-- ***************************************************************** -- BDCOM-SYS.my: BDCom System MIB file -- -- Jun 2000 -- -- ***************************************************************** BDCOM-SYS DEFINITIONS ::= BEGIN IMPORTS IpAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB bdlocal FROM BDCOM-SMI; bdlsystem OBJECT IDENTIFIER ::= { bdlocal 1 } -- Local Variable Section -- This section describes the local variables within the BDCom -- product line. Groups may or may not be present depending -- on the software options present in the managed device. -- Local System Group -- This group is present in all products. bdromId OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable contains a printable octet string which contains the System Bootstrap description and version identification." ::= { bdlsystem 1 } bdwhyReload OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable contains a printable octet string which contains the reason why the system was last restarted." ::= { bdlsystem 2 } bdhostName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the name of the host in printable ascii characters." ::= { bdlsystem 3 } bddomainName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable is the domain portion of the domain name of the host." ::= { bdlsystem 4 } bdauthAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This variable contains the last SNMP authorization failure IP address." ::= { bdlsystem 5 } bdbootHost OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Contains the IP address of the host that supplied the currently running software." ::= { bdlsystem 6 } bdping OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS obsolete DESCRIPTION "The ping mib object is obsolete as of IOS 10.2 It has been superseded by the BDCom Ping MIB" ::= { bdlsystem 7 } bdfreeMem OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "The freeMem mib object is obsolete as of IOS 11.1 It has been replaced with the BDCom memory pool mib" ::= { bdlsystem 8 } bdbufferElFree OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of free buffer elements." ::= { bdlsystem 9 } bdbufferElMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the maximum number of buffer elements." ::= { bdlsystem 10 } bdbufferElHit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of buffer element hits." ::= { bdlsystem 11 } bdbufferElMiss OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of buffer element misses." ::= { bdlsystem 12 } bdbufferElCreate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of buffer element creates." ::= { bdlsystem 13 } bdbufferSmSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the size of small buffers." ::= { bdlsystem 14 } bdbufferSmTotal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the total number of small buffers." ::= { bdlsystem 15 } bdbufferSmFree OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of free small buffers." ::= { bdlsystem 16 } bdbufferSmMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the maximum number of small buffers." ::= { bdlsystem 17 } bdbufferSmHit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of small buffer hits." ::= { bdlsystem 18 } bdbufferSmMiss OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of small buffer misses." ::= { bdlsystem 19 } bdbufferSmTrim OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of small buffer trims." ::= { bdlsystem 20 } bdbufferSmCreate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of small buffer creates." ::= { bdlsystem 21 } bdbufferMdSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the size of medium buffers." ::= { bdlsystem 22 } bdbufferMdTotal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the total number of medium buffers." ::= { bdlsystem 23 } bdbufferMdFree OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of free medium buffers." ::= { bdlsystem 24 } bdbufferMdMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the maximum number of medium buffers." ::= { bdlsystem 25 } bdbufferMdHit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of medium buffer hits." ::= { bdlsystem 26 } bdbufferMdMiss OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of medium buffer misses." ::= { bdlsystem 27 } bdbufferMdTrim OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of medium buffer trims." ::= { bdlsystem 28 } bdbufferMdCreate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of medium buffer creates." ::= { bdlsystem 29 } bdbufferBgSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the size of big buffers." ::= { bdlsystem 30 } bdbufferBgTotal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the total number of big buffers." ::= { bdlsystem 31 } bdbufferBgFree OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of free big buffers." ::= { bdlsystem 32 } bdbufferBgMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the maximum number of big buffers." ::= { bdlsystem 33 } bdbufferBgHit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of big buffer hits." ::= { bdlsystem 34 } bdbufferBgMiss OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of big buffer misses." ::= { bdlsystem 35 } bdbufferBgTrim OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of big buffer trims." ::= { bdlsystem 36 } bdbufferBgCreate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of big buffer creates." ::= { bdlsystem 37 } bdbufferLgSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the size of large buffers." ::= { bdlsystem 38 } bdbufferLgTotal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the