Observium_CE/mibs/adtran/ADTRAN-GENCHASSISTRAP-MIB

358 lines
13 KiB
Plaintext

ADTRAN-GENCHASSISTRAP-MIB DEFINITIONS ::= BEGIN
-- TITLE: Generic chassis trap MIB
-- PRODUCT: All chassis type products
-- VERSION: 1.0
-- DATE: 00/06/26
-- AUTHOR: Theresa Chard
-- SNMP: SNMPv1
-- MIB ARC: adtran.adShared.adGenericShelves
-- FILE: genctrap.mib
-- HISTORY:
-- 06/26/00 tgc defined card removal and insertion traps
-- 08/10/00 pnb insert all generic chassis traps
-- clarify that link up/link down are mgmt links (AMCP)
-- change link down cleared to link up
-- removed blown fuse alarm clear - can't happen
-- removed unknown card fuse blown - superfluous
-- 09/28/00 pnb converted trap sequence number to object in genport.mib
-- since all trap objects were allocated to gentrap.mib.
-- This changed MO name from adGenChassisSeqNum to
-- adTrapInformSeqNum
-- 04/03/01 pnb Removed mgmtup/down link traps, and removed superfluous
-- varbinds from others. Added prefix to all trap names.
-- 04/06/01 pnb Removed 6th major alarm traps.
-- 05/09/01 pnb Add service state traps
-- 05/10/01 pnb Added comment about previously used OIDs.
-- 05/10/01 pnb Changed all names to reduce size for HP OpenView limitations
IMPORTS
sysName
FROM RFC1213-MIB
TRAP-TYPE
FROM RFC-1215
adGenericShelves
FROM ADTRAN-GENCHASSIS-MIB
adGenSlotInfoIndex,
adGenSlotAlarmStatus
FROM ADTRAN-GENSLOT-MIB
adGenPortTrapIdentifier
FROM ADTRAN-GENPORT-MIB
adTrapInformSeqNum
FROM ADTRAN-GENTRAPINFORM-MIB
;
-- branch in MIB tree
-- adGenericShelves OBJECT IDENTIFIER ::= { adShared 13 }
-- *******************************************************************************************************
-- ********************************************************************************************************
-- Generic Chassis Traps
-- traps 00 and 01 were mgmtLinkUp and Down. obsolete.
adCtrpCardInserted TRAP-TYPE
ENTERPRISE adGenericShelves
VARIABLES {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex
}
DESCRIPTION
"A card has been inserted into the chassis"
--#TYPE "Warning - A card has been inserted into the chassis"
--#SUMMARY "GENCHASSIS 1001302: Card inserted into chassis;"
--#SUMMARY "detected at chassis: %s, slot: %d"
--#ARGUMENTS { 1, 2 }
--#SEVERITY NORMAL
--#GENERIC 6
--#CATEGORY "Configuration Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= 1001302
adCtrpCardRemoved TRAP-TYPE
ENTERPRISE adGenericShelves
VARIABLES {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex
}
DESCRIPTION
"A card has been removed from the chassis"
--#TYPE "Warning - A card has been removed from the chassis"
--#SUMMARY "GENCHASSIS 1001303: Card removed from chassis;"
--#SUMMARY "detected at chassis: %s, slot: %d"
--#ARGUMENTS { 1, 2 }
--#SEVERITY WARNING
--#GENERIC 6
--#CATEGORY "Configuration Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= 1001303
adCtrpBlownFuse TRAP-TYPE
ENTERPRISE adGenericShelves
VARIABLES {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex
}
DESCRIPTION
"Blown Fuse Alarm is active on module"
--#TYPE "Major - Blown Fuse Alarm is active on module"
--#SUMMARY "GENCHASSIS 1001305: Blown Fuse Alarm active;"
--#SUMMARY "detected at shelf: %s, slot: %d"
--#ARGUMENTS { 1, 2 }
--#SEVERITY MAJOR
--#GENERIC 6
--#CATEGORY "Error Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= 1001305
-- trap 06 and 07 were 6th major alarm traps. obsolete.
