113670 lines
3.3 MiB
Raw Blame History

This file contains invisible Unicode characters

This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

--
-- file :rad0545.pkb
--
RAD-MIB
--RAD0545-MIB
--Last revision: 04/11/08 SMI-v2
--
--
DEFINITIONS ::= BEGIN
-- Title: rad0545 MIB
-- Copyright 2000 RAD Data Communications, Ltd.
-- All Rights Reserved.
-- It is RAD's intent to encourage the widespread use of
-- this Specification in connection with the management of
-- RAD products. RAD grants vendors, end-users,
-- and other interested parties a non-exclusive license to
-- use this Specification in connection with the management
-- of RAD products.
-- This Specification is supplied "as is," and RAD makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.
IMPORTS
fddimibPORTPCMState FROM FDDI-SMT73-MIB
rptrGroupOperStatus,
rptrPortOperStatus FROM SNMP-REPEATER-MIB
rpMauMediaAvailable FROM MAU-MIB
-- OBJECT-TYPE ,
Integer32 , Counter32,
TimeTicks,enterprises,
IpAddress, Gauge32, Unsigned32,
OBJECT-TYPE, MODULE-IDENTITY,
NOTIFICATION-TYPE,
OBJECT-IDENTITY, Counter64 FROM SNMPv2-SMI
TimeStamp, TAddress,
TEXTUAL-CONVENTION,
DisplayString, RowStatus,
DateAndTime, TruthValue,
RowPointer FROM SNMPv2-TC
-- MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
AtmTrafficDescrParamIndex FROM ATM-TC-MIB
-- AtmTrafficDescrParamIndex,
atmVplVpi, atmVclVpi, atmVclVci,
aal5VccVpi, aal5VccVci,
atmVpCrossConnectEntry,
atmVcCrossConnectEntry,
atmTrafficDescrParamEntry,
atmVclEntry, aal5VccEntry FROM ATM-MIB
frPVCEndptDLCIIndex FROM FRNETSERV-MIB
VlanIndex, PortList,
dot1qVlanStaticEntry FROM Q-BRIDGE-MIB
atmfCESCbrIndex,
atmfCESConfEntry FROM ATMF-CES
InterfaceIndex, ifAlias,
ifIndex, InterfaceIndexOrZero, ifDescr FROM IF-MIB
imaGroupIndex, imaLinkIfIndex,
imaGroupFailureStatus FROM IMA-MIB
dsx1LineStatus,
dsx1LineStatusLastChange,
dsx1CurrentIndex, dsx1LineIndex,
dsx1IntervalIndex, dsx1IntervalNumber,
dsx1LoopbackStatus,
dsx1TotalIndex FROM DS1-MIB
dsx3LineStatus, dsx3ConfigEntry,
dsx3LoopbackStatus FROM DS3-MIB
PerfCurrentCount,
PerfIntervalCount,
PerfTotalCount FROM PerfHist-TC-MIB
MmTAddressTag,MmEndpointID,
MmAliasAddress,MmH323EndpointType,
MmGatekeeperID,MmAliasTag FROM MULTI-MEDIA-MIB-TC
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
isdnSignalingEntry FROM ISDN-MIB
frAtmIwfConnectionEntry FROM FR-ATM-PVC-SERVICE-IWF-MIB
hdsl2ShdslEndpointCurrEntry,
hdsl2ShdslInvIndex,
hdsl2ShdslEndpointSide,
hdsl2ShdslSpanConfProfileEntry FROM HDSL2-SHDSL-LINE-MIB
IANAifType FROM IANAifType-MIB
ipoaLisIfMappingEntry FROM IPOA-MIB
Timeout, BridgeId,
dot1dBasePortEntry FROM BRIDGE-MIB
apsConfigEntry FROM APS-MIB
-- MplsTunnelIndex, MplsOwner,
-- MplsLabel FROM MPLS-TC-STD-MIB
IndexIntegerNextFree,
IndexInteger FROM DIFFSERV-MIB
InetAddressType, InetAddress,
InetPortNumber FROM INET-ADDRESS-MIB
dsx0BundleEntry FROM DS0BUNDLE-MIB
MplsLabel, MplsTunnelIndex,
MplsOwner, MplsLdpIdentifier,
MplsLsrIdentifier FROM MPLS-TC-STD-MIB
schedEntry FROM DISMAN-SCHEDULE-MIB
LldpPortIdSubtype FROM LLDP-MIB
dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier,
dot1agCfmMepDbRMepIdentifier FROM IEEE8021-CFM-MIB
dot3OamEntry, dot3OamOperStatus FROM DOT3-OAM-MIB
IfIndexType FROM RFC1381-MIB;
-- Some MIB compilers need those two lines:
-- enterprises OBJECT IDENTIFIER ::=
-- { iso org(3) dod(6) internet(1) private(4) 1 }
rad MODULE-IDENTITY
LAST-UPDATED "200811041700Z"
ORGANIZATION "RAD MIB"
CONTACT-INFO
" Smadar Tauber
Postal: RAD Data Communications LTD.
24 Raoul Wallenberg St. (Ziv-Towers)
Tel-Aviv, Israel
Tel: +972-3-765-9973
Fax: +972-3-644-0930
E-mail: smadar_t@rad.com"
DESCRIPTION
"RAD MIB."
REVISION "200811041700Z"
DESCRIPTION
"RAD MIB, version 545."
REVISION "200808050830Z"
DESCRIPTION
"RAD MIB, version 541."
REVISION "200805271200Z"
DESCRIPTION
"RAD MIB, version 540."
REVISION "200801291815Z"
DESCRIPTION
"RAD MIB, version 535."
REVISION "200710111000Z"
DESCRIPTION
"RAD MIB, version 532."
REVISION "200707081500Z"
DESCRIPTION
"RAD MIB, version 531."
REVISION "200706071100Z"
DESCRIPTION
"RAD MIB, version 530."
REVISION "200611191300Z"
DESCRIPTION
"RAD MIB, version 527."
REVISION "200609281130Z"
DESCRIPTION
"RAD MIB, version 526."
REVISION "200604261030Z"
DESCRIPTION
"RAD MIB, version 525."
REVISION "200604051200Z"
DESCRIPTION
"RAD MIB, version 523.
Three new product OIDs added."
REVISION "200602140830Z"
DESCRIPTION
"RAD MIB, version 522."
REVISION "200512271000Z"
DESCRIPTION
"RAD MIB, version 521."
REVISION "200512011400Z"
DESCRIPTION
"RAD MIB, version 520."
REVISION "200505291315Z"
DESCRIPTION
"RAD MIB, version 517."
REVISION "200505221400Z"
DESCRIPTION
"RAD MIB, version 516."
REVISION "200505080815Z"
DESCRIPTION
"RAD MIB, version 515."
REVISION "200412051030Z"
DESCRIPTION
"RAD MIB, version 511."
REVISION "200411210930Z"
DESCRIPTION
"RAD MIB, version 510."
REVISION "200408301115Z"
DESCRIPTION
"RAD MIB, version 507."
REVISION "200406291244Z"
DESCRIPTION
"RAD MIB, version 506."
REVISION "200405171500Z"
DESCRIPTION
"RAD MIB, version 505."
REVISION "200404290745Z"
DESCRIPTION
"RAD MIB, version 501."
REVISION "200401131025Z"
DESCRIPTION
"RAD MIB, version 500."
REVISION "200401081100Z"
DESCRIPTION
"RAD MIB, version 496."
REVISION "200310091556Z"
DESCRIPTION
"RAD MIB, version 495."
REVISION "200304211240Z"
DESCRIPTION
"RAD MIB, version 491."
REVISION "200302090830Z"
DESCRIPTION
"RAD MIB, version 490."
REVISION "200210011220Z"
DESCRIPTION
"RAD MIB, version 485."
REVISION "200202191210Z"
DESCRIPTION
"RAD MIB, version 480."
::= { enterprises 164 }
-- rad OBJECT IDENTIFIER ::= { enterprises 164 }
radTokenRing OBJECT IDENTIFIER ::= { rad 1 } -- RAD Token Ring tree
radFddi OBJECT IDENTIFIER ::= { rad 2 } -- rad FDDI Tree
radWan OBJECT IDENTIFIER ::= { rad 3 } -- RAD WAN
radBridges OBJECT IDENTIFIER ::= {rad 4 }
radConverters OBJECT IDENTIFIER ::= { rad 5 } -- RAD Converters products' tree
radGen OBJECT IDENTIFIER ::= { rad 6} -- General information
radStkHub OBJECT IDENTIFIER ::= { rad 7 } -- stackable products
radPS OBJECT IDENTIFIER ::= { rad 8 } -- Packet Switch
--radEthRptr OBJECT IDENTIFIER ::= { rad 9 } - Ethernet Repeaters products
radMpls OBJECT IDENTIFIER ::= { rad 10 } -- MPLS
radRouter OBJECT IDENTIFIER ::= { rad 11 } -- Routers
rtrBridge OBJECT IDENTIFIER ::= { radRouter 7 }
radAtm OBJECT IDENTIFIER ::= { rad 12 } -- ATM Products
radPw OBJECT IDENTIFIER ::= { rad 14 } -- Pseudo Wire
--radEMS OBJECT IDENTIFIER ::= { rad 15 } - RAD EMS
radExperimental OBJECT IDENTIFIER ::= { rad 20 } -- Drafts that have no MIB tree yet
-- igmpStdMIB MODULE-IDENTITY ::= { radExperimental 1 }
-- apsMIB OBJECT IDENTIFIER ::= { radExperimental 2 } ; APS-R-MIB (ver522)
-- atmApsMIB OBJECT IDENTIFIER ::= { radExperimental 3 }
-- frsldMIB OBJECT IDENTIFIER ::= { radExperimental 4 }
-- cpIwfMIB OBJECT IDENTIFIER ::= { radExperimental 5 } ; CPIWF-R-MIB (atmaal2,ver522)
-- hdsl2ShdslMIB OBJECT IDENTIFIER ::= { radExperimental 6 }
-- dot3OamMIBR OBJECT IDENTIFIER ::= { radExperimental 7 } ; DOT3-OAM-R-MIB (ethOamAh, ver530)
-- mefMIBR OBJECT IDENTIFIER ::= { radExperimental 8 } ; MEF-R-MIB
-- ianaPwe3MIBR OBJECT IDENTIFIER ::= { radExperimental 9 } ; IANA-PWE3-R-MIB (same file with next)
-- pwStdMIBR OBJECT IDENTIFIER ::= { radExperimental 10 }; PW-STD-R-MIB (same file with previous)
-- pwTcStdMIBR OBJECT IDENTIFIER ::= { radExperimental 11 }; PW-TC-STD-R-MIB
-- pwMplsStdMIBR OBJECT IDENTIFIER ::= { radExperimental 12 }; PW-MPLS-STD-R-MIB
-- pwCTDMMIBR OBJECT IDENTIFIER ::= { radExperimental 13 }; PW-TDM-R-MIB
-- syslogMIBR OBJECT IDENTIFIER ::= { radExperimental 14 }; SYSLOG-R-MIB
-- bfdMIBR OBJECT IDENTIFIER ::= { radExperimental 15 }; BFD-STD-R-MIB
-- pwAtmMIBR OBJECT IDENTIFIER ::= { radExperimental 16 }; PW-ATM-R-MIB
MacAddress ::= OCTET STRING (SIZE(6))
TimeSlots ::= OCTET STRING (SIZE(4))
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\radgen.txt
--
-- File: RadGen.txt
systems OBJECT IDENTIFIER ::= { radGen 1} -- list of RAD products
--agnt OBJECT IDENTIFIER ::= { radGen 2} agent general tree
--services OBJECT IDENTIFIER ::= { radGen 3} See services.txt
--radTransport OBJECT IDENTIFIER ::= { radGen 4} RAD transport tree
radSysTR OBJECT IDENTIFIER ::= { systems 1 } -- RAD Token Ring
radRADring OBJECT IDENTIFIER ::= { radSysTR 1 }
radTMA OBJECT IDENTIFIER ::= { radSysTR 2 }
radRingMonitor OBJECT IDENTIFIER ::= { radSysTR 3 }
radSysFddi OBJECT IDENTIFIER ::= { systems 2 } -- RAD Fddi
radFDX100 OBJECT IDENTIFIER ::= { radSysFddi 1 } -- RAD Fddi
radSysWan OBJECT IDENTIFIER ::= { systems 3 } -- RAD Wan products
radSysWanEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for RAD Wan products."
::= { radSysWan 0 }
radMP2100 OBJECT IDENTIFIER ::= { radSysWan 1 }
radMP2104 OBJECT IDENTIFIER ::= { radSysWan 2 }
radMP2100B OBJECT IDENTIFIER ::= { radSysWan 3 }
radMP2100F OBJECT IDENTIFIER ::= { radSysWan 4 }
radMP2100H OBJECT IDENTIFIER ::= { radSysWan 5 }
radMP2104H OBJECT IDENTIFIER ::= { radSysWan 6 }
radMP2200B OBJECT IDENTIFIER ::= { radSysWan 7 }
radMP2200F OBJECT IDENTIFIER ::= { radSysWan 8 }
radMX3000 OBJECT IDENTIFIER ::= { radSysWan 9 }
radMX3004 OBJECT IDENTIFIER ::= { radSysWan 10 }
radMX30 OBJECT IDENTIFIER ::= { radSysWan 11 }
radMX300 OBJECT IDENTIFIER ::= { radSysWan 12 }
radVOIP OBJECT IDENTIFIER ::= { radSysWan 13 }
radKM2100 OBJECT IDENTIFIER ::= { radSysWan 15 }
radKM2104 OBJECT IDENTIFIER ::= { radSysWan 16 }
radDXC30 OBJECT IDENTIFIER ::= { radSysWan 20 }
radDXC10A OBJECT IDENTIFIER ::= { radSysWan 21 }
radDXC8R OBJECT IDENTIFIER ::= { radSysWan 22 }
radDXC30E OBJECT IDENTIFIER ::= { radSysWan 23 }
radDXC3000 OBJECT IDENTIFIER ::= { radSysWan 24 }
radDXC8RNew OBJECT IDENTIFIER ::= { radSysWan 25 }
radFcdT1LC OBJECT IDENTIFIER ::= { radSysWan 26 }
radFcdE1LC OBJECT IDENTIFIER ::= { radSysWan 27 }
radFcdT1L OBJECT IDENTIFIER ::= { radSysWan 28 }
radFcdE1L OBJECT IDENTIFIER ::= { radSysWan 29 }
radFcdT1 OBJECT IDENTIFIER ::= { radSysWan 30 }
radFcdE1 OBJECT IDENTIFIER ::= { radSysWan 31 }
radFcdE1I OBJECT IDENTIFIER ::= { radSysWan 32 }
radFcdT1M OBJECT IDENTIFIER ::= { radSysWan 33 }
radFcdE1M OBJECT IDENTIFIER ::= { radSysWan 34 }
radFcdIP OBJECT IDENTIFIER ::= { radSysWan 35}
radFcdT1A OBJECT IDENTIFIER ::= { radSysWan 36 }
radFcdE1A OBJECT IDENTIFIER ::= { radSysWan 37 }
radFcdW OBJECT IDENTIFIER ::= { radSysWan 38 }
radFcdSTM OBJECT IDENTIFIER ::= { radSysWan 39 }
radHtuE1Sa OBJECT IDENTIFIER ::= { radSysWan 40 }
radHtuE1 OBJECT IDENTIFIER ::= { radSysWan 41 } --card
radHtu2Sa OBJECT IDENTIFIER ::= { radSysWan 42 }
radHtu2 OBJECT IDENTIFIER ::= { radSysWan 43 } --card
radAsmi450R768Sa OBJECT IDENTIFIER ::= { radSysWan 44 }
radAsmi450R768 OBJECT IDENTIFIER ::= { radSysWan 45 } --card
radAsmi450R1152Sa OBJECT IDENTIFIER ::= { radSysWan 46 }
radAsmi450R1152 OBJECT IDENTIFIER ::= { radSysWan 47 } --card
radLrs12F OBJECT IDENTIFIER ::= { radSysWan 48 }
radLrs12B OBJECT IDENTIFIER ::= { radSysWan 49 }
radLrs52 OBJECT IDENTIFIER ::= { radSysWan 50 }
radHcdE1Sa OBJECT IDENTIFIER ::= { radSysWan 51 }
radHcdE1 OBJECT IDENTIFIER ::= { radSysWan 52 } --card
radHtuT1Sa OBJECT IDENTIFIER ::= { radSysWan 53 }
radHtuT1 OBJECT IDENTIFIER ::= { radSysWan 54 } --card
radOptimux4E1 OBJECT IDENTIFIER ::= { radSysWan 55 }
radOptimux4T1 OBJECT IDENTIFIER ::= { radSysWan 56 }
radOptimuxXLE1 OBJECT IDENTIFIER ::= { radSysWan 57 }
radOptimuxXLT1 OBJECT IDENTIFIER ::= { radSysWan 58 }
radOptimuxXL16E1 OBJECT IDENTIFIER ::= { radSysWan 59 }
radImx64 OBJECT IDENTIFIER ::= { radSysWan 60 }
radImx6L OBJECT IDENTIFIER ::= { radSysWan 61 }
radImx2 OBJECT IDENTIFIER ::= { radSysWan 62 }
radImx4T1 OBJECT IDENTIFIER ::= { radSysWan 63 }
radImx4E1 OBJECT IDENTIFIER ::= { radSysWan 64 }
radImx2T1E1 OBJECT IDENTIFIER ::= { radSysWan 65 }
radImxi4 OBJECT IDENTIFIER ::= { radSysWan 66 }
radOptimux155 OBJECT IDENTIFIER ::= { radSysWan 67 } --SA
radOptimux4T1L OBJECT IDENTIFIER ::= { radSysWan 68 } --SA Low Cost
radOptimux4E1L OBJECT IDENTIFIER ::= { radSysWan 69 } --SA Low Cost
radHtuE1SaV2 OBJECT IDENTIFIER ::= { radSysWan 70 }
radHtuE1V2 OBJECT IDENTIFIER ::= { radSysWan 71 } --card
radFomiE3 OBJECT IDENTIFIER ::= { radSysWan 72 } --card
radFomiT3 OBJECT IDENTIFIER ::= { radSysWan 73 } --card
radOpt4E1C OBJECT IDENTIFIER ::= { radSysWan 74 } --card
radOpt4T1C OBJECT IDENTIFIER ::= { radSysWan 75 } --card
radPrbiE3 OBJECT IDENTIFIER ::= { radSysWan 76 } --SA
radPrbiT3 OBJECT IDENTIFIER ::= { radSysWan 77 } --SA
radHcd4Sa OBJECT IDENTIFIER ::= { radSysWan 78 } --SA
radOptimuxT3 OBJECT IDENTIFIER ::= { radSysWan 79 } --SA
radFRmon OBJECT IDENTIFIER ::= { radSysWan 80 }
radIpMux4 OBJECT IDENTIFIER ::= { radSysWan 81 }
radIpMux1 OBJECT IDENTIFIER ::= { radSysWan 82 }
radIpMux16 OBJECT IDENTIFIER ::= { radSysWan 83 }
radIpMux1E OBJECT IDENTIFIER ::= { radSysWan 84 }
radVmux2100 OBJECT IDENTIFIER ::= { radSysWan 85 }
radMP104 OBJECT IDENTIFIER ::= { radSysWan 86 }
radMP204 OBJECT IDENTIFIER ::= { radSysWan 87 }
radVmux110 OBJECT IDENTIFIER ::= { radSysWan 88 }
-- reserved for radVmux105 OBJECT IDENTIFIER ::= { radSysWan 89 }
radFcd155 OBJECT IDENTIFIER ::= { radSysWan 90 } --SA
radIpMux8 OBJECT IDENTIFIER ::= { radSysWan 91 }
radOptimux155DS3 OBJECT IDENTIFIER ::= { radSysWan 92 } --SA
radOptimuxT3L OBJECT IDENTIFIER ::= { radSysWan 93 } --SA Low Cost
radGmux2000 OBJECT IDENTIFIER ::= { radSysWan 94 }
radOp16E1L OBJECT IDENTIFIER ::= { radSysWan 95 } --19 inch box
radOp16E1LS OBJECT IDENTIFIER ::= { radSysWan 96 } --half 19 inch box (single)
radPRBm20 OBJECT IDENTIFIER ::= { radSysWan 97 } -- half 19 inch box
radPRBm22 OBJECT IDENTIFIER ::= { radSysWan 98 } -- 19 inch box
radAsmi52A OBJECT IDENTIFIER ::= { radSysWan 99 } -- SA
radOpXLE1 OBJECT IDENTIFIER ::= { radSysWan 100 } -- New-Look
radOpXLT1 OBJECT IDENTIFIER ::= { radSysWan 101 } -- New-Look
radOpXL16E1 OBJECT IDENTIFIER ::= { radSysWan 102 } -- New-Look
radOp4E1 OBJECT IDENTIFIER ::= { radSysWan 103 } -- New-Look
radOp4T1 OBJECT IDENTIFIER ::= { radSysWan 104 } -- New-Look
radDxc4 OBJECT IDENTIFIER ::= { radSysWan 105 }
radIpMux11 OBJECT IDENTIFIER ::= { radSysWan 106 }
radIpMux14 OBJECT IDENTIFIER ::= { radSysWan 107 }
radOp1550 OBJECT IDENTIFIER ::= { radSysWan 108 }
-- reserved for radVplsMtu OBJECT IDENTIFIER ::= { radSysWan 109 }
radFdsl101 OBJECT IDENTIFIER ::= { radSysWan 110 }
radFdsl201 OBJECT IDENTIFIER ::= { radSysWan 111 }
radVmux120 OBJECT IDENTIFIER ::= { radSysWan 112 }
radVmux2200 OBJECT IDENTIFIER ::= { radSysWan 113 }
radVmux400 OBJECT IDENTIFIER ::= { radSysWan 114 }
radIpMux116 OBJECT IDENTIFIER ::= { radSysWan 115 }
radOp4E1LNew OBJECT IDENTIFIER ::= { radSysWan 116 } -- New SA Low Cost
radOp4T1LNew OBJECT IDENTIFIER ::= { radSysWan 117 } -- New SA Low Cost
radFcd155E OBJECT IDENTIFIER ::= { radSysWan 118 } -- 19 inch box, non APS
radFcd155ES OBJECT IDENTIFIER ::= { radSysWan 119 } -- half 19 inch box, APS
radMP4100 OBJECT IDENTIFIER ::= { radSysWan 120 }
radAsmi52L OBJECT IDENTIFIER ::= { radSysWan 121 } -- SA Low Cost
radVmux210 OBJECT IDENTIFIER ::= { radSysWan 122 }
radOp34E1 OBJECT IDENTIFIER ::= { radSysWan 123 }
radVmux312 OBJECT IDENTIFIER ::= { radSysWan 124 }
radVmux404 OBJECT IDENTIFIER ::= { radSysWan 125 }
radVmux420 OBJECT IDENTIFIER ::= { radSysWan 126 }
radIpMux12 OBJECT IDENTIFIER ::= { radSysWan 127 }
radOptimux4E1V3dot5 OBJECT IDENTIFIER ::= { radSysWan 128 }
radOptimux4E1Mar06 OBJECT IDENTIFIER ::= { radSysWan 129 }
radFcd155EwAPS OBJECT IDENTIFIER ::= { radSysWan 130 } -- 19 inch box, APS
radOptimux4T1Mar06 OBJECT IDENTIFIER ::= { radSysWan 131 }
radFcd155EwAPS2pdh OBJECT IDENTIFIER ::= { radSysWan 132 } -- 19 inch box, APS,E3 & E1
radVmux320 OBJECT IDENTIFIER ::= { radSysWan 133 }
radMP2100VoIP OBJECT IDENTIFIER ::= { radSysWan 134 }
radMP2104VoIP OBJECT IDENTIFIER ::= { radSysWan 135 }
radIpMux24 OBJECT IDENTIFIER ::= { radSysWan 136 }
radOp4E1NG1 OBJECT IDENTIFIER ::= { radSysWan 137 } -- OP-108
radOp4T1NG1 OBJECT IDENTIFIER ::= { radSysWan 138 } -- OP-106
radOp25 OBJECT IDENTIFIER ::= { radSysWan 139 } -- T1 interface
radAsmi54 OBJECT IDENTIFIER ::= { radSysWan 140 } -- SA
radVmux314 OBJECT IDENTIFIER ::= { radSysWan 141 }
radFcd622 OBJECT IDENTIFIER ::= { radSysWan 142 }
radLrs22 OBJECT IDENTIFIER ::= { radSysWan 143 }
radUNT20E1 OBJECT IDENTIFIER ::= { radSysWan 144 }
radIpMux2L OBJECT IDENTIFIER ::= { radSysWan 145 }
radFcdE1E OBJECT IDENTIFIER ::= { radSysWan 146 }
radIpMux216 OBJECT IDENTIFIER ::= { radSysWan 147 }
radLrs102 OBJECT IDENTIFIER ::= { radSysWan 148 }
radGmux2004 OBJECT IDENTIFIER ::= { radSysWan 149 }
radLrs102unbal OBJECT IDENTIFIER ::= { radSysWan 150 } -- LRS102 Unbalanced
radLrs16 OBJECT IDENTIFIER ::= { radSysWan 151 }
radVmux405 OBJECT IDENTIFIER ::= { radSysWan 152 }
radVmux425 OBJECT IDENTIFIER ::= { radSysWan 153 }
radMiniCVS OBJECT IDENTIFIER ::= { radSysWan 154 }
radIpMux155 OBJECT IDENTIFIER ::= { radSysWan 155 }
radSysBRG OBJECT IDENTIFIER ::= { systems 4 } -- RAD Bridges products
radTRE1 OBJECT IDENTIFIER ::= { radSysBRG 1 } -- RAD Bridges products
radTRE1D OBJECT IDENTIFIER ::= { radSysBRG 2 } -- RAD Bridges products
radTRE8 OBJECT IDENTIFIER ::= { radSysBRG 3 } -- RAD Bridges products
radTRE8D OBJECT IDENTIFIER ::= { radSysBRG 4 } -- RAD Bridges products
radMBE1 OBJECT IDENTIFIER ::= { radSysBRG 5 } -- RAD Bridges products
radMBE1D OBJECT IDENTIFIER ::= { radSysBRG 6 } -- RAD Bridges products
radMBE8 OBJECT IDENTIFIER ::= { radSysBRG 7 } -- RAD Bridges products
radMBE8D OBJECT IDENTIFIER ::= { radSysBRG 8 } -- RAD Bridges products
radMLBT OBJECT IDENTIFIER ::= { radSysBRG 9 } -- RAD Bridges products
radFEB4DAS OBJECT IDENTIFIER ::= { radSysBRG 10 } -- RAD Bridges products
radTrimBrg10 OBJECT IDENTIFIER ::= { radSysBRG 11 } -- RAD Bridges products
radTrimBrg16 OBJECT IDENTIFIER ::= { radSysBRG 12 } -- RAD Bridges products
radRRTRE8 OBJECT IDENTIFIER ::= { radSysBRG 13 } -- RAD Bridges products
radRRTRE8D OBJECT IDENTIFIER ::= { radSysBRG 14 } -- RAD Bridges products
radRRMLBT OBJECT IDENTIFIER ::= { radSysBRG 15 } -- RAD Bridges products
radRRMLBTF OBJECT IDENTIFIER ::= { radSysBRG 16 } -- RAD Bridges products
radRRTRE1D OBJECT IDENTIFIER ::= { radSysBRG 17 } -- RAD Bridges products
radTRERAS OBJECT IDENTIFIER ::= { radSysBRG 18 } -- RAD Bridges products
radTRERASa OBJECT IDENTIFIER ::= { radSysBRG 19 } -- RAD Bridges products
radMBERAS OBJECT IDENTIFIER ::= { radSysBRG 20 } -- RAD Bridges products
radMBERASa OBJECT IDENTIFIER ::= { radSysBRG 21 } -- RAD Bridges products
radFEB4FDX OBJECT IDENTIFIER ::= { radSysBRG 22 } -- RAD Bridges products
radFEB4SAS OBJECT IDENTIFIER ::= { radSysBRG 23 } -- RAD Bridges products
radRRFTBDAS OBJECT IDENTIFIER ::= { radSysBRG 24 } -- RAD Bridges products
radRRFTBSAS OBJECT IDENTIFIER ::= { radSysBRG 25 } -- RAD Bridges products
radFTBDAS OBJECT IDENTIFIER ::= { radSysBRG 26 } -- RAD Bridges products
radFTBSAS OBJECT IDENTIFIER ::= { radSysBRG 27 } -- RAD Bridges products
radFastWay100 OBJECT IDENTIFIER ::= { radSysBRG 28 } -- RAD Bridges products
radSysCnvrtr OBJECT IDENTIFIER ::= { systems 5 } -- RAD Converters products
radSTC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 1 } -- RAD Converters products
radSTC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 3 } -- RAD Converters products
radSTC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 4 } -- RAD Converters products
radSTC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 6 } -- RAD Converters products
radFTC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 10 } -- RAD Converters products
radFTC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 12 } -- RAD Converters products
radFTC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 13 } -- RAD Converters products
radFTC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 15 } -- RAD Converters products
radSEC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 20 } -- RAD Converters products
radSEC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 22 } -- RAD Converters products
radSEC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 23 } -- RAD Converters products
radSEC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 25 } -- RAD Converters products
radFEC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 30 } -- RAD Converters products
radFEC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 32 } -- RAD Converters products
radFEC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 33 } -- RAD Converters products
radFEC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 35 } -- RAD Converters products
radRIC155 OBJECT IDENTIFIER ::= { radSysCnvrtr 36 } -- RAD Converters products
radRICE1 OBJECT IDENTIFIER ::= { radSysCnvrtr 37 } -- RAD Converters products
radETX102 OBJECT IDENTIFIER ::= { radSysCnvrtr 38 } -- RAD Converters products
radRIC155GE OBJECT IDENTIFIER ::= { radSysCnvrtr 39 } -- RAD Converters products
radRiciT3 OBJECT IDENTIFIER ::= { radSysCnvrtr 40 } -- RAD Converters products
radRiciE3 OBJECT IDENTIFIER ::= { radSysCnvrtr 41 } -- RAD Converters products
radRiciT1 OBJECT IDENTIFIER ::= { radSysCnvrtr 42 } -- RAD Converters products
radETX202 OBJECT IDENTIFIER ::= { radSysCnvrtr 43 } -- RAD Converters products
radETX105 OBJECT IDENTIFIER ::= { radSysCnvrtr 44 } -- RAD Converters products
radETX205 OBJECT IDENTIFIER ::= { radSysCnvrtr 45 } -- RAD Converters products
radRiciSE OBJECT IDENTIFIER ::= { radSysCnvrtr 46 } -- RAD Converters products
radRIC622GE OBJECT IDENTIFIER ::= { radSysCnvrtr 47 } -- RAD Converters products
radSPH OBJECT IDENTIFIER ::= { radSysCnvrtr 48 } -- RAD Converters products
radMiricE1T1 OBJECT IDENTIFIER ::= { radSysCnvrtr 49 } -- RAD Converters products
radMiricE3T3 OBJECT IDENTIFIER ::= { radSysCnvrtr 50 } -- RAD Converters products
radSPH4 OBJECT IDENTIFIER ::= { radSysCnvrtr 51 } -- RAD Converters products
radEthAccess OBJECT IDENTIFIER ::= {systems 6}
radETX510 OBJECT IDENTIFIER ::= { radEthAccess 1 }
radEGate100 OBJECT IDENTIFIER ::= { radEthAccess 2 }
radEGate20 OBJECT IDENTIFIER ::= { radEthAccess 3 }
radRici8E1 OBJECT IDENTIFIER ::= { radEthAccess 4 }
radRici8T1 OBJECT IDENTIFIER ::= { radEthAccess 5 }
radRici4E1 OBJECT IDENTIFIER ::= { radEthAccess 6 }
radRici4T1 OBJECT IDENTIFIER ::= { radEthAccess 7 }
radIMXI4 OBJECT IDENTIFIER ::= { radEthAccess 8 }-- for Khazahstan only
radETX550 OBJECT IDENTIFIER ::= { radEthAccess 9 }
radRici16 OBJECT IDENTIFIER ::= { radEthAccess 10 }
radETX102A OBJECT IDENTIFIER ::= { radEthAccess 11 }
radETX202A OBJECT IDENTIFIER ::= { radEthAccess 12 }
radETX201A OBJECT IDENTIFIER ::= { radEthAccess 13 }
radETX201 OBJECT IDENTIFIER ::= { radEthAccess 14 }
radUNT20Ric OBJECT IDENTIFIER ::= { radEthAccess 15 }
radRici4E1L OBJECT IDENTIFIER ::= { radEthAccess 16 }
radRici8E1L OBJECT IDENTIFIER ::= { radEthAccess 17 }
radRici155GE OBJECT IDENTIFIER ::= { radEthAccess 18 }
radRici622GE OBJECT IDENTIFIER ::= { radEthAccess 19 }
radETX208 OBJECT IDENTIFIER ::= { radEthAccess 20 }
radETX202AW OBJECT IDENTIFIER ::= { radEthAccess 21 }--for wide box of ETX202A
radETX102H OBJECT IDENTIFIER ::= { radEthAccess 22 } -- Hardened metal box
radETX202H OBJECT IDENTIFIER ::= { radEthAccess 23 } -- Hardened metal box
radSysStkHub OBJECT IDENTIFIER ::= { systems 7 } -- RAD Stackable products
radRBHE OBJECT IDENTIFIER ::= { radSysStkHub 1 } -- RAD Stackable products
radRBHT OBJECT IDENTIFIER ::= { radSysStkHub 2 } -- RAD Stackable products
radRBHEEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for RAD Stackable products."
::= { radRBHE 0 }
radRBHTEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for RAD Stackable products."
::= { radRBHT 0 }
radETS4fddiDAS OBJECT IDENTIFIER ::= { radSysStkHub 3 } -- RAD Stackable products
radETS4fddiSAS OBJECT IDENTIFIER ::= { radSysStkHub 4 } -- RAD Stackable products
radSAHEMX OBJECT IDENTIFIER ::= { radSysStkHub 5 } -- RAD Stackable products
radSAHTM OBJECT IDENTIFIER ::= { radSysStkHub 6 } -- RAD Stackable products
radETS4 OBJECT IDENTIFIER ::= { radSysStkHub 7 } -- RAD Stackable products
radSAHEMU OBJECT IDENTIFIER ::= { radSysStkHub 8 } -- RAD Stackable products
unknown OBJECT IDENTIFIER ::= { radSysStkHub 9 } -- RAD Stackable products
radSAH16Eint OBJECT IDENTIFIER ::= { radSysStkHub 10 } -- RAD Stackable products
radSAH16Tint OBJECT IDENTIFIER ::= { radSysStkHub 11 } -- RAD Stackable products
radSAH16Eext OBJECT IDENTIFIER ::= { radSysStkHub 12 } -- RAD Stackable products
radSAH16Text OBJECT IDENTIFIER ::= { radSysStkHub 13 } -- RAD Stackable products
radSysPS OBJECT IDENTIFIER ::= { systems 8 } -- RAD Packet Switch (PS) products
radSysPSEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for RAD Packet Switch (PS) products."
::= { radSysPS 0 }
radSPS2 OBJECT IDENTIFIER ::= { radSysPS 1 } -- RAD Packet Switch (PS) products
radSPS3 OBJECT IDENTIFIER ::= { radSysPS 2 } -- RAD Packet Switch (PS) products
radSPS6 OBJECT IDENTIFIER ::= { radSysPS 3 } -- RAD Packet Switch (PS) products
radSPS9 OBJECT IDENTIFIER ::= { radSysPS 4 } -- RAD Packet Switch (PS) products
radSPS12 OBJECT IDENTIFIER ::= { radSysPS 5 } -- RAD Packet Switch (PS) products
radAPD2 OBJECT IDENTIFIER ::= { radSysPS 6 } -- RAD Packet Switch (PS) products
radAPD8 OBJECT IDENTIFIER ::= { radSysPS 7 } -- RAD Packet Switch (PS) products
radAPS8 OBJECT IDENTIFIER ::= { radSysPS 8 } -- RAD Packet Switch (PS) products
radAPS16 OBJECT IDENTIFIER ::= { radSysPS 9 } -- RAD Packet Switch (PS) products
radAPS24 OBJECT IDENTIFIER ::= { radSysPS 10 } -- RAD Packet Switch (PS) products
radSPS3S OBJECT IDENTIFIER ::= { radSysPS 11} -- RAD Packet Switch (PS) products
radFPS8 OBJECT IDENTIFIER ::= { radSysPS 12} -- RAD Packet Switch (PS) products
radFPS12 OBJECT IDENTIFIER ::= { radSysPS 13} -- RAD Packet Switch (PS) products
radSPS3ScSL OBJECT IDENTIFIER ::= { radSysPS 14} -- RAD Packet Switch (PS) products
radSPS3Sc2S OBJECT IDENTIFIER ::= { radSysPS 15} -- RAD Packet Switch (PS) products
radFPS8c OBJECT IDENTIFIER ::= { radSysPS 16} -- RAD Packet Switch (PS) products
radFPS4 OBJECT IDENTIFIER ::= { radSysPS 17} -- RAD Packet Switch (PS) products
radSPS4 OBJECT IDENTIFIER ::= { radSysPS 18} -- RAD Packet Switch (PS) products
radSysEth OBJECT IDENTIFIER ::= { systems 9 } -- RAD Ethernet products
radEP8T OBJECT IDENTIFIER ::= {radSysEth 1} -- RAD Ethernet products
radEP4TAUI OBJECT IDENTIFIER ::= {radSysEth 2} -- RAD Ethernet products
radEP4T2FL OBJECT IDENTIFIER ::= {radSysEth 3} -- RAD Ethernet products
radEP4TFL OBJECT IDENTIFIER ::= {radSysEth 4} -- RAD Ethernet products
radEP4FL OBJECT IDENTIFIER ::= {radSysEth 5} -- RAD Ethernet products
radEPR8T OBJECT IDENTIFIER ::= {radSysEth 7} -- RAD Ethernet products
radEPR4TAUI OBJECT IDENTIFIER ::= {radSysEth 8} -- RAD Ethernet products
radEPR4T2FL OBJECT IDENTIFIER ::= {radSysEth 9} -- RAD Ethernet products
radEPR4TFL OBJECT IDENTIFIER ::= {radSysEth 10} -- RAD Ethernet products
radEPR4FL OBJECT IDENTIFIER ::= {radSysEth 11} -- RAD Ethernet products
radSysRtr OBJECT IDENTIFIER ::= { systems 11 } -- RAD Router products
radSysRtrEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for RAD Router products."
::= { radSysRtr 0 }
radRTED OBJECT IDENTIFIER ::= {radSysRtr 1} -- RAD Router products
radRTEM OBJECT IDENTIFIER ::= {radSysRtr 2} -- RAD Router products
radRTEC OBJECT IDENTIFIER ::= {radSysRtr 3} -- RAD Router products
radWebRanger OBJECT IDENTIFIER ::= {radSysRtr 4} -- RAD Router products
radTinyRouter OBJECT IDENTIFIER ::= {radSysRtr 5} -- RAD Router products
radLA240 OBJECT IDENTIFIER ::= {radSysRtr 6} -- RAD Router products
radSuperLan OBJECT IDENTIFIER ::= {radSysRtr 7} -- RAD Router products (LA-240)
radLA240I OBJECT IDENTIFIER ::= {radSysRtr 8} -- RAD Router products
radFcdIsdn OBJECT IDENTIFIER ::= {radSysRtr 9} -- RAD Router products
radEFcdIp OBJECT IDENTIFIER ::= {radSysRtr 10} -- RAD Router products (FCD-IP/D)
radFcdIpD OBJECT IDENTIFIER ::= {radSysRtr 11} -- RAD Router products
radFcdIpM OBJECT IDENTIFIER ::= {radSysRtr 12} -- RAD Router products (LA-240)
radFcdIpL OBJECT IDENTIFIER ::= {radSysRtr 13} -- RAD Router products
radSysAtm OBJECT IDENTIFIER ::= { systems 12 } -- RAD ATM products
radSysAtmEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for RAD ATM products."
::= { radSysAtm 0 }
radStarSwitch OBJECT IDENTIFIER ::= {radSysAtm 1} --RAD StartSwitch products
radStarSwitchATM25 OBJECT IDENTIFIER ::= {radStarSwitch 1} --RAD StartSwitch products
radStarSwitchATM25L OBJECT IDENTIFIER ::= {radStarSwitch 2} --RAD StartSwitch products
radStarSwitchATM155 OBJECT IDENTIFIER ::= {radStarSwitch 3} --RAD StartSwitch products
radAtmCsuDsu OBJECT IDENTIFIER ::= {radSysAtm 2} --RAD CSU/DSU products
radAmcdE1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 1} -- RAD CSU/DSU products
radAmcdT1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 2} -- RAD CSU/DSU products
radAce20E OBJECT IDENTIFIER ::= {radAtmCsuDsu 3} -- RAD CSU/DSU products
radAce20T OBJECT IDENTIFIER ::= {radAtmCsuDsu 4} -- RAD CSU/DSU products
radAce2005 OBJECT IDENTIFIER ::= { radAtmCsuDsu 5} -- RAD ACE2005
radAce2002 OBJECT IDENTIFIER ::= { radAtmCsuDsu 6} -- RAD ACE2002
radAce2002E OBJECT IDENTIFIER ::= { radAtmCsuDsu 7} -- RAD ACE2002E
radAce2E OBJECT IDENTIFIER ::= {radAtmCsuDsu 8} -- RAD CSU/DSU products
radAce2T OBJECT IDENTIFIER ::= {radAtmCsuDsu 9} -- RAD CSU/DSU products
radMlAtmE1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 10} -- RAD ATM Piggy
radMlAtmT1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 11} -- RAD ATM Piggy
radAmc102 OBJECT IDENTIFIER ::= {radAtmCsuDsu 12} -- RAD AMC102
radAmc102c OBJECT IDENTIFIER ::= {radAtmCsuDsu 13} -- RAD AMC102 CARD
radAce202 OBJECT IDENTIFIER ::= { radAtmCsuDsu 14} -- RAD ACE202
radAce OBJECT IDENTIFIER ::= {radSysAtm 3} --RAD ACE products
radAce101 OBJECT IDENTIFIER ::= {radAce 1} -- RAD ACE101
radAce102 OBJECT IDENTIFIER ::= {radAce 2} -- RAD ACE102
radAce50 OBJECT IDENTIFIER ::= {radAce 3} -- RAD ACE50
radAce52 OBJECT IDENTIFIER ::= {radAce 4} -- RAD ACE52
radAce52L OBJECT IDENTIFIER ::= {radAce 5} -- RAD ACE52L
-- for radAce51 which was canceled
radAce201 OBJECT IDENTIFIER ::= {radAce 7} -- RAD ACE201
radAce3200 OBJECT IDENTIFIER ::= {radAce 8} -- RAD ACE3200
radAce3100 OBJECT IDENTIFIER ::= {radAce 9} -- RAD ACE3100
radAce3400 OBJECT IDENTIFIER ::= {radAce 10} -- RAD ACE3400
radAce3402 OBJECT IDENTIFIER ::= {radAce 11} -- RAD ACE3402
radAce3100PSN OBJECT IDENTIFIER ::= {radAce 12} -- RAD ACE3100/PSN
radAce3200PSN OBJECT IDENTIFIER ::= {radAce 13} -- RAD ACE3200/PSN
radAce3400PSN OBJECT IDENTIFIER ::= {radAce 14} -- RAD ACE3400/PSN
radAce3402PSN OBJECT IDENTIFIER ::= {radAce 15} -- RAD ACE3402/PSN
radAce3600 OBJECT IDENTIFIER ::= {radAce 16} -- RAD ACE3600
radAce3205 OBJECT IDENTIFIER ::= {radAce 17} -- RAD ACE3205
radAce3105 OBJECT IDENTIFIER ::= {radAce 18} -- RAD ACE3105
radAce3220 OBJECT IDENTIFIER ::= {radAce 19} -- RAD ACE3220
radSysLA OBJECT IDENTIFIER ::= {systems 13} --RAD IAD (Integrated Access Device) products
radLA140 OBJECT IDENTIFIER ::= {radSysLA 1} -- RAD LA-140
radLA110 OBJECT IDENTIFIER ::= {radSysLA 2} -- RAD LA-110
radLA104 OBJECT IDENTIFIER ::= {radSysLA 3} -- RAD LA-104 (LA-110 with IMA)
radLA130 OBJECT IDENTIFIER ::= {radSysLA 4}
radLA210 OBJECT IDENTIFIER ::= {radSysLA 5} -- RAD LA-210
radSysTerminal OBJECT IDENTIFIER ::= {systems 100} --RAD Terminal Meta-MIB;
-- no objects should be added to this branch in RAD MIB.
agnt OBJECT IDENTIFIER ::= { radGen 2}
-- agent general tree
-- Agent General
agnHwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ASCII string for description and display of the agent hardware version,
as it is known by the agent software.The user can update the version
upon request when he changes components in the agent's module "
::= { agnt 1 }
agnTrapMask OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this attribute determines the type of traps the
agent should mask and not send to the management console. The
value is differently determined for different products. There are
mainly two methods:
- an integer number, specifying the traps' severity.
- a sum of 2**n, where n is a bit assigned to a certain
masked trap group.
User should consult the product specification, to find out
the method employed."
::= { agnt 2 }
agnTrapValue OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The value of the trap decoded in internal RAD format. Full description is given
in the Trap definition file"
::= {agnt 3}
agnChangeCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of changes in system configuration that were reported to the
manager since last cold start"
::= {agnt 4 }
agnSpecific OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Object identifier of entity containing additional information
regarding this instance."
::= { agnt 5}
agnConfigMsg OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Full configuration message coded in internal RAD application format.
This entry describes agent's configuration.
For MP-2200 R3, this object describes agent's support of the V5.1
feature: 1 octet ; bit 0 (LSB).
'1' - V5.1 feature is supported
'0' - V5.1 feature is not supported."
::= { agnt 6 }
-- Manager table to record all IP addresses
mngTrapIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF MngEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table indicates the destination address of the traps.
Internally it will be limited to ten addresses. "
::= { agnt 7 }
mngEntry OBJECT-TYPE
SYNTAX MngEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mngID }
::= { mngTrapIpTable 1 }
MngEntry ::=
SEQUENCE {
mngID
Integer32,
mngIP
IpAddress,
mngIPMask
IpAddress,
mngTrapMask
Integer32,
mngAlarmTrapMask
OCTET STRING,
mngSnmpTrapUdpPort
Unsigned32
}
mngID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" This value indicates an index of a specific IP address"
::= { mngEntry 1 }
mngIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value indicates the destination address of the traps. IP 0.0.0.0 removes the entry. "
::= { mngEntry 2 }
mngIPMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This value indicates the mask of the destination addresses of the traps. "
::= { mngEntry 3 }
mngTrapMask OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this attribute determines the type of traps the
agent should mask and not send to this NMS. The
value is differently determined for different products. There are
mainly two methods:
- an integer number, specifying the traps' severity.
- a sum of 2**n, where n is a bit assigned to a certain
masked trap group.
User should consult the product specification, to find out
the method employed."
::= { mngEntry 4 }
mngAlarmTrapMask OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object determines the alarm traps that the
agent should mask (not send to this manager).
The value is an Octet String, where each bit
is assigned to a certain trap.
If the bit = 1, the trap will be masked.
If the bit = 0, the trap will not be masked.
For more details on the specific alarm traps masked,
see product specification."
::= { mngEntry 5 }
mngSnmpTrapUdpPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable enables to set the UDP port (socket) used for SNMP traps."
::= { mngEntry 6 }
agnIndication OBJECT-TYPE
SYNTAX INTEGER {
faulty (1), -- =major
warning (2),
normal (3), -- off
minor (4),
major (5),
event (6),
critical(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Attribute describing the state of the entity the agent is responsible for.
In case of a modular entity, the value of this attribute will be according
to the component which is in the worst state.
The order of severity (from top to bottom) is:
critical-> major (or faulty)-> minor-> event-> warning-> normal (off)."
::= { agnt 8 }
agnMonitorModeCmd OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON, will enforce the agent to change its mode of operation to
Monitor Mode"
::= {agnt 9}
agnLed OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the LEDs status of the agent module . Each led will be represented by 4
bits where the first 2 bits (left) will specify the status :
(00=NA, 01=OFF, 10=ON, 11=BLINK),
and the next two bits (right) will specify the color :
(00=GREEN, 01=RED, 10=YELLOW, 11=GRAY)"
::= {agnt 10}
trapTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table may include the last few traps generated by the agent, for future retrieval. The table
has a limited capacity. If traps are not retrieved in proper time, they will be
over-written by new traps.
For other devices, it can include generic variables that will be attached to traps
as 'accessible-for-notify'."
::= {agnt 11}
trapEntry OBJECT-TYPE
SYNTAX TrapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in trapTable."
INDEX { trapID }
::= { trapTable 1 }
TrapEntry ::=
SEQUENCE {
trapID
Integer32,
trapVal
DisplayString,
trapTimeSinceOccurrence
TimeTicks,
trapNumeric
Integer32
}
trapID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" This object indicates an index of a specific trap.
Can be used also for any trap, while trapVal is used
as 'accessible-for-notify' or trapNumeric is used."
::= { trapEntry 1 }
trapVal OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the actual ASCII description of the trap.
It can be used also as attached variable of traps, in order
to detail in explicit ASCII text, data of the trap.
In this case, it is used as 'accessible-for-notify'."
::= { trapEntry 2 }
trapTimeSinceOccurrence OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the amount of time passed since the occurrence of the event that
triggered this trap. "
::= { trapEntry 3 }
trapNumeric OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
" This object is a numeric general parameter, that can be attached to any trap.
Values can be positive or negative."
::= { trapEntry 4 }
fileTransfer OBJECT IDENTIFIER ::= { agnt 12 }
fileServerIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the server from which the file is loaded "
::= { fileTransfer 1 }
fileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the file to be loaded. For protection, read returns
NULL. "
::= { fileTransfer 2 }
fileTransCmd OBJECT-TYPE
SYNTAX INTEGER {
swDwnLoad (1),
configDwnLoad (2),
configUpLoad (3),
coProcDwnLoad (4),
stateUpLoad (5),
dwnLoadUserFile (6),
upLoadUserFile (7),
swDwnLoadAndReset (8),
swUpLoad (9),
swDwnLoad2BkupStorage(10),
bootDwnLoad (11),
bootUpLoad (12),
swUpLoadFromBkupStorage(13),
licenseDwnLoad (14),
configDwnLoadToDefaultFile(15),
noOp (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The command to be executed on fileName at fileServerIP."
::= { fileTransfer 3 }
-- tftp group
tftpRetryTimeOut OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" General Retransmission time-out value (seconds) "
-- DEFVAL { 15 }
::= { fileTransfer 4 }
tftpTotalTimeOut OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Total Retransmission time-out value (seconds) "
-- DEFVAL { 60 }
::= { fileTransfer 5 }
tftpStatus OBJECT-TYPE
SYNTAX INTEGER {
noOp(2),
connecting(3),
transferringData(4),
endedTimeOut(5),
endedOk(6),
error(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Status of tftp session. When a session ended with success,
the tftpStatus should be endedOk(6). Before restarting a
tftp session, the NMS should set the tftpStatus to noOp(2).
That's the reason of MAX-ACCESS read-write to this field."
DEFVAL { noOp}
::= { fileTransfer 6 }
tftpError OBJECT-TYPE
SYNTAX OCTET STRING ( SIZE(2) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The MSB represents the standard error code.
The LSB represents the private error code.
0x0000 is No Error
0x0100 is File Not Found
0x0200 is Access violation
0x0300 is Disk full or allocation exceeded
0x0400 is Illegal TFTP operation
0x0500 is Unknown transfer ID
0x0600 is File already exists
0x0700 is No such user
0x0001 is Server Overflow
0x0002 is No empty UDP port
0x0003 is No empty connection
0x0004 is Illegal File Mode
0x0007 is Illegal PDU size
0x0008 is TFTP Server does not exist
0x0009 is Incorrect File
0x000A is Wrong License format
0x000B is License ID already used"
DEFVAL { '0000'h }
::= { fileTransfer 7 }
fileTransferToSubSystems OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This object represents the sub-systems the fileTransCmd
refers to. It should be used when a system is divided
to sub-systems and each sub-system (or part of them) can
have a different SW/Configuration.
Each bit of this object will represent one of the sub-systems.
Bit='1' - APPLY to respective sub-system
Bit='0' - DO NOT APPLY to respective sub-system
For the meaning of each bit, see product's specification.
User will select the sub-systems envolved by filling-in the bits
that represent these sub-systems.
In this case, the file represented by 'fileName' will
include several parts, each representing one of the sub-systems.
The agent will refer only to the part/s indicated by this object.
0 Octet Strings = not applicable
DEFVAL = 0h for the products that support this object."
::= { fileTransfer 8 }
fileNameWithinProduct OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The file name used by the product within the product file system."
::= { fileTransfer 9 }
--Internal SW Download table
intSwdlTable OBJECT-TYPE
SYNTAX SEQUENCE OF IntSwdlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This parameters table is for
internal Software down load. It also includes data
about all files contained in the Object from which
down-load is performed."
::= { fileTransfer 10 }
intSwdlEntry OBJECT-TYPE
SYNTAX IntSwdlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {intSwdlObjIdx, intSwdlFileIdx }
::= { intSwdlTable 1}
IntSwdlEntry ::=
SEQUENCE {
intSwdlObjIdx Integer32,
intSwdlFileIdx Integer32,
intSwdlFileName DisplayString,
intSwdlFileSwVer DisplayString,
intSwdlSwDate DisplayString,
intSwdlSize DisplayString,
intSwdlCmd INTEGER,
intSwdlToSubSystem OCTET STRING,
intSwdlCardType INTEGER,
intSwdlFlashIdx Integer32
}
intSwdlObjIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the object from which down-load is performed."
::= {intSwdlEntry 1}
intSwdlFileIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the files included in intSwdlObjIdx.
One of these files can be selected to be internally
downloaded."
::= {intSwdlEntry 2}
intSwdlFileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the file."
::= {intSwdlEntry 3}
intSwdlFileSwVer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The software version of the file."
::= {intSwdlEntry 4}
intSwdlSwDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The software version date of the file."
::= {intSwdlEntry 5}
intSwdlSize OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The size of the file."
::= {intSwdlEntry 6}
intSwdlCmd OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The command to down-load a SW file to an object.
The Agent will change the value of this MIB object to off(2)
automatically, after accepting the command."
::= {intSwdlEntry 7}
intSwdlToSubSystem OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This object defines the subsystem for download.
Bit='1'- APPLY to respective sub system.
Bit='0'- DO NOT APPLY to respective sub system.
For more details see product specification.
For every octet bit0=LSB, bit7=MSB"
::= { intSwdlEntry 8 }
intSwdlCardType OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
gstm1 (220), -- GMUX-2000 STM1 card
goc3 (221), -- GMUX-2000 OC3 card
gstm1D (222), -- GMUX-2000 STM1 card with 2 ports
goc3D (223), -- GMUX-2000 OC3 card with 2 ports
serverE1 (270), -- GMUX-2000 Server E1 Card
serverT1 (271), -- GMUX-2000 Server T1 Card
serverE1Pw (272), -- Gmux2000 Server E1 PW Card
serverT1Pw (273), -- Gmux2000 Server T1 PW Card
gigabitEth (280), -- GMUX-2000 Gigabit ETH Card
gigabitEth2 (281), -- Gmux2000 new Gigabit ETH Card - 2 GbE ports with SFP connector
eth2 (282), -- Gmux2000 new ETH Card - 2 ETH ports with RJ45 connectors (10/100/1000)
gigabitEth8 (283), -- Gmux2000 new Gigabit ETH Card - 8 GbE ports with SFP connector
eth8 (284), -- Gmux2000 new ETH Card - 8 ETH ports with RJ45 connectors (10/100/1000)
channelizedT3Pw1 (290), -- Gmux2000 Channelized T3 PW Card
cesT128 (300), -- Gmux-2000 CES T1 28 ports (external T1 ports) card.
cesE128 (301), -- Gmux-2000 CES E1 28 ports (external E1 ports) card.
cesT1Pw28 (302), -- Gmux2000 CES T1 PW ports (external T1 ports) card.
cesE1Pw28 (303), -- Gmux2000 CES E1 PW ports (external E1 ports) card.
vmxE1VeDe (310), -- Gmux-2000 Vmux E1 card with 16 external voice + 2 external Data ports.
vmxE1VeDi (311), -- Gmux-2000 Vmux E1 card with 16 external voice + 2 internal Data ports.
vmxE1ViDe (312), -- Gmux-2000 Vmux E1 card with 16 internal voice + 2 external Data ports.
vmxE1ViDi (313), -- Gmux-2000 Vmux E1 card with 16 internal voice + 2 internal Data ports.
vmxT1VeDe (314), -- Gmux-2000 Vmux T1 card with 16 external voice + 2 external Data ports.
vmxT1VeDi (315), -- Gmux-2000 Vmux T1 card with 16 external voice + 2 internal Data ports.
vmxT1ViDe (316), -- Gmux-2000 Vmux T1 card with 16 internal voice + 2 external Data ports.
vmxT1ViDi (317), -- Gmux-2000 Vmux T1 card with 16 internal voice + 2 internal Data ports.
vc12E1UeNe (318), -- Gmux-2000 Vmux E1 card with 12 external User (voice) + 2 external Network (Data) ports.
vc12E1UeNi (319), -- Gmux-2000 Vmux E1 card with 12 external User (voice) + 2 internal Network (Data) ports.
vc12E1UiNe (320), -- Gmux-2000 Vmux E1 card with 12 internal User (voice) + 2 external Network (Data) ports.
vc12E1UiNi (321), -- Gmux-2000 Vmux E1 card with 12 internal User (voice) + 2 internal Network (Data) ports.
vc12T1UeNe (322), -- Gmux-2000 Vmux T1 card with 12 external User (voice) + 2 external Network (Data) ports.
vc12T1UeNi (323), -- Gmux-2000 Vmux T1 card with 12 external User (voice) + 2 internal Network (Data) ports.
vc12T1UiNe (324), -- Gmux-2000 Vmux T1 card with 12 internal User (voice) + 2 external Network (Data) ports.
vc12T1UiNi (325), -- Gmux-2000 Vmux T1 card with 12 internal User (voice) + 2 internal Network (Data) ports.
vca16E1UeNe (326), -- Gmux-2000 VCA E1 card with 16 external User (voice) + 2 external Network (Data) ports.
vca16E1UeNi (327), -- Gmux-2000 VCA E1 card with 16 external User (voice) + 2 internal Network (Data) ports.
vca16E1UiNe (328), -- Gmux-2000 VCA E1 card with 16 internal User (voice) + 2 external Network (Data) ports.
vca16E1UiNi (329), -- Gmux-2000 VCA E1 card with 16 internal User (voice) + 2 internal Network (Data) ports.
vca16T1UeNe (330), -- Gmux-2000 VCA T1 card with 16 external User (voice) + 2 external Network (Data) ports.
vca16T1UeNi (331), -- Gmux-2000 VCA T1 card with 16 external User (voice) + 2 internal Network (Data) ports.
vca16T1UiNe (332), -- Gmux-2000 VCA T1 card with 16 internal User (voice) + 2 external Network (Data) ports.
vca16T1UiNi (333), -- Gmux-2000 VCA T1 card with 16 internal User (voice) + 2 internal Network (Data) ports.
vca12E1UeNe (334), -- Gmux-2000 VCA E1 card with 12 external User (voice) + 2 external Network (Data) ports.
vca12E1UeNi (335), -- Gmux-2000 VCA E1 card with 12 external User (voice) + 2 internal Network (Data) ports.
vca12E1UiNe (336), -- Gmux-2000 VCA E1 card with 12 internal User (voice) + 2 external Network (Data) ports.
vca12E1UiNi (337), -- Gmux-2000 VCA E1 card with 12 internal User (voice) + 2 internal Network (Data) ports.
vca12T1UeNe (338), -- Gmux-2000 VCA T1 card with 12 external User (voice) + 2 external Network (Data) ports.
vca12T1UeNi (339), -- Gmux-2000 VCA T1 card with 12 external User (voice) + 2 internal Network (Data) ports.
vca12T1UiNe (340), -- Gmux-2000 VCA T1 card with 12 internal User (voice) + 2 external Network (Data) ports.
vca12T1UiNi (341), -- Gmux-2000 VCA T1 card with 12 internal User (voice) + 2 internal Network (Data) ports.
vmg16E1Ue (342), -- Gmux-2000 VMG (Media Gateway) E1 card with 16 external User ports
vmg16E1Ui (343), -- Gmux-2000 VMG (Media Gateway) E1 card with 16 internal User ports
vmg16T1Ue (344), -- Gmux-2000 VMG (Media Gateway) T1 card with 16 external User ports
vmg16T1Ui (345), -- Gmux-2000 VMG (Media Gateway) T1 card with 16 internal User ports
vmg12E1Ue (346), -- Gmux-2000 VMG (Media Gateway) E1 card with 12 external User ports
vmg12E1Ui (347), -- Gmux-2000 VMG (Media Gateway) E1 card with 12 internal User ports
vmg12T1Ue (348), -- Gmux-2000 VMG (Media Gateway) T1 card with 12 external User ports
vmg12T1Ui (349) -- Gmux-2000 VMG (Media Gateway) T1 card with 12 internal User ports
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines the Card type that this file is relevant for."
::= {intSwdlEntry 9}
intSwdlFlashIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the flash memory this file is stored in (1 or 2)
(Example: 1= The file is stored in flash No.1).
ASMi52 file will always be stored in Flash No.2 (intSwdlFlashIdx=2)."
::= {intSwdlEntry 10}
--SW Download Status table
swdlStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwdlStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This parameters table is for software download status.
It also includes data about the files down-loaded or
attempted to be down-loaded."
::= { fileTransfer 11 }
swdlStatusEntry OBJECT-TYPE
SYNTAX SwdlStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {swdlStatusTypeIdx, swdlStatusIdx }
::= { swdlStatusTable 1}
SwdlStatusEntry ::=
SEQUENCE {
swdlStatusTypeIdx Integer32,
swdlStatusIdx Integer32,
swdlStatusFileName DisplayString,
swdlStatusSlot DisplayString,
swdlStatusSubSystem DisplayString,
swdlStatusStatus Integer32,
swdlStatusTime DisplayString
}
swdlStatusTypeIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the down-load type (e.g. external (1) or internal (2))."
::= {swdlStatusEntry 1}
swdlStatusIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the status rows."
::= {swdlStatusEntry 2}
swdlStatusFileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the file."
::= {swdlStatusEntry 3}
swdlStatusSlot OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot of the updated (or attempted to be updated) object."
::= {swdlStatusEntry 4}
swdlStatusSubSystem OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The subsystem that updated (or attempted to be updated)."
::= {swdlStatusEntry 5}
swdlStatusStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the down load process.
Value: Fail (2), OK (3), InProcess (4)."
::= {swdlStatusEntry 6}
swdlStatusTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This MIB parameter indicates the time SW download was finished.
The format shuld be YYYY-MM-DD, hh:mm:ss"
::= {swdlStatusEntry 7}
clearDwldStatusLog OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object clears the status log.
Value: off(2), external(3), internal(4)
The Agent will change the value of this MIB object to off(2)
automatically, after accepting the command ."
::= { fileTransfer 12 }
autoFileTransfer OBJECT IDENTIFIER ::= { fileTransfer 13}
-- Agent initiated auto file transfer.
autoFileTransferTable OBJECT-TYPE
SYNTAX SEQUENCE OF AutoFileTransferEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Scheduling configuration table for
Agent initiated file transfer."
::= { autoFileTransfer 1 }
autoFileTransferEntry OBJECT-TYPE
SYNTAX AutoFileTransferEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table."
INDEX { autoFileTransferType}
::= { autoFileTransferTable 1}
AutoFileTransferEntry ::=
SEQUENCE {
autoFileTransferType
INTEGER,
autoFileTransferServerIp
IpAddress,
autoFileTransferFileName
SnmpAdminString,
autoFileTransferScheduling
INTEGER,
autoFileTransferTimeRecurrence
Integer32,
autoFileTransferOccurrenceRecurrence
Integer32
}
autoFileTransferType OBJECT-TYPE
SYNTAX INTEGER
{
alarmsBuffer (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines the type of file to be transferred
by agent. "
::= { autoFileTransferEntry 1 }
autoFileTransferServerIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the IP Address of the
server to which the file is uploaded."
::= { autoFileTransferEntry 2 }
autoFileTransferFileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the name of
the file to be uploaded."
::= { autoFileTransferEntry 3 }
autoFileTransferScheduling OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
now (2),
recurrence (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines schedule for TFTP Automatic session(s)
initiated by Agent, according to the value selected:
now - initiate immediate single session.
recurrence- initiate single session 'every M time units'.
or 'every N occurrences' or upon both, (earliest event).
Time reccurence period (M) is defined by
fileTransferTimeRecurrence.
Occurrence reccurence (N) is defined by
fileTransferOccurrenceRecurrence.
Zero value means that the object is not relevant (not
taken into account for the recurrence). It is invalid
that both will have zero values in our case (recurrence).
When both are non zero, file is transferred
upon earliest event"
::= { autoFileTransferEntry 4 }
autoFileTransferTimeRecurrence OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines time reccurence interval,
e.g. M can be 'every M days', 'every M hours' etc.
Zero is used to indicate
there's no time reccurence (0= notApplicable).
This object is taken into account only
if autoFileTransferScheduling = recurrence
For LA-110 time units are days."
::= { autoFileTransferEntry 5 }
autoFileTransferOccurrenceRecurrence OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines Occurrence reccurence interval,
e.g N can be in 'every N alarms', 'every N log entries' etc.
zero is used to indicate
There's no Event Reccurence. (0= notApplicable)
This object is taken into account only
if autoFileTransferScheduling = recurrence
Occurence Type (Alarms, etc.) is according
to autoFileTransferType."
::= { autoFileTransferEntry 6 }
fileTransferServerPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Server Port number used for File Transfer.
Applicable for SFTP.
Valid values: 0..65535."
-- DEFVAL { 22 }
::= { fileTransfer 14 }
fileTransferProtocol OBJECT-TYPE
SYNTAX INTEGER
{
tftp (1), --default
sftp (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"File Transfer protocol used."
::= { fileTransfer 15 }
systemReset OBJECT-TYPE
SYNTAX INTEGER {
off (2),
on (3), --HW
resetConfig (4),
resetMapping (5),
resetStandby (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset action to be performed on the system.
- resetMapping - reset SDH/SONET mapping to
default for all SDH/SONET links.
- resetStandby(6) - can be used only by devices with redundancy on MAIN/CL."
::= { agnt 13 }
systemTiming OBJECT IDENTIFIER ::= { agnt 14 }
systemDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System date."
::= { systemTiming 1 }
systemTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System time."
::= { systemTiming 2 }
systemTimeElapsed OBJECT-TYPE
SYNTAX Integer32 (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since the
beginning of the current error-measurement
period. Same for all ports of the device."
::= { systemTiming 3 }
systemNtp OBJECT IDENTIFIER ::= { systemTiming 4 } -- Network Time Protocol
systemNtpMode OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
broadcastClient (3),
unicastClient (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable represents the NTP Mode."
::= { systemNtp 1 }
systemNtpGmt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable represents the NTP GMT (Greenwich Mean Time),
Possible values range is -12..12.
For new devices/versions this variable will be in minutes."
::= { systemNtp 2 }
systemNtpServerAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable represents the NTP Server Address Type."
::= { systemNtp 3 }
systemNtpServerAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable represents the NTP Server Address."
::= { systemNtp 4 }
systemNtpUpdateInterval OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable represents the NTP Update Interval,
measured in seconds. It means, minimum time between two
consecutive NTP requests."
::= { systemNtp 5 }
systemNtpCmd OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
sendUpdateRequest (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable represents NTP possible commands.
After the Agent accepts a command, it will automatically change
the value to off(2)."
::= { systemNtp 6 }
systemNtpTimeSinceLastPoll OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time in seconds, that passed from last polling of the configured
SNTP servers. 0=Not Applicable (when this time is not known)."
::= { systemNtp 7 }
systemNtpModeBITS OBJECT-TYPE
SYNTAX BITS{
broadcastClient(0)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If Bit 0 (broadcastClient) is '1', Broadcast Mode is enabled,
meaning that the device listens to the NTP broadcast messages
and learns timestamps from them.
If disabled (Bit 0 = '0'), the device ignores NTP broadcast
messages.
Unicast mode is always enabled, therefore there is no special
Bit for it."
::= { systemNtp 8 }
systemNtpCurrentSourceType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type IP address of the NTP server currently providing system TOD."
::= { systemNtp 9 }
systemNtpCurrentSource OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP Address (ipv4) of the Server (or Local HW) providing the
current Date and Time of the device.
127.0.0.1 = local HW clock is used.
0.0.0.0 = no clock is available."
::= { systemNtp 10 }
sntpServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF SntpServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains parameters for each NTP Server.
Entries in the table can be dynamically created.
The entries created by user via sntpServerRowStatus, can also be
changed or removed.
The table may include also Broadcast Servers, when Broadcast
Client Mode is enabled. These are Servers from which the device
received timestamp by Broadcast. Their entries are automatically
created by the device. Entries of these Servers cannot
be changed or removed."
::= { systemNtp 11 }
sntpServerEntry OBJECT-TYPE
SYNTAX SntpServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the NTP Server table."
INDEX { sntpServerID }
::= { sntpServerTable 1 }
SntpServerEntry ::= SEQUENCE {
sntpServerID Unsigned32,
sntpServerRowStatus RowStatus,
sntpServerAddressType InetAddressType,
sntpServerAddress InetAddress,
sntpServerPort InetPortNumber,
sntpServerPreference Unsigned32,
sntpServerAdminStatus INTEGER,
sntpServerType INTEGER,
sntpServerLastReceivedTimestamp DateAndTime,
sntpServerLastReceivedStratum Unsigned32,
sntpServerTimeSinceLastReceivedMessage TimeTicks,
sntpServerSendRequestNow INTEGER
}
sntpServerID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The number (index) of the NTP Server."
::= { sntpServerEntry 1 }
sntpServerRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables creation and deletion of entries
in the sntpServerTable."
::= { sntpServerEntry 2 }
sntpServerAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Server Address type, indicating IPv4(1) or IPv6(2)."
::= { sntpServerEntry 3 }
sntpServerAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"IP Address of the NTP Server."
::= { sntpServerEntry 4 }
sntpServerPort OBJECT-TYPE
SYNTAX InetPortNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Source UDP port of the device for sending requests to
a configured NTP Server."
DEFVAL {123}
::= { sntpServerEntry 5 }
sntpServerPreference OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object marks the Preferred Server.
1 = Preferred (only one Server can have this value)
2 - Not Preferred."
::= { sntpServerEntry 6 }
sntpServerAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up (1),
down(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Administrative Status of the NTP Server."
::= { sntpServerEntry 7 }
sntpServerType OBJECT-TYPE
SYNTAX INTEGER {
unicast (1),
broadcast(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of the NTP Server."
::= { sntpServerEntry 8 }
sntpServerLastReceivedTimestamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last received Date and Time from the NTP Server, according to
Local Time.
0000 0000 = Not Applicable."
::= { sntpServerEntry 9 }
sntpServerLastReceivedStratum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last received Stratum from the NTP Server.
0xFFFFFFFF = Not Applicable."
::= { sntpServerEntry 10 }
sntpServerTimeSinceLastReceivedMessage OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time passed since last received message from the NTP Server."
::= { sntpServerEntry 11 }
sntpServerSendRequestNow OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Upon setting this parameter to 'on', an immediate request
should be sent to the specified NTP Server.
After sending the request, the value 'off' will be resumed.
No action when setting this parameter to 'off'"
::= { sntpServerEntry 12 }
schedXTable OBJECT-TYPE
SYNTAX SEQUENCE OF SchedXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Augment to the Schedule table
(schedTable in DISMAN-SCHEDULE-MIB; RFC-3231)."
::= { systemTiming 5 }
schedXEntry OBJECT-TYPE
SYNTAX SchedXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
AUGMENTS { schedEntry }
::= { schedXTable 1 }
SchedXEntry ::=
SEQUENCE {
schedYear Unsigned32,
schedWeekInMonth INTEGER,
schedParam Integer32
}
schedYear OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The year during which the scheduled action should take place."
::= { schedXEntry 1 }
schedWeekInMonth OBJECT-TYPE
SYNTAX INTEGER {
first (1),
second (2),
third (3),
fourth (4),
last (5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The week in month (schedMonth) during which the scheduled action
should take place."
::= { schedXEntry 2 }
schedParam OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A Parameter that might be used whenever the scheduled action takes place.
For summer-time schedule -
This variable represents the time offset (in minutes), meaning:
the number of minutes that should be added for summer-time."
::= { schedXEntry 3 }
systemPort OBJECT IDENTIFIER ::= { agnt 15 }
physicalConnectorTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhysicalConnectorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes the connector type of ports or interfaces."
::= {systemPort 1}
physicalConnectorEntry OBJECT-TYPE
SYNTAX PhysicalConnectorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {portIdx}
::= { physicalConnectorTable 1 }
PhysicalConnectorEntry ::=
SEQUENCE {
portIdx
Integer32,
physicalConnector
INTEGER,
portOptWaveLength
INTEGER,
portOptMode
INTEGER,
portBalance
INTEGER,
portDdmSupport
INTEGER,
portMfgName
SnmpAdminString,
portTypicalMaxRange
Unsigned32,
physicalConnectorString
SnmpAdminString,
portVendorPartNo
SnmpAdminString
}
portIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is an index of the specific port or interface.
For a port, the index will be as agreed between agent and
application.
For an interface, ifIndex may be used."
::= { physicalConnectorEntry 1 }
physicalConnector OBJECT-TYPE
SYNTAX INTEGER
{
other (1),
v35 (2), --34 pin female
rs530 (3), --DB25
x21 (4), --DB15
bnc (5),
utp (6), --RJ45
aui (7),
rs422 (8), --DB25
crossUtp (9), --RJ45
rj45 (10),
v24 (11), --DB25
g703 (12), --TB5
termBlock3AndRj45 (13),
terminalBlock3 (14),
terminalBlock5 (15),
terminalBlock7 (16),
db25 (17),
db15 (18),
rj45ethernet (19),
termBlock5AndRj45 (20),
db9 (21),
g703E1 (22), --BNC-RJ45-BNC
g703E1-LTU (23), --BNC-RJ45-BNC
sc (24), --sc optical
st (25), --st optical
stl (26),
fc (27), --fc optical
tb5w (28), --Term-Block-5-Wire (for HCD)
termBlock6AndRj45 (29),
ethBnc (30),
scsi26 (31), --SCSI with 26 pins
eth4381 (32), --RJ45 with two embeded LEDs
twoBnc (33), --Two BNC
scsi50 (34), --SCSI with 50 pins
twoMiniBnc (35), --Two mini BNC
sf1 (36), --sf1=single fiber optical
terminalBlock4 (37),
sf2 (38), --sf2=single fiber optical
db25Balanced (39), --DB25 Balanced
v36 (40),
block4W (41), --like in WR connector for Modems
iripRj45 (42),
irEthQRj45 (43),
iripBnc (44),
rs530WA (45), --rs530/IR that solves a wander problem for SDH network
v35WA (46), --v35/IR that solves a wander problem for SDH network
irEthQBnc (47),
v35Db25 (48), --V.35 with connector DB25
rj11 (49), --Used for FXS & FXO
mtrj (50), --optical
lc (51), --optical
terminalBlock2 (52),
irEth10s100 (53), --IR-ETH 10/100
scsi68 (54), -- SCSI 68 pins
sf3 (55), -- sf3=single fiber of sc optical
fcLH (56), -- fc Long Haul
telco50 (57), -- TELCO 50
telco64 (58), -- TELCO 64
irEthQN (59),
terminalBlock6 (60),
scLH (61), -- sc Long Haul
stLH (62), -- st Long Haul
lcLH (63), -- lc Long Haul
sfpIn (64), -- SFP module is installed (In container)
sfpOut (65), -- SFP module is not installed (Out of container)
db44 (66), -- DB44 (High Density D-type)
db62 (67), -- DB62 (High Density D-type)
v24Db9 (68), -- V.24 with connector DB9
scsi40 (69), -- SCSI 40 pins
sf1NineRow (70), -- sf1 9-row
sf2NineRow (71), -- sf2 9-row
sf3NineRow (72), -- sf3 9-row
smartSerial26 (73), -- QDC1113L (Cisco)
miniUsb5 (74),
db26 (75), -- DB26 (High Density D-Type)
comboUtpSfpIn (76), -- UTP+SFP combo, SFP module is installed
comboUtpSfpOut (77), -- UTP+SFP combo, SFP module is not installed
none (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The connector of the port/interface.
other - none of the specified connectors
none - no connector."
::= { physicalConnectorEntry 2 }
portOptWaveLength OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
nm850(2),
nm1310(3),
nm1310Laser(4),
nm1550Laser(5),
nm1470Laser(6),
nm1490Laser(7),
nm1510Laser(8),
nm1530Laser(9),
nm1570Laser(10),
nm1590Laser(11),
nm1610Laser(12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wave Length of an Optical interface/port in [nm] and specification if
Laser or not.
notApplicable - for non-optical ports."
::= { physicalConnectorEntry 3 }
portOptMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
singleMode(2),
multiMode(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Mode of an Optical Laser interface/port.
notApplicable - for non-Laser ports."
::= { physicalConnectorEntry 4 }
portBalance OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
unbalanced (2),
balanced (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is according to the port Impedance.
For T1 - always balanced.
For E1 - there are different impedance values for balanced
and unbalanced."
::= { physicalConnectorEntry 5 }
portDdmSupport OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SFP (Small Form Pluggable) port -support
Digital Diagnostics Monitoring."
::= { physicalConnectorEntry 6 }
portMfgName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"(SFP) Port Manufacturer name
(Maximum - 16 characters)."
::= { physicalConnectorEntry 7 }
portTypicalMaxRange OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum range supported by SFP port,
in meter units."
::= { physicalConnectorEntry 8 }
physicalConnectorString OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"(SFP) connector type. It can be Vendor Specific
(unknown in advance). Being a string, the object is not
affected by any future new connectors.
This object will usually not be used
for drawing the connector."
::= { physicalConnectorEntry 9 }
portVendorPartNo OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SFP Vendor Part Number. Being a string, the object is not
affected by any future new SFPs."
::= { physicalConnectorEntry 10 }
prtSupervisory OBJECT IDENTIFIER ::= { systemPort 2 }
prtSpTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= {prtSupervisory 1}
prtSpEntry OBJECT-TYPE
SYNTAX PrtSpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Supervisory port parameter table."
INDEX {prtSupervisoryIndex }
::= { prtSpTable 1}
PrtSpEntry ::=
SEQUENCE {
prtSupervisoryIndex Integer32,
prtSupervisoryRate INTEGER,
prtSupervisoryDataBits INTEGER,
prtSupervisoryParity INTEGER,
prtSupervisoryStopBits INTEGER,
prtSupervisoryUsage INTEGER,
prtSupervisoryInterface INTEGER,
prtSupervisoryCTS INTEGER,
prtSupervisoryDcdDelay INTEGER,
prtSupervisoryDSR INTEGER,
prtSupervisoryRoutProtocol INTEGER
}
prtSupervisoryIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SP port index.
For some products, having modules (cards):
The LS byte of the integer is the port index 1..255.
The MS byte is different than 0 only if the port belongs to
a module. In that case it is the module number.
For other products' index see their specification."
::= { prtSpEntry 1}
prtSupervisoryRate OBJECT-TYPE
SYNTAX INTEGER
{
auto (1),
s300bps (2),
s1200bps (3),
s2400bps (4),
s4800bps (5),
s9600bps (6),
s19200bps (7),
s38400bps (8),
s57600bps (9),
s115200bps (10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the operation rate (speed) of the
port.
auto - automatic rate selection, by the agent."
::= { prtSpEntry 2}
prtSupervisoryDataBits OBJECT-TYPE
SYNTAX INTEGER
{
dataBits7 (1),
dataBits8 (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the number of data bits in an async
frame"
::= { prtSpEntry 3}
prtSupervisoryParity OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
odd (2),
even (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the parity mode in an async frame"
::= { prtSpEntry 4}
prtSupervisoryStopBits OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
stopBits1 (2),
stopBits1dot5 (3),
stopBits2 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the parity mode in an async frame."
::= { prtSpEntry 5}
prtSupervisoryUsage OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
noUse (2),
terminal(3),
nmsSlip (4),
nmsPpp (5),
muxSlip (6),
muxPpp (7),
dialOut (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the usage of the SP port."
::= { prtSpEntry 6}
prtSupervisoryInterface OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
dce (2),
dte (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the supervisory port interface."
::= { prtSpEntry 7}
prtSupervisoryCTS OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
on (2), --Old value for DCE.
rts (3), --Old value for DCE
dteWait (4), --DTE will wait for CTS to become active before transmit date.
dteIgnore (5) --DTE will Ignore CTS signal and will transmit date anyway.
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CTS line state."
::= { prtSpEntry 8}
prtSupervisoryDcdDelay OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
d0 (2),
d10 (3),
d50 (4),
d100 (5),
d200 (6),
d300 (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DCD delay in msec."
::= { prtSpEntry 9}
prtSupervisoryDSR OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
on (2),
dtr (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DSR line state."
::= { prtSpEntry 10}
prtSupervisoryRoutProtocol OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
proprietary (3),
rip2 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the routing protocol of the port.
notApplicable - for DP."
::= { prtSpEntry 11}
--Port Performance Data
prtPerformance OBJECT IDENTIFIER ::= { systemPort 3 }
prtPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes G.826 ports or interfaces."
::= {prtPerformance 1}
prtPerfEntry OBJECT-TYPE
SYNTAX PrtPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtPerfIdx, prtPerfPeriodRef}
::= { prtPerfTable 1 }
PrtPerfEntry ::=
SEQUENCE {
prtPerfIdx
Integer32,
prtPerfPeriodRef
INTEGER,
prtPerfElapsedTime
Integer32,
prtPerfUAS
Integer32,
prtPerfES
Integer32,
prtPerfSES
Integer32,
prtPerfBBE
Integer32,
prtPerfBlocksPerSec
Integer32,
prtPerfTimeTag
TimeTicks,
prtPerfSaveAndResetCmd
INTEGER
}
prtPerfIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is an index of the specific port or interface.
For a port, the index will be as agreed between agent and
application.
For an interface, ifIndex may be used."
::= { prtPerfEntry 1 }
prtPerfPeriodRef OBJECT-TYPE
SYNTAX INTEGER
{
currentPeriod (1),
lastPeriod (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is an index that specifies which period of time, the next
5 objects refer to.
currentPeriod - the period since last prtPerfSaveAndResetCmd received or
since Start-up (if no prtPerfSaveAndResetCmd was received since
Start-up) until now.
lastPeriod - the period between last two commands of prtPerfSaveAndResetCmd.
- If only one command occured since Start-up: the period between
Start-up and last command.
- If no command occured since Start-up: this period will not
actually exist. In this case, he following 5 objects will be 0."
::= { prtPerfEntry 2 }
prtPerfElapsedTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed Time in seconds.
- for prtPerfPeriodRef=currentPeriod:
The period since last prtPerfSaveAndResetCmd received or since Start-up
(if no prtPerfSaveAndResetCmd was received since Start-up) until now.
- for prtPerfPeriodRef=lastPeriod:
The value of prtPerfElapsedTime when last prtPerfSaveAndResetCmd
was received."
::= { prtPerfEntry 3 }
prtPerfUAS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Unavailable Seconds for the reference period (prtPerfPeriodRef)."
::= { prtPerfEntry 4 }
prtPerfES OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Errored Seconds for the reference period (prtPerfPeriodRef)."
::= { prtPerfEntry 5 }
prtPerfSES OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Severely Errored Seconds for the reference period (prtPerfPeriodRef)."
::= { prtPerfEntry 6 }
prtPerfBBE OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Background Block (or Frame) Errors for the reference period
(prtPerfPeriodRef)."
::= { prtPerfEntry 7 }
prtPerfBlocksPerSec OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Blocks per second (or frames per second) of the port/interface indicated by
portIdx. This object is constant for a certain port/interface.
It is not affected by the prtPerfPeriodRef index."
::= { prtPerfEntry 8 }
prtPerfTimeTag OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time Tag of Last Period: sysUpTime when last prtPerfSaveAndResetCmd was
executed.
This object is applicable only for prtPerfPeriodRef=lastPeriod.
For prtPerfPeriodRef=currentPeriod, the value will always be 0."
::= { prtPerfEntry 9 }
prtPerfSaveAndResetCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A command per port/interface, to Save data of Current Period in Last Period
data-set and start a new counting period for Current Period.
This object is applicable only for prtPerfPeriodRef=currentPeriod.
Setting this object to on(3) for prtPerfPeriodRef=last, will cause the agent
to return: Bad Value response.
When setting validly this object to on(3), agent will perform the required
command and will reset automatically the value of this object to off(2).
Setting this object to off(2), will do nothing."
::= { prtPerfEntry 10 }
--Port Test Data
prtTest OBJECT IDENTIFIER ::= { systemPort 4 }
prtTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes test data for ports or interfaces."
::= {prtTest 1}
prtTestEntry OBJECT-TYPE
SYNTAX PrtTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtTestIdx}
::= { prtTestTable 1 }
PrtTestEntry ::=
SEQUENCE {
prtTestIdx
Integer32,
prtTestCmdAndStatus
Integer32,
prtBertCounter
Integer32,
prtTestInitiator
INTEGER,
prtTestTimeout
Integer32,
prtTestVctRxResult
INTEGER,
prtTestVctTxResult
INTEGER,
prtTestVctRxDistance
Integer32,
prtTestVctTxDistance
Integer32,
prtTestVctCmd
INTEGER,
prtTestVctRxCrossPair
Integer32,
prtTestVctTxCrossPair
Integer32,
prtTestActivationDelay
Unsigned32,
prtTestMacSwapLoopDataMode
INTEGER,
prtTestMacSwapLoopVlanId
Integer32,
prtTestMacSwapLoopDirection
INTEGER,
prtTestMacSwapLoopDestAddr
MacAddress,
prtTestMacSwapLoopSrcAddr
MacAddress,
prtTestOamMinRoundTripDelay
Unsigned32,
prtTestOamMaxRoundTripDelay
Unsigned32,
prtTestOamAvgRoundTripDelay
Unsigned32,
prtTestOamTxInterval
Unsigned32,
prtTestDestinationIpAddress
IpAddress,
prtTestForceTTL
Unsigned32,
prtTestBwProfile
Unsigned32,
prtTestSourceIpAddress
IpAddress,
prtTestRemainTime
Unsigned32
}
prtTestIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is an index of the specific port or interface.
For a port, the index will be as agreed between agent and
application.
For an interface, ifIndex may be used."
::= { prtTestEntry 1 }
prtTestCmdAndStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to a value as detailed further on
(except 0) will initiate a test on the specific port.
The test/s requested will be set according to the respective
bit. The value of this object will be a sum of (2**n), where n is
the Bit:
TEST BIT VALUE
----------- --- ------
reserved 0 1
PayloadLoop=RLB 1 (=Remote Loopback) 2
LineLoop=DIG 2 (=Digital) 4
OtherLoop 3 8
InwardLoop=LLB 4 (=Local Loopback) 16
BERT 5 32
LC 6 64
ToneInjection 7 128
Inband 8 256
BERT Remote (or E1/T1 RLB) 9 512
Downstream-AIS (or E1/T1 LLB) 10 1024
Upstream-AIS 11 2048
Rem-Loop-on-Rem-Unit 12 4096
MacSwapLoop 13 8192
OamETHLoopback 14 16384
OamETHLinkTrace 15 32768
IPSwapLoop 16 65536
e.g : If the requested value is 20 -> 010100 ->
Bits 2 & 4 are set -> the requested tests are :
LineLoopback=DIG
InwardLoopback=LLB
Not all tests combinations are valid.
For valid test combination, see each product's specification.
For LRS52, only single test is allowed simultaneously
The terminology and order of the first tests (except BERT)
is according to the one used for Test Status of DS1 and DS3 standards.
The notations : RLB, LLB, DIG are the most used in RAD's products, but they
can be different. For exact definition see product's spec.
Setting this object to stop (value=0 ; all bits are 0),
will stop all the user requested tests running on the
selected port.
When no test is running on the port, the Get value (test status)
will be 0.
PayloadLoop=RLB
The received signal at this interface is looped
through the device. Typically the received signal
is looped back for retransmission after it has
passed through the device's framing function.
LineLoop=DIG
The received signal at this interface does not
go through the device (minimum penetration) but
is looped back out.
OtherLoop
Loopbacks that are not defined here.
InwardLoop=LLB
The sent signal at this interface is looped back
through the device.
LC
This loop is applicable only for HSSI interface, towards the router .
ToneInjection
This loop is applicable for analog voice (like FXS).
Downstream-AIS
E1 AIS signal (all ones) is transmitted in the relevant channel
toward the STM-1 line.
Upstream-AIS
E1 AIS signal (all ones) is generated in the relevant channel
toward the local received tributary channel output
Rem-Loop-on-Rem-Unit
Request from far end device to activate remote loopback
towards near-end device
MacSwapLoop
This loop is applicable for ethernet port. Loop is
implemented by swapping the MAC addresses of the
incoming message.
OamETHLoopback
Ethernet Loopback is used to verify connectivity of a MEP with a MIP
or peer MEP(s) (ITU-T Y.1731, Clause 7.2).
OamETHLinkTrace
Ethernet Link Trace is an on-demand OAM function which can be used for
the two following purposes:
- Adjacent Relation Retrieval
- Fault Localization
(ITU-T Y.1731, Clause 7.3).
IPSwapLoop
This loop is applicable for ethernet port. Loop is
implemented by swapping the IP addresses of the
incoming message.In ETX-202A, this test causes also swapping of
the the MAC address (bit 13 should also be set to 1).
"
::= { prtTestEntry 2 }
prtBertCounter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of BERT errors encountered
during the BERT operation.
It is valid only when BERT (Bit Error Rate Test) is active on the
specific port.
The Counter starts from zero (0) anytime BERT is initiated."
::= { prtTestEntry 3}
prtTestInitiator OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
user (2),
remoteUnit(3),
dteRouter (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates who initiated this port's test/s."
::= { prtTestEntry 4 }
prtTestTimeout OBJECT-TYPE
SYNTAX Integer32 (0..86400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only when a single
test is running. It indicates the test
activation timeout in minutes.
For RICi-E1T1, RICi-E3T3 and LRS-16, the measurement
unit is in seconds.
When the timeout expires, the test is stopped.
Value of 0 indicates test may run Forever "
::= { prtTestEntry 5 }
prtTestVctRxResult OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
fail (2),
normal (3),
open (4),
short (5),
shortToCrossPair (6),
coupleWithCrossPair (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the result of the Vct on
the cable connected to the RX connector."
::= { prtTestEntry 6 }
prtTestVctTxResult OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
fail (2),
normal (3),
open (4),
short (5),
shortToCrossPair (6),
coupleWithCrossPair (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the result of the Vct on
the cable connected to the TX connector."
::= { prtTestEntry 7 }
prtTestVctRxDistance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the distance in Meters
to the RX cable Open/ Short location discovered by the Vct.
This parameter is applicable for Vct Result = Normal or Fail only,
Else the value of this parameter will be equal to 0."
::= { prtTestEntry 8 }
prtTestVctTxDistance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the distance in Meters
to the TX cable Open/ Short location discovered by the Vct.
This parameter is applicable for Vct Result = Normal or Fail only,
Else the value of this parameter will be equal to 0."
::= { prtTestEntry 9 }
prtTestVctCmd OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Vct command.
on (3) = Start Vct on both cables connected to
RX and TX connectors of this port.
Agent will perform the required command and change automatically
the value of this object to off(2)."
::= { prtTestEntry 10 }
prtTestVctRxCrossPair OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object should be equal to the Index (prtTestIdx) of the Rx cross pair.
This object is applicable only for Vct Result = shortToCrossPair or coupleWithCrossPair.
This object was especially created for ETX-202. Currently not in use."
::= { prtTestEntry 11 }
prtTestVctTxCrossPair OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object should be equal to the Index (prtTestIdx) of the Tx cross pair.
This object is applicable only for Vct Result = shortToCrossPair or coupleWithCrossPair."
::= { prtTestEntry 12 }
prtTestActivationDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only when a single test is running.
It indicates test activation delay in seconds.
A Value of 0 indicates that the test starts immediately."
::= { prtTestEntry 13 }
prtTestMacSwapLoopDataMode OBJECT-TYPE
SYNTAX INTEGER
{
all (1),
allExceptMng (2),
specificVlan (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines which part
of the data will be looped back."
::= { prtTestEntry 14 }
prtTestMacSwapLoopVlanId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the VLAN ID for
prtTestMacSwapLoopDataMode=specificVlan."
::= { prtTestEntry 15 }
prtTestMacSwapLoopDirection OBJECT-TYPE
SYNTAX INTEGER
{
local (2),
remote (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the direction of the performed loopback.
In ETX102 'local' corresponds to Ingress loop
(either on User port or on Network port), and
'remote' corresponds to Egress loop
(either on User port or on Network port)."
::= { prtTestEntry 16 }
prtTestMacSwapLoopDestAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the MAC address that will be sent in the
Destination field of the packet in the outgoing direction. "
::= { prtTestEntry 17 }
prtTestMacSwapLoopSrcAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the MAC address that will be sent in the
Source field of the packet in the outgoing direction. "
::= { prtTestEntry 18 }
prtTestOamMinRoundTripDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mininal value of round trip delay of loopback message for a session of
OAM loopback.Units are msec."
::= { prtTestEntry 19 }
prtTestOamMaxRoundTripDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum value of round trip delay of loopback message for a session of
OAM loopback.Units are msec."
::= { prtTestEntry 20 }
prtTestOamAvgRoundTripDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average round trip delay of loopback message for a session of
OAM loopback.Units are msec."
::= { prtTestEntry 21 }
prtTestOamTxInterval OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the interval between loopback sent messages.Units are msec."
::= { prtTestEntry 22 }
prtTestDestinationIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the destination IP Address in the transmitted messages that
are looped back."
::= { prtTestEntry 23 }
prtTestForceTTL OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time-to-live.Number of hops the loopback message will go through the net
before deciding to discard it."
::= { prtTestEntry 24 }
prtTestBwProfile OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Indicates the BW profile (from bwProfileTable) that is assigned to the loopback test
in order to limit the traffic that is looped back."
::= { prtTestEntry 25 }
prtTestSourceIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the source IP Address in the transmitted messages that
are looped back."
::= { prtTestEntry 26 }
prtTestRemainTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the remain time for test activation
in seconds."
::= { prtTestEntry 27 }
--Port General Parameters
prtParam OBJECT IDENTIFIER ::= { systemPort 5 }
prtParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes general port parameters. The meaning is
different for every product that supports it due to a general
parameter - prtControlCnfg.
For ACE2002:
-This table is used as a mechanism to create the next interface index.
The algorithm description:
The NMS will send the agent the following get command: get(nextIfIndex.index),
where index=interface on which the new index is dependent on.
Upon this command the agent will generate and return the new index to the NMS.
- This table is partially supported according to the interface type.
Upon getNext function the irrelevant parameters will be skipped."
::= {prtParam 1}
prtParamEntry OBJECT-TYPE
SYNTAX PrtParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtParamIdx}
::= { prtParamTable 1 }
PrtParamEntry ::=
SEQUENCE {
prtParamIdx Integer32,
prtControlCnfg Integer32,
prtParamClkSrc INTEGER,
prtParamPhantom INTEGER,
prtParamResetStatsCmd INTEGER,
prtParamLastResetStatsTime TimeStamp,
prtParamInterfaceType INTEGER,
prtParamClearAlarm INTEGER,
prtParamLeds OCTET STRING,
prtParamLineLength INTEGER,
prtParamUsage INTEGER,
prtParamMappingMode INTEGER,
prtParamAlarmIndication INTEGER,
prtParamClkQualityLevel OCTET STRING,
prtParamClkWaveShape INTEGER,
prtParamStatus INTEGER,
prtParamSignalLevel Integer32,
prtParamClkUserQualityLevel OCTET STRING,
prtParamDataRate Unsigned32,
prtParamLoopDetect INTEGER,
prtParamActUponLoopDetect OCTET STRING,
prtParamPSNLayer INTEGER,
prtParamRxSsm INTEGER,
prtParamClkSsmRxSource INTEGER,
prtParamFarEndDevice Unsigned32,
prtParamTxClk INTEGER,
prtParamSdBerThreshold Unsigned32,
prtParamLoopDetectStatus INTEGER
}
prtParamIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is an index of the specific port or interface.
For a port, the index will be as agreed between agent and
application.
For an interface, ifIndex may be used.
For ACE2002:
This parameter is the physical layer ifIndex of the slot on
which the NMS requires the next interface index."
::= { prtParamEntry 1 }
prtControlCnfg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object may be used for port RW general parameter/s.
For detailed meaning, see product's spec.
Supported by: PRBi-E3/T3.
For ACE2002:
This parameter will include the value of the new index
generated by agent.
For Optimux-T3 and OP-155-1:
This parameter will be used for Release Remote LLB Command:
on=2= Set value only. Command to release LLB of Remote Unit.
Agent will return automatically to 'off' value after performing
the command.
off=3=Get value only.
For LA140
This parameter will be used as EchoCanceler per timeslot
off = 2 Echo Canceler is disabled
on = 3 Echo Canceler is enabled
For FCD-155
This parameter will be used to select the port that is
clock source for a PDH port,
For E1/T1 PDH
VC12/VT1.5 = 2
SDH/SONET = 3
For E3/T3 PDH
VC3/DS3 = 2
SDH/SONET = 3
For ACE-52
This parameter will be used as Transmit Frame Type, i.e.
which type of frame the corresponding bridge port will transmit:
Untagged = 2
Tagged = 3
."
::= { prtParamEntry 2 }
prtParamClkSrc OBJECT-TYPE
SYNTAX INTEGER {
loopTiming (1),
localTiming (2),
throughTiming (3),
adaptive (4),
master (5),
fallback (6),
station (7),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The source of Transmit Clock.
'loopTiming' or 'loopback' indicates that the recovered receive clock
is used as the transmit clock.
'localTiming' or 'internal' indicates that a local clock
source is used or when an external clock is
attached to the box containing the interface.
'throughTiming' or 'external' indicates that recovered receive clock
from another card or interface is used as the transmit clock.
'adaptive' indicates that the clock is recovered according
to the received data flow rate.
'master' and 'fallback' values may be used RO to
indicate active clock.
'station' - indicate clock received from station
port is used as transmit clock."
::= { prtParamEntry 3 }
prtParamPhantom OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Power feeding to another device."
::= { prtParamEntry 4 }
prtParamResetStatsCmd OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset statistics of the selected port."
::= { prtParamEntry 5 }
prtParamLastResetStatsTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of MIB II's sysUpTime object at the last time that
prtParamResetStatsCmd was Set to on(3) for this port.
If prtParamResetStatsCmd was never Set to on(3) since last
re-initialization of the agent, then this object contains a zero value.
This object enables calculating the running time of Statistics
counters for this port, by: [sysUpTime-prtParamLastResetStatsTime].
For some devices other types of 'Reset' may affect this parameter"
::= { prtParamEntry 6 }
prtParamInterfaceType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
e1 (2),
t1 (3),
fr (4),
hdlc (5),
hdsl2 (6),
shdsl (7),
adsl (8),
adsl2 (9),
reAdsl2 (10),
mPair (11),
efm (12), --64-65 Octets
atmIma (13),
ds1 (14)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of the port."
::= { prtParamEntry 7 }
prtParamClearAlarm OBJECT-TYPE
SYNTAX INTEGER {
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON, will enforce a clear
operation on the Port Alarms.
Upon completion, the value will automatically change
to off(2)."
::= { prtParamEntry 8 }
prtParamLeds OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the LEDs status of the port.
Each led is represented by 4 bits where the first 2 bits
(left) specify the status :
(00=NA, 01=OFF, 10=ON, 11=BLINK),
and the next two bits (right) specify the color :
(00=GREEN, 01=RED, 10=YELLOW, 11=GRAY).
The order of the LEDS is from top to bottom, left to right:
For each row starting from the top,
the LEDS are returned from left to right."
::= {prtParamEntry 9}
prtParamLineLength OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
long (2),
normal (3),
short (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Line Length of the line connected to this port."
::= { prtParamEntry 10 }
prtParamUsage OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
user (2),
network (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines whether this port works as User port or as Network port."
::= { prtParamEntry 11 }
prtParamMappingMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off (2),
auto (3),
manual (4),
adjacent (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines path protection on SONET/SDH link
Auto - SONET/SDH mapping for port is copied
automatically to same TU on the redundant
SONET/SDH local (reside on same slot) link by agent.
Manual - the user can configure the redundant
mapping for port on the same link
or to the other link on any TU
Adjacent - similar to auto, but mapping is copied
automatically by agent to link on adjacent slot ."
::= { prtParamEntry 12}
prtParamAlarmIndication OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
off (2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates status-aggregation of non-masked alarms
associated with all interface layers, related to this physical port.
When at least one non-masked alarm exists on any layer,
value of this object is on (3).
Indication will be off (2) only when there's no active
non-masked alarm on any interface layer related to this port.
Masking an Alarm, will consider it as not exist for this indication.
Example: When a port has an ATM higher layer and at least
one VC has alarm, value of this object will be on (3)"
::= {prtParamEntry 13}
prtParamClkQualityLevel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates quality level of clock signal.
Quality is encoded according to SSM
(Synchronization Status Messages) encoding.
Bits 8 -5 of byte are encoded as follows (when bit1=0):
Left most bit - MSB(8) ---> LSB(5)
8765
0000 Quality Unknown
0010 PRC (Primary Reference Clock) - Rec. G.811
0100 SSU-T (Sync. Source Unit-Transit)- Rec. G.812 Transit
1000 SSU-L (Sync. Source Unit Local) - Rec. G.812 Local
1011 SEC (SDH Equipment Clock)
1111 DNU (do not use for synchronization)
0001 PRS (=ST1 = Stratum 1 Traceable)
0111 ST2 (Stratum 2 Traceable)
1010 ST3 (Stratum 3 Traceable)
1100 SMC (SONET Minimum Clock Traceable)
1101 Stratum 3E Traceable
bit1 = '1' - indicates all octet is Not Applicable"
::= {prtParamEntry 14}
prtParamClkWaveShape OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
sine (2),
square (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Wave shape of station clock source signal."
::= { prtParamEntry 15 }
prtParamStatus OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
up (2),
signalLoss (3),
syncLoss (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Station clock source Status."
::= { prtParamEntry 16 }
prtParamSignalLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates signal level (in thenth of dB units)
on selected port."
::= { prtParamEntry 17 }
prtParamClkUserQualityLevel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter allows user to mark quality level of clock.
Quality is encoded according to SSM
(Synchronization Status Messages) encoding.
Bits 8 -5 of byte are encoded as follows:
Left most bit - MSB(8) ---> LSB(5)
8765
0000 Quality Unknown
0010 PRC (Primary Reference Clock) - Rec. G.811
0100 SSU-T (Sync. Source Unit-Transit) Rec. G.812 Transit
1000 SSU-L (Sync. Source Unit Local) - Rec. G.812 Local
1011 SEC (SDH Equipment Clock)
1111 DNU (do not use for synchronization)"
::= {prtParamEntry 18}
prtParamDataRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Rate of serial data port (V.11, V.24, V.35)
in kbps units."
::= { prtParamEntry 19}
prtParamLoopDetect OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable Loop Detection on a port.
Examples of ports: physical, Channelized Bundle over TDM Uplink,
Bridge Ports."
::= { prtParamEntry 20 }
prtParamActUponLoopDetect OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is used to indicate which actions
should be taken in case a loop is detected in the network the port is part of.
Each action is represented by a bit.
Currently defined (for RIC155GE/RIC622GE):
Bit 0 - Transmit Shut Down
Bit 1 - Forward Alarms
If bit value = '1' then the action is taken.
If bit value = '0' then the actions is not taken."
::= { prtParamEntry 21 }
prtParamPSNLayer OBJECT-TYPE
SYNTAX INTEGER
{
l2 (2), -- lan
l3 (3) -- wan
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the network layer from which clock is derived."
::= { prtParamEntry 22 }
prtParamRxSsm OBJECT-TYPE
SYNTAX INTEGER
{
disabled (2),
rx (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if Station Clock SSM messages
received will serve as criteria for clock selection."
::= { prtParamEntry 23 }
prtParamClkSsmRxSource OBJECT-TYPE
SYNTAX INTEGER
{
sa4 (2),
sa5 (3),
sa6 (4),
sa7 (5),
sa8 (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Sa-bit of the E1 frame,
in which SSM messages are carried."
::= { prtParamEntry 24 }
-- ::= { prtParamEntry 25 } reserved
prtParamFarEndDevice OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Programmed Far-End device connected to this port.
This object is relevant for products having multiple DBs.
It will enable configuring offline, the relevant data.
For MP-4100, LRS-102 OP-108/106 cards, the options will be:
1 = None (when a port is not connected to any remote device)
2 = OP-108
3 = OP-108/ETH
4 = OP-106
5 = OP-106/ETH
6 = card of MP or LRS-102"
::= { prtParamEntry 26}
prtParamTxClk OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"enable/disable station clock signal output."
::= { prtParamEntry 27 }
prtParamSdBerThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..9)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Signal Degrade Bit Error Rate Threshold.
The negated value of this number is used as the exponent of
10 for computing the threshold value for the Bit Error Rate (BER).
For example, a value of 5 indicates a BER threshold of 10^-5.
For disabling the signal degradation, the value will be: 0"
::= { prtParamEntry 28 }
prtParamLoopDetectStatus OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
noLoop (2),
loopDetected (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows whether a loop was detected on the current port."
::= { prtParamEntry 29 }
prtIP OBJECT IDENTIFIER ::= { systemPort 6 }
prtIpParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtIpParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table - Parameters for IP Ports."
::= {prtIP 1}
prtIpParamEntry OBJECT-TYPE
SYNTAX PrtIpParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtIpParamConfigIdx, prtIpParamSlotIdx, prtIpParamIdx }
::= { prtIpParamTable 1 }
PrtIpParamEntry ::=
SEQUENCE {
prtIpParamConfigIdx Integer32,
prtIpParamSlotIdx Integer32,
prtIpParamIdx Integer32,
prtIpParamHostIP IpAddress,
prtIpParamHostMask IpAddress,
prtIpParamDefaultGateway IpAddress,
prtIpParamMediaMode INTEGER,
prtIpParamMediaRate INTEGER,
prtIpParamMngVlanSupport INTEGER,
prtIpParamMngVlanId Integer32,
prtIpParamMngVlanPriority Integer32,
prtIpParamRingMode INTEGER,
prtIpParamProtIpEnable INTEGER,
prtIpParamTrafficPriority INTEGER,
prtIpParamRemoteIP IpAddress,
prtIpParamMaxTxBandwidth INTEGER,
prtIpParamTos Integer32,
prtIpParamConnect INTEGER,
prtIpParamAgingTime Integer32,
prtIpParamEncapsulationProt INTEGER,
prtIpParamEncapProtPort Integer32,
prtIpParamVlanSupport INTEGER,
prtIpParamVlanId Integer32,
prtIpParamVlanPriority Integer32,
prtIpParamDoubleTagVlanId Integer32,
prtIpParamDoubleTagVlanPriority Integer32,
prtIpParamVlanTagging INTEGER,
prtIpParamRateLimit Integer32,
prtIpParamDefInterface Integer32,
prtIpParamMng INTEGER,
prtIpParamFloodedRateLimit Integer32,
prtIpParamBurstSize Unsigned32,
prtIpParamLimitPacketType INTEGER,
prtIpParamKeepAliveInterval Integer32,
prtIpParamKeepAliveThresh Integer32,
prtIpParamP2pKeepAliveVlanId Integer32,
prtIpParamP2pKeepAliveVlanPrio Integer32,
prtIpParamRingAdjacentMacAddr MacAddress
}
prtIpParamConfigIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Configuration number (1..255)
referred.
Value of 255 specifies the TmpCnfg (Scratch).
For products having Agent and Edit configurations,
Write operation for the table entries is allowed only to
Config=255."
::= { prtIpParamEntry 1 }
prtIpParamSlotIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique number of the slot position
in which the module is inserted.
notApplicable = 255 (for products that don't have slots).
For KM:
kmxMlA (103),
kmxMlB (104)."
::= { prtIpParamEntry 2 }
prtIpParamIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique Port Index."
::= { prtIpParamEntry 3 }
prtIpParamHostIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The host interface IP address."
::= { prtIpParamEntry 4 }
prtIpParamHostMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The host interface subnet mask."
::= { prtIpParamEntry 5 }
prtIpParamDefaultGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default Gateway's IP Address."
::= { prtIpParamEntry 6 }
prtIpParamMediaMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
halfDuplex (2),
fullDuplex (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the real Media Mode."
::= { prtIpParamEntry 7 }
prtIpParamMediaRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
r10Mbps (2),
r100Mbps (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the real Media Rate (Mbps)."
::= { prtIpParamEntry 8 }
prtIpParamMngVlanSupport OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Management VLAN support (Tagging).
no - No support of VLAN Tagging.
yes - 4 VLAN bytes will be added to the frame."
::= { prtIpParamEntry 9 }
prtIpParamMngVlanId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Management VLAN ID."
::= { prtIpParamEntry 10 }
prtIpParamMngVlanPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Management VLAN Frame priority."
::= { prtIpParamEntry 11 }
prtIpParamRingMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates If Ring Mode is enabled or not."
::= { prtIpParamEntry 12 }
prtIpParamProtIpEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether a list of Protected IP Addresses
is enabled or not. This object is applicable only if
prtIpParamRingMode=enable."
::= { prtIpParamEntry 13 }
prtIpParamTrafficPriority OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
low (2),
high (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the traffic priority of this port."
::= { prtIpParamEntry 14 }
prtIpParamRemoteIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the IP Address of the remote device that is connected to the
current device (Point to Point Application). It is used for sending OAM packets
on the LAN to the remote side in order to check that the connection is OK."
::= { prtIpParamEntry 15 }
prtIpParamMaxTxBandwidth OBJECT-TYPE
SYNTAX INTEGER
{
full (2),
e1 (3),
t1 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object shows the Max Bandwidth allowed on the LAN.
Full - means that a Maximum of 100 Mega Byte Rate may go through the LAN.
e1(3) means that the maximum is an E1 rate. t1(4) is for a maximum of a T1 rate."
::= { prtIpParamEntry 16 }
prtIpParamTos OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TOS = Type of Service transmitted.
Valid values: 0..255."
::= { prtIpParamEntry 17 }
prtIpParamConnect OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Connection."
::= { prtIpParamEntry 18 }
prtIpParamAgingTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Aging Time in seconds."
::= { prtIpParamEntry 19 }
prtIpParamEncapsulationProt OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
tcp (2),
udp (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Encapsulation Protocol."
::= { prtIpParamEntry 20 }
prtIpParamEncapProtPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Encapsulation Protocol Port (TCP/UDP Port)."
::= { prtIpParamEntry 21 }
prtIpParamVlanSupport OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN support (Tagging).
'no' - No support of VLAN Tagging.
'yes' - 4 VLAN bytes will be added to the frame."
::= { prtIpParamEntry 22 }
prtIpParamVlanId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN Identifier."
::= { prtIpParamEntry 23 }
prtIpParamVlanPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN Frame priority."
::= { prtIpParamEntry 24 }
prtIpParamDoubleTagVlanId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN Identifier of the Double Tagging VLAN."
::= { prtIpParamEntry 25 }
prtIpParamDoubleTagVlanPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN Frame priority of the Double Tagging VLAN."
::= { prtIpParamEntry 26 }
prtIpParamVlanTagging OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
unmodified (2),
tag (3),
doubleTag (4),
doubleTagAndFallBack (5),
untag (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN Tagging.
'unmodified' - No change will be done to the Frame.
'tag' - Add Tag to Untagged Frames.
'doubleTag' - Add Tag to all Frames.
'doubleTagAndFallBack' - Double Tagging will have different rules for
VLANs that this port is member in, than these it is not a member in.
'untag' - Remove Tag from tagged frames."
::= { prtIpParamEntry 27 }
prtIpParamRateLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum rate permitted to transfer via this port, in Kbps."
::= { prtIpParamEntry 28 }
prtIpParamDefInterface OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Default Interface for packets with unresolved destination subnet.
For internal-X port: 100 + X ."
::= { prtIpParamEntry 29 }
prtIpParamMng OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether Management is enabled/disabled
via this port."
::= { prtIpParamEntry 30 }
prtIpParamFloodedRateLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum rate permitted to transfer broadcast, multicast,
and unicast flooded frames via this port, in Kbps.
0 - Disable.
In Ipmux14 this parameter is applicable when prtIpParamRateLimit=0 (disable)."
::= { prtIpParamEntry 31 }
prtIpParamBurstSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The burst size that the port can support beyond rate limitation
determined in prtIpParamRateLimit.
Burst Size is measured in bytes."
::= { prtIpParamEntry 32 }
prtIpParamLimitPacketType OBJECT-TYPE
SYNTAX INTEGER
{
all (1),
broadMultiFloodedUnicast (2),
broadcastMulticast (3),
broadcast (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The packet type that will be rate limited. Rate limitation
determined in prtIpParamRateLimit.
all - All packet types are rate limited.
broadMultiFloodedUnicast - Broadcast, Multicast and Flooded Unicast packets are rate limited.
broadcastMulticast - Broadcast and Multicast packets are rate limited.
broadcast - Broadcast packets are rate limited."
::= { prtIpParamEntry 33 }
prtIpParamKeepAliveInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the period of time (in msec.)
between two consequent Keep Alive messages."
::= { prtIpParamEntry 34 }
prtIpParamKeepAliveThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the maximum number of
missed Keep Alive answer messages acceptable, after which link status will be failed."
::= { prtIpParamEntry 35 }
prtIpParamP2pKeepAliveVlanId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Dedicated VLAN ID for keep alive messages."
::= { prtIpParamEntry 36 }
prtIpParamP2pKeepAliveVlanPrio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN priority for P2P keep alive messages ."
::= { prtIpParamEntry 37 }
prtIpParamRingAdjacentMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC address of the adjacent NE connected to this port in an ETH ring.
If the port is not a member of a ring, the value of this parameter
will be 00-00-00-00-00-00."
::= { prtIpParamEntry 38 }
prtClkSrc OBJECT IDENTIFIER ::= { systemPort 7 }
prtClkSrcTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtClkSrcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table - Parameters for master and fallback
clock source of ports ."
::= {prtClkSrc 1}
prtClkSrcEntry OBJECT-TYPE
SYNTAX PrtClkSrcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtClkSrcCnfgIdx, prtClkSrcPrtIdx, prtClkSrcIdx}
::= { prtClkSrcTable 1}
PrtClkSrcEntry ::=
SEQUENCE {
prtClkSrcCnfgIdx Integer32,
prtClkSrcPrtIdx Integer32,
prtClkSrcIdx INTEGER,
prtClkSrcMode INTEGER,
prtClkSrcPrt Integer32
}
prtClkSrcCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg(1..255) being
accessed ; Idx of 255 relates to the TmpCnfg."
::= { prtClkSrcEntry 1}
prtClkSrcPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates a unique Port Index (receiving clock).
Refer to device specification for port Index"
::= { prtClkSrcEntry 2}
prtClkSrcIdx OBJECT-TYPE
SYNTAX INTEGER
{
master (1),
fallback (2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index in the table.
master - refers Master clock parameters
fallback - refers Fallback clock parameters"
::= { prtClkSrcEntry 3}
prtClkSrcMode OBJECT-TYPE
SYNTAX INTEGER
{
-- none (1),
internal (2),
rxClk (3),
-- station (4),
-- lbt (5),
-- ntr (6),
-- adaptive (7),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates the source the nodal timing is
locked to."
::= { prtClkSrcEntry 4}
prtClkSrcPrt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry is valid only when working in rxClk mode.
It specifies the port from which the clock willl be taken.
Refer to device specification for source port Index"
::= { prtClkSrcEntry 5}
opticalPort OBJECT IDENTIFIER ::= { systemPort 8 }
optPrtMonitorTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptPrtMonitorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table - optical port (e.g SFP) monitoring parameters,
according to SFF-8472 Specification for Diagnostic Monitoring
Interface for Optical Xcvrs. and ITU-T rec. G.958"
::= {opticalPort 1}
optPrtMonitorEntry OBJECT-TYPE
SYNTAX OptPrtMonitorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {optPrtMonitorPrtIdx,optPrtMonitorSample}
::= { optPrtMonitorTable 1}
OptPrtMonitorEntry ::=
SEQUENCE {
optPrtMonitorPrtIdx Integer32,
optPrtMonitorSample INTEGER,
optPrtMonitorTxPower Integer32,
optPrtMonitorLaserBias Integer32,
optPrtMonitorLaserTemp Integer32,
optPrtMonitorRxPower Integer32,
optPrtMonitorSupplyVoltage Integer32
}
optPrtMonitorPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates a unique (optical) Port Index .
Refer to device specification for port Index."
::= { optPrtMonitorEntry 1}
optPrtMonitorSample OBJECT-TYPE
SYNTAX INTEGER {
actual (1),
minimum (2),
maximum (3)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This index indicates historic and current values -
minimum, maximum and actual (current) value. "
::= { optPrtMonitorEntry 2}
optPrtMonitorTxPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted optical power level.
Value is given in units of hundredth (1/100) of dBm. "
::= { optPrtMonitorEntry 3}
optPrtMonitorLaserBias OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LASER bias current level.
Value is given in units of microAmper (uA)."
::= { optPrtMonitorEntry 4}
optPrtMonitorLaserTemp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LASER temperature level,
in hundredth (1/100) (C) degrees."
::= { optPrtMonitorEntry 5}
optPrtMonitorRxPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received optical power in units of hundredth (1/100) of dBm. "
::= { optPrtMonitorEntry 6}
optPrtMonitorSupplyVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Supply voltage, in hundredth (1/100) of volts (V)."
::= { optPrtMonitorEntry 7}
optPrtCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptPrtCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table - optical port configuration"
::= {opticalPort 2}
optPrtCnfgEntry OBJECT-TYPE
SYNTAX OptPrtCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {optPrtCnfgIdx, optPrtCnfgPrtIdx}
::= { optPrtCnfgTable 1}
OptPrtCnfgEntry ::=
SEQUENCE {
optPrtCnfgIdx Unsigned32,
optPrtCnfgPrtIdx Unsigned32,
optPrtCnfgALS INTEGER
}
optPrtCnfgIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg(1..255) being
accessed ; Idx of 255 relates to the TmpCnfg.x."
::= { optPrtCnfgEntry 1}
optPrtCnfgPrtIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates a unique (optical) Port Index .
Refer to device specification for port Index."
::= { optPrtCnfgEntry 2}
optPrtCnfgALS OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"enable/disable Automatic Laser Shutdown "
::= { optPrtCnfgEntry 3}
systemResetAllStatsCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset statistics of all ports and connections of the device."
::= { agnt 16 }
systemClearTablesCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
tempCnfgTables (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"tempCnfgTables - Set *RowStatus = destroy for all entries of
some tables having *RowStatus object, for
temporary configuration only! (255).
For the relevant tables, see product's specification.
This object should be used by WAN product applications
before performing the Update operation, in order to clear
old entries of these tables.
For MP-104/204 the entries will be destroyed for cnfg=1.
off - agent will automatically change to this value, after performing the
command. "
::= { agnt 17 }
systemParameter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter can be used for different purposes:
- TELNET session time-out in seconds.
- Ace20: when trying to create row in a table that already
has row with the same values, if set of values has to be unique
in table, this attribute is set to the index of the existing row.
- Optimux-T3: when CH interfaces are RJ-45, user can select via this
object, the interface type for each Group of channels: T1 or E1:
The selection will be a sum of the following Bits.
'0' = T1
'1' = E1
Bit Group Value for each Bit having '1'
1 1 (CH-1..CH-8) 1
2 2 (CH-9..CH-12) 2
3 3 (CH-13..CH-20) 4
4 4 (CH-21..CH-28) 8
Examples:
15 = all Groups are selected to be E1
6 = Group 2 and Group 3 are selected to be E1
(Group 1 and Group 4 are T1).
- FCD-A, FCD-M: user can select via this object the configuration
used for Get values of MSDSL parameters that don't have
configuration index.
1 =active configuration
255=temporary configuration.
Set of this object should be done before Getting the MSDSL
RW parameters.
- Ace2002: This parameter indicates the number of intervals that
were successfully uploaded upon statistics collection session.
- FCD-IP, WR, FCD-IPD, LA-240:
This parameter indicates whether Telnet Access is enabled/disabled:
Values:
2 - Telnet Access is Disabled.
3 - Telnet Access is Enabled.
-Vmux-110: This parameter value equals to maximum number of bundles.
-Optimux-155: Simmilar usage to Optimux T3. user can select via this
object, interface type T1 or E1 for each Group of
channels (LIU): LIU group consists of 7 channels.
Up to 12 LIUs are represented (84 T1 Channels).
The selection will be a sum of the 2**n
For each bit:'0' = T1 ,'1' = E1
Bit Group
1 1 (CH-1 .. CH-7)
2 2 (CH-8 .. CH-14)
3 3 (CH-15 ..CH-21)
...
9 9 (CH-56.. CH-63)
...
10 10 (CH-64..CH-70)
11 11 (CH-71..CH-77)
12 12 (CH-78..CH-84) "
::= { agnt 18 }
agnGlobalAlarmMask OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this attribute determines the alarm traps the
agent should mask and not send to the managers.
Each bit from a certain octet represents a certain alarm."
::= { agnt 19 }
alarmSeverity OBJECT-TYPE
SYNTAX INTEGER
{
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the severity of the alarms."
::= { agnt 20 }
alarmState OBJECT-TYPE
SYNTAX INTEGER
{
off (2), -- End,
on (3) -- Start.
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"."
::= { agnt 21 }
agnTestStatus OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the current test status (for all levels: system,
card, port).
This attribute will be set to:
on(3): when there is at least one test in progress on the
system/card/port
off(2): when there is NO test in progress on the
system/card/port"
::= {agnt 22 }
systemSaveAndResetAllStatsCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"on - a command to Save data of Current Period in Last Period
data-set and start a new counting period for Current Period.
off - agent will automatically change to this value, after performing the
command."
::= { agnt 23 }
systemDefaultGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default Gateway's IP Address."
::= { agnt 24 }
-- PS Table
systemPsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SystemPsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes the PS types of a device.
Usage of this table is specified in the device's NMS SRS"
::= { agnt 25 }
systemPsEntry OBJECT-TYPE
SYNTAX SystemPsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {systemPsIndex1, systemPsIndex2}
::= { systemPsTable 1 }
SystemPsEntry ::=
SEQUENCE {
systemPsIndex1
Integer32,
systemPsIndex2
Integer32,
systemPsType
INTEGER,
systemPsStatus
INTEGER,
systemPsHotSwap
INTEGER
}
systemPsIndex1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"First Index.
In HUBs:
1 = PS-A slot
2 = PS-B slot
3 = PS-C slot.
In SA units:
1 = PS1
2 = PS2
Default = 1"
::= { systemPsEntry 1 }
systemPsIndex2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Second Index.
In HUBs:
1 always.
In SA units:
1 = Local
2 = Remote
Default = 1."
::= { systemPsEntry 2 }
systemPsType OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
ac (2),
dc (3),
acDc (4),
acPF (5),
dcPF (6),
acWithFan (7),
dcWithFan (8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of PS, for a stand-alone product.
acDc - PS that supports both AC and DC.
acPF - Power Feeding (phantom) box that is feeding another box by external AC.
dcPF - Power Feeding (phantom) box that is feeding another box by external DC.
acWithFan - AC PS with integrated FAN.
dcWithFan - DC PS with integrated FAN.
"
::= { systemPsEntry 3 }
systemPsStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
failed (2),
ok (3),
degraded (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Status of the PS unit."
::= { systemPsEntry 4 }
systemPsHotSwap OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
fixed (2),
hotSwap (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is PS unit hot swap or fixed."
