126 lines
4.1 KiB
Plaintext
126 lines
4.1 KiB
Plaintext
ADTRAN-TA5K-FXS-FAC-MIB
|
|
|
|
-- TITLE: The ADTRAN TA5000 FXS Factory MIB
|
|
-- PRODUCT: TA5000
|
|
-- VERSION: 1.0
|
|
-- DATE: 11/09/11
|
|
-- AUTHOR: Peter Kerr
|
|
-- STATUS: PRELIMINARY
|
|
|
|
-- This MIB defines the object identifiers (OIDs) for use
|
|
-- during factory calibration tests involving TA5000 FXS
|
|
-- products.
|
|
|
|
-- *****************************************************************************
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
|
|
OBJECT-TYPE,
|
|
MODULE-IDENTITY
|
|
FROM SNMPv2-SMI
|
|
|
|
TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
|
|
adTa5kFxsFac,
|
|
adTa5kFxsFacID
|
|
FROM ADTRAN-GENTA5K-MIB
|
|
|
|
adGenSlotInfoIndex
|
|
FROM ADTRAN-GENSLOT-MIB
|
|
;
|
|
|
|
-- *****************************************************************************
|
|
|
|
adTa5kFxsFacIdentity MODULE-IDENTITY
|
|
LAST-UPDATED "201111090000Z"
|
|
ORGANIZATION "Adtran, Inc."
|
|
CONTACT-INFO
|
|
"CND Tech Support
|
|
Postal: ADTRAN, Inc.
|
|
901 Explorer Blvd.
|
|
Huntsville, AL 35806
|
|
Tel: +1 800 726-8663
|
|
Fax: +1 256 963 6217
|
|
E-mail: support@adtran.com"
|
|
DESCRIPTION
|
|
"This MIB defines the object identifiers (OIDs) for use
|
|
during factory calibration tests involving TA5000 FXS
|
|
products."
|
|
REVISION "201111090000Z"
|
|
DESCRIPTION "Created"
|
|
::= { adTa5kFxsFacID 1 }
|
|
|
|
--==============================================================================
|
|
-- Limited THL test table
|
|
--==============================================================================
|
|
|
|
adTa5kFxsFacLimitedThlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdTa5kFxsFacLimitedThlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Limited THL test is used during the factory calibration of the
|
|
TA5000 CPOTS Module (1187160F1). It sends three tones port port towards
|
|
the CPOTS module, which should be off-hook, and measures the resultant
|
|
Echo Return Loss (ERL)."
|
|
::= { adTa5kFxsFac 1 }
|
|
|
|
adTa5kFxsFacLimitedThlEntry OBJECT-TYPE
|
|
SYNTAX AdTa5kFxsFacLimitedThlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"..."
|
|
INDEX { adGenSlotInfoIndex }
|
|
::= { adTa5kFxsFacLimitedThlTable 1 }
|
|
|
|
AdTa5kFxsFacLimitedThlEntry ::=
|
|
SEQUENCE {
|
|
adTa5kFxsFacLimitedThlStart INTEGER,
|
|
adTa5kFxsFacLimitedThlStatus INTEGER,
|
|
adTa5kFxsFacLimitedThlResults OCTET STRING
|
|
}
|
|
|
|
adTa5kFxsFacLimitedThlStart OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
begin(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to start the test."
|
|
::= { adTa5kFxsFacLimitedThlEntry 1 }
|
|
|
|
adTa5kFxsFacLimitedThlStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
na(1),
|
|
complete(2),
|
|
fault(3),
|
|
running(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use to monitor test progress:
|
|
1 = na Returned when test has never been run.
|
|
2 = complete Returned once test has completed successfully.
|
|
3 = fault Returned if test aborted due to a failure.
|
|
4 = running Returned while test is in progress."
|
|
::= { adTa5kFxsFacLimitedThlEntry 2 }
|
|
|
|
adTa5kFxsFacLimitedThlResults OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..256))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns a vector of 32-bit unsigned integers (split into octets
|
|
containing the measured ERL for each port of the card under test
|
|
in mdB units. The first uint32 is always empty. The first port
|
|
can be found in the second unint32."
|
|
::= { adTa5kFxsFacLimitedThlEntry 3 }
|
|
|
|
END
|
|
|