Observium_CE/mibs/asentria/SITEBOSS-220-STD-MIB

1893 lines
58 KiB
Plaintext

-- SiteBoss 220 MIB
-- v 1.01 06/13/13
-- Copyright (c) 2013 by Asentria Corporation. All rights reserved.
SITEBOSS-220-STD-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayString
FROM SNMPv2-TC
IpAddress, TimeTicks, Integer32,
MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE
FROM SNMPv2-SMI
asentria
FROM ASENTRIA-ROOT-MIB;
--***************************************************************************************
--MODULE IDENTITY
--***************************************************************************************
s220 MODULE-IDENTITY
LAST-UPDATED "201306130101Z"
ORGANIZATION "Asentria Corporation"
CONTACT-INFO
"Phone: 206-344-8800
Fax: 206-344-2116
Email: support@asentria.com"
DESCRIPTION
"MIB module for managing Asentria SiteBoss 220"
REVISION "201306130101Z"
DESCRIPTION
"-v1.01
-Added missing esPointConfigAITable branch (UTSK-7).
-Applicable since unit version 1.01.002."
REVISION "201306070100Z"
DESCRIPTION
"-v1.00
-Initial release"
::= { asentria 43 }
--1.3.6.1.4.1.3052.43
--***************************************************************************************
--MIB View
--***************************************************************************************
-- status .1
-- eventSensorStatus .1.1
-- esPointTable .1.1.1
-- esPointEntry .1.1.1.1
-- esIndexES .1.1.1.1.1
-- esIndexPC .1.1.1.1.2
-- esIndexPoint .1.1.1.1.3
-- esPointName .1.1.1.1.4
-- esPointInEventState .1.1.1.1.5
-- esPointValueInt .1.1.1.1.6
-- esPointValueStr .1.1.1.1.7
-- config .2
-- eventSensorBasics .2.1
-- eventSensorPointConfig .2.2
-- esPointConfigTempTable .2.2.1
-- esPointConfigTempEntry .2.2.1.1
-- espcTempIndexES .2.2.1.1.1
-- espcTempIndexPoint .2.2.1.1.2
-- espcTempEnable .2.2.1.1.3
-- espcTempName .2.2.1.1.4
-- espcTempScale .2.2.1.1.5
-- espcTempDeadband .2.2.1.1.6
-- espcTempVHighTemp .2.2.1.1.7
-- espcTempVHighClass .2.2.1.1.9
-- espcTempHighTemp .2.2.1.1.10
-- espcTempHighClass .2.2.1.1.13
-- espcTempNormalClass .2.2.1.1.16
-- espcTempLowTemp .2.2.1.1.17
-- espcTempLowClass .2.2.1.1.20
-- espcTempVLowTemp .2.2.1.1.21
-- espcTempVLowClass .2.2.1.1.24
-- espcTempActions .2.2.1.1.25
-- esPointConfigCCTable .2.2.2
-- esPointConfigCCEntry .2.2.2.1
-- espcCCIndexES .2.2.2.1.1
-- espcCCIndexPoint .2.2.2.1.2
-- espcCCEnable .2.2.2.1.3
-- espcCCName .2.2.2.1.4
-- espcCCEventState .2.2.2.1.5
-- espcCCThreshold .2.2.2.1.6
-- espcCCActions .2.2.2.1.7
-- espcCCEventClass .2.2.2.1.9
-- espcCCNormalClass .2.2.2.1.12
-- espcCCAlarmAlias .2.2.2.1.13
-- espcCCNormalAlias .2.2.2.1.14
-- esPointConfigHumidTable .2.2.3
-- esPointConfigHumidEntry .2.2.3.1
-- espcHumidIndexES .2.2.3.1.1
-- espcHumidIndexPoint .2.2.3.1.2
-- espcHumidEnable .2.2.3.1.3
-- espcHumidName .2.2.3.1.4
-- espcHumidDeadband .2.2.3.1.5
-- espcHumidVHighHumid .2.2.3.1.6
-- espcHumidVHighClass .2.2.3.1.8
-- espcHumidHighHumid .2.2.3.1.9
-- espcHumidHighClass .2.2.3.1.12
-- espcHumidLowHumid .2.2.3.1.16
-- espcHumidLowClass .2.2.3.1.19
-- espcHumidVLowHumid .2.2.3.1.20
-- espcHumidVLowClass .2.2.3.1.23
-- espcHumidActions .2.2.3.1.24
-- esPointConfigAITable .2.2.5
-- esPointConfigAIEntry .2.2.5.1
-- espcAIIndexES .2.2.5.1.1
-- espcAIIndexPoint .2.2.5.1.2
-- espcAIEnable .2.2.5.1.3
-- espcAIName .2.2.5.1.4
-- espcAIDeadband .2.2.5.1.5
-- espcAIVhighValue .2.2.5.1.6
-- espcAIVhighClass .2.2.5.1.8
-- espcAIHighValue .2.2.5.1.9
-- espcAIHighClass .2.2.5.1.12
-- espcAILowValue .2.2.5.1.16
-- espcAILowClass .2.2.5.1.19
-- espcAIVlowValue .2.2.5.1.20
-- espcAIVlowClass .2.2.5.1.23
-- espcAIActions .2.2.5.1.24
-- espcAIConvUnitName .2.2.5.1.25
-- espcAIConvLowValue .2.2.5.1.26
-- espcAIConvLowUnit .2.2.5.1.27
-- espcAIConvHighValue .2.2.5.1.28
-- espcAIConvHighUnit .2.2.5.1.29
-- esPointConfigRelayTable .2.2.6
-- esPointConfigRelayEntry .2.2.6.1
-- espcRelayIndexES .2.2.6.1.1
-- espcRelayIndexPoint .2.2.6.1.2
-- espcRelayEnable .2.2.6.1.3
-- espcRelayName .2.2.6.1.4
-- network .2.4
-- ethernet .2.4.1
-- ipAddress .2.4.1.1
-- subnetMask .2.4.1.2
-- router .2.4.1.3
-- snmp .2.4.8
-- snmpReadCommunity .2.4.8.2
-- snmpWriteCommunity .2.4.8.3
-- snmpTrapCommunity .2.4.8.4
-- snmpTable .2.4.8.6
-- snmpEntry .2.4.8.6.1
-- snmpIndex .2.4.8.6.1.1
-- snmpAddress .2.4.8.6.1.2
