799 lines
28 KiB
Plaintext
799 lines
28 KiB
Plaintext
ADTRAN-GEN-SYSTEM-TIMING-MIB
|
|
|
|
-- TITLE: The ADTRAN Generic System MIB
|
|
-- PRODUCT: SYSTEM Level Support
|
|
-- VERSION: 1.0
|
|
-- DATE: 03/02/09
|
|
-- AUTHOR: Larry Deaton/ Andria Dyess
|
|
-- STATUS: PRELIMINARY
|
|
|
|
-- This MIB defines the object identifiers (OIDs) for the
|
|
-- ADTRAN GENERIC SYSTEM TIMING objects
|
|
|
|
-- HISTORY:
|
|
-- 02/16/09 aed Preliminary Draft
|
|
-- 03/02/09 lmd Revised draft after initial design review
|
|
-- 03/25/09 aed Added more provisioning and status OIDs from adTa5kSm.mi2
|
|
-- 04/07/09 jlb Changed the description of adGenSystemTimingInterfaceType to change the return
|
|
-- value from notApplicable to unknown in the event the timing source is not an interface.
|
|
-- 09/02/09 mguo Added a new timingSrc switch trap.
|
|
-- 09/21/09 mguo moved pri/sec source failed alarms from adTA5KSm.mi2 to the mib file.
|
|
-- 04/07/10 mguo Added a new entry to support E1 clock timing.
|
|
-- 05/03/10 Balaji KP:
|
|
-- Added internal(5),holdover(6) options to adGenSystemTimingCurrentSource
|
|
-- when all the clocks are down, system uses holdover if the memory is available otherwise
|
|
-- uses Internal Oscillator clock.
|
|
-- 02/17/11 Rajesh Perumal Added external source provisioning OID - adGenSystemTimingExternalSourceHopCount.
|
|
-- DO NOT MAKE HISTORY COMMENTS HERE!!!! Revision history is now in REVISION/DESCRIPTION clauses below.
|
|
-- ******************************************************************************************
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
|
|
adGenSystemTiming,
|
|
adGenSystemTimingID
|
|
FROM ADTRAN-SHARED-CND-SYSTEM-MIB
|
|
|
|
GenSystemInterfaceType
|
|
FROM ADTRAN-SHARED-CND-SYSTEM-TC-MIB
|
|
|
|
OBJECT-TYPE,
|
|
MODULE-IDENTITY,
|
|
Integer32,
|
|
NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
|
|
sysName
|
|
FROM SNMPv2-MIB
|
|
|
|
ifIndex
|
|
FROM IF-MIB
|
|
|
|
adTrapInformSeqNum
|
|
FROM ADTRAN-GENTRAPINFORM-MIB
|
|
|
|
TEXTUAL-CONVENTION,
|
|
TruthValue
|
|
FROM SNMPv2-TC
|
|
;
|
|
|
|
adGenSystemTimingMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201801090000Z"
|
|
ORGANIZATION "Adtran, Inc."
|
|
CONTACT-INFO
|
|
"CND Tech Support
|
|
Postal: ADTRAN, Inc.
|
|
901 Explorer Blvd.
|
|
Huntsville, AL 35806
|
|
Tel: +1 800 726-8663
|
|
Fax: +1 256 963 6217
|
|
E-mail: support@adtran.com"
|
|
DESCRIPTION
|
|
"This MIB defines the objects for the Generic System Timing MIB."
|
|
|
|
REVISION "201801090000Z"
|
|
DESCRIPTION "- Added support for the VDSL Uplink NTR timing source for the VXP DMT"
|
|
|
|
REVISION "201709290000Z"
|
|
DESCRIPTION "- Added new external source type bitsD5 for clock input to the AdGenExternalSourceType
|
|
And updated the description of adGenSystemTimingExternalSourceType."
|
|
|
|
REVISION "201707250000Z"
|
|
DESCRIPTION "- Added localPortSyncE and fixedPortSyncE to the AdGenTimingSourceSelection."