::= { systemPsEntry 5 }
agnFans OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the FANs existence and status.
Each fan will be represented by 2 bits,
where the first bit (right) will specify the existence:
(0= Not exist, 1=exist),
and the left bit will specify it's status
(0= OK, 1=FAIL), so for each fan:
00 - FAN does not exist
01 - FAN exists and OK (Low Mode)
10 - High Mode (FAN OK)
11 - FAN exists and is Failed
bits 0-1 are for first fan
bits 2-3 are for 2nd fan (if exists)
bits 4-5 are for 3nd fan (if exists)
bits 6-7 are for 4nd fan (if exists)
bits 8-9 are for 5nd fan (if exists)
bits 10-11 are for 6nd fan (if exists)
bits 12-13 are for 7nd fan (if exists)
bits 14-15 are for 8nd fan (if exists)."
::= { agnt 26 }
agnSendTrapParameter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies if the agent will attach a specific
parameter to a trap.
For ACE2002 the agent will attach or not the openViewSeverity
parameter according to the value of this parameter:
1 - will attach openViewSeverity.
0 - will not attach openViewSeverity."
::= { agnt 27 }
agnSensorsStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the Sensors (Temperature sensors or others)
existence and status.
Each sensor will be represented by 2 bits,
where the first bit (right) will specify the existence:
(0= Not exist, 1=exist),
and the left bit will specify it's status
(0= OK, 1=FAIL), so for each sensor:
00 - sensor does not exist
01 - sensor exists and status is OK
11 - sensor exists and status is not OK
( e.g. temperature exceeds pre-defined threshold)
bits 0-1 are for first sensor
bits 2-3 are for 2nd sensor (if exists)
and so on...
Bit 0 is the LSB."
::= { agnt 28 }
agnStationClockCard OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
notExist (2),
notValid (3),
ok (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the station clock card
existence and status.
notExist - station clock card (piggy) does not exist.
notValid - station clock card exists but clock status is not valid.
ok - station clock card exists, and its status is OK
When the sepcific reason for clock status not being valid is known,
it may be reported by lossOfSync or lossOfSignal values."
::= { agnt 29 }
xcIndexNext OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an appropriate value to
be used for xcIndex when creating
entries in the xcTable. The value
0 indicates that no unassigned entries are
available. To obtain the xcIndex
value for a new entry, the manager issues a
management protocol retrieval operation to obtain
the current value of this object. After each
retrieval, the agent should modify the value to
the next unassigned index.
After a manager retrieves a value the agent will
determine through its local policy when this index
value will be made available for reuse."
::= { agnt 30 }
--XC Table
xcTable OBJECT-TYPE
SYNTAX SEQUENCE OF XcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration of system cross-connect entries.
The table follows the behavior described in RFC 2515,
RFC 1604 regarding the creation deletion and modification
of an entry within the table."
::= { agnt 31 }
xcEntry OBJECT-TYPE
SYNTAX XcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { xcIndex, xcIfIndex1, xcVpi, xcVci, xcIfIndex2 }
::= { xcTable 1}
XcEntry ::=
SEQUENCE {
xcIndex Integer32,
xcIfIndex1 Integer32,
xcVpi Integer32,
xcVci Integer32,
xcIfIndex2 Integer32,
xcRowStatus RowStatus,
xcDescr DisplayString,
xcAdminStatus INTEGER,
xcOperStatus INTEGER,
xcAttachedIfType INTEGER,
xcInputPriority Integer32,
xcBitMapping Integer32
}
xcIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cross Connect Identifier."
::= { xcEntry 1 }
xcIfIndex1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interface Index from the ifTable, which identify one side
of the connection."
::= { xcEntry 2 }
xcVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VPI value."
::= { xcEntry 3 }
xcVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VCI value."
::= { xcEntry 4 }
xcIfIndex2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interface Index from the ifTable, which identifies the other
side of the connection."
::= { xcEntry 5 }
xcRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter allows NMS to create/delete entries of this table."
::= { xcEntry 6 }
xcDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A textual string containing information about the
xc entry."
::= { xcEntry 7 }
xcAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The desired administrative status of this
bi-directional cross-connect."
::= { xcEntry 8 }
xcOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational status of this bi-directional
cross-connect."
::= { xcEntry 9 }
xcAttachedIfType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
free (2),
routerAtm (3),
lis (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates if the specific VCC is
already attached to any interface, and indicates
the type of the interface.
This object's purpose is to ease the checking to
the NMS.
notApplicable - used for entries that are not LAN (as HDLC),
or when the VCC was attached to a bridge, or
when this parameter is irrelevant.
free - the LAN VCC wasn't attached yet to any router
interface.
routerAtm - attached to an ATM router interface.
lis - attached to a LIS interface."
::= { xcEntry 10 }
xcInputPriority OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is the priority, by which the LAN frames will be
internaly sent to the ATM HW. This parameter is applicable if
atmNteMdlInputPriorityMechanism=enabled.
1 - Highest priority. Will be the first to be sent to the ATM HW.
4 - Lowest priority. Will be the last to be sent to the ATM HW."
::= { xcEntry 11 }
xcBitMapping OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object maps this entry to a bit of an octet string.
For ACE2002 this object maps the LAN VCC to the bit of the
VLAN Port Lists. If the value is '0' then it means that
this VCC is not mapped to a port list or it may be an HDSL
entry."
::= { xcEntry 12 }
systemModule OBJECT IDENTIFIER ::= { agnt 32 }
modlParam OBJECT IDENTIFIER ::= { systemModule 1 }
modlParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModlParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table include parameters for system modules."
::= { modlParam 1 }
modlParamEntry OBJECT-TYPE
SYNTAX ModlParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { modlParamIndex }
::= { modlParamTable 1}
ModlParamEntry ::=
SEQUENCE {
modlParamIndex Integer32,
modlParamReset INTEGER,
modlParamSwdlStatus INTEGER,
modlParamLeds OCTET STRING,
modlParamType INTEGER,
modlParamSwVer DisplayString
}
modlParamIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The module index.
The index can be the slot number or any other module index as described
in the specifications of the device.
For Vmux-2100 device, the index will have values of: 1..4 for slots 1..4."
::= { modlParamEntry 1 }
modlParamReset OBJECT-TYPE
SYNTAX INTEGER {
off (2),
on (3),
factory (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset action to be performed on the module.
Set the parameter will be done always to on(3) or factory (4).
After performing the Reset operation, Agent will automatically set the parameter to off(2)."
::= { modlParamEntry 2 }
modlParamSwdlStatus OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
off (2),
inProcess (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates whatever the swdl is in process or not."
::= {modlParamEntry 3}
modlParamLeds OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the LEDs status of the module.
Each led is represented by 4 bits where the first 2 bits (left) specify the status :
(00=NA, 01=OFF, 10=ON, 11=BLINK),
and the next two bits (right) specify the color :
(00=GREEN, 01=RED, 10=YELLOW, 11=GRAY).
The order of the LEDS is from top to bottom, left to right:
For each row starting from the top, the LEDS are returned from left to right."
::= {modlParamEntry 4}
modlParamType OBJECT-TYPE
SYNTAX INTEGER {
unknown (2),
empty (3),
miRicE1 (4),
miRicT1 (5),
miRicE3 (6),
miRicT3 (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Module Type."
::= { modlParamEntry 5 }
modlParamSwVer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Module's Software Version."
::= { modlParamEntry 6 }
agnNearFarConnection OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
disconnected (2),
connected (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter describes the connection between near-end and far-end agents."
::= { agnt 33 }
agnAccess OBJECT IDENTIFIER ::= {agnt 34}
agnTelnetAccess OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3),
managersOnly (4),
enableSecure (5), -- Deprecated; supported by agnSshAccess = enable(3)
managersOnlySecure(6) -- Deprecated; supported by agnSshAccess = managersOnly(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable accessing the device via Telnet.
disable - no one will be allowed to access the device via Telnet.
enable - all users are allowed Telnet Access.
managersOnly - Only manager stations listed in the manager's list are allowed.
enableSecure - same as 'enable' above + only Secure data will be accepted (SSH)
managersOnlySecure - same as 'managersOnly' above + only Secure data will be
accepted (SSH)."
::= { agnAccess 1 }
agnWebAccess OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3),
managersOnly (4),
enableSecure (5),
managersOnlySecure(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable accessing the device via Web.
disable - no one will be allowed to access the device via Web.
enable - all users are allowed Web Access.
managersOnly - Only manager stations listed in the manager's list are allowed.
enableSecure - same as 'enable' above + only Secure data will be accepted (SSL)
managersOnlySecure - same as 'managersOnly' above + only Secure data will be
accepted (SSL)."
::= { agnAccess 2 }
agnRadiusAccess OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable authentication via RADIUS server."
::= { agnAccess 3 }
agnSshAccess OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3),
managersOnly (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable accessing the device via SSH.
disable - no one will be allowed to access the device via SSH.
enable - all users are allowed SSH Access.
managersOnly - Only manager stations listed in the manager's list are allowed."
::= { agnAccess 4 }
systemInterface OBJECT IDENTIFIER ::= { agnt 35 }
SysIfEntityType ::= INTEGER
-- STATUS current
-- DESCRIPTION
-- "This type defines the Entity Type above the created interface.
-- The values existing in IANAifType MIB
-- should be taken from there only.
-- Additional values can be added, starting from 1000 decimal,
-- when necessary."
{
other(1),
ethernetLan(6),
atm(37),
fastEther(62), -- Fast Ethernet (100BaseT)
ipForward(142), -- Router
teLink(200),
bridge(209)
}
-- Interface Configuration Table
ifCreateTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfCreateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Interface Configuration Table.
This table enables to create interfaces of Entities."
::= { systemInterface 1 }
ifCreateEntry OBJECT-TYPE
SYNTAX IfCreateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Interface Configuration table."
INDEX { ifCreateEntityType , ifCreateEntityIdx ,
ifCreateNumber }
::= { ifCreateTable 1 }
IfCreateEntry ::=
SEQUENCE {
ifCreateEntityType SysIfEntityType,
ifCreateEntityIdx Integer32,
ifCreateNumber Integer32,
ifCreateRowStatus RowStatus,
ifCreateType IANAifType,
ifCreateIndex Integer32,
ifCreateConnectedTo Integer32,
ifCreateParams Unsigned32,
ifCreateConnectionPointer RowPointer
}
ifCreateEntityType OBJECT-TYPE
SYNTAX SysIfEntityType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Type of the Entity that exists above the created interface.
For a Logical Port, this value can be: other (1) when there is no fixed entity above it."
::= { ifCreateEntry 1 }
ifCreateEntityIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Index of the Entity that exists above the created interface.
For a Logical Port, this value can be: 9999 - N/A when there is no fixed entity above it."
::= { ifCreateEntry 2 }
ifCreateNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of the Interface that is created."
::= { ifCreateEntry 3 }
ifCreateRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables the user to
create/delete entries in this table."
::= { ifCreateEntry 4 }
ifCreateType OBJECT-TYPE
SYNTAX IANAifType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the Type of the Interface that is created."
::= { ifCreateEntry 5 }
ifCreateIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the ifIndex of the created Interface.
The ifIndex is assigned by the device."
::= { ifCreateEntry 6 }
ifCreateConnectedTo OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the entity connected to the created Interface.
The value of this object can be ifIndex of the connected entity or any other
number that can identify it."
::= { ifCreateEntry 7 }
ifCreateParams OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents one or more parameters of the created Interface.
Each group of bits (one or more bits) represents a specific parameter
and its possible values.
This object's mapping and interpretation will be specified in each
device's specification documents.
The parameter should be used within the create PDU assuming atomic operation."
::= { ifCreateEntry 8 }
ifCreateConnectionPointer OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter represents the entity that is connected
to this Interface.
It can be used instead of ifCreateConnectedTo.
It is an OBJECT IDENTIFIER.
This parameter's SYNTAX allows the following possibilities:
- can be simply used for entity that is not an interface
- is not limited to include up to 32 bits
The value of this parameter is a pointer to an existing row of a table,
where the entity connected to this Interface is defined
(i.e. the pointer uniquely identifies the connected entity).
Examples:
In case of an interface (from 2863.ifTable):
points to 'ifEntry' of corresponding row
= <ifEntry OID>.<ifIndex>
In case of a VPI/VCI (from 2515.atmVclTable):
points to 'atmVclEntry' of corresponding row
= <atmVclEntry OID>.<ATM>.VPI.VCI
In case no entity is connected, value = 0
."
::= { ifCreateEntry 9 }
interfacePerformance OBJECT IDENTIFIER ::= { systemInterface 2 }
ifPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interface Performance Table.
The propose of this table is to support statistics counters having 64 bit
by using 2 parameters with syntax= Integer32.
This is because SNMPv1 does not support Counter64 properly.
For SNMPv3, ifPerfHCCounter (Counter64) may be supported. "
::= { interfacePerformance 1 }
ifPerfEntry OBJECT-TYPE
SYNTAX IfPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Interface Performance Table."
INDEX { ifIndex, ifPerfCounterType }
::= { ifPerfTable 1 }
IfPerfEntry ::=
SEQUENCE {
ifPerfCounterType Integer32,
ifPerfLowCounterPart Unsigned32,
ifPerfHighCounterPart Unsigned32,
ifPerfHCCounter Counter64
}
ifPerfCounterType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"2nd index of the ifPerfTable.
This parameter represents the Counter Type.
Each application can have a different association between this object's
value and counter type - see relevant application spec.
For VPLS-MTU application use the following values:
1= Rx Octets, 2= Tx Octets, 3= Rx Frames, 4= Tx Frames, 5=Rx Dropped Frames,
6= Tx Dropped Frames.
Optionally, counter type description appears in agnListDecodingTable "
::= { ifPerfEntry 1 }
ifPerfLowCounterPart OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"In order to support Counters having 64 bit length,
the performance counter is divided into two 32 bit parameters as follows:
[ 64 bit parameter ] = [ High 32 bit parameter ][ Low 32 bit parameter ].
This parameter holds the Low 32 bits of the counter,
while the following parameter holds the High 32 bits of the counter."
::= { ifPerfEntry 2 }
ifPerfHighCounterPart OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter holds the High 32 bits of the counter
(see description in the above parameter)."
::= { ifPerfEntry 3 }
ifPerfHCCounter OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This High Capacity counter holds whole 64 bits of the counter
indicated by ifPerfCounterType (concatenates both counter parts
ifPerfHighCounterPart&ifPerfLowCounterPart)
This object can be supported only by agents using SNMPv2 or SNMPv3."
::= { ifPerfEntry 4 }
systemOam OBJECT IDENTIFIER ::= { agnt 36 }
systemOamTable OBJECT-TYPE
SYNTAX SEQUENCE OF SystemOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The OAM Configuration Table."
::= { systemOam 1 }
systemOamEntry OBJECT-TYPE
SYNTAX SystemOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the OAM table."
INDEX { systemOamCnfgIdx }
::= { systemOamTable 1 }
SystemOamEntry ::=
SEQUENCE {
systemOamCnfgIdx Integer32,
systemOamFrequency Integer32,
systemOamTimeoutCycles Integer32,
systemOamLinkCheck INTEGER
}
systemOamCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg(1..255) being
accessed ; Idx of 255 relates to the TmpCnfg."
::= { systemOamEntry 1}
systemOamFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time in sec. between 2 OAM packets."
::= { systemOamEntry 2 }
systemOamTimeoutCycles OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"No. of cycles the agent will send OAM packets without receiving a response
from the remote device before declaring that the connection to the remote side
is down - Time Out."
::= { systemOamEntry 3 }
systemOamLinkCheck
OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB object determines whether continuous connectivity Link checks will be
performed by the device for uplinks.
For Vmux-2100: enable (3) value can be set upon device installation.
In this case, TDM Link Connectivity checks can be performed even before the user
configures the Links of the device.If the value is enable (3) and there is
no connection with the remote side, the Test LED will blink on the
Main Board Module."
::= { systemOamEntry 4 }
systemOamDescrTable OBJECT-TYPE
SYNTAX SEQUENCE OF SystemOamDescrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The OAM Descriptors Configuration Table."
::= { systemOam 2 }
systemOamDescrEntry OBJECT-TYPE
SYNTAX SystemOamDescrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the OAM table."
INDEX { systemOamDescrIdx }
::= { systemOamDescrTable 1 }
SystemOamDescrEntry ::=
SEQUENCE {
systemOamDescrIdx Integer32,
systemOamDescrRowStatus RowStatus,
systemOamDescrMode INTEGER,
systemOamDescrCCDirection INTEGER,
systemOamDescrLoopbackOperation INTEGER,
systemOamDescrLoopbackDestAddr OCTET STRING,
systemOamDescrXcCounter Gauge32
}
systemOamDescrIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The OAM Descriptor Index."
::= { systemOamDescrEntry 1 }
systemOamDescrRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enables the user to create/delete entries in this table."
::= { systemOamDescrEntry 2 }
systemOamDescrMode OBJECT-TYPE
SYNTAX INTEGER {
intermediate(1),
segmentTermination(2),
endToEndTermination(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The OAM Mode of the Descriptor."
::= { systemOamDescrEntry 3 }
systemOamDescrCCDirection OBJECT-TYPE
SYNTAX INTEGER {
both (2),
none (3),
source(4),
sink (5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"OAM Continuity Check function mode.
both(2) - Agent sends OAM CC cells and checks received OAM CC cells.
none(3) - Agent does not send and does not check received OAM CC cells.
source(4)- Agent sends OAM CC cells.
sink(5) - Agent checks received OAM CC cells."
::= { systemOamDescrEntry 4 }
systemOamDescrLoopbackOperation OBJECT-TYPE
SYNTAX INTEGER {
off (2),
on (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The OAM Loopback function mode.
off(2) - Stop sending loopback OAM cells.
on(3) - Start loopback OAM cells."
::= { systemOamDescrEntry 5 }
systemOamDescrLoopbackDestAddr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Loopback Destination Address."
::= { systemOamDescrEntry 6 }
systemOamDescrXcCounter OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of connections that use this OAM Descriptor."
::= { systemOamDescrEntry 7 }
agnDeviceView OBJECT-TYPE
SYNTAX INTEGER
{
oldLook (2),
newLook (3),
newLook2 (4),
plastic (5),
metal (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable denotes the view of the device:
Look: old look, new look or new look 2.
Material: Plastic or Metal."
::= { agnt 37 }
bitMappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF BitMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table maps bits of an octet string to an interface.
For ACE-2002 this table is used to map bits of VLAN port lists
to LAN VCC's. This table is the opposite view of the xcTable for
xcBitMapping. It is used to ease the bit translation for the NMS."
::= { agnt 38 }
bitMappingEntry OBJECT-TYPE
SYNTAX BitMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in the table describes a correlation of a bit location to
an interface.
For ACE-2002 - Upon creation of a new LAN VCC the agent will add an
entry to this table that will define the bit location for that VCC."
INDEX { bitMappingLocation }
::= { bitMappingTable 1}
BitMappingEntry ::=
SEQUENCE {
bitMappingLocation Integer32,
bitMappingIndex Integer32
}
bitMappingLocation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The bit location in an octet string."
::= { bitMappingEntry 1 }
bitMappingIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface index or any other index that should be mapped."
::= { bitMappingEntry 2 }
bitMappingView OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A view of the bitMappingTable in one object - each entry in the
biMappingTable will have the corresponding Bit of this object
(bitMappingLocation) = '1'.
For ACE-2002 it is used to describe all the existing LAN VCC's
So that the NMS can easily calculate which VCC's can be selected
as members for a VLAN, instead of reading all the bitMapping Table."
::= { agnt 39 }
hostTable OBJECT-TYPE
SYNTAX SEQUENCE OF HostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Host interface table."
::= { agnt 40 }
hostEntry OBJECT-TYPE
SYNTAX HostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Host Table.
The hostParam1, hostParam2, and hostParam3 entries may
have different use in different applications."
INDEX { hostIndex }
::= { hostTable 1 }
HostEntry ::=
SEQUENCE {
hostIndex Integer32,
hostIP IpAddress,
hostIPMask IpAddress,
hostDefaultNextHop IpAddress,
hostMode Integer32,
hostParam1 Integer32,
hostParam2 Integer32,
hostParam3 Integer32,
hostRowStatus RowStatus,
hostVlanTagging INTEGER,
hostVlanId Integer32,
hostVlanPriority Integer32
}
hostIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Host Table Index. This index can have the same value as Host No."
::= { hostEntry 1 }
hostIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The host interface IP address."
::= { hostEntry 2 }
hostIPMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The host interface subnet mask."
::= { hostEntry 3 }
hostDefaultNextHop OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The host interface Default Next Hop address."
::= { hostEntry 4 }
hostMode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter represents the Host mode of operation.
There can be different values for each application.
For example:
Not Applicable = 1."
::= { hostEntry 5 }
hostParam1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter represents the first Host parameter.
There can be different values for each application.
For example:
Not Applicable = 1."
::= { hostEntry 6 }
hostParam2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter represents the 2nd Host parameter.
There can be different values for each application."
::= { hostEntry 7 }
hostParam3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter represents the 3nd Host parameter.
There can be different values for each application."
::= { hostEntry 8 }
hostRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= { hostEntry 9 }
hostVlanTagging OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
untag (2),
tag (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Host VLAN support (Tagging).
untag - No support of VLAN Tagging.
tag - 4 VLAN bytes will be added to the frame."
::= { hostEntry 10 }
hostVlanId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Host VLAN ID."
::= { hostEntry 11 }
hostVlanPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Host VLAN Frame priority."
::= { hostEntry 12 }
invNameXCTable OBJECT-TYPE
SYNTAX SEQUENCE OF InvNameXCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Inverse Name XC Table.
This table can be used to ease the search for a connection first index
by the connection name."
::= { agnt 41 }
invNameXCEntry OBJECT-TYPE
SYNTAX InvNameXCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
INDEX { IMPLIED invNameXC }
::= { invNameXCTable 1 }
InvNameXCEntry ::= SEQUENCE {
invNameXC SnmpAdminString,
invNameXCType OBJECT IDENTIFIER,
invNameXCIndex Integer32
}
invNameXC OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (1..64))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The unique Connection name,
associated to a Cross-Connection."
::= { invNameXCEntry 1 }
invNameXCType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OBJECT IDENTIFIER of the respective XC Table.
Examples:
XC Table invNameXCType
---------------------------------------------------
atmVpCrossConnectTable 1.3.6.1.2.1.37.1.9
atmVcCrossConnectTable 1.3.6.1.2.1.37.1.11
atmfCESConfTable 1.3.6.1.4.1.353.5.2.2.1.1
."
::= { invNameXCEntry 2 }
invNameXCIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The XC Table (invNameXCType) may include more than one index.
This object represents the value of the first XC Index."
::= { invNameXCEntry 3 }
agnDeviceCapabilities OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the optional capabilities that are implemented by this device
and are manageable through this MIB.
For each capability 1 BIT is allocated in each Octet starting from the LSB.
If the value of the BIT = 1, the capability is Enabled.
If the value of the BIT = 0, the capability is Disabled.
For bit assignment, refer to device specification.
Capabilities example:
Router - BIT 0 (0000 0001 = 01 Hex = 1 Decimal).
The 2nd octet (MSB) will represent the maximum number of intervals that
the Agent can keep in its DB (same for all ports).
For Vmux, this object describes agent's support of LBRAD coder feature:
1 octet ; bit 0 (LSB).
'1' - LBRAD feature is supported
'0' - LBRAD feature is not supported."
::= {agnt 42}
rowInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF RowInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table holds information of other tables."
::= { agnt 43 }
rowInfoEntry OBJECT-TYPE
SYNTAX RowInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
INDEX { rowInfoTableId }
::= { rowInfoTable 1 }
RowInfoEntry ::= SEQUENCE {
rowInfoTableId OBJECT IDENTIFIER,
rowInfoCounter Integer32,
rowInfoIndexNext Integer32,
rowInfoMaxNoOfRows Integer32
}
rowInfoTableId OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The OBJECT IDENTIFIER of the Table,
which its information is held by this table (rowInfoTable).
Examples:
Table Name rowInfoTableId
---------------------------------------------------
atmTrafficDescrParamTable 1.3.6.1.2.1.37.1.5
atmVpCrossConnectTable 1.3.6.1.2.1.37.1.9
atmVcCrossConnectTable 1.3.6.1.2.1.37.1.11
atmfCESConfTable 1.3.6.1.4.1.353.5.2.2.1.1
."
::= { rowInfoEntry 1 }
rowInfoCounter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Number of rows in the table, indicated by rowInfoTableId."
::= { rowInfoEntry 2 }
rowInfoIndexNext OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The First Free Index of the table, indicated by rowInfoTableId."
::= { rowInfoEntry 3 }
rowInfoMaxNoOfRows OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum possible number of rows in the table, indicated by rowInfoTableId."
::= { rowInfoEntry 4 }
agnStoreCmd OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
inFlash (3),
asDefConfigFile (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Store command.
inFlash(3) = store the current Agent configuration in Flash memory.
asDefConfigFile(4) = store the current Agent configuration as
Default Configuration file (e.g. 'DefConfig.cfg').
Agent will perform the required command and change automatically
the value of this object to off(2)."
::= { agnt 44 }
agnFunctionTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnFunctionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used in order to activate/deactivate device functions.
The index indicates the function. Each function can be Enabled or Disabled."
::= { agnt 45 }
agnFunctionEntry OBJECT-TYPE
SYNTAX AgnFunctionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
INDEX { agnFunction }
::= { agnFunctionTable 1 }
AgnFunctionEntry ::= SEQUENCE {
agnFunction INTEGER,
agnFunctionActivation INTEGER
}
agnFunction OBJECT-TYPE
SYNTAX INTEGER
{
routing (2),
backup (3),
alarmForwarding (4),
uplinkLoopDetect (5),
systemClock (6),
nps (7)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This MIB object indicates the function that will be enabled or disabled
in the device.
alarmForwarding= Fault Propagation (usually towards user port).
For Vmux:
routing (2) - enable/disable Router
backup (3) - enable/disable Backup between E1/T1/Serial Link and ETH.
uplinkLoopDetect (5) - enable/disable Loop Detection on the TDM Uplink.
systemClock (6) - enable/disable the System Clock.
nps (7) - N+1 Protection Switching device physically connected to I/O
modules in Gmux2000.
"
::= { agnFunctionEntry 1 }
agnFunctionActivation OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB object indicates the activation of the current function."
::= { agnFunctionEntry 2 }
agnManagerConfigPorts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable defines from which port/s this manager can manage the device.
The value is a sum of 2**n, where n is a bit assigned to a certain port.
For RIC-E1 and ETX 102 the value will be according to the ports
combination:
Network = bit 0
User= bit 1
For Example: All = 3."
::= {agnt 46 }
agnEgressRateRange OBJECT-TYPE
SYNTAX INTEGER
{
unlimited (1),
range1 (2),
range2 (3),
range3 (4),
range4 (5),
range5 (6),
range6 (7),
range7 (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable defines the valid ranges of egress rate.
For example, for ETX 102:
range 1 (2)= 128KBPS - 8MBPS,
range 2 (3)= 256KBPS - 16MBPS,
range 3 (4)= 512KBPS - 32MBPS,
range 4 (5)= 1MBPS - 64MBPS,
range 5 (6)= 1.5MBPS - 80MBPS."
::= {agnt 47 }
agnNoOfCurrentConns OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the number of connections
currently configured for the agent."
::= { agnt 48 }
agnIngressRateRange OBJECT-TYPE
SYNTAX INTEGER
{
unlimited (1),
range1 (2),
range2 (3),
range3 (4),
range4 (5),
range5 (6),
range6 (7),
range7 (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable defines the valid ranges of ingress rate.
For example, for ETX 102:
range 1 (2)= 128KBPS - 8MBPS,
range 2 (3)= 256KBPS - 16MBPS,
range 3 (4)= 512KBPS - 32MBPS,
range 4 (5)= 1MBPS - 64MBPS,
range 5 (6)= 1.5MBPS - 80MBPS."
::= {agnt 49 }
alarmForwardingTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmForwardingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Alarm Forwarding Mechanism will be operated
for this table entries."
::= { agnt 50 }
alarmForwardingEntry OBJECT-TYPE
SYNTAX AlarmForwardingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in this table is a pair of ports that
the Alarm Forwarding Mechanism is determined for."
INDEX { alarmForwardingFailPort, alarmForwardingToPort }
::= { alarmForwardingTable 1 }
AlarmForwardingEntry ::=
SEQUENCE {
alarmForwardingFailPort
Integer32,
alarmForwardingToPort
Integer32,
alarmForwardingRowStatus
RowStatus,
alarmForwardingRecoveryTime
Integer32,
alarmForwardingGroupConditions
Integer32,
alarmForwardingCause
BITS,
alarmForwardingRecoveryMode
INTEGER,
alarmForwardingRecoveryCommand
INTEGER,
alarmForwardingDelay
Unsigned32,
alarmForwardingDirection
INTEGER,
alarmForwardingAction
BITS
}
alarmForwardingFailPort OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Index of the port on which a fail occurs."
::= { alarmForwardingEntry 1}
alarmForwardingToPort OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Index of the port that will be affected
upon the failure of the alarmForwardingFailPort."
::= { alarmForwardingEntry 2}
alarmForwardingRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/ Deletion of rows in the table."
::= { alarmForwardingEntry 3}
alarmForwardingRecoveryTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter defines the maximum time (sec)
the affected port will hold the down state."
::= { alarmForwardingEntry 4 }
alarmForwardingGroupConditions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter is applicable when there is a group of interfaces
in which a fault may occur, and one interface to which alarm is propagated (forwarded).
0 = All - Forwarding will take place only when all interfaces of the
same group are faulty.
1 = Single - Forwarding will take place when at least one (single)
interface of the same group (any of them) is faulty.
n - forwarding will take place only when n (n < all)
interfaces of the same group fail."
::= { alarmForwardingEntry 5 }
alarmForwardingCause OBJECT-TYPE
SYNTAX BITS
{
loss (0),
ais (1),
rdi (2),
protocolDown (3),
oamSignalingEfm (4),
oamSignalingCfm (5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Bit map representing the cause upon which alarm forwarding will take place.
bit 0 - LOSS (LINE DOWN)
bit 1 - AIS
bit 2 - RDI
bit 3 - PROTOCOL DOWN.
bit 4 - OAM Signaling - EFM
bit 5 - OAM Signaling - CFM. "
::= { alarmForwardingEntry 6 }
alarmForwardingRecoveryMode OBJECT-TYPE
SYNTAX INTEGER
{
manual (1),
automatic (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter determines the Recovery Mode.
manual - The user should stop the alarm forwarding
by using the alarmForwardingRecoveryCommand.
automatic - Alarm forwarding will be automatically
stopped upon alarmForwardingFailPort recovery."
::= { alarmForwardingEntry 7 }
alarmForwardingRecoveryCommand OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter is a command. It is applicable when
alarmForwardingRecoveryMode = manual.
on - Will stop alarm forwarding.
After setting to 'On', the agent will set this parameter back to 'Off'."
::= { alarmForwardingEntry 8 }
alarmForwardingDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter determines the period of time (in seconds) the
alarm of the alarmForwardingFailPort should exist before
starting alarm forwarding."
::= { alarmForwardingEntry 9 }
alarmForwardingDirection OBJECT-TYPE
SYNTAX INTEGER
{
unidirectional (1),
bidirectional (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter determines the Direction of the Alarm Forwarding.
unidirectional - alarmForwardingFailPort affects the
alarmForwardingToPort.
bidirectional - alarmForwardingFailPort affects the
alarmForwardingToPort AND vice-versa.
For such cases, this value will be selected, instead of
entering an additional unidirectional entry
in the table, where the indexes are swapped."
::= { alarmForwardingEntry 10 }
alarmForwardingAction OBJECT-TYPE
SYNTAX BITS
{
noAction (0),
interfaceDeactivation (1),
oamSignaling (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Bit map representing the action to be performed when alarm forwarding will take place.
bit 0 - No Action.
'1' value - device should NOT perform any action, though other bits
indicate the action to be taken.
'0' value - device should perform the action/s indicated by rest of
the bits. In this case, one of the other bits should be '1'.
bit 1 - Interface Deactivation (of the affected Port: alarmForwardingToPort)
bit 2 - OAM Signaling. Affected Port (alarmForwardingToPort) will send
special OAM Signaling to the Far-End unit about the Failure.
This object will be used only for devices that support Deactivation per entry OR
can support more than one action."
::= { alarmForwardingEntry 11 }
agnSwVersionSwapCmd OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
mainAndBackup (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SW switch command.
mainAndBackup (3) = Swap between Main SW and the backup one.
Agent will perform the required command and change automatically
the value of this object to off(2)."
::= { agnt 51 }
agnClockSource OBJECT IDENTIFIER ::= {agnt 52}
agnClkSrcPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnClkSrcPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Pool of Ports for the Master/Fallback Clock Source
and of Recovered IDs.
For devices with more than one configuration:
Set operation is valid only to the TmpCnfg entry."
::= { agnClockSource 1}
agnClkSrcPortEntry OBJECT-TYPE
SYNTAX AgnClkSrcPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table."
INDEX {agnClkSrcPortCnfgIdx, agnClkSrcPortSrcIdx, agnClkSrcPortIdx}
::= { agnClkSrcPortTable 1}
AgnClkSrcPortEntry ::=
SEQUENCE {
agnClkSrcPortCnfgIdx Integer32,
agnClkSrcPortSrcIdx INTEGER,
agnClkSrcPortIdx Integer32,
agnClkSrcPort Integer32,
agnClkSrcPortRowStatus RowStatus,
agnClkSrcPortAdminStatus INTEGER,
agnClkSrcPortType INTEGER,
agnClkSrcPortQuality INTEGER,
agnClkSrcPortNetType INTEGER,
agnClkSrcPortState INTEGER,
agnClkSrcPortSrcType INTEGER
}
agnClkSrcPortCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg being
accessed ; Idx of 255 relates to the TmpCnfg.
For product supporting a single configuration, the value will be 1."
::= { agnClkSrcPortEntry 1}
agnClkSrcPortSrcIdx OBJECT-TYPE
SYNTAX INTEGER
{
master (1),
fallback (2),
recovered (3)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Clock Source Index.
master - refers to Master clock
fallback - refers to Fallback clock
recovered - refers to Recovered clock."
::= { agnClkSrcPortEntry 2}
agnClkSrcPortIdx OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the running Idx of the Port/Recovered ID that is
to be used as Clock Source, for each agnClkSrcPortSrcIdx instance."
::= { agnClkSrcPortEntry 3}
agnClkSrcPort OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the Port/Interface/Recovered ID # that is
to be used as Clock Source.
In case of agnClkSrcPortSrcIdx=recovered (3) - it indicates the PW number.
When agnClkSrcPortSrcIdx=master(1) or fallback(2), this list may include
both External Ports and Recovered IDs (mixed). Therefore, in order to know
which type of instance is indicated, agnClkSrcPortSrcType will be used:
- When agnClkSrcPortSrcType=rxClock(3), this object indicates a Port index.
- When agnClkSrcPortSrcType=recovered(12), this object indicates a Recovered ID."
::= { agnClkSrcPortEntry 4}
agnClkSrcPortRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables Creation/ Deletion of rows in the table."
::= { agnClkSrcPortEntry 5}
agnClkSrcPortAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
down (2),
up (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the Recovered Clock Administrative Status."
::= { agnClkSrcPortEntry 6 }
agnClkSrcPortType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
adaptive (2),
ieee1588v2 (3),
commonClock (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is relevant only in case of Recovery Clock.
It indicates the Clock Type."
::= { agnClkSrcPortEntry 7 }
agnClkSrcPortQuality OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
stratum1 (2),
stratum2 (3),
stratum3 (4),
stratum3e (5),
stratum4 (6)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the Clock Source Quality."
::= { agnClkSrcPortEntry 8 }
agnClkSrcPortNetType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
typeA (2),
typeB (3),
typeC (4),
typeD (5),
typeE (6),
typeF (7)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is relevant only in case of Recovery Clock.
It indicates the Clock Network Type, i.e.
the PSN network characteristics and behavior."
::= { agnClkSrcPortEntry 9 }
agnClkSrcPortState OBJECT-TYPE
SYNTAX INTEGER
{
freeRun (1),
frequencyAcquisition (2),
rapidPhaseLock (3),
finePhaseLock (4),
holdover (5),
notApplicable (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Clock State.
freeRun(1) -
Clock recovery is not locked to any clock.
frequencyAcquisition(2) -
Adaptive clock recovery is learning the frequency.
rapidPhaseLock(3) -
Clock recovery is in training process till it reaches fine phase lock.
finePhaseLock(4) -
Clock is locked and clock recovery is qualified and stable.
holdover(5) -
Clock recovery is in holdover mode.
notApplicable(6) -
Clock recovery is not applicable."
::= { agnClkSrcPortEntry 10 }
agnClkSrcPortSrcType OBJECT-TYPE
SYNTAX INTEGER
{
rxClock (3),
recovered(12)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the Src Type of each entry in the list of source
instances, when agnClkSrcPortSrcIdx=master(1)or fallback(2).
According to this type, agnClkSrcPort gets the relevant meaning (Port index
or Recovered ID)."
::= { agnClkSrcPortEntry 11 }
agnCurrClkTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCurrClkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Current Clock Source."
::= { agnClockSource 2}
agnCurrClkEntry OBJECT-TYPE
SYNTAX AgnCurrClkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table."
INDEX {agnCurrClkObjIdx}
::= { agnCurrClkTable 1}
AgnCurrClkEntry ::=
SEQUENCE {
agnCurrClkObjIdx Integer32,
agnCurrClkMode INTEGER,
agnCurrClkSrc INTEGER,
agnCurrClkPort Integer32,
agnCurrClkHoldover INTEGER,
agnCurrClkSsmBased INTEGER,
agnCurrClkState INTEGER,
agnCurrClkQualification INTEGER
}
agnCurrClkObjIdx OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This MIB object identifies the object for which the Clock Source
is used (System, Other System, Card)."
::= { agnCurrClkEntry 1}
agnCurrClkMode OBJECT-TYPE
SYNTAX INTEGER
{
master (1),
fallback (2),
internal (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Clock Source Mode.
master - refers Master clock
fallback - refers Fallback clock
internal - only when both Master and Fallback Sources failed "
::= { agnCurrClkEntry 2}
agnCurrClkSrc OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
internal (2),
rxClk (3),
station (4), -- station A (for GMUX2000)
lbt (5),
ntr (6),
adaptive (7),
stationB (8),
automatic (9),
system (10),
sSubsystem (11),
recovered (12),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Current Clock Source."
::= { agnCurrClkEntry 3}
agnCurrClkPort OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Port/Interface/Recovered ID that is
Currently used as Clock Source.
- When agnCurrClkSrc=rxClock(3), this object indicates a Port index.
- When agnCurrClkSrc=recovered(12), this object indicates a Recovered ID."
::= { agnCurrClkEntry 4}
agnCurrClkHoldover OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
no (2),
yes (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Clock Holdover State.
As a last resort, in the absence of higher quality timing:
- a SONET/SDH object can enter 'holdover' state, until higher quality
external timing becomes available again. In this state (value=yes)
the SONET/SDH object uses its own timing circuits for clock of the
SONET/SDH signal.
- for other objects, the 'holdover'=yes state means that the object uses
last available clock (stored by the object) for a pre-defined time,
until another clock source is used."
::= { agnCurrClkEntry 5}
agnCurrClkSsmBased OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates whether clock source
is selected based on receive clock quality.
Clock quality is indicated in S1 byte inside SONET/SDH overhead,
(encoded as SSM - Synchronization Status Messaging)."
::= { agnCurrClkEntry 6}
agnCurrClkState OBJECT-TYPE
SYNTAX INTEGER
{
freeRun (1),
rapidPhaseLock (2),
finePhaseLock (3),
holdover (4),
frequencyAcquisition (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Current Clock State.
freeRun(1) -
Current clock state machine is not locked
and run from the internal oscillator.
rapidPhaseLock(2) -
Current clock state machine is locked.
finePhaseLock(3) -
Current clock state machine is in pre-locking.
holdover(4) -
Current clock state machine is in holdover mode
(due to loss of event).
frequencyAcquisition(5) -
Adaptive clock recovery is learning the frequency."
::= { agnCurrClkEntry 7 }
agnCurrClkQualification OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disqualified (2),
qualified (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Current Clock Qualification
and defines whether the PLL can locked according to the stratum definitions."
::= { agnCurrClkEntry 8 }
agnClockMonitoring OBJECT IDENTIFIER ::= { agnClockSource 3 }
agnClkCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnClkCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Clock Current table."
::= { agnClockMonitoring 1 }
agnClkCurrentEntry OBJECT-TYPE
SYNTAX AgnClkCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Clock Current table."
INDEX { agnClkCurrentIndex }
::= { agnClkCurrentTable 1 }
AgnClkCurrentEntry ::=
SEQUENCE {
agnClkCurrentIndex Unsigned32,
agnClkCurrentRxPackets Gauge32,
agnClkCurrentLostPackets Gauge32,
agnClkCurrentOutOfOrderPackets Gauge32,
agnClkCurrentBufferUnderflow Gauge32
}
agnClkCurrentIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Index that is uniquely represents the Clock."
::= { agnClkCurrentEntry 1 }
agnClkCurrentRxPackets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Received Packets,
encountered by a Bridge Port in the current 15 minute interval."
::= { agnClkCurrentEntry 2 }
agnClkCurrentLostPackets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Lost Packets,
encountered by a Bridge Port in the current 15 minute interval."
::= { agnClkCurrentEntry 3 }
agnClkCurrentOutOfOrderPackets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of times Out-of-Order Packets
encountered by a Bridge Port in the current 15 minute interval."
::= { agnClkCurrentEntry 4 }
agnClkCurrentBufferUnderflow OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of times Underflow event
encountered by a Bridge Port in the current 15 minute interval."
::= { agnClkCurrentEntry 5 }
agnClkIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnClkIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Clock Interval table."
::= { agnClockMonitoring 2 }
agnClkIntervalEntry OBJECT-TYPE
SYNTAX AgnClkIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Clock Interval table."
INDEX { agnClkIntervalIndex, agnClkIntervalNumber }
::= { agnClkIntervalTable 1 }
AgnClkIntervalEntry ::=
SEQUENCE {
agnClkIntervalIndex Unsigned32,
agnClkIntervalNumber Unsigned32,
agnClkIntervalRxPackets Gauge32,
agnClkIntervalLostPackets Gauge32,
agnClkIntervalOutOfOrderPackets Gauge32,
agnClkIntervalBufferUnderflow Gauge32
}
agnClkIntervalIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Index that is uniquely represents the Clock."
::= { agnClkIntervalEntry 1 }
agnClkIntervalNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96,
where 1 is the most recently completed 15 minute interval
and 96 is the least recently completed 15 minutes interval
(assuming that all 96 intervals exist)."
::= { agnClkIntervalEntry 2 }
agnClkIntervalRxPackets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Received Packets,
encountered by a Bridge Port in one of the previous 96,
individual 15 minute, intervals."
::= { agnClkIntervalEntry 3 }
agnClkIntervalLostPackets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Lost Packets,
encountered by a Bridge Port in one of the previous 96,
individual 15 minute, intervals."
::= { agnClkIntervalEntry 4 }
agnClkIntervalOutOfOrderPackets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of times Out-of-Order Packets
are detected, encountered by a Bridge Port in one of the previous 96,
individual 15 minute, intervals."
::= { agnClkIntervalEntry 5 }
agnClkIntervalBufferUnderflow OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of times Underflow event
is detected, encountered by a Bridge Port in one of the previous 96,
individual 15 minute, intervals."
::= { agnClkIntervalEntry 6 }
agnMaxNoOfConns OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the maximum number of connections
that can be configured for the agent."
::= { agnt 53 }
lag OBJECT IDENTIFIER ::= { agnt 54 }
lagTable OBJECT-TYPE
SYNTAX SEQUENCE OF LagEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table defining Link Aggregation Groups port association,
and other parameters."
::= {lag 1}
lagEntry OBJECT-TYPE
SYNTAX LagEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the LAG table."
INDEX { lagCnfgIdx, lagIdx }
::= { lagTable 1 }
LagEntry ::=
SEQUENCE {
lagCnfgIdx Unsigned32,
lagIdx Unsigned32,
lagPortMembers PortList,
lagDistributionMethod INTEGER,
lagRecoveryMode INTEGER,
lagWaitToRestore Unsigned32,
lagRowStatus RowStatus,
lagShutDownDurationUponFlip Unsigned32,
lagRdnMethod INTEGER,
lagLacpEnable INTEGER
}
lagCnfgIdx OBJECT-TYPE
SYNTAX Unsigned32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg(1..255) being
accessed ; Idx of 255 relates to the TmpCnfg."
::= { lagEntry 1}
lagIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates LAG unique index."
::= { lagEntry 2}
lagPortMembers OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The set of ports which are permanently assigned to the
Link Aggregation Group.
The default value of this object is a string of zeros."
::= { lagEntry 3}
lagDistributionMethod OBJECT-TYPE
SYNTAX INTEGER
{
portBased (2),
oneToOne (3),
sourceMac (4),
destinationMac (5),
sourceXorDestinationMac (6),
sourceAndDestinationMac (7),
sourceIp (8),
destinationIp (9),
sourceAndDestinationMacAndIp (10),
roundRobin (11)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object defines the criteria for the 802.3ad (LAG)
to split the traffic between ports"
::= { lagEntry 4}
lagRecoveryMode OBJECT-TYPE
SYNTAX INTEGER
{
nonRevertive (2),
revertive (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object defines whether traffic will be returned to
a port after its recovery.
This object is applicable only when
lagDistributionMethod= oneToOne (3)."
::= { lagEntry 5}
lagWaitToRestore OBJECT-TYPE
SYNTAX Unsigned32 (0..720)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object defines traffic recovery time (in seconds)
to the port after its recovery.
This object is applicable only when
lagRecoveryMode= revertive (3)."
::= { lagEntry 6}
lagRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables user to create/delete
entries of this table.
Note:
When using LAG standard package, this table is static,
hence, only the values active(1), notInService(2) are used."
::= { lagEntry 7}
lagShutDownDurationUponFlip OBJECT-TYPE
SYNTAX Unsigned32 (0..30)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object defines the duration (in seconds) the active
port transmission is shut down after LAG Flip occurs.
The transmission is shut down and then opened again (after the duration
defined by this object), in order to cause the other side to flip
to the new active port.
0=no shut-down.
This object is applicable only when lagDistributionMethod=oneToOne(3)
and mainly when each of the Links of our device is connected to a different device."
::= { lagEntry 8}
lagRdnMethod OBJECT-TYPE
SYNTAX INTEGER
{
loadSharing (1),
redundancy (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object defines the redundancy method."
::= { lagEntry 9}
lagLacpEnable OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enabling/Disabling the LACP for a LAG.
The LACP will be enabled for all ports belonging to this LAG."
::= { lagEntry 10}
lagStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF LagStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table defining Link Aggregation Groups Redundancy. This table is applicable only
when lagDistributionMethod = oneToOne."
::= {lag 2}
lagStatEntry OBJECT-TYPE
SYNTAX LagStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the LAG Status table."
INDEX { lagIdx }
::= { lagStatTable 1 }
LagStatEntry ::=
SEQUENCE {
lagStatForcePort Unsigned32,
lagStatActivePort Unsigned32
}
lagStatForcePort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables user to enforce the active port.
0 = No Enforcement; Otherwise the ifIndex of the port."
::= { lagStatEntry 1}
lagStatActivePort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the current active port. It is applicable only
when lagDistributionMethod = oneToOne. The value is the ifIndex of the port.
0 = none of the ports is active."
::= { lagStatEntry 2}
gfp OBJECT IDENTIFIER ::= { agnt 55 }
gfpCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF GfpCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration table for GFP (General Framing Protocol)."
::= {gfp 1}
gfpCnfgEntry OBJECT-TYPE
SYNTAX GfpCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the GFP configuration table."
INDEX { ifIndex, gfpCnfgIdx }
::= { gfpCnfgTable 1 }
GfpCnfgEntry ::=
SEQUENCE {
gfpCnfgIdx Unsigned32,
gfpPayloadFcs INTEGER,
gfpRxTxScramble INTEGER,
gfpVcatHeader INTEGER
}
gfpCnfgIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index to GFP configuration table."
::= { gfpCnfgEntry 1 }
gfpPayloadFcs OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines whether protocol header will
include FCS."
::= { gfpCnfgEntry 2 }
gfpRxTxScramble OBJECT-TYPE
SYNTAX INTEGER
{
noScramble (1),
rxTxScramble (2),
rxOnlyScramble (3),
txOnlyScramble (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines whether transmission will be scrambled."
::= { gfpCnfgEntry 3 }
gfpVcatHeader OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VCAT header is LCAS CONTROL packet as described in the G-7043.
one control packet is transmitted in a period of 16 Multi frame"
::= { gfpCnfgEntry 4}
--Group Table
agnGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that enables associating components to Group/s
(or removing components of a group).
The Group Idx can then be used in other tables (e.g alarmForwardingTable)."
::= {agnt 56}
agnGroupEntry OBJECT-TYPE
SYNTAX AgnGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the agnGroupTable."
INDEX { agnGroupCnfgIdx, agnGroupIdx, agnGroupComponentIdx }
::= { agnGroupTable 1 }
AgnGroupEntry ::=
SEQUENCE {
agnGroupCnfgIdx Unsigned32,
agnGroupIdx Unsigned32,
agnGroupComponentIdx Unsigned32,
agnGroupRowStatus RowStatus
}
agnGroupCnfgIdx OBJECT-TYPE
SYNTAX Unsigned32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg(1..255) being
accessed ; Idx of 255 relates to the TmpCnfg."
::= { agnGroupEntry 1}
agnGroupIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates a unique Group Index."
::= { agnGroupEntry 2}
agnGroupComponentIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates a unique Component Index that belongs to the
Group defined by agnGroupIdx."
::= { agnGroupEntry 3}
agnGroupRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables user to create/delete entries of this table.
destroy - If a Group is used in another table, Agent may not allow
destroying the entry/ies that belong to this Group Index."
::= { agnGroupEntry 4}
agnStatNoOfUploadedIntervals OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates the Number of Intervals that were
successfully collected and uploaded in the last statistics collection session."
::= { agnt 57 }
agnSyslog OBJECT IDENTIFIER ::= { agnt 58 }
agnSyslogDeviceUdpPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP Port of the device, from which Syslog messages are sent.
Default=514."
::= { agnSyslog 1 }
agnSyslogFacility OBJECT-TYPE
SYNTAX INTEGER
{
-- (0)..(15) are reserved for Standard values + (16) is reserved for Local 0.
local1 (17),
local2 (18),
local3 (19),
local4 (20),
local5 (21),
local6 (22),
local7 (23)
-- (99) is reserved for 'noMap' - indicating that the appropriate facility
-- will be provided by the application
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A user defined SW module, task or function, from which Syslog messages are sent
to the remote Server."
::= { agnSyslog 2 }
agnSyslogSeverityLevel OBJECT-TYPE
SYNTAX INTEGER
{
critical (1), -- action must be taken immediately (in standard: 'alert')
major (2), -- critical conditions (in standard: 'critical')
minor (3), -- error conditions (in standard: 'error')
warning (4), -- warning condition (in standard: 'warning')
event (5), -- normal but significant condition (in standard: 'notice')
info (6), -- informational messages (in standard: 'informational')
debug (7) -- debug-level messages (in standard: 'debug')
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Device will send events equal or exceeding this severity level (configured by user)."
::= { agnSyslog 3 }
agnNetworkInterfaceType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
t1 (2),
t3 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB object indicates the network interface type to be used
by the device.
It is used for devices that use only one network port type."
::= { agnt 59 }
agnTrapDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable enables the user to set a delay (in seconds) before a trap is sent.
This delay will be used only for traps that need to be sent during device initialization.
It is needed because the device connected to our device starts transmitting traps later.
The delay starts from the end of the Boot process. The device will keep the init traps
in the correct order, and cancel those which clear former ones in the list.
After this init delay, traps will be sent without a delay."
::= { agnt 60 }
trapManagement OBJECT IDENTIFIER ::= { agnt 61 }
trapMngVars OBJECT IDENTIFIER ::= { trapManagement 1 }
trapState OBJECT-TYPE
SYNTAX INTEGER
{
start (2),
end (3)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"State of current trap (sent within a trap)."
::= { trapMngVars 1 }
trapSeqId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Sequence ID of current trap (sent within a trap)."
::= { trapMngVars 2 }
alarmSync OBJECT IDENTIFIER ::= { trapManagement 2 }
alarmSyncEvents OBJECT IDENTIFIER ::= { alarmSync 0 }
hardSyncTrap NOTIFICATION-TYPE
OBJECTS { trapState }
STATUS current
DESCRIPTION
"This trap is sent whenever Hard Synchronization process starts or ends
(Hard Synchronization retrieves current status of Agent)."
::= { alarmSyncEvents 1 }
alarmSyncTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmSyncEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes Alarm Synchronization information
for each Logical Group of managers."
::= { alarmSync 1 }
alarmSyncEntry OBJECT-TYPE
SYNTAX AlarmSyncEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
INDEX { alarmSyncGroupId }
::= { alarmSyncTable 1 }
AlarmSyncEntry ::= SEQUENCE {
alarmSyncGroupId Unsigned32,
alarmSyncLastSentSeqId Counter32,
alarmSyncCmd INTEGER,
alarmSyncStartSeqId Unsigned32,
alarmSyncEndSeqId Unsigned32
}
alarmSyncGroupId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique Logical Group ID,
which represents a group of managers."
::= { alarmSyncEntry 1 }
alarmSyncLastSentSeqId OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last Sequence ID of trap that is sent
to this Logical Group of managers."
::= { alarmSyncEntry 2 }
alarmSyncCmd OBJECT-TYPE
SYNTAX INTEGER
{
off (1),
softSync (2),
hardSync (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Initates an Alarm Synchronization request
for this Logical Group of managers.
softSync(2) - sends Soft Synchronization request,
in order to synchronize missing traps from Agent.
hardSync(3) - sends Hard Synchronization request,
in order to synchronize current alarms of Agent.
After an Alarm Synchronization process is completed,
Agent will automatically change this value to off(2).
"
::= { alarmSyncEntry 3 }
alarmSyncStartSeqId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"First Sequence ID of Soft Synchronization request
for this Logical Group of managers.
Soft Synchronization request is sent for a range of Sequence IDs.
This object represents the first Sequence ID of this range."
::= { alarmSyncEntry 4 }
alarmSyncEndSeqId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Last Sequence ID of Soft Synchronization request
for this Logical Group of managers.
Soft Synchronization request is sent for a range of Sequence IDs.
This object represents the last Sequence ID of this range."
::= { alarmSyncEntry 5 }
agnStringToIndexTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnStringToIndexEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table holds the conversions of tables from unique String
to numeric index."
::= {agnt 62}
agnStringToIndexEntry OBJECT-TYPE
SYNTAX AgnStringToIndexEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
INDEX { agnStringToIndexTableId,IMPLIED agnStringToIndexUserName }
::= { agnStringToIndexTable 1 }
AgnStringToIndexEntry ::= SEQUENCE {
agnStringToIndexTableId OBJECT IDENTIFIER,
agnStringToIndexUserName SnmpAdminString,
agnStringToIndexTableIndex Unsigned32
}
agnStringToIndexTableId OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The OBJECT IDENTIFIER of the Table, having as index numeric values.
In this table, the value of agnStringToIndexUserName is an attribute."
::= { agnStringToIndexEntry 1 }
agnStringToIndexUserName OBJECT-TYPE
SYNTAX SnmpAdminString(SIZE (1..64))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates a unique name used by agnStringToIndexTableId,
although it is not it's index."
::= { agnStringToIndexEntry 2 }
agnStringToIndexTableIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numeric Index of agnStringToIndexTableId."
::= { agnStringToIndexEntry 3 }
agnRowPointerTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnRowPointerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table holds information about a specific entry in a table.
For example, number of usages of this row."
::= { agnt 63 }
agnRowPointerEntry OBJECT-TYPE
SYNTAX AgnRowPointerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
INDEX {agnRowPointerIndex }
::= { agnRowPointerTable 1 }
AgnRowPointerEntry ::= SEQUENCE
{
agnRowPointerIndex OBJECT IDENTIFIER,
agnRowPointerNoOfUsages Unsigned32
}
agnRowPointerIndex OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The OBJECT IDENTIFIER of an entry in a table."
::= { agnRowPointerEntry 1 }
agnRowPointerNoOfUsages OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of usages of specific entry in a table, which is
pointed by agnRowPointerIndex.Usually, when the value of this counter is greater
than 0,the entry cannot be removed."
::= { agnRowPointerEntry 2 }
agnConfigVersion OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ASCII string of the Configuration Version."
::= { agnt 64 }
--services OBJECT IDENTIFIER ::= { radGen 3} See services.txt
radTransport OBJECT IDENTIFIER ::= { radGen 4}
--RAD transport tree
radTransportDomains OBJECT IDENTIFIER ::= { radTransport 1}
radTransportDomainSnmpEfmOam OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The SNMP over EFM OAM transport domain. The corresponding
transport address is of type RadTransportAddressEfmOam for
EFM OAM addresses (port)."
::= { radTransportDomains 1 }
RadTransportAddressType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A value that represents a transport domain. This is the
enumerated version of the transport domain registrations
in this MIB module. It was added in RAD MIB due to the fact
that it is not defined in Standard MIB.
The enumerated values have the following meaning:
unknown(0) unknown transport address type
efmOam (1) radTransportDomainSnmpEfmOam
This textual convention can be used to represent transport
domains in situations where a syntax of TransportDomain is
unwieldy (for example, when used as an index).
The usage of this textual convention implies that additional
transport domains can only be supported by updating this MIB
module."
SYNTAX INTEGER {
unknown(0),
efmOam (1)
}
RadTransportAddressEfmOam ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents a transport address consisting of an EFM OAM port number."
SYNTAX OCTET STRING (SIZE (4))
-- SYSTEM TRAPS
--NOTIFICATIONS
systemsEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for RAD products."
::= { systems 0 }
tftpStatusChangeTrap NOTIFICATION-TYPE
OBJECTS { tftpStatus }
STATUS current
DESCRIPTION
"This trap is sent whenever the status of tftp changed."
::= { systemsEvents 1 }
agnStatusChangeTrap NOTIFICATION-TYPE
OBJECTS {agnIndication }
STATUS current
DESCRIPTION
"This trap is sent whenever the state of the entity the agent is
responsible for changed.
TDM devices will send agnTestStatus variable to indicate the current test status."
::= { systemsEvents 2 }
prtStatusChangeTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent whenever the state of a port changed.
Attached, will be parameter/s that indicate the new port status.
The attached variables will be specified in the specifications
of the products supporting this trap."
::= { systemsEvents 3 }
swdlStatusResult NOTIFICATION-TYPE
OBJECTS {swdlStatusFileName}
STATUS current
DESCRIPTION
"This notification is sent when Software Down Load is finished.
The attached object indicates the File Name."
::= { systemsEvents 4 }
intSwdlSlotFileMismatch NOTIFICATION-TYPE
OBJECTS {intSwdlFileName}
STATUS current
DESCRIPTION
"This notification is sent when the card in the chosen slot doesn't match
the chosen file.
The attached object indicates the File Name."
::= { systemsEvents 5 }
agnCounterChange NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This notification is sent when the value of a specific Counter is changed.
Agent can send as attached object the updated Counter.
For details about this Counter and attached object, see spec of the relevant
application."
::= { systemsEvents 6 }
prtClkSrcChangeTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent upon any port clock change."
::= { systemsEvents 7 }
moduleFailTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent upon a module failure."
::= { systemsEvents 8 }
moduleInitFailTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent upon a module initialization failure."
::= { systemsEvents 9 }
clkSrcChangeTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent upon any change in Clock Source."
::= { systemsEvents 10 }
agnUploadDataTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent upon an upload data session termination.
For more details see product specification."
::= { systemsEvents 11 }
enrollmentTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is a periodically trap, which sent to manager
untill Agent get any response (Get or Set) from this manager."
::= { systemsEvents 12 }
agnPowerFailureTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent upon power failure. It is applicable for
the following devices:
1. Devices having one PS unit, which sense the failure in advance,
and still have time to send this trap before it goes off.
2. Devices having 2 PS units and send this trap in order to notify a
failure in one of the units."
::= { systemsEvents 13 }
agnFanFailureTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent upon fan failure/recovery."
::= { systemsEvents 14 }
agnSystemParameterChangeTrap NOTIFICATION-TYPE
OBJECTS {systemParameter}
STATUS current
DESCRIPTION
"This trap is sent upon any change of the systemParameter value."
::= { systemsEvents 15 }
-- CONFIG DATABASE CHECKSUM ERROR
agnConfigDBChecksumError NOTIFICATION-TYPE
OBJECTS {alarmSeverity}
STATUS current
DESCRIPTION
"This trap indicates that the database currently
stored in the non-volatile memory of the device is corrupted"
::= { systemsEvents 16 }
-- ALARM BUFFER OVERFLOW
agnAlarmBufferOverflow NOTIFICATION-TYPE
OBJECTS {alarmSeverity}
STATUS current
DESCRIPTION
"This trap indicates that the quantity of
alarm messages which have been written
in the alarm buffer, since the last clear command,
exceeds predefined threshold. (Buffer size)
The new alarms are overwriting the oldest alarms
(the first alarms written in the buffer).
For LA-110,threshold value is 200 alarms."
::= { systemsEvents 17 }
-- ALARM BUFFER CLEAR
agnAlarmBufferClear NOTIFICATION-TYPE
OBJECTS {alarmSeverity}
STATUS current
DESCRIPTION
"This trap indicates that
alarm buffer has been cleared."
::= { systemsEvents 18 }
-- PARAMETER CHANGES IN DB DUE TO UPGRADE PROCESS
agnParametersValueChanged NOTIFICATION-TYPE
OBJECTS {alarmSeverity}
STATUS current
DESCRIPTION
"This trap indicates that due to software upgrade,
some of the parameters are assigned new values"
::= { systemsEvents 19 }
-- (SHDSL) INTERFACE SW VERSION INCOMPATIBLE WITH HW
agnDriverSwMismatch NOTIFICATION-TYPE
OBJECTS {alarmSeverity,ifAlias}
STATUS current
DESCRIPTION
"There is mismatch between the SW driver and
the HW of the device uplink interface."
::= { systemsEvents 20 }
-- DEVICE SYNCHRONIZED ON LESS THAN CONFIGURED BANDWIDTH
agnActualLowRate NOTIFICATION-TYPE
OBJECTS {alarmSeverity}
STATUS current
DESCRIPTION
"The main link is synchronized
at a rate lower than expected."
::= { systemsEvents 21 }
xModemFileTransferStatusTrap NOTIFICATION-TYPE
OBJECTS { trapVal }
STATUS current
DESCRIPTION
"This trap is sent in the following cases:
- When an xModem File Transfer Session begins. In this case,
the trapVal.1 string sent will be: 'Start'.
- When an xModem File Transfer Session ends. In this case,
the trapVal.1 string sent will be one of the following,
according to the way the session ended :
- 'End: OK'
- 'End: Failed' "
::= { systemsEvents 22 }
agnStationClkFailureTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent upon Station Clock failure."
::= { systemsEvents 23 }
successfulLogin NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent when a user performed successful Login via
Terminal/Telnet/Web. This trap is used when the device is located
at End-User's premises while management is at Service Provider's
premises."
::= { systemsEvents 24 }
failedLogin NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent when a user tried to Login via Terminal/Telnet/Web
and failed. This trap is used when the device is located
at End-User's premises while management is at Service Provider's
premises."
::= { systemsEvents 25 }
modlChangeTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent whenever a module is inserted or removed.
The trap should include the new module type (e.g. modlParamType)."
::= { systemsEvents 26 }
licenseUpdateTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent whenever a license is successfully downloaded
or whenever a license's demo duration is expired."
::= { systemsEvents 27 }
agnClkSrcStateChangeTrap NOTIFICATION-TYPE
OBJECTS { agnClkSrcPortState }
STATUS current
DESCRIPTION
"The trap is sent upon change in Recovery Clock State."
::= { systemsEvents 28 }
agnSelfTestResultChangeTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"The trap is sent upon each change in the result of a Self State operation."
::= { systemsEvents 29 }
agnCurrClkStateChangeTrap NOTIFICATION-TYPE
OBJECTS { agnCurrClkState }
STATUS current
DESCRIPTION
"The trap is sent upon change in the state of the current (active) clock,
when it is a Recovery Clock."
::= { systemsEvents 30 }
agnClkSrcFrequencyAlarmTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"The trap is sent upon Recovered Clock Frequency alarm."
::= { systemsEvents 31 }
prtLoopDetectTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent upon Loop Detect (On/Off) on a certain port."
::= { systemsEvents 32 }
-- { systemsEvents 164 } is reserved for an internal trap.
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\trgen.txt
--
--Version: 4.0
--Date: 16.10.94
--By: Orly Nicklass
--File: TRGEN.TXT
--Last update: 05.12.95
trGen OBJECT IDENTIFIER ::= {radTokenRing 1}
--
agnRR OBJECT IDENTIFIER ::= {trGen 1} --agent RAD ring general information
ringTR OBJECT IDENTIFIER ::= { trGen 2 } --ring general information
segTR OBJECT IDENTIFIER ::= { trGen 3} -- segment general information
moduleTR OBJECT IDENTIFIER ::= {trGen 4} -- Module general information
prtTR OBJECT IDENTIFIER ::= {trGen 5 } --port general information
--
-- RADRing agent specific information
--
agnRRcoprocHwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ASCII string for description and display of the CML\IB hardware
version. If the entry is not applicable, it will display the string -NOT APPLICABLE-"
::= { agnRR 1 }
agnRRrecMode OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
slow(2),
fast(3),
notSupported(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The manager station can assist the agent in the autorecovery
process by setting this value to SLOW(1). This value indicates
the presence of old modules within the radring hub. Autorecovery
process will be faster for new modules. However it might fail
if set to FAST(2) and old modules are inserted."
::= { agnRR 2 }
agnRRmaskIBMalrt OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
disabled(2),
enabled(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is set to the value of Enabled(3),
Agent-traps that are not masked will also be sent to the IBM LAN manager
using IBM's Alert Transport Service Protocol.
This object is applicable only for TR agents."
::= { agnRR 3}
agnRRResetConfig OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3),
notSupported(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the value to ON(3)is interpreted as a reset command
for the agent NV Ram. When reset process is ended, a trap
will be issued. If the entry is not applicable, The value notSupported will be read."
::= { agnRR 4 }
agnRRSwReset OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Setting the value to ON(3)is interpreted as a software reset command
for the agent. When reset process is ended, a trap will be issued. "
::= { agnRR 5 }
agnRRRingReportMngr OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Setting the value to ON(3) is interpreted as assigning the duty of Ring Report
Manager on the agent "
::= { agnRR 6 }
agnRRSubSysCommState OBJECT-TYPE
SYNTAX INTEGER {
failed(2),
ok(3),
notSupported(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of communication between the two agent's
processors. The communication is failed when the CML/NM card is removed"
::= { agnRR 7 }
--
-- Ring information for the ring the agent is connected to. It is traffic information and
-- isolated error information.
--
ringResetStatistics OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the value of this attribute to ON(3) resets all the inband
statistics and error counters."
::= { ringTR 1 }
ringCurrentTraffic OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Momentary traffic for the last time interval. The traffic is expressed in
percents of the maximum Tokenring traffic ."
::= { ringTR 2 }
ringPeakTraffic OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximal traffic value since last reset of Agent or statistics.
Expressed in percents of the maximum Tokenring traffic."
::= { ringTR 3 }
ringTrafficTreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Traffic threshold value. When reached, a trap will be sent to the management
console. Expressed in percents of the maximum Tokenring traffic"
::= { ringTR 4 }
ringLineErrCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented when a frame
or token is copied or repeated by any of the
stations on the ring, the E bit is zero in the frame
or token and one of the following
conditions exists: 1) there is a
non-data bit (J or K bit) between the SD
and the ED of the frame or token, or
2) there is an FCS error in the frame."
::= { ringTR 5 }
ringLineErr OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented when a frame
or token is copied or repeated by any of the
stations on the ring, the E bit is zero in the frame
or token and one of the following
conditions exists: 1) there is a
non-data bit (J or K bit) between the SD
and the ED of the frame or token, or
2) there is an FCS error in the frame."
::= { ringTR 6 }
ringBurstErrCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented when any of the stations
on the ring detects the absence of transitions for five
half-bit timers (burst-five error)."
::= { ringTR 7 }
ringBurstErr OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented when any of the stations
on the ring detects the absence of transitions for five
half-bit timers (burst-five error)."
::= { ringTR 8 }
ringACFCErrCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented when any of the stations
on the ring receives an AMP or SMP frame in which A is
equal to C is equal to 0, and then receives
another SMP frame with A is equal to C is
equal to 0 without first receiving an AMP
frame. It denotes a station that cannot set
the AC bits properly."
::= { ringTR 9 }
ringACFCErr OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented when any of the stations
on the ring receives an AMP or SMP frame in which A is
equal to C is equal to 0, and then receives
another SMP frame with A is equal to C is
equal to 0 without first receiving an AMP
frame. It denotes a station that cannot set
the AC bits properly."
::= { ringTR 10 }
ringTotErrCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total of the above described errors"
::= { ringTR 11 }
ringTotErr OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total of the above described errors"
::= { ringTR 12 }
ringTotErrThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value of the total of the above described errors.When the threshold is reached
a trap indicating the status of the ring (SOFT ERROR)will be sent to the management station"
::= { ringTR 13}
ringStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
normal(2),
softError(3),
beacon(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the status of the LAN segment the agent is attached to:
Normal(2) - The LAN segment is operating normally
SoftError(3) - The Token ring LAN segment (ring) is experiencing
intermittent failures that temporarily harm the
ring's performance and cause data to be transmitted
more than ones.
Beaconing(4) - The ring is not operative; no data is transmitted."
::= { ringTR 14 }
ringConfigMsg OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Full configuration message coded in internal RAD application format.
This entry describes ring information. "
::= { ringTR 15 }
ringCurrentTrafficCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Momentary traffic for the last time interval. The traffic is expressed as bits per second."
::= { ringTR 16 }
--
-- Segments
--
segTRTable OBJECT-TYPE
SYNTAX SEQUENCE OF SegTREntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Segments."
::= { segTR 1}
segTREntry OBJECT-TYPE
SYNTAX SegTREntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table segTRTable."
INDEX { segTRID}
::= { segTRTable 1}
SegTREntry ::=
SEQUENCE {
segTRID
Integer32,
segTRLastSlot
Integer32,
segTRFirstSlot
Integer32,
segTRStatus
INTEGER
}
segTRID OBJECT-TYPE
SYNTAX Integer32 (1..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Segment unique identification number (internal). It is
the extreme left slot, marking the beginning of the
segment."
::= { segTREntry 1 }
segTRLastSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Location of the right most slot marking the end of the
segment. In the RADring hub it is slot number 20 or the slot
where end of segment module is inserted or the slot before
a beginning of a new segment. ( End of segment
module could be one with termination on or TIO, TFR, TCR etc.)"
::= { segTREntry 2 }
segTRFirstSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Location of the left most slot marking the beginning
of the segment. In the RADring hub it is slot number 1 or
the slot number following the end of segment module, or where
a repeater or TIO is inserted."
::= { segTREntry 3 }
segTRStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
beaconing(2),
normal(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the status of the segment :
Normal(3) - The segment is operating normally
Beaconing(2) - The ring is not operative; no data is transmitted.
Segment without inband module within its limit will display Unknown(1).
This entry is specially usefull when the hub is configured with multiple segments
and each segment is part of another net"
::= { segTREntry 4 }
--
-- Modules parameters structure
-- contains general information about the modules
--
mdlTRTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlTREntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Modules parameters structure
contains general information about the modules."
::= { moduleTR 1 }
mdlTREntry OBJECT-TYPE
SYNTAX MdlTREntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table mdlTRTable."
INDEX { mdlTRID }
::= { mdlTRTable 1 }
MdlTREntry ::=
SEQUENCE {
mdlTRID
Integer32,
mdlTRSegID
Integer32,
mdlTRType
INTEGER,
mdlTRHwVer
DisplayString,
mdlTRSwVer
DisplayString,
mdlTRTotalNoOfPrt
Integer32,
mdlTRSpecific
OBJECT IDENTIFIER
}
mdlTRID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot number where the module is inserted. Can not be greater
than chNoSlot"
::= { mdlTREntry 1 }
mdlTRSegID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The segment number where the module belongs to. One of the
segTRID values."
::= {mdlTREntry 2 }
mdlTRType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
empty(2),
tl4s(3),
tl4su(4),
tl4sd(5),
tl4cx(6),
tl4u(7),
tl2edu(8),
tl2eds(9),
tl2edsu(10),
tl2f(11),
tja(12),
tio(13),
tfr(14),
tfc1(15),
tfc2(16),
tcr(17),
tl4au(18),
tl4as(19),
tl4asd(20),
tl4asu(21),
tre1d(22),
tre(23),
tre8d(24),
stc1(25),
stc2(26),
ftc(27),
cmlib(28),
tl2fsat(29),
nonTR(30),
tau(31), -- for all TAUs type
rmu(32) -- for all RMUs type
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Indicates the type of the module connected at the specified slot number."
::= { mdlTREntry 3 }
mdlTRHwVer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ASCII string for description and display of the module's hardware version,
as it is known by the module's software. A manager can record his own
hardware upgrade."
::= { mdlTREntry 4 }
mdlTRSwVer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ASCII string for description and display of the module's
software version. A value of NOT APPLICABLE will be recorded
for module having no independent processor."
::= { mdlTREntry 5 }
mdlTRTotalNoOfPrt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry describes the number of possible ports/lobes/links
connection in the module (not all ports hardware should be active) ."
::= { mdlTREntry 6 }
mdlTRSpecific OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Object identifier of entity containing additional information
regarding this instance. This entry is type specific."
::= { mdlTREntry 7 }
--
-- TReral port table for any media type
--
prtTRTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtTREntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"TReral port table for any media type."
::= { prtTR 1 }
prtTREntry OBJECT-TYPE
SYNTAX PrtTREntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table prtTRTable."
INDEX { prtTRModuleID,prtTRID }
::= { prtTRTable 1 }
PrtTREntry ::=
SEQUENCE {
prtTRModuleID
Integer32,
prtTRID
Integer32,
prtTRFunctionality
INTEGER,
prtTRConnectorType
INTEGER,
prtTRAdminCmd
INTEGER,
prtTRActiveState
INTEGER,
prtTRTrapMaskEnable
INTEGER,
prtTRstatus
INTEGER,
prtTRCableProtectEnable
INTEGER,
prtTRCableState
INTEGER,
prtTRMACAddress
MacAddress,
prtTRSpecific
OBJECT IDENTIFIER
}
prtTRModuleID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the module(slot no.)this port is attached to."
::= { prtTREntry 1 }
prtTRID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port within its module."
::= { prtTREntry 2 }
prtTRFunctionality OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ringin(2) ,
ringout(3) ,
satellite(4),
lobe(5),
link(6),
tja(7),
none(8), -- N.C. repeater
smart-port(9) -- for RR-SAT if prtRRMode is set to smart-port
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the functionality of the port in a Token ring topology or other implementations."
::= { prtTREntry 3 }
prtTRConnectorType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
idc(2),
rj45(3),
srj45(4),
db9(5),
bnc(6),
foSt(7),
db25(8)
-- foSma(9),
-- foFc(10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of hardware connector in the port."
::= { prtTREntry 4 }
prtTRAdminCmd OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
disable(2),
enable(3),
short(4),
normal(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"By setting this attribute to DISABLE(2) or SHORT(4) the
management station can force this lobe/port/link-connection to be
removed and block any access to the network via this lobe/port/link.
It is not mandatory that a certain lobe/port/link will support all the
enumerated states. The state of the lobe/port/link is type specific and
indicated within the specific group"
::= { prtTREntry 5 }
prtTRActiveState OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3),
standby(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the electrical or optical activity
state of a lobe or the state of a port. Certain values may
not be applicable in some cases"
::= { prtTREntry 6 }
prtTRTrapMaskEnable OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this attribute is set to OFF by the management console the
agent starts sending the unmasked traps related to this port.
Otherwise no traps from this port are sent."
::= { prtTREntry 7 }
prtTRstatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
disabledManuall(2),
disabledAutorec(3),
disabledSecurity(4),
disableAuto(5),
disableFlip(6),
inserted(7),
bypass(8),
forcedloop(9),
trunkfail(10),
normal(11)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of this lobe/port
connection:
DISABLED - (2) to (6) indicates the reason for the disabled state.
INSERTED - (7)indicates that the lobe hardware inserts this lobe
into the ring , thus it becomes part of the ring.
BYPASS - (8)indicates that the ring bypasses this lobe and the
lobe hardware provides loopback connection towards the
station for media test purposes.
FORCEDLOOP - (9) indicates the port is in a loopback state and the
main ring is connected to the backup path.
TRUNKFAIL - (10) indicates that the ring connection is broken for a
repeater, converter or a cable protector.
NORMAL - (11) indicates the port is in normal condition.
It is not mandatory that a certain lobe/port will support all the
enumerated states."
::= { prtTREntry 8 }
prtTRCableProtectEnable OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3),
inhibit(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this attribute determines activation of the cable-fault
protection mechanism of TCR and the optical link mechanism of
TFR and TFC ."
::= { prtTREntry 9 }
prtTRCableState OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
failed(2),
normal(3),
remoteFailed(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this attribute determines the cable status
of TCR and the optical link mechanism of
TFR and TFC ."
::= { prtTREntry 10}
prtTRMACAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object is the specific MAC address
of this interface which uniquely identifies this Interface
on a ring."
::= { prtTREntry 11 }
prtTRSpecific OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Object identifier of entity containing additional information
regarding this instance. This entry is type specific."
::= { prtTREntry 12}
prtTRMacAddressTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtTRMacAddressEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"."
::= { prtTR 2 }
prtTRMacAddressEntry OBJECT-TYPE
SYNTAX PrtTRMacAddressEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table prtTRMacAddressTable."
INDEX { prtTRMacAddressModuleID,prtTRMacAddressPortID, prtTRMacAddressID}
::= { prtTRMacAddressTable 1 }
PrtTRMacAddressEntry ::=
SEQUENCE {
prtTRMacAddressModuleID
Integer32,
prtTRMacAddressPortID
Integer32,
prtTRMacAddressID
Integer32,
prtTRMACAddressValue
MacAddress
}
prtTRMacAddressModuleID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the module(slot no.)this port is attached to."
::= { prtTRMacAddressEntry 1 }
prtTRMacAddressPortID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port within its module."
::= { prtTRMacAddressEntry 2 }
prtTRMacAddressID OBJECT-TYPE
SYNTAX Integer32 (1..250)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A identifier of the MAC address in the list according to the ring order"
::= { prtTRMacAddressEntry 3 }
prtTRMACAddressValue OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" MAC address from the list of addresses connected to this port"
::= { prtTRMacAddressEntry 4 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\radring.txt
--
--Version: 4.00
--Original : 30.11.93
--Last revision: 05.12.95
--File: radring.txt
--
radRing OBJECT IDENTIFIER ::= {radTokenRing 2}
--
chasRR OBJECT IDENTIFIER ::= {radRing 1} -- Chassis information
segRR OBJECT IDENTIFIER ::= { radRing 2 } -- segment information
moduleRR OBJECT IDENTIFIER ::= { radRing 3 } --Module information
prtRR OBJECT IDENTIFIER ::= { radRing 4 } -- Port information
--
-- Chassis description for any object having to be surrounded by a frame
--
chType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This value indicates which type of enclosure the Rad agent is managing. The default value will be RadRing"
::= { chasRR 1 }
chNoSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicates the number of manageable slots in the chassis.
Not all slots must be occupied."
::= { chasRR 2 }
chPSPrimary OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
fault(3),
active(4),
recovered(5),
none(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of the main (primary) power
supply unit "
::= { chasRR 3 }
chPSSecondary OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off( 2),
fault(3),
active(4),
recovered(5),
none( 6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of the secondary power
supply unit"
::= { chasRR 4 }
chTemperature OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
exceed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates if the internal hub temperature exceeded
the permissible maximum "
::= { chasRR 5 }
chEtMainClock OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ok(2),
fault(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of Eternet repeater main clock
in RadRingII hub"
::= { chasRR 6 }
chEtSecClock OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ok(2),
fault(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of Eternet repeater secondary clock
in RadRingII hub"
::= { chasRR 7 }
--
-- RADRing segments' specific information
--
segRRSecurityTable OBJECT-TYPE
SYNTAX SEQUENCE OF SegRRSecEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RADRing segments' specific information"
::= { segRR 1}
segRRSecEntry OBJECT-TYPE
SYNTAX SegRRSecEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table segRRSecurityTable."
INDEX { segRRID, segRRSecID}
::= { segRRSecurityTable 1}
SegRRSecEntry ::=
SEQUENCE {
segRRID
Integer32,
segRRSecID
Integer32,
segRRSecEnable
INTEGER,
segRRSecurityPattern
MacAddress,
segRRSecurityMask
MacAddress
}
segRRID OBJECT-TYPE
SYNTAX Integer32 (1..21)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Segment unique identification number (internal). It is
the extreme left slot, marking the beginning of the
segment.
TR segment no.: 1 .. 20
Ethernet segment no.: 21."
::= { segRRSecEntry 1 }
segRRSecID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Segment's security unique identification number"
::= { segRRSecEntry 2 }
segRRSecEnable OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates whether the specific segment's security is active or not"
::= { segRRSecEntry 3 }
segRRSecurityPattern OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A six-octet (48 bit) pattern, where the masked bits of segTRSecurityMask
need to match the MAC address of each port within the segment. A Value of
all-zeros indicates no security."
::= { segRRSecEntry 4 }
segRRSecurityMask OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mask of the allowed MAC address that can be connected through
the ports within the segment"
::= { segRRSecEntry 5}
--
-- RADRing specific modules' information
--
mdlRRTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlRREntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RADRing specific modules' information"
::= { moduleRR 1 }
mdlRREntry OBJECT-TYPE
SYNTAX MdlRREntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table mdlRRTable."
INDEX { mdlRRid}
::= { mdlRRTable 1}
MdlRREntry ::=
SEQUENCE {
mdlRRid
Integer32,
mdlRRTLRstatus
INTEGER,
mdlRRtermination
INTEGER,
mdlRRReset
INTEGER,
mdlRRLed
OCTET STRING,
mdlRRSpeed
INTEGER,
mdlRRMngAutoDis
INTEGER,
mdlRRAutodisable
INTEGER,
mdlRRConfigMsg
OCTET STRING,
mdlRRMngState
INTEGER,
mdlRRType
INTEGER,
mdlRRHwVer
DisplayString,
mdlRRSwVer
DisplayString,
mdlRRSpecific
OBJECT IDENTIFIER
}
mdlRRid OBJECT-TYPE
SYNTAX Integer32 (1..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique number to identify the module. It indicates the slot
number the module is inserted in."
::= { mdlRREntry 1}
mdlRRTLRstatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the status of the setup on the TL-2/Exx
modules. When the value is ON, lobe one is the only active lobe. This entry
will have the value UNKNOWN for all other modules "
::= { mdlRREntry 2 }
mdlRRtermination OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Attribute describing the termination state as set by the switches on the
lobe modules"
::= { mdlRREntry 3 }
mdlRRReset OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is set to the value of ON(3),
the module performs software reset. Upon completion, a trap will
be issued to the management station and the value
will be set to OFF. This entry will have the value of UNKNOWN (1) for
modules without independent processors. This command should be masked
for the agent module"
::= { mdlRREntry 4 }
mdlRRLed OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the LEDs status in the module . Each led will be represented by 4 bits
where the first 2 bits will specify the status (NA, OFF, ON, BLINK), and the next two bits
will specify the color (RED, GREEN, YELLOW)"
::= { mdlRREntry 5}
mdlRRSpeed OBJECT-TYPE
SYNTAX INTEGER {
unknown(1), -- for WAN cards
fourMegabit(2),
sixteenMegabit(3),
tenMegabit(4) -- for Ethernet
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Attribute describing the bandwidth of the media as set by the module switches."
::= { mdlRREntry 6 }
mdlRRMngAutoDis OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3)
}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Attribute describing the setup of the MNG switch on the TL- Active cards. Value ON indicates
the ability of activating the auto-disable mechanism of the card via management command.
Value OFF indicates that the activation of the auto-disable mechanism of the card is according
to the switch setting.In this case the mdlRRAutodisable will not be available for write
operation. Applicable to Token Ring cards only.
Replaced by mdlRRMngState."
::= { mdlRREntry 7}
mdlRRAutodisable OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute can be set by the manager if the value of mdlRRMngAutoDis is ON. It
controls the behavior of the Active cards regarding the Auto-disable mechanism. All
ports will be in the same mode. Applicable to Token Ring cards only."
::= { mdlRREntry 8 }
mdlRRConfigMsg OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Full configuration message coded in internal RAD application format.
This entry describes module' configuration. "
::= { mdlRREntry 9 }
mdlRRMngState OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
disable(2),
enable(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" This entry indicates the setting of the module's switches. ENABLE means that the module
can accept management commands. "
::= { mdlRREntry 10 }
mdlRRType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
empty(2),
tl4s(3),
tl4su(4),
tl4sd(5),
tl4cx(6),
tl4u(7),
tl2edu(8),
tl2eds(9),
tl2edsu(10),
tl2f(11),
tja(12),
tio(13),
tfr(14),
tfc1(15),
tfc2(16),
tcr(17),
tl4au(18),
tl4as(19),
tl4asd(20),
tl4asu(21),
tre1d(22),
tre(23),
tre8d(24),
stc1(25),
stc2(26),
ftc(27),
cmlib(28),
tl2fsat(29),
-- WAN
taV24(30),
taV11(31),
wangVs(32),
ta3x74(33),
ta3x(34),
-- rr-sat
sat-asu(35),
sat-asd(36),
sat-su(37),
sat-sd(38),
-- ethernet
ep8t(39),
ep4taui(40),
ep4t2fl(41),
ep4tfl(42),
ep4fl(43),
-- epr
epr8t(45),
epr4taui(46),
epr4t2fl(47),
epr4tfl(48),
epr4fl(49),
-- rr
tl2fm(51),
ftc2(53),
mlbt(54),
mlbtf(55),
ftbDfo(56),
ftbSfo(57),
mbe8d(58),
mbe1d(59),
cmlibE(60)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the type of the module installed in the specified slot number."
::= { mdlRREntry 11}
mdlRRHwVer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ASCII string for description and display of the module's hardware version,
as it is known by the module's software. A manager can record his own
hardware upgrade."
::= { mdlRREntry 12 }
mdlRRSwVer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ASCII string for description and display of the module's
software version. A value of NOT APPLICABLE will be recorded
for a module having no independent processor."
::= { mdlRREntry 13 }
mdlRRSpecific OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Object identifier of entity containing additional information
regarding this instance. This entry is module type specific."
::= { mdlRREntry 14 }
--
-- Additional parameters that can be monitored for a segment with an inband module.
-- Module specific for Token Ring
mdlIBTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlIBEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Additional parameters that can be monitored for a segment
with an inband module. Module specific for Token Ring"
::= { moduleRR 2 }
mdlIBEntry OBJECT-TYPE
SYNTAX MdlIBEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table mdlIBTable."
INDEX { mdlIBid}
::= { mdlIBTable 1}
MdlIBEntry ::=
SEQUENCE {
mdlIBid
Integer32,
mdlIBsegID
Integer32,
mdlIBCorrelationEnable
INTEGER,
mdlIBAutorecEnable
INTEGER,
mdlIBAutorecResult
INTEGER,
mdlIBcommand
INTEGER,
mdlIBstate
INTEGER,
mdlIBagnt
INTEGER,
mdlIBIpAddress
IpAddress,
mdlIBLocalMacAddr
MacAddress,
mdlIBbrnInMacAddr
MacAddress,
mdlIBLocalAddrStatus
INTEGER,
mdlIBTrapMaskEnable
INTEGER
}
mdlIBid OBJECT-TYPE
SYNTAX Integer32 (1..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique number to identify the CML\IB module. It indicates the slot
number the module is inserted in"
::= { mdlIBEntry 1 }
mdlIBsegID OBJECT-TYPE
SYNTAX Integer32 (1..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique number to identify the segment where the CML\IB module
is inserted. It is one of the segTRID values."
::= { mdlIBEntry 2 }
mdlIBCorrelationEnable OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to ON(3), the in-band agent should perform
correlation each time a station enters/leaves the segment."
::= { mdlIBEntry 3 }
mdlIBAutorecEnable OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to ON(3), the in-band agent should perform
autorecovery each time a beacon status is detected."
::= { mdlIBEntry 4 }
mdlIBAutorecResult OBJECT-TYPE
SYNTAX INTEGER {
notStarted(1),
started(2),
segmentOk(3),
segmentFixed(4),
segmentClosed(5),
failed(6),
hubProblem(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When autorecovery is completed the result will be reported (3)..(7).
While in autorecovery process, started(2) will be reported.
Before autorecovery process, notStarted(1) will be reported."
::= { mdlIBEntry 5 }
mdlIBcommand OBJECT-TYPE
SYNTAX INTEGER {
noOp(1),
open(2),
reset(3),
close(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is set to the value of
open(2), the station should go into the
open state. The progress and success of
this command is given by the values of the
object mdlIBstate.
When this object is set to the value
of reset(3), then the station should do
a reset. On a reset, all MIB counters
should retain their values, if possible.
Other side effects depend on the hardware chip set.
When this object is set to the value
of close(4), the station should go into
the closed state by removing itself
from the ring.
Setting this object to a value of
no-op(1) has no effect.
For read operation, this object has always a
value of no-op(1). It is not permitted to apply this
command on an agent module."
::= { mdlIBEntry 6 }
mdlIBstate OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
opened(2),
closed(3),
opening(4),
closing(5),
badParam(6),
lobeFailed(7),
signalLoss(8),
insertionTimeout(9),
ringFailed(10),
beaconning(11),
duplicateMac(12),
requestFailed(13),
removeReceived(14),
budFailure(15),
initFailure(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current adapter status, which can
be used to diagnose fluctuating problems."
::= { mdlIBEntry 7 }
mdlIBagnt OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3),
standBy (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Indicates whether the specific inband module serves as:
- Active hub agent - (on)
- Ring Monitor (for TR module only) - (off)
- Standby agent - (standBy)"
::= { mdlIBEntry 8 }
mdlIBIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates IP address of the module if the module serves as
an agent of itself."
::= { mdlIBEntry 9}
mdlIBLocalMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object is the specific MAC address
of this interface which uniquely identifies this interface
on a ring.It is the address set by the management and
upon request it will replace the burn in address.
Non-canonical format."
::= { mdlIBEntry 10}
mdlIBLocalAddrStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object specifies whether the specific
MAC address of this interface was set by the local
management or it is the burn-in address in use."
::= { mdlIBEntry 11 }
mdlIBbrnInMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object is the specific Burn-in MAC address
of this interface which uniquely identifies this interface
on a ring. Non-canonical format."
::= { mdlIBEntry 12 }
mdlIBTrapMaskEnable OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this attribute is set to OFF by the management console, the
agent starts sending the unmasked traps related to this module.
Otherwise, no traps are sent by this module."
::= { mdlIBEntry 13 }
-- Special modules such as bridges/converters that are within the hub
--
mdlBRGTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlBRGEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Special modules such as bridges/converters that are within the hub"
::= { moduleRR 3 }
mdlBRGEntry OBJECT-TYPE
SYNTAX MdlBRGEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table mdlBRGTable."
INDEX { mdlBRGid}
::= { mdlBRGTable 1}
MdlBRGEntry ::=
SEQUENCE {
mdlBRGid
Integer32,
mdlBRGReady
INTEGER,
mdlBRGStatus
DisplayString,
mdlBRGLocation
INTEGER,
mdlBRGIpAddress
IpAddress,
mdlBRGMacAddr
MacAddress,
mdlBRGAdapterState
INTEGER,
mdlBRGBypassSw
INTEGER
}
mdlBRGid OBJECT-TYPE
SYNTAX Integer32 (1..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique number to identify the module. It indicates the slot
number the module is inserted in."
::= { mdlBRGEntry 1}
mdlBRGReady OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3),
blink(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry will have the value ON when packets can be transferred in the TRE module.
The value UNKNOWN will be used for all other modules where this characteristic is
not applicable"
::= { mdlBRGEntry 2}
mdlBRGStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the status of operation of the STC or FTC modules. For other modules
this value will read NOAP"
::= { mdlBRGEntry 3}
mdlBRGLocation OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
main(2),
remote(3),
secondary(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the configuration mode:
- for the TRE bridge (main/remote)
- for MLB-T, MLBT-F (main/secondary) "
::= { mdlBRGEntry 4}
mdlBRGIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates IP address of the module if the module serves as an agent of itself. For
all other modules the IP value will be 0.0.0.0"
::= { mdlBRGEntry 5}
mdlBRGMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object is the specific MAC address
of this interface which uniquely identifies this interface
on a ring."
::= { mdlBRGEntry 6}
mdlBRGAdapterState OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
opened(2),
closed(3),
opening(4),
closing(5),
badParam(6),
lobeFailed(7),
signalLoss(8),
insertionTimeout(9),
ringFailed(10),
beaconning(11),
duplicateMac(12),
requestFailed(13),
removeReceived(14),
budFailure(15),
initFailure(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current adapter status, which can
be used to diagnose fluctuating problems.
This object is applicable only for TR bridges
with adapter.
The value 'unknown' will be used for other
module types."
::= { mdlBRGEntry 7 }
mdlBRGBypassSw OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry is applicable only for FTB-D/FO module.
It describes the status of the Bypass Switch.
The value UNKNOWN will be used for all other modules where
this characteristic is not applicable"
::= { mdlBRGEntry 8}
-- Special "WAN" modules that are within the RadRing hub
--
mdlMMTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlMMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Special 'WAN' modules that are within the RadRing hub"
::= { moduleRR 4 }
mdlMMEntry OBJECT-TYPE
SYNTAX MdlMMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table mdlMMTable."
INDEX { mdlMMid}
::= { mdlMMTable 1}
MdlMMEntry ::=
SEQUENCE {
mdlMMid
Integer32,
mdlMMBertCmd
INTEGER
}
mdlMMid OBJECT-TYPE
SYNTAX Integer32 (1..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique number to identify the module. It indicates the slot
number the module is inserted in."
::= { mdlMMEntry 1}
mdlMMBertCmd OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this Object to ON, will start BERT test on all the channels that are currently in
Remote Loop. If the value of mdlRRMngState is disabled, this parameter is read-only
and reflects the module jumper setting. "
::= { mdlMMEntry 2}
-- "Ethernet" modules that are within the hub
--
mdlETTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlETEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"'Ethernet' modules that are within the hub"
::= { moduleRR 5 }
mdlETEntry OBJECT-TYPE
SYNTAX MdlETEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table mdlETTable."
INDEX { mdlMMid }
::= { mdlETTable 1}
MdlETEntry ::=
SEQUENCE {
mdlETid
Integer32,
mdlETSAmode
INTEGER
}
mdlETid OBJECT-TYPE
SYNTAX Integer32 (1..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique number to identify the module. It indicates the slot
number the module is inserted in. It is the same
as rptrGroupIndex in the Repeater MIB"
::= { mdlETEntry 1}
mdlETSAmode OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this Object to ON, will change the mode of operation
of the Ethernet card to a stand alone operation mode. It will
disconnect the card from the repeater bus. The rptrGroupOperStatus
parameter in the Repeater MIB is changed to other(1).
The parameter is read-only when the value of mdlRRMngState
is disabled"
::= { mdlETEntry 2 }
--
--RADRing specific port information
--
prtRRTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtRREntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RADRing specific port information"
::= { prtRR 1 }
prtRREntry OBJECT-TYPE
SYNTAX PrtRREntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table prtRRTable."
INDEX { prtRRmdlID, prtRRID }
::= { prtRRTable 1 }
PrtRREntry ::=
SEQUENCE {
prtRRmdlID
Integer32,
prtRRID
Integer32,
prtRRSecurityState
INTEGER,
prtRRSecurityEnable
INTEGER,
prtRRSecurityMask
MacAddress,
prtRRSecurityPattern
MacAddress,
prtRRJitterAttenEnable
INTEGER,
prtRRConfigMsg
OCTET STRING,
prtRRFlipAutoDisable
INTEGER,
prtRRSecurityMask2
MacAddress,
prtRRSecurityPattern2
MacAddress,
prtRRMode
INTEGER,
prtRRAttachment
INTEGER
}
prtRRmdlID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the module,(slot no.),this port is attached to."
::= { prtRREntry 1 }
prtRRID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port within its module."
::= { prtRREntry 2 }
prtRRSecurityState OBJECT-TYPE
SYNTAX INTEGER {
notactive(1),
active(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates whether a security check can be performed on
the specific port. This value is directly related to the
presence of an inband module in the segment where the port
belongs to and to activation of the correlation process."
::= { prtRREntry 3 }
prtRRSecurityEnable OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value indicates whether a security check should be performed.
Setting this value to ON(3) will activate the security mechanism
if and only if, the value of prtRRSecurityState is ACTIVE."
::= { prtRREntry 4 }
prtRRSecurityMask OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mask of the allowed MAC address that can be connected through
this port. The security of the individual port overwrites the
security of the segment where the port belongs to"
::= { prtRREntry 5 }
prtRRSecurityPattern OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A six-octet(48 bit) pattern, where the masked bits of prtRRSecurityMask
should match the MAC address."
::= { prtRREntry 6}
prtRRJitterAttenEnable OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this attribute determines activation of the
jitters Attenuation mechanism of repeater's port ."
::= { prtRREntry 7 }
prtRRConfigMsg OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Full configuration message coded in internal RAD application format.
This entry describes port' configuration. "
::= { prtRREntry 8 }
prtRRFlipAutoDisable OBJECT-TYPE
SYNTAX INTEGER {
noApplicable(1),
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Attribute describing the control on the flipping mechanism of a lobe .
Value ON indicates the ability of the lobe to auto disable itself when flipping occur.
Value OFF indicates that the auto disable mechanism should not be activated and the
lobe should stay in a flipping state.
This attribute applies on selected lobes (tl-2/f, or tl-2/fsat)"
::= { prtRREntry 9 }
prtRRSecurityMask2 OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mask of the allowed MAC address that can be connected through
this port. The security of the individual port overwrites the
security of the segment where the port belongs to"
::= { prtRREntry 10 }
prtRRSecurityPattern2 OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A six-octet(48 bit) pattern: where the masked bits of prtRRSecurityMask2
should match the MAC address."
::= { prtRREntry 11 }
prtRRMode OBJECT-TYPE
SYNTAX INTEGER
{
noApplicable (1),
smart-port (2),
port (3),
interRptrPort(4),
multiConnPort(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the port status of rr-sat card after the communication
is broken. When configured to smart-port, the port disables itself
when there is no management communication with attachment.
interRptrPort - this port is used to connect an external
repeater. No security can be set for this port.
MAC Address is set to 0. No traps 'MAC Address changed'
are generated.
multiConnPort - this port is used for connection of external
4 port repeater. 8 securities per port exist.
MAC Address is set to 0. No traps 'MAC Address changed'
are generated. "
::= { prtRREntry 12 }
prtRRAttachment OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
station(2),
sLau2(3),
sLau4(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the type of the port attachment. Smart attachment types
are applicable for rr-sat card only"
::= { prtRREntry 13 }
--
--RADRing specific WAN modules port information
--
prtMMTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtMMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RADRing specific WAN modules port information."
::= { prtRR 2 }
prtMMEntry OBJECT-TYPE
SYNTAX PrtMMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table prtMMTable."
INDEX { prtMMmdlID, prtMMID }
::= { prtMMTable 1 }
PrtMMEntry ::=
SEQUENCE {
prtMMmdlID
Integer32,
prtMMID
Integer32,
prtMMAdminCmd
INTEGER,
prtMMOperStatus
INTEGER,
prtMMTestStatus
INTEGER,
prtMMBertResult
INTEGER,
prtMMTrapMaskEnable
INTEGER
}
prtMMmdlID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the module(slot no.)this port is attached to."
::= { prtMMEntry 1 }
prtMMID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port (link) within its module."
::= { prtMMEntry 2 }
prtMMAdminCmd OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
locLoop(2),
remLoop(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the object to locLoop(2) or remLoop(3) will activate the corresponding test.
Value remLoop(3) activates the BERT test on the related link if mdlMMBertCmd
is set to on(3). Setting parameter to normal(1), restores the normal operation
of the link. The parameter is read-only when value of mdlRRMngState is disable"
::= { prtMMEntry 3 }
prtMMOperStatus OBJECT-TYPE
SYNTAX INTEGER {
operational(1),
locSyncLoss(2),
remSyncLoss(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reflects the Synchronization status. "
::= { prtMMEntry 4 }
prtMMTestStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
locLoop(2),
remLoop(3),
bert(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reflects the link status. When the object is set to the value of bert(4),
it means that the remote loopback is active too. "
::= { prtMMEntry 5 }
prtMMBertResult OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
fault(2),
ok(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object indicates the status of the last BERT test."
::= { prtMMEntry 6 }
prtMMTrapMaskEnable OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is set to OFF by the management console, the
agent starts sending the unmasked traps related to this module.
Otherwise, no traps are sent by this module."
::= { prtMMEntry 7 }
--
--RADRing specific Ethernet port information
--
prtETTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtETEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RADRing specific Ethernet port information"
::= { prtRR 3 }
prtETEntry OBJECT-TYPE
SYNTAX PrtETEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table prtETTable."
INDEX { prtETmdlID, prtETID }
::= { prtETTable 1 }
PrtETEntry ::=
SEQUENCE {
prtETmdlID
Integer32,
prtETID
Integer32,
prtETTrapMaskEnable
INTEGER
}
prtETmdlID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the module, (slot no.), this port is attached to."
::= { prtETEntry 1 }
prtETID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port within its module."
::= { prtETEntry 2 }
prtETTrapMaskEnable OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this attribute is set to OFF by the management console, the
agent starts sending the unmasked traps related to this port.
Otherwise, no traps are sent by this port."
::= { prtETEntry 3 }
--
-- RR Port Security Table (10.08.95)
--
prtRRSecTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtRRSecEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RR Port Security Table (10.08.95)"
::= { prtRR 4 }
prtRRSecEntry OBJECT-TYPE
SYNTAX PrtRRSecEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table prtRRSecTable."
INDEX { prtRRSecmdlID, prtRRSecPrtID, prtRRSecID }
::= { prtRRSecTable 1 }
PrtRRSecEntry ::=
SEQUENCE {
prtRRSecmdlID
Integer32,
prtRRSecPrtID
Integer32,
prtRRSecID
Integer32,
prtRRSecMask
MacAddress,
prtRRSecPattern
MacAddress
}
prtRRSecmdlID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the module,(slot no.),this port is
attached to."
::= { prtRRSecEntry 1 }
prtRRSecPrtID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port within its module."
::= { prtRRSecEntry 2 }
prtRRSecID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the security number within the port."
::= { prtRRSecEntry 3 }
prtRRSecMask OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mask of the allowed MAC address that can be connected through
this port. The security of the individual port overwrites the
security of the segment, the port belongs to"
::= { prtRRSecEntry 4 }
prtRRSecPattern OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A six-octet(48 bit) pattern, where the masked bits of
prtRRSecMask should match the MAC address."
::= { prtRRSecEntry 5}
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\fdx.txt
--
--Title: FDX MIB
--Version: 2.1...
--Date: 16.10.94
--By: Dan.R.
--File: FDX.TXT
--Comments: The FDX agent also supports the following Public MIBs:
-- MIB-II (RFC1213)
-- FDDI MIB (RFC 1285)
-- relevant parts of Lannet-60 MIB.
-- the RAD Station Group
-- Implementation of the Station group is current
-- for all manageable systems which support RAD Stations
radFddiStation OBJECT IDENTIFIER ::= { radFddi 1 }
radFddiStationsNumber OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of manageable Stations implemented in the box."
::= { radFddiStation 1 }
-- the FDDI concentrator table
radFddiStationTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadFddiStationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of FddiStation entries. The number of entries is
given by the value of radFddiStationsNumber. "
::= { radFddiStation 2 }
radFddiStationEntry OBJECT-TYPE
SYNTAX RadFddiStationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table radFddiStationTable."
INDEX { radFddiStationIndex }
::= { radFddiStationTable 1 }
RadFddiStationEntry ::=
SEQUENCE {
radFddiStationIndex
Integer32,
radFddiStationType
INTEGER,
radFddiStationBus1TestResult
INTEGER,
radFddiStationBus2TestResult
INTEGER,
radFddiStationTempDeInsertAction
Integer32,
radFddiStationPerformTest
INTEGER,
radFddiStationOpticalSwitchStatus -- was radFddiStationOpticalSwitchBypass
INTEGER
}
radFddiStationIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value for each Station. Its value ranges
between 1 and the value ofradFddiStationNumber."
::= { radFddiStationEntry 1 }
radFddiStationType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
singleAttachedStation(2),
dualAttachedStation(3),
singleAttachedConcentrator(4),
dualAttachedConcentrator(5),
nullAttachedConcentrator(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Indicates the type of the station."
::= { radFddiStationEntry 2 }
radFddiStationBus1TestResult OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
faulty(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Indicates the result of a test performed on Bus1."
::= { radFddiStationEntry 3 }
radFddiStationBus2TestResult OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
faulty(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Indicates the result of a test performed on Bus2."
::= { radFddiStationEntry 4 }
radFddiStationTempDeInsertAction OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This action provides temporary deinsertion of the root
station from the ring. Expressed in milliseconds."
::= { radFddiStationEntry 5 }
radFddiStationPerformTest OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A value ON of this attribute indicates that a test should be
performed upon the Station."
::= { radFddiStationEntry 6 }
radFddiStationOpticalSwitchStatus OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2),
notSupported(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A value ON of this attribute indicates that the Station
is in bypass mode."
::= { radFddiStationEntry 7 }
-- the RAD FDDI SMT table
radFddiSMTTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadFddiSMTEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of FddiSMT entries. The number of entries is
given by the value of snmpFddiSMTNumber. "
::= { radFddi 2 }
radFddiSMTEntry OBJECT-TYPE
SYNTAX RadFddiSMTEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table radFddiSMTTable."
INDEX { radFddiSMTIndex }
::= { radFddiSMTTable 1 }
RadFddiSMTEntry ::=
SEQUENCE {
radFddiSMTIndex
Integer32,
radFddiSMTStation
Integer32,
radFddiSMTCFState
INTEGER,
radFddiSMTLeftSlot
Integer32,
radFddiSMTRightSlot
Integer32
}
radFddiSMTIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value for each SMT. Its value ranges
between 1 and the value of snmpFddiSMTNumber."
::= { radFddiSMTEntry 1 }
radFddiSMTStation OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Station inside the box to which the
current SMT belongs. Its value ranges
between 1 and the value of radFddiStationNumber."
::= { radFddiSMTEntry 2 }
radFddiSMTCFState OBJECT-TYPE
SYNTAX INTEGER {
isolated(1),
localA(2),
localB(3),
localAB(4),
localS(5),
wrapA(6),
wrapB(7),
wrapAB(8),
wrapS(9),
cWrapA(10),
cWrapB(11),
cWrapS(12),
thru(13)
}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The attachement configuration for the Station. Extends the
range of values provided by the SNMP variable snmpFddiSMTCFState
from the SNMP FDDI MIB."
::= { radFddiSMTEntry 3 }
radFddiSMTLeftSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the slot number of the leftmost card on the concentrator
implemented inside the box and managed by the agent MAC."
::= { radFddiSMTEntry 4 }
radFddiSMTRightSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the slot number of the rightmost card on the concentrator
implemented inside the box and managed by the agent MAC. Note that
the MAC-agent card itself is not taken into consideration."
::= { radFddiSMTEntry 5 }
-- the RAD FDDI MAC table
radFddiMACTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadFddiMACEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of FddiMAC entries. The number of entries is
given by the value of snmpFddiMACNumber. "
::= { radFddi 3 }
radFddiMACEntry OBJECT-TYPE
SYNTAX RadFddiMACEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table radFddiMACTable."
INDEX { radFddiMACSMTIndex, radFddiMACIndex }
::= { radFddiMACTable 1 }
RadFddiMACEntry ::=
SEQUENCE {
radFddiMACSMTIndex
Integer32,
radFddiMACIndex
Integer32,
radFddiMACStation
Integer32,
radFddiMACTestResult
Integer32,
radFddiMACTokenCt
Counter32,
radFddiMACRingLoad
Integer32,
radFddiMACRingLoadBuffer
OCTET STRING,
radFddiMACRingLoadTrsh
Integer32,
radFddiMACRingLoadPeak
Integer32,
radFddiMACDownstreamNbr
OCTET STRING,
radFddiMACRingStatus
INTEGER,
radFddiMACRingUtilization
Integer32,
radFddiMACRingPeakUtilization
Integer32
}
radFddiMACSMTIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the SMT index associated with this MAC."
::= { radFddiMACEntry 1 }
radFddiMACIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value for each MAC. Its value ranges
between 1 and the value of snmpFddiMACNumber."
::= { radFddiMACEntry 2 }
radFddiMACStation OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Station inside the box to which the
current MAC belongs. Its value ranges
between 1 and the value of radFddiStationNumber."
::= { radFddiMACEntry 3 }
radFddiMACTestResult OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Indicates the result of a test performed on MAC.
The value is a sum. It takes the value 0 if the result of the
test is OK and if faults occur, 2 raised to a power is added
to the sum. The powers are according to the following table:
Fault Power
cardConfigError 0
GeneralError 1
MACError 2 "
::= { radFddiMACEntry 4 }
radFddiMACTokenCt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Token Counts - Refer to ANSI MAC {73}."
::= { radFddiMACEntry 5 }
radFddiMACRingLoad OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current traffic value. The
traffic is expressed in percents of the maximum FDDI traffic
in the range 1..20, expressed on a log(10)
scale ( value = 10*log10(percent) )."
::= { radFddiMACEntry 6 }
radFddiMACRingLoadBuffer OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Record of traffic for the last second with a resolution of 100 msec. The
traffic is expressed in percents of the maximum FDDI traffic and each
record contains 10 readings, in the range 1..20, expressed on a log(10)
scale ( value = 10*log10(percent) )."
::= { radFddiMACEntry 7 }
radFddiMACRingLoadTrsh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Traffic threshold value. When exceeded, a trap is send to the management
console. Expressed in percents of the maximum FDDI traffic, in the
range 1..20, expressed on a log(10) scale."
::= { radFddiMACEntry 8 }
radFddiMACRingLoadPeak OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximal traffic value since last reset of hub or relay. Expressed in per-
cents of the maximum FDDI traffic, in the range 1..20,
expressed on log(10) scale."
::= { radFddiMACEntry 9 }
radFddiMACDownstreamNbr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC's downstream neighbor's long individual MAC address. The value
shall be reported as '00 00 00 00 00 00' if it is unknown."
::= { radFddiMACEntry 10 }
radFddiMACRingStatus OBJECT-TYPE
SYNTAX INTEGER {
ringUp(1),
ringDown(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Attribute which summs the status of the ring controlled by the current
MAC."
::= { radFddiMACEntry 11 }
radFddiMACRingUtilization OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current traffic value. The traffic is expressed in percents of the maximum FDDI traffic."
::= { radFddiMACEntry 12 }
radFddiMACRingPeakUtilization OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Peak traffic value since las reset of the hub or relay. The traffic is expressed
in percents of the maximum FDDI traffic."
::= { radFddiMACEntry 13 }
-- the RAD FDDI Group table
radFddiGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadFddiGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of FddiGroup entries. The number of entries is
given by the value of snmpFddiGroupNumber. "
::= { radFddi 4 }
radFddiGroupEntry OBJECT-TYPE
SYNTAX RadFddiGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table radFddiGroupTable."
INDEX { radFddiGroupId }
::= { radFddiGroupTable 1 }
RadFddiGroupEntry ::=
SEQUENCE {
radFddiGroupId
Integer32,
radFddiGroupRedundancy
INTEGER,
radFddiGroupTopologyMode
INTEGER,
radFddiGroupTestResult
INTEGER,
radFddiGroupConfigStatus
INTEGER,
radFddiGroupAutoRightLoop
INTEGER,
radFddiGroupAutoLeftLoop
INTEGER,
radFddiGroupManRightLoop
INTEGER,
radFddiGroupManLeftLoop
INTEGER,
radFddiGroupOpticalSwitchStatus
INTEGER
}
radFddiGroupId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique ID of the group in radFddiGroupTable. Equivalent to slot number
in enclosures."
::= { radFddiGroupEntry 1 }
radFddiGroupRedundancy OBJECT-TYPE
SYNTAX INTEGER {
none(1),
double-bandwidth(2),
backup(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute shows the usage of the A/B pair of ports in Tree mode.
If the redundancy conditions are not fulfilled, value none(1) will be
returned.
If backup mode port A is a standby backup of port B, otherwise each of
them is connected to a separate bus."
::= { radFddiGroupEntry 2 }
radFddiGroupTopologyMode OBJECT-TYPE
SYNTAX INTEGER {
none(1),
tree(2),
ring(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defines the topology mode of the FDDI PHY card."
::= { radFddiGroupEntry 3 }
radFddiGroupTestResult OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
faulty(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Result of test performed upon an FDDI group. A value of faulty (1)
indicates a CPU or communication at module level."
::= { radFddiGroupEntry 4 }
radFddiGroupConfigStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
cardConfigErrorAB(2),
cardConfigErrorS(3),
switchTopologyError(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Indicates the configuration status of the module (group)."
::= { radFddiGroupEntry 5 }
radFddiGroupAutoRightLoop OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value ON of this attribute signifies that a hardware loop was
automatically created on a FDDI module which does not sense
the existence of another FDDI group on the right hand side."
::= { radFddiGroupEntry 6 }
radFddiGroupAutoLeftLoop OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value ON of this attribute signifies that a hardware loop was
automatically created on a FDDI module which does not sense
the existence of another FDDI group on the left hand side."
::= { radFddiGroupEntry 7 }
radFddiGroupManRightLoop OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON signifies a command to the hardware
to create a loop on the FDDI module which isolates the ring
from the right hand side."
::= { radFddiGroupEntry 8 }
radFddiGroupManLeftLoop OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON signifies a command to the hardware
to create a loop on the FDDI module which isolates the ring
from the left hand side."
::= { radFddiGroupEntry 9 }
radFddiGroupOpticalSwitchStatus OBJECT-TYPE
SYNTAX INTEGER {
not-present(1),
inserted(2),
not-inserted(3),
present(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the presence of the optical switch
and for existing optical switches describes the possibility of
auto-reconfiguration of path resources (MACs and
M-ports) in the case of bus fault or connection
disabling. If merge(2), resources will try to move
to another bus, if non-merge(1) resources are left
on their dedicated bus."
::= { radFddiGroupEntry 10 }
radFddiPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadFddiPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"."
::= { radFddi 5 }
radFddiPortEntry OBJECT-TYPE
SYNTAX RadFddiPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table radFddiPortTable."
INDEX { radFddiPortGroupID, radFddiPortID }
::= { radFddiPortTable 1 }
RadFddiPortEntry ::= SEQUENCE {
radFddiPortGroupID
Integer32,
radFddiPortID
Integer32,
radFddiPortTestResult
INTEGER,
radFddiPortNumberOfConnectedStations
Integer32,
radFddiPortConnectedStations
OCTET STRING,
radFddiPortCurrentPath
INTEGER,
radFddiPortFunctionalStatus
INTEGER
}
radFddiPortGroupID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ID of group to which the FDDI card belongs."
::= { radFddiPortEntry 1 }
radFddiPortID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique Id of the port in the radFddiPortEntry."
::= { radFddiPortEntry 2 }
radFddiPortTestResult OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
faulty(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the result of a test performed on a port."
::= { radFddiPortEntry 4 }
radFddiPortNumberOfConnectedStations OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of stations connected to the port."
::= { radFddiPortEntry 5 }
radFddiPortConnectedStations OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the configuration of the stations connected
to the port.The FDDI addresses of the stations are displayed in ring
order, starting with the address of the first station connected to the
port. The length of the string is equal to the value of
radFddiPortNumberOfConnectedStations multiplied by 8 (length of
FddiSMTStationIdType)."
::= { radFddiPortEntry 6 }
radFddiPortCurrentPath OBJECT-TYPE
SYNTAX INTEGER{
isolated(1),
local(2),
secondary(3),
primary(4),
concatenated(5),
thru(6)
}
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Current Path in FDDI port on PHY cards."
::= { radFddiPortEntry 8 }
radFddiPortFunctionalStatus OBJECT-TYPE
SYNTAX INTEGER{
ok(1),
lerAlarm(2),
lerCutoff(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fubctional status of the port according to value of link error
estimate relative to thresholds of alarm and cutoff."
::= { radFddiPortEntry 9 }
radFddiAgn OBJECT IDENTIFIER ::= { radFddi 6 }
-- the RAD Agent Group
-- Implementation of the Agent group is current
-- for all manageable systems which support RAD Stations
radFddiAgnPriSwDesc OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ASCII string for description and display of the Fddi agent software version."
::= { radFddiAgn 1 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\brggen.txt
--
--version 5.35
--Initial Version: 4.0
--Date: 16.10.94
--By: Debby Koren & Orly Nicklass
--File: brggen.txt
--Last update: 16-Jun-2008 By Eran Cohen
-- ----------------------------------------------------------------------------------
genBridge OBJECT IDENTIFIER ::= {radBridges 1 }
-- At the end of the MIB there is a definition of all RAD general traps for bridges.
radBridgeAction OBJECT-TYPE
SYNTAX INTEGER {
reset(1),
sendNetworkTab(2),
deleteNetworkTab(3),
sendRoutingTab(4), -- Level II
deleteRoutinTab(5),
sendLanTab(6),
deleteLanTab(7),
deleteArpTab(8),
sendArpTab(9),
deleteRouteTab(10), -- Level III
sendRouteTab(11),
deactivateAllMasks(12),
saveAllActiveMasks(13),
loadAndActivateAllMasksFromNVRAM(14),
clearAllMasksFromNVRAM(15),
defaultConfig(16),
resetNVRAM(17),
clearIPNVRAM(18),
noOp(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable enables the operator to perform one of the
specified actions on the tables maintained by the network device.
Send actions are not currently implemented. Not all actions can
be performed on all bridges."
::= { genBridge 1 }
radBridgeInactiveArpTimeOut OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable defines the maximum time period that can pass
between ARP requests concerning an entry in the ARP table.
After this time period, the entry is deleted from the table."
::= { genBridge 2 }
-- radBridgeMaskTab defines the format of RAD Bridge OLD masking tables
radBridgeMaskTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeMaskEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Mask tables enable definition of forwarding restrictions and
control of message flow in the internetwork. Each entry
in this table defines a mask statement consisting of up to
three mask definitions and an action defined by
radBridgeMaskOper. Different types of mask entries are supported,
as defined by radBridgeMaskType."
::= { genBridge 3 }
radBridgeMaskEntry OBJECT-TYPE
SYNTAX RadBridgeMaskEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table radBridgeMaskTable."
INDEX { radBridgeMaskType, radBridgeMaskIfIndex, radBridgeMaskNum }
::= { radBridgeMaskTable 1 }
RadBridgeMaskEntry ::= SEQUENCE {
radBridgeMaskType
INTEGER,
radBridgeMaskIfIndex
Integer32,
radBridgeMaskNum
Integer32,
radBridgeMaskDest
INTEGER,
radBridgeMaskPat1
OCTET STRING,
radBridgeMaskActiveBit1
OCTET STRING,
radBridgeMaskFrom1
INTEGER,
radBridgeMaskOffset1
Integer32,
radBridgeMaskCond1
INTEGER,
radBridgeMaskPat2
OCTET STRING,
radBridgeMaskActiveBit2
OCTET STRING,
radBridgeMaskFrom2
INTEGER,
radBridgeMaskOffset2
Integer32,
radBridgeMaskCond2
INTEGER,
radBridgeMaskPat3
OCTET STRING,
radBridgeMaskActiveBit3
OCTET STRING,
radBridgeMaskFrom3
INTEGER,
radBridgeMaskOffset3
Integer32,
radBridgeMaskCond3
INTEGER,
radBridgeMaskOper
INTEGER
}
radBridgeMaskType OBJECT-TYPE
SYNTAX INTEGER {
tx(1),
rx(2),
compress(3),
priority(4),
loadSharing(5),
facs(6),
codConnect(7),
codDisconnect(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defines the type of mask entry."
::= { radBridgeMaskEntry 1 }
radBridgeMaskIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the if Index of the interface to which the mask is applied."
::= { radBridgeMaskEntry 2 }
radBridgeMaskNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Mask entry number, defined by its line number in the mask
table."
::= { radBridgeMaskEntry 3 }
radBridgeMaskDest OBJECT-TYPE
SYNTAX INTEGER {
unassigned-cond (1),
broadcast-msge (2),
multicast-msge (3),
all-msge(4),
none(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the type of destination address carried by the frame
to which the mask will be applied. Unassigned-condition
deactivates the mask entry."
::= { radBridgeMaskEntry 4 }
radBridgeMaskPat1 OBJECT-TYPE
SYNTAX OCTET STRING -- (SIZE (2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes the mask field which is either a 16 bit binary pattern,
or four digit hexadecimal pattern."
::= { radBridgeMaskEntry 5 }
radBridgeMaskActiveBit1 OBJECT-TYPE
SYNTAX OCTET STRING -- (SIZE (2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the positions of the wild card characters (*)
in the radBridgeMaskPat1 field."
::= { radBridgeMaskEntry 6 }
radBridgeMaskFrom1 OBJECT-TYPE
SYNTAX INTEGER {
mac(1),
llc(2),
net(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Offset base of radBridgeMaskPat1 within the frame.
Net can be in some cases the data start point."
::= { radBridgeMaskEntry 7 }
radBridgeMaskOffset1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the radBridgeMaskPat1 offset within the frame (in bytes) from
the base defined in by radBridgeMaskForm1.The mask offset is an even
decimal number in the range of 0 to 1518."
::= { radBridgeMaskEntry 8 }
radBridgeMaskCond1 OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the logical condition of the mask pattern:
true - Condition is valid if at the position specified by
radBridgeMaskOffset1 the packet contains data that matches
the content of radBridgeMaskPat1.
false - Condition is valid if at the position specified by
radBridgeMaskOffset1 the packet contains data that does not
match the content of radBridgeMaskPat1."
::= { radBridgeMaskEntry 9 }
radBridgeMaskPat2 OBJECT-TYPE
SYNTAX OCTET STRING -- (SIZE (2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes the mask field which is either a 16 bit binary pattern,
or four digit hexadecimal pattern."
::= { radBridgeMaskEntry 10 }
radBridgeMaskActiveBit2 OBJECT-TYPE
SYNTAX OCTET STRING -- (SIZE (2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the positions of the wild card characters (*)
in the radBridgeMaskPat2 field."
::= { radBridgeMaskEntry 11 }
radBridgeMaskFrom2 OBJECT-TYPE
SYNTAX INTEGER {
mac (1),
llc (2),
net(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Offset base of radBridgeMaskPat2 within the frame.
Net can be in some cases the data start point."
::= { radBridgeMaskEntry 12 }
radBridgeMaskOffset2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the radBridgeMaskPat2 offset within the frame (in bytes) from
the base defined in by radBridgeMaskForm2.The mask offset is an even
decimal number in the range of 0 to 1518."
::= { radBridgeMaskEntry 13 }
radBridgeMaskCond2 OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the logical condition of the mask pattern:
true - Condition is valid if at the position specified by
radBridgeMaskOffset2 the packet contains data that matches
the content of radBridgeMaskPat2.
false - Condition is valid if at the position specified by
radBridgeMaskOffset2 the packet contains data that does not
match the content of radBridgeMaskPat2."
::= { radBridgeMaskEntry 14 }
radBridgeMaskPat3 OBJECT-TYPE
SYNTAX OCTET STRING -- (SIZE (2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes the mask field which is either a 16 bit binary pattern,
or four digit hexadecimal pattern."
