ADTRAN-GEN-SYSTEM-TIMING-MIB
-- TITLE: The ADTRAN Generic System MIB
-- PRODUCT: SYSTEM Level Support
-- VERSION: 1.0
-- DATE: 03/02/09
-- AUTHOR: Larry Deaton/ Andria Dyess
-- STATUS: PRELIMINARY
-- This MIB defines the object identifiers (OIDs) for the
-- ADTRAN GENERIC SYSTEM TIMING objects
-- HISTORY:
-- 02/16/09 aed Preliminary Draft
-- 03/02/09 lmd Revised draft after initial design review
-- 03/25/09 aed Added more provisioning and status OIDs from adTa5kSm.mi2
-- 04/07/09 jlb Changed the description of adGenSystemTimingInterfaceType to change the return
-- value from notApplicable to unknown in the event the timing source is not an interface.
-- 09/02/09 mguo Added a new timingSrc switch trap.
-- 09/21/09 mguo moved pri/sec source failed alarms from adTA5KSm.mi2 to the mib file.
-- 04/07/10 mguo Added a new entry to support E1 clock timing.
-- 05/03/10 Balaji KP:
-- Added internal(5),holdover(6) options to adGenSystemTimingCurrentSource
-- when all the clocks are down, system uses holdover if the memory is available otherwise
-- uses Internal Oscillator clock.
-- 02/17/11 Rajesh Perumal Added external source provisioning OID - adGenSystemTimingExternalSourceHopCount.
-- DO NOT MAKE HISTORY COMMENTS HERE!!!! Revision history is now in REVISION/DESCRIPTION clauses below.
-- ******************************************************************************************
DEFINITIONS ::= BEGIN
IMPORTS
adGenSystemTiming,
adGenSystemTimingID
FROM ADTRAN-SHARED-CND-SYSTEM-MIB
GenSystemInterfaceType
FROM ADTRAN-SHARED-CND-SYSTEM-TC-MIB
OBJECT-TYPE,
MODULE-IDENTITY,
Integer32,
NOTIFICATION-TYPE
FROM SNMPv2-SMI
sysName
FROM SNMPv2-MIB
ifIndex
FROM IF-MIB
adTrapInformSeqNum
FROM ADTRAN-GENTRAPINFORM-MIB
TEXTUAL-CONVENTION,
TruthValue
FROM SNMPv2-TC
;
adGenSystemTimingMIB MODULE-IDENTITY
LAST-UPDATED "201801090000Z"
ORGANIZATION "Adtran, Inc."
CONTACT-INFO
"CND Tech Support
Postal: ADTRAN, Inc.
901 Explorer Blvd.
Huntsville, AL 35806
Tel: +1 800 726-8663
Fax: +1 256 963 6217
E-mail: support@adtran.com"
DESCRIPTION
"This MIB defines the objects for the Generic System Timing MIB."
REVISION "201801090000Z"
DESCRIPTION "- Added support for the VDSL Uplink NTR timing source for the VXP DMT"
REVISION "201709290000Z"
DESCRIPTION "- Added new external source type bitsD5 for clock input to the AdGenExternalSourceType
And updated the description of adGenSystemTimingExternalSourceType."
REVISION "201707250000Z"
DESCRIPTION "- Added localPortSyncE and fixedPortSyncE to the AdGenTimingSourceSelection."
REVISION "201706120000Z"
DESCRIPTION "- Added adGenSystemTimingProvPortTable and new OID adGenSystemTimingTransmitSSMEnable to it."
REVISION "201309090000Z"
DESCRIPTION "Add adGenSystemTimingSelectionMode, which takes the place of adGenSystemTimingModeRevertive and adGenSystemTimingUseHopCount.
Also added two new timing source selection options for phy timing."
REVISION "201110261100Z"
DESCRIPTION "Add support for the alarm enables."
REVISION "201109020000Z"
DESCRIPTION "Added OIDs 11-19 under System Timing Status Information for the primary, secondary, and fallback timing sources."
