Observium_CE/mibs/adtran/ADTRAN-TA5K-FXS-FAC-MIB

126 lines
4.1 KiB
Plaintext

ADTRAN-TA5K-FXS-FAC-MIB
-- TITLE: The ADTRAN TA5000 FXS Factory MIB
-- PRODUCT: TA5000
-- VERSION: 1.0
-- DATE: 11/09/11
-- AUTHOR: Peter Kerr
-- STATUS: PRELIMINARY
-- This MIB defines the object identifiers (OIDs) for use
-- during factory calibration tests involving TA5000 FXS
-- products.
-- *****************************************************************************
DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE,
MODULE-IDENTITY
FROM SNMPv2-SMI
TEXTUAL-CONVENTION
FROM SNMPv2-TC
adTa5kFxsFac,
adTa5kFxsFacID
FROM ADTRAN-GENTA5K-MIB
adGenSlotInfoIndex
FROM ADTRAN-GENSLOT-MIB
;
-- *****************************************************************************
adTa5kFxsFacIdentity MODULE-IDENTITY
LAST-UPDATED "201111090000Z"
ORGANIZATION "Adtran, Inc."
CONTACT-INFO
"CND Tech Support
Postal: ADTRAN, Inc.
901 Explorer Blvd.
Huntsville, AL 35806
Tel: +1 800 726-8663
Fax: +1 256 963 6217
E-mail: support@adtran.com"
DESCRIPTION
"This MIB defines the object identifiers (OIDs) for use
during factory calibration tests involving TA5000 FXS
products."
REVISION "201111090000Z"
DESCRIPTION "Created"
::= { adTa5kFxsFacID 1 }
--==============================================================================
-- Limited THL test table
--==============================================================================
adTa5kFxsFacLimitedThlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdTa5kFxsFacLimitedThlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Limited THL test is used during the factory calibration of the
TA5000 CPOTS Module (1187160F1). It sends three tones port port towards
the CPOTS module, which should be off-hook, and measures the resultant
Echo Return Loss (ERL)."
::= { adTa5kFxsFac 1 }
adTa5kFxsFacLimitedThlEntry OBJECT-TYPE
SYNTAX AdTa5kFxsFacLimitedThlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"..."
INDEX { adGenSlotInfoIndex }
::= { adTa5kFxsFacLimitedThlTable 1 }
AdTa5kFxsFacLimitedThlEntry ::=
SEQUENCE {
adTa5kFxsFacLimitedThlStart INTEGER,
adTa5kFxsFacLimitedThlStatus INTEGER,
adTa5kFxsFacLimitedThlResults OCTET STRING
}
adTa5kFxsFacLimitedThlStart OBJECT-TYPE
SYNTAX INTEGER {
begin(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to start the test."
::= { adTa5kFxsFacLimitedThlEntry 1 }
adTa5kFxsFacLimitedThlStatus OBJECT-TYPE
SYNTAX INTEGER {
na(1),
complete(2),
fault(3),
running(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Use to monitor test progress:
1 = na Returned when test has never been run.
2 = complete Returned once test has completed successfully.
3 = fault Returned if test aborted due to a failure.
4 = running Returned while test is in progress."
::= { adTa5kFxsFacLimitedThlEntry 2 }
adTa5kFxsFacLimitedThlResults OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..256))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns a vector of 32-bit unsigned integers (split into octets
containing the measured ERL for each port of the card under test
in mdB units. The first uint32 is always empty. The first port
can be found in the second unint32."
::= { adTa5kFxsFacLimitedThlEntry 3 }
END