::= { radBridgeMaskEntry 15 }
radBridgeMaskActiveBit3 OBJECT-TYPE
SYNTAX OCTET STRING -- (SIZE (2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the positions of the wild card characters (*)
in the radBridgeMaskPat3 field."
::= { radBridgeMaskEntry 16 }
radBridgeMaskFrom3 OBJECT-TYPE
SYNTAX INTEGER {
mac (1),
llc (2),
net (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Offset base of radBridgeMaskPat3 within the frame.
Net can be in some cases the data start point."
::= { radBridgeMaskEntry 17 }
radBridgeMaskOffset3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the radBridgeMaskPat3 offset within the frame (in bytes) from
the base defined in by radBridgeMaskForm3. The mask offset is an even
decimal number in the range of 0 to 1518."
::= { radBridgeMaskEntry 18 }
radBridgeMaskCond3 OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the logical condition of the mask pattern:
true - Condition is valid if at the position specified by
radBridgeMaskOffset3 the packet contains data that matches
the content of radBridgeMaskPat3
false - Condition is valid if at the position specified by
radBridgeMaskOffset3 the packet contains data that does not
match the content of radBridgeMaskPat3."
::= { radBridgeMaskEntry 19 }
radBridgeMaskOper OBJECT-TYPE
SYNTAX INTEGER {
block (1),
forward (2),
route (3),
forward-route (4),
high-priority (5),
noOp(6),
delete(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of action to be taken if the frame meets the
conditions of the mask.
noOp = disabled (mask remains on list, but is not active)
delete = mask is removed from the list. "
::= { radBridgeMaskEntry 20 }
radBridgeCOD OBJECT IDENTIFIER ::= {genBridge 4 }
radBridgeCODParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeCODEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of COD parameters "
::= { radBridgeCOD 1}
radBridgeCODEntry OBJECT-TYPE
SYNTAX RadBridgeCODEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each radBridgeCODEntry consists of the following parameters"
INDEX {radBridgeCODIfIndex}
::= { radBridgeCODParamTable 1 }
RadBridgeCODEntry ::= SEQUENCE {
radBridgeCODIfIndex
Integer32,
radBridgeCODManualConnect
INTEGER,
radBridgeCODMode
INTEGER,
radBridgeCODConnectDelay
Integer32,
radBridgeCODisConnectDelay
Integer32,
radBridgeCODImplicitSwitch
INTEGER,
radBridgeCODNumAccess
Counter32,
radBridgeCODTotalConnecTime
Integer32
}
radBridgeCODIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface to which this COD entry is applicable."
::= { radBridgeCODEntry 1 }
radBridgeCODManualConnect OBJECT-TYPE
SYNTAX INTEGER {
connect(1),
disconnect(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The management station can start connection manually
by setting this parameter"
::= { radBridgeCODEntry 2 }
radBridgeCODMode OBJECT-TYPE
SYNTAX INTEGER {
answer(1),
originate(2),
disable(3),
answerAndOriginate(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In answer mode only one incoming call may be accepted at a time. Other nodes
attempting to access the local modem will receive a busy signal until the
connection is terminated. (Answer mode has no difficulty supporting multiple
remote connections to one local port, as blocking multiple incoming calls is
just a modem function. Originate mode, on the other
hand will only support a single local port to remote port connection).
The disable parameter disables the COD utility for this interface.
Choosing any other mode will enable the COD utility."
::= { radBridgeCODEntry 3 }
radBridgeCODConnectDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The connect delay defines the minimum time period that
the link must stay disconnected, between 2 succesive
connections (in seconds)."
::= { radBridgeCODEntry 4 }
radBridgeCODisConnectDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The disconnect delay defines the minimum time period
the link must stay connected, between 2 succesive
disconnections (in seconds)."
::= { radBridgeCODEntry 5 }
radBridgeCODImplicitSwitch OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The inplicit switch allows the user to ignore implicit triggers provided
by the COD software."
-- DEFVAL { 1 }
::= { radBridgeCODEntry 6 }
radBridgeCODNumAccess OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of successful connections that have been established since
the COD has been reset."
::= { radBridgeCODEntry 7}
radBridgeCODTotalConnecTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of all the connect time intervals since the COD was reset."
::= { radBridgeCODEntry 8}
radBridgeCODTimeTriggerTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeCODTimeTriggerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of COD parameters "
::= { radBridgeCOD 2 }
radBridgeCODTimeTriggerEntry OBJECT-TYPE
SYNTAX RadBridgeCODTimeTriggerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each radBridgeCODTimeTriggerEntry consists of the following parameters"
INDEX { radBridgeCODTimeIfIndex, radBridgeCODDay, radBridgeCODTimeTriggerNum }
::= { radBridgeCODTimeTriggerTable 1 }
RadBridgeCODTimeTriggerEntry ::= SEQUENCE {
radBridgeCODTimeIfIndex
Integer32,
radBridgeCODDay
INTEGER,
radBridgeCODTimeTriggerNum
Integer32,
radBridgeCODTimeTriggerFrom
DisplayString,
radBridgeCODTimeTriggerTo
DisplayString,
radBridgeCODTimeTriggerStatus
INTEGER
}
radBridgeCODTimeIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface to which this COD Time Trigger entry is applicable."
::= { radBridgeCODTimeTriggerEntry 1}
radBridgeCODDay OBJECT-TYPE
SYNTAX INTEGER {
mon(1),
tue(2),
wed(3),
thu(4),
fri(5),
sat(6),
sun(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The day of the week in which the dial up connection operates."
::= { radBridgeCODTimeTriggerEntry 2 }
radBridgeCODTimeTriggerNum OBJECT-TYPE
SYNTAX Integer32 (1..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Every day of the week the user can configure 3 dial up connections."
::= { radBridgeCODTimeTriggerEntry 3 }
radBridgeCODTimeTriggerFrom OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time to start Dial Up connection, in format hh:mm."
::= {radBridgeCODTimeTriggerEntry 4 }
radBridgeCODTimeTriggerTo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time to terminate Dial Up connection, in format HH:MM."
::= {radBridgeCODTimeTriggerEntry 5 }
radBridgeCODTimeTriggerStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
invalid(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of a table entry."
::= { radBridgeCODTimeTriggerEntry 6 }
radBridgeCODTraffic OBJECT IDENTIFIER ::= { radBridgeCOD 3}
radBridgeCODTrafficTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeCODTrafficEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of COD Traffic trigger "
::= { radBridgeCODTraffic 1 }
radBridgeCODTrafficEntry OBJECT-TYPE
SYNTAX RadBridgeCODTrafficEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each radBridgeCODTrafficEntry consists of the following parameters."
INDEX {radBridgeCODProtocolType}
::= { radBridgeCODTrafficTable 1}
RadBridgeCODTrafficEntry ::= SEQUENCE {
radBridgeCODProtocolType
INTEGER,
radBridgeCODTrafficTriggerStatus
INTEGER }
radBridgeCODProtocolType OBJECT-TYPE
SYNTAX INTEGER {
ip(1),
ipx(2),
other(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Protocol Type of the Traffic Table"
::= { radBridgeCODTrafficEntry 1 }
radBridgeCODTrafficTriggerStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Command of Status of the Protocol Traffic Trigger"
::= { radBridgeCODTrafficEntry 2 }
radBridgeCODRemoteIPAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This is the Remote IP Address"
::= { radBridgeCODTraffic 2 }
radBridgeCODIPMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This is the Mask of the Remote IP Address"
::= { radBridgeCODTraffic 3 }
radBridgeCODTrafficTriggerProtType OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Protocol Type for the User Defined Protocol Traffic Trigger (3)."
::= { radBridgeCODTraffic 4 }
--COD Condition table
radBridgeCODCondTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeCODCondEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of COD Condition parameters "
::= { radBridgeCOD 4}
radBridgeCODCondEntry OBJECT-TYPE
SYNTAX RadBridgeCODCondEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each radBridgeCODCondEntry consists of the following parameters"
INDEX {radBridgeCODCondIfIndex}
::= { radBridgeCODCondTable 1 }
RadBridgeCODCondEntry ::= SEQUENCE {
radBridgeCODCondIfIndex
Integer32,
radBridgeCODOriginateConnectCondition
INTEGER,
radBridgeCODOriginateDisConnectCondition
INTEGER,
radBridgeCODOriginateDisConnectDelay
Integer32,
radBridgeCODAnswerConnectCondition
INTEGER,
radBridgeCODSpecificOnTrafficOIDCondition
OBJECT IDENTIFIER,
radBridgeCODDisConnectMinimunFramesNumber
Integer32
}
radBridgeCODCondIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface, this COD entry is applicable to."
::= { radBridgeCODCondEntry 1 }
radBridgeCODOriginateConnectCondition OBJECT-TYPE
SYNTAX INTEGER {
onPowerOn (1),
whenAnyStationOnLan (2),
onTraffic (3),
onManualConnect (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This condition, allows the user to specify the
condition under which the link is connected.
The options are
onPowerOn - On power on.
whenAnyStationOnLan - When any station on lan.
onTraffic - On traffic. The user can specify the
condition/s for connection.
The connection will be defined in
CODSpecificOnTrafficConditionOID .
onManualConnect - depends on radBridgeCODManualConnect
OBJECT-TYPE (=connect).
"
::= { radBridgeCODCondEntry 2 }
radBridgeCODOriginateDisConnectCondition OBJECT-TYPE
SYNTAX INTEGER {
noStationOnLan (1),
onTraffic (2),
onDelayFromConnectionOnRequest (3),
onManualDisConnect (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This condition allows the user to specify the
condition under which the link is disconnected.
The options are:
noStationOnLan - When there is no station on lan.
Counts 15 minutes from the point the last
frame from lan has been received. If no
frame have been transmitted on lan by the
end of this period, disconnect the connection.
onTraffic - On traffic. The user can specify the
condition/s for disconnection.
The disconnection will be defined in
CODSpecificOnTrafficConditionOID .
onDelayFromConnectionOnRequest -
On Delay From Connection On Request .
The delay time period will be defined in
CODOriginateDisConnectDelay .
onManualDisConnect - depends on radBridgeCODManualConnect
OBJECT-TYPE (=disconnect).
"
::= { radBridgeCODCondEntry 3 }
radBridgeCODOriginateDisConnectDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Delay time in seconds. "
::= { radBridgeCODCondEntry 4 }
radBridgeCODAnswerConnectCondition OBJECT-TYPE
SYNTAX INTEGER {
onPowerOn (1),
whenAnyStationOnLan (2),
onTraffic (3),
onManualConnect (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CODCondAnswerConnect allows the user to specify
the condition under which the link is connected.
The options are:
onPowerOn - On power on.
whenAnyStationOnLan - When any station on lan.
onTraffic - On traffic. The user can specify the
condition/s for connection.
The connection will be defined in
CODSpecificOnTrafficConditionOID .
onManualConnect - depends on radBridgeCODManualConnect
OBJECT-TYPE .
"
::= { radBridgeCODCondEntry 5 }
radBridgeCODSpecificOnTrafficOIDCondition OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference to a specific entry in the
radBridgeMaskTable, which describes the
particular COD condition .
If Connect or Disconnect Conditions are not
onTraffic, its value should be set to the
OBJECT IDENTIFIER { 0 0 }. "
::= { radBridgeCODCondEntry 6 }
radBridgeCODDisConnectMinimunFramesNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frames rate."
::= { radBridgeCODCondEntry 7 }
--The IPX following objects define the Spoofing
radBridgeIPX OBJECT IDENTIFIER ::= {genBridge 5 }
radBridgeIPXdriver OBJECT IDENTIFIER ::= {radBridgeIPX 1 }
radBridgeIPXRip OBJECT IDENTIFIER ::= {radBridgeIPX 2 }
radBridgeIPXSap OBJECT IDENTIFIER ::= {radBridgeIPX 3 }
radBridgeIPXForwarding OBJECT-TYPE
SYNTAX INTEGER {
forwarding(1),
not-forwarding(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The indication of whether this entity is acting as an IPX
gateway in respect to the forwarding of datagrams received by,
but not addressed to, this entity. IPX gateways forward
datagrams. IPX hosts do not. Note that changing this parameter
requiers RESET of the router."
-- DEFVAL { 1 }
::= { radBridgeIPXdriver 1 }
radBridgeIPXRipOutPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets transmitted by RIP."
::= { radBridgeIPXRip 1 }
radBridgeIPXRipInPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received by RIP. This will include
any packets that are subsequently discarded."
::= { radBridgeIPXRip 2 }
radBridgeIPXRipInDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received packets discarded by RIP."
::= { radBridgeIPXRip 3 }
radBridgeIPXRipTblNoOfEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max number of entries that exist in the RIP routing table."
::= { radBridgeIPXRip 4 }
radBridgeIPXRipTblBcastTrigUpdateInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The default time interval (in seconds)between triggered RIP updates on
a broadcast type interface. A triggered update occurs when a change is
detected in the routing database. This time interval delays the
broadcasting of these updates so that changes on the network will
not result in a lot of triggered updates."
::= { radBridgeIPXRip 5 }
radBridgeIPXRipTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeIPXRipTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The routing table used by RIP to calculate routes to remote
desination networks."
::= { radBridgeIPXRip 6 }
radBridgeIPXRipTableEntry OBJECT-TYPE
SYNTAX RadBridgeIPXRipTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The routing information for one of this entity's destination networks."
INDEX { radBridgeIPXRipDestNetwork,
radBridgeIPXRipPolicy }
::= { radBridgeIPXRipTable 1 }
RadBridgeIPXRipTableEntry ::= SEQUENCE {
radBridgeIPXRipDestNetwork
OCTET STRING,
radBridgeIPXRipPolicy
INTEGER,
radBridgeIPXRipForwardingRouter
OCTET STRING,
radBridgeIPXRipNIC
Integer32,
radBridgeIPXRipTickMetric
Integer32,
radBridgeIPXRipHopMetric
Integer32,
radBridgeIPXRipAgingTime
TimeTicks,
radBridgeIPXRipValueStatus
INTEGER,
radBridgeIPXRipForwardType
INTEGER
}
radBridgeIPXRipDestNetwork OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The destination network address to which this entry's
routing information pertains."
::= {radBridgeIPXRipTableEntry 1 }
radBridgeIPXRipPolicy OBJECT-TYPE
SYNTAX INTEGER {
main(1),
alternate(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A value specifying the precidence of the route. A value of
zero means that the route is the best route, a value of one
means that the route is the second best route and so on."
::= { radBridgeIPXRipTableEntry 2 }
radBridgeIPXRipForwardingRouter OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPX node address of the next hop (router) for the
entry's associated destination network."
::= { radBridgeIPXRipTableEntry 3 }
radBridgeIPXRipNIC OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An interface identifier specifying what IPX interface the
next hop can be found on."
::= { radBridgeIPXRipTableEntry 4 }
radBridgeIPXRipTickMetric OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The metric, in terms of transit time, associated with the route
given by the entry. This time is in terms of 1/18ths of a
second."
::= { radBridgeIPXRipTableEntry 5 }
radBridgeIPXRipHopMetric OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The metric, in terms of distance , associated with the route
given by the entry."
::= { radBridgeIPXRipTableEntry 6 }
radBridgeIPXRipAgingTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last time that the entry was updated. The time will be
provided in terms of the MIB-I object sysUpTime."
::= {radBridgeIPXRipTableEntry 7 }
radBridgeIPXRipValueStatus OBJECT-TYPE
SYNTAX INTEGER {
static(1),
dynamic(2),
invalid(3),
semiDynamic(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The entry status value; whether the entry is permanent (added
statically), reachable or unreachable. In the latter two cases
it would be added by RIP. A semiDynamic entry is an entry
enterd manualy by the user and can be updated by the router."
::= { radBridgeIPXRipTableEntry 8 }
radBridgeIPXRipForwardType OBJECT-TYPE
SYNTAX INTEGER {
other (1), -- not specified by this MIB
local (2), -- local interface
remote (3) -- remote destination
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of route. Note that local(2) refers to a route for which the
next hop is the final destination; remote(3) refers to a route
for which the next hop is not the final destination."
::= {radBridgeIPXRipTableEntry 9 }
radBridgeIPXRipInfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeIPXRipInfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The RIP interface table."
::= { radBridgeIPXRip 7 }
radBridgeIPXRipInfEntry OBJECT-TYPE
SYNTAX RadBridgeIPXRipInfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry corresponds to one ifindex."
INDEX { radBridgeIPXRipInfIfIndex}
::= { radBridgeIPXRipInfTable 1 }
RadBridgeIPXRipInfEntry ::= SEQUENCE {
radBridgeIPXRipInfIfIndex
Integer32,
radBridgeIPXRipInfBcastUpdate
Integer32,
radBridgeIPXRipInfAgeMultiplier
Integer32
}
radBridgeIPXRipInfIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value of Ifindex is same as radBridgeIPXIfIndex in the
IPX Interface Table."
::= { radBridgeIPXRipInfEntry 1 }
radBridgeIPXRipInfBcastUpdate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The RIP periodic update interval, in seconds. Zero value
corresponds to infinite interval."
-- DEFVAL {60}
::= { radBridgeIPXRipInfEntry 2 }
radBridgeIPXRipInfAgeMultiplier OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The holding multiplier for information received in RIP
periodic updates. Zero value corresponds to infinite aging time."
-- DEFVAL {3}
::= { radBridgeIPXRipInfEntry 3 }
radBridgeIPXSapOutPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets transmitted by SAP."
::= { radBridgeIPXSap 1 }
radBridgeIPXSapInPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received by SAP. This will include
any packets that are subsequently discarded."
::= { radBridgeIPXSap 2 }
radBridgeIPXSapInDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received packets discarded by SAP."
::= { radBridgeIPXSap 3 }
radBridgeIPXSapTblNoOfEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max number of entries that exist in the SAP Server
Information table."
::= { radBridgeIPXSap 4 }
radBridgeIPXSapTblBcastTrigUpdateInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The default time interval (in seconds) between triggered SAP updates on a
broadcast style interface. A triggered update occurs when a
change is detected in the service database. This time interval
delays the transmission of these updates so that changes on the
network will not result in a lot of triggered updates."
::= { radBridgeIPXSap 5 }
radBridgeIPXSapTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeIPXSapTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Server Information table is used by SAP to store information
of services which are available on the internetwork."
::= { radBridgeIPXSap 6 }
radBridgeIPXSapTableEntry OBJECT-TYPE
SYNTAX RadBridgeIPXSapTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The server information for one of this entity's server entries."
INDEX { radBridgeIPXSapServerType,
radBridgeIPXSapName }
::= { radBridgeIPXSapTable 1 }
RadBridgeIPXSapTableEntry ::= SEQUENCE {
radBridgeIPXSapServerType
Integer32,
radBridgeIPXSapName
DisplayString,
radBridgeIPXSapNetwork
OCTET STRING,
radBridgeIPXSapNode
OCTET STRING,
radBridgeIPXSapSocket
Integer32,
radBridgeIPXSapHopsToServer
Integer32,
radBridgeIPXSapNIC
Integer32,
radBridgeIPXSapAgingTime
TimeTicks,
radBridgeIPXSapStatus
INTEGER
}
radBridgeIPXSapServerType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the server for which this entry pertains."
::= { radBridgeIPXSapTableEntry 1 }
radBridgeIPXSapName OBJECT-TYPE
SYNTAX DisplayString (SIZE(48))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the server for which this entry pertains."
::= { radBridgeIPXSapTableEntry 2 }
radBridgeIPXSapNetwork OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPX network address of the host on which this server exists."
::= { radBridgeIPXSapTableEntry 3 }
radBridgeIPXSapNode OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPX node address of the host on which this server exists."
::= { radBridgeIPXSapTableEntry 4 }
radBridgeIPXSapSocket OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPX socket number that is being used by the server to
which this entry pertains."
::= { radBridgeIPXSapTableEntry 5 }
radBridgeIPXSapHopsToServer OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of hops to the entity on which this server exists."
::= { radBridgeIPXSapTableEntry 6 }
radBridgeIPXSapNIC OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An Network Interface Card identifier specifying what IPX
interface the next hop can be found on."
::= { radBridgeIPXSapTableEntry 7 }
radBridgeIPXSapAgingTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last time that the entry was updated. The time will be
provided in terms of the MIB-I object sysUpTime."
::= { radBridgeIPXSapTableEntry 8 }
radBridgeIPXSapStatus OBJECT-TYPE
SYNTAX INTEGER {
permanent(1),
dynamic(2),
invalid(3),
semiDynamic(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of the entry."
::= { radBridgeIPXSapTableEntry 9 }
radBridgeIPXSapInfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeIPXSapInfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Sap interface table."
::= { radBridgeIPXSap 7 }
radBridgeIPXSapInfEntry OBJECT-TYPE
SYNTAX RadBridgeIPXSapInfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry corresponds to one ifindex."
INDEX {radBridgeIPXSapInfIfIndex}
::= { radBridgeIPXSapInfTable 1 }
RadBridgeIPXSapInfEntry ::= SEQUENCE {
radBridgeIPXSapInfIfIndex
Integer32,
radBridgeIPXSapInfBcastUpdate
Integer32,
radBridgeIPXSapInfAgeMultiplier
Integer32
}
radBridgeIPXSapInfIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value of Ifindex is same as radBridgeIPXIfIndex in the
IPX Interface Table."
::= { radBridgeIPXSapInfEntry 1 }
radBridgeIPXSapInfBcastUpdate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SAP periodic update interval, in seconds. Zero value
corresponds to infinite interval."
-- DEFVAL {60}
::= { radBridgeIPXSapInfEntry 2 }
radBridgeIPXSapInfAgeMultiplier OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The holding multiplier for information received in SAP
periodic updates. Zero value corresponds to infinite aging time."
-- DEFVAL {3}
::= { radBridgeIPXSapInfEntry 3 }
-- radMaskingTab defines the new format of RAD Bridge masking tables
GenAddress ::= OCTET STRING (SIZE(12))
newMasking OBJECT IDENTIFIER ::= {genBridge 6 }
maskingMaxEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of entries in the masking table."
::= { newMasking 1 }
maskingCurrentEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of entries in the mask table."
::= { newMasking 2 }
maskingTable OBJECT-TYPE
SYNTAX SEQUENCE OF MaskingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the new masking scheme.
Mask tables enable definition of forwarding restrictions and
control of message flow in the internetwork. Each entry
in this table defines a mask statement and an action defined by
maskingOperation."
::= { newMasking 3 }
maskingEntry OBJECT-TYPE
SYNTAX MaskingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the mask table."
INDEX { maskingType, maskingIfIndex, maskingIndex }
::= { maskingTable 1 }
MaskingEntry ::= SEQUENCE {
maskingType
INTEGER,
maskingIfIndex
Integer32,
maskingIndex
Integer32,
maskingProtocolType
INTEGER,
maskingSmartMaskOID
OBJECT IDENTIFIER,
maskingFrameType
INTEGER,
maskingFrameTypeCondition
INTEGER,
maskingSourceAddress
GenAddress,
maskingSourceActiveBits
GenAddress,
maskingSourceMacOrNet
INTEGER,
maskingSourceCondition
INTEGER,
maskingDestAddress
GenAddress,
maskingDestActiveBits
GenAddress,
maskingDestMacOrNet
INTEGER,
maskingDestCondition
INTEGER,
maskingLowLevelProt
INTEGER,
maskingLowLevelProtCondition
INTEGER,
maskingHighLevelProt
Integer32,
maskingHighLevelProtCondition
INTEGER,
maskingPortNum
Integer32,
maskingPortNumCondition
INTEGER,
maskingOperation
INTEGER,
maskingSrcPortNum
Integer32,
maskingSrcPortNumCondition
INTEGER
}
maskingType OBJECT-TYPE
SYNTAX INTEGER {
tx (1),
rx (2),
compress(3),
priority(4),
loadSharing(5),
facs(6),
codConnect(7),
codDisconnect(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defines the type of mask entry. "
::= { maskingEntry 1 }
maskingIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the ifIndex of the interface to which the mask is applied."
::= { maskingEntry 2 }
maskingIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index to the masking table. This number should not be greater than maskingMaxEntries"
::= { maskingEntry 3 }
maskingProtocolType OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
ip (2),
ipx (3),
sna (4),
netbios (5),
apple (6),
dec (7),
all (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The base protocol for masking. IPX, IP, others."
::= { maskingEntry 4 }
maskingSmartMaskOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference to a specific Smart mask table (old radBridgeMaskTable)
which enables a more specific mask type.
If this information is not available, its value
should be set to the OBJECT IDENTIFIER { 0 0 }. "
::= { maskingEntry 5 }
maskingFrameType OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
all (2),
broadcast (3),
multicast (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables the user to decide about frame type
* all frame
* just broadcast
* just multicast."
::= { maskingEntry 6 }
maskingFrameTypeCondition OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the logical condition of the mask pattern:
true - Condition is valid if at the position specified by
maskingFrameType the packet contains data that matches
the content of maskingFrameType.
fa lse - Condition is valid if at the position specified by
maskingFrameType the packet contains data that does not
match the content of maskingFrameType."
::= { maskingEntry 7 }
maskingSourceAddress OBJECT-TYPE
SYNTAX GenAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The source address is according to the maskingMacOrNet and
maskingProtocolType variables.
In case of 'MAC' enter 6 bytes (48 bit) of source address.
In case of 'NET'
if the maskingProtocolType is IP, this is the IP address
if the maskingProtocolType is IPX, this is the IPX address
(nnnnmmmmmmss)
nnnn - IPX net address
mmmmmm - Node address (Mac)
ss - IPX socket
In case of 'Apple'
nn - net address (4 nibbles)
ss - socket (4 nibbles)."
::= { maskingEntry 8 }
maskingSourceActiveBits OBJECT-TYPE
SYNTAX GenAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the positions of the wild card characters (*)
in the maskingSourceAddress field. Only the 1's bit will be taken in
considerations."
::= { maskingEntry 9 }
maskingSourceMacOrNet OBJECT-TYPE
SYNTAX INTEGER {
macAddress (1),
netAddress (2),
ipRange (3),
appleAddress(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The variable maskingSourceAddress and maskingSourceActiveBits
will be treated as MAC, or NET address.
- If maskingProtocolType = 'all', 'sna', 'netbios', dec or
'unknown', the maskingSourceMacOrNet can be macAddress only!
- If maskingProtocolType = 'ip' the
maskingSourceMacOrNet can be macAddress or netAddress or
appleAddress.
- If maskingProtocolType = 'ipx', the
maskingSourceMacOrNet can be either macAddress or netAddress.
- If maskingProtocolType = 'apple', the
maskingSourceMacOrNet can be either macAddress or appleAddress."
::= { maskingEntry 10 }
maskingSourceCondition OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the logical condition of the mask pattern:
true - Condition is valid if at the position specified by
maskingSourceAddress (in conjunction with maskingSourceActiveBits)
the packet contains data that matches the content of maskingSourceAddress.
false - Condition is valid if at the position specified by
maskingSourceAddress (in conjunction with maskingSourceActiveBits)
the packet contains data that does not match the content of
maskingSourceAddress."
::= { maskingEntry 11 }
maskingDestAddress OBJECT-TYPE
SYNTAX GenAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If maskingFrameType = broadcast or multicast, this object
is NOT APPLICABLE.
If maskingFrameType = all or unknown, this object is
applicable.
The destination address is according to the maskingMacOrNet and maskingProtocolType variables.
In case of 'MAC' enter 6 bytes (48 bit) of source address.
In case of 'NET'
if the maskingProtocolType is IP, this is the IP address
if the maskingProtocolType is IPX, this is the IPX address
(nnnnmmmmmmss)
nnnn - IPX net address
mmmmmm - Node address (Mac)
ss - IPX socket.
In case of 'Apple'
nn - net address (4 nibbles)
ss - socket (4 nibbles).
The IPX socket entered here has priority over the value of
maskingLowLevelProt, when it is ipxRip, ipxSap or ipxSpx,
unless the entered IPX socket is don't care. "
::= { maskingEntry 12 }
maskingDestActiveBits OBJECT-TYPE
SYNTAX GenAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If maskingFrameType = broadcast or multicast, this object
is NOT APPLICABLE.
If maskingFrameType = all or unknown, this object is
applicable.
Specifies the positions of the wild card characters (*)
in the maskingDestAddress field. Only the 1's bit will be taken in
considerations."
::= { maskingEntry 13 }
maskingDestMacOrNet OBJECT-TYPE
SYNTAX INTEGER {
macAddress (1),
netAddress (2),
ipRange (3),
appleAddress(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If maskingFrameType = broadcast or multicast, this object
is NOT APPLICABLE.
If maskingFrameType = all or unknown, this object is
applicable.
- If maskingProtocolType = 'all', 'sna', 'netbios', dec or
'unknown', the maskingDestMacOrNet can be macAddress only!
- If maskingProtocolType = 'ip' the
maskingDestMacOrNet can be macAddress or netAddress or
appleAddress.
- If maskingProtocolType = 'ipx', the
maskingDestMacOrNet can be either macAddress or netAddress.
- If maskingProtocolType = 'apple', the
maskingDestMacOrNet can be either macAddress or appleAddress.
The variable maskingDestAddress and maskingDestActiveBits will
be treated as MAC, or NET address. "
::= { maskingEntry 14 }
maskingDestCondition OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If maskingFrameType = broadcast or multicast, this object
is NOT APPLICABLE.
If maskingFrameType = all or unknown, this object is
applicable.
Specifies the logical condition of the mask pattern:
true - Condition is valid if at the position specified by
maskingDestAddress (in conjunction with maskingDestActiveBits)
the packet contains data that matches the content of maskingDestAddress.
false - Condition is valid if at the position specified by
maskingDestAddress (in conjunction with maskingDestActiveBits)
the packet contains data that does not match the content of maskingDestAddress."
::= { maskingEntry 15 }
maskingLowLevelProt OBJECT-TYPE
SYNTAX INTEGER {
unknown (1), -- don't care
ipxRip (2), -- 0x51
ipxSap (3), -- 0x52
ipxSpx (4), -- 0x53
ipUdp (5), -- 0x54
ipTcp (6), -- 0x55
ipIcmp (7), -- 0x56
ipxNcp (8), -- 0x57
ipxWan (9), -- 0x58
ipxEco (10), -- 0x59
ipxErr (11), -- 0x5a
ipxPep (12) -- 0x5b
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field is set in conjunction with the maskingProtocolType variable.
This variable specifies the low level protocol.
The IPX socket entered in maskingDestAddress has priority
over the value of maskingLowLevelProt, when it is ipxRip,
ipxSap or ipxSpx, unless the entered IPX socket is don't
care."
::= { maskingEntry 16 }
maskingLowLevelProtCondition OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the logical condition of the mask pattern:
true - Condition is valid if at the position specified by
maskingLowLevelProt the packet contains data that matches
the content of maskingLowLevelProt.
false - Condition is valid if at the position specified by
maskingLowLevelProt the packet contains data that does not
match the content of maskingLowLevelProt."
::= { maskingEntry 17 }
maskingHighLevelProt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field is set in connection to the maskingProtocolType variable.
This variable specifies the high level protocols (application).
As for today it supports just IP protocol stack.
The object's value is a sum of the following instances values
(selected by user):
none (0), -- don't care
ftp (1),
ftpC (2),
telnet (4),
smtp (8),
tftp (16),
snmp (32),
snmpTrap (64),
ipRip (128),
www (256),
email (512),
dns (1024),
For Apple Protocol only:
rtmp (2048),
nbp (4096),
atp (8192),
aep (16384),
zip (32768),
adsp (65536),
pap (131072),
asp (262144)
Example: if ftp(1), snmp(32) and snmpTrap(64) instances
were selected, the value should be 97 (=1+32+64)."
::= { maskingEntry 18 }
maskingHighLevelProtCondition OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the logical condition of the mask pattern:
true - Condition is valid if at the position specified by
maskingHighLevelProt the packet contains data that matches
the content of maskingHighLevelProt.
false - Condition is valid if at the position specified by
maskingHighLevelProt the packet contains data that does not
match the content of maskingHighLevelProt."
::= { maskingEntry 19 }
maskingPortNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port number is the same as in high level protocol. It
specifies the dest. port in IP case or the dest. socket
in case of IPX & apple protocols.
IP - This object is applicable only if none (0) value was selected in
maskingHighLevelProt.
IPX - This object is applicable only if the socket
entered in maskingDestAddress is 'don't care'(00) AND
maskingLowLevelProt is NOT ipxRip or ipxSap.
Apple - This option is applicable only if the socket
entered in maskingDestAddress is 'don't care'(00)."
::= { maskingEntry 20 }
maskingPortNumCondition OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the logical condition of the mask pattern:
true - Condition is valid if at the position specified by
maskingPortNum the packet contains data that matches
the content of maskingPortNum.
false - Condition is valid if at the position specified by
maskingPortNum the packet contains data that does not
match the content of maskingPortNum.
This object is applicable only when maskingPortNum is applicable."
::= { maskingEntry 21 }
maskingOperation OBJECT-TYPE
SYNTAX INTEGER {
block (1),
forward (2),
route (3),
forward-route (4),
high-priority (5),
noOp (6),
delete (7),
smartMask (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of action to be taken if the frame meets the
conditions of the mask.
noOp = disabled (mask remains on list, but is not active)
delete = mask is removed from the list.
smartMask = the operation and destination of the mask will
be determined by the objects of the Smart Table
(old masking table: radBridgeMaskTable).
If maskingType is codConnect, the 'block' value is NOT
allowed.
If maskingType is codDisconnect, the 'forward' value is NOT
allowed."
::= { maskingEntry 22 }
maskingSrcPortNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The source port number.
For IP: No Condition.
For IPX: This object is applicable only if the socket entered in
maskingSourceAddress is don't care (00) and maskingLowLevelProt
is NOT ipxRip or ipxSap.
For Apple:This object is applicable only if the socket entered in
maskingSourceAddress is don't care (00). "
::= { maskingEntry 23 }
maskingSrcPortNumCondition OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The same as 'maskingPortNumCondition'.
Relates to source port."
::= { maskingEntry 24 }
radBridgePerformance OBJECT IDENTIFIER ::= {genBridge 7 }
-- The RAD Bridge current table contains statistics being
-- collected for the current 15 minute interval.
radBridgeCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The RAD Bridge Current table."
::= { radBridgePerformance 1 }
radBridgeCurrentEntry OBJECT-TYPE
SYNTAX RadBridgeCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the RAD Bridge Current table."
INDEX { radBridgeCurrentIndex }
::= { radBridgeCurrentTable 1 }
RadBridgeCurrentEntry ::=
SEQUENCE {
radBridgeCurrentIndex Integer32,
radBridgeCurrentIngressFilteringDiscardedFrames Gauge32,
radBridgeCurrentFrameTypeDiscardedFrames Gauge32,
radBridgeCurrentRxCorrectFrames Gauge32,
radBridgeCurrentRxCorrectBytes Gauge32,
radBridgeCurrentRxCorrectBytesHCOverflow Gauge32,
radBridgeCurrentRxBcastFrames Gauge32,
radBridgeCurrentRxMcastFrames Gauge32,
radBridgeCurrentTxCorrectFrames Gauge32,
radBridgeCurrentTxCorrectBytes Gauge32,
radBridgeCurrentTxCorrectBytesHCOverflow Gauge32,
radBridgeCurrentTxBcastFrames Gauge32,
radBridgeCurrentTxMcastFrames Gauge32,
radBridgeCurrentTxDropFrames Gauge32
}
radBridgeCurrentIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the Bridge interface or Bridge Port.
It may be ifIndex."
::= { radBridgeCurrentEntry 1 }
radBridgeCurrentIngressFilteringDiscardedFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Discarded
Frames upon Ingress Filtering, encountered by a Bridge
interface in the current 15 minute interval."
::= { radBridgeCurrentEntry 2 }
radBridgeCurrentFrameTypeDiscardedFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Discarded
Frames upon Frame Type and Tagging Mismatch, encountered
by a Bridge interface in the current 15 minute interval."
::= { radBridgeCurrentEntry 3 }
radBridgeCurrentRxCorrectFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Received Correct Frames,
encountered by a Bridge Port in the current 15 minute interval."
::= { radBridgeCurrentEntry 4 }
radBridgeCurrentRxCorrectBytes OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Received Correct Bytes,
encountered by a Bridge Port in the current 15 minute interval."
::= { radBridgeCurrentEntry 5 }
radBridgeCurrentRxCorrectBytesHCOverflow OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of times the associated
radBridgeCurrentRxCorrectBytes counter has overflowed."
::= { radBridgeCurrentEntry 6 }
radBridgeCurrentRxBcastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Received Broadcast Frames,
encountered by a Bridge Port in the current 15 minute interval."
::= { radBridgeCurrentEntry 7 }
radBridgeCurrentRxMcastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Received Multicast Frames,
encountered by a Bridge Port in the current 15 minute interval."
::= { radBridgeCurrentEntry 8 }
radBridgeCurrentTxCorrectFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Transmitted Correct Frames,
encountered by a Bridge Port in the current 15 minute interval."
::= { radBridgeCurrentEntry 9 }
radBridgeCurrentTxCorrectBytes OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Transmitted Correct Bytes,
encountered by a Bridge Port in the current 15 minute interval."
::= { radBridgeCurrentEntry 10 }
radBridgeCurrentTxCorrectBytesHCOverflow OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of times the associated
radBridgeCurrentTxCorrectBytes counter has overflowed."
::= { radBridgeCurrentEntry 11 }
radBridgeCurrentTxBcastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Transmitted Broadcast Frames,
encountered by a Bridge Port in the current 15 minute interval."
::= { radBridgeCurrentEntry 12 }
radBridgeCurrentTxMcastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Transmitted Multicast Frames,
encountered by a Bridge Port in the current 15 minute interval."
::= { radBridgeCurrentEntry 13 }
radBridgeCurrentTxDropFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Transmitted Dropped Frames,
encountered by a Bridge Port in the current 15 minute interval."
::= { radBridgeCurrentEntry 14 }
--Interval Table
-- The RAD Bridge Interval table contains statistics being
-- collected by each Interface over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
radBridgeIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The RAD Bridge Interval table."
::= { radBridgePerformance 2 }
radBridgeIntervalEntry OBJECT-TYPE
SYNTAX RadBridgeIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the RAD Bridge Interval table."
INDEX { radBridgeIntervalIndex, radBridgeIntervalNumber }
::= { radBridgeIntervalTable 1 }
RadBridgeIntervalEntry ::=
SEQUENCE {
radBridgeIntervalIndex Integer32,
radBridgeIntervalNumber Integer32,
radBridgeIntervalIngressFilteringDiscardedFrames Gauge32,
radBridgeIntervalFrameTypeDiscardedFrames Gauge32,
radBridgeIntervalRxCorrectFrames Gauge32,
radBridgeIntervalRxCorrectBytes Gauge32,
radBridgeIntervalRxCorrectBytesHCOverflow Gauge32,
radBridgeIntervalRxBcastFrames Gauge32,
radBridgeIntervalRxMcastFrames Gauge32,
radBridgeIntervalTxCorrectFrames Gauge32,
radBridgeIntervalTxCorrectBytes Gauge32,
radBridgeIntervalTxCorrectBytesHCOverflow Gauge32,
radBridgeIntervalTxBcastFrames Gauge32,
radBridgeIntervalTxMcastFrames Gauge32,
radBridgeIntervalTxDropFrames Gauge32
}
radBridgeIntervalIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the bridge interface or Bridge Port.
It may be ifIndex."
::= { radBridgeIntervalEntry 1 }
radBridgeIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals exist)."
::= { radBridgeIntervalEntry 2 }
radBridgeIntervalIngressFilteringDiscardedFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Discarded
Frames upon Ingress Filtering, encountered by a
Bridge interface in one of the previous 96, individual
15 minute, intervals."
::= { radBridgeIntervalEntry 3 }
radBridgeIntervalFrameTypeDiscardedFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Discarded
Frames upon Frame Type and Tagging Mismatch, encountered
by a Bridge interface in one of the previous 96, individual
15 minute, intervals."
::= { radBridgeIntervalEntry 4 }
radBridgeIntervalRxCorrectFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Received Correct Frames,
encountered by a Bridge Port in one of the previous 96,
individual 15 minute, intervals."
::= { radBridgeIntervalEntry 5 }
radBridgeIntervalRxCorrectBytes OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Received Correct Bytes,
encountered by a Bridge Port in one of the previous 96,
individual 15 minute, intervals."
::= { radBridgeIntervalEntry 6 }
radBridgeIntervalRxCorrectBytesHCOverflow OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of times the associated
radBridgeIntervalRxCorrectBytes counter has overflowed."
::= { radBridgeIntervalEntry 7 }
radBridgeIntervalRxBcastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Received Broadcast Frames,
encountered by a Bridge Port in one of the previous 96,
individual 15 minute, intervals."
::= { radBridgeIntervalEntry 8 }
radBridgeIntervalRxMcastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Received Multicast Frames,
encountered by a Bridge Port in one of the previous 96,
individual 15 minute, intervals."
::= { radBridgeIntervalEntry 9 }
radBridgeIntervalTxCorrectFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Transmitted Correct Frames,
encountered by a Bridge Port in one of the previous 96,
individual 15 minute, intervals."
::= { radBridgeIntervalEntry 10 }
radBridgeIntervalTxCorrectBytes OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Transmitted Correct Bytes,
encountered by a Bridge Port in one of the previous 96,
individual 15 minute, intervals."
::= { radBridgeIntervalEntry 11 }
radBridgeIntervalTxCorrectBytesHCOverflow OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of times the associated
radBridgeIntervalTxCorrectBytes counter has overflowed."
::= { radBridgeIntervalEntry 12 }
radBridgeIntervalTxBcastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Transmitted Broadcast Frames,
encountered by a Bridge Port in one of the previous 96,
individual 15 minute, intervals."
::= { radBridgeIntervalEntry 13 }
radBridgeIntervalTxMcastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Transmitted Multicast Frames,
encountered by a Bridge Port in one of the previous 96,
individual 15 minute, intervals."
::= { radBridgeIntervalEntry 14 }
radBridgeIntervalTxDropFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Transmitted Dropped Frames,
encountered by a Bridge Port in one of the previous 96,
individual 15 minute, intervals."
::= { radBridgeIntervalEntry 15 }
radBridgePortBaseVlan OBJECT IDENTIFIER ::= {genBridge 8 }
radBridgePortBaseVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgePortBaseVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing static configuration information for
each VLAN configured into the device by management.
All entries are permanent and will
be restored after the device is reset."
::= { radBridgePortBaseVlan 1 }
radBridgePortBaseVlanEntry OBJECT-TYPE
SYNTAX RadBridgePortBaseVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Static information for a VLAN configured into the
device by (local or network) management."
INDEX { radBridgePortBaseVlanCnfgIdx,radBridgePortBaseVlanIdx }
::= { radBridgePortBaseVlanTable 1 }
RadBridgePortBaseVlanEntry ::=
SEQUENCE {
radBridgePortBaseVlanCnfgIdx Integer32,
radBridgePortBaseVlanIdx Integer32,
radBridgePortBaseVlanName SnmpAdminString,
radBridgePortBaseVlanEgressPorts PortList,
radBridgePortBaseVlanVirtualGroups PortList,
radBridgePortBaseVlanRowStatus RowStatus,
radBridgePortBaseVlanMng INTEGER
}
radBridgePortBaseVlanCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Idx of the Agent Cnfg the following
objects refer.
255=Temporary Cnfg (when relevant,
Set is done only to this configuration).
For Agents that support only one configuration,
this object will be constant=1. "
::= { radBridgePortBaseVlanEntry 1 }
radBridgePortBaseVlanIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the port based VLAN."
::= { radBridgePortBaseVlanEntry 2 }
radBridgePortBaseVlanName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An administratively assigned string, which may be used
to identify the the port based VLAN."
::= { radBridgePortBaseVlanEntry 3 }
radBridgePortBaseVlanEgressPorts OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The set of ports which are permanently assigned to the
egress list for this port based VLAN by management.
The default value of this object is a string of zeros."
::= { radBridgePortBaseVlanEntry 4 }
radBridgePortBaseVlanVirtualGroups OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The set of Virtual Groups which are permanently assigned to
this port based VLAN by management.
(read Virtual Group instead of port in PortList Textual Convention)
The default value of this object is a string of zeros."
::= { radBridgePortBaseVlanEntry 5 }
radBridgePortBaseVlanRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enable user to
create/delete entries in this table."
::= { radBridgePortBaseVlanEntry 6 }
radBridgePortBaseVlanMng OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object allows user to enable/disable
management traffic on this VLAN.
disable - only non-management data is allowed.
enable - mixture of management traffic 0with other
types of data is allowed."
::= { radBridgePortBaseVlanEntry 7 }
-- The Bridge's Ports-VLANs Memebership Table
radBridgePortVlanMemberTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgePortVlanMemberEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Bridge Ports-VLAN Membership table.
This table enables the user to assign:
- Several VLANs to a Port.
- Several Ports to a VLAN."
::= { radBridgePortBaseVlan 2 }
radBridgePortVlanMemberEntry OBJECT-TYPE
SYNTAX RadBridgePortVlanMemberEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Bridge Ports-VLANs Memebership table."
INDEX { radBridgePortVlanMemberBridgeIdx,
radBridgePortVlanMemberPortIdx,
radBridgePortVlanMemberVlanId }
::= { radBridgePortVlanMemberTable 1 }
RadBridgePortVlanMemberEntry ::=
SEQUENCE {
radBridgePortVlanMemberBridgeIdx Integer32,
radBridgePortVlanMemberPortIdx Integer32,
radBridgePortVlanMemberVlanId Integer32,
radBridgePortVlanMemberRowStatus RowStatus
}
radBridgePortVlanMemberBridgeIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Bridge Index."
::= { radBridgePortVlanMemberEntry 1 }
radBridgePortVlanMemberPortIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Bridge's Port Index.
For some cases, it can be used as the Port ofIndex."
::= { radBridgePortVlanMemberEntry 2 }
radBridgePortVlanMemberVlanId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the VLAN ID."
::= { radBridgePortVlanMemberEntry 3 }
radBridgePortVlanMemberRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables the user to
create/delete entries in this table."
::= { radBridgePortVlanMemberEntry 4 }
radBridgeGenCnfg OBJECT IDENTIFIER ::= {genBridge 9 }
radBridgeGenFlowTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeGenFlowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing static configuration information for
Bridge configured into the device by (local or
network) management. All entries are permanent and will
be restored after the device is reset."
::= { radBridgeGenCnfg 1 }
radBridgeGenFlowEntry OBJECT-TYPE
SYNTAX RadBridgeGenFlowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Static information for a Bridge configured into the
device by management."
INDEX { radBridgeGenFlowCnfgIdx,radBridgeGenFlowIdx }
::= { radBridgeGenFlowTable 1 }
RadBridgeGenFlowEntry ::=
SEQUENCE
{
radBridgeGenFlowCnfgIdx Integer32,
radBridgeGenFlowIdx Integer32,
radBridgeGenFlowRowStatus RowStatus,
radBridgeGenFlowFloodOrBcastMaxRate Integer32,
radBridgeGenFlowQosMode INTEGER,
radBridgeGenFlowSchedulingMode INTEGER,
radBridgeGenFlowBasicClassification INTEGER,
radBridgeGenFlowMulticastTrafficClass Integer32,
radBridgeGenFlowBroadcastTrafficClass Integer32,
radBridgeGenFlowUnkownUnicastTrafficClass Integer32
}
radBridgeGenFlowCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Idx of the
Agent Cnfg the following objects refer.
255=Temporary Cnfg (when relevant Set is done
only to this configuration).
For Agents that support only one configuration,
this object will be constant=1.
This object can be used to carry additional indexing
(e.g port index) when needed."
::= { radBridgeGenFlowEntry 1 }
radBridgeGenFlowIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For Agent having more than one bridge,
this index may be used as bridge index "
::= { radBridgeGenFlowEntry 2 }
radBridgeGenFlowRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enable user to
create/delete entries in this table."
::= { radBridgeGenFlowEntry 3 }
radBridgeGenFlowFloodOrBcastMaxRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls maximum Flooding or Broadcast Rate:
Max number of multicast along with unknown
or flooded unicast frames allowed to enter
any port.
The number can be presented either as percentage of bandwidth, or bandwidth in Kbps.
Once the limit is exceeded, any multicast or flooded
frame entering from the port is discarded
For RIC-155, and FCD-155 valid values are 3% , 6%, 12%
and 100% = No Limit"
::= { radBridgeGenFlowEntry 4 }
radBridgeGenFlowQosMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
vlanTag (2), -- 802.1p
dscp (3),
dscpAndVlanTag (4),
vlanTagAndDscp (5),
none (6),
tos (7),
perPort (8),
ipPrecedence (9),
dsField (10),
vlanTagAndTos (11),
tosAndVlanTag (12),
vlanTagAndIpPrecedence(13),
ipPrecedenceAndVlanTag(14),
vlanTagAndDsField (15),
dsFieldAndVlanTag (16)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls Quality of Service mode.
User may select which field(s)
(in case of fields - which one has precedence)
will affect prioritization of data between egress queues."
::= { radBridgeGenFlowEntry 5 }
radBridgeGenFlowSchedulingMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
wfq (2), -- Weighted Fair Queuing
sp (3), -- Strict Priority
atmCos (4) -- ATM Class of Service
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls which scheduling mode is used:
Weighted Fair Queuing (WFQ) scheme,
Strict Priority (SP)
or ATM CoS"
::= { radBridgeGenFlowEntry 6 }
radBridgeGenFlowBasicClassification OBJECT-TYPE
SYNTAX INTEGER
{
none (2),
port (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object defines whether Classification based on Port should be
taken into account (either as default, or in addition to other
classifications)."
::= { radBridgeGenFlowEntry 7 }
radBridgeGenFlowMulticastTrafficClass OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Traffic Class the received Multicast frame is mapped to."
::= { radBridgeGenFlowEntry 8 }
radBridgeGenFlowBroadcastTrafficClass OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Traffic Class the received Broadcast frame is mapped to."
::= { radBridgeGenFlowEntry 9 }
radBridgeGenFlowUnkownUnicastTrafficClass OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Traffic Class the received
Unkonwn Unicast frame is mapped to."
::= { radBridgeGenFlowEntry 10 }
radBridgeDot1qVlanStaticTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeDot1qVlanStaticEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing static configuration information for
each VLAN configured into the device by (local or
network) management. All entries are permanent and will
be restored after the device is reset."
::= { radBridgeGenCnfg 2 }
radBridgeDot1qVlanStaticEntry OBJECT-TYPE
SYNTAX RadBridgeDot1qVlanStaticEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Static information for a VLAN configured into the
device by (local or network) management."
AUGMENTS { dot1qVlanStaticEntry }
::= { radBridgeDot1qVlanStaticTable 1 }
RadBridgeDot1qVlanStaticEntry ::=
SEQUENCE {
radBridgeDot1qVlanTaggedPorts
PortList,
radBridgeDot1qVlanUnmodifiedPorts
PortList,
radBridgeDot1qVlanSplitHorizon
INTEGER
}
radBridgeDot1qVlanTaggedPorts OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The set of ports which should transmit egress packets
for this VLAN as tagged."
::= { radBridgeDot1qVlanStaticEntry 1 }
radBridgeDot1qVlanUnmodifiedPorts OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The set of ports which should transmit egress packets
for this VLAN as unmodified."
::= { radBridgeDot1qVlanStaticEntry 2 }
radBridgeDot1qVlanSplitHorizon OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"When 'enable (3)', packets having this VLAN will
not be switched back to other bridge ports which are
members of this VLAN."
::= { radBridgeDot1qVlanStaticEntry 3 }
radBridgeStatus OBJECT IDENTIFIER ::= {genBridge 10 }
radBridgeInvBasePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeInvBasePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An inversed table to dot1dBasePortTable
from RFC1493 with reduced information.
This table index is known to the NMS and
this way the needed information can be received
by just one Get command, instead of searching
the entire dot1dBasePortTable (where it is an
attribute). "
::= { radBridgeStatus 1 }
radBridgeInvBasePortEntry OBJECT-TYPE
SYNTAX RadBridgeInvBasePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The bridge port number for each bridge port
interface index."
INDEX { radBridgeInvBasePortIfIndex }
::= { radBridgeInvBasePortTable 1 }
RadBridgeInvBasePortEntry ::=
SEQUENCE {
radBridgeInvBasePortIfIndex Integer32,
radBridgeInvBasePort Integer32
}
radBridgeInvBasePortIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the instance of the ifIndex object,
defined in MIB-II, for the interface corresponding
to this Bridge port."
::= { radBridgeInvBasePortEntry 1 }
radBridgeInvBasePort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Bridge port number."
::= { radBridgeInvBasePortEntry 2 }
--Spanning Tree Protocol (STP)
radBridgeStp OBJECT IDENTIFIER ::= {genBridge 11 }
--Configuration Table
radBridgeStpCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeStpCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"STP Configuration table. STP=Spanning Tree Protocol.
It includes STP configurable parameters that in BRIDGE-MIB
are scalars, while we need them per card/bridge/interface
and per different configurations."
::= { radBridgeStp 1 }
radBridgeStpCnfgEntry OBJECT-TYPE
SYNTAX RadBridgeStpCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the radBridgeStpCnfgTable."
INDEX {radBridgeStpCnfgIdx1, radBridgeStpCnfgIdx2}
::= { radBridgeStpCnfgTable 1 }
RadBridgeStpCnfgEntry ::=
SEQUENCE {
radBridgeStpCnfgIdx1 Integer32,
radBridgeStpCnfgIdx2 Integer32,
radBridgeStpCnfgForwardDelay Timeout,
radBridgeStpCnfgMaxAge Timeout,
radBridgeStpCnfgHelloTime Timeout,
radBridgeStpCnfgPriority Integer32,
radBridgeStpCnfgStpVersion INTEGER
}
radBridgeStpCnfgIdx1 OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Index of the Agent Configuration
the following objects refer to.
For Agents that support more than one configuration:
255=Temporary Cnfg ; Set can be done only to this configuration.
For Agents that support only one configuration, this object will be
constant=1."
::= { radBridgeStpCnfgEntry 1 }
radBridgeStpCnfgIdx2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For Agents having the table objects per Card/Bridge/Interface
this will be the index of the Card/Bridge/Interface used."
::= { radBridgeStpCnfgEntry 2 }
radBridgeStpCnfgForwardDelay OBJECT-TYPE
SYNTAX Timeout (400..3000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value that the bridge of radBridgeStpCnfgIdx2 uses for
Forward Delay when this bridge is acting as the root. Note that
the range for this parameter is related to the value of
radBridgeStpCnfgMaxAge (according to 802.1D-1990 for the similar
scalars of BRIDGE-MIB). The granularity of this timer is specified
by 802.1D-1990 to be 1 second.
An agent may return a badValue error if a set is attempted to a value
which is not a whole number of seconds."
::= { radBridgeStpCnfgEntry 3 }
radBridgeStpCnfgMaxAge OBJECT-TYPE
SYNTAX Timeout (600..4000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value that the bridge of radBridgeStpCnfgIdx2 uses for
MaxAge when this bridge is acting as the root. Note that
the range for this parameter is related to the value of
radBridgeStpCnfgHelloTime (according to 802.1D-1990 for the similar
scalars of BRIDGE-MIB). The granularity of this timer is specified
by 802.1D-1990 to be 1 second.
An agent may return a badValue error if a set is attempted to a value
which is not a whole number of seconds."
::= { radBridgeStpCnfgEntry 4 }
radBridgeStpCnfgHelloTime OBJECT-TYPE
SYNTAX Timeout (100..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value that the bridge of radBridgeStpCnfgIdx2 uses for
Hello Time when this bridge is acting as the root. The granularity
of this timer is specified by 802.1D-1990 to be 1 second. An agent
may return a badValue error if a set is attempted to a value
which is not a whole number of seconds."
::= { radBridgeStpCnfgEntry 5 }
radBridgeStpCnfgPriority OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the write-able portion of the Bridge ID, i.e., the first
two octets of the (8 octet long) Bridge ID, per radBridgeStpCnfgIdx2
instance."
::= { radBridgeStpCnfgEntry 6 }
radBridgeStpCnfgStpVersion OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
stp (2),
rstp (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines the STP version used:
stp - usual Spanning Tree Protocol.
rstp - Rapid Spanning Tree Protocol."
::= { radBridgeStpCnfgEntry 7 }
--Status Table
radBridgeStpStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeStpStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"STP Status table. STP=Spanning Tree Protocol.
It includes STP status parameters that in BRIDGE-MIB
are scalars, while we need them per card/bridge/interface.
For devices that have several configurations, this table is for Status
of the Active configuration."
::= { radBridgeStp 2 }
radBridgeStpStatEntry OBJECT-TYPE
SYNTAX RadBridgeStpStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the radBridgeStpStatTable."
INDEX {radBridgeStpStatIdx}
::= { radBridgeStpStatTable 1 }
RadBridgeStpStatEntry ::=
SEQUENCE {
radBridgeStpStatIdx Integer32,
radBridgeStpStatForwardDelay Timeout,
radBridgeStpStatMaxAge Timeout,
radBridgeStpStatHelloTime Timeout,
radBridgeStpStatDesignatedRoot BridgeId,
radBridgeStpStatRootCost Integer32
}
radBridgeStpStatIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For Agents having the table objects per Card/Bridge/Interface
this will be the index of the Card/Bridge/Interface used."
::= { radBridgeStpStatEntry 1 }
radBridgeStpStatForwardDelay OBJECT-TYPE
SYNTAX Timeout
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This time value, measured in units of hundredths of a second,
controls how fast a port changes its spanning state when moving
towards the Forwarding state. The value determines how long the port
stays in each of the Listening and Learning states, which precede
the Forwarding state. This value is also used, when a topology
change has been detected and is underway, to age all dynamic
entries in the Forwarding Database. [Note that this value is
the one that this bridge is currently using, in contrast to
radBridgeStpCnfgForwardDelay which is the value that this bridge
would start using if/when this bridge were to become the root.]"
::= { radBridgeStpStatEntry 2 }
radBridgeStpStatMaxAge OBJECT-TYPE
SYNTAX Timeout
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum age of Spanning Tree Protocol information learned
from the network on any port before it is discarded, in units
of hundredths of a second. This is the actual value that this
bridge is currently using."
::= { radBridgeStpStatEntry 3 }
radBridgeStpStatHelloTime OBJECT-TYPE
SYNTAX Timeout
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of time between the transmission of Configuration
bridge PDUs by this node on any port when it is the root of
the spanning tree or trying to become so, in units of hundredths
of a second. This is the actual value that this bridge is
currently using."
::= { radBridgeStpStatEntry 4 }
radBridgeStpStatDesignatedRoot OBJECT-TYPE
SYNTAX BridgeId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The bridge identifier of the root of the spanning tree as determined
by the Spanning Tree Protocol as executed by this node. This value
is used as the Root Identifier parameter in all Configuration
Bridge PDUs originated by this node."
::= { radBridgeStpStatEntry 5 }
radBridgeStpStatRootCost OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The cost of the path to the root as seen from this bridge."
::= { radBridgeStpStatEntry 6 }
radBridgeForwardingMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
transparent (2),
filter (3),
filterTagged (4),
transparentTagged (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines the Bridge Forwarding Mode:
transparent - Forward all frames received (not dependent on VLAN).
filter - Filter frames received according to MAC Address.
filterTagged = Filter frames received according to VLAN.
transparentTagged = VLAN aware + Transparent."
::= {genBridge 12 }
radBridgePort OBJECT IDENTIFIER ::= { genBridge 13 }
radBridgePortCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgePortCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Bridge Port Configuration Table."
::= { radBridgePort 1 }
radBridgePortCnfgEntry OBJECT-TYPE
SYNTAX RadBridgePortCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
INDEX { radBridgePortCnfgIdx, radBridgePortCnfgPrtIdx }
::= { radBridgePortCnfgTable 1 }
RadBridgePortCnfgEntry ::=
SEQUENCE {
radBridgePortCnfgIdx Integer32,
radBridgePortCnfgPrtIdx Integer32,
radBridgePortCnfgMaxMacAddr Integer32,
radBridgePortCnfgMngFlow INTEGER,
radBridgePortCnfgMcastMode INTEGER,
radBridgePortCnfgDefaultVpi Integer32,
radBridgePortCnfgDefaultVci Integer32,
radBridgePortCnfgStatVlanId Integer32,
radBridgePortCnfgIngressMtu Integer32,
radBridgePortCnfgEgressMtu Integer32,
radBridgePortCnfgDot1x INTEGER, -- Not in use. Moved to ethIftable
radBridgePortCnfgMappingProfile Integer32
}
radBridgePortCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The first index of the table.
It can serve for Configuration index, Bridge index or other."
::= { radBridgePortCnfgEntry 1 }
radBridgePortCnfgPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Bridge Port index."
::= { radBridgePortCnfgEntry 2 }
radBridgePortCnfgMaxMacAddr OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the maximum number of total MAC Addresses
(static and learned) supported by this Bridge Port."
::= { radBridgePortCnfgEntry 3 }
radBridgePortCnfgMngFlow OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether this Bridge Port
is dedicated for management flow."
::= { radBridgePortCnfgEntry 4 }
radBridgePortCnfgMcastMode OBJECT-TYPE
SYNTAX INTEGER {
flooding (1),
forwarding (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates this Bridge Port's Multicast Mode:
flooding (1) - flood multicast MAC addresses
forwarding (2) - forward multicast MAC addresses to the subnet indicated."
::= { radBridgePortCnfgEntry 5 }
radBridgePortCnfgDefaultVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the VPI of this Bridge Port's Default VCL.
An incoming frame with priority that is not assigned to any VCL
will be transferred to the Default VCL."
::= { radBridgePortCnfgEntry 6 }
radBridgePortCnfgDefaultVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the VCI of this Bridge Port's Default VCL.
An incoming frame with priority that is not assigned to any VCL
will be transferred to the Default VCL."
::= { radBridgePortCnfgEntry 7 }
radBridgePortCnfgStatVlanId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the selected VlanId of the bridge port
on which statistics are being collected.
0=no Statistics collected for VLAN on this bridge port."
::= { radBridgePortCnfgEntry 8 }
radBridgePortCnfgIngressMtu OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The size of the largest packet which can be received
on the interface, specified in octets."
::= { radBridgePortCnfgEntry 9 }
radBridgePortCnfgEgressMtu OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The size of the largest packet which can be sent
on the interface, specified in octets."
::= { radBridgePortCnfgEntry 10 }
radBridgePortCnfgDot1x OBJECT-TYPE
SYNTAX INTEGER
{
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This feature is currently supported via the variable ethIfTable.ethDot1xEnable.
Determnines if the Port-Based Network Access Protocol
(IEEE-802.1x)is enabled for the bridge Port."
::= { radBridgePortCnfgEntry 11 }
radBridgePortCnfgMappingProfile OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute defines the Queue Mapping Profile ID(cosProfileTable) assigned
to this Bridge Port."
::= { radBridgePortCnfgEntry 12 }
radDot1qPortVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadDot1qPortVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing control and status
information for VLAN configuration per port."
::= { radBridgeGenCnfg 3 }
radDot1qPortVlanEntry OBJECT-TYPE
SYNTAX RadDot1qPortVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information controlling VLAN configuration for a port.
This is indexed by dot1dBasePort."
AUGMENTS { dot1dBasePortEntry }
::= { radDot1qPortVlanTable 1 }
RadDot1qPortVlanEntry ::=
SEQUENCE {
radDot1qPortStacking
INTEGER,
radDot1qPortCopyOriginVlanPriority
INTEGER,
radDot1qPortDefaultVlanPriority
Integer32,
radDot1qPortTagStripping
INTEGER,
radDot1qPortEgressTagHandling
INTEGER,
radDot1qPortIngressTagHandling
INTEGER,
radDot1qPortReplaceVlanPriority
INTEGER,
radDot1qPortVlanEthType
Unsigned32,
radDot1qPortVlanCnodeLevel1Agent
INTEGER
}
radDot1qPortStacking OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
unmodify (2),
tag (3),
stack (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the port stacking operation:
unmodify (2) = Do not add Tag.
tag (3) = Add Tag to Untagged Frames.
stack (4) = Add Tag to all Frames."
::= { radDot1qPortVlanEntry 1 }
radDot1qPortCopyOriginVlanPriority OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether use the original VLAN Priority of the frame,
as the priority of the VLAN added by this port."
::= { radDot1qPortVlanEntry 2 }
radDot1qPortDefaultVlanPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default VLAN Frame priority of the VLAN added by this port."
::= { radDot1qPortVlanEntry 3 }
radDot1qPortTagStripping OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether remove a tag from the frame on this port,
frame with double tag will remain with one tag and frame with
one tag will remain untagged."
::= { radDot1qPortVlanEntry 4 }
radDot1qPortEgressTagHandling OBJECT-TYPE
SYNTAX INTEGER
{
none (2),
stacking (3),
stripping (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates how is the Egress VLAN Tag processed.
It is mainly for use with Double Tagging."
::= { radDot1qPortVlanEntry 5 }
radDot1qPortIngressTagHandling OBJECT-TYPE
SYNTAX INTEGER
{
none (2),
stacking (3),
stripping (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates how is the Ingress VLAN Tag processed.
It is mainly for use with Double Tagging."
::= { radDot1qPortVlanEntry 6 }
radDot1qPortReplaceVlanPriority OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether for each received tagged frame on this Bridge Port -
VLAN Priority will be replaced by another Priority.
no(2) = no repacement
yes(3) = VLAN Priority will be replaced
For Egate-100:
When value is 'yes', the original Priority is replaced by the Default Priority."
::= { radDot1qPortVlanEntry 7 }
radDot1qPortVlanEthType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Ethernet Type.
For some devices, it is applicable only when radDot1qPortStacking = stack."
::= { radDot1qPortVlanEntry 8 }
radDot1qPortVlanCnodeLevel1Agent OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify if a Level 1 cNode agent is enabled or not for the bridge port."
::= { radDot1qPortVlanEntry 9 }
radBridgeGenCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeGenCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing Bridge configuration parameters."
::= { radBridgeGenCnfg 4 }
radBridgeGenCfgEntry OBJECT-TYPE
SYNTAX RadBridgeGenCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes an entry in the radBridgeGenCfgTable."
INDEX { radBridgeGenCfgIdx, radBridgeGenCfgIdx2 }
::= { radBridgeGenCfgTable 1 }
RadBridgeGenCfgEntry ::=
SEQUENCE
{
radBridgeGenCfgIdx Integer32,
radBridgeGenCfgIdx2 Integer32,
radBridgeGenCfgBridgeAction INTEGER,
radBridgeAgingTimeSec INTEGER,
radBridgeMngVlanId Unsigned32,
radBridgeLoopDetectVlanId Unsigned32,
radBridgeSplitHorizon INTEGER,
radBridgeEthType Unsigned32
}
radBridgeGenCfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Idx of the
Agent Cnfg the following objects refer.
255=Temporary Cnfg.
For Agents that support only one Configuration,
this object will be constant=1. "
::= { radBridgeGenCfgEntry 1 }
radBridgeGenCfgIdx2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For Agents having more than one bridge,
this index may be used as bridge index "
::= { radBridgeGenCfgEntry 2 }
radBridgeGenCfgBridgeAction OBJECT-TYPE
SYNTAX INTEGER {
deleteLanTab(7),
noOp(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable enables the operator to perform one of the
specified actions on the tables maintained by the Bridge.
After performing the action, Agent will automatically
Set the value of this variable to noOp(255)."
::= { radBridgeGenCfgEntry 3 }
radBridgeAgingTimeSec OBJECT-TYPE
SYNTAX INTEGER (10..1000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable duplicates scalar object
dot1dTpAgingTimeThe of BRIDGE-MIB with configuration index
and Bridge index.
It defines the timeout period in seconds for aging out
dynamically learned forwarding information.
802.1D-1990 recommends a default of 300 seconds."
REFERENCE
"IEEE 802.1D-1990: Section 6.7.1.1.3"
::= { radBridgeGenCfgEntry 4 }
radBridgeMngVlanId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates the VLAN ID
used for remote management traffic.
0 = Not Applicable."
::= { radBridgeGenCfgEntry 5 }
radBridgeLoopDetectVlanId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates the VLAN ID used for Loop Detection packets.
Valid values:
1 - 4095: VLAN ID
0 - Means that the Loop Detection is Disabled."
::= { radBridgeGenCfgEntry 6 }
radBridgeSplitHorizon OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
disable (2),
enabled (3),
vlanBased (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configure 'split horizon' switching between bridge Ports.
- disable - normal (VLAN aware) bridge behavior.
- enable - all packets, regardless their VLAN, coming from user side
are blocked from being switched back to other user side bridge ports.
- vlanBased - split horizon behavior is applicable only for specific VLANs,
according to radBridgeDot1qVlanSplitHorizon."
::= { radBridgeGenCfgEntry 7 }
radBridgeEthType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Value of Ethertype field in Ethernet frame.
This field indicates which protocol is being transported
in an ethernet frame."
::= { radBridgeGenCfgEntry 8 }
radBridgeAgingTime OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
infinite(2),
finite (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable defines whether the Aging Time will be finite or infinite.
When selecting the finite (3) value, the exact time will be determined
by another variable of the standard MIB (ex. 1493.dot1dTpAgingTime).
or by radBridgeAgingTime below."
::= { radBridgeGenCnfg 5 }
radBridgeMngFlow OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable defines whether the Management Flow is passed
through the bridge (enable) or not (disable)."
::= { radBridgeGenCnfg 6 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\trim.txt
--
--Title: TrimBridge MIB
--Version: 3.0
--Last revision: 9.10.94
--By: Debby Koren & Orly Nicklass
--File: trim.txt
-- Objects in this section are arranged into groups:
-- trimInterface - Interface table and RS232 interface parameters
-- trimBackup - Backup feature, Dial-up parameters.
-- trimTR - Token Ring interface management
-- trimTrapInfo - parameters that provide information on traps sent
--Comments: The Trimbridge-16 agent also supports the following Public MIBs:
-- MIB-II (RFC1213)
-- dot5 ( RFC1231-MIB, updated by RFC1239 ) except for the optional Timers-table
-- bridge (RFC 1493)
--Comments: The Trimbridge-10 agent also supports the following Public MIBs:
-- MIB-II (RFC1213)
-- bridge (RFC 1493)
-- the trimInterface group defines the Trimbridge interface table and parameters for
-- RS232 interface
trim OBJECT IDENTIFIER ::= {radBridges 3 }
trimInterface OBJECT IDENTIFIER ::= { trim 1 }
trimIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrimIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RAD-specific interface table. "
::= { trimInterface 1 }
trimIfEntry OBJECT-TYPE
SYNTAX TrimIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table trimIfTable."
INDEX { trimIfIndex }
::= { trimIfTable 1 }
TrimIfEntry ::= SEQUENCE {
trimIfIndex
Integer32,
trimIfBoardNum
Integer32,
trimIfNetAddress
IpAddress,
trimIfStatus
INTEGER,
trimIfClockType
INTEGER,
trimIfBaudRate
Integer32,
trimIfCost
Integer32,
trimIfCompression
INTEGER,
trimIfCompressionStatus
INTEGER,
trimIfCompressionRate
Integer32,
trimIfLATCompression
INTEGER,
trimIfCompressionType
INTEGER,
trimIfFilterMode
INTEGER,
trimIfConType
INTEGER,
trimIfRemAddress
DisplayString,
trimIfLocSubAddress
DisplayString,
trimIfRemSubAddress
DisplayString,
trimIfCLIVerification
INTEGER
}
trimIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index to the Trimbridge Interface Table. The interface defined by a
particular value of this index is the same interface as
identified by the same value of ifIndex (MIB II)."
::= { trimIfEntry 1 }
trimIfBoardNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reserved for possible future use. Not currently applicable to Trimbridge."
::= { trimIfEntry 2 }
trimIfNetAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address of the interface defined by the particular value of
trimIfIndex."
::= { trimIfEntry 3 }
trimIfStatus OBJECT-TYPE
SYNTAX INTEGER {
ok (1),
okSingleBrg(2),
okMultiBrg(3),
connctFault(4),
rxFault(5),
txFault(6),
channelLoopback(7),
rxClockFault(8),
t1Alarm(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of the interface. Some of these status values are not applicable to Trimbridge."
::= { trimIfEntry 4 }
trimIfClockType OBJECT-TYPE
SYNTAX INTEGER {
external(1),
internal(2),
t1(3),
g703(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"trimIfClockType defines the type of clock each interface
uses: internal or external."
::= { trimIfEntry 5 }
trimIfBaudRate OBJECT-TYPE -- Level II routing
SYNTAX Integer32 -- word
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Defines the baud rate in use by the interface. The valid
rates are determined by the type of the media for which this
baud rate is defined."
::= { trimIfEntry 6 }
trimIfCost OBJECT-TYPE -- Level II routing
SYNTAX Integer32 -- word
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is inapplicable to Trimbridge."
::= { trimIfEntry 7 }
trimIfCompression OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines whether data compression is enabled or disabled for the
interface."
::= { trimIfEntry 8 }
trimIfCompressionStatus OBJECT-TYPE
SYNTAX INTEGER {
not-inserted(1),
active(2),
not-active(3),
disable(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defines the status of the compression component:
not-inserted - compression component is not in the device
active - compression is enabled and operates correctly
not-active - compression is enables but does not operate.
The reason may be that there is no
compression component on the device connected
to this interface.
disabled - compression was disabled by management, using
variable trimCompression."
::= { trimIfEntry 9 }
trimIfCompressionRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of compression. This variable applies only
if trimCompressionStatus is active."
::= { trimIfEntry 10 }
trimIfLATCompression OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable the LAT Compression."
::= { trimIfEntry 11 }
trimIfCompressionType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
lowSpeed(2),
highSpeed(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates the type of compression option available in
the device.
`None(1) - indicates that there is no compression option in the device
lowSpeed(2) - indicates a compression option which is operational up
to line speed sof 64 kbps.
highSpeed(3) - indicates a compression option which is operational up
to line speeds of 2 Mbps."
::= { trimIfEntry 12 }
trimIfFilterMode OBJECT-TYPE
SYNTAX INTEGER {
destinationOnly(1),
sourceAndDestination(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the type of filtering in the device. "
::= { trimIfEntry 13 }
trimIfConType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
none(2),
x21Old(3),
x21(4),
v35Old(5),
v35(6),
rs530Old(7),
rs530(8),
rs232Old(9),
rs232(10),
spsV35(11),
spsRS530(12),
spsRS232(13),
spsX21(14),
isdn(15)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates the connector type of an interface. "
::= { trimIfEntry 14 }
trimIfRemAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..17))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" "
::= { trimIfEntry 15 }
trimIfLocSubAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Space is not valid. If the string includes a space,
the whole entry is considered not valid."
::= { trimIfEntry 16 }
trimIfRemSubAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Space is not valid. If the string includes a space,
the whole entry is considered not valid."
::= { trimIfEntry 17 }
trimIfCLIVerification OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Disables verification of Control Line Identification (CLI)"
::= { trimIfEntry 18 }
-- The variables in this group define the RS232 management interface
trimRS232Conf OBJECT IDENTIFIER ::= { trimInterface 2 }
trimBaudRate OBJECT-TYPE
SYNTAX INTEGER {
br300(1),
br1200(2),
br2400(5),
br4800(7),
br9600(9),
br19200(10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the baud rate used by the RS232 management interface. The
default selection is 1200 bits/second."
::= { trimRS232Conf 1 }
trimParity OBJECT-TYPE
SYNTAX INTEGER {
noParity(1),
oddParity(2),
evenParity(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines whether the parity bit will be used and determines
its type."
::= { trimRS232Conf 2 }
trimStopBit OBJECT-TYPE
SYNTAX INTEGER {
oneStopBit(1),
twoStopBit(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the number of stop bits appended to the end of
each data word."
::= { trimRS232Conf 3 }
trimThresholdRep OBJECT IDENTIFIER ::= { trimInterface 3}
trimIfThresholdRepTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrimIfThresholdRepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" ....."
::= {trimThresholdRep 1}
trimIfThresholdRepEntry OBJECT-TYPE
SYNTAX TrimIfThresholdRepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table trimIfThresholdRepTable."
INDEX { trimIfThreRepId,trimIfThreRepCounterId }
::= { trimIfThresholdRepTable 1}
TrimIfThresholdRepEntry ::= SEQUENCE {
trimIfThreRepId
Integer32,
trimIfThreRepCounterId
INTEGER,
trimThresholdValue
Integer32,
trimIfThreRepSampleRate
Integer32,
trimIfThreRepTrapRate
Integer32
}
trimIfThreRepId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Interface number serves as an index to the Threshold Reoprt Table."
::= { trimIfThresholdRepEntry 1 }
trimIfThreRepCounterId OBJECT-TYPE
SYNTAX INTEGER{
vot(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Counter ID serves as an index to the Threshold Reoprt Table, and identify the counter for which
to pot the threshold."
::= { trimIfThresholdRepEntry 2 }
trimThresholdValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Threshold value , this is the maximum rate of counter increments before the element issue trap."
::= { trimIfThresholdRepEntry 3 }
trimIfThreRepSampleRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The network object will sample the counter atthis interval. When this parameter
is set to 0, the treshold comparison is disable."
-- DEFVAL { 10 }
::= { trimIfThresholdRepEntry 4}
trimIfThreRepTrapRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The network object will issue a trap according to this interval. Note that the trape
interval nust be equal or larger then trimIfThreRepSampleRate."
-- DEFVAL { 30 }
::= { trimIfThresholdRepEntry 5}
-- trimBackup group defines the parameters for the backup feature
trimBackup OBJECT IDENTIFIER ::= { trim 2 }
trimBackupState OBJECT-TYPE
SYNTAX INTEGER {
main(1),
backup(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If main - the bridge is connected via the main physical link.
If backup - the automatic backup feature was enabled
and the bridge is connected via the backup physical link."
::= { trimBackup 1 }
trimDialUpStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter controls the operation of dial-up backup function.
If status is disable(2), dial-up backup will not be initiated when the
main link fails or exceeds the specified error limit.
If status is enable(1), the dial-up backup will be initiated if the main
link fails or if the error rate on the main link exceeds the limit specified
by variable trimDialUp ErrorThreshold."
::= { trimBackup 2 }
trimBackLinkType OBJECT-TYPE
SYNTAX INTEGER {
dialUp(1),
leased (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable specifies the type of the backup link. If the type is leased(2),
Trimbridge will reroute traffic to the backup link, when main link fails.
If the value is dialUp(1), then the backup dial-up procedure is initiated
when the main link fails."
::= { trimBackup 3 }
trimDialUpMode OBJECT-TYPE
SYNTAX INTEGER {
originate(1),
answer(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If the mode is originate(1), Trimbridge initiates the backup procedure when the
main link fails. if the mode is answer(2), it expects that the bridge on the
other end of the link will initiate the backup procedure. Note that only one
bridge in a pair should be set to mode originate(1). "
::= { trimBackup 4 }
trimDialUpErrorThreshold OBJECT-TYPE
SYNTAX INTEGER {
none(1),
low(2),
medium(3),
high(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Error rate on main link at which Backup will be enabled.
low - 1*10-5
medium - 5*10-4
high - 1*10-3
If none(1) is selected, then backup is not invoked when there are errors
on the main link, but only when the main link is down."
::= { trimBackup 5 }
trimDialUpRedialTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If an attempt to dial up failed for the specified time, a new redial attempt
will be initiated."
::= { trimBackup 6}
trimDialUpRedialNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable specifies the number of times to initiate the dial-up procedure.
If the number of redials is set to zero (0), then the number of redials will be
unlimited. Any other value will cause the dial-up procedure to terminate after
the specified number of re-dial attempts fail. Resetting this variable to any value
will re-initiate the dial-up procedure."
::= { trimBackup 7 }
trimBackUpConnectDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The connect delay defines the minimum time period that the link must be disconnected."
::= { trimBackup 8 }
trimBackUpDisConnectDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The disconnect delay defines the delay between the last valid traffic trigger
and link disconnection."
::= { trimBackup 9 }
trimBackUpScheduleTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrimBackUpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a table that contains the reroute shedule for the backup link. The index
is the day of the week, starting with 1 for Sunday, ending with 7 for
Saturday."
::= { trimBackup 10 }
trimBackUpEntry OBJECT-TYPE
SYNTAX TrimBackUpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table trimBackUpScheduleTable."
INDEX { trimBackUpDay }
::= { trimBackUpScheduleTable 1 }
TrimBackUpEntry ::= SEQUENCE {
trimBackUpDay
Integer32,
trimBackUpFromTo
DisplayString
}
trimBackUpDay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The day of the week for which the entry applies. The days are numbered from
1 to 7, representing Monday through Sunday."
::= { trimBackUpEntry 1 }
trimBackUpFromTo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the time during which backup should be disabled, expressed
as xx:xx-yy:yy, where x's reflect the time from and y's reflect the time
to. The first two digits, in x and in y, are the hour and the second two
digits are the minutes. The pairs of digits are separated by a colon, and the
x is separated from the y by a dash."
::= { trimBackUpEntry 2 }
trimBackUpDelayAfterFailure OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry defines the delay between the last @@@@"
::= { trimBackup 11 }
-- The trimTR group defines parameters for Token Ring interface management, in addition to parameters
-- defined in the Public Token Ring MIB (RFC 1231).
trimTR OBJECT IDENTIFIER ::= { trim 3 }
trimTRIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrimTRIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines configuration parameters for Token Ring interfaces in the Trimbridge-16."
::= { trimTR 1 }
trimTRIfEntry OBJECT-TYPE
SYNTAX TrimTRIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table trimTRIfTable."
INDEX { trimTRIfIndex }
::= { trimTRIfTable 1 }
TrimTRIfEntry ::= SEQUENCE {
trimTRIfIndex
Integer32,
trimTREarlyTokenRelease
INTEGER,
trimTRLocalAdminAddress
MacAddress,
trimTRLocalAdminAddressStatus
INTEGER
}
trimTRIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index to the Token Ring Interface Table. The interface defined by a
particular value of this index is the same interface as
identified by the same value of ifIndex (MIBII)."
::= { trimTRIfEntry 1 }
trimTREarlyTokenRelease OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter controls the early token release. This paramenter
is applicable only to 16 Mbps rings."
::= { trimTRIfEntry 2 }
trimTRLocalAdminAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A locally administered MAC Address of this interface."
::= { trimTRIfEntry 3 }
trimTRLocalAdminAddressStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter controls whether the bridge uses the locally administered MAC
Address defined for this interface, when enable(1), or not , when disable(2)."
::= { trimTRIfEntry 4 }
-- The trimTrapInfo group provides information on traps sent from Trimbridge
trimTrapInfo OBJECT IDENTIFIER ::= {trim 4}
trimErrorDesc OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual description of the enterprise-specific trap sent
to the Network Management Station by Trimbridge."
::= { trimTrapInfo 1 }
trimErrorSeverity OBJECT-TYPE
SYNTAX INTEGER {
information(1),
warning(2),
error(3),
fatal(4)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity type of the enterprise-specific trap sent to the
Network Management Station by Trimbridge."
::= { trimTrapInfo 2 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\lanrger4.txt
--
--Version: 1.0
--Date: 16.10.94
--By: Debby Koren & Orly Nicklass
--File: v:\doc\rdv\mib\ver540\Lanrger4.txt
--
--Last Update: 27-Feb-2008 by Smadar Tauber
-- Comments: The LANRANger also supports the following Public MIBs:
-- - MIB-II ( RFC1213 )
-- - Token Ring MIB (RFC 1231) or Ethernet MIB (RFC 1398), according to the LAN
-- interface
-- - RS-232 MIB (RFC 1317)
lanranger OBJECT IDENTIFIER ::= {radBridges 2 }
-- Objects in this MIB are arranged into groups:
-- lanrangerConfig - LANRANger-specific configurable parameters
-- lanrangerInterface - LANRANger-specific interface table
-- lanrangerStation - Tables containing the list of remote workstations and related information
-- and static entries
-- At the end of the MIB there is a definition of all LANRANger-specific traps.
-- the lanrangerConfig group defines configurable parameters that are specific to the LANRANger
-- product line
lanrangerConfig OBJECT IDENTIFIER ::= { lanranger 1 }
lanrangerLoc OBJECT-TYPE
SYNTAX INTEGER {
main(1),
remote(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"lanrangerLoc is set to main if the LANRANger is located on the main LAN and it is set to
remote if it is located on a LAN at a remote site."
::= { lanrangerConfig 1 }
lanrangerBurnAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the burned-in MacAddress on the LANRANger."
::= { lanrangerConfig 2 }
lanrangerLocAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is a locally administered address. If a zero value appears, the network administrator
did not set a locally administered address."
::= { lanrangerConfig 3 }
lanrangerActiveAddress OBJECT-TYPE
SYNTAX INTEGER {burnedIn(1), locallyAdministered(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MAC address that is in use on the LANRANger.
The address selected will appear in ifPhysAddress."
::= { lanrangerConfig 4 }
lanrangerLearningStationTopology OBJECT-TYPE
SYNTAX INTEGER { dynamic (1),
permanent (2),
permanentAndDynamic (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Learning station topology defines for the
LANRANger which type of station will be inserted
in the station list.
The default value is permanentAndDynamic(3).
dynamic(1) - Learning lan station only.
permanent(2) -
permanentAndDynamic(3)-
Setting this parameter will reset the LANRANger .
----- "
::= { lanrangerConfig 5 }
lanrangerIpRouterInfo OBJECT IDENTIFIER
::= { lanrangerConfig 6 }
lanrangerIpDefaultLink OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The default selected link, having the numbering system of ifIndex.
The valid values range is: 1..ifIndex.
The value must remain constant at least from one
re-initialization of the network management agent to
the next.
notSupported = 255 "
::= { lanrangerIpRouterInfo 1 }
lanrangerIpFastReTxLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The maximum buffer depth (queue length) for which lanranger
will accept retransmission (for each station; the level
is the same for all the stations).
The valid values range is: 1..255 . "
::= { lanrangerIpRouterInfo 2 }
lanrangerIpAgingTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Ip aging time for a station - in min. "
::= { lanrangerIpRouterInfo 3 }
--BOOT-P parameters; are relevant only for routers
lanrangerIpBootP OBJECT IDENTIFIER
::= { lanrangerIpRouterInfo 4 }
lanrangerBootPAction OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Activating (disable/enable) the BootP operation."
::= { lanrangerIpBootP 1 }
lanrangerBootPAvailableEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of available entries in the BootP table."
::= { lanrangerIpBootP 2 }
lanrangerBootPCurrentEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of BootP entries in the BootP table."
::= { lanrangerIpBootP 3 }
lanrangerBootPTable OBJECT-TYPE
SYNTAX SEQUENCE OF LanrangerBootPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of BootP entries. The number of entries is up to
BootP current entries, according to the LANRANger model."
::= { lanrangerIpBootP 4 }
lanrangerBootPEntry OBJECT-TYPE
SYNTAX LanrangerBootPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"BootP parameters per entry of the BootP table."
INDEX { lanrangerBootPIpAddress }
::= { lanrangerBootPTable 1 }
LanrangerBootPEntry ::=
SEQUENCE {
lanrangerBootPIpAddress
IpAddress,
lanrangerBootPIfIndex
INTEGER,
lanrangerBootPOperation
INTEGER
}
lanrangerBootPIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"BootP Ip Address."
::= { lanrangerBootPEntry 1 }
lanrangerBootPIfIndex OBJECT-TYPE
SYNTAX INTEGER {notAllocated (255)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number is the same as the ifIndex of the link."
::= { lanrangerBootPEntry 2 }
lanrangerBootPOperation OBJECT-TYPE
SYNTAX INTEGER {
active (1),
delete (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the status of this entry.
active(1) - this entry is currently in use
and will remain so even after the next
reset of the LANRANger.
delete(2) - writing this value to the object,
removes the corresponding entry from the
table. "
::= { lanrangerBootPEntry 3 }
lanrangerSpoofingInfo OBJECT IDENTIFIER
::= { lanrangerConfig 7 }
lanrangerSpoofingAction OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Spoofing action is applied by bit code:
enable : bit 0 set (disable: bit 0 is 0)
keepAlive : bit 1
... : bit 2
and so on.
For the above example, to set spoofing to keepAlive action,
the object's value will be 3 = [ 2**0 + 2**1 ]
Only the Remote LANRANger will accept this object !
------- "
::= { lanrangerSpoofingInfo 1 }
lanrangerSpoofingAgingStation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Aging time of stations list, in min. The agent 'translates'
the time entered in minutes, to 10 min. resolution, as
follows:
1..10 min - 10 min
11..20 min - 20 min
and so on...
0 is not a valid value.
Only the Remote LANRANger will accept this object !
---------------- "
::= { lanrangerSpoofingInfo 2 }
-- The variables in the lanrangerInterface group define LANRANger-specific and other
-- link parameters and information
lanrangerInterface OBJECT IDENTIFIER ::= { lanranger 2 }
lanrangerLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF LanrangerLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of link entries. The number of entries is
up to 8, according to the LANRANger model."
::= { lanrangerInterface 1 }
lanrangerLinkEntry OBJECT-TYPE
SYNTAX LanrangerLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"LANRANger-specific parameter values for a link."
INDEX {lanrangerLinkIndex }
::= { lanrangerLinkTable 1 }
LanrangerLinkEntry ::=
SEQUENCE {
lanrangerLinkIndex
Integer32,
lanrangerLinkType
INTEGER ,
lanrangerLinkState
INTEGER,
lanrangerLinkDTRMode
INTEGER,
lanrangerLinkStatus
INTEGER,
lanrangerLinkConnectionStatus
INTEGER,
lanrangerLinkNumOfLogLinks
Integer32,
lanrangerLinkReset
INTEGER,
lanrangerLinkRxMaskedFrames
Counter32,
lanrangerLinkLayer2Type
INTEGER,
lanrangerLinkLayer3Type
INTEGER,
lanrangerBackupLink
Integer32,
wrWanThrottle
Integer32,
wrIpTransparentMode
INTEGER,
wrIpTransparentGateway
IpAddress,
lanrangerLinkProtocolType
INTEGER
}
lanrangerLinkIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value for each link, equal to the value of ifIndex.
The value for each link must remain constant at least
from one re-initialization of the network management agent to
the next."
::= { lanrangerLinkEntry 1 }
lanrangerLinkType OBJECT-TYPE
SYNTAX INTEGER {
synchronous (1),
asynchronous (2),
x25FRconfig (3),
x25FRchannel (4),
isdn (5),
frameRelay (6),
pcmcia (7),
dm2wire (8),
notExist (254),
unknown (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The link type ."
::= { lanrangerLinkEntry 2 }
lanrangerLinkState OBJECT-TYPE
SYNTAX INTEGER {
disable(2),
enable (3),
backup (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The link is disabled, enabled or backup."
::= { lanrangerLinkEntry 3 }
lanrangerLinkDTRMode OBJECT-TYPE
SYNTAX INTEGER { off(2), on(3), unknown(255) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link DTR mode."
::= { lanrangerLinkEntry 4 }
lanrangerLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
ok (1),
fail (2),
rxNoClock (3),
txProblem (4),
noCarrierD (5),
unknown (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link physical status ."
::= { lanrangerLinkEntry 5 }
lanrangerLinkConnectionStatus OBJECT-TYPE
SYNTAX INTEGER {
fail (1),
disconnect(2),
connect (3),
wait (4),
down (5),
trying (6),
testing (7),
unknown (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link connection status."
::= { lanrangerLinkEntry 6 }
lanrangerLinkNumOfLogLinks OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of logical links on this physical link.
0 = noLogicalLink "
::= { lanrangerLinkEntry 7 }
lanrangerLinkReset OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON will reset the link . Upon completion the value will be set to OFF"
::= { lanrangerLinkEntry 8 }
lanrangerLinkRxMaskedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of masked frames received on this physical link."
::= { lanrangerLinkEntry 9 }
lanrangerLinkLayer2Type OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
bridge (2),
ipRouter (3),
ipxRouter (4),
ipAndIpxRouter (5),
bRouter (6),
ipBrouter (7),
ipxBrouter (8),
ipAndIpxBrouter (9),
bridgeAndStp (10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The link layer 2 type indicates whether the link is Bridge
or Router and specifies the Router's type."
::= { lanrangerLinkEntry 10 }
lanrangerLinkLayer3Type OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
proprietary (2),
terminalServer (3),
slip (30),
cSlip (31),
ppp (40),
rfc1490 (41),
hdlcFraming (42),
mlPpp (43)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The link layer 3 type indicates the protocol type."
::= { lanrangerLinkEntry 11 }
lanrangerBackupLink OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The backup link interface index located in the two LSB bytes.
If the link is FR type, the two MSB will contain a DLCi number.
For other link types the two MSB will equal to 0."
::= { lanrangerLinkEntry 12 }
wrWanThrottle OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Throttle controls the baud rate of the WAN.
For example if we have a WAN rate of 2M but we want only 1/2 M as
the baud rate we set the Wan Throttle to 512k.
These are the values:
Full (2),
1M (3),
512k (4),
128k (5),
64k (6)
Full throttle option (2) means the LAN rate."
::= { lanrangerLinkEntry 13 }
wrIpTransparentMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
disable (2),
enableAll (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter shows whether the IP Transparent mode is enabled.
When this mode is enabled, all frames (including broadcast and multicast frames)
are forwarded from E1/T1 to LAN and from LAN to E1/T1."
::= { lanrangerLinkEntry 14 }
wrIpTransparentGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gateway used for transparent IP."
::= { lanrangerLinkEntry 15 }
lanrangerLinkProtocolType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
noRoutingProtocol (2),
rip1 (3),
rip2 (4),
rip1OrRip2 (5),
ospf (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the routing protocol running on this Interface."
::= { lanrangerLinkEntry 16}
--Link Connections
lanrangerLinkConnection OBJECT IDENTIFIER
::= { lanrangerInterface 2 }
lanrangerConnMaxEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of entries in the Connection table."
::= { lanrangerLinkConnection 1 }
lanrangerConnCurrentEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of entries in the Connection table."
::= { lanrangerLinkConnection 2 }
lanrangerLinkConnTable OBJECT-TYPE
SYNTAX SEQUENCE OF LanrangerLinkConnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Connection entries. The number of entries is
up to Max entries, according to the LANRANger model."
::= { lanrangerLinkConnection 3 }
lanrangerLinkConnEntry OBJECT-TYPE
SYNTAX LanrangerLinkConnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about LANRANger Connection."
INDEX {lanrangerLinkConnPhysLink, lanrangerLinkConnAid,
lanrangerLinkConnMacAddr }
::= { lanrangerLinkConnTable 1 }
LanrangerLinkConnEntry ::=
SEQUENCE {
lanrangerLinkConnPhysLink
Integer32 ,
lanrangerLinkConnAid
Integer32,
lanrangerLinkConnMacAddr
MacAddress,
lanrangerLinkConnStatus
INTEGER,
lanrangerLinkConnDeviceType
INTEGER,
lanrangerLinkConnDeviceName
DisplayString,
lanrangerLinkConnDeviceSWVer
DisplayString,
lanrangerLinkConnNumLanStation
Integer32,
lanrangerLinkSyncStatus
INTEGER
}
lanrangerLinkConnPhysLink OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lanrangerLinkIndex for the physical link with which this logical link is associated."
::= { lanrangerLinkConnEntry 1 }
lanrangerLinkConnAid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value for each logical link. The maximum number
of logical links is 256, according to the LANRANger model.
The value for each logical link must remain constant at least
from one re-initialization of the network management agent to
the next. This index is the SPS address of the logical link.
noLogicLink = 65535"
::= { lanrangerLinkConnEntry 2 }
lanrangerLinkConnMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC address of the device that the logical link is connected to
on the remote LAN."
::= { lanrangerLinkConnEntry 3 }
lanrangerLinkConnStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown (1), -- for router link
none (2), -- no connection
fail (3),
connect (4),
wait (5),
down (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link connection status."
::= { lanrangerLinkConnEntry 4 }
lanrangerLinkConnDeviceType OBJECT-TYPE
SYNTAX INTEGER {
tre1 (1),
tre8 (2),
tre1D (3),
tre8D (4),
tre8M (5),
rrTre (6),
rrTre1D (7),
rrTre8D (8),
iTre1 (9),
iTre2 (10),
mpTre8 (11),
kTre8 (12),
treRasA (13),
treRasS (14),
trePCAsync(15),
trePCSync (16),
mbe1 (17),
mbe8 (18),
mbe1D (19),
mbe8D (20),
ete8M (21),
iEre1 (22),
iEe2 (23),
mpMbe8 (24),
kMbe8 (25),
mbePCAsync(26),
mbePCSync (27),
mbeRasA (28),
mbeRasS (29),
other(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of device that the logical link is connected to on the remote LAN."
::= { lanrangerLinkConnEntry 5 }
lanrangerLinkConnDeviceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The logical name of the device that the logical link is connected to on the remote LAN."
::= { lanrangerLinkConnEntry 6 }
lanrangerLinkConnDeviceSWVer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SW Version of the device that the logical link is
connected to, on the remote LAN."
::= { lanrangerLinkConnEntry 7 }
lanrangerLinkConnNumLanStation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of stations of the remote LAN."
::= { lanrangerLinkConnEntry 8 }
lanrangerLinkSyncStatus OBJECT-TYPE
SYNTAX INTEGER {
synchronized (1),
syncNotObtained (2),
waitForSync (3),
codDisconnected (4),
lcp (5),
ip (6),
ipvj (7),
ipx (8),
ipIpx (9),
ipvj-ipx (10),
mlPpp (11),
mlPpp-ip (12),
mlPpp-ip-ipvj (13),
mlPpp-ip-ipx (14),
mlPpp-ipvj-ipx (15),
mlPpp-ipx (16),
frUp (17),
frDown (18),
dlciUp (19),
dlciDown (20),
extLoop (21),
ipcp (22),
lcpIpcp (23),
redAlarm (24),
yellowAlarm (26),
localSyncLoss (27),
remoteSyncLoss (28),
networkLoop (29),
networkLoopRedAlarm (30),
networkLoopYelAlarm (31),
networkLocSyncLoss (32),
networkRemSyncLoss (33),
fdlLoop (34),
fdlLoopRedAlarm (35),
fdlLoopYellowAlarm (36),
fdlLoopLocSyncLoss (37),
fdlLoopRemSyncLoss (38),
loopback (39), -- User Loop
loopbackLocSyncLoss (40),
loopbackRemSyncLoss (41)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Sync link status."
::= { lanrangerLinkConnEntry 9 }
--Modem Table
lanrangerModemTable OBJECT-TYPE
SYNTAX SEQUENCE OF LanrangerModemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Modem entries. The number of entries is
up to ifIndex."
::= { lanrangerInterface 3 }
lanrangerModemEntry OBJECT-TYPE
SYNTAX LanrangerModemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"LANRANger-specific parameter values for a Modem."
INDEX {lanrangerModemLinkIndex }
::= { lanrangerModemTable 1 }
LanrangerModemEntry ::=
SEQUENCE {
lanrangerModemLinkIndex
Integer32,
lanrangerModemName
DisplayString,
lanrangerModemSettingString
DisplayString,
lanrangerModemAutobaudingSpeed
INTEGER,
lanrangerModemResetBeforeSetup
INTEGER,
lanrangerModemAnalyzeAnswers
INTEGER,
lanrangerModemSpeaker
INTEGER,
lanrangerModemDialingNumber
DisplayString,
lanrangerModemDialRetries
Integer32,
wrLocalDialBackNumber
DisplayString,
wrRingsBeforeAnswer
Integer32
}
lanrangerModemLinkIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A list of asynchronous ports of the link, according to
ifIndex.
Synchronous ports will not appear in this table. Their
port number will be skipped."
::= { lanrangerModemEntry 1 }
lanrangerModemName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Modem Name identifier for MBE/TRE.
Up to 50 characters."
::= { lanrangerModemEntry 2 }
lanrangerModemSettingString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Modem setting String.
Up to 80 characters."
::= { lanrangerModemEntry 3 }
lanrangerModemAutobaudingSpeed OBJECT-TYPE
SYNTAX INTEGER {
disable(2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable autobauding.
When the Autobauding feature is enabled, the MBE/TRE
automatically ranges over various Baud rates, starting
with 115.2 Kbps, until the correct Baud rate of the modem
is detected. "
::= { lanrangerModemEntry 4 }
lanrangerModemResetBeforeSetup OBJECT-TYPE
SYNTAX INTEGER {
no (2),
yes(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset the modem before setup is performed.
It is recommended to reset the modem before modem setup
session. "
::= { lanrangerModemEntry 5 }
lanrangerModemAnalyzeAnswers OBJECT-TYPE
SYNTAX INTEGER {
disable(2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable this option if a modem using non-standard answering is used.
When this mode is enabled, the MBE/TRE awaits modem answers
'CONNECT', 'CARRIER', or 'OK', after it transmits a modem command.
Modem answers acknowledge, that a specific command has been executed.
If this option is not enabled, the MBE/TRE waits for a modem answer
for three seconds. If no answer has been received during this period,
the MBE/TRE continues functioning as if the modem command was successfully
executed. However, when dialing out, the MBE/TRE waits for one minute
for connection."
::= { lanrangerModemEntry 6 }
lanrangerModemSpeaker OBJECT-TYPE
SYNTAX INTEGER {
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Toggle the Modem Speaker On or Off . "
::= { lanrangerModemEntry 7 }
lanrangerModemDialingNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Various command switches listed in Modem Dialing Number Menu
allows selection of tone, pulse-dialing, or various wait states.
P - Set Pulse dialing number .
T - Set Tone dialing number .
W - Wait for dialing tone before proceeding.
' - Pause for 2 seconds .
@ - Wait for silence, one ring, followed by 5 sec. of silence .
The Dialing Number will include both digits and letter/s
of the command switches. The order and validity will be
on user's responsibility.
The DisplayString can have up to 40 characters."
::= { lanrangerModemEntry 8 }
wrLocalDialBackNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This is the number that the Remote Modem will use to call the local
Modem at Dial Back.
Various command switches listed in Modem Dialing Number Menu
allows selection of tone, pulse-dialing, or various wait states.
P - Set Pulse dialing number .
T - Set Tone dialing number .
W - Wait for dialing tone before proceeding.
' - Pause for 2 seconds .
@ - Wait for silence, one ring, followed by 5 sec. of silence .
The Dialing Number will include both digits and letter/s
of the command switches. The order and validity will be
on user's responsibility.
The DisplayString can have up to 40 characters."
::= { lanrangerModemEntry 9 }
wrRingsBeforeAnswer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines which ring the modem will wait to answer the
phone on."
::= { lanrangerModemEntry 10 }
lanrangerModemDialRetries OBJECT-TYPE
SYNTAX Integer32 (0..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of dialing retries requested.
Default = 0"
::= { lanrangerModemEntry 11}
--Packet Switch Table
lanrangerLinkPktSwTable OBJECT-TYPE
SYNTAX SEQUENCE OF LanrangerLinkPktSwEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of X.25/FR modules entries. The number of entries is
up to ifIndex."
::= { lanrangerInterface 4 }
lanrangerLinkPktSwEntry OBJECT-TYPE
SYNTAX LanrangerLinkPktSwEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"LANRANger-specific parameter values for X.25/FR modules."
INDEX {lanrangerLinkPktSwIndex }
::= { lanrangerLinkPktSwTable 1 }
LanrangerLinkPktSwEntry ::=
SEQUENCE {
lanrangerLinkPktSwIndex
Integer32,
lanrangerLinkPktSwType
INTEGER,
lanrangerLinkPktSwControlSignal
INTEGER,
lanrangerLinkPktSwSpeed
Integer32,
lanrangerLinkPktSwConfigParity
INTEGER,
lanrangerLinkPktSwConfigStopBit
INTEGER,
lanrangerLinkPktSwResetModule
INTEGER
}
lanrangerLinkPktSwIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value for each X.25/FR of the link, according to
numbering system of ifIndex. The maximum number of links is
ifIndex. The value for each link must remain constant at
least from one re-initialization of the network management
agent to the next."
::= { lanrangerLinkPktSwEntry 1 }
lanrangerLinkPktSwType OBJECT-TYPE
SYNTAX INTEGER {
x25FRChannel (1),
x25FRConfig (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packet Switch Type."
::= { lanrangerLinkPktSwEntry 2 }
lanrangerLinkPktSwControlSignal OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Packet Switch control command. "
::= { lanrangerLinkPktSwEntry 3 }
lanrangerLinkPktSwSpeed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Pkt Switch port's speed in bits per second.
Range: 1200bps .. 1544000bps"
::= { lanrangerLinkPktSwEntry 4 }
lanrangerLinkPktSwConfigParity OBJECT-TYPE
SYNTAX INTEGER { none(1), odd(2), even(3), notApplicable(255)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Pkt Switch Config port's character parity bit.
Applicable only for x25FRConfigChannel. For x25FRChannel
the value notApplicable applies."
::= { lanrangerLinkPktSwEntry 5 }
lanrangerLinkPktSwConfigStopBit OBJECT-TYPE
SYNTAX INTEGER { one(1), two(2), notApplicable(255) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Pkt Switch Config port's number of stop bits.
Applicable only for x25FRConfigChannel. For x25FRChannel
the value notApplicable applies."
::= { lanrangerLinkPktSwEntry 6 }
lanrangerLinkPktSwResetModule OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset command to Pkt Switch module.
Applicable only for x25FRChannel.
The command will have no effect on x25FRConfigChannel."
::= { lanrangerLinkPktSwEntry 7 }
-- lanrangerStation group contains a list of remote workstations and related information
lanrangerStation OBJECT IDENTIFIER ::= {lanranger 3}
lanrangerStationTable OBJECT-TYPE
SYNTAX SEQUENCE OF LanrangerStationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains information about the stations
on the remote LAN(s).
A remote LANRANger contains a list of stations on its
LAN, while a main LANRANger contains a list of
stations at all the remote sites it is connected to."
::= { lanrangerStation 1 }
lanrangerStationEntry OBJECT-TYPE
SYNTAX LanrangerStationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a specific station, that the LANRANger
lists as being on a remote LAN."
INDEX { lanrangerStationPhysLink, lanrangerStationLogLink, lanrangerStationAddress}
::= { lanrangerStationTable 1 }
LanrangerStationEntry ::=
SEQUENCE {
lanrangerStationPhysLink
Integer32,
lanrangerStationLogLink
Integer32,
lanrangerStationAddress
MacAddress,
lanrangerStationStatus
INTEGER,
lanrangerStationSpoofingStatus
INTEGER
}
lanrangerStationPhysLink OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the physical link that is connected to the
remote LAN on which the station with the associated
instance of lanrangerStationAddress is located. The number
is the same as the ifIndex of the link. The value will be
zero on a remote LANRANger"
::= { lanrangerStationEntry 1 }
lanrangerStationLogLink OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the logical link that is connected
to the remote LAN on which the station with the associated
instance of lanrangerStationAddress is located. The value
will be zero on a remote LANRANger.
noLogicLink = 65535"
::= { lanrangerStationEntry 2 }
lanrangerStationAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unicast MAC address of a station that the LANRANger
lists as being on a remote LAN."
::= { lanrangerStationEntry 3 }
lanrangerStationStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
learned(2),
self (3),
static (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of this entry. The meanings of the
values are:
unknown(1) :
learned(2) : the value of the corresponding
instance of lanrangerStationAddress was
learned and is being used.
self(3) : the value of the corresponding
instance of lanrangerStationAddress
represents the LANRANger's address.
static(4) : the value of the corresponding
instance of lanrangerStationAddress is
also the value of an existing
instance of lanrangerStaticAddress."
::= { lanrangerStationEntry 4 }
lanrangerStationSpoofingStatus OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The spoofing status of this entry."
::= { lanrangerStationEntry 5 }
lanrangerLanMaxStations OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of stations in the station table."
::= { lanrangerStation 2 }
lanrangerLanCurrentStations OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of stations in the station table."
::= { lanrangerStation 3 }
--Permanent Stations
lanrangerPermanentStation OBJECT IDENTIFIER
::= { lanrangerStation 4 }
lanrangerPermanentMaxEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of entries in the permanent stations table."
::= { lanrangerPermanentStation 1 }
lanrangerPermanentCurrentEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of entries in the permanent stations table."
::= { lanrangerPermanentStation 2 }
lanrangerPermanentTable OBJECT-TYPE
SYNTAX SEQUENCE OF LanrangerPermanentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing address information
configured into the LANRANger by (local or network)
management, specifying addresses on a remote LAN.
This table objects can be set only on a Remote LANRANger."
::= { lanrangerPermanentStation 3 }
lanrangerPermanentEntry OBJECT-TYPE
SYNTAX LanrangerPermanentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Address information configured into the remote LANRANger
by (local or network) management specifying addresses
on a remote LAN."
INDEX { lanrangerPermanentIfIndex, lanrangerPermanentLogLink,
lanrangerPermanentAddress }
::= { lanrangerPermanentTable 1 }
LanrangerPermanentEntry ::=
SEQUENCE {
lanrangerPermanentIfIndex
Integer32,
lanrangerPermanentLogLink
Integer32,
lanrangerPermanentAddress
MacAddress,
lanrangerPermanentOperation
INTEGER
}
lanrangerPermanentIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the physical link that is connected to
the remote LAN, on which the station with the
associated instance of lanrangerStationAddress is
located.
The number is the same as the ifIndex of the link.
This data is interesting for main LANRANger only."
::= { lanrangerPermanentEntry 1 }
lanrangerPermanentLogLink OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the logical link that is connected to the
remote LAN, on which the station with the associated
instance of lanrangerPermanentAddress is located.
The value will be noLogicLink on a remote LANRANger.
This data is interesting for main LANRANger only.
noLogicLink = 65535"
::= { lanrangerPermanentEntry 2 }
lanrangerPermanentAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC address entered by management to this entry.
Only the remote LANRANger will accept Set for this object !
---------------- "
::= { lanrangerPermanentEntry 3 }
lanrangerPermanentOperation OBJECT-TYPE
SYNTAX INTEGER {
active (1),
delete (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the status of this entry.
active(1) - this entry is currently in use
and will remain so even after the next
reset of the LANRANger.
delete(2) - writing this value to the object
removes the corresponding entry.
Only the remote LANRANger will accept Set for this object !
---------------- "
::= { lanrangerPermanentEntry 4 }
--IP Stations
lanrangerIpStation OBJECT IDENTIFIER
::= { lanrangerStation 5 }
lanrangerIpPermanentAvailableEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The available number of entries in the IP permanent stations
table."
::= { lanrangerIpStation 1 }
lanrangerIpPermanentCurrentEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of entries in the IP permanent station table."
::= { lanrangerIpStation 2 }
-- The IP Permanent Stations table will be supported via the
-- IP Forward table of RFC1354.MIB.
lanrangerSpoofingStation OBJECT IDENTIFIER
::= {lanrangerStation 6}
lanrangerSpoofingMaxEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of entries in the Spoofing station
table."
::= {lanrangerSpoofingStation 1}
lanrangerSpoofingCurrentEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of entries in the Spoofing station
table."
::= {lanrangerSpoofingStation 2}
lanrangerSpoofingTable OBJECT-TYPE
SYNTAX SEQUENCE OF LanrangerSpoofingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Spoofing entries. The number of entries is
up to the current number of entries, according to the
LANRANger model.
Only the LOCAL LANRANger will show this table !
--------------- "
::= { lanrangerSpoofingStation 3 }
lanrangerSpoofingEntry OBJECT-TYPE
SYNTAX LanrangerSpoofingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Spoofing parameters per entry of the Spoofing table."
INDEX {lanrangerSpoofingGroup, lanrangerSpoofingMacAddress }
::= { lanrangerSpoofingTable 1 }
LanrangerSpoofingEntry ::=
SEQUENCE {
lanrangerSpoofingGroup
Integer32,
lanrangerSpoofingMacAddress
MacAddress ,
lanrangerSpoofingAging
Integer32,
lanrangerSpoofingTimeLeft
Integer32
}
lanrangerSpoofingGroup OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The spoofing group.
Only the LOCAL Lanranger will show this table ! "
::= { lanrangerSpoofingEntry 1 }
lanrangerSpoofingMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" MAC Address of the Remote Lanrangers.
Only the LOCAL Lanranger will show this table ! "
::= { lanrangerSpoofingEntry 2 }
lanrangerSpoofingAging OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Aging time defined for a whole group, in minutes.
Only the LOCAL Lanranger will show this table ! "
::= { lanrangerSpoofingEntry 3 }
lanrangerSpoofingTimeLeft OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Time until aging expires, per station, in minutes.
Only the LOCAL Lanranger will show this table ! "
::= { lanrangerSpoofingEntry 4 }
--PPP Table for the WebRanger
wrPPPTable OBJECT-TYPE
SYNTAX SEQUENCE OF WrPPPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains only parameters that do not exist in the PPP
standard MIBS.
The table contains a list of PPP entries.
The number of entries is up to ifIndex."
::= { lanrangerInterface 5 }
wrPPPEntry OBJECT-TYPE
SYNTAX WrPPPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"LANRANger-specific parameter values for a PPP."
INDEX {ifIndex }
::= { wrPPPTable 1 }
WrPPPEntry ::=
SEQUENCE {
wrPPPCompressionHeaderField INTEGER,
wrPPPCompressionProtocolFields INTEGER,
wrPPPSTACCompressionType INTEGER,
wrPPPAuthProtocol INTEGER,
wrPPPSecurityType INTEGER,
wrPPPUserName SnmpAdminString,
wrPPPPassword SnmpAdminString,
wrPPPLinkActiveTime Integer32,
wrPPPIPCPSubnetMaskNegotiation InterfaceIndexOrZero,
wrPPPLinkControlProtocolStatus INTEGER,
wrPPPAuthenticationStatus INTEGER,
wrPPPIpcpStatus INTEGER,
wrPPPAssignedIPAddress IpAddress,
wrPPPActualAuthProtocol INTEGER,
wrPPPIpTranslationMode INTEGER,
wrPPPTranslatedIpAddr IpAddress
}
wrPPPCompressionHeaderField OBJECT-TYPE
SYNTAX INTEGER
{ compressionOff (2),
compressionOn (3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This configuration option provides a method to negotiate the
compression of the Data Link Layer Address and Control fields.
This configuration option is sent to inform the peer that the
implementation can receive compressed Address and Control fields."
::= { wrPPPEntry 1 }
wrPPPCompressionProtocolFields OBJECT-TYPE
SYNTAX INTEGER
{ compressionOff (2),
compressionOn (3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This configuration option provides a method to negotiate the
compression of the PPP Protocol field. This configuration option
is sent to inform the peer that the implementation can receive
such single octet Protocol fields. "
::= { wrPPPEntry 2 }
wrPPPSTACCompressionType OBJECT-TYPE
SYNTAX INTEGER
{ disable (1),
noHistory (2),
lCB (3),
sequence (4),
extended (5) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The PPP compression control protocol provides a method to negotiate
and utilize compression protocol over PPP encapsulated links.
These are Different types of data compression algorithm for PPP
encapsulated packets. "
::= { wrPPPEntry 3 }
wrPPPAuthProtocol OBJECT-TYPE
SYNTAX INTEGER
{
noneNone (1),
chapNone (2),
chapPap (3),
chapChap (4),
papNone (5),
papPap (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of authentication protocol being used. The left parameter
is the maximum authentication, the right parameter is minimum authentication."
::= { wrPPPEntry 4 }
wrPPPSecurityType OBJECT-TYPE
SYNTAX INTEGER
{
host (1),
guest (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Type of unit."
::= { wrPPPEntry 5 }
wrPPPUserName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..36))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"PPP User name."
::= { wrPPPEntry 6 }
wrPPPPassword OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..36))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"PPP Password ."
::= { wrPPPEntry 7 }
wrPPPLinkActiveTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"PPP link active time in seconds
Values range: 2 - 900.
Default value = 2 "
::= { wrPPPEntry 8 }
wrPPPIPCPSubnetMaskNegotiation OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the ifIndex of the link (LAN port)
through which IPCP Subnet Mask negotiation is allowed.
The distinguished value of zero may be used if no link
is enabled for IPCP Subnet Mask negotiation.
For LA-110, IPCP Subnet Mask support allows Customer Premises
Equipment (CPE) to connect to a Broadband Access Server (BAS)
and obtain an IP address and subnet range that the CPE can
use to populate the DHCP server database. The IP address
is also used to configure an IP interface over the LAN port.
The IP Address is dynamically allocated by the DHCP Server,
using the DHCP Pool that was allocated over the PPP connection.
In order to connect one of the LANs to Subnet Mask Negotiation,
its IP Address should be 0.0.0.0. When the IP Address is allocated
from the PPP, the 0.0.0.0 IP Address is replaced in the data base
by the allocated IP Address. Only one Subnet Mask Negotiation on WAN
interface can be enabled at the same time in order to avoid
allocating the LAN IP address according to a few WAN
interfaces (a one-on-one connection).
The linked LAN interface can be deleted only after disabling the
Subnet Mask Negotiation on the PPP connection."
::= { wrPPPEntry 9 }
wrPPPLinkControlProtocolStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
close (2),
open (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PPP Link Control Protocol(LCP) Status"
::= { wrPPPEntry 10 }
wrPPPAuthenticationStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
failed (2),
passed (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PPP Authentication status."
::= { wrPPPEntry 11 }
wrPPPIpcpStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
close (2),
open (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IPCP (IP Control Protocol) status."
::= { wrPPPEntry 12}
wrPPPAssignedIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP Address assigned by PPP."
::= { wrPPPEntry 13}
wrPPPActualAuthProtocol OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
pap (2),
chap (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Actual type of Authentication Protocol that is used."
::= { wrPPPEntry 14 }
wrPPPIpTranslationMode OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables the IP Translation Mode."
::= { wrPPPEntry 15 }
wrPPPTranslatedIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the Translated IP Address.
It is relevant only when IP Translation Mode is 'enable'."
::= { wrPPPEntry 16 }
-- ML-PPP (Multilink PPP) Table
wrMLPPPTable OBJECT-TYPE
SYNTAX SEQUENCE OF WrMLPPPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains a list of ML-PPP entries."
::= { lanrangerInterface 6 }
wrMLPPPEntry OBJECT-TYPE
SYNTAX WrMLPPPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Specific parameter values for a ML-PPP."
INDEX {ifIndex }
::= { wrMLPPPTable 1 }
WrMLPPPEntry ::=
SEQUENCE {
wrMLPPPEpDiscriminatorEnable INTEGER,
wrMLPPPReorderingEnable INTEGER,
wrMLPPPTxQueueSize Unsigned32
}
wrMLPPPEpDiscriminatorEnable OBJECT-TYPE
SYNTAX INTEGER {
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the Endpoint Discriminator Option is enabled.
The Endpoint Discriminator Option represents identification of the
system transmitting the packet. This option advises a system that
the peer on this link could be the same as the peer on another
existing link. If the option distinguishes this peer from all
others, a new bundle MUST be established from the link being
negotiated. If this option matches the class and address of some
other peer of an existing link, the new link MUST be joined to the
bundle containing the link to the matching peer or MUST establish a
new bundle.
For more information about the Endpoint Discriminator Option -
see RFC-1990 (The PPP Multilink Protocol)."
::= { wrMLPPPEntry 1 }
wrMLPPPReorderingEnable OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether packets reordering option is enabled.
yes - packets received from MLPPP not in order are
reordered, according to sequence number,
before being transmitted to egress port.
no - received packets are transmitted in the
same order as they arrived."
::= { wrMLPPPEntry 2 }
wrMLPPPTxQueueSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the number of frames in the Tx Queue."
::= { wrMLPPPEntry 3 }
-- PPPoE (Point-to-Point Protocol over Ethernet)
pPPoE OBJECT IDENTIFIER ::= { lanrangerInterface 7 }
pPPoETable OBJECT-TYPE
SYNTAX SEQUENCE OF PPPoEEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The PPPoE (Point-to-Point Protocol over Ethernet) Table."
::= { pPPoE 1 }
pPPoEEntry OBJECT-TYPE
SYNTAX PPPoEEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the PPPoE Table."
INDEX { pPPoECnfgIdx, pPPoEID }
::= { pPPoETable 1 }
PPPoEEntry ::=
SEQUENCE {
pPPoECnfgIdx Unsigned32,
pPPoEID Unsigned32,
pPPoERowStatus RowStatus,
pPPoEACName SnmpAdminString,
pPPoEServiceName SnmpAdminString,
pPPoEEntityPointer RowPointer,
pPPoESessionStatus INTEGER,
pPPoESessionID Unsigned32,
pPPoERemoteMacAddr MacAddress,
pPPoENoOfUsages Unsigned32,
pPPoESchedRestartMode INTEGER,
pPPoESchedRestartTime DisplayString,
pPPoESchedRestartRandomRange Unsigned32,
pPPoESchedRestartActualTime DisplayString,
pPPoEInitDelayRandomRange Unsigned32,
pPPoEInitActualDelay Unsigned32,
pPPoEVlanTagging INTEGER,
pPPoEVlanId Unsigned32,
pPPoEVlanPriority Unsigned32
}
pPPoECnfgIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the first index of the table.
It can serve for Configuration index or other."
::= { pPPoEEntry 1 }
pPPoEID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the PPPoE unique Identifier."
::= { pPPoEEntry 2 }
pPPoERowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables the user to create/delete entries in this table."
::= { pPPoEEntry 3 }
pPPoEACName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the Name of the Access Concentrator,
with which the PPPoE session should be established."
::= { pPPoEEntry 4 }
pPPoEServiceName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the Name of a specific Service
that will be requested on this PPPoE session."
::= { pPPoEEntry 5 }
pPPoEEntityPointer OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter represents the entity (interface/port etc)
that is connected to this PPPoE.
The value of this parameter is a pointer to an existing row of a table,
where the entity connected to this PPPoE is defined.
Example:
In case of an interface (from 2863.ifTable):
points to 'ifEntry' of corresponding row
= <ifEntry OID>.<ifIndex>
."
::= { pPPoEEntry 6 }
pPPoESessionStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
down (2),
up (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the Status of the PPPoE session."
::= { pPPoEEntry 7 }
pPPoESessionID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents PPPoE Session ID."
::= { pPPoEEntry 8 }
pPPoERemoteMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the MAC Address of the Access Concentrator,
with which the PPPoE session is established."
::= { pPPoEEntry 9 }
pPPoENoOfUsages OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of times this PPPoE is used."
::= { pPPoEEntry 10 }
pPPoESchedRestartMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents Scheduled Restart Mode."
::= { pPPoEEntry 11 }
pPPoESchedRestartTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents Scheduled Restart Time.
It is relevant only when Scheduled Restart Mode is 'enable'."
::= { pPPoEEntry 12 }
pPPoESchedRestartRandomRange OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents Scheduled Restart Random Range (in seconds).
It is relevant only when Scheduled Restart Mode is 'enable'.
A scheduled restart Random VALUE (number of seconds) is selected
within this Random Range.
This VALUE is added to configured Scheduled Restart Time, so that
Actual Restart Time = Configured Restart Time + VALUE,
in order to create a differentiation between all PPPoE entities
with the same configured Scheduled Restart Time.
Note:
When Random Range is 0 -->
Random VALUE must be 0 -->
Actual Restart Time = Configured Restart Time."
::= { pPPoEEntry 13 }
pPPoESchedRestartActualTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents Scheduled Restart Actual Time.
It is relevant only when Scheduled Restart Mode is 'enable'.
For calculation of this time - see pPPoESchedRestartRandomRange."
::= { pPPoEEntry 14 }
pPPoEInitDelayRandomRange OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the Initialization Delay Random Range (in seconds).
An initialization DELAY (number of seconds) is selected within this Random Range.
This DELAY is used to delay the initialization of every PPPoE session,
meaning that whenever a PPPoE session is reestablished,
the device will send the first PPPoE initialization packet (PADI)
only after this DELAY (in seconds).
Note:
When Random Range = 0 -->
there will be no delay in the initialization process."
::= { pPPoEEntry 15 }
pPPoEInitActualDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents Initialization Delay (in seconds),
as selected within Initialization Delay Random Range (pPPoEInitDelayRandomRange)."
::= { pPPoEEntry 16 }
pPPoEVlanTagging OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
untag (2),
tag (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the VLAN Tagging."
::= { pPPoEEntry 17 }
pPPoEVlanId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the VLAN ID."
::= { pPPoEEntry 18 }
pPPoEVlanPriority OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the VLAN Priority."
::= { pPPoEEntry 19 }
-- Traps for use by the LANRANger
--NOTIFICATIONS
lanrangerEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for the LANRANger."
