-- BDCOM-SYS.my: BDCom System MIB file
|
|
--
|
|
-- Jun 2000
|
|
--
|
|
-- *****************************************************************
|
|
|
|
BDCOM-SYS DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
IpAddress
|
|
FROM RFC1155-SMI
|
|
OBJECT-TYPE
|
|
FROM RFC-1212
|
|
DisplayString
|
|
FROM RFC1213-MIB
|
|
bdlocal
|
|
FROM BDCOM-SMI;
|
|
|
|
bdlsystem OBJECT IDENTIFIER ::= { bdlocal 1 }
|
|
|
|
-- Local Variable Section
|
|
|
|
-- This section describes the local variables within the BDCom
|
|
-- product line. Groups may or may not be present depending
|
|
-- on the software options present in the managed device.
|
|
|
|
|
|
-- Local System Group
|
|
|
|
-- This group is present in all products.
|
|
|
|
bdromId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable contains a printable octet
|
|
string which contains the System Bootstrap
|
|
description and version identification."
|
|
::= { bdlsystem 1 }
|
|
|
|
bdwhyReload OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable contains a printable octet
|
|
string which contains the reason why the
|
|
system was last restarted."
|
|
::= { bdlsystem 2 }
|
|
|
|
bdhostName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable represents the name of the
|
|
host in printable ascii characters."
|
|
::= { bdlsystem 3 }
|
|
|
|
bddomainName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is the domain portion of the
|
|
domain name of the host."
|
|
::= { bdlsystem 4 }
|
|
|
|
bdauthAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable contains the last SNMP
|
|
authorization failure IP address."
|
|
::= { bdlsystem 5 }
|
|
|
|
bdbootHost OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the IP address of the host that
|
|
supplied the currently running software."
|
|
::= { bdlsystem 6 }
|
|
|
|
bdping OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The ping mib object is obsolete as of IOS 10.2
|
|
It has been superseded by the BDCom Ping MIB"
|
|
::= { bdlsystem 7 }
|
|
|
|
bdfreeMem OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The freeMem mib object is obsolete as of IOS 11.1
|
|
It has been replaced with the BDCom memory pool mib"
|
|
::= { bdlsystem 8 }
|
|
|
|
bdbufferElFree OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of free buffer
|
|
elements."
|
|
::= { bdlsystem 9 }
|
|
|
|
bdbufferElMax OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the maximum number of buffer
|
|
elements."
|
|
::= { bdlsystem 10 }
|
|
|
|
bdbufferElHit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of buffer element hits."
|
|
::= { bdlsystem 11 }
|
|
|
|
bdbufferElMiss OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of buffer element
|
|
misses."
|
|
::= { bdlsystem 12 }
|
|
|
|
bdbufferElCreate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of buffer element
|
|
creates."
|
|
::= { bdlsystem 13 }
|
|
|
|
bdbufferSmSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the size of small buffers."
|
|
::= { bdlsystem 14 }
|
|
|
|
bdbufferSmTotal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the total number of small buffers."
|
|
::= { bdlsystem 15 }
|
|
|
|
bdbufferSmFree OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of free small buffers."
|
|
::= { bdlsystem 16 }
|
|
|
|
bdbufferSmMax OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the maximum number of small
|
|
buffers."
|
|
::= { bdlsystem 17 }
|
|
|
|
bdbufferSmHit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of small buffer hits."
|
|
::= { bdlsystem 18 }
|
|
|
|
bdbufferSmMiss OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of small buffer misses."
|
|
::= { bdlsystem 19 }
|
|
|
|
bdbufferSmTrim OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of small buffer trims."
|
|
::= { bdlsystem 20 }
|
|
|
|
bdbufferSmCreate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of small buffer
|
|
creates."
|
|
::= { bdlsystem 21 }
|
|
|
|
bdbufferMdSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the size of medium buffers."
|
|
::= { bdlsystem 22 }
|
|
|
|
bdbufferMdTotal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the total number of medium
|
|
buffers."
|
|
::= { bdlsystem 23 }
|
|
|
|
bdbufferMdFree OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of free medium buffers."
|
|
::= { bdlsystem 24 }
|
|
|
|
bdbufferMdMax OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the maximum number of medium
|
|
buffers."
|
|
::= { bdlsystem 25 }
|
|
|
|
bdbufferMdHit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of medium buffer hits."
