ALPHA-INVERTER-SYS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
--==========================================================================
|
|
--
|
|
-- Alpha Technologies Ltd.
|
|
-- Copyright 2014
|
|
--
|
|
--==========================================================================
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE
|
|
FROM SNMPv2-SMI
|
|
ScaledNumber, simple
|
|
FROM ALPHA-RESOURCE-MIB
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF;
|
|
|
|
inverterSystem MODULE-IDENTITY
|
|
LAST-UPDATED "201602290000Z"
|
|
ORGANIZATION "Alpha Technologies Ltd."
|
|
CONTACT-INFO
|
|
"Alpha Technologies Ltd.
|
|
7700 Riverfront Gate
|
|
Burnaby, BC V5J 5M4
|
|
Canada
|
|
|
|
Tel: 1-604-436-5900
|
|
Fax: 1-604-436-1233"
|
|
DESCRIPTION
|
|
"
|
|
This MIB provides a flat list of data points available from the Cordex HP controller
|
|
to present information of one Inverter System.
|
|
"
|
|
|
|
REVISION "201602290000Z" -- February 29, 2016
|
|
DESCRIPTION
|
|
"General revision."
|
|
|
|
::= { simple 3 }
|
|
|
|
--==========================================================================
|
|
-- Subfolders for Phase, AC Input and DC Input groups.
|
|
--==========================================================================
|
|
|
|
phaseGroup OBJECT IDENTIFIER ::= { inverterSystem 80 }
|
|
acInputGroup OBJECT IDENTIFIER ::= { inverterSystem 81 }
|
|
dcInputGroup OBJECT IDENTIFIER ::= { inverterSystem 82 }
|
|
|
|
|
|
-- Inverter System data points
|
|
|
|
invTotalAcOutputPowerVa OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total output power summed from all the phases (VA)."
|
|
::= { inverterSystem 1 }
|
|
|
|
invSysAverageLoadingOfInstalledPowerVa OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average output loading of all phases (% VA). "
|
|
::= { inverterSystem 2 }
|
|
|
|
invSysAverageDcInputToOutputPowerRatio OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the output that is taken from the DC input (%)."
|
|
::= { inverterSystem 3 }
|
|
|
|
invSysSystemMode OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The mode of the system. See manual for decoding the number."
|
|
::= { inverterSystem 4 }
|
|
|
|
invSysPhase1OutputPowerVa OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total output power from the phase 1 (VA)."
|
|
::= { inverterSystem 5 }
|
|
|
|
invSysPhase2OutputPowerVa OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total output power from phase 2 (VA)."
|
|
::= { inverterSystem 6 }
|
|
|
|
invSysPhase3OutputPowerVa OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total output power from the phase 3 (VA)."
|
|
::= { inverterSystem 7 }
|
|
|
|
invSysAverageOutputVoltageMeasured OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average output voltage of all the phases (V)."
|
|
::= { inverterSystem 8 }
|
|
|
|
invSysEnabledDisconnects OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of disconnects that are enabled."
|
|
::= { inverterSystem 9 }
|
|
|
|
invSysActivatedDisconnects OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of disconnects that are active."
|
|
::= { inverterSystem 10 }
|
|
|
|
invSysTotalDCInputCurrent OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total DC input current for the inverter system (A)."
|
|
::= { inverterSystem 11 }
|
|
|
|
invSysAverageDcInputVoltage OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average DC input voltage reading for the inverter system (V)."
|
|
::= { inverterSystem 12 }
|
|
|
|
invSysTotalDcInputPower OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total DC input power reading for the inverter system (W)."
|
|
::= { inverterSystem 13 }
|
|
|
|
invSysSystemOnBypass OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"True when the bypass switch is on. The AC input from the grid is fed to the AC load directly."
|
|
::= { inverterSystem 14 }
|
|
|
|
invSysTotalAcInputPowerVa OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total AC input power reading of the Inverter System (VA)."