-- snmpTestMail .2.4.8.7
-- email .2.4.17
-- emailServer .2.4.17.1
-- emailDomain .2.4.17.2
-- emailAuthEnable .2.4.17.3
-- emailAuthUsername .2.4.17.4
-- emailAuthPassword .2.4.17.5
-- emailTable .2.4.17.6
-- emailEntry .2.4.17.6.1
-- emailIndex .2.4.17.6.1.1
-- emailAddress .2.4.17.6.1.2
-- emailTestMail .2.4.17.7
-- dateTime .2.8
-- date .2.8.1
-- time .2.8.2
-- autodst .2.8.3
-- action .2.14
-- actionSystemAlertAction .2.14.1
-- actionPowerupAlertEnable .2.14.2
-- actionRTNAlertsEnable .2.14.3
-- actionAlarmRepeatFrequency .2.14.4
-- sys .2.16
-- sysSerial .2.16.1
-- sysVersion .2.16.2
-- sysBuild .2.16.3
-- sysSitename .2.16.4
-- sysProduct .2.16.5
-- thisTrapText .2.16.6
--***************************************************************************************
--TOP-LEVEL OBJECT IDENTIFIERS
--***************************************************************************************
notification OBJECT IDENTIFIER ::= { s220 0 }
--1.3.6.1.4.1.3052.43.0
status OBJECT IDENTIFIER ::= { s220 1 }
--1.3.6.1.4.1.3052.43.1
eventSensorStatus OBJECT IDENTIFIER ::= { status 1 }
--1.3.6.1.4.1.3052.43.1.1
config OBJECT IDENTIFIER ::= { s220 2 }
--1.3.6.1.4.1.3052.43.2
eventSensorPointConfig OBJECT IDENTIFIER ::= { config 2 }
--1.3.6.1.4.1.3052.43.2.2
network OBJECT IDENTIFIER ::= { config 4 }
--1.3.6.1.4.1.3052.43.2.4
ethernet OBJECT IDENTIFIER ::= { network 1 }
--1.3.6.1.4.1.3052.43.2.4.1
snmp OBJECT IDENTIFIER ::= { network 8 }
--1.3.6.1.4.1.3052.43.2.4.8
email OBJECT IDENTIFIER ::= { network 17 }
--1.3.6.1.4.1.3052.43.2.4.17
dateTime OBJECT IDENTIFIER ::= { config 8 }
--1.3.6.1.4.1.3052.43.2.8
action OBJECT IDENTIFIER ::= { config 14 }
--1.3.6.1.4.1.3052.43.2.14
sys OBJECT IDENTIFIER ::= { config 16 }
--1.3.6.1.4.1.3052.43.2.16
--***************************************************************************************
--OBJECT DEFINITIONS
--***************************************************************************************
--***************************************************************************************
--EventSensor Status Section 1.1
--***************************************************************************************
esPointTable OBJECT-TYPE
SYNTAX SEQUENCE OF ESPoint
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
This table organizes 4 basic attributes of points. A point
is a particular sensor on an EventSensor (e.g., temperature,
humidity, contact closure 2, relay 5, etc.). The 4 point
attributes are its name, whether it's in its event state,
the point's value as a number and its value as a string.
Points are referenced by a point index. The point index
is a string of 3 numbers separated by periods.
It contains all the information necessary for getting a piece
of data off an event sensor; namely, which EventSensor,
point class, and which-sensor-of-that-class (a.k.a. point).
"
::= { eventSensorStatus 1 }
--1.3.6.1.4.1.3052.43.1.1.1
esPointEntry OBJECT-TYPE
SYNTAX ESPoint
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for EventSensor point table"
INDEX { esIndexES, esIndexPC, esIndexPoint }
::= { esPointTable 1 }
--1.3.6.1.4.1.3052.43.1.1.1.1
esIndexES OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that refers to an
EventSensor.
The point index is a string of 3 numbers separated
by periods. It contains all the information
necessary for getting a piece of data off an event
sensor; namely, which EventSensor, point class,
and which-sensor-of-that-class (a.k.a. point).
This object's allowable values are 1 through 16,
and 200. 200 always refers to the EventSensor
inside the unit. 1 through 16 refer to additional
attached EventSensors.
The number corresponding to an EventSensor is
determined by the user at the initial configuration
time. If there is an internal sensor in the unit,
it will always be the first item in the Sensor
Events setup menu.
For example, if a new EventSensor is configured as
the 2nd entry AFTER the internal EventSensor (if
one exists) in the Sensor Events Setup Menu, then
that EventSensor will be known from then on as
EventSensor 2. All point indeces with esIndexES=2
will now refer to that particular EventSensor.
"
::= { esPointEntry 1 }
--1.3.6.1.4.1.3052.43.1.1.1.1.1
esIndexPC OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that refers to point class.