|
|
|
|
REVISION "201706120000Z"
|
|
DESCRIPTION "- Added adGenSystemTimingProvPortTable and new OID adGenSystemTimingTransmitSSMEnable to it."
|
|
|
|
REVISION "201309090000Z"
|
|
DESCRIPTION "Add adGenSystemTimingSelectionMode, which takes the place of adGenSystemTimingModeRevertive and adGenSystemTimingUseHopCount.
|
|
Also added two new timing source selection options for phy timing."
|
|
|
|
REVISION "201110261100Z"
|
|
DESCRIPTION "Add support for the alarm enables."
|
|
|
|
REVISION "201109020000Z"
|
|
DESCRIPTION "Added OIDs 11-19 under System Timing Status Information for the primary, secondary, and fallback timing sources."
|
|
|
|
REVISION "200903020000Z"
|
|
DESCRIPTION "Created"
|
|
::= { adGenSystemTimingID 1 }
|
|
|
|
adGenSystemTimingProv OBJECT IDENTIFIER ::= {adGenSystemTiming 1}
|
|
adGenSystemTimingStatus OBJECT IDENTIFIER ::= {adGenSystemTiming 2}
|
|
adGenSystemTimingAlarmPrefix OBJECT IDENTIFIER ::= {adGenSystemTiming 3}
|
|
adGenSystemTimingAlarms OBJECT IDENTIFIER ::= {adGenSystemTimingAlarmPrefix 0}
|
|
|
|
|
|
-- ==================================================================================================================
|
|
-- TEXTUAL-CONVENTIONS
|
|
-- ==================================================================================================================
|
|
|
|
AdGenTimingSource ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enumerates the timing sources that may be provisioned for the system."
|
|
SYNTAX INTEGER {
|
|
primaryTimingSource (1),
|
|
secondaryTimingSource (2),
|
|
fallbackTimingSource (3)
|
|
}
|
|
|
|
AdGenTimingSourceSelection ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the available timing source selections in the system."
|
|
SYNTAX INTEGER {
|
|
internal (1),
|
|
externalPrimary (2),
|
|
externalSecondary (3),
|
|
loopA (4),
|
|
loopB (5),
|
|
localPort (6),
|
|
fixedPort (7),
|
|
localPortSyncE (8),
|
|
fixedPortSyncE (9),
|
|
localPortPhy (10),
|
|
fixedPortPhy (11),
|
|
vdslUplinkNTR (12)
|
|
}
|
|
|
|
AdGenExternalSource ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enumerates the available external timing sources in the system."
|
|
SYNTAX INTEGER {
|
|
externalPrimary(1),
|
|
externalSecondary(2)
|
|
}
|
|
|
|
AdGenTimingConfigurationStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the current state of timing configuration in the system."
|
|
SYNTAX INTEGER {
|
|
invalidConfiguration (1),
|
|
incompleteConfiguration (2),
|
|
okConfiguration (3)
|
|
}
|
|
|
|
AdGenExternalSourceType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the type of external timing source."
|
|
SYNTAX INTEGER {
|
|
bitsD4 (1),
|
|
bitsOD (2),
|
|
composite (3),
|
|
composite8kHz (4),
|
|
bitsG704 (5),
|
|
bitsD5 (6)
|
|
}
|
|
|
|
AdGenTimingSourceQuality ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the quality of the external timing source."
|
|
SYNTAX INTEGER {
|
|
stratum1 (1),
|
|
synchronized (2),
|
|
stratum2 (3),
|
|
transmitModeClock (4),
|
|
stratum3e (5),
|
|
stratum3 (6),
|
|
sonetClock (7),
|
|
stratum4or4e (8),
|
|
doNotUseForSync (15)
|
|
}
|
|
|
|
AdGenSystemTimingSourceHealth ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the health of a timing source."
|
|
SYNTAX INTEGER {
|
|
up(1),
|
|
down(2)
|
|
}
|
|
|
|
-- ==================================================================================================================
|
|
-- System Timing Provisioning Table provisions the primary, secondary, and fallback timing sources.
|
|
-- ==================================================================================================================
|
|
|
|
adGenSystemTimingProvTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenSystemTimingProvEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Generic System Timing Provisioning table."
