ADTRAN-GENCHASSISTRAP-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- TITLE: Generic chassis trap MIB
|
|
-- PRODUCT: All chassis type products
|
|
-- VERSION: 1.0
|
|
-- DATE: 00/06/26
|
|
-- AUTHOR: Theresa Chard
|
|
-- SNMP: SNMPv1
|
|
-- MIB ARC: adtran.adShared.adGenericShelves
|
|
-- FILE: genctrap.mib
|
|
|
|
-- HISTORY:
|
|
-- 06/26/00 tgc defined card removal and insertion traps
|
|
-- 08/10/00 pnb insert all generic chassis traps
|
|
-- clarify that link up/link down are mgmt links (AMCP)
|
|
-- change link down cleared to link up
|
|
-- removed blown fuse alarm clear - can't happen
|
|
-- removed unknown card fuse blown - superfluous
|
|
-- 09/28/00 pnb converted trap sequence number to object in genport.mib
|
|
-- since all trap objects were allocated to gentrap.mib.
|
|
-- This changed MO name from adGenChassisSeqNum to
|
|
-- adTrapInformSeqNum
|
|
-- 04/03/01 pnb Removed mgmtup/down link traps, and removed superfluous
|
|
-- varbinds from others. Added prefix to all trap names.
|
|
-- 04/06/01 pnb Removed 6th major alarm traps.
|
|
-- 05/09/01 pnb Add service state traps
|
|
-- 05/10/01 pnb Added comment about previously used OIDs.
|
|
-- 05/10/01 pnb Changed all names to reduce size for HP OpenView limitations
|
|
|
|
|
|
|
|
IMPORTS
|
|
sysName
|
|
FROM RFC1213-MIB
|
|
TRAP-TYPE
|
|
FROM RFC-1215
|
|
adGenericShelves
|
|
FROM ADTRAN-GENCHASSIS-MIB
|
|
adGenSlotInfoIndex,
|
|
adGenSlotAlarmStatus
|
|
FROM ADTRAN-GENSLOT-MIB
|
|
adGenPortTrapIdentifier
|
|
FROM ADTRAN-GENPORT-MIB
|
|
adTrapInformSeqNum
|
|
FROM ADTRAN-GENTRAPINFORM-MIB
|
|
;
|
|
|
|
-- branch in MIB tree
|
|
|
|
-- adGenericShelves OBJECT IDENTIFIER ::= { adShared 13 }
|
|
|
|
|
|
-- *******************************************************************************************************
|
|
|
|
-- ********************************************************************************************************
|
|
|
|
-- Generic Chassis Traps
|
|
|
|
-- traps 00 and 01 were mgmtLinkUp and Down. obsolete.
|
|
|
|
adCtrpCardInserted TRAP-TYPE
|
|
ENTERPRISE adGenericShelves
|
|
VARIABLES {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
DESCRIPTION
|
|
"A card has been inserted into the chassis"
|
|
--#TYPE "Warning - A card has been inserted into the chassis"
|
|
--#SUMMARY "GENCHASSIS 1001302: Card inserted into chassis;"
|
|
--#SUMMARY "detected at chassis: %s, slot: %d"
|
|
--#ARGUMENTS { 1, 2 }
|
|
--#SEVERITY NORMAL
|
|
--#GENERIC 6
|
|
--#CATEGORY "Configuration Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= 1001302
|
|
|
|
|
|
adCtrpCardRemoved TRAP-TYPE
|
|
ENTERPRISE adGenericShelves
|
|
VARIABLES {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
DESCRIPTION
|
|
"A card has been removed from the chassis"
|
|
--#TYPE "Warning - A card has been removed from the chassis"
|
|
--#SUMMARY "GENCHASSIS 1001303: Card removed from chassis;"
|
|
--#SUMMARY "detected at chassis: %s, slot: %d"
|
|
--#ARGUMENTS { 1, 2 }
|
|
--#SEVERITY WARNING
|
|
--#GENERIC 6
|
|
--#CATEGORY "Configuration Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= 1001303
|
|
|
|
adCtrpBlownFuse TRAP-TYPE
|
|
ENTERPRISE adGenericShelves
|
|
VARIABLES {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
DESCRIPTION
|
|
"Blown Fuse Alarm is active on module"
|
|
--#TYPE "Major - Blown Fuse Alarm is active on module"
|
|
--#SUMMARY "GENCHASSIS 1001305: Blown Fuse Alarm active;"
|
|
--#SUMMARY "detected at shelf: %s, slot: %d"
|
|
--#ARGUMENTS { 1, 2 }
|
|
--#SEVERITY MAJOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= 1001305
|
|
|
|
-- trap 06 and 07 were 6th major alarm traps. obsolete.
