Observium_CE/mibs/aricent/ARICENT-fs6374-MIB

2124 lines
78 KiB
Plaintext

-- Copyright (C) 2008-2016 Aricent. All Rights Reserved
-- $Id: fs6374.mib,v 1.3 2017/01/12 12:55:38 siva Exp $
-- fs6374 Proprietary MIB Definition
ARICENT-fs6374-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
enterprises,Unsigned32,Integer32 FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
TruthValue,RowStatus FROM SNMPv2-TC;
fs6374MIB MODULE-IDENTITY
LAST-UPDATED "201209050000Z"
ORGANIZATION "ARICENT COMMUNICATIONS SOFTWARE"
CONTACT-INFO "support@aricent.com"
DESCRIPTION
"The Proprietary MIB for Loss and Delay measurement based on IETF RFC6374"
REVISION "201209050000Z"
DESCRIPTION
"The Proprietary MIB for Loss and Delay measurement based on IETF RFC6374"
::= { enterprises aricent-communication-holding-ltd(29601) iss(2) 107 }
-- ******************************************************************
-- Textual conventions
-- ******************************************************************
FS6374Traps ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates the Traps :
none(0) Dummy Bit
bTrapUnsupportedVersion(1) Protocol version not supported
bTrapUnsupportedControlCode(2) Control Code not supported
bTrapUnsupportedDataFormat(3) Data format specified in query
not supported
bTrapConnectionMismatch(4) Session Identifier in response
does not match the one sent in
the Query Message
bTrapUnsupportedMandatoryTLVObject(5) TLV received other than the
supported
bTrapUnsupportedTimeStamp(6) Timestamp format not supported
bTrapResponseTimeout(7) Response Timeout
bTrapResourceUnavailable(8) MPLS down, BFD session not
working or mismatch in traffic
class wrt BFD
bTrapTestAbort(9) On-demand/ Pro-active test aborted
explicitly by administrator or by
LSP/PW down
bTrapProactiveTestRestart(10) Pro-active test restarted for loss/
delay/combined Loss-Delay when LSP/PW
comes up
bTrapUnsupportedQueryInterval(11) Querier has received response with
Unsupported Query Interval"
SYNTAX BITS{
none (0),
bTrapUnsupportedVersion (1),
bTrapUnsupportedControlCode (2),
bTrapUnsupportedDataFormat (3),
bTrapConnectionMismatch (4),
bTrapUnsupportedMandatoryTLVObject (5),
bTrapUnsupportedTimeStamp (6),
bTrapResponseTimeout (7),
bTrapResourceUnavailable (8),
bTrapTestAbort(9),
bTrapProactiveTestRestart(10),
bTrapUnsupportedQueryInterval(11)
}
FS6374TimeStampFormat ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An enumerated value indicates the timestamp format used for loss and
delay.
TimeStampFormatNull(0) Indicates that timestamp field does not
contain a meaningful timestamp.
TimeStampFormatSequence(1) Indicates that the timestamp field is to
be viewed as a simple 64-bit sequence
number.
TimeStampFormatNTP(2) This format consists of a 32-bit seconds
field followed by a 32-bit
fractional seconds field, so that it can be
regarded as a fixed-point 64-bit quantity.
TimeStampFormatIEEE1588(3) This truncated format consists of a 32-bit
seconds field followed by a 32-bit
nanoseconds field, and is the same as
IEEE 1588v1 timestamp format."
SYNTAX INTEGER{
timeStampFormatNull (0),
timeStampFormatSequence (1),
timeStampFormatNTP (2),
timeStampFormatIEEE1588 (3)
}
Fs6374TransmitStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An enumerated value indicates whether particular transmission can be
initiated.
start(1) To initiate the transmission.
stop(2) To stop the transmission.
ready(3) Indicates transmission can be initiated.
notReady(4) Indicates transmission can not be initiated."
SYNTAX INTEGER {
start (1),
stop (2),
ready (3),
notReady (4)
}
FS6374TimeRepresentation ::= TEXTUAL-CONVENTION
DISPLAY-HINT "4d:4d"
STATUS current
DESCRIPTION
"A specification used to represent time stamp.
field octets contents range
----- ------ -------- -----
1 1-4 seconds 0..4294967295
2 5-8 nanoseconds/picoseconds 0..0..4294967295 "
SYNTAX OCTET STRING (SIZE (8))
FS6374SuppTimeStampFormat ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This object specifies the Timestamp formats supported by the system.
tsFormatNTP(1) This format consists of a 32-bit seconds
field followed by a 32-bit fractional seconds
(picoseconds) field, so that it can be regarded
as a fixed-point 64-bit quantity.
tsFormatIEEE1588(2) This truncated format consists of a 32-bit
seconds field followed by a 32-bit
nanoseconds field, and is the same as
IEEE 1588v1 timestamp format."
SYNTAX INTEGER{
tsFormatNTP (1),
tsFormatIEEE1588 (2)
}
---------------------------------------------------
-- Top level components of this MIB module.
---------------------------------------------------
-- Service Config Table --
fs6374ServiceConfig OBJECT IDENTIFIER ::= { fs6374MIB 1 }
-- Configuration Table for LM/DM --
fs6374ParamsConfig OBJECT IDENTIFIER ::= { fs6374MIB 2 }
-- Buffers for storing the LM and DM calculations --
fs6374LMBuffer OBJECT IDENTIFIER ::= { fs6374MIB 3 }
fs6374DMBuffer OBJECT IDENTIFIER ::= { fs6374MIB 4 }
-- Statistics for storing the summary of LM and DM calculations --
fs6374LMStats OBJECT IDENTIFIER ::= { fs6374MIB 5 }
fs6374DMStats OBJECT IDENTIFIER ::= { fs6374MIB 6 }
-- Statistics Table for 6374 --
fs6374Stats OBJECT IDENTIFIER ::= { fs6374MIB 7 }
-- System Level Config Table --
fs6374SystemConfig OBJECT IDENTIFIER ::= { fs6374MIB 8 }
-- Traps --
fs6374Notifications OBJECT IDENTIFIER ::= { fs6374MIB 9 }
--------------------------------------------------------------------------------------
--Start of Service Config Table
--------------------------------------------------------------------------------------
fs6374ServiceConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Fs6374ServiceConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies a table that holds the service configurations."
::= { fs6374ServiceConfig 1 }
fs6374ServiceConfigEntry OBJECT-TYPE
SYNTAX Fs6374ServiceConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies Service Config Entry."
