Observium_CE/mibs/a3com/C-PRODUCT-CBR-MIB

660 lines
23 KiB
Plaintext

C-PRODUCT-CBR-MIB DEFINITIONS ::= BEGIN
IMPORTS
cbr FROM C-PRODUCT-GROUP-MIB
portSlot,
portNumber,
vcpSideId,
TimeAndDate FROM C-PRODUCT-BASE-MIB
Counter FROM RFC1155-SMI
OBJECT-TYPE FROM RFC-1212;
-- Data Types
-- CBR groups
cbrDS1E1CardConfig OBJECT IDENTIFIER ::= {cbr 1}
cbrDS1E1PortConfig OBJECT IDENTIFIER ::= {cbr 2}
cbrDS1E1VcConfig OBJECT IDENTIFIER ::= {cbr 3}
cbrDS1E1ATMStats OBJECT IDENTIFIER ::= {cbr 4}
cbrV35PortConfig OBJECT IDENTIFIER ::= {cbr 5}
cbrDS1E1NewVcConfig OBJECT IDENTIFIER ::= {cbr 6}
cbrDS1E1NewATMStats OBJECT IDENTIFIER ::= {cbr 7}
-- CBR Card Configuration Group (cbrDS1E1CardConfig)
cbrDS1E1CardConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF CbrDS1E1CardEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This object contains the CBR specific card Configuration table.
There is one cbrDS1E1CardConfEntry associated for each provisioned
CBR interface within the shelf. This table uses portSlot as an index
which is defined in the portBaseTable of the C-PRODUCT BASE MIB.
This index value uniquely identifies the CBR interface to which this
entry is applicable."
::= {cbrDS1E1CardConfig 1}
cbrDS1E1CardConfEntry OBJECT-TYPE
SYNTAX CbrDS1E1CardEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the CBR specific card Configuration table."
INDEX { portSlot }
::= {cbrDS1E1CardConfTable 1}
CbrDS1E1CardEntry ::=
SEQUENCE {
cbrDS1E1CardRefPort
INTEGER
}
cbrDS1E1CardRefPort OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates which port the receive clock may be selected as
the system reference clock source. The value range starts at 1 and the
maximum value is dependent upon the total number of physical ports on
the specified CBR interface. Four and eight port CBR intefaces are
supported. An error is returned if this object is set outside the
range of the specified physical card interface. In addition, an error
is returned if this slot has been selected as the system reference
clock and an attempt is made to change to a port not in-service.
The default value is port 1 (1)."
DEFVAL { 1 }
::= {cbrDS1E1CardConfEntry 1}
-- CBR Port Configuration Group (cbrDS1E1PortConfig)
cbrDS1E1PortConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF CbrDS1E1PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This object contains the CBR specific port Configuration table.
There is one cbrDS1E1PortConfEntry associated for each provisioned
CBR port interface within the shelf. This table uses portSlot and
portNumber as an index which is defined in the portBaseTable of the
C-PRODUCT BASE MIB. This index value uniquely identifies the CBR port
interface to which this entry is applicable."
::= {cbrDS1E1PortConfig 1}
cbrDS1E1PortConfEntry OBJECT-TYPE
SYNTAX CbrDS1E1PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the CBR specific port Configuration table."
INDEX { portSlot, portNumber }
::= { cbrDS1E1PortConfTable 1 }
CbrDS1E1PortEntry ::=
SEQUENCE {
cbrDS1E1PortConfLBO
INTEGER,
cbrDS1E1PortConfLineCode
INTEGER,
cbrDS1E1PortConfPortMode
INTEGER,
cbrDS1E1PortConfFraming
INTEGER,
cbrDS1E1PortConfTiming
INTEGER,
cbrDS1E1PortConfSignaling
INTEGER,
cbrDS1E1PortConfCRC-4
INTEGER,
cbrDS1E1PortConfDS0Channels
INTEGER,
cbrDS1E1PortConfLoopBackType
INTEGER
}
cbrDS1E1PortConfLBO OBJECT-TYPE
SYNTAX INTEGER {
dsx-0-110ft(1),
dsx-110-220ft(2),
dsx-220-330ft(3),
dsx-330-440ft(4),
dsx-440-550ft(5),
dsx-550-600ft(6),
dsx-GT-600ft(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is applicable to a T1-DSX CBR interface ONLY and
indicates the associated Line Build Out configuration for the
designated port. An error is returned if an access is attempted on
a physical interface other than a T1-DSX port interface. The default
value is 330 to 440 feet (4)."
