2124 lines
78 KiB
Plaintext
2124 lines
78 KiB
Plaintext
-- Copyright (C) 2008-2016 Aricent. All Rights Reserved
|
|
|
|
-- $Id: fs6374.mib,v 1.3 2017/01/12 12:55:38 siva Exp $
|
|
-- fs6374 Proprietary MIB Definition
|
|
|
|
ARICENT-fs6374-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
enterprises,Unsigned32,Integer32 FROM SNMPv2-SMI
|
|
|
|
TEXTUAL-CONVENTION,
|
|
TruthValue,RowStatus FROM SNMPv2-TC;
|
|
|
|
fs6374MIB MODULE-IDENTITY
|
|
LAST-UPDATED "201209050000Z"
|
|
ORGANIZATION "ARICENT COMMUNICATIONS SOFTWARE"
|
|
CONTACT-INFO "support@aricent.com"
|
|
DESCRIPTION
|
|
"The Proprietary MIB for Loss and Delay measurement based on IETF RFC6374"
|
|
REVISION "201209050000Z"
|
|
DESCRIPTION
|
|
"The Proprietary MIB for Loss and Delay measurement based on IETF RFC6374"
|
|
::= { enterprises aricent-communication-holding-ltd(29601) iss(2) 107 }
|
|
|
|
|
|
-- ******************************************************************
|
|
-- Textual conventions
|
|
-- ******************************************************************
|
|
|
|
FS6374Traps ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the Traps :
|
|
none(0) Dummy Bit
|
|
bTrapUnsupportedVersion(1) Protocol version not supported
|
|
bTrapUnsupportedControlCode(2) Control Code not supported
|
|
bTrapUnsupportedDataFormat(3) Data format specified in query
|
|
not supported
|
|
bTrapConnectionMismatch(4) Session Identifier in response
|
|
does not match the one sent in
|
|
the Query Message
|
|
bTrapUnsupportedMandatoryTLVObject(5) TLV received other than the
|
|
supported
|
|
bTrapUnsupportedTimeStamp(6) Timestamp format not supported
|
|
bTrapResponseTimeout(7) Response Timeout
|
|
bTrapResourceUnavailable(8) MPLS down, BFD session not
|
|
working or mismatch in traffic
|
|
class wrt BFD
|
|
bTrapTestAbort(9) On-demand/ Pro-active test aborted
|
|
explicitly by administrator or by
|
|
LSP/PW down
|
|
bTrapProactiveTestRestart(10) Pro-active test restarted for loss/
|
|
delay/combined Loss-Delay when LSP/PW
|
|
comes up
|
|
bTrapUnsupportedQueryInterval(11) Querier has received response with
|
|
Unsupported Query Interval"
|
|
|
|
SYNTAX BITS{
|
|
none (0),
|
|
bTrapUnsupportedVersion (1),
|
|
bTrapUnsupportedControlCode (2),
|
|
bTrapUnsupportedDataFormat (3),
|
|
bTrapConnectionMismatch (4),
|
|
bTrapUnsupportedMandatoryTLVObject (5),
|
|
bTrapUnsupportedTimeStamp (6),
|
|
bTrapResponseTimeout (7),
|
|
bTrapResourceUnavailable (8),
|
|
bTrapTestAbort(9),
|
|
bTrapProactiveTestRestart(10),
|
|
bTrapUnsupportedQueryInterval(11)
|
|
}
|
|
|
|
FS6374TimeStampFormat ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An enumerated value indicates the timestamp format used for loss and
|
|
delay.
|
|
TimeStampFormatNull(0) Indicates that timestamp field does not
|
|
contain a meaningful timestamp.
|
|
TimeStampFormatSequence(1) Indicates that the timestamp field is to
|
|
be viewed as a simple 64-bit sequence
|
|
number.
|
|
TimeStampFormatNTP(2) This format consists of a 32-bit seconds
|
|
field followed by a 32-bit
|
|
fractional seconds field, so that it can be
|
|
regarded as a fixed-point 64-bit quantity.
|
|
TimeStampFormatIEEE1588(3) This truncated format consists of a 32-bit
|
|
seconds field followed by a 32-bit
|
|
nanoseconds field, and is the same as
|
|
IEEE 1588v1 timestamp format."
|
|
|
|
SYNTAX INTEGER{
|
|
timeStampFormatNull (0),
|
|
timeStampFormatSequence (1),
|
|
timeStampFormatNTP (2),
|
|
timeStampFormatIEEE1588 (3)
|
|
}
|
|
|
|
|
|
Fs6374TransmitStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An enumerated value indicates whether particular transmission can be
|
|
initiated.
|
|
|
|
start(1) To initiate the transmission.
|
|
stop(2) To stop the transmission.
|
|
ready(3) Indicates transmission can be initiated.
|
|
notReady(4) Indicates transmission can not be initiated."
|
|
|
|
SYNTAX INTEGER {
|
|
start (1),
|
|
stop (2),
|
|
ready (3),
|
|
notReady (4)
|
|
}
|
|
|
|
FS6374TimeRepresentation ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "4d:4d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A specification used to represent time stamp.
|
|
|
|
field octets contents range
|
|
----- ------ -------- -----
|
|
1 1-4 seconds 0..4294967295
|
|
2 5-8 nanoseconds/picoseconds 0..0..4294967295 "
|
|
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
|
|
FS6374SuppTimeStampFormat ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Timestamp formats supported by the system.
|
|
tsFormatNTP(1) This format consists of a 32-bit seconds
|
|
field followed by a 32-bit fractional seconds
|
|
(picoseconds) field, so that it can be regarded
|
|
as a fixed-point 64-bit quantity.
|
|
tsFormatIEEE1588(2) This truncated format consists of a 32-bit
|
|
seconds field followed by a 32-bit
|
|
nanoseconds field, and is the same as
|
|
IEEE 1588v1 timestamp format."
|
|
SYNTAX INTEGER{
|
|
tsFormatNTP (1),
|
|
tsFormatIEEE1588 (2)
|
|
}
|
|
---------------------------------------------------
|
|
-- Top level components of this MIB module.
|
|
---------------------------------------------------
|
|
-- Service Config Table --
|
|
fs6374ServiceConfig OBJECT IDENTIFIER ::= { fs6374MIB 1 }
|
|
|
|
|
|
-- Configuration Table for LM/DM --
|
|
fs6374ParamsConfig OBJECT IDENTIFIER ::= { fs6374MIB 2 }
|
|
|
|
-- Buffers for storing the LM and DM calculations --
|
|
fs6374LMBuffer OBJECT IDENTIFIER ::= { fs6374MIB 3 }
|
|
fs6374DMBuffer OBJECT IDENTIFIER ::= { fs6374MIB 4 }
|
|
|
|
-- Statistics for storing the summary of LM and DM calculations --
|
|
fs6374LMStats OBJECT IDENTIFIER ::= { fs6374MIB 5 }
|
|
fs6374DMStats OBJECT IDENTIFIER ::= { fs6374MIB 6 }
|
|
|
|
-- Statistics Table for 6374 --
|
|
fs6374Stats OBJECT IDENTIFIER ::= { fs6374MIB 7 }
|
|
|
|
|
|
-- System Level Config Table --
|
|
fs6374SystemConfig OBJECT IDENTIFIER ::= { fs6374MIB 8 }
|
|
|
|
-- Traps --
|
|
fs6374Notifications OBJECT IDENTIFIER ::= { fs6374MIB 9 }
|
|
|
|
--------------------------------------------------------------------------------------
|
|
--Start of Service Config Table
|
|
--------------------------------------------------------------------------------------
|
|
fs6374ServiceConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Fs6374ServiceConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies a table that holds the service configurations."
|
|
|
|
::= { fs6374ServiceConfig 1 }
|
|
|
|
fs6374ServiceConfigEntry OBJECT-TYPE
|
|
SYNTAX Fs6374ServiceConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies Service Config Entry."