|
|
::= { inverterSystem 18 }
|
|
|
|
|
|
-- Phase Group
|
|
|
|
invSysAcPhaseCount OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
"
|
|
::= { phaseGroup 1 }
|
|
|
|
invSysAcPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF InvSysAcPhaseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
"
|
|
::= { phaseGroup 2 }
|
|
|
|
invSysAcPhaseEntry OBJECT-TYPE
|
|
SYNTAX InvSysAcPhaseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
"
|
|
INDEX { invSysAcPhaseCount }
|
|
::= { invSysAcPhaseTable 1 }
|
|
|
|
InvSysAcPhaseEntry ::= SEQUENCE {
|
|
invSysAcPhaseAcOutputPowerVa ScaledNumber,
|
|
invSysAcPhaseOutputVoltageMeasured ScaledNumber,
|
|
invSysAcPhaseOutputCurrent ScaledNumber,
|
|
invSysAcPhaseFrequency ScaledNumber,
|
|
invSysAcPhaseLoadingOfInstalledPowerVa ScaledNumber,
|
|
invSysAcPhaseNumberOfModulesOn ScaledNumber,
|
|
invSysAcPhaseLoadingOfInstalledPowerWatts ScaledNumber,
|
|
invSysAcPhaseDcInputToOutputPowerRatioMeasured ScaledNumber,
|
|
invSysAcPhaseAcInputPowerWatts ScaledNumber,
|
|
invSysAcPhaseAcInputPowerVa ScaledNumber,
|
|
invSysAcPhaseAcOutputPowerWatts ScaledNumber,
|
|
invSysAcPhaseDCInputPowerWatts ScaledNumber,
|
|
invSysAcPhaseNumberOfRedundantModulesMeasured ScaledNumber,
|
|
invSysAcPhaseNumberOfModulesDetected ScaledNumber,
|
|
invSysAcPhaseNumberOfModulesOff ScaledNumber,
|
|
invSysAcPhaseNumberOfModulesFailed ScaledNumber
|
|
}
|
|
|
|
invSysAcPhaseAcOutputPowerVa OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power of the AC output (VA)."
|
|
::= { invSysAcPhaseEntry 1 }
|
|
|
|
invSysAcPhaseOutputVoltageMeasured OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output voltage of the phase or inverter (V)."
|
|
::= { invSysAcPhaseEntry 2 }
|
|
|
|
invSysAcPhaseOutputCurrent OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output current of the phase or inverter (A)."
|
|
::= { invSysAcPhaseEntry 3 }
|
|
|
|
invSysAcPhaseFrequency OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Frequency to which the inverters will lock (Hz)."
|
|
::= { invSysAcPhaseEntry 4 }
|
|
|
|
invSysAcPhaseLoadingOfInstalledPowerVa OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ratio of output load to installed power (%VA)."
|
|
::= { invSysAcPhaseEntry 5 }
|
|
|
|
invSysAcPhaseNumberOfModulesOn OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of inverters that are On and can deliver power."
|
|
::= { invSysAcPhaseEntry 6 }
|
|
|
|
invSysAcPhaseLoadingOfInstalledPowerWatts OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ratio of output load to installed power (% W)."
|
|
::= { invSysAcPhaseEntry 7 }
|
|
|
|
invSysAcPhaseDcInputToOutputPowerRatioMeasured OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The measured percentage of DC input power to output power(%). Under light or no load this value will not computed accurately."
|
|
::= { invSysAcPhaseEntry 8 }
|
|
|
|
invSysAcPhaseAcInputPowerWatts OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power drawn by the AC input (W)."
|
|
::= { invSysAcPhaseEntry 9 }
|
|
|
|
invSysAcPhaseAcInputPowerVa OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power drawn by the AC input (VA)."
|
|
::= { invSysAcPhaseEntry 10 }
|
|
|
|
invSysAcPhaseAcOutputPowerWatts OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power of the AC output (W)."
|
|
::= { invSysAcPhaseEntry 11 }
|
|
|
|
invSysAcPhaseDCInputPowerWatts OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power drawn by the DC input (W)."
|
|
::= { invSysAcPhaseEntry 12 }
|
|
|
|
invSysAcPhaseNumberOfRedundantModulesMeasured OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of inverters currently unneeded by the load."
|
|
::= { invSysAcPhaseEntry 13 }
|
|
|
|
invSysAcPhaseNumberOfModulesDetected OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of inverters assigned to this phase that the T2S has detected."
|
|
::= { invSysAcPhaseEntry 14 }
|
|
|
|
invSysAcPhaseNumberOfModulesOff OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of inverters that are manually turned off."
|
|
::= { invSysAcPhaseEntry 15 }
|
|
|
|
invSysAcPhaseNumberOfModulesFailed OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of inverters that have failed and cannot deliver power."