INDEX { fs6374ContextId,
fs6374ServiceName }
::= { fs6374ServiceConfigTable 1 }
Fs6374ServiceConfigEntry ::= SEQUENCE {
fs6374ContextId Unsigned32,
fs6374ServiceName OCTET STRING,
fs6374MplsPathType INTEGER,
fs6374FwdTnlIdOrPwId Unsigned32,
fs6374RevTnlId Unsigned32,
fs6374SrcIpAddr OCTET STRING,
fs6374DestIpAddr OCTET STRING,
fs6374EncapType INTEGER,
fs6374TrafficClass INTEGER,
fs6374RowStatus RowStatus,
fs6374DyadicMeasurement INTEGER,
fs6374TSFNegotiation INTEGER,
fs6374TSNegotiatedFormat Unsigned32,
fs6374DyadicProactiveRole INTEGER,
fs6374QueryTransmitRetryCount Unsigned32,
fs6374SessionIntervalQueryStatus INTEGER,
fs6374MinReceptionIntervalInMilliseconds Unsigned32
}
fs6374ContextId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the unique identifier to identifies the
virtual router context.Currently, the implementation supports
only a single virtual instance of the router."
::= { fs6374ServiceConfigEntry 1 }
fs6374ServiceName OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..40))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the unique name of the LSP/PW Service."
::= { fs6374ServiceConfigEntry 2 }
fs6374MplsPathType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the Mpls type which could be Tunnel/LSP or PW."
::= { fs6374ServiceConfigEntry 3 }
fs6374FwdTnlIdOrPwId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the ID which could be Tunnel Id for
unidirectional in forward direction or PW Id based on Mpls type."
::= { fs6374ServiceConfigEntry 4 }
fs6374RevTnlId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the ID which is the Tunnel Id for
unidirectional in reverse direction."
::= { fs6374ServiceConfigEntry 5 }
fs6374SrcIpAddr OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..40))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the originating IP Address of the
unidirectional Tunnel or PW."
::= { fs6374ServiceConfigEntry 6 }
fs6374DestIpAddr OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..40))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the terminating IP Address of the
unidirectional Tunnel or PW."
::= { fs6374ServiceConfigEntry 7 }
fs6374EncapType OBJECT-TYPE
SYNTAX INTEGER{
withGALHEADER (1),
withoutGALHEADER (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the header type."
DEFVAL { withGALHEADER }
::= { fs6374ServiceConfigEntry 8 }
fs6374TrafficClass OBJECT-TYPE
SYNTAX Integer32(0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the traffic class."
DEFVAL {0}
::= { fs6374ServiceConfigEntry 9 }
fs6374RowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the status of service configuration row.
The writable columns in a row can be changed even if the row
is active but writable columns cannot be changed if either of
loss/delay/combined loss-delay test is in-progress.
Applicable values are CREATE_AND_GO, ACTIVE and DESTROY."
::= { fs6374ServiceConfigEntry 10 }
fs6374DyadicMeasurement OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the Dyadic Measurement status as
enabled or disabled."
DEFVAL { disable }
::= { fs6374ServiceConfigEntry 11 }
fs6374TSFNegotiation OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the Timestamp Format Negotiation status as
enabled or disabled.
This configuration is applicable only for Non-dyadic Two-way DM
and Combined LMDM and value should be configured at querier end.
When it is enabled, if the QTF and RTF are different, the
responder will fill Preferred Timestamp format based on the
supported timestamp 'fs6374TSFormatSupported' and Timestamp format
configured for DM/combined LMDM, the querier will change the
format if responder's format is supported by querier."
DEFVAL { disabled }
::= { fs6374ServiceConfigEntry 12 }
fs6374TSNegotiatedFormat OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the Negotiated Time Stamp Format of the
querier. This negotiated format is applicable only for
Non-dyadic Two-way DM and Combined LMDM.
The negotiated timestamp format can be either
timeStampFormatNTP (2) or
timeStampFormatIEEE1588 (3).
The negotiated Timestamp format will be used as the timestamp for
delay measurement process in both querier and responder.
This object displays the negotiated format only if
`fs6374TSFNegotiation` is enabled or else timeStampFormatIEEE1588
will be displayed as negotiated format."
::= { fs6374ServiceConfigEntry 13 }
fs6374DyadicProactiveRole OBJECT-TYPE
SYNTAX INTEGER {
active (1),
passive (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the Dyadic Measurement Proactive Role
status as active or passive.
If configured as passive, dyadic will initiated only after
initiated from active on peer end.
If configured as active, dyadic will be initiated."
DEFVAL { passive }
::= { fs6374ServiceConfigEntry 14 }
fs6374QueryTransmitRetryCount OBJECT-TYPE
SYNTAX Unsigned32(3..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the maximum number of retries of queries by a session
when querier is not getting response from the responder.
This object is used for congestion control at querier for outgoing packets."
DEFVAL { 25 }
::= { fs6374ServiceConfigEntry 15 }
fs6374SessionIntervalQueryStatus OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the Session Interval Query status as
enabled or disabled. This is applicable only for sending SQI TLV.
Whereas for responding to SQI TLV this is not mandatory to be enabled."
DEFVAL { enable }
::= { fs6374ServiceConfigEntry 16 }
fs6374MinReceptionIntervalInMilliseconds OBJECT-TYPE
SYNTAX Unsigned32(100..10000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the minimum time interval between two query
packets at which the service is ready to receive the packets.
This object is used for congestion control and rate limit the incoming
queries at responder. This will be different from Transmit query interval
time of a service. By default both transmit query interval and
receive query interval are same. This has a granularity of 10 milliseconds."
DEFVAL { 100 }
::= { fs6374ServiceConfigEntry 17 }
--------------------------------------------------------------------------------------
--End of Service Config Table
--------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------
--Start of Configuration Table for LM/DM
--------------------------------------------------------------------------------------
fs6374ParamsConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Fs6374ParamsConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies all the configurations related to LM and DM
as per virtual context of the router."
::= { fs6374ParamsConfig 1 }
fs6374ParamsConfigTableEntry OBJECT-TYPE
SYNTAX Fs6374ParamsConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies per virtual context LM and DM configuration parameters.
An entry in this table is created when a virtual context
is created."
INDEX { fs6374ContextId,
fs6374ServiceName }
::= { fs6374ParamsConfigTable 1 }
Fs6374ParamsConfigTableEntry ::= SEQUENCE {
fs6374LMType INTEGER,
fs6374LMMethod INTEGER,
fs6374LMMode INTEGER,
fs6374LMNoOfMessages Unsigned32,
fs6374LMTimeIntervalInMilliseconds Unsigned32,
fs6374LMTimeStampFormat FS6374TimeStampFormat,
fs6374LMTransmitStatus Fs6374TransmitStatus,
fs6374DMType INTEGER,
fs6374DMMode INTEGER,
fs6374DMTimeIntervalInMilliseconds Unsigned32,
fs6374DMNoOfMessages Unsigned32,
fs6374DMTimeStampFormat FS6374TimeStampFormat,
fs6374DMTransmitStatus Fs6374TransmitStatus,
fs6374CmbLMDMType INTEGER,
fs6374CmbLMDMMethod INTEGER,
fs6374CmbLMDMMode INTEGER,
fs6374CmbLMDMNoOfMessages Unsigned32,
fs6374CmbLMDMTimeIntervalInMilliseconds Unsigned32,
fs6374CmbLMDMTimeStampFormat FS6374TimeStampFormat,
fs6374CmbLMDMTransmitStatus Fs6374TransmitStatus,
fs6374DMPaddingSize Unsigned32,
fs6374CmbLMDMPaddingSize Unsigned32
}
fs6374LMType OBJECT-TYPE
SYNTAX INTEGER{
oneway (1),
twoway (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the type of LM calculation.
oneway(1) Indicates that calculation of LM will be in one way.
twoway(2) Indicates that calculation of LM will be in two way.