total number of large buffers." ::= { bdlsystem 39 } bdbufferLgFree OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of free large buffers." ::= { bdlsystem 40 } bdbufferLgMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the maximum number of large buffers." ::= { bdlsystem 41 } bdbufferLgHit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of large buffer hits." ::= { bdlsystem 42 } bdbufferLgMiss OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of large buffer misses." ::= { bdlsystem 43 } bdbufferLgTrim OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of large buffer trims." ::= { bdlsystem 44 } bdbufferLgCreate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of large buffer creates." ::= { bdlsystem 45 } bdbufferFail OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Count of the number of buffer allocation failures." ::= { bdlsystem 46 } bdbufferNoMem OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Count of the number of buffer create failures due to no free memory." ::= { bdlsystem 47 } bdnetConfigAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Holds the address of the host that supplied the network-confg file." ::= { bdlsystem 48 } bdnetConfigName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Holds the name of the network configuration file." ::= { bdlsystem 49 } bdnetConfigSet OBJECT-TYPE SYNTAX DisplayString ACCESS write-only STATUS mandatory DESCRIPTION "Cause the loading of a new network-confg file using TFTP." ::= { bdlsystem 50 } bdhostConfigAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS obsolete DESCRIPTION "Contains the address of the host that provided the host-config file." ::= { bdlsystem 51 } bdhostConfigName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS obsolete DESCRIPTION "Contains the name of the last configured host-confg file." ::= { bdlsystem 52 } bdhostConfigSet OBJECT-TYPE SYNTAX DisplayString ACCESS write-only STATUS obsolete DESCRIPTION "Cause the loading of a new host-confg file using TFTP." ::= { bdlsystem 53 } bdwriteMem OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Write configuration into non-volatile memory / erase config memory if 0." ::= { bdlsystem 54 } bdwriteNet OBJECT-TYPE SYNTAX DisplayString ACCESS write-only STATUS mandatory DESCRIPTION "Write configuration to host using TFTP." ::= { bdlsystem 55 } bdbusyPer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "CPU busy percentage in the last 5 second period. Not the last 5 realtime seconds but the last 5 second period in the scheduler." ::= { bdlsystem 56 } bdavgBusy1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "1 minute exponentially-decayed moving average of the CPU busy percentage." ::= { bdlsystem 57 } bdavgBusy5 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "5 minute exponentially-decayed moving average of the CPU busy percentage." ::= { bdlsystem 58 } bdidleCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "BDCom internal variable. not to be used" ::= { bdlsystem 59 } bdidleWired OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "BDCom internal variable. not to be used" ::= { bdlsystem 60 } bdContactInfo OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "BDCom's name and address" ::= { bdlsystem 61 } bdbufferHgSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the size of huge buffers." ::= { bdlsystem 62 } bdbufferHgTotal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the total number of huge buffers." ::= { bdlsystem 63 } bdbufferHgFree OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of free huge buffers." ::= { bdlsystem 64 } bdbufferHgMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the maximum number of huge buffers." ::= { bdlsystem 65 } bdbufferHgHit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of huge buffer hits." ::= { bdlsystem 66 } bdbufferHgMiss OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of huge buffer misses." ::= { bdlsystem 67 } bdbufferHgTrim OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of huge buffer trims." ::= { bdlsystem 68 } bdbufferHgCreate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the number of huge buffer creates." ::= { bdlsystem 69 } bdnetConfigProto OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Holds the protocol that supplied the network-confg file." ::= { bdlsystem 70 } bdhostConfigProto OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Holds the protocol that supplied the host- confg file." ::= { bdlsystem 71 } bdsysConfigAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Holds the address of the host that supplied the system boot image." ::= { bdlsystem 72 } bdsysConfigName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Holds the name of the system boot image." ::= { bdlsystem 73 } bdsysConfigProto OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Holds the protocol that supplied the system boot image." ::= { bdlsystem 74 } bdsysClearARP OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Perform a clearing of the entire ARP cache and invalidation of route caches." ::= { bdlsystem 75 } bdsysClearInt OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Clear interface given IfIndex as value." ::= { bdlsystem 76 } bdenvPresent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Is there an environmental monitor card in this box?, 0 - No, 1-AGS card present, wrong firmware, 2-AGS CARD present, firmware ok, 3-7000 support" ::= { bdlsystem 77 } bdenvTestPt1Descr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Description of the test point 1. Typically