|
|
|
|
|
|
adCtrpRmtAlmClear TRAP-TYPE
|
|
ENTERPRISE adGenericShelves
|
|
VARIABLES {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
DESCRIPTION
|
|
"Remote Input Alarm clear"
|
|
--#TYPE "Major - Remote Input Alarm clear"
|
|
--#SUMMARY "GENCHASSIS 1001308: Remote Input Alarm cleared;"
|
|
--#SUMMARY "detected at shelf: %s"
|
|
--#ARGUMENTS { 1 }
|
|
--#SEVERITY NORMAL
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= 1001308
|
|
|
|
adCtrpRmtAlm TRAP-TYPE
|
|
ENTERPRISE adGenericShelves
|
|
VARIABLES {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
DESCRIPTION
|
|
"Remote Input Alarm active"
|
|
--#TYPE "Major - Remote Input Alarm active"
|
|
--#SUMMARY "GENCHASSIS 1001309: Remote Input Alarm active;"
|
|
--#SUMMARY "detected at shelf: %s"
|
|
--#ARGUMENTS { 1 }
|
|
--#SEVERITY MAJOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= 1001309
|
|
|
|
adCtrpExt1AlmClear TRAP-TYPE
|
|
ENTERPRISE adGenericShelves
|
|
VARIABLES {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
DESCRIPTION
|
|
"External Input #1 Alarm clear"
|
|
--#TYPE "Minor - External Input #1 Alarm clear"
|
|
--#SUMMARY "GENCHASSIS 1001310: External Input #1 Alarm cleared;"
|
|
--#SUMMARY "detected at shelf: %s"
|
|
--#ARGUMENTS { 1 }
|
|
--#SEVERITY NORMAL
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= 1001310
|
|
|
|
adCtrpExt1Alm TRAP-TYPE
|
|
ENTERPRISE adGenericShelves
|
|
VARIABLES {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
DESCRIPTION
|
|
"External Input #1 Alarm active"
|
|
--#TYPE "Minor - External Input #1 Alarm active"
|
|
--#SUMMARY "GENCHASSIS 1001311: External Input #1 Alarm active;"
|
|
--#SUMMARY "detected at shelf: %s"
|
|
--#ARGUMENTS { 1 }
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= 1001311
|
|
|
|
adCtrpExt2AlmClear TRAP-TYPE
|
|
ENTERPRISE adGenericShelves
|
|
VARIABLES {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
DESCRIPTION
|
|
"External Input #2 Alarm clear"
|
|
--#TYPE "Warning - External Input #2 Alarm clear"
|
|
--#SUMMARY "GENCHASSIS 1001312: External Input #2 Alarm cleared;"
|
|
--#SUMMARY "detected at shelf: %s"
|
|
--#ARGUMENTS { 1 }
|
|
--#SEVERITY NORMAL
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= 1001312
|
|
|
|
adCtrpExt2Alm TRAP-TYPE
|
|
ENTERPRISE adGenericShelves
|
|
VARIABLES {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
DESCRIPTION
|
|
"External Input #2 Alarm active"
|
|
--#TYPE "Warning - External Input #2 Alarm active"
|
|
--#SUMMARY "GENCHASSIS 1001313: External Input #2 Alarm active;"
|
|
--#SUMMARY "detected at shelf: %s"
|
|
--#ARGUMENTS { 1 }
|
|
--#SEVERITY WARNING
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= 1001313
|
|
|
|
adCtrpBusApwrAlmClear TRAP-TYPE
|
|