DEFVAL { dsx-330-440ft }
::= {cbrDS1E1PortConfEntry 1}
cbrDS1E1PortConfLineCode OBJECT-TYPE
SYNTAX INTEGER {
ami(1),
t1-B8ZS(2),
e1-HDB3(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates the zero code suppression technique
configured to the specified T1/E1 port interface. The bipolar
with 8 zero substitution (B8ZS) technique is applicable to T1
interfaces ONLY. The High Density Binary Three (HDB3) is
applicable to E1 interfaces ONLY."
::= {cbrDS1E1PortConfEntry 2}
cbrDS1E1PortConfPortMode OBJECT-TYPE
SYNTAX INTEGER {
unstructured(1),
struct-voice(2),
struct-data(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates the type of service configured to the
specified T1/E1 port interface. Unstructured allows the
application to utilize the entire available bandwidth at a
bit rate of 1.544 Mb/s for T1 or 2.048 Mb/s for E1. T1/E1 Framing
is optional in this service mode. Structured service provides Nx64
kbit/s capability where N ranges between 1 and the maximum number of
available DS0 channels. Struct-Voice passes traffic with signaling
informaion enabled. Struct-Data passes traffic with signaling
information disabled. Changing the mode configuration will cause
the following parameters to be changed.
. framing timing signaling crc-4
. ------- ------ --------- -----
. T1 unstructured unframed N/A N/A N/A
. struct data ESF loop* N/A N/A
. struct voice ESF loop* N/A N/A
. E1 unstructured unframed N/A disable disable
. struct data single loop* disable disable
. struct voice multi loop* enable enable
* timing is converted to loop timing only if timing is previously
. configured to be in SRTS or adaptive timing modes
NOTE: Changing this object to a different mode will cause all
previously associated VCC's to be deleted. The default value for
this object is unstructured (1)."
DEFVAL { unstructured }
::= { cbrDS1E1PortConfEntry 3 }
cbrDS1E1PortConfFraming OBJECT-TYPE
SYNTAX INTEGER {
unframed(1),
t1-D4(2),
t1-ESF(3),
e1-single-frame(4),
e1-multi-frame(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates the type of frame organization configured for
the specified T1/E1 port interface. D4 and ESF frame organizations
apply to T1 interfaces ONLY. Single-frame and multi-frame organizations
pertain to E1 interfaces ONLY. An error is returned if a set is
applied to an inappropriate cardtype (eg. T1-D4 is applied to an E1
cardtype). Unframed is not a valid configuration in a structured mode.
The E1 interface will not allow framing to be changed in structured
voice mode. Changing the framing configuration for an E1 interface
will cause the following parameters to be changed in unstructured
and structured data modes.
. signaling crc-4
. --------- -----
. E1 unframed disable disable
. single-frame disable* disable
. multi-frame enable* enable
* signaling is automatically changed in unstructured mode only
The default value is unframed (1)."
DEFVAL { unframed }
::= { cbrDS1E1PortConfEntry 4 }
cbrDS1E1PortConfTiming OBJECT-TYPE
SYNTAX INTEGER {
system(1),
loop(2),
srts(3),
adaptive(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates the type of input clock service configured for
the specified T1/E1 port interface. Synchronous Residual Time Stamp
(SRTS) and Adaptive timing modes are ONLY available in unstructured
mode. System configures the port interface to use the system reference
clock within the shelf as a reference for transmitting. Loop uses
the input port Rx clock as the timing source. An error is returned if
an access is attempted to set this object in an inappropriate port
mode (eg. SRTS is applied in structured voice mode). The default value
is adaptive (4)."
DEFVAL { adaptive }
::= { cbrDS1E1PortConfEntry 5 }
cbrDS1E1PortConfSignaling OBJECT-TYPE
SYNTAX INTEGER {
no-signaling(1),
e1-CAS(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is applicable to E1 interfaces ONLY and indicates if
signaling information is enabled or disabled. Signaling information
is always disabled in E1 single-frame or unframed mode. Signaling
information is always enabled in structured voice multi-frame mode.