The point index is a string of 3 numbers separated by periods.
It contains all the information necessary for getting a piece
of data off an event sensor; namely, which EventSensor,
point class, and which-sensor-of-that-class (a.k.a. point).
The values for this object are:
1=temperature sensor
2=contact closure
3=humidity sensor
4=noise sensor
5=analog input
6=relay
"
::= { esPointEntry 2 }
--1.3.6.1.4.1.3052.43.1.1.1.1.2
esIndexPoint OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that delineates which
sensor on the EventSensor.
So this combined with esIndexPC (Point Class or type)
and esIndexES (which EventSensor) uniquely defines each
point (sensor or relay) attached to a unit. For
example, if esIndexES is 3, esIndexPC is 1 and
esIndexPoint is 4 then this is the Fourth Temperature
Sensor on EventSensor number 3."
::= { esPointEntry 3 }
--1.3.6.1.4.1.3052.43.1.1.1.1.3
esPointName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the point on an EventSensor. For example,
'AC temp' (in the case of the temperature sensor on an
EventSensor).
There can be multiple points of the same point class on an
EventSensor (e.g., 8 contact closures) and multiple sensor
classes on an EventSensor (e.g., temperature, contact closure,
humidity).
If the point referenced by a given point index is solitary
(e.g., temperature sensor, because there can be only one on
an EventSensor), then this object reads as '<EventSensor
name>'. Setting this object for solitary point indices sets
the EventSensor name only.
On the other hand, if a given point is among other points of
the same point class on an EventSensor, then this object reads
as '<Sensor name>'. Setting this object for these NON-
solitary point indices sets the sensor name only - not the
EventSensor name."
::= { esPointEntry 4 }
--1.3.6.1.4.1.3052.43.1.1.1.1.4
esPointInEventState OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A number referring to the event state of a point
on an EventSensor. This number can have different
meanings depending on the point class.
If the point class is temperature, humidity, or
analog input, then the values of this object are:
1=very low
2=low
3=normal
4=high
5=very high
For contact closures the values of this object are:
1=point in event state
2=point in normal state
For relays the values of this object are:
1=relay energized (active)
2=relay de-energized (inactive)
For any point class and any point, if the event
state is undefined, then the value of this object
is 0.
For any point class except relay, this object is
read-only. For relays, setting this object to 1
puts the relay into its active (energized) state.
Setting it to 2 puts the relay into its inactive
(de-energized) state. Setting it to any
value greater than 2 puts the relay into its
active state for that many seconds (up to 3600),
after which time it puts the relay into its
inactive state.
"
::= { esPointEntry 5 }
--1.3.6.1.4.1.3052.43.1.1.1.1.5
esPointValueInt OBJECT-TYPE
SYNTAX Integer32 (-32768..32767)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A read-only number referring to the value of a
point on an EventSensor.
If the point class is temperature, then this object
is the temperature in its configured scale (default
is Fahrenheit).
If the point class is contact closure or relay, then
this object is either 0 (open) or 1 (closed).
If the point class is humidity, then this object
is the percent relative humidity.
If the point class is analog input, then this
object is the signed input value in tenths of the
configured units.
If the point class is relay, then this object is
either 1 (active a.k.a. energized) or 0
(inactive a.k.a. de-energized). This object cannot
be used to control the relay (use esPointInEventState
for that).
"
::= { esPointEntry 6 }
--1.3.6.1.4.1.3052.43.1.1.1.1.6
esPointValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A string referring to the value of a point on an
EventSensor.
For contact closures this object is either 'Open'
or 'Closed'.
For relays this object is either 'Active'
(energized) or 'Inactive' (de-energized).
For temperature and humidity point classes, this
object is the string representation of the
esPointValueInt object. For temperature, 'C' or
'F' is including in the string to indicate scale.
For analog inputs, this object is the string
representation of the plus/minus input in the
configured units appended with the unit name.
"
::= { esPointEntry 7 }
--1.3.6.1.4.1.3052.43.1.1.1.1.7
--***************************************************************************************
--EventSensor Point Config Section 2.2
--***************************************************************************************
esPointConfigTempTable OBJECT-TYPE
SYNTAX SEQUENCE OF ESPointConfigTemp
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes 3 basic attributes of temperature
sensor points. A point is a particular sensor on an
EventSensor. The 3 point attributes organizes in this table
are:
1. the configuration item (e.g., enable, name, etc.)
2. the eventsensor on which this point resides
3. the point number (always 1 for temp sensors)
Points are referenced by a point config index. The point
config index is a string of 2 numbers separated by periods.
It contains all the information necessary for getting a
piece of data off an event sensor within the context of this
emperature point config table ; namely, which EventSensor,
and which sensor (a.k.a. point) (always 1 for temperature
sensors).
"
::= { eventSensorPointConfig 1 }
--1.3.6.1.4.1.3052.43.2.2.1
esPointConfigTempEntry OBJECT-TYPE
SYNTAX ESPointConfigTemp
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for EventSensor point config temperature table"
INDEX { espcTempIndexES, espcTempIndexPoint }
::= { esPointConfigTempTable 1 }
--1.3.6.1.4.1.3052.43.2.2.1.1
espcTempIndexES OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that refers to an
EventSensor.
The point config index is a string of 2 numbers separated
by a period. It contains all the information
necessary for getting a piece of data off an event
sensor within the the context of the eventsensor point
config temperature table; namely, which EventSensor,
and which sensor (a.k.a. point).
This object's allowable values are 1 through 16,
and 200. 200 always refers to the EventSensor
inside the unit. 1 through 16 refer to additional
attached EventSensors.
