ADTRAN-TA5K-SM-MIB DEFINITIONS ::= BEGIN -- TITLE: The ADTRAN Total Access TA5000 SM MIB -- PRODUCT: 1187020L1 -- VERSION: 1.0 -- DATE: Dec 12, 2006 -- This MIB Contains tables specific to the TA5000 SM -- -- MIBs supported: -- HISTORY: -- 05/08/18 tpm First edition: Node, SFP Data, Forwarding Control, Aggregation, -- Clocks, Metalic Test access -- 09/27/06 aed Changed adTa5kSmCurrentClock from read-write to read-only. -- 12/12/06 aed Added SM alarm definitions -- 02/01/07 aed Added adTa5KSmFallbackClock. Added two new enum values for adTa5kSmCurrentClock. -- 05/18/07 aed Added external clock quality and preference. -- 08/31/07 aed Import sysName from SNMPv2-SMI, not RFC 1213. -- 10/31/07 mguo changed "disable" from "0" to "1" on auto-negotiation. -- 11/05/07 aed Add support for IGMP interface mode and S-Tag TPID. -- Also, sysName should be imported from SNMPv2-MIB, not SNMPv2-SMI. -- 11/19/07 aed Add SNMP support for new timing status items: hop count, quality, and priority. -- Deprecated ExtA & ExtB preference provisioning items, because the range should be 0..255. -- 12/13/07 mguo Add support for SFP internal information on NET1 and NET2. -- 12/14/07 mguo Modified description of SFP TX/RX power levels from 0.1 dBm to 1 dBm. -- 02/27/07 aed Deprecate the exisiting timing failure alarm and add two new alarms for primary -- and secondary timing source failures. -- 05/13/08 aed Add two new alarm notifications: node number defaulted to 0, and internal mgmt vlan bad. -- 05/16/08 aed Modify the severity definitions for 5 alarms to match the SCM's alarm log severity. -- 06/10/08 aed Add support for port mode and lacp mode. Correct typos in some description fields. -- Deprecate adTa5kUpstreamChaining and adTa5kDownstreamChaining. -- 09/29/08 aed Changes for SR4.1. Maximum number of nodes is now 64. Modify the description of adTa5kSmUplink -- to include information for new SMs that have more than two faceplate ports. -- 10/31/08 aed Deprecate Loss of Network STP alarm and Multiple Uplinks alarm. -- 06/30/09 aed Deprecate SM-specific OIDs which have been replaced by new generic MIBs: -- 1) Deprecate the OIDs related to SFPs, in favor of adGenPluggablePort.mi2 -- 2) Deprecate autonegotiation OIDS in favor of genEthIfc.mi2 -- 3) Deprecate SystemTiming OIDs in favor of adGenSystemTiming.mi2 -- 09/30/09 aed Deprecate system timing alarms. These alarms have been moved to adGenSystemTiming.mi2 -- 11/09/09 jmz Documented additional uplink values added in SR5.0.2 -- 01/29/09 jmz Documented additional port mode values added in SR5.0.2 -- 2011/02/02 aed Deprecated adTa5kSmPortMode. (It has been moved to adTa5kTreeNetworking.mi2) -- Deprecated adTa5kSmLacpMode. (It has been moved to adTa5kLinkAggregation.mi2) -- Added OIDS for provisioning the ethernet default interface. -- Deprecate adTa5kSmUplink in favor of the ethernet default interface OIDs. -- *** DO NOT ADD REVISION COMMENTS HERE **** IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32, IpAddress, -- Gauge32, -- Counter64, -- TimeTicks, -- Unsigned32, NOTIFICATION-TYPE FROM SNMPv2-SMI sysName FROM SNMPv2-MIB ifIndex, ifDescr, InterfaceIndexOrZero -- InterfaceIndex FROM IF-MIB DisplayString, TruthValue, RowStatus, -- TimeInterval, MacAddress, TEXTUAL-CONVENTION FROM SNMPv2-TC -- SnmpAdminString -- FROM SNMP-FRAMEWORK-MIB adIdentity, adProducts, adMgmt FROM ADTRAN-MIB -- IANAifType -- FROM IANAifType-MIB adTrapInformSeqNum FROM ADTRAN-GENTRAPINFORM-MIB adGenSlotInfoIndex FROM ADTRAN-GENSLOT-MIB adGenPortTrapIdentifier FROM ADTRAN-GENPORT-MIB adTAeSCUTrapAlarmLevel FROM ADTRAN-TAeSCUEXT1-MIB; -- ********************************************************************************************************* adTa5kSmModuleIdentity MODULE-IDENTITY LAST-UPDATED "202110260000Z" ORGANIZATION "ADTRAN, Inc." CONTACT-INFO "CND Tech Support Postal: ADTRAN, Inc. 901 Explorer Blvd. Huntsville, AL 35806 Tel: +1 800 726-8663 Fax: +1 256 963 6217 E-mail: support@adtran.com" DESCRIPTION "Total Access 5000 SwitchModule 1187020L1 MIB" REVISION "202110260000Z" DESCRIPTION "Add support for Backplane Incompatible alarm." REVISION "201905070000Z" DESCRIPTION "Update TC for EthernetDefaultInterfaceType to include xGigabitEthernet." REVISION "201708241050Z" DESCRIPTION "Add support for SM's peer link down alarm." REVISION "201410291100Z" DESCRIPTION "Add support for the BpRateFallback alarm enables." REVISION "201409171555Z" DESCRIPTION "Add support for the new muxponderSlot type of Ethernet Default Interface." REVISION "201404241000Z" DESCRIPTION "Add support for the SM and SMIO hardware mismatch alarms." REVISION "201110261100Z" DESCRIPTION "Add support for the alarm enables." REVISION "201110111400Z" DESCRIPTION "Add support for the internal-system-s-tag" REVISION "201104122107Z" DESCRIPTION "Add the node number as a varbind for adTa5kSmDuplicateNodeClear and adTa5kSmDuplicateNodeActive." ::= { adIdentity 750 } -- OBJECT IDENTIFIERS adTa5kSm OBJECT IDENTIFIER ::= { adMgmt 750 } adTa5kSmTraps OBJECT IDENTIFIER ::= { adProducts 750 } adTa5kSmAlarms OBJECT IDENTIFIER ::= { adTa5kSmTraps 0 } adTa5kSmConfig OBJECT IDENTIFIER ::= { adTa5kSm 1 } adTa5kSmProv OBJECT IDENTIFIER ::= { adTa5kSm 2 } adTa5kSmStatus OBJECT IDENTIFIER ::= { adTa5kSm 3 } adTa5kSmTest OBJECT IDENTIFIER ::= { adTa5kSm 4 } adTa5kSmPerfMon OBJECT IDENTIFIER ::= { adTa5kSm 5 } adTa5kSmAtpMfg OBJECT IDENTIFIER ::= { adTa5kSm 6 } -- ====================================================================== -- Config Menu Items adTa5kSmSystemTable OBJECT-TYPE SYNTAX SEQUENCE OF AdTa5kSmSystemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "..." ::= { adTa5kSmConfig 1 } adTa5kSmSystemEntry OBJECT-TYPE SYNTAX AdTa5kSmSystemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "..." INDEX { adGenSlotInfoIndex } ::= { adTa5kSmSystemTable 1 } AdTa5kSmSystemEntry ::= SEQUENCE { adTa5kSmMaxNodes Integer32, adTa5kSmMaxShelves Integer32, adTa5kSmBootRev DisplayString, adTa5kSmNet1SFPDescription DisplayString, adTa5kSmNet2SFPDescription DisplayString, adTa5kSmRingGenType INTEGER, adTa5kSmSMIOType Integer32, adTa5kSmNet1AutoNegoAdmnStat INTEGER, adTa5kSmNet2AutoNegoAdmnStat INTEGER, adTa5kSmNet1SFPVendorPartNumber DisplayString, adTa5kSmNet1SFPVendorSerialNumber DisplayString, adTa5kSmNet1SFPRxPowerLevel Integer32, adTa5kSmNet1SFPTxPowerLevel