|
|
INDEX { fs6374ContextId,
|
|
fs6374ServiceName }
|
|
::= { fs6374ServiceConfigTable 1 }
|
|
|
|
Fs6374ServiceConfigEntry ::= SEQUENCE {
|
|
fs6374ContextId Unsigned32,
|
|
fs6374ServiceName OCTET STRING,
|
|
fs6374MplsPathType INTEGER,
|
|
fs6374FwdTnlIdOrPwId Unsigned32,
|
|
fs6374RevTnlId Unsigned32,
|
|
fs6374SrcIpAddr OCTET STRING,
|
|
fs6374DestIpAddr OCTET STRING,
|
|
fs6374EncapType INTEGER,
|
|
fs6374TrafficClass INTEGER,
|
|
fs6374RowStatus RowStatus,
|
|
fs6374DyadicMeasurement INTEGER,
|
|
fs6374TSFNegotiation INTEGER,
|
|
fs6374TSNegotiatedFormat Unsigned32,
|
|
fs6374DyadicProactiveRole INTEGER,
|
|
fs6374QueryTransmitRetryCount Unsigned32,
|
|
fs6374SessionIntervalQueryStatus INTEGER,
|
|
fs6374MinReceptionIntervalInMilliseconds Unsigned32
|
|
}
|
|
|
|
fs6374ContextId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the unique identifier to identifies the
|
|
virtual router context.Currently, the implementation supports
|
|
only a single virtual instance of the router."
|
|
::= { fs6374ServiceConfigEntry 1 }
|
|
|
|
fs6374ServiceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE (0..40))
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the unique name of the LSP/PW Service."
|
|
::= { fs6374ServiceConfigEntry 2 }
|
|
|
|
fs6374MplsPathType OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Mpls type which could be Tunnel/LSP or PW."
|
|
|
|
::= { fs6374ServiceConfigEntry 3 }
|
|
|
|
fs6374FwdTnlIdOrPwId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the ID which could be Tunnel Id for
|
|
unidirectional in forward direction or PW Id based on Mpls type."
|
|
::= { fs6374ServiceConfigEntry 4 }
|
|
|
|
fs6374RevTnlId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the ID which is the Tunnel Id for
|
|
unidirectional in reverse direction."
|
|
::= { fs6374ServiceConfigEntry 5 }
|
|
|
|
fs6374SrcIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE (0..40))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the originating IP Address of the
|
|
unidirectional Tunnel or PW."
|
|
::= { fs6374ServiceConfigEntry 6 }
|
|
|
|
fs6374DestIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE (0..40))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the terminating IP Address of the
|
|
unidirectional Tunnel or PW."
|
|
::= { fs6374ServiceConfigEntry 7 }
|
|
|
|
fs6374EncapType OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
withGALHEADER (1),
|
|
withoutGALHEADER (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the header type."
|
|
DEFVAL { withGALHEADER }
|
|
::= { fs6374ServiceConfigEntry 8 }
|
|
|
|
fs6374TrafficClass OBJECT-TYPE
|
|
SYNTAX Integer32(0..7)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the traffic class."
|
|
DEFVAL {0}
|
|
::= { fs6374ServiceConfigEntry 9 }
|
|
|
|
fs6374RowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the status of service configuration row.
|
|
|
|
The writable columns in a row can be changed even if the row
|
|
is active but writable columns cannot be changed if either of
|
|
loss/delay/combined loss-delay test is in-progress.
|
|
Applicable values are CREATE_AND_GO, ACTIVE and DESTROY."
|
|
::= { fs6374ServiceConfigEntry 10 }
|
|
|
|
fs6374DyadicMeasurement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Dyadic Measurement status as
|
|
enabled or disabled."
|
|
DEFVAL { disable }
|
|
::= { fs6374ServiceConfigEntry 11 }
|
|
|
|
fs6374TSFNegotiation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Timestamp Format Negotiation status as
|
|
enabled or disabled.
|
|
This configuration is applicable only for Non-dyadic Two-way DM
|
|
and Combined LMDM and value should be configured at querier end.
|
|
When it is enabled, if the QTF and RTF are different, the
|
|
responder will fill Preferred Timestamp format based on the
|
|
supported timestamp 'fs6374TSFormatSupported' and Timestamp format
|
|
configured for DM/combined LMDM, the querier will change the
|
|
format if responder's format is supported by querier."
|
|
DEFVAL { disabled }
|
|
::= { fs6374ServiceConfigEntry 12 }
|
|
|
|
fs6374TSNegotiatedFormat OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Negotiated Time Stamp Format of the
|
|
querier. This negotiated format is applicable only for
|
|
Non-dyadic Two-way DM and Combined LMDM.
|
|
The negotiated timestamp format can be either
|
|
timeStampFormatNTP (2) or
|
|
timeStampFormatIEEE1588 (3).
|
|
The negotiated Timestamp format will be used as the timestamp for
|
|
delay measurement process in both querier and responder.
|
|
This object displays the negotiated format only if
|
|
`fs6374TSFNegotiation` is enabled or else timeStampFormatIEEE1588
|
|
will be displayed as negotiated format."
|
|
::= { fs6374ServiceConfigEntry 13 }
|
|
|
|
fs6374DyadicProactiveRole OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
active (1),
|
|
passive (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Dyadic Measurement Proactive Role
|
|
status as active or passive.
|
|
If configured as passive, dyadic will initiated only after
|
|
initiated from active on peer end.
|
|
If configured as active, dyadic will be initiated."
|
|
DEFVAL { passive }
|
|
::= { fs6374ServiceConfigEntry 14 }
|
|
|
|
fs6374QueryTransmitRetryCount OBJECT-TYPE
|
|
SYNTAX Unsigned32(3..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the maximum number of retries of queries by a session
|
|
when querier is not getting response from the responder.
|
|
This object is used for congestion control at querier for outgoing packets."
|
|
DEFVAL { 25 }
|
|
::= { fs6374ServiceConfigEntry 15 }
|
|
|
|
fs6374SessionIntervalQueryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Session Interval Query status as
|
|
enabled or disabled. This is applicable only for sending SQI TLV.
|
|
Whereas for responding to SQI TLV this is not mandatory to be enabled."
|
|
DEFVAL { enable }
|
|
::= { fs6374ServiceConfigEntry 16 }
|
|
|
|
|
|
fs6374MinReceptionIntervalInMilliseconds OBJECT-TYPE
|
|
SYNTAX Unsigned32(100..10000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the minimum time interval between two query
|
|
packets at which the service is ready to receive the packets.
|
|
This object is used for congestion control and rate limit the incoming
|
|
queries at responder. This will be different from Transmit query interval
|
|
time of a service. By default both transmit query interval and
|
|
receive query interval are same. This has a granularity of 10 milliseconds."
|
|
DEFVAL { 100 }
|
|
::= { fs6374ServiceConfigEntry 17 }
|
|
--------------------------------------------------------------------------------------
|
|
--End of Service Config Table
|
|
--------------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------------
|
|
--Start of Configuration Table for LM/DM
|
|
--------------------------------------------------------------------------------------
|
|
fs6374ParamsConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Fs6374ParamsConfigTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies all the configurations related to LM and DM
|
|
as per virtual context of the router."
|
|
::= { fs6374ParamsConfig 1 }
|
|
|
|
fs6374ParamsConfigTableEntry OBJECT-TYPE
|
|
SYNTAX Fs6374ParamsConfigTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies per virtual context LM and DM configuration parameters.
|
|
An entry in this table is created when a virtual context
|
|
is created."
|
|
INDEX { fs6374ContextId,
|
|
fs6374ServiceName }
|
|
::= { fs6374ParamsConfigTable 1 }
|
|
|
|
Fs6374ParamsConfigTableEntry ::= SEQUENCE {
|
|
fs6374LMType INTEGER,
|
|
fs6374LMMethod INTEGER,
|
|
fs6374LMMode INTEGER,
|
|
fs6374LMNoOfMessages Unsigned32,
|
|
fs6374LMTimeIntervalInMilliseconds Unsigned32,
|
|
fs6374LMTimeStampFormat FS6374TimeStampFormat,
|
|
fs6374LMTransmitStatus Fs6374TransmitStatus,
|
|
fs6374DMType INTEGER,
|
|
fs6374DMMode INTEGER,
|
|
fs6374DMTimeIntervalInMilliseconds Unsigned32,
|
|
fs6374DMNoOfMessages Unsigned32,
|
|
fs6374DMTimeStampFormat FS6374TimeStampFormat,
|
|
fs6374DMTransmitStatus Fs6374TransmitStatus,
|
|
fs6374CmbLMDMType INTEGER,
|
|
fs6374CmbLMDMMethod INTEGER,
|
|
fs6374CmbLMDMMode INTEGER,
|
|
fs6374CmbLMDMNoOfMessages Unsigned32,
|
|
fs6374CmbLMDMTimeIntervalInMilliseconds Unsigned32,
|
|
fs6374CmbLMDMTimeStampFormat FS6374TimeStampFormat,
|
|
fs6374CmbLMDMTransmitStatus Fs6374TransmitStatus,
|
|
fs6374DMPaddingSize Unsigned32,
|
|
fs6374CmbLMDMPaddingSize Unsigned32
|
|
}
|
|
|
|
fs6374LMType OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
oneway (1),
|
|
twoway (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the type of LM calculation.