REVISION "200903020000Z"
DESCRIPTION "Created"
::= { adGenSystemTimingID 1 }
adGenSystemTimingProv OBJECT IDENTIFIER ::= {adGenSystemTiming 1}
adGenSystemTimingStatus OBJECT IDENTIFIER ::= {adGenSystemTiming 2}
adGenSystemTimingAlarmPrefix OBJECT IDENTIFIER ::= {adGenSystemTiming 3}
adGenSystemTimingAlarms OBJECT IDENTIFIER ::= {adGenSystemTimingAlarmPrefix 0}
-- ==================================================================================================================
-- TEXTUAL-CONVENTIONS
-- ==================================================================================================================
AdGenTimingSource ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Enumerates the timing sources that may be provisioned for the system."
SYNTAX INTEGER {
primaryTimingSource (1),
secondaryTimingSource (2),
fallbackTimingSource (3)
}
AdGenTimingSourceSelection ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Specifies the available timing source selections in the system."
SYNTAX INTEGER {
internal (1),
externalPrimary (2),
externalSecondary (3),
loopA (4),
loopB (5),
localPort (6),
fixedPort (7),
localPortSyncE (8),
fixedPortSyncE (9),
localPortPhy (10),
fixedPortPhy (11),
vdslUplinkNTR (12)
}
AdGenExternalSource ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Enumerates the available external timing sources in the system."
SYNTAX INTEGER {
externalPrimary(1),
externalSecondary(2)
}
AdGenTimingConfigurationStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Specifies the current state of timing configuration in the system."
SYNTAX INTEGER {
invalidConfiguration (1),
incompleteConfiguration (2),
okConfiguration (3)
}
AdGenExternalSourceType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Specifies the type of external timing source."
SYNTAX INTEGER {
bitsD4 (1),
bitsOD (2),
composite (3),
composite8kHz (4),
bitsG704 (5),
bitsD5 (6)
}
AdGenTimingSourceQuality ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Specifies the quality of the external timing source."
SYNTAX INTEGER {
stratum1 (1),
synchronized (2),
stratum2 (3),
transmitModeClock (4),
stratum3e (5),
stratum3 (6),
sonetClock (7),
stratum4or4e (8),
doNotUseForSync (15)
}
AdGenSystemTimingSourceHealth ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Specifies the health of a timing source."
SYNTAX INTEGER {
up(1),
down(2)
}
-- ==================================================================================================================
-- System Timing Provisioning Table provisions the primary, secondary, and fallback timing sources.
-- ==================================================================================================================
adGenSystemTimingProvTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenSystemTimingProvEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Generic System Timing Provisioning table."
::= { adGenSystemTimingProv 1 }
adGenSystemTimingProvEntry OBJECT-TYPE
SYNTAX AdGenSystemTimingProvEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in Generic System Timing Table"
INDEX { adGenSystemTimingSource }
::= { adGenSystemTimingProvTable 1 }
AdGenSystemTimingProvEntry ::=
SEQUENCE {
adGenSystemTimingSource
AdGenTimingSource,
adGenSystemTimingSelection
AdGenTimingSourceSelection,
adGenSystemTimingInterfaceType
GenSystemInterfaceType,
adGenSystemTimingShelf
Integer32,
adGenSystemTimingSlot
Integer32,
adGenSystemTimingPort
Integer32,
adGenSystemTimingConfigurationStatus
AdGenTimingConfigurationStatus
}
adGenSystemTimingSource OBJECT-TYPE
SYNTAX AdGenTimingSource
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the timing source for this entry: primary, secondary, or fallback."
::= { adGenSystemTimingProvEntry 1 }
adGenSystemTimingSelection OBJECT-TYPE
SYNTAX AdGenTimingSourceSelection
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The timing source selection"
::= { adGenSystemTimingProvEntry 2 }
adGenSystemTimingInterfaceType OBJECT-TYPE
SYNTAX GenSystemInterfaceType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Returns which type of interface is providing timing.
Returns unknown(1) if adGenSystemTimingSelection
is internal, externalPrimary or externalSecondary."
::= { adGenSystemTimingProvEntry 3 }
adGenSystemTimingShelf OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The shelf number for the timing source.