This object cannot be modified when fs6374LMTransmitStatus
is `notReady`."
DEFVAL { twoway }
::= { fs6374ParamsConfigTableEntry 1 }
fs6374LMMethod OBJECT-TYPE
SYNTAX INTEGER{
direct (1),
inferred (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the mode in which LM feature will work.
direct(1) Indicates that the LM feature will work in
Direct Method.
inferred(2) Indicates that LM feature will work in
Inferred Method.
This object cannot be modified when fs6374LMTransmitStatus
is `notReady`."
DEFVAL { inferred }
::= { fs6374ParamsConfigTableEntry 2 }
fs6374LMMode OBJECT-TYPE
SYNTAX INTEGER{
onDemand (1),
proActive (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the method of LM calculation.
onDemand(1) Indicates that calculation of LM will be
done based on user request.
proActive(2) Indicates that calculation of LM will be
done proactively.
when this object is set as pro-active and based on the object
fs6374LMType and fs6374LMTransmitStatus test will be started
immediately."
DEFVAL { onDemand }
::= { fs6374ParamsConfigTableEntry 3 }
fs6374LMNoOfMessages OBJECT-TYPE
SYNTAX Unsigned32 (1..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the number of queries to be sent in a session
when method for LM calculation is Ondemand.
This object cannot be modified when fs6374LMTransmitStatus
is `notReady`."
DEFVAL { 10 }
::= { fs6374ParamsConfigTableEntry 4 }
fs6374LMTimeIntervalInMilliseconds OBJECT-TYPE
SYNTAX Unsigned32(100..10000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the time interval between two query packets
for LM with the granularity of 10milliseconds.
This object cannot be modified when fs6374LMTransmitStatus
is `notReady`."
DEFVAL { 1000 }
::= { fs6374ParamsConfigTableEntry 5 }
fs6374LMTimeStampFormat OBJECT-TYPE
SYNTAX FS6374TimeStampFormat
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the preferred timestamp format
which will be used for LM.
The below specified timestamp formats are supported for
Loss Measurement but now, time stamp format NTP is not support.
timeStampFormatNull (0),
timeStampFormatSequence (1),
timeStampFormatNTP (2),
timeStampFormatIEEE1588 (3).
This object cannot be modified if fs6374LMMTransmitStatus
is `notReady`."
DEFVAL { timeStampFormatIEEE1588 }
::= { fs6374ParamsConfigTableEntry 6 }
fs6374LMTransmitStatus OBJECT-TYPE
SYNTAX Fs6374TransmitStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the status of loss transmit."
DEFVAL { ready }
::= { fs6374ParamsConfigTableEntry 7 }
fs6374DMType OBJECT-TYPE
SYNTAX INTEGER{
oneway (1),
twoway (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the type of DM calculation.
oneway(1) Indicates that calculation of DM will be one-way.
twoway(2) Indicates that calculation of DM will be two-way.
This object cannot be modified when fs6374DMTransmitStatus
is `notReady`."
DEFVAL { twoway }
::= { fs6374ParamsConfigTableEntry 8 }
fs6374DMMode OBJECT-TYPE
SYNTAX INTEGER{
onDemand (1),
proActive (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the method of DM calculation.
onDemand(1) Indicates that calculation of DM will be done
based on user request.
proActive(2) Indicates that calculation of DM will be done
proactively.
when this object is set as proactive and based on the object
fs6374DMType and fs6374DMTransmitStatus test will be started
immediately."
DEFVAL { onDemand }
::= { fs6374ParamsConfigTableEntry 9 }
fs6374DMTimeIntervalInMilliseconds OBJECT-TYPE
SYNTAX Unsigned32(100..10000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the time interval between two query packets
for DM with the granularity of 10milliseconds.
This object cannot be modified when fs6374DMTransmitStatus
is `notReady`."
DEFVAL { 1000 }
::= { fs6374ParamsConfigTableEntry 10 }
fs6374DMNoOfMessages OBJECT-TYPE
SYNTAX Unsigned32 (1..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the number of queries to be sent in a session
when method for LM calculation is Ondemand.
This object cannot be modified when fs6374DMTransmitStatus
is `notReady`."
DEFVAL { 10 }
::= { fs6374ParamsConfigTableEntry 11 }
fs6374DMTimeStampFormat OBJECT-TYPE
SYNTAX FS6374TimeStampFormat
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the preferred timestamp format
which will be used for delay measurement calculation.
The below specified timestamp formats are supported for
Delay Measurement but now, time stamp format NTP is not support.
timeStampFormatNTP (2),
timeStampFormatIEEE1588 (3).
This object cannot be modified when fs6374DMTransmitStatus
is `notReady`."
DEFVAL { timeStampFormatIEEE1588 }
::= { fs6374ParamsConfigTableEntry 12 }
fs6374DMTransmitStatus OBJECT-TYPE
SYNTAX Fs6374TransmitStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the status of delay transmit and
an Enumerated value set to 'start' to initiate 1DM or
DMM transmission and 'stop' to stop 1DM or DMM transmission.
The values 'ready' and 'notReady' indicate whether
1DM or DMM can be initiated or not.
Note: User can not set to 'ready' or 'notReady'."
DEFVAL { ready }
::= { fs6374ParamsConfigTableEntry 13 }
fs6374CmbLMDMType OBJECT-TYPE
SYNTAX INTEGER { oneway(1), twoway(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the combined LMDM calculation type
provided by the service. The following two types are
possible:
oneway - Indicates that calculation of combined LMDM will be
in one way.
twoway - Indicates that calculation of combined LMDM will be
in two way.
The combined LMDM calculation type cannot be modified when the
fs6374CmbLMDMTransmitStatus is `notReady`."
DEFVAL { twoway }
::= { fs6374ParamsConfigTableEntry 14 }
fs6374CmbLMDMMethod OBJECT-TYPE
SYNTAX INTEGER { direct(1), inferred(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the combined LMDM calculation method
provided by the service. The following two methods are
possible:
direct - Indicates that the combined LMDM feature will work
in Direct Method.
inferred - Indicates that the combined LMDM feature will work
in Inferred Method.
