HNE-DEVICE-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32 FROM SNMPv2-SMI InetAddress, InetAddressType FROM INET-ADDRESS-MIB ifIndex FROM IF-MIB arrisProdIdRouter FROM ARRIS-MIB TruthValue, DisplayString, DateAndTime, MacAddress, RowStatus FROM SNMPv2-TC; hneMib MODULE-IDENTITY LAST-UPDATED "201501140000Z" -- January 14, 2015 ORGANIZATION "ARRIS Broadband" CONTACT-INFO "ARRIS Postal: ARRIS Broadband 3871 Lakefield Drive Suite 300 Suwanee, GA 30024-1242 U.S.A. Phone: E-mail: " DESCRIPTION "This MIB module supplies the basic management objects for Home Networking Extenders. This MIB module is only supported by the Wi-Fi Gateway." -- Revision history REVISION "201501140000Z" -- January 14, 2015 DESCRIPTION "Changing VLAN table to LAN table (which contains VLAN information) to support HNE extender via TR-181i2 objects only." REVISION "201501070000Z" -- January 7, 2015 DESCRIPTION "First draft of the Home Networking Extender MIB." ::= { arrisProdIdRouter 3 } hneMibObjects OBJECT IDENTIFIER ::= { hneMib 1 } hneWiFiGWSupport OBJECT IDENTIFIER ::= { hneMibObjects 1 } hneLAN OBJECT IDENTIFIER ::= { hneMibObjects 2 } hneWiFiGWSearch OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this value to 'true' will trigger a M-SEARCH message from the Wi-Fi Gateway." ::= { hneWiFiGWSupport 1 } hneWiFiGWTable OBJECT-TYPE SYNTAX SEQUENCE OF HneWiFiGWEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of Home Networking Extenders that have attempted to connect to the WiFi Gateway." ::= { hneWiFiGWSupport 2 } hneWiFiGWEntry OBJECT-TYPE SYNTAX HneWiFiGWEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the table of the Home Networking Extender table." INDEX { hneWiFiGWIndex } ::= { hneWiFiGWTable 1 } HneWiFiGWEntry ::= SEQUENCE { hneWiFiGWIndex Unsigned32, hneWiFiGWMACAddr MacAddress, hneWiFiGWIPAddrType InetAddressType, hneWiFiGWIPAddress InetAddress, hneWiFiGWARRISAutoCfgSupport TruthValue, hneWiFiGWLocation DisplayString, hneWiFiGWManufacturer DisplayString, hneWiFiGWModelName DisplayString, hneWiFiGWModelNumber DisplayString, hneWiFiGWConfigurationId Unsigned32, hneWiFiGWLastSynchAttemptTime DateAndTime, hneWiFiGWLastSynchAttemptResult INTEGER, hneWiFiGWSynchedWithGW TruthValue, hneWiFiGWOverride24OutputPower INTEGER, hneWiFiGWOverride50OutputPower INTEGER, hneWiFiGWOverride24Channel Unsigned32, hneWiFiGWOverride50Channel Unsigned32, hneWiFiGWOverride24ChannelBW INTEGER, hneWiFiGWOverride50ChannelBW INTEGER } hneWiFiGWIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the instance of this table row." ::= { hneWiFiGWEntry 1 } hneWiFiGWMACAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The MAC Address of the Home Networking Extender." ::= { hneWiFiGWEntry 2 } hneWiFiGWIPAddrType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-only STATUS current DESCRIPTION "IP Address type of the Home Networking Extender." ::= { hneWiFiGWEntry 3 } hneWiFiGWIPAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP Address of the Home Networking Extender." ::= { hneWiFiGWEntry 4 } hneWiFiGWARRISAutoCfgSupport OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if the GW determined if the Home Networking Extender supports the ARRIS auto-configuration protocol." ::= { hneWiFiGWEntry 5 } hneWiFiGWLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The URL from the location header field of the NOTIFY/M-SEARCH response of device discovery." ::= { hneWiFiGWEntry 6 } hneWiFiGWManufacturer OBJECT-TYPE SYNTAX DisplayString(SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The manufacturer of the Home Networking Extender from the device description during discovery." ::= { hneWiFiGWEntry 7 } hneWiFiGWModelName OBJECT-TYPE SYNTAX DisplayString(SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The model name of the Home Networking Extender from the device description during discovery." ::= { hneWiFiGWEntry 8 } hneWiFiGWModelNumber OBJECT-TYPE SYNTAX DisplayString(SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The model number of the Home Networking Extender from the device description during discovery." ::= { hneWiFiGWEntry 9 } hneWiFiGWConfigurationId OBJECT-TYPE SYNTAX Unsigned32 (0..16777215) MAX-ACCESS read-only STATUS current DESCRIPTION "Represents the current configuration of the Home Networking