|
|
|
|
oneway(1) Indicates that calculation of LM will be in one way.
|
|
twoway(2) Indicates that calculation of LM will be in two way.
|
|
This object cannot be modified when fs6374LMTransmitStatus
|
|
is `notReady`."
|
|
DEFVAL { twoway }
|
|
::= { fs6374ParamsConfigTableEntry 1 }
|
|
|
|
fs6374LMMethod OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
direct (1),
|
|
inferred (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the mode in which LM feature will work.
|
|
|
|
direct(1) Indicates that the LM feature will work in
|
|
Direct Method.
|
|
inferred(2) Indicates that LM feature will work in
|
|
Inferred Method.
|
|
This object cannot be modified when fs6374LMTransmitStatus
|
|
is `notReady`."
|
|
|
|
DEFVAL { inferred }
|
|
::= { fs6374ParamsConfigTableEntry 2 }
|
|
|
|
fs6374LMMode OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
onDemand (1),
|
|
proActive (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the method of LM calculation.
|
|
|
|
onDemand(1) Indicates that calculation of LM will be
|
|
done based on user request.
|
|
proActive(2) Indicates that calculation of LM will be
|
|
done proactively.
|
|
when this object is set as pro-active and based on the object
|
|
fs6374LMType and fs6374LMTransmitStatus test will be started
|
|
immediately."
|
|
DEFVAL { onDemand }
|
|
::= { fs6374ParamsConfigTableEntry 3 }
|
|
|
|
|
|
fs6374LMNoOfMessages OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..1000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of queries to be sent in a session
|
|
when method for LM calculation is Ondemand.
|
|
This object cannot be modified when fs6374LMTransmitStatus
|
|
is `notReady`."
|
|
DEFVAL { 10 }
|
|
::= { fs6374ParamsConfigTableEntry 4 }
|
|
|
|
fs6374LMTimeIntervalInMilliseconds OBJECT-TYPE
|
|
SYNTAX Unsigned32(100..10000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the time interval between two query packets
|
|
for LM with the granularity of 10milliseconds.
|
|
This object cannot be modified when fs6374LMTransmitStatus
|
|
is `notReady`."
|
|
DEFVAL { 1000 }
|
|
::= { fs6374ParamsConfigTableEntry 5 }
|
|
|
|
|
|
fs6374LMTimeStampFormat OBJECT-TYPE
|
|
SYNTAX FS6374TimeStampFormat
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the preferred timestamp format
|
|
which will be used for LM.
|
|
The below specified timestamp formats are supported for
|
|
Loss Measurement but now, time stamp format NTP is not support.
|
|
timeStampFormatNull (0),
|
|
timeStampFormatSequence (1),
|
|
timeStampFormatNTP (2),
|
|
timeStampFormatIEEE1588 (3).
|
|
This object cannot be modified if fs6374LMMTransmitStatus
|
|
is `notReady`."
|
|
|
|
DEFVAL { timeStampFormatIEEE1588 }
|
|
::= { fs6374ParamsConfigTableEntry 6 }
|
|
|
|
fs6374LMTransmitStatus OBJECT-TYPE
|
|
SYNTAX Fs6374TransmitStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the status of loss transmit."
|
|
DEFVAL { ready }
|
|
::= { fs6374ParamsConfigTableEntry 7 }
|
|
|
|
|
|
fs6374DMType OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
oneway (1),
|
|
twoway (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the type of DM calculation.
|
|
|
|
oneway(1) Indicates that calculation of DM will be one-way.
|
|
twoway(2) Indicates that calculation of DM will be two-way.
|
|
This object cannot be modified when fs6374DMTransmitStatus
|
|
is `notReady`."
|
|
DEFVAL { twoway }
|
|
::= { fs6374ParamsConfigTableEntry 8 }
|
|
|
|
|
|
fs6374DMMode OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
onDemand (1),
|
|
proActive (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the method of DM calculation.
|
|
|
|
onDemand(1) Indicates that calculation of DM will be done
|
|
based on user request.
|
|
proActive(2) Indicates that calculation of DM will be done
|
|
proactively.
|
|
when this object is set as proactive and based on the object
|
|
fs6374DMType and fs6374DMTransmitStatus test will be started
|
|
immediately."
|
|
DEFVAL { onDemand }
|
|
::= { fs6374ParamsConfigTableEntry 9 }
|
|
|
|
|
|
fs6374DMTimeIntervalInMilliseconds OBJECT-TYPE
|
|
SYNTAX Unsigned32(100..10000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the time interval between two query packets
|
|
for DM with the granularity of 10milliseconds.
|
|
This object cannot be modified when fs6374DMTransmitStatus
|
|
is `notReady`."
|
|
DEFVAL { 1000 }
|
|
::= { fs6374ParamsConfigTableEntry 10 }
|
|
|
|
fs6374DMNoOfMessages OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..1000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of queries to be sent in a session
|
|
when method for LM calculation is Ondemand.
|
|
This object cannot be modified when fs6374DMTransmitStatus
|
|
is `notReady`."
|
|
DEFVAL { 10 }
|
|
::= { fs6374ParamsConfigTableEntry 11 }
|
|
|
|
fs6374DMTimeStampFormat OBJECT-TYPE
|
|
SYNTAX FS6374TimeStampFormat
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the preferred timestamp format
|
|
which will be used for delay measurement calculation.
|
|
The below specified timestamp formats are supported for
|
|
Delay Measurement but now, time stamp format NTP is not support.
|
|
timeStampFormatNTP (2),
|
|
timeStampFormatIEEE1588 (3).
|
|
This object cannot be modified when fs6374DMTransmitStatus
|
|
is `notReady`."
|
|
DEFVAL { timeStampFormatIEEE1588 }
|
|
::= { fs6374ParamsConfigTableEntry 12 }
|
|
|
|
fs6374DMTransmitStatus OBJECT-TYPE
|
|
SYNTAX Fs6374TransmitStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the status of delay transmit and
|
|
an Enumerated value set to 'start' to initiate 1DM or
|
|
DMM transmission and 'stop' to stop 1DM or DMM transmission.
|
|
The values 'ready' and 'notReady' indicate whether
|
|
1DM or DMM can be initiated or not.
|
|
|
|
Note: User can not set to 'ready' or 'notReady'."
|
|
DEFVAL { ready }
|
|
::= { fs6374ParamsConfigTableEntry 13 }
|
|
|
|
fs6374CmbLMDMType OBJECT-TYPE
|
|
SYNTAX INTEGER { oneway(1), twoway(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the combined LMDM calculation type
|
|
provided by the service. The following two types are
|
|
possible:
|
|
oneway - Indicates that calculation of combined LMDM will be
|
|
in one way.
|
|
twoway - Indicates that calculation of combined LMDM will be
|
|
in two way.
|
|
The combined LMDM calculation type cannot be modified when the
|
|
fs6374CmbLMDMTransmitStatus is `notReady`."
|
|
DEFVAL { twoway }
|
|
::= { fs6374ParamsConfigTableEntry 14 }
|
|
|
|
fs6374CmbLMDMMethod OBJECT-TYPE
|
|
SYNTAX INTEGER { direct(1), inferred(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the combined LMDM calculation method
|
|
provided by the service. The following two methods are
|
|
possible:
|
|
direct - Indicates that the combined LMDM feature will work
|
|
in Direct Method.
|
|
inferred - Indicates that the combined LMDM feature will work
|
|
in Inferred Method.
|
|
The combined LMDM calculation method cannot be modified when the
|
|
fs6374CmbLMDMTransmitStatus is `notReady`."
|
|
DEFVAL { inferred }
|
|
::= { fs6374ParamsConfigTableEntry 15 }
|
|
|
|
fs6374CmbLMDMMode OBJECT-TYPE
|
|
SYNTAX INTEGER { onDemand(1), proActive(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the combined LMDM calculation mode
|
|
provided by the service. The following two modes are
|
|
possible:
|
|
onDemand - Indicates that calculation of combined LMDM will
|
|
be done based on user request.