|
|
::= { bdlsystem 26 }
|
|
|
|
bdbufferMdMiss OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of medium buffer
|
|
misses."
|
|
::= { bdlsystem 27 }
|
|
|
|
bdbufferMdTrim OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of medium buffer trims."
|
|
::= { bdlsystem 28 }
|
|
|
|
bdbufferMdCreate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of medium buffer
|
|
creates."
|
|
::= { bdlsystem 29 }
|
|
|
|
bdbufferBgSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the size of big buffers."
|
|
::= { bdlsystem 30 }
|
|
|
|
bdbufferBgTotal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the total number of big buffers."
|
|
::= { bdlsystem 31 }
|
|
|
|
bdbufferBgFree OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of free big buffers."
|
|
::= { bdlsystem 32 }
|
|
|
|
bdbufferBgMax OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the maximum number of big buffers."
|
|
::= { bdlsystem 33 }
|
|
|
|
bdbufferBgHit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of big buffer hits."
|
|
::= { bdlsystem 34 }
|
|
|
|
bdbufferBgMiss OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of big buffer misses."
|
|
::= { bdlsystem 35 }
|
|
|
|
bdbufferBgTrim OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of big buffer trims."
|
|
::= { bdlsystem 36 }
|
|
|
|
bdbufferBgCreate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of big buffer creates."
|
|
::= { bdlsystem 37 }
|
|
|
|
bdbufferLgSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the size of large buffers."
|
|
::= { bdlsystem 38 }
|
|
|
|
bdbufferLgTotal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the total number of large buffers."
|
|
::= { bdlsystem 39 }
|
|
|
|
bdbufferLgFree OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of free large buffers."
|
|
::= { bdlsystem 40 }
|
|
|
|
bdbufferLgMax OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the maximum number of large
|
|
buffers."
|
|
::= { bdlsystem 41 }
|
|
|
|
bdbufferLgHit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of large buffer hits."
|
|
::= { bdlsystem 42 }
|
|
|
|
bdbufferLgMiss OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of large buffer misses."
|
|
::= { bdlsystem 43 }
|
|
|
|
bdbufferLgTrim OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of large buffer trims."
|
|
::= { bdlsystem 44 }
|
|
|
|
bdbufferLgCreate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of large buffer
|
|
creates."
|
|
::= { bdlsystem 45 }
|
|
|
|
bdbufferFail OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of the number of buffer allocation
|
|
failures."
|
|
::= { bdlsystem 46 }
|
|
|
|
bdbufferNoMem OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of the number of buffer create
|
|
failures due to no free memory."
|
|
::= { bdlsystem 47 }
|
|
|
|
bdnetConfigAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Holds the address of the host that supplied
|
|
the network-confg file."
|
|
::= { bdlsystem 48 }
|
|
|
|
bdnetConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Holds the name of the network configuration
|
|
file."
|
|
::= { bdlsystem 49 }
|
|
|
|
bdnetConfigSet OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Cause the loading of a new network-confg
|
|
file using TFTP."
|
|
::= { bdlsystem 50 }
|
|
|
|
bdhostConfigAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Contains the address of the host that
|
|
provided the host-config file."
|
|
::= { bdlsystem 51 }
|
|
|
|
bdhostConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Contains the name of the last configured
|
|
host-confg file."
|
|
::= { bdlsystem 52 }
|
|
|
|
bdhostConfigSet OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS write-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Cause the loading of a new host-confg file
|
|
using TFTP."
|
|
::= { bdlsystem 53 }
|
|
|
|
bdwriteMem OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Write configuration into non-volatile memory
|
|
/ erase config memory if 0."
|
|
::= { bdlsystem 54 }
|
|
|
|
bdwriteNet OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Write configuration to host using TFTP."
|
|
::= { bdlsystem 55 }
|
|
|
|
bdbusyPer OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"CPU busy percentage in the last 5 second
|
|
period. Not the last 5 realtime seconds but
|
|
the last 5 second period in the scheduler."
|
|
::= { bdlsystem 56 }
|
|
|
|
bdavgBusy1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"1 minute exponentially-decayed moving
|
|
average of the CPU busy percentage."
|
|
::= { bdlsystem 57 }
|
|
|
|
bdavgBusy5 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"5 minute exponentially-decayed moving
|
|
average of the CPU busy percentage."
