C-PRODUCT-CBR-MIB DEFINITIONS ::= BEGIN IMPORTS cbr FROM C-PRODUCT-GROUP-MIB portSlot, portNumber, vcpSideId, TimeAndDate FROM C-PRODUCT-BASE-MIB Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- Data Types -- CBR groups cbrDS1E1CardConfig OBJECT IDENTIFIER ::= {cbr 1} cbrDS1E1PortConfig OBJECT IDENTIFIER ::= {cbr 2} cbrDS1E1VcConfig OBJECT IDENTIFIER ::= {cbr 3} cbrDS1E1ATMStats OBJECT IDENTIFIER ::= {cbr 4} cbrV35PortConfig OBJECT IDENTIFIER ::= {cbr 5} cbrDS1E1NewVcConfig OBJECT IDENTIFIER ::= {cbr 6} cbrDS1E1NewATMStats OBJECT IDENTIFIER ::= {cbr 7} -- CBR Card Configuration Group (cbrDS1E1CardConfig) cbrDS1E1CardConfTable OBJECT-TYPE SYNTAX SEQUENCE OF CbrDS1E1CardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object contains the CBR specific card Configuration table. There is one cbrDS1E1CardConfEntry associated for each provisioned CBR interface within the shelf. This table uses portSlot as an index which is defined in the portBaseTable of the C-PRODUCT BASE MIB. This index value uniquely identifies the CBR interface to which this entry is applicable." ::= {cbrDS1E1CardConfig 1} cbrDS1E1CardConfEntry OBJECT-TYPE SYNTAX CbrDS1E1CardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the CBR specific card Configuration table." INDEX { portSlot } ::= {cbrDS1E1CardConfTable 1} CbrDS1E1CardEntry ::= SEQUENCE { cbrDS1E1CardRefPort INTEGER } cbrDS1E1CardRefPort OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates which port the receive clock may be selected as the system reference clock source. The value range starts at 1 and the maximum value is dependent upon the total number of physical ports on the specified CBR interface. Four and eight port CBR intefaces are supported. An error is returned if this object is set outside the range of the specified physical card interface. In addition, an error is returned if this slot has been selected as the system reference clock and an attempt is made to change to a port not in-service. The default value is port 1 (1)." DEFVAL { 1 } ::= {cbrDS1E1CardConfEntry 1} -- CBR Port Configuration Group (cbrDS1E1PortConfig) cbrDS1E1PortConfTable OBJECT-TYPE SYNTAX SEQUENCE OF CbrDS1E1PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object contains the CBR specific port Configuration table. There is one cbrDS1E1PortConfEntry associated for each provisioned CBR port interface within the shelf. This table uses portSlot and portNumber as an index which is defined in the portBaseTable of the C-PRODUCT BASE MIB. This index value uniquely identifies the CBR port interface to which this entry is applicable." ::= {cbrDS1E1PortConfig 1} cbrDS1E1PortConfEntry OBJECT-TYPE SYNTAX CbrDS1E1PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the CBR specific port Configuration table." INDEX { portSlot, portNumber } ::= { cbrDS1E1PortConfTable 1 } CbrDS1E1PortEntry ::= SEQUENCE { cbrDS1E1PortConfLBO INTEGER, cbrDS1E1PortConfLineCode INTEGER, cbrDS1E1PortConfPortMode INTEGER, cbrDS1E1PortConfFraming INTEGER, cbrDS1E1PortConfTiming INTEGER, cbrDS1E1PortConfSignaling INTEGER, cbrDS1E1PortConfCRC-4 INTEGER, cbrDS1E1PortConfDS0Channels INTEGER, cbrDS1E1PortConfLoopBackType INTEGER } cbrDS1E1PortConfLBO OBJECT-TYPE SYNTAX INTEGER { dsx-0-110ft(1), dsx-110-220ft(2), dsx-220-330ft(3), dsx-330-440ft(4), dsx-440-550ft(5), dsx-550-600ft(6), dsx-GT-600ft(7) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is applicable to a T1-DSX CBR interface ONLY and indicates the associated Line Build Out configuration for the designated port. An error is returned if an access is attempted on a physical interface other than a T1-DSX port interface. The default value is 330 to 440 feet (4)." DEFVAL { dsx-330-440ft } ::= {cbrDS1E1PortConfEntry 1} cbrDS1E1PortConfLineCode OBJECT-TYPE SYNTAX INTEGER { ami(1), t1-B8ZS(2), e1-HDB3(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the zero code suppression technique configured to the specified T1/E1 port