|
|
proActive - Indicates that calculation of combined LMDM will
|
|
be done proactively.
|
|
|
|
when this object is set as pro-active mode and based on the object
|
|
fs6374CmbLMDMType and fs6374CmbLMDMTransmitStatus test will be
|
|
started immediately.
|
|
|
|
The combined LMDM calculation mode cannot be modified when the
|
|
fs6374CmbLMDMTransmitStatus is `notReady`."
|
|
DEFVAL { onDemand }
|
|
::= { fs6374ParamsConfigTableEntry 16 }
|
|
|
|
fs6374CmbLMDMNoOfMessages OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..1000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of combined LMDM queries to be
|
|
sent in a session when method for LM calculation is `Ondemand`.
|
|
This object cannot be modified when the fs6374CmbLMDMTransmitStatus
|
|
is `notReady`."
|
|
DEFVAL { 10 }
|
|
::= { fs6374ParamsConfigTableEntry 17 }
|
|
|
|
fs6374CmbLMDMTimeIntervalInMilliseconds OBJECT-TYPE
|
|
SYNTAX Unsigned32(100..10000)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the time interval between two combined
|
|
LMDM query packets for LM with the granularity of 10 milliseconds.
|
|
This object cannot be modified when fs6374CmbLMDMTransmitStatus
|
|
is `notReady`."
|
|
DEFVAL { 1000 }
|
|
::= { fs6374ParamsConfigTableEntry 18 }
|
|
|
|
fs6374CmbLMDMTimeStampFormat OBJECT-TYPE
|
|
SYNTAX FS6374TimeStampFormat
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the preferred timestamp format
|
|
which will be used for combined LMDM calculation.
|
|
The below specified timestamp formats are supported for
|
|
Combined loss and delay Measurement but now, time stamp
|
|
format NTP is not support.
|
|
timeStampFormatNTP (2),
|
|
timeStampFormatIEEE1588 (3).
|
|
This object cannot be modified when fs6374CmbLMDMTransmitStatus
|
|
is `notReady`."
|
|
DEFVAL { timeStampFormatIEEE1588 }
|
|
::= { fs6374ParamsConfigTableEntry 19 }
|
|
|
|
fs6374CmbLMDMTransmitStatus OBJECT-TYPE
|
|
SYNTAX Fs6374TransmitStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies combined LMDM calculation transmission
|
|
status. The following two values are possible to set by
|
|
administrator:
|
|
start - To initiate combined LMDM transmission.
|
|
stop - To stop the combined LMDM transmission.
|
|
The values 'ready' and 'notReady' indicate whether combined LMDM
|
|
can be initiated or not.
|
|
The value `notReady` specifies that particular transmission is
|
|
already On-going for that service.
|
|
The Value `ready` specifies that particular transmission can be
|
|
initiated for the service.
|
|
|
|
Note: User can not set to 'ready' or 'notReady'."
|
|
DEFVAL { ready }
|
|
::= { fs6374ParamsConfigTableEntry 20 }
|
|
|
|
fs6374DMPaddingSize OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..9000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the size of the pattern to be included in
|
|
the Padding TLV of DM message.
|
|
|
|
This configuration is applicable only for Non-dyadic DM
|
|
Measurement.
|
|
|
|
Maximum frame size suggested by RFC6374 for Padding TLV is
|
|
9000 bytes. Based on the interface MTU, the maximum frame size
|
|
of DM padding TLV size can be chosen.
|
|
|
|
The TLV value field in PaddingTLV will have maximum of 255 bytes.
|
|
When the fs6374DMPaddingSize is configured with more than
|
|
255 bytes then total size will be split across multiple TLVs.
|
|
|
|
Default value of padding pattern is updated as zero for the
|
|
size specified by this object. If the object is configured
|
|
with the value as `zero` then padding TLV will not be included.
|
|
|
|
There are two types of padding TLV are specified in RFC6374
|
|
section 3.5 but the padding TLV type 0 - Copy in response
|
|
is supported.
|
|
|
|
This object cannot be modified when fs6374DMTransmitStatus
|
|
is `notReady`."
|
|
DEFVAL { 0 }
|
|
::= { fs6374ParamsConfigTableEntry 21 }
|
|
|
|
fs6374CmbLMDMPaddingSize OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..9000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the size of the pattern to be included in
|
|
the Padding TLV of Combined LMDM message.
|
|
|
|
This configuration is applicable only for Non-dyadic
|
|
Combined LMDM Measurement.
|
|
|
|
Maximum frame size suggested by RFC6374 for Padding TLV is
|
|
9000 bytes. Based on the interface MTU, the maximum frame size
|
|
of Combined LMDM padding TLV size can be chosen.
|
|
|
|
The TLV value field in PaddingTLV will have maximum of 255 bytes.
|
|
When the fs6374CmbLMDMPaddingSize is configured with more than
|
|
255 bytes then total size will be split across multiple TLVs.
|
|
|
|
Default value of padding pattern is updated as zero for the
|
|
size specified by this object. If the object is configured
|
|
with the value as `zero` then padding TLV will not be included.
|
|
|
|
There are two types of padding TLV are specified in RFC6374
|
|
section 3.5 but the padding TLV type 0 - Copy in
|
|
response is supported.
|
|
|
|
This object cannot be modified when fs6374CmbLMDMTransmitStatus
|
|
is `notReady`."
|
|
DEFVAL { 0 }
|
|
::= { fs6374ParamsConfigTableEntry 22 }
|
|
|
|
--------------------------------------------------------------------------------------
|
|
-- End of Configuration Table for LM/DM
|
|
--------------------------------------------------------------------------------------
|
|
|
|
--------------------------------------------------------------------------------------
|
|
-- Start of Buffers for storing the LM calculations
|
|
--------------------------------------------------------------------------------------
|
|
fs6374LMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Fs6374LMTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the table that holds the detailed buffer
|
|
information for Loss measurement measured at various time
|
|
intervals."
|
|
::= { fs6374LMBuffer 1 }
|
|
|
|
fs6374LMTableEntry OBJECT-TYPE
|
|
SYNTAX Fs6374LMTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Loss statistics table entry."
|
|
INDEX { fs6374ContextId,
|
|
fs6374ServiceName,
|
|
fs6374LMSessionId,
|
|
fs6374LMSeqNum
|
|
}
|
|
::= { fs6374LMTable 1 }
|
|
|
|
Fs6374LMTableEntry ::= SEQUENCE {
|
|
fs6374LMSessionId Unsigned32,
|
|
fs6374LMSeqNum Unsigned32,
|
|
fs6374LMTxLossAtSenderEnd Unsigned32,
|
|
fs6374LMRxLossAtSenderEnd Unsigned32,
|
|
fs6374LMRxLossAtReceiverEnd Unsigned32,
|
|
fs6374LMMeasurementTimeTakenInMilliseconds FS6374TimeRepresentation,
|
|
fs6374LMTransmitResultOK TruthValue,
|
|
fs6374LMTestPktsCount Unsigned32
|
|
}
|
|
|
|
fs6374LMSessionId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Loss measurement session id."
|
|
::= { fs6374LMTableEntry 1 }
|
|
|
|
fs6374LMSeqNum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the locally maintained sequence number of
|
|
loss Entries."
|
|
::= { fs6374LMTableEntry 2 }
|
|
|
|
fs6374LMTxLossAtSenderEnd OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the transmit loss value which is calculated at
|
|
sender end.This value is populated for Two-way measurement."
|
|
::= { fs6374LMTableEntry 3 }
|
|
|
|
fs6374LMRxLossAtSenderEnd OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the receiver loss value which is calculated at
|
|
sender end. This value is populated for Two-way measurement."
|
|
::= { fs6374LMTableEntry 4 }
|
|
|
|
fs6374LMRxLossAtReceiverEnd OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the receiver loss value which is calculated at
|
|
sender end. This value is populated for one-way measurement."
|
|
::= { fs6374LMTableEntry 5 }
|
|
|
|
fs6374LMMeasurementTimeTakenInMilliseconds OBJECT-TYPE
|
|
SYNTAX FS6374TimeRepresentation
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the time taken to measure loss."
