TtLoopLlConfigInstanceTable 1 } ME1200TtLoopLlConfigInstanceEntry ::= SEQUENCE { me1200TtLoopLlConfigInstanceId Integer32, me1200TtLoopLlConfigInstanceEnable TruthValue, me1200TtLoopLlConfigInstanceMepId Unsigned32, me1200TtLoopLlConfigInstanceSourceMac MacAddress } me1200TtLoopLlConfigInstanceId OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The TT_LOOP instance ID" ::= { me1200TtLoopLlConfigInstanceEntry 1 } me1200TtLoopLlConfigInstanceEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to 'true' enables the use of Latching Loopback functionality for an existing TT-LOOP instance. If the value is 'false' the instance works as a static TT-LOOP instance." ::= { me1200TtLoopLlConfigInstanceEntry 2 } me1200TtLoopLlConfigInstanceMepId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The MEP ID associated with the TT-LOOP instance. If the Latching Loopback function is enabled using the 'Enable' object above then this value must be a valid MEP ID value. The MEP may however not be created yet." ::= { me1200TtLoopLlConfigInstanceEntry 3 } me1200TtLoopLlConfigInstanceSourceMac OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The source MAC address from which to accept Latching Loopback Message (LLM) PDUs for this instance." ::= { me1200TtLoopLlConfigInstanceEntry 4 } me1200TtLoopStatus OBJECT IDENTIFIER ::= { me1200TtLoopMibObjects 3 } me1200TtLoopStatusInstanceTable OBJECT-TYPE SYNTAX SEQUENCE OF ME1200TtLoopStatusInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a table of created instance status" ::= { me1200TtLoopStatus 1 } me1200TtLoopStatusInstanceEntry OBJECT-TYPE SYNTAX ME1200TtLoopStatusInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a created instance status" INDEX { me1200TtLoopStatusInstanceId } ::= { me1200TtLoopStatusInstanceTable 1 } ME1200TtLoopStatusInstanceEntry ::= SEQUENCE { me1200TtLoopStatusInstanceId Integer32, me1200TtLoopStatusInstanceOperState ME1200TtLoopInstanceOperState } me1200TtLoopStatusInstanceId OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The TT_LOOP instance ID" ::= { me1200TtLoopStatusInstanceEntry 1 } me1200TtLoopStatusInstanceOperState OBJECT-TYPE SYNTAX ME1200TtLoopInstanceOperState MAX-ACCESS read-only STATUS current DESCRIPTION "The instance Operational state." ::= { me1200TtLoopStatusInstanceEntry 2 } me1200TtLoopLlStatusInstanceTable OBJECT-TYPE SYNTAX SEQUENCE OF ME1200TtLoopLlStatusInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table enables the user to view the MEF 46 Latching Loopback status for the created TT-LOOP instances. Entries in the table will be automatically created or deleted when the corresponding entry in the ttLoopConfigInstanceTable is created or deleted." ::= { me1200TtLoopStatus 2 } me1200TtLoopLlStatusInstanceEntry OBJECT-TYPE SYNTAX ME1200TtLoopLlStatusInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entry contains all status Latching Loopback parameters for a TT-LOOP instance." INDEX { me1200TtLoopLlStatusInstanceId } ::= { me1200TtLoopLlStatusInstanceTable 1 } ME1200TtLoopLlStatusInstanceEntry ::= SEQUENCE { me1200TtLoopLlStatusInstanceId Integer32, me1200TtLoopLlStatusInstanceRemainExpTimer Unsigned32 } me1200TtLoopLlStatusInstanceId OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The TT_LOOP instance ID" ::= { me1200TtLoopLlStatusInstanceEntry 1 } me1200TtLoopLlStatusInstanceRemainExpTimer OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The remaining expiry timer in seconds. This value is non-zero if the operational state of the Latching Loopback instance is 'up' (aka. 