2306 lines
80 KiB
Plaintext
2306 lines
80 KiB
Plaintext
ADTRAN-TA5K-SM-MIB
|
|
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
-- TITLE: The ADTRAN Total Access TA5000 SM MIB
|
|
-- PRODUCT: 1187020L1
|
|
-- VERSION: 1.0
|
|
-- DATE: Dec 12, 2006
|
|
|
|
-- This MIB Contains tables specific to the TA5000 SM
|
|
--
|
|
|
|
-- MIBs supported:
|
|
|
|
-- HISTORY:
|
|
-- 05/08/18 tpm First edition: Node, SFP Data, Forwarding Control, Aggregation,
|
|
-- Clocks, Metalic Test access
|
|
-- 09/27/06 aed Changed adTa5kSmCurrentClock from read-write to read-only.
|
|
-- 12/12/06 aed Added SM alarm definitions
|
|
-- 02/01/07 aed Added adTa5KSmFallbackClock. Added two new enum values for adTa5kSmCurrentClock.
|
|
-- 05/18/07 aed Added external clock quality and preference.
|
|
-- 08/31/07 aed Import sysName from SNMPv2-SMI, not RFC 1213.
|
|
-- 10/31/07 mguo changed "disable" from "0" to "1" on auto-negotiation.
|
|
-- 11/05/07 aed Add support for IGMP interface mode and S-Tag TPID.
|
|
-- Also, sysName should be imported from SNMPv2-MIB, not SNMPv2-SMI.
|
|
-- 11/19/07 aed Add SNMP support for new timing status items: hop count, quality, and priority.
|
|
-- Deprecated ExtA & ExtB preference provisioning items, because the range should be 0..255.
|
|
-- 12/13/07 mguo Add support for SFP internal information on NET1 and NET2.
|
|
-- 12/14/07 mguo Modified description of SFP TX/RX power levels from 0.1 dBm to 1 dBm.
|
|
-- 02/27/07 aed Deprecate the exisiting timing failure alarm and add two new alarms for primary
|
|
-- and secondary timing source failures.
|
|
-- 05/13/08 aed Add two new alarm notifications: node number defaulted to 0, and internal mgmt vlan bad.
|
|
-- 05/16/08 aed Modify the severity definitions for 5 alarms to match the SCM's alarm log severity.
|
|
-- 06/10/08 aed Add support for port mode and lacp mode. Correct typos in some description fields.
|
|
-- Deprecate adTa5kUpstreamChaining and adTa5kDownstreamChaining.
|
|
-- 09/29/08 aed Changes for SR4.1. Maximum number of nodes is now 64. Modify the description of adTa5kSmUplink
|
|
-- to include information for new SMs that have more than two faceplate ports.
|
|
-- 10/31/08 aed Deprecate Loss of Network STP alarm and Multiple Uplinks alarm.
|
|
-- 06/30/09 aed Deprecate SM-specific OIDs which have been replaced by new generic MIBs:
|
|
-- 1) Deprecate the OIDs related to SFPs, in favor of adGenPluggablePort.mi2
|
|
-- 2) Deprecate autonegotiation OIDS in favor of genEthIfc.mi2
|
|
-- 3) Deprecate SystemTiming OIDs in favor of adGenSystemTiming.mi2
|
|
-- 09/30/09 aed Deprecate system timing alarms. These alarms have been moved to adGenSystemTiming.mi2
|
|
-- 11/09/09 jmz Documented additional uplink values added in SR5.0.2
|
|
-- 01/29/09 jmz Documented additional port mode values added in SR5.0.2
|
|
-- 2011/02/02 aed Deprecated adTa5kSmPortMode. (It has been moved to adTa5kTreeNetworking.mi2)
|
|
-- Deprecated adTa5kSmLacpMode. (It has been moved to adTa5kLinkAggregation.mi2)
|
|
-- Added OIDS for provisioning the ethernet default interface.
|
|
-- Deprecate adTa5kSmUplink in favor of the ethernet default interface OIDs.
|
|
-- *** DO NOT ADD REVISION COMMENTS HERE ****
|
|
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
Integer32,
|
|
Counter32,
|
|
IpAddress,
|
|
-- Gauge32,
|
|
-- Counter64,
|
|
-- TimeTicks,
|
|
-- Unsigned32,
|
|
NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
|
|
sysName
|
|
FROM SNMPv2-MIB
|
|
|
|
ifIndex,
|
|
ifDescr,
|
|
InterfaceIndexOrZero
|
|
-- InterfaceIndex
|
|
FROM IF-MIB
|
|
|
|
DisplayString,
|
|
TruthValue,
|
|
RowStatus,
|
|
-- TimeInterval,
|
|
MacAddress,
|
|
TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
|
|
-- SnmpAdminString
|
|
-- FROM SNMP-FRAMEWORK-MIB
|
|
|
|
adIdentity,
|
|
adProducts,
|
|
adMgmt
|
|
FROM ADTRAN-MIB
|
|
|
|
-- IANAifType
|
|
-- FROM IANAifType-MIB
|
|
|
|
adTrapInformSeqNum
|
|
FROM ADTRAN-GENTRAPINFORM-MIB
|
|
|
|
adGenSlotInfoIndex
|
|
FROM ADTRAN-GENSLOT-MIB
|
|
|
|
adGenPortTrapIdentifier
|
|
FROM ADTRAN-GENPORT-MIB
|
|
|
|
adTAeSCUTrapAlarmLevel
|
|
FROM ADTRAN-TAeSCUEXT1-MIB;
|
|
|
|
|
|
|
|
-- *********************************************************************************************************
|
|
|
|
adTa5kSmModuleIdentity MODULE-IDENTITY
|
|
LAST-UPDATED "202110260000Z"
|
|
ORGANIZATION
|
|
"ADTRAN, Inc."
|
|
CONTACT-INFO
|
|
"CND Tech Support
|
|
Postal: ADTRAN, Inc.
|
|
901 Explorer Blvd.
|
|
Huntsville, AL 35806
|
|
Tel: +1 800 726-8663
|
|
Fax: +1 256 963 6217
|
|
E-mail: support@adtran.com"
|
|
DESCRIPTION
|
|
"Total Access 5000 SwitchModule 1187020L1 MIB"
|
|
|
|
REVISION "202110260000Z"
|
|
DESCRIPTION "Add support for Backplane Incompatible alarm."
|
|
|
|
REVISION "201905070000Z"
|
|
DESCRIPTION "Update TC for EthernetDefaultInterfaceType to include xGigabitEthernet."
|
|
|
|
REVISION "201708241050Z"
|
|
DESCRIPTION "Add support for SM's peer link down alarm."
|
|
|
|
REVISION "201410291100Z"
|
|
DESCRIPTION "Add support for the BpRateFallback alarm enables."
|
|
|
|
REVISION "201409171555Z"
|
|
DESCRIPTION "Add support for the new muxponderSlot type of Ethernet Default Interface."
|
|
|
|
REVISION "201404241000Z"
|
|
DESCRIPTION "Add support for the SM and SMIO hardware mismatch alarms."
|
|
|
|
REVISION "201110261100Z"
|
|
DESCRIPTION "Add support for the alarm enables."
|
|
|
|
REVISION "201110111400Z"
|
|
DESCRIPTION "Add support for the internal-system-s-tag"
|
|
|
|
REVISION "201104122107Z"
|
|
DESCRIPTION "Add the node number as a varbind for adTa5kSmDuplicateNodeClear and adTa5kSmDuplicateNodeActive."