|
|
::= { fs6374LMTableEntry 6 }
|
|
|
|
fs6374LMTransmitResultOK OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the result of the operation:
|
|
- true The Loss measurement Message (1LM or LMM) will be
|
|
(or has been) sent.
|
|
- false The Loss measurement Message (1LM or LMM) will not be
|
|
sent."
|
|
DEFVAL { true }
|
|
::= { fs6374LMTableEntry 7 }
|
|
|
|
fs6374LMTestPktsCount OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the total number of test PDUs transmitted at sender end for each transaction. This value is populated for measurement.
|
|
"
|
|
::= { fs6374LMTableEntry 8 }
|
|
|
|
|
|
--------------------------------------------------------------------------------------
|
|
--End of Buffers for storing the LM calculations
|
|
--------------------------------------------------------------------------------------
|
|
|
|
--------------------------------------------------------------------------------------
|
|
--Start of Buffers for storing the DM calculations
|
|
--------------------------------------------------------------------------------------
|
|
fs6374DMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Fs6374DMTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the table that contains the detailed buffer
|
|
information for delay measured at various times."
|
|
::= { fs6374DMBuffer 1 }
|
|
|
|
fs6374DMTableEntry OBJECT-TYPE
|
|
SYNTAX Fs6374DMTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object specifies the detailed delay buffer table entry."
|
|
INDEX { fs6374ContextId,
|
|
fs6374ServiceName,
|
|
fs6374DMSessionId,
|
|
fs6374DMSeqNum
|
|
}
|
|
::= { fs6374DMTable 1 }
|
|
|
|
Fs6374DMTableEntry ::= SEQUENCE {
|
|
fs6374DMSessionId Unsigned32,
|
|
fs6374DMSeqNum Unsigned32,
|
|
fs6374DMDelayValue FS6374TimeRepresentation,
|
|
fs6374DMRTDelayValue FS6374TimeRepresentation,
|
|
fs6374DMIPDV FS6374TimeRepresentation,
|
|
fs6374DMPDV FS6374TimeRepresentation,
|
|
fs6374DMTransmitResultOK TruthValue
|
|
}
|
|
|
|
fs6374DMSessionId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the delay measurement session id."
|
|
::= { fs6374DMTableEntry 1 }
|
|
|
|
fs6374DMSeqNum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the locally maintained sequence number of
|
|
delay entries."
|
|
::= { fs6374DMTableEntry 2 }
|
|
|
|
fs6374DMDelayValue OBJECT-TYPE
|
|
SYNTAX FS6374TimeRepresentation
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the measured delay value."
|
|
::= { fs6374DMTableEntry 3 }
|
|
|
|
fs6374DMRTDelayValue OBJECT-TYPE
|
|
SYNTAX FS6374TimeRepresentation
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the measured round trip delay value."
|
|
::= { fs6374DMTableEntry 4 }
|
|
|
|
fs6374DMIPDV OBJECT-TYPE
|
|
SYNTAX FS6374TimeRepresentation
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Inter frame delay variation (IFDV),
|
|
calculated with respect to current transaction."
|
|
::= { fs6374DMTableEntry 5 }
|
|
|
|
fs6374DMPDV OBJECT-TYPE
|
|
SYNTAX FS6374TimeRepresentation
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Frame delay variation (IFDV), calculated
|
|
with respect to current transaction."
|
|
::= { fs6374DMTableEntry 6 }
|
|
|
|
fs6374DMTransmitResultOK OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the result of the operation:
|
|
|
|
- true The Delay measurement Message (1DM or DMM) will be
|
|
(or has been) sent.
|
|
- false The Delay measurement Message (1DM or DMM) will not
|
|
be sent."
|
|
DEFVAL { true }
|
|
::= { fs6374DMTableEntry 7 }
|
|
|
|
--------------------------------------------------------------------------------------
|
|
--End of Buffers for storing the DM calculations
|
|
--------------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------------
|
|
--Start of Buffers for storing the summary of LM calculations
|
|
--------------------------------------------------------------------------------------
|
|
fs6374LMStatsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Fs6374LMStatsTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the table that contains the summary of Loss
|
|
information based on Service name and Session Id."
|
|
::= { fs6374LMStats 1 }
|
|
|
|
fs6374LMStatsTableEntry OBJECT-TYPE
|
|
SYNTAX Fs6374LMStatsTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object specifies the loss Statistics table entry."
|
|
INDEX { fs6374ContextId,
|
|
fs6374ServiceName,
|
|
fs6374LMSessionId
|
|
}
|
|
::= { fs6374LMStatsTable 1 }
|
|
|
|
Fs6374LMStatsTableEntry ::= SEQUENCE {
|
|
fs6374LMStatsMplsType INTEGER,
|
|
fs6374LMStatsFwdTnlIdOrPwId Unsigned32,
|
|
fs6374LMStatsRevTnlId Unsigned32,
|
|
fs6374LMStatsSrcIpAddr OCTET STRING,
|
|
fs6374LMStatsDestIpAddr OCTET STRING,
|
|
fs6374LMStatsTrafficClass INTEGER,
|
|
fs6374LMStatsMode INTEGER,
|
|
fs6374LMStatsMethod INTEGER,
|
|
fs6374LMStatsType INTEGER,
|
|
fs6374LMStatsTimeStampFormat FS6374TimeStampFormat,
|
|
fs6374LMStatsStartTime Unsigned32,
|
|
fs6374LMStatsFarEndLossMin Unsigned32,
|
|
fs6374LMStatsFarEndLossMax Unsigned32,
|
|
fs6374LMStatsFarEndLossAvg Unsigned32,
|
|
fs6374LMStatsNearEndLossMin Unsigned32,
|
|
fs6374LMStatsNearEndLossMax Unsigned32,
|
|
fs6374LMStatsNearEndLossAvg Unsigned32,
|
|
fs6374LMStatsTxPktCount Unsigned32,
|
|
fs6374LMStatsRxPktCount Unsigned32,
|
|
fs6374LMStatsThroughputpercent OCTET STRING,
|
|
fs6374LMStatsResponseErrors Unsigned32,
|
|
fs6374LMStatsResponseTimeout Unsigned32,
|
|
fs6374LMStatsMeasurementOnGoing INTEGER,
|
|
fs6374LMDyadicMeasurement INTEGER,
|
|
fs6374LMRemoteSessionId Unsigned32,
|
|
fs6374LMDyadicProactiveRole INTEGER,
|
|
fs6374IsLMBufferSQIEnabled TruthValue
|
|
}
|
|
|
|
fs6374LMStatsMplsType OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Mpls type which could be Tunnel/Lsp
|
|
or PW."
|
|
::= { fs6374LMStatsTableEntry 1 }
|
|
|
|
fs6374LMStatsFwdTnlIdOrPwId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Tunnel Id for unidirectional in forward
|
|
direction or PW Id based on Mpls type."
|
|
::= { fs6374LMStatsTableEntry 2 }
|
|
|
|
fs6374LMStatsRevTnlId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Tunnel Id for unidirectional in
|
|
reverse direction."
|
|
::= { fs6374LMStatsTableEntry 3 }
|
|
|
|
fs6374LMStatsSrcIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE (0..40))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the source IP Address."
|
|
::= { fs6374LMStatsTableEntry 4 }
|
|
|
|
fs6374LMStatsDestIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE (0..40))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the destination IP Address."
|
|
::= { fs6374LMStatsTableEntry 5 }
|
|
|
|
fs6374LMStatsTrafficClass OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the traffic class."
|
|
::= { fs6374LMStatsTableEntry 6 }
|
|
|
|
|
|
fs6374LMStatsMode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the method (ondemand or proactive) used for LM.
|
|
This is not applicable for one-way type."
|
|
::= { fs6374LMStatsTableEntry 7 }
|
|
|
|
fs6374LMStatsMethod OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the method (inferred or direct) used for LM."
|
|
::= { fs6374LMStatsTableEntry 8 }
|
|
|
|
fs6374LMStatsType OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the type (oneWay or twoWay) used for LM."
|
|
::= { fs6374LMStatsTableEntry 9 }
|
|
|
|
fs6374LMStatsTimeStampFormat OBJECT-TYPE
|
|
SYNTAX FS6374TimeStampFormat
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the value of timestamp format for the LM."
|
|
::= { fs6374LMStatsTableEntry 10 }
|
|
|
|
fs6374LMStatsStartTime OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the time at which loss measurement starts."