The number corresponding to an EventSensor is
determined by the user at the initial configuration
time. If there is an internal sensor in the unit,
it will always be the first item in the Sensor
Events setup menu.
For example, if a new EventSensor is configured as
the 2nd entry AFTER the internal EventSensor (if
one exists) in the Sensor Events Setup Menu, then
that EventSensor will be known from then on as
EventSensor 2. All point indeces with esIndexES=2
will now refer to that particular EventSensor.
"
::= { esPointConfigTempEntry 1 }
--1.3.6.1.4.1.3052.43.2.2.1.1.1
espcTempIndexPoint OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that delineates which
sensor on the EventSensor.
So this combined with espcTempIndexES (which EventSensor)
uniquely defines each point attached to a unit within the
context of temperature point configuration."
::= { esPointConfigTempEntry 2 }
--1.3.6.1.4.1.3052.43.2.2.1.1.2
espcTempEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable this temperature sensor"
::= { esPointConfigTempEntry 3 }
--1.3.6.1.4.1.3052.43.2.2.1.1.3
espcTempName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of this temperature sensor"
::= { esPointConfigTempEntry 4 }
--1.3.6.1.4.1.3052.43.2.2.1.1.4
espcTempScale OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Scale (C/F) for this temperature sensor"
::= { esPointConfigTempEntry 5 }
--1.3.6.1.4.1.3052.43.2.2.1.1.5
espcTempDeadband OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Deadband for this temperature sensor"
::= { esPointConfigTempEntry 6 }
--1.3.6.1.4.1.3052.43.2.2.1.1.6
espcTempVHighTemp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high temperature event threshold for this temperature
sensor"
::= { esPointConfigTempEntry 7 }
--1.3.6.1.4.1.3052.43.2.2.1.1.7
espcTempVHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high temperature event class for this temperature
sensor"
::= { esPointConfigTempEntry 9 }
--1.3.6.1.4.1.3052.43.2.2.1.1.9
espcTempHighTemp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High temperature event threshold for this temperature
sensor"
::= { esPointConfigTempEntry 10 }
--1.3.6.1.4.1.3052.43.2.2.1.1.10
espcTempHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High temperature event class for this temperature sensor"
::= { esPointConfigTempEntry 13 }
--1.3.6.1.4.1.3052.43.2.2.1.1.13
espcTempLowTemp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low temperature event threshold for this temperature sensor"
::= { esPointConfigTempEntry 17 }
--1.3.6.1.4.1.3052.43.2.2.1.1.17
espcTempLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low temperature event class for this temperature sensor"
::= { esPointConfigTempEntry 20 }
--1.3.6.1.4.1.3052.43.2.2.1.1.20
espcTempVLowTemp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very Low temperature event threshold for this temperature
sensor"
::= { esPointConfigTempEntry 21 }
--1.3.6.1.4.1.3052.43.2.2.1.1.21
espcTempVLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very Low temperature event class for this temperature sensor"
::= { esPointConfigTempEntry 24 }
--1.3.6.1.4.1.3052.43.2.2.1.1.24
espcTempActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Temperature event Action"
::= { esPointConfigTempEntry 25 }
--1.3.6.1.4.1.3052.43.2.2.1.1.25
esPointConfigCCTable OBJECT-TYPE
SYNTAX SEQUENCE OF ESPointConfigCC
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes 3 basic attributes of contact closure
points. A point is a particular sensor on an EventSensor.
The 3 point attributes organizes in this table are:
1. the configuration item (e.g., enable, name, etc.)
2. the eventsensor on which this point resides
3. the point number
Points are referenced by a point config index. The point
config index is a string of 2 numbers separated by a period.
It contains all the information necessary for getting a piece
of data off an event sensor within the context of this
contact closure point config table ; namely, which
EventSensor and which sensor.
"
::= { eventSensorPointConfig 2 }
--1.3.6.1.4.1.3052.43.2.2.2
esPointConfigCCEntry OBJECT-TYPE
SYNTAX ESPointConfigCC
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for EventSensor point config contact closure table"
INDEX { espcCCIndexES, espcCCIndexPoint }
::= { esPointConfigCCTable 1 }
--1.3.6.1.4.1.3052.43.2.2.2.1
espcCCIndexES OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that refers to an
EventSensor.
The point config index is a string of 2 numbers separated
by a period. It contains all the information
necessary for getting a piece of data off an event
sensor within the the context of the eventsensor point
config contact closure table; namely, which EventSensor
and which sensor (a.k.a. point).
This object's allowable values are 1 through 16,
and 200. 200 always refers to the EventSensor
inside the unit. 1 through 16 refer to additional
attached EventSensors.
"
::= { esPointConfigCCEntry 1 }
--1.3.6.1.4.1.3052.43.2.2.2.1.1
espcCCIndexPoint OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that delineates which
sensor on the EventSensor.
So this combined with espcCCIndexES (which EventSensor)
uniquely defines each point attached to a unit within the
context of contact closure point configuration."