|
|
::= { adIdentity 750 }
|
|
|
|
-- OBJECT IDENTIFIERS
|
|
adTa5kSm OBJECT IDENTIFIER ::= { adMgmt 750 }
|
|
adTa5kSmTraps OBJECT IDENTIFIER ::= { adProducts 750 }
|
|
adTa5kSmAlarms OBJECT IDENTIFIER ::= { adTa5kSmTraps 0 }
|
|
adTa5kSmConfig OBJECT IDENTIFIER ::= { adTa5kSm 1 }
|
|
adTa5kSmProv OBJECT IDENTIFIER ::= { adTa5kSm 2 }
|
|
adTa5kSmStatus OBJECT IDENTIFIER ::= { adTa5kSm 3 }
|
|
adTa5kSmTest OBJECT IDENTIFIER ::= { adTa5kSm 4 }
|
|
adTa5kSmPerfMon OBJECT IDENTIFIER ::= { adTa5kSm 5 }
|
|
adTa5kSmAtpMfg OBJECT IDENTIFIER ::= { adTa5kSm 6 }
|
|
|
|
|
|
-- ======================================================================
|
|
-- Config Menu Items
|
|
|
|
adTa5kSmSystemTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdTa5kSmSystemEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"..."
|
|
::= { adTa5kSmConfig 1 }
|
|
|
|
adTa5kSmSystemEntry OBJECT-TYPE
|
|
SYNTAX AdTa5kSmSystemEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"..."
|
|
INDEX { adGenSlotInfoIndex }
|
|
::= { adTa5kSmSystemTable 1 }
|
|
|
|
AdTa5kSmSystemEntry ::=
|
|
SEQUENCE {
|
|
adTa5kSmMaxNodes Integer32,
|
|
adTa5kSmMaxShelves Integer32,
|
|
adTa5kSmBootRev DisplayString,
|
|
adTa5kSmNet1SFPDescription DisplayString,
|
|
adTa5kSmNet2SFPDescription DisplayString,
|
|
adTa5kSmRingGenType INTEGER,
|
|
adTa5kSmSMIOType Integer32,
|
|
adTa5kSmNet1AutoNegoAdmnStat INTEGER,
|
|
adTa5kSmNet2AutoNegoAdmnStat INTEGER,
|
|
adTa5kSmNet1SFPVendorPartNumber DisplayString,
|
|
adTa5kSmNet1SFPVendorSerialNumber DisplayString,
|
|
adTa5kSmNet1SFPRxPowerLevel Integer32,
|
|
adTa5kSmNet1SFPTxPowerLevel Integer32,
|
|
adTa5kSmNet1SFPTxBias Integer32,
|
|
adTa5kSmNet1SFPTemperature Integer32,
|
|
adTa5kSmNet1SFPSupplyVoltage Integer32,
|
|
adTa5kSmNet2SFPVendorPartNumber DisplayString,
|
|
adTa5kSmNet2SFPVendorSerialNumber DisplayString,
|
|
adTa5kSmNet2SFPRxPowerLevel Integer32,
|
|
adTa5kSmNet2SFPTxPowerLevel Integer32,
|
|
adTa5kSmNet2SFPTxBias Integer32,
|
|
adTa5kSmNet2SFPTemperature Integer32,
|
|
adTa5kSmNet2SFPSupplyVoltage Integer32
|
|
}
|
|
|
|
adTa5kSmMaxNodes OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The max number of nodes supported in a topology of TA5000's. Value returned is only valid at the COT."
|
|
::= { adTa5kSmSystemEntry 1 }
|
|
|
|
adTa5kSmMaxShelves OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The max number of expansion shelves supported. Value returned is only valid at the COT."
|
|
::= { adTa5kSmSystemEntry 2 }
|
|
|
|
adTa5kSmBootRev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the boot revision"
|
|
::= { adTa5kSmSystemEntry 3 }
|
|
|
|
adTa5kSmNet1SFPDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..32))
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This displays the description stored in the Net 1 SFP internal ROM."
|
|
::= { adTa5kSmSystemEntry 4 }
|
|
|
|
adTa5kSmNet2SFPDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..32))
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This displays the description stored in the Net 2 SFP internal ROM"
|
|
::= { adTa5kSmSystemEntry 5 }
|
|
|
|
adTa5kSmRingGenType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
internal40REN (1),
|
|
external (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of ring generator that is used to produce ringing on pots and combo cards."
|
|
::= { adTa5kSmSystemEntry 6 }
|
|
|
|
adTa5kSmSMIOType OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of backplane interface that connects the Redundant SMs and optionally the SCM."
|
|
::= { adTa5kSmSystemEntry 7 }
|
|
|
|
adTa5kSmNet1AutoNegoAdmnStat OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This is enablement and disablement of auto negotiation of the Net1 PHY"
|
|
::= { adTa5kSmSystemEntry 8 }
|
|
|
|
adTa5kSmNet2AutoNegoAdmnStat OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This is enablement and disablement of auto negotiation of the Net2 PHY"
|
|
::= { adTa5kSmSystemEntry 9 }
|
|
|
|
adTa5kSmNet1SFPVendorPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the part-number stored in the Net 1 SFP internal ROM"
|
|
::= { adTa5kSmSystemEntry 10 }
|
|
|
|
adTa5kSmNet1SFPVendorSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This displays the serial number stored in the Net 1 SFP internal ROM"
|
|
::= { adTa5kSmSystemEntry 11 }
|
|
|
|
adTa5kSmNet1SFPRxPowerLevel OBJECT-TYPE
|
|
SYNTAX Integer32 (-7000..7000)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This displays transceiver RX power level in 1 dBm on the Net 1 SFP with SFF-8472 extensions"
|
|
::= { adTa5kSmSystemEntry 12 }
|
|
|
|
adTa5kSmNet1SFPTxPowerLevel OBJECT-TYPE
|
|
SYNTAX Integer32 (-7000..7000)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This displays transceiver TX power level in 1 dBm on the Net 1 SFP with SFF-8472 extensions"
|
|
::= { adTa5kSmSystemEntry 13 }
|
|
|
|
adTa5kSmNet1SFPTxBias OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This displays transceiver TX bias in 1 mA on the Net 1 SFP with SFF-8472 extensions"
|
|
::= { adTa5kSmSystemEntry 14 }
|
|
|
|
adTa5kSmNet1SFPTemperature OBJECT-TYPE
|
|
SYNTAX Integer32 (-80..140)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This displays the internal temperature in 1 Celsius on the Net 1 SFP with SFF-8472 extensions"
|
|
::= { adTa5kSmSystemEntry 15 }
|
|
|
|
adTa5kSmNet1SFPSupplyVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This displays the supply voltage in 1 mV on the Net 1 SFP with SFF-8472 extensions"
|
|
::= { adTa5kSmSystemEntry 16 }
|
|
|
|
|
|
adTa5kSmNet2SFPVendorPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This displays the vendor part-number stored in the Net 2 SFP internal ROM"
|
|
::= { adTa5kSmSystemEntry 17 }
|
|
|
|
adTa5kSmNet2SFPVendorSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This displays the vendor serial number stored in the Net 2 SFP internal ROM"
|
|
::= { adTa5kSmSystemEntry 18 }
|
|
|
|
adTa5kSmNet2SFPRxPowerLevel OBJECT-TYPE
|
|
SYNTAX Integer32 (-7000..7000)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This displays transceiver RX power level in 1 dBm on the Net 2 SFP with SFF-8472 extensions"
|
|
::= { adTa5kSmSystemEntry 19 }
|
|
|
|
adTa5kSmNet2SFPTxPowerLevel OBJECT-TYPE
|
|
SYNTAX Integer32 (-7000..7000)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This displays transceiver TX power level in 1 dBm on the Net 2 SFP with SFF-8472 extensions"
|
|
::= { adTa5kSmSystemEntry 20 }
|
|
|
|
adTa5kSmNet2SFPTxBias OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This displays transceiver TX bias in 1 mA on the Net 2 SFP with SFF-8472 extensions"
|
|
::= { adTa5kSmSystemEntry 21 }
|
|
|
|
adTa5kSmNet2SFPTemperature OBJECT-TYPE
|
|
SYNTAX Integer32 (-80..140)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This displays the internal temperature in 1 Celsius on the Net 2 SFP with SFF-8472 extensions"
|
|
::= { adTa5kSmSystemEntry 22 }
|
|
|
|
adTa5kSmNet2SFPSupplyVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This displays the supply voltage in 1 mV on the Net 2 SFP with SFF-8472 extensions"
|
|
::= { adTa5kSmSystemEntry 23 }
|
|
|
|
-- ======================================================================
|
|
-- Provisioning Menu Items
|
|
|
|
adTa5kSmProvTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdTa5kSmProvEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"..."
