Observium_CE/mibs/cisco/ME1200-SYNCE-MIB

741 lines
26 KiB
Plaintext

-- *****************************************************************
-- SYNCE-MIB: ME1200 Private MIB
--
-- ****************************************************************
ME1200-SYNCE-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
FROM SNMPv2-SMI
TEXTUAL-CONVENTION
FROM SNMPv2-TC
me1200SwitchMgmt
FROM CISCOME1200-MIB
ME1200InterfaceIndex FROM ME1200-TC
ME1200Unsigned8 FROM ME1200-TC
Integer32 FROM SNMPv2-SMI
Unsigned32 FROM SNMPv2-SMI
TruthValue FROM SNMPv2-TC
;
me1200SynceMib MODULE-IDENTITY
LAST-UPDATED "201605090000Z"
ORGANIZATION
"Cisco Systems, Inc"
CONTACT-INFO
"Cisco Systems, Inc
Customer Service
Postal: 170 W Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553-NETS
E-mail: cs-me1200@cisco.com"
DESCRIPTION
"Private SyncE MIB."
REVISION "201605090000Z"
DESCRIPTION
"Added SyncE clock selector state change notification"
REVISION "201406240000Z"
DESCRIPTION
"Initial version"
::= { me1200SwitchMgmt 42 }
ME1200synceAnegMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"-"
SYNTAX INTEGER { none(0), preferedSlave(1), preferedMaster(2), forcedSlave(3) }
ME1200synceEecOption ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"-"
SYNTAX INTEGER { eecOption1(0), eecOption2(1) }
ME1200synceFrequency ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"-"
SYNTAX INTEGER { disabled(0), freq1544kHz(1), freq2048kHz(2), freq10MHz(3), freqMax(4) }
ME1200syncePtsfState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"-"
SYNTAX INTEGER { none(0), unusable(1), lossSync(2), lossAnnounce(3) }
ME1200synceQualityLevel ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"-"
SYNTAX INTEGER { qlNone(0), qlPrc(1), qlSsua(2), qlSsub(3), qlEec2(4), qlEec1(5), qlDnu(6), qlInv(7), qlFail(8), qlLink(9) }
ME1200synceSelectionMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"-"
SYNTAX INTEGER { manual(0), manualToSelected(1), autoNonrevertive(2), autoRevertive(3), forcedHoldover(4), forcedFreeRun(5) }
ME1200synceSelectorState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"-"
SYNTAX INTEGER { locked(0), holdover(1), freerun(2), ptp(3), refFailed(4), acquiring(5) }
me1200SynceMibObjects OBJECT IDENTIFIER
::= { me1200SynceMib 1 }
me1200SynceCapabilities OBJECT IDENTIFIER
::= { me1200SynceMibObjects 1 }
me1200SynceCapabilitiesGlobal OBJECT IDENTIFIER
::= { me1200SynceCapabilities 1 }
me1200SynceCapabilitiesGlobalSourceCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of SyncE sources supported by the device."
::= { me1200SynceCapabilitiesGlobal 1 }
me1200SynceConfig OBJECT IDENTIFIER
::= { me1200SynceMibObjects 2 }
me1200SynceConfigGlobal OBJECT IDENTIFIER
::= { me1200SynceConfig 1 }
me1200SynceConfigGlobalClockSelectionMode OBJECT IDENTIFIER
::= { me1200SynceConfigGlobal 1 }
me1200SynceConfigGlobalClockSelectionModeSelectionMode OBJECT-TYPE
SYNTAX ME1200synceSelectionMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The selection mode."
::= { me1200SynceConfigGlobalClockSelectionMode 1 }
me1200SynceConfigGlobalClockSelectionModeSource OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Nominated source for manuel selection mode."
::= { me1200SynceConfigGlobalClockSelectionMode 2 }
me1200SynceConfigGlobalClockSelectionModeWtrTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"WTR timer value in minutes. Range is 0 to 12 minutes where 0 means that
the timer is disabled."
