-- ***************************************************************** -- SYNCE-MIB: ME1200 Private MIB -- -- **************************************************************** ME1200-SYNCE-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE FROM SNMPv2-SMI TEXTUAL-CONVENTION FROM SNMPv2-TC me1200SwitchMgmt FROM CISCOME1200-MIB ME1200InterfaceIndex FROM ME1200-TC ME1200Unsigned8 FROM ME1200-TC Integer32 FROM SNMPv2-SMI Unsigned32 FROM SNMPv2-SMI TruthValue FROM SNMPv2-TC ; me1200SynceMib MODULE-IDENTITY LAST-UPDATED "201605090000Z" ORGANIZATION "Cisco Systems, Inc" CONTACT-INFO "Cisco Systems, Inc Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-me1200@cisco.com" DESCRIPTION "Private SyncE MIB." REVISION "201605090000Z" DESCRIPTION "Added SyncE clock selector state change notification" REVISION "201406240000Z" DESCRIPTION "Initial version" ::= { me1200SwitchMgmt 42 } ME1200synceAnegMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "-" SYNTAX INTEGER { none(0), preferedSlave(1), preferedMaster(2), forcedSlave(3) } ME1200synceEecOption ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "-" SYNTAX INTEGER { eecOption1(0), eecOption2(1) } ME1200synceFrequency ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "-" SYNTAX INTEGER { disabled(0), freq1544kHz(1), freq2048kHz(2), freq10MHz(3), freqMax(4) } ME1200syncePtsfState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "-" SYNTAX INTEGER { none(0), unusable(1), lossSync(2), lossAnnounce(3) } ME1200synceQualityLevel ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "-" SYNTAX INTEGER { qlNone(0), qlPrc(1), qlSsua(2), qlSsub(3), qlEec2(4), qlEec1(5), qlDnu(6), qlInv(7), qlFail(8), qlLink(9) } ME1200synceSelectionMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "-" SYNTAX INTEGER { manual(0), manualToSelected(1), autoNonrevertive(2), autoRevertive(3), forcedHoldover(4), forcedFreeRun(5) } ME1200synceSelectorState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "-" SYNTAX INTEGER { locked(0), holdover(1), freerun(2), ptp(3), refFailed(4), acquiring(5) } me1200SynceMibObjects OBJECT IDENTIFIER ::= { me1200SynceMib 1 } me1200SynceCapabilities OBJECT IDENTIFIER ::= { me1200SynceMibObjects 1 } me1200SynceCapabilitiesGlobal OBJECT IDENTIFIER ::= { me1200SynceCapabilities 1 } me1200SynceCapabilitiesGlobalSourceCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SyncE sources supported by the device." ::= { me1200SynceCapabilitiesGlobal 1 } me1200SynceConfig OBJECT IDENTIFIER ::= { me1200SynceMibObjects 2 } me1200SynceConfigGlobal OBJECT IDENTIFIER ::= { me1200SynceConfig 1 } me1200SynceConfigGlobalClockSelectionMode OBJECT IDENTIFIER ::= { me1200SynceConfigGlobal 1 } me1200SynceConfigGlobalClockSelectionModeSelectionMode OBJECT-TYPE SYNTAX ME1200synceSelectionMode MAX-ACCESS read-write STATUS current DESCRIPTION "The selection mode." ::= { me1200SynceConfigGlobalClockSelectionMode 1 } me1200SynceConfigGlobalClockSelectionModeSource OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Nominated source for manuel selection mode." ::= { me1200SynceConfigGlobalClockSelectionMode 2 } me1200SynceConfigGlobalClockSelectionModeWtrTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "WTR timer value in minutes. Range is 0 to 12 minutes where 0 means that the timer is disabled." ::= { me1200SynceConfigGlobalClockSelectionMode 3 } me1200SynceConfigGlobalClockSelectionModeSsmHoldover OBJECT-TYPE SYNTAX ME1200synceQualityLevel MAX-ACCESS read-write STATUS current DESCRIPTION "Tx overwrite SSM used when clock controller is hold over." ::= { me1200SynceConfigGlobalClockSelectionMode 4 } me1200SynceConfigGlobalClockSelectionModeSsmFreerun OBJECT-TYPE SYNTAX ME1200synceQualityLevel MAX-ACCESS read-write STATUS current DESCRIPTION "Tx overwrite SSM used when clock controller is free run." ::= { me1200SynceConfigGlobalClockSelectionMode 5 } me1200SynceConfigGlobalClockSelectionModeEecOption OBJECT-TYPE SYNTAX ME1200synceEecOption MAX-ACCESS read-write STATUS current DESCRIPTION "Synchronous Ethernet Equipment Clock option." ::= { me1200SynceConfigGlobalClockSelectionMode 6 } me1200SynceConfigGlobalStationClocks OBJECT IDENTIFIER ::= { me1200SynceConfigGlobal 2 } me1200SynceConfigGlobalStationClocksStationClkOut OBJECT-TYPE SYNTAX ME1200synceFrequency MAX-ACCESS read-write STATUS current DESCRIPTION "Station clock output frequency setting." ::= { me1200SynceConfigGlobalStationClocks 1 } me1200SynceConfigGlobalStationClocksStationClkIn OBJECT-TYPE SYNTAX ME1200synceFrequency MAX-ACCESS read-write STATUS current DESCRIPTION "Station clock input frequency setting." ::= { me1200SynceConfigGlobalStationClocks 2 } me1200SynceConfigSources OBJECT IDENTIFIER ::= { me1200SynceConfig 2 } me1200SynceConfigSourcesClockSourceNominationTable OBJECT-TYPE SYNTAX SEQUENCE OF ME1200SynceConfigSourcesClockSourceNominationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the SyncE source nomination configuration." ::= { me1200SynceConfigSources 1 } me1200SynceConfigSourcesClockSourceNominationEntry OBJECT-TYPE SYNTAX ME1200SynceConfigSourcesClockSourceNominationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The sourceId index must be a value from 0 up to the number of sources minus one." INDEX { me1200SynceConfigSourcesClockSourceNominationSourceId } ::= { me1200SynceConfigSourcesClockSourceNominationTable 1 } ME1200SynceConfigSourcesClockSourceNominationEntry ::= SEQUENCE { me1200SynceConfigSourcesClockSourceNominationSourceId Integer32, me1200SynceConfigSourcesClockSourceNominationNominated TruthValue, me1200SynceConfigSourcesClockSourceNominationNetworkPort ME1200InterfaceIndex, me1200SynceConfigSourcesClockSourceNominationClkInPort ME1200Unsigned8, me1200SynceConfigSourcesClockSourceNominationPriority Unsigned32, me1200SynceConfigSourcesClockSourceNominationAnegMode ME1200synceAnegMode, me1200SynceConfigSourcesClockSourceNominationSsmOverwrite ME1200synceQualityLevel, me1200SynceConfigSourcesClockSourceNominationHoldoffTime Unsigned32 } me1200SynceConfigSourcesClockSourceNominationSourceId OBJECT-TYPE SYNTAX Integer32 (0..32767) MAX-ACCESS not-accessible STATUS current DESCRIPTION "-" ::= { me1200SynceConfigSourcesClockSourceNominationEntry 1 } me1200SynceConfigSourcesClockSourceNominationNominated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if source is nominated." ::= { me1200SynceConfigSourcesClockSourceNominationEntry 2 } me1200SynceConfigSourcesClockSourceNominationNetworkPort OBJECT-TYPE SYNTAX ME1200InterfaceIndex MAX-ACCESS read-write STATUS current DESCRIPTION "Interface index of the norminated source." ::= { me1200SynceConfigSourcesClockSourceNominationEntry 3 } me1200SynceConfigSourcesClockSourceNominationClkInPort OBJECT-TYPE SYNTAX ME1200Unsigned8 MAX-ACCESS read-write STATUS current DESCRIPTION "Clock input of the norminated source." ::= { me1200SynceConfigSourcesClockSourceNominationEntry 4 } me1200SynceConfigSourcesClockSourceNominationPriority OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Priority of the nominated source." ::= { me1200SynceConfigSourcesClockSourceNominationEntry 5 } me1200SynceConfigSourcesClockSourceNominationAnegMode OBJECT-TYPE SYNTAX ME1200synceAnegMode MAX-ACCESS read-write STATUS current DESCRIPTION "Autonogotiation