Integer32, adTa5kSmNet1SFPTxBias Integer32, adTa5kSmNet1SFPTemperature Integer32, adTa5kSmNet1SFPSupplyVoltage Integer32, adTa5kSmNet2SFPVendorPartNumber DisplayString, adTa5kSmNet2SFPVendorSerialNumber DisplayString, adTa5kSmNet2SFPRxPowerLevel Integer32, adTa5kSmNet2SFPTxPowerLevel Integer32, adTa5kSmNet2SFPTxBias Integer32, adTa5kSmNet2SFPTemperature Integer32, adTa5kSmNet2SFPSupplyVoltage Integer32 } adTa5kSmMaxNodes OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The max number of nodes supported in a topology of TA5000's. Value returned is only valid at the COT." ::= { adTa5kSmSystemEntry 1 } adTa5kSmMaxShelves OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-only STATUS current DESCRIPTION "The max number of expansion shelves supported. Value returned is only valid at the COT." ::= { adTa5kSmSystemEntry 2 } adTa5kSmBootRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Displays the boot revision" ::= { adTa5kSmSystemEntry 3 } adTa5kSmNet1SFPDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (1..32)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This displays the description stored in the Net 1 SFP internal ROM." ::= { adTa5kSmSystemEntry 4 } adTa5kSmNet2SFPDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (1..32)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This displays the description stored in the Net 2 SFP internal ROM" ::= { adTa5kSmSystemEntry 5 } adTa5kSmRingGenType OBJECT-TYPE SYNTAX INTEGER { internal40REN (1), external (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of ring generator that is used to produce ringing on pots and combo cards." ::= { adTa5kSmSystemEntry 6 } adTa5kSmSMIOType OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The type of backplane interface that connects the Redundant SMs and optionally the SCM." ::= { adTa5kSmSystemEntry 7 } adTa5kSmNet1AutoNegoAdmnStat OBJECT-TYPE SYNTAX INTEGER { enable (1), disable(2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This is enablement and disablement of auto negotiation of the Net1 PHY" ::= { adTa5kSmSystemEntry 8 } adTa5kSmNet2AutoNegoAdmnStat OBJECT-TYPE SYNTAX INTEGER { enable (1), disable(2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This is enablement and disablement of auto negotiation of the Net2 PHY" ::= { adTa5kSmSystemEntry 9 } adTa5kSmNet1SFPVendorPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This displays the part-number stored in the Net 1 SFP internal ROM" ::= { adTa5kSmSystemEntry 10 } adTa5kSmNet1SFPVendorSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (1..32)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This displays the serial number stored in the Net 1 SFP internal ROM" ::= { adTa5kSmSystemEntry 11 } adTa5kSmNet1SFPRxPowerLevel OBJECT-TYPE SYNTAX Integer32 (-7000..7000) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This displays transceiver RX power level in 1 dBm on the Net 1 SFP with SFF-8472 extensions" ::= { adTa5kSmSystemEntry 12 } adTa5kSmNet1SFPTxPowerLevel OBJECT-TYPE SYNTAX Integer32 (-7000..7000) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This displays transceiver TX power level in 1 dBm on the Net 1 SFP with SFF-8472 extensions" ::= { adTa5kSmSystemEntry 13 } adTa5kSmNet1SFPTxBias OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This displays transceiver TX bias in 1 mA on the Net 1 SFP with SFF-8472 extensions" ::= { adTa5kSmSystemEntry 14 } adTa5kSmNet1SFPTemperature OBJECT-TYPE SYNTAX Integer32 (-80..140) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This displays the internal temperature in 1 Celsius on the Net 1 SFP with SFF-8472 extensions" ::= { adTa5kSmSystemEntry 15 } adTa5kSmNet1SFPSupplyVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This displays the supply voltage in 1 mV on the Net 1 SFP with SFF-8472 extensions" ::= { adTa5kSmSystemEntry 16 } adTa5kSmNet2SFPVendorPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (1..32)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This displays the vendor part-number stored in the Net 2 SFP internal ROM" ::= { adTa5kSmSystemEntry 17 } adTa5kSmNet2SFPVendorSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (1..32)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This displays the vendor serial number stored in the Net 2 SFP internal ROM" ::= { adTa5kSmSystemEntry 18 } adTa5kSmNet2SFPRxPowerLevel OBJECT-TYPE SYNTAX Integer32 (-7000..7000) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This displays transceiver RX power level in 1 dBm on the Net 2 SFP with SFF-8472 extensions" ::= { adTa5kSmSystemEntry 19 } adTa5kSmNet2SFPTxPowerLevel OBJECT-TYPE SYNTAX Integer32 (-7000..7000) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This displays transceiver TX power level in 1 dBm on the Net 2 SFP with SFF-8472 extensions" ::= { adTa5kSmSystemEntry 20 } adTa5kSmNet2SFPTxBias OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This displays transceiver TX bias in 1 mA on the Net 2 SFP with SFF-8472 extensions" ::= { adTa5kSmSystemEntry 21 } adTa5kSmNet2SFPTemperature OBJECT-TYPE SYNTAX Integer32 (-80..140) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This displays the internal temperature in 1 Celsius on the Net 2 SFP with SFF-8472 extensions" ::= { adTa5kSmSystemEntry 22 } adTa5kSmNet2SFPSupplyVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This displays the supply voltage in 1 mV on the Net 2 SFP with SFF-8472 extensions" ::= { adTa5kSmSystemEntry 23 } -- ====================================================================== -- Provisioning Menu Items adTa5kSmProvTable OBJECT-TYPE SYNTAX SEQUENCE OF AdTa5kSmProvEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "..." ::= { adTa5kSmProv 1 } adTa5kSmProvEntry OBJECT-TYPE SYNTAX AdTa5kSmProvEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "..." INDEX { adGenSlotInfoIndex } ::= { adTa5kSmProvTable 1 } AdTa5kSmProvEntry ::= SEQUENCE { adTa5kSmNode Integer32, adTa5kSmUplink Integer32, adTa5kSmAggregation INTEGER, adTa5kSmPrimaryClock INTEGER, adTa5kSmSecondaryClock INTEGER, adTa5kSmCurrentClock INTEGER, adTa5kSmClockModeRevertive INTEGER, adTa5kSmForceClockFailover INTEGER, adTa5kSmNetworkName DisplayString, adTa5kSmTopologyChangeCount Integer32, adTa5kSmTopologyInstance Integer32, adTa5kSmLoopASource Integer32, adTa5kSmLoopBSource