::= { me1200SynceConfigGlobalClockSelectionMode 3 }
me1200SynceConfigGlobalClockSelectionModeSsmHoldover OBJECT-TYPE
SYNTAX ME1200synceQualityLevel
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tx overwrite SSM used when clock controller is hold over."
::= { me1200SynceConfigGlobalClockSelectionMode 4 }
me1200SynceConfigGlobalClockSelectionModeSsmFreerun OBJECT-TYPE
SYNTAX ME1200synceQualityLevel
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tx overwrite SSM used when clock controller is free run."
::= { me1200SynceConfigGlobalClockSelectionMode 5 }
me1200SynceConfigGlobalClockSelectionModeEecOption OBJECT-TYPE
SYNTAX ME1200synceEecOption
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Synchronous Ethernet Equipment Clock option."
::= { me1200SynceConfigGlobalClockSelectionMode 6 }
me1200SynceConfigGlobalStationClocks OBJECT IDENTIFIER
::= { me1200SynceConfigGlobal 2 }
me1200SynceConfigGlobalStationClocksStationClkOut OBJECT-TYPE
SYNTAX ME1200synceFrequency
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Station clock output frequency setting."
::= { me1200SynceConfigGlobalStationClocks 1 }
me1200SynceConfigGlobalStationClocksStationClkIn OBJECT-TYPE
SYNTAX ME1200synceFrequency
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Station clock input frequency setting."
::= { me1200SynceConfigGlobalStationClocks 2 }
me1200SynceConfigSources OBJECT IDENTIFIER
::= { me1200SynceConfig 2 }
me1200SynceConfigSourcesClockSourceNominationTable OBJECT-TYPE
SYNTAX SEQUENCE OF ME1200SynceConfigSourcesClockSourceNominationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the SyncE source nomination configuration."
::= { me1200SynceConfigSources 1 }
me1200SynceConfigSourcesClockSourceNominationEntry OBJECT-TYPE
SYNTAX ME1200SynceConfigSourcesClockSourceNominationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The sourceId index must be a value from 0 up to the number of sources
minus one."
INDEX { me1200SynceConfigSourcesClockSourceNominationSourceId }
::= { me1200SynceConfigSourcesClockSourceNominationTable 1 }
ME1200SynceConfigSourcesClockSourceNominationEntry ::= SEQUENCE {
me1200SynceConfigSourcesClockSourceNominationSourceId Integer32,
me1200SynceConfigSourcesClockSourceNominationNominated TruthValue,
me1200SynceConfigSourcesClockSourceNominationNetworkPort ME1200InterfaceIndex,
me1200SynceConfigSourcesClockSourceNominationClkInPort ME1200Unsigned8,
me1200SynceConfigSourcesClockSourceNominationPriority Unsigned32,
me1200SynceConfigSourcesClockSourceNominationAnegMode ME1200synceAnegMode,
me1200SynceConfigSourcesClockSourceNominationSsmOverwrite ME1200synceQualityLevel,
me1200SynceConfigSourcesClockSourceNominationHoldoffTime Unsigned32
}
me1200SynceConfigSourcesClockSourceNominationSourceId OBJECT-TYPE
SYNTAX Integer32 (0..32767)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"-"
::= { me1200SynceConfigSourcesClockSourceNominationEntry 1 }
me1200SynceConfigSourcesClockSourceNominationNominated OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates if source is nominated."
::= { me1200SynceConfigSourcesClockSourceNominationEntry 2 }
me1200SynceConfigSourcesClockSourceNominationNetworkPort OBJECT-TYPE
SYNTAX ME1200InterfaceIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Interface index of the norminated source."
::= { me1200SynceConfigSourcesClockSourceNominationEntry 3 }
me1200SynceConfigSourcesClockSourceNominationClkInPort OBJECT-TYPE
SYNTAX ME1200Unsigned8
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock input of the norminated source."
::= { me1200SynceConfigSourcesClockSourceNominationEntry 4 }
me1200SynceConfigSourcesClockSourceNominationPriority OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Priority of the nominated source."