Returns a value of 0 when adGenSystemTimingSelection
is internal, externalPrimary, or externalSecondary."
::= { adGenSystemTimingProvEntry 4 }
adGenSystemTimingSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The slot number for the timing source.
Returns a value of 0 when adGenSystemTimingSelection
is internal, externalPrimary, or externalSecondary.
Access module slots are 1 - 22.
SM-A slot is 252.
SM-B slot is 253."
::= { adGenSystemTimingProvEntry 5 }
adGenSystemTimingPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port number for the timing source.
Returns a value of 0 when adGenSystemTimingSelection
is internal, externalPrimary, or externalSecondary."
::= { adGenSystemTimingProvEntry 6 }
adGenSystemTimingConfigurationStatus OBJECT-TYPE
SYNTAX AdGenTimingConfigurationStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the current configuration status of timing subsystem"
::= { adGenSystemTimingProvEntry 7 }
-- ==================================================================================================================
-- External Source Provisioning Table provisions the primary and secondary external clock inputs
-- ==================================================================================================================
adGenSystemTimingExternalSourceProvTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenSystemTimingExternalSourceProvEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The System Timing External Source Provisioning Table."
::= { adGenSystemTimingProv 2 }
adGenSystemTimingExternalSourceProvEntry OBJECT-TYPE
SYNTAX AdGenSystemTimingExternalSourceProvEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the System Timing External Source Provisioning Table"
INDEX { adGenSystemTimingExternalSourceId }
::= { adGenSystemTimingExternalSourceProvTable 1 }
AdGenSystemTimingExternalSourceProvEntry ::=
SEQUENCE {
adGenSystemTimingExternalSourceId
AdGenExternalSource,
adGenSystemTimingExternalSourceType
AdGenExternalSourceType,
adGenSystemTimingExternalSourceQuality
AdGenTimingSourceQuality,
adGenSystemTimingExternalSourcePriority
INTEGER,
adGenSystemTimingExternalSourceHopCount
INTEGER
}
adGenSystemTimingExternalSourceId OBJECT-TYPE
SYNTAX AdGenExternalSource
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the external timing source (primary or secondary)."
::= { adGenSystemTimingExternalSourceProvEntry 1 }
adGenSystemTimingExternalSourceType OBJECT-TYPE
SYNTAX AdGenExternalSourceType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select which type the External clock input should expect.
If one external timing source type (primary or secondary)
is set to bits-d5 from default type i.e. bits-d4 then other
type will be overwritten to bits-d5 and vice versa."
::= { adGenSystemTimingExternalSourceProvEntry 2 }
adGenSystemTimingExternalSourceQuality OBJECT-TYPE
SYNTAX AdGenTimingSourceQuality
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select the quality for the external clock."
::= { adGenSystemTimingExternalSourceProvEntry 3 }
adGenSystemTimingExternalSourcePriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select the priority for the external clock.
Set adGenSystemTimingExternalSourcePriority to 0
to use the node number as the priority. Override this
default behavior by setting a value from 1 to 255."
::= { adGenSystemTimingExternalSourceProvEntry 4 }
adGenSystemTimingExternalSourceHopCount OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select the Hop Count for the external clock.
The hop count is the number of nodes between a source
and a destination. The Hop Count takes a value from
0 to 255."
::= { adGenSystemTimingExternalSourceProvEntry 5 }
-- ==================================================================================================================
-- Additional System Timing Scalars
-- ==================================================================================================================
adGenSystemTimingModeRevertive OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Enabling this allows the clock to fail back to the primary should the primary source's
health return to normal. Disabled means the clock will remain on the secondary source after
a failover. This object has been deprecated in favor of adGenSystemTimingSelectionMode."
::= { adGenSystemTimingProv 3 }
adGenSystemTimingForceClockFailover OBJECT-TYPE
SYNTAX INTEGER {
failover (1),
notavailable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Writing a value to this will cause the clock source to failover, a get will always return 1"
::= { adGenSystemTimingProv 4 }
adGenSystemTimingUseHopCount OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Enable or disable the hop count in SM timing messages. This object has been deprecated. Set adGenSystemTimingSelectionMode to useHopCount(3)."