The combined LMDM calculation method cannot be modified when the
fs6374CmbLMDMTransmitStatus is `notReady`."
DEFVAL { inferred }
::= { fs6374ParamsConfigTableEntry 15 }
fs6374CmbLMDMMode OBJECT-TYPE
SYNTAX INTEGER { onDemand(1), proActive(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the combined LMDM calculation mode
provided by the service. The following two modes are
possible:
onDemand - Indicates that calculation of combined LMDM will
be done based on user request.
proActive - Indicates that calculation of combined LMDM will
be done proactively.
when this object is set as pro-active mode and based on the object
fs6374CmbLMDMType and fs6374CmbLMDMTransmitStatus test will be
started immediately.
The combined LMDM calculation mode cannot be modified when the
fs6374CmbLMDMTransmitStatus is `notReady`."
DEFVAL { onDemand }
::= { fs6374ParamsConfigTableEntry 16 }
fs6374CmbLMDMNoOfMessages OBJECT-TYPE
SYNTAX Unsigned32 (1..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the number of combined LMDM queries to be
sent in a session when method for LM calculation is `Ondemand`.
This object cannot be modified when the fs6374CmbLMDMTransmitStatus
is `notReady`."
DEFVAL { 10 }
::= { fs6374ParamsConfigTableEntry 17 }
fs6374CmbLMDMTimeIntervalInMilliseconds OBJECT-TYPE
SYNTAX Unsigned32(100..10000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the time interval between two combined
LMDM query packets for LM with the granularity of 10 milliseconds.
This object cannot be modified when fs6374CmbLMDMTransmitStatus
is `notReady`."
DEFVAL { 1000 }
::= { fs6374ParamsConfigTableEntry 18 }
fs6374CmbLMDMTimeStampFormat OBJECT-TYPE
SYNTAX FS6374TimeStampFormat
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the preferred timestamp format
which will be used for combined LMDM calculation.
The below specified timestamp formats are supported for
Combined loss and delay Measurement but now, time stamp
format NTP is not support.
timeStampFormatNTP (2),
timeStampFormatIEEE1588 (3).
This object cannot be modified when fs6374CmbLMDMTransmitStatus
is `notReady`."
DEFVAL { timeStampFormatIEEE1588 }
::= { fs6374ParamsConfigTableEntry 19 }
fs6374CmbLMDMTransmitStatus OBJECT-TYPE
SYNTAX Fs6374TransmitStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies combined LMDM calculation transmission
status. The following two values are possible to set by
administrator:
start - To initiate combined LMDM transmission.
stop - To stop the combined LMDM transmission.
The values 'ready' and 'notReady' indicate whether combined LMDM
can be initiated or not.
The value `notReady` specifies that particular transmission is
already On-going for that service.
The Value `ready` specifies that particular transmission can be
initiated for the service.
Note: User can not set to 'ready' or 'notReady'."
DEFVAL { ready }
::= { fs6374ParamsConfigTableEntry 20 }
fs6374DMPaddingSize OBJECT-TYPE
SYNTAX Unsigned32(0..9000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the size of the pattern to be included in
the Padding TLV of DM message.
This configuration is applicable only for Non-dyadic DM
Measurement.
Maximum frame size suggested by RFC6374 for Padding TLV is
9000 bytes. Based on the interface MTU, the maximum frame size
of DM padding TLV size can be chosen.
The TLV value field in PaddingTLV will have maximum of 255 bytes.
When the fs6374DMPaddingSize is configured with more than
255 bytes then total size will be split across multiple TLVs.
Default value of padding pattern is updated as zero for the
size specified by this object. If the object is configured
with the value as `zero` then padding TLV will not be included.
There are two types of padding TLV are specified in RFC6374
section 3.5 but the padding TLV type 0 - Copy in response
is supported.
This object cannot be modified when fs6374DMTransmitStatus
is `notReady`."
DEFVAL { 0 }
::= { fs6374ParamsConfigTableEntry 21 }
fs6374CmbLMDMPaddingSize OBJECT-TYPE
SYNTAX Unsigned32(0..9000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the size of the pattern to be included in
the Padding TLV of Combined LMDM message.
This configuration is applicable only for Non-dyadic
Combined LMDM Measurement.
Maximum frame size suggested by RFC6374 for Padding TLV is
9000 bytes. Based on the interface MTU, the maximum frame size
of Combined LMDM padding TLV size can be chosen.
The TLV value field in PaddingTLV will have maximum of 255 bytes.
When the fs6374CmbLMDMPaddingSize is configured with more than
255 bytes then total size will be split across multiple TLVs.
Default value of padding pattern is updated as zero for the
size specified by this object. If the object is configured
with the value as `zero` then padding TLV will not be included.
There are two types of padding TLV are specified in RFC6374
section 3.5 but the padding TLV type 0 - Copy in
response is supported.
This object cannot be modified when fs6374CmbLMDMTransmitStatus
is `notReady`."
DEFVAL { 0 }
::= { fs6374ParamsConfigTableEntry 22 }
--------------------------------------------------------------------------------------
-- End of Configuration Table for LM/DM
--------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------
-- Start of Buffers for storing the LM calculations
--------------------------------------------------------------------------------------
fs6374LMTable OBJECT-TYPE
SYNTAX SEQUENCE OF Fs6374LMTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the table that holds the detailed buffer
information for Loss measurement measured at various time
intervals."
::= { fs6374LMBuffer 1 }
fs6374LMTableEntry OBJECT-TYPE
SYNTAX Fs6374LMTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the Loss statistics table entry."
INDEX { fs6374ContextId,
fs6374ServiceName,
fs6374LMSessionId,
fs6374LMSeqNum
}
::= { fs6374LMTable 1 }
Fs6374LMTableEntry ::= SEQUENCE {
fs6374LMSessionId Unsigned32,
fs6374LMSeqNum Unsigned32,
fs6374LMTxLossAtSenderEnd Unsigned32,
fs6374LMRxLossAtSenderEnd Unsigned32,
fs6374LMRxLossAtReceiverEnd Unsigned32,
fs6374LMMeasurementTimeTakenInMilliseconds FS6374TimeRepresentation,
fs6374LMTransmitResultOK TruthValue,
fs6374LMTestPktsCount Unsigned32
}
fs6374LMSessionId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the Loss measurement session id."
::= { fs6374LMTableEntry 1 }
fs6374LMSeqNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the locally maintained sequence number of
loss Entries."
::= { fs6374LMTableEntry 2 }
fs6374LMTxLossAtSenderEnd OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the transmit loss value which is calculated at
sender end.This value is populated for Two-way measurement."
::= { fs6374LMTableEntry 3 }
fs6374LMRxLossAtSenderEnd OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the receiver loss value which is calculated at
sender end. This value is populated for Two-way measurement."
