496 lines
18 KiB
Plaintext
496 lines
18 KiB
Plaintext
HNE-DEVICE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
InetAddress,
|
|
InetAddressType
|
|
FROM INET-ADDRESS-MIB
|
|
ifIndex
|
|
FROM IF-MIB
|
|
arrisProdIdRouter
|
|
FROM ARRIS-MIB
|
|
TruthValue, DisplayString, DateAndTime, MacAddress, RowStatus
|
|
FROM SNMPv2-TC;
|
|
|
|
hneMib MODULE-IDENTITY
|
|
LAST-UPDATED "201501140000Z" -- January 14, 2015
|
|
ORGANIZATION "ARRIS Broadband"
|
|
CONTACT-INFO "ARRIS
|
|
Postal: ARRIS Broadband
|
|
3871 Lakefield Drive
|
|
Suite 300
|
|
Suwanee, GA 30024-1242
|
|
U.S.A.
|
|
Phone:
|
|
E-mail: "
|
|
DESCRIPTION
|
|
"This MIB module supplies the basic management objects for Home Networking Extenders.
|
|
This MIB module is only supported by the Wi-Fi Gateway."
|
|
|
|
-- Revision history
|
|
REVISION "201501140000Z" -- January 14, 2015
|
|
DESCRIPTION
|
|
"Changing VLAN table to LAN table (which contains VLAN information) to support HNE extender via TR-181i2 objects only."
|
|
|
|
REVISION "201501070000Z" -- January 7, 2015
|
|
DESCRIPTION
|
|
"First draft of the Home Networking Extender MIB."
|
|
|
|
::= { arrisProdIdRouter 3 }
|
|
|
|
hneMibObjects OBJECT IDENTIFIER ::= { hneMib 1 }
|
|
hneWiFiGWSupport OBJECT IDENTIFIER ::= { hneMibObjects 1 }
|
|
hneLAN OBJECT IDENTIFIER ::= { hneMibObjects 2 }
|
|
|
|
|
|
hneWiFiGWSearch OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Setting this value to 'true' will trigger a M-SEARCH message from the Wi-Fi Gateway."
|
|
::= { hneWiFiGWSupport 1 }
|
|
|
|
hneWiFiGWTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HneWiFiGWEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of Home Networking Extenders that have attempted to connect to the WiFi Gateway."
|
|
::= { hneWiFiGWSupport 2 }
|
|
|
|
hneWiFiGWEntry OBJECT-TYPE
|
|
SYNTAX HneWiFiGWEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in the table of the Home Networking Extender table."
|
|
INDEX { hneWiFiGWIndex }
|
|
::= { hneWiFiGWTable 1 }
|
|
|
|
HneWiFiGWEntry ::=
|
|
SEQUENCE {
|
|
hneWiFiGWIndex Unsigned32,
|
|
hneWiFiGWMACAddr MacAddress,
|
|
hneWiFiGWIPAddrType InetAddressType,
|
|
hneWiFiGWIPAddress InetAddress,
|
|
hneWiFiGWARRISAutoCfgSupport TruthValue,
|
|
hneWiFiGWLocation DisplayString,
|
|
hneWiFiGWManufacturer DisplayString,
|
|
hneWiFiGWModelName DisplayString,
|
|
hneWiFiGWModelNumber DisplayString,
|
|
hneWiFiGWConfigurationId Unsigned32,
|
|
hneWiFiGWLastSynchAttemptTime DateAndTime,
|
|
hneWiFiGWLastSynchAttemptResult INTEGER,
|
|
hneWiFiGWSynchedWithGW TruthValue,
|
|
hneWiFiGWOverride24OutputPower INTEGER,
|
|
hneWiFiGWOverride50OutputPower INTEGER,
|
|
hneWiFiGWOverride24Channel Unsigned32,
|
|
hneWiFiGWOverride50Channel Unsigned32,
|
|
hneWiFiGWOverride24ChannelBW INTEGER,
|
|
hneWiFiGWOverride50ChannelBW INTEGER
|
|
}
|
|
|
|
hneWiFiGWIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the instance of this table row."