interface. The bipolar with 8 zero substitution (B8ZS) technique is applicable to T1 interfaces ONLY. The High Density Binary Three (HDB3) is applicable to E1 interfaces ONLY." ::= {cbrDS1E1PortConfEntry 2} cbrDS1E1PortConfPortMode OBJECT-TYPE SYNTAX INTEGER { unstructured(1), struct-voice(2), struct-data(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the type of service configured to the specified T1/E1 port interface. Unstructured allows the application to utilize the entire available bandwidth at a bit rate of 1.544 Mb/s for T1 or 2.048 Mb/s for E1. T1/E1 Framing is optional in this service mode. Structured service provides Nx64 kbit/s capability where N ranges between 1 and the maximum number of available DS0 channels. Struct-Voice passes traffic with signaling informaion enabled. Struct-Data passes traffic with signaling information disabled. Changing the mode configuration will cause the following parameters to be changed. . framing timing signaling crc-4 . ------- ------ --------- ----- . T1 unstructured unframed N/A N/A N/A . struct data ESF loop* N/A N/A . struct voice ESF loop* N/A N/A . E1 unstructured unframed N/A disable disable . struct data single loop* disable disable . struct voice multi loop* enable enable * timing is converted to loop timing only if timing is previously . configured to be in SRTS or adaptive timing modes NOTE: Changing this object to a different mode will cause all previously associated VCC's to be deleted. The default value for this object is unstructured (1)." DEFVAL { unstructured } ::= { cbrDS1E1PortConfEntry 3 } cbrDS1E1PortConfFraming OBJECT-TYPE SYNTAX INTEGER { unframed(1), t1-D4(2), t1-ESF(3), e1-single-frame(4), e1-multi-frame(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the type of frame organization configured for the specified T1/E1 port interface. D4 and ESF frame organizations apply to T1 interfaces ONLY. Single-frame and multi-frame organizations pertain to E1 interfaces ONLY. An error is returned if a set is applied to an inappropriate cardtype (eg. T1-D4 is applied to an E1 cardtype). Unframed is not a valid configuration in a structured mode. The E1 interface will not allow framing to be changed in structured voice mode. Changing the framing configuration for an E1 interface will cause the following parameters to be changed in unstructured and structured data modes. . signaling crc-4 . --------- ----- . E1 unframed disable disable . single-frame disable* disable . multi-frame enable* enable * signaling is automatically changed in unstructured mode only The default value is unframed (1)." DEFVAL { unframed } ::= { cbrDS1E1PortConfEntry 4 } cbrDS1E1PortConfTiming OBJECT-TYPE SYNTAX INTEGER { system(1), loop(2), srts(3), adaptive(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the type of input clock service configured for the specified T1/E1 port interface. Synchronous Residual Time Stamp (SRTS) and Adaptive timing modes are ONLY available in unstructured mode. System configures the port interface to use the system reference clock within the shelf as a reference for transmitting. Loop uses the input port Rx clock as the timing source. An error is returned if an access is attempted to set this object in an inappropriate port mode (eg. SRTS is applied in structured voice mode). The default value is adaptive (4)." DEFVAL { adaptive } ::= { cbrDS1E1PortConfEntry 5 } cbrDS1E1PortConfSignaling OBJECT-TYPE SYNTAX INTEGER { no-signaling(1), e1-CAS(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is applicable to E1 interfaces ONLY and indicates if signaling information is enabled or disabled. Signaling information is always disabled in E1 single-frame or unframed mode. Signaling information is always enabled in structured voice multi-frame mode. An error is returned if a set is applied to an inappropriate cardtype (eg. E1-CAS is applied to a T1 cardtype). In addition, the crc-4 configuration object