|
|
::= { bdlsystem 58 }
|
|
|
|
bdidleCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"BDCom internal variable. not to be used"
|
|
::= { bdlsystem 59 }
|
|
|
|
bdidleWired OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"BDCom internal variable. not to be used"
|
|
::= { bdlsystem 60 }
|
|
|
|
bdContactInfo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"BDCom's name and address"
|
|
::= { bdlsystem 61 }
|
|
|
|
bdbufferHgSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the size of huge buffers."
|
|
::= { bdlsystem 62 }
|
|
|
|
bdbufferHgTotal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the total number of huge buffers."
|
|
::= { bdlsystem 63 }
|
|
|
|
bdbufferHgFree OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of free huge buffers."
|
|
::= { bdlsystem 64 }
|
|
|
|
bdbufferHgMax OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the maximum number of huge
|
|
buffers."
|
|
::= { bdlsystem 65 }
|
|
|
|
bdbufferHgHit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of huge buffer hits."
|
|
::= { bdlsystem 66 }
|
|
|
|
bdbufferHgMiss OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of huge buffer misses."
|
|
::= { bdlsystem 67 }
|
|
|
|
bdbufferHgTrim OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of huge buffer trims."
|
|
::= { bdlsystem 68 }
|
|
|
|
bdbufferHgCreate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the number of huge buffer creates."
|
|
::= { bdlsystem 69 }
|
|
|
|
bdnetConfigProto OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Holds the protocol that supplied the
|
|
network-confg file."
|
|
::= { bdlsystem 70 }
|
|
|
|
bdhostConfigProto OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Holds the protocol that supplied the host-
|
|
confg file."
|
|
::= { bdlsystem 71 }
|
|
|
|
bdsysConfigAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Holds the address of the host that supplied
|
|
the system boot image."
|
|
::= { bdlsystem 72 }
|
|
|
|
bdsysConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Holds the name of the system boot image."
|
|
::= { bdlsystem 73 }
|
|
|
|
bdsysConfigProto OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Holds the protocol that supplied the system
|
|
boot image."
|
|
::= { bdlsystem 74 }
|
|
|
|
bdsysClearARP OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Perform a clearing of the entire ARP cache
|
|
and invalidation of route caches."
|
|
::= { bdlsystem 75 }
|
|
|
|
bdsysClearInt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clear interface given IfIndex as value."
|
|
::= { bdlsystem 76 }
|
|
|
|
bdenvPresent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Is there an environmental monitor card in
|
|
this box?, 0 - No, 1-AGS card present, wrong
|
|
firmware, 2-AGS CARD present, firmware ok,
|
|
3-7000 support"
|
|
::= { bdlsystem 77 }
|
|
|
|
bdenvTestPt1Descr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the test point 1. Typically
|
|
ambient air or the temperature of air
|
|
entering the router"
|
|
::= { bdlsystem 78 }
|
|
|
|
bdenvTestPt1Measure OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current value of test point 1. Typically a
|
|
temperature in centigrade."
|
|
::= { bdlsystem 79 }
|
|
|
|
bdenvTestPt2Descr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the test point 2. Typically
|
|
airflow or the temperature of air leaving the
|
|
router"
|
|
::= { bdlsystem 80 }
|
|
|
|
bdenvTestPt2Measure OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current value of test point 2. Typically a
|
|
temperature in centigrade."
|
|
::= { bdlsystem 81 }
|
|
|
|
bdenvTestPt3Descr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the test point 3. Typically
|
|
+5 volt"
|
|
::= { bdlsystem 82 }
|
|
|
|
bdenvTestPt3Measure OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current value of test point 3. Typically the
|
|
value in millivolts of the +5v supply"
|
|
::= { bdlsystem 83 }
|
|
|
|
bdenvTestPt4Descr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the test point 4. Typically
|
|
+12 volt"
|
|
::= { bdlsystem 84 }
|
|
|
|
bdenvTestPt4Measure OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current value of test point 4. Typically the
|
|
value in millivolts of the +12v supply"
|
|
::= { bdlsystem 85 }
|
|
|
|
bdenvTestPt5Descr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the test point 5. Typically
|
|
-12 volt"
|
|
::= { bdlsystem 86 }
|
|
|
|
bdenvTestPt5Measure OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current value of test point 5. Typically the
|
|
value in millivolts of the -12v supply"
|
|
::= { bdlsystem 87 }
|
|
|
|
bdenvTestPt6Descr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the test point 6. Typically
|
|
-5 volt"
|
|
::= { bdlsystem 88 }
|
|
|
|
bdenvTestPt6Measure OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current value of test point 6. Typically the
|
|
value in millivolts of the -5v supply"
|
|
::= { bdlsystem 89 }
|
|
|
|
bdenvTestPt1MarginVal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value at which the router will shutdown.