ENTERPRISE adGenericShelves
|
|
VARIABLES {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
DESCRIPTION
|
|
"Bus A Power Failure Alarm clear"
|
|
--#TYPE "Minor - Bus A Power Failure Alarm clear"
|
|
--#SUMMARY "GENCHASSIS 1001314: Bus A Power Failure Alarm cleared;"
|
|
--#SUMMARY "detected at shelf: %s"
|
|
--#ARGUMENTS { 1 }
|
|
--#SEVERITY NORMAL
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= 1001314
|
|
|
|
adCtrpBusApowerAlm TRAP-TYPE
|
|
ENTERPRISE adGenericShelves
|
|
VARIABLES {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
DESCRIPTION
|
|
"Bus A Power Failure Alarm active"
|
|
--#TYPE "Minor - Bus A Power Failure Alarm active"
|
|
--#SUMMARY "GENCHASSIS 1001315: Bus A Power Failure Alarm active;"
|
|
--#SUMMARY "detected at shelf: %s"
|
|
--#ARGUMENTS { 1 }
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= 1001315
|
|
|
|
adCtrpBusBpwrAlmClear TRAP-TYPE
|
|
ENTERPRISE adGenericShelves
|
|
VARIABLES {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
DESCRIPTION
|
|
"Bus B Power Failure Alarm clear"
|
|
--#TYPE "Minor - Bus B Power Failure Alarm clear"
|
|
--#SUMMARY "GENCHASSIS 1001316: Bus B Power Failure Alarm cleared;"
|
|
--#SUMMARY "detected at shelf: %s"
|
|
--#ARGUMENTS { 1 }
|
|
--#SEVERITY NORMAL
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= 1001316
|
|
|
|
adCtrpBusBpowerAlm TRAP-TYPE
|
|
ENTERPRISE adGenericShelves
|
|
VARIABLES {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
DESCRIPTION
|
|
"Bus B Power Failure Alarm active"
|
|
--#TYPE "Minor - Bus B Power Failure Alarm active"
|
|
--#SUMMARY "GENCHASSIS 1001317: Bus B Power Failure Alarm active;"
|
|
--#SUMMARY "detected at shelf: %s"
|
|
--#ARGUMENTS { 1 }
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= 1001317
|
|
|
|
adCtrpInService TRAP-TYPE
|
|
ENTERPRISE adGenericShelves
|
|
VARIABLES {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
DESCRIPTION
|
|
"A card has entered the In-Service state"
|
|
--#TYPE "Minor - A card has entered the In-Service state"
|
|
--#SUMMARY "GENCHASSIS 1001318: Card is now In-Service; "
|
|
--#SUMMARY "detected at chassis: %s, slot: %d"
|
|
--#ARGUMENTS { 1, 2 }
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= 1001318
|
|
|
|
|
|
adCtrpOutOfService TRAP-TYPE
|
|
ENTERPRISE adGenericShelves
|
|
VARIABLES {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSlotInfoIndex
|
|
}
|
|
DESCRIPTION
|
|
"A card has entered the Out-Of-Service state"
|
|
--#TYPE "Minor - A card has entered the Out-Of-Service state"
|
|
--#SUMMARY "GENCHASSIS 1001319: Card is now Out-Of-Service; "
|
|
--#SUMMARY "detected at chassis: %s, slot: %d"
|
|
--#ARGUMENTS { 1, 2 }
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= 1001319
|
|
|
|
|
|
END
|