ambient air or the temperature of air entering the router" ::= { bdlsystem 78 } bdenvTestPt1Measure OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current value of test point 1. Typically a temperature in centigrade." ::= { bdlsystem 79 } bdenvTestPt2Descr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Description of the test point 2. Typically airflow or the temperature of air leaving the router" ::= { bdlsystem 80 } bdenvTestPt2Measure OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current value of test point 2. Typically a temperature in centigrade." ::= { bdlsystem 81 } bdenvTestPt3Descr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Description of the test point 3. Typically +5 volt" ::= { bdlsystem 82 } bdenvTestPt3Measure OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current value of test point 3. Typically the value in millivolts of the +5v supply" ::= { bdlsystem 83 } bdenvTestPt4Descr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Description of the test point 4. Typically +12 volt" ::= { bdlsystem 84 } bdenvTestPt4Measure OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current value of test point 4. Typically the value in millivolts of the +12v supply" ::= { bdlsystem 85 } bdenvTestPt5Descr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Description of the test point 5. Typically -12 volt" ::= { bdlsystem 86 } bdenvTestPt5Measure OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current value of test point 5. Typically the value in millivolts of the -12v supply" ::= { bdlsystem 87 } bdenvTestPt6Descr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Description of the test point 6. Typically -5 volt" ::= { bdlsystem 88 } bdenvTestPt6Measure OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current value of test point 6. Typically the value in millivolts of the -5v supply" ::= { bdlsystem 89 } bdenvTestPt1MarginVal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value at which the router will shutdown. Typically the ambient air temperature that will shut the router down. (e.g. 43)" ::= { bdlsystem 90 } bdenvTestPt2MarginVal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value at which the router will shutdown. Typically the airflow air temperature that will shut the router down. (e.g. 58)" ::= { bdlsystem 91 } bdenvTestPt3MarginPercent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "+/- Percentage that will shut the router down, (e.g. 10%) typically +5 volt" ::= { bdlsystem 92 } bdenvTestPt4MarginPercent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "+/- Percentage that will shut the router down, (e.g. 15%) typically +12 volt" ::= { bdlsystem 93 } bdenvTestPt5MarginPercent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "+/- Percentage that will shut the router down, (e.g. 15%) typically -12 volt" ::= { bdlsystem 94 } bdenvTestPt6MarginPercent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "+/- Percentage that will shut the router down, (e.g. 10%) typically -5 volt" ::= { bdlsystem 95 } bdenvTestPt1last OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of TestPt1 when last shutdown occurred." ::= { bdlsystem 96 } bdenvTestPt2last OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of TestPt2 when last shutdown occurred." ::= { bdlsystem 97 } bdenvTestPt3last OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of TestPt3 when last shutdown occurred." ::= { bdlsystem 98 } bdenvTestPt4last OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of TestPt4 when last shutdown occurred." ::= { bdlsystem 99 } bdenvTestPt5last OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of TestPt5 when last shutdown occurred." ::= { bdlsystem 100 } bdenvTestPt6last OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value of TestPt6 when last shutdown occurred." ::= { bdlsystem 101 } bdenvTestPt1warn OBJECT-TYPE SYNTAX INTEGER { warning(1), noWarning(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Is this test point at a warning level?" ::= { bdlsystem 102 } bdenvTestPt2warn OBJECT-TYPE SYNTAX INTEGER { warning(1), noWarning(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Is this test point at a warning level?" ::= { bdlsystem 103 } bdenvTestPt3warn OBJECT-TYPE SYNTAX INTEGER { warning(1), noWarning(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Is this test point at a warning level?" ::= { bdlsystem 104 } bdenvTestPt4warn OBJECT-TYPE SYNTAX INTEGER { warning(1), noWarning(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Is this test point at a warning level?" ::= { bdlsystem 105 } bdenvTestPt5warn OBJECT-TYPE SYNTAX INTEGER { warning(1), noWarning(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Is this test point at a warning level?" ::= { bdlsystem 106 } bdenvTestPt6warn OBJECT-TYPE SYNTAX INTEGER { warning(1), noWarning(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Is this test point at a warning level?" ::= { bdlsystem 107 } bdenvFirmVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Description of Environmental Card firmware" ::= { bdlsystem 108 } bdenvTechnicianID OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Technician ID" ::= { bdlsystem 109 } bdenvType OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The type of environmental card" ::= { bdlsystem 110 } bdenvBurnDate OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The calibration / burn in date" ::= { bdlsystem 111 } bdenvSerialNumber OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Serial Number of environmental monitor card" ::= { bdlsystem 112 } END