|
|
::= { hneWiFiGWEntry 1 }
|
|
|
|
hneWiFiGWMACAddr OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MAC Address of the Home Networking Extender."
|
|
::= { hneWiFiGWEntry 2 }
|
|
|
|
hneWiFiGWIPAddrType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP Address type of the Home Networking Extender."
|
|
::= { hneWiFiGWEntry 3 }
|
|
|
|
hneWiFiGWIPAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP Address of the Home Networking Extender."
|
|
::= { hneWiFiGWEntry 4 }
|
|
|
|
hneWiFiGWARRISAutoCfgSupport OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the GW determined if the Home Networking Extender supports the ARRIS auto-configuration protocol."
|
|
::= { hneWiFiGWEntry 5 }
|
|
|
|
hneWiFiGWLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The URL from the location header field of the NOTIFY/M-SEARCH response of device discovery."
|
|
::= { hneWiFiGWEntry 6 }
|
|
|
|
hneWiFiGWManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer of the Home Networking Extender from the device description during discovery."
|
|
::= { hneWiFiGWEntry 7 }
|
|
|
|
hneWiFiGWModelName OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The model name of the Home Networking Extender from the device description during discovery."
|
|
::= { hneWiFiGWEntry 8 }
|
|
|
|
hneWiFiGWModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The model number of the Home Networking Extender from the device description during discovery."
|
|
::= { hneWiFiGWEntry 9 }
|
|
|
|
hneWiFiGWConfigurationId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..16777215)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Represents the current configuration of the Home Networking Extender."
|
|
::= { hneWiFiGWEntry 10 }
|
|
|
|
hneWiFiGWLastSynchAttemptTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Timestamp of the last synchronization attempt of the Home Networking Extender."
|
|
::= { hneWiFiGWEntry 11 }
|
|
|
|
hneWiFiGWLastSynchAttemptResult OBJECT-TYPE
|
|
SYNTAX INTEGER { uninitialized(-1),
|
|
pass(0),
|
|
failHTTPSSessionEstablishment(1),
|
|
failHTTPSPUT(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the last synchronization case passed or failed with failure reason."
|
|
::= { hneWiFiGWEntry 12 }
|
|
|
|
hneWiFiGWSynchedWithGW OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates if the Home Networking Extender is synchronized with the WiFi Gateway."
|
|
::= { hneWiFiGWEntry 13 }
|
|
|
|
hneWiFiGWOverride24OutputPower OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
gatewayDefault(0),
|
|
percent12(12),
|
|
percent25(25),
|
|
percent50(50),
|
|
percent75(75),
|
|
percent100(100)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the output power relative to the hardware's maximum capability.
|
|
This value is for the 2.4 GHz radio. This value overrides the gateway
|
|
value set via wecbWiFiOutputPower.
|
|
A value of 0 indicates to use the value in the gateway configuration.
|
|
|
|
If the Home Networking Extender does not support one of the provisioned values it should
|
|
implement the closest value that is supported."
|
|
DEFVAL { gatewayDefault }
|
|
::= { hneWiFiGWEntry 14 }
|
|
|
|
hneWiFiGWOverride50OutputPower OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
gatewayDefault(0),
|
|
percent12(12),
|
|
percent25(25),
|
|
percent50(50),
|
|
percent75(75),
|
|
percent100(100)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the output power relative to the hardware's maximum capability.
|
|
This value is for the 5.0 GHz radio. This value overrides the gateway
|
|
value set via wecbWiFi50OutputPower.
|
|
A value of 0 indicates to use the value in the gateway configuration.
|
|
|
|
If the Home Networking Extender does not support one of the provisioned values it should
|
|
implement the closest value that is supported."