|
|
::= { invSysAcPhaseEntry 16 }
|
|
|
|
|
|
-- AC Input Group
|
|
|
|
invSysAcInputCount OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
"
|
|
::= { acInputGroup 1 }
|
|
|
|
invSysAcInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF InvSysAcInputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
"
|
|
::= { acInputGroup 2 }
|
|
|
|
invSysAcInputEntry OBJECT-TYPE
|
|
SYNTAX InvSysAcInputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
"
|
|
INDEX { invSysAcInputCount }
|
|
::= { invSysAcInputTable 1 }
|
|
|
|
InvSysAcInputEntry ::= SEQUENCE {
|
|
invSysAcInputInputVoltage ScaledNumber,
|
|
invSysAcInputInputCurrent ScaledNumber,
|
|
invSysAcInputFrequency ScaledNumber,
|
|
invSysAcInputAcInputPowerVa ScaledNumber,
|
|
invSysAcInputNumberOfModulesOn ScaledNumber,
|
|
invSysAcInputAcInputPowerWatts ScaledNumber,
|
|
invSysAcInputNumberOfModulesDetected ScaledNumber,
|
|
invSysAcInputNumberOfModulesOff ScaledNumber,
|
|
invSysAcInputNumberOfModulesFailed ScaledNumber
|
|
}
|
|
|
|
invSysAcInputInputVoltage OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input voltage of the inverter or group (V)."
|
|
::= { invSysAcInputEntry 1 }
|
|
|
|
invSysAcInputInputCurrent OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input current of the inverter or group (A)."
|
|
::= { invSysAcInputEntry 2 }
|
|
|
|
invSysAcInputFrequency OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The frequency of the input voltage and current of the inverter or group (Hz)."
|
|
::= { invSysAcInputEntry 3 }
|
|
|
|
invSysAcInputAcInputPowerVa OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power drawn by the AC input (VA)."
|
|
::= { invSysAcInputEntry 4 }
|
|
|
|
invSysAcInputNumberOfModulesOn OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of inverters that are On and can deliver power."
|
|
::= { invSysAcInputEntry 5 }
|
|
|
|
invSysAcInputAcInputPowerWatts OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power drawn by the AC input (W)."
|
|
::= { invSysAcInputEntry 6 }
|
|
|
|
invSysAcInputNumberOfModulesDetected OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of inverters assigned to this phase that the T2S has detected."
|
|
::= { invSysAcInputEntry 7 }
|
|
|
|
invSysAcInputNumberOfModulesOff OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of inverters that are manually turned off."
|
|
::= { invSysAcInputEntry 8 }
|
|
|
|
invSysAcInputNumberOfModulesFailed OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of inverters that have failed and cannot deliver power."
|
|
::= { invSysAcInputEntry 9 }
|
|
|
|
|
|
-- DC Input Group
|
|
|
|
invSysDcInputCount OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
"
|
|
::= { dcInputGroup 1 }
|
|
|
|
invSysDcInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF InvSysDcInputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
"
|
|
::= { dcInputGroup 2 }
|
|
|
|
invSysDcInputEntry OBJECT-TYPE
|
|
SYNTAX InvSysDcInputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
"
|
|
INDEX { invSysDcInputCount }
|
|
::= { invSysDcInputTable 1 }
|
|
|
|
InvSysDcInputEntry ::= SEQUENCE {
|
|
invSysDcInputInputVoltage ScaledNumber,
|
|
invSysDcInputInputCurrent ScaledNumber,
|
|
invSysDcInputDcInputPowerWatts ScaledNumber,
|
|
invSysDcInputNumberOfModulesOn ScaledNumber,
|
|
invSysDcInputNumberOfModulesOff ScaledNumber,
|
|
invSysDcInputNumberOfModulesFailed ScaledNumber,
|
|
invSysDcInputNumberOfModulesDetected ScaledNumber
|
|
}
|
|
|
|
|
|
invSysDcInputInputVoltage OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input voltage of the inverter or group (V)."
|
|
::= { invSysDcInputEntry 1 }
|
|
|
|
invSysDcInputInputCurrent OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input current of the inverter or group (A)."
|
|
::= { invSysDcInputEntry 2 }
|
|
|
|
invSysDcInputDcInputPowerWatts OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power drawn by the DC input (W)."
|
|
::= { invSysDcInputEntry 3 }
|
|
|
|
invSysDcInputNumberOfModulesOn OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of inverters that are On and can deliver power."
|
|
::= { invSysDcInputEntry 4 }
|
|
|
|
invSysDcInputNumberOfModulesOff OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of inverters that are manually turned off."
|
|
::= { invSysDcInputEntry 5 }
|
|
|
|
invSysDcInputNumberOfModulesFailed OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of inverters that have failed and cannot deliver power."
|
|
::= { invSysDcInputEntry 6 }
|
|
|
|
invSysDcInputNumberOfModulesDetected OBJECT-TYPE
|
|
SYNTAX ScaledNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of inverters assigned to this phase that the T2S has detected."
|
|
::= { invSysDcInputEntry 7 }
|
|
|
|
END
|