|
|
::= { fs6374LMStatsTableEntry 11 }
|
|
|
|
fs6374LMStatsFarEndLossMin OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the minimum value of far-end loss."
|
|
::= { fs6374LMStatsTableEntry 12 }
|
|
|
|
fs6374LMStatsFarEndLossMax OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the maxmium value of far-end loss."
|
|
::= { fs6374LMStatsTableEntry 13 }
|
|
|
|
fs6374LMStatsFarEndLossAvg OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the average of the far-end loss measured
|
|
for a transaction."
|
|
::= { fs6374LMStatsTableEntry 14 }
|
|
|
|
fs6374LMStatsNearEndLossMin OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the minimum value of near-end loss."
|
|
::= { fs6374LMStatsTableEntry 15 }
|
|
|
|
fs6374LMStatsNearEndLossMax OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the maxmium value of near-end loss."
|
|
::= { fs6374LMStatsTableEntry 16 }
|
|
|
|
fs6374LMStatsNearEndLossAvg OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the average of the near-end loss measured
|
|
for a transaction."
|
|
::= { fs6374LMStatsTableEntry 17 }
|
|
|
|
fs6374LMStatsTxPktCount OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of frames with loss information
|
|
sent for a transaction."
|
|
::= { fs6374LMStatsTableEntry 18 }
|
|
|
|
fs6374LMStatsRxPktCount OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of frames with loss information
|
|
received for a transaction."
|
|
::= { fs6374LMStatsTableEntry 19 }
|
|
|
|
fs6374LMStatsThroughputpercent OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the throughput loss value for a transaction."
|
|
::= { fs6374LMStatsTableEntry 20 }
|
|
|
|
fs6374LMStatsResponseErrors OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of responses dropped due to
|
|
errors."
|
|
DEFVAL {0}
|
|
::= { fs6374LMStatsTableEntry 21 }
|
|
|
|
fs6374LMStatsResponseTimeout OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of queries Timedout."
|
|
DEFVAL {0}
|
|
::= { fs6374LMStatsTableEntry 22 }
|
|
|
|
fs6374LMStatsMeasurementOnGoing OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies whether for the particular session,
|
|
measurement is ongoing or not.
|
|
Complete(0) Indicates measurement is ongoing.
|
|
OnGoing(1) Indicates measurement has been completed.
|
|
Aborted(2) Indicates if the measurement is Stop by user or
|
|
if the measurement is aborted due to MPLS path Down"
|
|
DEFVAL {0}
|
|
::= { fs6374LMStatsTableEntry 23 }
|
|
|
|
fs6374LMDyadicMeasurement OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Loss Calculation done over
|
|
dyadic Measurement
|
|
enable(1) Indicates that Loss over Dyadic
|
|
disable(2) Indicates normal loss measurement."
|
|
DEFVAL {2}
|
|
::= { fs6374LMStatsTableEntry 24 }
|
|
|
|
fs6374LMRemoteSessionId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies Remote Session ID for the Loss/Comb LMDM
|
|
calculation done over dyadic Measurement."
|
|
::= { fs6374LMStatsTableEntry 25 }
|
|
|
|
fs6374LMDyadicProactiveRole OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Loss Calculation done
|
|
for which Dyadic proactive role."
|
|
::= { fs6374LMStatsTableEntry 26 }
|
|
|
|
fs6374IsLMBufferSQIEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies whether the SQI was enabled or disabled
|
|
for the corresponding session when the LM buffer was created.
|
|
A value of 'true' indicates that SQI was enabled for that service
|
|
during that particular session. A value of 'false' indicates that
|
|
SQI was disabled for that service during that particular session."
|
|
DEFVAL { false }
|
|
::= { fs6374LMStatsTableEntry 27 }
|
|
--------------------------------------------------------------------------------------
|
|
--End of Buffers for storing the summary of LM calculations
|
|
--------------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------------
|
|
--Start of Buffers for storing the summary of DM calculations
|
|
--------------------------------------------------------------------------------------
|
|
fs6374DMStatsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Fs6374DMStatsTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the table which holds the summary of delay
|
|
information based on Service name and Session Id."
|
|
::= { fs6374DMStats 1 }
|
|
|
|
fs6374DMStatsTableEntry OBJECT-TYPE
|
|
SYNTAX Fs6374DMStatsTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the delay Statistics table entry."
|
|
INDEX { fs6374ContextId,
|
|
fs6374ServiceName,
|
|
fs6374DMSessionId
|
|
}
|
|
::= { fs6374DMStatsTable 1 }
|
|
|
|
Fs6374DMStatsTableEntry ::= SEQUENCE {
|
|
fs6374DMStatsMplsType INTEGER,
|
|
fs6374DMStatsFwdTnlIdOrPwId Unsigned32,
|
|
fs6374DMStatsRevTnlId Unsigned32,
|
|
fs6374DMStatsSrcIpAddr OCTET STRING,
|
|
fs6374DMStatsDestIpAddr OCTET STRING,
|
|
fs6374DMStatsTrafficClass INTEGER,
|
|
fs6374DMStatsMode INTEGER,
|
|
fs6374DMStatsType INTEGER,
|
|
fs6374DMStatsTimeStampFormat FS6374TimeStampFormat,
|
|
fs6374DMStatsStartTime Unsigned32,
|
|
fs6374DMStatsMinDelay FS6374TimeRepresentation,
|
|
fs6374DMStatsMaxDelay FS6374TimeRepresentation,
|
|
fs6374DMStatsAvgDelay FS6374TimeRepresentation,
|
|
fs6374DMStatsMinRTDelay FS6374TimeRepresentation,
|
|
fs6374DMStatsMaxRTDelay FS6374TimeRepresentation,
|
|
fs6374DMStatsAvgRTDelay FS6374TimeRepresentation,
|
|
fs6374DMStatsMinIPDV FS6374TimeRepresentation,
|
|
fs6374DMStatsMaxIPDV FS6374TimeRepresentation,
|
|
fs6374DMStatsAvgIPDV FS6374TimeRepresentation,
|
|
fs6374DMStatsMinPDV FS6374TimeRepresentation,
|
|
fs6374DMStatsMaxPDV FS6374TimeRepresentation,
|
|
fs6374DMStatsAvgPDV FS6374TimeRepresentation,
|
|
fs6374DMStatsTxPktCount Unsigned32,
|
|
fs6374DMStatsRxPktCount Unsigned32,
|
|
fs6374DMStatsResponseErrors Unsigned32,
|
|
fs6374DMStatsResponseTimeout Unsigned32,
|
|
fs6374DMStatsMeasurementOnGoing INTEGER,
|
|
fs6374DMDyadicMeasurement INTEGER,
|
|
fs6374DMRemoteSessionId Unsigned32,
|
|
fs6374DMDyadicProactiveRole INTEGER,
|
|
fs6374DMStatsPaddingSize Unsigned32,
|
|
fs6374IsDMBufferSQIEnabled TruthValue
|
|
}
|
|
|
|
fs6374DMStatsMplsType OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the MPLS type which could be Tunnel/LSP
|
|
or PW."
|
|
::= { fs6374DMStatsTableEntry 1 }
|
|
|
|
fs6374DMStatsFwdTnlIdOrPwId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the tunnel Id for unidirectional in forward
|
|
direction or PW Id based on Mpls type."
|
|
::= { fs6374DMStatsTableEntry 2 }
|
|
|
|
fs6374DMStatsRevTnlId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the tunnel Id for unidirectional in reverse
|
|
direction."
|
|
::= { fs6374DMStatsTableEntry 3 }
|
|
|
|
fs6374DMStatsSrcIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE (0..40))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the source IP Address."
|
|
::= { fs6374DMStatsTableEntry 4 }
|
|
|
|
fs6374DMStatsDestIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE (0..40))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the destination IP Address."
|
|
::= { fs6374DMStatsTableEntry 5 }
|
|
|
|
fs6374DMStatsTrafficClass OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the traffic class."
|
|
::= { fs6374DMStatsTableEntry 6 }
|
|
|
|
fs6374DMStatsMode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the method (ondemand or proactive) used for DM.
|
|
This is not applicable for one-way type."
|
|
::= { fs6374DMStatsTableEntry 7 }
|
|
|
|
fs6374DMStatsType OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies type (oneWay or twoWay) used for DM."