::= { fs6374LMTableEntry 4 }
fs6374LMRxLossAtReceiverEnd OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the receiver loss value which is calculated at
sender end. This value is populated for one-way measurement."
::= { fs6374LMTableEntry 5 }
fs6374LMMeasurementTimeTakenInMilliseconds OBJECT-TYPE
SYNTAX FS6374TimeRepresentation
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the time taken to measure loss."
::= { fs6374LMTableEntry 6 }
fs6374LMTransmitResultOK OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the result of the operation:
- true The Loss measurement Message (1LM or LMM) will be
(or has been) sent.
- false The Loss measurement Message (1LM or LMM) will not be
sent."
DEFVAL { true }
::= { fs6374LMTableEntry 7 }
fs6374LMTestPktsCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the total number of test PDUs transmitted at sender end for each transaction. This value is populated for measurement.
"
::= { fs6374LMTableEntry 8 }
--------------------------------------------------------------------------------------
--End of Buffers for storing the LM calculations
--------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------
--Start of Buffers for storing the DM calculations
--------------------------------------------------------------------------------------
fs6374DMTable OBJECT-TYPE
SYNTAX SEQUENCE OF Fs6374DMTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the table that contains the detailed buffer
information for delay measured at various times."
::= { fs6374DMBuffer 1 }
fs6374DMTableEntry OBJECT-TYPE
SYNTAX Fs6374DMTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The object specifies the detailed delay buffer table entry."
INDEX { fs6374ContextId,
fs6374ServiceName,
fs6374DMSessionId,
fs6374DMSeqNum
}
::= { fs6374DMTable 1 }
Fs6374DMTableEntry ::= SEQUENCE {
fs6374DMSessionId Unsigned32,
fs6374DMSeqNum Unsigned32,
fs6374DMDelayValue FS6374TimeRepresentation,
fs6374DMRTDelayValue FS6374TimeRepresentation,
fs6374DMIPDV FS6374TimeRepresentation,
fs6374DMPDV FS6374TimeRepresentation,
fs6374DMTransmitResultOK TruthValue
}
fs6374DMSessionId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the delay measurement session id."
::= { fs6374DMTableEntry 1 }
fs6374DMSeqNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the locally maintained sequence number of
delay entries."
::= { fs6374DMTableEntry 2 }
fs6374DMDelayValue OBJECT-TYPE
SYNTAX FS6374TimeRepresentation
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the measured delay value."
::= { fs6374DMTableEntry 3 }
fs6374DMRTDelayValue OBJECT-TYPE
SYNTAX FS6374TimeRepresentation
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the measured round trip delay value."
::= { fs6374DMTableEntry 4 }
fs6374DMIPDV OBJECT-TYPE
SYNTAX FS6374TimeRepresentation
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the Inter frame delay variation (IFDV),
calculated with respect to current transaction."
::= { fs6374DMTableEntry 5 }
fs6374DMPDV OBJECT-TYPE
SYNTAX FS6374TimeRepresentation
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the Frame delay variation (IFDV), calculated
with respect to current transaction."
::= { fs6374DMTableEntry 6 }
fs6374DMTransmitResultOK OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the result of the operation:
- true The Delay measurement Message (1DM or DMM) will be
(or has been) sent.
- false The Delay measurement Message (1DM or DMM) will not
be sent."
DEFVAL { true }
::= { fs6374DMTableEntry 7 }
--------------------------------------------------------------------------------------
--End of Buffers for storing the DM calculations
--------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------
--Start of Buffers for storing the summary of LM calculations
--------------------------------------------------------------------------------------
fs6374LMStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF Fs6374LMStatsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the table that contains the summary of Loss
information based on Service name and Session Id."
::= { fs6374LMStats 1 }
fs6374LMStatsTableEntry OBJECT-TYPE
SYNTAX Fs6374LMStatsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The object specifies the loss Statistics table entry."
INDEX { fs6374ContextId,
fs6374ServiceName,
fs6374LMSessionId
}
::= { fs6374LMStatsTable 1 }
Fs6374LMStatsTableEntry ::= SEQUENCE {
fs6374LMStatsMplsType INTEGER,
fs6374LMStatsFwdTnlIdOrPwId Unsigned32,
fs6374LMStatsRevTnlId Unsigned32,
fs6374LMStatsSrcIpAddr OCTET STRING,
fs6374LMStatsDestIpAddr OCTET STRING,
fs6374LMStatsTrafficClass INTEGER,
fs6374LMStatsMode INTEGER,
fs6374LMStatsMethod INTEGER,
fs6374LMStatsType INTEGER,
fs6374LMStatsTimeStampFormat FS6374TimeStampFormat,
fs6374LMStatsStartTime Unsigned32,
fs6374LMStatsFarEndLossMin Unsigned32,
fs6374LMStatsFarEndLossMax Unsigned32,
fs6374LMStatsFarEndLossAvg Unsigned32,
fs6374LMStatsNearEndLossMin Unsigned32,
fs6374LMStatsNearEndLossMax Unsigned32,
fs6374LMStatsNearEndLossAvg Unsigned32,
fs6374LMStatsTxPktCount Unsigned32,
fs6374LMStatsRxPktCount Unsigned32,
fs6374LMStatsThroughputpercent OCTET STRING,
fs6374LMStatsResponseErrors Unsigned32,
fs6374LMStatsResponseTimeout Unsigned32,
fs6374LMStatsMeasurementOnGoing INTEGER,
fs6374LMDyadicMeasurement INTEGER,
fs6374LMRemoteSessionId Unsigned32,
fs6374LMDyadicProactiveRole INTEGER,
fs6374IsLMBufferSQIEnabled TruthValue
}
fs6374LMStatsMplsType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the Mpls type which could be Tunnel/Lsp
or PW."
::= { fs6374LMStatsTableEntry 1 }
fs6374LMStatsFwdTnlIdOrPwId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the Tunnel Id for unidirectional in forward
direction or PW Id based on Mpls type."
::= { fs6374LMStatsTableEntry 2 }
fs6374LMStatsRevTnlId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the Tunnel Id for unidirectional in
reverse direction."
::= { fs6374LMStatsTableEntry 3 }
fs6374LMStatsSrcIpAddr OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..40))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the source IP Address."
::= { fs6374LMStatsTableEntry 4 }
fs6374LMStatsDestIpAddr OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..40))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the destination IP Address."
::= { fs6374LMStatsTableEntry 5 }
fs6374LMStatsTrafficClass OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the traffic class."
::= { fs6374LMStatsTableEntry 6 }
fs6374LMStatsMode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the method (ondemand or proactive) used for LM.
This is not applicable for one-way type."
::= { fs6374LMStatsTableEntry 7 }
fs6374LMStatsMethod OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the method (inferred or direct) used for LM."
::= { fs6374LMStatsTableEntry 8 }
fs6374LMStatsType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the type (oneWay or twoWay) used for LM."