Integer32, adTa5kSmExtAType INTEGER, adTa5kSmExtBType INTEGER, adTa5kSmUpstreamChaining INTEGER, adTa5kSmDownstreamChaining INTEGER, adTa5kSmFallbackClock INTEGER, adTa5kSmExtAQuality INTEGER, adTa5kSmExtBQuality INTEGER, adTa5kSmExtAPreference Integer32, adTa5kSmExtBPreference Integer32, adTa5kSmUseHopCount INTEGER, adTa5kSmIGMPInterfaceMode INTEGER, adTa5kSmSTagTPID INTEGER, adTa5kSmExtAPriority Integer32, adTa5kSmExtBPriority Integer32, adTa5kSmInternalSTag Integer32, adTa5kSmBpRateAlarmSeverityLevel INTEGER } adTa5kSmNode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The TA5000 node number. Valid set values are 1..n, where n is adTa5kSmMaxNodes. adTa5kSmNode will return 0 if the node number has not been set." ::= { adTa5kSmProvEntry 1 } adTa5kSmUplink OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS deprecated DESCRIPTION "0 = None 1 - 22 = Slot number assignment 23 = Peer (Used by a special Facility Protect Mode, not used) 24 = Uplink is located on an expansion shelf 25 = Network port 1 26 = Network port 2 27 = Aggregation group 28 = Network port 3 29 = Network port 4 30 = ERPS ring 1 31 = ERPS ring 2 32 = ERPS ring 3 33 = ERPS ring 4" ::= { adTa5kSmProvEntry 2 } adTa5kSmAggregation OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2), notApplicable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enabling this setting will allow both net1 and net2 to operate as a single link" ::= { adTa5kSmProvEntry 3 } adTa5kSmPrimaryClock OBJECT-TYPE SYNTAX INTEGER { local (1), net1 (2), net2 (3), loopA (4), loopB (5), extA (7), extB (8) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Select the primary timing source for the system" ::= { adTa5kSmProvEntry 4 } adTa5kSmSecondaryClock OBJECT-TYPE SYNTAX INTEGER { local (1), net1 (2), net2 (3), loopA (4), loopB (5), extA (7), extB (8) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Select the secondary timing source for the system" ::= { adTa5kSmProvEntry 5 } adTa5kSmCurrentClock OBJECT-TYPE SYNTAX INTEGER { primary (1), secondary (2), fallback (3), standby (4) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Read-Only: Displays which clock is currently in use by the system" ::= { adTa5kSmProvEntry 6 } adTa5kSmClockModeRevertive OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Enabling this allows the clock to fail back to the primary should the primary source's health return to normal. Disabled means the clock will remain on the secondary source after a failover." ::= { adTa5kSmProvEntry 7 } adTa5kSmForceClockFailover OBJECT-TYPE SYNTAX INTEGER { failover (1), notavailable (2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Writing a value to this will cause the clock source to failover, a get will always return 1" ::= { adTa5kSmProvEntry 8 } adTa5kSmNetworkName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a string that can be bound to this topology." ::= { adTa5kSmProvEntry 10 } adTa5kSmTopologyChangeCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "If the topology of the network changes this number will be incremented." ::= { adTa5kSmProvEntry 11 } adTa5kSmTopologyInstance OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to index the Tlv table, each time this is called it creates an instance for that viewer to read bulk data." ::= { adTa5kSmProvEntry 12 } adTa5kSmLoopASource OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Designate which slot the LoopA Timing source will listen on." ::= { adTa5kSmProvEntry 13 } adTa5kSmLoopBSource OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Designate which slot the LoopB Timing source will listen on." ::= { adTa5kSmProvEntry 14 } adTa5kSmExtAType OBJECT-TYPE SYNTAX INTEGER { bitsD4 (1), bitsOD (2), composite (3), composite8kHz (4) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Select which type the External clock A input should expect." ::= { adTa5kSmProvEntry 15 } adTa5kSmExtBType OBJECT-TYPE SYNTAX INTEGER { bitsD4 (1), bitsOD (2), composite (3), composite8kHz (4) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Select which type the External clock B input should expect." ::= { adTa5kSmProvEntry 16 } adTa5kSmUpstreamChaining OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2), notApplicable (3) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Enable/Disable Net1 port for redundancy chaining protection. adTa5kUpstreamChaining has been replaced by adTa5kSmPortMode beginning with TA5000 System Release 4.0." ::= { adTa5kSmProvEntry 17 } adTa5kSmDownstreamChaining OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2), notApplicable (3) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Enable/Disable Net2 port for redundancy chaining protection. adTa5kDownstreamChaining has been replaced by adTa5kSmPortMode beginning with TA5000 System Release 4.0." ::= { adTa5kSmProvEntry 18 } adTa5kSmFallbackClock OBJECT-TYPE SYNTAX INTEGER { local (1), net1 (2), net2 (3), loopA (4), loopB (5), none (6), extA (7), extB (8) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Select the fallback timing source for the system" ::= { adTa5kSmProvEntry 19 } adTa5kSmExtAQuality OBJECT-TYPE SYNTAX INTEGER { stratum1 (1), synchronized (2), stratum2 (3), transmitModeClock (4), stratum3e (5), stratum3 (6), sonetClock (7), stratum4or4e (8), doNotUseForSync (15) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Select the quality for External Clock A." ::= {adTa5kSmProvEntry 20 } adTa5kSmExtBQuality OBJECT-TYPE SYNTAX INTEGER { stratum1 (1), synchronized (2), stratum2 (3), transmitModeClock (4), stratum3e (5), stratum3 (6), sonetClock (7), stratum4or4e (8), doNotUseForSync (15) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Select the quality for External Clock B." ::= {adTa5kSmProvEntry 21 } adTa5kSmExtAPreference OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object has been replaced by adTa5kSmExtAPriority." ::= {adTa5kSmProvEntry 22 } adTa5kSmExtBPreference OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object has been replaced by adTa5kSmExtBPriority." ::= {adTa5kSmProvEntry 23 } adTa5kSmUseHopCount OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Enable or disable the hop count in SM timing messages." ::= {adTa5kSmProvEntry 24 } adTa5kSmIGMPInterfaceMode OBJECT-TYPE SYNTAX INTEGER { diable (1), proxy (2), snooping (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This item controls processing of IGMP packets." ::= { adTa5kSmProvEntry 25 } adTa5kSmSTagTPID OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The S-Tag TPID. The value is intended to be displayed as a hexadecimal number." ::= { adTa5kSmProvEntry 26 } adTa5kSmExtAPriority OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Select the priority for External Clock A. Set adTa5kSmExtAPriority to 0 to use the node number as the priority. Override this default behavior by setting a value from 1 to 255." ::= {adTa5kSmProvEntry 27 } adTa5kSmExtBPriority OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Select the priority for External Clock B. Set adTa5kSmExtBPriority to 0 to use the node number as the priority. Override this default behavior by setting a value from 1 to 255." ::= {adTa5kSmProvEntry 28 } adTa5kSmInternalSTag OBJECT-TYPE SYNTAX Integer32 (2..