::= { me1200SynceConfigSourcesClockSourceNominationEntry 5 }
me1200SynceConfigSourcesClockSourceNominationAnegMode OBJECT-TYPE
SYNTAX ME1200synceAnegMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Autonogotiation mode auto-master-slave."
::= { me1200SynceConfigSourcesClockSourceNominationEntry 6 }
me1200SynceConfigSourcesClockSourceNominationSsmOverwrite OBJECT-TYPE
SYNTAX ME1200synceQualityLevel
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SSM overwrite quality."
::= { me1200SynceConfigSourcesClockSourceNominationEntry 7 }
me1200SynceConfigSourcesClockSourceNominationHoldoffTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hold Off timer value in 100ms (3 - 18). Zero means no hold off."
::= { me1200SynceConfigSourcesClockSourceNominationEntry 8 }
me1200SynceConfigPorts OBJECT IDENTIFIER
::= { me1200SynceConfig 3 }
me1200SynceConfigPortsPortConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ME1200SynceConfigPortsPortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the SyncE port configuration."
::= { me1200SynceConfigPorts 1 }
me1200SynceConfigPortsPortConfigEntry OBJECT-TYPE
SYNTAX ME1200SynceConfigPortsPortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The portId index must be a value from 0 up to the number of ports minus
one."
INDEX { me1200SynceConfigPortsPortConfigPortId }
::= { me1200SynceConfigPortsPortConfigTable 1 }
ME1200SynceConfigPortsPortConfigEntry ::= SEQUENCE {
me1200SynceConfigPortsPortConfigPortId ME1200InterfaceIndex,
me1200SynceConfigPortsPortConfigSsmEnabled TruthValue
}
me1200SynceConfigPortsPortConfigPortId OBJECT-TYPE
SYNTAX ME1200InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"-"
::= { me1200SynceConfigPortsPortConfigEntry 1 }
me1200SynceConfigPortsPortConfigSsmEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Quality level via SSM enabled."
::= { me1200SynceConfigPortsPortConfigEntry 2 }
me1200SynceStatus OBJECT IDENTIFIER
::= { me1200SynceMibObjects 3 }
me1200SynceStatusGlobal OBJECT IDENTIFIER
::= { me1200SynceStatus 1 }
me1200SynceStatusGlobalClockSelectionMode OBJECT IDENTIFIER
::= { me1200SynceStatusGlobal 1 }
me1200SynceStatusGlobalClockSelectionModeClockInput OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The clock source locked to when clock selector is in locked state."
::= { me1200SynceStatusGlobalClockSelectionMode 1 }
me1200SynceStatusGlobalClockSelectionModeSelectorState OBJECT-TYPE
SYNTAX ME1200synceSelectorState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is indicating the state of the clock selector."
::= { me1200SynceStatusGlobalClockSelectionMode 2 }
me1200SynceStatusGlobalClockSelectionModeLosx OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LOSX"
::= { me1200SynceStatusGlobalClockSelectionMode 3 }
me1200SynceStatusGlobalClockSelectionModeLol OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clock selector has raised the Los Of Lock alarm."
::= { me1200SynceStatusGlobalClockSelectionMode 4 }
me1200SynceStatusGlobalClockSelectionModeDhold OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clock selector has not yet calculated the holdover frequency offset to
local oscillator."
::= { me1200SynceStatusGlobalClockSelectionMode 5 }
me1200SynceStatusSources OBJECT IDENTIFIER
::= { me1200SynceStatus 2 }
me1200SynceStatusSourcesClockSourceNominationTable OBJECT-TYPE
SYNTAX SEQUENCE OF ME1200SynceStatusSourcesClockSourceNominationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the clock source nomination status."
::= { me1200SynceStatusSources 1 }
me1200SynceStatusSourcesClockSourceNominationEntry OBJECT-TYPE
SYNTAX ME1200SynceStatusSourcesClockSourceNominationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The sourceId index must be a value must be a value from 0 up to the
number of sources minus one."