::= { fs6374LMStatsTableEntry 9 }
fs6374LMStatsTimeStampFormat OBJECT-TYPE
SYNTAX FS6374TimeStampFormat
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the value of timestamp format for the LM."
::= { fs6374LMStatsTableEntry 10 }
fs6374LMStatsStartTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the time at which loss measurement starts."
::= { fs6374LMStatsTableEntry 11 }
fs6374LMStatsFarEndLossMin OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum value of far-end loss."
::= { fs6374LMStatsTableEntry 12 }
fs6374LMStatsFarEndLossMax OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the maxmium value of far-end loss."
::= { fs6374LMStatsTableEntry 13 }
fs6374LMStatsFarEndLossAvg OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the average of the far-end loss measured
for a transaction."
::= { fs6374LMStatsTableEntry 14 }
fs6374LMStatsNearEndLossMin OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum value of near-end loss."
::= { fs6374LMStatsTableEntry 15 }
fs6374LMStatsNearEndLossMax OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the maxmium value of near-end loss."
::= { fs6374LMStatsTableEntry 16 }
fs6374LMStatsNearEndLossAvg OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the average of the near-end loss measured
for a transaction."
::= { fs6374LMStatsTableEntry 17 }
fs6374LMStatsTxPktCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of frames with loss information
sent for a transaction."
::= { fs6374LMStatsTableEntry 18 }
fs6374LMStatsRxPktCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of frames with loss information
received for a transaction."
::= { fs6374LMStatsTableEntry 19 }
fs6374LMStatsThroughputpercent OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the throughput loss value for a transaction."
::= { fs6374LMStatsTableEntry 20 }
fs6374LMStatsResponseErrors OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of responses dropped due to
errors."
DEFVAL {0}
::= { fs6374LMStatsTableEntry 21 }
fs6374LMStatsResponseTimeout OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of queries Timedout."
DEFVAL {0}
::= { fs6374LMStatsTableEntry 22 }
fs6374LMStatsMeasurementOnGoing OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies whether for the particular session,
measurement is ongoing or not.
Complete(0) Indicates measurement is ongoing.
OnGoing(1) Indicates measurement has been completed.
Aborted(2) Indicates if the measurement is Stop by user or
if the measurement is aborted due to MPLS path Down"
DEFVAL {0}
::= { fs6374LMStatsTableEntry 23 }
fs6374LMDyadicMeasurement OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the Loss Calculation done over
dyadic Measurement
enable(1) Indicates that Loss over Dyadic
disable(2) Indicates normal loss measurement."
DEFVAL {2}
::= { fs6374LMStatsTableEntry 24 }
fs6374LMRemoteSessionId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies Remote Session ID for the Loss/Comb LMDM
calculation done over dyadic Measurement."
::= { fs6374LMStatsTableEntry 25 }
fs6374LMDyadicProactiveRole OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the Loss Calculation done
for which Dyadic proactive role."
::= { fs6374LMStatsTableEntry 26 }
fs6374IsLMBufferSQIEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies whether the SQI was enabled or disabled
for the corresponding session when the LM buffer was created.
A value of 'true' indicates that SQI was enabled for that service
during that particular session. A value of 'false' indicates that
SQI was disabled for that service during that particular session."
DEFVAL { false }
::= { fs6374LMStatsTableEntry 27 }
--------------------------------------------------------------------------------------
--End of Buffers for storing the summary of LM calculations
--------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------
--Start of Buffers for storing the summary of DM calculations
--------------------------------------------------------------------------------------
fs6374DMStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF Fs6374DMStatsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the table which holds the summary of delay
information based on Service name and Session Id."
::= { fs6374DMStats 1 }
fs6374DMStatsTableEntry OBJECT-TYPE
SYNTAX Fs6374DMStatsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the delay Statistics table entry."
INDEX { fs6374ContextId,
fs6374ServiceName,
fs6374DMSessionId
}
::= { fs6374DMStatsTable 1 }
Fs6374DMStatsTableEntry ::= SEQUENCE {
fs6374DMStatsMplsType INTEGER,
fs6374DMStatsFwdTnlIdOrPwId Unsigned32,
fs6374DMStatsRevTnlId Unsigned32,
fs6374DMStatsSrcIpAddr OCTET STRING,
fs6374DMStatsDestIpAddr OCTET STRING,
fs6374DMStatsTrafficClass INTEGER,
fs6374DMStatsMode INTEGER,
fs6374DMStatsType INTEGER,
fs6374DMStatsTimeStampFormat FS6374TimeStampFormat,
fs6374DMStatsStartTime Unsigned32,
fs6374DMStatsMinDelay FS6374TimeRepresentation,
fs6374DMStatsMaxDelay FS6374TimeRepresentation,
fs6374DMStatsAvgDelay FS6374TimeRepresentation,
fs6374DMStatsMinRTDelay FS6374TimeRepresentation,
fs6374DMStatsMaxRTDelay FS6374TimeRepresentation,
fs6374DMStatsAvgRTDelay FS6374TimeRepresentation,
fs6374DMStatsMinIPDV FS6374TimeRepresentation,
fs6374DMStatsMaxIPDV FS6374TimeRepresentation,
fs6374DMStatsAvgIPDV FS6374TimeRepresentation,
fs6374DMStatsMinPDV FS6374TimeRepresentation,
fs6374DMStatsMaxPDV FS6374TimeRepresentation,
fs6374DMStatsAvgPDV FS6374TimeRepresentation,
fs6374DMStatsTxPktCount Unsigned32,
fs6374DMStatsRxPktCount Unsigned32,
fs6374DMStatsResponseErrors Unsigned32,
fs6374DMStatsResponseTimeout Unsigned32,
fs6374DMStatsMeasurementOnGoing INTEGER,
fs6374DMDyadicMeasurement INTEGER,
fs6374DMRemoteSessionId Unsigned32,
fs6374DMDyadicProactiveRole INTEGER,
fs6374DMStatsPaddingSize Unsigned32,
fs6374IsDMBufferSQIEnabled TruthValue
}
fs6374DMStatsMplsType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the MPLS type which could be Tunnel/LSP
or PW."
::= { fs6374DMStatsTableEntry 1 }
fs6374DMStatsFwdTnlIdOrPwId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the tunnel Id for unidirectional in forward
direction or PW Id based on Mpls type."
::= { fs6374DMStatsTableEntry 2 }
fs6374DMStatsRevTnlId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the tunnel Id for unidirectional in reverse
direction."
::= { fs6374DMStatsTableEntry 3 }
fs6374DMStatsSrcIpAddr OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..40))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the source IP Address."
::= { fs6374DMStatsTableEntry 4 }
fs6374DMStatsDestIpAddr OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..40))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the destination IP Address."
::= { fs6374DMStatsTableEntry 5 }
fs6374DMStatsTrafficClass OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the traffic class."
