CIENA-OME6500-OPTMONS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
InterfaceIndex
|
|
FROM IF-MIB
|
|
DisplayString
|
|
FROM RFC1213-MIB
|
|
cienaGenericMIBs
|
|
FROM CIENA-SMI
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
Integer32, MODULE-IDENTITY, OBJECT-TYPE, mib-2
|
|
FROM SNMPv2-SMI;
|
|
|
|
cienaOme6500OptmonsMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201806200000Z"
|
|
ORGANIZATION "Ciena Corporation"
|
|
CONTACT-INFO "Web URL: http://www.ciena.com"
|
|
DESCRIPTION "This modules describes Ciena's optmons object for the 6500 platform"
|
|
|
|
--Revision history
|
|
REVISION "201712130000Z"
|
|
DESCRIPTION "6500 Release 12.30"
|
|
|
|
REVISION "201804230000Z"
|
|
DESCRIPTION "cienaOme6500OptmonsIfIndex syntax change to InterfaceIndex from INTEGER in Rel 12.30."
|
|
|
|
REVISION "201806200000Z"
|
|
DESCRIPTION "Added cienaOme6500OptmonsProtNswSwStatus, cienaOme6500OptmonsProtNswSwEnd and cienaOme6500OptmonsProtNswSwReason in the cienaOme6500OptmonsTable."
|
|
|
|
::= { cienaGenericMIBs 7 }
|
|
|
|
cienaOme6500OptmonsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CienaOme6500OptmonsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "None"
|
|
::= { cienaOme6500OptmonsMIB 1 }
|
|
|
|
cienaOme6500OptmonsEntry OBJECT-TYPE
|
|
SYNTAX CienaOme6500OptmonsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entry for cienaOme6500OptmonsTable."
|
|
INDEX { cienaOme6500OptmonsIfIndex }
|
|
::= { cienaOme6500OptmonsTable 1 }
|
|
|
|
CienaOme6500OptmonsEntry ::= SEQUENCE {
|
|
cienaOme6500OptmonsIfIndex InterfaceIndex,
|
|
cienaOme6500OptmonsIfDescr DisplayString,
|
|
cienaOme6500OptmonsSst DisplayString,
|
|
cienaOme6500OptmonsPst INTEGER,
|
|
cienaOme6500OptmonsAinsTimeLeft DisplayString,
|
|
cienaOme6500OptmonsLosThres DisplayString,
|
|
cienaOme6500OptmonsPortLabel DisplayString,
|
|
cienaOme6500OptmonsAlsoDisabled DisplayString,
|
|
cienaOme6500OptmonsProtNswSwStatus DisplayString,
|
|
cienaOme6500OptmonsProtNswSwEnd DisplayString,
|
|
cienaOme6500OptmonsProtNswSwReason DisplayString
|
|
}
|
|
|
|
cienaOme6500OptmonsIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { cienaOme6500OptmonsEntry 1 }
|
|
|
|
cienaOme6500OptmonsIfDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "AID in format OPTMON-shelf-slot-port, OPTMON-shelf-slot-portSsubport, OPTMON-shelf-slotSsubslot-port, OPTMON-shelf-slotSsubslot-portSsubport, OPTMON-shelf-ALL, OPTMON-shelf-slot-ALL, OPTMON-shelf-slotSsubslot-ALL, OPTMON-shelf-slot-port-ALL, SHELF-shelf-ALL"
|
|
::= { cienaOme6500OptmonsEntry 2 }
|
|
|
|
cienaOme6500OptmonsSst OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Identify the secondary state"
|
|
::= { cienaOme6500OptmonsEntry 3 }
|
|
|
|
cienaOme6500OptmonsPst OBJECT-TYPE
|
|
SYNTAX INTEGER { is(0), oosMa(1), isAnr(2), oosAu(3), oosAuma(4), oosMaanr(5) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Identify the primary state"
|
|
::= { cienaOme6500OptmonsEntry 4 }
|
|
|
|
cienaOme6500OptmonsAinsTimeLeft OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { cienaOme6500OptmonsEntry 5 }
|
|
|
|
cienaOme6500OptmonsLosThres OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { cienaOme6500OptmonsEntry 6 }
|
|
|
|
cienaOme6500OptmonsPortLabel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { cienaOme6500OptmonsEntry 7 }
|
|
|
|
cienaOme6500OptmonsAlsoDisabled OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { cienaOme6500OptmonsEntry 8 }
|
|
|
|
cienaOme6500OptmonsProtNswSwStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { cienaOme6500OptmonsEntry 9 }
|
|
|
|
cienaOme6500OptmonsProtNswSwEnd OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { cienaOme6500OptmonsEntry 10 }
|
|
|
|
cienaOme6500OptmonsProtNswSwReason OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { cienaOme6500OptmonsEntry 11 }
|
|
|
|
cienaOme6500OptmonsProtGroupTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CienaOme6500OptmonsProtGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "None"
|
|
::= { cienaOme6500OptmonsMIB 2 }
|
|
|
|
cienaOme6500OptmonsProtGroupEntry OBJECT-TYPE
|
|
SYNTAX CienaOme6500OptmonsProtGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entry for cienaOme6500OptmonsProtGroupTable."