INDEX { me1200SynceStatusSourcesClockSourceNominationSourceId }
::= { me1200SynceStatusSourcesClockSourceNominationTable 1 }
ME1200SynceStatusSourcesClockSourceNominationEntry ::= SEQUENCE {
me1200SynceStatusSourcesClockSourceNominationSourceId Integer32,
me1200SynceStatusSourcesClockSourceNominationLocs TruthValue,
me1200SynceStatusSourcesClockSourceNominationFos TruthValue,
me1200SynceStatusSourcesClockSourceNominationSsm TruthValue,
me1200SynceStatusSourcesClockSourceNominationWtr TruthValue
}
me1200SynceStatusSourcesClockSourceNominationSourceId OBJECT-TYPE
SYNTAX Integer32 (0..32767)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"-"
::= { me1200SynceStatusSourcesClockSourceNominationEntry 1 }
me1200SynceStatusSourcesClockSourceNominationLocs OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LOCS"
::= { me1200SynceStatusSourcesClockSourceNominationEntry 2 }
me1200SynceStatusSourcesClockSourceNominationFos OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"FOS"
::= { me1200SynceStatusSourcesClockSourceNominationEntry 3 }
me1200SynceStatusSourcesClockSourceNominationSsm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SSM"
::= { me1200SynceStatusSourcesClockSourceNominationEntry 4 }
me1200SynceStatusSourcesClockSourceNominationWtr OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"WTR"
::= { me1200SynceStatusSourcesClockSourceNominationEntry 5 }
me1200SynceStatusPorts OBJECT IDENTIFIER
::= { me1200SynceStatus 3 }
me1200SynceStatusPortsPortStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF ME1200SynceStatusPortsPortStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the port status."
::= { me1200SynceStatusPorts 1 }
me1200SynceStatusPortsPortStatusEntry OBJECT-TYPE
SYNTAX ME1200SynceStatusPortsPortStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The portId index must be a value must be a value from 0 up to the
number of ports minus one."
INDEX { me1200SynceStatusPortsPortStatusPortId }
::= { me1200SynceStatusPortsPortStatusTable 1 }
ME1200SynceStatusPortsPortStatusEntry ::= SEQUENCE {
me1200SynceStatusPortsPortStatusPortId ME1200InterfaceIndex,
me1200SynceStatusPortsPortStatusSsmRx ME1200synceQualityLevel,
me1200SynceStatusPortsPortStatusSsmTx ME1200synceQualityLevel,
me1200SynceStatusPortsPortStatusMaster TruthValue
}
me1200SynceStatusPortsPortStatusPortId OBJECT-TYPE
SYNTAX ME1200InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"-"
::= { me1200SynceStatusPortsPortStatusEntry 1 }
me1200SynceStatusPortsPortStatusSsmRx OBJECT-TYPE
SYNTAX ME1200synceQualityLevel
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Monitoring of the received SSM QL on this port."
::= { me1200SynceStatusPortsPortStatusEntry 2 }
me1200SynceStatusPortsPortStatusSsmTx OBJECT-TYPE
SYNTAX ME1200synceQualityLevel
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Monitoring of the transmitted SSM QL on this port."
::= { me1200SynceStatusPortsPortStatusEntry 3 }
me1200SynceStatusPortsPortStatusMaster OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If PHY is in 1000BaseT Mode then this is monitoring the master/slave
mode."
::= { me1200SynceStatusPortsPortStatusEntry 4 }
me1200SynceStatusPtp OBJECT IDENTIFIER
::= { me1200SynceStatus 4 }
me1200SynceStatusPtpPortStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF ME1200SynceStatusPtpPortStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the PTP port status."
::= { me1200SynceStatusPtp 1 }
me1200SynceStatusPtpPortStatusEntry OBJECT-TYPE
SYNTAX ME1200SynceStatusPtpPortStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The sourceId index must be a value must be a value from 0 up to the
number of PTP sources minus one."