mode auto-master-slave." ::= { me1200SynceConfigSourcesClockSourceNominationEntry 6 } me1200SynceConfigSourcesClockSourceNominationSsmOverwrite OBJECT-TYPE SYNTAX ME1200synceQualityLevel MAX-ACCESS read-write STATUS current DESCRIPTION "SSM overwrite quality." ::= { me1200SynceConfigSourcesClockSourceNominationEntry 7 } me1200SynceConfigSourcesClockSourceNominationHoldoffTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Hold Off timer value in 100ms (3 - 18). Zero means no hold off." ::= { me1200SynceConfigSourcesClockSourceNominationEntry 8 } me1200SynceConfigPorts OBJECT IDENTIFIER ::= { me1200SynceConfig 3 } me1200SynceConfigPortsPortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF ME1200SynceConfigPortsPortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the SyncE port configuration." ::= { me1200SynceConfigPorts 1 } me1200SynceConfigPortsPortConfigEntry OBJECT-TYPE SYNTAX ME1200SynceConfigPortsPortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The portId index must be a value from 0 up to the number of ports minus one." INDEX { me1200SynceConfigPortsPortConfigPortId } ::= { me1200SynceConfigPortsPortConfigTable 1 } ME1200SynceConfigPortsPortConfigEntry ::= SEQUENCE { me1200SynceConfigPortsPortConfigPortId ME1200InterfaceIndex, me1200SynceConfigPortsPortConfigSsmEnabled TruthValue } me1200SynceConfigPortsPortConfigPortId OBJECT-TYPE SYNTAX ME1200InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "-" ::= { me1200SynceConfigPortsPortConfigEntry 1 } me1200SynceConfigPortsPortConfigSsmEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Quality level via SSM enabled." ::= { me1200SynceConfigPortsPortConfigEntry 2 } me1200SynceStatus OBJECT IDENTIFIER ::= { me1200SynceMibObjects 3 } me1200SynceStatusGlobal OBJECT IDENTIFIER ::= { me1200SynceStatus 1 } me1200SynceStatusGlobalClockSelectionMode OBJECT IDENTIFIER ::= { me1200SynceStatusGlobal 1 } me1200SynceStatusGlobalClockSelectionModeClockInput OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The clock source locked to when clock selector is in locked state." ::= { me1200SynceStatusGlobalClockSelectionMode 1 } me1200SynceStatusGlobalClockSelectionModeSelectorState OBJECT-TYPE SYNTAX ME1200synceSelectorState MAX-ACCESS read-only STATUS current DESCRIPTION "This is indicating the state of the clock selector." ::= { me1200SynceStatusGlobalClockSelectionMode 2 } me1200SynceStatusGlobalClockSelectionModeLosx OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "LOSX" ::= { me1200SynceStatusGlobalClockSelectionMode 3 } me1200SynceStatusGlobalClockSelectionModeLol OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Clock selector has raised the Los Of Lock alarm." ::= { me1200SynceStatusGlobalClockSelectionMode 4 } me1200SynceStatusGlobalClockSelectionModeDhold OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Clock selector has not yet calculated the holdover frequency offset to local oscillator." ::= { me1200SynceStatusGlobalClockSelectionMode 5 } me1200SynceStatusSources OBJECT IDENTIFIER ::= { me1200SynceStatus 2 } me1200SynceStatusSourcesClockSourceNominationTable OBJECT-TYPE SYNTAX SEQUENCE OF ME1200SynceStatusSourcesClockSourceNominationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the clock source nomination status." ::= { me1200SynceStatusSources 1 } me1200SynceStatusSourcesClockSourceNominationEntry OBJECT-TYPE SYNTAX ME1200SynceStatusSourcesClockSourceNominationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The sourceId index must be a value must be a value from 0 up to the number of sources minus one." INDEX { me1200SynceStatusSourcesClockSourceNominationSourceId } ::= { me1200SynceStatusSourcesClockSourceNominationTable 1 } ME1200SynceStatusSourcesClockSourceNominationEntry ::= SEQUENCE { me1200SynceStatusSourcesClockSourceNominationSourceId Integer32, me1200SynceStatusSourcesClockSourceNominationLocs TruthValue, me1200SynceStatusSourcesClockSourceNominationFos TruthValue, me1200SynceStatusSourcesClockSourceNominationSsm TruthValue, me1200SynceStatusSourcesClockSourceNominationWtr TruthValue } me1200SynceStatusSourcesClockSourceNominationSourceId OBJECT-TYPE SYNTAX Integer32 (0..32767) MAX-ACCESS not-accessible STATUS current DESCRIPTION "-" ::= { me1200SynceStatusSourcesClockSourceNominationEntry 1 } me1200SynceStatusSourcesClockSourceNominationLocs OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "LOCS" ::= { me1200SynceStatusSourcesClockSourceNominationEntry 2 } me1200SynceStatusSourcesClockSourceNominationFos OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "FOS" ::= { me1200SynceStatusSourcesClockSourceNominationEntry 3 } me1200SynceStatusSourcesClockSourceNominationSsm OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "SSM" ::= { me1200SynceStatusSourcesClockSourceNominationEntry 4 } me1200SynceStatusSourcesClockSourceNominationWtr OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "WTR" ::= { me1200SynceStatusSourcesClockSourceNominationEntry 5 } me1200SynceStatusPorts OBJECT IDENTIFIER ::= { me1200SynceStatus 3 } me1200SynceStatusPortsPortStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ME1200SynceStatusPortsPortStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the port status." ::= { me1200SynceStatusPorts 1 } me1200SynceStatusPortsPortStatusEntry OBJECT-TYPE SYNTAX ME1200SynceStatusPortsPortStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The portId index must be a value must be a value from 0 up to the number of ports minus one." INDEX { me1200SynceStatusPortsPortStatusPortId } ::= { me1200SynceStatusPortsPortStatusTable 1 } ME1200SynceStatusPortsPortStatusEntry ::= SEQUENCE { me1200SynceStatusPortsPortStatusPortId ME1200InterfaceIndex, me1200SynceStatusPortsPortStatusSsmRx ME1200synceQualityLevel, me1200SynceStatusPortsPortStatusSsmTx ME1200synceQualityLevel, me1200SynceStatusPortsPortStatusMaster TruthValue } me1200SynceStatusPortsPortStatusPortId OBJECT-TYPE SYNTAX ME1200InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "-" ::= { me1200SynceStatusPortsPortStatusEntry 1 } me1200SynceStatusPortsPortStatusSsmRx OBJECT-TYPE SYNTAX ME1200synceQualityLevel MAX-ACCESS read-only STATUS current DESCRIPTION "Monitoring of the received SSM QL on this port." ::= { me1200SynceStatusPortsPortStatusEntry 2 } me1200SynceStatusPortsPortStatusSsmTx OBJECT-TYPE SYNTAX ME1200synceQualityLevel MAX-ACCESS read-only STATUS current DESCRIPTION "Monitoring of the transmitted SSM QL on this port." ::= { me1200SynceStatusPortsPortStatusEntry 3 } me1200SynceStatusPortsPortStatusMaster OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "If PHY is in 1000BaseT Mode then this is monitoring the master/slave mode." ::= { me1200SynceStatusPortsPortStatusEntry 4 } me1200SynceStatusPtp OBJECT IDENTIFIER ::= { me1200SynceStatus 4 } me1200SynceStatusPtpPortStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ME1200SynceStatusPtpPortStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the PTP port status." ::= { me1200SynceStatusPtp 1 } me1200SynceStatusPtpPortStatusEntry OBJECT-TYPE SYNTAX ME1200SynceStatusPtpPortStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The sourceId index must be a value must be a value from 0 up to the number of PTP sources minus one." INDEX { me1200SynceStatusPtpPortStatusSourceId } ::= { me1200SynceStatusPtpPortStatusTable 1 } ME1200SynceStatusPtpPortStatusEntry ::= SEQUENCE { me1200SynceStatusPtpPortStatusSourceId Integer32, me1200SynceStatusPtpPortStatusSsmRx ME1200synceQualityLevel, me1200SynceStatusPtpPortStatusPtsf ME1200syncePtsfState } me1200SynceStatusPtpPortStatusSourceId OBJECT-TYPE SYNTAX Integer32 (0..32767) MAX-ACCESS not-accessible STATUS current DESCRIPTION "-" ::= { me1200SynceStatusPtpPortStatusEntry 1 } me1200SynceStatusPtpPortStatusSsmRx OBJECT-TYPE SYNTAX ME1200synceQualityLevel MAX-ACCESS read-only STATUS current DESCRIPTION "Monitoring of the received SSM QL on this port." ::= { me1200SynceStatusPtpPortStatusEntry 2 } me1200SynceStatusPtpPortStatusPtsf OBJECT-TYPE SYNTAX ME1200syncePtsfState MAX-ACCESS read-only STATUS current DESCRIPTION "PTSF status for PTP source." ::= { me1200SynceStatusPtpPortStatusEntry 3 } me1200SynceControl OBJECT IDENTIFIER ::= { me1200SynceMibObjects 4 } me1200SynceControlSources OBJECT IDENTIFIER ::= { me1200SynceControl 1 } me1200SynceControlSourcesClockSourceTable OBJECT-TYPE SYNTAX SEQUENCE OF ME1200SynceControlSourcesClockSourceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the SyncE sources control structure." ::= { me1200SynceControlSources 1 } me1200SynceControlSourcesClockSourceEntry OBJECT-TYPE SYNTAX ME1200SynceControlSourcesClockSourceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The sourceId index must be a value must be a value from 0 up to the number of sources minus one." INDEX { me1200SynceControlSourcesClockSourceSourceId } ::= { me1200SynceControlSourcesClockSourceTable 1 } ME1200SynceControlSourcesClockSourceEntry ::= SEQUENCE { me1200SynceControlSourcesClockSourceSourceId Integer32, me1200SynceControlSourcesClockSourceClearWtr ME1200Unsigned8 } me1200SynceControlSourcesClockSourceSourceId OBJECT-TYPE SYNTAX Integer32 (0..32767) MAX-ACCESS not-accessible STATUS current DESCRIPTION "-" ::= { me1200SynceControlSourcesClockSourceEntry 1 } me1200SynceControlSourcesClockSourceClearWtr OBJECT-TYPE SYNTAX ME1200Unsigned8 MAX-ACCESS read-write STATUS current DESCRIPTION "-" ::= { me1200SynceControlSourcesClockSourceEntry 2 } me1200SynceNotificationPrefix OBJECT IDENTIFIER ::= { me1200SynceMibObjects 5 } me1200SynceNotification OBJECT IDENTIFIER ::= { me1200SynceNotificationPrefix 0 } me1200SynceNotificationClockSelectorStateChange NOTIFICATION-TYPE OBJECTS { me1200SynceStatusGlobalClockSelectionModeClockInput, me1200SynceStatusGlobalClockSelectionModeSelectorState } STATUS current DESCRIPTION "Notification is sent when the clock selector state is changed." ::= { me1200SynceNotification 1 } me1200SynceMibConformance OBJECT IDENTIFIER ::= { me1200SynceMib 2 } me1200SynceMibCompliances OBJECT IDENTIFIER ::= { me1200SynceMibConformance 1 } me1200SynceMibGroups OBJECT IDENTIFIER ::= { me1200SynceMibConformance 2 } me1200SynceCapabilitiesGlobalInfoGroup OBJECT-GROUP OBJECTS { me1200SynceCapabilitiesGlobalSourceCount } STATUS current DESCRIPTION "A collection of objects suitable for bulk operations." ::= { me1200SynceMibGroups 1 } me1200SynceConfigGlobalClockSelectionModeInfoGroup OBJECT-GROUP OBJECTS { me1200SynceConfigGlobalClockSelectionModeSelectionMode, me1200SynceConfigGlobalClockSelectionModeSource, me1200SynceConfigGlobalClockSelectionModeWtrTime, me1200SynceConfigGlobalClockSelectionModeSsmHoldover, me1200SynceConfigGlobalClockSelectionModeSsmFreerun, me1200SynceConfigGlobalClockSelectionModeEecOption } STATUS current DESCRIPTION "A collection of objects suitable for bulk operations." ::= { me1200SynceMibGroups 2 } me1200SynceConfigGlobalStationClocksInfoGroup OBJECT-GROUP OBJECTS { me1200SynceConfigGlobalStationClocksStationClkOut, me1200SynceConfigGlobalStationClocksStationClkIn } STATUS current DESCRIPTION "A collection of objects suitable for bulk operations." ::= { me1200SynceMibGroups 3 } me1200SynceConfigSourcesClockSourceNominationInfoGroup OBJECT-GROUP OBJECTS { me1200SynceConfigSourcesClockSourceNominationNominated, me1200SynceConfigSourcesClockSourceNominationNetworkPort, me1200SynceConfigSourcesClockSourceNominationClkInPort, me1200SynceConfigSourcesClockSourceNominationPriority, me1200SynceConfigSourcesClockSourceNominationAnegMode, me1200SynceConfigSourcesClockSourceNominationSsmOverwrite, me1200SynceConfigSourcesClockSourceNominationHoldoffTime } STATUS current DESCRIPTION "A collection of objects suitable for bulk operations." ::= { me1200SynceMibGroups 4 } me1200SynceConfigPortsPortConfigInfoGroup OBJECT-GROUP OBJECTS { me1200SynceConfigPortsPortConfigSsmEnabled } STATUS current DESCRIPTION "A collection of objects suitable for bulk operations." ::= { me1200SynceMibGroups 5 } me1200SynceStatusGlobalClockSelectionModeInfoGroup OBJECT-GROUP OBJECTS { me1200SynceStatusGlobalClockSelectionModeClockInput, me1200SynceStatusGlobalClockSelectionModeSelectorState, me1200SynceStatusGlobalClockSelectionModeLosx, me1200SynceStatusGlobalClockSelectionModeLol, me1200SynceStatusGlobalClockSelectionModeDhold } STATUS current DESCRIPTION "A collection of objects suitable for bulk operations." ::= { me1200SynceMibGroups 6 } me1200SynceStatusSourcesClockSourceNominationInfoGroup OBJECT-GROUP OBJECTS { me1200SynceStatusSourcesClockSourceNominationLocs, me1200SynceStatusSourcesClockSourceNominationFos, me1200SynceStatusSourcesClockSourceNominationSsm, me1200SynceStatusSourcesClockSourceNominationWtr } STATUS current DESCRIPTION "A collection of objects suitable for bulk operations." ::= { me1200SynceMibGroups 7 } me1200SynceStatusPortsPortStatusInfoGroup OBJECT-GROUP OBJECTS { me1200SynceStatusPortsPortStatusSsmRx, me1200SynceStatusPortsPortStatusSsmTx, me1200SynceStatusPortsPortStatusMaster } STATUS current DESCRIPTION "A collection of objects suitable for bulk operations." ::= { me1200SynceMibGroups 8 } me1200SynceStatusPtpPortStatusInfoGroup OBJECT-GROUP OBJECTS { me1200SynceStatusPtpPortStatusSsmRx, me1200SynceStatusPtpPortStatusPtsf } STATUS current DESCRIPTION "A collection of objects suitable for bulk operations." ::= { me1200SynceMibGroups 9 } me1200SynceControlSourcesClockSourceInfoGroup OBJECT-GROUP OBJECTS { me1200SynceControlSourcesClockSourceClearWtr } STATUS current DESCRIPTION "A collection of objects suitable for bulk operations." ::= { me1200SynceMibGroups 10 } me1200SynceNotificationInfoGroup NOTIFICATION-GROUP NOTIFICATIONS { me1200SynceNotificationClockSelectorStateChange } STATUS current DESCRIPTION "A collection of objects suitable for bulk operations." ::= { me1200SynceMibGroups 11 } me1200SynceMibCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for the implementation." MODULE -- this module MANDATORY-GROUPS { me1200SynceCapabilitiesGlobalInfoGroup, me1200SynceConfigGlobalClockSelectionModeInfoGroup, me1200SynceConfigGlobalStationClocksInfoGroup, me1200SynceConfigSourcesClockSourceNominationInfoGroup, me1200SynceConfigPortsPortConfigInfoGroup, me1200SynceStatusGlobalClockSelectionModeInfoGroup, me1200SynceStatusSourcesClockSourceNominationInfoGroup, me1200SynceStatusPortsPortStatusInfoGroup, me1200SynceStatusPtpPortStatusInfoGroup, me1200SynceControlSourcesClockSourceInfoGroup, me1200SynceNotificationInfoGroup } ::= { me1200SynceMibCompliances 1 } END