|
|
INDEX { cienaOme6500OptmonsProtGroupWrkgIfIndex, cienaOme6500OptmonsProtGroupProtIfIndex }
|
|
::= { cienaOme6500OptmonsProtGroupTable 1 }
|
|
|
|
CienaOme6500OptmonsProtGroupEntry ::= SEQUENCE {
|
|
cienaOme6500OptmonsProtGroupWrkgIfIndex InterfaceIndex,
|
|
cienaOme6500OptmonsProtGroupWrkgIfDescr DisplayString,
|
|
cienaOme6500OptmonsProtGroupWrkgSst DisplayString,
|
|
cienaOme6500OptmonsProtGroupProtIfIndex InterfaceIndex,
|
|
cienaOme6500OptmonsProtGroupProtIfDescr DisplayString,
|
|
cienaOme6500OptmonsProtGroupProtSst DisplayString,
|
|
cienaOme6500OptmonsProtGroupProtScheme DisplayString,
|
|
cienaOme6500OptmonsProtGroupWaitToRestore DisplayString,
|
|
cienaOme6500OptmonsProtGroupDetectGuardTime DisplayString,
|
|
cienaOme6500OptmonsProtGroupRevertive DisplayString,
|
|
cienaOme6500OptmonsProtGroupRemStandard DisplayString,
|
|
cienaOme6500OptmonsProtGroupLossPwr INTEGER,
|
|
cienaOme6500OptmonsProtGroupTtops INTEGER,
|
|
cienaOme6500OptmonsProtGroupPsDirn INTEGER
|
|
}
|
|
cienaOme6500OptmonsProtGroupWrkgIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { cienaOme6500OptmonsProtGroupEntry 1 }
|
|
|
|
cienaOme6500OptmonsProtGroupWrkgIfDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "AID in format OPTMON-shelf-slot-port, OPTMON-shelf-ALL"
|
|
::= { cienaOme6500OptmonsProtGroupEntry 2 }
|
|
|
|
cienaOme6500OptmonsProtGroupWrkgSst OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Identify the secondary state"
|
|
::= { cienaOme6500OptmonsProtGroupEntry 3 }
|
|
|
|
cienaOme6500OptmonsProtGroupProtIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { cienaOme6500OptmonsProtGroupEntry 4 }
|
|
|
|
cienaOme6500OptmonsProtGroupProtIfDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "AID in format OPTMON-shelf-slot-port, OPTMON-shelf-ALL"
|
|
::= { cienaOme6500OptmonsProtGroupEntry 5 }
|
|
|
|
cienaOme6500OptmonsProtGroupProtSst OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Identify the secondary state"
|
|
::= { cienaOme6500OptmonsProtGroupEntry 6 }
|
|
|
|
|
|
cienaOme6500OptmonsProtGroupProtScheme OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the protection scheme to be used."
|
|
::= { cienaOme6500OptmonsProtGroupEntry 7 }
|
|
|
|
cienaOme6500OptmonsProtGroupWaitToRestore OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Wait-to-restore period in minutes"
|
|
::= { cienaOme6500OptmonsProtGroupEntry 8 }
|
|
|
|
cienaOme6500OptmonsProtGroupDetectGuardTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Detection Guard DisplayString (supported on SDHJ only) "
|
|
::= { cienaOme6500OptmonsProtGroupEntry 9 }
|
|
|
|
cienaOme6500OptmonsProtGroupRevertive OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Revertive switching mode enabled?"
|
|
::= { cienaOme6500OptmonsProtGroupEntry 10 }
|
|
|
|
cienaOme6500OptmonsProtGroupRemStandard OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Standard used on the remote equipment"
|
|
::= { cienaOme6500OptmonsProtGroupEntry 11 }
|
|
|
|
cienaOme6500OptmonsProtGroupLossPwr OBJECT-TYPE
|
|
SYNTAX INTEGER { n(0), y(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Loss of Power Supply mode"
|
|
::= { cienaOme6500OptmonsProtGroupEntry 12 }
|
|
|
|
cienaOme6500OptmonsProtGroupTtops OBJECT-TYPE
|
|
SYNTAX INTEGER { n(0), y(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Transponder Triggered Switching Mode Enabled"
|
|
::= { cienaOme6500OptmonsProtGroupEntry 13 }
|
|
|
|
cienaOme6500OptmonsProtGroupPsDirn OBJECT-TYPE
|
|
SYNTAX INTEGER { uni(0), bi(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Protection Switch Direction.Default=UNI."
|
|
::= { cienaOme6500OptmonsProtGroupEntry 14 }
|
|
|
|
|
|
END -- End module
|