::= {adGenSystemTimingProv 5 }
-- ******************************************************************************************
-- Alarm Provisioning
-- ******************************************************************************************
adGenSystemTimingSrcSwitchAlarmEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"True - alarm is enabled"
DEFVAL {true}
::= { adGenSystemTimingProv 6 }
adGenSystemTimingPriSrcFailAlarmEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"True - alarm is enabled"
DEFVAL {true}
::= { adGenSystemTimingProv 7 }
adGenSystemTimingSecSrcFailAlarmEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"True - alarm is enabled"
DEFVAL {true}
::= { adGenSystemTimingProv 8 }
adGenSystemTimingSelectionMode OBJECT-TYPE
SYNTAX INTEGER {
revertive(1),
nonRevertive(2),
useHopCount(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify how the current timing source will be selected.
The system will failover to the secondary timing source if the primary source fails.
When set to revertive(1), the system will revert back when the primary timing source health returns to normal.
When set to nonRevertive(2), the system will continue to use the secondary timing source.
When set to useHopCount(3), the system will choose the best timing source based on the hop count in SM timing messages."
DEFVAL { revertive }
::= {adGenSystemTimingProv 9 }
-- ==================================================================================================================
-- System Timing Port Provisioning Table
-- ==================================================================================================================
adGenSystemTimingProvPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenSystemTimingProvPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Generic System Timing Port Provisioning table."
::= { adGenSystemTimingProv 10 }
adGenSystemTimingProvPortEntry OBJECT-TYPE
SYNTAX AdGenSystemTimingProvPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in Generic System Timing Port Provisioning Table"
INDEX { ifIndex }
::= { adGenSystemTimingProvPortTable 1 }
AdGenSystemTimingProvPortEntry ::=
SEQUENCE {
adGenSystemTimingTransmitSSMEnable INTEGER
}
adGenSystemTimingTransmitSSMEnable OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if SSM transmission is enabled/disabled on a port."
DEFVAL {disable}
::= { adGenSystemTimingProvPortEntry 1 }
-- ==================================================================================================================
-- System Timing Status Information
-- ==================================================================================================================
adGenSystemTimingCurrentSource OBJECT-TYPE
SYNTAX INTEGER {
primary (1),
secondary (2),
fallback (3),
standby (4),
internal(5),
holdover(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Read-Only: Displays which timing source is currently in use by the system"
::= { adGenSystemTimingStatus 1 }
adGenSystemTimingLoopAClockHealth OBJECT-TYPE
SYNTAX AdGenSystemTimingSourceHealth
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the health of the loop A timing source"
::= { adGenSystemTimingStatus 2 }
adGenSystemTimingLoopBClockHealth OBJECT-TYPE
SYNTAX AdGenSystemTimingSourceHealth
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the health of the loop B timing source"
::= { adGenSystemTimingStatus 3 }
adGenSystemTimingBitsAClockHealth OBJECT-TYPE
SYNTAX AdGenSystemTimingSourceHealth
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the health of the bits A timing source"
::= { adGenSystemTimingStatus 4 }
adGenSystemTimingBitsBClockHealth OBJECT-TYPE
SYNTAX AdGenSystemTimingSourceHealth
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the health of the bits B timing source"
::= { adGenSystemTimingStatus 5 }
adGenSystemTimingPrimaryClockHealth OBJECT-TYPE
SYNTAX AdGenSystemTimingSourceHealth
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the health of the primary timing source"
::= { adGenSystemTimingStatus 6 }
adGenSystemTimingSecondaryClockHealth OBJECT-TYPE
SYNTAX AdGenSystemTimingSourceHealth
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the health of the secondary timing source"
::= { adGenSystemTimingStatus 7 }
adGenSystemTimingCurrentHopCount OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of hops for the current timing source."
::= { adGenSystemTimingStatus 8 }
adGenSystemTimingCurrentTimingSourcePriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The priority value for the current timing source."
::= { adGenSystemTimingStatus 9 }
adGenSystemTimingCurrentTimingSourceQuality OBJECT-TYPE
SYNTAX AdGenTimingSourceQuality
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The quality of the current timing source."