is automatically disabled if the E1 interface is in unstructured multi-frame mode and signaling is disabled. NOTE: This object can ONLY be changed in E1 unstructured multi-frame mode. The default value is no-signaling (1)." DEFVAL { no-signaling } ::= { cbrDS1E1PortConfEntry 6 } cbrDS1E1PortConfCRC-4 OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is applicable to E1 interfaces ONLY and indicates if CRC-4 information is enabled or disabled. CRC-4 information is always disabled in E1 single-frame or unframed mode. CRC-4 information is always enabled in multi-frame mode with signaling disabled. NOTE: This object can ONLY be modified in E1 CAS multi-frame mode. The default value is disabled (1)." DEFVAL { disabled } ::= { cbrDS1E1PortConfEntry 7 } cbrDS1E1PortConfDS0Channels OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the associated DS0's which have been assigned to the specified physical port interface. All available DS0 channels are automatically allocated in unstructured mode. In structured mode, the DS0 channels are bit-coded with each bit representing one DS0 channel. The following are some examples: Value Representation 0x00000002 DS0-1 has been allocated to this port 0x000007f0 DS0-4 to DS0-10 have been allocated to this port 0x00027004 DS0-2, DS0-12 to DS0-14, DS0-17 have been allocated In E1 structured voice mode, the bit fields correspond to telephone channels and are automatically mapped to it's associated DS0 channel. Valid telephone channels range from 1 to 30. " ::= { cbrDS1E1PortConfEntry 8 } cbrDS1E1PortConfLoopBackType OBJECT-TYPE SYNTAX INTEGER { no-loopback(1), network-line(2), local-card(3), network-card(4), no-response(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the type of loopback configured for the specified T1/E1 port interface. Network-line (2) redirects incoming remote traffic back into the network interface at the external edge of the card interface. Network-card (4) regenerates framing information prior to redirecting incoming remote traffic back into the network interface. Local-card (3) redirects local incoming traffic back into the local system. The default value is no-loopback (1)." DEFVAL { no-loopback } ::= { cbrDS1E1PortConfEntry 9 } -- This definition is good only for Lodi 1.4 & 1.5, Use new implementation -- If you had to modify anything for Baja & Lodi 2.0 -- CBR VC Configuration Group (cbrDS1E1VcConfig) -- CBR ATM Statistics Group (cbrDS1E1ATMStats) -- For Baja & Lodi 2.0 onwards -- CBR New VC Configuration Group (cbrDS1E1NewVcConfig) cbrDS1E1NewVcConfTable OBJECT-TYPE SYNTAX SEQUENCE OF CbrDS1E1NewVcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object contains the CBR specific VC Configuration table. There is one cbrDS1E1VcConfEntry associated for each CBR VC connection provisioned within the shelf. This table uses vcPortSlot, vcPortPort, vcPortTransmitVpi, vcPortTransmitVci, vcPortReceiveVpi, and vcPortReceiveVci as an index which is defined in the vcBaseTable of the C-PRODUCT BASE MIB. This index value uniquely identifies the CBR VC connection to which this entry is applicable. NOTE: The associated Circuit Emulation Service (CES) MIB defined by the ATM forum restricts the VC index to a single 32-bit scalar value. In support of this MIB, the CES MIB index retains the same indexing information as the enterprise MIB (with the exception of using vcPortReceiveVpi and vcPortReceiveVci) but has been bit-mapped using the following construction: vcPortPort bit 0..3 vcPortSlot bit 4..8 vcPortTransmitVci bit 9..23 vcPortTransmitVpi bit 24..31" ::= { cbrDS1E1NewVcConfig 1 } cbrDS1E1NewVcConfEntry OBJECT-TYPE SYNTAX CbrDS1E1NewVcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the CBR specific VC Configuration table." INDEX { vcpSideId } ::= { cbrDS1E1NewVcConfTable 1 } CbrDS1E1NewVcEntry ::= SEQUENCE { cbrDS1E1NewVcConfCDVT INTEGER, cbrDS1E1NewVcConfIntegPeriod INTEGER, cbrDS1E1NewVcConfPayloadSize