|
|
DEFVAL { gatewayDefault }
|
|
::= { hneWiFiGWEntry 15 }
|
|
|
|
hneWiFiGWOverride24Channel OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..216|255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Controls and reflects the current channel number (802.11g) or
|
|
control channel (802.11n).
|
|
|
|
If set to (0), the device will be put in auto-channel mode where it automatically scans
|
|
for the least-crowded channel.
|
|
|
|
For 802.11g cards, available channels are 1-14.
|
|
For 802.11n cards, available channels are 34-216.
|
|
Channel selection is also subject to restrictions based on the selected
|
|
country code.
|
|
|
|
This value overrides the gateway value set via wecbWiFiChannel.
|
|
|
|
A value of 255 indicates there is no override and the gateway setting should be used."
|
|
DEFVAL { 255 }
|
|
::= { hneWiFiGWEntry 16 }
|
|
|
|
hneWiFiGWOverride50Channel OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..216|255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Controls and reflects the current channel number on the 5.0 GHz radio (802.11 a/n).
|
|
|
|
If set to (0), the device will be put in auto-channel mode where it automatically scans
|
|
for the least-crowded channel.
|
|
|
|
Available channels are 34-216.
|
|
Channel selection is also subject to restrictions based on the selected
|
|
country code.
|
|
|
|
This value overrides the gateway value set via wecbWiFi50Channel.
|
|
|
|
A value of 255 indicates there is no override and the gateway setting should be used."
|
|
DEFVAL { 255 }
|
|
::= { hneWiFiGWEntry 17 }
|
|
|
|
hneWiFiGWOverride24ChannelBW OBJECT-TYPE
|
|
SYNTAX INTEGER { gatewayDefault(-2),
|
|
unknown(-1),
|
|
width20MHz(0),
|
|
width40MHz(1),
|
|
width20and40Mhz(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Determines which Band Width that we will be operating in. Either the 20MHz or the 40MHz.
|
|
Note: This is for 802.11n mode only.
|
|
|
|
This value overrides the gateway value set via wecbWiFiChannelBW.
|
|
|
|
A value of -2 indicates to use the value in the gateway configuration."
|
|
DEFVAL { gatewayDefault }
|
|
::= { hneWiFiGWEntry 18 }
|
|
|
|
hneWiFiGWOverride50ChannelBW OBJECT-TYPE
|
|
SYNTAX INTEGER { gatewayDefault(-2),
|
|
unknown(-1),
|
|
width20MHz(0),
|
|
width20and40Mhz(2),
|
|
width20and40and80Mhz(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Determines which Band Width that we will be operating in. Either the 20MHz 40MHz or 80MHz.
|
|
Note: This is for 802.11n mode only.
|
|
|
|
This value overrides the gateway value set via wecbWiFi50ChannelBW.
|
|
|
|
A value of -2 indicates to use the value in the gateway configuration."
|
|
DEFVAL { gatewayDefault }
|
|
::= { hneWiFiGWEntry 19 }
|
|
|
|
hneWiFiGWSupportedTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HneWiFiGWSupportedEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of Home Networking Extenders that are supported by the Wi-Fi GW."
|
|
::= { hneWiFiGWSupport 3 }
|
|
|
|
hneWiFiGWSupportedEntry OBJECT-TYPE
|
|
SYNTAX HneWiFiGWSupportedEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in the table of the supported Home Networking Extender table."
|
|
INDEX { hneWiFiGWSupportedIndex }
|
|
::= { hneWiFiGWSupportedTable 1 }
|
|
|
|
HneWiFiGWSupportedEntry ::=
|
|
SEQUENCE {
|
|
hneWiFiGWSupportedIndex Unsigned32,
|
|
hneWiFiGWSupportedManufacturer DisplayString,
|
|
hneWiFiGWSupportedModelNumber DisplayString,
|
|
hneWiFiGWSupportedRowStatus RowStatus
|
|
}
|
|
|
|
hneWiFiGWSupportedIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the instance of this table row."