|
|
::= { adTa5kSmProv 1 }
|
|
|
|
adTa5kSmProvEntry OBJECT-TYPE
|
|
SYNTAX AdTa5kSmProvEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"..."
|
|
INDEX { adGenSlotInfoIndex }
|
|
::= { adTa5kSmProvTable 1 }
|
|
|
|
AdTa5kSmProvEntry ::=
|
|
SEQUENCE {
|
|
adTa5kSmNode Integer32,
|
|
adTa5kSmUplink Integer32,
|
|
adTa5kSmAggregation INTEGER,
|
|
adTa5kSmPrimaryClock INTEGER,
|
|
adTa5kSmSecondaryClock INTEGER,
|
|
adTa5kSmCurrentClock INTEGER,
|
|
adTa5kSmClockModeRevertive INTEGER,
|
|
adTa5kSmForceClockFailover INTEGER,
|
|
adTa5kSmNetworkName DisplayString,
|
|
adTa5kSmTopologyChangeCount Integer32,
|
|
adTa5kSmTopologyInstance Integer32,
|
|
adTa5kSmLoopASource Integer32,
|
|
adTa5kSmLoopBSource Integer32,
|
|
adTa5kSmExtAType INTEGER,
|
|
adTa5kSmExtBType INTEGER,
|
|
adTa5kSmUpstreamChaining INTEGER,
|
|
adTa5kSmDownstreamChaining INTEGER,
|
|
adTa5kSmFallbackClock INTEGER,
|
|
adTa5kSmExtAQuality INTEGER,
|
|
adTa5kSmExtBQuality INTEGER,
|
|
adTa5kSmExtAPreference Integer32,
|
|
adTa5kSmExtBPreference Integer32,
|
|
adTa5kSmUseHopCount INTEGER,
|
|
adTa5kSmIGMPInterfaceMode INTEGER,
|
|
adTa5kSmSTagTPID INTEGER,
|
|
adTa5kSmExtAPriority Integer32,
|
|
adTa5kSmExtBPriority Integer32,
|
|
adTa5kSmInternalSTag Integer32,
|
|
adTa5kSmBpRateAlarmSeverityLevel INTEGER
|
|
}
|
|
|
|
adTa5kSmNode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TA5000 node number. Valid set values are 1..n, where n is adTa5kSmMaxNodes.
|
|
adTa5kSmNode will return 0 if the node number has not been set."
|
|
::= { adTa5kSmProvEntry 1 }
|
|
|
|
adTa5kSmUplink OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"0 = None
|
|
1 - 22 = Slot number assignment
|
|
23 = Peer (Used by a special Facility Protect Mode, not used)
|
|
24 = Uplink is located on an expansion shelf
|
|
25 = Network port 1
|
|
26 = Network port 2
|
|
27 = Aggregation group
|
|
28 = Network port 3
|
|
29 = Network port 4
|
|
30 = ERPS ring 1
|
|
31 = ERPS ring 2
|
|
32 = ERPS ring 3
|
|
33 = ERPS ring 4"
|
|
::= { adTa5kSmProvEntry 2 }
|
|
|
|
adTa5kSmAggregation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2),
|
|
notApplicable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling this setting will allow both net1 and net2 to operate as a single link"
|
|
::= { adTa5kSmProvEntry 3 }
|
|
|
|
adTa5kSmPrimaryClock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
local (1),
|
|
net1 (2),
|
|
net2 (3),
|
|
loopA (4),
|
|
loopB (5),
|
|
extA (7),
|
|
extB (8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Select the primary timing source for the system"
|
|
::= { adTa5kSmProvEntry 4 }
|
|
|
|
adTa5kSmSecondaryClock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
local (1),
|
|
net1 (2),
|
|
net2 (3),
|
|
loopA (4),
|
|
loopB (5),
|
|
extA (7),
|
|
extB (8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Select the secondary timing source for the system"
|
|
::= { adTa5kSmProvEntry 5 }
|
|
|
|
adTa5kSmCurrentClock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
primary (1),
|
|
secondary (2),
|
|
fallback (3),
|
|
standby (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Read-Only: Displays which clock is currently in use by the system"
|
|
::= { adTa5kSmProvEntry 6 }
|
|
|
|
adTa5kSmClockModeRevertive OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Enabling this allows the clock to fail back to the primary should the primary source's
|
|
health return to normal. Disabled means the clock will remain on the secondary source after
|
|
a failover."
|
|
::= { adTa5kSmProvEntry 7 }
|
|
|
|
adTa5kSmForceClockFailover OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
failover (1),
|
|
notavailable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Writing a value to this will cause the clock source to failover, a get will always return 1"
|
|
::= { adTa5kSmProvEntry 8 }
|
|
|
|
adTa5kSmNetworkName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a string that can be bound to this topology."
|
|
::= { adTa5kSmProvEntry 10 }
|
|
|
|
adTa5kSmTopologyChangeCount OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the topology of the network changes this number will be incremented."
|
|
::= { adTa5kSmProvEntry 11 }
|
|
|
|
adTa5kSmTopologyInstance OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to index the Tlv table, each time this is called it
|
|
creates an instance for that viewer to read bulk data."
|
|
::= { adTa5kSmProvEntry 12 }
|
|
|
|
adTa5kSmLoopASource OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Designate which slot the LoopA Timing source will listen on."
|
|
::= { adTa5kSmProvEntry 13 }
|
|
|
|
adTa5kSmLoopBSource OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Designate which slot the LoopB Timing source will listen on."
|
|
::= { adTa5kSmProvEntry 14 }
|
|
|
|
adTa5kSmExtAType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bitsD4 (1),
|
|
bitsOD (2),
|
|
composite (3),
|
|
composite8kHz (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Select which type the External clock A input should expect."
|
|
::= { adTa5kSmProvEntry 15 }
|
|
|
|
adTa5kSmExtBType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bitsD4 (1),
|
|
bitsOD (2),
|
|
composite (3),
|
|
composite8kHz (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Select which type the External clock B input should expect."
|
|
::= { adTa5kSmProvEntry 16 }
|
|
|
|
adTa5kSmUpstreamChaining OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2),
|
|
notApplicable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Enable/Disable Net1 port for redundancy chaining protection.
|
|
adTa5kUpstreamChaining has been replaced by adTa5kSmPortMode
|
|
beginning with TA5000 System Release 4.0."
|
|
::= { adTa5kSmProvEntry 17 }
|
|
|
|
adTa5kSmDownstreamChaining OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2),
|
|
notApplicable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Enable/Disable Net2 port for redundancy chaining protection.
|
|
adTa5kDownstreamChaining has been replaced by adTa5kSmPortMode
|
|
beginning with TA5000 System Release 4.0."