::= { lanranger 0 }
lanrangerLogLinkUp NOTIFICATION-TYPE
OBJECTS { lanrangerLinkConnPhysLink, lanrangerLinkConnAid }
STATUS current
DESCRIPTION
"The lanrangerLogLinkUp trap indicates that the indicated logical link is connected."
::= { lanrangerEvents 1 }
lanrangerLogLinkDown NOTIFICATION-TYPE
OBJECTS { lanrangerLinkConnPhysLink, lanrangerLinkConnAid }
STATUS current
DESCRIPTION
"The lanrangerLogLinkDown trap indicates that the indicated logical link is disconnected."
::= { lanrangerEvents 2 }
lanrangerLanTableOverflow NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"The station table has the maximum number of addresses for the LANRANger."
::= { lanrangerEvents 3 }
lanrangerStatusChanged NOTIFICATION-TYPE
OBJECTS { agnLed }
STATUS current
DESCRIPTION
"The trap indicates changes in the device status ."
::= { lanrangerEvents 4 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\febftb.txt
--
-- Title: FEB MIB
-- Version: 1.0
-- Date: 29 August 94
-- By: Orly Nicklass
--File: febftb.txt
-- Comments: This MIB is for FEBs and FTBs. These bridges also support the following MIBs:
-- - MIB-II ( RFC1213 )
-- - BRIDGE - MIB ( RFC1493)
-- - FDDI MIB (RFC 1512)
-- The FDDI bridges also support the RAD General Bridge Branch, 164.4.1
-- Objects in this MIB are arranged into groups:
-- febFtbTranslation - Defines parameters for translation of Ethernet and Token-Ring to/from FDDI
-- febFtbStatus
-- At the end of the MIB there is a definition of all FDDI bridge-specific traps.
febFtb OBJECT IDENTIFIER ::= { radBridges 4 }
febFtbTranslation OBJECT IDENTIFIER ::= { febFtb 1 }
febFtbStatus OBJECT IDENTIFIER ::= { febFtb 2 }
febFtbTranslIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF FebFtbTranslIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The translation table defines which type of translation is required for each device interface. This is
particularly important for WAN links, as the translating device does not have a knowledge of the
target LAN type."
::= { febFtbTranslation 1 }
febFtbTranslIfEntry OBJECT-TYPE
SYNTAX FebFtbTranslIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the translation table."
INDEX { febFtbTranslIfIndex}
::= { febFtbTranslIfTable 1 }
FebFtbTranslIfEntry ::=
SEQUENCE {
febFtbTranslIfIndex
Integer32,
febFtbTunnelProtocol
OCTET STRING,
febFtbTranslIPXRawEthernet
INTEGER
}
febFtbTranslIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index to the Translation Table. The interface defined by a particular value of this index is the
same interface as identified by the same value of ifIndex (MIBII)."
::= { febFtbTranslIfEntry 1 }
febFtbTunnelProtocol OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IEEE 802.1h standard defines the tunneling for Appletalk I. This parameter enables the user
to specify Ethertype of an additional protocol to tunnel (e.g. IPX). For IPX, Enter 8137 to
translate Token Ring SNAP frames to Ethernet_SNAP frames (instead of Ethernet II).
Valid range of values: 05DC to FFFF (hex)
0000 (hex) - disables this function. "
::= { febFtbTranslIfEntry 2 }
febFtbTranslIPXRawEthernet OBJECT-TYPE
SYNTAX INTEGER {
ethernetRaw8023(1),
ethernet8022(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable defines the translation mode for IPX frames in standrad Token Ring format. It is
applicable to Ethernet interfaces (i.e. febFtbTranslSwitch variable has value Ethernet (2). ).
ethernetRaw8023: translate to Raw Ethernet frames (default)
ethernet8022: translate to Ethernet 802.2 frames."
::= { febFtbTranslIfEntry 3 }
febFtbLanTable OBJECT-TYPE
SYNTAX SEQUENCE OF FebFtbLanTabEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"."
::= { febFtbStatus 1 }
febFtbLanTabEntry OBJECT-TYPE
SYNTAX FebFtbLanTabEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the LanTab table."
INDEX { febFtbLanTabIfIndex}
::= { febFtbLanTable 1 }
FebFtbLanTabEntry ::=
SEQUENCE {
febFtbLanTabIfIndex
Integer32,
febFtbLanTabEntNumber
Integer32
}
febFtbLanTabIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable defines the related interface"
::= { febFtbLanTabEntry 1 }
febFtbLanTabEntNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable defines the number of entries in the LAN table reletaed to the specific interface"
::= { febFtbLanTabEntry 2 }
febFtbFaults OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable defines the current device faults. It is a 32 bits variable, where each bit represents
a unique fault"
::= { febFtbStatus 2 }
--NOTIFICATIONS
febFtbEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for FEBs and FTBs."
::= { febFtb 0 }
lanTableOverflow NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"The station table has the maximum number of addresses for the device."
::= { febFtbEvents 1 }
statusChanged NOTIFICATION-TYPE
OBJECTS {agnLed, agnIndication }
STATUS current
DESCRIPTION
"A change occured in agent status or leds."
::= { febFtbEvents 2 }
portFddiStatusChanged NOTIFICATION-TYPE
OBJECTS {fddimibPORTPCMState, agnLed }
STATUS current
DESCRIPTION
"The Fddi port status changed. fddimibPORTPCMState
value has become off, maint, active, connect, or exited
one of these states."
::= { febFtbEvents 3 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\mlb.txt
--
-- Title: RAD MLB MIB
--
--
-- Version: 1.0
-- Date: November, 20, 1994
-- By: Ricky Yaffe
-- File: mlb.txt
mlb OBJECT IDENTIFIER ::= { radBridges 5 }
-- Objects in this MIB are arranged into groups:
-- mlbConfig - MLB - specific configurable parameters
-- mlbAddress - MLB - Table containing the list of ports address .
-- At the end of the MIB there is a definition of all MLB - specific traps.
mlbConfig OBJECT IDENTIFIER ::= { mlb 1 }
mlbMibVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"mlb private mib version ."
::= { mlbConfig 1 }
mlbPanelMedia OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
copper(2),
fiberOptic(3),
notSupported (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The panel media. It can be fiber optic connector or STP+UTP
in case of copper"
::= { mlbConfig 2 }
mlbRRFrontPanelPort OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
secondary(2),
main(3),
notSupported (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Front panel port function : MainPort / Sec.Port (case of RADring card) ."
::= { mlbConfig 3 }
mlbRRTermination OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
on(2),
off(3),
notSupported (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temination switch - Split back lan and Terminate it. (case of RADring card) ."
::= { mlbConfig 4 }
mlbAddress OBJECT IDENTIFIER ::= {mlb 2}
mlbAddressTable OBJECT-TYPE
SYNTAX SEQUENCE OF MlbAddressEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains information about the MLB ports address ."
::= { mlbAddress 1 }
mlbAddressEntry OBJECT-TYPE
SYNTAX MlbAddressEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a specific port that the MLB lists define."
INDEX {mlbPortIndex }
::= { mlbAddressTable 1 }
MlbAddressEntry ::=
SEQUENCE {
mlbPortIndex
Integer32,
mlbBurnAddress
MacAddress,
mlbLocAddress
MacAddress,
mlbActiveAddress
INTEGER
}
mlbPortIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value for each port, equal to the value of ifIndex for the port.
The maximum number of ports for mlb is 2 . "
::= { mlbAddressEntry 1 }
mlbBurnAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the burned-in MacAddress on the LANRANger."
::= { mlbAddressEntry 2 }
mlbLocAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is a locally administered address. If a zero value appears, the network administrator
did not set a locally administered address."
::= { mlbAddressEntry 3 }
mlbActiveAddress OBJECT-TYPE
SYNTAX INTEGER {burnedIn(1), locallyAdministered(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MAC address that is in use on the LANRANger.
The address selected will appear in ifPhysAddress."
::= { mlbAddressEntry 4 }
--NOTIFICATIONS
mlbEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for the MLB."
::= { mlb 0 }
mlbLanTableOverflow NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"The station table has the maximum number of addresses for the LANRANger."
::= { mlbEvents 1 }
mlbStatusChanged NOTIFICATION-TYPE
OBJECTS { agnLed }
STATUS current
DESCRIPTION
"The trap indicates changes in the device status ."
::= { mlbEvents 2 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\cvt.txt
--
--Version: 1.0
--Date: 16.10.94
--By: RADLINX & Orly Nicklass
--File: cvt.txt
--
genSnar OBJECT IDENTIFIER ::= { radConverters 1 }
-- SNAR - SNA conversion software
-- STC, FTC - Token to SDLC conversion devices
-- SEC, FEC - Ether to SDLC conversion devices
-- XTC - X.25/QLLC conversion device
--
-- Definitions apply to all products,
-- unless otherwise specified.
-- The devices are generally referred
-- as 'device'.
--
Sap ::= OCTET STRING (SIZE (1))
SdlcAddr ::= OCTET STRING (SIZE (1))
-- OctetRange ::= Integer32 (1..255)
--Active ::= INTEGER { inactive(1) , active(2) }
--Side ::= INTEGER { sideA(1) , sideB(2) }
--Enable ::= INTEGER { disable(1) , enable(2) }
--** THE SNAR TREE **--
snarState OBJECT IDENTIFIER ::= { genSnar 1 }
snarNva OBJECT IDENTIFIER ::= { genSnar 3 }
snarSna OBJECT IDENTIFIER ::= { genSnar 5 }
--
-- SNAR state group
-- General state information
--
snarStatus OBJECT-TYPE
SYNTAX INTEGER {
up (1),
down (2),
test (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The status of the whole SNAR process
1 -up
2 -down
3 -test (After setting one of the previous states, the
status will be test until the changes will be done).
"
::= { snarState 1 }
snarBufferUsage OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The buffer usage of the SNAR (in percentage).
"
::= { snarState 2 }
snarMaxSnaSession OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Max number of sessions supported in this SNAR implementation
"
::= { snarState 3 }
snarSaveChanges OBJECT-TYPE
SYNTAX INTEGER{
noSave (1),
save (2),
saveAndReset (3),
undoAllChanges (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"N/A to SNAR, only for devices. When changes are made to any
configuration parameters (SNA, NVA or others) it should be
stored in the device's NVRAM and then the device is restarted.
Using this variable the manager can:
2 - Just save into NVRAM all configuration changes
3 - Save into NVRAM the configuration changes and restart the
Device, to reflect the changes.
4 - Undo all changes since last reset or
save, (without resetting the device).
Load the original configuration from the NVRAM.
"
::= { snarState 5 }
--
-- snarNVA group
--
-- Defines the NetView agent configuration and internal
-- statistics, applicable to SNAR and all devices
--
nvaAgentsNumber OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The number of configured NetView agents
"
::= { snarNva 2 }
--*********
nvaAgentTable OBJECT-TYPE
SYNTAX SEQUENCE OF NvaAgentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
"
::= { snarNva 3 }
nvaAgentEntry OBJECT-TYPE
SYNTAX NvaAgentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table nvaAgentTable."
INDEX { nvaAgIndex }
::= { nvaAgentTable 1 }
NvaAgentEntry ::=
SEQUENCE {
nvaAgIndex
Integer32,
nvaAgAdminStatus
INTEGER,
nvaAgOperState
INTEGER,
nvaAgFilter
OCTET STRING,
nvaAgAllowRunCmd
INTEGER,
--****CFG******
nvaAgAccessType
INTEGER,
nvaAgIfIndex
Integer32,
nvaAgXidBlockId
OCTET STRING,
nvaAgXidBlockNum
OCTET STRING,
nvaAgSSap
Sap,
nvaAgDSap
Sap,
nvaAgRemMacAddr
MacAddress,
nvaAgSdlcAddr
SdlcAddr,
nvaAgResourceName
DisplayString
}
nvaAgIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Agent number .
Range (1 - nvaAgentsNumber)
"
::= { nvaAgentEntry 1 }
nvaAgAdminStatus OBJECT-TYPE
SYNTAX INTEGER { disable(1) , enable(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The admin. status of NV AGENT. Value of 'disable'
will prevent the NetView agent from trying to
connect to the NetView management system
"
::= { nvaAgentEntry 3 }
nvaAgOperState OBJECT-TYPE
SYNTAX INTEGER { inactive(1) , active(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Current Operation state of the NetView agent. Active
state means that the NetView agent is in session
with the NetView management system
"
::= { nvaAgentEntry 4 }
nvaAgFilter OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alert filter bit mask. Each bit corresponds to a specific alert
sent by the NetView agent.
"
::= { nvaAgentEntry 5 }
nvaAgAllowRunCmd OBJECT-TYPE
SYNTAX INTEGER { disable(1) , enable(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines whether the NetView agent is allowed to handle
operational commands, received by the RUNCMD facility
"
::= { nvaAgentEntry 6 }
nvaAgAccessType OBJECT-TYPE
SYNTAX INTEGER{
llcCsmacd (1),
llcTokenRing (3),
sdlc (6),
qllcX25 (10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Defines the method in which the agent tries to
connect to the NetView management system(the SNA host)
"
::= { nvaAgentEntry 7 }
nvaAgIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The port number of the interface in which the
NetView agent connects to the SNA host
"
::= { nvaAgentEntry 8 }
nvaAgXidBlockId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The BLOCKID part of the XID information which the NetView agent
should use to connect to the NetView management system
(The SNA host)
"
::= { nvaAgentEntry 9 }
nvaAgXidBlockNum OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (3))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The BLOCKNUM part of the XID information which the NetView agent
should use to connect to the NetView management system
(The SNA host)
"
::= { nvaAgentEntry 10 }
nvaAgSSap OBJECT-TYPE
SYNTAX Sap
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Local SAP, used for the NetView session - for LLC
access type session only.
"
::= { nvaAgentEntry 11 }
nvaAgDSap OBJECT-TYPE
SYNTAX Sap
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Remote(host) Sap used by the NetView agent for the
SNA host connection - for LLC access session type
only.
"
::= { nvaAgentEntry 12 }
nvaAgRemMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Remote(host) MAC address used by the NetView agent
for the SNA host connection - for LLC access session
type only.
"
::= { nvaAgentEntry 13 }
nvaAgSdlcAddr OBJECT-TYPE
SYNTAX SdlcAddr
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" SDLC address used by the NetView agent for the SNA
host connection - for SDLC access session type only.
"
::= { nvaAgentEntry 14 }
nvaAgResourceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" A 4 character name that is appended to the resource
name in the NetView alerts sent by the NetView agent
"
::= { nvaAgentEntry 15 }
nvaAgentStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF NvaAgentStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
"
::= { snarNva 4 }
nvaAgentStatEntry OBJECT-TYPE
SYNTAX NvaAgentStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table nvaAgentStatTable."
INDEX { nvaAgStatIndex }
::= { nvaAgentStatTable 1 }
NvaAgentStatEntry ::=
SEQUENCE {
nvaAgStatIndex
Integer32,
--*****STATISTICS****
nvaAgStatTime
TimeTicks,
nvaAgActPu
Counter32,
nvaAgDactPu
Counter32,
nvaAgRpNmvt
Counter32,
nvaAgRnNmvt
Counter32,
nvaAgSpNmvt
Counter32,
nvaAgSAlerts
Counter32,
nvaAgRRunCmd
Counter32,
nvaAgSRunCmd
Counter32,
nvaAgSPdstat
Counter32
}
nvaAgStatIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Agent number .
Range (1 - nvaAgentsNumber)
"
::= { nvaAgentStatEntry 1 }
nvaAgStatTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Time since last reset of the NV agent statistics.
Setting to a value of 0 will clear all Agents'
statistics.
"
::= { nvaAgentStatEntry 2 }
nvaAgActPu OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Number of session initiation (ACTPU) requests received from
the SNA host
"
::= { nvaAgentStatEntry 3 }
nvaAgDactPu OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Number of session disconnection (DACTPU) requests received
from the SNA host
"
::= { nvaAgentStatEntry 4 }
nvaAgRpNmvt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Number of NMVTs received from the SNA host, and responded
with a positive response.
"
::= { nvaAgentStatEntry 5 }
nvaAgRnNmvt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Number of NMVTs received from the SNA host, and
respond with a negative response.
"
::= { nvaAgentStatEntry 6 }
nvaAgSpNmvt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Number of NMVTs (of any type) sent to the SNA host.
"
::= { nvaAgentStatEntry 7 }
nvaAgSAlerts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Number of alert NMVTs sent by the NetView agent.
"
::= { nvaAgentStatEntry 9 }
nvaAgRRunCmd OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Number of RUNCMD (execute-command NMVTs) received by the
NetView agent.
"
::= { nvaAgentStatEntry 10 }
nvaAgSRunCmd OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of RUNCMD replies sent to the NetView host.
"
::= { nvaAgentStatEntry 11 }
nvaAgSPdstat OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of PDSTAT NMVTs sent by the NetView agent.
"
::= { nvaAgentStatEntry 12 }
--
-- snaSNA group
--
-- Defines the sessions' parameters to be converted
--
--*********
snaSessTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnaSessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Holding SNA session's parameters for each side of a
specific session, indexed by session_id
"
::= { snarSna 3 }
snaSessEntry OBJECT-TYPE
SYNTAX SnaSessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table snaSessTable."
INDEX { sessIfIndex, sessId, sessSide }
::= { snaSessTable 1 }
SnaSessEntry ::=
SEQUENCE {
sessIfIndex
Integer32,
sessId
Integer32,
sessSide
INTEGER,
sessDev
Integer32,
sessAdminStatus
INTEGER,
sessOperState
INTEGER,
sessAccessType
INTEGER,
sessSXidBlockId
OCTET STRING,
sessSXidBlockNum
OCTET STRING,
--** LLC/SDLC **
sessSSap
Sap,
sessDSap
Sap,
sessRemMacAddr
MacAddress,
--** SDLC **
sessSdlcAddr
SdlcAddr,
sessGroupPoll
SdlcAddr,
sessRole
INTEGER,
--** LLC/IP **
sessIpEncapsulated
INTEGER,
sessDestIpAddr
IpAddress,
--** QLLC x25 **
sessRemX25Addr
OCTET STRING
}
sessIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interface used by this SNA session
"
::= { snaSessEntry 1 }
sessId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The unique identifier of the converted SNA session id
"
::= { snaSessEntry 2 }
sessSide OBJECT-TYPE
SYNTAX INTEGER { sideA(1) , sideB(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The SNA session side. Each session handled by SNAR/device,
creates 2 SNA sessions, hereafter called 'side A' and 'side B'
Configuration parameters, and Statistics are defined for each
side separately.
"
::= { snaSessEntry 3 }
sessDev OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The device number, used in devices setup. N/A to SNAR.
"
::= { snaSessEntry 4 }
sessAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2),
underCreation (3),
stop (4),
start (5),
invalid (10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Admin. status of this session, as requested by the manager.
10 - Session is invalid, and not handled by SNAR
devices.
1 - Session is disabled. SNAR/Device will not try to start
this session.
2- Session is enabled. SNAR/Device will try to start this
session.
3- Under_creation - This session parameters are under creation,
manipulated by a manager.
4 - stop: stop an enabled session immediately - no need
to save change.
5 - start :start a stopped sessions immediately - no need to
save change.
"
::= { snaSessEntry 5 }
sessOperState OBJECT-TYPE
SYNTAX INTEGER {
stopped (1),
disabled (2),
sdlcProb03 (3),
llcProb04 (4),
ifProb30 (30),
ifProb80 (80),
ifProb81 (81),
ifProb87 (87),
ifProb88 (88),
ok (99)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Current operating state.
See Manual reference for more information.
"
::= { snaSessEntry 6 }
sessAccessType OBJECT-TYPE
SYNTAX INTEGER{
llcCsmacd (1),
llcTokenRing (3),
sdlc (6),
qllcX25 (10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The access type used by this side of the converted
session.
"
::= { snaSessEntry 7 }
sessSXidBlockId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The BLOCKID part of the XID information sent by this side for the
SNA session initiation
"
::= { snaSessEntry 8 }
sessSXidBlockNum OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (3))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The BLOCKNUM part of the XID information sent by this side for the
SNA session initiation
"
::= { snaSessEntry 9 }
sessSSap OBJECT-TYPE
SYNTAX Sap
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Local SAP used by SNAR for this session's side (LLC
sessions only)
"
::= { snaSessEntry 10 }
sessDSap OBJECT-TYPE
SYNTAX Sap
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The remote SAP used by SNAR for this session's side
(LLC sessions only)
"
::= { snaSessEntry 11 }
sessRemMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The remote MAC address used by this session's side
(LLC sessions only)
"
::= { snaSessEntry 12 }
sessSdlcAddr OBJECT-TYPE
SYNTAX SdlcAddr
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SDLC address used by this session's side
(SDLC sessions only, both primary and secondary)
"
::= { snaSessEntry 13 }
sessGroupPoll OBJECT-TYPE
SYNTAX SdlcAddr
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The address of the group poll in which this session's side
participates (SLDC secondary only).
A value of 0 indicates that it doesn't participate
in any group. Only one group is supported for each
SDLC line (same port)
"
::= { snaSessEntry 14 }
sessRole OBJECT-TYPE
SYNTAX INTEGER{
primary (1),
secondary (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of SDLC session for this side.
"
::= { snaSessEntry 15 }
sessIpEncapsulated OBJECT-TYPE
SYNTAX INTEGER { disable(1) , enable(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specified whether this session data is encapsulated within
UDP/IP
"
::= { snaSessEntry 16 }
sessDestIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination IP address (IP encapsulated sessions only).
"
::= { snaSessEntry 17 }
sessRemX25Addr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The remote X25 address (QLLC only) .
"
::= { snaSessEntry 18 }
--*********
snaSessTuneTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnaSessTuneEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Holding SNA session parameters for each side of a
specific session, indexed by session_id
"
::= { snarSna 4 }
snaSessTuneEntry OBJECT-TYPE
SYNTAX SnaSessTuneEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table snaSessTuneTable."
INDEX { sessTuneIfIndex, sessTuneId, sessTuneSide}
::= { snaSessTuneTable 1 }
SnaSessTuneEntry ::=
SEQUENCE {
sessTuneIfIndex
Integer32,
sessTuneId
Integer32,
sessTuneSide
INTEGER,
--** TUNNING **
sessBufferSize
Integer32,
sessSegmentation
INTEGER,
sessFirstSide
INTEGER,
sessWindow
Integer32,
sessDuplex
INTEGER,
sessRXidBlockId
OCTET STRING,
sessRXidBlockNum
OCTET STRING,
sessCheckXid
INTEGER,
sessT1
Integer32,
sessTi
Integer32,
sessT2
Integer32,
sessN2
Integer32,
sessUdpPort
Integer32
}
sessTuneIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The SNA session side.
"
::= { snaSessTuneEntry 1 }
sessTuneId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The unique identifier of the converted SNA session.
"
::= { snaSessTuneEntry 2 }
sessTuneSide OBJECT-TYPE
SYNTAX INTEGER { sideA(1) , sideB(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The SNA session's side.
"
::= { snaSessTuneEntry 3 }
sessBufferSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The max. buffer size of remote device (All sessions).
"
::= { snaSessTuneEntry 4 }
sessSegmentation OBJECT-TYPE
SYNTAX INTEGER { disable(1) , enable(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Specifies whether the SNAR should perform
segmentation when incoming frame on one side is
longer then the sessSideBufferSize of the other size
1 - disable - don't perform segmentation
2 - enable - perform segmentation
"
::= { snaSessTuneEntry 5 }
sessFirstSide OBJECT-TYPE
SYNTAX INTEGER { sideA(1) , sideB(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies which side of the two SNA sides (side_a or side_b)
should be started first (SNAR only, N/A to devices)
"
::= { snaSessTuneEntry 6 }
sessWindow OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The max window size (1 .. 127) for this session's side.
"
::= { snaSessTuneEntry 7 }
sessDuplex OBJECT-TYPE
SYNTAX INTEGER{
half (1),
full (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Specifies the type of SDLC device on the other end
of the SDLC line. FULL- means a device capable of
transmit and receive data simultaneously.
"
::= { snaSessTuneEntry 8 }
sessRXidBlockId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The BLOCKID part of the XID information expected to be received
on this side of the SNA session
"
::= { snaSessTuneEntry 9 }
sessRXidBlockNum OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (3))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The BLOCKNUM part of the XID information expected to be received
on this side of the SNA session
"
::= { snaSessTuneEntry 10 }
sessCheckXid OBJECT-TYPE
SYNTAX INTEGER { disable(1) , enable(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specified whether the received XID information should
be checked and compared to the value of sessRXid:
1 - disable: don't check
2 - enable : check
"
::= { snaSessTuneEntry 11 }
sessT1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The T1 timer (in 100 msec) for this session's side.
"
::= { snaSessTuneEntry 12 }
sessTi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The Ti timer (in sec) for this session
"
::= { snaSessTuneEntry 13 }
sessT2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The T2 timer (in 100 msec) for this session
"
::= { snaSessTuneEntry 14 }
sessN2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The N2 value for this session's side
"
::= { snaSessTuneEntry 15 }
sessUdpPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The UDP port used by SNAR (IP encapsulated
sessions only)
"
::= { snaSessTuneEntry 16 }
--*********
snaSessStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnaSessStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Holding SNA session parameters for each side of a
specific session, indexed by session_id
"
::= { snarSna 5 }
snaSessStatEntry OBJECT-TYPE
SYNTAX SnaSessStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table snaSessStatTable."
INDEX { sessStatIfIndex, sessStatId, sessStatSide }
::= { snaSessStatTable 1 }
SnaSessStatEntry ::=
SEQUENCE {
sessStatIfIndex
Integer32,
sessStatId
Integer32,
sessStatSide
INTEGER,
--** STATISTICS **
sessStatTime
TimeTicks,
sessSPius
Counter32,
sessSBytes
Counter32,
sessRPius
Counter32,
sessRBytes
Counter32,
sessSessFailure
Counter32,
sessXidDenieds
Counter32
}
sessStatIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" "
::= { snaSessStatEntry 1 }
sessStatId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The unique identifier of the converted SNA session.
"
::= { snaSessStatEntry 2 }
sessStatSide OBJECT-TYPE
SYNTAX INTEGER { sideA(1) , sideB(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The SNA session's side.
"
::= { snaSessStatEntry 3 }
sessStatTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Time since last reset of this session statistics.
Setting to a value of 0 will clear all session
statistics.
"
::= { snaSessStatEntry 4 }
sessSPius OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The number of PIUs sent by this session's side
"
::= { snaSessStatEntry 5 }
sessSBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The number of bytes sent by this session's side.
"
::= { snaSessStatEntry 6 }
sessRPius OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The number of PIUs received by this session
"
::= { snaSessStatEntry 7 }
sessRBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The number of bytes received by this session's side.
"
::= { snaSessStatEntry 8 }
sessSessFailure OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The number of session failures occurs to this
session's side.
"
::= { snaSessStatEntry 9 }
sessXidDenieds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The number of XID denied by this session's side
"
::= { snaSessStatEntry 10 }
snaSessQllcTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnaSessQllcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Holding SNA session parameters for each side of a
specific session, indexed by session_id
"
::= { snarSna 7 }
snaSessQllcEntry OBJECT-TYPE
SYNTAX SnaSessQllcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table snaSessQllcTable."
INDEX { sessQllcIfIndex, sessQllcId, sessQllcSide }
::= { snaSessQllcTable 1 }
SnaSessQllcEntry ::=
SEQUENCE {
sessQllcIfIndex
Integer32,
sessQllcId
Integer32,
sessQllcSide
INTEGER,
--***QLLC PARAM
sessInCalls
INTEGER,
sessOutCalls
INTEGER,
sessPVC
INTEGER,
sessCallReqData
OCTET STRING,
sessConnReqFacility
OCTET STRING,
sessGroupId
OCTET STRING,
sessDtePswd
OCTET STRING,
sessDteId
OCTET STRING,
sessMaxInPktSize
Integer32,
sessMaxOutPktSize
Integer32,
sessCallIndReverse
OCTET STRING
}
sessQllcIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
"
::= { snaSessQllcEntry 1 }
sessQllcId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The unique identifier of the converted SNA session.
"
::= { snaSessQllcEntry 2 }
sessQllcSide OBJECT-TYPE
SYNTAX INTEGER { sideA(1) , sideB(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The SNA session's side.
"
::= { snaSessQllcEntry 3 }
sessInCalls OBJECT-TYPE
SYNTAX INTEGER { disable(1) , enable(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"N/Allowed to accept call indicators (QLLC only)
1- disable: don't allow to accept call indications
2- enable: Allow to accept call indications
"
::= { snaSessQllcEntry 4 }
sessOutCalls OBJECT-TYPE
SYNTAX INTEGER { disable(1) , enable(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" N/Allowed to initiate call requests (QLLC only)
1- disable: don't allow to initiate call requests
2- enable: Allow to initiate call requests
"
::= { snaSessQllcEntry 5 }
sessPVC OBJECT-TYPE
SYNTAX INTEGER { disable(1) , enable(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" PVC being used or not (QLLC only)
1 - disable :not use
2 - enable :use
"
::= { snaSessQllcEntry 6 }
sessCallReqData OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The user's data for call requests (QLLC only).
"
::= { snaSessQllcEntry 7 }
sessConnReqFacility OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The facilities for connection requests (QLLC only).
"
::= { snaSessQllcEntry 8 }
sessGroupId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The facility group id (QLLC only)
"
::= { snaSessQllcEntry 9 }
sessDtePswd OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The password for local DTE (QLLC only)
"
::= { snaSessQllcEntry 10}
sessDteId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The identification for local DTE (QLLC only).
"
::= { snaSessQllcEntry 11 }
sessMaxInPktSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The max inbound packet size (QLLC only).
"
::= { snaSessQllcEntry 12 }
sessMaxOutPktSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The max outbound packet size (QLLC only).
"
::= { snaSessQllcEntry 13 }
sessCallIndReverse OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" "
::= { snaSessQllcEntry 14 }
--
--
cvtIfn OBJECT IDENTIFIER ::= {radConverters 2 }
cvtSdlc OBJECT IDENTIFIER ::= {cvtIfn 1 }
--****************************
--**** SDLC GROUP **********
--****************************
sdlcLinesNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
"
::= { cvtSdlc 1 }
sdlcTable OBJECT-TYPE
SYNTAX SEQUENCE OF SdlcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
"
::= { cvtSdlc 3 }
sdlcEntry OBJECT-TYPE
SYNTAX SdlcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table sdlcTable."
INDEX { sdlcIfIndex }
::= { sdlcTable 1 }
SdlcEntry ::=
SEQUENCE {
sdlcIfIndex
Integer32,
sdlcNrz
INTEGER,
sdlcDuplex
INTEGER,
sdlcClockType
INTEGER,
sdlcSpeed
Integer32,
sdlcConnectorType
DisplayString,
sdlcRts
INTEGER
}
sdlcIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the
interface for which this entry
contains management information. The
value of this object for a particular
interface has the same value as the
ifIndex object, defined in [4,6],
for the same interface."
::= { sdlcEntry 1 }
sdlcNrz OBJECT-TYPE
SYNTAX INTEGER { nrz(1), nrzi(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { sdlcEntry 2 }
sdlcDuplex OBJECT-TYPE
SYNTAX INTEGER { half(1), full(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { sdlcEntry 3 }
sdlcClockType OBJECT-TYPE
SYNTAX INTEGER { external(1), internal(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { sdlcEntry 4 }
sdlcSpeed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { sdlcEntry 5 }
sdlcConnectorType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
"
::= { sdlcEntry 6 }
sdlcRts OBJECT-TYPE
SYNTAX INTEGER { constatnt(1), controled(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
"
::= { sdlcEntry 7 }
--**************
sdlcStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF SdlcStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
"
::= { cvtSdlc 4 }
sdlcStatEntry OBJECT-TYPE
SYNTAX SdlcStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table sdlcStatTable."
INDEX { sdlcStatIfIndex }
::= { sdlcStatTable 1 }
SdlcStatEntry ::=
SEQUENCE {
sdlcStatIfIndex
Integer32,
sdlcTimeSinceReset
TimeTicks,
sdlcStatFramesTrans
Counter32,
sdlcStatBytesTrans
Counter32,
sdlcStatFramesRcv
Counter32,
sdlcStatBytesRcv
Counter32,
sdlcStatFramesAbort
Counter32,
sdlcStatFramesBad
Counter32,
sdlcStatFramesCrc
Counter32
}
sdlcStatIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the
interface for which this entry
contains management information. The
value of this object for a particular
interface has the same value as the
ifIndex object, defined in [4,6],
for the same interface."
::= { sdlcStatEntry 1 }
sdlcTimeSinceReset OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The time laps since the last reset statistics.
Setting the object to 0 will reset all line statistics.
"
::= { sdlcStatEntry 2 }
sdlcStatFramesTrans OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
"
::= { sdlcStatEntry 3 }
sdlcStatBytesTrans OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
"
::= { sdlcStatEntry 4 }
sdlcStatFramesRcv OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
"
::= { sdlcStatEntry 5 }
sdlcStatBytesRcv OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
"
::= { sdlcStatEntry 6 }
sdlcStatFramesAbort OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
"
::= { sdlcStatEntry 7 }
sdlcStatFramesBad OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" This counter holds the number of all bad frames.
"
::= { sdlcStatEntry 8 }
sdlcStatFramesCrc OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
"
::= { sdlcStatEntry 9 }
-- LAN Token Ring interface
-- Private MIB - dot5 / TR interface unit
cvtDot5 OBJECT IDENTIFIER ::= { cvtIfn 2 }
cvtDot5Table OBJECT-TYPE
SYNTAX SEQUENCE OF CvtDot5Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains Token Ring interface
parameters and state variables. One entry
per 802.3 interface."
::= { cvtDot5 1 }
cvtDot5Entry OBJECT-TYPE
SYNTAX CvtDot5Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table cvtDot5Table."
INDEX { cvtDot5IfIndex }
::= { cvtDot5Table 1 }
CvtDot5Entry
::= SEQUENCE {
cvtDot5IfIndex
Integer32,
cvtDot5MacAddr
MacAddress,
cvtDot5Commands
INTEGER,
cvtDot5RingSpeed
INTEGER,
cvtDot5ActMonParticipate
INTEGER,
cvtDot5Functional
MacAddress
}
cvtDot5IfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the
802.5 interface for which this entry
contains management information. The
value of this object for a particular
interface has the same value as the
ifIndex object, defined in [4,6],
for the same interface."
::= { cvtDot5Entry 1 }
cvtDot5MacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { cvtDot5Entry 2 }
cvtDot5Commands OBJECT-TYPE
SYNTAX INTEGER {
no-op(1),
open(2),
reset(3),
close(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is set to the value of
open(2), the station should go into the
open state.
When this object is set to the value of
of reset(3), the station should perform reset.
When this object is set to the value
of close(4), the station should go into
the stopped state by removing itself
from the ring.
Setting this object to a value of
no-op(1) has no effect.
When read, this object always has a
value of no-op(1)."
::= { cvtDot5Entry 3 }
cvtDot5RingSpeed OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
oneMegabit(2),
fourMegabit(3),
sixteenMegabit(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ring's bandwidth."
::= { cvtDot5Entry 4 }
cvtDot5ActMonParticipate OBJECT-TYPE
SYNTAX INTEGER {
true(1),
false(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If this object has a value of true(1) then
this interface will participate in the
active monitor selection process. If the
value is false(2) then it will not.
Setting this object might not have an
effect until the next time the interface
is opened."
::= { cvtDot5Entry 5 }
cvtDot5Functional OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The bit mask of all TR functional
addresses for which this interface will
accept frames."
::= { cvtDot5Entry 6 }
-- LAN ETHERNET interface
-- Private MIB - dot3 interface unit
cvtDot3 OBJECT IDENTIFIER ::= { cvtIfn 3 }
cvtDot3Table OBJECT-TYPE
SYNTAX SEQUENCE OF CvtDot3Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains ETHERNET interface
parameters and state variables, one entry
per 802.3 interface."
::= { cvtDot3 1 }
cvtDot3Entry OBJECT-TYPE
SYNTAX CvtDot3Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table cvtDot3Table."
INDEX { cvtDot3IfIndex }
::= { cvtDot3Table 1 }
CvtDot3Entry
::= SEQUENCE {
cvtDot3IfIndex
Integer32,
cvtDot3MacAddr
MacAddress,
cvtDot3Commands
INTEGER,
cvtDot3ActMonParticipate
INTEGER,
cvtDot3Functional
MacAddress
}
cvtDot3IfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the
802.3 interface for which this entry
contains management information. The
value of this object for a particular
interface has the same value as the
ifIndex object, defined in [4,6],
for the same interface."
::= { cvtDot3Entry 1 }
cvtDot3MacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { cvtDot3Entry 2 }
cvtDot3Commands OBJECT-TYPE
SYNTAX INTEGER {
no-op(1),
open(2),
reset(3),
close(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is set to the value of
open(2), the station should go into the
open state.
of reset(3), then the station should do
a reset. On a reset, all MIB counters
should retain their values, if possible.
Other side affects are dependent on the
hardware chip set.
When this object is set to the value
of close(4), the station should go into
the stopped state by removing itself
from the ring.
Setting this object to a value of
no-op(1) has no effect.
When read, this object always has a
value of no-op(1)."
::= { cvtDot3Entry 3 }
cvtDot3ActMonParticipate OBJECT-TYPE
SYNTAX INTEGER {
true(1),
false(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If this object has a value of true(1) then
this interface will participate in the
active monitor selection process. If the
value is false(2) then it will not.
Setting this object might not have an
effect until the next time the interface
is opened."
::= { cvtDot3Entry 4 }
cvtDot3Functional OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The bit mask of all Ethernet functional
addresses for which this interface will
accept frames."
::= { cvtDot3Entry 5 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\stkhubgn.txt
--
--Version: 1.0 
--Date: 17.10.94
--By: Orly Nicklass
--File: stkhubgn.txt
--Last update: Smadar Tauber 12.02.96
radStkHubEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for Rad Stackable General products."
::= { radStkHub 0 }
stkHubGen OBJECT IDENTIFIER ::= { radStkHub 1 } -- Rad Stackable General
stkHubGenAgn OBJECT IDENTIFIER ::= { stkHubGen 1 } -- Rad Stackable Agent
-- Stackable Hub's agent general parameters
stkHubAgentResetConfig OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the value to ON(3)is interpreted as a reset command
for the agent NV Ram. When reset process is ended, a trap
will be issued. "
::= { stkHubGenAgn 1 }
stkHubAgentSpecific OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Object identifier of entity containing additional information
regarding this instance."
::= { stkHubGenAgn 2 }
-- Hub's Security parameters
stkHubSecurityTable OBJECT-TYPE
SYNTAX SEQUENCE OF StkHubSecurityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Hub's Security parameters."
::= { stkHubGen 2 }
stkHubSecurityEntry OBJECT-TYPE
SYNTAX StkHubSecurityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table stkHubSecurityTable."
INDEX { stkHubSecID }
::= { stkHubSecurityTable 1 }
StkHubSecurityEntry ::=
SEQUENCE {
stkHubSecID
Integer32,
stkHubSecEnable
INTEGER,
stkHubSecurityPattern
OCTET STRING,
stkHubSecurityMask
OCTET STRING
}
stkHubSecID OBJECT-TYPE
SYNTAX Integer32 (1..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Segment's security unique identification number"
::= { stkHubSecurityEntry 1 }
stkHubSecEnable OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates whether the specific segment's security is active or not"
::= { stkHubSecurityEntry 2 }
stkHubSecurityPattern OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A six-octet(48 bit) pattern: where the masked bits of stkHubSecurityMask
need to match the MAC address of each port within the segment.Value of all
zeros indicates no security."
::= { stkHubSecurityEntry 3 }
stkHubSecurityMask OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mask of the allowed MAC address that can be connected through
the ports within the segment"
::= { stkHubSecurityEntry 4 }
-- Port Security parameters
stkHubPrtSecurityTable OBJECT-TYPE
SYNTAX SEQUENCE OF StkHubPrtSecurityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Port Security parameters."
::= { stkHubGen 3 }
stkHubPrtSecurityEntry OBJECT-TYPE
SYNTAX StkHubPrtSecurityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table stkHubPrtSecurityTable."
INDEX { stkHubModuleID, stkHubPrtID, stkHubPrtSecID }
::= { stkHubPrtSecurityTable 1 }
StkHubPrtSecurityEntry ::=
SEQUENCE {
stkHubModuleID
Integer32,
stkHubPrtID
Integer32,
stkHubPrtSecID
Integer32,
stkHubPrtSecurityEnable
INTEGER,
stkHubPrtSecurityPattern
OCTET STRING,
stkHubPrtSecurityMask
OCTET STRING
}
stkHubModuleID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the module(slot no.)this port is attached to."
::= { stkHubPrtSecurityEntry 1 }
stkHubPrtID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port within its module."
::= { stkHubPrtSecurityEntry 2 }
stkHubPrtSecID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the security of a given port within its module."
::= { stkHubPrtSecurityEntry 3 }
stkHubPrtSecurityEnable OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this attribute determines application of the
port security."
::= { stkHubPrtSecurityEntry 4 }
stkHubPrtSecurityPattern OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A six-octet(48 bit) pattern: where the masked bits of stkHubPortSecurityMask
need to match the MAC address."
::= { stkHubPrtSecurityEntry 5 }
stkHubPrtSecurityMask OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mask of the allowed MAC address that can be connected through
this port. The security of the individual port over writes the
security of the segment where the port belongs to"
::= { stkHubPrtSecurityEntry 6 }
-- Traps are defined using the conventions in RFC 1215 [6].
softErrors NOTIFICATION-TYPE
STATUS current
DESCRIPTION
" This trap is sent when the software errors threshold is
exceeded."
::= { radStkHubEvents 33 }
resetRequired NOTIFICATION-TYPE
OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed}
STATUS current
DESCRIPTION
"This trap indicates that in order to perform the last SET
request, a reset operation of the router/bridge is required.
This occurs when the layer 2 routing algorithm is changed
between SPF and Spanning Tree. The reset can be performed
manually or using the variable radBridgeAction."
::= { radRBHEEvents 10 }
compNotActive NOTIFICATION-TYPE
OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed}
STATUS current
DESCRIPTION
"Compression was enabled but cannot be activated, since
connected device does not support correct compression. "
::= { radRBHEEvents 20 }
noCompression NOTIFICATION-TYPE
OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed}
STATUS current
DESCRIPTION
"Compression card not present."
::= { radRBHEEvents 21 }
errorBackUp NOTIFICATION-TYPE
OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed}
STATUS current
DESCRIPTION
"Automatic switchover to backup link because of excessive
link errors."
::= { radRBHEEvents 22 }
faultBackUp NOTIFICATION-TYPE
OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed}
STATUS current
DESCRIPTION
"Automatic switchover to backup link because of main link
fault."
::= { radRBHEEvents 23 }
mainLinkUp NOTIFICATION-TYPE
OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed}
STATUS current
DESCRIPTION
"Communication returned to main link."
::= { radRBHEEvents 24 }
failedDialUp NOTIFICATION-TYPE
OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed}
STATUS current
DESCRIPTION
"Cannot establish backup dial-up connection."
::= { radRBHEEvents 25 }
extLoopBack NOTIFICATION-TYPE
OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed}
STATUS current
DESCRIPTION
" This trap is sent when Loopback starts on the link. "
::= { radRBHEEvents 29 }
dialUpConnFailed NOTIFICATION-TYPE
OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed }
STATUS current
DESCRIPTION
" This trap is sent when the dialUp connection is terminated
due to a failure."
::= { radRBHEEvents 41 }
dialUpConnEstablished NOTIFICATION-TYPE
OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed }
STATUS current
DESCRIPTION
" This trap is sent when the dialUp connection is established."
::= { radRBHEEvents 42 }
dialUpConnTerminated NOTIFICATION-TYPE
OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed }
STATUS current
DESCRIPTION
" This trap is sent when the dialUp connection is normally
terminated."
::= { radRBHTEvents 43 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\stkhubtr.txt
--
--Title: STK-T-MIB
--Version: 2.0
--Date: 9-aug-94
--By: Orly Nicklass & Rina Nathaniel & Benny Dolnik
--File: STKHUBTR.TXT
--Update: 26-December-95
-- Ring information for the ring the agent is connected to.
stkHubTR OBJECT IDENTIFIER ::= { radStkHub 2 } -- Stackable Token Ring
stkHubTRRing OBJECT IDENTIFIER ::= { stkHubTR 1}
stkHubTRRingCorrelationEnable OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to ON(3), the in-band agent should perform
correlation each time a station enters/leaves the segment."
::= { stkHubTRRing 1 }
stkHubTRRingAutorecEnable OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to ON(3), the in-band agent should perform
autorecovery each time a beacon status is detected."
::= { stkHubTRRing 2 }
stkHubTRRingAutorecResult OBJECT-TYPE
SYNTAX INTEGER {
not-started(1),
started(2),
segment-ok(3),
segment-fixed(4),
segment-closed(5),
failed(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When autorecovery is completed the result will be recorded.
While in process, STARTED will be recorded.Before process, NOT STARTED
will be recorded"
::= { stkHubTRRing 3 }
stkHubTRRingResetStatistics OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the value of this attribute to ON(3) resets all the inband
statistics and error counters."
::= { stkHubTRRing 4 }
stkHubTRRingLineErrCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented when a frame or token is copied or
repeated by any of the stations on the ring, the E bit is zero in the frame
or token and one of the following conditions exists: 1) there is a
non-data bit (J or K bit) between the SD and the ED of the frame or token, or
2) there is an FCS error in the frame."
::= { stkHubTRRing 5 }
stkHubTRRingBurstErrCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented when any of the stations on the ring detects the
absence of transitions for five half-bit timers (burst-five error)."
::= { stkHubTRRing 6 }
stkHubTRRingACFCErrCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented when any of the stations on the ring receives an
AMP or SMP frame in which A is equal to C is equal to 0, and then receives
another SMP frame with A is equal to C is equal to 0 without first receiving an AMP
frame. It denotes a station that cannot set the AC bits properly."
::= { stkHubTRRing 7 }
stkHubTRRingTotErrCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total of the above described errors"
::= { stkHubTRRing 8 }
stkHubTRRingTotErrThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Total Errors Threshold value. A trap indicating Soft Error
will be sent, if the total number of errors during the last 10 seconds,
reached the threshold value. Threshold value = 0 , disables this trap."
::= { stkHubTRRing 9}
stkHubTRRingTotalFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total frames of the Ring."
::= { stkHubTRRing 10 }
stkHubTRRingTotalFramesRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The rate of total frames on the Ring."
::= { stkHubTRRing 11 }
stkHubTRRingTotalOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total octets of the Ring."
::= { stkHubTRRing 12 }
stkHubTRRingOctetsRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current traffic for the last time interval. The traffic is
expressed in percents of the maximum TokenRing traffic ."
::= { stkHubTRRing 13 }
-- Bridge Hub Module table for TR media type
-- Contains general information about the Module
stkHubTRMdl OBJECT IDENTIFIER ::= { stkHubTR 2}
stkHubTRMdlTable OBJECT-TYPE
SYNTAX SEQUENCE OF StkHubTRMdlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Bridge Hub Module table for TR media type
Contains general information about the Module"
::= { stkHubTRMdl 1 }
stkHubTRMdlEntry OBJECT-TYPE
SYNTAX StkHubTRMdlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table stkHubTRMdlTable."
INDEX {stkHubTRMdlID}
::= { stkHubTRMdlTable 1}
StkHubTRMdlEntry ::=
SEQUENCE {
stkHubTRMdlID
Integer32,
stkHubTRMdlType
INTEGER,
stkHubTRMdlReset
INTEGER,
stkHubTRMdlLed
OCTET STRING,
stkHubTRMdlSpeed
INTEGER,
stkHubTRMdlMngState
INTEGER,
stkHubTRMdlAutodisable
INTEGER,
stkHubTRMdlConfigMsg
OCTET STRING
}
stkHubTRMdlID OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the module in stack. Internal module identifier
is always 1 "
::= {stkHubTRMdlEntry 1}
stkHubTRMdlType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
sah16int(2),
sah16ext(3),
empty(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the type of the module connected with specific identifier "
::= {stkHubTRMdlEntry 2 }
stkHubTRMdlReset OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is set to the value of ON(3),
the module performs software reset. Upon completion, a trap will
be issued to the management station and the value
will be set to OFF."
::= {stkHubTRMdlEntry 3}
stkHubTRMdlLed OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the LEDs status in the module . Each led will
be represented by 4 bits where the first 2 bits will specify the
status (NA, OFF, ON, BLINK), and the next two bits
will specify the color (RED, GREEN, YELLOW)"
::= {stkHubTRMdlEntry 4}
stkHubTRMdlSpeed OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
fourMegabit(2),
sixteenMegabit(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Attribute describing the bandwidth of the media as set by the module
switch.
For certain products, if the value of stkHubTRMdlMngState
is 'enabled', then stkHubTRMdlSpeed can be set to the desired
value. Else, it will be read-only, and will show the status
of the jumper set of the main module.
Refer product's manual."
::= { stkHubTRMdlEntry 5}
stkHubTRMdlMngState OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
disabled(2),
enabled (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the status of the Manage switch
as set on the back panel of the main module.
'enabled' - means that management can override setting of
some HW switch/es."
::= {stkHubTRMdlEntry 6 }
stkHubTRMdlAutodisable OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Attribute describing the status of port Autodisable
mechanism, that protects against inserting in Token Ring
adapters at the wrong speed.
For certain products, if the value of stkHubTRMdlMngState
is 'enabled', then stkHubTRMdlAutodisable can be set to
the desired value. Else, it will be read-only, and will
show the status of the jumper set of the main module.
Refer product's manual."
::= {stkHubTRMdlEntry 7 }
stkHubTRMdlConfigMsg OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Full configuration message coded in internal RND application format.
This entry describes module' configuration. "
::= {stkHubTRMdlEntry 8}
-- Bridge Hub port table for TR media type
-- Contains general information about the ports.
stkHubTRPrt OBJECT IDENTIFIER ::= { stkHubTR 3}
stkHubTRPrtTable OBJECT-TYPE
SYNTAX SEQUENCE OF StkHubTRPrtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Bridge Hub port table for TR media type
Contains general information about the ports."
::= { stkHubTRPrt 1 }
stkHubTRPrtEntry OBJECT-TYPE
SYNTAX StkHubTRPrtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table stkHubTRPrtTable."
INDEX { stkHubTRPrtMdlID,
stkHubTRPrtID }
::= { stkHubTRPrtTable 1 }
StkHubTRPrtEntry ::=
SEQUENCE {
stkHubTRPrtMdlID
Integer32,
stkHubTRPrtID
Integer32,
stkHubTRPrtFunctionality
INTEGER,
stkHubTRPrtConnectorType
INTEGER,
stkHubTRPrtAdminCmd
INTEGER,
stkHubTRPrtActiveState
INTEGER,
stkHubTRPrtTrapMaskEnable
INTEGER,
stkHubTRPrtStatus
INTEGER,
stkHubTRPrtCableProtectEnable
INTEGER,
stkHubTRPrtFlipProtectEnable
INTEGER,
stkHubTRPrtMACAddress
MacAddress,
stkHubTRPrtType
INTEGER
}
stkHubTRPrtMdlID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the module this port is attached to."
::= { stkHubTRPrtEntry 1 }
stkHubTRPrtID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port within its module."
::= { stkHubTRPrtEntry 2 }
stkHubTRPrtFunctionality OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ringin(2) ,
ringout(3) ,
satellite(4),
lobe(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the functionality of the port in a Token ring topology"
::= { stkHubTRPrtEntry 3 }
stkHubTRPrtConnectorType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
idc(2),
rj45(3),
srJ45(4),
db9(5),
bnc(6),
fo-st(7),
db25(8)
-- fo-sma(8),
-- fo-fc(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of hardware connector in the port."
::= { stkHubTRPrtEntry 4 }
stkHubTRPrtAdminCmd OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
disable(2),
enable(3),
short(4),
normal(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"By setting this attribute to DISABLE(2) or SHORT(4) the
management station can force this lobe/port-connection to be
removed and block any access to the network via this lobe/port.
It is not mandatory that a certain lobe/port will support all the
enumerated states. The state of the lobe/port is type specific and
indicated within the specific group"
::= { stkHubTRPrtEntry 5 }
stkHubTRPrtActiveState OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3),
standby(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the electrical or optical activity
state of a lobe or the state of a port. Certain values may
not be applicable in some cases"
::= { stkHubTRPrtEntry 6 }
stkHubTRPrtTrapMaskEnable OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this attribute is set to OFF by the management console the
agent starts sending the unmasked traps related to this port.
Otherwise no traps from this port are sent."
::= { stkHubTRPrtEntry 7 }
stkHubTRPrtStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
disabledManual(2),
disabledAutorec(3),
disabledSecurity(4),
disabledAuto(5),
disabledFlip(6),
inserted(7),
bypass(8),
forcedloop(9),
trunkfail(10),
normal(11)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of this lobe/port connection:
DISABLED-(2) to (6) indicates the reason for the disabled state.
INSERTED(7)indicates that the lobe hardware inserts this lobe into
the ring , thus it becomes part of the ring
BYPASSED(8)indicates that the ring bypasses this lobe and the lobe
hardware provides loopback connection towards the station for media
test purposes.
FORCEDLOOP(9) indicates the port is in a loopback state and the
main ring is connected to the backup path.
TRUNKFAIL (10) indicates that the ring connection is broken for a
repeater, converter or a cable protector.
NORMAL(11) indicates the port is in normal condition
It is not mandatory that a certain lobe/port will support all the
enumerated states."
::= { stkHubTRPrtEntry 8 }
stkHubTRPrtCableProtectEnable OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3),
inhibit(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this attribute determines activation of the cable-fault
protection mechanism of TCR and the optical link mechanism of
TFR and TFC ."
::= { stkHubTRPrtEntry 9 }
stkHubTRPrtFlipProtectEnable OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this attribute determines activation of the flipping-lobe
protection mechanism of the port."
::= { stkHubTRPrtEntry 10 }
stkHubTRPrtMACAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The value of this object is the specific MAC address
of this interface which uniquely identifies this Interface
on a ring."
::= { stkHubTRPrtEntry 11 }
stkHubTRPrtType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
tfr(2),
tfc(3),
tcr(4),
tcp(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of the port specific hardware"
::= { stkHubTRPrtEntry 12}
-- TRAPS
--NOTIFICATIONS
stkHubTREvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for Stackable Token Ring."
::= { stkHubTR 0 }
macAddressUpdated NOTIFICATION-TYPE
OBJECTS { stkHubTRPrtMACAddress }
STATUS current
DESCRIPTION
"This trap will be sent upon every change of
MACAddress on a port."
::= { stkHubTREvents 91 }
mdlStatusChanged NOTIFICATION-TYPE
OBJECTS { stkHubTRMdlLed, stkHubTRMdlType }
STATUS current
DESCRIPTION
"This trap is sent each time module status was changed.When a module is
disconnected, the stkHubTRMdlLed status will be 00 (no led) and the
stkHubTRMdlType will be empty(255)."
::= { stkHubTREvents 27 }
ringBeaconing NOTIFICATION-TYPE
OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed }
STATUS current
DESCRIPTION
"This trap is sent when Token Ring LAN is beaconing."
::= { radRBHTEvents 30 }
lanAdapterRemoved NOTIFICATION-TYPE
OBJECTS { trimErrorDesc, trimErrorSeverity, agnLed }
STATUS current
DESCRIPTION
"This trap is sent when Token Ring LAN adapter was removed by LAN
manager."
::= { radRBHTEvents 31 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\stkhubet.txt
--
--Title: STK-E-MIB
-- Version: 1.0
--Date: 9.10.94
--By: Orly Nicklass & Rina Nathaniel & Benny Dolnik
--File: STKHUBET.TXT
--Update: 09.03.95
stkHubET OBJECT IDENTIFIER ::= { radStkHub 3 } -- Stackable Ethernet
-- Bridge Hub Module table for ET media type
-- Contains general information about the Module
stkHubETMdl OBJECT IDENTIFIER ::= { stkHubET 2}
stkHubETMdlTable OBJECT-TYPE
SYNTAX SEQUENCE OF StkHubETMdlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Bridge Hub Module table for ET media type
Contains general information about the Module"
::= { stkHubETMdl 1 }
stkHubETMdlEntry OBJECT-TYPE
SYNTAX StkHubETMdlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table stkHubETMdlTable."
INDEX {stkHubETMdlID}
::= { stkHubETMdlTable 1}
StkHubETMdlEntry ::=
SEQUENCE {
stkHubETMdlID
Integer32,
stkHubETMdlLed
OCTET STRING,
stkHubETMdlReset
INTEGER
}
stkHubETMdlID OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the module in stack. Internal module identifier
is always 1 "
::= {stkHubETMdlEntry 1}
stkHubETMdlLed OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the LEDs status in the module . Each led will
be represented by 4 bits where the first 2 bits will specify the
status (NA, OFF, ON, BLINK), and the next two bits
will specify the color (RED, GREEN, YELLOW)"
::= {stkHubETMdlEntry 2}
stkHubETMdlReset OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
off(2),
hwReset(3),
configReset(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is set to the value of hwReset(3),
the module performs HW reset.
When this object is set to the value of configReset(4),
the module performs Configuration reset.
Upon completion, a trap will
be issued to the management station and the value
will be set to OFF."
::= {stkHubETMdlEntry 3}
-- Traps are defined using the conventions in RFC 1215 [6].
portStatusChanged NOTIFICATION-TYPE
OBJECTS { stkHubETMdlLed, rpMauMediaAvailable,
rptrPortOperStatus }
STATUS current
DESCRIPTION
"This trap is sent each time port status was changed."
::= { radStkHubEvents 26 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\etrptr.txt
--
--Title: ET-RPTR-MIB
--Version: 1.0
--Date: 26-JAN-94
--By: Orly Nicklass
--File: ETRPTR.TXT
--Update: 12-MAR-95
-- Basic Repeater Information
--
-- Configuration, status, and control objects for the overall
-- repeater
--
radEthRptr OBJECT IDENTIFIER ::= { rad 9 } -- Ethernet Repeaters products
etRptrTable OBJECT-TYPE
SYNTAX SEQUENCE OF EtRptrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains repeater data specific to the etRptrIndex."
::= { radEthRptr 1 }
etRptrEntry OBJECT-TYPE
SYNTAX EtRptrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table etRptrTable."
INDEX { etRptrIndex }
::= { etRptrTable 1 }
EtRptrEntry ::=
SEQUENCE {
etRptrIndex
Integer32,
etRptrGroupCapacity
Integer32,
etRptrOperStatus
INTEGER,
etRptrHealthText
DisplayString,
etRptrReset
INTEGER,
etRptrNonDisruptTest
INTEGER,
etRptrTotalPartitionedPorts
Gauge32,
etRptrMdlVector
Integer32,
etRptrMonitorTransmitCollisions
Counter32
}
etRptrIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The Repeater Id, this table data refer to."
::= { etRptrEntry 1 }
etRptrGroupCapacity OBJECT-TYPE
SYNTAX Integer32 (1..1024)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The etRptrGroupCapacity is the number of groups
that can be contained within the repeater. Within
each managed repeater, the groups are uniquely
numbered in the range from 1 to etRptrGroupCapacity.
Some groups may not be present in the repeater, in
which case the actual number of groups present
will be less than etRptrGroupCapacity. The number
of groups present will never be greater than
etRptrGroupCapacity.
Note: In practice, this will generally be the
number of field-replaceable units (i.e., modules,
cards, or boards) that can fit in the physical
repeater enclosure, and the group numbers will
correspond to numbers marked on the physical
enclosure."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.2,
RepeaterGroupCapacity."
::= { etRptrEntry 2 }
etRptrOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- undefined or unknown status
ok(2), -- no known failures
rptrFailure(3), -- repeater-related failure
groupFailure(4), -- group-related failure
portFailure(5), -- port-related failure
generalFailure(6) -- failure, unspecified type
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The etRptrOperStatus object indicates the
operational state of the repeater. The
etRptrHealthText object may be consulted for more
specific information about the state of the
repeater's health.
In the case of multiple kinds of failures (e.g.,
repeater failure and port failure), the value of
this attribute shall reflect the highest priority
failure in the following order, listed highest
priority first:
rptrFailure(3)
groupFailure(4)
portFailure(5)
generalFailure(6)."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.2,
aRepeaterHealthState."
::= { etRptrEntry 3 }
etRptrHealthText OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The health text object is a text string that
provides information relevant to the operational
state of the repeater. Agents may use this string
to provide detailed information on current
failures, including how they were detected, and/or
instructions for problem resolution. The contents
are agent-specific."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.2,
aRepeaterHealthText."
::= { etRptrEntry 4 }
etRptrReset OBJECT-TYPE
SYNTAX INTEGER {
noReset(1),
resetHW(2),
resetConfig(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to reset(2) causes a
transition to the START state of Fig 9-2 in
section 9 [IEEE 802.3 Std].
Setting this object to noReset(1) has no effect.
The agent will always return the value noReset(1)
when this object is read.
After receiving a request to set this variable to
resetHW(2), the agent is allowed to delay the reset
for a short period. For example, the implementor
may choose to delay the reset long enough to allow
the SNMP response to be transmitted. In any
event, the SNMP response must be transmitted.
This action does not reset the management counters
defined in this document nor does it affect the
portAdminStatus parameters. Included in this
action is the execution of a disruptive Self-Test
with the following characteristics: a) The nature
of the tests is not specified. b) The test resets
the repeater but without affecting management
information about the repeater. c) The test does
not inject packets onto any segment. d) Packets
received during the test may or may not be
transferred. e) The test does not interfere with
management functions.
After performing this self-test, the agent will
update the repeater health information (including
etRptrOperStatus and etRptrHealthText), and send a
etRptrHealth trap.
Setting this object to resetConfig(3) will cause
resetting the repeater to its default values."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.3,
acResetRepeater."
::= { etRptrEntry 5 }
etRptrNonDisruptTest OBJECT-TYPE
SYNTAX INTEGER {
noSelfTest(1),
selfTest(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to selfTest(2) causes the
repeater to perform a agent-specific, non-
disruptive self-test that has the following
characteristics: a) The nature of the tests is
not specified. b) The test does not change the
state of the repeater or management information
about the repeater. c) The test does not inject
packets onto any segment. d) The test does not
prevent the relay of any packets. e) The test
does not interfere with management functions.
After performing this test, the agent will update
the repeater health information (including
etRptrOperStatus and etRptrHealthText) and send a
etRptrHealth trap.
Note that this definition allows returning an
'okay' result after doing a trivial test.
Setting this object to noSelfTest(1) has no
effect. The agent will always return the value
noSelfTest(1) when this object is read."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.3,
acExecuteNonDisruptiveSelfTest."
::= { etRptrEntry 6 }
etRptrTotalPartitionedPorts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the total number of ports in
the repeater whose current state meets all three
of the following criteria: etRptrPortOperStatus
does not have the value notPresent(3),
etRptrPortAdminStatus is enabled(1), and
etRptrPortAutoPartitionState is autoPartitioned(2)."
::= { etRptrEntry 7 }
etRptrMdlVector OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object returns a vector mapping the location of the repeater modules
to their corresponding bit position. A bit that is set indicates an existing module "
::= { etRptrEntry 8 }
--
-- Repeater Monitor Information
--
-- Performance monitoring statistics for the repeater
--
etRptrMonitorTransmitCollisions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented every time the
repeater state machine enters the TRANSMIT
COLLISION state from any state other than ONE PORT
LEFT (Ref: Fig 9-2, IEEE 802.3 Std).
The approximate minimum time for rollover of this
counter is 16 hours."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.2,
aTransmitCollisions."
::= { etRptrEntry 9 }
-- Repeater Security Table
etRptrSecTable OBJECT-TYPE
SYNTAX SEQUENCE OF EtRptrSecEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Repeater Security Table"
::= { radEthRptr 2 }
etRptrSecEntry OBJECT-TYPE
SYNTAX EtRptrSecEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table etRptrSecTable."
INDEX {etRptrId, etRptrSecID }
::= { etRptrSecTable 1 }
EtRptrSecEntry ::=
SEQUENCE {
etRptrId
Integer32,
etRptrSecID
Integer32,
etRptrSecEnable
INTEGER,
etRptrSecPattern
OCTET STRING,
etRptrSecMask
OCTET STRING
}
etRptrId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The Repeater Id, this table data refer to."
::= { etRptrSecEntry 1 }
etRptrSecID OBJECT-TYPE
SYNTAX Integer32 (1..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Segment's security unique identification number"
::= { etRptrSecEntry 2 }
etRptrSecEnable OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates whether the specific segment's security is active or not"
::= { etRptrSecEntry 3 }
etRptrSecPattern OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A six-octet(48 bit) pattern: where the masked bits of etRptrSecMask
need to match the MAC address of each port within the segment.Value of all
zeros indicates no security."
::= { etRptrSecEntry 4 }
etRptrSecMask OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mask of the allowed MAC address that can be connected through
the ports within the segment"
::= { etRptrSecEntry 5 }
--NOTIFICATIONS
radEthRptrEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for Ethernet Repeater."
::= { radEthRptr 0 }
etRptrHealth NOTIFICATION-TYPE
OBJECTS { etRptrOperStatus, rptrGroupOperStatus, agnLed }
STATUS current
DESCRIPTION
"The etRptrHealth trap conveys information related
to the operational status of the repeater. This
trap is sent either when the value of
etRptrOperStatus changes, or upon completion of a
non-disruptive test.
See the etRptrOperStatus object for descriptions
of the information that is sent.
The agent must throttle the generation of
consecutive etRptrHealth traps so that there is at
least a five-second gap between traps of this
type. When traps are throttled, they are dropped,
not queued for sending at a future time. (Note
that 'generating' a trap means sending to all
configured recipients.)"
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.4,
hubHealth notification."
::= { radEthRptrEvents 1 }
etRptrResetEvent NOTIFICATION-TYPE
OBJECTS { etRptrOperStatus, etRptrIndex, agnLed }
STATUS current
DESCRIPTION
"The etRptrResetEvent trap conveys information
related to the operational status of the repeater.
This trap is sent on completion of a repeater
reset action. A repeater reset action is defined
as an a transition to the START state of Fig 9-2
in section 9 [IEEE 802.3 Std], when triggered by a
management command (e.g., an SNMP Set on the
etRptrReset object).
The agent must throttle the generation of
consecutive etRptrResetEvent traps so that there is
at least a five-second gap between traps of this
type. When traps are throttled, they are dropped,
not queued for sending at a future time. (Note
that 'generating' a trap means sending to all
configured recipients.)
The etRptrResetEvent trap is not sent when the agent
restarts and sends an SNMP coldStart or warmStart
trap. However, it is recommended that a repeater
agent send the etRptrOperStatus object as an
optional object with its coldStart and warmStart
trap PDUs.
The etRptrOperStatus object must be included in the
varbind list sent with this trap. The agent may
optionally include the etRptrHealthText object as
well."
REFERENCE
"Reference IEEE 802.3 Rptr Mgt, 19.2.3.4, hubReset
notification."
::= { radEthRptrEvents 2 }
etRptrConfig NOTIFICATION-TYPE
OBJECTS { etRptrMdlVector, agnLed }
STATUS current
DESCRIPTION
" This trap is sent upon every change of the
etRptrMdlVector object."
::= { radEthRptrEvents 3 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\mpmx.txt
--
--Title: RAD's WAN PRODUCTS MIB
--Version: 5.45
--Date: 25.01.2006
--By: Shay Harari
--Last Update: 11-Sep-2008 by Liora Gafni
--Some MIB compilers need those two lines:
-- enterprises OBJECT IDENTIFIER ::=
-- { iso org(3) dod(6) internet(1) private(4) 1 }
--systems OBJECT IDENTIFIER ::= { radGen 1}
--agnt OBJECT IDENTIFIER ::= { radGen 2}
--radSysWan OBJECT IDENTIFIER ::= { systems 3 }
-- -----------------------------------------------------------------------------
wanGen OBJECT IDENTIFIER ::= {radWan 1}
muxHub OBJECT IDENTIFIER ::= {radWan 2}
-- ----------------------------------------------------------------------------------------------
chasWanGen OBJECT IDENTIFIER ::= {wanGen 1}
agnWanGen OBJECT IDENTIFIER ::= {wanGen 2}
mdlWanGen OBJECT IDENTIFIER ::= {wanGen 3}
prtWanGen OBJECT IDENTIFIER ::= {wanGen 4}
mapWanGen OBJECT IDENTIFIER ::= {wanGen 5}
diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6}
--diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6} defined RAD-Diverse-IF-MIB
--ethIf OBJECT IDENTIFIER ::= {diverseIfWanGen 1} (see ethif.txt)
--sonetInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 2} (see radsonet.txt)
--ds3Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 3} (see radds3.txt)
--ds1Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 4} (see radds1.txt)
--hdlcMibObjects OBJECT IDENTIFIER ::= {diverseIfWanGen 5} (see radhdlc.txt)
--v51If OBJECT IDENTIFIER ::= {diverseIfWanGen 6} (see v51.txt)
--ip2If OBJECT IDENTIFIER ::= {diverseIfWanGen 7} (see ipmux.txt)
--broadbandIf OBJECT IDENTIFIER ::= {diverseIfWanGen 8} (see bdband.txt)
--r2If OBJECT IDENTIFIER ::= {diverseIfWanGen 9} (see r2.txt)
--adslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 10} (see radadsl.txt)
--sdslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 11} (see radsdsl.txt)
--shdslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 12} (see radshdsl.txt)
--voiceIf OBJECT IDENTIFIER ::= {diverseIfWanGen 13} (see voiceIf.txt)
--gsmInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 14} (see radGsm.txt)
--ds0BundleIf OBJECT IDENTIFIER ::= {diverseIfWanGen 15} (see radds0.txt)
--pdhInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 16} (see radpdh.txt)
--voipWanGen OBJECT IDENTIFIER ::= {wanGen 7} (see voip.txt)
statAgnGen OBJECT IDENTIFIER ::= {agnWanGen 1}
cnfgAgnGen OBJECT IDENTIFIER ::= {agnWanGen 2}
cmprAgnGen OBJECT IDENTIFIER ::= {agnWanGen 3}
alrBuffGen OBJECT IDENTIFIER ::= {agnWanGen 4}
agnFlipDb OBJECT IDENTIFIER ::= {agnWanGen 5}
agnSa OBJECT IDENTIFIER ::= {agnWanGen 6}
agnListDecoding OBJECT IDENTIFIER ::= {agnWanGen 7}
agnSystemDlci OBJECT IDENTIFIER ::= {agnWanGen 8}
agnVoiceSwitching OBJECT IDENTIFIER ::= {agnWanGen 9}
agnSigProfile OBJECT IDENTIFIER ::= {agnWanGen 10}
agnSystemTs OBJECT IDENTIFIER ::= {agnWanGen 11}
systemVoice OBJECT IDENTIFIER ::= {agnWanGen 12}
statMdlGen OBJECT IDENTIFIER ::= {mdlWanGen 1}
cnfgMdlGen OBJECT IDENTIFIER ::= {mdlWanGen 2}
cmprMdlGen OBJECT IDENTIFIER ::= {mdlWanGen 3}
statPrtGen OBJECT IDENTIFIER ::= {prtWanGen 1}
cnfgPrtGen OBJECT IDENTIFIER ::= {prtWanGen 2}
cmprPrtGen OBJECT IDENTIFIER ::= {prtWanGen 3}
--statisPrtGen OBJECT IDENTIFIER ::= {statPrtGen 3} - Statistics of Ports
--prtFrStatis OBJECT IDENTIFIER ::= {statisPrtGen 1}
--prtCrStatis OBJECT IDENTIFIER ::= {statisPrtGen 2}
--prtDlciStatis OBJECT IDENTIFIER ::= {statisPrtGen 3}
--prtT1Statis OBJECT IDENTIFIER ::= {statisPrtGen 4}
agnMux OBJECT IDENTIFIER ::= {muxHub 1}
mdlMux OBJECT IDENTIFIER ::= {muxHub 2}
prtMux OBJECT IDENTIFIER ::= {muxHub 3}
--cnfgMdlMux OBJECT IDENTIFIER ::= {mdlMux 1}
--statMdlMux OBJECT IDENTIFIER ::= {mdlMux 2}
statPrtMux OBJECT IDENTIFIER ::= {prtMux 1}
cnfgPrtMux OBJECT IDENTIFIER ::= {prtMux 2}
statisPrtGen OBJECT IDENTIFIER ::= {statPrtGen 3}
prtFrStatis OBJECT IDENTIFIER ::= {statisPrtGen 1}
prtCrStatis OBJECT IDENTIFIER ::= {statisPrtGen 2}
prtDlciStatis OBJECT IDENTIFIER ::= {statisPrtGen 3}
prtT1Statis OBJECT IDENTIFIER ::= {statisPrtGen 4}
--
--prtSExHsfStatTable OBJECT IDENTIFIER ::= {statPrtMux 6}
--prtIsdnStatusTable OBJECT IDENTIFIER ::= {statPrtMux 16}
--
prtClCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 1}
prtPh1MlCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 2} --MPH1/e1/t1
prtPhPlCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 3} --MPH1,MPH3,MPL6
prtLs2Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 4} --LS2 family
--prtVc2CnfgTable OBJECT IDENTIFIER ::= {cnfgPrtMux 5}
--prtHsfCnfgTable OBJECT IDENTIFIER ::= {cnfgPrtMux 6}
prtHs4Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 7}
prtHsiCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 8}
prtPVc4Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 9}
prtHsrCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 10}
prtMbeCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 11}
prtTreCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 12}
prtLs6Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 13}
prtVc3Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 14}
prtVcPbxCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 15}
prtIsdnCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 16}
prtLogicalCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 17}
prtFrPlusCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 18}
prtMl4Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 19}
prtAcmCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 20}
prtE2Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 21}
prtLanWanCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 22}
--
-- Wan chassis general information
--
chasVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An ASCII string for description and display of the agent chassis version."
::= { chasWanGen 1 }
chasTotalNoOfSlt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the number of physical slots in the
chassis."
::= { chasWanGen 2 }
chasTotalNoOfIoSlt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the total number of physical IO slots
in the chassis, (not all slots hardware should be occupied
and active) ."
::= { chasWanGen 3 }
chasTotalNoOfPsSlt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the number of physical Power Supply
slots in the chassis."
::= { chasWanGen 4 }
chasTotalNoOfClSlt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the number of physical Common Logic slots in the
chassis."
::= { chasWanGen 5 }
--
-- Wan agent status general information
--
agnSDateFormat OBJECT-TYPE
SYNTAX INTEGER
{
ddMMYYYY (1),
mmDDYYYY (2),
yyyyDDMM (3),
yyyyMMDD (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates the date and time format used for the
agnSDateAndTimeCmd and for the alarm history report."
::= { statAgnGen 1 }
agnSDateCmd OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates the current date as it is known by the
agent using its own real-time clock. The format would be as
specified by the agnSDateFormat.
This parameter can be set for time synchronization between
the NMS and the Agent."
::= { statAgnGen 2 }
agnSTimeCmd OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates the current time as it is known by the
agent using its own real-time clock.
This parameter can be set for time synchronization between
the NMS and the Agent."
::= { statAgnGen 3 }
agnSActiveCnfg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the unique identifier of the configuration,
that is currently active and running."
::= { statAgnGen 4 }
-- return 1 (db1) in phase I
agnSEditCnfg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the unique identifier of the
configuration that is currently loaded into the tmp working
space for manipulation and update operations. Value of 255
means no config. is under editing process."
::= { statAgnGen 5 }
-- return 1 (db1) in phase I
agnSLastCnfgFlipTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the Date & Time of the last flip to the
current configuration at the agent."
::= { statAgnGen 6 }
-- return sysUpTime in phase I
agnSLastCnfgFlipCause OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry describes the flip's cause."
::= { statAgnGen 7 }
-- In phase I return two causes:
-- Power up
-- Update Db
agnSEditBy OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
snmp (2),
terCon1 (3),
terCon2 (4),
terInbandCon1 (5),
terInbandCon2 (6),
lcd (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates which MMI application is working on the
edited config.
The editing phase starts at the first modify operation and
ends after an update(load) operation."
::= { statAgnGen 8 }
agnSClkSrc OBJECT-TYPE
SYNTAX INTEGER
{
master (1),
fallback(2),
internal(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the source of the system clock."
::= { statAgnGen 9 }
agnSAlrStatus OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state in the agent level, i.e. lower
level (card/port) alarms not included.
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= { statAgnGen 10 }
agnSAlrStatusAll OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state of the entire agent, i.e.
including card and port alarms status.
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= { statAgnGen 11 }
agnSMaskedAlrStat OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state in the agent level,[ i.e. lower
level (card/port) alarms not included] including Masked
alarms.
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= { statAgnGen 12 }
agnSMaskedAlrStatAll OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state of the entire agent, i.e.
including card and port alarms status,including
Masked alarms.
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= { statAgnGen 13 }
agnSTstStatAll OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"on(3) - when there is at least one test in progress in one
of the agent cards,
otherwise the value will be off(2)."
::= { statAgnGen 14 }
agnSAlrTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnSAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of agent related alarms and indications for alarms at
system level."
::= { statAgnGen 15 }
agnSAlrEntry OBJECT-TYPE
SYNTAX AgnSAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { agnSAlrIdx}
::= { agnSAlrTable 1}
AgnSAlrEntry ::=
SEQUENCE {
agnSAlrIdx Integer32,
agnSAlrCodeDescription DisplayString,
agnSAlrCode Integer32,
agnSAlrSeverity INTEGER,
agnSAlrState INTEGER,
agnSAlrCounter Integer32,
agnSAlrMask INTEGER,
agnSAlrInvert INTEGER
}
agnSAlrIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify an entry in the alarm status table
of the agent."
::= { agnSAlrEntry 1 }
agnSAlrCodeDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is a full text description of the alarm .
The alarm description includes the following information:
alarm code, alarm text, alarm severity, Masked or Inverted
flag and counter."
::= { agnSAlrEntry 2 }
agnSAlrCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A code identifying the alarm of an entry in the alarm status
table at system level."
::= { agnSAlrEntry 3 }
agnSAlrSeverity OBJECT-TYPE
SYNTAX INTEGER
{
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity of the alarm."
::= { agnSAlrEntry 4 }
agnSAlrState OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the alarm."
::= { agnSAlrEntry 5 }
agnSAlrCounter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A counter - how many times the alarm occured since last
clear operation.
ON and OFF Alarm will be counted separately."
::= { agnSAlrEntry 6 }
agnSAlrMask OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm mask : on/off."
::= { agnSAlrEntry 7 }
agnSAlrInvert OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm invert : on/off."
::= { agnSAlrEntry 8 }
agnSClearAlrCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON, enforce a clear operation on
all the agent(general) events. General alarms are alarms
which are not specific to a card or port. The clear
operation will not be applied for masked/inverted alarms."
::= { statAgnGen 16 }
agnSClearAllAlrCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON, enforce a clear operation on
all MUX alarm events at the levels of agent, slots and ports.
The clear operation will not be applied for masked/inverted
alarms."
::= { statAgnGen 17 }
agnSSanityCheckStatus OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
fail (2),
warning (3),
ok (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Upon completion of the Sanity check process on the TmpCnfg
this attribute will be set to:
FAIL(2) - when there is at least one error encountered and
possibly some warnings.
WARNING(3) - when there are only warnings.
otherwise, the value will be OK(4).
The value will be UNKNOWN(1) if changes were made in the
TmpCnfg following the last Sanity check."
::= { statAgnGen 18 }
agnSNoOfSanityCheckErr OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the number of errors/warnings discovered
by the last SanityCheck process."
::= { statAgnGen 19 }
agnSErrListTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnSErrListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of errors and warnings found during Sanity Check
process."
::= { statAgnGen 20 }
agnSErrListEntry OBJECT-TYPE
SYNTAX AgnSErrListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { agnSErrIdx}
::= { agnSErrListTable 1}
AgnSErrListEntry ::=
SEQUENCE {
agnSErrIdx Integer32,
agnSErrDescription DisplayString
}
agnSErrIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique number to identify an entry in the error list table.
The maximum entry value cannot exceed the value of
'agnSNoOfSanityCheckErr'. "
::= { agnSErrListEntry 1}
agnSErrDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is a full text description of the sanity check
error including error code, slot and port numbers related to
the code ."
::= { agnSErrListEntry 2}
agnSMaxNoOfCnfg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum number of configurations that can be defined and
stored in the MUX.
If the mux has a large capacity, the maximum will be limited
to 254."
::= { statAgnGen 21}
-- return 1 (db1) in phase I
agnSCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnSCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains an entry per configuration. It indicates
if the configuration is valid."
::= { statAgnGen 22 }
-- - in phase I only one entry
agnSCnfgEntry OBJECT-TYPE
SYNTAX AgnSCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { agnSEntryIdx}
::= {agnSCnfgTable 1}
AgnSCnfgEntry ::=
SEQUENCE {
agnSEntryIdx Integer32,
agnSEntryIsValid INTEGER
}
agnSEntryIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique number to identify an entry in the configuration table."
::= { agnSCnfgEntry 1}
agnSEntryIsValid OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates whether the specific configuration
is valid in the MUX . Value of NO indicates: no such
configuration in the MUX. "
::= { agnSCnfgEntry 2}
--
-- Wan agent configuration information
--
agnCSanityCheckCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on(3) will initiate the process
of Sanity check on the TmpCnfg. Upon completion the value
will automatically be changed to off(2)."
::= { cnfgAgnGen 1 }
agnCSaveCnfgIdxCmd OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute specifies the Id of the target RealCnfg to
which the TmpCnfg should be transferred. Upon set command the
MUX will initiate the Sanity-Check process first. If
successful, the actual transfer will be performed. If warnings
are detected, the user will have to perform the command again
to confirm the operation. Setting this object a second time
to the same value without performing any change in the database,
will cause the result: agnSSanityCheckStatus = unknown"
::= { cnfgAgnGen 2 }
-- In phase I only the value 1 (Cnfg1) is valid.
agnCLoadCnfgIdxCmd OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute specifies the Id of the source Cnfg to be
loaded into the TmpCnfg. Upon set operation the actual
transfer will be initiated.
The operation is valid only on Valid configurations
(agnSEntryIsValid)"
::= { cnfgAgnGen 3 }
-- In phase I only the value 1 (Cnfg1) is valid.
agnCClkSrcTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCClkSrcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"All the entries of this table are identical (have the same
value) for all the configurations (1..100) except the
TmpCnfg.
The write operation into the Table Objects is valid only
for the TmpCnfg entry."
::= { cnfgAgnGen 4}
agnCClkSrcEntry OBJECT-TYPE
SYNTAX AgnCClkSrcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnCClkCnfgIdx, agnCClkSrcIdx}
::= { agnCClkSrcTable 1}
AgnCClkSrcEntry ::=
SEQUENCE {
agnCClkCnfgIdx Integer32,
agnCClkSrcIdx Integer32,
agnCClkSrcMode INTEGER,
agnCClkSrcSlt INTEGER,
agnCClkSrcPrt Integer32
}
agnCClkCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg(1..100) being
accessed and Idx 255 relates to the TmpCnfg."
::= { agnCClkSrcEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
agnCClkSrcIdx OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index to the table. There are only two entries to this
table.
Index 1 points to the Master clock parameters and Index 2
points to the Fallback clock parameters"
::= { agnCClkSrcEntry 2}
agnCClkSrcMode OBJECT-TYPE
SYNTAX INTEGER
{
internal (1),
rxClk (2),
adaptive (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The source of the nodal timing."
::= { agnCClkSrcEntry 3}
agnCClkSrcSlt OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry is valid only when we are working in rxClk mode.
For an invalid entry, the return value will be '7fff'h."
::= { agnCClkSrcEntry 4}
agnCClkSrcPrt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry is valid only when we are working in rxClk or
adaptive mode.
For an invalid entry, the return value will be '7fff'h.
- For rxClk mode, the values can be:
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
exPrt11 (11) ,
exPrt12 (12) ,
notApplicable (100),
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103) ,
inPrt4 (104)
- For adaptive mode, the value will be the ifIndex of the
selected IP Bundle."
::= { agnCClkSrcEntry 5}
agnCDeleteCnfgIdxCmd OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute will delete the requested DB
from the NVRAM ."
::= { cnfgAgnGen 5 }
agnCDefaultCnfgIdxCmd OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute will define the desired working
configuration when no conditions of the Flip DB Table are
fulfilled and no Net GO command was issued. This command
will be accepted only if the Configuration number exists
(agnSEntryIsValid=yes)."
::= { cnfgAgnGen 6 }
agnCnfgDataTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCnfgDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains data about the agent configurations.
The table will support only data about valid configurations
of the agent."
::= { cnfgAgnGen 7}
agnCnfgDataEntry OBJECT-TYPE
SYNTAX AgnCnfgDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnCnfgIdx}
::= { agnCnfgDataTable 1}
AgnCnfgDataEntry ::=
SEQUENCE {
agnCnfgIdx Integer32,
agnCnfgDesc DisplayString,
agnCnfgUpdDate DisplayString,
agnCnfgUpdTime DisplayString,
agnCnfgUpdMnger IpAddress
}
agnCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the agent' Cnfg the following
objects refer.
255=Temporary Cnfg (Set is done only to this configuration)."
::= { agnCnfgDataEntry 1}
-- Only the values 1..10, 255 are valid.
agnCnfgDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is a description of the Configuration, entered
by user, to enhance Cnfg recognition."
::= { agnCnfgDataEntry 2}
agnCnfgUpdDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the date when last update of this
configuration was performed, as it is known by the
agent using its own real-time clock. The format would be as
specified by the agnSDateFormat.
When update is performed, the agent should save the date."
::= { agnCnfgDataEntry 3 }
agnCnfgUpdTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the time when last update of this
configuration was performed, as it is known by the
agent using its own real-time clock.
When update is performed, the agent should save the time."
::= { agnCnfgDataEntry 4 }
agnCnfgUpdMnger OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the IP Address of the Manager who
performed the last update of this configuration.
When update is performed, the agent should save the
IP Address of the Manager who commanded the update.
That will enable a manager to know if he performed the last
update, or another manager did."
::= { agnCnfgDataEntry 5 }
agnCnfgAlarm OBJECT IDENTIFIER ::= { cnfgAgnGen 8}
agnCnfgAlrFilterWindow OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Window of time, in seconds.
During this Window, the alarms filter is performed.
Same Window for all agent alarms that need filtering.
Upon end of the Window, the state of the alarm is updated
and a new Window starts.
If no alarm needs filtering, this object's value will not be
used."
::= { agnCnfgAlarm 1}
agnCnfgAlrTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCnfgAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table enables the user to set attributes to each alarm.
Setting for a non-existing entry agnCnfgAlrMask,
agnCnfgAlrInvert or agnCnfgAlrFilter to 'yes'(or yesAndSave
for Mask) will add this new entry to the table.
Setting for an existing entry agnCnfgAlrMask/
agnCnfgAlrInvert/agnCnfgAlrFilter (one or more) to 'no'
(noAndSave for Mask) so that ALL these objects' values are
'no' , will delete this entry from the table.
For agnCnfgAlrMask, only if [(last saved value=noAndSave)
AND (new value is 'no' or 'noAndSave')] the object's value
is considered 'no' for deleting the entry.
For some products (like MP, MPH, Vmux2100) the Active Alarms are always
part of the table and cannot be removed even if their Mask/Invert/Filter
are No."
::= { agnCnfgAlarm 2}
agnCnfgAlrEntry OBJECT-TYPE
SYNTAX AgnCnfgAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnCnfgAlrCode, agnCnfgAlrSlot, agnCnfgAlrPort}
::= { agnCnfgAlrTable 1}
AgnCnfgAlrEntry ::=
SEQUENCE {
agnCnfgAlrCode Integer32,
agnCnfgAlrSlot INTEGER,
agnCnfgAlrPort Integer32,
agnCnfgAlrMask INTEGER,
agnCnfgAlrInvert INTEGER,
agnCnfgAlrFilter INTEGER,
agnCnfgAlrFilterSet Integer32,
agnCnfgAlrFilterReset Integer32,
agnCnfgAlrSeverity INTEGER
}
agnCnfgAlrCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm code. The following attributes refer this code."
::= { agnCnfgAlrEntry 1 }
agnCnfgAlrSlot OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
all (200),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm slot. The following attributes apply for the alarm
code and slot selected.
all = the attributes apply to all slots.
notApplicable = the selected alarm is for system level.
For the Vmux2100 Main Board clA (3) is used."
::= { agnCnfgAlrEntry 2 }
agnCnfgAlrPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm port. The following attributes apply for the alarm
code,slot and port selected.
200 = all = the attributes apply to all ports of the selected slot.
When selected Slot is 'all', only 'all' or 'notApplicable' are valid
Port selections.
notApplicable = the selected alarm is for system or card
level.
=255 for MP
=100 for DXC
- For MP:
- valid cards' ports are: exPrt1(1)..exPrt16(16)
inPrt1(101)..inPrt48 (148)
- IP Bundles
- For DXC, the port index will include the Slot, as for all DXC
tables: [(IO Slot+10)&n] ; n=odd for external ports
n=even for internal ports."
::= { agnCnfgAlrEntry 3 }
agnCnfgAlrMask OBJECT-TYPE
SYNTAX INTEGER
{
no (1),
noAndSave (2),
yes (3),
yesAndSave (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An attribute defining the desired Mask state of an alarm .
no - unmask (this command is not saved in agent's common
database)
noAndSave - unmask ; this command is saved in agent's
common database
yes - mask (this command is not saved in agent's
common database)
yesAndSave - mask ; this command is saved in
agent's common database.
Commands that are not saved, will be lost upon power-up or
selected card removal. "
::= { agnCnfgAlrEntry 4 }
agnCnfgAlrInvert OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An attribute defining the desired Invert state of an alarm .
no - not inverted.
yes - inverted. For MP, it is not applicable for alarms
that are currently OFF."
::= { agnCnfgAlrEntry 5 }
agnCnfgAlrFilter OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An attribute defining if Filter is desired for the alarm .
no - no filter.
yes - filter activate.
This filter is activated within a window of time defined by
agnCnfgAlrFilterWindow.
Its purpose is to avoid frequent changes of an alarm between
ON/OFF states."
::= { agnCnfgAlrEntry 6 }
agnCnfgAlrFilterSet OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is a top threshold causing the alarm that passes it,
to be declared Set (ON) at the end of the respective
window of time.
- For alarms defined by default as state alarms (minor,major)
this value will be in [%].
- For alarms defined by default as events, this value will be
an integer meaning how many times this event should appear
at least, during the window in order to be considered ON.
The maximum value will be 255.
This value should be greater than the one of
agnCnfgAlrFilterReset.
Agents that do not support Alarms Filter, will return 0."
::= { agnCnfgAlrEntry 7 }
agnCnfgAlrFilterReset OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is a bottom threshold causing the alarm that does not
pass it, to be declared Reset (ON) at the end of the
respective window of time.
- For alarms defined by default as state alarms (minor,major)
this value will be in [%].
- For alarms defined by default as events, this value will be
an integer meaning how many times this event should appear
at most, during the window, in order to be considered OFF.
This value should be less than the one of
agnCnfgAlrFilterSet.
Agents that do not support Alarms Filter, will return 0."
::= { agnCnfgAlrEntry 8 }
agnCnfgAlrSeverity OBJECT-TYPE
SYNTAX INTEGER
{
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An attribute defining desired severity of an alarm code
per slot/port "
::= { agnCnfgAlrEntry 9 }
agnCnfgAlrReportTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCnfgAlrReportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table enables the user to configure the desired Alarm
Reports according to alarms severity."
::= { agnCnfgAlarm 3}
agnCnfgAlrReportEntry OBJECT-TYPE
SYNTAX AgnCnfgAlrReportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnCnfgAlrReportType}
::= { agnCnfgAlrReportTable 1}
AgnCnfgAlrReportEntry ::=
SEQUENCE {
agnCnfgAlrReportType INTEGER,
agnCnfgAlrStartReportOn INTEGER,
agnCnfgAlrStartReportOff INTEGER
}
agnCnfgAlrReportType OBJECT-TYPE
SYNTAX INTEGER
{
trap (1),
buffer (2),
relay (3), --Relay 1 = R1
alrLedOn (4), --Minor LED
alrLedBlink (5), --Major LED
relay2 (6) --Relay 2 = R2
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm report type.
trap - traps will be sent only for alarms having the
selected On/Off severity or higher.
buffer - only alarms having the selected On/Off severity and
higher, will be reported to the buffer.
relay - relay contact will be activated only for alarms
having the selected On severity or higher.
For products having 2 relays, this is the R1 Relay.
alrLedOn/alrLedBlink - user should select a higher severity
(ReportOn) for alrLedBlink than for alrLedOn
(Blinking Led means a more severe alarm than steady
ON Led).
alrLedOn - MTCL-1 Alarm Led will be ON only when
agnSAlrStatusAll equals the selected severity or
higher, but lower severity than that selected for
'alrLedBlink'.
For products having 2 LEDs, this is the Minor LED.
alrLedBlink - MTCL-1 Alarm Led will Blink only when
agnSAlrStatusAll equals the selected severity or
higher.
For products having 2 LEDs, this is the Major LED.
relay2 - relay 2 contact will be activated only for alarms
having the selected On severity or higher.
This is the R2 Relay."
::= { agnCnfgAlrReportEntry 1 }
agnCnfgAlrStartReportOn OBJECT-TYPE
SYNTAX INTEGER
{
noReport (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the severity from which alarms will
be reported. Alarms having this severity or higher, will be
reported.
This object specifies the report severity only for alarms
that turn to ON state.
noReport - no Report at all (for any severity)."
::= { agnCnfgAlrReportEntry 2 }
agnCnfgAlrStartReportOff OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
noReport (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the severity from which alarms will
be reported. Alarms having this severity or higher, will be
reported.
This object specifies the report severity only for alarms
that turn to OFF state.
notApplicable - for 'relay','alrLedOn','alrLedBlink', 'relay2' report
types, in MP.
noReport - no Report at all (for any severity)."
::= { agnCnfgAlrReportEntry 3 }
agnCOffsetCmd OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
normal (2),
u1 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An object defining special user request.
notApplicable - is RO value for products that do not support this object.
normal - nothing special
u1 - user 1 - for all Voice cards, the DISPLAYED Tx and Rx Levels
will have the following Offsets:
- 2 Wires port: Tx Level: the base value (for 0dBm) = 0
Rx Level: the base value (for 0dBm) = -2
- 4 Wires port: Tx Level: the base value (for 0dBm) = -16
Rx Level: the base value (for 0dBm) = 7
The MIB and application DB will use the values without Offset."
::= { cnfgAgnGen 9 }
--System T1/E1 Ring Table
--
--This table contains all ML ports that participate in a T1/E1 Ring,
--and their ML port pair.
--The table indexes are Cnfg and the Primary card & port
agnCT1E1RingTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCT1E1RingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration of all T1/E1 Ring ML cards and ports.
The write operation into the table objects is valid only
for the TmpCnfg.
A Slot/Port that does not participate in the T1/E1 Ring,
will not exist in this table.
A ML port that exists in this table, cannot exist at the same
time in the IO Redundancy table (sysCRdnTable)."
::= { cnfgAgnGen 10 }
agnCT1E1RingEntry OBJECT-TYPE
SYNTAX AgnCT1E1RingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Entry in table agnCT1E1RingTable"
INDEX { agnCT1E1RingCnfgIdx, agnCT1E1RingPrimeSlot, agnCT1E1RingPrimePort}
::= { agnCT1E1RingTable 1}
AgnCT1E1RingEntry ::=
SEQUENCE {
agnCT1E1RingCnfgIdx Integer32,
agnCT1E1RingPrimeSlot INTEGER,
agnCT1E1RingPrimePort Integer32,
agnCT1E1RingSecSlot INTEGER,
agnCT1E1RingSecPort Integer32,
agnCT1E1RingRecTime Integer32,
agnCT1E1RingRowStatus RowStatus,
agnCT1E1RingWTR Unsigned32,
agnCT1E1RingDualFailDetection INTEGER
}
agnCT1E1RingCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg(1..255) being
accessed ; Idx of 255 relates to the TmpCnfg."
::= { agnCT1E1RingEntry 1 }
agnCT1E1RingPrimeSlot OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot number of the Primary card of the Ring Pair."
::= { agnCT1E1RingEntry 2 }
agnCT1E1RingPrimePort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port number in the Primary Card.
For external ports, the value will be as that of the port in the
card. Example: external-3 -> 3
external-4 -> 4
For internal ports, the value will be 100 + the port in the
card. Example: internal-1 -> 101
internal-4 -> 104 "
::= { agnCT1E1RingEntry 3 }
agnCT1E1RingSecSlot OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The slot number of the Secondary card of the Ring Pair."
::= { agnCT1E1RingEntry 4 }
agnCT1E1RingSecPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The port number in the Secondary Card.
For external ports, the value will be as that of the port in the
card. Example: external-3 -> 3
external-4 -> 4
For internal ports, the value will be 100 + the port in the
card. Example: internal-1 -> 101
internal-4 -> 104 "
::= { agnCT1E1RingEntry 5 }
agnCT1E1RingRecTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"T1/E1 Ring Recovery Time (sec).
Valid Values: 1..99, 65535.
65535=NA."
::= { agnCT1E1RingEntry 6 }
agnCT1E1RingRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter allows NMS to create/delete entries of this table.
The only possible supported RowStatus vaules are
active (1) and destroy (6)."
::= { agnCT1E1RingEntry 7 }
agnCT1E1RingWTR OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"T1/E1 Ring Wait to Restore (sec).
Valid Values: 0..999, 65535.
65535=NA.
When the value <> 65535, the value of agnCT1E1RingRecTime must be 65535."
::= { agnCT1E1RingEntry 8 }
agnCT1E1RingDualFailDetection OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"T1/E1 Ring - Dual Failure Detection enable/disable."
::= { agnCT1E1RingEntry 9 }
agnCMainExitPort OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
eth (2),
e1T1SerialLink (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An object defining the Main Exit Port for the Data of the device.
In the Vmux-120 Device the Data can Exit via one of the 2 existing ports:
1. Ethernet port (2)
2. A port that can be E1 or T1 or a Serial Link (3)."
::= { cnfgAgnGen 11 }
-- Backup Configuration Table for Main Link Module
agnCBuMlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCBuMlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration for Primary, Secondary and Third Link.
These are used for Link Backup."
::= { cnfgAgnGen 12 }
agnCBuMlEntry OBJECT-TYPE
SYNTAX AgnCBuMlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Entry in table agnCBuMlTable"
INDEX { agnCBuMlCnfgIdx, agnCBuMlRole}
::= { agnCBuMlTable 1}
AgnCBuMlEntry ::=
SEQUENCE {
agnCBuMlCnfgIdx Integer32,
agnCBuMlRole INTEGER,
agnCBuMlType INTEGER,
agnCBuMlDefaultGateway IpAddress,
agnCBuMlSubnetMask IpAddress,
agnCBuMlOamFrequency Integer32,
agnCBuMlOamTimeoutCycles Integer32,
agnCBuMlWaitToRestore Unsigned32,
agnCBuMlBfdSessionNum Unsigned32
}
agnCBuMlCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Index of the Configuration database (1..255) being
accessed. Index of 255 relates to the Temporary Configuration."
::= { agnCBuMlEntry 1 }
agnCBuMlRole OBJECT-TYPE
SYNTAX INTEGER
{
primary (2),
secondary (3),
third (4),
fourth (5)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Role of the Link. Primary Link is the Link that should usually work.
If the Primary Link fails, the data will go through the Secondary Link.
If both Primary and Secondary Links fail, the data will go through the Third
Link, provided it is up."
::= { agnCBuMlEntry 2 }
agnCBuMlType OBJECT-TYPE
SYNTAX INTEGER
{
none (2),
e1T1a (3),
e1T1b (4),
eth (5),
ethNetUser (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Type of the Link.
For E1/T1 the Link can be Link A - e1T1a or Link B - e1T1b.
For ETH-NET, eth (5) can be used.
For ETH-NET/USER ethNetUser (6) can be used."
::= { agnCBuMlEntry 3 }
agnCBuMlDefaultGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default Gateway's IP Address."
::= { agnCBuMlEntry 4 }
agnCBuMlSubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Link subnet mask."
::= { agnCBuMlEntry 5 }
agnCBuMlOamFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time in sec. between 2 OAM packets."
::= { agnCBuMlEntry 6 }
agnCBuMlOamTimeoutCycles OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"No. of cycles the Link will send OAM packets without receiving a response
from the remote Link before switching to the Backup Link."
::= { agnCBuMlEntry 7 }
agnCBuMlWaitToRestore OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines traffic recovery time (in milliseconds)
of the link after its recovery.
This object is applicable only when Recovery Mode is revertive."
::= { agnCBuMlEntry 8 }
agnCBuMlBfdSessionNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the BFD (Bidirectional Forwarding Detection) session number of the link.
When no session exists or when N/A, the value will be 0."
::= { agnCBuMlEntry 9 }
agnCQ50Table OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCQ50Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table for the device Q50 parameters.
Q50 is a Signaling protocol used between PBX devices.
It is possible to control the initiation of calls using Q.50.
This is useful for devices when there is a congestion."
::= { cnfgAgnGen 13 }
agnCQ50Entry OBJECT-TYPE
SYNTAX AgnCQ50Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Entry in table agnCQ50Table"
INDEX { agnCQ50CnfgIdx}
::= { agnCQ50Table 1}
AgnCQ50Entry ::=
SEQUENCE {
agnCQ50CnfgIdx Integer32,
agnCQ50StopCallsThresh Integer32,
agnCQ50DiscardPktThresh Integer32,
agnCQ50BlockNewModemVbdCallsThresh Integer32,
agnCQ50BlockNewModemRelayCallsThresh Integer32
}
agnCQ50CnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Index of the Configuration database (1..255) being
accessed. Index of 255 relates to the Temporary Configuration."
::= { agnCQ50Entry 1 }
agnCQ50StopCallsThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Bandwidth Threshold percent (%) above which
new Calls from the PBX will be disabled."
::= { agnCQ50Entry 2 }
agnCQ50DiscardPktThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Bandwidth Threshold percent (%) above which
voice packets will be discarded. Usually, the value selected should be higher
than the value of agnCQ50StopCallsThresh."
::= { agnCQ50Entry 3 }
agnCQ50BlockNewModemVbdCallsThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Modem VBD Calls Threshold percent (%) above which
new modem calls will be rejected."
::= { agnCQ50Entry 4 }
agnCQ50BlockNewModemRelayCallsThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Modem Relay Calls Threshold percent (%) above which
new modem calls will be rejected."
::= { agnCQ50Entry 5 }
--
-- Compressed information.
--
-- Specially for RadView management station
--
agnCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { cmprAgnGen 1 }
agnCmprEntry OBJECT-TYPE
SYNTAX AgnCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { agnCmprTypIdx, agnCmprCnfgIdx ,agnCmprVersion}
::= {agnCmprTable 1}
AgnCmprEntry ::=
SEQUENCE {
agnCmprTypIdx Integer32,
agnCmprCnfgIdx Integer32,
agnCmprVersion Integer32,
agnCmprObj OCTET STRING
}
agnCmprTypIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Type of the Compressed being
referred."
::= { agnCmprEntry 1}
agnCmprCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the configuration to which the
Compressed information is related."
::= { agnCmprEntry 2}
agnCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal format
of the Compressed data"
::= { agnCmprEntry 3}
agnCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { agnCmprEntry 4}
-- Compressed Dlci table in the Agent level
-- The only way of reading this table is by the command 'GET NEXT'
agnDlciCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnDlciCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= {cmprAgnGen 2}
agnDlciCmprEntry OBJECT-TYPE
SYNTAX AgnDlciCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnDlciCmprCnfgIdx,agnDlciCmprVersion,agnDlciCmprDlciIdx}
::= {agnDlciCmprTable 1}
AgnDlciCmprEntry ::=
SEQUENCE {
agnDlciCmprCnfgIdx Integer32,
agnDlciCmprVersion Integer32,
agnDlciCmprDlciIdx Integer32,
agnDlciCmprObj OCTET STRING
}
agnDlciCmprCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the configuration to which the
Compressed information is related."
::= { agnDlciCmprEntry 1}
agnDlciCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal format
of the Compressed data"
::= { agnDlciCmprEntry 2}
agnDlciCmprDlciIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique identifier of the Dlci,
the compressed information relates to.
The values are between 16 - 991."
::= { agnDlciCmprEntry 3}
agnDlciCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { agnDlciCmprEntry 4}
-- Compressed Status Alarm table at the Agent level
-- The only way of reading this table is by the command 'GET NEXT'
agnAlarmsCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnAlarmsCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= {cmprAgnGen 3}
agnAlarmsCmprEntry OBJECT-TYPE
SYNTAX AgnAlarmsCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnAlarmsCmprVersion,agnAlarmsCmprAlarmIdx}
::= {agnAlarmsCmprTable 1}
AgnAlarmsCmprEntry ::=
SEQUENCE {
agnAlarmsCmprVersion Integer32,
agnAlarmsCmprAlarmIdx Integer32,
agnAlarmsCmprObj OCTET STRING
}
agnAlarmsCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal
format of the Compressed data"
::= { agnAlarmsCmprEntry 1}
agnAlarmsCmprAlarmIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify an entry in the alarm status table
of the agent."
::= { agnAlarmsCmprEntry 2}
agnAlarmsCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { agnAlarmsCmprEntry 3}
-- Compressed History Alarms buffer
-- The only way of reading this table is by the command 'GET NEXT'
agnAlrBufCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnAlrBufCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= {cmprAgnGen 4}
agnAlrBufCmprEntry OBJECT-TYPE
SYNTAX AgnAlrBufCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnAlrBufCmprVersion,agnAlrBufCmprAlarmIdx}
::= {agnAlrBufCmprTable 1}
AgnAlrBufCmprEntry ::=
SEQUENCE {
agnAlrBufCmprVersion Integer32,
agnAlrBufCmprAlarmIdx Integer32,
agnAlrBufCmprObj OCTET STRING
}
agnAlrBufCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal format of
the Compressed data"
::= { agnAlrBufCmprEntry 1}
agnAlrBufCmprAlarmIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify an entry in the history alarms
buffer of the agent."
::= { agnAlrBufCmprEntry 2}
agnAlrBufCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { agnAlrBufCmprEntry 3}
-- Compressed Sanity Errors buffer
-- The only way of reading this table is by the command 'GET NEXT'
agnSCmprErrListTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnSCmprErrListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { cmprAgnGen 5 }
agnSCmprErrListEntry OBJECT-TYPE
SYNTAX AgnSCmprErrListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnSCmprErrVersion,agnSCmprErrIdx}
::= { agnSCmprErrListTable 1}
AgnSCmprErrListEntry ::=
SEQUENCE {
agnSCmprErrVersion Integer32,
agnSCmprErrIdx Integer32,
agnSCmprErrObj OCTET STRING
}
agnSCmprErrVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of the compressed data "
::= { agnSCmprErrListEntry 1}
agnSCmprErrIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique number to identify an entry in the errors list table.
The maximum entry value cannot exceed the value of
'agnSNoOfSanityCheckErr'. "
::= { agnSCmprErrListEntry 2}
agnSCmprErrObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is a full text description of the error,
including: error code, slot and port numbers related to the
code ."
::= { agnSCmprErrListEntry 3}
-- New TS Assignment compressed table, per port 01/09/98
-- The only way of reading this table is by the command 'GET NEXT'
agnTsCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnTsCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { cmprAgnGen 6 }
agnTsCmprEntry OBJECT-TYPE
SYNTAX AgnTsCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { agnTsCmprVerIdx, agnTsCmprCnfgIdx , agnTsCmprSlotIdx,
agnTsCmprPortIdx, agnTsCmprPduIdx }
::= {agnTsCmprTable 1}
AgnTsCmprEntry ::=
SEQUENCE {
agnTsCmprVerIdx Integer32,
agnTsCmprCnfgIdx Integer32,
agnTsCmprSlotIdx Integer32,
agnTsCmprPortIdx Integer32,
agnTsCmprPduIdx Integer32,
agnTsCmprData OCTET STRING
}
agnTsCmprVerIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the version of the internal format
of the Compressed data."
::= { agnTsCmprEntry 1}
agnTsCmprCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the configuration to which the
Compressed information is related.
255=temporary configuration.
Set can be performed only to the temporary configuration."
::= { agnTsCmprEntry 2}
agnTsCmprSlotIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Slot to which the
Compressed information is related.
For MP-2100: IO-1..IO-12 = (5).. (16)
For DXC-30 : IO-1..IO-15 = (5).. (19).
NA=255."
::= { agnTsCmprEntry 3}
agnTsCmprPortIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Port within the Slot, to which the
Compressed information is related.
For Port Index see each product's spec."
::= { agnTsCmprEntry 4}
agnTsCmprPduIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the PDU index within the same port.
That provides for the case when one PDU is not sufficient for all TS
Assignment data of the same port."
::= { agnTsCmprEntry 5}
agnTsCmprData OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the compressed information itself. It provides
information about all TSs of a port."
::= { agnTsCmprEntry 6}
-- Extended Compress General Table with 7 indexes - 10/02/99
-- Used for: V5.1 and V5.2 Variant
agnXCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnXCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { cmprAgnGen 7 }
agnXCmprEntry OBJECT-TYPE
SYNTAX AgnXCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnXCmprTypIdx, agnXCmprVersion, agnXCmprIdx3,agnXCmprIdx4,
agnXCmprIdx5, agnXCmprIdx6, agnXCmprIdx7}
::= {agnXCmprTable 1}
AgnXCmprEntry ::=
SEQUENCE {
agnXCmprTypIdx Integer32,
agnXCmprVersion Integer32,
agnXCmprIdx3 Integer32,
agnXCmprIdx4 Integer32,
agnXCmprIdx5 Integer32,
agnXCmprIdx6 Integer32,
agnXCmprIdx7 Integer32,
agnXCmprObj OCTET STRING
}
agnXCmprTypIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Type of the Compressed being
referred.
One of the types is V5.1 Variant data."
::= { agnXCmprEntry 1}
agnXCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal format of
the Compressed data."
::= { agnXCmprEntry 2}
agnXCmprIdx3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"3rd index - can be used for any purpose according to the
agnXCmprTypIdx.
Example: for V5.1 Variant, this attribute indicates the configuration
to which the Compressed information is related.
255=temporary configuration.
Set can be performed only to the temporary configuration."
::= { agnXCmprEntry 3}
agnXCmprIdx4 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"4th index - can be used for any purpose according to the
agnXCmprTypIdx.
Example: for V5.1 Variant,this attribute indicates a unique number of
the slot position where the card is inserted.
Valid values: psA(1),psB(2),clA(3),clB(4),io1(5)..io12(16); notApplicable=255."
::= { agnXCmprEntry 4}
agnXCmprIdx5 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"5th index - can be used for any purpose according to the
agnXCmprTypIdx.
Example: for V5.1 Variant,this attribute indicates a unique identifier
of the port the compressed information relates to.
Valid values: exPrt1 (1) .. exPrt12 (12) ,
inPrt1 (101) .. inPrt48 (148)."
::= { agnXCmprEntry 5}
agnXCmprIdx6 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"6th index - can be used for any purpose according to the
agnXCmprTypIdx.
Example: for V5.1 Variant,this attribute indicates the Variant index.
Valid values are: 0..127, 255 (= temp cnfg).Set can be performed only
to the temporary configuration."
::= { agnXCmprEntry 6}
agnXCmprIdx7 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"7th index - can be used for any purpose according to the
agnXCmprTypIdx.
Example: for V5.1 Variant,this attribute is not needed. Therefore, its
value will be always 255=notApplicable."
::= { agnXCmprEntry 7}
agnXCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { agnXCmprEntry 8}
--
-- Link Mapping Table for internal use
--
agnLinkMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnLinkMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { mapWanGen 1}
agnLinkMapEntry OBJECT-TYPE
SYNTAX AgnLinkMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {mapLinkId}
::= {agnLinkMapTable 1}
AgnLinkMapEntry ::=
SEQUENCE {
mapLinkId Integer32,
mapLinkSltIdx INTEGER,
mapLinkPrtIdx INTEGER,
mapLinkStatus INTEGER
}
mapLinkId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the link"
::= {agnLinkMapEntry 1}
mapLinkSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
noConnect (2),
clA (3),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries clA(3), io6(10)..io12(16) are
not valid."
::= {agnLinkMapEntry 2}
mapLinkPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
exPrt11 (11) ,
exPrt12 (12) ,
noConnect (100) ,
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103) ,
inPrt4 (104) ,
inPrt5 (105) ,
inPrt6 (106) ,
inPrt7 (107) ,
inPrt8 (108) ,
inPrt9 (109) ,
inPrt10 (110) ,
inPrt11 (111) ,
inPrt12 (112)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique port number. "
::= {agnLinkMapEntry 3}
mapLinkStatus OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
down(2),
up(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of the link between the
two muxes"
::= {agnLinkMapEntry 4}
--
-- diverseIfWanGen - diverse NON-DS1 interfaces of WAN products
--
--sonetInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 2} (see radsonet.txt)
--ds3Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 3} (see radds3.txt)
--ds1Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 4} (see radds1.txt)
--hdlcMibObjects OBJECT IDENTIFIER ::= {diverseIfWanGen 5} (see radhdlc.txt)
--ip2If OBJECT IDENTIFIER ::= { diverseIfWanGen 7 } (see ipmux.txt)
--
-- Wan alarm buffer (history) information
--
alrBufTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlrBufEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { alrBuffGen 1 }
alrBufEntry OBJECT-TYPE
SYNTAX AlrBufEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { alrBufIdx }
::= { alrBufTable 1}
AlrBufEntry ::=
SEQUENCE {
alrBufIdx Integer32,
alrBufDescription DisplayString,
alrBufCode Unsigned32,
alrBufSlot INTEGER,
alrBufPort Unsigned32,
alrBufSeverity INTEGER,
alrBufState INTEGER
}
alrBufIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify this
entry"
::= { alrBufEntry 1}
alrBufDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry is a unique text description of the alarm in the
buffer.
The alarm description includes the following information:
alarm code, slot id, card type, channel id ,
alarm text, alarm status, masked flag and event counter"
::= { alrBufEntry 2}
alrBufCode OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A code identifying the alarm of an entry in the alarm buffer
table."
::= { alrBufEntry 3 }
alrBufSlot OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot number this alarm refers to.
When the alarm refers to a system alarm, the value will be 'notApplicable(255)'."
::= { alrBufEntry 4 }
alrBufPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port number this alarm refers to.
If the port number is irrelevant to this alarm (if it is
a system/card level alarm) the value will be 9999."
::= { alrBufEntry 5 }
alrBufSeverity OBJECT-TYPE
SYNTAX INTEGER
{
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity of the alarm."
::= { alrBufEntry 6 }
alrBufState OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the alarm (On/Off)."
::= { alrBufEntry 7 }
alrBufferClearCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON, will enforce a clear
operation on the Alarms Buffer. Upon completion,
the value will automatically change to off(2).
For MP-2100/2200, this command will not really erase
the Alarm Buffer, but is only an ACK of seeing the Buffer.
It marks a pointer of the last entry's alrBufIdx, in order
to allow view of new alarms entered after this pointer
(alrBufIdxUponLastAck)."
::= { alrBuffGen 2 }
alrBufIdxUponLastAck OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the value of alrBufIdx for the
last existing entry of alrBufTable, when alrBufferClearCmd
was last Set to on(3).
That will enable a user to see only Alarms that entered the
alrBufTable after last Set of alrBufferClearCmd, by GetNext
of alrBufDescription with this index."
::= { alrBuffGen 3 }
--
-- Wan Flip Data-Base parameters
--
-- agnCAgendaTable :
--
agnCAgendaTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCAgendaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table devides the week days into categories needed for
DB flip consideration."
::= {agnFlipDb 1}
agnCAgendaEntry OBJECT-TYPE
SYNTAX AgnCAgendaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnCAgendaCnfgIdx, agnCAgendaDayIdx}
::= {agnCAgendaTable 1}
AgnCAgendaEntry ::=
SEQUENCE {
agnCAgendaCnfgIdx INTEGER,
agnCAgendaDayIdx INTEGER,
agnCAgendaDayCategory INTEGER
}
agnCAgendaCnfgIdx OBJECT-TYPE
SYNTAX INTEGER
{
active (1),
temporary (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active or Temporary Agenda Table.
Both configurations can be read but only the Temporary can
be written to."
::= {agnCAgendaEntry 1}
agnCAgendaDayIdx OBJECT-TYPE
SYNTAX INTEGER
{
sunday (1),
monday (2),
tuesday (3),
wednesday (4),
thursday (5),
friday (6),
saturday (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Day of week"
::= {agnCAgendaEntry 2}
agnCAgendaDayCategory OBJECT-TYPE
SYNTAX INTEGER
{
fullWorkday (1),
partialWorkday (2),
weekend (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Category of the Day "
::= {agnCAgendaEntry 3}
-- agnCFlipNetEventsTable :
--
agnCFlipNetEventsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCFlipNetEventsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table holds the Net Events the MUX should trace"
::= {agnFlipDb 2}
agnCFlipNetEventsEntry OBJECT-TYPE
SYNTAX AgnCFlipNetEventsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnCFlipNetEventsCnfgIdx, agnCFlipNetEventIdx}
::= {agnCFlipNetEventsTable 1}
AgnCFlipNetEventsEntry ::=
SEQUENCE {
agnCFlipNetEventsCnfgIdx INTEGER,
agnCFlipNetEventIdx Integer32,
agnCFlipNetEventActive INTEGER,
agnCFlipNetEventType INTEGER,
agnCFlipNetEventNo Integer32,
agnCFlipNetEventSlot INTEGER,
agnCFlipNetEventPort Integer32,
agnCFlipNetEventISD Integer32,
agnCFlipNetEventOSD Integer32,
agnCFlipNetEventDayType INTEGER,
agnCFlipNetEventStartTime DisplayString,
agnCFlipNetEventEndTime DisplayString
}
agnCFlipNetEventsCnfgIdx OBJECT-TYPE
SYNTAX INTEGER
{
active (1),
temporary (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active or Temporary Net Events Table.
Both configurations can be read but only the Temporary can
be written to."
::= {agnCFlipNetEventsEntry 1}
agnCFlipNetEventIdx OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Entry within the table"
::= {agnCFlipNetEventsEntry 2}
agnCFlipNetEventActive OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates if the entry is valid.
In order to Add/Modify parameters of an entry, this object
should be set to Yes.
In order to delete an entry, this object should be Set to No."
::= {agnCFlipNetEventsEntry 3}
agnCFlipNetEventType OBJECT-TYPE
SYNTAX INTEGER
{
time (1),
linkDown (2),
congestion (3) -- MP3000 Only
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Net Event type "
::= {agnCFlipNetEventsEntry 4}
agnCFlipNetEventNo OBJECT-TYPE
SYNTAX Integer32 (1..512)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Net Event No. (Bit Index)"
::= {agnCFlipNetEventsEntry 5}
agnCFlipNetEventSlot OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The slot to which the net event relates .
Not applicable for time event"
::= {agnCFlipNetEventsEntry 6}
agnCFlipNetEventPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port within the relevant slot.
Valid values:
- extPrt1(1)..exPrt16(16)
- notApplicable(100)
- inPrt1(101)..inPrt84(184)"
::= {agnCFlipNetEventsEntry 7}
agnCFlipNetEventISD OBJECT-TYPE
SYNTAX Integer32 (1..999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time in seconds since the Net Event was reported as ON
until it is considered as ON.
Not relevant for time events."
::= {agnCFlipNetEventsEntry 8}
agnCFlipNetEventOSD OBJECT-TYPE
SYNTAX Integer32 (1..999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time in seconds since the net event was reported as OFF
until it is considered as OFF.
Not relevant for time events."
::= {agnCFlipNetEventsEntry 9}
agnCFlipNetEventDayType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
fullWorkday (2),
partialWorkday (3),
weekend (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time event relates to all days defined in this category in
the agnCAgendaTable.
Applicable only for time event"
::= {agnCFlipNetEventsEntry 10}
agnCFlipNetEventStartTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (5))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time event will be activated at this time.
The format is hh:mm."
::= {agnCFlipNetEventsEntry 11}
agnCFlipNetEventEndTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (5))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time event will be deactivated at this time.
The format is hh:mm."
::= {agnCFlipNetEventsEntry 12}
-- agnCFlipTable :
--
agnCFlipTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCFlipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DB Flip Decisions Table"
::= {agnFlipDb 3}
agnCFlipEntry OBJECT-TYPE
SYNTAX AgnCFlipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnCFlipCnfgIdx, agnCFlipIdx}
::= {agnCFlipTable 1}
AgnCFlipEntry ::=
SEQUENCE {
agnCFlipCnfgIdx INTEGER,
agnCFlipIdx Integer32,
agnCFlipActive INTEGER,
agnCFlipLogicalExp DisplayString,
agnCFlipDbNo Integer32,
agnCFlipDiscardDe INTEGER
}
agnCFlipCnfgIdx OBJECT-TYPE
SYNTAX INTEGER
{
active (1),
temporary (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active or Temporary Flip Decisions Table.
Both configurations can be read but only the Temporary can
be written to."
::= {agnCFlipEntry 1}
agnCFlipIdx OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Entry number within the table"
::= {agnCFlipEntry 2}
agnCFlipActive OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates if the entry is valid.
In order to Add/Modify parameters of an entry this object
should be Set to Yes.
In order to delete an entry, this object should be Set to No."
::= {agnCFlipEntry 3}
agnCFlipLogicalExp OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A logical expression composed of events numbers (which were
configured in the 'AgnCFlipNetEvantsTable') and logical operators
('|', '&', '!', '(', ')') between them.
e.g - (1 & !2) | (121 & 230)"
::= {agnCFlipEntry 4}
agnCFlipDbNo OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ID of the required DB "
::= {agnCFlipEntry 5}
agnCFlipDiscardDe OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the Mux should start discarding
all DE. (MP3000 Only)."
::= {agnCFlipEntry 6}
-- Commands concerning the Flip DB
agnFlipDbControls OBJECT IDENTIFIER ::= {agnFlipDb 4}
agnCFlipDbSanityCheckCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on(3) will initiate the process
of Sanity check on the Temp Flip Db and automatically be
changed to off(2)."
::= { agnFlipDbControls 1 }
agnCSaveFlipDbCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on(3) will initiate the process
of Sanity check on the Temp Flip Db and if it is OK, it will
save the Flip Db in the NVRAM, activating the new Flip DB .
If check detects errors, the save will not be performed.
Afterwards, the object's value will change automatically to off(2)."
::= { agnFlipDbControls 2 }
agnCSaveNetCnfgIdxCmd OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute specifies the Id of the target NVRAM Cnfg to
which the TmpCnfg should be transferred. Upon set command the
MUX will initiate the Sanity-Check process first. If
successful, the actual transfer will be performed. If warnings
are detected, the user will have to perform the command again
to confirm the operation. Setting this object a second time
to the same value without performing any change in the database,
will cause the result: agnSSanityCheckStatus = unknown.
This attribute doesn't cause actual Flip."
::= { agnFlipDbControls 3 }
agnCSaveNetFlipDbCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on(3) will save the Temp Flip DB
Into the NVRAM without actual flip."
::= { agnFlipDbControls 4 }
agnCNetGoCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to On will broadcast a 'GO' command
to the network. When a Mux receives a 'GO' command it issues
a delay for 'agnCNetDelay' seconds and then activates
the DB which was pre-defined by one of the commands :
'agnCSaveNetCnfgIdxCmd' or 'agnCSaveNetFlipDbCmd'."
::= { agnFlipDbControls 5 }
agnCNetDelay OBJECT-TYPE
SYNTAX Integer32 (1..999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute determines the period of time in seconds that
takes for a message to be transferred over all the network.
After a 'GO' command the MUX issues a delay of
'agnCNetDelay' before activating the appropriate DB.
The delay will be applied only after performing
agnCSaveFlipDbCmd."
::= { agnFlipDbControls 6 }
agnCNetEventsBcast OBJECT-TYPE
SYNTAX INTEGER
{
disabled(2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines if the Net Events will be Broadcasted to
other Muxes of the Net or not.
disabled - Net Events will NOT be Broadcasted
enabled - Net Events will be Broadcasted.
Default=disabled.