Extender." ::= { hneWiFiGWEntry 10 } hneWiFiGWLastSynchAttemptTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of the last synchronization attempt of the Home Networking Extender." ::= { hneWiFiGWEntry 11 } hneWiFiGWLastSynchAttemptResult OBJECT-TYPE SYNTAX INTEGER { uninitialized(-1), pass(0), failHTTPSSessionEstablishment(1), failHTTPSPUT(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the last synchronization case passed or failed with failure reason." ::= { hneWiFiGWEntry 12 } hneWiFiGWSynchedWithGW OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if the Home Networking Extender is synchronized with the WiFi Gateway." ::= { hneWiFiGWEntry 13 } hneWiFiGWOverride24OutputPower OBJECT-TYPE SYNTAX INTEGER { gatewayDefault(0), percent12(12), percent25(25), percent50(50), percent75(75), percent100(100) } MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the output power relative to the hardware's maximum capability. This value is for the 2.4 GHz radio. This value overrides the gateway value set via wecbWiFiOutputPower. A value of 0 indicates to use the value in the gateway configuration. If the Home Networking Extender does not support one of the provisioned values it should implement the closest value that is supported." DEFVAL { gatewayDefault } ::= { hneWiFiGWEntry 14 } hneWiFiGWOverride50OutputPower OBJECT-TYPE SYNTAX INTEGER { gatewayDefault(0), percent12(12), percent25(25), percent50(50), percent75(75), percent100(100) } MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the output power relative to the hardware's maximum capability. This value is for the 5.0 GHz radio. This value overrides the gateway value set via wecbWiFi50OutputPower. A value of 0 indicates to use the value in the gateway configuration. If the Home Networking Extender does not support one of the provisioned values it should implement the closest value that is supported." DEFVAL { gatewayDefault } ::= { hneWiFiGWEntry 15 } hneWiFiGWOverride24Channel OBJECT-TYPE SYNTAX Unsigned32 (0..216|255) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls and reflects the current channel number (802.11g) or control channel (802.11n). If set to (0), the device will be put in auto-channel mode where it automatically scans for the least-crowded channel. For 802.11g cards, available channels are 1-14. For 802.11n cards, available channels are 34-216. Channel selection is also subject to restrictions based on the selected country code. This value overrides the gateway value set via wecbWiFiChannel. A value of 255 indicates there is no override and the gateway setting should be used." DEFVAL { 255 } ::= { hneWiFiGWEntry 16 } hneWiFiGWOverride50Channel OBJECT-TYPE SYNTAX Unsigned32 (0..216|255) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls and reflects the current channel number on the 5.0 GHz radio (802.11 a/n). If set to (0), the device will be put in auto-channel mode where it automatically scans for the least-crowded channel. Available channels are 34-216. Channel selection is also subject to restrictions based on the selected country code. This value overrides the gateway value set via wecbWiFi50Channel. A value of 255 indicates there is no override and the gateway setting should be used." DEFVAL { 255 } ::= { hneWiFiGWEntry 17 } hneWiFiGWOverride24ChannelBW OBJECT-TYPE SYNTAX INTEGER { gatewayDefault(-2), unknown(-1), width20MHz(0), width40MHz(1), width20and40Mhz(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines which Band Width that we will be operating in. Either the 20MHz or the 40MHz. Note: This is for 802.11n mode only. This value overrides the gateway value set via wecbWiFiChannelBW. A value of -2 indicates to use the value in the gateway configuration." DEFVAL { gatewayDefault } ::= { hneWiFiGWEntry 18 } hneWiFiGWOverride50ChannelBW OBJECT-TYPE SYNTAX INTEGER { gatewayDefault(-2), unknown(-1), width20MHz(0), width20and40Mhz(2), width20and40and80Mhz(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines which Band Width that we will be operating in. Either the 20MHz 40MHz or 80MHz. Note: This is for 802.11n mode only. This value overrides the gateway value set via wecbWiFi50ChannelBW. A value of -2 indicates to use the value in the gateway configuration." DEFVAL { gatewayDefault } ::= { hneWiFiGWEntry 