|
|
::= { adTa5kSmProvEntry 18 }
|
|
|
|
adTa5kSmFallbackClock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
local (1),
|
|
net1 (2),
|
|
net2 (3),
|
|
loopA (4),
|
|
loopB (5),
|
|
none (6),
|
|
extA (7),
|
|
extB (8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Select the fallback timing source for the system"
|
|
::= { adTa5kSmProvEntry 19 }
|
|
|
|
adTa5kSmExtAQuality OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
stratum1 (1),
|
|
synchronized (2),
|
|
stratum2 (3),
|
|
transmitModeClock (4),
|
|
stratum3e (5),
|
|
stratum3 (6),
|
|
sonetClock (7),
|
|
stratum4or4e (8),
|
|
doNotUseForSync (15)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Select the quality for External Clock A."
|
|
::= {adTa5kSmProvEntry 20 }
|
|
|
|
adTa5kSmExtBQuality OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
stratum1 (1),
|
|
synchronized (2),
|
|
stratum2 (3),
|
|
transmitModeClock (4),
|
|
stratum3e (5),
|
|
stratum3 (6),
|
|
sonetClock (7),
|
|
stratum4or4e (8),
|
|
doNotUseForSync (15)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Select the quality for External Clock B."
|
|
::= {adTa5kSmProvEntry 21 }
|
|
|
|
adTa5kSmExtAPreference OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32)
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object has been replaced by adTa5kSmExtAPriority."
|
|
::= {adTa5kSmProvEntry 22 }
|
|
|
|
adTa5kSmExtBPreference OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32)
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object has been replaced by adTa5kSmExtBPriority."
|
|
::= {adTa5kSmProvEntry 23 }
|
|
|
|
adTa5kSmUseHopCount OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Enable or disable the hop count in SM timing messages."
|
|
::= {adTa5kSmProvEntry 24 }
|
|
|
|
adTa5kSmIGMPInterfaceMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
diable (1),
|
|
proxy (2),
|
|
snooping (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This item controls processing of IGMP packets."
|
|
::= { adTa5kSmProvEntry 25 }
|
|
|
|
|
|
adTa5kSmSTagTPID OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The S-Tag TPID. The value is intended to be displayed as a hexadecimal number."
|
|
::= { adTa5kSmProvEntry 26 }
|
|
|
|
adTa5kSmExtAPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Select the priority for External Clock A.
|
|
Set adTa5kSmExtAPriority to 0 to use the
|
|
node number as the priority. Override this
|
|
default behavior by setting a value from 1 to 255."
|
|
::= {adTa5kSmProvEntry 27 }
|
|
|
|
adTa5kSmExtBPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Select the priority for External Clock B.
|
|
Set adTa5kSmExtBPriority to 0 to use the
|
|
node number as the priority. Override this
|
|
default behavior by setting a value from 1 to 255."
|
|
::= {adTa5kSmProvEntry 28 }
|
|
|
|
adTa5kSmInternalSTag OBJECT-TYPE
|
|
SYNTAX Integer32 (2..4094)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"S-Tag returned for internal data/configuration traffic."
|
|
::= {adTa5kSmProvEntry 29 }
|
|
|
|
adTa5kSmBpRateAlarmSeverityLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alert(3),
|
|
minor(4),
|
|
major(5),
|
|
critical(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provision the severity level of BpRateFallback alarm."
|
|
::= {adTa5kSmProvEntry 30 }
|
|
|
|
|
|
adTa5kSmNetworkPortProvTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdTa5kSmNetworkPortProvEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"..."
|
|
::= { adTa5kSmProv 2 }
|
|
|
|
adTa5kSmNetworkPortProvEntry OBJECT-TYPE
|
|
SYNTAX AdTa5kSmNetworkPortProvEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is indexed by the ifIndex of each Switch Module faceplate port."
|
|
INDEX { ifIndex }
|
|
::= { adTa5kSmNetworkPortProvTable 1 }
|
|
|
|
AdTa5kSmNetworkPortProvEntry ::=
|
|
SEQUENCE {
|
|
adTa5kSmPortMode INTEGER,
|
|
adTa5kSmLACPMode INTEGER
|
|
}
|
|
|
|
adTa5kSmPortMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unused (1),
|
|
networkInterface (2),
|
|
uplink (3),
|
|
downlink (4),
|
|
erps (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This value determines the how this port affects SM redundancy decisions.
|
|
Unused (1) - this port is ignored in redundancy decisions. Use this setting
|
|
for ports that are not in use, or any port that does not need to be
|
|
considered in redundancy decisions.
|
|
Network Interface (2) - Set adTa5kSmRedundancyMode to 2 only in Node 1, Shelf 1.
|
|
Indicates that this port is connected to an upstream router or other
|
|
non-TA5000 networking equipment.
|
|
Uplink (3) - Indicates that this port is connected to an upstream TA5000 Node.
|
|
Downlink (4) - Indicates that this port is connected to a downstream TA5000 Node.
|
|
ERPS (5) - Indicates that this port participates in an ERPS ring, and thus
|
|
supports ERPS timing, but is ignored for redundancy decisions."
|
|
::= {adTa5kSmNetworkPortProvEntry 1}
|
|
|
|
adTa5kSmLACPMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
active (2),
|
|
passive (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"LACP Mode for the network port."
|
|
::= {adTa5kSmNetworkPortProvEntry 2}
|
|
|
|
adTa5kSmEthernetDefaultInterface OBJECT IDENTIFIER ::= { adTa5kSmProv 3 }
|
|
|
|
adTa5kSmEthDefaultInterfaceIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IfIndex of the ethernet default interface.
|
|
A value of zero indicates no ethernet default interface.
|
|
** Warning ** Setting adTa5kSmEthDefaultInterfaceIndex can
|
|
disable remote management of this system."
|
|
::= { adTa5kSmEthernetDefaultInterface 1 }
|
|
|
|
EthernetDefaultInterfaceType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the interface types which may be the ethernet default interface."
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
gigabitEthernet(2),
|
|
tenGigabitEthernet(3),
|
|
lagGroup(4),
|
|
accessModule(5),
|
|
efmGroup(6),
|
|
efmPort(7),
|
|
erps(8),
|
|
atmPort(9),
|
|
rpr(10),
|
|
atmGroup(11),
|
|
muxponderSlot(12),
|
|
xGigabitEthernet(13)
|
|
}
|
|
|
|
adTa5kSmEthernetDefaultIfcType OBJECT-TYPE
|
|
SYNTAX EthernetDefaultInterfaceType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ethernet default interface type."
|
|
::= {adTa5kSmEthernetDefaultInterface 2}
|
|
|
|
adTa5kSmEthernetDefaultIfcSlot OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ethernet default interface slot.
|
|
Slots 1-22 represent access module slots.
|
|
Slot 239 is the active SM slot.
|
|
Slot 252 is SM-A.
|
|
Slot 253 is SM-B.
|
|
adTa5kSmEthernetDefaultIfcSlot will return 0 if adTa5kSmEthernetDefaultIfcType = none(1)."
|
|
::= {adTa5kSmEthernetDefaultInterface 3}
|
|
|
|
adTa5kSmEthernetDefaultIfcPort OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ethernet default interface port. This value may represent a physical port
|
|
or a logical port. For example, if the ethernet default interface is
|
|
gigabit-ethernet 1/A/2, then adTa5kSmEthernetDefaultIfcPort = physical port 2.
|
|
If the ethernet default interface is lag-group 1/A/1, then
|
|
adTa5kSmEthernetDefaultIfcPort = 1 to indicate lag-group #1 on slot A.
|
|
adTa5kSmEthernetDefaultIfcPort will return 0 if adTa5kSmEthernetDefaultIfcType = none(1)."