::= { fs6374DMStatsTableEntry 6 }
fs6374DMStatsMode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the method (ondemand or proactive) used for DM.
This is not applicable for one-way type."
::= { fs6374DMStatsTableEntry 7 }
fs6374DMStatsType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies type (oneWay or twoWay) used for DM."
::= { fs6374DMStatsTableEntry 8 }
fs6374DMStatsTimeStampFormat OBJECT-TYPE
SYNTAX FS6374TimeStampFormat
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the value of timestamp format for the DM."
::= { fs6374DMStatsTableEntry 9 }
fs6374DMStatsStartTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the time at which delay measurement starts."
::= { fs6374DMStatsTableEntry 10 }
fs6374DMStatsMinDelay OBJECT-TYPE
SYNTAX FS6374TimeRepresentation
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum value of delay."
::= { fs6374DMStatsTableEntry 11 }
fs6374DMStatsMaxDelay OBJECT-TYPE
SYNTAX FS6374TimeRepresentation
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the maximum value of frame-delay."
::= { fs6374DMStatsTableEntry 12 }
fs6374DMStatsAvgDelay OBJECT-TYPE
SYNTAX FS6374TimeRepresentation
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the average delay measured for a one-way or
two-way delay measurement for a transaction."
::= { fs6374DMStatsTableEntry 13 }
fs6374DMStatsMinRTDelay OBJECT-TYPE
SYNTAX FS6374TimeRepresentation
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum value of round trip delay."
::= { fs6374DMStatsTableEntry 14 }
fs6374DMStatsMaxRTDelay OBJECT-TYPE
SYNTAX FS6374TimeRepresentation
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the maximum value of round trip delay."
::= { fs6374DMStatsTableEntry 15 }
fs6374DMStatsAvgRTDelay OBJECT-TYPE
SYNTAX FS6374TimeRepresentation
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the average delay measured for a round trip
delay measurement for a transaction."
::= { fs6374DMStatsTableEntry 16 }
fs6374DMStatsMinIPDV OBJECT-TYPE
SYNTAX FS6374TimeRepresentation
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum value of IPDV."
::= { fs6374DMStatsTableEntry 17 }
fs6374DMStatsMaxIPDV OBJECT-TYPE
SYNTAX FS6374TimeRepresentation
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the maximum value of IPDV."
::= { fs6374DMStatsTableEntry 18 }
fs6374DMStatsAvgIPDV OBJECT-TYPE
SYNTAX FS6374TimeRepresentation
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the average delay measured for a IPDV."
::= { fs6374DMStatsTableEntry 19 }
fs6374DMStatsMinPDV OBJECT-TYPE
SYNTAX FS6374TimeRepresentation
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum value of PDV."
::= { fs6374DMStatsTableEntry 20 }
fs6374DMStatsMaxPDV OBJECT-TYPE
SYNTAX FS6374TimeRepresentation
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the maximum value of PDV."
::= { fs6374DMStatsTableEntry 21 }
fs6374DMStatsAvgPDV OBJECT-TYPE
SYNTAX FS6374TimeRepresentation
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the average delay measured for a PDV."
::= { fs6374DMStatsTableEntry 22 }
fs6374DMStatsTxPktCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the count of transmitted DM packets."
::= { fs6374DMStatsTableEntry 23 }
fs6374DMStatsRxPktCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the count of received DM packets."
::= { fs6374DMStatsTableEntry 24 }
fs6374DMStatsResponseErrors OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of Responses dropped due to errors."
DEFVAL {0}
::= { fs6374DMStatsTableEntry 25 }
fs6374DMStatsResponseTimeout OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of queries timedout."
DEFVAL {0}
::= { fs6374DMStatsTableEntry 26 }
fs6374DMStatsMeasurementOnGoing OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies whether for the particular session,
measurement is ongoing or not.
Complete(0) Indicates measurement is ongoing.
OnGoing(1) Indicates measurement has been completed.
Aborted(2) Indicates if the measurement is Stop by user or
if the measurement is aborted due to MPLS path Down"
DEFVAL {0}
::= { fs6374DMStatsTableEntry 27 }
fs6374DMDyadicMeasurement OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the Delay Calculation done over
dyadic Measurement
enable(1) Indicates that Delay over Dyadic
disable(2) Indicates normal Delay measurement."
DEFVAL {2}
::= { fs6374DMStatsTableEntry 28 }
fs6374DMRemoteSessionId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies Remote Session ID for the Delay/Comb LMDM
calculation done over dyadic Measurement."
::= { fs6374DMStatsTableEntry 29 }
fs6374DMDyadicProactiveRole OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the Delay Calculation done
for which Dyadic proactive role."
::= { fs6374DMStatsTableEntry 30 }
fs6374DMStatsPaddingSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the Delay Calculation done
for which Padding size."
::= { fs6374DMStatsTableEntry 31 }
fs6374IsDMBufferSQIEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies whether the SQI was enabled or disabled
for the corresponding session when the DM buffer was created.
A value of 'true' indicates that SQI was enabled for that service
during that particular session. A value of 'false' indicates that
SQI was disabled for that service during that particular session."
DEFVAL { false }
::= { fs6374DMStatsTableEntry 32 }
--------------------------------------------------------------------------------------
--End of Buffers for storing the summary of DM calculations
--------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------
--Start of 6374 per context statistics table
--------------------------------------------------------------------------------------
fs6374StatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF Fs6374StatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the list of per virtual context 6374 Module Statistics."
::= { fs6374Stats 1 }
fs6374StatsTableEntry OBJECT-TYPE
SYNTAX Fs6374StatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the Per virtual context 6374 Module Statistics."
INDEX { fs6374ContextId,
fs6374ServiceName }
::= { fs6374StatsTable 1 }
Fs6374StatsEntry ::= SEQUENCE {
fs6374StatsLmmOut Unsigned32,
fs6374StatsLmmIn Unsigned32,
fs6374StatsLmrOut Unsigned32,
fs6374StatsLmrIn Unsigned32,
fs6374Stats1LmOut Unsigned32,
fs6374Stats1LmIn Unsigned32,
fs6374Stats1DmOut Unsigned32,
fs6374Stats1DmIn Unsigned32,
fs6374StatsDmmOut Unsigned32,
fs6374StatsDmmIn Unsigned32,
fs6374StatsDmrOut Unsigned32,
fs6374StatsDmrIn Unsigned32,
fs6374StatsCmb1LmDmOut Unsigned32,
fs6374StatsCmb1LmDmIn Unsigned32,
fs6374StatsCmbLmmDmmOut Unsigned32,
fs6374StatsCmbLmmDmmIn Unsigned32,
fs6374StatsCmbLmrDmrOut Unsigned32,
fs6374StatsCmbLmrDmrIn Unsigned32
}
fs6374StatsLmmOut OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the number of LMM PDUs transmitted."