::= { esPointConfigCCEntry 2 }
--1.3.6.1.4.1.3052.43.2.2.2.1.2
espcCCEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable for this contact closure"
::= { esPointConfigCCEntry 3 }
--1.3.6.1.4.1.3052.43.2.2.2.1.3
espcCCName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name for this contact closure"
::= { esPointConfigCCEntry 4 }
--1.3.6.1.4.1.3052.43.2.2.2.1.4
espcCCEventState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Event state for this contact closure"
::= { esPointConfigCCEntry 5 }
--1.3.6.1.4.1.3052.43.2.2.2.1.5
espcCCThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Threshold (seconds) for this contact closure"
::= { esPointConfigCCEntry 6 }
--1.3.6.1.4.1.3052.43.2.2.2.1.6
espcCCActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Event class for this contact closure"
::= { esPointConfigCCEntry 7 }
--1.3.6.1.4.1.3052.43.2.2.2.1.7
espcCCEventClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Event class for this contact closure"
::= { esPointConfigCCEntry 9 }
--1.3.6.1.4.1.3052.43.2.2.2.1.9
espcCCNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return-to-normal class for this contact closure"
::= { esPointConfigCCEntry 12 }
--1.3.6.1.4.1.3052.43.2.2.2.1.12
espcCCAlarmAlias OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Event alias for this contact closure"
::= { esPointConfigCCEntry 13 }
--1.3.6.1.4.1.3052.43.2.2.2.1.13
espcCCNormalAlias OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return-to-normal alias for this contact closure"
::= { esPointConfigCCEntry 14 }
--1.3.6.1.4.1.3052.43.2.2.2.1.14
esPointConfigHumidTable OBJECT-TYPE
SYNTAX SEQUENCE OF ESPointConfigHumid
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes 3 basic attributes of humidity points.
A point is a particular sensor on an EventSensor. The 3
point attributes organizes in this table are:
1. the configuration item (e.g., enable, name, etc.)
2. the eventsensor on which this point resides
3. the point number (always 1 for humidity sensors)
Points are referenced by a point config index. The point
config index is a string of 2 numbers separated by a period.
It contains all the information necessary for getting a piece
of data off an event sensor within the context of this
humidity point config table ; namely, which EventSensor and
which sensor.
"
::= { eventSensorPointConfig 3 }
--1.3.6.1.4.1.3052.43.2.2.3
esPointConfigHumidEntry OBJECT-TYPE
SYNTAX ESPointConfigHumid
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for EventSensor point config humidity table"
INDEX { espcHumidIndexES, espcHumidIndexPoint }
::= { esPointConfigHumidTable 1 }
--1.3.6.1.4.1.3052.43.2.2.3.1
espcHumidIndexES OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that refers to an
EventSensor.
The point config index is a string of 2 numbers separated
by a period. It contains all the information
necessary for getting a piece of data off an event
sensor within the the context of the eventsensor point
config contact closure table; namely, which EventSensor
and which sensor (a.k.a. point).
This object's allowable values are 1 through 16,
and 200. 200 always refers to the EventSensor
inside the unit. 1 through 16 refer to additional
attached EventSensors.
"
::= { esPointConfigHumidEntry 1 }
--1.3.6.1.4.1.3052.43.2.2.3.1.1
espcHumidIndexPoint OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that delineates which
sensor on the EventSensor.
So this combined with espcHumidIndexES (which EventSensor)
uniquely defines each point attached to a unit within the
context of contact closure point configuration."
::= { esPointConfigHumidEntry 2 }
--1.3.6.1.4.1.3052.43.2.2.3.1.2
espcHumidEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable for this humidity sensor"
::= { esPointConfigHumidEntry 3 }
--1.3.6.1.4.1.3052.43.2.2.3.1.3
espcHumidName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name for this humidity sensor"
::= { esPointConfigHumidEntry 4 }
--1.3.6.1.4.1.3052.43.2.2.3.1.4
espcHumidDeadband OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Deadband for this humidity sensor"
::= { esPointConfigHumidEntry 5 }
--1.3.6.1.4.1.3052.43.2.2.3.1.5
espcHumidVHighHumid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event threshold for this humidity sensor"
::= { esPointConfigHumidEntry 6 }
--1.3.6.1.4.1.3052.43.2.2.3.1.6
espcHumidVHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event class for this humidity sensor"
::= { esPointConfigHumidEntry 8 }
--1.3.6.1.4.1.3052.43.2.2.3.1.8
espcHumidHighHumid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event threshold for this humidity sensor"
::= { esPointConfigHumidEntry 9 }
--1.3.6.1.4.1.3052.43.2.2.3.1.9
espcHumidHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event class for this humidity sensor"
::= { esPointConfigHumidEntry 12 }
--1.3.6.1.4.1.3052.43.2.2.3.1.12
espcHumidLowHumid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event threshold for this humidity sensor"
::= { esPointConfigHumidEntry 16 }
--1.3.6.1.4.1.3052.43.2.2.3.1.16
espcHumidLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event class for this humidity sensor"
::= { esPointConfigHumidEntry 19 }
--1.3.6.1.4.1.3052.43.2.2.3.1.19
espcHumidVLowHumid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event threshold for this humidity sensor"
::= { esPointConfigHumidEntry 20 }
--1.3.6.1.4.1.3052.43.2.2.3.1.20
espcHumidVLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event class for this humidity sensor"
::= { esPointConfigHumidEntry 23 }
--1.3.6.1.4.1.3052.43.2.2.3.1.23
espcHumidActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Humidity event actions for this humidity sensor"
::= { esPointConfigHumidEntry 24 }
--1.3.6.1.4.1.3052.43.2.2.3.1.24
esPointConfigAITable OBJECT-TYPE
SYNTAX SEQUENCE OF ESPointConfigAnalogInput
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes 3 basic attributes of analog input
points. A point is a particular sensor on an EventSensor.
The 3 point attributes organizes in this table are:
1. the configuration item (e.g., enable, name, etc.)
2. the eventsensor on which this point resides
3. the point number
Points are referenced by a point config index. The point
config index is a string of 2 numbers separated by a period.