|
|
::= { adGenSystemTimingProv 1 }
|
|
|
|
adGenSystemTimingProvEntry OBJECT-TYPE
|
|
SYNTAX AdGenSystemTimingProvEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in Generic System Timing Table"
|
|
INDEX { adGenSystemTimingSource }
|
|
::= { adGenSystemTimingProvTable 1 }
|
|
|
|
AdGenSystemTimingProvEntry ::=
|
|
SEQUENCE {
|
|
adGenSystemTimingSource
|
|
AdGenTimingSource,
|
|
adGenSystemTimingSelection
|
|
AdGenTimingSourceSelection,
|
|
adGenSystemTimingInterfaceType
|
|
GenSystemInterfaceType,
|
|
adGenSystemTimingShelf
|
|
Integer32,
|
|
adGenSystemTimingSlot
|
|
Integer32,
|
|
adGenSystemTimingPort
|
|
Integer32,
|
|
adGenSystemTimingConfigurationStatus
|
|
AdGenTimingConfigurationStatus
|
|
}
|
|
|
|
adGenSystemTimingSource OBJECT-TYPE
|
|
SYNTAX AdGenTimingSource
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the timing source for this entry: primary, secondary, or fallback."
|
|
::= { adGenSystemTimingProvEntry 1 }
|
|
|
|
adGenSystemTimingSelection OBJECT-TYPE
|
|
SYNTAX AdGenTimingSourceSelection
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The timing source selection"
|
|
::= { adGenSystemTimingProvEntry 2 }
|
|
|
|
adGenSystemTimingInterfaceType OBJECT-TYPE
|
|
SYNTAX GenSystemInterfaceType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns which type of interface is providing timing.
|
|
Returns unknown(1) if adGenSystemTimingSelection
|
|
is internal, externalPrimary or externalSecondary."
|
|
::= { adGenSystemTimingProvEntry 3 }
|
|
|
|
adGenSystemTimingShelf OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The shelf number for the timing source.
|
|
Returns a value of 0 when adGenSystemTimingSelection
|
|
is internal, externalPrimary, or externalSecondary."
|
|
::= { adGenSystemTimingProvEntry 4 }
|
|
|
|
adGenSystemTimingSlot OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The slot number for the timing source.
|
|
Returns a value of 0 when adGenSystemTimingSelection
|
|
is internal, externalPrimary, or externalSecondary.
|
|
Access module slots are 1 - 22.
|
|
SM-A slot is 252.
|
|
SM-B slot is 253."
|
|
::= { adGenSystemTimingProvEntry 5 }
|
|
|
|
adGenSystemTimingPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number for the timing source.
|
|
Returns a value of 0 when adGenSystemTimingSelection
|
|
is internal, externalPrimary, or externalSecondary."
|
|
::= { adGenSystemTimingProvEntry 6 }
|
|
|
|
|
|
adGenSystemTimingConfigurationStatus OBJECT-TYPE
|
|
SYNTAX AdGenTimingConfigurationStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the current configuration status of timing subsystem"
|
|
::= { adGenSystemTimingProvEntry 7 }
|
|
|
|
-- ==================================================================================================================
|
|
-- External Source Provisioning Table provisions the primary and secondary external clock inputs
|
|
-- ==================================================================================================================
|
|
|
|
adGenSystemTimingExternalSourceProvTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenSystemTimingExternalSourceProvEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The System Timing External Source Provisioning Table."
|
|
::= { adGenSystemTimingProv 2 }
|
|
|
|
adGenSystemTimingExternalSourceProvEntry OBJECT-TYPE
|
|
SYNTAX AdGenSystemTimingExternalSourceProvEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the System Timing External Source Provisioning Table"
|
|
INDEX { adGenSystemTimingExternalSourceId }
|
|
::= { adGenSystemTimingExternalSourceProvTable 1 }
|
|
|
|
AdGenSystemTimingExternalSourceProvEntry ::=
|
|
SEQUENCE {
|
|
adGenSystemTimingExternalSourceId
|
|
AdGenExternalSource,
|
|
adGenSystemTimingExternalSourceType
|
|
AdGenExternalSourceType,
|
|
adGenSystemTimingExternalSourceQuality
|
|
AdGenTimingSourceQuality,
|
|
adGenSystemTimingExternalSourcePriority
|
|
INTEGER,
|
|
adGenSystemTimingExternalSourceHopCount
|
|
INTEGER
|
|
}
|
|
|
|
adGenSystemTimingExternalSourceId OBJECT-TYPE
|
|
SYNTAX AdGenExternalSource
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the external timing source (primary or secondary)."