INDEX { me1200SynceStatusPtpPortStatusSourceId }
::= { me1200SynceStatusPtpPortStatusTable 1 }
ME1200SynceStatusPtpPortStatusEntry ::= SEQUENCE {
me1200SynceStatusPtpPortStatusSourceId Integer32,
me1200SynceStatusPtpPortStatusSsmRx ME1200synceQualityLevel,
me1200SynceStatusPtpPortStatusPtsf ME1200syncePtsfState
}
me1200SynceStatusPtpPortStatusSourceId OBJECT-TYPE
SYNTAX Integer32 (0..32767)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"-"
::= { me1200SynceStatusPtpPortStatusEntry 1 }
me1200SynceStatusPtpPortStatusSsmRx OBJECT-TYPE
SYNTAX ME1200synceQualityLevel
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Monitoring of the received SSM QL on this port."
::= { me1200SynceStatusPtpPortStatusEntry 2 }
me1200SynceStatusPtpPortStatusPtsf OBJECT-TYPE
SYNTAX ME1200syncePtsfState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTSF status for PTP source."
::= { me1200SynceStatusPtpPortStatusEntry 3 }
me1200SynceControl OBJECT IDENTIFIER
::= { me1200SynceMibObjects 4 }
me1200SynceControlSources OBJECT IDENTIFIER
::= { me1200SynceControl 1 }
me1200SynceControlSourcesClockSourceTable OBJECT-TYPE
SYNTAX SEQUENCE OF ME1200SynceControlSourcesClockSourceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the SyncE sources control structure."
::= { me1200SynceControlSources 1 }
me1200SynceControlSourcesClockSourceEntry OBJECT-TYPE
SYNTAX ME1200SynceControlSourcesClockSourceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The sourceId index must be a value must be a value from 0 up to the
number of sources minus one."
INDEX { me1200SynceControlSourcesClockSourceSourceId }
::= { me1200SynceControlSourcesClockSourceTable 1 }
ME1200SynceControlSourcesClockSourceEntry ::= SEQUENCE {
me1200SynceControlSourcesClockSourceSourceId Integer32,
me1200SynceControlSourcesClockSourceClearWtr ME1200Unsigned8
}
me1200SynceControlSourcesClockSourceSourceId OBJECT-TYPE
SYNTAX Integer32 (0..32767)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"-"
::= { me1200SynceControlSourcesClockSourceEntry 1 }
me1200SynceControlSourcesClockSourceClearWtr OBJECT-TYPE
SYNTAX ME1200Unsigned8
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"-"
::= { me1200SynceControlSourcesClockSourceEntry 2 }
me1200SynceNotificationPrefix OBJECT IDENTIFIER
::= { me1200SynceMibObjects 5 }
me1200SynceNotification OBJECT IDENTIFIER
::= { me1200SynceNotificationPrefix 0 }
me1200SynceNotificationClockSelectorStateChange NOTIFICATION-TYPE
OBJECTS { me1200SynceStatusGlobalClockSelectionModeClockInput,
me1200SynceStatusGlobalClockSelectionModeSelectorState }
STATUS current
DESCRIPTION
"Notification is sent when the clock selector state is changed."