|
|
|
|
::= {adTa5kSmEthernetDefaultInterface 4}
|
|
|
|
|
|
-- ******************************************************************************************
|
|
-- Alarm Provisioning
|
|
-- ******************************************************************************************
|
|
|
|
adTa5kSmAlarmProvTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdTa5kSmAlarmProvEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"..."
|
|
::= { adTa5kSmProv 4 }
|
|
|
|
adTa5kSmAlarmProvEntry OBJECT-TYPE
|
|
SYNTAX AdTa5kSmAlarmProvEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"..."
|
|
INDEX { adGenSlotInfoIndex }
|
|
::= { adTa5kSmAlarmProvTable 1 }
|
|
|
|
AdTa5kSmAlarmProvEntry ::=
|
|
SEQUENCE {
|
|
adTa5kSmRingGenFailAlarmEnable TruthValue,
|
|
adTa5kSmPowerLimitExceededAlarmEnable TruthValue,
|
|
adTa5kSmDuplicateNodeAlarmEnable TruthValue,
|
|
adTa5kSmDuplicateScmIpAlarmEnable TruthValue,
|
|
adTa5kSmNodeNumberProvAlarmEnable TruthValue,
|
|
adTa5kSmMgmtVlanFailAlarmEnable TruthValue,
|
|
adTa5kSmioMismatchAlarmEnable TruthValue,
|
|
adTa5kSmBPRateFallbackAlarmEnable TruthValue,
|
|
adTa5kSmPeerLinksDownAlarmEnable TruthValue
|
|
}
|
|
|
|
adTa5kSmRingGenFailAlarmEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"True - alarm is enabled"
|
|
|
|
DEFVAL {true}
|
|
|
|
::= { adTa5kSmAlarmProvEntry 1 }
|
|
|
|
adTa5kSmPowerLimitExceededAlarmEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"True - alarm is enabled"
|
|
|
|
DEFVAL {true}
|
|
|
|
::= { adTa5kSmAlarmProvEntry 2 }
|
|
|
|
adTa5kSmDuplicateNodeAlarmEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"True - alarm is enabled"
|
|
|
|
DEFVAL {true}
|
|
|
|
::= { adTa5kSmAlarmProvEntry 3 }
|
|
|
|
adTa5kSmDuplicateScmIpAlarmEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"True - alarm is enabled"
|
|
|
|
DEFVAL {true}
|
|
|
|
::= { adTa5kSmAlarmProvEntry 4 }
|
|
|
|
adTa5kSmNodeNumberProvAlarmEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"True - alarm is enabled"
|
|
|
|
DEFVAL {true}
|
|
|
|
::= { adTa5kSmAlarmProvEntry 5 }
|
|
|
|
adTa5kSmMgmtVlanFailAlarmEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"True - alarm is enabled"
|
|
|
|
DEFVAL {true}
|
|
|
|
::= { adTa5kSmAlarmProvEntry 6 }
|
|
|
|
adTa5kSmioMismatchAlarmEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"True - alarm is enabled"
|
|
|
|
DEFVAL {true}
|
|
|
|
::= { adTa5kSmAlarmProvEntry 7 }
|
|
|
|
adTa5kSmBPRateFallbackAlarmEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"True - alarm is enabled"
|
|
|
|
DEFVAL {true}
|
|
|
|
::= { adTa5kSmAlarmProvEntry 8 }
|
|
|
|
|
|
adTa5kSmPeerLinksDownAlarmEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"True - alarm is enabled"
|
|
|
|
DEFVAL {true}
|
|
|
|
::= { adTa5kSmAlarmProvEntry 9 }
|
|
|
|
-- ***************************************************************
|
|
-- Status Items
|
|
-- ***************************************************************
|
|
|
|
adTa5kSmClockStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdTa5kSmClockStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"..."
|
|
::= { adTa5kSmStatus 1 }
|
|
|
|
adTa5kSmClockStatusEntry OBJECT-TYPE
|
|
SYNTAX AdTa5kSmClockStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"..."
|
|
INDEX { adGenSlotInfoIndex }
|
|
::= { adTa5kSmClockStatusTable 1 }
|
|
|
|
AdTa5kSmClockStatusEntry ::=
|
|
SEQUENCE {
|
|
adTa5kSmLoopAClockHealth INTEGER,
|
|
adTa5kSmLoopBClockHealth INTEGER,
|
|
adTa5kSmBitsAClockHealth INTEGER,
|
|
adTa5kSmBitsBClockHealth INTEGER,
|
|
adTa5kSmPrimaryClockHealth INTEGER,
|
|
adTa5kSmSecondaryClockHealth INTEGER,
|
|
adTa5kSmRingVoltagePresent Integer32,
|
|
adTa5kSmRingFail Integer32,
|
|
adTa5kSmPeerRingFail Integer32,
|
|
adTa5kSmCurrentHopCount INTEGER,
|
|
adTa5kSmCurrentTimingSourcePriority INTEGER,
|
|
adTa5kSmCurrentTimingSourceQuality INTEGER
|
|
}
|
|
|
|
adTa5kSmLoopAClockHealth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up (1),
|
|
down (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Displays the health of the loop A timing source"
|
|
::= { adTa5kSmClockStatusEntry 1 }
|
|
|
|
adTa5kSmLoopBClockHealth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up (1),
|
|
down (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Displays the health of the loop B timing source"
|
|
::= { adTa5kSmClockStatusEntry 2 }
|
|
|
|
adTa5kSmBitsAClockHealth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up (1),
|
|
down (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Displays the health of the bits A timing source"
|
|
::= { adTa5kSmClockStatusEntry 3 }
|
|
|
|
adTa5kSmBitsBClockHealth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up (1),
|
|
down (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Displays the health of the bits B timing source"
|
|
::= { adTa5kSmClockStatusEntry 4 }
|
|
|
|
adTa5kSmPrimaryClockHealth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up (1),
|
|
down (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Displays the health of the primary timing source"
|
|
::= { adTa5kSmClockStatusEntry 5 }
|
|
|
|
adTa5kSmSecondaryClockHealth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up (1),
|
|
down (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Displays the health of the secondary timing source"
|
|
::= { adTa5kSmClockStatusEntry 6 }
|
|
|
|
adTa5kSmRingVoltagePresent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Boolean, 0 - Ring voltage is not present, 1 - Ring voltage is
|
|
present. If you are not using an internal ring generator then
|
|
this could indicate that the external ring voltage source has
|
|
failed or is not connected."
|
|
::= { adTa5kSmClockStatusEntry 7 }
|
|
|
|
adTa5kSmRingFail OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Boolean, 0 - Not Failed, 1 - Failed."
|
|
::= { adTa5kSmClockStatusEntry 8 }
|
|
|
|
adTa5kSmPeerRingFail OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Boolean, 0 - Not Failed, 1 - Failed."
|
|
::= { adTa5kSmClockStatusEntry 9 }
|
|
|
|
adTa5kSmCurrentHopCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The number of hops for the current timing source."
|
|
::= { adTa5kSmClockStatusEntry 10 }
|
|
|
|
adTa5kSmCurrentTimingSourcePriority OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The priority value for the current timing source."
|
|
::= { adTa5kSmClockStatusEntry 11 }
|
|
|
|
adTa5kSmCurrentTimingSourceQuality OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
stratum1 (1),
|
|
synchronized (2),
|
|
stratum2 (3),
|
|
transmitModeClock (4),
|
|
stratum3e (5),
|
|
stratum3 (6),
|
|
sonetClock (7),
|
|
stratum4or4e (8),
|
|
doNotUseForSync (15)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The quality of the current timing source."
|
|
::= { adTa5kSmClockStatusEntry 12 }
|
|
|
|
-- ***************************************************************
|
|
|
|
adTa5kSmMetalicTestAccessTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdTa5kSmMetalicTestAccessEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"..."