An error is returned if a set is applied to an inappropriate cardtype
(eg. E1-CAS is applied to a T1 cardtype). In addition, the crc-4
configuration object is automatically disabled if the E1 interface is
in unstructured multi-frame mode and signaling is disabled.
NOTE: This object can ONLY be changed in E1 unstructured multi-frame
mode. The default value is no-signaling (1)."
DEFVAL { no-signaling }
::= { cbrDS1E1PortConfEntry 6 }
cbrDS1E1PortConfCRC-4 OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is applicable to E1 interfaces ONLY and indicates if
CRC-4 information is enabled or disabled. CRC-4 information is
always disabled in E1 single-frame or unframed mode. CRC-4
information is always enabled in multi-frame mode with signaling
disabled. NOTE: This object can ONLY be modified in E1 CAS multi-frame
mode. The default value is disabled (1)."
DEFVAL { disabled }
::= { cbrDS1E1PortConfEntry 7 }
cbrDS1E1PortConfDS0Channels OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the associated DS0's which have been assigned
to the specified physical port interface. All available DS0 channels
are automatically allocated in unstructured mode. In structured mode,
the DS0 channels are bit-coded with each bit representing one DS0
channel. The following are some examples:
Value Representation
0x00000002 DS0-1 has been allocated to this port
0x000007f0 DS0-4 to DS0-10 have been allocated to this port
0x00027004 DS0-2, DS0-12 to DS0-14, DS0-17 have been allocated
In E1 structured voice mode, the bit fields correspond to telephone
channels and are automatically mapped to it's associated DS0
channel. Valid telephone channels range from 1 to 30.
"
::= { cbrDS1E1PortConfEntry 8 }
cbrDS1E1PortConfLoopBackType OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
network-line(2),
local-card(3),
network-card(4),
no-response(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates the type of loopback configured for the
specified T1/E1 port interface. Network-line (2) redirects incoming
remote traffic back into the network interface at the external edge of
the card interface. Network-card (4) regenerates framing information
prior to redirecting incoming remote traffic back into the network
interface. Local-card (3) redirects local incoming traffic back into
the local system. The default value is no-loopback (1)."
DEFVAL { no-loopback }
::= { cbrDS1E1PortConfEntry 9 }
-- This definition is good only for Lodi 1.4 & 1.5, Use new implementation
-- If you had to modify anything for Baja & Lodi 2.0
-- CBR VC Configuration Group (cbrDS1E1VcConfig)
-- CBR ATM Statistics Group (cbrDS1E1ATMStats)
-- For Baja & Lodi 2.0 onwards
-- CBR New VC Configuration Group (cbrDS1E1NewVcConfig)
cbrDS1E1NewVcConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF CbrDS1E1NewVcEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This object contains the CBR specific VC Configuration table.
There is one cbrDS1E1VcConfEntry associated for each CBR VC connection
provisioned within the shelf. This table uses vcPortSlot, vcPortPort,
vcPortTransmitVpi, vcPortTransmitVci, vcPortReceiveVpi, and
vcPortReceiveVci as an index which is defined in the vcBaseTable of
the C-PRODUCT BASE MIB. This index value uniquely identifies the CBR
VC connection to which this entry is applicable.
NOTE: The associated Circuit Emulation Service (CES) MIB defined by
the ATM forum restricts the VC index to a single 32-bit scalar value.
In support of this MIB, the CES MIB index retains the same indexing
information as the enterprise MIB (with the exception of using
vcPortReceiveVpi and vcPortReceiveVci) but has been bit-mapped using
the following construction:
vcPortPort bit 0..3
vcPortSlot bit 4..8
vcPortTransmitVci bit 9..23
vcPortTransmitVpi bit 24..31"
::= { cbrDS1E1NewVcConfig 1 }
cbrDS1E1NewVcConfEntry OBJECT-TYPE
SYNTAX CbrDS1E1NewVcEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the CBR specific VC Configuration table."