|
|
Typically the ambient air temperature that
|
|
will shut the router down. (e.g. 43)"
|
|
::= { bdlsystem 90 }
|
|
|
|
bdenvTestPt2MarginVal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value at which the router will shutdown.
|
|
Typically the airflow air temperature that
|
|
will shut the router down. (e.g. 58)"
|
|
::= { bdlsystem 91 }
|
|
|
|
bdenvTestPt3MarginPercent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+/- Percentage that will shut the router
|
|
down, (e.g. 10%) typically +5 volt"
|
|
::= { bdlsystem 92 }
|
|
|
|
bdenvTestPt4MarginPercent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+/- Percentage that will shut the router
|
|
down, (e.g. 15%) typically +12 volt"
|
|
::= { bdlsystem 93 }
|
|
|
|
bdenvTestPt5MarginPercent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+/- Percentage that will shut the router
|
|
down, (e.g. 15%) typically -12 volt"
|
|
::= { bdlsystem 94 }
|
|
|
|
bdenvTestPt6MarginPercent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+/- Percentage that will shut the router
|
|
down, (e.g. 10%) typically -5 volt"
|
|
::= { bdlsystem 95 }
|
|
|
|
bdenvTestPt1last OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of TestPt1 when last shutdown
|
|
occurred."
|
|
::= { bdlsystem 96 }
|
|
|
|
bdenvTestPt2last OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of TestPt2 when last shutdown
|
|
occurred."
|
|
::= { bdlsystem 97 }
|
|
|
|
bdenvTestPt3last OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of TestPt3 when last shutdown
|
|
occurred."
|
|
::= { bdlsystem 98 }
|
|
|
|
bdenvTestPt4last OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of TestPt4 when last shutdown
|
|
occurred."
|
|
::= { bdlsystem 99 }
|
|
|
|
bdenvTestPt5last OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of TestPt5 when last shutdown
|
|
occurred."
|
|
::= { bdlsystem 100 }
|
|
|
|
bdenvTestPt6last OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of TestPt6 when last shutdown
|
|
occurred."
|
|
::= { bdlsystem 101 }
|
|
|
|
bdenvTestPt1warn OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
warning(1),
|
|
noWarning(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Is this test point at a warning level?"
|
|
::= { bdlsystem 102 }
|
|
|
|
bdenvTestPt2warn OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
warning(1),
|
|
noWarning(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Is this test point at a warning level?"
|
|
::= { bdlsystem 103 }
|
|
|
|
bdenvTestPt3warn OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
warning(1),
|
|
noWarning(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Is this test point at a warning level?"
|
|
::= { bdlsystem 104 }
|
|
|
|
bdenvTestPt4warn OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
warning(1),
|
|
noWarning(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Is this test point at a warning level?"
|
|
::= { bdlsystem 105 }
|
|
|
|
bdenvTestPt5warn OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
warning(1),
|
|
noWarning(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Is this test point at a warning level?"
|
|
::= { bdlsystem 106 }
|
|
|
|
bdenvTestPt6warn OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
warning(1),
|
|
noWarning(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Is this test point at a warning level?"
|
|
::= { bdlsystem 107 }
|
|
|
|
bdenvFirmVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of Environmental Card firmware"
|
|
::= { bdlsystem 108 }
|
|
|
|
bdenvTechnicianID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Technician ID"
|
|
::= { bdlsystem 109 }
|
|
|
|
bdenvType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of environmental card"
|
|
::= { bdlsystem 110 }
|
|
|
|
bdenvBurnDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The calibration / burn in date"
|
|
::= { bdlsystem 111 }
|
|
|
|
bdenvSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Serial Number of environmental monitor card"
|
|
::= { bdlsystem 112 }
|
|
|
|
|
|
END
|