adCtrpRmtAlmClear TRAP-TYPE
ENTERPRISE adGenericShelves
VARIABLES {
adTrapInformSeqNum,
sysName
}
DESCRIPTION
"Remote Input Alarm clear"
--#TYPE "Major - Remote Input Alarm clear"
--#SUMMARY "GENCHASSIS 1001308: Remote Input Alarm cleared;"
--#SUMMARY "detected at shelf: %s"
--#ARGUMENTS { 1 }
--#SEVERITY NORMAL
--#GENERIC 6
--#CATEGORY "Error Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= 1001308
adCtrpRmtAlm TRAP-TYPE
ENTERPRISE adGenericShelves
VARIABLES {
adTrapInformSeqNum,
sysName
}
DESCRIPTION
"Remote Input Alarm active"
--#TYPE "Major - Remote Input Alarm active"
--#SUMMARY "GENCHASSIS 1001309: Remote Input Alarm active;"
--#SUMMARY "detected at shelf: %s"
--#ARGUMENTS { 1 }
--#SEVERITY MAJOR
--#GENERIC 6
--#CATEGORY "Error Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= 1001309
adCtrpExt1AlmClear TRAP-TYPE
ENTERPRISE adGenericShelves
VARIABLES {
adTrapInformSeqNum,
sysName
}
DESCRIPTION
"External Input #1 Alarm clear"
--#TYPE "Minor - External Input #1 Alarm clear"
--#SUMMARY "GENCHASSIS 1001310: External Input #1 Alarm cleared;"
--#SUMMARY "detected at shelf: %s"
--#ARGUMENTS { 1 }
--#SEVERITY NORMAL
--#GENERIC 6
--#CATEGORY "Error Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= 1001310
adCtrpExt1Alm TRAP-TYPE
ENTERPRISE adGenericShelves
VARIABLES {
adTrapInformSeqNum,
sysName
}
DESCRIPTION
"External Input #1 Alarm active"
--#TYPE "Minor - External Input #1 Alarm active"
--#SUMMARY "GENCHASSIS 1001311: External Input #1 Alarm active;"
--#SUMMARY "detected at shelf: %s"
--#ARGUMENTS { 1 }
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Error Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= 1001311
adCtrpExt2AlmClear TRAP-TYPE
ENTERPRISE adGenericShelves
VARIABLES {
adTrapInformSeqNum,
sysName
}
DESCRIPTION
"External Input #2 Alarm clear"
--#TYPE "Warning - External Input #2 Alarm clear"
--#SUMMARY "GENCHASSIS 1001312: External Input #2 Alarm cleared;"
--#SUMMARY "detected at shelf: %s"
--#ARGUMENTS { 1 }
--#SEVERITY NORMAL
--#GENERIC 6
--#CATEGORY "Error Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= 1001312
adCtrpExt2Alm TRAP-TYPE
ENTERPRISE adGenericShelves
VARIABLES {
adTrapInformSeqNum,
sysName
}
DESCRIPTION
"External Input #2 Alarm active"
--#TYPE "Warning - External Input #2 Alarm active"
--#SUMMARY "GENCHASSIS 1001313: External Input #2 Alarm active;"
--#SUMMARY "detected at shelf: %s"
--#ARGUMENTS { 1 }
--#SEVERITY WARNING
--#GENERIC 6
--#CATEGORY "Error Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= 1001313
adCtrpBusApwrAlmClear TRAP-TYPE
ENTERPRISE adGenericShelves
VARIABLES {
adTrapInformSeqNum,
sysName
}
DESCRIPTION
"Bus A Power Failure Alarm clear"
--#TYPE "Minor - Bus A Power Failure Alarm clear"
--#SUMMARY "GENCHASSIS 1001314: Bus A Power Failure Alarm cleared;"
--#SUMMARY "detected at shelf: %s"
--#ARGUMENTS { 1 }
--#SEVERITY NORMAL
--#GENERIC 6
--#CATEGORY "Error Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= 1001314
adCtrpBusApowerAlm TRAP-TYPE
ENTERPRISE adGenericShelves
VARIABLES {
adTrapInformSeqNum,
sysName
}
DESCRIPTION
"Bus A Power Failure Alarm active"
--#TYPE "Minor - Bus A Power Failure Alarm active"
--#SUMMARY "GENCHASSIS 1001315: Bus A Power Failure Alarm active;"
--#SUMMARY "detected at shelf: %s"
--#ARGUMENTS { 1 }
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Error Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= 1001315
adCtrpBusBpwrAlmClear TRAP-TYPE
ENTERPRISE adGenericShelves
VARIABLES {
adTrapInformSeqNum,
sysName
}
DESCRIPTION
"Bus B Power Failure Alarm clear"
--#TYPE "Minor - Bus B Power Failure Alarm clear"
--#SUMMARY "GENCHASSIS 1001316: Bus B Power Failure Alarm cleared;"
--#SUMMARY "detected at shelf: %s"
--#ARGUMENTS { 1 }
--#SEVERITY NORMAL
--#GENERIC 6
--#CATEGORY "Error Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= 1001316
adCtrpBusBpowerAlm TRAP-TYPE
ENTERPRISE adGenericShelves
VARIABLES {
adTrapInformSeqNum,
sysName
}
DESCRIPTION
"Bus B Power Failure Alarm active"
--#TYPE "Minor - Bus B Power Failure Alarm active"
--#SUMMARY "GENCHASSIS 1001317: Bus B Power Failure Alarm active;"
--#SUMMARY "detected at shelf: %s"
--#ARGUMENTS { 1 }
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Error Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= 1001317
adCtrpInService TRAP-TYPE
ENTERPRISE adGenericShelves
VARIABLES {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex
}
DESCRIPTION
"A card has entered the In-Service state"
--#TYPE "Minor - A card has entered the In-Service state"
--#SUMMARY "GENCHASSIS 1001318: Card is now In-Service; "
--#SUMMARY "detected at chassis: %s, slot: %d"
--#ARGUMENTS { 1, 2 }
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Error Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= 1001318
adCtrpOutOfService TRAP-TYPE
ENTERPRISE adGenericShelves
VARIABLES {
adTrapInformSeqNum,
sysName,
adGenSlotInfoIndex
}
DESCRIPTION
"A card has entered the Out-Of-Service state"
--#TYPE "Minor - A card has entered the Out-Of-Service state"
--#SUMMARY "GENCHASSIS 1001319: Card is now Out-Of-Service; "
--#SUMMARY "detected at chassis: %s, slot: %d"
--#ARGUMENTS { 1, 2 }
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Error Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= 1001319
END