|
|
::= { adGenSystemTimingExternalSourceProvEntry 1 }
|
|
|
|
adGenSystemTimingExternalSourceType OBJECT-TYPE
|
|
SYNTAX AdGenExternalSourceType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Select which type the External clock input should expect.
|
|
If one external timing source type (primary or secondary)
|
|
is set to bits-d5 from default type i.e. bits-d4 then other
|
|
type will be overwritten to bits-d5 and vice versa."
|
|
::= { adGenSystemTimingExternalSourceProvEntry 2 }
|
|
|
|
adGenSystemTimingExternalSourceQuality OBJECT-TYPE
|
|
SYNTAX AdGenTimingSourceQuality
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Select the quality for the external clock."
|
|
::= { adGenSystemTimingExternalSourceProvEntry 3 }
|
|
|
|
adGenSystemTimingExternalSourcePriority OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Select the priority for the external clock.
|
|
Set adGenSystemTimingExternalSourcePriority to 0
|
|
to use the node number as the priority. Override this
|
|
default behavior by setting a value from 1 to 255."
|
|
::= { adGenSystemTimingExternalSourceProvEntry 4 }
|
|
|
|
adGenSystemTimingExternalSourceHopCount OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Select the Hop Count for the external clock.
|
|
The hop count is the number of nodes between a source
|
|
and a destination. The Hop Count takes a value from
|
|
0 to 255."
|
|
::= { adGenSystemTimingExternalSourceProvEntry 5 }
|
|
|
|
|
|
|
|
-- ==================================================================================================================
|
|
-- Additional System Timing Scalars
|
|
-- ==================================================================================================================
|
|
|
|
adGenSystemTimingModeRevertive OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Enabling this allows the clock to fail back to the primary should the primary source's
|
|
health return to normal. Disabled means the clock will remain on the secondary source after
|
|
a failover. This object has been deprecated in favor of adGenSystemTimingSelectionMode."
|
|
::= { adGenSystemTimingProv 3 }
|
|
|
|
adGenSystemTimingForceClockFailover OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
failover (1),
|
|
notavailable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing a value to this will cause the clock source to failover, a get will always return 1"
|
|
::= { adGenSystemTimingProv 4 }
|
|
|
|
adGenSystemTimingUseHopCount OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Enable or disable the hop count in SM timing messages. This object has been deprecated. Set adGenSystemTimingSelectionMode to useHopCount(3)."
|
|
::= {adGenSystemTimingProv 5 }
|
|
|
|
|
|
-- ******************************************************************************************
|
|
-- Alarm Provisioning
|
|
-- ******************************************************************************************
|
|
adGenSystemTimingSrcSwitchAlarmEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"True - alarm is enabled"
|
|
|
|
DEFVAL {true}
|
|
|
|
::= { adGenSystemTimingProv 6 }
|
|
|
|
adGenSystemTimingPriSrcFailAlarmEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"True - alarm is enabled"
|
|
|
|
DEFVAL {true}
|
|
|
|
::= { adGenSystemTimingProv 7 }
|
|
|
|
adGenSystemTimingSecSrcFailAlarmEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"True - alarm is enabled"
|
|
|
|
DEFVAL {true}
|
|
|
|
::= { adGenSystemTimingProv 8 }
|
|
|
|
adGenSystemTimingSelectionMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
revertive(1),
|
|
nonRevertive(2),
|
|
useHopCount(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify how the current timing source will be selected.
|
|
The system will failover to the secondary timing source if the primary source fails.
