Observium_CE/mibs/ciena/CIENA-OME6500-OPTMONS-MIB

271 lines
8.6 KiB
Plaintext

CIENA-OME6500-OPTMONS-MIB DEFINITIONS ::= BEGIN
IMPORTS
InterfaceIndex
FROM IF-MIB
DisplayString
FROM RFC1213-MIB
cienaGenericMIBs
FROM CIENA-SMI
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
Integer32, MODULE-IDENTITY, OBJECT-TYPE, mib-2
FROM SNMPv2-SMI;
cienaOme6500OptmonsMIB MODULE-IDENTITY
LAST-UPDATED "201806200000Z"
ORGANIZATION "Ciena Corporation"
CONTACT-INFO "Web URL: http://www.ciena.com"
DESCRIPTION "This modules describes Ciena's optmons object for the 6500 platform"
--Revision history
REVISION "201712130000Z"
DESCRIPTION "6500 Release 12.30"
REVISION "201804230000Z"
DESCRIPTION "cienaOme6500OptmonsIfIndex syntax change to InterfaceIndex from INTEGER in Rel 12.30."
REVISION "201806200000Z"
DESCRIPTION "Added cienaOme6500OptmonsProtNswSwStatus, cienaOme6500OptmonsProtNswSwEnd and cienaOme6500OptmonsProtNswSwReason in the cienaOme6500OptmonsTable."
::= { cienaGenericMIBs 7 }
cienaOme6500OptmonsTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaOme6500OptmonsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "None"
::= { cienaOme6500OptmonsMIB 1 }
cienaOme6500OptmonsEntry OBJECT-TYPE
SYNTAX CienaOme6500OptmonsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry for cienaOme6500OptmonsTable."
INDEX { cienaOme6500OptmonsIfIndex }
::= { cienaOme6500OptmonsTable 1 }
CienaOme6500OptmonsEntry ::= SEQUENCE {
cienaOme6500OptmonsIfIndex InterfaceIndex,
cienaOme6500OptmonsIfDescr DisplayString,
cienaOme6500OptmonsSst DisplayString,
cienaOme6500OptmonsPst INTEGER,
cienaOme6500OptmonsAinsTimeLeft DisplayString,
cienaOme6500OptmonsLosThres DisplayString,
cienaOme6500OptmonsPortLabel DisplayString,
cienaOme6500OptmonsAlsoDisabled DisplayString,
cienaOme6500OptmonsProtNswSwStatus DisplayString,
cienaOme6500OptmonsProtNswSwEnd DisplayString,
cienaOme6500OptmonsProtNswSwReason DisplayString
}
cienaOme6500OptmonsIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { cienaOme6500OptmonsEntry 1 }
cienaOme6500OptmonsIfDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "AID in format OPTMON-shelf-slot-port, OPTMON-shelf-slot-portSsubport, OPTMON-shelf-slotSsubslot-port, OPTMON-shelf-slotSsubslot-portSsubport, OPTMON-shelf-ALL, OPTMON-shelf-slot-ALL, OPTMON-shelf-slotSsubslot-ALL, OPTMON-shelf-slot-port-ALL, SHELF-shelf-ALL"
::= { cienaOme6500OptmonsEntry 2 }
cienaOme6500OptmonsSst OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Identify the secondary state"
::= { cienaOme6500OptmonsEntry 3 }
cienaOme6500OptmonsPst OBJECT-TYPE
SYNTAX INTEGER { is(0), oosMa(1), isAnr(2), oosAu(3), oosAuma(4), oosMaanr(5) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Identify the primary state"
::= { cienaOme6500OptmonsEntry 4 }
cienaOme6500OptmonsAinsTimeLeft OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { cienaOme6500OptmonsEntry 5 }
cienaOme6500OptmonsLosThres OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { cienaOme6500OptmonsEntry 6 }
cienaOme6500OptmonsPortLabel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { cienaOme6500OptmonsEntry 7 }
cienaOme6500OptmonsAlsoDisabled OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { cienaOme6500OptmonsEntry 8 }
cienaOme6500OptmonsProtNswSwStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { cienaOme6500OptmonsEntry 9 }
cienaOme6500OptmonsProtNswSwEnd OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { cienaOme6500OptmonsEntry 10 }
cienaOme6500OptmonsProtNswSwReason OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { cienaOme6500OptmonsEntry 11 }
cienaOme6500OptmonsProtGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF CienaOme6500OptmonsProtGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "None"
::= { cienaOme6500OptmonsMIB 2 }
cienaOme6500OptmonsProtGroupEntry OBJECT-TYPE
SYNTAX CienaOme6500OptmonsProtGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry for cienaOme6500OptmonsProtGroupTable."