'Active' in MEF 46 terms). It will be zero if the operational state is not 'up' or if Latching Loopback has not been enabled for the TT-LOOP instance." ::= { me1200TtLoopLlStatusInstanceEntry 2 } me1200TtLoopMibConformance OBJECT IDENTIFIER ::= { me1200TtLoopMib 3 } me1200TtLoopMibCompliances OBJECT IDENTIFIER ::= { me1200TtLoopMibConformance 1 } me1200TtLoopMibGroups OBJECT IDENTIFIER ::= { me1200TtLoopMibConformance 2 } me1200TtLoopCapabilitiesInfoGroup OBJECT-GROUP OBJECTS { me1200TtLoopCapabilitiesInstanceMax, me1200TtLoopCapabilitiesNameMax } STATUS current DESCRIPTION "A collection of objects suitable for bulk operations." ::= { me1200TtLoopMibGroups 1 } me1200TtLoopConfigInstanceTableInfoGroup OBJECT-GROUP OBJECTS { me1200TtLoopConfigInstanceName, me1200TtLoopConfigInstanceType, me1200TtLoopConfigInstanceDirection, me1200TtLoopConfigInstanceDomain, me1200TtLoopConfigInstanceFlow, me1200TtLoopConfigInstancePort, me1200TtLoopConfigInstanceLevel, me1200TtLoopConfigInstanceSubscriber, me1200TtLoopConfigInstanceAdminState, me1200TtLoopConfigInstanceAction } STATUS current DESCRIPTION "A collection of objects suitable for bulk operations." ::= { me1200TtLoopMibGroups 2 } me1200TtLoopConfigInstanceRowEditorInfoGroup OBJECT-GROUP OBJECTS { me1200TtLoopConfigInstanceRowEditorId, me1200TtLoopConfigInstanceRowEditorName, me1200TtLoopConfigInstanceRowEditorType, me1200TtLoopConfigInstanceRowEditorDirection, me1200TtLoopConfigInstanceRowEditorDomain, me1200TtLoopConfigInstanceRowEditorFlow, me1200TtLoopConfigInstanceRowEditorPort, me1200TtLoopConfigInstanceRowEditorLevel, me1200TtLoopConfigInstanceRowEditorSubscriber, me1200TtLoopConfigInstanceRowEditorAdminState, me1200TtLoopConfigInstanceRowEditorAction } STATUS current DESCRIPTION "A collection of objects suitable for bulk operations." ::= { me1200TtLoopMibGroups 3 } me1200TtLoopLlConfigInstanceTableInfoGroup OBJECT-GROUP OBJECTS { me1200TtLoopLlConfigInstanceEnable, me1200TtLoopLlConfigInstanceMepId, me1200TtLoopLlConfigInstanceSourceMac } STATUS current DESCRIPTION "A collection of objects suitable for bulk operations." ::= { me1200TtLoopMibGroups 4 } me1200TtLoopStatusInstanceTableInfoGroup OBJECT-GROUP OBJECTS { me1200TtLoopStatusInstanceOperState } STATUS current DESCRIPTION "A collection of objects suitable for bulk operations." ::= { me1200TtLoopMibGroups 5 } me1200TtLoopLlStatusInstanceTableInfoGroup OBJECT-GROUP OBJECTS { me1200TtLoopLlStatusInstanceRemainExpTimer } STATUS current DESCRIPTION "A collection of objects suitable for bulk operations." ::= { me1200TtLoopMibGroups 6 } me1200TtLoopMibCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for the implementation." MODULE -- this module MANDATORY-GROUPS { me1200TtLoopCapabilitiesInfoGroup, me1200TtLoopConfigInstanceTableInfoGroup, me1200TtLoopConfigInstanceRowEditorInfoGroup, me1200TtLoopLlConfigInstanceTableInfoGroup, me1200TtLoopStatusInstanceTableInfoGroup, me1200TtLoopLlStatusInstanceTableInfoGroup } ::= { me1200TtLoopMibCompliances 1 } END