|
|
When set to revertive(1), the system will revert back when the primary timing source health returns to normal.
|
|
When set to nonRevertive(2), the system will continue to use the secondary timing source.
|
|
When set to useHopCount(3), the system will choose the best timing source based on the hop count in SM timing messages."
|
|
DEFVAL { revertive }
|
|
::= {adGenSystemTimingProv 9 }
|
|
|
|
|
|
-- ==================================================================================================================
|
|
-- System Timing Port Provisioning Table
|
|
-- ==================================================================================================================
|
|
|
|
adGenSystemTimingProvPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenSystemTimingProvPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Generic System Timing Port Provisioning table."
|
|
::= { adGenSystemTimingProv 10 }
|
|
|
|
adGenSystemTimingProvPortEntry OBJECT-TYPE
|
|
SYNTAX AdGenSystemTimingProvPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in Generic System Timing Port Provisioning Table"
|
|
INDEX { ifIndex }
|
|
::= { adGenSystemTimingProvPortTable 1 }
|
|
|
|
AdGenSystemTimingProvPortEntry ::=
|
|
SEQUENCE {
|
|
adGenSystemTimingTransmitSSMEnable INTEGER
|
|
}
|
|
|
|
adGenSystemTimingTransmitSSMEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates if SSM transmission is enabled/disabled on a port."
|
|
|
|
DEFVAL {disable}
|
|
|
|
::= { adGenSystemTimingProvPortEntry 1 }
|
|
|
|
|
|
-- ==================================================================================================================
|
|
-- System Timing Status Information
|
|
-- ==================================================================================================================
|
|
|
|
adGenSystemTimingCurrentSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
primary (1),
|
|
secondary (2),
|
|
fallback (3),
|
|
standby (4),
|
|
internal(5),
|
|
holdover(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Read-Only: Displays which timing source is currently in use by the system"
|
|
::= { adGenSystemTimingStatus 1 }
|
|
|
|
adGenSystemTimingLoopAClockHealth OBJECT-TYPE
|
|
SYNTAX AdGenSystemTimingSourceHealth
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the health of the loop A timing source"
|
|
::= { adGenSystemTimingStatus 2 }
|
|
|
|
adGenSystemTimingLoopBClockHealth OBJECT-TYPE
|
|
SYNTAX AdGenSystemTimingSourceHealth
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the health of the loop B timing source"
|
|
::= { adGenSystemTimingStatus 3 }
|
|
|
|
adGenSystemTimingBitsAClockHealth OBJECT-TYPE
|
|
SYNTAX AdGenSystemTimingSourceHealth
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the health of the bits A timing source"
|
|
::= { adGenSystemTimingStatus 4 }
|
|
|
|
adGenSystemTimingBitsBClockHealth OBJECT-TYPE
|
|
SYNTAX AdGenSystemTimingSourceHealth
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the health of the bits B timing source"
|
|
::= { adGenSystemTimingStatus 5 }
|
|
|
|
adGenSystemTimingPrimaryClockHealth OBJECT-TYPE
|
|
SYNTAX AdGenSystemTimingSourceHealth
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the health of the primary timing source"
|
|
::= { adGenSystemTimingStatus 6 }
|
|
|
|
adGenSystemTimingSecondaryClockHealth OBJECT-TYPE
|
|
SYNTAX AdGenSystemTimingSourceHealth
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the health of the secondary timing source"
|
|
::= { adGenSystemTimingStatus 7 }
|
|
|
|
adGenSystemTimingCurrentHopCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of hops for the current timing source."
|
|
::= { adGenSystemTimingStatus 8 }
|
|
|
|
adGenSystemTimingCurrentTimingSourcePriority OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The priority value for the current timing source."
|
|
::= { adGenSystemTimingStatus 9 }
|
|
|
|
adGenSystemTimingCurrentTimingSourceQuality OBJECT-TYPE
|
|
SYNTAX AdGenTimingSourceQuality
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The quality of the current timing source."
|
|
::= { adGenSystemTimingStatus 10 }
|
|
|
|
adGenSystemTimingPrimaryHopCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of hops for the primary timing source."