The value will be applied only after performing
agnCSaveFlipDbCmd."
::= { agnFlipDbControls 7 }
agnCNetEventsBcastInterval OBJECT-TYPE
SYNTAX Integer32 (10..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When agnCNetEventsBcast is enabled, this object determines
the interval of time in seconds, between two consecutive
Net Events transferred over the network.
Default=40 sec.
The interval will be applied only after performing
agnCSaveFlipDbCmd."
::= { agnFlipDbControls 8 }
--
-- agnSa = agent Stand-Alone (not HUB) specific objects
--
agnSaSwchStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the status of the switches on the
stand-alone unit.
Each switch is represented by a bit. The status is a sum of
2**n, according to the bits:
bit 0 NMS (LSB)
bit 1 Terminal '1' = forces the DCE to be terminal with
Rate=9600bps, Data bits=8,
Stop bits=1
bit 2 Xray
bit 3 SW-Load '1' = when SW is loaded
bit 4 DBS
Default of all bits=0
When the status of these switches is unknown, the value of
this object is 255."
::= { agnSa 1 }
--Decoding Table: Code vs. Description
agnListDecodingTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnListDecodingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A decoding table . For each type of list, a description is
given for each existing code."
::= { agnListDecoding 1 }
agnListDecodingEntry OBJECT-TYPE
SYNTAX AgnListDecodingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { agnListDecodingType, agnListDecodingCode }
::= { agnListDecodingTable 1}
AgnListDecodingEntry ::=
SEQUENCE {
agnListDecodingType INTEGER,
agnListDecodingCode Integer32,
agnListDecodingDescription DisplayString,
agnListDecodingDefState INTEGER,
agnListDecodingSeverity INTEGER,
agnListDecodingAcmRelaySlt INTEGER,
agnListDecodingAcmRelayPrt INTEGER
}
agnListDecodingType OBJECT-TYPE
SYNTAX INTEGER
{
alr (1),
sanity (2),
counter (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of list the decoding data refers to.
alr - Alarms list
sanity - Sanity Check Error list.
counter - Counter type of ifPerfCounterType "
::= { agnListDecodingEntry 1}
agnListDecodingCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The specific code for which decoding is needed. "
::= { agnListDecodingEntry 2}
agnListDecodingDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description fitting the specific code and type of list
required. "
::= { agnListDecodingEntry 3}
agnListDecodingDefState OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is applicable only for agnListDecodingType=alr.
It reports the default state/severity of each alarm.
User can change the severity of the alarms defined by
this default via the agnListDecodingSeverity object."
::= { agnListDecodingEntry 4}
agnListDecodingSeverity OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only for agnListDecodingType=alr.
It enables the user to select a severity for each alarm.
The severity is set per alarm code (same for all slots/ports
using this code).
event - can be set only for an alarm that is defined by
default as 'event'.
User can change the severity of the alarms defined by
default as minor or major.
The severity of an event may be set to another severity,
but the change will actually happen only if the event
threshold is active and passed the Set/ON condition.
An event alarm that passed the threshold and changed its
severity, will return automatically to event severity when
meeting its Reset/OFF condition."
::= { agnListDecodingEntry 5}
agnListDecodingAcmRelaySlt OBJECT-TYPE
SYNTAX INTEGER
{ none (1),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the ACM slot, desired for outbound relay
(report) for the selected alarm.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
none - when agnListDecodingType=alr AND the selected
alarm should not be reported by an ACM card.
notApplicable - when agnListDecodingType=sanity OR when
[agnListDecodingType=alr and there is no ACM card installed in the Mux]."
::= { agnListDecodingEntry 6}
agnListDecodingAcmRelayPrt OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the ACM port within the slot, desired for outbound relay
(report) for the selected alarm.
notApplicable - when agnListDecodingType=sanity OR when
agnListDecodingAcmRelaySlt=notApplicable."
::= { agnListDecodingEntry 7}
-- Dlci Table from system point of view
agnDlciTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnDlciEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { agnSystemDlci 1}
agnDlciEntry OBJECT-TYPE
SYNTAX AgnDlciEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnDlciCnfgIdx, agnDlciLSltIdx, agnDlciLPrtIdx, agnDlciHIdx,
agnDlciHSltIdx, agnDlciHPrtIdx, agnDlciLIdx }
::= { agnDlciTable 1}
AgnDlciEntry ::=
SEQUENCE {
agnDlciCnfgIdx Integer32,
agnDlciLSltIdx INTEGER,
agnDlciLPrtIdx Integer32,
agnDlciLIdx Integer32,
agnDlciHSltIdx INTEGER,
agnDlciHPrtIdx Integer32,
agnDlciHIdx Integer32,
agnDlciTxBc INTEGER,
agnDlciTxBe INTEGER,
agnDlciRxBc INTEGER,
agnDlciRxBe INTEGER,
agnDlciPriority Integer32,
agnDlciStatus INTEGER,
agnDlciSpoofing INTEGER,
agnDlciFunnelEnable INTEGER,
agnDlciRoutingProtocol INTEGER,
agnDlciRowStatus RowStatus
}
agnDlciCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { agnDlciEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
agnDlciLSltIdx OBJECT-TYPE
SYNTAX INTEGER
{ cl(3),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
vs (254),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted. This is the Source Slot of the DLCI.
vs=Voice Switching
In the ?004 Unit the entries io6(10)..io16) are not valid.
For ISDN BRI ports of MX300/30 units:
io1(5) = isdn1(5) and io2(6) = isdn2(6)
LSlotIdx is defined according one of the following possiblities:
1. LSlotIdx is < HSlotIdx.
2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx.
3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx."
::= { agnDlciEntry 2}
agnDlciLPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique external or internal port number,
including linkSelector or encapsulator. This is the Source Port of the DLCI.
100=noConnect (for voice switching)
LPrtIdx is defined according one of the following possiblities:
1. LSlotIdx is < HSlotIdx.
2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx.
3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx."
::= { agnDlciEntry 3}
agnDlciLIdx OBJECT-TYPE
SYNTAX Integer32 (0..991)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique index for each possible
used DLCI(16..991). This is the Source Side of the DLCI.
0=notApplicable (for voice switching)
LIdx is defined according one of the following possiblities:
1. LSlotIdx is < HSlotIdx.
2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx.
3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx."
::= { agnDlciEntry 4}
agnDlciHSltIdx OBJECT-TYPE
SYNTAX INTEGER
{ cl (3),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position In the Mux
where the DLCI is routed to - Destination Slot.
For ISDN BRI ports of MX300/30 units:
io1(5) = isdn1(5) and io2(6) = isdn2(6)
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= { agnDlciEntry 5}
agnDlciHPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number where the DLCI is
routed to - Destination Port."
::= { agnDlciEntry 6}
agnDlciHIdx OBJECT-TYPE
SYNTAX Integer32 (1..991)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique internal connection DLCI
number where the Source DLCI is routed to - the Destination Side of the DLCI."
::= { agnDlciEntry 7}
agnDlciTxBc OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
txBc5100bps (3),
txBc6400bps (4),
txBc8300bps (5),
txBc9600bps (6),
txBc14400bps (7),
txBc19200bps (8),
txBc28800bps (9),
txBc32000bps (10),
txBc38400bps (11),
txBc48000bps (12),
txBc56000bps (13),
txBc57600bps (14),
txBc64Kbps (15),
txBc128Kbps (16),
txBc192Kbps (17),
txBc256Kbps (18),
txBc320Kbps (19),
txBc384Kbps (20),
txBc448Kbps (21),
txBc512Kbps (22),
txBc768Kbps (23),
txBc896Kbps (24),
txBc1024Kbps (25),
txBc1152Kbps (26),
txBc1280Kbps (27),
txBc1344Kbps (28),
txBc1472Kbps (29),
txBc1600Kbps (30),
txBc1728Kbps (31),
txBc1856Kbps (32),
txBc1920Kbps (33),
txBc1984Kbps (34),
txBc2048Kbps (35),
txBc16000bps (36), -- Added here: No room between (7) and (8).
-- For Mx 30/300
txBc112Kbps (37),
txBc168Kbps (38),
txBc224Kbps (39),
txBc336Kbps (40),
txBc672Kbps (41),
txBc1536Kbps (42),
txBc1792Kbps (43)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute indicates a unique Tx committed bandwidth on
the user transmit line or at the port receive line."
DEFVAL { full }
::= { agnDlciEntry 8}
agnDlciTxBe OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
txBe5100bps (3),
txBe6400bps (4),
txBe8300bps (5),
txBe9600bps (6),
txBe14400bps (7),
txBe19200bps (8),
txBe28800bps (9),
txBe32000bps (10),
txBe38400bps (11),
txBe48000bps (12),
txBe56000bps (13),
txBe57600bps (14),
txBe64Kbps (15),
txBe128Kbps (16),
txBe192Kbps (17),
txBe256Kbps (18),
txBe320Kbps (19),
txBe384Kbps (20),
txBe448Kbps (21),
txBe512Kbps (22),
txBe768Kbps (23),
txBe896Kbps (24),
txBe1024Kbps (25),
txBe1152Kbps (26),
txBe1280Kbps (27),
txBe1344Kbps (28),
txBe1472Kbps (29),
txBe1600Kbps (30),
txBe1728Kbps (31),
txBe1856Kbps (32),
txBe1920Kbps (33),
txBe1984Kbps (34),
txBe2048Kbps (35),
txBe16000bps (36), -- Added here: No room between (7) and (8).
-- For Mx 30/300
txBe112Kbps (37),
txBe168Kbps (38),
txBe224Kbps (39),
txBe336Kbps (40),
txBe672Kbps (41),
txBe1536Kbps (42),
txBe1792Kbps (43)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute indicates a unique Tx excess bandwidth on the
user transmit line or at the port receive line."
DEFVAL { zero }
::= { agnDlciEntry 9}
agnDlciRxBc OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
rxBc5100bps (3),
rxBc6400bps (4),
rxBc8300bps (5),
rxBc9600bps (6),
rxBc14400bps (7),
rxBc19200bps (8),
rxBc28800bps (9),
rxBc32000bps (10),
rxBc38400bps (11),
rxBc48000bps (12),
rxBc56000bps (13),
rxBc57600bps (14),
rxBc64Kbps (15),
rxBc128Kbps (16),
rxBc192Kbps (17),
rxBc256Kbps (18),
rxBc320Kbps (19),
rxBc384Kbps (20),
rxBc448Kbps (21),
rxBc512Kbps (22),
rxBc768Kbps (23),
rxBc896Kbps (24),
rxBc1024Kbps (25),
rxBc1152Kbps (26),
rxBc1280Kbps (27),
rxBc1344Kbps (28),
rxBc1472Kbps (29),
rxBc1600Kbps (30),
rxBc1728Kbps (31),
rxBc1856Kbps (32),
rxBc1920Kbps (33),
rxBc1984Kbps (34),
rxBc2048Kbps (35),
rxBc16000bps (36), -- Added here: No room between (7) and (8).
-- For Mx 30/300
rxBc112Kbps (37),
rxBc168Kbps (38),
rxBc224Kbps (39),
rxBc336Kbps (40),
rxBc672Kbps (41),
rxBc1536Kbps (42),
rxBc1792Kbps (43)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute indicates a unique Rx committed bandwidth on
the user receive line or at the port transmit line."
DEFVAL { full }
::= { agnDlciEntry 10}
agnDlciRxBe OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
rxBe5100bps (3),
rxBe6400bps (4),
rxBe8300bps (5),
rxBe9600bps (6),
rxBe14400bps (7),
rxBe19200bps (8),
rxBe28800bps (9),
rxBe32000bps (10),
rxBe38400bps (11),
rxBe48000bps (12),
rxBe56000bps (13),
rxBe57600bps (14),
rxBe64Kbps (15),
rxBe128Kbps (16),
rxBe192Kbps (17),
rxBe256Kbps (18),
rxBe320Kbps (19),
rxBe384Kbps (20),
rxBe448Kbps (21),
rxBe512Kbps (22),
rxBe768Kbps (23),
rxBe896Kbps (24),
rxBe1024Kbps (25),
rxBe1152Kbps (26),
rxBe1280Kbps (27),
rxBe1344Kbps (28),
rxBe1472Kbps (29),
rxBe1600Kbps (30),
rxBe1728Kbps (31),
rxBe1856Kbps (32),
rxBe1920Kbps (33),
rxBe1984Kbps (34),
rxBe2048Kbps (35),
rxBe16000bps (36), -- Added here: No room between (7) and (8).
-- For Mx 30/300
rxBe112Kbps (37),
rxBe168Kbps (38),
rxBe224Kbps (39),
rxBe336Kbps (40),
rxBe672Kbps (41),
rxBe1536Kbps (42),
rxBe1792Kbps (43)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute indicates a unique Rx excess bandwidth on the
user receive line or at the port transmit line."
DEFVAL { zero }
::= { agnDlciEntry 11}
agnDlciPriority OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute indicates a unique priority of the pcv.
1 is the lowest priority and 7 is the highest priority."
::= { agnDlciEntry 12}
agnDlciStatus OBJECT-TYPE
SYNTAX INTEGER
{
disconnected (1),
connected (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of the pvc. The status is
disconnected(1) when one of the sides is programmed as
not connected"
::= { agnDlciEntry 13}
agnDlciSpoofing OBJECT-TYPE
SYNTAX INTEGER
{ no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object refers to sending of RIP messages:
- yes : RIP messages will be sent ONLY if there is a change in the Net.
- no : RIP messages will be always sent.
This object is relevant only when one side of the DLCI is a CL-NMS interface.
Default=no. "
::= { agnDlciEntry 14}
agnDlciFunnelEnable OBJECT-TYPE
SYNTAX INTEGER
{ disabled (2),
enabled (3),
source (4),
destination (5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object selects Funnel activation:
- disabled: Funnel operation will be disabled.
The agnDlciTxBe and agnDlciTxBc values are not used for funneling.
- enabled : Funnel operation will be enabled both for Source and Destination
of the DLCI. The agnDlciTxBe and agnDlciTxBc values are used
for funneling calculations.
- source: Funnel operation will be enabled only for the Source of the DLCI.
- destination:Funnel operation will be enabled only for the Destination of the DLCI.
This object is relevant only for an encapsulating DLCI.
In case of a Link Selector DLCI, the agnDlciTxBe and agnDlciTxBc
values are used for bandwidth of Link Selector.
Default=disabled. "
::= { agnDlciEntry 15}
agnDlciRoutingProtocol OBJECT-TYPE
SYNTAX INTEGER
{ notApplicable(1),
rip (2),
rip2(3),
none(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is relevant only when one side of the DLCI is a CL-NMS interface.
It defines which Routing Protocol will be used for management via CL-NMS port.
notApplicable will be used for all slots but CL.
rip is a proprietary rip protocol.
Default=rip. "
::= { agnDlciEntry 16}
agnDlciRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute allows to create/delete a row in this table.
For creating a row, the NMS should set
agnRowStatus.255.id2.id3.id4.id5.id6.id7 = active(1).
For destroying a row, the NMS should set:
agnRowStatus.255.id2.id3.id4.id5.id6.id7 = destroy(6).
Only rows with status active(1) are relevant.
The only possible supported RowStatus vaules are
active (1) and destroy (6)."
::= { agnDlciEntry 17}
-- Voice Switching Configuration Support: agnVoiceSwitching group
agnVoiceSwConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnVoiceSwConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MXcess Configuration for Voice Switching."
::= { agnVoiceSwitching 1 }
agnVoiceSwConfEntry OBJECT-TYPE
SYNTAX AgnVoiceSwConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { agnVoiceSwConfIdx }
::= { agnVoiceSwConfTable 1}
AgnVoiceSwConfEntry ::=
SEQUENCE {
agnVoiceSwConfIdx INTEGER,
agnVoiceSwConfZoneId DisplayString,
agnVoiceSwConfNodeId DisplayString,
agnVoiceSwConfNoOfHops Integer32,
agnVoiceSwConfSidt Integer32,
agnVoiceSwConfLidt Integer32,
agnVoiceSwConfDialPlan INTEGER
}
agnVoiceSwConfIdx OBJECT-TYPE
SYNTAX INTEGER { active(1), temporary(255) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active or Temporary Table.
Both configurations can be read but only the Temporary can
be written to."
::= { agnVoiceSwConfEntry 1}
agnVoiceSwConfZoneId OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"1 or 2 digits, (0-9)(1-9)."
::= { agnVoiceSwConfEntry 2}
agnVoiceSwConfNodeId OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..3))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"1, 2 or 3 digits, (1-9),(0-9),(0-9)."
::= { agnVoiceSwConfEntry 3}
agnVoiceSwConfNoOfHops OBJECT-TYPE
SYNTAX Integer32 (0..20)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of hops the frame will go through the net before deciding to discard
the frame (like time-to-live in IP).
0 = notApplicable
Default=20 ."
::= { agnVoiceSwConfEntry 4}
agnVoiceSwConfSidt OBJECT-TYPE
SYNTAX Integer32 (0..30)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SIDT: Short Inter Digit Timeout used as timer (in sec.) between digits
after routing is completed.
The timeout indicates end of dialing and the call can then be setup.
0 = notApplicable
Default=2 sec."
::= { agnVoiceSwConfEntry 5}
agnVoiceSwConfLidt OBJECT-TYPE
SYNTAX Integer32 (0..30)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"LIDT: Long Inter Digit Timeout used as timer between digits before routing
is completed. If no digits were dialed and LIDT expired then the user will get
an error tone and the call will be disconnected.
0 = notApplicable
Default=15 sec."
::= { agnVoiceSwConfEntry 6}
agnVoiceSwConfDialPlan OBJECT-TYPE
SYNTAX INTEGER {
staticDialPlan(2),
staticDialPlanPlus(3),
flexDialPlan(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the Dialing Plan method that will be used in the Voice Switching.
Static Dialing Plan - Routing is defined by the current device Zone and
Node ID in the Network.
Static Dialing Plan Plus - Includes the Static Dialing Plan but contains an
addition of defining the number of dialed digits.
Flexible Dialing Plan - Routing is defined in a flexible form.
In this plan the user can configure the extension number
of a local voice channel, Route a call to a remote
destination and enter the Number of Digits for a specific
dial prefix."
::= { agnVoiceSwConfEntry 7}
agnVoiceSwConfRtTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnVoiceSwConfRtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Routing Table for Voice Switching."
::= { agnVoiceSwitching 2 }
agnVoiceSwConfRtEntry OBJECT-TYPE
SYNTAX AgnVoiceSwConfRtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { agnVoiceSwConfRtDbId, agnVoiceSwConfRtIdx }
::= { agnVoiceSwConfRtTable 1}
AgnVoiceSwConfRtEntry ::=
SEQUENCE {
agnVoiceSwConfRtDbId INTEGER,
agnVoiceSwConfRtIdx Integer32,
agnVoiceSwConfRtDigits DisplayString,
agnVoiceSwConfRtAction INTEGER,
agnVoiceSwConfRtData DisplayString,
agnVoiceSwConfRtSlot INTEGER,
agnVoiceSwConfRtPort Integer32,
agnVoiceSwConfRtDlci Integer32,
agnVoiceSwConfRtRowStatus RowStatus,
agnVoiceSwConfRtMaxCalls Integer32,
agnVoiceSwConfRtPriority Integer32
}
agnVoiceSwConfRtDbId OBJECT-TYPE
SYNTAX INTEGER { active(1), temporary(255) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active or Temporary Table.
Both configurations can be read but only the Temporary can
be written to."
::= { agnVoiceSwConfRtEntry 1 }
agnVoiceSwConfRtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The Index of the row."
::= { agnVoiceSwConfRtEntry 2 }
agnVoiceSwConfRtDigits OBJECT-TYPE
SYNTAX DisplayString ( SIZE(1..7) )
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" Dialed digits: Series of digits 0...9, '*', '#' or '%'.
The '*' and '#' can have many uses according to the user's decision.
For example, they can be used as part of the Dialed Number,
they exist on the phone number panel.
'*' can also be used instead of a series of numbers.
The '%' means any digits (wildcard) and is used without a series of digits.
When the agnVoiceSwConfRtAction is del (7), the series of digits that
are configured via this MIB object will be deleted from the prefix of
the dialed number."
::= { agnVoiceSwConfRtEntry 3 }
agnVoiceSwConfRtAction OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
zone(2),
node(3),
shortDialing(4),
in(5), -- Internal switching
hgr(6), -- Hunt Group
del(7), -- Delete a prefix from the Dialed Number
rep(8), -- Replace a prefix with a given string of digits
pri(9), -- for ISDN
bri(10),-- for ISDN
numDigDP(11), -- Number of Digits user will dial according to Dialing Plan.
route(12), -- Route to a Remote Destination
ext(13) -- Extension to a local voice channel
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" Action that the system should perform for the digits:
agnVoiceSwConfRtDigits.
The action that is allowed depends on the Dialing Plan.
Here is the list of the allowed actions:
For Static Dialing Plan - zone, node, in, shortDialing, hgr, del, rep
For Static Dialing Plan Plus - zone, node, in, shortDialing, hgr, del, rep, numDigDP
For Flexible Dialing Plan - hgr, del, rep, numDigDP, route, ext"
DEFVAL { notApplicable }
::= { agnVoiceSwConfRtEntry 4 }
agnVoiceSwConfRtData OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..7))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" This field is relevant for actions hgr(6), and rep(8), numDigDP(11)
and contains the following information:
For hgr - the number of the Hunt Group.
For rep - the number of digits to be replaced with.
For numDigDP - the number of digits collected before establishing the call.
0 indicates no defined length. In this case SIDT will be used."
-- DEFVAL {"0" }
::= { agnVoiceSwConfRtEntry 5 }
agnVoiceSwConfRtSlot OBJECT-TYPE
SYNTAX INTEGER{
noConnect(2),
cl (3),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" Routing Slot- Relevant for actions zone(2), node(3), shortDialing(4),
route(12), ext(13)."
DEFVAL { noConnect }
::= { agnVoiceSwConfRtEntry 6 }
agnVoiceSwConfRtPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" Routing Port- Relevant for actions zone(2), node(3), shortDialing(4),
route(12), ext(13).
100=noConnect (for non-routing case)."
DEFVAL { 0 }
::= { agnVoiceSwConfRtEntry 7 }
agnVoiceSwConfRtDlci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" Routing DLCI- Relevant for actions zone(2), node(3), shortDialing(4),
route(12), ext(13).
Valid values:
0=notApplicable (for non-routing case).
1, 16..991 "
DEFVAL { 15 }
::= { agnVoiceSwConfRtEntry 8 }
agnVoiceSwConfRtRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" Status of the row for creating/deleting entries in the table.
The only possible supported RowStatus vaules are
active (1), notInService (2), notReady(3), createAndGo(4),
createAndWait(5) and destroy(6)."
::= { agnVoiceSwConfRtEntry 9 }
agnVoiceSwConfRtMaxCalls OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Maximum no. of simultaneous voice calls that are allowed in the direction
defined by the current entry.
Default=0 (No Limit)."
::= { agnVoiceSwConfRtEntry 10}
agnVoiceSwConfRtPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute indicates a unique priority of the Voice Switching Route.
1 is the lowest priority and 7 is the highest priority.
0 means N/A "
::= { agnVoiceSwConfRtEntry 11}
agnVoiceSwConfHGTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnVoiceSwConfHGEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of Hunt Groups."
::= { agnVoiceSwitching 5 }
agnVoiceSwConfHGEntry OBJECT-TYPE
SYNTAX AgnVoiceSwConfHGEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { agnVoiceSwConfHGdbIdx, agnVoiceSwConfHGIdx }
::= { agnVoiceSwConfHGTable 1}
AgnVoiceSwConfHGEntry ::=
SEQUENCE {
agnVoiceSwConfHGdbIdx INTEGER,
agnVoiceSwConfHGIdx Integer32,
agnVoiceSwConfHGConnect INTEGER,
agnVoiceSwConfHGExt Integer32,
agnVoiceSwConfHGExtString SnmpAdminString,
agnVoiceSwConfHGUserParams SnmpAdminString,
agnVoiceSwConfHGStatus INTEGER
}
agnVoiceSwConfHGdbIdx OBJECT-TYPE
SYNTAX INTEGER { active(1), temporary(255) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active or Temporary Table.
Both configurations can be read but only the Temporary can
be written to."
::= { agnVoiceSwConfHGEntry 1}
agnVoiceSwConfHGIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For Vmux-300 devices -
This object represents a combination of
- Hunt Group number and Extension number OR
- Port number and Extension number.
For other devices (e.g. MXcess, MP-2100H) -
There may be up to 10 Hunt Groups per MXcess. That's the
index of the hunt group relevant to this row."
::= { agnVoiceSwConfHGEntry 2}
agnVoiceSwConfHGConnect OBJECT-TYPE
SYNTAX INTEGER { no(2), yes(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the hunt group should be
considered in any of the mux algorithms."
::= { agnVoiceSwConfHGEntry 3}
agnVoiceSwConfHGExt OBJECT-TYPE
SYNTAX Integer32(0..99)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the extension number of the hunt group.
0 is for not valid. The allowed range is 10 - 99."
DEFVAL { 0 }
::= { agnVoiceSwConfHGEntry 4}
agnVoiceSwConfHGExtString OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the extension string of the hunt group.
This string is a combination of digits, * and #."
::= { agnVoiceSwConfHGEntry 5}
agnVoiceSwConfHGUserParams OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the User's parameters."
::= { agnVoiceSwConfHGEntry 6}
agnVoiceSwConfHGStatus OBJECT-TYPE
SYNTAX INTEGER
{
active (1),
notInService (2),
notReady (3),
createAndGo (4),
createAndWait (5),
destroy (6),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables the user to create/delete entries in this table.
Its usage for values (1)..(6) should be identical to RowStatus SYNTAX.
notApplicable(255) - should be used when the table is static
(i.e. whenever create/delete entries is not allowed)."
::= { agnVoiceSwConfHGEntry 7}
--
-- Signaling Profiles for MP-2200 and MP-2100
--
-- Legacy Profile Table
agnSigProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnSigProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"- For products supporting more than one configuration, the write operation
into the Table is valid only to the TmpCnfg entry.
- For products that do not support configurations, the write operation
into the Table will be to agnSigProfileCnfgIdx=1.
The table includes signaling profile parameters for Legacy Profiles."
::= { agnSigProfile 1}
agnSigProfileEntry OBJECT-TYPE
SYNTAX AgnSigProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnSigProfileCnfgIdx, agnSigProfileIdx, agnSigProfileRxTx}
::= { agnSigProfileTable 1}
AgnSigProfileEntry ::=
SEQUENCE {
agnSigProfileCnfgIdx Integer32,
agnSigProfileIdx Integer32,
agnSigProfileRxTx INTEGER,
agnSigProfileABCD OCTET STRING,
agnSigProfileEcanActSignal INTEGER,
agnSigProfileEcanRespDelay Unsigned32
}
agnSigProfileCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg.
For products supporting more than one configuration,the write
operation is valid only to the TmpCnfg.
For Gmux2000 the range limitation (1..255) was discarded
since the Idx is computed as: <IO Card No.> x 1000 + 255."
::= { agnSigProfileEntry 1}
agnSigProfileIdx OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Signaling Profile (1..5).
For MP-104/204, only Profile=1 will exist."
::= { agnSigProfileEntry 2}
agnSigProfileRxTx OBJECT-TYPE
SYNTAX INTEGER
{
rx (1),
tx (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates if the following objects refer to:
Rx or Tx translation.
Rx : ML->IO
Tx : IO->ML .
For MP-104/204, that means:
Rx : Signaling to FXS CH
Tx : Signaling to E1 Link. "
::= { agnSigProfileEntry 3}
agnSigProfileABCD OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For MP-2100/MP-2200 and for MP-104/204 from R2:
This object represents 6 parameters, by 3 Octets :
Busy Code-MSB nibble, - applicable only for Rx translation
Idle Code- nibble, - applicable only for Rx translation
D Bit Code- nibble,
C Bit Code- nibble,
B Bit Code- nibble,
A Bit Code-LSB nibble.
Each of Busy and Idle Code nibble will have the valid values:
0000 .. FFFF.
Each of A,B,C,D Bit Code nibble represents:
0 hex = 0000 = 0
1 hex = 0001 = 1
2 hex = 0010 = A bit
3 hex = 0011 = B bit
4 hex = 0100 = C bit
5 hex = 0101 = D bit
6 hex = 0110 = A bit inverse
7 hex = 0111 = B bit inverse
8 hex = 1000 = C bit inverse
9 hex = 1001 = D bit inverse
A-F hex - not used (invalid values)
For MP-104/204 R1:
This object represents 3 parameters, by 2 Octets :
Bit 1 = Bit A - OFF Hook for Tx ; Ring for Rx (LSB)
Bit 2 = Bit B - OFF Hook for Tx ; Ring for Rx
Bit 3 = Bit C - OFF Hook for Tx ; Ring for Rx
Bit 4 = Bit D - OFF Hook for Tx ; Ring for Rx
Bit 5 = Bit A - ON Hook for Tx ; Idle for Rx
Bit 6 = Bit B - ON Hook for Tx ; Idle for Rx
Bit 7 = Bit C - ON Hook for Tx ; Idle for Rx
Bit 8 = Bit D - ON Hook for Tx ; Idle for Rx
Bit 9 = Bit A - OOS State for both Tx and Rx
Bit 10 = Bit B - OOS State for both Tx and Rx
Bit 11 = Bit C - OOS State for both Tx and Rx
Bit 12 = Bit D - OOS State for both Tx and Rx
Bit 13 = Spare (always 0)
Bit 14 = Spare (always 0)
Bit 15 = Spare (always 0)
Bit 16 = Spare (always 0) (MSB)
When the object is not applicable, the Octet String will have 0 bytes."
::= { agnSigProfileEntry 4}
agnSigProfileEcanActSignal OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
aBit1 (2),
aBit0 (3),
bBit1 (4),
bBit0 (5),
cBit1 (6),
cBit0 (7),
dBit1 (8),
dBit0 (9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Echo Canceller Activation Signal.
This object specifies which BIT (A, B, C, or D) and which value (0 or 1)
will be used for the echo canceller activation. The inverse value will cause the
deactivation of the echo canceller."
::= { agnSigProfileEntry 5}
agnSigProfileEcanRespDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Echo Canceller Response Delay.
This object specifies the response delay in msec for the activation/deactivation
of the echo canceller.
The value should be in multiples of 100 msec: 100, 200, 300, ...2000."
::= { agnSigProfileEntry 6}
-- General Profile Table
agnSigProfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnSigProfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry. This is the general table of signaling profiles."
::= { agnSigProfile 2}
agnSigProfEntry OBJECT-TYPE
SYNTAX AgnSigProfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnSigProfCnfgIdx, agnSigProfIdx}
::= { agnSigProfTable 1}
AgnSigProfEntry ::=
SEQUENCE {
agnSigProfCnfgIdx Integer32,
agnSigProfIdx Integer32,
agnSigProfName DisplayString,
agnSigProfType INTEGER
}
agnSigProfCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg.
The write operation is valid only to the TmpCnfg."
::= { agnSigProfEntry 1}
agnSigProfIdx OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Signaling Profile (1..5)."
::= { agnSigProfEntry 2}
agnSigProfName OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..12))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile Name given by user."
::= { agnSigProfEntry 3 }
agnSigProfType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
legacy (2),
r2Cas (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile Type.
legacy - usual signaling. The parameters for the Legacy Profiles
are detailed in the agnSigProfileTable, above.
r2Cas - R2 signaling. The parameters for the R2 Profiles are detailed
in the r2 ProfileCnfg tables (belong to r2If). "
::= { agnSigProfEntry 4 }
--
-- TS Assignment Table from system point of view
--
-- agnTsTable OBJECT-TYPE ::= { agnSystemTs 1}
--
-- For this table see tsa.txt file.
-- General System Voice parameters
--
systemVoiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF SystemVoiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"General Parameters for voice - system level."
::= { systemVoice 1 }
systemVoiceEntry OBJECT-TYPE
SYNTAX SystemVoiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { systemVoiceConfIdx }
::= { systemVoiceTable 1}
SystemVoiceEntry ::=
SEQUENCE {
systemVoiceConfIdx Integer32,
systemVoiceNationalTone INTEGER,
systemVoicePacketRate Unsigned32,
systemVoiceFaxSupport INTEGER,
systemVoiceFaxRate INTEGER,
systemVoiceModemSupport INTEGER,
systemVoiceCoderAndRate INTEGER,
systemVoiceEchoCanceler INTEGER,
systemVoiceTxGain Integer32,
systemVoiceDtmfRelayMethod INTEGER,
systemVoiceDtmfRelayRxPayloadType Unsigned32,
systemVoiceDtmfRelayPayloadTypeNeg INTEGER,
systemVoiceDtmfRelayTxPayloadType Unsigned32
}
systemVoiceConfIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed - Active or Temporary Configurations.
Idx 255 relates to the temporary TmpCnfg.
All configurations can be read but only the Temporary can
be written to."
::= { systemVoiceEntry 1}
systemVoiceNationalTone OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
usa (2),
australia (3),
brazil (4),
canada (5),
france (6),
germany (7),
israel (8),
mexico (9),
portugal (10),
russia (11),
spain (12),
unitedKingdom (13),
czech (14),
china (15)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tone Characteristics (Amplitude, Frequency, delays etc.).
These characteristics are defined according to the country."
::= { systemVoiceEntry 2}
systemVoicePacketRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the G.729 and G.711 Coders
transmitted Packet Rate in milliseconds."
::= { systemVoiceEntry 3}
systemVoiceFaxSupport OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
faxRelayT38 (3),
vbdPassThrou (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the user to Disable/Enable Fax support."
::= { systemVoiceEntry 4}
systemVoiceFaxRate OBJECT-TYPE
SYNTAX INTEGER
{
notConnected (1),
r4800bps (2),
-- reserved for r7200bps (3)
r9600bps (4),
-- reserved for r12000bps (5)
r14400bps (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Fax Rate limit.
It is irrelevant when Fax support is NA or disabled."
::= { systemVoiceEntry 5}
systemVoiceModemSupport OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
vbdV152 (3),
vbdPassThrou (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the user to Disable/Enable Modem support."
::= { systemVoiceEntry 6}
systemVoiceCoderAndRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
-- reserved for g7231r6300BPS (2)
-- reserved for g7231r5300BPS (3)
-- reserved for g729A8KBPS (4)
g711aLAW (5),
g711uLAW (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Coder and Rate for the Voice Compression."
::= { systemVoiceEntry 7}
systemVoiceEchoCanceler OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Echo Canceler activation."
::= { systemVoiceEntry 8}
systemVoiceTxGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Transmit Gain (volume) in dB."
::= { systemVoiceEntry 9}
systemVoiceDtmfRelayMethod OBJECT-TYPE
SYNTAX INTEGER
{
rfc2833 (1),
sipInfo (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the DTMF Relay Method
that is used to transmit DTMF tones.
rfc2833(1) - inband DTMF relay according to RFC-2833.
sipInfo(2) - out of band DTMF relay using SIP INFO method."
::= { systemVoiceEntry 10}
systemVoiceDtmfRelayRxPayloadType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Rx Payload Type
for DTMF relay RTP packets.
It is relevant only when DTMF Relay Method is RFC-2833."
::= { systemVoiceEntry 11}
systemVoiceDtmfRelayPayloadTypeNeg OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether Payload Type Negotiation is used
(according to RFC-2833) or not.
It is relevant only when DTMF Relay Method is RFC-2833."
::= { systemVoiceEntry 12}
systemVoiceDtmfRelayTxPayloadType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Tx Payload Type
for DTMF relay RTP packets.
It is relevant only when the Payload Type Negotiation is disabled."
::= { systemVoiceEntry 13}
systemVoiceCoderTable OBJECT-TYPE
SYNTAX SEQUENCE OF SystemVoiceCoderEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Voice Coders table."
::= { systemVoice 2 }
systemVoiceCoderEntry OBJECT-TYPE
SYNTAX SystemVoiceCoderEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in Voice Coders table."
INDEX { systemVoiceCoderConfIdx, systemVoiceCoderPriority }
::= { systemVoiceCoderTable 1}
SystemVoiceCoderEntry ::=
SEQUENCE {
systemVoiceCoderConfIdx Unsigned32,
systemVoiceCoderPriority Unsigned32,
systemVoiceCoderCoderAndRate INTEGER
}
systemVoiceCoderConfIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The first index of the table.
This object might represent the Configuration Index (1..100) being accessed;
Index=255 relates to the TmpCnfg.
For devices with multiple configurations, Set is permitted to TmpCnfg(255) only.
Not-Applicable = 1."
::= { systemVoiceCoderEntry 1}
systemVoiceCoderPriority OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Coder's Priority."
::= { systemVoiceCoderEntry 2}
systemVoiceCoderCoderAndRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
g7231r6300BPS (2),
g7231r5300BPS (3),
g729A8KBPS (4),
g711aLAW (5),
g711uLAW (6),
none (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Coder and Rate for the Voice Compression."
::= { systemVoiceCoderEntry 3}
--
-- Wan installed module status general information
--
mdlSInstTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlSInstEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { statMdlGen 1 }
mdlSInstEntry OBJECT-TYPE
SYNTAX MdlSInstEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mdlSInstSltIdx }
::= { mdlSInstTable 1}
MdlSInstEntry ::=
SEQUENCE {
mdlSInstSltIdx INTEGER,
mdlSInstCardType INTEGER,
mdlSHwVersion DisplayString,
mdlSSwVersion DisplayString,
mdlSAlrStatus INTEGER,
mdlSAlrStatusAll INTEGER,
mdlSMaskedAlrStat INTEGER,
mdlSMaskedAlrStatAll INTEGER,
mdlSTstStatusAll INTEGER,
mdlSClearAlrCmd INTEGER,
mdlSClearAllAlrCmd INTEGER,
mdlSTemperature Integer32
}
mdlSInstSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify a slot position in the mux.
In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16)
are not valid.
For the Vmux2100 Main Board clA (3) is used."
::= { mdlSInstEntry 1}
mdlSInstCardType OBJECT-TYPE
SYNTAX INTEGER
{
--
-- General types
--
unknown (1),
empty (2),
-- (3)..(7) are reserved ; they appear in the compress structure
acm (9), --alarm module
--
-- Power Supply Modules
--
ps60W (10),
ps100W (11),
-- (12)..(16) are reserved for the Programmed PS cards
ps (17),
--
-- Cl Modules
--
cl1 (20),
clEth (21),
cl2 (22),
cl2Eth (23),
cl3 (24),
cl3Eth (25),
cl1Clk (26), --CL1 with Station Clock (for LRS102)
--
-- Packet Cards of Megaplex
--
mPh1 (31),
mPh3 (32),
mPh1T1DSU (33),
mPh1T1CSU (34),
mPh1E1DSU (35),
mPh1E1LTU (36),
-- TDM Cards
mtmlFT1 (37),
mtmlFE1 (38),
mtmlH4E1 (39),
mtmlH4E12W (40),
mtmlH4T1 (41),
mtmlH4T12W (42),
mtHsh4E1 (43),
mtHsh4E12W (44),
mtHsh4T1 (45),
mtHsh4T12W (46),
mtmlH2E1 (47),
mtmlH2E12W (48),
mtmlH2T1 (49),
mtmlH2T12W (50),
hsh2E1 (51),
hsh2E12W (52),
hsh2T1 (53),
hsh2T12W (54),
mlIp (55),
mtml4Ip (56),
ml20N1 (57),
ml20N2 (58),
-- Packet Cards of Megaplex
mPl6 (60),
mPl3 (61),
-- VF cards of Megaplex
vf24T1 (62),
vf30E1 (63),
vf48T1 (64),
vf60E1 (65),
-- Vmux-2100 Main Link cards
ml2E1 (68),
ml4E1 (69),
ml2T1 (70),
ml4T1 (71),
mPv4 (72),
--
-- TDM Cards
--
vc16A (73),
vc8EandM (74),
vc8Fxo (75),
vc8Fxs (76),
vc16EandM (77),
vc16Fxo (78),
vc16Fxs (79),
vf3EandM (80),
vf3Fxs (81),
vf3Fxo (82),
vfPbx (83),
vfPbxT1 (84),
vfPbxE1 (85),
mtMlE2S (86), --Single Link
mtMlE2D (87), --Dual Link
mtMlF2T1 (88),
mtMlF2E1 (89),
mtMlT1Fiber (90),
mtMlE1Fiber (91),
mtMlT1FiberFb (92),
mtMlE1FiberFb (93),
mtmlHE1 (94),
mtmlH1E1 (95),
mtmlHSE1 (96),
ml20 (97),
mtMl4T1 (98),
mtMl4E1 (99),
mtMl1T1DSU (100),
mtMl1T1CSU (101),
mtMl1E1DSU (102),
mtMl1E1LTU (103),
mtMl1T1DSUfb (104),
mtMl1T1CSUfb (105),
mtMl1E1DSUfb (106),
mtMl1E1LTUfb (107),
mtMl2T1 (108),
mtMl2E1 (109),
ls2CcittX50 (110),
ls2CcittX58 (111),
ls2ATandTSdm (112),
ls2ACcittX50 (113),
ls2ACcittX58 (114),
ls2AATandTSdm (115),
ls2A2Ts (116),
ls2M (117),
mtMlT1 (118),
mtMlE1 (119),
hs2 (120),
hs3 (121),
hsq (122),
hs703 (123),
hsQM (124),
hsqN (125),
hs6 (126),
hs12 (127),
hsDp (128),
hsp (129),
hs4T1 (130),
hs4E1 (131),
hs4 (132),
hsEth (133),
ml8T1 (134),
ml8E1 (135),
-- Vmux-2100 Voice cards
vc2E1 (136),
vc4E1 (137),
vc2T1 (138),
vc4T1 (139),
vc2EandM (140),
vc2Fxs1Plar (141),
vc2Fxo1 (142),
vc2Fxs2 (143),
vc2Fxo2 (144),
vc2Fxs3 (145),
vc2Fxo3 (146),
vc26EandM (147),
mtvc2 (148),
vc2R2Fxs (149),
hsu (150),
mbeA (151),
mbeB (152),
mbeU (153),
tre (154),
hsuI (155),
hsr (156),
hss (157),
hsu1 (158),
ls12 (159),
ls6 (160),
ls6V1EandM (161),
ls6V1Fxo (162),
ls6V1Fxs (163),
ls6V2EandM (164),
ls6V2Fxo (165),
ls6V2Fxs (166),
ls6VfEandM (167),
ls6VfFxo (168),
ls6VfFxs (169),
vc3EandM (170),
vc3Fxo (171),
vc3Fxs (172),
vcPbx (173),
vcPbxT1 (174),
vcPbxE1 (175),
vc6EandM (176),
vc6Fxo (177),
vc6Fxs (178),
vcq (179),
ls6n (180),
--
-- Packet Cards of MAXcess and Hybrid
--
-- High speed cards
mhs1V36 (181),
mhs1V35 (182),
mhs1G703 (183),
mhs1DDS (184),
mhs3 (185),
mhs1X21 (186),
mhs1V24 (187),
mhs4 (188),
mhsE1Hs (189),
mhsT1Hs (190),
mhsHyE1Hs (191), -- 2 HS ports + 1 Hybrid E1 port
mhsHyT1Hs (192), -- 2 HS ports + 1 Hybrid T1 port
mlfHybE1Hs (193), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid E1 port
mlfHybT1Hs (194), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid T1 port
-- T1/E1 cards
mhs2e1 (195),
mhs2t1 (196),
mhsHy2e1 (197), -- 2 Hybrid E1 ports
mhsHy2t1 (198), -- 2 Hybrid T1 ports
mlfHybE12 (199), -- Fiber Optic Hybrid: 2 E1 ports
-- Low speed cards
mls6 (200),
mls3 (201),
-- More T1/E1 cards
mlHybAtmE1 (202), -- Hybrid ATM E1
mlHybAtmT1 (203), -- Hybrid ATM T1
mlfHybT12 (204), -- Fiber Optic Hybrid: 2 T1 ports
-- Voice cards
mvc8 (205), -- MVC-8 name in marketing: MVC-4N
mvc8PbxE1 (206),
mvc8PbxT1Dsu (207),
mvc8PbxT1Csu (208),
mvc8PbxE1Slave (209),
mvc4 (210),
mvc4PbxE1 (211),
mvc4PbxT1Dsu (212),
mvc4PbxT1Csu (213),
mvc4PbxE1Slave (214),
mvc4PbxT1Slave (215),
mvc8PbxT1Slave (216), -- MVC-8 T1 Slave is here
mvc8ExtAnalog (217), -- MVC-8 with 8 External ports
mvcE1 (218), -- 8 External ports & 30 Internals
mvcT1 (219), -- 8 External ports & 24 Internals
-- ISDN for Maxcess
mhsS (220),
mhsU (221),
mhsPriE1 (222),
mhsPriT1 (223),
--Card of MP-2100/4
hsEthSwitch (224),
-- CCS for Maxcess & MPH
mPriE1FramerCcs (225),
mPriT1FramerCcs (226),
mPriE1SlaveCcs (227),
mPriT1SlaveCcs (228),
mDualBri (229),
--Voice cards for MP
vc12EandM (230),
vc12Fxo (231),
vc12Fxs (232),
vc6aEandM (233),
vc6aFxo (234),
vc6aFxs (235),
vc6AgFxo (236),
vc6AgFxs (237),
vc6a4LB (238),
--Video card for MP
vid (239),
--ISDN cards for MP
hsu12 (240),
hsu6 (241),
hss12 (242),
hss6 (243),
-- MPH and MP-2100/4 cards
hsDp3 (244),
hsDp6 (245),
-- MP-2100/4 card
hsf1 (246),
-- More Hybrid cards + IP cards for MPH
mhsHyE1 (247), -- 1 Hybrid E1 port
mhsHyT1 (248), -- 1 Hybrid T1 port
mhsIp (249), -- 1 Eth port + 1 HS port
mlIpHs (250), -- 1 Eth port + 3 HS ports
mlHybIpE1 (251), -- 1 Eth port + 1 HS port + 1 E1
mlHybIpT1 (252), -- 1 Eth port + 1 HS port + 1 T1
-- VOIP cards for MPH & MX
mvg1Lan (253),
mvg2Lan (254),
-- MP-2100/4 card
vc4Fxs (255),
vc4EandM (256),
vc4Fxo (257),
hsf2 (258),
-- More VOIP cards for MPH
mvgSwitch4Lan (260),
--SHDSL cards of Megaplex
msl4E1W2 (261),
msl4E1W4 (262),
msl8E1W2 (263),
msl4E1W2Eth (264),
msl8E1W2Eth (265),
asmi54cE1AndEth (266), -- & LRS-102 (E1 & ETH)
asmi54cT1AndEth (267), -- & LRS-102 (T1 & ETH)
asmi54c (268), -- & LRS-102 (ETH only)
--HS cards of Megaplex
hs6N (271),
hs12N (272),
hsNRZ (273),
-- Vmux 2100 Enhanced Voice Cards
evc2E1 (281),
evc4E1 (282),
evc2T1 (283),
evc4T1 (284),
-- Vmux-2200 Voice cards
vc2E1Pri (285),
vc4E1Pri (286),
-- MP Voice cards
vc4OmniEandM (291),
vc4OmniWestern (292),
-- MP-4100 and/or LRS-102 cards
clx1 (301),
clx1GbE (302),
clx1S155 (303),
clx1S155GbE (304),
ml8T1Eth (305),
ml8E1Eth (306),
op106cEth (307), --no external T1
op108cEth (308), --no external E1
op106cEthT1 (309), --with external T1 (used also by LRS-102)
op108cEthE1 (310), --with external E1 (used also by LRS-102)
op108cEthE1Unbal (311), --used only by LRS-102
mpw1 (312),
-- VFS cards of Megaplex
vfs24T1 (321),
vfs30E1 (322),
vfs48T1 (323), --2T1
vfs60E1 (324), --2E1
-- MiniCVS cards
mm4E1 (325),
mm4T1 (326),
mm8E1 (327),
mm8T1 (328),
mm12E1 (329),
mm12T1 (330),
mm16E1 (331),
mm16T1 (332)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the type of card installed
in the specific slot position.
Only PS cards are possible in the PS slots.
Only CL cards are possible in the CL slots.
Only IO cards are possible in the IO slots."
::= { mdlSInstEntry 2}
mdlSHwVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Hardware version of the
installed card in the specific slot position."
::= { mdlSInstEntry 3 }
mdlSSwVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Software version of the
installed card in the specific slot position."
::= {mdlSInstEntry 4}
mdlSAlrStatus OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state at module level, i.e. lower level
(port alarms) status is not included.
This attribute will be set to:
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= { mdlSInstEntry 5 }
mdlSAlrStatusAll OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state in the module-all level, i.e. lower level
(port alarms) included.
This attribute will be set to:
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= { mdlSInstEntry 6 }
mdlSMaskedAlrStat OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state at module level, [i.e. lower level
(port alarms) status is not included],including Masked alarms.
This attribute will be set to:
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= { mdlSInstEntry 7 }
mdlSMaskedAlrStatAll OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state in the module-all level, i.e. lower level
(port alarms) included, including Masked alarms.
This attribute will be set to:
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= { mdlSInstEntry 8 }
mdlSTstStatusAll OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute will be set to on(3) when there is at least
one test in progress on a channel of the card, otherwise
the value will be off(2)."
::= { mdlSInstEntry 9 }
mdlSClearAlrCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this command to ON, enforces a clear of all the
alarms in the given slot, excluding alarms of port level.
The clear operation will not be applied for masked/inverted
alarms."
::= { mdlSInstEntry 10 }
mdlSClearAllAlrCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this command to ON, enforces a clear of all the
alarms in the given slot, including all its ports alarms.
The clear operation will not be applied for masked/inverted
alarms."
::= { mdlSInstEntry 11 }
mdlSTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature of the card, in Celsius degrees."
::= { mdlSInstEntry 12 }
mdlSAlrTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlSAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The list of card agent alarms ; includes also an alarm
indicating existence of alarms on its ports if there are any."
::= { statMdlGen 2 }
mdlSAlrEntry OBJECT-TYPE
SYNTAX MdlSAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {mdlSAlrSltIdx , mdlSAlrIdx}
::= { mdlSAlrTable 1}
MdlSAlrEntry ::=
SEQUENCE {
mdlSAlrSltIdx INTEGER,
mdlSAlrIdx Integer32,
mdlSAlrCodeDescription DisplayString,
mdlSAlrCode Integer32,
mdlSAlrSeverity INTEGER,
mdlSAlrState INTEGER,
mdlSAlrCounter Integer32,
mdlSAlrMask INTEGER,
mdlSAlrInvert INTEGER
}
mdlSAlrIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify an entry in the alarm status table.
Users should use the get next function to read this table because
the indexes are not consecutive."
::= { mdlSAlrEntry 1}
mdlSAlrSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the desired slot position.
In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16)
are not valid.
For the Vmux2100 Main Board clA (3) is used."
::= { mdlSAlrEntry 2}
mdlSAlrCodeDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is a full text description of the alarm .
The alarm description includes the following information:
alarm code, alarm text, alarm severity, Masked or Inverted
flag and counter."
::= { mdlSAlrEntry 3}
mdlSAlrCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A code identifying the alarm of an entry in the alarm status
table at card level."
::= { mdlSAlrEntry 4 }
mdlSAlrSeverity OBJECT-TYPE
SYNTAX INTEGER
{
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity of the alarm."
::= { mdlSAlrEntry 5 }
mdlSAlrState OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the alarm."
::= { mdlSAlrEntry 6 }
mdlSAlrCounter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A counter - how many times the alarm occured since last
clear operation.
ON and OFF Alarm will be counted separately."
::= { mdlSAlrEntry 7 }
mdlSAlrMask OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm mask : on/off."
::= { mdlSAlrEntry 8 }
mdlSAlrInvert OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm invert : on/off."
::= { mdlSAlrEntry 9 }
--
-- Wan module configuration information
--
mdlCPrgTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlCPrgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { cnfgMdlGen 1 }
mdlCPrgEntry OBJECT-TYPE
SYNTAX MdlCPrgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mdlCCnfgIdx, mdlCSltIdx }
::= { mdlCPrgTable 1}
MdlCPrgEntry ::=
SEQUENCE {
mdlCCnfgIdx Integer32,
mdlCSltIdx INTEGER,
mdlCPrgCardType INTEGER,
mdlCNoOfExternPrt Integer32, -- RO
mdlCNoOfInternPrt Integer32, -- RO
mdlCWorkMode INTEGER,
mdlCDhcpClientEnable INTEGER,
mdlCRdnExists INTEGER, -- RO
mdlCInterfaces OCTET STRING
}
mdlCCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg(1..100) being
referred.
Value 255 specifies the TmpCnfg "
::= { mdlCPrgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
mdlCSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number of the slot
position where the card is inserted.
In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16)
are not valid."
::= { mdlCPrgEntry 2}
mdlCPrgCardType OBJECT-TYPE
SYNTAX INTEGER
{
--
-- General types
--
unknown (1),
empty (2),
-- (3)..(7) are reserved ; they appear in the compress structure
acm (9), --alarm module
--
-- Power Supply Modules
--
ps48x60W (10),
ps48x100W (11),
ps110x60W (12),
ps110x100W (13),
ps220x60W (14),
ps220x100W (15),
ps180W (16),
ps (17),
--
-- Cl Modules
--
cl1 (20),
clEth (21),
cl2 (22),
cl2Eth (23),
cl3 (24),
cl3Eth (25),
cl1Clk (26), --CL1 with Station Clock (for LRS102)
--
-- Packet Cards of Megaplex
--
mPh1 (31),
mPh3 (32),
mPh1T1DSU (33),
mPh1T1CSU (34),
mPh1E1DSU (35),
mPh1E1LTU (36),
-- TDM Cards
mtmlFT1 (37),
mtmlFE1 (38),
mtmlH4E1 (39),
mtmlH4E12W (40),
mtmlH4T1 (41),
mtmlH4T12W (42),
mtHsh4E1 (43),
mtHsh4E12W (44),
mtHsh4T1 (45),
mtHsh4T12W (46),
mtmlH2E1 (47),
mtmlH2E12W (48),
mtmlH2T1 (49),
mtmlH2T12W (50),
hsh2E1 (51),
hsh2E12W (52),
hsh2T1 (53),
hsh2T12W (54),
mlIp (55),
mtml4Ip (56),
ml20N1 (57),
ml20N2 (58),
-- Packet Cards of Megaplex
mPl6 (60),
-- mPl3 (61),
-- VF cards of Megaplex
vf24T1 (62),
vf30E1 (63),
vf48T1 (64),
vf60E1 (65),
-- Vmux-2100 Main Link cards
ml2E1 (68),
ml4E1 (69),
ml2T1 (70),
ml4T1 (71),
-- mPv4 (72),
--
-- TDM Cards
--
vc16A (73),
vc8EandM (74),
vc8Fxo (75),
vc8Fxs (76),
vc16EandM (77),
vc16Fxo (78),
vc16Fxs (79),
vf3EandM (80),
vf3Fxs (81),
vf3Fxo (82),
vfPbx (83),
vfPbxT1 (84),
vfPbxE1 (85),
mtMlE2S (86), --Single Link
mtMlE2D (87), --Dual Link
mtMlF2T1 (88),
mtMlF2E1 (89),
mtMlT1Fiber (90),
mtMlE1Fiber (91),
mtMlT1FiberFb (92),
mtMlE1FiberFb (93),
mtmlHE1 (94),
mtmlH1E1 (95),
mtmlHSE1 (96),
ml20 (97),
mtMl4T1 (98),
mtMl4E1 (99),
mtMl1T1DSU (100),
mtMl1T1CSU (101),
mtMl1E1DSU (102),
mtMl1E1LTU (103),
mtMl1T1DSUfb (104),
mtMl1T1CSUfb (105),
mtMl1E1DSUfb (106),
mtMl1E1LTUfb (107),
mtMl2T1 (108),
mtMl2E1 (109),
ls2CcittX50 (110),
ls2CcittX58 (111),
ls2ATandTSdm (112),
ls2ACcittX50 (113),
ls2ACcittX58 (114),
ls2AATandTSdm (115),
ls2A2Ts (116),
ls2M (117),
mtMlT1 (118),
mtMlE1 (119),
hs2 (120),
hs3 (121),
hsq (122),
hs703 (123),
hsQM (124),
hsqN (125),
hs6 (126),
hs12 (127),
hsDp (128),
hsp (129),
hs4T1 (130),
hs4E1 (131),
-- hs4 (132),
hsEth (133),
ml8T1 (134),
ml8E1 (135),
-- Vmux-2100 Voice cards
vc2E1 (136),
vc4E1 (137),
vc2T1 (138),
vc4T1 (139),
vc2EandM (140),
vc2Fxs1Plar (141),
vc2Fxo1 (142),
vc2Fxs2 (143),
vc2Fxo2 (144),
vc2Fxs3 (145),
vc2Fxo3 (146),
vc26EandM (147),
mtvc2 (148),
vc2R2Fxs (149),
hsu (150),
mbeA (151),
mbeB (152),
mbeU (153),
tre (154),
hsuI (155),
hsr (156),
hss (157),
hsu1 (158),
ls12 (159),
ls6 (160),
ls6V1EandM (161),
ls6V1Fxo (162),
ls6V1Fxs (163),
ls6V2EandM (164),
ls6V2Fxo (165),
ls6V2Fxs (166),
ls6VfEandM (167),
ls6VfFxo (168),
ls6VfFxs (169),
vc3EandM (170),
vc3Fxo (171),
vc3Fxs (172),
vcPbx (173),
vcPbxT1 (174),
vcPbxE1 (175),
vc6EandM (176),
vc6Fxo (177),
vc6Fxs (178),
vcq (179),
ls6n (180),
--
-- Packet Cards of Maxcess and Hybrid
--
-- High speed cards
mhs1V36 (181),
mhs1V35 (182),
mhs1G703 (183),
mhs1DDS (184),
mhs3 (185),
mhs1X21 (186),
mhs1V24 (187),
mhs4 (188),
mhsE1Hs (189),
mhsT1Hs (190),
mhsHyE1Hs (191), -- 2 HS ports + 1 Hybrid E1 port
mhsHyT1Hs (192), -- 2 HS ports + 1 Hybrid T1 port
mlfHybE1Hs (193), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid E1 port
mlfHybT1Hs (194), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid T1 port
-- T1/E1 cards
mhs2e1 (195),
mhs2t1 (196),
mhsHy2e1 (197), -- 2 Hybrid E1 ports
mhsHy2t1 (198), -- 2 Hybrid T1 ports
mlfHybE12 (199), -- Fiber Optic Hybrid: 2 E1 ports
-- Low speed cards
mls6 (200),
mls3 (201),
-- More T1/E1 cards
mlHybAtmE1 (202), -- Hybrid ATM E1
mlHybAtmT1 (203), -- Hybrid ATM T1
mlfHybT12 (204), -- Fiber Optic Hybrid: 2 T1 ports
-- Voice cards
mvc8 (205), -- MVC-8 name in marketing: MVC-4N
mvc8PbxE1 (206),
mvc8PbxT1Dsu (207),
mvc8PbxT1Csu (208),
mvc8PbxE1Slave (209),
mvc4 (210),
mvc4PbxE1 (211),
mvc4PbxT1Dsu (212),
mvc4PbxT1Csu (213),
mvc4PbxE1Slave (214),
mvc4PbxT1Slave (215),
mvc8PbxT1Slave (216), -- MVC-8 T1 Slave is here
mvc8ExtAnalog (217), -- MVC-8 with 8 External ports
mvcE1 (218), -- 8 External ports & 30 Internals
mvcT1 (219), -- 8 External ports & 24 Internals
-- ISDN for Maxcess
mhsS (220),
mhsU (221),
mhsPriE1 (222),
mhsPriT1 (223),
--Card of MP-2100/4
hsEthSwitch (224),
-- CCS for Maxcess & MPH
mPriE1FramerCcs (225),
mPriT1FramerCcs (226),
mpriE1SlaveCcs (227),
mpriT1SlaveCcs (228),
mDualBri (229),
--Voice cards for MP
vc12EandM (230),
vc12Fxo (231),
vc12Fxs (232),
vc6aEandM (233),
vc6aFxo (234),
vc6aFxs (235),
vc6AgFxo (236),
vc6AgFxs (237),
vc6a4LB (238),
--Video card for MP
vid (239),
--ISDN cards for MP
hsu12 (240),
hsu6 (241),
hss12 (242),
hss6 (243),
-- MPH and MP-2100/4 cards
hsDp3 (244),
hsDp6 (245),
-- MP-2100/4 card
hsf1 (246),
-- More Hybrid cards + IP cards for MPH
mhsHyE1 (247), -- 1 Hybrid E1 port
mhsHyT1 (248), -- 1 Hybrid T1 port
mhsIp (249), -- 1 Eth port + 1 HS port
mlIpHs (250), -- 1 Eth port + 3 HS ports
mlHybIpE1 (251), -- 1 Eth port + 1 HS port + 1 E1
mlHybIpT1 (252), -- 1 Eth port + 1 HS port + 1 T1
-- VOIP cards for MPH & MX
mvg1Lan (253),
mvg2Lan (254),
-- MP-2100/4 card
vc4Fxs (255),
vc4EandM (256),
vc4Fxo (257),
hsf2 (258),
-- More VOIP cards for MPH
mvgSwitch4Lan (260),
--SHDSL cards of Megaplex
msl4E1W2 (261),
msl4E1W4 (262),
msl8E1W2 (263),
msl4E1W2Eth (264),
msl8E1W2Eth (265),
asmi54cE1AndEth (266), -- & LRS-102 (E1 & ETH)
asmi54cT1AndEth (267), -- & LRS-102 (T1 & ETH)
asmi54c (268), -- & LRS-102 (ETH only)
--HS cards of Megaplex
hs6N (271),
hs12N (272),
hsNRZ (273),
-- Vmux 2100 Enhanced Voice Cards
evc2E1 (281),
evc4E1 (282),
evc2T1 (283),
evc4T1 (284),
-- Vmux-2200 Voice cards
vc2E1Pri (285),
vc4E1Pri (286),
-- MP Voice cards
vc4OmniEandM (291),
vc4OmniWestern (292),
-- MP-4100 and/or LRS-102 cards
clx1 (301),
clx1GbE (302),
clx1S155 (303),
clx1S155GbE (304),
ml8T1Eth (305),
ml8E1Eth (306),
op106cEth (307), --no external T1
op108cEth (308), --no external E1
op106cEthT1 (309), --with external T1 (used also by LRS-102)
op108cEthE1 (310), --with external E1 (used also by LRS-102)
op108cEthE1Unbal (311), --used only by LRS-102
mpw1 (312),
-- VFS cards of Megaplex
vfs24T1 (321),
vfs30E1 (322),
vfs48T1 (323), --2T1
vfs60E1 (324) --2E1
-- MiniCVS cards: This is a placeholder. The following cards exist only in the mdlSInstCardType.
-- mm4E1 (325),
-- mm4T1 (326),
-- mm8E1 (327),
-- mm8T1 (328),
-- mm12E1 (329),
-- mm12T1 (330),
-- mm16E1 (331),
-- mm16T1 (332)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the type of card assigned to the
specific slot in the common configuration.
This object is identical in all the configurations (1..100).
Only the TmpCnf(255) may have different value.
The write operation is valid only to the TmpCnfg entry."
::= { mdlCPrgEntry 3}
mdlCNoOfExternPrt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of external ports in the programmed card of the
specific slot position"
::= { mdlCPrgEntry 4}
mdlCNoOfInternPrt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of internal ports in the programmed card of the
specific slot position."
::= { mdlCPrgEntry 5}
mdlCWorkMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
standAlone (2),
integrated (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Working mode of the card.
The user may configure the card to work in a stand alone mode or integrated
with the device.
Example for use in MHS-IP cards:
- standAlone - in this mode, the router works so that data is received
via the LAN (Eth) port and is transmitted via the WAN (HS) external port
without going through the MPH device.
- integrated - in this mode, the router works so that it is integrated in the MPH
and routes DLCIs into the device."
::= { mdlCPrgEntry 6}
mdlCDhcpClientEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable the feature of DHCP Client for the selected card."
::= { mdlCPrgEntry 7}
mdlCRdnExists OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates whether any port of the programmed card is
configured to be part of a Redundancy/APS pair.
If at least one port of the programmed card is configured to be
part of a Redundancy/APS pair, the value will be 'yes'.
Otherwise, it will be 'no'."
::= { mdlCPrgEntry 8}
mdlCInterfaces OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Octet string which indicates 'present' interfaces in card.
Each '0' bit stands for non-present interface.
Each '1' bit stands for present interface.
For ASMi54C card of LRS-102 and MP-4100 notPresent interfaces may be:
- SHDSL Line ID with no wire pairs assigned to it (does not exist in ifTable)
- PCS without SHDSL Line binded to it, (exist in ifTable, with
ifOperStatus= notPresent)
- External DS1 when its LIU is used by an Internal DS1 of the same card
- Internal DS1 when single bearer is not TDM.
In each octet, MS bit represents port 1
and LS bit represents port 8
MSB LSB
1 0 0 0 1 0 0 0 -- Example: Port # 1 and 5 are present.
Port 1 2 3 4 5 6 7 8
1st Octet (MSB octet) represents SDHSL Lines
2nd Octet represents PCS
3rd Octet represents External DS1
4th Octet represents Internal DS1
5th and 6th Octets are reserved for future Internal DS1.
For OP-108/106 cards of LRS-102 and MP-4100 notPresent interfaces may be:
- External DS1 when its 'associated' Int-DS1 port is connected to another card
- Internal DS1 when its 'associated' Ext-DS1 port is connected to another card
(Both may be 'present' when inter-connected).
1st Octet represents External DS1
2nd Octet represents Internal DS1
Bit representation, same as for ASMi-54C card.
"
::= { mdlCPrgEntry 9 }
--
-- Compressed information.
--
-- Specially for RadView management station
--
mdlCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { cmprMdlGen 1 }
mdlCmprEntry OBJECT-TYPE
SYNTAX MdlCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mdlCmprTypIdx, mdlCmprCnfgIdx ,mdlCmprVersion,mdlCmprSltIdx }
::= {mdlCmprTable 1}
MdlCmprEntry ::=
SEQUENCE {
mdlCmprTypIdx Integer32,
mdlCmprCnfgIdx Integer32,
mdlCmprVersion Integer32,
mdlCmprSltIdx INTEGER,
mdlCmprObj OCTET STRING
}
mdlCmprTypIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Type of the Compressed being
referred."
::= { mdlCmprEntry 1}
mdlCmprCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the configuration to which the
Compressed information is related."
::= { mdlCmprEntry 2}
mdlCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal format
of the Compressed data"
::= { mdlCmprEntry 3}
mdlCmprSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number of the slot
position where the card is inserted.
In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16)
are not valid."
::= { mdlCmprEntry 4}
mdlCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { mdlCmprEntry 5}
-- Compressed Alarm table at Card level
-- The only way of reading this table is by the command 'GET NEXT'
mdlAlarmsCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlAlarmsCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= {cmprMdlGen 2}
mdlAlarmsCmprEntry OBJECT-TYPE
SYNTAX MdlAlarmsCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {mdlAlarmsCmprVersion,
mdlAlarmsCmprAlarmSlot,mdlAlarmsCmprAlarmIdx}
::= {mdlAlarmsCmprTable 1}
MdlAlarmsCmprEntry ::=
SEQUENCE {
mdlAlarmsCmprVersion Integer32,
mdlAlarmsCmprAlarmSlot Integer32,
mdlAlarmsCmprAlarmIdx Integer32,
mdlAlarmsCmprObj OCTET STRING
}
mdlAlarmsCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal format
of the Compressed data"
::= { mdlAlarmsCmprEntry 1}
mdlAlarmsCmprAlarmSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the desired slot position.
In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16)
are not valid."
::= { mdlAlarmsCmprEntry 2}
mdlAlarmsCmprAlarmIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify an entry in the alarm status table
of the agent."
::= { mdlAlarmsCmprEntry 3}
mdlAlarmsCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { mdlAlarmsCmprEntry 4}
--
-- Wan port status general information
--
prtSInstTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSInstEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { statPrtGen 1 }
prtSInstEntry OBJECT-TYPE
SYNTAX PrtSInstEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtSInstSltIdx, prtSInstPrtIdx }
::= { prtSInstTable 1}
PrtSInstEntry ::=
SEQUENCE {
prtSInstSltIdx INTEGER,
prtSInstPrtIdx Integer32,
prtSInstPrtType INTEGER,
prtSInstIfIndex Integer32,
prtSActiveStatus INTEGER,
prtSAlrStatus INTEGER,
prtSMaskedAlrStat INTEGER,
prtSClearAlrCmd INTEGER,
prtSTestMask Integer32,
-- prtSTstStatus INTEGER,
prtSTstCmd INTEGER,
prtSTstDuration Integer32,
prtSBertClrCmd INTEGER,
prtSBertTstRslt Integer32,
prtSInterfaceType DisplayString,
prtSParamStatus OCTET STRING,
prtSTestMaskXp OCTET STRING,
prtSRdnStatus INTEGER
}
prtSInstSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify the
slot where the card is inserted.
In the ?004 Unit the entries io6(10)..io(16) are not valid.
For the Vmux2100 Main Board clA (3) is used."
::= { prtSInstEntry 1}
prtSInstPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify a port
in a specific card.
The valid ports depend on the installed card:
the valid external ports (interfaces) are (1..mdlCNoOfExternPrt) if any,
and the valid internal ports are (101..100+mdlCNoOfInternPrt) if any.
Generally, for MP-2100/2200: exPrt1 (1) .. exPrt16 (16),inPrt1(101)
.. inPrt48 (148)
For the Vmux-2100 device:
This index will have values of 1...4 for the physical ports & values
of ifIndex for the bundles.
For other products, see product's spec."
::= { prtSInstEntry 2}
prtSInstPrtType OBJECT-TYPE
SYNTAX INTEGER
{
external (2),
internal (3),
highSpeedV35 (4),
highSpeedV24 (5),
highSpeedV36 (6),
highSpeedX21 (7),
highSpeedG703 (8),
highSpeedDDS (9),
lowSpeed (10),
voice (11),
cl (12),
isdns (13),
isdnu (14),
ethernet (15),
voiceS0 (16),
voiceU (17),
voiceQsigS (18),
voiceQsigU (19)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the type of the designated port.
In MX 3000 only external & internal options are used.
All the other options are only for MX 30/300 which need special handling.
In order to support interface types in MX 3000, return an ascii string for
prtSInterfaceType in this table or support the general RAD value of
physicalConnector.
External port - is a port with a physical connector.
Internal port - might be of two types:
a) A composite port which collects a few external ports
data into a common bandwidth (usually routed through
DS1 link)
b) A port which gets only part of the external ports
(usually a few DS0's)
The following types are used when all ports are external/
internal and the connector/interface type is necessary
(for example, stand-alone units):
High Speed port types
Low Speed port types
Voice port types, CL port types.
ISDN Voice in MX 30/300 Phase 4: voiceS0 (16), voiceU (17) should be used.
ISDN Voice in MX 30/300 Phase 5: voiceQsigS(18), voiceQsigU (19) should be used."
::= { prtSInstEntry 3}
prtSInstIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the unique interface number
assigned to the port. The specific interface of this
attribute is the same as the interface identified by the
value of ifindex in MIB-II.If there is no interface for
the specific prtIdx the value will be '7fffffff'h."
::= { prtSInstEntry 4}
prtSActiveStatus OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
notUsed (2),
offLine (3),
onLine (4),
offLineRedundancy (5),
onLineRedundancy (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the activity status of the port.
unknown(1) indicates that the information is not supported.
notUsed(2) indicates that the ch is not connected according
to the active config.
offLine(3) indicates that the ch is down (not working)
because of any problem.
onLine(4) indicates that the ch is up (working)
offLineRedundancy(5) indicates that the ch is down, because
it is redundant port.
onLineRedundancy(6) indicates that the ch is up, and it is
the active link"
::= { prtSInstEntry 5}
prtSAlrStatus OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state in the port(ch) agent level.
This attribute will be set to:
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= { prtSInstEntry 6}
prtSMaskedAlrStat OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state in the port(ch) agent level,
including Masked alarms.
This attribute will be set to:
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= {prtSInstEntry 7}
prtSClearAlrCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on(3) enforces a clear operation
of the alarm status events in the given port. The clear
operation will not be applied for masked/inverted alarms."
::= { prtSInstEntry 8}
prtSTestMask OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a mask which indicates which tests from the
'prtSTstCmd' list are allowed for the requested port.
If a specific test is allowed, its respective bit
will be SET in the mask :
TEST BIT
----------- ---
local-loop 1
remote-loop 2
loc-and-rem-main-loops 3
remote-analog-loop 4
remote-digital-loop 5
rem-loop-on-ext-unit 6
bert 7
tone-injection 8
dlci local-loop 9
all dlci local-loop 10
dlci remote-loop 11
all dlci remote-loop 12
bert-and-rem-loop-on-rem-unit 13
rem-loop-on-rem-unit 14
block 15
backward-tone-inject 16
llb 17
rlb 18
ft1Enable 21
lbbd 22 --for 2B+D
lb1 23 --for B1
lb2 24 --for B2
llb-on-rem-unit 25
bert-on-rem-unit 26
bert-on-rem-and-llb-on-rem-unit 27
local-and-bert-on-rem-unit 28
local-loop-on-rem-unit 29
localBert 30 --towards IO ports
test-per-TS 31
e.g : If the return value is 3 -> 0000000000000011 ->
Bits 1 & 2 are set -> the allowed tests are :
local-loop
remote-loop
"
::= { prtSInstEntry 9}
-- prtSTstStatus OBJECT-TYPE
-- SYNTAX INTEGER
-- {
-- off(2),
-- on (3)
-- }
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This attribute will be set to on(3) when there is at least
-- one test in progress in the port, otherwise the value
-- will be off(2)."
-- ::= { prtSInstEntry 10}
--
prtSTstCmd OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
localLoop (2),
remoteLoop (3),
locAndRemMainLoops (4),
remoteAnalogLoop (5),
remoteDigitalLoop (6),
remLoopOnExtUnit (7),
bert (8),
toneInjection (9),
dlciLocalLoop (10),
allDlciLocalLoop (11),
dlciRemoteLoop (12),
allDlciRemoteLoop (13),
extInitLocalLoop (14),
bertAndRemLoopOnRemUnit (15),
remLoopOnRemUnit (16),
block (17),
backwardToneInject (18),
llb (19),
rlb (20),
ft1Enable (21),
lbbd (22), --for 2B+D
lb1 (23), --for B1
lb2 (24), --for B2
llbOnRemUnit (25),
bertOnRemUnit (26),
bertOnRemAndLlbOnRemUnit (27),
localAndBertOnRemUnit(28),
localLoopOnRemUnit (29),
localBert (30),
testPerTS (31),
csuLoopAndBert (32),
dsuLoopAndBert (33),
remoteOcuLoopAndBert (34),
remoteCsuLoopAndBert (35),
remoteDsuLoopAndBert (36)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to any of the above values will
initiate a test on the specific port if the operation is
legal. If the operation is not legal, the mux will ignore
the operation.
testPerTS(31) - when this test is selected, the selection of tests
for each TS is done via the prtExPh1MlTsTest object.
If a test time out is needed, the test will be set with a
default timeout of 2 minutes until the user will set the
parameter 'prtSTstDuration' to the required time out.
If no time out is needed , the test will be set with infinite
timeout until the user will set the parameter
'prtSTstDuration' to the required time out."
::= { prtSInstEntry 10}
prtSTstDuration OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the maximum duration of executing
a test on the specific port. This entry applies to all the
test operations. The resolution will be a minute, and the
maximum duration is limited to 30 minutes.
For Vmux devices, the values are in seconds.
A zero value specifies no time limitation.
When the test isn't active, the agent initiates this object to
2 when the duration is needed and to 0 if its not required.
The user should set this parameter after setting the
'prtSTstCmd' parameter."
::= { prtSInstEntry 11}
prtSBertClrCmd OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute initiates bert count clear operation.
It is valid only when bert test is active on the specific
port."
::= { prtSInstEntry 12}
prtSBertTstRslt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the number of Bit Error Rate
indicated during the BERT operation.
It is valid only when bert test is active on the specific
port."
::= { prtSInstEntry 13}
prtSInterfaceType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique HW interface type of the
selected port."
::= { prtSInstEntry 14}
prtSParamStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates Status of parameters specific to the
selected port.
- For a port that has no special status or is supported
by prtSExHsfStatTable - 1 Octet: 00hex
- For VC-6, VC-6A, VC-6AG, VC-6A/4LB, VC-12, VC-12/6, external ports - 1 Octet :
Bit 7 (MSB)..Bit 2 = 0 (NA)
Bit 1: Tx Signaling '1'=On ; '0'=Off
Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off
- For VC-2/R2(FXS) external ports - 1 Octet :
Bit - 7 6 5 4 3 2 1 0
|_| |_________|
Call Call State
Direction
Bit 7 (MSB) and Bit 6 : Call Direction
00 - Incoming
01 - Outgoing
Bit 5..Bit 0: Call State
000000 - Idle
000001 - Seized
000010 - Both-Way Conflict
000011 - Seizure Ack
000100 - Answered
000101 - Clear Backward
000110 - Clear Forward
000111 - Blocked
001000 - Fault
001001 - Fault 3
001010 - Fault 4
001011 - Fault 5
001100 - Fault 6
001101 - Fault 7
- For ML-20 external port - 3 Octets :
- 1 MS Octet will represent the Real Rate used:
Bit - 7 6 5 4 3 2 1 0
|___| |_______|
spare Rate
Valid values: 0..31, meaning 0..31x64Kbps
Invalid values: 32..255.
- 2 LS Octets will represent the Status of 7 Control
Signals:
Signal - --- CTS DSR DCD RJ TM DTR RTS
Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Octet - 2 3 (LS)
'---' will always have the value 00
Rest of the Signals (2 bits each) can have the following
values:
00=NA ; 01=unused ; 10=Off ; 11=On
- For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet
Bit - 7 6 5 4 3 2 1 0
|___________|
spare Mode of Operation
Mode of Operation: '1'=Central ; '0'=Remote
- For ACM external port - 1 Octet
Bit - 7 6 5 4 3 2 1 0
|_________|
spare Alarm State
Alarm State: according to bits 1,0:
00=NA ; 01=unused ; 10=Off ; 11=On
- For HS-U/1 external port - 1 Octet
Bit 7 6 5 4 3 2 1 0 LSB
|________| |__| |__|
spare modem sync
modem: 00 = other sync: 00 = not sync
01 = unknown 01 = sync
10 = ASMi-31/2 10 = reserved
11 = reserved 11 = reserved
- For MTML-2/4 external ports, ML-8 externalports, ML-IP (MTML-IP)
internal ports and MTML-E2 internal ports - 1 Octet :
Bit 7 6 5 4 3 2 1 0 LSB
|
BERT State
BERT State (Bit 0):
0 = OFF (BERT is not running on this port or any of its TSs/Bits)
1 = ON (BERT is running on this port OR on one of its TSs/Bits)
- For ML-20N external ports - 4 Octets
- 1 MS Octet will represent the Actual Link Rate:
Bit - 7 6 5 4 3 2 1 0
|_| |_________|
spare Rate
Valid values: 0..34, meaning:
0..32 = (0..32)x64Kbps
33 = Invalid Rate
34 = not applicable (when Rate is not Auto)
35 = 0 Kbps
Invalid values: 36..255.
- 2 middle Octets will represent the Status of 4 Control
Signals:
- LS Octet - Bits 3-0: RTS/C (Command, for X.21 interface)
Bits 7-4: DCD/I (Indication for X.21 interface)
- MS Octet - Bits 3-0: DTR
Bits 7-4: DSR
Each 4 Bits are divided as follows:
- 2 MS bits: DCE
- 2 LS bits: DTE
For each 2 bits (DCE/DTE):
00=NA ; 01=unused ; 10=Off ; 11=On.
- LS Octet: (as for MTML-2):
Bit 7 6 5 4 3 2 1 0 LSB
|
BERT State
BERT State (Bit 0):
0 = OFF (BERT is not running on this port or any of its TSs/Bits)
1 = ON (BERT is running on this port OR on one of its TSs/Bits)
- For MP-2100/2200 MSL-4/E1, MSL-8/E1 External ports - 3 Octets
- MS octet: far-end modem channel interface
- Middle octet: Material (plastic/metal), far-end modem type,
synchronization with far-end modem
- LS octet: BERT state (at port/TS/Bit level)
- MS octet: 0000 0000 = no interface
0000 0001 = db15 (X21)
0000 0010 = IR-IP
0000 0011 = IR-ETH-Q
0000 0100 = V35
0000 0101 = ETH-RJ45
0000 0110 = G703
0000 0111 = db25 (RS530)
0000 1000 = ETH-BNC
0000 1001 = E1(Balanced)
0000 1010 = E1(Unbalanced)
0000 1011 = IR-ETH-QN
Rest of the combinations: reserved
- Middle octet:
Bit 7 6 5 4 3 2 1 0 LSB
| |___________| |__|
Box material modem sync
Box material modem: 00000 = other sync: 00 = not sync
(for ASMi-52 SA) 00001 = unknown 01 = sync
0=metal 00010 = reserved 10 = reserved
1=plastic 00011 = reserved 11 = reserved
00100 = reserved
00101 = reserved
00110 = ASMi-52 SA/2W/Slave
00111 = ASMi-52 SA/2W/Master
01000 = ASMi-52/CQ card of LRS-24
01001 = ASMi-52/CD card of LRS-24
01010 = D16GSDSL card of DXC-3000
01011 = LRS-52
01100 = FCD-IP
01101 = FCD-IPM
01110 = D8SL card of DXC-30
01111 = ASMi-52A
10000 = MP card (SHDSL)
10001 = ASMi-52L
Rest = reserved
- LS Octet: (as for MTML-2):
Bit 7 6 5 4 3 2 1 0 LSB
|
BERT State
BERT State (Bit 0):
0 = OFF (BERT is not running on this port or any of its TSs)
1 = ON (BERT is running on this port OR on one of its TSs)
- For MP-4100 MSL card Links - 4 Octets
- MS octet: far-end modem DTE2 interface (same as for MP-2100 MSL cards)
- after MS octet: far-end modem DTE1 interface (same as for MP-2100 MSL cards)
- before LS octet: Material (plastic/metal), far-end modem type,
synchronization with far-end modem (same as for MP-2100 MSL cards)
- LS octet: BERT state (at port/TS/Bit level)- same as for MP-2100 MSL cards
- For MP-4100, LRS-102 OP-108/106 Links - 3 Octets
- MS octet: far-end PS type and state
- Middle octet: synchronization with far-end device
- LS octet: BERT state (at port/TS level) - same as for MP-2100 MSL cards
- MS octet:
Bit 7 6 5 4 3 2 1 0 LSB
|__| |__| |__| |__|
PS-A PS-A PS-B PS-B
PS Type PS State PS Type PS State
00=None 00=None
01=AC-DC 01=OK
10=DC 10=Fail
- Middle octet:
Bit 7 6 5 4 3 2 1 0 LSB
|__|
sync:
00 = not sync
01 = sync
10 = reserved
11 = reserved
Rest = reserved
"
::= { prtSInstEntry 15}
prtSTestMaskXp OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is an Expanded test mask of the prtSTestMask object.
The prtSTestMask object reached its maximum, being an Integer with 32 bits.
This object indicates which tests from the 'prtSTstCmdXP' list are
allowed for the selected port.
If a specific test is allowed, its respective bit will be SET
in the mask :
TEST BIT
----------- ---
local-loop 1
remote-loop 2
loc-and-rem-main-loops 3
remote-analog-loop 4
remote-digital-loop 5
rem-loop-on-ext-unit 6
bert 7
tone-injection 8
dlci local-loop 9
all dlci local-loop 10
dlci remote-loop 11
all dlci remote-loop 12
bert-and-rem-loop-on-rem-unit 13
rem-loop-on-rem-unit 14
block 15
backward-tone-inject 16
llb 17
rlb 18
ft1Enable 21
lbbd 22 --for 2B+D
lb1 23 --for B1
lb2 24 --for B2
llb-on-rem-unit 25
bert-on-rem-unit 26
bert-on-rem-and-llb-on-rem-unit 27
local-and-bert-on-rem-unit 28
local-loop-on-rem-unit 29
localBert 30 --towards IO ports
test-per-TS 31
csuLoopAndBert 32
dsuLoopAndBert 33
remoteOcuLoopAndBert 34
remoteCsuLoopAndBert 35
remoteDsuLoopAndBert 36
e.g : If the return value is 00000003 hex ->
Bits 1 & 2 are set -> the allowed tests are :
local-loop
remote-loop "
::= { prtSInstEntry 16}
prtSRdnStatus OBJECT-TYPE
SYNTAX INTEGER {
noRdn (1),
offline(2),
online (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Redundancy Status of this port.
noRdn - this port is not part of a Redundancy pair/group.
offline - this port is offline from Redundancy point of view.
online - this port is online from Redundancy point of view."
::= { prtSInstEntry 17}
prtSAlrTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The list of port agent alarms."
::= { statPrtGen 2 }
prtSAlrEntry OBJECT-TYPE
SYNTAX PrtSAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtSAlrSltIdx, prtSAlrPrtIdx, prtSAlrIdx}
::= { prtSAlrTable 1}
PrtSAlrEntry ::=
SEQUENCE {
prtSAlrSltIdx INTEGER,
prtSAlrPrtIdx Integer32,
prtSAlrIdx Integer32,
prtSAlrCodeDescription DisplayString,
prtSAlrCode Integer32,
prtSAlrSeverity INTEGER,
prtSAlrState INTEGER,
prtSAlrCounter Integer32,
prtSAlrMask INTEGER,
prtSAlrInvert INTEGER,
prtSAlrCardType INTEGER
}
prtSAlrIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify an entry in the alarm status table.
Users should use the get next function to read this table because
the indexes are not consecutive"
::= { prtSAlrEntry 1}
prtSAlrSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique identifier of the slot
where the card is inserted.
In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16)
are not valid.
For the Vmux2100 Main Board clA (3) is used."
::= { prtSAlrEntry 2}
prtSAlrPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique identifier of the port
the alarm applies to.
All the values are valid. No alarms exist for a port
which does not exist.
Valid valuesfor MP-2100/2200: exPrt1 (1) .. exPrt16 (16) ,
inPrt1 (101) .. inPrt48 (148),
IP Bundles.
For other products, see product's spec."
::= { prtSAlrEntry 3}
prtSAlrCodeDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is a full text description of the alarm.
The alarm description includes the following information:
alarm code, alarm text, alarm severity, Masked or Inverted
flag and counter."
::= { prtSAlrEntry 4}
prtSAlrCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A code identifying the alarm of an entry in the alarm status
table at port level."
::= { prtSAlrEntry 5 }
prtSAlrSeverity OBJECT-TYPE
SYNTAX INTEGER
{
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity of the alarm."
::= { prtSAlrEntry 6 }
prtSAlrState OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the alarm."
::= { prtSAlrEntry 7 }
prtSAlrCounter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A counter - how many times the alarm occured since last
clear operation.
ON and OFF Alarm will be counted separately."
::= { prtSAlrEntry 8 }
prtSAlrMask OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm mask : on/off."
::= { prtSAlrEntry 9 }
prtSAlrInvert OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm invert : on/off."
::= { prtSAlrEntry 10 }
prtSAlrCardType OBJECT-TYPE
SYNTAX INTEGER
{
--
-- General types
--
unknown (1),
empty (2),
--
-- Power Supply Modules
--
ps (17),
--
-- Cl Modules
--
cl1 (20),
cl1Clk (26), --CL1 with Station Clock (for LRS102)
-- VF cards of Megaplex
vf24T1 (62),
vf30E1 (63),
vf48T1 (64),
vf60E1 (65),
--
-- TDM Cards
--
vc8EandM (74),
vc8Fxo (75),
vc8Fxs (76),
vc16EandM (77),
vc16Fxo (78),
vc16Fxs (79),
ml8T1 (134),
ml8E1 (135),
hsr (156),
ls12 (159),
ls6n (180),
hsEthSwitch (224),
hsu12 (240),
hsu6 (241),
vc4Fxs (255),
vc4EandM (256),
vc4Fxo (257),
msl4E1W2 (261),
msl8E1W2 (263),
msl4E1W2Eth (264),
msl8E1W2Eth (265),
asmi54cE1AndEth (266), -- & LRS-102 (E1 & ETH)
asmi54cT1AndEth (267), -- & LRS-102 (T1 & ETH)
asmi54c (268), -- & LRS-102 (ETH only)
hs6N (271),
hs12N (272),
-- MP-4100 (and LRS-102) cards
clx1 (301),
clx1GbE (302),
clx1S155 (303),
clx1S155GbE (304),
ml8T1Eth (305),
ml8E1Eth (306),
op106cEth (307), --no external T1
op108cEth (308), --no external E1
op106cEthT1 (309), --with external T1 (used also by LRS-102)
op108cEthE1 (310), --with external E1 (used also by LRS-102)
op108cEthE1Unbal(311), --used only by LRS-102
mpw1 (312),
-- VFS cards of Megaplex
vfs24T1 (321),
vfs30E1 (322),
vfs48T1 (323), --2T1
vfs60E1 (324) --2E1
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the type of card installed
in the specific slot position. The enumeration is according
to mdlSInstCardType."
::= { prtSAlrEntry 11 }
--
-- Statistics of Ports
--
--statisPrtGen OBJECT IDENTIFIER ::= {statPrtGen 3}
--prtFrStatis OBJECT IDENTIFIER ::= {statisPrtGen 1}
--prtCrStatis OBJECT IDENTIFIER ::= {statisPrtGen 2}
--prtDlciStatis OBJECT IDENTIFIER ::= {statisPrtGen 3}
--prtT1Statis OBJECT IDENTIFIER ::= {statisPrtGen 4}
--prtFrStatis - Port Statistics for (FR) Frame Relay protocol
prtFrStatisTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtFrStatisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is applicable only for an active port running an
FR protocol ."
::= { prtFrStatis 1}
prtFrStatisEntry OBJECT-TYPE
SYNTAX PrtFrStatisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtFrStatisSltIdx, prtFrStatisPrtIdx, prtFrStatisInvIdx}
::= { prtFrStatisTable 1}
PrtFrStatisEntry ::=
SEQUENCE {
prtFrStatisSltIdx INTEGER,
prtFrStatisPrtIdx INTEGER,
prtFrStatisInvIdx INTEGER,
prtFrTimeElapsed Integer32,
prtFrRxTotalFrames Counter32,
prtFrTxTotalFrames Counter32,
prtFrRxTotalBytes Counter32,
prtFrTxTotalBytes Counter32,
prtFrRxMngFrames Counter32,
prtFrTxMngFrames Counter32,
prtFrRxDeFrames Counter32,
prtFrTxDeFrames Counter32,
prtFrRxDcrdCongDeFr Counter32,
prtFrTxDcrdCongDeFr Counter32,
prtFrRxDcrdCongAllFr Counter32,
prtFrTxDcrdCongAllFr Counter32,
prtFrRxFecn Counter32,
prtFrTxFecn Counter32,
prtFrRxBecn Counter32,
prtFrTxBecn Counter32,
prtFrRxBeViol Counter32,
prtFrTxBeViol Counter32,
prtFrRxBcViol Counter32,
prtFrTxBcViol Counter32
}
prtFrStatisSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
For stand-alone units this index will be notApplicable (255)."
::= { prtFrStatisEntry 1}
prtFrStatisPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number."
::= { prtFrStatisEntry 2}
prtFrStatisInvIdx OBJECT-TYPE
SYNTAX INTEGER
{
currentInv (1),
last (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Interval of 15 min. for which the following statistics
counters are applicable."
::= { prtFrStatisEntry 3}
prtFrTimeElapsed OBJECT-TYPE
SYNTAX Integer32 (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since the
beginning of the current error-measurement interval.
This object is applicable mainly for the current interval.
For other interval:
- if data is available: value will be 899.
- if data is not available: value will be 0."
::= { prtFrStatisEntry 4 }
prtFrRxTotalFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames received by this port during the
selected interval."
::= { prtFrStatisEntry 5 }
prtFrTxTotalFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames sent by this port during the
selected interval."
::= { prtFrStatisEntry 6 }
prtFrRxTotalBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of bytes received by this port during the
selected interval."
::= { prtFrStatisEntry 7 }
prtFrTxTotalBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of bytes sent by this port during the
selected interval."
::= { prtFrStatisEntry 8 }
prtFrRxMngFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The management number of frames received by this port
during the selected interval."
::= { prtFrStatisEntry 9 }
prtFrTxMngFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The management number of frames sent by this port during the
selected interval."
::= { prtFrStatisEntry 10 }
prtFrRxDeFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of De frames received by this port during the
selected interval."
::= { prtFrStatisEntry 11 }
prtFrTxDeFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of De frames sent by this port during the
selected interval."
::= { prtFrStatisEntry 12 }
prtFrRxDcrdCongDeFr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of De frames discarded due to congestion,
received by this port during the selected interval."
::= { prtFrStatisEntry 13 }
prtFrTxDcrdCongDeFr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of De frames discarded due to congestion,
sent by this port during the selected interval."
::= { prtFrStatisEntry 14 }
prtFrRxDcrdCongAllFr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"All the frames discarded due to congestion,
received by this port during the selected interval."
::= { prtFrStatisEntry 15 }
prtFrTxDcrdCongAllFr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"All the frames discarded due to congestion,
sent by this port during the selected interval."
::= { prtFrStatisEntry 16 }
prtFrRxFecn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames received by this port during the
selected interval, indicating forward congestion."
::= { prtFrStatisEntry 17 }
prtFrTxFecn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames sent by this port during the
selected interval, indicating forward congestion."
::= { prtFrStatisEntry 18 }
prtFrRxBecn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames received by this port during the
selected interval, indicating backward congestion."
::= { prtFrStatisEntry 19 }
prtFrTxBecn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames sent by this port during the
selected interval, indicating backward congestion."
::= { prtFrStatisEntry 20 }
prtFrRxBeViol OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of data frames received by this port during the
selected interval, exceeding the Burst Excess value."
::= { prtFrStatisEntry 21 }
prtFrTxBeViol OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of data frames sent by this port during the
selected interval, exceeding the Burst Excess value."
::= { prtFrStatisEntry 22 }
prtFrRxBcViol OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of data frames received by this port during the
selected interval, exceeding the Burst Committed value."
::= { prtFrStatisEntry 23 }
prtFrTxBcViol OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of data frames sent by this port during the
selected interval, exceeding the Burst Committed value."
::= { prtFrStatisEntry 24 }
--prtCrStatis - Port Statistics for (CR) Cell Relay protocol
prtCrStatisTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtCrStatisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is applicable only for an active port running a
CR protocol ."
::= { prtCrStatis 1}
prtCrStatisEntry OBJECT-TYPE
SYNTAX PrtCrStatisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtCrStatisSltIdx, prtCrStatisPrtIdx, prtCrStatisInvIdx}
::= { prtCrStatisTable 1}
PrtCrStatisEntry ::=
SEQUENCE {
prtCrStatisSltIdx INTEGER,
prtCrStatisPrtIdx INTEGER,
prtCrStatisInvIdx INTEGER,
prtCrTimeElapsed Integer32,
prtCrRxTotalCells Counter32,
prtCrTxTotalCells Counter32,
prtCrRxDataCells Counter32,
prtCrTxDataCells Counter32
}
prtCrStatisSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
For stand-alone units this index will be notApplicable (255)."
::= { prtCrStatisEntry 1}
prtCrStatisPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number."
::= { prtCrStatisEntry 2}
prtCrStatisInvIdx OBJECT-TYPE
SYNTAX INTEGER
{
currentInv (1),
last (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Interval of 15 min. for which the following statistics
counters are applicable."
::= { prtCrStatisEntry 3}
prtCrTimeElapsed OBJECT-TYPE
SYNTAX Integer32 (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since the
beginning of the current error-measurement interval.
This object is applicable mainly for the current interval.
For other interval:
- if data is available: value will be 899.
- if data is not available: value will be 0."
::= { prtCrStatisEntry 4 }
prtCrRxTotalCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells received by this port during the
selected interval."
::= { prtCrStatisEntry 5 }
prtCrTxTotalCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells sent by this port during the
selected interval."
::= { prtCrStatisEntry 6 }
prtCrRxDataCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Data Cells received by this port during the
selected interval."
::= { prtCrStatisEntry 7 }
prtCrTxDataCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Data Cells sent by this port during the
selected interval."
::= { prtCrStatisEntry 8 }
--prtDlciStatis - Port DLCI Statistics for FR, FR+ and CR protocol
prtDlciStatisTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtDlciStatisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is applicable only for an active port running an
FR, FR+ or CR protocol, with valid DLCIs ."
::= { prtDlciStatis 1}
prtDlciStatisEntry OBJECT-TYPE
SYNTAX PrtDlciStatisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtDlciSltIdx, prtDlciPrtIdx, prtDlciIdx}
::= { prtDlciStatisTable 1}
PrtDlciStatisEntry ::=
SEQUENCE {
prtDlciSltIdx INTEGER,
prtDlciPrtIdx INTEGER,
prtDlciIdx Integer32,
prtDlciRxDeFrames Counter32,
prtDlciTxDeFrames Counter32,
prtDlciRxDcrdCongDeFr Counter32,
prtDlciTxDcrdCongDeFr Counter32,
prtDlciRxDcrdCongAllFr Counter32,
prtDlciTxDcrdCongAllFr Counter32,
prtDlciTxFecn Counter32,
prtDlciTxBecn Counter32,
prtDlciRxBeViol Counter32,
prtDlciTxBeViol Counter32,
prtDlciRxBcViol Counter32,
prtDlciTxBcViol Counter32
}
prtDlciSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
For stand-alone units this index will be notApplicable (255)."
::= { prtDlciStatisEntry 1}
prtDlciPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number."
::= { prtDlciStatisEntry 2}
prtDlciIdx OBJECT-TYPE
SYNTAX Integer32 (1..991)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique DLCI index for each valid
DLCI (16..991). "
::= { prtDlciStatisEntry 3}
prtDlciRxDeFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of De frames received by this DLCI."
::= { prtDlciStatisEntry 4 }
prtDlciTxDeFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of De frames sent by this DLCI."
::= { prtDlciStatisEntry 5 }
prtDlciRxDcrdCongDeFr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of De frames discarded due to congestion,
received by this DLCI."
::= { prtDlciStatisEntry 6 }
prtDlciTxDcrdCongDeFr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of De frames discarded due to congestion,
sent by this DLCI."
::= { prtDlciStatisEntry 7 }
prtDlciRxDcrdCongAllFr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"All the frames discarded due to congestion,
received by this DLCI."
::= { prtDlciStatisEntry 8 }
prtDlciTxDcrdCongAllFr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"All the frames discarded due to congestion,
sent by this DLCI."
::= { prtDlciStatisEntry 9 }
prtDlciTxFecn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames sent by this DLCI, indicating forward
congestion."
::= { prtDlciStatisEntry 10 }
prtDlciTxBecn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames sent by this DLCI, indicating backward
congestion."
::= { prtDlciStatisEntry 11 }
prtDlciRxBeViol OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of data frames received by this DLCI, exceeding the
Burst Excess value."
::= { prtDlciStatisEntry 12 }
prtDlciTxBeViol OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of data frames sent by this DLCI, exceeding the Burst
Excess value."
::= { prtDlciStatisEntry 13 }
prtDlciRxBcViol OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of data frames received by this DLCI, exceeding the
Burst Committed value."
::= { prtDlciStatisEntry 14 }
prtDlciTxBcViol OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of data frames sent by this DLCI, exceeding the Burst
Committed value."
::= { prtDlciStatisEntry 15 }
--prtT1 Last FDL Message Table - Statistics
prtT1FdlMsgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtT1FdlMsgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is applicable for a T1 interface with 'esf'
LineType ."
::= { prtT1Statis 1}
prtT1FdlMsgEntry OBJECT-TYPE
SYNTAX PrtT1FdlMsgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtT1FdlMsgSltIdx, prtT1FdlMsgPrtIdx, prtT1FdlMsgFdlTxRx}
::= { prtT1FdlMsgTable 1}
PrtT1FdlMsgEntry ::=
SEQUENCE {
prtT1FdlMsgSltIdx INTEGER,
prtT1FdlMsgPrtIdx INTEGER,
prtT1FdlMsgFdlTxRx INTEGER,
prtT1FdlMsg OCTET STRING
}
prtT1FdlMsgSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= { prtT1FdlMsgEntry 1}
prtT1FdlMsgPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
MTML-1/T1 modules have just one external interface."
::= { prtT1FdlMsgEntry 2}
prtT1FdlMsgFdlTxRx OBJECT-TYPE
SYNTAX INTEGER
{
tx (1),
rx (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Fdl tx/rx reference of the Fdl message."
::= { prtT1FdlMsgEntry 3}
prtT1FdlMsg OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"FDL message."
::= { prtT1FdlMsgEntry 4}
--
-- Extension of the Time Slot Config Table of ML ports
--
-- Time Slot is split to 8 Bits
prtExTsSplitTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExTsSplitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry, except prtExTsBitTest that will be
written directly to the Active Configuration."
::= {cnfgPrtGen 1}
prtExTsSplitEntry OBJECT-TYPE
SYNTAX PrtExTsSplitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExTsCnfgIdx, prtExTsSltIdx, prtExTsPrtIdx,
prtExTsIdx, prtExTsBit}
::= { prtExTsSplitTable 1}
PrtExTsSplitEntry ::=
SEQUENCE {
prtExTsCnfgIdx Integer32,
prtExTsSltIdx INTEGER,
prtExTsPrtIdx Integer32,
prtExTsIdx Integer32,
prtExTsBit Integer32,
prtExTsIConSlot INTEGER,
prtExTsIConPrt Integer32,
prtExTsBitTest INTEGER,
prtExTsTxSignaling OCTET STRING,
prtExTsRxSignaling OCTET STRING,
prtExTsTxIoSignaling OCTET STRING,
prtExTsRxIoSignaling OCTET STRING
}
prtExTsCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtExTsSplitEntry 1}
prtExTsSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
notApplicable - for stand-alone units."
::= { prtExTsSplitEntry 2}
prtExTsPrtIdx OBJECT-TYPE
SYNTAX Integer32
-- For MP:
-- {
-- exPrt1 (1),
-- inPrt1 (101)
-- }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
Most ML cards have only one external interface.
inPrt1 - for MTML-H/E1 cards.
For other products' index see their specification."
::= { prtExTsSplitEntry 3}
prtExTsIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique time slot position.
The valid time slots are:
1..24 for T1 Card and
1..31 for E1 interface.
In G732S-E1 lines, time slot 16 is not valid for data,
it is dedicated to multiframe synchronization bits
and voice signaling."
::= { prtExTsSplitEntry 4}
prtExTsBit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique Bit within the time slot.
The valid Bits are: 1..8.
255=NA."
::= { prtExTsSplitEntry 5}
prtExTsIConSlot OBJECT-TYPE
SYNTAX INTEGER
{
noConnect (2),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the specified time slot is
connected/routed internally in the Agent and to which card
it is connected.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
notApplicable - for stand-alone units."
::= {prtExTsSplitEntry 6}
prtExTsIConPrt OBJECT-TYPE
SYNTAX Integer32
-- For MP:
-- {
-- exPrt1 (1) ,
-- exPrt2 (2) ,
-- exPrt3 (3) ,
-- exPrt4 (4) ,
-- exPrt5 (5) ,
-- exPrt6 (6) ,
-- exPrt7 (7) ,
-- exPrt8 (8) ,
-- exPrt9 (9) ,
-- exPrt10 (10) ,
-- exPrt11 (11) ,
-- exPrt12 (12) ,
--
-- noConnect (100),
--
-- inPrt1 (101) ,
-- inPrt2 (102) ,
-- inPrt3 (103) ,
-- inPrt4 (104) ,
-- inPrt5 (105) ,
-- inPrt6 (106) ,
-- inPrt7 (107) ,
-- inPrt8 (108) ,
-- inPrt9 (109) ,
-- inPrt10 (110) ,
-- inPrt11 (111) ,
-- inPrt12 (112)
-- }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the internally (In Mux)
connected/routed port.
For other products' index see their specification."
::= {prtExTsSplitEntry 7}
prtExTsBitTest OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
remoteBert (8),
localBert (30),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a test to be activated on the selected Bit.
It is applicable only when prtExPh1MlTsTest=split(254).
none - no test is applied for the selected Bit.
notApplicable - when prtExPh1MlTsTest is NOT split(254)."
::= { prtExTsSplitEntry 8}
prtExTsTxSignaling OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link - Tx Signaling per TS, for TSs having TS Type=Voice
(agnTsType=voice(2)).
It monitors what is sent to Link for the selected TS,
for A,B,C,D Signaling Bits.
Bit 1= LSB
Bit 8= MSB
Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA"
::= { prtExTsSplitEntry 9}
prtExTsRxSignaling OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link - Rx Signaling per TS, for TSs having TS Type=Voice
(agnTsType=voice(2)).
It monitors what is received from Link for the selected TS,
for A,B,C,D Signaling Bits.
Bit 1= LSB
Bit 8= MSB
Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA"
::= { prtExTsSplitEntry 10}
prtExTsTxIoSignaling OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IO - Tx Signaling per TS, for TSs having TS Type=Voice
(agnTsType=voice(2)).
It monitors what is sent to IO port for the selected TS,
for A,B,C,D Signaling Bits.
Bit 1= LSB
Bit 8= MSB
Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA"
::= { prtExTsSplitEntry 11}
prtExTsRxIoSignaling OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IO - Rx Signaling per TS, for TSs having TS Type=Voice
(agnTsType=voice(2)).
It monitors what is received from IO port for the selected TS,
for A,B,C,D Signaling Bits.
Bit 1= LSB
Bit 8= MSB
Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA"
::= { prtExTsSplitEntry 12}
prtCnfgAgenda OBJECT IDENTIFIER ::= {cnfgPrtGen 2}
prtAgendaBehaviourTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtAgendaBehaviourEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { prtCnfgAgenda 1}
prtAgendaBehaviourEntry OBJECT-TYPE
SYNTAX PrtAgendaBehaviourEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtAgendaBehaviourCnfgIdx, prtAgendaBehaviourSltIdx,
prtAgendaBehaviourPrtIdx }
::= { prtAgendaBehaviourTable 1}
PrtAgendaBehaviourEntry ::=
SEQUENCE {
prtAgendaBehaviourCnfgIdx Integer32,
prtAgendaBehaviourSltIdx Integer32,
prtAgendaBehaviourPrtIdx Integer32,
prtAgendaBehaviourOnOff INTEGER
}
prtAgendaBehaviourCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtAgendaBehaviourEntry 1}
prtAgendaBehaviourSltIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter should be:
- slot number for MX3000
- 255 = N/A for MX300/30. "
::= { prtAgendaBehaviourEntry 2 }
prtAgendaBehaviourPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter should be:
- port number for MX300/30
- 100 = N/A for MX3000. "
::= { prtAgendaBehaviourEntry 3 }
prtAgendaBehaviourOnOff OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this command to on(3) enables the agenda function
at module (3000) or port (300/30) level."
DEFVAL { off }
::= { prtAgendaBehaviourEntry 4 }
prtCnfgAgendaTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtCnfgAgendaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table allows the user to schedule the time a session
is active per week basis."
::= { prtCnfgAgenda 2}
prtCnfgAgendaEntry OBJECT-TYPE
SYNTAX PrtCnfgAgendaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtCnfgAgendaCnfgIdx, prtCnfgAgendaSltIdx,
prtCnfgAgendaPrtIdx, prtCnfgAgendaDayIdx, prtCnfgAgendaSesId }
::= { prtCnfgAgendaTable 1}
PrtCnfgAgendaEntry ::=
SEQUENCE {
prtCnfgAgendaCnfgIdx Integer32,
prtCnfgAgendaSltIdx Integer32,
prtCnfgAgendaPrtIdx Integer32,
prtCnfgAgendaDayIdx INTEGER,
prtCnfgAgendaSesId Integer32,
prtCnfgAgendaFrom Integer32,
prtCnfgAgendaTo Integer32
}
prtCnfgAgendaCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtCnfgAgendaEntry 1}
prtCnfgAgendaSltIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is equal to:
-slot number for MX3000
-255 = N/A for MX300/30"
::= { prtCnfgAgendaEntry 2}
prtCnfgAgendaPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is equal to:
- port number for MX300/30
- port number for MX3000. For example 1-4 in MHS-4 cards.
- 100 = N/A for MX3000 when not used."
::= { prtCnfgAgendaEntry 3}
prtCnfgAgendaDayIdx OBJECT-TYPE
SYNTAX INTEGER {
monday (1),
tuesday (2),
wednesday(3),
thursday (4),
friday (5),
saturday (6),
sunday (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute for which day of the week this row applies."
::= { prtCnfgAgendaEntry 4 }
prtCnfgAgendaSesId OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user may define 4 different active intervals per day."
::= { prtCnfgAgendaEntry 5 }
prtCnfgAgendaFrom OBJECT-TYPE
SYNTAX Integer32 (0..86400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Start from time interval in seconds."
DEFVAL {86400}
::= { prtCnfgAgendaEntry 6 }
prtCnfgAgendaTo OBJECT-TYPE
SYNTAX Integer32 (0..86400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"To time interval in seconds."
DEFVAL {86400}
::= { prtCnfgAgendaEntry 7 }
-- General Port Configuration parameters
prtGenCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtGenCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table allows the user to configure general
port parameters."
::= {cnfgPrtGen 3}
prtGenCnfgEntry OBJECT-TYPE
SYNTAX PrtGenCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtGenCnfgIdx, prtGenCnfgSltIdx, prtGenCnfgPrtIdx }
::= { prtGenCnfgTable 1}
PrtGenCnfgEntry ::=
SEQUENCE {
prtGenCnfgIdx Integer32,
prtGenCnfgSltIdx INTEGER,
prtGenCnfgPrtIdx Integer32,
prtGenCnfgLinkToSlot INTEGER,
prtGenCnfgLinkToPort Integer32,
prtGenCnfgPortId Integer32,
prtGenCnfgBusConnection INTEGER,
prtGenCnfgInbandMng INTEGER,
prtGenCnfgInbandMngRoutProt INTEGER,
prtGenCnfgProtectionMode INTEGER, --not used
prtGenCnfgConnect INTEGER,
prtGenCnfgSignalingType INTEGER
}
prtGenCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg.
The write operation is valid only to the TmpCnfg."
::= { prtGenCnfgEntry 1}
prtGenCnfgSltIdx OBJECT-TYPE
SYNTAX INTEGER
{ clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted."
::= { prtGenCnfgEntry 2}
prtGenCnfgPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique external or internal port number.
For MP:
exPrt1 (1) .. exPrt16 (16) ,
notApplicable(100),
inPrt1 (101) .. inPrt84 (184) "
::= { prtGenCnfgEntry 3}
prtGenCnfgLinkToSlot OBJECT-TYPE
SYNTAX INTEGER
{
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the slot of the ML card to which
the IO port is mapped."
::= { prtGenCnfgEntry 4}
prtGenCnfgLinkToPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the port in the prtGenCnfgLinkToSlot of
the ML card to which the IO port is mapped.
For MP:
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103) ,
inPrt4 (104) ,
inPrt5 (105) ,
inPrt6 (106) ,
inPrt7 (107) ,
inPrt8 (108) ,
inPrt9 (109),
inPrt10 (110),
inPrt11 (111),
inPrt12 (112),
inPrt13 (113),
inPrt14 (114),
inPrt15 (115),
inPrt16 (116),
inPrt17 (117),
inPrt18 (118),
inPrt19 (119),
inPrt20 (120),
inPrt21 (121),
inPrt22 (122),
inPrt23 (123),
inPrt24 (124),
inPrt25 (125),
inPrt26 (126),
inPrt27 (127),
inPrt28 (128),
inPrt29 (129),
inPrt30 (130),
inPrt31 (131),
inPrt32 (132),
inPrt33 (133),
inPrt34 (134),
inPrt35 (135),
inPrt36 (136),
inPrt37 (137),
inPrt38 (138),
inPrt39 (139),
inPrt40 (140),
inPrt41 (141),
inPrt42 (142),
inPrt43 (143),
inPrt44 (144),
inPrt45 (145),
inPrt46 (146),
inPrt47 (147),
inPrt48 (148),
inPrt49 (149),
inPrt50 (150),
inPrt51 (151),
inPrt52 (152),
inPrt53 (153),
inPrt54 (154),
inPrt55 (155),
inPrt56 (156),
inPrt57 (157),
inPrt58 (158),
inPrt59 (159),
inPrt60 (160),
inPrt61 (161),
inPrt62 (162),
inPrt63 (163),
inPrt64 (164),
inPrt65 (165),
inPrt66 (166),
inPrt67 (167),
inPrt68 (168),
inPrt69 (169),
inPrt70 (170),
inPrt71 (171),
inPrt72 (172),
inPrt73 (173),
inPrt74 (174),
inPrt75 (175),
inPrt76 (176),
inPrt77 (177),
inPrt78 (178),
inPrt79 (179),
inPrt80 (180),
inPrt81 (181),
inPrt82 (182),
inPrt83 (183),
inPrt84 (184),
notApplicable (255) "
::= { prtGenCnfgEntry 5}
prtGenCnfgPortId OBJECT-TYPE
SYNTAX Integer32 (0..16777215)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IO Port Id for V5.1 use.
This object is applicable only for part of the PSTN and ISDN IO ports.
Generally, 0 is a valid value.
Nevertheless, for ports that do not support this object, the value
will be: notApplicable= 0"
::= { prtGenCnfgEntry 6}
prtGenCnfgBusConnection OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
partial (2),
full (3),
partialCD (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the support of the card regarding Bus Connection.
Same value for all ports of the card.
partial = 2 Buses (AB)
full = 4 Buses (ABCD)
partial CD = 2 Buses CD
Actually the support depends on the card's HW. But, since CL has to assign
data on Buses even when the card is not installed, this object has to be
configured.
If the actual card installed will not match the value configured, an Alarm
will be issued."
::= { prtGenCnfgEntry 7}
prtGenCnfgInbandMng OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether Inband Management is used over the
link."
::= {prtGenCnfgEntry 8}
prtGenCnfgInbandMngRoutProt OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
rip2 (2),
proprietaryRip (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Inband Mng Routing Protocol of
the port."
::= {prtGenCnfgEntry 9}
prtGenCnfgProtectionMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
secondary (2),
primary (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Protection Mode of the port.
notApplicable- when Bus Protection Point=No.
For VC-4/Omni card this object is supported RO."
::= {prtGenCnfgEntry 10}
prtGenCnfgConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the port should be considered in
any of the mux algorithms."
::= {prtGenCnfgEntry 11}
prtGenCnfgSignalingType OBJECT-TYPE
SYNTAX INTEGER
{
legacy (3),
abcd (4),
none (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object selects the Type of Signaling used by the port."
::= {prtGenCnfgEntry 12}
--
-- Compressed information.
--
-- Specially for RadView management station
--
prtCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { cmprPrtGen 1 }
prtCmprEntry OBJECT-TYPE
SYNTAX PrtCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtCmprTypIdx, prtCmprCnfgIdx,prtCmprVersion,prtCmprSltIdx,prtCmprPrtIdx}
::= {prtCmprTable 1}
PrtCmprEntry ::=
SEQUENCE {
prtCmprTypIdx Integer32,
prtCmprCnfgIdx Integer32,
prtCmprVersion Integer32,
prtCmprSltIdx INTEGER,
prtCmprPrtIdx Integer32,
prtCmprObj OCTET STRING,
prtCmprStatisticObj OCTET STRING
}
prtCmprTypIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Type of the Compressed being
referred."
::= { prtCmprEntry 1}
prtCmprCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the configuration to which the
Compressed information is related."
::= { prtCmprEntry 2}
prtCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal format of
the Compressed data"
::= { prtCmprEntry 3}
prtCmprSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number of the slot position
where the card is inserted.
In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16)
are not valid."
::= { prtCmprEntry 4}
prtCmprPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique identifier of the port
the compressed information relates to.
Valid values: exPrt1 (1) .. exPrt16 (16) ,
inPrt1 (101) .. inPrt48 (148)."
::= { prtCmprEntry 5}
prtCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { prtCmprEntry 6}
prtCmprStatisticObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is the compressed statistics information itself."
::= { prtCmprEntry 7}
-- Compressed Dlci table in the Port level
-- The only way of reading this table is by the command 'GET NEXT'
prtDlciCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtDlciCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { cmprPrtGen 2 }
prtDlciCmprEntry OBJECT-TYPE
SYNTAX PrtDlciCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtDlciCmprCnfgIdx,prtDlciCmprVersion,
prtDlciCmprSltIdx,prtDlciCmprPrtIdx,prtDlciCmprDlciIdx}
::= {prtDlciCmprTable 1}
PrtDlciCmprEntry ::=
SEQUENCE {
prtDlciCmprCnfgIdx Integer32,
prtDlciCmprVersion Integer32,
prtDlciCmprSltIdx INTEGER,
prtDlciCmprPrtIdx INTEGER,
prtDlciCmprDlciIdx Integer32,
prtDlciCmprObj OCTET STRING
}
prtDlciCmprCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the configuration to which the
Compressed information is related."
::= { prtDlciCmprEntry 1}
prtDlciCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal format of
the Compressed data"
::= { prtDlciCmprEntry 2}
prtDlciCmprSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number of the slot position
where the module is inserted.
In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16)
are not valid."
::= { prtDlciCmprEntry 3}
prtDlciCmprPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103) ,
inPrt4 (104) ,
inPrt5 (105) ,
inPrt6 (106) ,
inPrt7 (107) ,
inPrt8 (108) ,
inPrt9 (109) ,
inPrt10 (110) ,
inPrt11 (111) ,
inPrt12 (112)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique identifier of the port
the compressed information relates to.
All the values are valid."
::= { prtDlciCmprEntry 4}
prtDlciCmprDlciIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique identifier of the Dlci
the compressed information relates to.
The values are between 16 - 991."
::= { prtDlciCmprEntry 5}
prtDlciCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { prtDlciCmprEntry 6}
-- Compressed Alarm table in the Port level
-- The only way of reading this table is by the command 'GET NEXT'
prtAlarmsCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtAlarmsCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= {cmprPrtGen 3}
prtAlarmsCmprEntry OBJECT-TYPE
SYNTAX PrtAlarmsCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtAlarmsCmprVersion,prtAlarmsCmprAlarmSlot,
prtAlarmsCmprAlarmPort,prtAlarmsCmprAlarmIdx}
::= {prtAlarmsCmprTable 1}
PrtAlarmsCmprEntry ::=
SEQUENCE {
prtAlarmsCmprVersion Integer32,
prtAlarmsCmprAlarmSlot Integer32,
prtAlarmsCmprAlarmPort Integer32,
prtAlarmsCmprAlarmIdx Integer32,
prtAlarmsCmprObj OCTET STRING
}
prtAlarmsCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal format of
the Compressed data"
::= { prtAlarmsCmprEntry 1}
prtAlarmsCmprAlarmSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the desired slot position.
In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16)
are not valid.
For Stand-alone units, notApplicable(255) will appear."
::= { prtAlarmsCmprEntry 2}
prtAlarmsCmprAlarmPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique identifier of the port
the alarm applies to.
All the values are valid. No alarms exist for a non-existing
port. IP Bundles are considered a port too, for this matter."
::= { prtAlarmsCmprEntry 3}
prtAlarmsCmprAlarmIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify an entry in the alarm status table
of the agent."
::= { prtAlarmsCmprEntry 4}
prtAlarmsCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { prtAlarmsCmprEntry 5}
--
-- Specific port status for each module Type
-- *****************************************
--
-- Megaplex?000/?004 port specific status for HS(TDM) modules
-- HS-2,HS-3,HS-Q, HS-6, HS-12
prtSExHsfStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSExHsfStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= {statPrtMux 6}
prtSExHsfStatEntry OBJECT-TYPE
SYNTAX PrtSExHsfStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtSExHsfSltIdx, prtSExHsfPrtIdx }
::= {prtSExHsfStatTable 1}
PrtSExHsfStatEntry ::=
SEQUENCE {
prtSExHsfSltIdx INTEGER,
prtSExHsfPrtIdx INTEGER,
prtSExHsfInterfaceTyp INTEGER,
prtSExHsfRts INTEGER
}
prtSExHsfSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid."
::= { prtSExHsfStatEntry 1}
prtSExHsfPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
exPrt11 (11) ,
exPrt12 (12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number. "
::= { prtSExHsfStatEntry 2}
prtSExHsfInterfaceTyp OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
v35 (2),
rs422 (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique interface type of a
selected port."
::= { prtSExHsfStatEntry 3}
prtSExHsfRts OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
notActive (2),
active (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique RTS control signal state."
::= { prtSExHsfStatEntry 4}
-- ISDN Port Status
prtIsdnStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtIsdnStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains ISDN Statistics parameters that do not appear
in the standard MIBs or for agents that don't support the standard Index
of Call Set Up Time."
::= { statPrtMux 16 }
prtIsdnStatusEntry OBJECT-TYPE
SYNTAX PrtIsdnStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries for ISDN Statistics parameters that do not appear in the standard MIBs
or for agents that don't support the standard Index of Call Set Up Time."
INDEX { ifIndex }
::= { prtIsdnStatusTable 1 }
PrtIsdnStatusEntry ::=
SEQUENCE {
prtIsdnStatusDspMode INTEGER,
prtIsdnStatusCallState INTEGER,
prtIsdnStatusCallingNumber DisplayString,
prtIsdnStatusCalledNumber DisplayString,
prtIsdnStatusCalledIP IpAddress,
prtIsdnStatusCallDirection INTEGER
}
prtIsdnStatusDspMode OBJECT-TYPE
SYNTAX INTEGER
{
voice (2),
idle (3),
fax (4),
vbd (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DSP can be in one of the following Modes:
Voice, Idle, Fax, Voice Band Data (VBD)- Modem."
::= { prtIsdnStatusEntry 1 }
prtIsdnStatusCallState OBJECT-TYPE
SYNTAX INTEGER
{
present (2),
overlapReceive (3),
incoming (4),
receive (5),
initiated (6),
overlapSend (7),
outGoingProceed (8),
callDeliver (9),
active (10),
disconnectIndicate (11),
releaseRequest (12),
disconnectReq (13),
notActive (14)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state that the current call is in."
::= { prtIsdnStatusEntry 2 }
prtIsdnStatusCallingNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the local Number (ISDN Address) associated with this entry."
::= { prtIsdnStatusEntry 3 }
prtIsdnStatusCalledNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the remote Number (ISDN Address) associated with this entry."
::= { prtIsdnStatusEntry 4 }
prtIsdnStatusCalledIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the remote IP Address associated with this entry."
::= { prtIsdnStatusEntry 5 }
prtIsdnStatusCallDirection OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
incoming (2),
outgoing (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Attribute indicating the Direction of the Call.
The value of notApplicable will be used for example when
prtIsdnStatusCallState = notActive(14)."
::= { prtIsdnStatusEntry 6 }
cnfgMdlMux OBJECT IDENTIFIER ::= {mdlMux 1}
mdlPbxFramerCnfg OBJECT IDENTIFIER ::= {cnfgMdlMux 1}
mdlPbxFramerCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlPbxFramerCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains parameters relevant to a module belonging to
a digital voice system, except mdlPbxFraEnhEcho which is relevant
also for analog cards."
::= {mdlPbxFramerCnfg 1}
mdlPbxFramerCnfgEntry OBJECT-TYPE
SYNTAX MdlPbxFramerCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mdlPbxFraCnfgIdx, mdlPbxFraSltIdx }
::= {mdlPbxFramerCnfgTable 1}
MdlPbxFramerCnfgEntry ::=
SEQUENCE {
mdlPbxFraCnfgIdx Integer32,
mdlPbxFraSltIdx INTEGER,
mdlPbxFraEnhEcho INTEGER,
mdlPbxFraTSGroupAss INTEGER,
mdlPbxFraSignalMode INTEGER,
mdlPbxFraSignalVector OCTET STRING,
mdlPbxFraSignalMask OCTET STRING,
mdlPbxFraFramerSlot INTEGER,
mdlPbxFraSignaling INTEGER,
mdlPbxFraTransSigTs Integer32
}
mdlPbxFraCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
-- DEFVAL {1}
::= { mdlPbxFramerCnfgEntry 1}
mdlPbxFraSltIdx OBJECT-TYPE
SYNTAX INTEGER{ io1(5), io2(6), io3(7), io4(8), io5(9),
io6(10), io7(11), io8(12), io9(13), io10(14),
io11(15), io12(16) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot relevant to this module."