INTEGER, cbrDS1E1NewVcConfPayloadType INTEGER, cbrDS1E1NewVcConfOnHookDetection INTEGER, cbrDS1E1NewVcConfSignalingType INTEGER, cbrDS1E1NewVcConfDS0Channels INTEGER } cbrDS1E1NewVcConfCDVT OBJECT-TYPE SYNTAX INTEGER (1..31) -- UNITS msecs ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the Cell Delay Variation Tolerance (CDVT) in msecs configured for the specified T1/E1 ATM VC connection. The CDVT value specifies the amount of cell delay uncertainty which may be experienced by any particular cell. The maximum CDVT value for a T1 interface is 24. The maximum CDVT value for an E1 interface is 31. The default value is 1 msec (1)." DEFVAL { 1 } ::= { cbrDS1E1NewVcConfEntry 1 } cbrDS1E1NewVcConfIntegPeriod OBJECT-TYPE SYNTAX INTEGER (2000..65535) -- UNITS msecs ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the Cell Loss Integration Period in msecs configured for the specified ATM VC connection. If cell(s) are lost within this period, the ATM Cell Loss Status (ACLS) is set to loss. ACLS is accessible via the Circuit Emulation Service (CES) MIB defined by the ATM forum and/or the VT100 ATM statistics screen. The default value is 2500 msecs (2500)." DEFVAL { 2500 } ::= { cbrDS1E1NewVcConfEntry 2 } cbrDS1E1NewVcConfPayloadSize OBJECT-TYPE SYNTAX INTEGER (1..47) -- UNITS bytes ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the actual number of payload octets used per ATM cell size configured for the specified T1/E1 ATM VC connection. The default value is 47 bytes (47)." DEFVAL { 47 } ::= { cbrDS1E1NewVcConfEntry 3 } cbrDS1E1NewVcConfPayloadType OBJECT-TYPE SYNTAX INTEGER { none(1), voice(2), data(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates which payload type has been configured for the specified T1/E1 ATM VC connection. It is reflective upon the T1/E1 port mode configuration (ie. none -> unstructured, voice -> structured voice, data -> structured data). The default is none (1)." DEFVAL { none } ::= { cbrDS1E1NewVcConfEntry 4 } cbrDS1E1NewVcConfOnHookDetection OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object dynamically reallocates bandwidth based upon the detection of an on-hook condition as specified by the signaling type. This object is applicable in structured voice mode ONLY. The default value is disabled (1)." DEFVAL { disabled } ::= {cbrDS1E1NewVcConfEntry 5} cbrDS1E1NewVcConfSignalingType OBJECT-TYPE SYNTAX INTEGER { no-signaling(1), em-plar(2), fxo-loop-start(3), fxs-loop-start(4), fxo-ground-start(5), fxs-ground-start(6), e1-r2(7) } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the associated signaling application type. This object defaults to no_signaling in unstructured/structured data modes and cannot be modified in these modes. This object can only be set in structured voice mode. All signaling application type values are applicable in this mode except for no-signaling. An error will result if an attempt is made to set no_signaling in structured voice mode. In addition, an error will result if an attempt is made to set e1-r2 to a T1 interface. The default value is no-signaling(1)." DEFVAL { no-signaling } ::= { cbrDS1E1NewVcConfEntry 6 } cbrDS1E1NewVcConfDS0Channels OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the associated DS0's which have been assigned to the specified ATM VC connection. All available DS0 channels are automatically allocated in unstructured mode. In structured mode, the DS0 channels are bit-coded with each bit representing one DS0 channel. The following are some examples: Value Representation 0x00000002 DS0-1 has been allocated to this VC 0x000007f0 DS0-4 to DS0-10 have been allocated to this VC 0x00027004 DS0-2, DS0-12 to DS0-14, DS0-17 have been allocated DS0 channels can only be assigned in structured mode. Channel conflicts within a T1/E1 port interface will result in an error. For CBR V35 Port the valid values are as follows: Channel Selection Value Data Rate ----------------- ------------ ----------- 1 2 64k 1-2 6 128k 1-3 14 192k 1-4 30 256k 1-6 126 384k 1-8 510 512k 1-12 8190 768k 1-16 131070 1024k 1-24 33554430 1536k " ::= { cbrDS1E1NewVcConfEntry 7 } cbrDS1E1NewATMStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF CbrDS1E1NewATMStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object contains the CBR specific VC Statistics table. There is one cbrDS1E1ATMStatsEntry associated for each CBR VC connection provisioned within the shelf. This table uses vcPortSlot, vcPortPort, vcPortTransmitVpi, and vcPortTransmitVci as an index which is defined in the vcBaseTable of the C-PRODUCT BASE MIB. This index value uniquely identifies the CBR VC connection to which this entry is applicable. Additional VC statistics information is available in the associated Circuit Emulation Service (CES) MIB defined by the ATM forum. NOTE: The associated Circuit Emulation Service (CES) MIB defined by the ATM forum restricts the VC index to a single 32-bit scalar value. In support of this MIB, the CES MIB index retains the same indexing information as the enterprise MIB but has been bit-mapped using the following construction: vcPortPort bit 0..3 vcPortSlot bit 4..8 vcPortTransmitVci bit 9..23 vcPortTransmitVpi bit 24..31" ::= { cbrDS1E1NewATMStats 1 } cbrDS1E1NewATMStatsEntry OBJECT-TYPE SYNTAX CbrDS1E1NewATMStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the CBR specific VC Statistics table." INDEX { vcpSideId } ::= { cbrDS1E1NewATMStatsTable 1 } CbrDS1E1NewATMStatsEntry ::= SEQUENCE { cbrDS1E1NewATMStatsRxCells Counter, cbrDS1E1NewATMStatsTxCells Counter, cbrDS1E1NewATMStatsOOSErrors Counter, cbrDS1E1NewATMStatsCRCErrors Counter, cbrDS1E1NewATMStatsOAMRxCells Counter, cbrDS1E1NewATMStatsOAMTxCells Counter, cbrDS1E1NewATMStatsClearStats INTEGER, cbrDS1E1NewATMStatsResetTimeDate TimeAndDate } cbrDS1E1NewATMStatsRxCells OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the total number of ATM cells received over the T1/E1 ATM VC connection since the last ATM VC clear time and date." ::= { cbrDS1E1NewATMStatsEntry 1 } cbrDS1E1NewATMStatsTxCells OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the total number of ATM cells transmitted over the T1/E1 ATM VC connection since the last ATM VC clear time and date." ::= { cbrDS1E1NewATMStatsEntry 2 } cbrDS1E1NewATMStatsOOSErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the total number of out-of-sequence errors detected over the specified T1/E1 ATM VC connection since the last ATM VC clear time and date." ::= { cbrDS1E1NewATMStatsEntry 3 } cbrDS1E1NewATMStatsCRCErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the total number of CRC errors detected over the specified T1/E1 ATM VC connection since the last ATM VC clear time and date." ::= { cbrDS1E1NewATMStatsEntry 4 } cbrDS1E1NewATMStatsOAMRxCells OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the total number of OAM cells received over the specified T1/E1 ATM VC connection since the last ATM VC clear time and date." ::= { cbrDS1E1NewATMStatsEntry 5 } cbrDS1E1NewATMStatsOAMTxCells OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the total number of OAM cells transmitted over the specified T1/E1 ATM VC connection since the last ATM VC clear time and date." ::= { cbrDS1E1NewATMStatsEntry 6 } cbrDS1E1NewATMStatsClearStats OBJECT-TYPE SYNTAX INTEGER { clear (1), not-applicable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object will (1) clear the ATM statistics counters and (2) initialize the reset time and date to the current time and date for the specified ATM VC connection. NOTE: A value of '2' is returned for any attempted reads of this object." ::= { cbrDS1E1NewATMStatsEntry 7 } cbrDS1E1NewATMStatsResetTimeDate OBJECT-TYPE SYNTAX TimeAndDate ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the last time and date the ATM statistics were cleared for the specified ATM VC connection." ::= { cbrDS1E1NewATMStatsEntry 8 } END