|
|
::= { adTa5kSmTest 1 }
|
|
|
|
adTa5kSmMetalicTestAccessEntry OBJECT-TYPE
|
|
SYNTAX AdTa5kSmMetalicTestAccessEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"..."
|
|
INDEX { adGenSlotInfoIndex }
|
|
::= { adTa5kSmMetalicTestAccessTable 1 }
|
|
|
|
AdTa5kSmMetalicTestAccessEntry ::=
|
|
SEQUENCE {
|
|
adTa5kSmFacilityTR INTEGER,
|
|
adTa5kSmFacilityT1R1 INTEGER,
|
|
adTa5kSmEquipmentTR INTEGER,
|
|
adTa5kSmEquipmentT1R1 INTEGER,
|
|
adTa5kSmLoopTR INTEGER,
|
|
adTa5kSmLoopT1R1 INTEGER
|
|
}
|
|
|
|
adTa5kSmFacilityTR OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2),
|
|
notApplicable (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { adTa5kSmMetalicTestAccessEntry 1 }
|
|
|
|
adTa5kSmFacilityT1R1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2),
|
|
notApplicable (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { adTa5kSmMetalicTestAccessEntry 2 }
|
|
|
|
adTa5kSmEquipmentTR OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2),
|
|
notApplicable (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { adTa5kSmMetalicTestAccessEntry 3 }
|
|
|
|
adTa5kSmEquipmentT1R1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2),
|
|
notApplicable (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { adTa5kSmMetalicTestAccessEntry 4 }
|
|
|
|
adTa5kSmLoopTR OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2),
|
|
notApplicable (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { adTa5kSmMetalicTestAccessEntry 5 }
|
|
|
|
adTa5kSmLoopT1R1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2),
|
|
notApplicable (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { adTa5kSmMetalicTestAccessEntry 6 }
|
|
|
|
|
|
-- ***************************************************************
|
|
|
|
adTa5kSmAtpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdTa5kSmAtpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"..."
|
|
::= { adTa5kSmAtpMfg 1 }
|
|
|
|
adTa5kSmAtpEntry OBJECT-TYPE
|
|
SYNTAX AdTa5kSmAtpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"..."
|
|
INDEX { adGenSlotInfoIndex }
|
|
::= { adTa5kSmAtpTable 1 }
|
|
|
|
AdTa5kSmAtpEntry ::=
|
|
SEQUENCE {
|
|
adTa5kSmTemp1 Integer32,
|
|
adTa5kSmTemp2 Integer32,
|
|
adTa5kSmExpMac OCTET STRING,
|
|
adTa5kSmPeerMac OCTET STRING
|
|
}
|
|
|
|
adTa5kSmTemp1 OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Upper Temp sensor: Temperature in tenths of a degrees C."
|
|
::= { adTa5kSmAtpEntry 1 }
|
|
|
|
adTa5kSmTemp2 OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Lower Temp sensor: Temperature in tenths of a degrees C."
|
|
::= { adTa5kSmAtpEntry 2 }
|
|
|
|
adTa5kSmExpMac OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mac Address of the Expansion Port."
|
|
::= { adTa5kSmAtpEntry 3 }
|
|
|
|
adTa5kSmPeerMac OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mac Address of the internal link between the SM and its peer."
|
|
::= { adTa5kSmAtpEntry 4 }
|
|
|
|
-- -------------------------------------
|
|
-- Switch Module Alarms
|
|
-- -------------------------------------
|
|
|
|
adTa5kSmTimingSrcClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Indicates that the primary and/or secondary timing source alarm has cleared"
|
|
|
|
--#TYPE "Status - Timing Src Alarm Clear"
|
|
--#SUMMARY "TA5000 Switch Module: Timing Source Cleared on"
|
|
--#SUMMARY "Shelf: %s"
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 2 }
|
|
|
|
adTa5kSmTimingSrcFail NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Indicates that the primary and/or secondary timing source has failed"
|
|
|
|
--#TYPE "Status - Timing Src Alarm Active"
|
|
--#SUMMARY "TA5000 Switch Module: Timing Source Failure on"
|
|
--#SUMMARY "Shelf: %s"
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 3 }
|
|
|
|
adTa5kSmRingGenClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates ring generator alarm clear"
|
|
|
|
--#TYPE "Status - Ring Generator Alarm Clear"
|
|
--#SUMMARY "TA5000 Switch Module: Ring Generator Alarm Cleared on"
|
|
--#SUMMARY "Shelf: %s"
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 4 }
|
|
|
|
adTa5kSmRingGenFail NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the ring generator has failed"
|
|
|
|
--#TYPE "Status - Ring Generator Alarm Active"
|
|
--#SUMMARY "TA5000 Switch Module: Ring Generator Failure on"
|
|
--#SUMMARY "Shelf: %s"
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 5 }
|
|
|
|
adTa5kSmPowerLimitAlmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the power limit alarm has cleared"
|
|
|
|
--#TYPE "Status - Power Limit Alarm Clear"
|
|
--#SUMMARY "TA5000 Switch Module: Power Limit Alarm Cleared on"
|
|
--#SUMMARY "Shelf: %s"
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY MAJOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 6 }
|
|
|
|
adTa5kSmPowerLimitExceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the shelf power limit has been exceeded"
|
|
|
|
--#TYPE "Status - Power Limit Alarm Active"
|
|
--#SUMMARY "TA5000 Switch Module: Power Limit Exceeded On"
|
|
--#SUMMARY "Shelf: %s"
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY MAJOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 7 }
|
|
|
|
adTa5kSmUnknownSfpClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
adGenPortTrapIdentifier
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the unknown SFP alarm has cleared"
|
|
|
|
--#TYPE "Status - Unknown SFP Alarm Clear"
|
|
--#SUMMARY "TA5000 Switch Module: Unknown SFP Alarm Cleared on"
|
|
--#SUMMARY "Shelf: %s Slot, Port: %s"
|
|
--#ARGUMENTS {1,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 8 }
|
|
|
|
adTa5kSmUnknownSfpAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
adGenPortTrapIdentifier
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the unknown SFP alarm is active"
|
|
|
|
--#TYPE "Status - Unknown SFP Alarm"
|
|
--#SUMMARY "TA5000 Switch Module: Unknown SFP Alarm on"
|
|
--#SUMMARY "Shelf: %s Slot, Port: %s"
|
|
--#ARGUMENTS {1,3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 9 }
|
|
|
|
adTa5kSmSfpFaultClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
adGenPortTrapIdentifier
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the SFP fault has cleared"
|
|
|
|
--#TYPE "Status - SFP Fault Clear"
|
|
--#SUMMARY "TA5000 Switch Module: SFP Fault Cleared on"
|
|
--#SUMMARY "Shelf: %s Slot, Port: %s"
|
|
--#ARGUMENTS {1,3}
|
|
--#SEVERITY MAJOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 10 }
|
|
|
|
adTa5kSmSfpFaultActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
adGenPortTrapIdentifier
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the SFP fault is active"
|
|
|
|
--#TYPE "Status - SFP Fault Active"
|
|
--#SUMMARY "TA5000 Switch Module: SFP Fault Active on"
|
|
--#SUMMARY "Shelf: %s Slot, Port: %s"
|
|
--#ARGUMENTS {1,3}
|
|
--#SEVERITY MAJOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 11 }
|
|
|
|
adTa5kSmMultipleUplinksClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Indicates that the multiple uplink alarm has cleared"
|
|
|
|
--#TYPE "Status - Multiple Uplink Alarm Clear"
|
|
--#SUMMARY "TA5000 Switch Module: Multiple Uplink Alarm Cleared on"
|
|
--#SUMMARY "Shelf: %s, Slot %d"
|
|
--#ARGUMENTS {1, 2}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 12 }
|
|
|
|
adTa5kSmMultipleUplinksDetected NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Indicates that multiple uplinks have been detected"
|
|
|
|
--#TYPE "Status - Multiple Uplink Alarm Active"
|
|
--#SUMMARY "TA5000 Switch Module: Multiple Uplink Alarm Active on"
|
|
--#SUMMARY "Shelf: %s, Slot %d"
|
|