It contains all the information necessary for getting a
piece of data off an event sensor within the context of this
analog input point config table ; namely, which EventSensor
and which sensor.
"
::= { eventSensorPointConfig 5 }
--1.3.6.1.4.1.3052.8.2.2.5
esPointConfigAIEntry OBJECT-TYPE
SYNTAX ESPointConfigAnalogInput
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for EventSensor point config analog input table"
INDEX { espcHumidIndexES, espcHumidIndexPoint }
::= { esPointConfigAITable 1 }
--1.3.6.1.4.1.3052.8.2.2.5.1
espcAIIndexES OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that refers to an
EventSensor.
The point config index is a string of 2 numbers separated
by a period. It contains all the information
necessary for getting a piece of data off an event
sensor within the the context of the eventsensor point
config contact closure table; namely, which EventSensor
and which sensor (a.k.a. point).
This object's allowable values are 1 through 16,
and 200. 200 always refers to the EventSensor
inside the unit. 1 through 16 refer to additional
attached EventSensors.
"
::= { esPointConfigAIEntry 1 }
--1.3.6.1.4.1.3052.43.2.2.5.1.1
espcAIIndexPoint OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that delineates which
sensor on the EventSensor.
So this combined with espcAIIndexES (which EventSensor)
uniquely defines each point attached to a unit within the
context of contact closure point configuration."
::= { esPointConfigAIEntry 2 }
--1.3.6.1.4.1.3052.43.2.2.5.1.2
espcAIEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF for this analog input sensor"
::= { esPointConfigAIEntry 3 }
--1.3.6.1.4.1.3052.43.2.2.5.1.3
espcAIName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name for this analog input sensor"
::= { esPointConfigAIEntry 4 }
--1.3.6.1.4.1.3052.43.2.2.5.1.4
espcAIDeadband OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Deadband for this analog input sensor"
::= { esPointConfigAIEntry 5 }
--1.3.6.1.4.1.3052.43.2.2.5.1.5
espcAIVhighValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event threshold (decivolts or tenths of
milliamps) for this analog input sensor"
::= { esPointConfigAIEntry 6 }
--1.3.6.1.4.1.3052.43.2.2.5.1.6
espcAIVhighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event class for this analog input sensor"
::= { esPointConfigAIEntry 8 }
--1.3.6.1.4.1.3052.43.2.2.5.1.8
espcAIHighValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event threshold (decivolts or tenths of
milliamps) for this analog input sensor"
::= { esPointConfigAIEntry 9 }
--1.3.6.1.4.1.3052.43.2.2.5.1.9
espcAIHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event class for this analog input sensor"
::= { esPointConfigAIEntry 12 }
--1.3.6.1.4.1.3052.43.2.2.5.1.12
espcAILowValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event threshold (decivolts or tenths of
milliamps) for this analog input sensor"
::= { esPointConfigAIEntry 16 }
--1.3.6.1.4.1.3052.43.2.2.5.1.16
espcAILowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event class for this analog input sensor"
::= { esPointConfigAIEntry 19 }
--1.3.6.1.4.1.3052.43.2.2.5.1.19
espcAIVlowValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event threshold (decivolts or tenths of
milliamps) for this analog input sensor"
::= { esPointConfigAIEntry 20 }
--1.3.6.1.4.1.3052.43.2.2.5.1.20
espcAIVlowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event class for this analog input sensor"
::= { esPointConfigAIEntry 23 }
--1.3.6.1.4.1.3052.43.2.2.5.1.23
espcAIActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Event actions for this analog input sensor"
::= { esPointConfigAIEntry 24 }
--1.3.6.1.4.1.3052.43.2.2.5.1.24
espcAIConvUnitName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Conversion unit name for this analog input sensor"
::= { esPointConfigAIEntry 25 }
--1.3.6.1.4.1.3052.43.2.2.5.1.25
espcAIConvLowValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Conversion low value for this analog input sensor"
::= { esPointConfigAIEntry 26 }
--1.3.6.1.4.1.3052.43.2.2.5.1.26
espcAIConvLowUnit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Conversion low unit value for this analog input sensor"
::= { esPointConfigAIEntry 27 }
--1.3.6.1.4.1.3052.43.2.2.5.1.27
espcAIConvHighValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Conversion high value for this analog input sensor"
::= { esPointConfigAIEntry 28 }
--1.3.6.1.4.1.3052.43.2.2.5.1.28
espcAIConvHighUnit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Conversion high unit value for this analog input sensor"
::= { esPointConfigAIEntry 29 }
--1.3.6.1.4.1.3052.43.2.2.5.1.29
esPointConfigRelayTable OBJECT-TYPE
SYNTAX SEQUENCE OF ESPointConfigRelay
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes 3 basic attributes of relay
points. A point is a particular sensor on an EventSensor.
The 3 point attributes organizes in this table are:
1. the configuration item (e.g., enable, name, etc.)
2. the eventsensor on which this point resides
3. the point number
Points are referenced by a point config index. The point
config index is a string of 2 numbers separated by a period.
It contains all the information necessary for getting a piece
of data off an event sensor within the context of this
relay point config table ; namely, which
EventSensor and which sensor.
"
::= { eventSensorPointConfig 6 }
--1.3.6.1.4.1.3052.43.2.2.6
esPointConfigRelayEntry OBJECT-TYPE
SYNTAX ESPointConfigRelay
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for EventSensor point config relay table"
INDEX { espcRelayIndexES, espcRelayIndexPoint }
::= { esPointConfigRelayTable 1 }
--1.3.6.1.4.1.3052.43.2.2.6.1
espcRelayIndexES OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that refers to an
EventSensor.