|
|
::= { hneWiFiGWSupportedEntry 1 }
|
|
|
|
hneWiFiGWSupportedManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..64))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manufacturer for the supported Home Networking Extenders."
|
|
::= { hneWiFiGWSupportedEntry 2 }
|
|
|
|
hneWiFiGWSupportedModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..64))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Model number for the supported Home Networking Extenders."
|
|
::= { hneWiFiGWSupportedEntry 3 }
|
|
|
|
hneWiFiGWSupportedRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row status for the supported Home Networking Extender entry."
|
|
::= { hneWiFiGWSupportedEntry 4 }
|
|
|
|
hneWiFiGWConfigAttempts OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of allowed configuration mismatch detections
|
|
over the time period hneWiFiGWConfigDuration before
|
|
the GW stops attempting to configure the Home Networking Extender."
|
|
DEFVAL { 10 }
|
|
::= { hneWiFiGWSupport 4 }
|
|
|
|
hneWiFiGWConfigDuration OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The timer period over which the number of configuration
|
|
mismatch detections per hneWiFiGWConfigAttempts is counted."
|
|
DEFVAL { 3600 }
|
|
::= { hneWiFiGWSupport 5 }
|
|
|
|
hneWiFiGWAutoConfigurationEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Enables/disables the ARRIS Home Networking Extender Auto-configuration support."
|
|
DEFVAL { false }
|
|
::= { hneWiFiGWSupport 6 }
|
|
|
|
hneWiFiGWSecurityEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Enables/disables the ARRIS Home Networking Extender security support."
|
|
DEFVAL { true }
|
|
::= { hneWiFiGWSupport 7 }
|
|
|
|
hneLANTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HneLANEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of the LAN interfaces on the Home Networking Extenders connected to
|
|
the WiFi Gateway."
|
|
::= { hneLAN 1 }
|
|
|
|
hneLANEntry OBJECT-TYPE
|
|
SYNTAX HneLANEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in the table of the Home Networking Extender VLAN table."
|
|
INDEX { hneLANIndex, hneLANGWMappingIndex }
|
|
::= { hneLANTable 1 }
|
|
|
|
HneLANEntry ::=
|
|
SEQUENCE {
|
|
hneLANIndex Unsigned32,
|
|
hneLANGWMappingIndex Unsigned32,
|
|
hneLANInterface DisplayString,
|
|
hneLANInterfaceType INTEGER,
|
|
hneLANBridgingMgmtPortInterface DisplayString,
|
|
hneLANVLANID Unsigned32
|
|
}
|
|
|
|
hneLANIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the instance of this table row."
|
|
::= { hneLANEntry 1 }
|
|
|
|
hneLANGWMappingIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value is hneWiFiGWIndex in the hneWiFiGWTable that correlates to the specific Home
|
|
Networking Extender being added to this HNE LAN table on the Gateway."
|
|
::= { hneLANEntry 2 }
|
|
|
|
hneLANInterface OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TR-181i2 Interface object of the specific HNE LAN-side interface."
|
|
::= { hneLANEntry 3 }
|
|
|
|
hneLANInterfaceType OBJECT-TYPE
|
|
SYNTAX INTEGER {radio24Ghz(0),
|
|
radio50Ghz(1),
|
|
radio24GhzSsid(2),
|
|
radio50GhzSsid(3),
|
|
ethernet(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the interface type."
|
|
::= { hneLANEntry 4 }
|
|
|
|
hneLANBridgingMgmtPortInterface OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TR-181i2 Bridge Port Table path name for management port entry for the specific HNE interface.
|
|
Note: This column is not valid for hneLANInterfaceType values of 'radio24Ghz' and 'radio50Ghz'."
|
|
::= { hneLANEntry 5 }
|
|
|
|
hneLANVLANID OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the VLAN ID to be used for this VLAN mapping.
|
|
Note: This column is not valid for hneLANInterfaceType values of 'radio24Ghz' and 'radio50Ghz'."
|
|
::= { hneLANEntry 6 }
|
|
|
|
END
|
|
|