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "S-Tag returned for internal data/configuration traffic." ::= {adTa5kSmProvEntry 29 } adTa5kSmBpRateAlarmSeverityLevel OBJECT-TYPE SYNTAX INTEGER { alert(3), minor(4), major(5), critical(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Provision the severity level of BpRateFallback alarm." ::= {adTa5kSmProvEntry 30 } adTa5kSmNetworkPortProvTable OBJECT-TYPE SYNTAX SEQUENCE OF AdTa5kSmNetworkPortProvEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "..." ::= { adTa5kSmProv 2 } adTa5kSmNetworkPortProvEntry OBJECT-TYPE SYNTAX AdTa5kSmNetworkPortProvEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is indexed by the ifIndex of each Switch Module faceplate port." INDEX { ifIndex } ::= { adTa5kSmNetworkPortProvTable 1 } AdTa5kSmNetworkPortProvEntry ::= SEQUENCE { adTa5kSmPortMode INTEGER, adTa5kSmLACPMode INTEGER } adTa5kSmPortMode OBJECT-TYPE SYNTAX INTEGER { unused (1), networkInterface (2), uplink (3), downlink (4), erps (5) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This value determines the how this port affects SM redundancy decisions. Unused (1) - this port is ignored in redundancy decisions. Use this setting for ports that are not in use, or any port that does not need to be considered in redundancy decisions. Network Interface (2) - Set adTa5kSmRedundancyMode to 2 only in Node 1, Shelf 1. Indicates that this port is connected to an upstream router or other non-TA5000 networking equipment. Uplink (3) - Indicates that this port is connected to an upstream TA5000 Node. Downlink (4) - Indicates that this port is connected to a downstream TA5000 Node. ERPS (5) - Indicates that this port participates in an ERPS ring, and thus supports ERPS timing, but is ignored for redundancy decisions." ::= {adTa5kSmNetworkPortProvEntry 1} adTa5kSmLACPMode OBJECT-TYPE SYNTAX INTEGER { disabled (1), active (2), passive (3) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "LACP Mode for the network port." ::= {adTa5kSmNetworkPortProvEntry 2} adTa5kSmEthernetDefaultInterface OBJECT IDENTIFIER ::= { adTa5kSmProv 3 } adTa5kSmEthDefaultInterfaceIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-write STATUS current DESCRIPTION "The IfIndex of the ethernet default interface. A value of zero indicates no ethernet default interface. ** Warning ** Setting adTa5kSmEthDefaultInterfaceIndex can disable remote management of this system." ::= { adTa5kSmEthernetDefaultInterface 1 } EthernetDefaultInterfaceType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Specifies the interface types which may be the ethernet default interface." SYNTAX INTEGER { none(1), gigabitEthernet(2), tenGigabitEthernet(3), lagGroup(4), accessModule(5), efmGroup(6), efmPort(7), erps(8), atmPort(9), rpr(10), atmGroup(11), muxponderSlot(12), xGigabitEthernet(13) } adTa5kSmEthernetDefaultIfcType OBJECT-TYPE SYNTAX EthernetDefaultInterfaceType MAX-ACCESS read-only STATUS current DESCRIPTION "The ethernet default interface type." ::= {adTa5kSmEthernetDefaultInterface 2} adTa5kSmEthernetDefaultIfcSlot OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The ethernet default interface slot. Slots 1-22 represent access module slots. Slot 239 is the active SM slot. Slot 252 is SM-A. Slot 253 is SM-B. adTa5kSmEthernetDefaultIfcSlot will return 0 if adTa5kSmEthernetDefaultIfcType = none(1)." ::= {adTa5kSmEthernetDefaultInterface 3} adTa5kSmEthernetDefaultIfcPort OBJECT-TYPE SYNTAX INTEGER(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The ethernet default interface port. This value may represent a physical port or a logical port. For example, if the ethernet default interface is gigabit-ethernet 1/A/2, then adTa5kSmEthernetDefaultIfcPort = physical port 2. If the ethernet default interface is lag-group 1/A/1, then adTa5kSmEthernetDefaultIfcPort = 1 to indicate lag-group #1 on slot A. adTa5kSmEthernetDefaultIfcPort will return 0 if adTa5kSmEthernetDefaultIfcType = none(1)." ::= {adTa5kSmEthernetDefaultInterface 4} -- ****************************************************************************************** -- Alarm Provisioning -- ****************************************************************************************** adTa5kSmAlarmProvTable OBJECT-TYPE SYNTAX SEQUENCE OF AdTa5kSmAlarmProvEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "..." ::= { adTa5kSmProv 4 } adTa5kSmAlarmProvEntry OBJECT-TYPE SYNTAX AdTa5kSmAlarmProvEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "..." INDEX { adGenSlotInfoIndex } ::= { adTa5kSmAlarmProvTable 1 } AdTa5kSmAlarmProvEntry ::= SEQUENCE { adTa5kSmRingGenFailAlarmEnable TruthValue, adTa5kSmPowerLimitExceededAlarmEnable TruthValue, adTa5kSmDuplicateNodeAlarmEnable TruthValue, adTa5kSmDuplicateScmIpAlarmEnable TruthValue, adTa5kSmNodeNumberProvAlarmEnable TruthValue, adTa5kSmMgmtVlanFailAlarmEnable TruthValue, adTa5kSmioMismatchAlarmEnable TruthValue, adTa5kSmBPRateFallbackAlarmEnable TruthValue, adTa5kSmPeerLinksDownAlarmEnable TruthValue } adTa5kSmRingGenFailAlarmEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "True - alarm is enabled" DEFVAL {true} ::= { adTa5kSmAlarmProvEntry 1 } adTa5kSmPowerLimitExceededAlarmEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "True - alarm is enabled" DEFVAL {true} ::= { adTa5kSmAlarmProvEntry 2 } adTa5kSmDuplicateNodeAlarmEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "True - alarm is enabled" DEFVAL {true} ::= { adTa5kSmAlarmProvEntry 3 } adTa5kSmDuplicateScmIpAlarmEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "True - alarm is enabled" DEFVAL {true} ::= { adTa5kSmAlarmProvEntry 4 } adTa5kSmNodeNumberProvAlarmEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "True - alarm is enabled" DEFVAL {true} ::= { adTa5kSmAlarmProvEntry 5 } adTa5kSmMgmtVlanFailAlarmEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "True - alarm is enabled" DEFVAL {true} ::= { adTa5kSmAlarmProvEntry 6 } adTa5kSmioMismatchAlarmEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "True - alarm is enabled" DEFVAL {true} ::= { adTa5kSmAlarmProvEntry 7 } adTa5kSmBPRateFallbackAlarmEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "True - alarm is enabled" DEFVAL {true} ::= { adTa5kSmAlarmProvEntry 8 } adTa5kSmPeerLinksDownAlarmEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "True - alarm is enabled" DEFVAL {true} ::= { adTa5kSmAlarmProvEntry 9 } -- *************************************************************** -- Status Items -- *************************************************************** adTa5kSmClockStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AdTa5kSmClockStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "..." ::= { adTa5kSmStatus 1 } adTa5kSmClockStatusEntry OBJECT-TYPE SYNTAX AdTa5kSmClockStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "..." INDEX { adGenSlotInfoIndex } ::= { adTa5kSmClockStatusTable 1 } AdTa5kSmClockStatusEntry ::= SEQUENCE { adTa5kSmLoopAClockHealth INTEGER, adTa5kSmLoopBClockHealth INTEGER, adTa5kSmBitsAClockHealth INTEGER, adTa5kSmBitsBClockHealth INTEGER, adTa5kSmPrimaryClockHealth INTEGER, adTa5kSmSecondaryClockHealth INTEGER, adTa5kSmRingVoltagePresent Integer32, adTa5kSmRingFail Integer32, adTa5kSmPeerRingFail Integer32, adTa5kSmCurrentHopCount INTEGER, adTa5kSmCurrentTimingSourcePriority INTEGER, adTa5kSmCurrentTimingSourceQuality INTEGER } adTa5kSmLoopAClockHealth OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Displays the health of the loop A timing source" ::= { adTa5kSmClockStatusEntry 1 } adTa5kSmLoopBClockHealth OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Displays the health of the loop B timing source" ::= { adTa5kSmClockStatusEntry 2 } adTa5kSmBitsAClockHealth OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Displays the health of the bits A timing source" ::= { adTa5kSmClockStatusEntry 3 } adTa5kSmBitsBClockHealth OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Displays the health of the bits B timing source" ::= { adTa5kSmClockStatusEntry 4 } adTa5kSmPrimaryClockHealth OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Displays the health of the primary timing source" ::= { adTa5kSmClockStatusEntry 5 } adTa5kSmSecondaryClockHealth OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Displays the health of the secondary timing source" ::= { adTa5kSmClockStatusEntry 6 } adTa5kSmRingVoltagePresent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Boolean, 0 - Ring voltage is not present, 1 - Ring voltage is present. If you are not using an internal ring generator then this could indicate that the external ring voltage source has failed or is not connected." ::= { adTa5kSmClockStatusEntry 7 } adTa5kSmRingFail OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Boolean, 0 - Not Failed, 1 - Failed." ::= { adTa5kSmClockStatusEntry 8 } adTa5kSmPeerRingFail OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Boolean, 0 - Not Failed, 1 - Failed." ::= { adTa5kSmClockStatusEntry 9 } adTa5kSmCurrentHopCount OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The number of hops for the current timing source." ::= { adTa5kSmClockStatusEntry 10 } adTa5kSmCurrentTimingSourcePriority OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The priority value for the current timing source." ::= { adTa5kSmClockStatusEntry 11 } adTa5kSmCurrentTimingSourceQuality OBJECT-TYPE SYNTAX INTEGER { stratum1 (1), synchronized (2), stratum2 (3), transmitModeClock (4), stratum3e (5), stratum3 (6), sonetClock (7), stratum4or4e (8), doNotUseForSync (15) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The quality of the current timing source." ::= { adTa5kSmClockStatusEntry 12 } -- *************************************************************** adTa5kSmMetalicTestAccessTable OBJECT-TYPE SYNTAX SEQUENCE OF AdTa5kSmMetalicTestAccessEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "..." ::= { adTa5kSmTest 1 } adTa5kSmMetalicTestAccessEntry OBJECT-TYPE SYNTAX AdTa5kSmMetalicTestAccessEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "..." INDEX { adGenSlotInfoIndex } ::= { adTa5kSmMetalicTestAccessTable 1 } AdTa5kSmMetalicTestAccessEntry ::= SEQUENCE { adTa5kSmFacilityTR INTEGER, adTa5kSmFacilityT1R1 INTEGER, adTa5kSmEquipmentTR INTEGER, adTa5kSmEquipmentT1R1 INTEGER, adTa5kSmLoopTR INTEGER, adTa5kSmLoopT1R1 INTEGER } adTa5kSmFacilityTR OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2), notApplicable (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { adTa5kSmMetalicTestAccessEntry 1 } adTa5kSmFacilityT1R1 OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2), notApplicable (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { adTa5kSmMetalicTestAccessEntry 2 } adTa5kSmEquipmentTR OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2), notApplicable (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { adTa5kSmMetalicTestAccessEntry 3 } adTa5kSmEquipmentT1R1 OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2), notApplicable (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { adTa5kSmMetalicTestAccessEntry 4 } adTa5kSmLoopTR OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2), notApplicable (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { adTa5kSmMetalicTestAccessEntry 5 } adTa5kSmLoopT1R1 OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2), notApplicable (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { adTa5kSmMetalicTestAccessEntry 6 } -- *************************************************************** adTa5kSmAtpTable OBJECT-TYPE SYNTAX SEQUENCE OF AdTa5kSmAtpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "..." ::= { adTa5kSmAtpMfg 1 } adTa5kSmAtpEntry OBJECT-TYPE SYNTAX AdTa5kSmAtpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "..." INDEX { adGenSlotInfoIndex } ::= { adTa5kSmAtpTable 1 } AdTa5kSmAtpEntry ::= SEQUENCE { adTa5kSmTemp1 Integer32, adTa5kSmTemp2 Integer32, adTa5kSmExpMac OCTET STRING, adTa5kSmPeerMac OCTET STRING } adTa5kSmTemp1 OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Upper Temp sensor: Temperature in tenths of a degrees C." ::= { adTa5kSmAtpEntry 1 } adTa5kSmTemp2 OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Lower Temp sensor: Temperature in tenths of a degrees C." ::= { adTa5kSmAtpEntry 2 } adTa5kSmExpMac OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Mac Address of the Expansion Port." ::= { adTa5kSmAtpEntry 3 } adTa5kSmPeerMac OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Mac Address of the internal link between the SM and its peer." ::= { adTa5kSmAtpEntry 4 } -- ------------------------------------- -- Switch Module Alarms -- ------------------------------------- adTa5kSmTimingSrcClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName } STATUS deprecated DESCRIPTION "Indicates that the primary and/or secondary timing source alarm has cleared" --#TYPE "Status - Timing Src Alarm Clear" --#SUMMARY "TA5000 Switch Module: Timing Source Cleared on" --#SUMMARY "Shelf: %s" --#ARGUMENTS {1} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 2 } adTa5kSmTimingSrcFail NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName } STATUS deprecated DESCRIPTION "Indicates that the primary and/or secondary timing source has failed" --#TYPE "Status - Timing Src Alarm Active" --#SUMMARY "TA5000 Switch Module: Timing Source Failure on" --#SUMMARY "Shelf: %s" --#ARGUMENTS {1} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 3 } adTa5kSmRingGenClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName } STATUS current DESCRIPTION "Indicates ring generator alarm clear" --#TYPE "Status - Ring Generator Alarm Clear" --#SUMMARY "TA5000 Switch Module: Ring Generator Alarm Cleared on" --#SUMMARY "Shelf: %s" --#ARGUMENTS {1} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 4 } adTa5kSmRingGenFail NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName } STATUS current DESCRIPTION "Indicates that the ring generator has failed" --#TYPE "Status - Ring Generator Alarm Active" --#SUMMARY "TA5000 Switch Module: Ring Generator Failure on" --#SUMMARY "Shelf: %s" --#ARGUMENTS {1} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 5 } adTa5kSmPowerLimitAlmClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName } STATUS current DESCRIPTION "Indicates that the power limit alarm has cleared" --#TYPE "Status - Power Limit Alarm Clear" --#SUMMARY "TA5000 Switch Module: Power Limit Alarm Cleared on" --#SUMMARY "Shelf: %s" --#ARGUMENTS {1} --#SEVERITY MAJOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 6 } adTa5kSmPowerLimitExceeded NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName } STATUS current DESCRIPTION "Indicates that the shelf power limit has been exceeded" --#TYPE "Status - Power Limit Alarm Active" --#SUMMARY "TA5000 Switch Module: Power Limit Exceeded On" --#SUMMARY "Shelf: %s" --#ARGUMENTS {1} --#SEVERITY MAJOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 7 } adTa5kSmUnknownSfpClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adGenPortTrapIdentifier } STATUS current DESCRIPTION "Indicates that the unknown SFP alarm has cleared" --#TYPE "Status - Unknown SFP Alarm Clear" --#SUMMARY "TA5000 Switch Module: Unknown SFP Alarm Cleared on" --#SUMMARY "Shelf: %s Slot, Port: %s" --#ARGUMENTS {1,3} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 8 } adTa5kSmUnknownSfpAlarm NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adGenPortTrapIdentifier } STATUS current DESCRIPTION "Indicates that the unknown SFP alarm is active" --#TYPE "Status - Unknown SFP Alarm" --#SUMMARY "TA5000 Switch Module: Unknown SFP Alarm on" --#SUMMARY "Shelf: %s Slot, Port: %s" --#ARGUMENTS {1,3} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 9 } adTa5kSmSfpFaultClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adGenPortTrapIdentifier } STATUS current DESCRIPTION "Indicates that the SFP fault has cleared" --#TYPE "Status - SFP Fault Clear" --#SUMMARY "TA5000 Switch Module: SFP Fault Cleared on" --#SUMMARY "Shelf: %s Slot, Port: %s" --#ARGUMENTS {1,3} --#SEVERITY MAJOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 10 } adTa5kSmSfpFaultActive NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adGenPortTrapIdentifier } STATUS current DESCRIPTION "Indicates that the SFP fault is active" --#TYPE "Status - SFP Fault Active" --#SUMMARY "TA5000 Switch Module: SFP Fault Active on" --#SUMMARY "Shelf: %s Slot, Port: %s" --#ARGUMENTS {1,3} --#SEVERITY MAJOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 11 } adTa5kSmMultipleUplinksClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex } STATUS deprecated DESCRIPTION "Indicates that the multiple uplink alarm has cleared" --#TYPE "Status - Multiple Uplink Alarm Clear" --#SUMMARY "TA5000 Switch Module: Multiple Uplink Alarm Cleared on" --#SUMMARY "Shelf: %s, Slot %d" --#ARGUMENTS {1, 2} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 12 } adTa5kSmMultipleUplinksDetected NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex } STATUS deprecated DESCRIPTION "Indicates that multiple uplinks have been detected" --#TYPE "Status - Multiple Uplink Alarm Active" --#SUMMARY "TA5000 Switch Module: Multiple Uplink Alarm Active on" --#SUMMARY "Shelf: %s, Slot %d" --#ARGUMENTS {1, 2} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 13 } adTa5kSmExtAFailureClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex } STATUS current DESCRIPTION "Indicates that the ExtA timing failure has been cleared" --#TYPE "Status - ExtA Timing Failure Clear" --#SUMMARY "TA5000 Switch Module: ExtA Timing Failure Cleared On" --#SUMMARY "Shelf: %s, Slot %d" --#ARGUMENTS {1, 2} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 14 } adTa5kSmExtAFailureActive NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex } STATUS current DESCRIPTION "Indicates that the ExtA timing has failed" --#TYPE "Status - ExtA Timing Failure Active" --#SUMMARY "TA5000 Switch Module: ExtA Timing Failure Active On" --#SUMMARY "Shelf: %s, Slot %d" --#ARGUMENTS {1, 2} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 15 } adTa5kSmExtBFailureClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex } STATUS current DESCRIPTION "Indicates that the ExtB timing failure has been cleared" --#TYPE "Status - ExtB Timing Failure Clear" --#SUMMARY "TA5000 Switch Module: ExtB Timing Failure Cleared On" --#SUMMARY "Shelf: %s, Slot %d" --#ARGUMENTS {1, 2} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 16 } adTa5kSmExtBFailureActive NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex } STATUS current DESCRIPTION "Indicates that the ExtA timing has failed" --#TYPE "Status - ExtB Timing Failure Active" --#SUMMARY "TA5000 Switch Module: ExtB Timing Failure Active On" --#SUMMARY "Shelf: %s, Slot %d" --#ARGUMENTS {1, 2} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 17 } adTa5kSmLossOfHeartbeatClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adGenPortTrapIdentifier } STATUS current DESCRIPTION "Indicates that the loss of heartbeat alarm cleared" --#TYPE "Status - Loss of Heartbeat Clear" --#SUMMARY "TA5000 Switch Module: Loss of Heartbeat Alarm Cleared on" --#SUMMARY "Shelf: %s Slot, Port: %s" --#ARGUMENTS {1,3} --#SEVERITY MAJOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 18 } adTa5kSmLossOfHeartbeatActive NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adGenPortTrapIdentifier } STATUS current DESCRIPTION "Indicates that the loss of heartbeat alarm is active" --#TYPE "Status - Loss of Heartbeat Alarm Active" --#SUMMARY "TA5000 Switch Module: Loss of Heartbeat Alarm Active on" --#SUMMARY "Shelf: %s Slot, Port: %s" --#ARGUMENTS {1,3} --#SEVERITY MAJOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 19 } adTa5kSmLossOfNetworkStpClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adGenPortTrapIdentifier } STATUS deprecated DESCRIPTION "Indicates that the loss of network STP alarm cleared" --#TYPE "Status - Loss of Network STP Clear" --#SUMMARY "TA5000 Switch Module: Loss of Network STP Alarm Cleared on" --#SUMMARY "Shelf: %s Slot, Port: %s" --#ARGUMENTS {1,3} --#SEVERITY MAJOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 20 } adTa5kSmLossOfNetworkStpActive NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adGenPortTrapIdentifier } STATUS deprecated DESCRIPTION "Indicates that the loss of network STP alarm active" --#TYPE "Status - Loss of Network STP Active" --#SUMMARY "TA5000 Switch Module: Loss of Network STP Alarm Active on" --#SUMMARY "Shelf: %s Slot, Port: %s" --#ARGUMENTS {1,3} --#SEVERITY MAJOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 21 } adTa5kSmDuplicateNodeClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adTa5kSmNode } STATUS current DESCRIPTION "Indicates that the duplicate node alarm has been cleared" --#TYPE "Status - Duplicate Node Alarm Clear" --#SUMMARY "TA5000 Switch Module: Duplicate Node Alarm Cleared On" --#SUMMARY "Shelf: %s, Slot %d, Node %d" --#ARGUMENTS {1, 2, 3} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 22 } adTa5kSmDuplicateNodeActive NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adTa5kSmNode } STATUS current DESCRIPTION "Indicates that the duplicate node alarm is active" --#TYPE "Status - Duplicate Node Alarm Clear" --#SUMMARY "TA5000 Switch Module: Duplicate Node Alarm Active on" --#SUMMARY "Shelf: %s, Slot %d, Node %d" --#ARGUMENTS {1, 2, 3} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 23 } adTa5kSmDuplicateScmIpClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex } STATUS current DESCRIPTION "Indicates that the duplicate SCM IP address alarm has been cleared" --#TYPE "Status - Duplicate SCM IP Address Alarm Clear" --#SUMMARY "TA5000 Switch Module: Duplicate SCM IP Address Alarm Cleared On" --#SUMMARY "Shelf: %s, Slot %d" --#ARGUMENTS {1, 2} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 24 } adTa5kSmDuplicateScmIpActive NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex } STATUS current DESCRIPTION "Indicates that the duplicate SCM IP address alarm is active" --#TYPE "Status - Duplicate SCM IP Address Alarm Active" --#SUMMARY "TA5000 Switch Module: Duplicate SCM IP Address Alarm on" --#SUMMARY "Shelf: %s, Slot %d" --#ARGUMENTS {1, 2} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 25 } adTa5kSmBandwidthFullClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adGenPortTrapIdentifier } STATUS current DESCRIPTION "Indicates that the Bandwidth full alarm has been cleared" --#TYPE "Status - Bandwidth Full Alarm Clear" --#SUMMARY "TA5000 Switch Module: Bandwidth Full Alarm Cleared On" --#SUMMARY "Shelf: %s, Slot, Node: %s" --#ARGUMENTS {1, 3} --#SEVERITY MAJOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 26 } adTa5kSmBandwidthFull NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adGenPortTrapIdentifier } STATUS current DESCRIPTION "Indicates that the Bandwidth full alarm is active" --#TYPE "Status - Bandwidth Full Alarm" --#SUMMARY "TA5000 Switch Module: Bandwidth Full Alarm Active On" --#SUMMARY "Shelf: %s, Slot, Node: %s" --#ARGUMENTS {1, 3} --#SEVERITY MAJOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 27 } adTa5kSmPriTimingSrcClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName } STATUS deprecated DESCRIPTION "Indicates that the primary timing source alarm has cleared" --#TYPE "Status - Primary Timing Src Alarm Clear" --#SUMMARY "TA5000 Switch Module: Timing Source Cleared on" --#SUMMARY "Shelf: %s" --#ARGUMENTS {1} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 28 } adTa5kSmPriTimingSrcFail NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName } STATUS deprecated DESCRIPTION "Indicates that the primary timing source has failed" --#TYPE "Status - Primary Timing Src Alarm Active" --#SUMMARY "TA5000 Switch Module: Timing Source Failure on" --#SUMMARY "Shelf: %s" --#ARGUMENTS {1} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 29 } adTa5kSmSecTimingSrcClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName } STATUS deprecated DESCRIPTION "Indicates that the secondary timing source alarm has cleared" --#TYPE "Status - Secondary Timing Src Alarm Clear" --#SUMMARY "TA5000 Switch Module: Timing Source Cleared on" --#SUMMARY "Shelf: %s" --#ARGUMENTS {1} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 30 } adTa5kSmSecTimingSrcFail NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName } STATUS deprecated DESCRIPTION "Indicates that the secondary timing source has