--#ARGUMENTS {1, 2}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 13 }
|
|
|
|
adTa5kSmExtAFailureClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the ExtA timing failure has been cleared"
|
|
|
|
--#TYPE "Status - ExtA Timing Failure Clear"
|
|
--#SUMMARY "TA5000 Switch Module: ExtA Timing Failure Cleared On"
|
|
--#SUMMARY "Shelf: %s, Slot %d"
|
|
--#ARGUMENTS {1, 2}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 14 }
|
|
|
|
adTa5kSmExtAFailureActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the ExtA timing has failed"
|
|
|
|
--#TYPE "Status - ExtA Timing Failure Active"
|
|
--#SUMMARY "TA5000 Switch Module: ExtA Timing Failure Active On"
|
|
--#SUMMARY "Shelf: %s, Slot %d"
|
|
--#ARGUMENTS {1, 2}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 15 }
|
|
|
|
adTa5kSmExtBFailureClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the ExtB timing failure has been cleared"
|
|
|
|
--#TYPE "Status - ExtB Timing Failure Clear"
|
|
--#SUMMARY "TA5000 Switch Module: ExtB Timing Failure Cleared On"
|
|
--#SUMMARY "Shelf: %s, Slot %d"
|
|
--#ARGUMENTS {1, 2}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 16 }
|
|
|
|
adTa5kSmExtBFailureActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the ExtA timing has failed"
|
|
|
|
--#TYPE "Status - ExtB Timing Failure Active"
|
|
--#SUMMARY "TA5000 Switch Module: ExtB Timing Failure Active On"
|
|
--#SUMMARY "Shelf: %s, Slot %d"
|
|
--#ARGUMENTS {1, 2}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 17 }
|
|
|
|
adTa5kSmLossOfHeartbeatClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
adGenPortTrapIdentifier
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the loss of heartbeat alarm cleared"
|
|
|
|
--#TYPE "Status - Loss of Heartbeat Clear"
|
|
--#SUMMARY "TA5000 Switch Module: Loss of Heartbeat Alarm Cleared on"
|
|
--#SUMMARY "Shelf: %s Slot, Port: %s"
|
|
--#ARGUMENTS {1,3}
|
|
--#SEVERITY MAJOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 18 }
|
|
|
|
adTa5kSmLossOfHeartbeatActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
adGenPortTrapIdentifier
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the loss of heartbeat alarm is active"
|
|
|
|
--#TYPE "Status - Loss of Heartbeat Alarm Active"
|
|
--#SUMMARY "TA5000 Switch Module: Loss of Heartbeat Alarm Active on"
|
|
--#SUMMARY "Shelf: %s Slot, Port: %s"
|
|
--#ARGUMENTS {1,3}
|
|
--#SEVERITY MAJOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 19 }
|
|
|
|
adTa5kSmLossOfNetworkStpClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
adGenPortTrapIdentifier
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Indicates that the loss of network STP alarm cleared"
|
|
|
|
--#TYPE "Status - Loss of Network STP Clear"
|
|
--#SUMMARY "TA5000 Switch Module: Loss of Network STP Alarm Cleared on"
|
|
--#SUMMARY "Shelf: %s Slot, Port: %s"
|
|
--#ARGUMENTS {1,3}
|
|
--#SEVERITY MAJOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 20 }
|
|
|
|
adTa5kSmLossOfNetworkStpActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
adGenPortTrapIdentifier
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Indicates that the loss of network STP alarm active"
|
|
|
|
--#TYPE "Status - Loss of Network STP Active"
|
|
--#SUMMARY "TA5000 Switch Module: Loss of Network STP Alarm Active on"
|
|
--#SUMMARY "Shelf: %s Slot, Port: %s"
|
|
--#ARGUMENTS {1,3}
|
|
--#SEVERITY MAJOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 21 }
|
|
|
|
adTa5kSmDuplicateNodeClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
adTa5kSmNode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the duplicate node alarm has been cleared"
|
|
|
|
--#TYPE "Status - Duplicate Node Alarm Clear"
|
|
--#SUMMARY "TA5000 Switch Module: Duplicate Node Alarm Cleared On"
|
|
--#SUMMARY "Shelf: %s, Slot %d, Node %d"
|
|
--#ARGUMENTS {1, 2, 3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 22 }
|
|
|
|
adTa5kSmDuplicateNodeActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
adTa5kSmNode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the duplicate node alarm is active"
|
|
|
|
--#TYPE "Status - Duplicate Node Alarm Clear"
|
|
--#SUMMARY "TA5000 Switch Module: Duplicate Node Alarm Active on"
|
|
--#SUMMARY "Shelf: %s, Slot %d, Node %d"
|
|
--#ARGUMENTS {1, 2, 3}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 23 }
|
|
|
|
adTa5kSmDuplicateScmIpClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the duplicate SCM IP address alarm has been cleared"
|
|
|
|
--#TYPE "Status - Duplicate SCM IP Address Alarm Clear"
|
|
--#SUMMARY "TA5000 Switch Module: Duplicate SCM IP Address Alarm Cleared On"
|
|
--#SUMMARY "Shelf: %s, Slot %d"
|
|
--#ARGUMENTS {1, 2}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 24 }
|
|
|
|
adTa5kSmDuplicateScmIpActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the duplicate SCM IP address alarm is active"
|
|
|
|
--#TYPE "Status - Duplicate SCM IP Address Alarm Active"
|
|
--#SUMMARY "TA5000 Switch Module: Duplicate SCM IP Address Alarm on"
|
|
--#SUMMARY "Shelf: %s, Slot %d"
|
|
--#ARGUMENTS {1, 2}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 25 }
|
|
|
|
adTa5kSmBandwidthFullClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
adGenPortTrapIdentifier
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the Bandwidth full alarm has been cleared"
|
|
|
|
--#TYPE "Status - Bandwidth Full Alarm Clear"
|
|
--#SUMMARY "TA5000 Switch Module: Bandwidth Full Alarm Cleared On"
|
|
--#SUMMARY "Shelf: %s, Slot, Node: %s"
|
|
--#ARGUMENTS {1, 3}
|
|
--#SEVERITY MAJOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 26 }
|
|
|
|
adTa5kSmBandwidthFull NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
adGenPortTrapIdentifier
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the Bandwidth full alarm is active"
|
|
|
|
--#TYPE "Status - Bandwidth Full Alarm"
|
|
--#SUMMARY "TA5000 Switch Module: Bandwidth Full Alarm Active On"
|
|
--#SUMMARY "Shelf: %s, Slot, Node: %s"
|
|
--#ARGUMENTS {1, 3}
|
|
--#SEVERITY MAJOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 27 }
|
|
|
|
adTa5kSmPriTimingSrcClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Indicates that the primary timing source alarm has cleared"
|
|
|
|
--#TYPE "Status - Primary Timing Src Alarm Clear"
|
|
--#SUMMARY "TA5000 Switch Module: Timing Source Cleared on"
|
|
--#SUMMARY "Shelf: %s"
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 28 }
|
|
|
|
adTa5kSmPriTimingSrcFail NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Indicates that the primary timing source has failed"
|
|
|
|
--#TYPE "Status - Primary Timing Src Alarm Active"
|
|
--#SUMMARY "TA5000 Switch Module: Timing Source Failure on"
|
|
--#SUMMARY "Shelf: %s"
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 29 }
|
|
|
|
adTa5kSmSecTimingSrcClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Indicates that the secondary timing source alarm has cleared"
|
|
|
|
--#TYPE "Status - Secondary Timing Src Alarm Clear"
|
|
--#SUMMARY "TA5000 Switch Module: Timing Source Cleared on"
|
|
--#SUMMARY "Shelf: %s"
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 30 }
|
|
|
|
adTa5kSmSecTimingSrcFail NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Indicates that the secondary timing source has failed"
|
|
|
|
--#TYPE "Status - Secondary Timing Src Alarm Active"
|
|
--#SUMMARY "TA5000 Switch Module: Timing Source Failure on"
|
|
--#SUMMARY "Shelf: %s"
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 31 }
|
|
|
|
adTa5kSmNodeNumberProvClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the shelf's node number has been provisioned and is not zero."