::= { mdlPbxFramerCnfgEntry 2}
mdlPbxFraEnhEcho OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1) ,
disabled(2),
ms16(3),
ms32(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Refers to external ports of an analogue module
and to the internal ports of the other mvc4 types
of modules.
ms16(3) means that the four voice ports have enhanced
echo of 16ms.
ms32(4) means that the two first ports have enhanced
echo of 32 ms while the last two ports have no
enhanced echo."
::= { mdlPbxFramerCnfgEntry 3}
mdlPbxFraTSGroupAss OBJECT-TYPE
SYNTAX INTEGER{ group1(1), group2(2), group3(3), group4(4),
group5(5), group6(6), group7(7), group8(8),
notApplicable(255) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In case of T1 modules:
group1=(1,2,3,4), ...., group6=(21,22,23,24)
while in case of E1 modules:
- If prtExPh1MlLineType=g732sE1 or g732sE1CRC:
group1=(1,2,3,4),..,group4=(13,14,15,17),
group5=(18,19,20,21),...,group7=(26,27,28,29)
group8=(30,31).
- If prtExPh1MlLineType=g732nE1 or g732nE1CRC:
group1=(1,2,3,4),..,group4=(13,14,15,16),
group5=(17,18,19,20),...,group7=(25,26,27,28)
group8=(29,30,31)."
::= { mdlPbxFramerCnfgEntry 4}
mdlPbxFraSignalMode OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1),
tieTrunk(2),
tieInvert(3),
casTrans(4),
userDefined(5),
ccsTrans(6),
noSignaling(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Refers to the signaling mode of the Framer module.
tieTrunk(2), tieInvert(3), casTrans(4) are standard
coding of the signaling protocol.
casTrans(4) is Channel Associated Signaling (the signaling is within the
channels time slot).
ccsTrans(6) is Transparent Common Channel Signaling (the signaling is not within
the channels time slot - a TS for signaling is used).
userDefined(5) allows the user to define the signaling
protocol he wants. In this case, the next two MIB fields
are relevant."
DEFVAL { casTrans }
::= { mdlPbxFramerCnfgEntry 5}
mdlPbxFraSignalVector OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In the case of mdlPbxFraSignalMode = userDefined(5), this
field defines the A,B,C Bits. D bit is supplied for future
versions.
Bit 1 = Bit A ON Hook - Local
Bit 2 = Bit B ON Hook - Local
Bit 3 = Bit C ON Hook - Local
Bit 4 = Bit D ON Hook - Local
Bit 5 = Bit A OFF Hook - Local
Bit 6 = Bit B OFF Hook - Local
Bit 7 = Bit C OFF Hook - Local
Bit 8 = Bit D OFF Hook - Local
Bit 9 = Bit A ON Hook - Remote
Bit 10 = Bit B ON Hook - Remote
Bit 11 = Bit C ON Hook - Remote
Bit 12 = Bit D ON Hook - Remote
Bit 13 = Bit A OFF Hook - Remote
Bit 14 = Bit B OFF Hook - Remote
Bit 15 = Bit C OFF Hook - Remote
Bit 16 = Bit D OFF Hook - Remote
In conjunction with the Mask, mdlPbxFraSignalMask, it is
possible to compute the signal mode."
DEFVAL { '0000'H}
::= { mdlPbxFramerCnfgEntry 6}
mdlPbxFraSignalMask OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In the case of mdlPbxFraSignalMode = userDefined(5), this
field defines the 'don't care' A,B,C Bits. D bit is supplied
for future versions.
Bit 1 = Bit A ON Hook - Local
Bit 2 = Bit B ON Hook - Local
Bit 3 = Bit C ON Hook - Local
Bit 4 = Bit D ON Hook - Local
Bit 5 = Bit A OFF Hook - Local
Bit 6 = Bit B OFF Hook - Local
Bit 7 = Bit C OFF Hook - Local
Bit 8 = Bit D OFF Hook - Local
Bit 9 = Bit A ON Hook - Remote
Bit 10 = Bit B ON Hook - Remote
Bit 11 = Bit C ON Hook - Remote
Bit 12 = Bit D ON Hook - Remote
Bit 13 = Bit A OFF Hook - Remote
Bit 14 = Bit B OFF Hook - Remote
Bit 15 = Bit C OFF Hook - Remote
Bit 16 = Bit D OFF Hook - Remote."
DEFVAL { 'ffff'H }
::= { mdlPbxFramerCnfgEntry 7}
mdlPbxFraFramerSlot OBJECT-TYPE
SYNTAX INTEGER { io1(5), io2(6), io3(7), io4(8), io5(9),
io6(10), io7(11), io8(12), io9(13), io10(14),
io11(15), io12(16) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Slot where is sitting the Framer."
::= { mdlPbxFramerCnfgEntry 8}
mdlPbxFraSignaling OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
endToEnd (2),
localTermination(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Signaling - describes the way the signaling ABCD bits pass from the
local extension to the remote extension and vice-versa.
endToEnd = the signaling ABCD bits pass without change from local to
remote extension.
localTermination = the signaling ABCD bits received from the local extension
are translated to different ON Hook/OFF Hook bit values and then
passed to remote extension. This is relevant when the Local
and Remote ON Hook/OFF Hook values are different."
DEFVAL { endToEnd }
::= { mdlPbxFramerCnfgEntry 9}
mdlPbxFraTransSigTs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the Time Slot that is used for Transparent CCS signaling.
The values of this TS are 1-24 for T1 & 1-31 for E1.
The default for E1 is 16 & for T1 it is 24. If no signaling is used then
the TS should be 255 (None)."
::= { mdlPbxFramerCnfgEntry 10}
--Protected IP Adresses list for ML-IP cards of MP-2100/4 and MP-2200
--for IP Ring Mode
mdlProtIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlProtIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains Protected IP Addresses for ML-IP cards
when working in IP Ring Mode."
::= {cnfgMdlMux 2}
mdlProtIpEntry OBJECT-TYPE
SYNTAX MdlProtIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mdlProtIpCnfgIdx, mdlProtIpSlotIdx, mdlProtIpAddress}
::= {mdlProtIpTable 1}
MdlProtIpEntry ::=
SEQUENCE {
mdlProtIpCnfgIdx Integer32,
mdlProtIpSlotIdx INTEGER,
mdlProtIpAddress IpAddress,
mdlProtIpRowStatus RowStatus
}
mdlProtIpCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg being accessed.
Idx 255 relates to the TmpCnfg.
For Agents having several configuration, Write operation is
allowed only to the Temporary Configuration."
::= { mdlProtIpEntry 1}
mdlProtIpSlotIdx OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted.
In the 2104 Unit the entries io6(10)..io16) are not valid."
::= { mdlProtIpEntry 2}
mdlProtIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Protected IP address."
::= { mdlProtIpEntry 3 }
mdlProtIpRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter allows creating/deleting entries of this table."
::= { mdlProtIpEntry 4 }
statMdlMux OBJECT IDENTIFIER ::= {mdlMux 2}
--
-- Card status table
--
mdlStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { statMdlMux 1 }
mdlStatEntry OBJECT-TYPE
SYNTAX MdlStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mdlStatSltIdx }
::= { mdlStatTable 1}
MdlStatEntry ::=
SEQUENCE {
mdlStatSltIdx INTEGER,
mdlStatHostIP IpAddress,
mdlStatHostMask IpAddress,
mdlStatDefaultGateway IpAddress
}
mdlStatSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify a slot position in the mux.
In the 2104 Unit the entries psB(2),clB(4),io6(10)..io12(16)
are not valid."
::= { mdlStatEntry 1}
mdlStatHostIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The host interface IP address when DHCP Client=Yes.
This object is relevant only when DHCP Client=Yes "
::= { mdlStatEntry 2 }
mdlStatHostMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The host interface subnet mask when DHCP Client=Yes.
This object is relevant only when DHCP Client=Yes "
::= { mdlStatEntry 3 }
mdlStatDefaultGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Default Gateway's IP Address when DHCP Client=Yes.
This object is relevant only when DHCP Client=Yes "
::= { mdlStatEntry 4 }
--
-- Specific port config for each module Type
-- *****************************************
--
-- MPCL.1 configuration parameters
--
--prtExClCnfgTable OBJECT IDENTIFIER ::= {prtClCnfg 1}
-- prtInClInbandTable OBJECT IDENTIFIER ::= {prtClCnfg 2}
prtExClCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExClCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= {prtClCnfg 1}
prtExClCnfgEntry OBJECT-TYPE
SYNTAX PrtExClCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"All the entries at this table are identical (have the same
value) for all the configurations (1..100) except the
TmpCnfg.
The write operation into the Table Objects is valid only
to the TmpCnfg entry."
INDEX {prtExClCnfgIdx, prtExClSltIdx, prtExClPrtIdx }
::= { prtExClCnfgTable 1}
PrtExClCnfgEntry ::=
SEQUENCE {
prtExClCnfgIdx Integer32,
prtExClSltIdx INTEGER,
prtExClPrtIdx INTEGER,
prtExClUsage INTEGER,
prtExClRate INTEGER,
prtExClDataBits INTEGER,
prtExClParity INTEGER,
prtExClStopBits INTEGER,
prtExClRoutingProtocol INTEGER,
prtExClEnabled INTEGER
}
prtExClCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg."
::= { prtExClCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExClSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
clA (3),
clB (4),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted. Because the second Cl is only for
redundancy, all the parameters are identical in the two
modules, i.e. change of any parameter in one module will
change automatically the value of the other module..
In the ?004 Unit the entry clB(4) is not valid."
::= { prtExClCnfgEntry 2}
prtExClPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number. "
::= { prtExClCnfgEntry 3}
prtExClUsage OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
noUse (2),
nmsSlip (3),
nmsPpp (4),
muxSlip (5),
muxPpp (6),
terminal(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates what is the usage of the port."
::= { prtExClCnfgEntry 4}
prtExClRate OBJECT-TYPE
SYNTAX INTEGER
{
r300Bps (1),
r1200Bps (2),
r2400Bps (3),
r4800Bps (4),
r9600Bps (5),
r19200Bps (6),
r38400Bps (7),
r57600Bps (8),
r115200Bps (9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the operation rate of the port."
::= { prtExClCnfgEntry 5}
prtExClDataBits OBJECT-TYPE
SYNTAX INTEGER
{
dataBits7Bits (1),
dataBits8Bits (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the number of data bits in async
frame"
::= { prtExClCnfgEntry 6}
prtExClParity OBJECT-TYPE
SYNTAX INTEGER
{
odd (1),
even (2),
none (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates if the parity operation mode in
async frame"
::= { prtExClCnfgEntry 7}
prtExClStopBits OBJECT-TYPE
SYNTAX INTEGER
{
stopBits1Bit (1),
stopBits1dot5Bits (2),
stopBits2Bits (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the minimum number of stop bits in
the tx async frame"
::= { prtExClCnfgEntry 8}
prtExClRoutingProtocol OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
rip2 (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the routing protocol of the port.
When prtExClUsage is nmsSlip or nmsPpp - all values are
applicable .
Else - only 'none' is applicable."
::= { prtExClCnfgEntry 9}
prtExClEnabled OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates if Ethernet port of CL
is enabled or not for management.
It is applicable only on the ETH port of the CL, when the
MP includes an ML-IP card.
disabled - will happen when there is Inband Management via
the ML-IP link/s
enabled - will happen when ML-IP link/s is not used for Inband
Management, but CL's ETH port ."
::= { prtExClCnfgEntry 10}
--
-- MPH1.T1, MPH1.E1, MTML.1/T1 , MTML.1/E1, ML-20
-- TDM and Hybrid(TDM & Packet) Main Link Modules
--
--prtExPh1MlCnfgTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 1}
--prtExPh1MlTsTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 2}
--prtInPh1MlCnfgTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 3}
--prtInPh1MlDlciTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 4}
--prtPhMlCnfgTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 5}
--
-- T1/E1 Port Objects
--
prtExPh1MlCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExPh1MlCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"- For products supporting more than one configuration, the write operation
into the Table is valid only to the TmpCnfg entry.
- For products that do not support configurations, the write operation
into the Table will be to prtExPh1MlCnfgIdx=1."
::= {prtPh1MlCnfg 1}
prtExPh1MlCnfgEntry OBJECT-TYPE
SYNTAX PrtExPh1MlCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExPh1MlCnfgIdx, prtExPh1MlSltIdx, prtExPh1MlPrtIdx }
::= { prtExPh1MlCnfgTable 1}
PrtExPh1MlCnfgEntry ::=
SEQUENCE {
prtExPh1MlCnfgIdx Integer32,
prtExPh1MlSltIdx INTEGER,
prtExPh1MlPrtIdx INTEGER,
prtExPh1MlConnect INTEGER,
prtExPh1MlLineType INTEGER,
prtExPh1MlLineCode INTEGER,
prtExPh1MlLineLen INTEGER,
prtExPh1MlRestoreTime INTEGER,
prtExPh1MlTxGain INTEGER,
prtExPh1MlRxSensitivity INTEGER,
prtExPh1MlIdleCode Integer32,
prtExPh1MlTdmTrunk INTEGER,
prtExPh1MlClkMode INTEGER,
prtExPh1MlMfClkSrcSlt INTEGER,
prtExPh1MlMfClkSrcPrt INTEGER,
prtExPh1MlFdlType INTEGER,
prtExPh1MlInbandMng INTEGER,
prtExPh1MlInbandMngRate INTEGER,
prtExPh1MlRedundType INTEGER,
prtExPh1MlRedundSlot INTEGER,
prtExPh1MlRedundPort INTEGER,
prtExPh1MlRedundRecTime Integer32,
prtExPh1MlInbandMngRoutProt INTEGER,
prtExPh1MlIfType INTEGER,
prtExPh1MlMultiplier INTEGER,
prtExPh1MlSupportedTS Integer32,
prtExPh1MlImpedance INTEGER,
prtExPh1MlQ50BwControl INTEGER,
prtExPh1MlQ50SignalPair INTEGER,
prtExPh1MlInternalSwitch INTEGER,
prtExPh1MlSigService INTEGER,
prtExPh1MlFragmentSize Integer32
}
prtExPh1MlCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtExPh1MlCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExPh1MlSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid.
For the Vmux2100 Main Board notApplicable (1) is used."
::= { prtExPh1MlCnfgEntry 2}
prtExPh1MlPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
exPrt3 (3),
exPrt4 (4),
exPrt5 (5),
exPrt6 (6),
exPrt7 (7),
exPrt8 (8),
exPrt9 (9),
exPrt10 (10),
exPrt11 (11),
exPrt12 (12),
exPrt13 (13),
exPrt14 (14),
exPrt15 (15),
exPrt16 (16),
exPrt17 (17),
exPrt18 (18),
inPrt1 (101),
inPrt2 (102),
inPrt3 (103),
inPrt4 (104),
inPrt5 (105),
inPrt6 (106),
inPrt7 (107),
inPrt8 (108),
inPrt9 (109),
inPrt10 (110),
inPrt11 (111),
inPrt12 (112),
inPrt13 (113),
inPrt14 (114),
inPrt15 (115),
inPrt16 (116),
inPrt17 (117),
inPrt18 (118),
inPrt19 (119),
inPrt20 (120),
inPrt21 (121),
inPrt22 (122),
inPrt23 (123),
inPrt24 (124),
inPrt25 (125),
inPrt26 (126),
inPrt27 (127),
inPrt28 (128),
inPrt29 (129),
inPrt30 (130),
inPrt31 (131),
inPrt32 (132),
inPrt33 (133),
inPrt34 (134),
inPrt35 (135),
inPrt36 (136),
inPrt37 (137),
inPrt38 (138),
inPrt39 (139),
inPrt40 (140),
inPrt41 (141),
inPrt42 (142),
inPrt43 (143),
inPrt44 (144),
inPrt45 (145),
inPrt46 (146),
inPrt47 (147),
inPrt48 (148),
inPrt49 (149),
inPrt50 (150),
inPrt51 (151),
inPrt52 (152),
inPrt53 (153),
inPrt54 (154),
inPrt55 (155),
inPrt56 (156),
inPrt57 (157),
inPrt58 (158),
inPrt59 (159),
inPrt60 (160),
inPrt61 (161),
inPrt62 (162),
inPrt63 (163),
inPrt64 (164),
inPrt65 (165),
inPrt66 (166),
inPrt67 (167),
inPrt68 (168),
inPrt69 (169),
inPrt70 (170),
inPrt71 (171),
inPrt72 (172),
inPrt73 (173),
inPrt74 (174),
inPrt75 (175),
inPrt76 (176),
inPrt77 (177),
inPrt78 (178),
inPrt79 (179),
inPrt80 (180),
inPrt81 (181),
inPrt82 (182),
inPrt83 (183),
inPrt84 (184)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
MP-2100/2200:
MTML-1/E1 and MTML-1/T1 cards have only one external interface.
inPrt1, inPrt2 - for MTML-H/2E1 and HSH cards.
inPrt1..inPrt4 - for MTML-E2 and MSL-4 cards.
exPrt2..exPrt4 - for MTML-4 cards and others
exPrt1..exPrt8 - for ML-8 cards.
inPrt1..inPrt8 - for MSL-8 and VF-30 card family.
MP-104/204: only exPrt3 (3) is applicable.
MP-4100: intPrt1...intPrt84 - for CLX cards.
For other products' index see their specification."
::= { prtExPh1MlCnfgEntry 3}
prtExPh1MlConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered
in any of the mux algorithms. It also affects all the card
considerations because it may indicate that the module has only
one physical interface."
::= {prtExPh1MlCnfgEntry 4}
prtExPh1MlLineType OBJECT-TYPE
SYNTAX INTEGER
{
esfT1 (2), --> dsx1ESF
sfT1 (3), --> dsx1D4
g732nE1 (4), --> dsx1E1
g732nE1CRC (5), --> dsx1E1-CRC
g732sE1 (6), --> dsx1E1-MF
g732sE1CRC (7), --> dsx1E1-MF-CRC
g732unframed (8), --> dsx1Unframed, for T1 Unframed
e1Unframed (9), --> dsx1E1Unframed
framed (101)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the line type parameter for T1/E1 interface.
The user should select only the values which are relevant
to the specific port:
(2),(3), (8) - for T1 port
(4)..(7), (9) - for E1 port.
(101) framed - This value does not exist in standard MIB and is used
for a non-standard E1 port that doesn't has real framer.
Note: for old devices, g732unframed(8) was used as E1 Unframed.
That was because at the time this value did not exist in
the standard MIB (RFC-1406), so we added it in private MIB.
Now that it was added to standard MIB, private MIB was
updated as well.
This parameter has the same values as dsx1LineType in DS1
MIB (RFC-3895). The parameters in dsx1LineType are:
other (1)
esfT1 dsx1ESF (2)
sfT1 dsx1D4 (3)
g732nE1 dsx1E1 (4)
g732nE1CRC dsx1E1-CRC (5)
g732sE1 dsx1E1-MF (6)
g732sE1CRC dsx1E1-MF-CRC (7)
g732unframed dsx1Unframed (8) --from RFC-3895
e1Unframed dsx1E1Unframed (9) --from RFC-3895 "
::= { prtExPh1MlCnfgEntry 5}
prtExPh1MlLineCode OBJECT-TYPE
SYNTAX INTEGER
{
b7T1 (1), --> dsx1JBZS (for E1 & T1)
b8zsT1 (2), --> dsx1B8ZS (for E1 & T1)
transT1(3), --> dsx1AMI
hdb3E1 (4), --> dsx1HDB3 (for E1 & T1)
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the line code parameter used for T1/E1
interface.
The user should select only the parameters which are relevant
to the specific card:
T1 line code parameters for MPH.1/T1
E1 line code parameters for MPH.1/E1.
This parameter has the same values as dsx1LineCoding in T1/E1
MIB (RFC-1406). The parameters in dsx1LineCoding are:
dsx1JBZS (1)
dsx1B8ZS (2)
dsx1HDB3 (3)
dsx1ZBTSI (4)
dsx1AMI (5)
other (6)"
::= { prtExPh1MlCnfgEntry 6}
prtExPh1MlLineLen OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
len0p133ft (2),
len134p266ft (3),
len267p399ft (4),
len400p533ft (5),
len534p655ft (6),
lenFcc68 (7),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the line length parameter used only for T1/DSU
interfaces.
lenXXXpXXXft = len-XXX-XXXft."
::= { prtExPh1MlCnfgEntry 7}
prtExPh1MlRestoreTime OBJECT-TYPE
SYNTAX INTEGER
{
restoreT1secFast (2),
restoreT10sec62411 (3),
ccittE1 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time passing from the disappearance of the loss of
synchronization condition (red alarm) to the restoration of
normal service. The options 1secFast(2) and 10sec62411(3)
for E1 interfaces are proprietary implementation of the T1
standard to the E1 interface."
::= { prtExPh1MlCnfgEntry 8}
prtExPh1MlTxGain OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
txGain0db (2),
txGain7dot5db (3),
txGain15db (4),
txGain22dot5db (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the tx gain parameter used only for
T1/CSU interfaces."
::= { prtExPh1MlCnfgEntry 9}
prtExPh1MlRxSensitivity OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
low26dBm (2),
high36dBm (3),
shortHaul (4),
longHaul (5),
low15dbm (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the rx line sensitivity parameter.
low26dBm, high36dBm - applicable for T1-CSU
shortHaul, longHaul - applicable for MTML-4 cards
low15dbm was added for vmux110/210 T1 ports."
::= { prtExPh1MlCnfgEntry 10}
prtExPh1MlIdleCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines the code for transmission in empty time slots.
Type value(00-FFH), Excluding 0H,8H,10H,12H,21H,24H,42H,49H,
84H,92H"
::= { prtExPh1MlCnfgEntry 11}
prtExPh1MlTdmTrunk OBJECT-TYPE
SYNTAX INTEGER
{
linkA (1),
linkB (2),
none (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port is used to transfer
TDM cards data and through which Bus."
::= {prtExPh1MlCnfgEntry 12}
prtExPh1MlClkMode OBJECT-TYPE
SYNTAX INTEGER
{
internalLocal (1),
loopBackLocal (2),
nodalTiming (3),
loopBackFromLink (4),
loopBackFromChannel (5),
loopbackFromSystem (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the clock operation mode of the T1/E1 interface.
Ports that are connected to the TDM Buses must be in
nodalTiming(3) clock mode. "
::= {prtExPh1MlCnfgEntry 13}
prtExPh1MlMfClkSrcSlt OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
local (2),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port Tx multiframe is
synchronized with Rx multiframe of another port and the slot
position of that port.
This operation is required in order to bypass signaling of
PCM voice channels. Its value is always local(2) when the port
isn't connected to any TDM bus. When it's value is local(2)
there is no meaning to 'prtExPh1MlMfClkSrcPrt' parameter.
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= {prtExPh1MlCnfgEntry 14}
prtExPh1MlMfClkSrcPrt OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
inPrt1 (101),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique number to identify a port position in the mux. It
has no effect when the prtExPh1MlMfClkSrcSlt selected is Local.
inPrt1 - for MTML-H/E1 cards."
::= {prtExPh1MlCnfgEntry 15}
prtExPh1MlFdlType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
response (2),
command (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique number to identify the side of the FDL operation.
Normal: 'response' for the user side and 'command' for the PTT
side.
Applicable only when working with ESF-T1 link"
::= {prtExPh1MlCnfgEntry 16}
prtExPh1MlInbandMng OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
fdlOrTs0 (3),
dedicatedTs (4),
dedicatedPpp (5),
dedicatedFr (6),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique number to identify an Inband management over the
link."
::= {prtExPh1MlCnfgEntry 17}
prtExPh1MlInbandMngRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
r4k (2),
r8k (3),
r12k (4),
r16k (5),
r32k (6),
r64k (7),
r20k (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique number to identify the rate of the Inband
management (Kbps).
E1 port - it is not applicable when prtExPh1MlInbandMng
selected is off.
T1 port - it is not applicable when prtExPh1MlInbandMng
selected is off OR fdlOrTs0."
::= {prtExPh1MlCnfgEntry 18}
prtExPh1MlRedundType OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
dualCableAIS (2),
yCable (3),
dualCableParallelTx (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines the ML redundancy type:
none - no ML redundacy
dualCableAIS - each ML card is connected by a separate
dualCableParallelTx cable to the other MUX (two cables
connect two MUXes). There are two
types of dual redundancy.
yCable - Y cable is connected to both ML cards (one cable
connects two MUXes).
Default=none
When only one ML card exists, the type can be only 'none'.
The value should be the same for both ML slots."
::= {prtExPh1MlCnfgEntry 19}
prtExPh1MlRedundSlot OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the slot containing the redundacy ML
card, coupled with the current ML (prtExPh1MlSltIdx).
When prtExPh1MlRedundType=none (no ML redundancy) this
object will be 'notApplicable'.
In the ?004 Unit the entries io6(10)..io12(16) are not valid
When value is not 'none', it should be mutual to the
redundant ML slot."
::= {prtExPh1MlCnfgEntry 20}
prtExPh1MlRedundPort OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
exPrt3 (3),
exPrt4 (4),
inPrt1 (101),
inPrt2 (102),
inPrt3 (103),
inPrt4 (104),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the redundacy ML port, coupled with the
current ML port (prtExPh1MlPrtIdx).
When prtExPh1MlRedundType=none (no ML redundancy) this
object will be 'notApplicable'.
When value is not 'none', it should be mutual to the
redundant ML port.
inPrt1 - for MTML-H/E1 cards.
inPrt1..inPrt4 - for MTML-E2 cards.
exPrt2..exPrt4 - for MTML-4 cards."
::= {prtExPh1MlCnfgEntry 21}
prtExPh1MlRedundRecTime OBJECT-TYPE
SYNTAX Integer32 (1..99)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Redundancy Recovery Time (sec). After switching the ML card
to the current (prtExPh1MlSltIdx), the next ML switch can
be performed only after a minimum time, indicated by
this object."
::= {prtExPh1MlCnfgEntry 22}
prtExPh1MlInbandMngRoutProt OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
rip2 (2),
proprietary (3),
proprietaryNoNmsTx (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Inband Mng routing protocol of
the port."
::= {prtExPh1MlCnfgEntry 23}
prtExPh1MlIfType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
csu (2),
dsu (3),
ltu (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Interface type of the port.
For T1 - csu, dsu are the valid values
For E1 - dsu, ltu are the valid values."
::= {prtExPh1MlCnfgEntry 24}
prtExPh1MlMultiplier OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
br56 (2),
br64 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The data rate of each TS. The multiplier values
can be 56 kbps or 64 kbps."
::= {prtExPh1MlCnfgEntry 25}
prtExPh1MlSupportedTS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Supported Time Slots by the agent.
For Vmux-110 there is HW that supports less than 31/24
Time Slots for the E1/T1 port."
::= {prtExPh1MlCnfgEntry 26}
prtExPh1MlImpedance OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
unbalanced (2),
balanced (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Line Impedance.
For T1 (always balanced), impedance is 100 ohm.
For E1:
- balanced = 120 ohm
- unbalanced = 75 ohm."
::= {prtExPh1MlCnfgEntry 27}
prtExPh1MlQ50BwControl OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
annexA (3),
annexB (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables configuration of Q.50 Bandwidth Control on the port.
If the bandwidth exceeds a certain threshold it is possible to disable
new calls in the PBX via Q.50 protocol.
Q.50 supports only E1 ports with Line Types:
E1-MF (G.732S), E1-CRC-MF(G.732SCRC )
It does not support T1 ports.
Annex A - the basic type of Q.50 which focuses only on the bandwidth control.
Can use one of the following pairs of signaling bits: A&B or C&D.
Annex B - Expansion of Annex A which includes also call release messages
and Maintenance Messages. Uses A&B bits only."
::= {prtExPh1MlCnfgEntry 28}
prtExPh1MlQ50SignalPair OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
aAndB (2),
cAndD (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Q.50 Signaling bits Pair that is currently in use:
A&B bits or C&D bits. For Annex B it will always be: aAndB (2)."
::= {prtExPh1MlCnfgEntry 29}
prtExPh1MlInternalSwitch OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter shows whether the data will be transferred from one port to
the other port within the same group of 2 ports.
The default value is: Enable.
Disable value might be necessary for security implementations or
for ring applications.
For Vmux-2100 device this parameter is used on the Channelized Cards.
Both ports in each group should have the same value for this parameter."
::= {prtExPh1MlCnfgEntry 30}
prtExPh1MlSigService OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
normal (2),
advanced (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Signaling Service given by this link.
notApplicable - for T1 links
normal - usual Signaling
advanced - V5 Signaling. "
::= {prtExPh1MlCnfgEntry 31}
prtExPh1MlFragmentSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the maximum number of bytes permitted in a packet send over the Link.
Exceeding this size will cause packet fragmentation."
::= {prtExPh1MlCnfgEntry 32}
--
-- MPH1.T1 & MPH1.E1
-- Time Slot Assignment Table
--
prtExPh1MlTsTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExPh1MlTsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry, except prtExPh1MlTsTest that will be written
directly to the Active Configuration."
::= {prtPh1MlCnfg 2}
prtExPh1MlTsEntry OBJECT-TYPE
SYNTAX PrtExPh1MlTsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExPh1MlTsCnfgIdx, prtExPh1MlTsSltIdx, prtExPh1MlTsPrtIdx, prtExPh1MlTsIdx }
::= { prtExPh1MlTsTable 1}
PrtExPh1MlTsEntry ::=
SEQUENCE {
prtExPh1MlTsCnfgIdx Integer32,
prtExPh1MlTsSltIdx INTEGER,
prtExPh1MlTsPrtIdx INTEGER,
prtExPh1MlTsIdx Integer32,
prtExPh1MlTsIConSlot INTEGER,
prtExPh1MlTsIConPrt Integer32,
prtExPh1MlTsIConTs Integer32,
prtExPh1MlTsExt OBJECT IDENTIFIER,
prtExPh1MlTsTest INTEGER,
prtExPh1MlTsType INTEGER,
prtExPh1MlTsBundle Integer32,
prtExPh1MlTsTestDuration Integer32,
prtExPh1MlTsSubChType INTEGER,
prtExPh1MlTsSubChMask Integer32,
prtExPh1MlTsChRate INTEGER,
prtExPh1MlTsByteReversal INTEGER,
prtExPh1MlTsSigProfile INTEGER
}
prtExPh1MlTsCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtExPh1MlTsEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExPh1MlTsSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid.
For the Vmux2100 Main Board notApplicable (255) is used."
::= { prtExPh1MlTsEntry 2}
prtExPh1MlTsPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
exPrt3 (3),
exPrt4 (4),
exPrt5 (5),
exPrt6 (6),
exPrt7 (7),
exPrt8 (8),
exPrt9 (9),
exPrt10 (10),
exPrt11 (11),
exPrt12 (12),
exPrt13 (13),
exPrt14 (14),
exPrt15 (15),
exPrt16 (16),
exPrt17 (17),
exPrt18 (18),
inPrt1 (101),
inPrt2 (102),
inPrt3 (103),
inPrt4 (104),
inPrt5 (105),
inPrt6 (106),
inPrt7 (107),
inPrt8 (108),
inPrt9 (109),
inPrt10 (110),
inPrt11 (111),
inPrt12 (112),
inPrt13 (113),
inPrt14 (114),
inPrt15 (115),
inPrt16 (116),
inPrt17 (117),
inPrt18 (118),
inPrt19 (119),
inPrt20 (120) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
MPH.1/E1 and MPH.1/T1 cards have only one external interface.
exPrt2 - for ME1-2, MT1-2 and mhsPri cards.
exPrt3, exPrt4 - for mhsPri cards.
inPrt1 - for MTML-H/E1 cards."
::= { prtExPh1MlTsEntry 3}
prtExPh1MlTsIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique time slot position.
The valid time slots are 1..24 for T1 Card and
1..31 for E1 interface. In G732S-E1 lines time slot 16 is not
valid for data, it is dedicated for multiframe synchronization bits
and voice signaling."
::= { prtExPh1MlTsEntry 4}
prtExPh1MlTsIConSlot OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
noConnect (2),
split (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the specified time slot is
connected/routed internally in the Agent and to which card
it is connected.
In the ?004 Unit the entries io6(10)..io16) are not valid.
split - will be used when the Src TS is connected to more
than one slot OR more than one port (each needing
less than a whole TS)."
::= {prtExPh1MlTsEntry 5}
prtExPh1MlTsIConPrt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the internally (In Mux)
connected/routed port.
For MP, the values will be:
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
exPrt11 (11) ,
exPrt12 (12) ,
noConnect (100),
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103) ,
inPrt4 (104) ,
inPrt5 (105) ,
inPrt6 (106) ,
inPrt7 (107) ,
inPrt8 (108) ,
inPrt9 (109) ,
inPrt10 (110) ,
inPrt11 (111) ,
inPrt12 (112)
}
For other products see specific values at spec."
::= {prtExPh1MlTsEntry 6}
prtExPh1MlTsIConTs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique time slot position.
The valid time slots are 1..24 for T1 Card and
1..31 for E1 interface. In G732S-E1 lines time slot 16 is not
valid for data, it is dedicated to multiframe synchronization
and voice signaling."
::= {prtExPh1MlTsEntry 7}
prtExPh1MlTsExt OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A pointer to an extension of this table:
prtExTsSplitTable.
- If prtExPh1MlTsIConSlot='split', its value
should be set to the OBJECT IDENTIFIER of the
prtExTsSplitTable, with its relevant CnfgIdx,
SltIdx, PrtIdx, TsIdx and 1st TsBit.
- If prtExPh1MlTsIConSlot is not 'split', its value
should be set to the OBJECT IDENTIFIER { 0 0 }. "
::= { prtExPh1MlTsEntry 8 }
prtExPh1MlTsTest OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
localLoop (2),
remoteLoop (3),
remoteBert (8), -- BERT
localToneInjection (9),
remoteToneInjection (18),
localBert (30),
split (254),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a test to be activated on the selected TS.
It is applicable only when prtSTstCmd=testPerTS(31).
notApplicable - when prtSTstCmd is NOT testPerTS(31).
none - no test is applied for the selected TS.
split - when the tests are per Bit of the selected TS."
::= { prtExPh1MlTsEntry 9 }
prtExPh1MlTsType OBJECT-TYPE
SYNTAX INTEGER
{
noConnect (2),
data (3),
voice (4),
cas (5),
ss7 (6),
transparent (7),
data2 (8),
data3 (9),
data4 (10),
ss7n2 (11),
hdlcV2Compatible (12),
subCh1 (13),
subCh2 (14),
subCh3 (15),
subCh4 (16),
subCh5 (17),
subCh6 (18),
subCh7 (19),
subCh8 (20),
trau (21),
qmux (22),
dynamic (23),
signaling (24),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Time Slot Type.
Transparent - means that the Time Slot will be Rx/Tx as is without processing it.
If the device requires more than 1 unique data or ss7 Time Slot,
options with numbers can be used like: data...data4.
Each numbered Type can go to a different destination.
ss7n2 - means the 2nd group of ss7 Time Slots.
data2,data3, data4 mean group 2,3,4 of Data Time Slots.
subCh1...subCh8 mean Sub Channel 1...8, respectively.
trau, qmux, dynamic, signaling - are used by GSM devices."
::= { prtExPh1MlTsEntry 10 }
prtExPh1MlTsBundle OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of the bundle containing this Time Slot.
If no bundle exists for this TS or the bundle number
is irrelevant, the value will be 0."
::= { prtExPh1MlTsEntry 11 }
prtExPh1MlTsTestDuration OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the maximum duration of executing
a test on the specific TS. This entry applies to all the
test operations.
For the Vmux2100 the values are:
0 - 60 seconds.
A zero value specifies no time limitation.
When the test isn't active, the agent initiates this object to
2 when the duration is needed and to 0 if its not required.
The user should set this parameter after setting the
'prtExPh1MlTsTest' parameter."
::= { prtExPh1MlTsEntry 12 }
prtExPh1MlTsSubChType OBJECT-TYPE
SYNTAX INTEGER
{
hdlc (1),
transparent (2),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Time Slot Sub-Channel Type.
This variable is relevant only when Time-Slot Type is SubCh
(e.g. prtExPh1MlTsType = subCh1...subCh8)."
::= { prtExPh1MlTsEntry 13 }
prtExPh1MlTsSubChMask OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Sub-Channel Type Mask.
This variable is relevant only when Time-Slot Type is SubCh
(e.g. prtExPh1MlTsType = subCh1...subCh8)."
::= { prtExPh1MlTsEntry 14 }
prtExPh1MlTsChRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
r16Kbps (2),
r32Kbps (3),
r64Kbps (4),
r8Kbps (5),
auto (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Rate of the Signaling Channel.
notApplicable(1) when TS Type is other than Signaling or Transparent"
::= { prtExPh1MlTsEntry 15 }
prtExPh1MlTsByteReversal OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Byte Reversal.
This variable defines whether the LSB or MSB is transmitted first.
no(2) - MSB is transmitted first
yes(3) - LSB is transmitted first."
::= { prtExPh1MlTsEntry 16 }
prtExPh1MlTsSigProfile OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
-- none (2),
p1 (3),
p2 (4),
p3 (5),
p4 (6),
p5 (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Signaling Profile of the port.
It is applicable only when prtMl4SigProfile=perTS.
p1 = profile 1
p2 = profile 2
p3 = profile 3
p4 = profile 4
p5 = profile 5 "
::= { prtExPh1MlTsEntry 17 }
--
-- MPH.1/T1 & MPH.1/E1
-- Internal port objects table
-- (only for the Hybrid modules)
--
prtInPh1MlCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInPh1MlCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtPh1MlCnfg 3}
prtInPh1MlCnfgEntry OBJECT-TYPE
SYNTAX PrtInPh1MlCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtInPh1MlCnfgIdx, prtInPh1MlSltType, prtInPh1MlPrtIdx }
::= { prtInPh1MlCnfgTable 1}
PrtInPh1MlCnfgEntry ::=
SEQUENCE {
prtInPh1MlCnfgIdx Integer32,
prtInPh1MlSltType INTEGER,
prtInPh1MlPrtIdx Integer32,
prtInPh1MlConnect INTEGER,
prtInPh1MlRate INTEGER,
prtInPh1MlProtocol INTEGER,
prtInPh1MlConnectionTyp INTEGER,
prtInPh1MlCongResponse INTEGER,
prtInPh1MlCongLevel Integer32,
prtInPh1MlTc INTEGER,
prtInPh1MlFlowControl INTEGER,
prtInPh1MlSegment INTEGER,
prtInPh1MlFrMngProt INTEGER,
prtInPh1MlEnqPeriod Integer32,
prtInPh1MlFullRptPeriod Integer32,
prtInPh1MlFrWindowSize Integer32,
prtInPh1MlErrorsThreshold Integer32,
prtInPh1MlMaxIdleTime Integer32,
prtInPh1MlBearerCh INTEGER,
prtInPh1MlAssociatedExCh INTEGER,
prtInPh1MlClockEncoding INTEGER,
prtInPh1MlMinSeparators Integer32,
prtInPh1MlCcittCrc INTEGER,
prtInPh1MlFrameSeparator INTEGER
}
prtInPh1MlCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtInPh1MlCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtInPh1MlSltType OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
For ISDN BRI port of MX300/30:
io1(5) = isdn1(5) and io2(6) = isdn2(6)
In the ?004 Unit the entries io6(10)..io12(16) are not valid"
::= { prtInPh1MlCnfgEntry 2}
prtInPh1MlPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
MPH.1/E1 and MPH.1/T1 cards have three internal interfaces.
MX3000 modules may have up to 50 internal ports."
::= { prtInPh1MlCnfgEntry 3}
prtInPh1MlConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithms."
::= { prtInPh1MlCnfgEntry 4}
prtInPh1MlRate OBJECT-TYPE
SYNTAX INTEGER
{
r1x56eq56Kbps (1),
r1x64eq64Kbps (2),
r2x56eq112Kbps (3),
r2x64eq128Kbps (4),
r3x56eq168Kbps (5),
r3x64eq192Kbps (6),
r4x56eq224Kbps (7),
r4x64eq256Kbps (8),
r5x56eq280Kbps (9),
r5x64eq320Kbps (10),
r6x56eq336Kbps (11),
r6x64eq384Kbps (12),
r7x56eq392Kbps (13),
r7x64eq448Kbps (14),
r8x56eq448Kbps (15),
r8x64eq512Kbps (16),
r9x56eq504Kbps (17),
r9x64eq576Kbps (18),
r10x56eq560Kbps (19),
r10x64eq640Kbps (20),
r11x56eq616Kbps (21),
r11x64eq704Kbps (22),
r12x56eq672Kbps (23),
r12x64eq768Kbps (24),
r13x56eq728Kbps (25),
r13x64eq832Kbps (26),
r14x56eq784Kbps (27),
r14x64eq896Kbps (28),
r15x56eq840Kbps (29),
r15x64eq960Kbps (30),
r16x56eq896Kbps (31),
r16x64eq1024Kbps(32),
r17x56eq952Kbps (33),
r17x64eq1088Kbps(34),
r18x56eq1008Kbps(35),
r18x64eq1152Kbps(36),
r19x56eq1064Kbps(37),
r19x64eq1216Kbps(38),
r20x56eq1120Kbps(39),
r20x64eq1280Kbps(40),
r21x56eq1176Kbps(41),
r21x64eq1344Kbps(42),
r22x56eq1232Kbps(43),
r22x64eq1408Kbps(44),
r23x56eq1288Kbps(45),
r23x64eq1472Kbps(46),
r24x56eq1344Kbps(47),
r24x64eq1536Kbps(48),
r25x56eq1400Kbps(49),
r25x64eq1600Kbps(50),
r26x56eq1456Kbps(51),
r26x64eq1664Kbps(52),
r27x56eq1512Kbps(53),
r27x64eq1728Kbps(54),
r28x56eq1568Kbps(55),
r28x64eq1792Kbps(56),
r29x56eq1624Kbps(57),
r29x64eq1856Kbps(58),
r30x56eq1680Kbps(59),
r30x64eq1920Kbps(60),
r31x56eq1736Kbps(61),
r31x64eq1984Kbps(62),
r32x56eq1792Kbps(63),
r32x64eq2048Kbps(64),
r1x1dot5eq1dot5M(65),
r2x1dot5eq3M (66),
r3x1dot5eq4dot5M(67),
r4x1dot5eq6M (68),
r5x1dot5eq7dot5M(69),
r6x1dot5eq9M (70),
r7x1dot5eq10dot5M(71),
r8x1dot5eq12M (72),
r1x2Meq2M (73),
r2x2Meq4M (74),
r3x2Meq6M (75),
r4x2Meq8M (76),
r5x2Meq10M (77),
r6x2Meq12M (78),
r7x2Meq14M (79),
r8x2Meq16M (80),
noRate (100)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the port speed. "
::= { prtInPh1MlCnfgEntry 5}
prtInPh1MlProtocol OBJECT-TYPE
SYNTAX INTEGER
{
fr (1),
frPlus (2),
pCellRelay (3),
hdlcSdlc (4),
transparentHdlc (5),
ciscoBridgedEth (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the applied protocol."
::= { prtInPh1MlCnfgEntry 6}
prtInPh1MlConnectionTyp OBJECT-TYPE
SYNTAX INTEGER
{
sameNetManaged (1),
sameNetNotMana (2),
user (3),
otherNet (4),
pubNet (5),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the link connection type.
It is required for three reasons:
FR/CR Inband management operation (LMI,CLMM...).
CIR check.
NMS network management.
SameNetManaged - indicates network internal line.
SameNetNotMana - indicates network internal line, but the remote
mux is not managed by the nms.
User - User to Network Interface.
OtherNet - Network To Network Interfce.
PubNet - Access Mux To PubNet Interface."
::= { prtInPh1MlCnfgEntry 7}
prtInPh1MlCongResponse OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
flowControl (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates how to handle the congestion indication
to/from the mux internal connection side (for example
transmit/receive becn to/from the network).
no - do nothing
FlowControl - translate the congestion indication between the
port and the internal connection port according to
the definition of the prtInPh1MlFlowControl
parameters. The operation is done in both directions."
::= { prtInPh1MlCnfgEntry 8}
prtInPh1MlCongLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the level of delayed data in
precents of the total available dynamic memory,
for which the port will start to operate .
The resolution of the parameter is 5 percent.
Valid values: 10..70, 255.
255=notApplicable."
::= { prtInPh1MlCnfgEntry 9}
prtInPh1MlTc OBJECT-TYPE
SYNTAX INTEGER
{
tc1sec (1),
tc2sec (2),
tc3sec (3),
tc4sec (4),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Tc parameter which is the time
period of the sliding window in which the Bc/Be are tested.
The value of this parameter is identical for all the ports in the
specific card.
255=notApplicable."
::= { prtInPh1MlCnfgEntry 10}
prtInPh1MlFlowControl OBJECT-TYPE
SYNTAX INTEGER
{
none (2),
fecnBecn (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the required flow control betweeen
the port and the remote equipment."
::= { prtInPh1MlCnfgEntry 11}
prtInPh1MlSegment OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
s36Byte (2),
s150Byte (3),
s264Byte (4),
s378Byte (5),
s492Byte (6),
s236Byte (7),
s472Byte (8),
s708Byte (9),
s944Byte (10),
s1180Byte (11)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Segmentation in Bytes.
In protocol FR+, ISDN internals, MX 30/300 the segmentation is:
50 (2) ,158 (3) ,266 (4) ,376 (5), 484 (6)
In MX 3000/4:
For protocol FR+ (internal ISDN ports of MHS.S, MHS.U, MHS.E1, MHS.T1
cards) segmentation values are:
236 (7),472 (8), 708 (9), 944 (10) ,1180 (11)"
::= { prtInPh1MlCnfgEntry 12}
prtInPh1MlFrMngProt OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
lmi (3),
ansiT1 (4), --Annex D
annexA (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Frame-Relay management protocol.
ansiT1 = ANSI T1.617 Annex D (this is the default value).
This parameter is applicable only for FR and FR+ protocols.
When prtInPh1MlConnectionTyp = sameNetManaged, this object
will be RO (internally determined). "
::= { prtInPh1MlCnfgEntry 13}
prtInPh1MlEnqPeriod OBJECT-TYPE
SYNTAX Integer32 (0..30)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Status Enquiry Period, in seconds.
It determines the frequency of the Status Enquiry message
as sent by the FR user side.
At the FR network side, it determines the timeout for this
message reception.
Default = 4 seconds.
This parameter is applicable only for FR and FR+ protocols
AND
only when prtInPh1MlFrMngProt is NOT (notApplicable or none).
0=notApplicable."
::= { prtInPh1MlCnfgEntry 14}
prtInPh1MlFullRptPeriod OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Full Report Frequency.
It determines the number of the Status Enquiry messages
sent by the FR user side, before a Full Report Request is
sent.
The units are : Status Enquiry messages (periods).
Valid values: 1 .. 255.
255 = infinite (never sent).
This parameter is applicable only for FR and FR+ protocols
AND
only when prtInPh1MlFrMngProt is NOT (notApplicable or none).
0=notApplicable."
::= { prtInPh1MlCnfgEntry 15}
prtInPh1MlFrWindowSize OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the FR Window Size.
It determines the number of samplings in the sliding window
that counts the errors.
This parameter is applicable only for FR and FR+ protocols
AND
only when prtInPh1MlFrMngProt is NOT (notApplicable or none).
0=notApplicable."
::= { prtInPh1MlCnfgEntry 16}
prtInPh1MlErrorsThreshold OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Max Errors.
It determines the number of Status Enquiry Errors that
occured within the FR sliding window, before this port is
considered DOWN (threshold).
This parameter is applicable only for FR and FR+ protocols
AND
only when prtInPh1MlFrMngProt is NOT (notApplicable or none).
0=notApplicable. "
::= { prtInPh1MlCnfgEntry 17}
prtInPh1MlMaxIdleTime OBJECT-TYPE
SYNTAX Integer32 (0..1800)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Move to higher prioritized connected link after this period of
seconds of silence on the current link.
0=Never. Never move to higher prioritized connected link.
UNIT is seconds.
Valid values are: 0, 1, 2, 3, 4, 5, 10, 20, 30, 40, 50, 60, 120, 180, 240, 300,
360, 420, 480, 540, 600, 900, 1200, 1500, 1800.
Attempt to Set an invalid value will result in getting the default value."
DEFVAL { 10 }
::= {prtInPh1MlCnfgEntry 18}
prtInPh1MlBearerCh OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
channelB1 (3),
channelB2 (4),
chB1andchB2 (5),
none (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines which B (bearer) channels are used for transferring ISDN data.
Default value is: none (255).
anyChannel (2) is skipped because it is not in use here."
::= {prtInPh1MlCnfgEntry 19}
prtInPh1MlAssociatedExCh OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
exPrt3 (3),
exPrt4 (4),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the external port associated to this internal
port. At present, it is used by the Hybrid (mp2100h), MHS-4 cards which
can have up to 64 dynamic internal ports associated with External ports.
For ISDN cards, the value will be: notApplicable (255).
The associated external of an ISDN internal port is represented
by the MIB object: prtIsdnDirectoryPrtNu."
::= { prtInPh1MlCnfgEntry 20}
prtInPh1MlClockEncoding OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
nrz (2),
nrzI (3),
fm0 (4),
manchester (5),
diffManchester(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Encoding type of the Line.
This parameter is applicable only for FR and FR+ protocols."
::= { prtInPh1MlCnfgEntry 21}
prtInPh1MlMinSeparators OBJECT-TYPE
SYNTAX Integer32 (0..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minimum number of bytes separating between two adjacent frames (HDLC item).
0 = notApplicable"
::= { prtInPh1MlCnfgEntry 22}
prtInPh1MlCcittCrc OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
crc16 (2),
crc32 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates how many Bits are used for CRC (HDLC item)."
::= { prtInPh1MlCnfgEntry 23}
prtInPh1MlFrameSeparator OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
idles (2),
flags (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates what should be transferred on the line when there
are no frames to pass (HDLC item).
idles: mean that FF will pass on the line
flags: mean that 7E will pass on the line."
::= { prtInPh1MlCnfgEntry 24}
--
-- MPH1.T1 & MPH1.E1
-- Internal port Dlci objects table
--
prtInPh1MlDlciTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInPh1MlDlciEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtPh1MlCnfg 4}
prtInPh1MlDlciEntry OBJECT-TYPE
SYNTAX PrtInPh1MlDlciEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtInPh1MlDlciCnfgIdx, prtInPh1MlDlciSltIdx, prtInPh1MlDlciPrtIdx, prtInPh1MlDlciIdx }
::= { prtInPh1MlDlciTable 1}
PrtInPh1MlDlciEntry ::=
SEQUENCE {
prtInPh1MlDlciCnfgIdx Integer32,
prtInPh1MlDlciSltIdx INTEGER,
prtInPh1MlDlciPrtIdx INTEGER,
prtInPh1MlDlciIdx Integer32,
prtInPh1MlDlciValid INTEGER,
prtInPh1MlDlciIConSlt INTEGER,
prtInPh1MlDlciIConPrt INTEGER,
prtInPh1MlDlciIConDlci Integer32,
prtInPh1MlDlciTxBc INTEGER,
prtInPh1MlDlciTxBe INTEGER,
prtInPh1MlDlciRxBc INTEGER,
prtInPh1MlDlciRxBe INTEGER,
prtInPh1MlDlciPriority Integer32,
prtInPh1MlDlciStatus INTEGER
}
prtInPh1MlDlciCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtInPh1MlDlciEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtInPh1MlDlciSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= { prtInPh1MlDlciEntry 2}
prtInPh1MlDlciPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique internal port number.
MPH.1/E1 and MPH.1/T1 cards have three internal ports."
::= { prtInPh1MlDlciEntry 3}
prtInPh1MlDlciIdx OBJECT-TYPE
SYNTAX Integer32 (1..991)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique index for each possible
used dlci(16..991). When the protocol is not Multiplexing
protocol, then its type is 'user' and the only valid index
is 1."
::= { prtInPh1MlDlciEntry 4}
prtInPh1MlDlciValid OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the attributes in this entry
are valid or not. The user can add/delete pvc (dlci to dlci
connection) by modifing this object"
::= { prtInPh1MlDlciEntry 5}
prtInPh1MlDlciIConSlt OBJECT-TYPE
SYNTAX INTEGER
{
noConnect(2),
cl (3),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position In the Mux
(Agent) where the dlci is routed to.
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= { prtInPh1MlDlciEntry 6}
prtInPh1MlDlciIConPrt OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
clNMS (99) ,
noConnect (100),
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103) ,
inPrt4 (104) ,
inPrt5 (105) ,
inPrt6 (106) ,
inPrt7 (107) ,
inPrt8 (108) ,
inPrt9 (109) ,
inPrt10 (110) ,
inPrt11 (111) ,
inPrt12 (112)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique port id which the dlci is
routed to."
::= { prtInPh1MlDlciEntry 7}
prtInPh1MlDlciIConDlci OBJECT-TYPE
SYNTAX Integer32 (1..991)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique internal connection dlci
number which the src dlci is routed to."
::= { prtInPh1MlDlciEntry 8}
prtInPh1MlDlciTxBc OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
txBc9600bps (3),
txBc14200bps (4),
txBc19200bps (5),
txBc28800bps (6),
txBc32000bps (7),
txBc38400bps (8),
txBc48000bps (9),
txBc56000bps (10),
txBc57600bps (11),
txBc64Kbps (12),
txBc128Kbps (13),
txBc192Kbps (14),
txBc256Kbps (15),
txBc320Kbps (16),
txBc384Kbps (17),
txBc448Kbps (18),
txBc512Kbps (19),
txBc768Kbps (20),
txBc1024Kbps (21)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Tx committed bandwidth on
the user transmit line or at the port receive line."
::= { prtInPh1MlDlciEntry 9}
prtInPh1MlDlciTxBe OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
txBe9600bps (3),
txBe14200bps (4),
txBe19200bps (5),
txBe28800bps (6),
txBe32000bps (7),
txBe38400bps (8),
txBe48000bps (9),
txBe56000bps (10),
txBe57600bps (11),
txBe64Kbps (12),
txBe128Kbps (13),
txBe192Kbps (14),
txBe256Kbps (15),
txBe320Kbps (16),
txBe384Kbps (17),
txBe448Kbps (18),
txBe512Kbps (19),
txBe768Kbps (20),
txBe1024Kbps (21)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Tx excess bandwidth on the
user transmit line or at the port receive line."
::= { prtInPh1MlDlciEntry 10}
prtInPh1MlDlciRxBc OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
rxBc9600bps (3),
rxBc14200bps (4),
rxBc19200bps (5),
rxBc28800bps (6),
rxBc32000bps (7),
rxBc38400bps (8),
rxBc48000bps (9),
rxBc56000bps (10),
rxBc57600bps (11),
rxBc64Kbps (12),
rxBc128Kbps (13),
rxBc192Kbps (14),
rxBc256Kbps (15),
rxBc320Kbps (16),
rxBc384Kbps (17),
rxBc448Kbps (18),
rxBc512Kbps (19),
rxBc768Kbps (20),
rxBc1024Kbps (21)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Rx committed bandwidth on
the user receive line or at the port transmit line."
::= { prtInPh1MlDlciEntry 11}
prtInPh1MlDlciRxBe OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
rxBe9600bps (3),
rxBe14200bps (4),
rxBe19200bps (5),
rxBe28800bps (6),
rxBe32000bps (7),
rxBe38400bps (8),
rxBe48000bps (9),
rxBe56000bps (10),
rxBe57600bps (11),
rxBe64Kbps (12),
rxBe128Kbps (13),
rxBe192Kbps (14),
rxBe256Kbps (15),
rxBe320Kbps (16),
rxBe384Kbps (17),
rxBe448Kbps (18),
rxBe512Kbps (19),
rxBe768Kbps (20),
rxBe1024Kbps (21)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Rx excess bandwidth on the
user receive line or at the port transmit line."
::= { prtInPh1MlDlciEntry 12}
prtInPh1MlDlciPriority OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique priority of the pcv.
1 is the lowest priority and 8 is the highest priority."
::= { prtInPh1MlDlciEntry 13}
prtInPh1MlDlciStatus OBJECT-TYPE
SYNTAX INTEGER
{
disconnected (1),
connected (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of the pvc. The status is
disconnected(1) when one of the sides is programmed as
not connected"
::= { prtInPh1MlDlciEntry 14}
--
-- ML-20 - High Speed Main Link card
-- External Port Objects
--
prtPhMlCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtPhMlCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtPh1MlCnfg 5}
prtPhMlCnfgEntry OBJECT-TYPE
SYNTAX PrtPhMlCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtPhMlCnfgIdx, prtPhMlSltIdx, prtPhMlPrtIdx }
::= { prtPhMlCnfgTable 1}
PrtPhMlCnfgEntry ::=
SEQUENCE {
prtPhMlCnfgIdx Integer32,
prtPhMlSltIdx INTEGER,
prtPhMlPrtIdx INTEGER,
prtPhMlConnect INTEGER,
prtPhMlRate INTEGER,
prtPhMlCAS INTEGER,
prtPhMlClockMode INTEGER,
prtPhMlSatBuffer INTEGER,
prtPhMlDialProcess INTEGER,
prtPhMlSyncRestore Integer32,
prtPhMlBus INTEGER,
prtPhMlMfSyncSlot INTEGER,
prtPhMlClockSource INTEGER,
prtPhMlErrCorrection INTEGER,
prtPhMlCorrectionMode INTEGER,
prtPhMlControlSignals INTEGER,
prtPhMlInterfaceType INTEGER,
prtPhMlClockPolarity INTEGER
}
prtPhMlCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtPhMlCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtPhMlSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
For the Vmux2100 Main Board notApplicable (1) is used."
::= { prtPhMlCnfgEntry 2}
prtPhMlPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
ML-20 cards have just one external interface."
::= { prtPhMlCnfgEntry 3}
prtPhMlConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered
in any of the mux algorithms."
::= {prtPhMlCnfgEntry 4}
prtPhMlRate OBJECT-TYPE
SYNTAX INTEGER
{
r1x64eq64Kbps (2),
r2x64eq128Kbps (4),
r3x64eq192Kbps (6),
r4x64eq256Kbps (8),
r5x64eq320Kbps (10),
r6x64eq384Kbps (12),
r7x64eq448Kbps (14),
r8x64eq512Kbps (16),
r9x64eq576Kbps (18),
r10x64eq640Kbps (20),
r11x64eq704Kbps (22),
r12x64eq768Kbps (24),
r13x64eq832Kbps (26),
r14x64eq896Kbps (28),
r15x64eq960Kbps (30),
r16x64eq1024Kbps(32),
r17x64eq1088Kbps(34),
r18x64eq1152Kbps(36),
r19x64eq1216Kbps(38),
r20x64eq1280Kbps(40),
r21x64eq1344Kbps(42),
r22x64eq1408Kbps(44),
r23x64eq1472Kbps(46),
r24x64eq1536Kbps(48),
r25x64eq1600Kbps(50),
r26x64eq1664Kbps(52),
r27x64eq1728Kbps(54),
r28x64eq1792Kbps(56),
r29x64eq1856Kbps(58),
r30x64eq1920Kbps(60),
r31x64eq1984Kbps(62),
r32x64eq2048Kbps(64),
auto (70)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the configured port speed.
auto - rate is adapted automatically to the attached modem rate."
::= {prtPhMlCnfgEntry 5}
prtPhMlCAS OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether Channel Associated
Signaling (CAS) is used."
::= {prtPhMlCnfgEntry 6}
prtPhMlClockMode OBJECT-TYPE
SYNTAX INTEGER
{
dce (2),
ext-dce (3),
dte (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock mode."
::= { prtPhMlCnfgEntry 7}
prtPhMlSatBuffer OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Satellite Buffer (+/- 256)."
::= {prtPhMlCnfgEntry 8}
prtPhMlDialProcess OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
callIn (3),
callOut (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Dial Process."
::= {prtPhMlCnfgEntry 9}
prtPhMlSyncRestore OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sync Restoration time, in seconds.
notApplicable=0. "
::= {prtPhMlCnfgEntry 10}
prtPhMlBus OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
busA (2),
busB (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TDM BUS this port is linked to."
::= {prtPhMlCnfgEntry 11}
prtPhMlMfSyncSlot OBJECT-TYPE
SYNTAX INTEGER
{
none (2),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the sync is synchronized
according to a certain card and the slot of this card.
This operation is required in order to bypass signaling of
PCM voice channels.
In the ?004 Unit the entries io6(10)..io12(16) are not valid"
::= {prtPhMlCnfgEntry 12}
prtPhMlClockSource OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
txClock (2),
rxClock (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Clock Source: TC (Tx Clock) or RC (Rx Clock) signals."
::= {prtPhMlCnfgEntry 13}
prtPhMlErrCorrection OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if Error Correction mechanism should be applied or not.
It will be applicable only if the interface HW includes the Error Correction
chip."
::= {prtPhMlCnfgEntry 14}
prtPhMlCorrectionMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
random (2),
bursty (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only when prtPhMlErrCorrection=yes.
random - enables to correct up to 3 random errors in an 23 bit frame
built from 12 data bits and 11 appended parity bits.
bursty - interleaving 3 frames, allows correcting bursts of 9 bit length."
::= {prtPhMlCnfgEntry 15}
prtPhMlControlSignals OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
ignore (2),
implement (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object shows whether the Port will ignore or implement the control signals
like DCD, CTS, DTR."
::= {prtPhMlCnfgEntry 16}
prtPhMlInterfaceType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
v35 (2),
x21 (3), -- v.11
rs232 (4), -- v.28
rs449 (5),
ei530 (6),
ei530a (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SW Configurable Interface Type."
::= {prtPhMlCnfgEntry 17}
prtPhMlClockPolarity OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
normal (2),
inverted (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the clock polarity."
::= {prtPhMlCnfgEntry 18}
-- This table is an extension for new version of MAXcess
-- modules.
prtLogicalCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtLogicalCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtLogicalCnfg 1}
prtLogicalCnfgEntry OBJECT-TYPE
SYNTAX PrtLogicalCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtLogicalCnfgIdx, prtLogicalSltIdx, prtLogicalPrtIdx }
::= { prtLogicalCnfgTable 1}
PrtLogicalCnfgEntry ::=
SEQUENCE {
prtLogicalCnfgIdx Integer32,
prtLogicalSltIdx INTEGER,
prtLogicalPrtIdx Integer32,
prtLogicalConnect INTEGER,
prtLogicalFunction INTEGER,
prtLogicalRowStatus RowStatus
}
prtLogicalCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtLogicalCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtLogicalSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot Index.
For ISDN BRI Ports of MX300/30,
io1(5) = isdn1(5) and io2(6) = isdn2(6)."
::= { prtLogicalCnfgEntry 2}
prtLogicalPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
This port number should be an internal port number:
inPrt1(101)->inPrt50(150), linkSel1(200)->linkSel50(250),
encaps1(300)-> encaps50(350), huntGr1(101) -> huntGr10(110)."
::= { prtLogicalCnfgEntry 3}
prtLogicalConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered
in any of the mux algorithms."
::= { prtLogicalCnfgEntry 4}
prtLogicalFunction OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
linkSelector(2),
encapsulator(3),
huntGroup(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter defines the function of the relevant channel."
::= { prtLogicalCnfgEntry 5 }
prtLogicalRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter allows the NMS to create/delete logical ports.
The only possible supported RowStatus vaules are
active (1) and destroy (6)."
::= { prtLogicalCnfgEntry 6 }
-- This group contains management information for the
-- link selector function.
linkSelectorCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkSelectorCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { prtLogicalCnfg 2}
linkSelectorCnfgEntry OBJECT-TYPE
SYNTAX LinkSelectorCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {linkSelectorCnfgIdx, linkSelectorSltIdx, linkSelectorPrtIdx }
::= { linkSelectorCnfgTable 1}
LinkSelectorCnfgEntry ::=
SEQUENCE {
linkSelectorCnfgIdx Integer32,
linkSelectorSltIdx INTEGER,
linkSelectorPrtIdx Integer32,
linkSelectorMaxIdleTime Integer32,
linkSelectorMode INTEGER,
linkSelectorRevert INTEGER,
linkSelectorMinBUSession Integer32
}
linkSelectorCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of
the Cnfg (1..100) being accessed.
Idx 255 relates to the TmpCnfg. "
::= { linkSelectorCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
linkSelectorSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot Index"
::= { linkSelectorCnfgEntry 2}
linkSelectorPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
This port number should be internal port number:
higher or equal to linkSeL1(201)."
::= { linkSelectorCnfgEntry 3}
linkSelectorMaxIdleTime OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Move to higher prioritized connected link
after this period of seconds of silence on the current link.
0=move immediately to higher prioritized connected link.
UNIT is seconds."
DEFVAL { 0 }
::= {linkSelectorCnfgEntry 4}
linkSelectorMode OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1),
backup(2), bod(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" If the link selector is in mode:
backup(2)=then the link with the lower priority will be
used in case of failure of the higher priority link,
bod(3)=bandwidth on demand or dynamic bandwidth allocation
means that links with lower priority will be used
whenever additional bandwidth is required. "
DEFVAL { backup }
::= {linkSelectorCnfgEntry 5}
linkSelectorRevert OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1),
auto(2), manual(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" If the link selector is in mode backup:
auto(2)=return automatically to Main link when it is OK.
manual(3)=stays connected to backup link."
DEFVAL { auto }
::= {linkSelectorCnfgEntry 6}
linkSelectorMinBUSession OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minimum duration of a backup session before
returning to Main Link. Relevant in Backup Mode and
when Revert is auto(2). Value 255 is for NEVER which
means never return to Main Link.
UNIT is minutes."
DEFVAL { 10 }
::= {linkSelectorCnfgEntry 7}
-- Prioritized Links
linkSelectorPLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkSelectorPLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { prtLogicalCnfg 3}
linkSelectorPLinkEntry OBJECT-TYPE
SYNTAX LinkSelectorPLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {pLinkCnfgIdx, pLinkSltIdx, pLinkPrtIdx, pLinkIdx }
::= { linkSelectorPLinkTable 1}
LinkSelectorPLinkEntry ::=
SEQUENCE {
pLinkCnfgIdx Integer32,
pLinkSltIdx INTEGER,
pLinkPrtIdx Integer32,
pLinkIdx Integer32,
pLinkSlotNu INTEGER,
pLinkPortNu Integer32,
pLinkPrioNu Integer32,
pLinkVRate INTEGER
}
pLinkCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { linkSelectorPLinkEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
pLinkSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot Index"
::= { linkSelectorPLinkEntry 2}
pLinkPrtIdx OBJECT-TYPE
SYNTAX Integer32(200..250)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
This port number should be the link selector number."
::= { linkSelectorPLinkEntry 3}
pLinkIdx OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This index is the row number."
::= { linkSelectorPLinkEntry 4}
pLinkSlotNu OBJECT-TYPE
SYNTAX INTEGER {
noConnect (2), cl(3),
io1(5),
io2(6),
io3(7),
io4(8),
io5(9),
io6(10),
io7(11),
io8(12),
io9(13),
io10(14),
io11(15),
io12(16),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The slot of the prioritized link.
For ISDN BRI ports of MX300/30,
io1(5) = isdn1(5) and io2(6) = isdn2(6)."
DEFVAL { noConnect }
::= { linkSelectorPLinkEntry 5 }
pLinkPortNu OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port of the prioritized link.
Value 100 is for noConnect."
DEFVAL { 100 }
::= { linkSelectorPLinkEntry 6 }
pLinkPrioNu OBJECT-TYPE
SYNTAX Integer32(1..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The priority of the prioritized link.
MIN=1...., MAX=8."
::= { linkSelectorPLinkEntry 7 }
pLinkVRate OBJECT-TYPE
SYNTAX INTEGER {
r1x56eq56Kbps (1),
r1x64eq64Kbps (2),
r2x56eq112Kbps (3),
r2x64eq128Kbps (4),
r3x56eq168Kbps (5),
r3x64eq192Kbps (6),
r4x56eq224Kbps (7),
r4x64eq256Kbps (8),
r5x56eq280Kbps (9),
r5x64eq320Kbps (10),
r6x56eq336Kbps (11),
r6x64eq384Kbps (12),
r7x56eq392Kbps (13),
r7x64eq448Kbps (14),
r8x56eq448Kbps (15),
r8x64eq512Kbps (16),
r9x56eq504Kbps (17),
r9x64eq576Kbps (18),
r10x56eq560Kbps (19),
r10x64eq640Kbps (20),
r11x56eq616Kbps (21),
r11x64eq704Kbps (22),
r12x56eq672Kbps (23),
r12x64eq768Kbps (24),
r13x56eq728Kbps (25),
r13x64eq832Kbps (26),
r14x56eq784Kbps (27),
r14x64eq896Kbps (28),
r15x56eq840Kbps (29),
r15x64eq960Kbps (30),
r16x56eq896Kbps (31),
r16x64eq1024Kbps(32),
r17x56eq952Kbps (33),
r17x64eq1088Kbps(34),
r18x56eq1008Kbps(35),
r18x64eq1152Kbps(36),
r19x56eq1064Kbps(37),
r19x64eq1216Kbps(38),
r20x56eq1120Kbps(39),
r20x64eq1280Kbps(40),
r21x56eq1176Kbps(41),
r21x64eq1344Kbps(42),
r22x56eq1232Kbps(43),
r22x64eq1408Kbps(44),
r23x56eq1288Kbps(45),
r23x64eq1472Kbps(46),
r24x56eq1344Kbps(47),
r24x64eq1536Kbps(48),
r25x56eq1400Kbps(49),
r25x64eq1600Kbps(50),
r26x56eq1456Kbps(51),
r26x64eq1664Kbps(52),
r27x56eq1512Kbps(53),
r27x64eq1728Kbps(54),
r28x56eq1568Kbps(55),
r28x64eq1792Kbps(56),
r29x56eq1624Kbps(57),
r29x64eq1856Kbps(58),
r30x56eq1680Kbps(59),
r30x64eq1920Kbps(60),
r31x56eq1736Kbps(61),
r31x64eq1984Kbps(62),
noRate(100)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The rate to use with this link."
DEFVAL { noRate }
::= { linkSelectorPLinkEntry 8 }
--
-- Megaplex or Kilomux ?000/?004 MPH.1/3 High speed packet data cards.
-- Megaplex or Kilomux ?000/?004 MPL.6 Low speed packet data cards.
-- (Mph1, Mph3, Mpl6)
-- Maxcess 3000/3004 MLS-3/6, MHS-1/3
--
-- prtExPhPlCnfgTable OBJECT IDENTIFIER ::= {prtPhPlCnfg 1}
-- prtExPhPlDlciTable OBJECT IDENTIFIER ::= {prtPhPlCnfg 2}
-- prtExPhPlModemTable OBJECT IDENTIFIER ::= {prtPhPlCnfg 3}
-- Mph.1 Mph.3 Mpl.6/ Kphs.1 Kphs.3 Mls.3 Mls.6 Mhs.1 Mhs.3
-- External port objects table
prtExPhPlCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExPhPlCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The write operation into the Table Objects is
valid only to the TmpCnfg entry."
::= {prtPhPlCnfg 1}
prtExPhPlCnfgEntry OBJECT-TYPE
SYNTAX PrtExPhPlCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExPhPlCnfgIdx, prtExPhPlSltIdx, prtExPhPlPrtIdx}
::= { prtExPhPlCnfgTable 1}
PrtExPhPlCnfgEntry ::=
SEQUENCE {
prtExPhPlCnfgIdx Integer32,
prtExPhPlSltIdx INTEGER,
prtExPhPlPrtIdx INTEGER,
prtExPhPlConnect INTEGER,
prtExPhPlHRate INTEGER,
prtExPhPlLRate INTEGER,
prtExPhPlProtocol INTEGER,
prtExPhPlConnectionTyp INTEGER,
prtExPhPlClkMode INTEGER,
prtExPhPlDceClkSrc INTEGER,
prtExPhPlCongResponse INTEGER,
prtExPhPlCongLevel Integer32,
prtExPhPlTc INTEGER,
prtExPhPlFlowControl INTEGER,
prtExPhPlDcdRts INTEGER,
prtExPhPlDcdRtsControlPath INTEGER,
prtExPhPlDataBits INTEGER,
prtExPhPlParity INTEGER,
prtExPhPlStopBits INTEGER,
prtExPhPlLXon Integer32,
prtExPhPlLXoff Integer32,
prtExPhPlFrMngProt INTEGER,
prtExPhPlEnqPeriod Integer32,
prtExPhPlFullRptPeriod Integer32,
prtExPhPlFrWindowSize Integer32,
prtExPhPlErrorsThreshold Integer32,
prtExPhPlPvcCreateMsg INTEGER,
prtExPhPlCllmMsg INTEGER,
prtExPhPlProtDelayLevel INTEGER,
prtExPhPlClockEncoding INTEGER,
prtExPhPlMinSeparators Integer32,
prtExPhPlCcittCrc INTEGER,
prtExPhPlFrameSeparator INTEGER,
prtExPhPlIdleCode Integer32,
prtExPhPlJitter Integer32
}
prtExPhPlCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtExPhPlCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExPhPlSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid"
::= { prtExPhPlCnfgEntry 2}
prtExPhPlPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
In case of PH.1 card, only exPrt(1) is valid."
::= { prtExPhPlCnfgEntry 3}
prtExPhPlConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered
in any of the mux algorithms."
::= { prtExPhPlCnfgEntry 4}
prtExPhPlHRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
r32KbpsNLE (2),
r48KbpsNLE (3),
r56KbpsNLE (4),
r64KbpsNLE (5),
r112KbpsNLE (6),
r128KbpsNLE (7),
r168KbpsNLE (8),
r192KbpsNLE (9),
r224KbpsNLE (10),
r256KbpsNLE (11),
r280KbpsE (12),
r320KbpsE (13),
r336KbpsNLE (14),
r384KbpsNLE (15),
r392KbpsE (16),
r448KbpsNLE (17),
r504KbpsLE (18), -- r504KbpsE
r512KbpsE (19), -- r512KbpsNLE
r560KbpsE (20),
r576KbpsLE (21), -- r576KbpsE
r616KbpsE (22),
r640KbpsE (23),
r672KbpsNLE (24),
r704KbpsE (25),
r728KbpsE (26),
r768KbpsNLE (27),
r784KbpsE (28),
r832KbpsE (29),
r840KbpsE (30),
r896KbpsNLE (31),
r952KbpsE (32),
r960KbpsE (33),
r1008KbpsLE (34), -- r1008KbpsE
r1024KbpsE (35), -- r1024KbpsNLE
r1064KbpsE (36),
r1088KbpsE (37),
r1120KbpsE (38),
r1152KbpsLE (39), -- r1152KbpsE
r1176KbpsE (40),
r1216KbpsE (41),
r1232KbpsE (42),
r1280KbpsE (43),
r1288KbpsE (44),
r1344KbpsNLE (45),
r1400KbpsE (46),
r1408KbpsE (47),
r1456KbpsE (48),
r1472KbpsE (49),
r1512KbpsE (50),
r1536KbpsE (51), -- r1536KbpsNLE
r1568KbpsE (52),
r1600KbpsE (53),
r1624KbpsE (54),
r1664KbpsE (55),
r1680KbpsE (56),
r1728KbpsE (57),
r1736KbpsE (58),
r1792KbpsNLE (59),
r1856KbpsE (60),
r1920KbpsE (61),
r1984KbpsE (62),
r2048KbpsE (63), -- r2048KbpsNLE
--
-- Additional rates for: MAXcess, MP2100h
--
r9d6KbpsNLE (65),
r14d4KbpsNLE (66),
r16KbpsNLE (67),
r19d2KbpsNLE (68),
r28d8KbpsNLE (69),
r38d4KbpsNLE (70),
r57d6KbpsNLE (71), -- For Mx 30/300 Only
r115d2KbpsNLE (72), -- For Mx 30/300 Only
r24000bps (73)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the port speed for HIGH speed cards.
The card has limitations about the maximum sigma channel
speeds and about the possible rates for each clock mode .
N - The rate is valid for DCE and EXT-DCE Nodal clock mode.
L - The rate is valid for DCE and EXT-DCE Local clock mode.
E - The rate is valid for DTE External clock mode.
'r9d6KbpsNLE' means rate of 9.6 Kbps ('d'=dot).
Note: Some rate attributes have been changed. As the MIB was already
released with the old attributes, the names of the options were
not changed. The new names + attributes are in a comment.
Example: r2048KbpsE (63), -- r2048KbpsNLE"
::= { prtExPhPlCnfgEntry 5}
prtExPhPlLRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
r300bpsNLE (2),
r600bpsNLE (3),
r800bpsNLE (4),
r1200bpsNLE (5),
r2400bpsNLE (6),
r4800bpsNLE (7),
r9600bpsNLE (8),
r14400bpsLE (9), -- r14400bpsNLE
r19200bpsNLE (10),
r28800bpsLE (11), -- r28800bpsNLE
r32000bpsNLE (12),
r38400bpsNLE (13),
r48000bpsNLE (14),
r56000bpsNLE (15),
r57600bpsLE (16), -- r57600bpsNLE
r64000bpsNLE (17),
r112000bps (18), -- For Mx 30/300 Only: r112000bpsNLE
r115200bps (19), -- For Mx 30/300 Only: r115200bpsNLE
--
-- additional rates
--
r16000bpsNLE (20),
r100bpsNLE (21), -- For Mx 30/300 Only
r128000bps (22), -- For Mx 30/300 Only
r24000bps (23)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the port speed for LOW speed cards.
The card has limitations about the possible rates for each
clock mode.
N - The rate is valid for DCE and EXT-DCE Nodal clock mode.
L - The rate is valid for DCE and EXT-DCE Local clock mode.
E - The rate is valid for DTE External clock mode.
Note: Some rate attributes have been changed. As the MIB was already
released with the old attributes, the names of the options were
not changed. The new names + attributes are in a comment.
Example: r57600bpsLE (16), -- r57600bpsNLE "
::= { prtExPhPlCnfgEntry 6}
prtExPhPlProtocol OBJECT-TYPE
SYNTAX INTEGER
{
fr (1),
frPlus (2),
pCellRelay (3),
hdlcSdlc (4),
transparentHdlc (5),
async (6),
asyncReliable (7),
activePPP (8),
slip (9),
pppAgent (10),
slipAgent (11),
transparent (12),
sna (13),
ft1Dot2 (14) -- Standard IEC 870-5-1 for Frame Transport
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the applied protocol."
::= { prtExPhPlCnfgEntry 7}
prtExPhPlConnectionTyp OBJECT-TYPE
SYNTAX INTEGER
{
sameNetManaged (1),
sameNetNotMana (2),
user (3),
otherNet (4),
pubNet (5),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the link connection type.
It is required for three reasons:
FR/CR Inband management opration (LMI,CLMM...).
CIR check.
NMS network management.
SameNetManaged - indicates network internal line.
SameNetMotMana - indicates network internal line, but the
remote mux is not managed by the NMS.
User - User to Network Interface.
OtherNet - Network To Network Interface.
PubNet - Access Mux To PubNet Interface."
::= { prtExPhPlCnfgEntry 8}
prtExPhPlClkMode OBJECT-TYPE
SYNTAX INTEGER
{
dce (1),
extDce (2),
dte (3),
int (4),
lbt (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock mode."
::= { prtExPhPlCnfgEntry 9}
prtExPhPlDceClkSrc OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
local (2),
nodalTiming (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the source of the clock when working
in dce or ext-dce clock mode.
notApplicable(1) - is applied for dte(3) and lbt(5) clock modes.
When clock mode is dte, the clock source is
always external, therefore this object's value is
notApplicable.
local(2) and nodalTiming(3) - are valid in dce(1), extDce(2)
or int(4) clock modes.
The recommended clock source is local(2)."
::= { prtExPhPlCnfgEntry 10}
prtExPhPlCongResponse OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
flowControl (3), -- duplex, to/from flow control
toFlowControl (4) -- simplex , only to flow control
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates how to handle the congestion indication
to/from the mux internal connection side (for example
transmit/received becn to/from the network).
no - do nothing
flowControl - translates the congestion indication between the
port and the internal connection port according
to the definition of the prtInPh1MlFlowControl
parameters. The operation is done on both
directions.
toFlowControl- translates the backward congestion indication
received from the internal connection port
(normally the network side) to flow control and
do nothing in the other direction."
::= { prtExPhPlCnfgEntry 11}
prtExPhPlCongLevel OBJECT-TYPE
SYNTAX Integer32 (0..70)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the level of delayed data in
precents of total available dynamic memory,
for which the port will start to operate as congested.
The resolution of the parameter is 5 percent."
::= { prtExPhPlCnfgEntry 12}
prtExPhPlTc OBJECT-TYPE
SYNTAX INTEGER
{
tc1sec (1),
tc2sec (2),
tc3sec (3),
tc4sec (4),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Tc parameter which is the time
period of the sliding window in which the Bc/Be are tested.
The value of this parameter is identical for all the ports
of a specific card ."
::= { prtExPhPlCnfgEntry 13}
prtExPhPlFlowControl OBJECT-TYPE
SYNTAX INTEGER
{
none (2),
fecnBecn (3),
xonXoff (4),
dtrCts (5),
speedReduction (6) -- simplex response only congestion to flow control
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the required flow control betweeen
the port and the remote equipment.
fecnBecn - is valid only for FR, FR+ and CR protocols.
xonXoff,dtrCts - are valid only for Async protocols.
speedReduction - is valid only for DLC protocol when the
Clock Mode is DCE and the Clock Source is
Local."
::= { prtExPhPlCnfgEntry 14}
prtExPhPlDcdRts OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
on (2),
endToEnd (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Protocol may require end to end connect indication over the
network. End to end link connection establishment over the
FR network will be indicated to the user by using DCD or
RTS control signals, depending on the clock mode: DCE or
DTE respectively.
The options are :
- On :
DCD(DCE)/RTS(DTE) will be constantly ON no matter
if the End to End connection is established or not.
- End to End:
The DCD(DCE)/RTS(DTE) will be according to the status
of the End to End connection."
::= { prtExPhPlCnfgEntry 15}
prtExPhPlDcdRtsControlPath OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Protocol may require end to end connect indication over the
network. This parameter defines whether to take the user
connection status (RTS(DCE)/DCD(DTE)) and forward it to the
network side.
- on : Transmit active connection to the network regardless
the RTS/DCD control lines status.
- off: Transmit active connection to the network according
to the status of the RTS/DCD pin. "
::= { prtExPhPlCnfgEntry 16}
prtExPhPlDataBits OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
dataBits7Bits (2),
dataBits8Bits (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the number of data bits in async
frame.
It is relevant only for Async protocols."
::= { prtExPhPlCnfgEntry 17}
prtExPhPlParity OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
odd (2),
even (3),
none (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the parity operation mode in
async frame.
It is relevant only for Async protocols."
::= { prtExPhPlCnfgEntry 18}
prtExPhPlStopBits OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
sb1Bit (2),
sb1dot5Bits (3),
sb2Bits (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the minimum number of stop bits
in the tx async frame.
It is relevant only for Async protocols."
::= { prtExPhPlCnfgEntry 19}
prtExPhPlLXon OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the character used as X-On to
notify receive enable.
This parameter is valid only for async protocols.
Valid values: 0..255.
The value 256 indicates that it's not applicable "
::= { prtExPhPlCnfgEntry 20}
prtExPhPlLXoff OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the character used as X-Off to
notify receive disable.
This parameter is valid only for async protocols.
Valid values: 0..255.
The value 256 indicates that it's not applicable "
::= { prtExPhPlCnfgEntry 21}
prtExPhPlFrMngProt OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
lmi (3),
ansiT1 (4), --Annex D
annexA (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Frame-Relay management protocol.
ansiT1 = ANSI T1.617 Annex D (this is the default value).
This parameter is applicable only for FR and FR+ protocols.
When prtExPhPlConnectionTyp = sameNetManaged, this object
will be RO (internally determined). "
::= { prtExPhPlCnfgEntry 22}
prtExPhPlEnqPeriod OBJECT-TYPE
SYNTAX Integer32 (1..30)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Status Enquiry Period, in seconds.
It determines the frequency of the Status Enquiry message
as sent by the FR user side.
At the FR network side, it determines the timeout for this
message reception.
Default = 4 seconds.
This parameter is applicable only for FR and FR+ protocols
AND
only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
::= { prtExPhPlCnfgEntry 23}
prtExPhPlFullRptPeriod OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Full Report Frequency.
It determines the number of the Status Enquiry messages
sent by the FR user side, before a Full Report Request is
sent.
The units are : Status Enquiry messages (periods).
Valid values: 1 .. 255.
255 = infinite.
This parameter is applicable only for FR and FR+ protocols
AND
only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
::= { prtExPhPlCnfgEntry 24}
prtExPhPlFrWindowSize OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the FR Window Size.
It determines the number of samplings in the sliding window
that counts the errors.
This parameter is applicable only for FR and FR+ protocols
AND
only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
::= { prtExPhPlCnfgEntry 25}
prtExPhPlErrorsThreshold OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Max Errors.
It determines the number of Status Enquiry Errors that
occured within the FR sliding window, before this port is
considered DOWN (threshold).
This parameter is applicable only for FR and FR+ protocols
AND
only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
::= { prtExPhPlCnfgEntry 26}
prtExPhPlPvcCreateMsg OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is Update Message (if required or not).
It determines whether a message of a New PVC Creation is
requested or not (yes/no).
Default = no.
This parameter is applicable only for FR and FR+ protocols
AND
only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
::= { prtExPhPlCnfgEntry 27}
prtExPhPlCllmMsg OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is CLLM Message (if required or not).
It determines whether to send (or not) a congestion message
when the port is Rx congested.
Default = no.
This parameter is applicable only for FR and FR+ protocols
AND
only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
::= { prtExPhPlCnfgEntry 28}
prtExPhPlProtDelayLevel OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
s36Byte (2), --level 1
s150Byte (3), --level 2
s264Byte (4), --level 3
s378Byte (5), --level 4
s492Byte (6) --level 5
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Segmentation in Bytes.
In some cases, the enumerated values will mean
other segmentation values than specified:
Product: MX-3000 MX-3000 MX-300/MX-30
Protocol: FR+ Transparent FR+
-----------------------------------------------------
level 1 50 Bytes 44 Bytes 50 Bytes
level 2 158 Bytes 155 Bytes 158 Bytes
level 3 266 Bytes 266 Bytes 266 Bytes
level 4 376 Bytes 377 Bytes 376 Bytes
level 5 484 Bytes 488 Bytes 484 Bytes
Defval=level 1 value
This parameter is applicable only for FR+ and
transparent protocols."
::= { prtExPhPlCnfgEntry 29}
prtExPhPlClockEncoding OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
nrz (2),
nrzI (3),
fm0 (4),
manchester (5),
diffManchester(6),
nrzISpace (7),
nrzIMark (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Encoding type of the Line.
This parameter is applicable only for FR and FR+ protocols.
For MAXCESS 3000 & MP2100H: when setting to nrzI (3) the nrzI works
as nrzI Mark.
For MAXCESS 30/300 when setting to nrzI (3) the nrzI works as nrzI Space."
::= { prtExPhPlCnfgEntry 30}
prtExPhPlMinSeparators OBJECT-TYPE
SYNTAX Integer32 (0..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minimum number of bytes separating between two adjacent frames (HDLC item).
0 = notApplicable"
::= { prtExPhPlCnfgEntry 31}
prtExPhPlCcittCrc OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
crc16 (2),
crc32 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates how many Bits are used for CRC (HDLC item)."
::= { prtExPhPlCnfgEntry 32}
prtExPhPlFrameSeparator OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
idles (2),
flags (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates what should be transferred on the line when there
are no frames to pass (HDLC item).
idles: mean that FF will pass on the line
flags: mean that 7E will pass on the line."
::= { prtExPhPlCnfgEntry 33}
prtExPhPlIdleCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines the code for transmission when there are no frames to transmit
on the line. The value should be 0 to FFH."
::= { prtExPhPlCnfgEntry 34}
prtExPhPlJitter OBJECT-TYPE
SYNTAX Integer32 (0..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum variant delay of the FR network, in msec."
::= { prtExPhPlCnfgEntry 35}
--
-- PH.1 & PH.3
-- External port Dlci table
--
prtExPhPlDlciTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExPhPlDlciEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
at the TmpCnfg entry."
::= {prtPhPlCnfg 2}
prtExPhPlDlciEntry OBJECT-TYPE
SYNTAX PrtExPhPlDlciEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExPhPlDlciCnfgIdx, prtExPhPlDlciSltIdx, prtExPhPlDlciPrtIdx, prtExPhPlDlciIdx }
::= { prtExPhPlDlciTable 1}
PrtExPhPlDlciEntry ::=
SEQUENCE {
prtExPhPlDlciCnfgIdx Integer32,
prtExPhPlDlciSltIdx INTEGER,
prtExPhPlDlciPrtIdx INTEGER,
prtExPhPlDlciIdx Integer32,
prtExPhPlDlciValid INTEGER,
prtExPhPlDlciIConSlt INTEGER,
prtExPhPlDlciIConPrt INTEGER,
prtExPhPlDlciIConDlci Integer32,
prtExPhPlDlciTxBc INTEGER,
prtExPhPlDlciTxBe INTEGER,
prtExPhPlDlciRxBc INTEGER,
prtExPhPlDlciRxBe INTEGER,
prtExPhPlDlciPriority Integer32,
prtExPhPlDlciStatus INTEGER
}
prtExPhPlDlciCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtExPhPlDlciEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExPhPlDlciSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= { prtExPhPlDlciEntry 2}
prtExPhPlDlciPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique internal port number.
PH.1/E1 and PH.1/T1 cards have three internal ports.
Stand-alone units may have six such ports."
::= { prtExPhPlDlciEntry 3}
prtExPhPlDlciIdx OBJECT-TYPE
SYNTAX Integer32 (1..991)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique index for each possible
used dlci(16..991). When the protocol is not Multiplexing
protocol, its type is 'user' and the only valid index is 1."
::= { prtExPhPlDlciEntry 4}
prtExPhPlDlciValid OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the attributes in this
entry are valid or not. The user can add/delete pvc (dlci
to dlci connection) by modifing this object"
::= { prtExPhPlDlciEntry 5}
prtExPhPlDlciIConSlt OBJECT-TYPE
SYNTAX INTEGER
{
noConnect (2),
cl (3),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position In the Mux
(Agent) where the dlci is routed to.
cl - will represent any of the CL slots. This value can be
selected for multiple DLCIs of the product.
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= { prtExPhPlDlciEntry 6}
prtExPhPlDlciIConPrt OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
clNMS (99),
noConnect (100),
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103) ,
inPrt4 (104) ,
inPrt5 (105) ,
inPrt6 (106) ,
inPrt7 (107) ,
inPrt8 (108) ,
inPrt9 (109) ,
inPrt10 (110)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique port id which the dlci is
routed to.
clNMS - will be used for NMS SNMP messages. It can be any
port of the CL card.
This value will be selectable only if
prtExPhPlDlciIConSlt='cl' or 'notApplicable'."
::= { prtExPhPlDlciEntry 7}
prtExPhPlDlciIConDlci OBJECT-TYPE
SYNTAX Integer32 (1..991)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique internal connection dlci
number, the dlci is routed to."
::= { prtExPhPlDlciEntry 8}
prtExPhPlDlciTxBc OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
txBc9600bps (3),
txBc14400bps (4),
txBc19200bps (5),
txBc28800bps (6),
txBc32000bps (7),
txBc38400bps (8),
txBc48000bps (9),
txBc56000bps (10),
txBc57600bps (11),
txBc64Kbps (12),
txBc128Kbps (13),
txBc192Kbps (14),
txBc256Kbps (15),
txBc320Kbps (16),
txBc384Kbps (17),
txBc448Kbps (18),
txBc512Kbps (19),
txBc768Kbps (20),
txBc1024Kbps (21),
--
--KM30 ; KM300 additional rates
--
txBc16000bps (25),
txBc112Kbps (26)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Tx committed bandwidth on
the user transmit line (or at the port receive line)."
::= { prtExPhPlDlciEntry 9}
prtExPhPlDlciTxBe OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
txBe9600bps (3),
txBe14400bps (4),
txBe19200bps (5),
txBe28800bps (6),
txBe32000bps (7),
txBe38400bps (8),
txBe48000bps (9),
txBe56000bps (10),
txBe57600bps (11),
txBe64Kbps (12),
txBe128Kbps (13),
txBe192Kbps (14),
txBe256Kbps (15),
txBe320Kbps (16),
txBe384Kbps (17),
txBe448Kbps (18),
txBe512Kbps (19),
txBe768Kbps (20),
txBe1024Kbps (21),
--
--KM30 ; KM300 additional rates
--
txBc16000bps (25),
txBc112Kbps (26)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Tx excess bandwidth on the
user transmit line (or at the port receive line)."
::= { prtExPhPlDlciEntry 10}
prtExPhPlDlciRxBc OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
rxBc9600bps (3),
rxBc14400bps (4),
rxBc19200bps (5),
rxBc28800bps (6),
rxBc32000bps (7),
rxBc38400bps (8),
rxBc48000bps (9),
rxBc56000bps (10),
rxBc57600bps (11),
rxBc64Kbps (12),
rxBc128Kbps (13),
rxBc192Kbps (14),
rxBc256Kbps (15),
rxBc320Kbps (16),
rxBc384Kbps (17),
rxBc448Kbps (18),
rxBc512Kbps (19),
rxBc768Kbps (20),
rxBc1024Kbps (21),
--
--KM30 ; KM300 additional rates
--
rxBc16000bps (25),
rxBc112Kbps (26)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Rx committed bandwidth on the
user receive line (or at the port transmit line)."
::= { prtExPhPlDlciEntry 11}
prtExPhPlDlciRxBe OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
rxBe9600bps (3),
rxBe14400bps (4),
rxBe19200bps (5),
rxBe28800bps (6),
rxBe32000bps (7),
rxBe38400bps (8),
rxBe48000bps (9),
rxBe56000bps (10),
rxBe57600bps (11),
rxBe64Kbps (12),
rxBe128Kbps (13),
rxBe192Kbps (14),
rxBe256Kbps (15),
rxBe320Kbps (16),
rxBe384Kbps (17),
rxBe448Kbps (18),
rxBe512Kbps (19),
rxBe768Kbps (20),
rxBe1024Kbps (21),
--
--KM30 ; KM300 additional rates
--
rxBc16000bps (25),
rxBc112Kbps (26)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Rx excess bandwidth on the
user receive line (or at the port transmit line)."
::= { prtExPhPlDlciEntry 12}
prtExPhPlDlciPriority OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique priority of the pcv.
1 is the lowest priority and 8 is the highest priority."
::= { prtExPhPlDlciEntry 13}
prtExPhPlDlciStatus OBJECT-TYPE
SYNTAX INTEGER
{
disconnected (1),
connected (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of the pvc. The status is
disconnected(1) when one of the sides is programmed as not
connected"
::= { prtExPhPlDlciEntry 14}
-- Parameters of an external Modem which is connected to a High/Low Speed
-- Port.
prtExPhPlModemTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExPhPlModemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "External Modem Parameters.
The write operation into the
Table Objects is valid only for the TmpCnfg entry."
::= {prtPhPlCnfg 3}
prtExPhPlModemEntry OBJECT-TYPE
SYNTAX PrtExPhPlModemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExPhPlModemCnfgIdx,prtExPhPlModemSltIdx,prtExPhPlModemPrtIdx}
::= { prtExPhPlModemTable 1}
PrtExPhPlModemEntry ::=
SEQUENCE {
prtExPhPlModemCnfgIdx Integer32,
prtExPhPlModemSltIdx INTEGER,
prtExPhPlModemPrtIdx INTEGER,
prtExPhPlModemStatus INTEGER,
prtExPhPlModemActivate INTEGER,
prtExPhPlModemMaxIdleTime Integer32,
prtExPhPlModemTimeBtwnCalls Integer32,
prtExPhPlModemCallDelay Integer32
}
prtExPhPlModemCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtExPhPlModemEntry 1}
prtExPhPlModemSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid"
::= { prtExPhPlModemEntry 2}
prtExPhPlModemPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
In case of PH.1 card, only exPrt(1) is valid."
::= { prtExPhPlModemEntry 3}
prtExPhPlModemStatus OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3),
relay (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether a Dial Up Modem is enabled on this port.
Default: disable
For Vmux devices this object shows whether there is Modem Relay support."
::= { prtExPhPlModemEntry 4}
prtExPhPlModemActivate OBJECT-TYPE
SYNTAX INTEGER
{
onFirstFrame(2),
always (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the Dial Up Modem is activated when
the first frame is received or it is always activated.
Default: onFirstFrame"
::= { prtExPhPlModemEntry 5}
prtExPhPlModemMaxIdleTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Max Time allowed in Seconds without any traffic before the line
is disconnected.
Legal Values are: 1 sec, 2 sec .. 5 sec, 10 sec, 20 sec..
1 min, 2 min .. 10 min, 15 min, 20 min, 25 min, 30 min.
65535 sec. means that this parameter is not applicable.
Default: 1 sec."
::= { prtExPhPlModemEntry 6}
prtExPhPlModemTimeBtwnCalls OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minimum Time in Seconds which is required after a call was
disconnected. In this time no other call will be initiated
from this Modem port even if there were frames transmitted
to this port. This time is required for some Modems which
have initializations that take a few seconds.
Legal Values are:
0 sec. - 30 sec., 1-5 min.
65535 sec. means that this parameter is not applicable.
Default: 0 sec"
::= { prtExPhPlModemEntry 7}
prtExPhPlModemCallDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time in Seconds that the device will wait before dialing to the remote
device.
This feature is mostly used when there is a backup modem to the
main link and the main link is down. In this case it is important to prevent
the 2 devices from dialing through the backup modems to each other at the same time.
It is advised to configure one side with a small call delay and the other side
with a large call delay.
Legal Values are:
0 - 30, 60, 120, 180, 240, 300, 600, 900, 1200, 1500, 1800 .
65535 sec. means that this parameter is not applicable.
Default: 0 sec"
::= { prtExPhPlModemEntry 8}
--
-- Megaplex ?000/?004 LS-2 TDM I/O family card include:
-- Ls2-CCITT-X.50, Ls2-CCITT-X.58, Ls2-AT&T-SDM
--
--prtExLs2CnfgTable OBJECT IDENTIFIER ::= {prtLs2Cnfg 1}
--prtInLs2CnfgTable OBJECT IDENTIFIER ::= {prtLs2Cnfg 2}
prtExLs2CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExLs2CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtLs2Cnfg 1}
prtExLs2CnfgEntry OBJECT-TYPE
SYNTAX PrtExLs2CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExLs2CnfgIdx, prtExLs2SltIdx, prtExLs2PrtIdx }
::= {prtExLs2CnfgTable 1}
PrtExLs2CnfgEntry ::=
SEQUENCE {
prtExLs2CnfgIdx Integer32,
prtExLs2SltIdx INTEGER,
prtExLs2PrtIdx INTEGER,
prtExLs2Connect INTEGER,
prtExLs2Rate INTEGER,
prtExLs2ClkMode INTEGER,
prtExLs2Cts INTEGER,
prtExLs2Dcd INTEGER,
prtExLs2EnvIdx Integer32
}
prtExLs2CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExLs2CnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExLs2SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid."
::= {prtExLs2CnfgEntry 2}
prtExLs2PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port index.
For the Ls2/X.58 exPrt(7)..exPrt(10) are not valid."
::= {prtExLs2CnfgEntry 3}
prtExLs2Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithms."
::= {prtExLs2CnfgEntry 4}
prtExLs2Rate OBJECT-TYPE
SYNTAX INTEGER
{
r2400bps (2),
r4800bps (3),
r9600bps (4),
r19200bps (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port rates."
::= {prtExLs2CnfgEntry 5}
prtExLs2ClkMode OBJECT-TYPE
SYNTAX INTEGER
{
dce (1),
ext-dce (2),
dte (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique port operation clock mode."
::= {prtExLs2CnfgEntry 6}
prtExLs2Cts OBJECT-TYPE
SYNTAX INTEGER
{
on (2),
rts-min (3),
rts-max (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CTS."
::= {prtExLs2CnfgEntry 7}
prtExLs2Dcd OBJECT-TYPE
SYNTAX INTEGER
{
on (2),
card-sync (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DCD."
::= {prtExLs2CnfgEntry 8}
prtExLs2EnvIdx OBJECT-TYPE
SYNTAX Integer32 (0..24)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Envelope Index.
When prtInLs2EnvAssign=auto, the value is 0 (not applicable)."
::= {prtExLs2CnfgEntry 9}
-- Ls2 Internal composit channel parameters
--
prtInLs2CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInLs2CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtLs2Cnfg 2}
prtInLs2CnfgEntry OBJECT-TYPE
SYNTAX PrtInLs2CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtInLs2CnfgIdx, prtInLs2SltIdx, prtInLs2PrtIdx }
::= {prtInLs2CnfgTable 1}
PrtInLs2CnfgEntry ::=
SEQUENCE {
prtInLs2CnfgIdx Integer32,
prtInLs2SltIdx INTEGER,
prtInLs2PrtIdx INTEGER,
prtInLs2Connect INTEGER,
prtInLs2Group Integer32,
prtInLs2Member Integer32,
prtInLs2LinkTo INTEGER,
prtInLs2EnvAssign INTEGER
}
prtInLs2CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtInLs2CnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtInLs2SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid."
::= {prtInLs2CnfgEntry 2}
prtInLs2PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
inPrt1 (101),
inPrt2 (102)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique internal port index."
::= {prtInLs2CnfgEntry 3}
prtInLs2Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered in
any of the mux algorithms. It also affects all the module
considerations because the module has only one Internal
interface which is the composite channel."
::= {prtInLs2CnfgEntry 4}
prtInLs2Group OBJECT-TYPE
SYNTAX Integer32 (1..12)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the group number of the port.
LS-2 internal ports with the same group number share the same Time slot of the main
link"
::= {prtInLs2CnfgEntry 5}
prtInLs2Member OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the group member id of the port.
This parameter is for the automatic envelope assignment
algorithm."
::= {prtInLs2CnfgEntry 6}
prtInLs2LinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"It indicates the slot of the main link card to which the
LS2 card is mapped.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtInLs2CnfgEntry 7}
prtInLs2EnvAssign OBJECT-TYPE
SYNTAX INTEGER
{
auto (2),
manual (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Envelope assignment type."
::= {prtInLs2CnfgEntry 8}
--
-- Megaplex?000/?004 VC-2, VC-6, VC-2/R2, VC-Q TDM I/O family port.
-- (Vc2E&m,Vc2Fxs1Plar,Vc2Fxo1,Vc2Fxs2,Vc2Fxo2,Vc2Fxs3,Vc2Fxo3)
-- Vc6E&M, Vc6Fxo, Vc6Fxs, Vc6aE&M, Vc6aFxo, Vc6aFxs
-- Vc2/R2(Fxs)
-- VC-Q
-- VC-12, VC-12/6
-- VC-8, VC-16
prtVc2CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtVc2CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"- For products supporting more than one configuration, the write operation
into the Table is valid only to the TmpCnfg entry.
- For products that do not support configurations, the write operation
into the Table will be to prtVc2CnfgIdx=1."
::= { cnfgPrtMux 5}
prtVc2CnfgEntry OBJECT-TYPE
SYNTAX PrtVc2CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtVc2CnfgIdx, prtVc2SltIdx, prtVc2PrtIdx }
::= { prtVc2CnfgTable 1}
PrtVc2CnfgEntry ::=
SEQUENCE {
prtVc2CnfgIdx Integer32,
prtVc2SltIdx INTEGER,
prtVc2PrtIdx Integer32,
prtExVc2Connect INTEGER,
prtExVc2TransGain Integer32,
prtExVc2ReceiveGain Integer32,
prtExVc2Wire INTEGER,
prtExVc2CodingLaw INTEGER,
prtExVc2Sig INTEGER,
prtExVc2Oos INTEGER,
prtExVc2LinkTo INTEGER,
prtExVc2OperMode INTEGER,
prtExVc2SigProfile INTEGER,
prtExVc2CallEnable INTEGER,
prtExVc2R2Delay INTEGER,
prtExVc2CasStd INTEGER,
prtExVc2EchoCanceler INTEGER,
prtExVc2IfType INTEGER,
prtExVc2Encoding INTEGER,
prtExVc2TxBitCode OCTET STRING,
prtExVc2RxBitOutput OCTET STRING,
prtExVc2MeterRate INTEGER,
prtExVc2IfSignaling INTEGER,
prtExVc2SeizeAck INTEGER,
prtExVc2EandMType INTEGER,
prtExVc2RemType INTEGER,
prtExVc2ConvTime INTEGER,
prtExVc2SigFeedback INTEGER,
prtExVc2EchoCancelerModule INTEGER,
prtExVc2ReversePolarity INTEGER,
prtExVc2RingerFrequency INTEGER,
prtExVc2SigService INTEGER,
prtExVc2CallerIdEnable INTEGER,
prtExVc2CompressMethod INTEGER,
prtExVc2ObMode INTEGER,
prtExVc2VAD INTEGER,
prtExVc2NoiseLevelForVAD INTEGER,
prtExVc2WesternSigMode INTEGER,
prtExVc2BusProtectionPoint INTEGER, --not used
prtExVc2ImpedanceStandard INTEGER
}
prtVc2CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtVc2CnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtVc2SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
For Stand Alone products like WR: notApplicable (255)"
::= {prtVc2CnfgEntry 2}
prtVc2PrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port, within the card.
For MP-2100/2200 card ports, Web Ranger and FCD-IP Voice ports
the values will be:
exPrt1 (1)
exPrt2 (2)
exPrt3 (3)
exPrt4 (4)
exPrt5 (5)
exPrt6 (6)
exPrt7 (7)
exPrt8 (8)
exPrt9 (9)
exPrt10 (10)
exPrt11 (11)
exPrt12 (12)
exPrt13 (13)
exPrt14 (14)
exPrt15 (15)
exPrt16 (16)
For LA-240:
The index for fixed voice ports will be -
exPrt6 (6)
exPrt7 (7)
exPrt8 (8)
exPrt9 (9)
The index for voice card ports will be -
Slot number * 100 + ch (for IO-1: 101..104, for IO-2: 201..204).
For other products' index see their specification."
::= {prtVc2CnfgEntry 3}
prtExVc2Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3),
v51 (4),
v52 (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithms."
::= {prtVc2CnfgEntry 4}
prtExVc2TransGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transmit gain in dBm.
For ports of MP-104/204, MP-2100/2200 VC-6A, VC-6AG, VC-8
VC-4/Omni and VC-16 cards, the units will be 0.1dBm because
valid values can be in 0.5dBm steps."
::= {prtVc2CnfgEntry 5}
prtExVc2ReceiveGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Receive gain in dBm.
For ports of MP-104/204, MP-2100/2200 VC-6A, VC-6AG, VC-8
VC-4/Omni and VC-16 cards, the units will be 0.1dBm because
valid values can be in 0.5dBm steps."
::= {prtVc2CnfgEntry 6}
prtExVc2Wire OBJECT-TYPE
SYNTAX INTEGER
{
w2wire (1),
w4wire (2),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For some cards, this object is equal for all the ports in the specific
card because of HW limitations.
For FXO & FXS this parameter is not applicable."
::= {prtVc2CnfgEntry 7}
prtExVc2CodingLaw OBJECT-TYPE
SYNTAX INTEGER
{
aLAW (1),
uLAW (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Method/Law for decoding/encoding the voice
information.
aLaw(1) is the standard Law for E1 links.
uLaw(2) is the standard Law for T1 links.
This object is equal for all the ports in the specific module because
of HW limitations"
::= {prtVc2CnfgEntry 8}
prtExVc2Sig OBJECT-TYPE
SYNTAX INTEGER
{
noSignaling (1),
robbedBitMultiFrame (2),
chAssociatedE1 (3),
robbedBitFrame (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the method for decoding/encoding the signaling
information(on/off hook).
noSignaling (1) - not using signaling (only voice).
robbedBitMultiFrame(2) - is the standard method for T1 links and
proprietary method for E1 links.
chAssociatedE1 (3) - is valid only for E1 G.732S links.
robbedBitFrame (4) - is proprietary method implimenting 7 bit for
the voice and 1 bit dedicated for signaling.
For some cards, this object is equal for all the ports in the specific module
because of HW limitations."
::= {prtVc2CnfgEntry 9}
prtExVc2Oos OBJECT-TYPE
SYNTAX INTEGER
{
forcedIdle (1),
forcedBusy (2),
busyIdle (3),
idleBusy (4),
notApplicable (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is equal for all the ports in the specific card
because of HW limitations"
::= {prtVc2CnfgEntry 10}
prtExVc2LinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This attribute indicates the slot of the ML card to which
the VC card is mapped.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtVc2CnfgEntry 11}
prtExVc2OperMode OBJECT-TYPE
SYNTAX INTEGER
{
normal (2),
unidirectRx (3),
broadcast (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the operation mode of the port.
normal = bi-directional (Tx/Rx)
unidirectRx = unidirectional Rx.
broadcast = Tx upon request."
::= {prtVc2CnfgEntry 12}
prtExVc2SigProfile OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
manual (2),
p1 (3),
p2 (4),
p3Fxo3S3 (5),
reversePolarity (6), --3RP
meteringPulse (7), --3MP
p4 (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Signaling Profile of the port.
notApplicable - for VC-2 family and when
prtExVc2Sig=noSignaling(1)
p1 = profile 1
p2 = profile 2
p3 = profile 3
p4 = profile 4 "
::= {prtVc2CnfgEntry 13}
prtExVc2CallEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
incoming (2),
outgoing (3),
both (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Enabled Call direction.
notApplicable - for all cards except VC-2/R2.
both - incoming + outgoing."
::= {prtVc2CnfgEntry 14}
prtExVc2R2Delay OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
terrestrial (2),
satellite (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the R2 Delay.
notApplicable - for all cards except VC-2/R2."
::= {prtVc2CnfgEntry 15}
prtExVc2CasStd OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
r2Q422 (2),
specialA (3),
specialB (4),
specialC (5),
specialD (6),
specialE (7),
specialF (8),
specialG (9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the CAS (Channel Associated Signaling)
Standard.
notApplicable - for all cards except VC-2/R2."
::= {prtVc2CnfgEntry 16}
prtExVc2EchoCanceler OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Echo canceler activation.
notApplicable - for VC-2 and VC-6 cards."
::= {prtVc2CnfgEntry 17}
prtExVc2IfType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
w2Em (2),
w4Em (3),
fxo (4),
fxs (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Interface Type."
::= {prtVc2CnfgEntry 18}
prtExVc2Encoding OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
pcm (2),
adpcm (3),
linear (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Voice Encoding Mode.
linear - is relevant only for the ports of VC-16A card."
::= {prtVc2CnfgEntry 19}
prtExVc2TxBitCode OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
- - - For MP & FCD - - -
This object represents 4 parameters, by 2 Octets :
Tx D Bit Code-MSB nibble,
Tx C Bit Code- nibble,
Tx B Bit Code- nibble,
Tx A Bit Code-LSB nibble.
Each nibble:
0 hex = 0000 = Not Applicable
1 hex = 0001 = M lead
2 hex = 0010 = M lead inverse
3 hex = 0011 = Reverse Polarity
4 hex = 0100 = Metering Pulse
5 hex = 0101 = Forced 1
6 hex = 0110 = Forced 0
7-F hex - not used (invalid values)
This object will be RO if prtExVc2SigProfile is NOT manual.
- - - For WR II - - -
This object represents the following 4 parameters by 2 Octets:
1. On/Off hook signaling transmission mode from the FXS towards the T1/E1 (MSB nibble 1).
2. Default signaling bits that are not in use (nibble 2).
3. Ring Detection signaling transmission mode from the FXO towards the T1/E1(nibble 3).
4. M (Mouth) Signaling transmission mode from the E&M towards the T1/E1(LSB nibble 4).
Each nibble:
---------------------------------------------------------------------------------------
Value On/Off Hook Default sig. Ring Detect. M (Mouth)
---------------------------------------------------------------------------------------
0 hex = 0000 Not Applicable Not Applicable. Not Applicable Not Applicable
1 hex = 0001 Tx A bit Values 1-3 are Tx A bit Tx A bit
2 hex = 0010 Tx A bit inverse for On/Off Hook Tx A bit inv. Tx A bit inv.
3 hex = 0011 Tx B bit A,B,A Inv,B Inv. Tx B bit Tx B bit
4 hex = 0100 Tx B bit inverse Values 4-7 are Tx B bit inv. Tx B bit inv.
5 hex = 0101 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid
6 hex = 0110 not Used-invalid A, A Inverse. not Used-invalid not Used-invalid
7 hex = 0111 not Used-invalid not Used-invalid not Used-invalid
8 hex = 1000 not Used-invalid Values 8-11 are not Used-invalid not Used-invalid
9 hex = 1001 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid
A hex = 1010 not used-invalid B, B Inverse. not Used-invalid not Used-invalid
B hex = 1011 not used-invalid The Bits order: not Used-invalid not Used-invalid
C-F hex not used-invalid ABCD not Used-invalid not Used-invalid
Default value: 11 11 "
::= {prtVc2CnfgEntry 20}
prtExVc2RxBitOutput OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
- - - For MP (VC-Q card only) & FCD - - -
This object represents 3 parameters by 2 Octets:
Spare -MSB nibble, always=0 hex
E Lead Output - nibble,
Reverse Polarity Output- nibble,
Metering Pulse Output -LSB nibble.
Each nibble:
0 hex = 0000 = Not Applicable
1 hex = 0001 = Rx A bit
2 hex = 0010 = Rx A bit inverse
3 hex = 0011 = Rx B bit
4 hex = 0100 = Rx B bit inverse
5 hex = 0101 = Rx C bit
6 hex = 0110 = Rx C bit inverse
7 hex = 0111 = Rx D bit
8 hex = 1000 = Rx D bit inverse
9 hex = 1001 = none
A-F hex - not used (invalid values)
This object will be RO if prtExVc2SigProfile is NOT manual.
- - - For MP (VC-8, VC-16, VC-16A cards) - - -
This object represents 4 parameters, by 2 Octets :
Tx D Bit Code-MSB nibble,
Tx C Bit Code- nibble,
Tx B Bit Code- nibble,
Tx A Bit Code-LSB nibble.
Each nibble:
0 hex = 0000 = Not Applicable
1 hex = 0001 = not used (invalid value)
2 hex = 0010 = not used (invalid value)
3 hex = 0011 = not used (invalid value)
4 hex = 0100 = not used (invalid value)
5 hex = 0101 = Forced 1
6 hex = 0110 = Forced 0
7-F hex - not used (invalid values)
This object will be RO.
- - - For WR II - - -
This object represents the following 2 parameters in 1 Octet:
1. On/Off hook signaling receive mode from the T1/E1 into the FXS/FXO (MSB nibble 1).
2. E (Ear) Signaling receive mode from the T1/E1 into the E&M (LSB nibble 2).
Each nibble:
---------------------------------------------------------------------------------------
Value On/Off Hook E (Ear)
---------------------------------------------------------------------------------------
0 hex = 0000 Not Applicable Not Applicable
1 hex = 0001 Rx A bit Rx A bit
2 hex = 0010 Rx A bit inverse Rx A bit inverse
3 hex = 0011 Rx B bit Rx B bit
4 hex = 0100 Rx B bit inverse Rx B bit inverse
5-F hex not used-invalid not Used-invalid
Default value: 11 "
::= {prtVc2CnfgEntry 21}
prtExVc2MeterRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
r16Khz (2),
r12Khz (3),
disabled(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry is applicable only for VC-6A/FXO, VC-6A/FXS, VC-8/FXO,
VC-8/FXS, VC-16/FXO and VC-16/FXS.
Meter Rate means rate of Call Meter in Public Phones, in KHz units.
For some cards, the value must be the same for all card's ports."
::= {prtVc2CnfgEntry 22}
prtExVc2IfSignaling OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
loopStart (2),
groundStart (3),
winkStart (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry is applicable only for VC-6A, VC-6AG, VC-8/FXO, VC-8/FXS,
VC-16/FXO and VC-16/FXS cards.
Interface Analog Signaling.
Must be the same for all card's ports.
loopStart - for the usual trunk/phone types.
groundStart - for trunks that need Ground signaling .
winkStart - for trunks that need Reverse Polarity. "
::= {prtVc2CnfgEntry 23}
prtExVc2SeizeAck OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter shows whether the device will acknowledge
a seize signal (On/Off Hook).
When the value is set to yes(3) & the device receives an on/off hook signal
it will transmit back an on/off hook signal.
When the value is set to no(2) & the device receives an on/off hook signal
it will NOT transmit back an on/off hook signal.
Default value for WR FXO: no(2)."
::= {prtVc2CnfgEntry 24}
prtExVc2EandMType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
type1 (2),
type2 (3),
type3 (4),
type5 (5) -- SSDC5
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the signaling type on the E&M analog side.
The analog signaling includes voltage, no. of pins and other parameters."
::= {prtVc2CnfgEntry 25}
prtExVc2RemType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
lb (2),
pbx (3),
e1 (4),
t1 (5), --T1ESF
t1D4 (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Remote Type.
Applicable for VC-6A/4LB card &
for IPMUX-1E Far End Type - E1,T1(T1-ESF) or T1-D4 ."
::= {prtVc2CnfgEntry 26}
prtExVc2ConvTime OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
m2 (2),
m3 (3),
m5 (4),
unlimited (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Conversation Time in minutes.
Applicable for VC-6A/4LB card."
::= {prtVc2CnfgEntry 27}
prtExVc2SigFeedback OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Signaling Feedback.
Applicable for VC-8/FXO and VC-16/FXO cards."
::= {prtVc2CnfgEntry 28}
prtExVc2EchoCancelerModule OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
notExist (2),
exist (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates whether Echo canceler module exists for this port."
::= {prtVc2CnfgEntry 29}
prtExVc2ReversePolarity OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object Enables/Disables Reverse Polarity for this port."
::= {prtVc2CnfgEntry 30}
prtExVc2RingerFrequency OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
f20Hz (2),
f25Hz (3),
f50Hz (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object selects the Ringer Frequency (Hz) for this port."
::= {prtVc2CnfgEntry 31}
prtExVc2SigService OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
normal (2),
advanced (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Signaling Service.
advanced - is relevant only for ports of VC-8, VC-16 FXS cards.
It is used for Signaling Services of V5.1 or R2."
::= {prtVc2CnfgEntry 32}
prtExVc2CallerIdEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object Enables/Disables Receiving the Caller Id number from the
remote side, for this port/channel."
::= {prtVc2CnfgEntry 33}
prtExVc2CompressMethod OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
g726 (2),
g727 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only when prtExVc2Encoding=adpcm.
It defines which method is used for Compression.
g726 - for 4 bits (the standard method).
g726 - for 3 bits. It is especially needed for T1 applications with signaling."
::= {prtVc2CnfgEntry 34}
prtExVc2ObMode OBJECT-TYPE
SYNTAX INTEGER
{
pointToPoint (1),
omniBus (2),
pointToMultiPointSrc(3),
pointToMultiPointDst(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Net operation mode of the Omni-Bus card's port.
pointToPoint - only 2 end-point ports talk; like any other voice card
omniBus - many talk and listen. Like conference call.
All can listen to all.
pointToMultiPointSrc - There is one Master who can be heard by all.
All can talk, but only the Master can hear all. Others can hear
only the Master. This port is of the Master (Src).
pointToMultiPointDst - There is one Master who can be heard by all.
All can talk, but only the Master can hear all. Others can hear
only the Master. This port is of a Destination (NOT Master)."
::= {prtVc2CnfgEntry 35}
prtExVc2VAD OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines whether Voice Activation Detector (VAD)
will be On or Off.
off - will be usually selected when a Modem is connected
to the port; not a phone.
notApplicable - when prtExVc2DspMode=pointToPoint."
::= {prtVc2CnfgEntry 36}
prtExVc2NoiseLevelForVAD OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
low (2),
medium (3),
high (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Level of Noise on the line,
the Voice Activation Detector (VAD) will have to deal with.
notApplicable - when prtExVc2VAD=off."
::= {prtVc2CnfgEntry 37}
prtExVc2WesternSigMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
detector (2),
generator (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Western Signaling Mode.
detector - detects signal and passes it as is.
generator - generates the signal.
notApplicable - when Western HW is not installed."
::= {prtVc2CnfgEntry 38}
prtExVc2BusProtectionPoint OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
no (2),
first (3),
last (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines if the port is Bus Protection Point or not.
notApplicable - when prtExVc2DspMode=pointToPoint.
When we have a chain of devices where the edge devices ports are the
Bus Protection Point, user must configure one of these ports as 'first'
and the other as 'last'. It does not matter which one, it just matters
that they will be different."
::= {prtVc2CnfgEntry 39}
prtExVc2ImpedanceStandard OBJECT-TYPE
SYNTAX INTEGER
{
g712 (1),
q552ETSI (2),
q522Italy(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Standard used for Impedance.
-G.712 - 600 Ohm - used in USA and other countries.
-Q552/ETSI - used in some countries in Europe
-Q522/Italy - used in Italy."
::= {prtVc2CnfgEntry 40}
--
-- Megaplex?000/?004 port specific config for HS(TDM) modules
-- HS-2,HS-3,HS-Q, HS-Q/SC, HS-6, HS-12
--
prtHsfCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtHsfCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { cnfgPrtMux 6}
prtHsfCnfgEntry OBJECT-TYPE
SYNTAX PrtHsfCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtHsfCnfgIdx, prtHsfSltIdx, prtHsfPrtIdx }
::= { prtHsfCnfgTable 1}
PrtHsfCnfgEntry ::=
SEQUENCE {
prtHsfCnfgIdx Integer32,
prtHsfSltIdx INTEGER,
prtHsfPrtIdx INTEGER,
prtExHsfConnect INTEGER,
prtExHsfRate INTEGER,
prtExHsfClkMode INTEGER,
prtExHsfCts INTEGER,
prtExHsfFifoSize INTEGER,
prtExHsfLinkTo INTEGER,
prtExHsfOperMode INTEGER,
prtExHsfInbandLoopback INTEGER,
prtExHsfClkPolarity INTEGER,
prtExHsfControlSignal INTEGER,
prtExHsfBcastRingSrcPort INTEGER
}
prtHsfCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relate to the TmpCnfg. "
::= {prtHsfCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtHsfSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid."
::= {prtHsfCnfgEntry 2}
prtHsfPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
exPrt11 (11) ,
exPrt12 (12) ,
inPrt1 (101) ,
inPrt2 (102)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique external port index.
Hs2 has only two ports (exPrt1,exPrt2).
Hs3 has three ports (exPrt1,exPrt2,exPrt3).
Hsq and hsqN has four ports.
Hs6 has six external ports.
Hs12 has twelve external ports.
inPrt1, inPrt2 - are relevant for VID card."
::= {prtHsfCnfgEntry 3}
prtExHsfConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithms."