|
|
::= { adGenSystemTimingStatus 11 }
|
|
|
|
adGenSystemTimingPrimaryTimingSourcePriority OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The priority value for the primary timing source."
|
|
::= { adGenSystemTimingStatus 12 }
|
|
|
|
adGenSystemTimingPrimaryTimingSourceQuality OBJECT-TYPE
|
|
SYNTAX AdGenTimingSourceQuality
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The quality of the primary timing source."
|
|
::= { adGenSystemTimingStatus 13 }
|
|
|
|
adGenSystemTimingSecondaryHopCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of hops for the secondary timing source."
|
|
::= { adGenSystemTimingStatus 14 }
|
|
|
|
adGenSystemTimingSecondaryTimingSourcePriority OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The priority value for the secondary timing source."
|
|
::= { adGenSystemTimingStatus 15 }
|
|
|
|
adGenSystemTimingSecondaryTimingSourceQuality OBJECT-TYPE
|
|
SYNTAX AdGenTimingSourceQuality
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The quality of the secondary timing source."
|
|
::= { adGenSystemTimingStatus 16 }
|
|
|
|
adGenSystemTimingFallbackHopCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of hops for the fallback timing source."
|
|
::= { adGenSystemTimingStatus 17 }
|
|
|
|
adGenSystemTimingFallbackTimingSourcePriority OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The priority value for the fallback timing source."
|
|
::= { adGenSystemTimingStatus 18 }
|
|
|
|
adGenSystemTimingFallbackTimingSourceQuality OBJECT-TYPE
|
|
SYNTAX AdGenTimingSourceQuality
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The quality of the fallback timing source."
|
|
::= { adGenSystemTimingStatus 19 }
|
|
|
|
|
|
|
|
|
|
-- -------------------------------------
|
|
-- System Timing Alarms
|
|
-- -------------------------------------
|
|
|
|
adGenSystemTimingSrcSwitch NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName,
|
|
adGenSystemTimingCurrentSource
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the system timing source has occured a protection switch."
|
|
|
|
--#TYPE "Status - TimingSrc Switch"
|
|
--#SUMMARY "TA5000 system timing: Timing Source Switch"
|
|
--#SUMMARY "Shelf: %s curSrc: %d"
|
|
--#ARGUMENTS {1 ,2}
|
|
--#SEVERITY WARNING
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adGenSystemTimingAlarms 1 }
|
|
|
|
adGenSystemTimingPriSrcClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the primary timing source alarm has cleared"
|
|
|
|
--#TYPE "Status - Primary Timing Src Alarm Clear"
|
|
--#SUMMARY "TA5000 system timing: Timing Source Cleared on"
|
|
--#SUMMARY "Shelf: %s"
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adGenSystemTimingAlarms 2 }
|
|
|
|
adGenSystemTimingPriSrcFail NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the primary timing source has failed"
|
|
|
|
--#TYPE "Status - Primary Timing Src Alarm Active"
|
|
--#SUMMARY "TA5000 system timing: Timing Source Failure on"
|
|
--#SUMMARY "Shelf: %s"
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adGenSystemTimingAlarms 3 }
|
|
|
|
adGenSystemTimingSecSrcClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the secondary timing source alarm has cleared"
|
|
|
|
--#TYPE "Status - Secondary Timing Src Alarm Clear"
|
|
--#SUMMARY "TA5000 system timing: Timing Source Cleared on"
|
|
--#SUMMARY "Shelf: %s"
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adGenSystemTimingAlarms 4 }
|
|
|
|
adGenSystemTimingSecSrcFail NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
adTrapInformSeqNum,
|
|
sysName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the secondary timing source has failed"
|
|
|
|
--#TYPE "Status - Secondary Timing Src Alarm Active"
|
|
--#SUMMARY "TA5000 system timing: Timing Source Failure on"
|
|
--#SUMMARY "Shelf: %s"
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY MINOR
|
|
--#GENERIC 6
|
|
--#CATEGORY "Error Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adGenSystemTimingAlarms 5 }
|
|
|
|
|
|
END
|
|
|