The point config index is a string of 2 numbers separated
by a period. It contains all the information
necessary for getting a piece of data off an event
sensor within the the context of the eventsensor point
config relay table; namely, which EventSensor
and which sensor (a.k.a. point).
This object's allowable values are 1 through 16,
and 200. 200 always refers to the EventSensor
inside the unit. 1 through 16 refer to additional
attached EventSensors.
"
::= { esPointConfigRelayEntry 1 }
--1.3.6.1.4.1.3052.43.2.2.6.1.1
espcRelayIndexPoint OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that delineates which
sensor on the EventSensor.
So this combined with espcRelayIndexES (which EventSensor)
uniquely defines each point attached to a unit within the
context of relay point configuration."
::= { esPointConfigRelayEntry 2 }
--1.3.6.1.4.1.3052.43.2.2.6.1.2
espcRelayEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable for this relay"
::= { esPointConfigRelayEntry 3 }
--1.3.6.1.4.1.3052.43.2.2.6.1.3
espcRelayName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name for this relay"
::= { esPointConfigRelayEntry 4 }
--1.3.6.1.4.1.3052.43.2.2.6.1.4
--***************************************************************************************
--Network Section 2.4
--***************************************************************************************
ipAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet IP address"
::= { ethernet 1 }
--1.3.6.1.4.1.3052.43.2.4.1.1
subnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet subnet mask"
::= { ethernet 2 }
--1.3.6.1.4.1.3052.43.2.4.1.2
router OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet router"
::= { ethernet 3 }
--1.3.6.1.4.1.3052.43.2.4.1.3
-- SNMP
snmpReadCommunity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SNMP read community"
::= { snmp 2 }
--1.3.6.1.4.1.3052.43.2.4.8.2
snmpWriteCommunity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SNMP write community"
::= { snmp 3 }
--1.3.6.1.4.1.3052.43.2.4.8.3
snmpTrapCommunity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SNMP trap community"
::= { snmp 4 }
--1.3.6.1.4.1.3052.43.2.4.8.4
snmpServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActionSNMPConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of network hosts to use for network-based actions"
::= { snmp 6 }
--1.3.6.1.4.1.3052.43.2.8.6
snmpServerEntry OBJECT-TYPE
SYNTAX ActionSNMPConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of network hosts to use for network-based
actions"
INDEX { snmpServerIndex }
::= { snmpServerTable 1 }
--1.3.6.1.4.1.3052.43.2.8.6.1
snmpServerIndex OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of network hosts to use for network-based
actions"
::= { snmpServerEntry 1 }
--1.3.6.1.4.1.3052.43.2.8.6.1.1
snmpServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hostname/IP address used as destination for network-based
action (e.g., trap)"
::= { snmpServerEntry 2 }
--1.3.6.1.4.1.3052.43.2.8.6.1.2
snmpTestTrap OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SNMP trap community"
::= { snmp 7 }
--1.3.6.1.4.1.3052.43.2.4.8.7
-- Email
emailServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SMTP server to which the unit sends email"
::= { email 1 }
--1.3.6.1.4.1.3052.43.2.4.17.1
emailDomain OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Domain to use in recipient address"
::= { email 2 }
--1.3.6.1.4.1.3052.43.2.4.17.2
emailAuthEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable SMTP authentication"
::= { email 3 }
--1.3.6.1.4.1.3052.43.2.4.17.3
emailAuthUsername OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Username for SMTP authentication"
::= { email 4 }
--1.3.6.1.4.1.3052.43.2.4.17.4
emailAuthPassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Password for SMTP authentication"
::= { email 5 }
--1.3.6.1.4.1.3052.43.2.4.17.5
emailTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActionEmailConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of email addresses to use for email actions"
::= { email 6 }
--1.3.6.1.4.1.3052.43.2.4.17.6
emailEntry OBJECT-TYPE
SYNTAX ActionEmailConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of email addresses to use for email actions"
INDEX { emailIndex }
::= { emailTable 1 }
--1.3.6.1.4.1.3052.43.2.4.17.6.1
emailIndex OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of email addresses to use for email actions"
::= { emailEntry 1 }
--1.3.6.1.4.1.3052.43.2.4.17.6.1.1
emailAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"email address"
::= { emailEntry 2 }
--1.3.6.1.4.1.3052.43.2.4.17.6.1.2
emailTestMail OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Password for SMTP authentication"
::= { email 7 }
--1.3.6.1.4.1.3052.43.2.4.17.7
--***************************************************************************************
--dateTime Section 2.8
--***************************************************************************************
date OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Text string for date."
::= { dateTime 1 }
--1.3.6.1.4.1.3052.43.2.8.1
time OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Text string for time."
::= { dateTime 2 }
--1.3.6.1.4.1.3052.43.2.8.2
autodst OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF automatically adjust for Daylight Savings Time"
::= { dateTime 3 }
--1.3.6.1.4.1.3052.43.2.8.3
--***************************************************************************************
--Action Section 2.14
--***************************************************************************************
actionSystemAlertAction OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System Alert Actions are actions that occur when the system needs to alert
the user of something. The only time this occurs currently is a powerup alert."