::= { adGenSystemTimingStatus 10 }
adGenSystemTimingPrimaryHopCount OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of hops for the primary timing source."
::= { adGenSystemTimingStatus 11 }
adGenSystemTimingPrimaryTimingSourcePriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The priority value for the primary timing source."
::= { adGenSystemTimingStatus 12 }
adGenSystemTimingPrimaryTimingSourceQuality OBJECT-TYPE
SYNTAX AdGenTimingSourceQuality
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The quality of the primary timing source."
::= { adGenSystemTimingStatus 13 }
adGenSystemTimingSecondaryHopCount OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of hops for the secondary timing source."
::= { adGenSystemTimingStatus 14 }
adGenSystemTimingSecondaryTimingSourcePriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The priority value for the secondary timing source."
::= { adGenSystemTimingStatus 15 }
adGenSystemTimingSecondaryTimingSourceQuality OBJECT-TYPE
SYNTAX AdGenTimingSourceQuality
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The quality of the secondary timing source."
::= { adGenSystemTimingStatus 16 }
adGenSystemTimingFallbackHopCount OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of hops for the fallback timing source."
::= { adGenSystemTimingStatus 17 }
adGenSystemTimingFallbackTimingSourcePriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The priority value for the fallback timing source."
::= { adGenSystemTimingStatus 18 }
adGenSystemTimingFallbackTimingSourceQuality OBJECT-TYPE
SYNTAX AdGenTimingSourceQuality
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The quality of the fallback timing source."
::= { adGenSystemTimingStatus 19 }
-- -------------------------------------
-- System Timing Alarms
-- -------------------------------------
adGenSystemTimingSrcSwitch NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName,
adGenSystemTimingCurrentSource
}
STATUS current
DESCRIPTION
"Indicates that the system timing source has occured a protection switch."
--#TYPE "Status - TimingSrc Switch"
--#SUMMARY "TA5000 system timing: Timing Source Switch"
--#SUMMARY "Shelf: %s curSrc: %d"
--#ARGUMENTS {1 ,2}
--#SEVERITY WARNING
--#GENERIC 6
--#CATEGORY "Error Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { adGenSystemTimingAlarms 1 }
adGenSystemTimingPriSrcClear NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName
}
STATUS current
DESCRIPTION
"Indicates that the primary timing source alarm has cleared"
--#TYPE "Status - Primary Timing Src Alarm Clear"
--#SUMMARY "TA5000 system timing: Timing Source Cleared on"
--#SUMMARY "Shelf: %s"
--#ARGUMENTS {1}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Error Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { adGenSystemTimingAlarms 2 }
adGenSystemTimingPriSrcFail NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName
}
STATUS current
DESCRIPTION
"Indicates that the primary timing source has failed"
--#TYPE "Status - Primary Timing Src Alarm Active"
--#SUMMARY "TA5000 system timing: Timing Source Failure on"
--#SUMMARY "Shelf: %s"
--#ARGUMENTS {1}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Error Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { adGenSystemTimingAlarms 3 }
adGenSystemTimingSecSrcClear NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName
}
STATUS current
DESCRIPTION
"Indicates that the secondary timing source alarm has cleared"
--#TYPE "Status - Secondary Timing Src Alarm Clear"
--#SUMMARY "TA5000 system timing: Timing Source Cleared on"
--#SUMMARY "Shelf: %s"
--#ARGUMENTS {1}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Error Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { adGenSystemTimingAlarms 4 }
adGenSystemTimingSecSrcFail NOTIFICATION-TYPE
OBJECTS {
adTrapInformSeqNum,
sysName
}
STATUS current
DESCRIPTION
"Indicates that the secondary timing source has failed"
--#TYPE "Status - Secondary Timing Src Alarm Active"
--#SUMMARY "TA5000 system timing: Timing Source Failure on"
--#SUMMARY "Shelf: %s"
--#ARGUMENTS {1}
--#SEVERITY MINOR
--#GENERIC 6
--#CATEGORY "Error Events"
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { adGenSystemTimingAlarms 5 }
END