INDEX { cienaOme6500OptmonsProtGroupWrkgIfIndex, cienaOme6500OptmonsProtGroupProtIfIndex }
::= { cienaOme6500OptmonsProtGroupTable 1 }
CienaOme6500OptmonsProtGroupEntry ::= SEQUENCE {
cienaOme6500OptmonsProtGroupWrkgIfIndex InterfaceIndex,
cienaOme6500OptmonsProtGroupWrkgIfDescr DisplayString,
cienaOme6500OptmonsProtGroupWrkgSst DisplayString,
cienaOme6500OptmonsProtGroupProtIfIndex InterfaceIndex,
cienaOme6500OptmonsProtGroupProtIfDescr DisplayString,
cienaOme6500OptmonsProtGroupProtSst DisplayString,
cienaOme6500OptmonsProtGroupProtScheme DisplayString,
cienaOme6500OptmonsProtGroupWaitToRestore DisplayString,
cienaOme6500OptmonsProtGroupDetectGuardTime DisplayString,
cienaOme6500OptmonsProtGroupRevertive DisplayString,
cienaOme6500OptmonsProtGroupRemStandard DisplayString,
cienaOme6500OptmonsProtGroupLossPwr INTEGER,
cienaOme6500OptmonsProtGroupTtops INTEGER,
cienaOme6500OptmonsProtGroupPsDirn INTEGER
}
cienaOme6500OptmonsProtGroupWrkgIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { cienaOme6500OptmonsProtGroupEntry 1 }
cienaOme6500OptmonsProtGroupWrkgIfDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "AID in format OPTMON-shelf-slot-port, OPTMON-shelf-ALL"
::= { cienaOme6500OptmonsProtGroupEntry 2 }
cienaOme6500OptmonsProtGroupWrkgSst OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Identify the secondary state"
::= { cienaOme6500OptmonsProtGroupEntry 3 }
cienaOme6500OptmonsProtGroupProtIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { cienaOme6500OptmonsProtGroupEntry 4 }
cienaOme6500OptmonsProtGroupProtIfDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "AID in format OPTMON-shelf-slot-port, OPTMON-shelf-ALL"
::= { cienaOme6500OptmonsProtGroupEntry 5 }
cienaOme6500OptmonsProtGroupProtSst OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Identify the secondary state"
::= { cienaOme6500OptmonsProtGroupEntry 6 }
cienaOme6500OptmonsProtGroupProtScheme OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the protection scheme to be used."
::= { cienaOme6500OptmonsProtGroupEntry 7 }
cienaOme6500OptmonsProtGroupWaitToRestore OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Wait-to-restore period in minutes"
::= { cienaOme6500OptmonsProtGroupEntry 8 }
cienaOme6500OptmonsProtGroupDetectGuardTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Detection Guard DisplayString (supported on SDHJ only) "
::= { cienaOme6500OptmonsProtGroupEntry 9 }
cienaOme6500OptmonsProtGroupRevertive OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Revertive switching mode enabled?"
::= { cienaOme6500OptmonsProtGroupEntry 10 }
cienaOme6500OptmonsProtGroupRemStandard OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Standard used on the remote equipment"
::= { cienaOme6500OptmonsProtGroupEntry 11 }
cienaOme6500OptmonsProtGroupLossPwr OBJECT-TYPE
SYNTAX INTEGER { n(0), y(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Loss of Power Supply mode"
::= { cienaOme6500OptmonsProtGroupEntry 12 }
cienaOme6500OptmonsProtGroupTtops OBJECT-TYPE
SYNTAX INTEGER { n(0), y(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Transponder Triggered Switching Mode Enabled"
::= { cienaOme6500OptmonsProtGroupEntry 13 }
cienaOme6500OptmonsProtGroupPsDirn OBJECT-TYPE
SYNTAX INTEGER { uni(0), bi(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Protection Switch Direction.Default=UNI."
::= { cienaOme6500OptmonsProtGroupEntry 14 }
END -- End module