::= { me1200SynceNotification 1 }
me1200SynceMibConformance OBJECT IDENTIFIER
::= { me1200SynceMib 2 }
me1200SynceMibCompliances OBJECT IDENTIFIER
::= { me1200SynceMibConformance 1 }
me1200SynceMibGroups OBJECT IDENTIFIER
::= { me1200SynceMibConformance 2 }
me1200SynceCapabilitiesGlobalInfoGroup OBJECT-GROUP
OBJECTS { me1200SynceCapabilitiesGlobalSourceCount }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { me1200SynceMibGroups 1 }
me1200SynceConfigGlobalClockSelectionModeInfoGroup OBJECT-GROUP
OBJECTS { me1200SynceConfigGlobalClockSelectionModeSelectionMode,
me1200SynceConfigGlobalClockSelectionModeSource,
me1200SynceConfigGlobalClockSelectionModeWtrTime,
me1200SynceConfigGlobalClockSelectionModeSsmHoldover,
me1200SynceConfigGlobalClockSelectionModeSsmFreerun,
me1200SynceConfigGlobalClockSelectionModeEecOption }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { me1200SynceMibGroups 2 }
me1200SynceConfigGlobalStationClocksInfoGroup OBJECT-GROUP
OBJECTS { me1200SynceConfigGlobalStationClocksStationClkOut,
me1200SynceConfigGlobalStationClocksStationClkIn }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { me1200SynceMibGroups 3 }
me1200SynceConfigSourcesClockSourceNominationInfoGroup OBJECT-GROUP
OBJECTS { me1200SynceConfigSourcesClockSourceNominationNominated,
me1200SynceConfigSourcesClockSourceNominationNetworkPort,
me1200SynceConfigSourcesClockSourceNominationClkInPort,
me1200SynceConfigSourcesClockSourceNominationPriority,
me1200SynceConfigSourcesClockSourceNominationAnegMode,
me1200SynceConfigSourcesClockSourceNominationSsmOverwrite,
me1200SynceConfigSourcesClockSourceNominationHoldoffTime }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { me1200SynceMibGroups 4 }
me1200SynceConfigPortsPortConfigInfoGroup OBJECT-GROUP
OBJECTS { me1200SynceConfigPortsPortConfigSsmEnabled }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { me1200SynceMibGroups 5 }
me1200SynceStatusGlobalClockSelectionModeInfoGroup OBJECT-GROUP
OBJECTS { me1200SynceStatusGlobalClockSelectionModeClockInput,
me1200SynceStatusGlobalClockSelectionModeSelectorState,
me1200SynceStatusGlobalClockSelectionModeLosx,
me1200SynceStatusGlobalClockSelectionModeLol,
me1200SynceStatusGlobalClockSelectionModeDhold }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { me1200SynceMibGroups 6 }
me1200SynceStatusSourcesClockSourceNominationInfoGroup OBJECT-GROUP
OBJECTS { me1200SynceStatusSourcesClockSourceNominationLocs,
me1200SynceStatusSourcesClockSourceNominationFos,
me1200SynceStatusSourcesClockSourceNominationSsm,
me1200SynceStatusSourcesClockSourceNominationWtr }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { me1200SynceMibGroups 7 }
me1200SynceStatusPortsPortStatusInfoGroup OBJECT-GROUP
OBJECTS { me1200SynceStatusPortsPortStatusSsmRx,
me1200SynceStatusPortsPortStatusSsmTx,
me1200SynceStatusPortsPortStatusMaster }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { me1200SynceMibGroups 8 }
me1200SynceStatusPtpPortStatusInfoGroup OBJECT-GROUP
OBJECTS { me1200SynceStatusPtpPortStatusSsmRx,
me1200SynceStatusPtpPortStatusPtsf }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { me1200SynceMibGroups 9 }
me1200SynceControlSourcesClockSourceInfoGroup OBJECT-GROUP
OBJECTS { me1200SynceControlSourcesClockSourceClearWtr }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { me1200SynceMibGroups 10 }
me1200SynceNotificationInfoGroup NOTIFICATION-GROUP
NOTIFICATIONS { me1200SynceNotificationClockSelectorStateChange }
STATUS current
DESCRIPTION
"A collection of objects suitable for bulk operations."
::= { me1200SynceMibGroups 11 }
me1200SynceMibCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the implementation."
MODULE -- this module
MANDATORY-GROUPS { me1200SynceCapabilitiesGlobalInfoGroup,
me1200SynceConfigGlobalClockSelectionModeInfoGroup,
me1200SynceConfigGlobalStationClocksInfoGroup,
me1200SynceConfigSourcesClockSourceNominationInfoGroup,
me1200SynceConfigPortsPortConfigInfoGroup,
me1200SynceStatusGlobalClockSelectionModeInfoGroup,
me1200SynceStatusSourcesClockSourceNominationInfoGroup,
me1200SynceStatusPortsPortStatusInfoGroup,
me1200SynceStatusPtpPortStatusInfoGroup,
me1200SynceControlSourcesClockSourceInfoGroup,
me1200SynceNotificationInfoGroup }
::= { me1200SynceMibCompliances 1 }
END