::= { fs6374StatsTableEntry 1 }
fs6374StatsLmmIn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the number of LMM PDUs received."
::= { fs6374StatsTableEntry 2 }
fs6374StatsLmrOut OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the number of LMR PDUs transmitted."
::= { fs6374StatsTableEntry 3 }
fs6374StatsLmrIn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the number of LMR PDUs received."
::= { fs6374StatsTableEntry 4 }
fs6374Stats1LmOut OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the number of 1LM PDUs transmitted."
::= { fs6374StatsTableEntry 5 }
fs6374Stats1LmIn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the number of 1LM PDUs received."
::= { fs6374StatsTableEntry 6 }
fs6374Stats1DmOut OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the number of 1DM PDUs transmitted."
::= { fs6374StatsTableEntry 7 }
fs6374Stats1DmIn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the number of 1DM PDUs received."
::= { fs6374StatsTableEntry 8 }
fs6374StatsDmmOut OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the number of DMM PDUs transmitted."
::= { fs6374StatsTableEntry 9 }
fs6374StatsDmmIn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the number of DMM PDUs received."
::= { fs6374StatsTableEntry 10 }
fs6374StatsDmrOut OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the number of DMR PDUs transmitted."
::= { fs6374StatsTableEntry 11 }
fs6374StatsDmrIn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the number of DMR PDUs received."
::= { fs6374StatsTableEntry 12 }
fs6374StatsCmb1LmDmOut OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of combined LMDM one way PDUs
transmitted."
::= { fs6374StatsTableEntry 13 }
fs6374StatsCmb1LmDmIn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of combined LMDM one way PDUs
received."
::= { fs6374StatsTableEntry 14 }
fs6374StatsCmbLmmDmmOut OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of combined LMDM two way PDUs
transmitted."
::= { fs6374StatsTableEntry 15 }
fs6374StatsCmbLmmDmmIn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of combined LMDM two way PDUs
received."
::= { fs6374StatsTableEntry 16 }
fs6374StatsCmbLmrDmrOut OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of combined LMR DMR two way PDUs
transmitted."
::= { fs6374StatsTableEntry 17 }
fs6374StatsCmbLmrDmrIn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of combined LMR DMR two ways PDUs
received."
::= { fs6374StatsTableEntry 18 }
--------------------------------------------------------------------------------------
--End of 6374 per context statistics table
--------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------
--Start of System level config table
--------------------------------------------------------------------------------------
fs6374SystemConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Fs6374SystemConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the table that contains system level
information."
::= { fs6374SystemConfig 1 }
fs6374SystemConfigEntry OBJECT-TYPE
SYNTAX Fs6374SystemConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the SystemConfig entry."
INDEX { fs6374ContextId
}
::= { fs6374SystemConfigTable 1 }
Fs6374SystemConfigEntry ::= SEQUENCE {
fs6374SystemControl INTEGER,
fs6374ModuleStatus INTEGER,
fs6374DMBufferClear TruthValue,
fs6374LMBufferClear TruthValue,
fs6374DebugLevel Unsigned32,
fs6374TSFormatSupported FS6374SuppTimeStampFormat
}
fs6374SystemControl OBJECT-TYPE
SYNTAX INTEGER {
start (1),
shutdown (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the administrative system control status of
6374 module.
The value 'start' (1) indicates that all
resources required by the module should be allocated
and 6374 should be supported in the device on all ports.
The value 'shutdown' (2) indicates that 6374 should be
shutdown in the device on all ports and all allocated
memory must be released."
DEFVAL { start }
::= { fs6374SystemConfigEntry 1 }
fs6374ModuleStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the administrative module status of 6374 module.
This enables or disables 6374 in the system.
A value of 'enabled' (1) indicates that 6374 is
enabled in the device. A value of 'disabled'
(2) indicates that 6374 is disabled in the device."
DEFVAL { enabled }
::= { fs6374SystemConfigEntry 2 }
fs6374DMBufferClear OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the trigger to remove the contents of Buffer
maintained for storing delay measured at various times.
Note: Get operation value should be ignored."
::= { fs6374SystemConfigEntry 3 }
fs6374LMBufferClear OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the trigger to remove the contents of Buffer
maintained for storing loss measured at various times.
Note: Get operation value should be ignored."
::= { fs6374SystemConfigEntry 4 }
fs6374DebugLevel OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable the tracing in the selected submodule.
A 32 bit integer is used to store the Tracing level in the specified
module.
Different Tracing Levels -
BIT 0 - Initialisation and Shutdown Trace.
BIT 1 - Management trace.
BIT 2 - Critical trace.
BIT 3 - Control plane.
BIT 4 - Packet Dump.
BIT 5 - OS Resource trace.
BIT 6 - All Failure trace (All failures including Packet Validation).
BIT 7 - Function Entry.
BIT 8 - Function Exit.
Note : BIT0 is the least significant bit and BIT31 is the most
significant bit.
By default, critical trace(bit 3) is set."
DEFVAL { '00000003'H }
::= { fs6374SystemConfigEntry 5 }
fs6374TSFormatSupported OBJECT-TYPE
SYNTAX FS6374SuppTimeStampFormat
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the timestamp format supported in the system.
The below specified timestamp formats are supported in the system.
timeStampFormatNTP (2),
timeStampFormatIEEE1588 (3)
When the object 'fs6374TSFNegotiation' is enabled in the service,
the supported timestamp formats will be used for negotiation process."
::= { fs6374SystemConfigEntry 6 }
--------------------------------------------------------------------------------------
--End of System level config table
--------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------
--Start of Traps
--------------------------------------------------------------------------------------
fs6374NotificationsTable OBJECT-TYPE
SYNTAX SEQUENCE OF Fs6374NotificationsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the list of Traps supported in 6374."
::= { fs6374Notifications 1 }
fs6374NotificationsEntry OBJECT-TYPE
SYNTAX Fs6374NotificationsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the notification entry."
INDEX { fs6374ContextId }
::= { fs6374NotificationsTable 1 }
Fs6374NotificationsEntry ::= SEQUENCE {
fs6374LMDMTrapControl FS6374Traps
}
fs6374LMDMTrapControl OBJECT-TYPE
SYNTAX FS6374Traps
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies a vector of Boolean notification types,
used to enable or disable the LM&DM Traps:
bTrapUnsupportedVersion (1),
bTrapUnsupportedControlCode (2),
bTrapUnsupportedDataFormat (3),
bTrapConnectionMismatch (4),
bTrapUnsupportedMandatoryTLVObject (5),
bTrapUnsupportedTimeStamp (6),
bTrapResponseTimeout (7),
bTrapResourceUnavailable (8),
bTrapTestAbort (9),
bTrapProactiveTestRestart(10),
bTrapUnsupportedQueryInterval(11)
"
::= { fs6374NotificationsEntry 1 }