19 } hneWiFiGWSupportedTable OBJECT-TYPE SYNTAX SEQUENCE OF HneWiFiGWSupportedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of Home Networking Extenders that are supported by the Wi-Fi GW." ::= { hneWiFiGWSupport 3 } hneWiFiGWSupportedEntry OBJECT-TYPE SYNTAX HneWiFiGWSupportedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the table of the supported Home Networking Extender table." INDEX { hneWiFiGWSupportedIndex } ::= { hneWiFiGWSupportedTable 1 } HneWiFiGWSupportedEntry ::= SEQUENCE { hneWiFiGWSupportedIndex Unsigned32, hneWiFiGWSupportedManufacturer DisplayString, hneWiFiGWSupportedModelNumber DisplayString, hneWiFiGWSupportedRowStatus RowStatus } hneWiFiGWSupportedIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the instance of this table row." ::= { hneWiFiGWSupportedEntry 1 } hneWiFiGWSupportedManufacturer OBJECT-TYPE SYNTAX DisplayString(SIZE (0..64)) MAX-ACCESS read-create STATUS current DESCRIPTION "Manufacturer for the supported Home Networking Extenders." ::= { hneWiFiGWSupportedEntry 2 } hneWiFiGWSupportedModelNumber OBJECT-TYPE SYNTAX DisplayString(SIZE (0..64)) MAX-ACCESS read-create STATUS current DESCRIPTION "Model number for the supported Home Networking Extenders." ::= { hneWiFiGWSupportedEntry 3 } hneWiFiGWSupportedRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Row status for the supported Home Networking Extender entry." ::= { hneWiFiGWSupportedEntry 4 } hneWiFiGWConfigAttempts OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of allowed configuration mismatch detections over the time period hneWiFiGWConfigDuration before the GW stops attempting to configure the Home Networking Extender." DEFVAL { 10 } ::= { hneWiFiGWSupport 4 } hneWiFiGWConfigDuration OBJECT-TYPE SYNTAX Unsigned32 UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "The timer period over which the number of configuration mismatch detections per hneWiFiGWConfigAttempts is counted." DEFVAL { 3600 } ::= { hneWiFiGWSupport 5 } hneWiFiGWAutoConfigurationEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/disables the ARRIS Home Networking Extender Auto-configuration support." DEFVAL { false } ::= { hneWiFiGWSupport 6 } hneWiFiGWSecurityEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/disables the ARRIS Home Networking Extender security support." DEFVAL { true } ::= { hneWiFiGWSupport 7 } hneLANTable OBJECT-TYPE SYNTAX SEQUENCE OF HneLANEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of the LAN interfaces on the Home Networking Extenders connected to the WiFi Gateway." ::= { hneLAN 1 } hneLANEntry OBJECT-TYPE SYNTAX HneLANEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the table of the Home Networking Extender VLAN table." INDEX { hneLANIndex, hneLANGWMappingIndex } ::= { hneLANTable 1 } HneLANEntry ::= SEQUENCE { hneLANIndex Unsigned32, hneLANGWMappingIndex Unsigned32, hneLANInterface DisplayString, hneLANInterfaceType INTEGER, hneLANBridgingMgmtPortInterface DisplayString, hneLANVLANID Unsigned32 } hneLANIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the instance of this table row." ::= { hneLANEntry 1 } hneLANGWMappingIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The value is hneWiFiGWIndex in the hneWiFiGWTable that correlates to the specific Home Networking Extender being added to this HNE LAN table on the Gateway." ::= { hneLANEntry 2 } hneLANInterface OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "TR-181i2 Interface object of the specific HNE LAN-side interface." ::= { hneLANEntry 3 } hneLANInterfaceType OBJECT-TYPE SYNTAX INTEGER {radio24Ghz(0), radio50Ghz(1), radio24GhzSsid(2), radio50GhzSsid(3), ethernet(4)} MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the interface type." ::= { hneLANEntry 4 } hneLANBridgingMgmtPortInterface OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "TR-181i2 Bridge Port Table path name for management port entry for the specific HNE interface. Note: This column is not valid for hneLANInterfaceType values of 'radio24Ghz' and 'radio50Ghz'." ::= { hneLANEntry 5 } hneLANVLANID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the VLAN ID to be used for this VLAN mapping. Note: This column is not valid for hneLANInterfaceType values of 'radio24Ghz' and 'radio50Ghz'." ::= { hneLANEntry 6 } END