INDEX { vcpSideId }
::= { cbrDS1E1NewVcConfTable 1 }
CbrDS1E1NewVcEntry ::=
SEQUENCE {
cbrDS1E1NewVcConfCDVT
INTEGER,
cbrDS1E1NewVcConfIntegPeriod
INTEGER,
cbrDS1E1NewVcConfPayloadSize
INTEGER,
cbrDS1E1NewVcConfPayloadType
INTEGER,
cbrDS1E1NewVcConfOnHookDetection
INTEGER,
cbrDS1E1NewVcConfSignalingType
INTEGER,
cbrDS1E1NewVcConfDS0Channels
INTEGER
}
cbrDS1E1NewVcConfCDVT OBJECT-TYPE
SYNTAX INTEGER (1..31) -- UNITS msecs
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates the Cell Delay Variation Tolerance (CDVT)
in msecs configured for the specified T1/E1 ATM VC connection. The
CDVT value specifies the amount of cell delay uncertainty which may
be experienced by any particular cell. The maximum CDVT value for a
T1 interface is 24. The maximum CDVT value for an E1 interface is
31. The default value is 1 msec (1)."
DEFVAL { 1 }
::= { cbrDS1E1NewVcConfEntry 1 }
cbrDS1E1NewVcConfIntegPeriod OBJECT-TYPE
SYNTAX INTEGER (2000..65535) -- UNITS msecs
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates the Cell Loss Integration Period in msecs
configured for the specified ATM VC connection. If cell(s) are lost
within this period, the ATM Cell Loss Status (ACLS) is set to loss.
ACLS is accessible via the Circuit Emulation Service (CES) MIB defined
by the ATM forum and/or the VT100 ATM statistics screen. The default
value is 2500 msecs (2500)."
DEFVAL { 2500 }
::= { cbrDS1E1NewVcConfEntry 2 }
cbrDS1E1NewVcConfPayloadSize OBJECT-TYPE
SYNTAX INTEGER (1..47) -- UNITS bytes
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the actual number of payload octets used per
ATM cell size configured for the specified T1/E1 ATM VC connection.
The default value is 47 bytes (47)."
DEFVAL { 47 }
::= { cbrDS1E1NewVcConfEntry 3 }
cbrDS1E1NewVcConfPayloadType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
voice(2),
data(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates which payload type has been configured for the
specified T1/E1 ATM VC connection. It is reflective upon the T1/E1
port mode configuration (ie. none -> unstructured, voice -> structured
voice, data -> structured data). The default is none (1)."
DEFVAL { none }
::= { cbrDS1E1NewVcConfEntry 4 }
cbrDS1E1NewVcConfOnHookDetection OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object dynamically reallocates bandwidth based upon the detection
of an on-hook condition as specified by the signaling type. This
object is applicable in structured voice mode ONLY. The default
value is disabled (1)."
DEFVAL { disabled }
::= {cbrDS1E1NewVcConfEntry 5}
cbrDS1E1NewVcConfSignalingType OBJECT-TYPE
SYNTAX INTEGER {
no-signaling(1),
em-plar(2),
fxo-loop-start(3),
fxs-loop-start(4),
fxo-ground-start(5),
fxs-ground-start(6),
e1-r2(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates the associated signaling application type. This
object defaults to no_signaling in unstructured/structured data modes
and cannot be modified in these modes. This object can only be set in
structured voice mode. All signaling application type values are
applicable in this mode except for no-signaling. An error will result
if an attempt is made to set no_signaling in structured voice mode.
In addition, an error will result if an attempt is made to set e1-r2
to a T1 interface. The default value is no-signaling(1)."
DEFVAL { no-signaling }
::= { cbrDS1E1NewVcConfEntry 6 }
cbrDS1E1NewVcConfDS0Channels OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates the associated DS0's which have been assigned
to the specified ATM VC connection. All available DS0 channels are
automatically allocated in unstructured mode. In structured mode, the
DS0 channels are bit-coded with each bit representing one DS0 channel.
The following are some examples:
Value Representation
0x00000002 DS0-1 has been allocated to this VC
0x000007f0 DS0-4 to DS0-10 have been allocated to this VC
0x00027004 DS0-2, DS0-12 to DS0-14, DS0-17 have been allocated
DS0 channels can only be assigned in structured mode. Channel
conflicts within a T1/E1 port interface will result in an error.