::= {prtHsfCnfgEntry 4}
prtExHsfRate OBJECT-TYPE
SYNTAX INTEGER
{
r1x56eq56Kbps (1),
r1x64eq64Kbps (2),
r2x56eq112Kbps (3),
r2x64eq128Kbps (4),
r3x56eq168Kbps (5),
r3x64eq192Kbps (6),
r4x56eq224Kbps (7),
r4x64eq256Kbps (8),
r5x56eq280Kbps (9),
r5x64eq320Kbps (10),
r6x56eq336Kbps (11),
r6x64eq384Kbps (12),
r7x56eq392Kbps (13),
r7x64eq448Kbps (14),
r8x56eq448Kbps (15),
r8x64eq512Kbps (16),
r9x56eq504Kbps (17),
r9x64eq576Kbps (18),
r10x56eq560Kbps (19),
r10x64eq640Kbps (20),
r11x56eq616Kbps (21),
r11x64eq704Kbps (22),
r12x56eq672Kbps (23),
r12x64eq768Kbps (24),
r13x56eq728Kbps (25),
r13x64eq832Kbps (26),
r14x56eq784Kbps (27),
r14x64eq896Kbps (28),
r15x56eq840Kbps (29),
r15x64eq960Kbps (30),
r16x56eq896Kbps (31),
r16x64eq1024Kbps(32),
r17x56eq952Kbps (33),
r17x64eq1088Kbps(34),
r18x56eq1008Kbps(35),
r18x64eq1152Kbps(36),
r19x56eq1064Kbps(37),
r19x64eq1216Kbps(38),
r20x56eq1120Kbps(39),
r20x64eq1280Kbps(40),
r21x56eq1176Kbps(41),
r21x64eq1344Kbps(42),
r22x56eq1232Kbps(43),
r22x64eq1408Kbps(44),
r23x56eq1288Kbps(45),
r23x64eq1472Kbps(46),
r24x56eq1344Kbps(47),
r24x64eq1536Kbps(48),
r25x56eq1400Kbps(49),
r25x64eq1600Kbps(50),
r26x56eq1456Kbps(51),
r26x64eq1664Kbps(52),
r27x56eq1512Kbps(53),
r27x64eq1728Kbps(54),
r28x56eq1568Kbps(55),
r28x64eq1792Kbps(56),
r29x56eq1624Kbps(57),
r29x64eq1856Kbps(58),
r30x56eq1680Kbps(59),
r30x64eq1920Kbps(60),
r31x56eq1736Kbps(61),
r31x64eq1984Kbps(62),
r32Kbps (63)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the port speed. "
::= {prtHsfCnfgEntry 5}
prtExHsfClkMode OBJECT-TYPE
SYNTAX INTEGER
{
dce (1),
ext-dce (2),
dte (3),
none (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique port operation clock mode."
::= { prtHsfCnfgEntry 6}
prtExHsfCts OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
on (2),
rts (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique CTS control line
operation mode."
::= {prtHsfCnfgEntry 7}
prtExHsfFifoSize OBJECT-TYPE
SYNTAX INTEGER
{
auto (2),
s16bits (3),
s30bits (4),
s52bits (5),
s72bits (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Size in bits."
::= {prtHsfCnfgEntry 8}
prtExHsfLinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This attribute indicates a slot of Main Link module, that the
port is linked to. This object is the same for all the
ports in the specific card because of HW limitations.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtHsfCnfgEntry 9}
prtExHsfOperMode OBJECT-TYPE
SYNTAX INTEGER
{
normal (2),
unidirectRx (3),
broadcast (4),
bidirBcastRing (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the operation mode of the port.
normal = bi-directional (Tx/Rx)
unidirectRx = unidirectional Rx.
broadcast = Tx upon request.
bidirBcastRing = Bidirectional Broadcast Ring. When this value is selected,
AND RTS=On, the port opens its transmission channel."
::= {prtHsfCnfgEntry 10}
prtExHsfInbandLoopback OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disabled (2),
ft1Enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if Inband Loopback from the Network
should be enabled or disabled."
::= {prtHsfCnfgEntry 11}
prtExHsfClkPolarity OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
normal (2),
invert (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the clock polarity.
For FCD-M this object will be applicable only for the fixed HS port
(the fixed port on the device)."
::= {prtHsfCnfgEntry 12}
prtExHsfControlSignal OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
local (2),
endToEnd (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Control Signal according to G.797 ITU-T standard.
For FCD-M this object will be applicable for the fixed HS port
(the fixed port on the device) and HS-Q/N channels.
Local and End to End are applicable only when channel Interface type is RS-530,
else it will be Not Applicable."
::= {prtHsfCnfgEntry 13}
prtExHsfBcastRingSrcPort OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
exPrt11 (11) ,
exPrt12 (12) ,
none (100) ,
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only when prtExHsfOperMode=
bidirBcastRing. In this case, the values mean:
- none - this port will be connected to ML in TSA as usual.
- exPrt1.. exPrtX ; X=maximum ports of the card in focus :
it means that the same TS that is assigned in TSA to this port
is actually connected also to this port, for Broadcast Ring mode.
Therefore, this port should NOT be connected to ML in TSA."
::= {prtHsfCnfgEntry 14}
--
-- Megaplex?000/?004 Hs-4/1(HS4T1) HS-4/2(HS4E1) port configuration
--
--prtExHs4CnfgTable OBJECT IDENTIFIER ::= {prtHs4Cnfg 1}
--prtExHs4TsCnfgTable OBJECT IDENTIFIER ::= {prtHs4Cnfg 2}
prtExHs4CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExHs4CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtHs4Cnfg 1}
prtExHs4CnfgEntry OBJECT-TYPE
SYNTAX PrtExHs4CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExHs4CnfgIdx, prtExHs4SltIdx, prtExHs4PrtIdx }
::= { prtExHs4CnfgTable 1}
PrtExHs4CnfgEntry ::=
SEQUENCE {
prtExHs4CnfgIdx Integer32,
prtExHs4SltIdx INTEGER,
prtExHs4PrtIdx INTEGER,
prtExHs4Connect INTEGER,
prtExHs4LineType INTEGER,
prtExHs4LineCode INTEGER,
prtExHs4LineLen INTEGER,
prtExHs4RestoreT INTEGER,
prtExHs4OosSig INTEGER,
prtExHs4OosCode INTEGER,
prtExHs4IdleCode Integer32,
prtExHs4MfClkSrcSlt INTEGER,
prtExHs4MfClkSrcPrt INTEGER
}
prtExHs4CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExHs4CnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExHs4SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted."
::= {prtExHs4CnfgEntry 2}
prtExHs4PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port, within the card."
::= {prtExHs4CnfgEntry 3}
prtExHs4Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithm. It also affects
all the module considerations because the card has only
one external (physical) interface."
::= {prtExHs4CnfgEntry 4}
prtExHs4LineType OBJECT-TYPE
SYNTAX INTEGER
{
esfT1 (2), --> dsx1ESF
sfT1 (3), --> dsx1D4
g732nE1 (4), --> dsx1E1
g732nE1CRC (5), --> dsx1E1-CRC
g732sE1 (6), --> dsx1E1-MF
g732sE1CRC (7) --> dsx1E1-MF-CRC
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the line type parameter for T1/E1
interface.
The user should select only the parameters relevant to the
specific card:
T1 line code parameters for the HS-4/1 and
E1 line code parameters for the HS-4/2.
This parameter has the same values as dsx1LineType in T1/E1
MIB (RFC-1406). The parameters in dsx1LineType are:
other (1)
dsx1ESF (2)
dsx1D4 (3)
dsx1E1 (4)
dsx1E1-CRC (5)
dsx1E1-MF (6)
dsx1E1-MF-CRC (7)"
::= {prtExHs4CnfgEntry 5}
prtExHs4LineCode OBJECT-TYPE
SYNTAX INTEGER
{
b7T1 (1), --> dsx1JBZS
b8zsT1 (2), --> dsx1B8ZS
hdb3E1 (4) --> dsx1HDB3
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the line code parameter used for T1/E1
interface.
The user should select only the parameters relevant to the
specific card:
T1 line code parameters for the MPH.1/T1 and
E1 line code parameters for the MPH.1/E1.
This parameter has the same values as dsx1LineCoding in T1/E1
MIB (RFC-1406). The parameters in dsx1LineCoding are:
dsx1JBZS (1)
dsx1B8ZS (2)
dsx1HDB3 (3)
dsx1ZBTSI (4)
dsx1AMI (5)
other (6)"
::= {prtExHs4CnfgEntry 6}
prtExHs4LineLen OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
len0p133ft (2),
len134p266ft (3),
len267p399ft (4),
len400p533ft (5),
len534p655ft (6),
fcc68 (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the line length parameter used only for
T1 interfaces.
len399p533ft=len-399-533ft "
::= {prtExHs4CnfgEntry 7}
prtExHs4RestoreT OBJECT-TYPE
SYNTAX INTEGER
{
restoreT1secFast (2),
restoreT10sec62411 (3),
ccittE1 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time passing from the disappearance of the loss of
synchronization condition (red alarm), to the restoration
of normal service."
::= {prtExHs4CnfgEntry 8}
prtExHs4OosSig OBJECT-TYPE
SYNTAX INTEGER
{
notsupported (2),
forcedIdle (3),
forcedBusy (4),
busyIdle (5),
idleBusy (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Out of Service signal type."
::= {prtExHs4CnfgEntry 9}
prtExHs4OosCode OBJECT-TYPE
SYNTAX INTEGER
{
notsupported (2),
oosCode00H (3),
oosCode1aH (4),
oosCode54H (5),
oosCode7eH (6),
oosCode7fH (7),
oosCode98H (8),
oosCode9eH (9),
oosCoded5H (10),
oosCodee4H (11),
oosCodeffH (12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OOS Code"
::= {prtExHs4CnfgEntry 10}
prtExHs4IdleCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Type value(00 - FF HEX), excluding 0H,8H,10H,12H,21H,24H,
42H,49H,84H,92H"
::= {prtExHs4CnfgEntry 11}
prtExHs4MfClkSrcSlt OBJECT-TYPE
SYNTAX INTEGER
{
local (2),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port Tx is multiframe
synchronized with Rx multiframe of another port and the slot position of that port.
This opration is required in order to bypass signaling of PCM
voice channels.
When its value is Local(2) there is no meaning to 'prtExHs4MfClkSrcPrt'
parameter.
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= {prtExHs4CnfgEntry 12}
prtExHs4MfClkSrcPrt OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
inPrt1 (101)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique number to identify a port position in the mux if the
MultiFrame clock source is valid (YES).
inPrt1 - for MTML-H/E1 cards."
::= {prtExHs4CnfgEntry 13}
--
-- Hs4 Time Slot Config Table
--
prtExHs4TsCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExHs4TsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtHs4Cnfg 2}
prtExHs4TsEntry OBJECT-TYPE
SYNTAX PrtExHs4TsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExHs4TsCnfgIdx, prtExHs4TsSltIdx, prtExHs4TsPrtIdx, prtExHs4TsIdx }
::= { prtExHs4TsCnfgTable 1}
PrtExHs4TsEntry ::=
SEQUENCE {
prtExHs4TsCnfgIdx Integer32,
prtExHs4TsSltIdx INTEGER,
prtExHs4TsPrtIdx INTEGER,
prtExHs4TsIdx Integer32,
prtExHs4TsIConSlot INTEGER,
prtExHs4TsIConPrt INTEGER,
prtExHs4TsIConTs Integer32
}
prtExHs4TsCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtExHs4TsEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExHs4TsSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= { prtExHs4TsEntry 2}
prtExHs4TsPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
Hs4/T1 and Hs4/T1 cards have only one external interface."
::= { prtExHs4TsEntry 3}
prtExHs4TsIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique time slot position.
The valid time slots are:
1..24 for T1 Card and
1..31 for E1 interface.
In G732S-E1 lines, time slot 16 is not valid for data,
it is dedicated to multiframe synchronization bits
and voice signaling."
::= { prtExHs4TsEntry 4}
prtExHs4TsIConSlot OBJECT-TYPE
SYNTAX INTEGER
{
noConnect (2),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
split (100)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the specified time slot is
connected/routed internally in the Agent and to which card
it is connected.
In the ?004 Unit the entries io6(10)..io16) are not valid.
split - will be used when the Src TS is connected to more
than one slot OR more than one port (each needing
less than a whole TS)."
::= {prtExHs4TsEntry 5}
prtExHs4TsIConPrt OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
exPrt11 (11) ,
exPrt12 (12) ,
noConnect (100)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the internally (In Mux)
connected/routed port."
::= {prtExHs4TsEntry 6}
prtExHs4TsIConTs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique time slot position.
The valid time slots are:
1..24 for T1 Module and
1..31 for E1 interface.
In G732S-E1 lines time slot 16 is not valid for data,
it is dedicated for multiframe synchronization bits
and voice signaling."
::= { prtExHs4TsEntry 7}
--
-- Megaplex?000/?004 and DXC Hs-U port configuration
--
--prtExHsiCnfgTable OBJECT IDENTIFIER ::= {prtHsiCnfg 1}
prtExHsiCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExHsiCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtHsiCnfg 1}
prtExHsiCnfgEntry OBJECT-TYPE
SYNTAX PrtExHsiCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExHsiCnfgIdx, prtExHsiSltIdx, prtExHsiPrtIdx }
::= { prtExHsiCnfgTable 1}
PrtExHsiCnfgEntry ::=
SEQUENCE {
prtExHsiCnfgIdx Integer32,
prtExHsiSltIdx INTEGER,
prtExHsiPrtIdx Integer32,
prtExHsiConnect INTEGER,
prtExHsiRate INTEGER,
prtExHsiLinkTo INTEGER,
prtExHsiInterface INTEGER,
prtExHsiActType INTEGER
}
prtExHsiCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExHsiCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExHsiSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted."
::= {prtExHsiCnfgEntry 2}
prtExHsiPrtIdx OBJECT-TYPE
SYNTAX Integer32
-- {
-- exPrt1 (1),
-- exPrt2 (2),
-- exPrt3 (3),
-- exPrt4 (4),
-- exPrt5 (5),
-- exPrt6 (6),
-- exPrt7 (7),
-- exPrt8 (8),
-- exPrt9 (9),
-- exPrt10 (10),
-- exPrt11 (11),
-- exPrt12 (12)
-- }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique port identifier within the card.
For MP : 1..12
For DXC: 111 .. 2531. See DXC R6 spec for port index convention.
For FCD-A, 'S' Interface external ports: 131, 141, 151, 161."
::= {prtExHsiCnfgEntry 3}
prtExHsiConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3),
v51 (4),
v52 (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered in
any of the mux algorithms.
v51 - this port is connected to a V5.1 interface. All rest of the
values will be 'notApplicable' in this case. V5 MIB will be
used instead.
v52 - this port is connected to a V5.2 interface. All rest of the
values will be 'notApplicable' in this case. V5 MIB will be
used instead."
::= {prtExHsiCnfgEntry 4}
prtExHsiRate OBJECT-TYPE
SYNTAX INTEGER
{
r600bps (2),
r1200bps (3),
r2400bps (4),
r4800bps (5),
r9600bps (6),
r19200bps (7),
r38400bps (8),
r48kbps (9),
r56kbps (10),
r64kbps (11),
r128kbps (12),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the port speed."
::= {prtExHsiCnfgEntry 5}
prtExHsiLinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"It indicates the slot of the main link card to which the HS-? card
is mapped.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtExHsiCnfgEntry 6}
prtExHsiInterface OBJECT-TYPE
SYNTAX INTEGER
{
lt (1),
nt (2),
te (3),
lt1 (4),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It indicates the interface type:
lt = line termination
nt = network termination
te = terminal equipment.
lt1 - for ASMi-31 connection (not ISDN)
For MP:
For HS-U/I only 'lt' and 'nt' are applicable.
For HS-U/1 only 'lt' is applicable.
For HS-S , only 'te' and 'nt' are applicable.
For HS-U, this object is not applicable.
For HS-U6, HS-U12, are applicable: 'lt'=lt-i,'nt'=nt-i, lt1.
For DXC:
For HS-U8, HS-U16, are applicable: 'lt'=LT-I,'nt'=NT-I, 'lt1'=LT-1."
::= {prtExHsiCnfgEntry 7}
prtExHsiActType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
type1 (2),
type2 (3),
type3 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It indicates the Activation Type. Activation Type is the Synchronization
type towards the PBX. It is applicable only when prtExHsiInterface=nt.
notApplicable - for cards that do not support this object, or when
prtExHsiInterface is NOT nt."
::= {prtExHsiCnfgEntry 8}
--prtInHsiCnfgTable OBJECT IDENTIFIER ::= {prtHsiCnfg 2}
--This table is not applicable for MP-2100 HS-U card type
prtInHsiCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInHsiCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry.
This table is not applicable for MP-2100 HS-U card type."
::= {prtHsiCnfg 2}
prtInHsiCnfgEntry OBJECT-TYPE
SYNTAX PrtInHsiCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtInHsiCnfgIdx, prtInHsiSltIdx, prtInHsiPrtIdx }
::= { prtInHsiCnfgTable 1}
PrtInHsiCnfgEntry ::=
SEQUENCE {
prtInHsiCnfgIdx Integer32,
prtInHsiSltIdx INTEGER,
prtInHsiPrtIdx Integer32,
prtInHsiConnect INTEGER,
prtInHsiRate INTEGER,
prtInHsiConcentratedTo Integer32
}
prtInHsiCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtInHsiCnfgEntry 1}
prtInHsiSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique slot position where
the card is inserted."
::= {prtInHsiCnfgEntry 2}
prtInHsiPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique port identifier within the card.
Valid values for MP: inPrt1 (101) .. inPrt48 (148).
Valid values for DXC: 11012.. 25316. See DXC R6 spec for port index convention."
::= {prtInHsiCnfgEntry 3}
prtInHsiConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered in
any of the mux algorithms."
::= {prtInHsiCnfgEntry 4}
prtInHsiRate OBJECT-TYPE
SYNTAX INTEGER
{
r600bps (2),
r1200bps (3),
r2400bps (4),
r4800bps (5),
r9600bps (6),
r19200bps (7),
r38400bps (8),
r48kbps (9),
r56kbps (10),
r64kbps (11),
r128kbps (12),
concentrated (13),
notConnected (100),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the port speed.
For HS-U/I and HS-S ports:
2 bit - up to 9600bps
4 bit - 19200bps
8 bit - 38400bps .. 64kbps.
concentrated - this D channel goes to a Concentration channel,
that represents many channels that this value was
selected for them. The Concentrated channel is an
Internal D Channel of the same card.
This value is applicable only for D channels, except
Concentration channel itself.
--for HS-S and HS-U/I cards the Concentration channel
will always be: internal-13
--for MP-2200 HS-S12, HS-S6, HS-U12, HS-U6 and
DXC HS-U8 and HS-U16 cards, the Concentration channel
is selected via the prtInHsiConcentratedTo object.
notConnected - same as prtInHsiConnect=no."
::= {prtInHsiCnfgEntry 5}
prtInHsiConcentratedTo OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Concentration D Channel of the prtInHsiPrtIdx port.
The port always belongs to the same card as prtInHsiPrtIdx port.
This object is applicable only when prtInHsiRate=concentrated.
Valid values:
- notApplicable: 255
- for MP-2200: HS-S12, HS-U12 cards: inPrt37 (137) .. inPrt48 (148).
HS-S6, HS-U6 cards: inPrt19 (119) .. inPrt24 (124).
- for DXC: HS-U8 cards: 112 .. 254
HS-U16 cards: 112 .. 258. See DXC R6 spec for port index
convention."
::= {prtInHsiCnfgEntry 6}
--
-- Megaplex?000/?004 Hs-R and HS-U port configuration
-- DXC HS-U8, HS-U16 port configuration for Interface=LT-1
--
--prtExHsrCnfgTable OBJECT IDENTIFIER ::= {prtHsrCnfg 1}
prtExHsrCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExHsrCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtHsrCnfg 1}
prtExHsrCnfgEntry OBJECT-TYPE
SYNTAX PrtExHsrCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExHsrCnfgIdx, prtExHsrSltIdx, prtExHsrPrtIdx }
::= { prtExHsrCnfgTable 1}
PrtExHsrCnfgEntry ::=
SEQUENCE {
prtExHsrCnfgIdx Integer32,
prtExHsrSltIdx INTEGER,
prtExHsrPrtIdx Integer32,
prtExHsrConnect INTEGER,
prtExHsrProtocol INTEGER,
prtExHsrRate INTEGER,
prtExHsrDataBits INTEGER,
prtExHsrParity INTEGER,
prtExHsrStopBits INTEGER,
prtExHsrCts INTEGER,
prtExHsrClkMode INTEGER,
prtExHsrLinkTo INTEGER,
prtExHsrDcdDsr INTEGER,
prtExHsrOperMode INTEGER,
prtExHsrRtsDtr INTEGER,
prtExHsrLlbEnable INTEGER,
prtExHsrRlbEnable INTEGER,
prtExHsrRateAdapt INTEGER,
prtExHsrRemoteModem INTEGER ,
prtExHsrEncapsMode INTEGER
}
prtExHsrCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExHsrCnfgEntry 1}
prtExHsrSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique slot position where
the card is inserted."
::= {prtExHsrCnfgEntry 2}
prtExHsrPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique prt identifier within the card.
Valid values:
For MP:
- For HS-R cards: exPrt1 (1) .. exPrt4 (4)
- For HS-U/1 cards: inPrt1 (101) .. inPrt4 (104)
- For HS-S12, HS-S6, HS-U12, HS-U6 cards:
exPrt1 (1) .. exPrt12 (12).
This MIB table is used only for LT-1 interface.
For DXC:
- For HS-U8, HS-U16 cards:
111 .. 2531 (See DXC R6 spec for port index convention).
This MIB table is used only for LT-1 interface."
::= {prtExHsrCnfgEntry 3}
prtExHsrConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the port should be considered in
any of the mux algorithms."
::= {prtExHsrCnfgEntry 4}
prtExHsrProtocol OBJECT-TYPE
SYNTAX INTEGER
{
sync (2),
async (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the protocol."
::= {prtExHsrCnfgEntry 5}
prtExHsrRate OBJECT-TYPE
SYNTAX INTEGER
{
r600bps (2),
r1200bps (3),
r2400bps (4),
r4800bps (5),
r9600bps (6),
r19200bps (7),
r38400bps (8),
r48kbps (9),
r56kbps (10),
r64kbps (11),
r16000bps (12),
r32000bps (13),
r57600bps (14),
r115200bps(15),
r128000bps(16),
r7200bps (17),
r14400bps (18),
r28800bps (19),
notConnected (100)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the port speed.
The 16,32,48,56,64 and 128 kbps rates are applicable only for Sync
protocol.
The 57.6 and 115.2 kbps rates are applicable only for Async
protocol.
notConnected= 0 rate."
::= {prtExHsrCnfgEntry 6}
prtExHsrDataBits OBJECT-TYPE
SYNTAX INTEGER
{
d5bits (1),
d6bits (2),
d7bits (3),
d8bits (4),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data Bits.
This object is applicable for Async protocol only."
::= {prtExHsrCnfgEntry 7}
prtExHsrParity OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3),
odd (4),
even(5),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"- For HS-R card, this object indicates if the parity bit is needed or not.
Therefore, the 'no' and 'yes; values are applicable.
- For HS-S12, HS-U12, the parity type is selected: no, odd, even.
This object is applicable for Async protocol only."
::= { prtExHsrCnfgEntry 8}
prtExHsrStopBits OBJECT-TYPE
SYNTAX INTEGER
{
stopBits1Bit (1),
stopBits2Bits (2),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the minimum number of stop bits in
the tx async frame.
This object is applicable for Async protocol only."
::= { prtExHsrCnfgEntry 9}
prtExHsrCts OBJECT-TYPE
SYNTAX INTEGER
{
on (2),
rts (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CTS.
This object is applicable for Async protocol only."
::= {prtExHsrCnfgEntry 10}
prtExHsrClkMode OBJECT-TYPE
SYNTAX INTEGER
{
dce (1),
extDce (2),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock mode.
This object is applicable for Sync protocol only."
::= { prtExHsrCnfgEntry 11}
prtExHsrLinkTo OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"It indicates the slot of the main link card to which the HS-R card
is mapped.
notApplicable - for HS-U/1 internal ports.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtExHsrCnfgEntry 12}
prtExHsrDcdDsr OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
local (2),
endToEnd (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DCD & DSR."
::= {prtExHsrCnfgEntry 13}
prtExHsrOperMode OBJECT-TYPE
SYNTAX INTEGER
{
normal (2),
unidirectRx (3),
broadcast (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the operation mode of the port.
normal = bi-directional (Tx/Rx)
unidirectRx = unidirectional Rx.
broadcast = Tx upon request."
::= {prtExHsrCnfgEntry 14}
prtExHsrRtsDtr OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
local (2),
endToEnd (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RTS & DTR."
::= {prtExHsrCnfgEntry 15}
prtExHsrLlbEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable LLB."
::= {prtExHsrCnfgEntry 16}
prtExHsrRlbEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable RLB."
::= {prtExHsrCnfgEntry 17}
prtExHsrRateAdapt OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
proprietary (2),
v110 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Rate Adaptation - takes a low rate and adapts it to 64Kbps.
This object specifies the means this adaptation is done by."
::= {prtExHsrCnfgEntry 18}
prtExHsrRemoteModem OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
asmi31 (2),
asmi31s2 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Remote modem.
asmi31s2 = ASMi-31/2 "
::= {prtExHsrCnfgEntry 19}
prtExHsrEncapsMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
bwOptimized (2),
latencyOptimized (3),
asmi31 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low Speed encapsulation method over PCM.
When Encapsulation mode is Latency optimized, only rates up to 19.2 are supported.
In this case a double number of bits occupy the Time Slot.
For up to 9.6 Kbps - 4 bits are occupied.
For 14.4 & 19.2 Kbps - 8 bits are occupied.
When Encapsulation Mode is Bandwidth Optimized:
For up to 9.6 Kbps - 2 bits are occupied.
For 14.4 & 19.2 Kbps - 4 bits are occupied.
For higher rates - 8 bits are occupied."
::= {prtExHsrCnfgEntry 20}
--
-- Megaplex?000/?004 MBE port configuration
--
prtExMbeCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExMbeCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtMbeCnfg 1}
prtExMbeCnfgEntry OBJECT-TYPE
SYNTAX PrtExMbeCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExMbeCnfgIdx, prtExMbeSltIdx, prtExMbePrtIdx }
::= { prtExMbeCnfgTable 1}
PrtExMbeCnfgEntry ::=
SEQUENCE {
prtExMbeCnfgIdx Integer32,
prtExMbeSltIdx INTEGER,
prtExMbePrtIdx INTEGER,
prtExMbeLan INTEGER
}
prtExMbeCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExMbeCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExMbeSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid."
::= {prtExMbeCnfgEntry 2}
prtExMbePrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique port identifier within the card."
::= {prtExMbeCnfgEntry 3}
prtExMbeLan OBJECT-TYPE
SYNTAX INTEGER
{
remote (1),
main (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the MBE port is operated
as main or remote bridge."
::= {prtExMbeCnfgEntry 4}
prtInMbeCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInMbeCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtMbeCnfg 2}
prtInMbeCnfgEntry OBJECT-TYPE
SYNTAX PrtInMbeCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtInMbeCnfgIdx, prtInMbeSltIdx, prtInMbePrtIdx }
::= { prtInMbeCnfgTable 1}
PrtInMbeCnfgEntry ::=
SEQUENCE {
prtInMbeCnfgIdx Integer32,
prtInMbeSltIdx INTEGER,
prtInMbePrtIdx INTEGER,
prtInMbeConnect INTEGER,
prtInMbeRate INTEGER,
prtInMbeLinkTo INTEGER
}
prtInMbeCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtInMbeCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtInMbeSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid."
::= {prtInMbeCnfgEntry 2}
prtInMbePrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
inPrt1 (101)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique port identifier within the card."
::= {prtInMbeCnfgEntry 3}
prtInMbeConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered in
any of the mux algorithms."
::= {prtInMbeCnfgEntry 4}
prtInMbeRate OBJECT-TYPE
SYNTAX INTEGER
{
r1x64eq64Kbps (1),
r2x64eq128Kbps (2),
r3x64eq192Kbps (3),
r4x64eq256Kbps (4),
r5x64eq320Kbps (5),
r6x64eq384Kbps (6),
r7x64eq448Kbps (7),
r8x64eq512Kbps (8),
r9x64eq576Kbps (9),
r10x64eq640Kbps (10),
r11x64eq704Kbps (11),
r12x64eq768Kbps (12),
r13x64eq832Kbps (13),
r14x64eq896Kbps (14),
r15x64eq960Kbps (15),
r16x64eq1024Kbps(16),
r17x64eq1088Kbps(17),
r18x64eq1152Kbps(18),
r19x64eq1216Kbps(19),
r20x64eq1280Kbps(20),
r21x64eq1344Kbps(21),
r22x64eq1408Kbps(22),
r23x64eq1472Kbps(23),
r24x64eq1536Kbps(24)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the port speed."
::= {prtInMbeCnfgEntry 5}
prtInMbeLinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"It indicates the slot of the main link card to which the
MBE card is mapped.
In the ?004 Unit the entries io6(10)..io16) are not valid.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtInMbeCnfgEntry 6}
--
-- Megaplex?000/?004 TRE port configuration
--
prtExTreCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExTreCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtTreCnfg 1}
prtExTreCnfgEntry OBJECT-TYPE
SYNTAX PrtExTreCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExTreCnfgIdx, prtExTreSltIdx, prtExTrePrtIdx }
::= { prtExTreCnfgTable 1}
PrtExTreCnfgEntry ::=
SEQUENCE {
prtExTreCnfgIdx Integer32,
prtExTreSltIdx INTEGER,
prtExTrePrtIdx INTEGER,
prtExTreLan INTEGER,
prtExTreLanRate INTEGER
}
prtExTreCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExTreCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExTreSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid."
::= {prtExTreCnfgEntry 2}
prtExTrePrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique port identifier within the card."
::= {prtExTreCnfgEntry 3}
prtExTreLan OBJECT-TYPE
SYNTAX INTEGER
{
remote (1),
main (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the TRE port is operated
as main or remote bridge.
Default=remote."
::= {prtExTreCnfgEntry 4}
prtExTreLanRate OBJECT-TYPE
SYNTAX INTEGER
{
r4M (1),
r16M (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Rate of the TRE port
in Mbit/sec.
Default-r4M."
::= {prtExTreCnfgEntry 5}
prtInTreCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInTreCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtTreCnfg 2}
prtInTreCnfgEntry OBJECT-TYPE
SYNTAX PrtInTreCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtInTreCnfgIdx, prtInTreSltIdx, prtInTrePrtIdx }
::= { prtInTreCnfgTable 1}
PrtInTreCnfgEntry ::=
SEQUENCE {
prtInTreCnfgIdx Integer32,
prtInTreSltIdx INTEGER,
prtInTrePrtIdx INTEGER,
prtInTreConnect INTEGER,
prtInTreRate INTEGER,
prtInTreLinkTo INTEGER
}
prtInTreCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtInTreCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtInTreSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid."
::= {prtInTreCnfgEntry 2}
prtInTrePrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
inPrt1 (101)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique port identifier within the card."
::= {prtInTreCnfgEntry 3}
prtInTreConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered
in any of the mux algorithms."
::= {prtInTreCnfgEntry 4}
prtInTreRate OBJECT-TYPE
SYNTAX INTEGER
{
r1x56eq56Kbps (1),
r1x64eq64Kbps (2),
r2x56eq112Kbps (3),
r2x64eq128Kbps (4),
r3x56eq168Kbps (5),
r3x64eq192Kbps (6),
r4x56eq224Kbps (7),
r4x64eq256Kbps (8),
r5x56eq280Kbps (9),
r5x64eq320Kbps (10),
r6x56eq336Kbps (11),
r6x64eq384Kbps (12),
r7x56eq392Kbps (13),
r7x64eq448Kbps (14),
r8x56eq448Kbps (15),
r8x64eq512Kbps (16),
r9x56eq504Kbps (17)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the port speed."
::= {prtInTreCnfgEntry 5}
prtInTreLinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"It indicates the slot of the main link card to which the
MBE card is mapped.
In the ?004 Unit the entries io6(10)..io16) are not valid.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtInTreCnfgEntry 6}
-- Packet VC cards.
-- This table is used for compressed voice cards with 4/8 ports.
--
prtExPVc4CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExPVc4CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { prtPVc4Cnfg 1}
prtExPVc4CnfgEntry OBJECT-TYPE
SYNTAX PrtExPVc4CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExPVc4CnfgIdx, prtExPVc4SltIdx, prtExPVc4PrtIdx }
::= { prtExPVc4CnfgTable 1}
PrtExPVc4CnfgEntry ::=
SEQUENCE {
prtExPVc4CnfgIdx Integer32,
prtExPVc4SltIdx INTEGER,
prtExPVc4PrtIdx INTEGER,
prtExPVc4PrtType INTEGER,
prtExPVc4Connect INTEGER,
prtExPVc4IfType INTEGER,
prtExPVc4TxGain Integer32,
prtExPVc4RxGain Integer32,
prtExPVc4MaxRate INTEGER,
prtExPVc4Tc INTEGER,
prtExPVc4Oos INTEGER,
prtExPVc4EchoCanceler INTEGER,
prtExPVc4VarDelay Integer32,
prtExPVc4CongLevel Integer32,
prtExPVc4Wire INTEGER,
prtExPVc4ExtensionType INTEGER,
prtExPVc4ExtensionNumber DisplayString,
prtExPVc4OutPulsing INTEGER,
prtExPVc4HuntGroupMb INTEGER,
prtExPVc4HuntGroupIdx Integer32,
prtExPVc4AutoFaxMode INTEGER,
prtExPVc4FaxRate INTEGER,
prtExPVc4SeizeAck INTEGER,
prtExPVc4SignalingProtocol INTEGER,
prtExPVc4DelayStart Integer32,
prtExPVc4WinkMinDuration Integer32,
prtExPVc4WinkMaxDuration Integer32,
prtExPVc4GenerateTone INTEGER,
prtExPVc4CodingLaw INTEGER,
prtExPVc4GenerateRingBack INTEGER,
prtExPVc4ChannelId Integer32,
prtExPVc4PortConnection INTEGER,
prtExPVc4CoderAndRate INTEGER,
prtExPVc4DestinationNum DisplayString,
prtExPVc4DtmfRelay INTEGER,
prtExPVc4DiscOnSilence Integer32,
prtExPVc4DynamicJitter INTEGER,
prtExPVc4EandMType INTEGER,
prtExPVc4Rate Integer32,
prtExPVc4FrameSize Integer32,
prtExPVc4MultiplexInterval Integer32,
prtExPVc4TransportProtocol INTEGER,
prtExPVc4MultiFreqRelay INTEGER,
prtExPVc4MinPulseWidth Integer32,
prtExPVc4MinPowerLevel Integer32,
prtExPVc4SuperTandem INTEGER,
prtExPVc4DestIp IpAddress,
prtExPVc4DestBundle Integer32,
prtExPVc4SrcIpAddress IpAddress,
prtExPVc4SrcIpMask IpAddress,
prtExPVc4DefaultGateway IpAddress,
prtExPVc4SigPacketInterval Unsigned32
}
prtExPVc4CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExPVc4CnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExPVc4SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted."
::= {prtExPVc4CnfgEntry 2}
prtExPVc4PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
exPrt3 (3),
exPrt4 (4),
inPrt1(101),
inPrt2(102),
inPrt3(103),
inPrt4(104),
inPrt5(105),
inPrt6(106),
inPrt7(107),
inPrt8(108)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the port number in the selected card
(slot)."
::= {prtExPVc4CnfgEntry 3}
prtExPVc4PrtType OBJECT-TYPE
SYNTAX INTEGER
{
eAndM (1),
fxo (2),
fxs (3),
internal(4),
s0 (5),
u (6),
sQsig (7),
uQsig (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the type of the selected port.
In Mx 30/300 phase 4: s0 & u are for Voice over ISDN.
In MX 30/300 phase 5: sQsig & uQsig are used for Voice over ISDN with Qsig option.
In MX MVC4 voice cards, each pair of ports 1-2, 3-4 may have a different type:
E&M, FXO, FXS.
In MVC4 compressed voice cards ports 1..4 have the same interface for all ports.
In MVC8 compressed voice cards each group of ports 1..4, 5..8 may have
a different type: E&M, FXO, FXS."
::= {prtExPVc4CnfgEntry 4}
prtExPVc4Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithms."
::= {prtExPVc4CnfgEntry 5}
prtExPVc4IfType OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
eAndM4wires (2),
eAndM2wires (3),
fxoGnd (4),
fxoLoop (5),
fxsGnd (6),
fxsLoop (7),
e1Framer (8),
e1Slave (9),
t1Framer (10),
t1Slave (11)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the interface type of the port.
eAndM4wires and eAndM2wires - are valid only for E&M
port type
eAndM4wires - means 2/4 wires
fxoGnd and fxoLoop - are valid only for FXO port type
fxsGnd and fxsLoop - are valid only for FXS port type
e1Framer, e1Slave, t1Framer, t1Slave - are applicable for the mvc4Pbx
cards only."
::= {prtExPVc4CnfgEntry 6}
prtExPVc4TxGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transmission gain in dB."
::= {prtExPVc4CnfgEntry 7}
prtExPVc4RxGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reception gain in dBm."
::= {prtExPVc4CnfgEntry 8}
prtExPVc4MaxRate OBJECT-TYPE
SYNTAX INTEGER
{
notConnected (1),
r4800bps (2),
r7200bps (3),
r9600bps (4),
notApplicatble (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Voice rate."
::= {prtExPVc4CnfgEntry 9}
prtExPVc4Tc OBJECT-TYPE
SYNTAX INTEGER
{
t1sec (1),
t2sec (2),
t3sec (3),
t4sec (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time interval for CIR control, in seconds. The value will
be the same for all cards' ports."
::= {prtExPVc4CnfgEntry 10}
prtExPVc4Oos OBJECT-TYPE
SYNTAX INTEGER
{
notSupported (2),
forcedIdle (3),
forcedBusy (4),
busyIdle (5),
idleBusy (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Handling type, when connection is lost."
::= {prtExPVc4CnfgEntry 11}
prtExPVc4EchoCanceler OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Echo canceler activation."
::= {prtExPVc4CnfgEntry 12}
prtExPVc4VarDelay OBJECT-TYPE
SYNTAX Integer32 (0..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum variant delay of the FR network, in msec."
::= {prtExPVc4CnfgEntry 13}
prtExPVc4CongLevel OBJECT-TYPE
SYNTAX Integer32 (0..70)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the level of delayed data in
precents of total available dynamic memory,
for which the port will start to operate as congested.
The resolution of the parameter is 5%."
::= {prtExPVc4CnfgEntry 14}
prtExPVc4Wire OBJECT-TYPE
SYNTAX INTEGER
{
w2wire (1),
w4wire (2),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the wiring of the E&M port.
It is applicable only for E&M card type."
::= {prtExPVc4CnfgEntry 15}
prtExPVc4ExtensionType OBJECT-TYPE
SYNTAX INTEGER
{ notApplicable(1),
forceConnect(2),
voiceSwitching(3),
transparent(4),
transparentPlus(5),
ipForceConnect(6),
permanentDial (7),
autoAccept (8) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the type of extension relevant for this port.
ipForceConnect (6) is used for automatic connection or automatic
dialing when the phone is off hook (hot line).
permanentDial (7) means that the call is established upon power up.
The hook may be on or off.
Permanent Dialing can be used when there is no signaling.
autoAccept (8) means that the called party in the Permanent Dialing
will accept the call from the remote side automatically
upon on or off hook."
::= {prtExPVc4CnfgEntry 16}
prtExPVc4ExtensionNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the extension number of this port.
This field is relevant only when the extension
type is voice switching and is read only if the
port is member of a hunt group."
::= {prtExPVc4CnfgEntry 17}
prtExPVc4OutPulsing OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1), no(2), yes(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field indicates whether to outpulse the received
digits. It is notApplicable(1) when the extension type
is forceConnect(2)."
::= {prtExPVc4CnfgEntry 18}
prtExPVc4HuntGroupMb OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1), no(2), yes(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if this port belongs to
an hunt group."
::= {prtExPVc4CnfgEntry 19}
prtExPVc4HuntGroupIdx OBJECT-TYPE
SYNTAX Integer32(0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If it belongs to an hunt group, this fields
indicates the index of the relevant hunt group.
0 = notApplicable "
::= {prtExPVc4CnfgEntry 20}
prtExPVc4AutoFaxMode OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1), no(2), yes(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if the system will switch automatically to
FAX mode when detecting FAX activity.
Default=Yes."
::= {prtExPVc4CnfgEntry 21}
prtExPVc4FaxRate OBJECT-TYPE
SYNTAX INTEGER
{
notConnected (1),
r4800bps (2),
r7200bps (3),
r9600bps (4),
r12000bps (5),
r14400bps (6),
r2400bps (7),
vbdFax (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"FAX initial rate.
Default=9600 bps."
::= {prtExPVc4CnfgEntry 22}
prtExPVc4SeizeAck OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter shows whether the device will acknowledge
a seize signal (On/Off Hook).
When the value is set to yes(3) & the device receives an on/off hook signal
it will transmit back an on/off hook signal.
When the value is set to no(2) & the device receives an on/off hook signal
it will NOT transmit back an on/off hook signal.
Example:
If Seize Ack Parameter = YES, when the MVC.4 receives a seize signal (Off Hook)
from the PBX it will send an Off Hook to the PBX.
The Seize Parameter is relevant for all the following cards:
MVC-4
MVC-4/E1-Framer
MVC-4/T1-DSU-Framer
MVC-4/T1-CSU-Framer
MVC-4/E1-SLAVE
MVC-4/T1-SLAVE
Default values:
Analog FXS - No (value can't be changed).
Analog FXO - Yes (value can't be changed).
Analog E&M - No (values NO/YES).
Digital E1/T1 Framer & Slave - No."
::= {prtExPVc4CnfgEntry 23}
prtExPVc4SignalingProtocol OBJECT-TYPE
SYNTAX INTEGER
{
delayStart (2),
immediateStart (3),
winkStart (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The signaling protocol that will be used between the PABX & the voice port.
Delay Start Protocol: the line is seized by sending an Off hook signal
and after a delay, if the called party is available (On hook)
DTMF (Dual Tone Multi Frequency) digits are sent towards the called party.
Immediate Start Protocol: the line is seized by sending an Off Hook signal
and immediately DTMF digits are sent towards the called party.
Wink start protocol: the line is seized by sending an Off Hook signal
and then the called party sends a short Off Hook wink signal.
Now the calling party starts sending DTMF digits."
::= {prtExPVc4CnfgEntry 24}
prtExPVc4DelayStart OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is used only for Delay Protocol.
This is the time that the calling party will wait after sending an Off hook
signal and before sending DTMF digits to the called party.
The delay values are 100..5000 msec in intervals of 100 msec."
::= {prtExPVc4CnfgEntry 25}
prtExPVc4WinkMinDuration OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is used only for Wink Protocol.
Min Duration of the Wink Signal (off hook duration from the called party).
Legal values: 40..400 msec in intervals of 10 msec."
::= {prtExPVc4CnfgEntry 26}
prtExPVc4WinkMaxDuration OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is used only for Wink Protocol.
Max Duration of the Wink Signal (off hook duration from the called party).
Legal values: 40..400 msec in intervals of 10 msec."
::= {prtExPVc4CnfgEntry 27}
prtExPVc4GenerateTone OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates whether the device (MX or MPH) should generate
dial tones for the channel.
If the value is yes (3), it generates dial tones.
If the value is no (2), the connected equipment will generate dial tones.
For example for some ISDN sets the dial tone is generated by the
phone itself while for others sets it is generated by the MX."
::= {prtExPVc4CnfgEntry 28}
prtExPVc4CodingLaw OBJECT-TYPE
SYNTAX INTEGER
{
aLAW (1),
uLAW (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Method/Law for decoding/encoding the voice
information.
aLaw(1) is the standard Law for E1 links.
uLaw(2) is the standard Law for T1 links.
This object is equal for all the ports in the specific module because
of HW limitations"
::= {prtExPVc4CnfgEntry 29}
prtExPVc4GenerateRingBack OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines whether the Ring Back tone is generated locally or from the
remote end.
The default is - NO (Meaning coming from the remote end).
Yes means that the Ring Back Tone is generated locally.
Applicable only for Force Connect."
::= {prtExPVc4CnfgEntry 30}
prtExPVc4ChannelId OBJECT-TYPE
SYNTAX Integer32 (0..256)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Channel Identifier.
According to FRF11 each voice port that works as force connect should add a
CH Id after the DLCI in the frame header.
Default : 1
Applicable only for Force Connect.
Not Applicable value will be 0."
::= {prtExPVc4CnfgEntry 31}
prtExPVc4PortConnection OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
line (2),
trunk (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port connection determines whether the port is connected to a PABX (Trunk) or to
Telephone set (Line) .
It determines whether to send certain messages to the port or not.
If the type is LINE then the port generates a
ring back tone , if TRUNK it doesn't (The PBX does it)."
::= {prtExPVc4CnfgEntry 32}
prtExPVc4CoderAndRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
g7231r6300BPS (2),
g7231r5300BPS (3),
g729A8KBPS (4),
g711aLAW (5),
g711uLAW (6),
g726r16KBPS (7),
g726r24KBPS (8),
g726r32KBPS (9),
g726r40KBPS (10),
g727r16KBPS (11),
g727r24r16KBPS (12),
g727r24KBPS (13),
g727r16r32KBPS (14),
g727r32r24KBPS (15),
g727r32KBPS (16),
g727r40r16KBPS (17),
g727r40r24KBPS (18),
g727r40r32KBPS (19),
transparent (20),
netcoder6400BPS (21),
netcoder7200BPS (22),
netcoder8KBPS (23),
netcoder8800BPS (24),
netcoder9600BPS (25),
lowBitRateR2660BPS (26),
amr4750BPS (27), -- Adaptive Multirate Coders of GSM
amr5150BPS (28),
amr5900BPS (29),
amr6700BPS (30),
amr7400BPS (31),
amr7950BPS (32),
amr10200BPS (33),
amr12200BPS (34)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Coder and Rate for the Voice Compression.
In MPH: Relevant for MVC-8 card only."
::= {prtExPVc4CnfgEntry 33}
prtExPVc4DestinationNum OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination phone number: 0 to 22 digits.
Applicable for Auto Dial - ipForceConnect(6), Permanent Dial and
Auto Accept Extension Types.
Default: Null String"
::= {prtExPVc4CnfgEntry 34}
prtExPVc4DtmfRelay OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When DTMF RELAY is disabled, the DTMF digits (dialed by the user)
are transmitted as compressed voice and in the remote unit are decompressed.
When DTMF RELAY is enabled, the DTMF digits are detected at the near side and not
transmitted as voice. Instead, only an indication of what digits were
dialed are transmitted and in the far end the tone is regenerated."
::= {prtExPVc4CnfgEntry 35}
prtExPVc4DiscOnSilence OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"No. of silenced seconds after which the call will be disconected.
A value of 0 means that there will be no disconnect when there is silence.
Possible values: 0 - 900 sec."
::= {prtExPVc4CnfgEntry 36}
prtExPVc4DynamicJitter OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MVC8 uses two mechanisms to overcome the network delay.
The first one is a static jitter buffer which holds a constant buffer of up
to 300 Msec and can be controled by the JITTER parameter (prtExPVc4VarDelay).
The second one is the dynamic jitter which calculates, in real time,
the network delay and handles a jitter buffer dynamically.
The dynamic mechanism that is implemented in MVC8, was intended to overcome
network delay yet when the network bursts, the MVC8 dynamic mechanism is
not able to overcome the delay.
Therefore it is better not to use the dynamic jitter
(DISABLE - should be the default) where bursts may occur often."
::= {prtExPVc4CnfgEntry 37}
prtExPVc4EandMType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
type1 (2),
type2 (3),
type3 (4),
ssdc5 (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the signaling type on the E&M analog side.
The analog signaling includes voltage, no. of pins and other parameters."
::= {prtExPVc4CnfgEntry 38}
prtExPVc4Rate OBJECT-TYPE
SYNTAX Integer32 (0..31)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the Rate of the port in TS units. It is used by VF-30 card family.
0 = NA = port is not intended to be connected; therefore, no Rate."
::= {prtExPVc4CnfgEntry 39}
prtExPVc4FrameSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the maximum size in Bytes of the multiplexed frame.
In some cases this must be limited to avoid IP fragmentation,
which makes the multiplexing useless, and can also decrease
the damage in case of frame loss.
Valid range: 100..1461.
notApplicable=0."
::= {prtExPVc4CnfgEntry 40}
prtExPVc4MultiplexInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the maximum amout of time (msec.) between multiplexed frames
that are sent.
For Vmux-400/420 devices:
It defines the Payload Packetizing Interval.
Valid values: 10-90 msec.
notApplicable=0."
::= {prtExPVc4CnfgEntry 41}
prtExPVc4TransportProtocol OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
ptp (2),
aal2oMpls (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transport Protocol.
ptp = point to point.
aal2oMpls = AAL2 over MPLS."
::= {prtExPVc4CnfgEntry 42}
prtExPVc4MultiFreqRelay OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables/disables Multi Frequency Signaling Detection."
::= {prtExPVc4CnfgEntry 43}
prtExPVc4MinPulseWidth OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the minimum Pulse Width in msec.
Valid values: 45-100 msec.
notApplicable=0."
::= {prtExPVc4CnfgEntry 44}
prtExPVc4MinPowerLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the minimum Power Level in dBm.
Valid values: -1..-35 dBm."
::= {prtExPVc4CnfgEntry 45}
prtExPVc4SuperTandem OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Super Tandem feature provides end to end compression
over multiple hops, solving the double compression problem
detected in Voice compressing systems.
The Super Tandem, when enabled, allows transmission of
compressed voice between a few devices and eliminates the
need to decompress an recompress it over each voice card and
PBX, thus improving voice quality and reducing delay."
::= {prtExPVc4CnfgEntry 46}
prtExPVc4DestIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the destination IP Address."
::= {prtExPVc4CnfgEntry 47}
prtExPVc4DestBundle OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the destination Bundle at the
far-end device."
::= {prtExPVc4CnfgEntry 48}
prtExPVc4SrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Source IP Address."
::= {prtExPVc4CnfgEntry 49}
prtExPVc4SrcIpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Source IP Mask."
::= {prtExPVc4CnfgEntry 50}
prtExPVc4DefaultGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Default Gateway for this interface."
::= {prtExPVc4CnfgEntry 51}
prtExPVc4SigPacketInterval OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the Signaling Packetizing Interval,
which is the maximum time interval, measured in msec (milliseconds),
between multiplexed signaling frames."
::= { prtExPVc4CnfgEntry 52 }
--
-- Packet VC4 card
-- External port Dlci table
--
prtExPVc4DlciTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExPVc4DlciEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
at the TmpCnfg entry."
::= {prtPVc4Cnfg 2}
prtExPVc4DlciEntry OBJECT-TYPE
SYNTAX PrtExPVc4DlciEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExPVc4DlciCnfgIdx, prtExPVc4DlciSltIdx, prtExPVc4DlciPrtIdx}
::= { prtExPVc4DlciTable 1}
PrtExPVc4DlciEntry ::=
SEQUENCE {
prtExPVc4DlciCnfgIdx Integer32,
prtExPVc4DlciSltIdx INTEGER,
prtExPVc4DlciPrtIdx INTEGER,
prtExPVc4DlciValid INTEGER,
prtExPVc4DlciIConSlt INTEGER,
prtExPVc4DlciIConPrt INTEGER,
prtExPVc4DlciIConDlci Integer32,
prtExPVc4DlciTxBc INTEGER,
prtExPVc4DlciTxBe INTEGER,
prtExPVc4DlciRxBc INTEGER,
prtExPVc4DlciRxBe INTEGER,
prtExPVc4DlciPriority Integer32,
prtExPVc4DlciStatus INTEGER
}
prtExPVc4DlciCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtExPVc4DlciEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExPVc4DlciSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= { prtExPVc4DlciEntry 2}
prtExPVc4DlciPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique internal port number.
VC4 cards have four external ports."
::= { prtExPVc4DlciEntry 3}
prtExPVc4DlciValid OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the attributes in this
entry are valid or not. The user can add/delete pvc (dlci
to dlci connection) by modifing this object"
::= { prtExPVc4DlciEntry 4}
prtExPVc4DlciIConSlt OBJECT-TYPE
SYNTAX INTEGER
{
noConnect (2),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position In the Mux
(Agent) where the dlci is routed to.
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= { prtExPVc4DlciEntry 5}
prtExPVc4DlciIConPrt OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
noConnect (100),
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103) ,
inPrt4 (104) ,
inPrt5 (105) ,
inPrt6 (106) ,
inPrt7 (107) ,
inPrt8 (108) ,
inPrt9 (109) ,
inPrt10 (110) ,
inPrt11 (111) ,
inPrt12 (112)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique port id which the dlci is
routed to."
::= { prtExPVc4DlciEntry 6}
prtExPVc4DlciIConDlci OBJECT-TYPE
SYNTAX Integer32 (1..991)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique internal connection dlci
number, the dlci is routed to."
::= { prtExPVc4DlciEntry 7}
prtExPVc4DlciTxBc OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
txBc9600bps (3),
txBc14400bps (4),
txBc19200bps (5),
txBc28800bps (6),
txBc32000bps (7),
txBc38400bps (8),
txBc48000bps (9),
txBc56000bps (10),
txBc57600bps (11),
txBc64Kbps (12),
txBc128Kbps (13),
txBc192Kbps (14),
txBc256Kbps (15),
txBc320Kbps (16),
txBc384Kbps (17),
txBc448Kbps (18),
txBc512Kbps (19),
txBc768Kbps (20),
txBc1024Kbps (21),
--
--KM30 ; KM300 additional rates
--
txBc16000bps (25),
txBc112Kbps (26)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Tx committed bandwidth on
the user transmit line (or at the port receive line)."
::= { prtExPVc4DlciEntry 8}
prtExPVc4DlciTxBe OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
txBe9600bps (3),
txBe14400bps (4),
txBe19200bps (5),
txBe28800bps (6),
txBe32000bps (7),
txBe38400bps (8),
txBe48000bps (9),
txBe56000bps (10),
txBe57600bps (11),
txBe64Kbps (12),
txBe128Kbps (13),
txBe192Kbps (14),
txBe256Kbps (15),
txBe320Kbps (16),
txBe384Kbps (17),
txBe448Kbps (18),
txBe512Kbps (19),
txBe768Kbps (20),
txBe1024Kbps (21),
--
--KM30 ; KM300 additional rates
--
txBc16000bps (25),
txBc112Kbps (26)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Tx excess bandwidth on the
user transmit line (or at the port receive line)."
::= { prtExPVc4DlciEntry 9}
prtExPVc4DlciRxBc OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
rxBc9600bps (3),
rxBc14400bps (4),
rxBc19200bps (5),
rxBc28800bps (6),
rxBc32000bps (7),
rxBc38400bps (8),
rxBc48000bps (9),
rxBc56000bps (10),
rxBc57600bps (11),
rxBc64Kbps (12),
rxBc128Kbps (13),
rxBc192Kbps (14),
rxBc256Kbps (15),
rxBc320Kbps (16),
rxBc384Kbps (17),
rxBc448Kbps (18),
rxBc512Kbps (19),
rxBc768Kbps (20),
rxBc1024Kbps (21),
--
--KM30 ; KM300 additional rates
--
rxBc16000bps (25),
rxBc112Kbps (26)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Rx committed bandwidth on the
user receive line (or at the port transmit line)."
::= { prtExPVc4DlciEntry 10}
prtExPVc4DlciRxBe OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
rxBe9600bps (3),
rxBe14400bps (4),
rxBe19200bps (5),
rxBe28800bps (6),
rxBe32000bps (7),
rxBe38400bps (8),
rxBe48000bps (9),
rxBe56000bps (10),
rxBe57600bps (11),
rxBe64Kbps (12),
rxBe128Kbps (13),
rxBe192Kbps (14),
rxBe256Kbps (15),
rxBe320Kbps (16),
rxBe384Kbps (17),
rxBe448Kbps (18),
rxBe512Kbps (19),
rxBe768Kbps (20),
rxBe1024Kbps (21),
--
--KM30 ; KM300 additional rates
--
rxBc16000bps (25),
rxBc112Kbps (26)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Rx excess bandwidth on the
user receive line (or at the port transmit line)."
::= { prtExPVc4DlciEntry 11}
prtExPVc4DlciPriority OBJECT-TYPE
SYNTAX Integer32 (6..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique priority of the pvc.
6 is the lowest priority and 8 is the highest priority."
::= { prtExPVc4DlciEntry 12}
prtExPVc4DlciStatus OBJECT-TYPE
SYNTAX INTEGER
{
disconnected (1),
connected (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of the pvc. The status is
disconnected(1) when one of the sides is programmed as not
connected"
::= { prtExPVc4DlciEntry 13}
--
-- Megaplex ?000/?004 LS-6 TDM I/O family card include:
-- Ls6, Ls6V1/E, Ls6V1/O, Ls6V1/S, Ls6V2/E, Ls6V2/O, Ls6V2/S,
-- Ls6Vf/E, Ls6Vf/O, Ls6Vf/S
--
--prtExLs6CnfgTable OBJECT IDENTIFIER ::= {prtLs6Cnfg 1}
--prtExLs6VCnfgTable OBJECT IDENTIFIER ::= {prtLs6Cnfg 2}
--prtInLs6CnfgTable OBJECT IDENTIFIER ::= {prtLs6Cnfg 3}
--prtExLs6CnfgTable defines the parameters of the
-- LS-6 cards family external Data ports (1-6) ; LS-12 (1-12)
prtExLs6CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExLs6CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtLs6Cnfg 1}
prtExLs6CnfgEntry OBJECT-TYPE
SYNTAX PrtExLs6CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExLs6CnfgIdx, prtExLs6SltIdx, prtExLs6PrtIdx }
::= {prtExLs6CnfgTable 1}
PrtExLs6CnfgEntry ::=
SEQUENCE {
prtExLs6CnfgIdx Integer32,
prtExLs6SltIdx INTEGER,
prtExLs6PrtIdx INTEGER,
prtExLs6Connect INTEGER,
prtExLs6Protocol INTEGER,
prtExLs6Rate INTEGER,
prtExLs6ClkMode INTEGER,
prtExLs6CtrlSignal INTEGER,
prtExLs6DataBits INTEGER,
prtExLs6Cts INTEGER,
prtExLs6LinkToInternal INTEGER
}
prtExLs6CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExLs6CnfgEntry 1}
prtExLs6SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtExLs6CnfgEntry 2}
prtExLs6PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
exPrt11 (11) ,
exPrt12 (12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port index."
::= {prtExLs6CnfgEntry 3}
prtExLs6Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithms."
::= {prtExLs6CnfgEntry 4}
prtExLs6Protocol OBJECT-TYPE
SYNTAX INTEGER
{
sync (2),
async (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the protocol.
async - can be selected only for ports 1-2."
::= {prtExLs6CnfgEntry 5}
prtExLs6Rate OBJECT-TYPE
SYNTAX INTEGER
{
r300bps (2),
r600bps (3),
r1200bps (4),
r2400bps (5),
r4800bps (6),
r7200bps (7),
r8000bps (8),
r9600bps (9),
r14400bps (10),
r16000bps (11),
r19200bps (12),
r24000bps (13),
r28800bps (14),
r32000bps (15),
r38400bps (16),
r48000bps (17),
r56000bps (18),
r57600bps (19),
r64000bps (20)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port rates in bps.
g1 - contains the values : (2)-(6),(9),(12),(16)
g2 - contains the values : (7),(10),(14),(19)
g3 - contains the values : (8),(11),(13),(15),(17),(18),(20);
it is not applicable when using Async protocol.
Rates of pair ports (1-2, 3-4, 5-6) must be from the same
group."
::= {prtExLs6CnfgEntry 6}
prtExLs6ClkMode OBJECT-TYPE
SYNTAX INTEGER
{
dce (1),
extDce (2),
dte1 (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique port operation clock mode.
It is applicable for Sync protocol only ."
::= {prtExLs6CnfgEntry 7}
prtExLs6CtrlSignal OBJECT-TYPE
SYNTAX INTEGER
{
local (2),
rts (3),
dtrAndRts (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control Signal."
::= {prtExLs6CnfgEntry 8}
prtExLs6DataBits OBJECT-TYPE
SYNTAX INTEGER
{
d6bits (1),
d7bits (2),
d8bits (3),
d9bits (4),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data Bits.
This object is applicable for Async protocol only."
::= {prtExLs6CnfgEntry 9}
prtExLs6Cts OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
on (2),
rts (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the CTS control line
operation mode."
::= {prtExLs6CnfgEntry 10}
prtExLs6LinkToInternal OBJECT-TYPE
SYNTAX INTEGER
{
inPrt1 (101) ,
inPrt2 (102) ,
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates which internal port of the card,
the external port is linked to."
::= {prtExLs6CnfgEntry 11}
--prtExLs6VCnfgTable defines the parameters of the
-- LS-6 cards family external Voice & FAX ports (7-8)
prtExLs6VCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExLs6VCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtLs6Cnfg 2}
prtExLs6VCnfgEntry OBJECT-TYPE
SYNTAX PrtExLs6VCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExLs6VCnfgIdx, prtExLs6VSltIdx, prtExLs6VPrtIdx }
::= {prtExLs6VCnfgTable 1}
PrtExLs6VCnfgEntry ::=
SEQUENCE {
prtExLs6VCnfgIdx Integer32,
prtExLs6VSltIdx INTEGER,
prtExLs6VPrtIdx INTEGER,
prtExLs6VConnect INTEGER,
prtExLs6VRate INTEGER,
prtExLs6VEchoCanceler INTEGER,
prtExLs6VIfType INTEGER,
prtExLs6VTxGain Integer32,
prtExLs6VRxGain Integer32,
prtExLs6VOos INTEGER
}
prtExLs6VCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExLs6VCnfgEntry 1}
prtExLs6VSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtExLs6VCnfgEntry 2}
prtExLs6VPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt7 (7) ,
exPrt8 (8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port, within the card."
::= {prtExLs6VCnfgEntry 3}
prtExLs6VConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithms."
::= {prtExLs6VCnfgEntry 4}
prtExLs6VRate OBJECT-TYPE
SYNTAX INTEGER
{
r6400bps (2),
r7200bps (3),
r8000bps (4),
r9600bps (5),
r16000bps (6),
r24000bps (7),
r32000bps (8),
r64000bps (9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Rate (bps) used for FAX transmission and Voice coding."
::= {prtExLs6VCnfgEntry 5}
prtExLs6VEchoCanceler OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Echo canceler activation."
::= {prtExLs6VCnfgEntry 6}
prtExLs6VIfType OBJECT-TYPE
SYNTAX INTEGER
{
w2wire (1),
w4wire (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the interface type of the port.
w4wire - is applicable only for E&M port type."
::= {prtExLs6VCnfgEntry 7}
prtExLs6VTxGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transmit gain in dBm.
E&M - values range: -17 .. 8
FXO - values range: -16 .. 4
FXS - values range: -13 .. 8 "
::= {prtExLs6VCnfgEntry 8}
prtExLs6VRxGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Receive gain in dBm.
E&M - values range: -17 .. 2
FXO - values range: -17 .. -1
FXS - values range: -17 .. 2 "
::= {prtExLs6VCnfgEntry 9}
prtExLs6VOos OBJECT-TYPE
SYNTAX INTEGER
{
forcedIdle (1),
forcedBusy (2),
busyIdle (3),
idleBusy (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Out of Service signaling mode."
::= {prtExLs6VCnfgEntry 10}
-- Ls6 and Ls12 Internal composite channel parameters
--
prtInLs6CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInLs6CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtLs6Cnfg 3}
prtInLs6CnfgEntry OBJECT-TYPE
SYNTAX PrtInLs6CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtInLs6CnfgIdx, prtInLs6SltIdx, prtInLs6PrtIdx }
::= {prtInLs6CnfgTable 1}
PrtInLs6CnfgEntry ::=
SEQUENCE {
prtInLs6CnfgIdx Integer32,
prtInLs6SltIdx INTEGER,
prtInLs6PrtIdx INTEGER,
prtInLs6Connect INTEGER,
prtInLs6TandemMode INTEGER,
prtInLs6Rate INTEGER,
prtInLs6RemoteType INTEGER,
prtInLs6LinkTo INTEGER
}
prtInLs6CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtInLs6CnfgEntry 1}
prtInLs6SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtInLs6CnfgEntry 2}
prtInLs6PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
inPrt1 (101),
inPrt2 (102)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique internal port index."
::= {prtInLs6CnfgEntry 3}
prtInLs6Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered in
any of the mux algorithms. It also affects all the module
considerations because the module has only one Internal
interface which is the composite channel."
::= {prtInLs6CnfgEntry 4}
prtInLs6TandemMode OBJECT-TYPE
SYNTAX INTEGER
{
noTandem (1),
tandemMaster (2),
tandemSlave (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Tandem Mode.
tandemSlave - is valid only for an LS-6 card having on
the (current slot-1) an LS-6 card with 'tandemMaster' mode."
::= {prtInLs6CnfgEntry 5}
prtInLs6Rate OBJECT-TYPE
SYNTAX INTEGER
{
r32Kbps (1),
r56Kbps (2),
r64Kpbs (3),
r128Kbps (4),
r256Kbps (5),
r384Kbps (6),
r192Kbps (7),
r512Kbps (8),
r768Kbps (9),
r14400bps(10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Main Rate in Kbps."
::= {prtInLs6CnfgEntry 6}
prtInLs6RemoteType OBJECT-TYPE
SYNTAX INTEGER
{
ls6 (1),
km2kSlave (2),
km2kStandalone (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Remote Type.
notApplicable - when prtInLs6TandemMode=tandemSlave "
::= {prtInLs6CnfgEntry 7}
prtInLs6LinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"It indicates the slot of the main link card to which the
Ls6 card is mapped.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
notApplicable - when prtInLs6TandemMode=tandemSlave.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort. "
::= {prtInLs6CnfgEntry 8}
--
-- Megaplex?000/?004 VC-3 TDM I/O family port.
-- (VC3/E&M,VC3/FXO,VC3/FXS)
--
--
--prtExVc3CnfgTable defines the parameters of the
-- VC-3 and VF-3 cards family external ports
prtExVc3CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExVc3CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { prtVc3Cnfg 1}
prtExVc3CnfgEntry OBJECT-TYPE
SYNTAX PrtExVc3CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExVc3CnfgIdx, prtExVc3SltIdx, prtExVc3PrtIdx }
::= { prtExVc3CnfgTable 1}
PrtExVc3CnfgEntry ::=
SEQUENCE {
prtExVc3CnfgIdx Integer32,
prtExVc3SltIdx INTEGER,
prtExVc3PrtIdx INTEGER,
prtExVc3Connect INTEGER,
prtExVc3TransGain Integer32,
prtExVc3ReceiveGain Integer32,
prtExVc3Wire INTEGER,
prtExVc3Rate INTEGER,
prtExVc3EchoCanceler INTEGER
}
prtExVc3CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExVc3CnfgEntry 1}
prtExVc3SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtExVc3CnfgEntry 2}
prtExVc3PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port, within the card."
::= {prtExVc3CnfgEntry 3}
prtExVc3Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithms."
::= {prtExVc3CnfgEntry 4}
prtExVc3TransGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transmit gain in dBm."
::= {prtExVc3CnfgEntry 5}
prtExVc3ReceiveGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Receive gain in dBm."
::= {prtExVc3CnfgEntry 6}
prtExVc3Wire OBJECT-TYPE
SYNTAX INTEGER
{
w2wire (1),
w4wire (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is equal for all the ports in the specific
card because of HW limitations"
::= {prtExVc3CnfgEntry 7}
prtExVc3Rate OBJECT-TYPE
SYNTAX INTEGER
{
r9600bps (1),
r4800bps (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Rate in bps."
::= {prtExVc3CnfgEntry 8}
prtExVc3EchoCanceler OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Echo canceler activation. The value will be the same for
all the card's external ports."
::= {prtExVc3CnfgEntry 9}
--prtInVc3CnfgTable defines the parameters of the
-- VC-3 or VF-3 cards family internal ports
prtInVc3CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInVc3CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { prtVc3Cnfg 2}
prtInVc3CnfgEntry OBJECT-TYPE
SYNTAX PrtInVc3CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtInVc3CnfgIdx, prtInVc3SltIdx, prtInVc3PrtIdx }
::= { prtInVc3CnfgTable 1}
PrtInVc3CnfgEntry ::=
SEQUENCE {
prtInVc3CnfgIdx Integer32,
prtInVc3SltIdx INTEGER,
prtInVc3PrtIdx INTEGER,
prtInVc3Connect INTEGER,
prtInVc3Rate INTEGER,
prtInVc3Oos INTEGER,
prtInVc3LinkTo INTEGER
}
prtInVc3CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtInVc3CnfgEntry 1}
prtInVc3SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtInVc3CnfgEntry 2}
prtInVc3PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
inPrt1 (101)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port, within the card."
::= {prtInVc3CnfgEntry 3}
prtInVc3Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithms."
::= {prtInVc3CnfgEntry 4}
prtInVc3Rate OBJECT-TYPE
SYNTAX INTEGER
{
r32000bps (1),
r16000bps (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Rate in bps."
::= {prtInVc3CnfgEntry 5}
prtInVc3Oos OBJECT-TYPE
SYNTAX INTEGER
{
forcedIdle (1),
forcedBusy (2),
busyIdle (3),
idleBusy (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This object is equal for all the ports in the specific
card because of HW limitations"
::= {prtInVc3CnfgEntry 6}
prtInVc3LinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This attribute indicates the slot of the ML card to which
the VC card is mapped.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtInVc3CnfgEntry 7}
--
-- Megaplex?000/?004 VC-3 TDM I/O family port.
-- (VC-PBX, VC-PBX/T1,VC-PBX/E1)
--
--
--prtExVcPbxCnfgTable defines the parameters of the
-- VC-PBX or VF-PBX cards family external ports
prtExVcPbxCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExVcPbxCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { prtVcPbxCnfg 1}
prtExVcPbxCnfgEntry OBJECT-TYPE
SYNTAX PrtExVcPbxCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExVcPbxCnfgIdx, prtExVcPbxSltIdx, prtExVcPbxPrtIdx }
::= { prtExVcPbxCnfgTable 1}
PrtExVcPbxCnfgEntry ::=
SEQUENCE {
prtExVcPbxCnfgIdx Integer32,
prtExVcPbxSltIdx INTEGER,
prtExVcPbxPrtIdx INTEGER,
prtExVcPbxConnect INTEGER,
prtExVcPbxGroup INTEGER,
prtExVcPbxTransparent INTEGER,
prtExVcPbxTransSignalTs Integer32,
prtExVcPbxFrame INTEGER,
prtExVcPbxRestoreTime INTEGER,
prtExVcPbxLineCode INTEGER,
prtExVcPbxLineLength INTEGER,
prtExVcPbxLinkTo INTEGER,
prtExVcPbxSignalOper INTEGER,
prtExVcPbxIdleCode INTEGER
}
prtExVcPbxCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExVcPbxCnfgEntry 1}
prtExVcPbxSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtExVcPbxCnfgEntry 2}
prtExVcPbxPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port, within the card."
::= {prtExVcPbxCnfgEntry 3}
prtExVcPbxConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the port should be
considered in any of the mux algorithms."
::= {prtExVcPbxCnfgEntry 4}
prtExVcPbxGroup OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The group object links together several VC-PBX cards,
concerning compression of the same input T1/E1 link
time-slots.
When ports of different slots have the same group, they are
linked.
When ports have a different group, they are not linked.
For VC-PBX/T1 and E1 cards, this object is - their own
IO Slot.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtExVcPbxCnfgEntry 5}
prtExVcPbxTransparent OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the Transparent transfer
of Time-Slots is required or not.
Time-Slots transferred by Transparent, will not be
compressed.
no - applicable only for VC-PBX/T1 and VC-PBX/E1 cards
yes - applicable only for VC-PBX/T1 and VC-PBX/E1 cards
notApplicable - only for VC-PBX cards."
::= {prtExVcPbxCnfgEntry 6}
prtExVcPbxTransSignalTs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the ML Time-Slot dedicated to
the signaling of the PABX Transparent TSs.
None = 255.
When prtExVcPbxTransparent=no this object's value=None (255)
When prtExVcPbxTransparent=notApplicable, this object's
value=None (255).
When prtExVcPbxTransparent=yes:
- for VC-PBX/T1 ports, this object's valid values are 1..16
or None (255).
- for VC-PBX/E1 ports, this object's value will be 16 or None
(255)."
::= {prtExVcPbxCnfgEntry 7}
prtExVcPbxFrame OBJECT-TYPE
SYNTAX INTEGER
{
esfT1 (2), --> dsx1ESF
sfT1 (3), --> dsx1D4
g732nE1 (4), --> dsx1E1
g732nE1CRC (5), --> dsx1E1-CRC
g732sE1 (6), --> dsx1E1-MF
g732sE1CRC (7), --> dsx1E1-MF-CRC
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the frame parameter for T1/E1 interface.
The user should select only the parameters which are relevant
to the specific card:
T1 values for the VC-PBX/T1 card.
E1 values for the VC-PBX/E1 card.
notApplicable - for the VC-PBX card.
This parameter has the same values as dsx1LineType in T1/E1
MIB (RFC-1406). The parameters in dsx1LineType are:
other (1)
esfT1 dsx1ESF (2)
sfT1 dsx1D4 (3)
g732nE1 dsx1E1 (4)
g732nE1CRC dsx1E1-CRC (5)
g732sE1 dsx1E1-MF (6)
g732sE1CRC dsx1E1-MF-CRC (7) "
::= {prtExVcPbxCnfgEntry 8}
prtExVcPbxRestoreTime OBJECT-TYPE
SYNTAX INTEGER
{
restoreT1secFast (2),
restoreT10sec62411 (3),
ccittE1 (4),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time passing from the disappearance of the loss of
synchronization condition (red alarm) to the restoration of
normal service. The options 1secFast(2) and 10sec62411(3)
for E1 interfaces are proprietary implementation of the T1
standard to the E1 interface.
ccittE1 - is applicable only for VC-PBX/E1 card
notApplicable - is applicable for VC-PBX card"
::= {prtExVcPbxCnfgEntry 9}
prtExVcPbxLineCode OBJECT-TYPE
SYNTAX INTEGER
{
b7zsT1 (1), --> dsx1JBZS
b8zsT1 (2), --> dsx1B8ZS
transT1(3), --> dsx1AMI
hdb3E1 (4), --> dsx1HDB3
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the line code parameter used for T1/E1
interface.
The user should select only the parameters which are relevant
to the specific card:
T1 line code parameters for VC-PBX/T1
E1 line code parameters for VC-PBX/E1
notApplicable - for VC-PBX
This parameter has the same values as dsx1LineCoding in T1/E1
MIB (RFC-1406). The parameters in dsx1LineCoding are:
dsx1JBZS (1)
dsx1B8ZS (2)
dsx1HDB3 (3)
dsx1ZBTSI (4)
dsx1AMI (5)
other (6)"
::= {prtExVcPbxCnfgEntry 10}
prtExVcPbxLineLength OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
len0p133ft (2),
len134p266ft (3),
len267p399ft (4),
len400p533ft (5),
len534p655ft (6),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the line length parameter.
It is applicable only for the VC-PBX/T1 card.
notApplicable - for the VC-PBX and VC-PBX/E1 card.
lenXXXpXXXft = len-XXX-XXXft."
::= {prtExVcPbxCnfgEntry 11}
prtExVcPbxLinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates the slot of the ML card to which
the VC-PBX/T1, VC-PBX/E1 card Transparent TSs are mapped.
notApplicable - for VC-PBX card AND
for VC-PBX/T1, VC-PBX/E1 cards, when prtExVcPbxTransparent=no .
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtExVcPbxCnfgEntry 12}
prtExVcPbxSignalOper OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
normal (2),
bEqA (3),
inverseA (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Signaling Operation of the
VC-PBX/T1, VC-PBX/E1 external port.
notApplicable - for VC-PBX card
normal - all 4 signaling bits are transferred.
bEqA - copy the A bit into the B bit. Applicable only for
VC-PBX/T1."
::= {prtExVcPbxCnfgEntry 13}
prtExVcPbxIdleCode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
hff (2),
he4 (3),
hd5 (4),
h9e (5),
h98 (6),
h7f (7),
h7e (8),
h54 (9),
h1a (10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines the code for transmission in empty time slots.
notApplicable - for VC-PBX card ."
::= {prtExVcPbxCnfgEntry 14}
--prtIn1p6VcPbxCnfgTable defines the parameters of the
-- VC-PBX or VF-PBX cards family internal ports 1-6
prtIn1p6VcPbxCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtIn1p6VcPbxCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { prtVcPbxCnfg 2}
prtIn1p6VcPbxCnfgEntry OBJECT-TYPE
SYNTAX PrtIn1p6VcPbxCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtIn1p6VcPbxCnfgIdx, prtIn1p6VcPbxSltIdx, prtIn1p6VcPbxPrtIdx }
::= { prtIn1p6VcPbxCnfgTable 1}
PrtIn1p6VcPbxCnfgEntry ::=
SEQUENCE {
prtIn1p6VcPbxCnfgIdx Integer32,
prtIn1p6VcPbxSltIdx INTEGER,
prtIn1p6VcPbxPrtIdx INTEGER,
prtIn1p6VcPbxConnect INTEGER,
prtIn1p6VcPbxRate INTEGER,
prtIn1p6VcPbxEchoCanceler INTEGER,
prtIn1p6VcPbxPabxTs Integer32
}
prtIn1p6VcPbxCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtIn1p6VcPbxCnfgEntry 1}
prtIn1p6VcPbxSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtIn1p6VcPbxCnfgEntry 2}
prtIn1p6VcPbxPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103) ,
inPrt4 (104) ,
inPrt5 (105) ,
inPrt6 (106)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port, within the card."
::= {prtIn1p6VcPbxCnfgEntry 3}
prtIn1p6VcPbxConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the port should be
considered in any of the mux algorithms."
::= {prtIn1p6VcPbxCnfgEntry 4}
prtIn1p6VcPbxRate OBJECT-TYPE
SYNTAX INTEGER
{
r4800bps (1),
r6400bps (2),
r7200bps (3),
r8000bps (4),
r9600bps (5),
r12800bps (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the port Rate.
For Normal mode (prtIn7p8VcPbxMode=normal), only part of the values
are valid (constant rate).
For Server mode (prtIn7p8VcPbxMode=server), all values are
applicable (user can select the desired compression rate). "
::= {prtIn1p6VcPbxCnfgEntry 5}
prtIn1p6VcPbxEchoCanceler OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Echo canceler activation."
::= {prtIn1p6VcPbxCnfgEntry 6}
prtIn1p6VcPbxPabxTs OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines the PABX Time-Slot assigned to this
internal port.
For a T1 link, the valid values are: 1 .. 24.
For an E1 link, the valid values are: 1 .. 31.
This object is NOT applicable when prtIn1p6VcPbxConnect=no.
This object is applicable for all cards of VC-PBX family.
Default=the internal port index (1..6)."
::= {prtIn1p6VcPbxCnfgEntry 7}
--prtIn7p8VcPbxCnfgTable defines the parameters of the
-- VC-PBX or VF-PBX cards family internal ports 7-8
prtIn7p8VcPbxCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtIn7p8VcPbxCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { prtVcPbxCnfg 3}
prtIn7p8VcPbxCnfgEntry OBJECT-TYPE
SYNTAX PrtIn7p8VcPbxCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtIn7p8VcPbxCnfgIdx, prtIn7p8VcPbxSltIdx, prtIn7p8VcPbxPrtIdx }
::= { prtIn7p8VcPbxCnfgTable 1}
PrtIn7p8VcPbxCnfgEntry ::=
SEQUENCE {
prtIn7p8VcPbxCnfgIdx Integer32,
prtIn7p8VcPbxSltIdx INTEGER,
prtIn7p8VcPbxPrtIdx INTEGER,
prtIn7p8VcPbxConnect INTEGER,
prtIn7p8VcPbxMode INTEGER,
prtIn7p8VcPbxRate INTEGER,
prtIn7p8VcPbxSignalMode INTEGER,
prtIn7p8VcPbxOos INTEGER,
prtIn7p8VcPbxLinkTo INTEGER
}
prtIn7p8VcPbxCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtIn7p8VcPbxCnfgEntry 1}
prtIn7p8VcPbxSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtIn7p8VcPbxCnfgEntry 2}
prtIn7p8VcPbxPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
inPrt7 (107) ,
inPrt8 (108)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port, within the card."
::= {prtIn7p8VcPbxCnfgEntry 3}
prtIn7p8VcPbxConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the port should be
considered in any of the mux algorithms."
::= {prtIn7p8VcPbxCnfgEntry 4}
prtIn7p8VcPbxMode OBJECT-TYPE
SYNTAX INTEGER
{
normal (1),
server (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the working mode of the port:
- normal - the compressed voice will be sent to an MTML
card inside the Mux.
- server - the compressed voice will be sent to the Digital
Voice connector, as a service to an outside user."
::= {prtIn7p8VcPbxCnfgEntry 5}
prtIn7p8VcPbxRate OBJECT-TYPE
SYNTAX INTEGER
{
r32Kbps (1),
r16Kbps (2),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the port Main Rate.
For Server mode (prtIn7p8VcPbxMode=server), the value will
be notApplicable. "
::= {prtIn7p8VcPbxCnfgEntry 6}
prtIn7p8VcPbxSignalMode OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
aBit (2),
abcBit (3),
abcdBit (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Signal Mode.
For Server mode (prtIn7p8VcPbxMode=server), the only valid
values are:
- none
- aBit "
::= {prtIn7p8VcPbxCnfgEntry 7}
prtIn7p8VcPbxOos OBJECT-TYPE
SYNTAX INTEGER
{
forcedIdle (1),
forcedBusy (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Out of service Signaling mode."
::= {prtIn7p8VcPbxCnfgEntry 8}
prtIn7p8VcPbxLinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates the slot of the ML card to which
the VC card is mapped.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
For Server mode (prtIn7p8VcPbxMode=server), this object is
not applicable.
Both ports, 7 and 8 should be linked to the same Slot.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtIn7p8VcPbxCnfgEntry 9}
--prtExVcPbxTsTable defines PABX Time Slots assignment of the
-- VC-PBX E1/T1 cards, VF-PBX cards , VF-24/30/48/60 T1/E1 cards
-- and VFS cards
prtExVcPbxTsTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExVcPbxTsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the table objects is valid only
to the TmpCnfg entry."
::= { prtVcPbxCnfg 4}
prtExVcPbxTsEntry OBJECT-TYPE
SYNTAX PrtExVcPbxTsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExVcPbxTsCnfgIdx, prtExVcPbxTsSltIdx, prtExVcPbxTsPrtIdx, prtExVcPbxTsIdx }
::= { prtExVcPbxTsTable 1}
PrtExVcPbxTsEntry ::=
SEQUENCE {
prtExVcPbxTsCnfgIdx Integer32,
prtExVcPbxTsSltIdx INTEGER,
prtExVcPbxTsPrtIdx INTEGER,
prtExVcPbxTsIdx Integer32,
prtExVcPbxTsMode INTEGER,
prtExVcPbxTsIConSlot INTEGER,
prtExVcPbxTsIConPrt INTEGER,
prtExVcPbxTsIConTs Integer32,
prtExVcPbxTsRemPrt INTEGER,
prtExVcPbxTsRemTs Integer32,
prtExVcPbxTsRemConnID Unsigned32,
prtExVcPbxTsSourceSlot INTEGER,
prtExVcPbxTsSourcePrt Unsigned32
}
prtExVcPbxTsCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtExVcPbxTsEntry 1}
prtExVcPbxTsSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid"
::= { prtExVcPbxTsEntry 2}
prtExVcPbxTsPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
inPrt9 (109),
inPrt10 (110)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
VCPBX/E1, VCPBX/T1, VFPBX/E1, VFPBX/T1, VF-24/T1 and VF-30 cards
have only one external interface.
VF-48/T1 and VF-60/E1 cards have two external interfaces.
VFS cards have also internal ports."
::= { prtExVcPbxTsEntry 3}
prtExVcPbxTsIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique PABX time slot position.
The valid time slots are 1..24 for T1 cards and
1..31 for E1 cards."
::= { prtExVcPbxTsEntry 4}
prtExVcPbxTsMode OBJECT-TYPE
SYNTAX INTEGER
{
unused (1),
compressed (2), -- =compressedVoice
transparent (3),
compressedCcs(4),
mng (5),
ccs1 (11),
ccs2 (12),
ccs3 (13),
ccs4 (14),
ccs5 (15),
ccs6 (16),
ccs7 (17),
ccs8 (18),
ss7n1 (41),
ss7n2 (42),
ss7n3 (43),
ss7n4 (44),
ss7n5 (45),
ss7n6 (46),
ss7n7 (47),
ss7n8 (48)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the usage, process and way of the
specific PABX TS towards its destination:
unused - the TS is not used (no processing, no destination).
compressed - the TS is used, sent for compression to an
internal port (for VF-PBX cards: 1..6 for of either
the same card or a VF-PBX card of the same group).
For VF-24/30/48/60 - 'compressed' represents 'compressed Voice'
(to differentiate it from 'compressedCcs').
In this case, the TS is compressed by an internal port (1..8).
transparent - the TS is used; no processing. It is sent
directly for Bypass to a ML card the VF port/TS is linked to.
compressedCcs - supported only by VF-24/30/48/60 cards. The TS is used;
sent for compression to the CPU.
mng - the TS is used for Management (this option is used when the
external port is connected to another product that has to be
managed via this dedicated TS.
ccs1..ccs8 - supported only by VF-24/30/48/60 cards. Compressed TS that
comes from a bundle of V5.1 or V5.2 PBX.
ss7n1..ss7n8 - supported only by VF-24/30/48/60 cards. Compressed TS that
comes from a bundle of V5.1 or V5.2 PBX. ss7n1 can work versus
Vmux having prtExPh1MlTsType=ss7(6)."
::= { prtExVcPbxTsEntry 5}
prtExVcPbxTsIConSlot OBJECT-TYPE
SYNTAX INTEGER
{
noConnect (2),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For VF-PBX cards, the io1..io12 values are applicable only when
prtExVcPbxTsMode=compressed. Otherwise, its value should be
noConnect.
For VF-24/30/48/60 cards:
- when prtExVcPbxTsMode=transparent or voiceTransparent, the io1..io12 values are applicable,
indicating the ML Slot this TS is connected to.
- when prtExVcPbxTsMode=compressed or compressedCcs, the value
will be the same as prtExVcPbxTsSltIdx, since the compression is
done within the same card.
- for rest of the prtExVcPbxTsMode values, the value will be: noConnect.
This object indicates whether the specified compressed/transparent
time slot is connected/routed internally in the Agent and
to which card it is connected.
For VF-PBX card, the valid selectable slots are either the current one,
(prtExVcPbxTsSltIdx), or a slot containing a VF-PBX card.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtExVcPbxTsEntry 6}
prtExVcPbxTsIConPrt OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
exPrt3 (3),
exPrt4 (4),
exPrt5 (5),
exPrt6 (6),
exPrt7 (7),
exPrt8 (8),
noConnect (100),
inPrt1 (101),
inPrt2 (102),
inPrt3 (103),
inPrt4 (104),
inPrt5 (105),
inPrt6 (106),
inPrt7 (107),
inPrt8 (108)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the port to which this TS is connected.
For VF-PBX cards, only inPrt1..inPrt6 ports are valid.
For VF-24/30/48/60 cards:
- for prtExVcPbxTsMode=transparent or voiceTransparent, the valid ports are
ML ports (exPrt1.. exPrt8, inPrt1.. inPrt8)
- for prtExVcPbxTsMode=compressed or compressedCcs, the valid
ports are internal ports of the same card (inPrt1..inPrt8)
noConnect - when prtExVcPbxTsIConSlot=noConnect."
::= {prtExVcPbxTsEntry 7}
prtExVcPbxTsIConTs OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the ML TS to which this TS is connected.
This object is not applicable for VF-PBX cards.
For VF-24/30/48/60 cards it is applicable only when
prtExVcPbxTsMode=transparent or voiceTransparent.
The valid time slots are 1..24 for ML T1 cards and 1..31 for ML E1 cards.
notApplicable - 255. "
::= { prtExVcPbxTsEntry 8}
prtExVcPbxTsRemPrt OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
noConnect (100)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the end-point port on the Remote unit.
VF-24/T1 and VF-30/E1 cards have one external interface.
VF-48/T1 and VF-60/E1 cards have two external interfaces.
noConnect - when prtExVcPbxTsMode=unused, transparent, voiceTransparent or mng."
::= { prtExVcPbxTsEntry 9}
prtExVcPbxTsRemTs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the end-point TS on the Remote unit.
The valid time slots are 1..24 for T1 ports and 1..31 for E1 ports.
notApplicable - 255."
::= { prtExVcPbxTsEntry 10}
prtExVcPbxTsRemConnID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Connection ID with the Remote unit.
notApplicable = 0."
::= { prtExVcPbxTsEntry 11}
prtExVcPbxTsSourceSlot OBJECT-TYPE
SYNTAX INTEGER
{
noConnect (2),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For VFS cards. These cards offer Compresed Voice Services for
Analog Voice ports of the MP.
This object indicates the Source Slot of the Analog Voice port we want
to compress.
io1..io12 values are applicable only when prtExVcPbxTsMode=compressed(voice).
Otherwise, its value should be noConnect.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtExVcPbxTsEntry 12}
prtExVcPbxTsSourcePrt OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For VFS cards. These cards offer Compresed Voice Services for
Analog Voice ports of the MP.
This object indicates the Source Port within the Slot of the Analog Voice Card,
we want to compress.
exPrt1 - exPrt16 = 1 - 16
noConnect=100 - when prtExVcPbxTsCvServiceSlot=noConnect."
::= {prtExVcPbxTsEntry 13}
-- The following tables contains information specific to
-- the isdn access modules
prtIsdnCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtIsdnCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the table objects is valid only
to the TmpCnfg entry."
::= { prtIsdnCnfg 1}
prtIsdnCnfgEntry OBJECT-TYPE
SYNTAX PrtIsdnCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtIsdnCnfgIdx, prtIsdnSltIdx, prtIsdnPrtIdx}
::= { prtIsdnCnfgTable 1}
PrtIsdnCnfgEntry ::=
SEQUENCE {
prtIsdnCnfgIdx Integer32,
prtIsdnSltIdx INTEGER,
prtIsdnPrtIdx Integer32,
prtIsdnConnect INTEGER,
prtIsdnSignalingProtocol INTEGER,
prtIsdnBasicRateLineTopology INTEGER,
prtIsdnMode INTEGER,
prtIsdnFilter INTEGER,
prtIsdnSimultaneousCall INTEGER,
prtIsdnNumOfAbstractTerm Integer32,
prtIsdnSwitchMode INTEGER,
prtIsdnAbSide INTEGER,
prtIsdnQsigRole INTEGER,
prtIsdnInterface INTEGER,
prtIsdnCallMode INTEGER,
prtIsdnCallBackTimeout Integer32
}
prtIsdnCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtIsdnCnfgEntry 1}
prtIsdnSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10(14),
io11(15),
io12(16),
kmxMlA (103),
kmxMlB (104),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid
For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'"
::= { prtIsdnCnfgEntry 2}
prtIsdnPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
For MAXcess the values will be:
exPrt1(1),
exPrt2(2),
exPrt3(3),
exPrt4(4),
For KM-2100 the port index is calculated as follows:
100*Slot+Ch"
::= { prtIsdnCnfgEntry 3}
prtIsdnConnect OBJECT-TYPE
SYNTAX INTEGER { no(2), yes(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates if the port is connected."
::= { prtIsdnCnfgEntry 4 }
prtIsdnSignalingProtocol OBJECT-TYPE
SYNTAX INTEGER
{
other(1), etsi(3), ess4(5), ess5(6), dms100(7),
ni1(9), ni2(10), ins64(17), ins1500(18), qsig(21),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute fixes which signaling protocol
is used at this port (D-Channel).
It is equivalent to isdnSignalingProtocol
in the isdn MIB."
DEFVAL { etsi }
::= { prtIsdnCnfgEntry 5 }
prtIsdnBasicRateLineTopology OBJECT-TYPE
SYNTAX INTEGER
{
pointToPoint(1),
pointToMultipoint(2),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is relevant for ISDN BRI only.
It is equivalent to isdnBasicRateLineTopology
in the isdn MIB."
::= { prtIsdnCnfgEntry 6 }
prtIsdnMode OBJECT-TYPE
SYNTAX INTEGER
{
dialup(1),
leased(2),
syncLeased(3),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute allows the user to configure the port as
leased(2) in case of connection to a TDM network."
::= { prtIsdnCnfgEntry 7}
prtIsdnFilter OBJECT-TYPE
SYNTAX INTEGER
{ notApplicable(1),
answerAll(2),
rejectAll(3),
selective(4),
callBack (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute allows the user to configure the port:
answerAll(2): accept all incoming calls,
rejectAll(3): reject all incoming calls,
selective(4): accept or reject according directory table.
callBack (5): In this mode the ISDN Ch will reject incoming calls
and will initiate call back to the rejected phone number."
::= { prtIsdnCnfgEntry 8}
prtIsdnSimultaneousCall OBJECT-TYPE
SYNTAX INTEGER
{ notApplicable(1),
accept(2), reject(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In case of simultaneous call (local,remote and remote,local):
accept(2): accept the incoming call,
reject(3): reject the incoming call."
::= { prtIsdnCnfgEntry 9}
prtIsdnNumOfAbstractTerm OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An object for KM2100/4 agents.
255=Not Applicable
When ISDN Standard = ETSI or NTT (European) the value should be 255 (NotApplicable)
else If ML speed is 64Kbps value should be 1.
If ML speed is 128Kbps value can be either 1 or 2 (user selection)."
::= { prtIsdnCnfgEntry 10}
prtIsdnSwitchMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
auto (2),
manual (3),
connect(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For KM2100.
auto - The call is initiated automatically by one of the IO cards connected
to KML.10(ISDN card) having ISDN Switch Mode.
manual - The call is initiated by the user manually, for KML.10
having ISDN Switch Mode (via mdlSCmd).
connect- The call is initiated 'immediately', for KML.10 having ISDN Switch Mode.
'immediately'- means: immediately after power-up (when product performed
Reset) OR, since this value appears in the active
configuration.
In this case, the call can be disconnected only by power-off of the
product or by changing this object to another value (or actual Remove
of the KML.10 relevant card).
notApplicable - For other card types."
::= { prtIsdnCnfgEntry 11}
prtIsdnAbSide OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
aSide (2),
bSide (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the QSIG side in layer 3.
This definition is from the QSIG Standard."
::= { prtIsdnCnfgEntry 12}
prtIsdnQsigRole OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
slave (2),
master (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the QSIG side in layer 1 & 2."
::= { prtIsdnCnfgEntry 13}
prtIsdnInterface OBJECT-TYPE
SYNTAX INTEGER
{
lt (1),
nt (2),
te (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It indicates the interface type:
lt = line termination
nt = network termination
te = terminal equipment."
::= { prtIsdnCnfgEntry 14}
prtIsdnCallMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
initiate (2),
listen (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the acceptance of incoming calls.
Initiate - Callout
Listen - Callin. "
::= { prtIsdnCnfgEntry 15}
prtIsdnCallBackTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only if 'prtIsdnFilter' is 'CallBack'
and determines how long to wait from receiving the incoming call
until initiating the call back call.
The vaules range should be '1..20 sec' and the default 10 sec."
::= { prtIsdnCnfgEntry 16}
prtIsdnEndpointTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtIsdnEndpointEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the table objects is valid only
to the TmpCnfg entry."
::= { prtIsdnCnfg 2}
prtIsdnEndpointEntry OBJECT-TYPE
SYNTAX PrtIsdnEndpointEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtIsdnEndpointCnfgIdx, prtIsdnEndpointSltIdx,
prtIsdnEndpointPrtIdx, prtIsdnEndpointIdx }
::= { prtIsdnEndpointTable 1}
PrtIsdnEndpointEntry ::=
SEQUENCE {
prtIsdnEndpointCnfgIdx Integer32,
prtIsdnEndpointSltIdx INTEGER,
prtIsdnEndpointPrtIdx Integer32,
prtIsdnEndpointIdx INTEGER,
prtIsdnEndpointTeiType INTEGER,
prtIsdnEndpointTeiValue Integer32,
prtIsdnEndpointSpid DisplayString,
prtIsdnEndpointBearerCh INTEGER,
prtIsdnEndpointRowStatus RowStatus
}
prtIsdnEndpointCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtIsdnEndpointEntry 1}
prtIsdnEndpointSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1(5),
io2(6),
io3(7),
io4(8),
io5(9),
io6(10),
io7(11),
io8(12),
io9(13),
io10(14),
io11(15),
io12(16),
kmxMlA (103),
kmxMlB (104),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In ?004 Unit the entries io6(10)..io12(16) are not valid
For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'"
::= { prtIsdnEndpointEntry 2}
prtIsdnEndpointPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
For MAXcess the values will be:
exPrt1(1),
exPrt2(2),
exPrt3(3),
exPrt4(4),
For KM-2100 the port index is calculated as follows:
100*Slot+Ch"
::= { prtIsdnEndpointEntry 3}
prtIsdnEndpointIdx OBJECT-TYPE
SYNTAX INTEGER { atei1(1), atei2(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Since more than one endpoint may be defined per
isdn entity, this field is a simple index.
It corresponds to isdnEndpointIdx in the isdn MIB."
-- DEFVAL { atei1 }
::= { prtIsdnEndpointEntry 4}
prtIsdnEndpointTeiType OBJECT-TYPE
SYNTAX INTEGER { dynamic(1), static(2), notApplicable(255) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of TEI (Terminal Endpoint Identifier)
used for this Terminal Endpoint. In case of dynamic(1),
the TEI value is selected by the switch. In
case of static(2), a valid TEI value has to be
entered in the isdnEndpointTeiValue object.
interface type as well as the Terminal Endpoint type.
static(2). On Basic Rate interfaces the default value
is dynamic(1) for isdn(63) Terminal Endpoints.
It corresponds to isdnEndpointTeiType in the isdn MIB."
::= { prtIsdnEndpointEntry 5}
prtIsdnEndpointTeiValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"When the TEI Type is static, the value of the TEI should be
between 0 and 63. Else, it is not selectable by user.
255 = notApplicable.
It corresponds to isdnEndpointTeiValue in the isdn MIB"
::= { prtIsdnEndpointEntry 6 }
prtIsdnEndpointSpid OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Service profile IDentifier (SPID) information
for this Terminal Endpoint. It is is composed of
9-20 numeric characters.
It corresponds to isdnEndpointSpid in the isdn MIB."
::= { prtIsdnEndpointEntry 7 }
prtIsdnEndpointBearerCh OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
anyChannel (2),
channelB1 (3),
channelB2 (4) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the selected dialing channel.
anyChannel - the system selects the dialing channel."
::= { prtIsdnEndpointEntry 8}
prtIsdnEndpointRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This field indicates whether to consider this endpoint or not.
The only possible supported RowStatus vaules are
active (1) and destroy (6)."
::= { prtIsdnEndpointEntry 9}
prtIsdnDirectoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtIsdnDirectoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the table objects is valid only
to the TmpCnfg entry."
::= { prtIsdnCnfg 3}
prtIsdnDirectoryEntry OBJECT-TYPE
SYNTAX PrtIsdnDirectoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtIsdnDirectoryCnfgIdx, prtIsdnDirectorySltIdx, prtIsdnDirectoryPrtIdx }
::= { prtIsdnDirectoryTable 1}
PrtIsdnDirectoryEntry ::=
SEQUENCE {
prtIsdnDirectoryCnfgIdx Integer32,
prtIsdnDirectorySltIdx INTEGER,
prtIsdnDirectoryPrtIdx Integer32,
prtIsdnDirectoryLocalAddr DisplayString,
prtIsdnDirectoryLocalSubAddr DisplayString,
prtIsdnDirectoryRemoteAddr DisplayString,
prtIsdnDirectoryRemoteSubAddr DisplayString,
prtIsdnDirectoryPrtNu Integer32,
prtIsdnDirectoryTeiId Integer32,
prtIsdnDirectoryRowStatus RowStatus,
prtIsdnDirectoryLocalAddr2 DisplayString,
prtIsdnDirectoryLocalSubAddr2 DisplayString,
prtIsdnDirectoryRemoteAddr2 DisplayString,
prtIsdnDirectoryRemoteSubAddr2 DisplayString
}
prtIsdnDirectoryCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtIsdnDirectoryEntry 1}
prtIsdnDirectorySltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1(5),
io2(6),
io3(7),
io4(8),
io5(9),
io6(10),
io7(11),
io8(12),
io9(13),
io10(14),
io11(15),
io12(16),
kmxMlA (103),
kmxMlB (104),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
For MX300/30 ports:
io1(5) = isdn1(5) and io2(6) = isdn2(6).
In ?004 Unit the entries io6(10)..io12(16) are not valid
For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'"
::= { prtIsdnDirectoryEntry 2}
prtIsdnDirectoryPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For MAXcess this is the internal port number: 101, 102,....
For KM-2100 the port index is calculated as follows:
100*Slot+Ch"
::= { prtIsdnDirectoryEntry 3}
prtIsdnDirectoryLocalAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE(17..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the local address associated with this
entry.
- For MX: Size=17 , Default=0 (17 characters)
- For KM: Size=20, Default=blank (20 characters) "
::= { prtIsdnDirectoryEntry 4}
prtIsdnDirectoryLocalSubAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE(4..6))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the local subaddress associated with this
entry.
- For MX: Size=6 , Default=0 (6 characters)
- For KM: Size=4 , Default=blank (4 characters)"
::= { prtIsdnDirectoryEntry 5}
prtIsdnDirectoryRemoteAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE(17..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the remote address associated with this
entry.
- For MX: Size=17 , Default=0 (17 characters)
- For KM: Size=20, Default=blank (20 characters)"
::= { prtIsdnDirectoryEntry 6}
prtIsdnDirectoryRemoteSubAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE(4..6))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the remote subaddress associated with this
entry.
- For MX: Size=6 , Default=0 (6 characters)
- For KM: Size=4 , Default=blank (4 characters)"
::= { prtIsdnDirectoryEntry 7}
prtIsdnDirectoryPrtNu OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the external port number connected to
this entry."
DEFVAL { 1 }
::= { prtIsdnDirectoryEntry 8}
prtIsdnDirectoryTeiId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the abstract terminal id if relevant,
connected to this entry."
DEFVAL { 1 }
::= { prtIsdnDirectoryEntry 9}
prtIsdnDirectoryRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the status for the row. It allows to know
whether to consider this row or not.
The only possible supported RowStatus vaules are
active (1) and destroy (6)."
::= { prtIsdnDirectoryEntry 10}
prtIsdnDirectoryLocalAddr2 OBJECT-TYPE
SYNTAX DisplayString (SIZE(17..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the second local address associated with this
entry.
- For MX: Size=17 , Default=0 (17 characters)
- For KM: Size=20, Default=blank (20 characters)"
::= { prtIsdnDirectoryEntry 11}
prtIsdnDirectoryLocalSubAddr2 OBJECT-TYPE
SYNTAX DisplayString (SIZE(4..6))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the second local subaddress associated with this
entry.
- For MX: Size=6 , Default=0 (6 characters)
- For KM: Size=4 , Default=blank (4 characters)"
::= { prtIsdnDirectoryEntry 12}
prtIsdnDirectoryRemoteAddr2 OBJECT-TYPE
SYNTAX DisplayString (SIZE(17..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the second remote address associated with this
entry.
- For MX: Size=17 , Default=0 (17 characters)
- For KM: Size=20, Default=blank(20 characters) "
::= { prtIsdnDirectoryEntry 13}
prtIsdnDirectoryRemoteSubAddr2 OBJECT-TYPE
SYNTAX DisplayString (SIZE(4..6))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the second remote subaddress associated with this
entry.
- For MX: Size=6 , Default=0 (6 characters)
- For KM: Size=4 , Default=blank (4 characters) "
::= { prtIsdnDirectoryEntry 14}
-- This table is an extension for new version of MAXcess
-- modules.
prtFrPlusCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtFrPlusCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtFrPlusCnfg 1}
prtFrPlusCnfgEntry OBJECT-TYPE
SYNTAX PrtFrPlusCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtFrPlusCnfgIdx, prtFrPlusSltIdx, prtFrPlusPrtIdx }
::= { prtFrPlusCnfgTable 1}
PrtFrPlusCnfgEntry ::=
SEQUENCE {
prtFrPlusCnfgIdx Integer32,
prtFrPlusSltIdx INTEGER,
prtFrPlusPrtIdx Integer32,
prtFrPlusNotSegmentedPriorities OCTET STRING
}
prtFrPlusCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtFrPlusCnfgEntry 1}
prtFrPlusSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot Index.
For ISDN BRI Ports of MX300/30,
io1(5) = isdn1(5) and io2(6) = isdn2(6)."
::= { prtFrPlusCnfgEntry 2}
prtFrPlusPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
This port number should be:
- for ISDN cards: inPrt1(101)->inPrt50(150)
- for MHS1 card : exPrt1(1)
- for MHS3, MLS3 cards: exPrt1(1)->exPrt3(3)
- for MLS6 cards: exPrt1(1)->exPrt6(6)."
::= { prtFrPlusCnfgEntry 3}
prtFrPlusNotSegmentedPriorities OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is relevant only for FR+ protocol and
asks the MXcess NOT to segment data with specified
priorities: from LSB:
bit 1 is for priority 1,
bit 2 is for priority 2, .... till bit 7 for priority 7.
- a priority selected to be segmented : its bit will be '0'
- a priority not to be segmented : its bit will be '1'
Default is 00000000; i.e, segment all priorities."
DEFVAL { '00'H }
::= { prtFrPlusCnfgEntry 4 }
-- This table is an extension of prtExPh1MlCnfgTable for MTML cards
-- of MP-2200 and MP-2100
prtMl4CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtMl4CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is an extension table for MTML-4 card parameters."
::= {prtMl4Cnfg 1}
prtMl4CnfgEntry OBJECT-TYPE
SYNTAX PrtMl4CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtMl4CnfgIdx, prtMl4SltIdx, prtMl4PrtIdx }
::= { prtMl4CnfgTable 1}
PrtMl4CnfgEntry ::=
SEQUENCE {
prtMl4CnfgIdx Integer32,
prtMl4SltIdx INTEGER,
prtMl4PrtIdx INTEGER,
prtMl4SigProfile INTEGER,
prtMl4CGA INTEGER,
prtMl4Oos INTEGER,
prtMl4VoiceOos OCTET STRING,
prtMl4DataOos OCTET STRING,
prtMl4Service INTEGER,
prtMl4IpAddress IpAddress,
prtMl4IpMask IpAddress,
prtMl4SignalingMode INTEGER,
prtMl4EchoCanceler INTEGER,
prtMl4OosErrorSource INTEGER,
prtMl4OosEntryThreshold Integer32,
prtMl4OosExitThreshold Integer32,
prtMl4LogicalLinkId Integer32,
prtMl4DedicatedTs Integer32,
prtMl4RemCrc INTEGER,
prtMl4CrossConnectLevel INTEGER,
prtMl4PppEchoFailDetection INTEGER,
prtMl4EcanCasControl INTEGER
}
prtMl4CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. The write operation is valid only
to the TmpCnfg."
::= { prtMl4CnfgEntry 1}
prtMl4SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted."
::= { prtMl4CnfgEntry 2}
prtMl4PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
exPrt3 (3),
exPrt4 (4),
exPrt5 (5),
exPrt6 (6),
exPrt7 (7),
exPrt8 (8),
inPrt1 (101),
inPrt2 (102),
inPrt3 (103),
inPrt4 (104),
inPrt5 (105),
inPrt6 (106),
inPrt7 (107),
inPrt8 (108),
inPrt9 (109),
inPrt10 (110),
inPrt11 (111),
inPrt12 (112),
inPrt13 (113),
inPrt14 (114),
inPrt15 (115),
inPrt16 (116),
inPrt17 (117),
inPrt18 (118),
inPrt19 (119),
inPrt20 (120),
inPrt21 (121),
inPrt22 (122),
inPrt23 (123),
inPrt24 (124),
inPrt25 (125),
inPrt26 (126),
inPrt27 (127),
inPrt28 (128),
inPrt29 (129),
inPrt30 (130),
inPrt31 (131),
inPrt32 (132),
inPrt33 (133),
inPrt34 (134),
inPrt35 (135),
inPrt36 (136),
inPrt37 (137),
inPrt38 (138),
inPrt39 (139),
inPrt40 (140),
inPrt41 (141),
inPrt42 (142),
inPrt43 (143),
inPrt44 (144),
inPrt45 (145),
inPrt46 (146),
inPrt47 (147),
inPrt48 (148),
inPrt49 (149),
inPrt50 (150),
inPrt51 (151),
inPrt52 (152),
inPrt53 (153),
inPrt54 (154),
inPrt55 (155),
inPrt56 (156),
inPrt57 (157),
inPrt58 (158),
inPrt59 (159),
inPrt60 (160),
inPrt61 (161),
inPrt62 (162),
inPrt63 (163),
inPrt64 (164),
inPrt65 (165),
inPrt66 (166),
inPrt67 (167),
inPrt68 (168),
inPrt69 (169),
inPrt70 (170),
inPrt71 (171),
inPrt72 (172),
inPrt73 (173),
inPrt74 (174),
inPrt75 (175),
inPrt76 (176),
inPrt77 (177),
inPrt78 (178),
inPrt79 (179),
inPrt80 (180),
inPrt81 (181),
inPrt82 (182),
inPrt83 (183),
inPrt84 (184)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number."
::= { prtMl4CnfgEntry 3}
prtMl4SigProfile OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
p1 (3),
p2 (4),
p3 (5),
p4 (6),
p5 (7),
perTS (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Signaling Profile of the port.
none - when the Frame is G732N (no MF) or Unframed.
p1 = profile 1
p2 = profile 2
p3 = profile 3
p4 = profile 4
p5 = profile 5
perTS = when Signaling Profile is selected per TS."
::= {prtMl4CnfgEntry 4}
prtMl4CGA OBJECT-TYPE
SYNTAX INTEGER {
none (1),
trans(2),
full (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object selects the method used to signal the CGA state
to the other end, through the main link.
'none' - non-transparent mode. When one of the links
(main) will be in Out Of Service state, both
'Data/Voice Oos' and 'Oos' will be
transmitted to the other end.
'trans' - when one of the links (main) will be in Out
Of Service state, 'Data/Voice Oos' will be
transmitted to the other end.
'full' - fully-transparent mode. When one of the links
(main) will be in Out Of Service state,
neither 'Data/Voice Oos' nor 'Oos' will
be transmitted to the other end."
::= { prtMl4CnfgEntry 5 }
prtMl4Oos OBJECT-TYPE
SYNTAX INTEGER
{
notSupported (2),
forcedIdle (3),
forcedBusy (4),
busyIdle (5),
idleBusy (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"'idle' = '0' = on-hook, idle state
'busy' = '1' = off-hook, busy state
'forcedIdle' = SP = both A and B signaling bits are forced
to '0' during out-of-service periods.
'forcedBusy' = MK = both A and B signaling bits are forced
to '1' during out-of-service periods.
'busyIdle' = MK_SP = A and B bits are forced to '1' for
2.5 seconds; then they are switched to '0'
until out-of-service condition disappears.
'idleBusy' = SP_MK = A and B bits are forced to '0' for
2.5 seconds; then they are switched to '1'
until out-of-service condition disappears.
- for T1: '0'=0 ; '1'=1
- for E1: '0'=1 ; '1'=0 "
::= { prtMl4CnfgEntry 6 }
prtMl4VoiceOos OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Voice Out-Of-Service code. Valid range: (0 - FF HEX).
For agents that do not support this feature, the value will
always be 0."
::= { prtMl4CnfgEntry 7 }
prtMl4DataOos OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data Out-Of-Service code. Valid range: (0 - FF HEX).
For agents that do not support this feature, the value will
always be 0."
::= { prtMl4CnfgEntry 8 }
prtMl4Service OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
leasedLine (2),
v51 (3),
v52Master (4),
v52Slave (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Link Service.
leasedLine - usual TDM interface.
v51 - V5.1 interface.
v52Master - V5.2 Link to Local Exchange.
v52Slave - a ML that is transferred to the v52Master."
::= {prtMl4CnfgEntry 9}
prtMl4IpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP Address of the port."
::= {prtMl4CnfgEntry 10}
prtMl4IpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP subnet mask of the port."
::= {prtMl4CnfgEntry 11}
prtMl4SignalingMode OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1),
cas(2),
ccs(3),
robbedBit(4),
other (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Refers to the signaling mode of the port (or framer module).
notApplicable(1)- means that no framer is needed for this port (no signaling),
or that this object is not relevant.
cas(2) means Channel Associated Signaling. Used for E1 Links.
ccs(3) is the Common Channel Signaling (the signaling is not within
the channels time slot - a TS for signaling is used).
robbedBit(4) is a method implementing 7 bits for the voice and 1 bit
dedicated for signaling. Used for T1 Links.
other (5)- Signaling generally exists though not specifically according
to one of the values listed ; this port uses a framer in this case."
::= {prtMl4CnfgEntry 12}
prtMl4EchoCanceler OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Echo canceler activation."
::= {prtMl4CnfgEntry 13}
prtMl4OosErrorSource OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
framing (3),
bpv (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OOS (Out-of-Service) Error Source.
This object is applicable for T1 ports only."
::= {prtMl4CnfgEntry 14}
prtMl4OosEntryThreshold OBJECT-TYPE
SYNTAX Integer32 (0..999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the number of Errors per Second that determine the
minimum unacceptable noise level. This value will be the Entry Threshold
to the OOS (Out-of-Service) state.
This object is applicable only when prtMl4OosErrorSource=framing(3) or bpv(4).
0=notApplicable."
::= { prtMl4CnfgEntry 15}
prtMl4OosExitThreshold OBJECT-TYPE
SYNTAX Integer32 (0..99)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the number of consecutive Error-Free-Seconds before
going from OOS state to Normal state. This value will be the Exit Threshold
from the OOS (Out-of-Service) state.
Units=seconds
This object is applicable only when prtMl4OosErrorSource=framing(3) or bpv(4).
0=notApplicable."
::= { prtMl4CnfgEntry 16}
prtMl4LogicalLinkId OBJECT-TYPE
SYNTAX Integer32 (0..257)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines for a V5.2 Master ML the Logical Link Id.
Valid values are: 0..256.
NA=257."
::= { prtMl4CnfgEntry 17}
prtMl4DedicatedTs OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique number to identify Dedicated TS of the E1 port (V5.2).
It is applicable only when prtMl4Service=v52Slave and
prtExPh1MlInbandMng selected is dedicatedTs, dedicatedPpp or dedicatedFr.
1..31 - Dedicated TS of E1
255 - notApplicable
Other values are invalid."
::= { prtMl4CnfgEntry 18}
prtMl4RemCrc OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the E1 of the Remote device
connected to this E1 port, will have CRC-4 or not."
::= { prtMl4CnfgEntry 19 }
prtMl4CrossConnectLevel OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
ds0 (2),
ds1 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the cross connect is
on DS1 or DS0 (time-slots) level.
When cross connect level is ds1, Destination Slot
is indicated by prtGenCnfgLinkToSlot,
Destination Port is indicated by prtGenCnfgLinkToPort.
For Unframed Line Type, cross connect level can be either
notApplicable (NC=not connected) or DS1.
Otherwise, default value is ds0."
::= { prtMl4CnfgEntry 20 }
prtMl4PppEchoFailDetection OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the PPP Echo is taken into account
for its Fail Detection.
This object is relevant when Inband Mng between devices is Dedicated TS PPP.
Default=Disable.
Enable - will be selected mainly when a T1/E1 Ring exists and between 2 adjacent
Ring devices there is another device or Net, that causes these Ring devices
not to sense that the PPP connection between them is lost. In this case,
Echo Request should be initiated by the port."
::= { prtMl4CnfgEntry 21 }
prtMl4EcanCasControl OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables/disables ECAN (Echo Canceller) control activation/deactivation
sent via the A, B, C, D multiframe signaling BITs."
::= { prtMl4CnfgEntry 22 }
--prtAcmCnfgTable defines the parameters of the
--ACM cards family external ports 1-8
prtAcmCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtAcmCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a table for ACM port parameters."
::= {prtAcmCnfg 1}
prtAcmCnfgEntry OBJECT-TYPE
SYNTAX PrtAcmCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtAcmCnfgIdx, prtAcmSltIdx, prtAcmPrtIdx }
::= { prtAcmCnfgTable 1}
PrtAcmCnfgEntry ::=
SEQUENCE {
prtAcmCnfgIdx Integer32,
prtAcmSltIdx INTEGER,
prtAcmPrtIdx INTEGER,
prtAcmConnect INTEGER,
prtAcmActiveState INTEGER,
prtAcmAlrString DisplayString
}
prtAcmCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. The write operation is valid only
to the TmpCnfg."
::= { prtAcmCnfgEntry 1}
prtAcmSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted."
::= { prtAcmCnfgEntry 2}
prtAcmPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
exPrt3 (3),
exPrt4 (4),
exPrt5 (5),
exPrt6 (6),
exPrt7 (7),
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
exPrt11 (11) ,
exPrt12 (12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number."
::= { prtAcmCnfgEntry 3}
prtAcmConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
connected or not. Only a connected port can perform activity."
::= {prtAcmCnfgEntry 4}
prtAcmActiveState OBJECT-TYPE
SYNTAX INTEGER
{
low (2),
high (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Electric Active State of the port."
::= {prtAcmCnfgEntry 5}
prtAcmAlrString OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..35))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Alarm string selected by user for the Inbound ports.
This object is applicable only for the Inbound Ports: ext-5..ext-12.
For the Outbound Ports (ext-1..ext-4), the size of this string will be 0."
::= {prtAcmCnfgEntry 6}
--prtE2CnfgTable defines the parameters of the
--E2 card ports
prtE2CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtE2CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a table for E2 port parameters."
::= {prtE2Cnfg 1}
prtE2CnfgEntry OBJECT-TYPE
SYNTAX PrtE2CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtE2CnfgIdx, prtE2SltIdx, prtE2PrtIdx }
::= { prtE2CnfgTable 1}
PrtE2CnfgEntry ::=
SEQUENCE {
prtE2CnfgIdx Integer32,
prtE2SltIdx INTEGER,
prtE2PrtIdx INTEGER,
prtE2Connect INTEGER,
prtE2MngOnNationalBit INTEGER
}
prtE2CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. The write operation is valid only
to the TmpCnfg."
::= { prtE2CnfgEntry 1}
prtE2SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted."
::= { prtE2CnfgEntry 2}
prtE2PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number."
::= { prtE2CnfgEntry 3}
prtE2Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
connected or not. Only a connected port can perform activity."
::= {prtE2CnfgEntry 4}
prtE2MngOnNationalBit OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether National Bit will be used for
Management or not."
::= {prtE2CnfgEntry 5}
--prtLanWanCnfgTable defines the parameters of the Lan-Wan ports
--(for HS-ETUB MP card)
prtLanWanCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtLanWanCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a table for Lan-Wan port parameters."
::= {prtLanWanCnfg 1}
prtLanWanCnfgEntry OBJECT-TYPE
SYNTAX PrtLanWanCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtLanWanCnfgIdx, prtLanWanSltIdx, prtLanWanPrtIdx }
::= { prtLanWanCnfgTable 1}
PrtLanWanCnfgEntry ::=
SEQUENCE {
prtLanWanCnfgIdx Integer32,
prtLanWanSltIdx INTEGER,
prtLanWanPrtIdx Integer32,
prtLanWanMode INTEGER,
prtLanWanDestIf Integer32,
prtLanWanEgressVlanMode INTEGER,
prtLanWanL2Protocol INTEGER,
prtLanWanStpPriority Integer32,
prtLanWanStpCost Integer32,
prtLanWanToLanVlanMode INTEGER,
prtLanWanVlanId Integer32,
prtLanWanVlanPriority Integer32,
prtLanWanMtu Integer32,
prtLanWanVlanType INTEGER
}
prtLanWanCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. The write operation is valid only
to the TmpCnfg."
::= {prtLanWanCnfgEntry 1}
prtLanWanSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates a unique slot position where the module is inserted."
::= {prtLanWanCnfgEntry 2}
prtLanWanPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates a unique number to identify a port
in a specific card.
Generally, for MP-210X/2200, the Port Index will be according to the
external/internal port number:
- exPrtX : X
- inPrtX : 100 + X
For FCD-155, refer to device specification"
::= {prtLanWanCnfgEntry 3}
prtLanWanMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
bridge (2),
bridgeAndStp (3),
layer3SubnetSwitch(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines the working mode of this port.
For FCD155, layer3SubnetSwitch is not applicable"
::= {prtLanWanCnfgEntry 4}
prtLanWanDestIf OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines the Destination Interface for the frames
received by this port.
- Switching Table = 100 (it means that the destination interface
will be determined by the Switching Table)
- inPrtX (internal-X port): 100 + X .
For FCD-155 this object is not applicable =0 "
::= {prtLanWanCnfgEntry 5}
prtLanWanEgressVlanMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
unmodified (2),
tag (3),
doubleTag (4),
untag (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines what to do with the VLAN frames that exit
via the WAN side of the port.
This object is not applicable when prtLanWanMode=l3SubnetSwitch(4)."
::= {prtLanWanCnfgEntry 6}
prtLanWanL2Protocol OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
ppp (3),
hdlc (4),
pppoHdlc (5),
mlppp (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"L2 Protocol.
When prtLanWanMode=l3SubnetSwitch(4), the only valid value is ppp(3)."
::= {prtLanWanCnfgEntry 7}
prtLanWanStpPriority OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the priority field which is contained in the first
(in network byte order) octet of the (2 octet long) Port ID."
::= {prtLanWanCnfgEntry 8}
prtLanWanStpCost OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The contribution of this port to the path cost of paths towards
the spanning tree root which include this port. 802.1D-1990 recommends
that the default value of this parameter be in inverse proportion
to the speed of the attached LAN."
::= {prtLanWanCnfgEntry 9}
prtLanWanToLanVlanMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
unmodified (2),
tag (3),
doubleTag (4),
untag (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines what to do with the VLAN frames that come from
WAN side of the port and exit towards one of the LAN ports.
This object is applicable only when prtLanWanDestIf=100 or 101
(Switching Table or inPrt1)."
::= {prtLanWanCnfgEntry 10}
prtLanWanVlanId OBJECT-TYPE
SYNTAX Integer32 (0..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the VLAN Id attached to a frame, when the relevant
Vlan Mode (prtLanWanEgressVlanMode or prtLanWanToLanVlanMode) is
tag or doubleTag.
0=not applicable."
::= {prtLanWanCnfgEntry 11}
prtLanWanVlanPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the VLAN Priority attached to a frame, when the relevant
Vlan Mode (prtLanWanEgressVlanMode or prtLanWanToLanVlanMode) is
tag or doubleTag.
Valid values: 0..7
255=not applicable."
::= {prtLanWanCnfgEntry 12}
prtLanWanMtu OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The size of the largest packet which can be sent/received on the interface,
specified in octets.
Valid values change per device.
0=not applicable."
::= {prtLanWanCnfgEntry 13}
prtLanWanVlanType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
portBasedVlan (2),
ieee802dot1q (3),
ieee802dot1qTaggedOnly (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This oject indicates type of VLAN this port is assigned to.
Port Base Vlan parameters are defined by objects under
radBridgePortBaseVlan"
::= { prtLanWanCnfgEntry 14}
--
-- The following table includes the IP addresses of all the NMS to which
-- Traps will be sent
--
--mngTrapIpTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF MngTrapIpEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table indicates the destination address of the traps.
-- Internally it will be limited to ten addresses. "
-- ::= { agnt 7 }
--
--mngTrapIpEntry OBJECT-TYPE
-- SYNTAX MngTrapIpEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- INDEX { mngTrapIpIdx }
-- ::= { mngTrapIpTable 1 }
--
--MngTrapIpEntry ::=
-- SEQUENCE {
-- mngTrapIpIdx Integer32,
-- mngTrapIpIP IpAddress,
-- mngTrapIpIPMask IpAddress
-- }
--
--mngTrapIpIdx OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- " This value indicates an index of a specific IP address"
-- ::= { mngTrapIpEntry 1 }
--
--mngTrapIpIP OBJECT-TYPE
-- SYNTAX IpAddress
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "This value indicates the destination addresses of the traps. "
-- ::= { mngTrapIpEntry 2 }
--
--mngTrapIpIPMask OBJECT-TYPE
-- SYNTAX IpAddress
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "This value indicates the mask of the destination addresses of the traps. "
-- ::= { mngTrapIpEntry 3 }
--
--
-- Traps
--NOTIFICATIONS
muxHubEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for ."
::= { muxHub 0 }
alarmsTrap NOTIFICATION-TYPE
OBJECTS { alrBufDescription }
STATUS current
DESCRIPTION
"This trap is sent whenever alarm occurs in the agent."