|
|
::= { fs6374DMStatsTableEntry 8 }
|
|
|
|
fs6374DMStatsTimeStampFormat OBJECT-TYPE
|
|
SYNTAX FS6374TimeStampFormat
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the value of timestamp format for the DM."
|
|
::= { fs6374DMStatsTableEntry 9 }
|
|
|
|
fs6374DMStatsStartTime OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the time at which delay measurement starts."
|
|
::= { fs6374DMStatsTableEntry 10 }
|
|
|
|
fs6374DMStatsMinDelay OBJECT-TYPE
|
|
SYNTAX FS6374TimeRepresentation
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the minimum value of delay."
|
|
::= { fs6374DMStatsTableEntry 11 }
|
|
|
|
fs6374DMStatsMaxDelay OBJECT-TYPE
|
|
SYNTAX FS6374TimeRepresentation
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the maximum value of frame-delay."
|
|
::= { fs6374DMStatsTableEntry 12 }
|
|
|
|
fs6374DMStatsAvgDelay OBJECT-TYPE
|
|
SYNTAX FS6374TimeRepresentation
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the average delay measured for a one-way or
|
|
two-way delay measurement for a transaction."
|
|
::= { fs6374DMStatsTableEntry 13 }
|
|
|
|
fs6374DMStatsMinRTDelay OBJECT-TYPE
|
|
SYNTAX FS6374TimeRepresentation
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the minimum value of round trip delay."
|
|
::= { fs6374DMStatsTableEntry 14 }
|
|
|
|
fs6374DMStatsMaxRTDelay OBJECT-TYPE
|
|
SYNTAX FS6374TimeRepresentation
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the maximum value of round trip delay."
|
|
::= { fs6374DMStatsTableEntry 15 }
|
|
|
|
fs6374DMStatsAvgRTDelay OBJECT-TYPE
|
|
SYNTAX FS6374TimeRepresentation
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the average delay measured for a round trip
|
|
delay measurement for a transaction."
|
|
::= { fs6374DMStatsTableEntry 16 }
|
|
|
|
fs6374DMStatsMinIPDV OBJECT-TYPE
|
|
SYNTAX FS6374TimeRepresentation
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the minimum value of IPDV."
|
|
::= { fs6374DMStatsTableEntry 17 }
|
|
|
|
fs6374DMStatsMaxIPDV OBJECT-TYPE
|
|
SYNTAX FS6374TimeRepresentation
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the maximum value of IPDV."
|
|
::= { fs6374DMStatsTableEntry 18 }
|
|
|
|
fs6374DMStatsAvgIPDV OBJECT-TYPE
|
|
SYNTAX FS6374TimeRepresentation
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the average delay measured for a IPDV."
|
|
::= { fs6374DMStatsTableEntry 19 }
|
|
|
|
fs6374DMStatsMinPDV OBJECT-TYPE
|
|
SYNTAX FS6374TimeRepresentation
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the minimum value of PDV."
|
|
::= { fs6374DMStatsTableEntry 20 }
|
|
|
|
fs6374DMStatsMaxPDV OBJECT-TYPE
|
|
SYNTAX FS6374TimeRepresentation
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the maximum value of PDV."
|
|
::= { fs6374DMStatsTableEntry 21 }
|
|
|
|
fs6374DMStatsAvgPDV OBJECT-TYPE
|
|
SYNTAX FS6374TimeRepresentation
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the average delay measured for a PDV."
|
|
::= { fs6374DMStatsTableEntry 22 }
|
|
|
|
fs6374DMStatsTxPktCount OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the count of transmitted DM packets."
|
|
::= { fs6374DMStatsTableEntry 23 }
|
|
|
|
fs6374DMStatsRxPktCount OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the count of received DM packets."
|
|
::= { fs6374DMStatsTableEntry 24 }
|
|
|
|
fs6374DMStatsResponseErrors OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of Responses dropped due to errors."
|
|
DEFVAL {0}
|
|
::= { fs6374DMStatsTableEntry 25 }
|
|
|
|
fs6374DMStatsResponseTimeout OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of queries timedout."
|
|
DEFVAL {0}
|
|
::= { fs6374DMStatsTableEntry 26 }
|
|
|
|
fs6374DMStatsMeasurementOnGoing OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies whether for the particular session,
|
|
measurement is ongoing or not.
|
|
Complete(0) Indicates measurement is ongoing.
|
|
OnGoing(1) Indicates measurement has been completed.
|
|
Aborted(2) Indicates if the measurement is Stop by user or
|
|
if the measurement is aborted due to MPLS path Down"
|
|
DEFVAL {0}
|
|
::= { fs6374DMStatsTableEntry 27 }
|
|
|
|
fs6374DMDyadicMeasurement OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Delay Calculation done over
|
|
dyadic Measurement
|
|
enable(1) Indicates that Delay over Dyadic
|
|
disable(2) Indicates normal Delay measurement."
|
|
DEFVAL {2}
|
|
::= { fs6374DMStatsTableEntry 28 }
|
|
|
|
fs6374DMRemoteSessionId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies Remote Session ID for the Delay/Comb LMDM
|
|
calculation done over dyadic Measurement."
|
|
::= { fs6374DMStatsTableEntry 29 }
|
|
|
|
fs6374DMDyadicProactiveRole OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Delay Calculation done
|
|
for which Dyadic proactive role."
|
|
::= { fs6374DMStatsTableEntry 30 }
|
|
fs6374DMStatsPaddingSize OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Delay Calculation done
|
|
for which Padding size."
|
|
::= { fs6374DMStatsTableEntry 31 }
|
|
|
|
fs6374IsDMBufferSQIEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies whether the SQI was enabled or disabled
|
|
for the corresponding session when the DM buffer was created.
|
|
A value of 'true' indicates that SQI was enabled for that service
|
|
during that particular session. A value of 'false' indicates that
|
|
SQI was disabled for that service during that particular session."
|
|
DEFVAL { false }
|
|
::= { fs6374DMStatsTableEntry 32 }
|
|
|
|
--------------------------------------------------------------------------------------
|
|
--End of Buffers for storing the summary of DM calculations
|
|
--------------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------------
|
|
--Start of 6374 per context statistics table
|
|
--------------------------------------------------------------------------------------
|
|
fs6374StatsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Fs6374StatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the list of per virtual context 6374 Module Statistics."
|
|
::= { fs6374Stats 1 }
|
|
|
|
fs6374StatsTableEntry OBJECT-TYPE
|
|
SYNTAX Fs6374StatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Per virtual context 6374 Module Statistics."
|
|
|
|
INDEX { fs6374ContextId,
|
|
fs6374ServiceName }
|
|
|
|
::= { fs6374StatsTable 1 }
|
|
|
|
Fs6374StatsEntry ::= SEQUENCE {
|
|
fs6374StatsLmmOut Unsigned32,
|
|
fs6374StatsLmmIn Unsigned32,
|
|
fs6374StatsLmrOut Unsigned32,
|
|
fs6374StatsLmrIn Unsigned32,
|
|
fs6374Stats1LmOut Unsigned32,
|
|
fs6374Stats1LmIn Unsigned32,
|
|
fs6374Stats1DmOut Unsigned32,
|
|
fs6374Stats1DmIn Unsigned32,
|
|
fs6374StatsDmmOut Unsigned32,
|
|
fs6374StatsDmmIn Unsigned32,
|
|
fs6374StatsDmrOut Unsigned32,
|
|
fs6374StatsDmrIn Unsigned32,
|
|
fs6374StatsCmb1LmDmOut Unsigned32,
|
|
fs6374StatsCmb1LmDmIn Unsigned32,
|
|
fs6374StatsCmbLmmDmmOut Unsigned32,
|
|
fs6374StatsCmbLmmDmmIn Unsigned32,
|
|
fs6374StatsCmbLmrDmrOut Unsigned32,
|
|
fs6374StatsCmbLmrDmrIn Unsigned32
|
|
|
|
}
|
|
|
|
fs6374StatsLmmOut OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of LMM PDUs transmitted."
|
|
::= { fs6374StatsTableEntry 1 }
|
|
|
|
fs6374StatsLmmIn OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of LMM PDUs received."
|
|
::= { fs6374StatsTableEntry 2 }
|
|
|
|
fs6374StatsLmrOut OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of LMR PDUs transmitted."