For CBR V35 Port the valid values are as follows:
Channel Selection Value Data Rate
----------------- ------------ -----------
1 2 64k
1-2 6 128k
1-3 14 192k
1-4 30 256k
1-6 126 384k
1-8 510 512k
1-12 8190 768k
1-16 131070 1024k
1-24 33554430 1536k
"
::= { cbrDS1E1NewVcConfEntry 7 }
cbrDS1E1NewATMStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF CbrDS1E1NewATMStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This object contains the CBR specific VC Statistics table.
There is one cbrDS1E1ATMStatsEntry associated for each CBR VC connection
provisioned within the shelf. This table uses vcPortSlot, vcPortPort,
vcPortTransmitVpi, and vcPortTransmitVci as an index which is defined
in the vcBaseTable of the C-PRODUCT BASE MIB. This index value uniquely
identifies the CBR VC connection to which this entry is applicable.
Additional VC statistics information is available in the associated
Circuit Emulation Service (CES) MIB defined by the ATM forum.
NOTE: The associated Circuit Emulation Service (CES) MIB defined by
the ATM forum restricts the VC index to a single 32-bit scalar value.
In support of this MIB, the CES MIB index retains the same indexing
information as the enterprise MIB but has been bit-mapped using the
following construction:
vcPortPort bit 0..3
vcPortSlot bit 4..8
vcPortTransmitVci bit 9..23
vcPortTransmitVpi bit 24..31"
::= { cbrDS1E1NewATMStats 1 }
cbrDS1E1NewATMStatsEntry OBJECT-TYPE
SYNTAX CbrDS1E1NewATMStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the CBR specific VC Statistics table."
INDEX { vcpSideId }
::= { cbrDS1E1NewATMStatsTable 1 }
CbrDS1E1NewATMStatsEntry ::=
SEQUENCE {
cbrDS1E1NewATMStatsRxCells
Counter,
cbrDS1E1NewATMStatsTxCells
Counter,
cbrDS1E1NewATMStatsOOSErrors
Counter,
cbrDS1E1NewATMStatsCRCErrors
Counter,
cbrDS1E1NewATMStatsOAMRxCells
Counter,
cbrDS1E1NewATMStatsOAMTxCells
Counter,
cbrDS1E1NewATMStatsClearStats
INTEGER,
cbrDS1E1NewATMStatsResetTimeDate
TimeAndDate
}
cbrDS1E1NewATMStatsRxCells OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the total number of ATM cells received
over the T1/E1 ATM VC connection since the last ATM VC clear
time and date."
::= { cbrDS1E1NewATMStatsEntry 1 }
cbrDS1E1NewATMStatsTxCells OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the total number of ATM cells transmitted
over the T1/E1 ATM VC connection since the last ATM VC clear
time and date."
::= { cbrDS1E1NewATMStatsEntry 2 }
cbrDS1E1NewATMStatsOOSErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the total number of out-of-sequence errors
detected over the specified T1/E1 ATM VC connection since the last
ATM VC clear time and date."
::= { cbrDS1E1NewATMStatsEntry 3 }
cbrDS1E1NewATMStatsCRCErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the total number of CRC errors detected over
the specified T1/E1 ATM VC connection since the last ATM VC clear
time and date."
::= { cbrDS1E1NewATMStatsEntry 4 }
cbrDS1E1NewATMStatsOAMRxCells OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the total number of OAM cells received over
the specified T1/E1 ATM VC connection since the last ATM VC clear
time and date."
::= { cbrDS1E1NewATMStatsEntry 5 }
cbrDS1E1NewATMStatsOAMTxCells OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the total number of OAM cells transmitted over
the specified T1/E1 ATM VC connection since the last ATM VC clear
time and date."
::= { cbrDS1E1NewATMStatsEntry 6 }
cbrDS1E1NewATMStatsClearStats OBJECT-TYPE
SYNTAX INTEGER {
clear (1),
not-applicable (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object will (1) clear the ATM statistics counters and (2)
initialize the reset time and date to the current time and date
for the specified ATM VC connection. NOTE: A value of '2' is
returned for any attempted reads of this object."
::= { cbrDS1E1NewATMStatsEntry 7 }
cbrDS1E1NewATMStatsResetTimeDate OBJECT-TYPE
SYNTAX TimeAndDate
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicates the last time and date the ATM statistics
were cleared for the specified ATM VC connection."
::= { cbrDS1E1NewATMStatsEntry 8 }
END