|
|
|
|
--#TYPE "Status - SM Node Number Alarm Clear"
|
|
--#SUMMARY "TA5000 Switch Module: Node Number Alarm Cleared on"
|
|
--#SUMMARY "Shelf: %s"
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY WARNING
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 32 }
|
|
|
|
adTa5kSmNodeNumberDefault NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the shelf's node number has not been provisioned."
|
|
|
|
--#TYPE "Status - SM Node Number Alarm"
|
|
--#SUMMARY "TA5000 Switch Module: Node Number Alarm on"
|
|
--#SUMMARY "Shelf: %s"
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY WARNING
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 33 }
|
|
|
|
adTa5kSmMgmtVlanFailClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the SM's failure to communicate the Internal Management VLAN to an access module has cleared."
|
|
|
|
--#TYPE "Status - Internal Mgmt VLAN Alarm Clear"
|
|
--#SUMMARY "TA5000 Switch Module: Internal Mgmt VLAN Alarm Cleared on"
|
|
--#SUMMARY "Shelf: %s, Slot: %d"
|
|
--#ARGUMENTS {1, 2}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 34 }
|
|
|
|
adTa5kSmMgmtVlanFail NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the SM has failed to communicate the Internal Management VLAN to an access module."
|
|
|
|
--#TYPE "Status - Internal Mgmt VLAN Alarm"
|
|
--#SUMMARY "TA5000 Switch Module: Internal Mgmt VLAN Alarm on"
|
|
--#SUMMARY "Shelf: %s, Slot: %d"
|
|
--#ARGUMENTS {1, 2}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 35 }
|
|
|
|
adTa5kSmioMismatchClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that either there is no hardware incompatibility among the SM cards
|
|
and SMIO Or ERPS/CSLAG is not provisioned."
|
|
|
|
--#TYPE "Status - incompatible SMIO alarm cleared"
|
|
--#SUMMARY "TA5000 Switch Module: no hardware incompatibility among the SM and SMIO Or ERPS/CSLAG is not provisioned."
|
|
--#SUMMARY "Shelf: %s, Slot %d"
|
|
--#ARGUMENTS {1, 2}
|
|
--#SEVERITY MAJOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 36 }
|
|
|
|
adTa5kSmioMismatch NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that attempts for provisioning of ERPS or CSLAG is made and hardware incompatibility detected
|
|
among SM and SMIO"
|
|
|
|
--#TYPE "Status - incompatible SMIO"
|
|
--#SUMMARY "TA5000 Switch Module: Attempts for provisioning of ERPS or CSLAG is made and hardware incompatibility detected among SM and SMIO"
|
|
--#SUMMARY "Shelf: %s, Slot %d"
|
|
--#ARGUMENTS {1, 2}
|
|
--#SEVERITY MAJOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 37 }
|
|
|
|
adTa5kSmBackPlaneRateFallbackClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex,
|
|
adTAeSCUTrapAlarmLevel
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the AM is out of Backplane Rate Fallback mode.
|
|
adGenSlotInfoIndex indicates the slot of the card sending the alarm,
|
|
which is always the active SM.
|
|
ifIndex indicates the associated backplane port interface at
|
|
fault."
|
|
|
|
--#TYPE "Status - BackPlane Rate Fallback Alarm Active"
|
|
--#SUMMARY "TA5000 Switch Module: BackPlane Rate Fallback Alarm on"
|
|
--#SUMMARY "Shelf: %s, Slot: %d, Port: %d"
|
|
--#ARGUMENTS {1, 2, 3}
|
|
--#SEVERITY ALERT
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 38 }
|
|
|
|
adTa5kSmBackPlaneRateFallback NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex,
|
|
adTAeSCUTrapAlarmLevel
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the AM is in Backplane Rate Fallback mode.
|
|
adGenSlotInfoIndex indicates the slot of the card sending the alarm,
|
|
which is always the active SM.
|
|
ifIndex indicates the associated backplane port interface at
|
|
fault."
|
|
|
|
--#TYPE "Status - BackPlane Rate Fallback Alarm Active"
|
|
--#SUMMARY "TA5000 Switch Module: BackPlane Rate Fallback Alarm on"
|
|
--#SUMMARY "Shelf: %s, Slot: %d, Port: %d"
|
|
--#ARGUMENTS {1, 2, 3}
|
|
--#SEVERITY ALERT
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 39 }
|
|
|
|
adTa5kSmPeerLinkDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex,
|
|
ifDescr
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the link status of the high speed peer interface between redundant switch modules is up.
|
|
ifIndex indicates the associated peer port interface"
|
|
|
|
--#TYPE "Status - peer link down alarm cleared"
|
|
--#SUMMARY "TA5000 Switch Module: Peer Link Down Alarm cleared"
|
|
--#SUMMARY "Shelf: %s, Slot: %d, Port: %d"
|
|
--#ARGUMENTS {1, 2, 3}
|
|
--#SEVERITY MAJOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 40 }
|
|
|
|
adTa5kSmPeerLinkDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex,
|
|
ifIndex,
|
|
ifDescr
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the link status of the high speed peer interface between redundant switch modules is down.
|
|
ifIndex indicates the associated peer port interface"
|
|
|
|
--#TYPE "Status - peer link down alarm Active"
|
|
--#SUMMARY "TA5000 Switch Module: Peer Link Down Alarm on"
|
|
--#SUMMARY "Shelf: %s, Slot: %d, Port: %d"
|
|
--#ARGUMENTS {1, 2, 3}
|
|
--#SEVERITY MAJOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 41 }
|
|
|
|
adTa5kSmBackPlaneIncompatibleClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the Backplane Incompatible alarm has been cleared."
|
|
|
|
--#TYPE "Status - Backplane Incompatible alarm cleared"
|
|
--#SUMMARY "TA5000 Switch Module: Slot Backplane Incompatible alarm cleared."
|
|
--#SUMMARY "Shelf: %s, Slot: %d, "
|
|
--#ARGUMENTS {1, 2}
|
|
--#SEVERITY Major
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 42 }
|
|
|
|
|
|
|
|
adTa5kSmBackPlaneIncompatibleActive NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that SM cards are not capable of full backplane speeds to some slots in the chassis."
|
|
|
|
--#TYPE "Status - Backplane Incompatible alarm is active"
|
|
--#SUMMARY "TA5000 Switch Module: not capable of full backplane speeds to some slots in the chassis."
|
|
--#SUMMARY "Shelf: %s, Slot: %d, "
|
|
--#ARGUMENTS {1, 2}
|
|
--#SEVERITY Major
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adTa5kSmAlarms 43 }
|
|
|
|
|
|
END
|