::= { action 1 }
--1.3.6.1.4.1.3052.43.2.14.1
actionPowerupAlertEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"action Powerup Alert Enable"
::= { action 2 }
--1.3.6.1.4.1.3052.43.2.14.2
actionRTNAlertsEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return to Normal Alerts Enabled"
::= { action 3 }
--1.3.6.1.4.1.3052.43.2.14.3
actionAlarmRepeatFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frequency in minutes of repeats"
::= { action 4 }
--1.3.6.1.4.1.3052.43.2.14.4
--***************************************************************************************
--System Section 2.16
--***************************************************************************************
sysSerial OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Serial Number"
::= { sys 1 }
--1.3.6.1.4.1.3052.43.2.16.1
sysVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Serial Number"
::= { sys 2 }
--1.3.6.1.4.1.3052.43.2.16.2
sysBuild OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Serial Number"
::= { sys 3 }
--1.3.6.1.4.1.3052.43.2.16.3
sysSitename OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Serial Number"
::= { sys 4 }
--1.3.6.1.4.1.3052.43.2.16.4
sysProduct OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Serial Number"
::= { sys 5 }
--1.3.6.1.4.1.3052.43.2.16.5
thisTrapText OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A text string included in all traps"
::= { sys 6 }
--1.3.6.1.4.1.3052.43.2.16.6
--***************************************************************************************
--TABLE DEFINITIONS
--***************************************************************************************
ESPointConfigTemp ::=
SEQUENCE {
espcTempIndexES
Integer32,
espcTempIndexPoint
Integer32,
espcTempEnable
DisplayString,
espcTempName
DisplayString,
espcTempScale
DisplayString,
espcTempDeadband
Integer32,
espcTempVHighTemp
Integer32,
espcTempVHighClass
DisplayString,
espcTempHighTemp
Integer32,
espcTempHighClass
DisplayString,
espcTempLowTemp
Integer32,
espcTempLowClass
DisplayString,
espcTempVLowTemp
Integer32,
espcTempVLowClass
DisplayString,
espcTempActions
DisplayString
}
ESPointConfigCC ::=
SEQUENCE {
espcCCIndexES
Integer32,
espcCCIndexPoint
Integer32,
espcCCEnable
DisplayString,
espcCCName
DisplayString,
espcCCEventState
DisplayString,
espcCCThreshold
Integer32,
espcCCActions
DisplayString,
espcCCEventClass
DisplayString,
espcCCNormalClass
DisplayString,
espcCCAlarmAlias
DisplayString,
espcCCNormalAlias
DisplayString
}
ESPointConfigHumid ::=
SEQUENCE {
espcHumidIndexES
Integer32,
espcHumidIndexPoint
Integer32,
espcHumidEnable
DisplayString,
espcHumidName
DisplayString,
espcHumidDeadband
Integer32,
espcHumidVHighHumid
Integer32,
espcHumidVHighClass
DisplayString,
espcHumidHighHumid
Integer32,
espcHumidHighClass
DisplayString,
espcHumidLowHumid
Integer32,
espcHumidLowClass
DisplayString,
espcHumidVLowHumid
Integer32,
espcHumidVLowClass
DisplayString,
espcHumidActions
DisplayString
}
ESPointConfigAnalogInput ::=
SEQUENCE {
espcAIIndexES
Integer32,
espcAIIndexPoint
Integer32,
espcAIEnable
DisplayString,
espcAIName
DisplayString,
espcAIDeadband
Integer32,
espcAIVhighValue
Integer32,
espcAIVhighClass
DisplayString,
espcAIHighValue
Integer32,
espcAIHighClass
DisplayString,
espcAILowValue
Integer32,
espcAILowClass
DisplayString,
espcAIVlowValue
Integer32,
espcAIVlowClass
DisplayString,
espcAIActions
DisplayString,
espcAIConvUnitName
DisplayString,
espcAIConvLowValue
Integer32,
espcAIConvLowUnit
Integer32,
espcAIConvHighValue
Integer32,
espcAIConvHighUnit
Integer32
}
ESPointConfigRelay::=
SEQUENCE {
espcRelayIndexES
Integer32,
espcRelayIndexPoint
Integer32,
espcRelayEnable
DisplayString,
espcRelayName
DisplayString
}
ActionEmailConfig ::=
SEQUENCE {
emailIndex
Integer32,
emailAddress
DisplayString
}
ESPoint ::=
SEQUENCE {
esIndexES
Integer32,
esIndexPC
Integer32,
esIndexPoint
Integer32,
esPointName
DisplayString,
esPointInEventState
Integer32,
esPointValueInt
Integer32,
esPointValueStr
DisplayString
}
ActionSNMPConfig ::=
SEQUENCE {
snmpServerIndex
Integer32,
snmpServer
IpAddress
}
--***************************************************************************************
--TRAP DEFINITIONS
--***************************************************************************************
s220PowerUpTrap NOTIFICATION-TYPE
OBJECTS { thisTrapText, sysSitename }
STATUS current
DESCRIPTION
"Sent upon System Alert at power up."
::= { s220 20000 }
s220ContactTrap NOTIFICATION-TYPE
OBJECTS { thisTrapText, sysSitename }
STATUS current
DESCRIPTION
"Sent to show a contact is in the alarm state."
::= { s220 20001 }
s220TempTrap NOTIFICATION-TYPE
OBJECTS { thisTrapText, sysSitename }
STATUS current
DESCRIPTION
"Sent to show temperature exceeded threshold."
::= { s220 20010 }
s220HumidTrap NOTIFICATION-TYPE
OBJECTS { thisTrapText, sysSitename }
STATUS current
DESCRIPTION
"Sent to show humidity exceeded threshold"
::= { s220 20020 }
s220TestTrap NOTIFICATION-TYPE
OBJECTS { thisTrapText, sysSitename }
STATUS current
DESCRIPTION
"Sent to test IP route(s) for traps."
::= { s220 22000 }
END