|
|
::= { fs6374StatsTableEntry 3 }
|
|
|
|
fs6374StatsLmrIn OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of LMR PDUs received."
|
|
::= { fs6374StatsTableEntry 4 }
|
|
|
|
fs6374Stats1LmOut OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of 1LM PDUs transmitted."
|
|
::= { fs6374StatsTableEntry 5 }
|
|
|
|
fs6374Stats1LmIn OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of 1LM PDUs received."
|
|
::= { fs6374StatsTableEntry 6 }
|
|
|
|
fs6374Stats1DmOut OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of 1DM PDUs transmitted."
|
|
::= { fs6374StatsTableEntry 7 }
|
|
|
|
fs6374Stats1DmIn OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of 1DM PDUs received."
|
|
::= { fs6374StatsTableEntry 8 }
|
|
|
|
fs6374StatsDmmOut OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of DMM PDUs transmitted."
|
|
::= { fs6374StatsTableEntry 9 }
|
|
|
|
fs6374StatsDmmIn OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of DMM PDUs received."
|
|
::= { fs6374StatsTableEntry 10 }
|
|
|
|
fs6374StatsDmrOut OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of DMR PDUs transmitted."
|
|
::= { fs6374StatsTableEntry 11 }
|
|
|
|
fs6374StatsDmrIn OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of DMR PDUs received."
|
|
::= { fs6374StatsTableEntry 12 }
|
|
|
|
fs6374StatsCmb1LmDmOut OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of combined LMDM one way PDUs
|
|
transmitted."
|
|
::= { fs6374StatsTableEntry 13 }
|
|
|
|
fs6374StatsCmb1LmDmIn OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of combined LMDM one way PDUs
|
|
received."
|
|
::= { fs6374StatsTableEntry 14 }
|
|
|
|
fs6374StatsCmbLmmDmmOut OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of combined LMDM two way PDUs
|
|
transmitted."
|
|
::= { fs6374StatsTableEntry 15 }
|
|
|
|
fs6374StatsCmbLmmDmmIn OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of combined LMDM two way PDUs
|
|
received."
|
|
::= { fs6374StatsTableEntry 16 }
|
|
|
|
fs6374StatsCmbLmrDmrOut OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of combined LMR DMR two way PDUs
|
|
transmitted."
|
|
::= { fs6374StatsTableEntry 17 }
|
|
|
|
fs6374StatsCmbLmrDmrIn OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the number of combined LMR DMR two ways PDUs
|
|
received."
|
|
::= { fs6374StatsTableEntry 18 }
|
|
|
|
|
|
--------------------------------------------------------------------------------------
|
|
--End of 6374 per context statistics table
|
|
--------------------------------------------------------------------------------------
|
|
|
|
--------------------------------------------------------------------------------------
|
|
--Start of System level config table
|
|
--------------------------------------------------------------------------------------
|
|
fs6374SystemConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Fs6374SystemConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the table that contains system level
|
|
information."
|
|
::= { fs6374SystemConfig 1 }
|
|
|
|
fs6374SystemConfigEntry OBJECT-TYPE
|
|
SYNTAX Fs6374SystemConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the SystemConfig entry."
|
|
INDEX { fs6374ContextId
|
|
}
|
|
::= { fs6374SystemConfigTable 1 }
|
|
|
|
Fs6374SystemConfigEntry ::= SEQUENCE {
|
|
fs6374SystemControl INTEGER,
|
|
fs6374ModuleStatus INTEGER,
|
|
fs6374DMBufferClear TruthValue,
|
|
fs6374LMBufferClear TruthValue,
|
|
fs6374DebugLevel Unsigned32,
|
|
fs6374TSFormatSupported FS6374SuppTimeStampFormat
|
|
}
|
|
|
|
fs6374SystemControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
start (1),
|
|
shutdown (2)
|
|
}
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the administrative system control status of
|
|
6374 module.
|
|
The value 'start' (1) indicates that all
|
|
resources required by the module should be allocated
|
|
and 6374 should be supported in the device on all ports.
|
|
The value 'shutdown' (2) indicates that 6374 should be
|
|
shutdown in the device on all ports and all allocated
|
|
memory must be released."
|
|
DEFVAL { start }
|
|
::= { fs6374SystemConfigEntry 1 }
|
|
|
|
fs6374ModuleStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the administrative module status of 6374 module.
|
|
This enables or disables 6374 in the system.
|
|
A value of 'enabled' (1) indicates that 6374 is
|
|
enabled in the device. A value of 'disabled'
|
|
(2) indicates that 6374 is disabled in the device."
|
|
DEFVAL { enabled }
|
|
::= { fs6374SystemConfigEntry 2 }
|
|
|
|
fs6374DMBufferClear OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the trigger to remove the contents of Buffer
|
|
maintained for storing delay measured at various times.
|
|
Note: Get operation value should be ignored."
|
|
::= { fs6374SystemConfigEntry 3 }
|
|
|
|
fs6374LMBufferClear OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the trigger to remove the contents of Buffer
|
|
maintained for storing loss measured at various times.
|
|
|
|
Note: Get operation value should be ignored."
|
|
::= { fs6374SystemConfigEntry 4 }
|
|
|
|
fs6374DebugLevel OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..4294967295)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to enable the tracing in the selected submodule.
|
|
A 32 bit integer is used to store the Tracing level in the specified
|
|
module.
|
|
Different Tracing Levels -
|
|
BIT 0 - Initialisation and Shutdown Trace.
|
|
BIT 1 - Management trace.
|
|
BIT 2 - Critical trace.
|
|
BIT 3 - Control plane.
|
|
BIT 4 - Packet Dump.
|
|
BIT 5 - OS Resource trace.
|
|
BIT 6 - All Failure trace (All failures including Packet Validation).
|
|
BIT 7 - Function Entry.
|
|
BIT 8 - Function Exit.
|
|
Note : BIT0 is the least significant bit and BIT31 is the most
|
|
significant bit.
|
|
|
|
By default, critical trace(bit 3) is set."
|
|
|
|
DEFVAL { '00000003'H }
|
|
::= { fs6374SystemConfigEntry 5 }
|
|
|
|
fs6374TSFormatSupported OBJECT-TYPE
|
|
SYNTAX FS6374SuppTimeStampFormat
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the timestamp format supported in the system.
|
|
The below specified timestamp formats are supported in the system.
|
|
timeStampFormatNTP (2),
|
|
timeStampFormatIEEE1588 (3)
|
|
When the object 'fs6374TSFNegotiation' is enabled in the service,
|
|
the supported timestamp formats will be used for negotiation process."
|
|
::= { fs6374SystemConfigEntry 6 }
|
|
--------------------------------------------------------------------------------------
|
|
--End of System level config table
|
|
--------------------------------------------------------------------------------------
|
|
|
|
--------------------------------------------------------------------------------------
|
|
--Start of Traps
|
|
--------------------------------------------------------------------------------------
|
|
fs6374NotificationsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Fs6374NotificationsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the list of Traps supported in 6374."
|
|
::= { fs6374Notifications 1 }
|
|
|
|
fs6374NotificationsEntry OBJECT-TYPE
|
|
SYNTAX Fs6374NotificationsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the notification entry."
|
|
INDEX { fs6374ContextId }
|
|
::= { fs6374NotificationsTable 1 }
|
|
|
|
Fs6374NotificationsEntry ::= SEQUENCE {
|
|
fs6374LMDMTrapControl FS6374Traps
|
|
}
|
|
|
|
|
|
fs6374LMDMTrapControl OBJECT-TYPE
|
|
SYNTAX FS6374Traps
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies a vector of Boolean notification types,
|
|
used to enable or disable the LM&DM Traps:
|
|
bTrapUnsupportedVersion (1),
|
|
bTrapUnsupportedControlCode (2),
|
|
bTrapUnsupportedDataFormat (3),
|
|
bTrapConnectionMismatch (4),
|
|
bTrapUnsupportedMandatoryTLVObject (5),
|
|
bTrapUnsupportedTimeStamp (6),
|
|
bTrapResponseTimeout (7),
|
|
bTrapResourceUnavailable (8),
|
|
bTrapTestAbort (9),
|
|
bTrapProactiveTestRestart(10),
|
|
bTrapUnsupportedQueryInterval(11)
|
|
"
|
|
::= { fs6374NotificationsEntry 1 }
|
|
|
|
END
|