failed" --#TYPE "Status - Secondary Timing Src Alarm Active" --#SUMMARY "TA5000 Switch Module: Timing Source Failure on" --#SUMMARY "Shelf: %s" --#ARGUMENTS {1} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 31 } adTa5kSmNodeNumberProvClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName } STATUS current DESCRIPTION "Indicates that the shelf's node number has been provisioned and is not zero." --#TYPE "Status - SM Node Number Alarm Clear" --#SUMMARY "TA5000 Switch Module: Node Number Alarm Cleared on" --#SUMMARY "Shelf: %s" --#ARGUMENTS {1} --#SEVERITY WARNING --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 32 } adTa5kSmNodeNumberDefault NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName } STATUS current DESCRIPTION "Indicates that the shelf's node number has not been provisioned." --#TYPE "Status - SM Node Number Alarm" --#SUMMARY "TA5000 Switch Module: Node Number Alarm on" --#SUMMARY "Shelf: %s" --#ARGUMENTS {1} --#SEVERITY WARNING --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 33 } adTa5kSmMgmtVlanFailClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex } STATUS current DESCRIPTION "Indicates that the SM's failure to communicate the Internal Management VLAN to an access module has cleared." --#TYPE "Status - Internal Mgmt VLAN Alarm Clear" --#SUMMARY "TA5000 Switch Module: Internal Mgmt VLAN Alarm Cleared on" --#SUMMARY "Shelf: %s, Slot: %d" --#ARGUMENTS {1, 2} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 34 } adTa5kSmMgmtVlanFail NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex } STATUS current DESCRIPTION "Indicates that the SM has failed to communicate the Internal Management VLAN to an access module." --#TYPE "Status - Internal Mgmt VLAN Alarm" --#SUMMARY "TA5000 Switch Module: Internal Mgmt VLAN Alarm on" --#SUMMARY "Shelf: %s, Slot: %d" --#ARGUMENTS {1, 2} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 35 } adTa5kSmioMismatchClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex } STATUS current DESCRIPTION "Indicates that either there is no hardware incompatibility among the SM cards and SMIO Or ERPS/CSLAG is not provisioned." --#TYPE "Status - incompatible SMIO alarm cleared" --#SUMMARY "TA5000 Switch Module: no hardware incompatibility among the SM and SMIO Or ERPS/CSLAG is not provisioned." --#SUMMARY "Shelf: %s, Slot %d" --#ARGUMENTS {1, 2} --#SEVERITY MAJOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 36 } adTa5kSmioMismatch NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex } STATUS current DESCRIPTION "Indicates that attempts for provisioning of ERPS or CSLAG is made and hardware incompatibility detected among SM and SMIO" --#TYPE "Status - incompatible SMIO" --#SUMMARY "TA5000 Switch Module: Attempts for provisioning of ERPS or CSLAG is made and hardware incompatibility detected among SM and SMIO" --#SUMMARY "Shelf: %s, Slot %d" --#ARGUMENTS {1, 2} --#SEVERITY MAJOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 37 } adTa5kSmBackPlaneRateFallbackClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, ifIndex, adTAeSCUTrapAlarmLevel } STATUS current DESCRIPTION "Indicates that the AM is out of Backplane Rate Fallback mode. adGenSlotInfoIndex indicates the slot of the card sending the alarm, which is always the active SM. ifIndex indicates the associated backplane port interface at fault." --#TYPE "Status - BackPlane Rate Fallback Alarm Active" --#SUMMARY "TA5000 Switch Module: BackPlane Rate Fallback Alarm on" --#SUMMARY "Shelf: %s, Slot: %d, Port: %d" --#ARGUMENTS {1, 2, 3} --#SEVERITY ALERT --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 38 } adTa5kSmBackPlaneRateFallback NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, ifIndex, adTAeSCUTrapAlarmLevel } STATUS current DESCRIPTION "Indicates that the AM is in Backplane Rate Fallback mode. adGenSlotInfoIndex indicates the slot of the card sending the alarm, which is always the active SM. ifIndex indicates the associated backplane port interface at fault." --#TYPE "Status - BackPlane Rate Fallback Alarm Active" --#SUMMARY "TA5000 Switch Module: BackPlane Rate Fallback Alarm on" --#SUMMARY "Shelf: %s, Slot: %d, Port: %d" --#ARGUMENTS {1, 2, 3} --#SEVERITY ALERT --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 39 } adTa5kSmPeerLinkDownClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, ifIndex, ifDescr } STATUS current DESCRIPTION "Indicates that the link status of the high speed peer interface between redundant switch modules is up. ifIndex indicates the associated peer port interface" --#TYPE "Status - peer link down alarm cleared" --#SUMMARY "TA5000 Switch Module: Peer Link Down Alarm cleared" --#SUMMARY "Shelf: %s, Slot: %d, Port: %d" --#ARGUMENTS {1, 2, 3} --#SEVERITY MAJOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 40 } adTa5kSmPeerLinkDown NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, ifIndex, ifDescr } STATUS current DESCRIPTION "Indicates that the link status of the high speed peer interface between redundant switch modules is down. ifIndex indicates the associated peer port interface" --#TYPE "Status - peer link down alarm Active" --#SUMMARY "TA5000 Switch Module: Peer Link Down Alarm on" --#SUMMARY "Shelf: %s, Slot: %d, Port: %d" --#ARGUMENTS {1, 2, 3} --#SEVERITY MAJOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 41 } adTa5kSmBackPlaneIncompatibleClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex } STATUS current DESCRIPTION "Indicates that the Backplane Incompatible alarm has been cleared." --#TYPE "Status - Backplane Incompatible alarm cleared" --#SUMMARY "TA5000 Switch Module: Slot Backplane Incompatible alarm cleared." --#SUMMARY "Shelf: %s, Slot: %d, " --#ARGUMENTS {1, 2} --#SEVERITY Major --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 42 } adTa5kSmBackPlaneIncompatibleActive NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex } STATUS current DESCRIPTION "Indicates that SM cards are not capable of full backplane speeds to some slots in the chassis." --#TYPE "Status - Backplane Incompatible alarm is active" --#SUMMARY "TA5000 Switch Module: not capable of full backplane speeds to some slots in the chassis." --#SUMMARY "Shelf: %s, Slot: %d, " --#ARGUMENTS {1, 2} --#SEVERITY Major --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTa5kSmAlarms 43 } END