::= { muxHubEvents 1 }
sanityTrap NOTIFICATION-TYPE
OBJECTS { agnSSanityCheckStatus, agnCSaveCnfgIdxCmd }
STATUS current
DESCRIPTION
"This trap is sent after a data base update.
It returns the sanity result status and the configuration no.
checked.
If the result is of Flip DB Sanity Check, the configuration
no. sent will be 0.
If the result is of Variant Sanity Check, the configuration
no. sent will be 100."
::= { muxHubEvents 2 }
cnfgFlipTrap NOTIFICATION-TYPE
OBJECTS { agnSActiveCnfg }
STATUS current
DESCRIPTION
"This trap is sent upon change of the active Configuration DB.
Attached, is the new active Configuration no."
::= { muxHubEvents 3 }
flipDbChangeTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent upon change of the active Flip tables
(Flip DB)."
::= { muxHubEvents 4 }
statusChangedTrap NOTIFICATION-TYPE
OBJECTS { agnLed }
STATUS current
DESCRIPTION
"This trap is sent upon any change of the LEDs status."
::= { muxHubEvents 5 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\ethIf.txt
--
--
-- File: EthIf.txt
--
--Ethernet Interface
ethIf OBJECT IDENTIFIER ::= {diverseIfWanGen 1} --Ethernet Interface
ethIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { ethIf 1}
ethIfEntry OBJECT-TYPE
SYNTAX EthIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {ethIfIdx}
::= {ethIfTable 1}
EthIfEntry ::=
SEQUENCE {
ethIfIdx Integer32,
ethMode INTEGER,
ethBridgingMode INTEGER,
ethEncapsulationCRCMode INTEGER,
ethBackPressure INTEGER,
ethLimit4 INTEGER,
ethSkipInitReset INTEGER,
ethMulticastBlock INTEGER,
ethBroadcastBlock INTEGER,
ethSpeed INTEGER,
ethRip2 INTEGER,
ethPortPriority INTEGER,
ethPortMngEnable INTEGER,
ethFlowCtrlMacAddress MacAddress,
ethRateLimit Integer32,
ethJumboFrameEnable INTEGER,
ethAutoMdiXEnable INTEGER,
ethPortDataEnable INTEGER,
ethIfUse Integer32,
ethLineOam INTEGER,
ethRoutingProtocol INTEGER,
ethMdiXManualSwitch INTEGER,
ethDot1xEnable INTEGER,
ethPartnerRateMode INTEGER,
ethDot1xPortRole INTEGER
}
ethIfIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique index of the ethernet interface/port."
::= {ethIfEntry 1}
ethMode OBJECT-TYPE
SYNTAX INTEGER
{
halfDuplex (1),
fullDuplex (2),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Ethernet mode of operation."
::= {ethIfEntry 2}
ethBridgingMode OBJECT-TYPE
SYNTAX INTEGER
{
filtered (1),
transparent (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the bridging mode of the Ethernet
interface. "
::= {ethIfEntry 3}
ethEncapsulationCRCMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
withCRC (2),
withoutCRC (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object define the encapsulation type requested for the
Ethernet interface. It indicates if we transfer the Ethernet
frame to the other side with or without the CRC. "
::= {ethIfEntry 4}
ethBackPressure OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether to enable or disable Back pressure.
Back Pressure is a flow control parameter. "
::= {ethIfEntry 5}
ethLimit4 OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter determine the Back off algorithm mode.
Every 4 following collisions the Framer will be thrown out
(4 times more than usuall)."
::= {ethIfEntry 6}
ethSkipInitReset OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
notSkip (2),
skip (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether read status on reset. "
::= {ethIfEntry 7}
ethMulticastBlock OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
unBlock (2),
block (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether to send multicast message to WAN from LAN or not. "
::= {ethIfEntry 8}
ethBroadcastBlock OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
unBlock (2),
block (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether to send broadcast message to WAN from LAN or not."
::= {ethIfEntry 9}
ethSpeed OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
s10Mbps (2),
s100Mbps (3),
s1Gbps (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines the line speed."
::= {ethIfEntry 10}
ethRip2 OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether to send RIP II message
to WAN from LAN or not"
::= {ethIfEntry 11}
ethPortPriority OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
fixed (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines if priority is to
be considered for this Port."
::= {ethIfEntry 12}
ethPortMngEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3),
localOnly (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether management data can pass through this Port.
localOnly (4) - Only local device can be managed via this port."
::= {ethIfEntry 13}
ethFlowCtrlMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In case of flow control - transmit frame with this specific MAC address
to inform the other end to stop sending frames.
Default: 01.80.C2.00.00.01."
::= {ethIfEntry 14}
ethRateLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines the Rate Limit of the line, in Mbps."
::= {ethIfEntry 15}
ethJumboFrameEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether to support Jumbo Frame or not."
::= {ethIfEntry 16}
ethAutoMdiXEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether to support
automatic change between MDI and MDI[X]."
::= {ethIfEntry 17}
ethPortDataEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether this port is enabled
for data (that is not management).
no(2) - management can run on this port
yes(3) - both management and payload data can run on this port."
::= {ethIfEntry 18}
ethIfUse OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines the use of the port.
1=NET
2=USER ."
::= {ethIfEntry 19}
ethLineOam OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
passive (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines the working mode of 802.AH OAM mechanism."
::= {ethIfEntry 20}
ethRoutingProtocol OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
proprietary (3),
rip2 (4),
rip1and2 (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines the routing protocol
used above ETH port."
::= {ethIfEntry 21}
ethMdiXManualSwitch OBJECT-TYPE
SYNTAX INTEGER
{
crossOver (1),
straightThrough (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter sets the port to be MDI-X (cross-over) or
MDI (straight-through).
It is applicable only when ethAutoMdiXEnable = no, namely,
only when the automatic MDI/MDIX crossover function is disabled."
::= {ethIfEntry 22}
ethDot1xEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines if the Port-Based Network Access Protocol
(IEEE-802.1x) is enabled for the Ethernet Port."
::= {ethIfEntry 23}
ethPartnerRateMode OBJECT-TYPE
SYNTAX INTEGER
{
manual (1),
automatic (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For converters having couples of ports, where each couple contains
a port with an SFP connector and a port with a RJ connector, this
parameter is relevant for the SFP port. It affects Rate configuration
of its partner (RJ port).
manual - user can configure manually ETH parameters of RJ port (e.g
Autonegotiation, Max Capability Advertised, etc...)
automatic - SFP Rate will be enforced on the RJ port. In this mode,
user cannot configure the Rate related parameters of the
RJ port (e.g Autonegotiation, Max Capability Advertised, etc...)"
::= {ethIfEntry 24}
ethDot1xPortRole OBJECT-TYPE
SYNTAX INTEGER
{
authenticator (1),
supplicant (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determine the functionality of the port in
the Port-Based Network Access Protocol (IEEE-802.1x) -
either Authenticator or Supplicant."
::= {ethIfEntry 25}
ethIfPerformance OBJECT IDENTIFIER ::= {ethIf 2}
ethIfCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthIfCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Ethernet Current table.
When the index specifies the Ethernet interface (only), the counters
are for an interval of 15 minutes."
::= { ethIfPerformance 1}
ethIfCurrentEntry OBJECT-TYPE
SYNTAX EthIfCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Ethernet Current table."
INDEX {ethIfCurrentIndex}
::= {ethIfCurrentTable 1}
EthIfCurrentEntry ::=
SEQUENCE {
ethIfCurrentIndex
Integer32,
ethIfCurrentStatus
OCTET STRING,
ethIfCurrentInFrames
Gauge32,
ethIfCurrentInOctets
Gauge32,
ethIfCurrentAlignmentErrors
Gauge32,
ethIfCurrentFCSErrors
Gauge32,
ethIfCurrentLengthError
Gauge32,
ethIfCurrentOutFrames
Gauge32,
ethIfCurrentOutOctets
Gauge32,
ethIfCurrentSingleCollisionFrames
Gauge32,
ethIfCurrentMultipleCollisionFrames
Gauge32,
ethIfCurrentDeferredTransmissions
Gauge32,
ethIfCurrentLateCollisions
Gauge32,
ethIfCurrentCarrierSenseErrors
Gauge32,
ethIfCurrentInputCongestionDropped
Gauge32,
ethIfCurrentOutputCongestionDropped
Gauge32,
ethIfCurrentOverflowInFrames
Gauge32,
ethIfCurrentOverflowInOctets
Gauge32,
ethIfCurrentOverflowFCSErrors
Gauge32,
ethIfCurrentOverflowOutFrames
Gauge32,
ethIfCurrentOverflowOutOctets
Gauge32,
ethIfCurrentOverflowMultipleCollisionFrames
Gauge32,
ethIfCurrentInUnicastFrames
Gauge32,
ethIfCurrentOutUnicastFrames
Gauge32,
ethIfCurrentInMulticastFrames
Gauge32,
ethIfCurrentOutMulticastFrames
Gauge32,
ethIfCurrentInBroadcastFrames
Gauge32,
ethIfCurrentOutBroadcastFrames
Gauge32,
ethIfCurrentInDiscardFrames
Gauge32,
ethIfCurrentOutDiscardFrames
Gauge32,
ethIfCurrentInPauseFrames
Gauge32,
ethIfCurrentOutPauseFrames
Gauge32,
ethIfCurrentOverflowInUnicastFrames
Gauge32,
ethIfCurrentOverflowOutUnicastFrames
Gauge32,
ethIfCurrentOverflowInMulticastFrames
Gauge32,
ethIfCurrentOverflowOutMulticastFrames
Gauge32,
ethIfCurrentOverflowInBroadcastFrames
Gauge32,
ethIfCurrentOverflowOutBroadcastFrames
Gauge32,
ethIfCurrentOverflowInDiscardFrames
Gauge32,
ethIfCurrentOverflowOutDiscardFrames
Gauge32,
ethIfCurrentOverflowInPauseFrames
Gauge32,
ethIfCurrentOverflowOutPauseFrames
Gauge32
}
ethIfCurrentIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the Ethernet interface.
It may be ifIndex.
For some devices (e.g RICi-622GE), supporting several types of
intervals, this index will be a concatenation of the port index
and interval type.
Interval type can indicate: 1 minute, 15 minutes, 1 hour, 24 hours.
For the exact formula, see device specification."
::= { ethIfCurrentEntry 1 }
ethIfCurrentStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the current interval:
0 - Valid.
1 - redundantLinkSwitch - the link has been switched
by a redundancy mechanism.
2 - discontinuity - module was partialy out.
4 - notValid - module is out."
::= { ethIfCurrentEntry 2 }
ethIfCurrentInFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames,
encountered by the Ethernet interface in the current interval."
::= { ethIfCurrentEntry 3 }
ethIfCurrentInOctets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received octets,
encountered by the Ethernet interface in the current interval."
::= { ethIfCurrentEntry 4 }
ethIfCurrentAlignmentErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames,
which are not complete (The result of dividing the number
of bits by 8 is not an Integer), encountered by the Ethernet
interface in the current interval."
::= { ethIfCurrentEntry 5 }
ethIfCurrentFCSErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames
that didn't pass the FCS test, encountered by the Ethernet
interface in the current interval."
::= { ethIfCurrentEntry 6 }
ethIfCurrentLengthError OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames
with length error, encountered by the Ethernet interface in
the current interval."
::= { ethIfCurrentEntry 7 }
ethIfCurrentOutFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted frames,
encountered by the Ethernet interface in the current interval."
::= { ethIfCurrentEntry 8 }
ethIfCurrentOutOctets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted octets,
encountered by the Ethernet interface in the current interval."
::= { ethIfCurrentEntry 9 }
ethIfCurrentSingleCollisionFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of successfully
transmitted frames for which transmission was inhibited by
exactly one collision, encountered by the Ethernet interface
in the current interval."
::= { ethIfCurrentEntry 10 }
ethIfCurrentMultipleCollisionFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of successfully
transmitted frames for which transmission was inhibited by
more than one collision, encountered by the Ethernet interface
in the current interval."
::= { ethIfCurrentEntry 11 }
ethIfCurrentDeferredTransmissions OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted frames
for which the first transmission attempt was delayed due to a
busy media, encountered by the Ethernet interface in the
current interval."
::= { ethIfCurrentEntry 12 }
ethIfCurrentLateCollisions OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of times that a
collision was detected later than the first 64 bytes of the
frame, encountered by the Ethernet interface in the current
interval."
::= { ethIfCurrentEntry 13 }
ethIfCurrentCarrierSenseErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of times that the
carrier sense condition was lost or never asserted when
attempting to transmit a frame, encountered by the Ethernet
interface in the current interval."
::= { ethIfCurrentEntry 14 }
ethIfCurrentInputCongestionDropped OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of frames dropped
due to lack of buffers in ingress pool, encountered by
the Ethernet interface in the current interval."
::= { ethIfCurrentEntry 15 }
ethIfCurrentOutputCongestionDropped OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of dropped frames
due to a congestion, encountered by the Transmit direction
to the Ethernet interface in the current interval."
::= { ethIfCurrentEntry 16 }
ethIfCurrentOverflowInFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfCurrentInFrames
counter has overflowed in the current interval."
::= { ethIfCurrentEntry 17 }
ethIfCurrentOverflowInOctets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfCurrentInOctets
counter has overflowed in the current interval."
::= { ethIfCurrentEntry 18 }
ethIfCurrentOverflowFCSErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfCurrentFCSErrors
counter has overflowed in the current interval."
::= { ethIfCurrentEntry 19 }
ethIfCurrentOverflowOutFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfCurrentOutFrames
counter has overflowed in the current interval."
::= { ethIfCurrentEntry 20 }
ethIfCurrentOverflowOutOctets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfCurrentOutOctets
counter has overflowed in the current interval."
::= { ethIfCurrentEntry 21 }
ethIfCurrentOverflowMultipleCollisionFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfCurrentMultipleCollisionFrames
counter has overflowed in the current interval."
::= { ethIfCurrentEntry 22 }
ethIfCurrentInUnicastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received Unicast frames, encountered by the
Ethernet interface in the current interval."
::= { ethIfCurrentEntry 23 }
ethIfCurrentOutUnicastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted Unicast frames, encountered by the
Ethernet interface in the current interval."
::= { ethIfCurrentEntry 24 }
ethIfCurrentInMulticastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received Multicast frames, encountered by the
Ethernet interface in the current interval."
::= { ethIfCurrentEntry 25 }
ethIfCurrentOutMulticastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted Multicast frames, encountered by the
Ethernet interface in the current interval."
::= { ethIfCurrentEntry 26 }
ethIfCurrentInBroadcastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received Broadcast frames, encountered by the
Ethernet interface in the current interval."
::= { ethIfCurrentEntry 27 }
ethIfCurrentOutBroadcastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted Broadcast frames, encountered by the
Ethernet interface in the current interval."
::= { ethIfCurrentEntry 28 }
ethIfCurrentInDiscardFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received Discarded frames, encountered by the
Ethernet interface in the current interval."
::= { ethIfCurrentEntry 29 }
ethIfCurrentOutDiscardFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted Discarded frames, encountered by the
Ethernet interface in the current interval."
::= { ethIfCurrentEntry 30 }
ethIfCurrentInPauseFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received Pause frames, encountered by the
Ethernet interface in the current interval."
::= { ethIfCurrentEntry 31 }
ethIfCurrentOutPauseFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted Pause frames, encountered by the
Ethernet interface in the current interval."
::= { ethIfCurrentEntry 32 }
ethIfCurrentOverflowInUnicastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfCurrentInUnicastFrames
counter has overflowed in the current interval."
::= { ethIfCurrentEntry 33 }
ethIfCurrentOverflowOutUnicastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfCurrentOutUnicastFrames
counter has overflowed in the current interval."
::= { ethIfCurrentEntry 34 }
ethIfCurrentOverflowInMulticastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfCurrentInMulticastFrames
counter has overflowed in the current interval."
::= { ethIfCurrentEntry 35 }
ethIfCurrentOverflowOutMulticastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfCurrentOutMulticastFrames
counter has overflowed in the current interval."
::= { ethIfCurrentEntry 36 }
ethIfCurrentOverflowInBroadcastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfCurrentInBroadcastFrames
counter has overflowed in the current interval."
::= { ethIfCurrentEntry 37 }
ethIfCurrentOverflowOutBroadcastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfCurrentOutBroadcastFrames
counter has overflowed in the current interval."
::= { ethIfCurrentEntry 38 }
ethIfCurrentOverflowInDiscardFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfCurrentInDiscardFrames
counter has overflowed in the current interval."
::= { ethIfCurrentEntry 39 }
ethIfCurrentOverflowOutDiscardFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfCurrentOutDiscardFrames
counter has overflowed in the current interval."
::= { ethIfCurrentEntry 40 }
ethIfCurrentOverflowInPauseFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfCurrentInPauseFrames
counter has overflowed in the current interval."
::= { ethIfCurrentEntry 41 }
ethIfCurrentOverflowOutPauseFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfCurrentOutPauseFrames
counter has overflowed in the current interval."
::= { ethIfCurrentEntry 42 }
--Interval Table
ethIfIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthIfIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Ethernet Interval table.
When ethIfIntervalIndex specifies the Ethernet interface (only),
the counters are for an interval of 15 minutes."
::= { ethIfPerformance 2 }
ethIfIntervalEntry OBJECT-TYPE
SYNTAX EthIfIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Ethernet Interval table."
INDEX { ethIfIntervalIndex, ethIfIntervalNumber }
::= {ethIfIntervalTable 1}
EthIfIntervalEntry ::=
SEQUENCE {
ethIfIntervalIndex
Integer32,
ethIfIntervalNumber
Integer32,
ethIfIntervalStatus
OCTET STRING,
ethIfIntervalInFrames
Gauge32,
ethIfIntervalInOctets
Gauge32,
ethIfIntervalAlignmentErrors
Gauge32,
ethIfIntervalFCSErrors
Gauge32,
ethIfIntervalLengthError
Gauge32,
ethIfIntervalOutFrames
Gauge32,
ethIfIntervalOutOctets
Gauge32,
ethIfIntervalSingleCollisionFrames
Gauge32,
ethIfIntervalMultipleCollisionFrames
Gauge32,
ethIfIntervalDeferredTransmissions
Gauge32,
ethIfIntervalLateCollisions
Gauge32,
ethIfIntervalCarrierSenseErrors
Gauge32,
ethIfIntervalInputCongestionDropped
Gauge32,
ethIfIntervalOutputCongestionDropped
Gauge32,
ethIfIntervalOverflowInFrames
Gauge32,
ethIfIntervalOverflowInOctets
Gauge32,
ethIfIntervalOverflowFCSErrors
Gauge32,
ethIfIntervalOverflowOutFrames
Gauge32,
ethIfIntervalOverflowOutOctets
Gauge32,
ethIfIntervalOverflowMultipleCollisionFrames
Gauge32,
ethIfIntervalInUnicastFrames
Gauge32,
ethIfIntervalOutUnicastFrames
Gauge32,
ethIfIntervalInMulticastFrames
Gauge32,
ethIfIntervalOutMulticastFrames
Gauge32,
ethIfIntervalInBroadcastFrames
Gauge32,
ethIfIntervalOutBroadcastFrames
Gauge32,
ethIfIntervalInDiscardFrames
Gauge32,
ethIfIntervalOutDiscardFrames
Gauge32,
ethIfIntervalInPauseFrames
Gauge32,
ethIfIntervalOutPauseFrames
Gauge32,
ethIfIntervalOverflowInUnicastFrames
Gauge32,
ethIfIntervalOverflowOutUnicastFrames
Gauge32,
ethIfIntervalOverflowInMulticastFrames
Gauge32,
ethIfIntervalOverflowOutMulticastFrames
Gauge32,
ethIfIntervalOverflowInBroadcastFrames
Gauge32,
ethIfIntervalOverflowOutBroadcastFrames
Gauge32,
ethIfIntervalOverflowInDiscardFrames
Gauge32,
ethIfIntervalOverflowOutDiscardFrames
Gauge32,
ethIfIntervalOverflowInPauseFrames
Gauge32,
ethIfIntervalOverflowOutPauseFrames
Gauge32
}
ethIfIntervalIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the Ethernet interface.
It may be ifIndex.
For some devices (e.g RICi-622GE), supporting several types of
intervals, this index will be a concatenation of the port index and
interval type.
Interval type can indicate: 1 minute, 15 minutes, 1 hour, 24 hours.
For the exact formula, see device specification."
::= { ethIfIntervalEntry 1 }
ethIfIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Interval Number. This number is between 1 and x, where 1 is the
most recently completed interval and x is the least recently
completed interval.
For 15 minute intervals, usually x=96, but it can be different,
depending on device capabilities."
::= { ethIfIntervalEntry 2 }
ethIfIntervalStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the interval:
0 - Valid.
1 - redundantLinkSwitch - the link has been switched
by a redundancy mechanism.
2 - discontinuity - module was partialy out.
4 - notValid - module is out."
::= { ethIfIntervalEntry 3 }
ethIfIntervalInFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames,
encountered by the Ethernet interface in the interval."
::= { ethIfIntervalEntry 4 }
ethIfIntervalInOctets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received octets,
encountered by the Ethernet interface in the interval."
::= { ethIfIntervalEntry 5 }
ethIfIntervalAlignmentErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames,
which are not complete (The result of dividing the number
of bits by 8 is not an Integer), encountered by the Ethernet
interface in the interval."
::= { ethIfIntervalEntry 6 }
ethIfIntervalFCSErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames
that didn't pass the FCS test, encountered by the Ethernet
interface in the interval."
::= { ethIfIntervalEntry 7 }
ethIfIntervalLengthError OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames
with length error, encountered by the Ethernet interface in
the interval."
::= { ethIfIntervalEntry 8 }
ethIfIntervalOutFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted frames,
encountered by the Ethernet interface in the interval."
::= { ethIfIntervalEntry 9 }
ethIfIntervalOutOctets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted octets,
encountered by the Ethernet interface in the interval."
::= { ethIfIntervalEntry 10 }
ethIfIntervalSingleCollisionFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of successfully
transmitted frames for which transmission was inhibited by
exactly one collision, encountered by the Ethernet
interface in the interval."
::= { ethIfIntervalEntry 11 }
ethIfIntervalMultipleCollisionFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of successfully
transmitted frames for which transmission was inhibited by
more than one collision, encountered by the Ethernet
interface in the interval."
::= { ethIfIntervalEntry 12 }
ethIfIntervalDeferredTransmissions OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted frames
for which the first transmission attempt was delayed due to a
busy media, encountered by the Ethernet interface in the interval."
::= { ethIfIntervalEntry 13 }
ethIfIntervalLateCollisions OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of times that a
collision was detected later than the first 64 bytes of the
frame, encountered by the Ethernet interface in the interval."
::= { ethIfIntervalEntry 14 }
ethIfIntervalCarrierSenseErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of times that the
carrier sense condition was lost or never asserted when
attempting to transmit a frame, encountered by the Ethernet
interface in the interval."
::= { ethIfIntervalEntry 15 }
ethIfIntervalInputCongestionDropped OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of dropped frames
due to a congestion, encountered by the Receive direction
to the Ethernet interface in the interval."
::= { ethIfIntervalEntry 16 }
ethIfIntervalOutputCongestionDropped OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of dropped frames
due to a congestion, encountered by the Transmit direction
to the Ethernet interface in the interval."
::= { ethIfIntervalEntry 17 }
ethIfIntervalOverflowInFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfIntervalInFrames
counter has overflowed in the interval."
::= { ethIfIntervalEntry 18 }
ethIfIntervalOverflowInOctets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfIntervalInOctets
counter has overflowed in the interval."
::= { ethIfIntervalEntry 19 }
ethIfIntervalOverflowFCSErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfIntervalFCSErrors
counter has overflowed in the interval."
::= { ethIfIntervalEntry 20 }
ethIfIntervalOverflowOutFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfIntervalOutFrames
counter has overflowed in the interval."
::= { ethIfIntervalEntry 21 }
ethIfIntervalOverflowOutOctets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfIntervalOutOctets
counter has overflowed in the interval."
::= { ethIfIntervalEntry 22 }
ethIfIntervalOverflowMultipleCollisionFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfIntervalMultipleCollisionFrames
counter has overflowed in the interval."
::= { ethIfIntervalEntry 23 }
ethIfIntervalInUnicastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received Unicast frames, encountered by the
Ethernet interface in the interval."
::= { ethIfIntervalEntry 24 }
ethIfIntervalOutUnicastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted Unicast frames, encountered by the
Ethernet interface in the interval."
::= { ethIfIntervalEntry 25 }
ethIfIntervalInMulticastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received Multicast frames, encountered by the
Ethernet interface in the interval."
::= { ethIfIntervalEntry 26 }
ethIfIntervalOutMulticastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted Multicast frames, encountered by the
Ethernet interface in the interval."
::= { ethIfIntervalEntry 27 }
ethIfIntervalInBroadcastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received Broadcast frames, encountered by the
Ethernet interface in the interval."
::= { ethIfIntervalEntry 28 }
ethIfIntervalOutBroadcastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted Broadcast frames, encountered by the
Ethernet interface in the interval."
::= { ethIfIntervalEntry 29 }
ethIfIntervalInDiscardFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received Discarded frames, encountered by the
Ethernet interface in the interval."
::= { ethIfIntervalEntry 30 }
ethIfIntervalOutDiscardFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted Discarded frames, encountered by the
Ethernet interface in the interval."
::= { ethIfIntervalEntry 31 }
ethIfIntervalInPauseFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received Pause frames, encountered by the
Ethernet interface in the interval."
::= { ethIfIntervalEntry 32 }
ethIfIntervalOutPauseFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted Pause frames, encountered by the
Ethernet interface in the interval."
::= { ethIfIntervalEntry 33 }
ethIfIntervalOverflowInUnicastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfIntervalInUnicastFrames
counter has overflowed in the interval."
::= { ethIfIntervalEntry 34 }
ethIfIntervalOverflowOutUnicastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfIntervalOutUnicastFrames
counter has overflowed in the interval."
::= { ethIfIntervalEntry 35 }
ethIfIntervalOverflowInMulticastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfIntervalInMulticastFrames
counter has overflowed in the interval."
::= { ethIfIntervalEntry 36 }
ethIfIntervalOverflowOutMulticastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfIntervalOutMulticastFrames
counter has overflowed in the interval."
::= { ethIfIntervalEntry 37 }
ethIfIntervalOverflowInBroadcastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfIntervalInBroadcastFrames
counter has overflowed in the interval."
::= { ethIfIntervalEntry 38 }
ethIfIntervalOverflowOutBroadcastFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfIntervalOutBroadcastFrames
counter has overflowed in the interval."
::= { ethIfIntervalEntry 39 }
ethIfIntervalOverflowInDiscardFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfIntervalInDiscardFrames
counter has overflowed in the interval."
::= { ethIfIntervalEntry 40 }
ethIfIntervalOverflowOutDiscardFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfIntervalOutDiscardFrames
counter has overflowed in the interval."
::= { ethIfIntervalEntry 41 }
ethIfIntervalOverflowInPauseFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfIntervalInPauseFrames
counter has overflowed in the interval."
::= { ethIfIntervalEntry 42 }
ethIfIntervalOverflowOutPauseFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated ethIfIntervalOutPauseFrames
counter has overflowed in the interval."
::= { ethIfIntervalEntry 43 }
ethPerformanceMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
countOK (2),
countFail (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether OK or Fail statistics will be counted."
::= {ethIfPerformance 3}
ethIfPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthIfPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Ethernet Performance table."
::= { ethIfPerformance 4}
ethIfPerfEntry OBJECT-TYPE
SYNTAX EthIfPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Ethernet Performance table."
INDEX {ethIfIdx}
::= {ethIfPerfTable 1}
EthIfPerfEntry ::=
SEQUENCE {
ethIfPerfInOkFrames
Gauge32,
ethIfPerfOutOkFrames
Gauge32,
ethIfPerfTotalCollisions
Gauge32,
ethIfPerfInOkOctets
Gauge32
}
ethIfPerfInOkFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received OK frames,
encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2)
or Reset Statistics was done."
::= { ethIfPerfEntry 1 }
ethIfPerfOutOkFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted OK frames,
encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2)
or Reset Statistics was done."
::= { ethIfPerfEntry 2 }
ethIfPerfTotalCollisions OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the total number of collisions
of any type encountered by the Ethernet interface since
ethPerformanceMode Set to countOK (2) or Reset Statistics was done"
::= { ethIfPerfEntry 3 }
ethIfPerfInOkOctets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received OK Octets,
encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2)
or Reset Statistics was done."
::= { ethIfPerfEntry 4 }
ethIfOamCfm OBJECT IDENTIFIER ::= { ethIf 3 }
ethIfOamCfmEvents OBJECT IDENTIFIER ::= { ethIfOamCfm 0 }
ethOamCfmDefectCondition NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap indicates that a MEP has a persistent defect condition."
::= { ethIfOamCfmEvents 1 }
-- ETH OAM CFM Definitions (802.1ag)
-- MEP Definition
-- ******************************************************************
-- The MEG End Point Table
-- ******************************************************************
radMepTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadMepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MEG End Point (MEP) configuration table associated with
Maitenance Entity Group (MEG) End Point.
MEP is a short name for an expanded ETH flow point that includes a compound
ETH Segment flow termination function, which marks the end point of an ETH ME,
and a compound ETH Diagnostic flow function."
::= { ethIfOamCfm 1 }
radMepEntry OBJECT-TYPE
SYNTAX RadMepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
INDEX { radOamIdx1, radOamEvcIdx, radMepIdx }
::= { radMepTable 1 }
RadMepEntry ::=
SEQUENCE {
radOamIdx1 Unsigned32,
radOamEvcIdx Unsigned32,
radMepIdx Unsigned32,
radMepRowStatus RowStatus,
radMepLocalMepId Unsigned32,
radMepRemoteMepId Unsigned32,
radMepOamMode INTEGER,
radMepContinuityVerMode INTEGER,
radMepMeLevel Unsigned32,
radMepOamDestAddrType INTEGER,
radMepOamDestMacAddr MacAddress,
radMepDefaultPriority Unsigned32,
radMepCcStatus INTEGER,
radMepOamProtocol INTEGER,
radMepMdId Unsigned32,
radMepMaFormat INTEGER,
radMepMaName OCTET STRING,
radMepSpVlanId Unsigned32,
radMepCcInterval INTEGER,
radMepTransmitLbmDestMacAddress MacAddress,
radMepTransmitLbmDestMepId Unsigned32,
radMepTransmitLbmDestIsMepId INTEGER,
radMepTransmitLbmMassages Integer32,
radMepTransmitLbmVlanPriority Unsigned32,
radMepTransmitLbmVlanDropEnable INTEGER,
radMepLbrIn Counter32,
radMepLbrInOutOfOrder Counter32,
radMepLbmOut Counter32,
radMepTransmitLtmTargetMacAddress MacAddress,
radMepTransmitLtmTargetMepId Unsigned32,
radMepTransmitLtmTargetIsMepId INTEGER,
radMepTransmitLtmTtl Unsigned32,
radMepTransmitLtmActivationCmd INTEGER
}
radOamIdx1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object may indicate the Bridge Index or Configuration index."
::= { radMepEntry 1 }
radOamEvcIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Index of the EVC (Ethernet Virtual Circuit)
that the MEP is associated to."
::= { radMepEntry 2 }
radMepIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the ID of the MEP being accessed."
::= { radMepEntry 3 }
radMepRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute allows to create/delete a row in this table."
::= {radMepEntry 4 }
radMepLocalMepId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the local MEP ID."
::= { radMepEntry 5 }
radMepRemoteMepId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This atribute is currently implemneted at radMepCcTable, that
supports multicast."
::= { radMepEntry 6 }
radMepOamMode OBJECT-TYPE
SYNTAX INTEGER
{
disabled (2),
initiate (3),
react (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object determines the OAM mode of the MEP:
disabled - no CC is initiated nor responded
initiate - the device initiates and responds to CC
react - the device does not initiate a CC, but responds to CC."
::= { radMepEntry 7 }
radMepContinuityVerMode OBJECT-TYPE
SYNTAX INTEGER
{
disabled (2),
ccBased (3),
lbBased (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object determines the OAM behavior of the MEP:
disabled - no CC is done
cc_based - CC is done based on incoming messages
lb_based - CC is done based on loopback messages."
::= { radMepEntry 8 }
radMepMeLevel OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"At any point in a network, ME Level is used to distinguish between OAM
signals belonging to different nested MEs.
Maintenance Entity Levels are defined as follows:
0,1,2 are assigned to customers
3,4 are assigned to providers
5,6,7 are assigned to operators."
::= { radMepEntry 9 }
radMepOamDestAddrType OBJECT-TYPE
SYNTAX INTEGER
{
unicast (1),
multicast (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object determines if the OAM messages are sent to user defined
unicast address, or to RAD proprietary multicast address."
::= { radMepEntry 10 }
radMepOamDestMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object determines the MAC address that OAM packets are sent to."
::= { radMepEntry 11 }
radMepDefaultPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object defines the priority of the OAM messages sent when no
service is defined on EVC. If a service is defined, the OAM messages
will get the highest service priority existing on the EVC."
::= { radMepEntry 12 }
radMepCcStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
fail (2),
ok (3),
mismerge (4),
unexpectedMep (5),
unexpectedMeLevel (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Continuity Check (CC)
status."
::= { radMepEntry 13 }
radMepOamProtocol OBJECT-TYPE
SYNTAX INTEGER
{
proprietary (1),
standard (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Determines whether to use proprietary OAM mechanism,
or to use the standard (IEEE 802.1ag, ITU-T Y.1731)."
::= { radMepEntry 14 }
radMepMdId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The index of the Maintenance Domain in the radMdTable (radMdIndex)."
::= { radMepEntry 15 }
radMepMaFormat OBJECT-TYPE
SYNTAX INTEGER
{
primaryVid (1),
charString (2),
unsignedInt16 (3),
rfc2865VpnId (4),
icc (32) -- ITU Carrier Code
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type (and thereby format) of the Maintenance Association
Name."
::= { radMepEntry 16 }
radMepMaName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..45))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Short Maintenance Association name."
::= { radMepEntry 17 }
radMepSpVlanId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The SP (Service Provider) VLAN used when sending an OAM message."
::= { radMepEntry 18 }
radMepCcInterval OBJECT-TYPE
SYNTAX INTEGER
{
intervalInvalid (0), -- No CCMs are sent (disabled)
interval300Hz (1), -- CCMs are sent every 3 1/3 milliseconds (300Hz)
interval10ms (2), -- CCMs are sent every 10 milliseconds
interval100ms (3), -- CCMs are sent every 100 milliseconds
interval1s (4), -- CCMs are sent every 1 second
interval10s (5), -- CCMs are sent every 10 seconds
interval1min (6), -- CCMs are sent every minute
interval10min (7) -- CCMs are sent every 10 minutes
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the interval at which CCMs are sent by a MEP
Valid only if radMepOamMode = initiate(4)."
::= { radMepEntry 19 }
radMepTransmitLbmDestMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Target MAC Address Field to be transmitted in the Loopback Message:
For unicast MAC Address this is the unicast destination MAC address.
For multicast MAC Address, this variable is read-only.
This address will be used if the value of
radMepTransmitLbmDestIsMepId is no (2).
802.1ag clause 12.14.7.3.2:b."
::= { radMepEntry 20 }
radMepTransmitLbmDestMepId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The MEPID of another MEP in the same MA to which the
LBM is to be sent. This address will be used if the value of
radMepTransmitLbmDestIsMepId is yes (3).
802.1ag clause 12.14.7.3.2:b."
::= { radMepEntry 21 }
radMepTransmitLbmDestIsMepId OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"yes (3) indicates that MEPID of the target MEP is used for loopback transmission.
no (2) indicates that unicast destination MAC address of the target MEP is used.
802.1ag clause 12.14.7.3.2:b."
::= { radMepEntry 22 }
radMepTransmitLbmMassages OBJECT-TYPE
SYNTAX Integer32(1..1024)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of Loopback messages to be transmitted."
::= { radMepEntry 23 }
radMepTransmitLbmVlanPriority OBJECT-TYPE
SYNTAX Unsigned32(0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The priority to be used in the VLAN tag, if present,
in the transmitted frame.
The default value is CCM priority.
802.1ag clause 12.14.7.3.2:e"
::= { radMepEntry 24 }
radMepTransmitLbmVlanDropEnable OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Drop Enable bit to be used in the VLAN tag, if present,
in the transmitted frame.
802.1ag clause 12.14.7.3.2:e"
::= { radMepEntry 25 }
radMepLbrIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of valid, in-order Loopback Replies received."
::= { radMepEntry 26 }
radMepLbrInOutOfOrder OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid, out-of-order Loopback Replies
received."
::= { radMepEntry 27 }
radMepLbmOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of Loopback Messages transmitted."
::= { radMepEntry 28 }
radMepTransmitLtmTargetMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Target MAC Address Field to be transmitted in the Link Trace Message:
A unicast destination MAC address.
This address will be used
if the value of radMepTransmitLtmTargetIsMepId is no (2).
802.1ag clause 12.14.7.4.2:c."
::= { radMepEntry 29 }
radMepTransmitLtmTargetMepId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The MEPID of another MEP in the same MA to which
LTM is to be transmitted. This address will be used
if the value of radMepTransmitLtmTargetIsMepId is yes (3).
802.1ag clause 12.14.7.4.2:c."
::= { radMepEntry 30 }
radMepTransmitLtmTargetIsMepId OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"yes (3) indicates that MEPID of the target MEP is used for Linktrace transmission.
no (2) indicates that unicast destination MAC address of the target MEP is used.
802.1ag clause 12.14.7.4.2:c."
::= { radMepEntry 31 }
radMepTransmitLtmTtl OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The LTM TTL field. Default value, if not specified, is 64.
The TTL field indicates the number of hops remaining to the LTM.
Decremented by 1 each Linktrace Responder that handles the LTM.
The value received in the LTM is returned in the LTR.
If 0 on input, the LTM is not transmitted to the next hop.
802.1ag clause 12.14.7.4.2:b and 21.8.4."
::= { radMepEntry 32 }
radMepTransmitLtmActivationCmd OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Activation command for starting Loop Trace. Set will be always
to 'on' value. After operation was finished, Agent will turn the value to 'off'."
::= { radMepEntry 33 }
-- ETH OAM Service Definition
ethOamService OBJECT IDENTIFIER ::= { ethIfOamCfm 2 }
ethOamServiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthOamServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Service configuration table associated with Services running on a MEP."
::= { ethOamService 1 }
ethOamServiceEntry OBJECT-TYPE
SYNTAX EthOamServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
INDEX { radOamIdx1, radOamEvcIdx, radMepIdx, ethOamServiceIdx }
::= { ethOamServiceTable 1 }
EthOamServiceEntry ::=
SEQUENCE {
ethOamServiceIdx Unsigned32,
ethOamServiceRowStatus RowStatus,
ethOamServicePriority Unsigned32,
ethOamServicePmEnable INTEGER,
ethOamServiceFrameLossRatioThresh Integer32,
ethOamServiceDelayThresh Integer32,
ethOamServiceDelayVarThresh Integer32,
ethOamServiceUnavailRatioThresh Integer32,
ethOamServiceTxFrames Counter32,
ethOamServiceOverflowTxFrames Counter32,
ethOamServiceFrameLoss Counter32,
ethOamServiceOverflowFrameLoss Counter32,
ethOamServiceFrameLossRatio Unsigned32,
ethOamServiceElapsedTime Counter32,
ethOamServiceUnavailSec Counter32,
ethOamServiceUnavailRatio Unsigned32,
ethOamServiceFramesAboveDelay Counter32,
ethOamServiceOverflowFramesAboveDelay Counter32,
ethOamServiceFramesAboveDelayVar Counter32,
ethOamServiceOverflowFramesAboveDelayVar Counter32,
ethOamServiceCurrentDelay Unsigned32,
ethOamServiceCurrentDelayVariation Unsigned32,
ethOamServiceResetCounters INTEGER
}
ethOamServiceIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Index of the service being accessed."
::= { ethOamServiceEntry 1 }
ethOamServiceRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute allows to create/delete a row in this table."
::= {ethOamServiceEntry 2 }
ethOamServicePriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object determines the priority of the service.
It is sent as P bits in an OAM message originated by this service."
::= { ethOamServiceEntry 3 }
ethOamServicePmEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object determines PM (Performance Monitoring)
shall be enabled or not for the service."
::= { ethOamServiceEntry 4 }
ethOamServiceFrameLossRatioThresh OBJECT-TYPE
SYNTAX Integer32 (3..10)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object determines the Frame Loss ratio threshold in exponent
of 1/10. That is, a value of 4 means that the threshold is 1E-4."
::= { ethOamServiceEntry 5 }
ethOamServiceDelayThresh OBJECT-TYPE
SYNTAX Integer32 (0..50000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object determines the delay threshold defined for this service,
in measurement unit of 0.1 msec."
::= { ethOamServiceEntry 6 }
ethOamServiceDelayVarThresh OBJECT-TYPE
SYNTAX Integer32 (0..50000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object determines the delay variation threshold defined
for this service, in measurement unit of 0.1 msec."
::= { ethOamServiceEntry 7 }
ethOamServiceUnavailRatioThresh OBJECT-TYPE
SYNTAX Integer32 (3..10)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object determines the Unavailability ratio threshold in exponent
of 1/10. That is, a value of 4 means that the threshold is 1E-4."
::= { ethOamServiceEntry 8 }
ethOamServiceTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counts the number of frames trnasmitted by since the time the service is up."
::= { ethOamServiceEntry 9 }
ethOamServiceOverflowTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated
ethOamServiceTxFrames counter has overflowed."
::= { ethOamServiceEntry 10 }
ethOamServiceFrameLoss OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counts the number of frames lost since the time the service is up."
::= { ethOamServiceEntry 11 }
ethOamServiceOverflowFrameLoss OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the associated
ethOamServiceFrameLoss counter has overflowed."
::= { ethOamServiceEntry 12 }
ethOamServiceFrameLossRatio OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the ratio of the lost frames since the time the service is up.
The value is the ratio multiplied by 1E10.
0xFFFFFFFF will be returned for ratio greater than 4/10 (40%)."
::= { ethOamServiceEntry 13 }
ethOamServiceElapsedTime OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the time elapsed in seconds since the time the service is up."
::= { ethOamServiceEntry 14 }
ethOamServiceUnavailSec OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of unavailable seconds since
the time the service is up."
::= { ethOamServiceEntry 15 }
ethOamServiceUnavailRatio OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Indicates the ratio of the unavailable seconds since the
time the service is up. The value is the ratio multiplied by 1E10.
0xFFFFFFFF will be returned for ratio greater than 4/10 (40%)."
::= { ethOamServiceEntry 16 }
ethOamServiceFramesAboveDelay OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of frames arrived with delay
greater than the delay threshold."
::= { ethOamServiceEntry 17 }
ethOamServiceOverflowFramesAboveDelay OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of times the associated
ethOamServiceFramesAboveDelay counter has overflowed."
::= { ethOamServiceEntry 18 }
ethOamServiceFramesAboveDelayVar OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of frames arrived with delay variation
greater than the delay variation threshold."
::= { ethOamServiceEntry 19 }
ethOamServiceOverflowFramesAboveDelayVar OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of times the associated
ethOamServiceFramesAboveDelayVar counter has overflowed."
::= { ethOamServiceEntry 20 }
ethOamServiceCurrentDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the last measured delay sample in msec."
::= { ethOamServiceEntry 21 }
ethOamServiceCurrentDelayVariation OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the last measured delay variation sample in msec."
::= { ethOamServiceEntry 22 }
ethOamServiceResetCounters OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Reset the running PM counters of the selected service."
::= { ethOamServiceEntry 23 }
-- Service Current Statistics table
ethOamSvcCurrentStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthOamSvcCurrentStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Service Current Statistics Table."
::= { ethOamService 2 }
ethOamSvcCurrentStatEntry OBJECT-TYPE
SYNTAX EthOamSvcCurrentStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Current Statistics per service"
INDEX { radOamIdx1, radOamEvcIdx,
radMepIdx, ethOamServiceIdx }
::= { ethOamSvcCurrentStatTable 1 }
EthOamSvcCurrentStatEntry ::=
SEQUENCE {
ethOamSvcCurrFramesAboveDelayThresh PerfCurrentCount,
ethOamSvcCurrFramesBelowDelayThresh PerfCurrentCount,
ethOamSvcCurrFramesAboveDVarThresh PerfCurrentCount,
ethOamSvcCurrFramesBelowDVarThresh PerfCurrentCount,
ethOamSvcCurrFramesTxCounter PerfCurrentCount,
ethOamSvcCurrFramesLossCounter PerfCurrentCount,
ethOamSvcCurrMinRoundTripDelay Unsigned32,
ethOamSvcCurrMaxRoundTripDelay Unsigned32,
ethOamSvcCurrAvgRoundTripDelay Unsigned32,
ethOamSvcCurrMaxRoundTripDVar Unsigned32,
ethOamSvcCurrAvgRoundTripDVar Unsigned32,
ethOamSvcCurrElapsedTime Integer32,
ethOamSvcCurrUnavailSec PerfCurrentCount
}
ethOamSvcCurrFramesAboveDelayThresh OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames that arrived in the current interval
at a delay greater than the threshold value defined for the service."
::= { ethOamSvcCurrentStatEntry 1 }
ethOamSvcCurrFramesBelowDelayThresh OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames that arrived in the current interval at a delay
lower than or equal to the threshold value defined for the service."
::= { ethOamSvcCurrentStatEntry 2 }
ethOamSvcCurrFramesAboveDVarThresh OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames that arrived in the current interval at a delay
variation greater than the threshold value defined for the service."
::= { ethOamSvcCurrentStatEntry 3 }
ethOamSvcCurrFramesBelowDVarThresh OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames that arrived in the current interval
at a delay variation lower than or equal to the
threshold value defined for the service."
::= { ethOamSvcCurrentStatEntry 4 }
ethOamSvcCurrFramesTxCounter OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of trnasmitted frames in the current interval."
::= { ethOamSvcCurrentStatEntry 5 }
ethOamSvcCurrFramesLossCounter OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of lost frames in the current interval."
::= { ethOamSvcCurrentStatEntry 6 }
ethOamSvcCurrMinRoundTripDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mininal value of round trip delay in the current interval.
Values units are of 0.1 msec."
::= { ethOamSvcCurrentStatEntry 7 }
ethOamSvcCurrMaxRoundTripDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum value of round trip delay in the current interval.
Values units are of 0.1 msec."
::= { ethOamSvcCurrentStatEntry 8 }
ethOamSvcCurrAvgRoundTripDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average round trip delay in the current interval.
Values units are of 0.1 msec."
::= { ethOamSvcCurrentStatEntry 9 }
ethOamSvcCurrMaxRoundTripDVar OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum value of round trip delay variation in the current interval.
Values units are of 0.1 msec."
::= { ethOamSvcCurrentStatEntry 10 }
ethOamSvcCurrAvgRoundTripDVar OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average round trip delay variation in the current interval.
Values units are of 0.1 msec."
::= { ethOamSvcCurrentStatEntry 11 }
ethOamSvcCurrElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since
the beginning of the current interval."
::= { ethOamSvcCurrentStatEntry 12 }
ethOamSvcCurrUnavailSec OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that the service was unavailable in the current interval."
::= { ethOamSvcCurrentStatEntry 13 }
-- ETH OAM Service Interval Statistics table contains statistics being
-- collected by each Service over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
ethOamSvcIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthOamSvcIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Service Interval Statistics Table."
::= { ethOamService 3 }
ethOamSvcIntervalEntry OBJECT-TYPE
SYNTAX EthOamSvcIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interval Statistics per service"
INDEX { radOamIdx1, radOamEvcIdx,
radMepIdx, ethOamServiceIdx, ethOamSvcIntervalNum }
::= { ethOamSvcIntervalTable 1 }
EthOamSvcIntervalEntry ::=
SEQUENCE {
ethOamSvcIntervalNum Integer32,
ethOamSvcIntervalFramesAboveDelayThresh PerfIntervalCount,
ethOamSvcIntervalFramesBelowDelayThresh PerfIntervalCount,
ethOamSvcIntervalFramesAboveDVarThresh PerfIntervalCount,
ethOamSvcIntervalFramesBelowDVarThresh PerfIntervalCount,
ethOamSvcIntervalFramesTxCounter PerfIntervalCount,
ethOamSvcIntervalFramesLossCounter PerfIntervalCount,
ethOamSvcIntervalMinRoundTripDelay Unsigned32,
ethOamSvcIntervalMaxRoundTripDelay Unsigned32,
ethOamSvcIntervalAvgRoundTripDelay Unsigned32,
ethOamSvcIntervalMaxRoundTripDVar Unsigned32,
ethOamSvcIntervalAvgRoundTripDVar Unsigned32,
ethOamSvcIntervalUnavailSec PerfIntervalCount
}
ethOamSvcIntervalNum OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Interval index, which is actualy the Interval number,
where 1 is the most recently completed 15 minute interval,
and 96 is the least recently completed 15 minutes interval
(assuming that all 96 intervals exist)."
::= { ethOamSvcIntervalEntry 1 }
ethOamSvcIntervalFramesAboveDelayThresh OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames that arrived in a delay greater than the
threshold value defined for the service in the selected interval."
::= { ethOamSvcIntervalEntry 2 }
ethOamSvcIntervalFramesBelowDelayThresh OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames that arrived in a delay lower than the
threshold value defined for the service in the selected interval."
::= { ethOamSvcIntervalEntry 3 }
ethOamSvcIntervalFramesAboveDVarThresh OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames that arrived in a delay variation greater than the
threshold value defined for the service in the selected interval."
::= { ethOamSvcIntervalEntry 4 }
ethOamSvcIntervalFramesBelowDVarThresh OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames that arrived in a delay variation lower than the
threshold value defined for the service in the selected interval."
::= { ethOamSvcIntervalEntry 5 }
ethOamSvcIntervalFramesTxCounter OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of trnasmitted frames in the selected interval."
::= { ethOamSvcIntervalEntry 6 }
ethOamSvcIntervalFramesLossCounter OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of lost frames in the selected interval."
::= { ethOamSvcIntervalEntry 7 }
ethOamSvcIntervalMinRoundTripDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mininal value of round trip delay in the selected interval.
Values units are of 0.1 msec."
::= { ethOamSvcIntervalEntry 8 }
ethOamSvcIntervalMaxRoundTripDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum value of round trip delay in the selected interval.
Values units are of 0.1 msec."
::= { ethOamSvcIntervalEntry 9 }
ethOamSvcIntervalAvgRoundTripDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average round trip delay in the selected interval.
Values units are of 0.1 msec."
::= { ethOamSvcIntervalEntry 10 }
ethOamSvcIntervalMaxRoundTripDVar OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum value of round trip delay variation in the selected interval.
Values units are of 0.1 msec."
::= { ethOamSvcIntervalEntry 11 }
ethOamSvcIntervalAvgRoundTripDVar OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average round trip delay variation in the selected interval.
Values units are of 0.1 msec."
::= { ethOamSvcIntervalEntry 12 }
ethOamSvcIntervalUnavailSec OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that the service was unavailable
in the selected interval."
::= { ethOamSvcIntervalEntry 13 }
-- ETH OAM Service Total Statistics table
ethOamSvcTotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthOamSvcTotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ETH OAM Service Total (24H) Statistics Table."
::= { ethOamService 4 }
ethOamSvcTotalEntry OBJECT-TYPE
SYNTAX EthOamSvcTotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Statistics per service"
INDEX { radOamIdx1, radOamEvcIdx,
radMepIdx, ethOamServiceIdx }
::= { ethOamSvcTotalTable 1 }
EthOamSvcTotalEntry ::=
SEQUENCE {
ethOamSvcTotalFramesAboveDelayThresh PerfTotalCount,
ethOamSvcTotalFramesBelowDelayThresh PerfTotalCount,
ethOamSvcTotalFramesAboveDVarThresh PerfTotalCount,
ethOamSvcTotalFramesBelowDVarThresh PerfTotalCount,
ethOamSvcTotalFramesTxCounter PerfTotalCount,
ethOamSvcTotalFramesLossCounter PerfTotalCount,
ethOamSvcTotalMinRoundTripDelay Unsigned32,
ethOamSvcTotalMaxRoundTripDelay Unsigned32,
ethOamSvcTotalAvgRoundTripDelay Unsigned32,
ethOamSvcTotalMaxRoundTripDVar Unsigned32,
ethOamSvcTotalAvgRoundTripDVar Unsigned32,
ethOamSvcTotalUnavailSec PerfTotalCount
}
ethOamSvcTotalFramesAboveDelayThresh OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames that arrived in a delay greater than the
threshold value defined for the service in the last 24H."
::= { ethOamSvcTotalEntry 1 }
ethOamSvcTotalFramesBelowDelayThresh OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames that arrived in a delay lower than the
threshold value defined for the service in the last 24H."
::= { ethOamSvcTotalEntry 2 }
ethOamSvcTotalFramesAboveDVarThresh OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames that arrived in a delay variation greater than the
threshold value defined for the service in the last 24H."
::= { ethOamSvcTotalEntry 3 }
ethOamSvcTotalFramesBelowDVarThresh OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames that arrived in a delay variation lower than the
threshold value defined for the service in the last 24H."
::= { ethOamSvcTotalEntry 4 }
ethOamSvcTotalFramesTxCounter OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of trnasmitted frames in the last 24H."
::= { ethOamSvcTotalEntry 5 }
ethOamSvcTotalFramesLossCounter OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of lost frames in the last 24H."
::= { ethOamSvcTotalEntry 6 }
ethOamSvcTotalMinRoundTripDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mininal value of round trip delay in the last 24H.
Values units are of 0.1 msec."
::= { ethOamSvcTotalEntry 7 }
ethOamSvcTotalMaxRoundTripDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum value of round trip delay in the last 24H.
Values units are of 0.1 msec."
::= { ethOamSvcTotalEntry 8 }
ethOamSvcTotalAvgRoundTripDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average round trip delay in the last 24H.
Values units are of 0.1 msec."
::= { ethOamSvcTotalEntry 9 }
ethOamSvcTotalMaxRoundTripDVar OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum value of round trip delay variation in the last 24H.
Values units are of 0.1 msec."
::= { ethOamSvcTotalEntry 10 }
ethOamSvcTotalAvgRoundTripDVar OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average round trip delay variation in the last 24H.
Values units are of 0.1 msec."
::= { ethOamSvcTotalEntry 11 }
ethOamSvcTotalUnavailSec OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that the service was unavailable
in the last 24H."
::= { ethOamSvcTotalEntry 12 }
-- MD (Maintenance Domain) Definition
-- ******************************************************************
-- The Maintenance Domain Table
-- ******************************************************************
radMdTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadMdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MaintenanceDomain table. Each row in the table represents
a different maintenance domain.
A Maintenance domain is described in 802.1ag (3.22) as the
network or the part of the network for which faults in
connectivity are to be managed. The boundary of a Maintenance
Domain is defined by a set of DSAPs, each of which can become
a point of connectivity to a service instance."
::= { ethIfOamCfm 3 }
radMdEntry OBJECT-TYPE
SYNTAX RadMdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Maintenance Domain table entry. This entry is not lost
upon reboot. It is backed up by stable storage"
INDEX { radMdIndex }
::= { radMdTable 1 }
RadMdEntry ::= SEQUENCE {
radMdIndex Unsigned32,
radMdFormat INTEGER,
radMdName OCTET STRING,
radMdRowStatus RowStatus
}
radMdIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index to the maintenance domain table."
::= { radMdEntry 1 }
radMdFormat OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
dnsLikeName (2),
macAddressAndUint (3),
charString (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type (and thereby format) of the Maintenance Domain Name."
::= { radMdEntry 2 }
radMdName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..43))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Maintenance Domain name. The type/format of this object
is determined by the value of the radMdNameType object.
Each Maintenance Domain has unique name amongst all those
used or available to a service provider or operator. It
facilitates easy identification of administrative
responsibility for each Maintenance Domain."
::= { radMdEntry 3 }
radMdRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute allows to create/delete a row in this table.
The writable columns in a row can not be changed if the row
is active. All columns must have a valid value before a row
can be activated."
::= { radMdEntry 4 }
-- ******************************************************************
-- The Linktrace Reply Table
-- ******************************************************************
radMepLtrTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadMepLtrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains a list of Linktrace replies
received by a specific MEP in response to
a linktrace message.
"
::= { ethIfOamCfm 4 }
radMepLtrEntry OBJECT-TYPE
SYNTAX RadMepLtrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The LinktraceReply table entry."
INDEX { radOamIdx1, radMepIdx, radMepLtrReceiveOrder }
::= { radMepLtrTable 1 }
RadMepLtrEntry ::= SEQUENCE {
radMepLtrReceiveOrder Unsigned32,
radMepLtrTtl Unsigned32,
radMepLtrMacAddr MacAddress,
radMepLtrRelay INTEGER,
radMepLtrIngress INTEGER,
radMepLtrIngressPortIdSubtype LldpPortIdSubtype,
radMepLtrIngressPortId OCTET STRING,
radMepLtrEgress INTEGER,
radMepLtrEgressPortIdSubtype LldpPortIdSubtype,
radMepLtrEgressPortId OCTET STRING
}
radMepLtrReceiveOrder OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index to distinguish among multiple LTRs with the same LTR
Transaction Identifier field value. radMepLtrReceiveOrder
are assigned sequentially from 1, in the order that the
Linktrace Initiator received the LTRs."
::= { radMepLtrEntry 1 }
radMepLtrTtl OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TTL field value for a returned LTR."
::= { radMepLtrEntry 2 }
radMepLtrMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC address in the header of the returned LTR."
::= { radMepLtrEntry 3 }
radMepLtrRelay OBJECT-TYPE
SYNTAX INTEGER
{
rlyHit (1),
rlyFdb (2),
rlyMpdb (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value returned in the Relay Action field:
rlyHit - the LTM reached an MP whose MAC address matches the target MAC address.
rlyFdb - the Egress Port was determined by consulting the Filtering Database.
rlyMpdb - the Egress Port was determined by consulting the MIP CCM Database.
802.1ag clauses 12.14.7.5.3:g and 20.36.2.5"
::= { radMepLtrEntry 4 }
radMepLtrIngress OBJECT-TYPE
SYNTAX INTEGER
{
ingNoTlv (1),
ingOk (2),
ingDown (3),
ingBlocked (4),
ingVid (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value returned in the Ingress Action Field of the LTM.
ingNoTlv - no Reply Ingress TLV was returned in the LTM.
ingOK - the target data frame would be passed through to the MAC Relay Entity.
ingDown - the Bridge Port's MAC_Operational parameter is false.
ingBlocked - the target data frame would not be forwarded if received on this port.
ingVid - the ingress port is not in the members of the LTM's VID,
and ingress filtering is enabled, so the target data frame would be
filtered by the ingress filtering.
802.1ag clauses 12.14.7.5.3:k and 20.36.2.6"
::= { radMepLtrEntry 5 }
radMepLtrIngressPortIdSubtype OBJECT-TYPE
SYNTAX LldpPortIdSubtype
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The format of the Ingress Port ID.
If the radMepLtrIngress object contains the value
egrNoTlv(1), then the contents of this object are meaningless.
802.1ag clauses 12.14.7.5.3:m and 20.36.2.8"
::= { radMepLtrEntry 6 }
radMepLtrIngressPortId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ingress Port ID. This is an alpha-numeric string that contains a
specific identifier for the port.
The format of this object is determined by
the value of the radMepLtrIngressPortIdSubtype object.
If the radMepLtrIngress object contains the value
ingNoTlv(1), then the contents of this object are meaningless.
802.1ag clauses 12.14.7.5.3:n and 20.36.2.9"
::= { radMepLtrEntry 7 }
radMepLtrEgress OBJECT-TYPE
SYNTAX INTEGER
{
egrNoTlv (1),
egrOK (2),
egrDown (3),
egrBlocked (4),
egrVid (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value returned in the Egress Action Field of the LTM.
The value egrNoTlv(1) indicates that no Reply Egress TLV was
returned in the LTM.
802.1ag clauses 12.14.7.5.3:o and 20.36.2.10"
::= { radMepLtrEntry 8 }
radMepLtrEgressPortIdSubtype OBJECT-TYPE
SYNTAX LldpPortIdSubtype
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The format of the egress Port ID.
If the radMepLtrEgress object contains the value
egrNoTlv(1), then the contents of this object are meaningless.
802.1ag clauses 12.14.7.5.3:q and 20.36.2.12"
::= { radMepLtrEntry 9 }
radMepLtrEgressPortId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Egress Port ID. The format of this object is determined by
the value of the radMepLtrEgressPortIdSubtype object.
If the radMepLtrEgress object contains the value
egrNoTlv(1), then the contents of this object are meaningless.
802.1ag clauses 12.14.7.5.3:r and 20.36.2.13"
::= { radMepLtrEntry 10 }
-- ******************************************************************
-- The MEP CC Status Table
-- ******************************************************************
radMepCcStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadMepCcStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains a list of CC Status
received by a specific MEP from different Remote MEPs.
"
::= { ethIfOamCfm 5 }
radMepCcStatusEntry OBJECT-TYPE
SYNTAX RadMepCcStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the CC Status Table."
INDEX { radOamIdx1, radMepIdx, radMepRemoteMepIdx }
::= { radMepCcStatusTable 1 }
RadMepCcStatusEntry ::= SEQUENCE {
radMepRemoteMepIdx Unsigned32,
radMepCcStatusRemMepId Unsigned32,
radMepCcStat INTEGER,
radMepCcStatusMacAddr MacAddress
}
radMepRemoteMepIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a running index for arriving CC messages (from different Remote MEPs)
for a specific MEP ID."
::= { radMepCcStatusEntry 1 }
radMepCcStatusRemMepId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute indicates the Remote MEP ID from which the CC
messages has arrived."
::= { radMepCcStatusEntry 2 }
radMepCcStat OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
fail (2),
ok (3),
mismerge (4),
unexpectedMep (5),
unexpectedMeLevel (6),
unexpectedPeriod (7),
rdi (8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Continuity Check (CC) status (ITU-T Y.1731, Appendix I):
mismerge - A MEP detects a Mismerge condition when a CCM frame arrives with the
correct MEG level, but incorrect MEG ID.
unexpectedMep -A MEP detects an Unexpected MEP condition when a CCM frame arrives with the
correct MEG level, the correct MEG ID, but an unexpected MEP ID,
which includes the MEP's own MEP ID.
unexpectedMeLevel - A MEP detects an Unexpected MEG Level condition when a CCM frame
arrives with incorrect MEG Level. Incorrect MEG Level is less than the MEP's
own MEG level.
unexpectedPeriod - A MEP detects an Unexpected Period condition when a CCM frame
arrives with a correct MEG level. a correct MEG ID, a correct MEP ID,
but with the Period field value different from the MEP's own CCM
transmission period.
rdi - A MEP detects RDI when it receives a CCM frame with the RDI field set."
::= { radMepCcStatusEntry 3 }
radMepCcStatusMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the MAC Address in the
CC Status message received."
::= { radMepCcStatusEntry 4 }
--Ethernet Type at system level
ethOamStdEtherType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Standard Ether Type in an OAM message.
This object will be RW until a formal value will be issued for standard Ethernet Type.
When such Standard will exist, this object will be supported RO to reflect
the Standard value."
::= { ethIfOamCfm 6 }
--MAC Address at system level
ethOamStdMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Standard MAC Address in an OAM message.
This object will be RW until a formal value will be issued for standard MAC Address.
When such Standard will exist, this object will be supported RO to reflect
the Standard value."
::= { ethIfOamCfm 7 }
-- ******************************************************************
-- The Extension for the Maintenance Domain Table
-- ******************************************************************
dot1agXCfmMdTable
OBJECT-TYPE
SYNTAX SEQUENCE OF Dot1agXCfmMdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Maintenance Domain table. Each row in the table represents
a different maintenance association."
::= { ethIfOamCfm 8 }
dot1agXCfmMdEntry OBJECT-TYPE
SYNTAX Dot1agXCfmMdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Maintenance Domain table entry."
-- AUGMENTS { dot1agCfmMdEntry }
INDEX { dot1agCfmMdIndex }
::= { dot1agXCfmMdTable 1 }
Dot1agXCfmMdEntry ::= SEQUENCE
{
dot1agXCfmMdProtocol INTEGER
}
dot1agXCfmMdProtocol OBJECT-TYPE
SYNTAX INTEGER
{
preStandard (1),
standard (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
."
::= { dot1agXCfmMdEntry 1 }
-- ******************************************************************
-- The Extension for the MEP Table
-- ******************************************************************
dot1agXCfmMepTable
OBJECT-TYPE
SYNTAX SEQUENCE OF Dot1agXCfmMepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Maintenance Association End Point (MEP) table."
::= { ethIfOamCfm 9 }
dot1agXCfmMepEntry OBJECT-TYPE
SYNTAX Dot1agXCfmMepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MEP table entry
"
-- AUGMENTS { dot1agCfmMepEntry }
INDEX { dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier
}
::= { dot1agXCfmMepTable 1 }
Dot1agXCfmMepEntry ::= SEQUENCE
{
dot1agXCfmMepContinuityVerMode INTEGER,
dot1agXCfmMepDestAddrType INTEGER,
dot1agXCfmMepDestMacAddr MacAddress,
dot1agXCfmMepMappingProfile Unsigned32
}
dot1agXCfmMepContinuityVerMode OBJECT-TYPE
SYNTAX INTEGER
{
disabled (2),
ccBased (3),
lbBased (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object determines the OAM behavior of the MEP:
disabled - no Continuity Verification is done
cc_based - Continuity Verification is done based on incoming CC messages
lb_based - Continuity Verification is done based on loopback messages."
::= { dot1agXCfmMepEntry 1 }
dot1agXCfmMepDestAddrType OBJECT-TYPE
SYNTAX INTEGER
{
unicast (1),
multicast (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object determines if the OAM messages are sent to user defined
unicast address, or to RAD proprietary multicast address."
::= { dot1agXCfmMepEntry 2 }
dot1agXCfmMepDestMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object determines the MAC address that OAM packets are sent to."
::= { dot1agXCfmMepEntry 3 }
dot1agXCfmMepMappingProfile OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute defines the Mapping/classification profile (flowMappingProfileTable )
assigned to this Mep."
::= { dot1agXCfmMepEntry 4}
-- ******************************************************************
-- The Extension for the MEP Database Table
-- ******************************************************************
dot1agXCfmMepDbTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot1agXCfmMepDbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MEP DB table"
::= { ethIfOamCfm 10 }
dot1agXCfmMepDbEntry OBJECT-TYPE
SYNTAX Dot1agXCfmMepDbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MEP Database table entry.
"
-- AUGMENTS dot1agCfmMepDbEntry
INDEX { dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier,
dot1agCfmMepDbRMepIdentifier
}
::= { dot1agXCfmMepDbTable 1 }
Dot1agXCfmMepDbEntry ::= SEQUENCE
{
dot1agXCfmMepCcStat INTEGER
}
dot1agXCfmMepCcStat OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
fail (2),
ok (3),
mismerge (4),
unexpectedMep (5),
unexpectedMeLevel (6),
unexpectedPeriod (7),
rdi (8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Continuity Check (CC) status (ITU-T Y.1731, Appendix I):
mismerge - A MEP detects a Mismerge condition when a CCM frame arrives with the
correct MEG level, but incorrect MEG ID.
unexpectedMep -A MEP detects an Unexpected MEP condition when a CCM frame arrives with the
correct MEG level, the correct MEG ID, but an unexpected MEP ID,
which includes the MEP's own MEP ID.
unexpectedMeLevel - A MEP detects an Unexpected MEG Level condition when a CCM frame
arrives with incorrect MEG Level. Incorrect MEG Level is less than the MEP's
own MEG level.
unexpectedPeriod - A MEP detects an Unexpected Period condition when a CCM frame
arrives with a correct MEG level. a correct MEG ID, a correct MEP ID,
but with the Period field value different from the MEP's own CCM
transmission period.
rdi - A MEP detects RDI when it receives a CCM frame with the RDI field set."
::= { dot1agXCfmMepDbEntry 1 }
-- ETH Ring Definition
ethIfRing OBJECT IDENTIFIER ::= { ethIf 4 }
ethIfRingEvents OBJECT IDENTIFIER ::= { ethIfRing 0 }
ethIfRingTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthIfRingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ethernet Ring Table."
::= { ethIfRing 1 }
ethIfRingEntry OBJECT-TYPE
SYNTAX EthIfRingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
INDEX { ethIfRingIdx }
::= { ethIfRingTable 1 }
EthIfRingEntry ::=
SEQUENCE {
ethIfRingIdx Unsigned32,
ethIfRingAdminStatus INTEGER,
ethIfRingPorts PortList,
ethIfRingOperStatus INTEGER,
ethIfRingKeepAliveInterval Unsigned32,
ethIfRingKeepAliveThresh Unsigned32,
ethIfRingKeepAliveVlanId Unsigned32,
ethIfRingMultiCastVlanId Unsigned32,
ethIfRingRowStatus INTEGER
}
ethIfRingIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is an Index that can indicate
Slot, Ring, Cnfg etc., according to the device used.
When NA, 1 will be used."
::= { ethIfRingEntry 1 }
ethIfRingAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
down (2),
up (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object denotes the Ethernet Ring administrative status."
::= { ethIfRingEntry 2 }
ethIfRingPorts OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The set of ports which are assigned to be ring members.
The default value of this object is a string of zeros."
::= {ethIfRingEntry 3}
ethIfRingOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
open (2),
close (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Ethernet Ring operational status."
::= { ethIfRingEntry 4 }
ethIfRingKeepAliveInterval OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the period of time (in msec.)
between two consequent Keep Alive messages."
::= { ethIfRingEntry 5 }
ethIfRingKeepAliveThresh OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the maximum number of
missed Keep Alive answer messages acceptable, after which link status will be failed."
::= { ethIfRingEntry 6 }
ethIfRingKeepAliveVlanId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Dedicated VLAN ID for keep alive messages."
::= { ethIfRingEntry 7 }
ethIfRingMultiCastVlanId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Dedicated VLAN ID for multicast messages."
::= { ethIfRingEntry 8 }
ethIfRingRowStatus OBJECT-TYPE
SYNTAX INTEGER
{
active(1),
createAndGo(4),
destroy(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Implement creation/deletion of rings in the device."
::= { ethIfRingEntry 9 }
--ETH RING NOTIFICATIONS
ethIfRingStatusChange NOTIFICATION-TYPE
OBJECTS {ethIfRingOperStatus}
STATUS current
DESCRIPTION
"This trap indicates that the status of the
Ethernet Ring has been changed."
::= { ethIfRingEvents 1 }
-- ETH Storming
ethIfStorming OBJECT IDENTIFIER ::= { ethIf 5 }
ethIfStormTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthIfStormEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ethernet Storming Table."
::= { ethIfStorming 1 }
ethIfStormEntry OBJECT-TYPE
SYNTAX EthIfStormEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
INDEX {ethIfStormCnfgIdx, ethIfStormIfIdx, ethIfStormDirection, ethIfStormPacketType }
::= { ethIfStormTable 1 }
EthIfStormEntry ::=
SEQUENCE {
ethIfStormCnfgIdx Unsigned32,
ethIfStormIfIdx Unsigned32,
ethIfStormDirection INTEGER,
ethIfStormPacketType BITS,
ethIfStormCtrlEnable INTEGER,
ethIfStormMaxRate Unsigned32
}
ethIfStormCnfgIdx OBJECT-TYPE
SYNTAX Unsigned32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg(1..255) being
accessed ; Idx of 255 relates to the TmpCnfg."
::= {ethIfStormEntry 1}
ethIfStormIfIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique index of the ethernet interface/port."
::= {ethIfStormEntry 2}
ethIfStormDirection OBJECT-TYPE
SYNTAX INTEGER {
all (1),
ingress (2),
egress (3)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the port's Storm Direction."
::= { ethIfStormEntry 3 }
ethIfStormPacketType OBJECT-TYPE
SYNTAX BITS
{
unknownUnicast (0), --Flooded Unicast
broadcast (1),
multicast (2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Packet Type on which Storming operations will be performed."
::= { ethIfStormEntry 4 }
ethIfStormCtrlEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if the Storm Controling is Enabled or Disabled
for the relevant entry."
::= { ethIfStormEntry 5 }
ethIfStormMaxRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Maximum Rate at which Storming packets are forwarded,
in Kbps.For some devices the units are PPS(Packets Per Second ) or kilobytes
per second."
::= { ethIfStormEntry 6 }
ethIfOamEfm OBJECT IDENTIFIER ::= { ethIf 6 }
-- ETH OAM EFM: 802.3ah
dot3OamEvents OBJECT IDENTIFIER ::= { ethIfOamEfm 0 }
dot3OamOperStatusChange NOTIFICATION-TYPE
OBJECTS { dot3OamOperStatus }
STATUS current
DESCRIPTION
"This trap is sent when OAM EFM Link goes Up or Down.
Up - is considered when dot3OamOperStatus value changes to operational(9)
from any other value.
Down - is considered when dot3OamOperStatus value changes from operational(9)
to any other value."
::= { dot3OamEvents 1 }
dot3OamPeerEvent NOTIFICATION-TYPE
OBJECTS { dot3OamXPeerState }
STATUS current
DESCRIPTION
"This trap is sent when value of dot3OamXPeerState changes from any value
to one of the following values: linkFault, dyingGasp, criticalEvent.
This trap has no recovery (clearing value)."
::= { dot3OamEvents 2 }
dot3OamDescrTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot3OamDescrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table supports definitions of Descriptors (profiles) of OAM EFM Links."
::= {ethIfOamEfm 1}
dot3OamDescrEntry OBJECT-TYPE
SYNTAX Dot3OamDescrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry corresponds to a single OAM EFM Descriptor (profile).
Each Descriptor contains a set of OAM EFM Link configuration
parameters. The configuration parameters are applied to the
OAM EFM Links referencing this Descriptor (see dot3OamXDescrId
object). Descriptors may be created/deleted using the row creation/deletion
mechanism via dot3OamDescrRowStatus. If an active entry is referenced
in dot3OamXDescrId, the entry MUST remain active until all references are removed."
INDEX { dot3OamDescrId }
::= { dot3OamDescrTable 1 }
Dot3OamDescrEntry ::=
SEQUENCE {
dot3OamDescrId Unsigned32,
dot3OamDescrRowStatus RowStatus,
dot3OamDescrMode INTEGER,
dot3OamDescrLbRxOperation INTEGER,
dot3OamDescrRateLimit Unsigned32
}
dot3OamDescrId OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is the unique index associated with this Descriptor (profile).
Entries in this table are referenced via the object dot3OamXDescrId
in dot3OamXEntry."
::= { dot3OamDescrEntry 1 }
dot3OamDescrRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls creation/deletion of the associated entry in this table
per the semantics of RowStatus. If an active entry is referenced in
dot3OamXDescrId, the entry MUST remain active until all references are removed."
::= { dot3OamDescrEntry 2 }
dot3OamDescrMode OBJECT-TYPE
SYNTAX INTEGER {
passive(1),
active (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls the mode of OAM operation for an Ethernet-like interface
referencing this Descriptor.
OAM on Ethernet interfaces may be in 'active' mode or 'passive' mode.
These two modes differ in that active mode provides additional capabilities
to initiate monitoring activities with the remote OAM peer entity, while
passive mode generally waits for the peer to initiate OAM actions with it.
As an example, an active OAM entity can put the remote OAM entity in a
loopback state, where a passive OAM entity cannot."
::= { dot3OamDescrEntry 3 }
dot3OamDescrLbRxOperation OBJECT-TYPE
SYNTAX INTEGER {
ignore(1),
process(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Since OAM loopback is a disruptive operation (user traffic does not pass),
this object provides a mechanism to provide control: whether received OAM
loopback commands are processed or ignored, for the OAM Link referencing
this Descriptor.
When the value is ignore(1), received loopback commands are ignored.
When the value is process(2), received loopback commands are processed.
The default value is to ignore loopback commands (ignore(1))."
::= { dot3OamDescrEntry 4 }
dot3OamDescrRateLimit OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object defines how many OAM frames can be sent per second (maximum)
for an OAM EFM Link referencing this Descriptor."
::= { dot3OamDescrEntry 5 }
dot3OamXTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot3OamXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of dot3OamTable of standard DOT3-OAM-MIB."
::= { ethIfOamEfm 2 }
dot3OamXEntry OBJECT-TYPE
SYNTAX Dot3OamXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in dot3OamXTable."
AUGMENTS { dot3OamEntry }
::= { dot3OamXTable 1 }
Dot3OamXEntry ::=
SEQUENCE {
dot3OamXDescrId Unsigned32,
dot3OamXPeerState INTEGER
}
dot3OamXDescrId OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object points to an entry of dot3OamDescrTable (dot3OamDescrId),
which defines part of the configuration parameters for this OAM EFM Link.
As long as one of the OAM EFM Links refers an entry in the dot3OamDescrTable,
this entry cannot be removed.
When an OAM EFM Link supports this object (RW), the standard MIB objects of:
dot3OamMode (parallel to dot3OamDescrMode) and dot3OamLoopbackIgnoreRx
(parallel to dot3OamDescrLbRxOperation) will be supported by Agent RO."
::= { dot3OamXEntry 1 }
dot3OamXPeerState OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
operational (2),
linkFault (3),
dyingGasp (4),
criticalEvent(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reports the state of the Peer of the OAM EFM Link.
unknown - at the initialization of the device, or after Reset, when
there is still no data about the peer's state.
operational - usually after unknown state, when device senses that
peer is OK.
linkFault - Loss of Signal is detected by the receiver.
dyingGasp - Unrecoverable condition has occurred (e.g power failure)
criticalEvent - Unspecified Critical Event has occured."
::= { dot3OamXEntry 2 }
ethIfMacLayer OBJECT IDENTIFIER ::= {ethIf 7}
ethIfMacLayerEvents OBJECT IDENTIFIER ::= { ethIfMacLayer 0 }
ethIfSrcMacCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthIfSrcMacCtrlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table supports source MAC addresses control parameters per interface.
Source MAC control will be used mainly for security. Only packets with certain source MAC
Addresses will be allowed to access the device. The source MAC addresses can be static or learned.
The static addresses will be defined by the user in another table: ethIfSrcMacCtrlAddrTable.
The learned addresses will exist in the ethIfSrcMacCtrlAddrTable as well."
::= {ethIfMacLayer 1}
ethIfSrcMacCtrlEntry OBJECT-TYPE
SYNTAX EthIfSrcMacCtrlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
INDEX { ethIfSrcMacCtrlIndex, ethIfSrcMacCtrlIdx2 }
::= { ethIfSrcMacCtrlTable 1 }
EthIfSrcMacCtrlEntry ::=
SEQUENCE {
ethIfSrcMacCtrlIndex Unsigned32,
ethIfSrcMacCtrlIdx2 Unsigned32,
ethIfSrcMacCtrl INTEGER,
ethIfSrcMacCtrlMaxPermitAddr Unsigned32,
ethIfSrcMacCtrlCurNumPermitAddr Unsigned32,
ethIfSrcMacCtrlFlushAddrCmd INTEGER,
ethIfSrcMacCtrlAging Unsigned32,
ethIfSrcMacCtrlLocking INTEGER,
ethIfSrcMacCtrlViolationAction INTEGER,
ethIfSrcMacCtrlLastViolatingAddr MacAddress,
ethIfSrcMacCtrlPortStatus INTEGER
}
ethIfSrcMacCtrlIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the MAC Layer interface supporting source MAC control feature.
It may be the ifIndex of the ETH/Bridge Port."
::= { ethIfSrcMacCtrlEntry 1 }
ethIfSrcMacCtrlIdx2 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A second index that can be used. For example: The VLAN ID for which the source MAC
control feature is supported. When this index is not in use, its value will be: 9999."
::= { ethIfSrcMacCtrlEntry 2 }
ethIfSrcMacCtrl OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable the source MAC control on the current interface.
The device should not enable source MAC control if for the current interface there
are more than ethIfSrcMacCtrlMaxPermitAddr addresses in the ethIfSrcMacCtrlAddrTable.
Default value will be: disable (2)."
::= { ethIfSrcMacCtrlEntry 3 }
ethIfSrcMacCtrlMaxPermitAddr OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the maximum number of permitted MAC addresses (static and learned) for the
current interface."
::= { ethIfSrcMacCtrlEntry 4 }
ethIfSrcMacCtrlCurNumPermitAddr OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the number of source MAC addresses currently permitted for the
current interface."
::= { ethIfSrcMacCtrlEntry 5 }
ethIfSrcMacCtrlFlushAddrCmd OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to on (3) this command will erase all the learned addresses and invalid
addresses of the selected interface in the ethIfSrcMacCtrlAddrTable.
After operation is finished, Agent will turn the value to 'off'."
::= { ethIfSrcMacCtrlEntry 6 }
ethIfSrcMacCtrlAging OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The timeout period in seconds for aging out dynamically learned source MAC addresses.
Valid Values:
0 - disable
10-1000000"
::= { ethIfSrcMacCtrlEntry 7 }
ethIfSrcMacCtrlLocking OBJECT-TYPE
SYNTAX INTEGER
{
unlock (2),
lock (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to lock (3) this command will lock the Source MAC Address learning.
No more learned addresses will be added to the ethIfSrcMacCtrlAddrTable.
When set to unlock (2) this command will unlock the Source MAC Address learning.
Learned addresses will be added to the ethIfSrcMacCtrlAddrTable but the number of
addresses in the table will not exceed ethIfSrcMacCtrlMaxPermitAddr.
Default value is: unlock (2)."
::= { ethIfSrcMacCtrlEntry 8 }
ethIfSrcMacCtrlViolationAction OBJECT-TYPE
SYNTAX INTEGER
{
drop (2),
dropNotify (3),
shutdown (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines the action that the device will take upon security violation.
drop(2) - the violating packets will be dropped.
dropNotify (3)- the violating packets will be dropped and notifications
will be generated. Notifications may be for example:
SNMP Traps, Syslog messages and log file new entries.
shutdown (4) - the interface will be forced to shut down."
::= { ethIfSrcMacCtrlEntry 9 }
ethIfSrcMacCtrlLastViolatingAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the last MAC address that violated the security
on the current interface. If no violation, the agent will return:
00-00-00-00-00-00 ."
::= { ethIfSrcMacCtrlEntry 10 }
ethIfSrcMacCtrlPortStatus OBJECT-TYPE
SYNTAX INTEGER
{
shutdown (2),
secureActive (3),
secureInactive (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the operational status of the MAC Control feature
on an interface.
shutdown(2) - This indicates that the port is shutdown due to security
violation.
secureActive (3) - This indicates that the MAC Control interface security
is operational and this interface is not shutdown due to
security violation.
secureInactive (4)- This indicates that the MAC Control is not operational."
::= { ethIfSrcMacCtrlEntry 11 }
ethIfSrcMacCtrlAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthIfSrcMacCtrlAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table shows which MAC Addresses are permitted when the source MAC control
is enabled and which non permitted MAC Addresses attempted to access the
current interface. It contains static source MAC Addresses as well as learned
MAC Addresses. The user can configure Static permitted source MAC Addresses via this table."
::= {ethIfMacLayer 2}
ethIfSrcMacCtrlAddrEntry OBJECT-TYPE
SYNTAX EthIfSrcMacCtrlAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
INDEX {ethIfSrcMacCtrlAddrIndex, ethIfSrcMacCtrlAddr, ethIfSrcMacCtrlAddrIdx3 }
::= { ethIfSrcMacCtrlAddrTable 1 }
EthIfSrcMacCtrlAddrEntry ::=
SEQUENCE {
ethIfSrcMacCtrlAddrIndex Unsigned32,
ethIfSrcMacCtrlAddr MacAddress,
ethIfSrcMacCtrlAddrIdx3 Unsigned32,
ethIfSrcMacCtrlAddrRowStatus INTEGER,
ethIfSrcMacCtrlAddrStatus INTEGER
}
ethIfSrcMacCtrlAddrIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the interface for which the source MAC addresses exist in this table.
It may be the ifIndex of the ETH/Bridge Port."
::= { ethIfSrcMacCtrlAddrEntry 1 }
ethIfSrcMacCtrlAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unicast source MAC address that was learned or statically configured for the current
interface. Packets with this source MAC address will be accepted by the device."
::= { ethIfSrcMacCtrlAddrEntry 2 }
ethIfSrcMacCtrlAddrIdx3 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A third index that can be used. For example: The VLAN ID for which the source MAC control
feature is supported. When this index is not in use, its value will be: 9999."
::= { ethIfSrcMacCtrlAddrEntry 3 }
ethIfSrcMacCtrlAddrRowStatus OBJECT-TYPE
SYNTAX INTEGER
{ active (1),
createAndGo (4),
destroy (6) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB object will be used in order to create/delete a static row
or delete an address that is not allowed to access the current interface
(ethIfSrcMacCtrlAddrStatus= invalid(2)).
Device will add the learned addresses to this table.
It will not be possible to add a new static entry to this table while the
number of existing rows is equal or more than ethIfSrcMacCtrlMaxPermitAddr.
When ethIfSrcMacCtrl = enabled (3), the device will add learned entries only
up to ethIfSrcMacCtrlMaxPermitAddr."
::= { ethIfSrcMacCtrlAddrEntry 4 }
ethIfSrcMacCtrlAddrStatus OBJECT-TYPE
SYNTAX INTEGER
{
invalid (2),
learned(3),
mgmt(5) -- static
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of this entry. The meanings of the values are:
invalid (2) - the current address is not allowed to access this interface.
learned(3) - the current address was learned.
mgmt (5) - the current address is static. It may exist in the MAC Table."
::= { ethIfSrcMacCtrlAddrEntry 5 }
-- ethIfMacLayerNotifications
ethIfMacAccessViolation NOTIFICATION-TYPE
OBJECTS {ifDescr, ethIfSrcMacCtrlLastViolatingAddr}
STATUS current
DESCRIPTION
"This trap indicates that an Access Violation occurred."
::= { ethIfMacLayerEvents 1 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\tsa.txt
--
--Title: RAD's WAN TSA (Time-Slot Assignment) MIB
--By: Smadar Tauber
--Date : 30.11.1998
--Last Update: 28/11/04
--By: Smadar Tauber
--File: v:\doc\rdv\mib\ver525\tsa.txt
--***********************************************************************
--Products that use this file WITHOUT the MPMX.TXT file,have to add the
--following definitions to their *.pkb files:
--
--wanGen OBJECT IDENTIFIER ::= {radWan 1}
--agnWanGen OBJECT IDENTIFIER ::= {wanGen 2}
--agnSystemTs OBJECT IDENTIFIER ::= {agnWanGen 11}
--***********************************************************************
--
-- TS Assignment Table from system point of view
--
agnTsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnTsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { agnSystemTs 1}
agnTsEntry OBJECT-TYPE
SYNTAX AgnTsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnTsCnfgIdx, agnTsSltIdx, agnTsPrtIdx, agnTsIdx,
agnTsBitIdx, agnTsConSltIdx, agnTsConPrtIdx, agnTsConIdx }
::= { agnTsTable 1}
AgnTsEntry ::=
SEQUENCE {
agnTsCnfgIdx Integer32,
agnTsSltIdx INTEGER,
agnTsPrtIdx Integer32,
agnTsIdx Integer32,
agnTsBitIdx Integer32,
agnTsConSltIdx INTEGER,
agnTsConPrtIdx Integer32,
agnTsConIdx Integer32,
agnTsType INTEGER,
agnTsRowStatus RowStatus,
agnTsDirection INTEGER
}
agnTsCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { agnTsEntry 1}
agnTsSltIdx OBJECT-TYPE
SYNTAX INTEGER
{ clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted."
::= { agnTsEntry 2}
agnTsPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique external or internal port number.
For MP-2100, the valid values will be (for MLs only):
- exPrt1(1)..exPrt8(8)
- inPrt1(101)..inPrt8(108).
For other products' index see their specification."
::= { agnTsEntry 3}
agnTsIdx OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique index for TS (Time-Slot).
- for T1 ports - 1..24, Fbit(25)
- for E1 ports - 1..31
- for HDSL ports - 1..32 ; 32 will represent TS0."
::= { agnTsEntry 4}
agnTsBitIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique index for the Bit
of each TS (Time-Slot).
1..8 - Bit 1.. Bit 8
255 - notApplicable
This object is applicable only in Split Time-Slot cases."
::= { agnTsEntry 5}
agnTsConSltIdx OBJECT-TYPE
SYNTAX INTEGER
{ clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position In the Mux
where the TS is routed to."
::= { agnTsEntry 6}
agnTsConPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port id the TS is
routed to.
notApplicable - when agnTsType=mng or spare
For MP-2100/2200:
exPrt1 (1) .. exPrt16 (16) , notApplicable(100),
inPrt1 (101) .. inPrt48 (148).
For other products' index see their specification. "
::= { agnTsEntry 7}
agnTsConIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique TS number the Src TS is
routed to.
Valid values:
- for T1 ports - 1..24, Fbit(25)
- for E1 ports - 1..31
- for HDSL ports - 1..32 ; 32 will represent TS0.
- notApplicable - 255 (for ports that don't have TSs)."
::= { agnTsEntry 8}
agnTsType OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
voice (2),
data (3),
vcMP (4),
mng (6),
spare (7),
reserved (8),
dChannel (9)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Time-Slot Type - regarding its connection and media type.
voice, data, vcMP - connected and the media is specified.
mng - management. This TS is Dedicated to Management (not
disconnected, but not connected to another port).
spare - applicable for ML-20, ML-20N and MSL cards only.
These TSs should be reserved for future connection,
though at the moment are not connected.
reserved - these TSs are not connected, but they are Reserved for
Protection (back-up) of a certain Path. Therefore, should
NOT be used for connection of other Paths.
dChannel - is used only when the TS is connected to a V5.1 ML (Bypass)
and it contains ISDN D Channel data. In this case,
agnTsConSltIdx, agnTsConPrtIdx and agnTsConIdx, will
be 'notApplicable', since no TS is assigned for D Ch in V5.1 ML."
::= { agnTsEntry 9}
agnTsRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute allows to create/delete a row in this table.
For creating a row, the NMS should set
agnTsRowStatus.255.id2.id3.id4.id5.id6.id7.id8 = active(1).
For destroying a row, the NMS should set:
agnTsRowStatus.255.id2.id3.id4.id5.id6.id7.id8 = destroy(6).
Only rows with status active(1) are relevant.
The only possible supported RowStatus values are
active (1) and destroy (6)."
::= { agnTsEntry 10}
agnTsDirection OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
rx (2),
tx (3),
both (4),
bcastSrc (5),
bcastDst (6),
internal (7)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Direction of the connection. This parameter is especially important
when in MP a Selected Port is connected to a Connected Port that has
no TSs, so it doesn't appear in the TS Assignment for the first 5 indexes.
notApplicable - for products that do not support this object or for
certain TS Types (for example: mng, spare)
rx - the Selected Port only Receives from the Connected Port (the Selected Port
will appear in the first 5 indexes).
tx - the Selected Port only Transmits to the Connected Port (the Selected Port
will appear in the first 5 indexes). Nothing is received back.
both - the Selected Port Receives and Transmits to the Connected Port
(the Selected Port will appear in the first 5 indexes).
bcastSrc - the ML is a Broadcast-Bidirectional Source. It Transmits to
one or several IO Ports (including the one that appears in the last
3 indexes) and sometimes receives.
The Port that responds is dynamic (it can be another each time).
The ML will appear in the first 5 indexes.
bcastDst - the ML is a Broadcast-Bidirectional Destination. Therefore,
it Receives and sometimes Transmits. The ML will appear in the
first 5 indexes.
internal - for connection of TSs internally, within the same card. Such an
assignment has no effect on the external TS connections of the same
TS. A TS can be connected with 'internal' direction to a port
of the same card and at the same time, connected by another direction
to ports (and TSs) of other cards."
::= { agnTsEntry 11}
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\sps5.txt
--
-- Title: PS MIB
--
--
-- Version: 1.0
-- Date: February 1, 95
-- By: Debby Koren
-- Updated: Orly Nicklass, Smadar Tauber, Yair Arian, Liora Gafni
-- Last update: 19-Sep-06
-- By: Ilana Schvetz
-- Comments: This is the Packet Switching branch in the RAD MIB
-- X121Address ::= OCTET STRING (SIZE(0..17))
-- 0 to 17 bytes in length containing the ASCII
-- characters [0-9], each octet contains one digit
-- of the address.
-- radPS OBJECT IDENTIFIER ::= { rad 8 }
-- The groups in this MIB are the PS System Group, the Async Group, the Link Table, X.25 Group,
-- HDLC Table, STM Table. Whenever an object appears twice with only the final
-- character in the object name differing, the object whose name ends with S is read-write, and represents
-- a scratch value that will take effect upon an activate imperitive action. The object whose name ends
-- with A represents the current active value and is read-only. This was done to protect the user against
-- inadvertantly disturbing active communications and to allow switchover to a different set of parameters
-- in real time.
-- The PS System Group contains all the PS system wide cofiguration parameters
-- and the Routing Table
pktSwchSystem OBJECT IDENTIFIER ::= { radPS 1}
pktSwchSysParam OBJECT IDENTIFIER ::= { pktSwchSystem 1 }
pktSwchSysSParam OBJECT IDENTIFIER ::= { pktSwchSysParam 1 }
pktSwchSysX28PromptS OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This specifies a different PAD prompt, instead of the standard default character, the *.
Up to 10 characters can be entered."
::= { pktSwchSysSParam 1 }
pktSwchSysHeraldS OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This specifies the PAD herald message for the SPS-6 and SPS-12. Up to 32 characters
can be entered. Other devices will return a zero length octet string and will send an error
if this object is set to a string of any other length."
::= { pktSwchSysSParam 2 }
pktSwchSysBulletinS OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This specifies the PAD bulletin message. Up to 32 characters can be entered."
::= { pktSwchSysSParam 3 }
pktSwchSysComPortSubAddS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the scratch command port with the desired subaddress."
::= { pktSwchSysSParam 4 }
pktSwchSysComPortAltSubAddS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This configures the command port with the second subaddress."
::= { pktSwchSysSParam 5 }
pktSwchSysInnerCommLenS OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This specifies the address length in digits for Inner Communication."
::= { pktSwchSysSParam 6 }
pktSwchSysXOnCharS OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ASCII code of the software flow control character that will be used to start/renew the data
transfer."
::= { pktSwchSysSParam 7 }
pktSwchSysXOffCharS OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ASCII code of the software flow control character that will be used to stop the data
transfer."
::= { pktSwchSysSParam 8 }
pktSwchSysMaxLcnS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of LCNs on the device."
::= { pktSwchSysSParam 9 }
pktSwchSysMaxAIDS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of AIDs on the device."
::= { pktSwchSysSParam 10 }
pktSwchSysDeviceIdS OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The device Id."
::= { pktSwchSysSParam 11 }
pktSwchSysDtrPollPeriodS OBJECT-TYPE
SYNTAX Integer32 (300..20000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Polling interval for DTR signal, in miliseconds. DTR signal
may be used as trigger for opening and closing calls.
The value should be Set in steps of 50 msec, else it will be
rounded to the nearest 50 msec multiple (e.g 380 will be rounded to 400).
Default value: 3000 msec."
::= { pktSwchSysSParam 12 }
pktSwchSysAParam OBJECT IDENTIFIER ::= { pktSwchSysParam 2 }
pktSwchSysX28PromptA OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This specifies the active PAD prompt."
::= { pktSwchSysAParam 1 }
pktSwchSysHeraldA OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This specifies the active PAD herald message for the SPS-6 and SPS-12. Other devices will
return a zero length string."
::= { pktSwchSysAParam 2 }
pktSwchSysBulletinA OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This indicates the active PAD bulletin message."
::= { pktSwchSysAParam 3 }
pktSwchSysComPortSubAddA OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the active command port with the desired subaddress."
::= { pktSwchSysAParam 4 }
pktSwchSysComPortAltSubAddA OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the active command port with the second subaddress."
::= { pktSwchSysAParam 5 }
pktSwchSysInnerCommLenA OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This specifies the active address length in digits for Inner Communication."
::= { pktSwchSysAParam 6 }
pktSwchSysXOnCharA OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The activeASCII code of the software flow control character that is used to start/renew the data
transfer."
::= { pktSwchSysAParam 7 }
pktSwchSysXOffCharA OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The active ASCII code of the software flow control character that is used to stop the data
transfer."
::= { pktSwchSysAParam 8 }
pktSwchSysMaxLcnA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The active maximum number of LCNs on the device."
::= { pktSwchSysAParam 9 }
pktSwchSysMaxAIDA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The active maximum number of AIDs on the device."
::= { pktSwchSysAParam 10 }
pktSwchSysDeviceIdA OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The device Id."
::= { pktSwchSysAParam 11 }
pktSwchSysDtrPollPeriodA OBJECT-TYPE
SYNTAX Integer32 (300..20000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Polling interval for DTR signal, in miliseconds. DTR signal
may be used as trigger for opening and closing calls.
The value is in steps of 50 msec; if user sets it differently, it is
rounded to the nearest 50 msec multiple (e.g 380 will be rounded to 400).
Default value: 3000 msec."
::= { pktSwchSysAParam 12 }
pktSwchSysEvRepS OBJECT IDENTIFIER ::= { pktSwchSysParam 3 }
pktSwchSysEvRepAdd1S OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This specifies the X.25 address to which the reports selected by means of
pktSwchSysEvRepMask1S and pktSwchSysEvRepPeriod1S will be sent."
::= { pktSwchSysEvRepS 1 }
pktSwchSysEvRepAdd2S OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This specifies the X.25 address to which the reports selected by means of
pktSwchSysEvRepMask2S and pktSwchSysEvRepPeriod2S will be sent."
::= { pktSwchSysEvRepS 2 }
pktSwchSysEvRepMask1S OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This specifies the conditions on which reports are sent to the address specified in
pktSwchSysEvRepAdd1S. The value is a sum of values (powers of two), where each
value in the sum represents a condition. The values that may be included in the sum and
their meanings are:
0 Disable event reports
1 Send report when SYNC status has changed
2 Send report when RTS status has changed
4 Send report at Power On (Reset)
8 Report charging information at CLR."
::= { pktSwchSysEvRepS 3 }
pktSwchSysEvRepPeriod1S OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This specifies the time interval in minutes at which periodic
reports are sent to the address specified in pktSwchSysEvRepAdd1S. A value of
zero indicates that periodic reports are disabled." ::= {
pktSwchSysEvRepS 4 }
pktSwchSysEvRepMask2S OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This specifies the conditions on which reports are sent to the address specified in
pktSwchSysEvRepAdd2S. The value is a sum of values (powers of two), where each
value in the sum represents a condition. The values that may be included in the sum and
their meanings are:
0 Disable event reports
1 Send report when SYNC status has changed
2 Send report when RTS status has changed
4 Send report at Power On (Reset)
8 Report charging information at CLR."
::= { pktSwchSysEvRepS 5 }
pktSwchSysEvRepPeriod2S OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This specifies the time interval in minutes at which periodic reports are sent to
the address specified in pktSwchSysEvRepAdd2S. A value of zero indicates that
periodic reports are disabled."
::= { pktSwchSysEvRepS 6 }
pktSwchSysEvRepRetryCntS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of retries to send Event Reports to each port.
Possible values:
0 - Disable retry mechanism
1-255 - Number of retries "
::= { pktSwchSysEvRepS 7 }
pktSwchSysEvRepRetryDelayS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time interval between retries (in minutes).
Valid values: 1-255 "
::= { pktSwchSysEvRepS 8 }
pktSwchSysEvRepRetryOptionsS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Event report options. The value is a sum of values (powers of
two), where each value in the sum represents an option. The
values that may be included in the sum and their meanings are:
0 - No Options
1 - Alternate Mode: Port 1 reports are readdressed to Port 2
on failure. (Port 2 mask is not used).
2 - Condensed Format
X - Any combination of the above values "
::= { pktSwchSysEvRepS 9 }
pktSwchSysEvRepA OBJECT IDENTIFIER ::= { pktSwchSysParam 4 }
pktSwchSysEvRepAdd1A OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This specifies the active X.25 address to which the reports selected by means of
pktSwchSysEvRepMask1A and pktSwchSysEvRepPeriod1A will be sent."
::= { pktSwchSysEvRepA 1 }
pktSwchSysEvRepAdd2A OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This specifies the active X.25 address to which the reports selected by means of
pktSwchSysEvRepMask2A and pktSwchSysEvRepPeriod2A will be sent."
::= { pktSwchSysEvRepA 2 }
pktSwchSysEvRepMask1A OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This specifies the active conditions on which reports are sent to the address specified in
pktSwchSysEvRepAdd1A. The value is a sum of values (powers of two), where each
value in the sum represents a condition. The values that may be included in the sum and
their meanings are:
0 Disable event reports
1 Send report when SYNC status has changed
2 Send report when RTS status has changed
4 Send report at Power On (Reset)
8 Report charging information at CLR."
::= { pktSwchSysEvRepA 3 }
pktSwchSysEvRepPeriod1A OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This specifies the active time interval in minutes at which periodic reports are sent to
the address specified in pktSwchSysEvRepAdd1A. A value of zero indicates that
periodic reports are disabled."
::= { pktSwchSysEvRepA 4 }
pktSwchSysEvRepMask2A OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This specifies the active conditions on which reports are sent to the address specified in
pktSwchSysEvRepAdd2A. The value is a sum of values (powers of two), where each
value in the sum represents a condition. The values that may be included in the sum and
their meanings are:
0 Disable event reports
1 Send report when SYNC status has changed
2 Send report when RTS status has changed
4 Send report at Power On (Reset)
8 Report charging information at CLR."
::= { pktSwchSysEvRepA 5 }
pktSwchSysEvRepPeriod2A OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This specifies the active time interval in minutes at which periodic reports are sent to
the address specified in pktSwchSysEvRepAdd2A. A value of zero indicates that
periodic reports are disabled."
::= { pktSwchSysEvRepA 6 }
pktSwchSysEvRepRetryCntA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of retries to send Event Reports to each port.
Possible values:
0 - Disable retry mechanism
1-255 - Number of retries "
::= { pktSwchSysEvRepA 7 }
pktSwchSysEvRepRetryDelayA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time interval between retries (in minutes).
Valid values: 1-255 "
::= { pktSwchSysEvRepA 8 }
pktSwchSysEvRepRetryOptionsA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event report options. The value is a sum of values (powers of
two), where each value in the sum represents an option. The
values that may be included in the sum and their meanings are:
0 - No Options
1 - Alternate Mode: Port 1 reports are readdressed to Port 2
on failure. (Port 2 mask is not used).
2 - Condensed Format
X - Any combination of the above values "
::= { pktSwchSysEvRepA 9 }
pktSwchSysGen OBJECT IDENTIFIER ::= { pktSwchSysParam 5 }
pktSwchSysDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is used to update the date on the device."
::= { pktSwchSysGen 1 }
pktSwchSysTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is used to update the time on the device."
::= { pktSwchSysGen 2 }
pktSwchSysAction OBJECT-TYPE
SYNTAX INTEGER {
noOp(1),
reset(2),
resetStat(3),
rearrangeNovram(4),
setDefaultConfig(5) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is used to perform imperitive commands on the device.
The reset command resets the device with the scratch values."
::= { pktSwchSysGen 3 }
pktSwchSysRamSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RAM size on the device."
::= { pktSwchSysGen 4 }
pktSwchSysNovramSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The NOVRAM size on the device."
::= { pktSwchSysGen 5 }
pktSwchSysNovramUtil OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The NOVRAM utilization on the device."
::= { pktSwchSysGen 6 }
pktSwchSysFreeDataBuff OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The free data buffers on the device."
::= { pktSwchSysGen 7 }
pktSwchSysMinDataBuffInPool OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum data buffers in the pool on the device."
::= { pktSwchSysGen 8 }
pktSwchSysProtocols OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The protocols the device can support. The value is a sum of values
(powers of two), where each value in the sum represents a protocol.
The values that may be included in the sum and their
meanings are:
1 X.25
2 Frame Relay
4 HDLC
8 SDLC
16 MPE
32 ASYNC
64 STM-4
128 STM-8
256 STM-16
512 STM-24
1024 BISYNC
2048 SLIP
4096 ETHERNET
8192 PPP
16384 ISDN
XX - Any combination of the values specified above ."
::= { pktSwchSysGen 9 }
pktSwchSysChannelProtocols OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The protocols the device can support on the async channels.
1 ASYNC
2 SLIP
3 PPP "
::= { pktSwchSysGen 10 }
pktSwchSysStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of the System data. The choices are those defined in the SNMPv2 Textual Conventions
for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus
textual convention SYNTAX."
::= { pktSwchSysParam 6 }
-- The routing subgroup in the pktSwch System Group contains the routing table, the local PVC table
-- and the net PVC table
pktSwchRouting OBJECT IDENTIFIER ::= { pktSwchSystem 2}
pktSwchRoutSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchRoutSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Scratch Routing Table defines the routes for incoming and
outgoing data on the device."
::= { pktSwchRouting 1 }
pktSwchRoutSEntry OBJECT-TYPE
SYNTAX PktSwchRoutSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the Scratch Routing Table."
INDEX { pktSwchRoutIdS }
::= { pktSwchRoutSTable 1 }
PktSwchRoutSEntry ::= SEQUENCE {
pktSwchRoutIdS
Integer32,
pktSwchRoutAddressS
DisplayString,
pktSwchRoutDestLink1S
DisplayString,
pktSwchRoutDestLink2S
DisplayString,
pktSwchRoutDestLink3S
DisplayString,
pktSwchRoutLinkPrio1S
Integer32,
pktSwchRoutLinkPrio2S
Integer32,
pktSwchRoutLinkPrio3S
Integer32,
pktSwchRoutSearchStatusS
INTEGER,
pktSwchRoutStatusS
INTEGER
}
pktSwchRoutIdS OBJECT-TYPE
SYNTAX Integer32 (1..2000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the pktSwchRoutSTable."
::= { pktSwchRoutSEntry 1 }
pktSwchRoutAddressS OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The address to which the entry applies. The use of the octet
string syntax allows the use of the letter x as a wild card in
the addresses."
::= { pktSwchRoutSEntry 2 }
pktSwchRoutDestLink1S OBJECT-TYPE
SYNTAX DisplayString -- (SIZE(6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"First destination link through which the data will be routed.
For X.25 destination: any valid x.25 link no.
For Frame Relay Link: any valid dlci with an x.25 encapsulation
protocol, presented in the form of {port:dlci}.
For a local destination: 100 .
For ISDN: ISDN routing entry number preceeded by the
letter 'I' (example: I4)"
::= { pktSwchRoutSEntry 3 }
pktSwchRoutDestLink2S OBJECT-TYPE
SYNTAX DisplayString -- (SIZE(6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Second destination link through which the data will be routed.
For X.25 destination: any valid x.25 link no.
For Frame Relay Link: any valid dlci with an x.25 encapsulation
protocol, presented in the form of {port:dlci}.
For a local destination: 100 .
For ISDN: ISDN routing entry number preceeded by the
letter 'I' (example: I4)"
::= { pktSwchRoutSEntry 4 }
pktSwchRoutDestLink3S OBJECT-TYPE
SYNTAX DisplayString -- (SIZE(6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Third destination link through which the data will be routed.
For X.25 destination: any valid x.25 link no.
For Frame Relay Link: any valid dlci with an x.25 encapsulation
protocol, presented in the form of {port:dlci}.
For a local destination: 100 .
For ISDN: ISDN routing entry number preceeded by the
letter 'I' (example: I4)"
::= { pktSwchRoutSEntry 5 }
pktSwchRoutLinkPrio1S OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A priority of the associated destination of link 1."
::= { pktSwchRoutSEntry 6 }
pktSwchRoutLinkPrio2S OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A priority of the associated destination of link 2."
::= { pktSwchRoutSEntry 7 }
pktSwchRoutLinkPrio3S OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A priority of the associated destination of link 3."
::= { pktSwchRoutSEntry 8 }
pktSwchRoutSearchStatusS OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" off - The device stops searching for a matching address.
on - The device continues searching for a matching address in the
links of the next entry."
::= { pktSwchRoutSEntry 9 }
pktSwchRoutStatusS OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this routing table entry. The choices are those defined in the SNMPv2 Textual
Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with
the RowStatus textual convention SYNTAX."
::= { pktSwchRoutSEntry 10 }
pktSwchRoutATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchRoutAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Active Routing Table defines the active routes for incoming and outgoing data
on the device."
::= { pktSwchRouting 2 }
pktSwchRoutAEntry OBJECT-TYPE
SYNTAX PktSwchRoutAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the Active Routing Table."
INDEX { pktSwchRoutIdA }
::= { pktSwchRoutATable 1 }
PktSwchRoutAEntry ::= SEQUENCE {
pktSwchRoutIdA
Integer32,
pktSwchRoutAddressA
DisplayString,
pktSwchRoutDestLink1A
DisplayString,
pktSwchRoutDestLink2A
DisplayString,
pktSwchRoutDestLink3A
DisplayString,
pktSwchRoutLinkPrio1A
Integer32,
pktSwchRoutLinkPrio2A
Integer32,
pktSwchRoutLinkPrio3A
Integer32,
pktSwchRoutSearchStatusA
INTEGER
}
pktSwchRoutIdA OBJECT-TYPE
SYNTAX Integer32 (1..2000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the pktSwchRoutATable."
::= { pktSwchRoutAEntry 1 }
pktSwchRoutAddressA OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The address to which the entry applies. The use of the octet string syntax allows
the use of the letter x as a wild card in the addresses."
::= { pktSwchRoutAEntry 2 }
pktSwchRoutDestLink1A OBJECT-TYPE
SYNTAX DisplayString -- (SIZE(6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"First destination link through which the data will be routed.
For X.25 destination: any valid x.25 link no.
For Frame Relay Link: any valid dlci with an x.25 encapsulation
protocol, presented in the form of {port:dlci}.
For a local destination: 100 .
For ISDN: ISDN routing entry number preceeded by the
letter 'I' (example: I4)"
::= { pktSwchRoutAEntry 3 }
pktSwchRoutDestLink2A OBJECT-TYPE
SYNTAX DisplayString -- (SIZE(6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Second destination link through which the data will be routed.
For X.25 destination: any valid x.25 link no.
For Frame Relay Link: any valid dlci with an x.25 encapsulation
protocol, presented in the form of {port:dlci}.
For a local destination: 100 .
For ISDN: ISDN routing entry number preceeded by the
letter 'I' (example: I4)"
::= { pktSwchRoutAEntry 4 }
pktSwchRoutDestLink3A OBJECT-TYPE
SYNTAX DisplayString -- (SIZE(6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Third destination link through which the data will be routed.
For X.25 destination: any valid x.25 link no.
For Frame Relay Link: any valid dlci with an x.25 encapsulation
protocol, presented in the form of {port:dlci}.
For a local destination: 100 .
For ISDN: ISDN routing entry number preceeded by the
letter 'I' (example: I4)"
::= { pktSwchRoutAEntry 5 }
pktSwchRoutLinkPrio1A OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A priority of the associated destination of link 1."
::= { pktSwchRoutAEntry 6 }
pktSwchRoutLinkPrio2A OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A priority of the associated destination of link 2."
::= { pktSwchRoutAEntry 7 }
pktSwchRoutLinkPrio3A OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A priority of the associated destination of link 3."
::= { pktSwchRoutAEntry 8 }
pktSwchRoutSearchStatusA OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" off - The device stops searching for a matching address.
on - The device continues searching for a matching address in the
links of the next entry."
::= { pktSwchRoutAEntry 9 }
pktSwchPvcSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchPvcSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Scratch Network PVC Table defines the network PVCs."
::= { pktSwchRouting 3 }
pktSwchPvcSEntry OBJECT-TYPE
SYNTAX PktSwchPvcSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the Scratch Network PVC table."
INDEX { pktSwchPvcNumS }
::= { pktSwchPvcSTable 1 }
PktSwchPvcSEntry ::= SEQUENCE {
pktSwchPvcNumS
Integer32,
pktSwchPvcSrcLinkS
Integer32,
pktSwchPvcSrcLcnS
DisplayString,
pktSwchPvcDstLinkS
Integer32,
pktSwchPvcDstLcnS
Integer32,
pktSwchPvcStatusS
INTEGER
}
pktSwchPvcNumS OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PVC number corresponding to this entry."
::= { pktSwchPvcSEntry 1 }
pktSwchPvcSrcLinkS OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of the link (1 through 6 for SPS-6 and 1 through 12 for SPS-12) that will be
used as a source link to create a connection by means of the PVC.
0 means that the PVC will not be active, 100 means that this pvc is Local."
::= { pktSwchPvcSEntry 2 }
pktSwchPvcSrcLcnS OBJECT-TYPE
SYNTAX DisplayString -- (SIZE(1..6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Network pvc:
The number of the logical channel (0-255) that will be used as the source
logical channel to create a connection by means of the PVC.
Local pvc:
For asynchronous channel to X.25 PVC,
Any valid Async Channel number.
For encapsulation of transparent HDLC over X25 PVC,
valid Channel numbers are:
HxM - for the main PVC.
HxB - for the backup PVC.
x is a valid HDLC link number.
For encapsulation of Multi Point Encapsulator (MPE) over X25 PVC,
valid channel numbers are:
Nx - where x is a valid MPE link number.
For encapsulation of IP Over X.25 PVC, Enter IP."
::= { pktSwchPvcSEntry 3 }
pktSwchPvcDstLinkS OBJECT-TYPE
SYNTAX Integer32 (0..12)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of the destination link that will be used.
0 means that the PVC will not be active."
::= { pktSwchPvcSEntry 4 }
pktSwchPvcDstLcnS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of the logical channel for the destination link."
::= { pktSwchPvcSEntry 5 }
pktSwchPvcStatusS OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this Network PVC table entry. The choices are those defined in the SNMPv2
Textual Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax
with the RowStatus textual convention SYNTAX."
::= { pktSwchPvcSEntry 6 }
pktSwchPvcATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchPvcAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Active Network PVC Table defines the active network PVCs."
::= { pktSwchRouting 4 }
pktSwchPvcAEntry OBJECT-TYPE
SYNTAX PktSwchPvcAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the Active Network PVC table."
INDEX { pktSwchPvcNumA }
::= { pktSwchPvcATable 1 }
PktSwchPvcAEntry ::= SEQUENCE {
pktSwchPvcNumA
Integer32,
pktSwchPvcSrcLinkA
Integer32,
pktSwchPvcSrcLcnA
DisplayString,
pktSwchPvcDstLinkA
Integer32,
pktSwchPvcDstLcnA
Integer32
}
pktSwchPvcNumA OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PVC number corresponding to this entry."
::= { pktSwchPvcAEntry 1 }
pktSwchPvcSrcLinkA OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the link (1 through 6 for SPS-6 and 1 through 12 for SPS-12) that is
used as a source link to create a connection by means of the PVC.
0 means that the PVC will not be active, 100 means that this pvc is Local."
::= { pktSwchPvcAEntry 2 }
pktSwchPvcSrcLcnA OBJECT-TYPE
SYNTAX DisplayString -- (SIZE(1..6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Network pvc:
The number of the logical channel (0-255) that will be used as the source
logical channel to create a connection by means of the PVC.
Local pvc:
For asynchronous channel to X.25 PVC,
Any valid Async Channel number.
For encapsulation of transparent HDLC over X25 PVC,
valid Channel numbers are:
HxM - for the main PVC.
HxB - for the backup PVC.
x is a valid HDLC link number.
For encapsulation of Multi Point Encapsulator (MPE) over X25 PVC,
valid channel numbers are:
Nx - where x is a valid MPE link number.
For encapsulation of IP Over X.25 PVC, Enter IP."
::= { pktSwchPvcAEntry 3 }
pktSwchPvcDstLinkA OBJECT-TYPE
SYNTAX Integer32 (0..12)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the destination link that is used.
0 means that the PVC will not be active."
::= { pktSwchPvcAEntry 4 }
pktSwchPvcDstLcnA OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the logical channel for the destination link."
::= { pktSwchPvcAEntry 5 }
-- NUI Table
pktSwchNui OBJECT IDENTIFIER ::= { pktSwchSystem 3 }
-- The NUI Table contains the Network User Identification
-- password information.
pktSwchNuiSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchNuiSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The NUI Table defines the NUIs that can be used by the device."
::= { pktSwchNui 1 }
pktSwchNuiSEntry OBJECT-TYPE
SYNTAX PktSwchNuiSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the NUI Table."
INDEX { pktSwchNuiIndexS }
::= { pktSwchNuiSTable 1 }
PktSwchNuiSEntry ::= SEQUENCE {
pktSwchNuiIndexS
Integer32,
pktSwchNuiGroupIdS
Integer32,
pktSwchNuiInPasswdS
DisplayString,
pktSwchNuiOutPasswdPointerS
Integer32,
pktSwchNuiInAddrS
DisplayString,
pktSwchNuiOutAddrPointerS
Integer32,
pktSwchNuiStatusS
INTEGER
}
pktSwchNuiIndexS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of this entry."
::= { pktSwchNuiSEntry 1 }
pktSwchNuiGroupIdS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The group Id for this NUI entry."
::= { pktSwchNuiSEntry 2 }
pktSwchNuiInPasswdS OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The password for the incoming call. 15 chars."
::= { pktSwchNuiSEntry 3 }
pktSwchNuiOutPasswdPointerS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A pointer to the password in the OutPasswdTable for an outgoing call."
::= { pktSwchNuiSEntry 4 }
pktSwchNuiInAddrS OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The addresss for the incoming call. 15 digits."
::= { pktSwchNuiSEntry 5 }
pktSwchNuiOutAddrPointerS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A pointer to the address in the OutAddrTable for an outgoing call."
::= { pktSwchNuiSEntry 6 }
pktSwchNuiStatusS OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this NUI table entry. The choices are those defined in the SNMPv2 Textual
Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with
the RowStatus textual convention SYNTAX."
::= { pktSwchNuiSEntry 7 }
pktSwchNuiATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchNuiAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The NUI Table defines the NUIs that can be used by the device."
::= { pktSwchNui 2 }
pktSwchNuiAEntry OBJECT-TYPE
SYNTAX PktSwchNuiAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the NUI Table."
INDEX { pktSwchNuiIndexA }
::= { pktSwchNuiATable 1 }
PktSwchNuiAEntry ::= SEQUENCE {
pktSwchNuiIndexA
Integer32,
pktSwchNuiGroupIdA
Integer32,
pktSwchNuiInPasswdA
DisplayString,
pktSwchNuiOutPasswdPointerA
Integer32,
pktSwchNuiInAddrA
DisplayString,
pktSwchNuiOutAddrPointerA
Integer32,
pktSwchNuiStatusA
INTEGER
}
pktSwchNuiIndexA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of this entry."
::= { pktSwchNuiAEntry 1 }
pktSwchNuiGroupIdA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The group Id for this NUI entry."
::= { pktSwchNuiAEntry 2 }
pktSwchNuiInPasswdA OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The password for the incoming call. 15 chars."
::= { pktSwchNuiAEntry 3 }
pktSwchNuiOutPasswdPointerA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A pointer to the password in the OutPasswdTable for an outgoing call."
::= { pktSwchNuiAEntry 4 }
pktSwchNuiInAddrA OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The addresss for the incoming call. 15 digits."
::= { pktSwchNuiAEntry 5 }
pktSwchNuiOutAddrPointerA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A pointer to the address in the OutAddrTable for an outgoing call."
::= { pktSwchNuiAEntry 6 }
pktSwchNuiStatusA OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of this NUI table entry. The choices are those defined in the SNMPv2 Textual
Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with
the RowStatus textual convention SYNTAX."
::= { pktSwchNuiAEntry 7 }
pktSwchNuiOutPasswdSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchNuiOutPasswdSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table defines the passwords that can be used by the device."
::= { pktSwchNui 3 }
pktSwchNuiOutPasswdSEntry OBJECT-TYPE
SYNTAX PktSwchNuiOutPasswdSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in OutPasswd Table."
INDEX { pktSwchNuiOutPasswdIndexS }
::= { pktSwchNuiOutPasswdSTable 1 }
PktSwchNuiOutPasswdSEntry ::= SEQUENCE {
pktSwchNuiOutPasswdIndexS
Integer32,
pktSwchNuiOutPasswdValueS
DisplayString,
pktSwchNuiOutPasswdStatusS
INTEGER
}
pktSwchNuiOutPasswdIndexS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of this entry."
::= { pktSwchNuiOutPasswdSEntry 1 }
pktSwchNuiOutPasswdValueS OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The password of this entry. 15 chars."
::= { pktSwchNuiOutPasswdSEntry 2 }
pktSwchNuiOutPasswdStatusS OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this NuiOutPasswd table entry."
::= { pktSwchNuiOutPasswdSEntry 3 }
pktSwchNuiOutPasswdATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchNuiOutPasswdAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table defines the passwords that can be used by the device."
::= { pktSwchNui 4 }
pktSwchNuiOutPasswdAEntry OBJECT-TYPE
SYNTAX PktSwchNuiOutPasswdAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in OutPasswd Table."
INDEX { pktSwchNuiOutPasswdIndexA }
::= { pktSwchNuiOutPasswdATable 1 }
PktSwchNuiOutPasswdAEntry ::= SEQUENCE {
pktSwchNuiOutPasswdIndexA
Integer32,
pktSwchNuiOutPasswdValueA
DisplayString,
pktSwchNuiOutPasswdStatusA
INTEGER
}
pktSwchNuiOutPasswdIndexA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of this entry."
::= { pktSwchNuiOutPasswdAEntry 1 }
pktSwchNuiOutPasswdValueA OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The password of this entry. 15 chars."
::= { pktSwchNuiOutPasswdAEntry 2 }
pktSwchNuiOutPasswdStatusA OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of this NuiOutPasswd table entry."
::= { pktSwchNuiOutPasswdAEntry 3 }
pktSwchNuiOutAddrSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchNuiOutAddrSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table defines the Addresses that can be used by the device."
::= { pktSwchNui 5 }
pktSwchNuiOutAddrSEntry OBJECT-TYPE
SYNTAX PktSwchNuiOutAddrSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in OutAddr Table."
INDEX { pktSwchNuiOutAddrIndexS }
::= { pktSwchNuiOutAddrSTable 1 }
PktSwchNuiOutAddrSEntry ::= SEQUENCE {
pktSwchNuiOutAddrIndexS
Integer32,
pktSwchNuiOutAddrValueS
DisplayString,
pktSwchNuiOutAddrStatusS
INTEGER
}
pktSwchNuiOutAddrIndexS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of this entry."
::= { pktSwchNuiOutAddrSEntry 1 }
pktSwchNuiOutAddrValueS OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The address of this entry. 15 digits."
::= { pktSwchNuiOutAddrSEntry 2 }
pktSwchNuiOutAddrStatusS OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this NuiOutAddr table entry."
::= { pktSwchNuiOutAddrSEntry 3 }
pktSwchNuiOutAddrATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchNuiOutAddrAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table defines the Addresses that can be used by the device."
::= { pktSwchNui 6 }
pktSwchNuiOutAddrAEntry OBJECT-TYPE
SYNTAX PktSwchNuiOutAddrAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in OutAddr Table."
INDEX { pktSwchNuiOutAddrIndexA }
::= { pktSwchNuiOutAddrATable 1 }
PktSwchNuiOutAddrAEntry ::= SEQUENCE {
pktSwchNuiOutAddrIndexA
Integer32,
pktSwchNuiOutAddrValueA
DisplayString,
pktSwchNuiOutAddrStatusA
INTEGER
}
pktSwchNuiOutAddrIndexA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of this entry."
::= { pktSwchNuiOutAddrAEntry 1 }
pktSwchNuiOutAddrValueA OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The address of this entry. 15 digits."
::= { pktSwchNuiOutAddrAEntry 2 }
pktSwchNuiOutAddrStatusA OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of this NuiOutAddr table entry."
::= { pktSwchNuiOutAddrAEntry 3 }
-- X25 Manager Table
pktSwchMng OBJECT IDENTIFIER ::= { pktSwchSystem 4 }
pktSwchMngX25TrapIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchMngX25Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table indicates the destination address of the traps.
Internally it will be limited to ten addresses. "
::= { pktSwchMng 1 }
pktSwchMngX25Entry OBJECT-TYPE
SYNTAX PktSwchMngX25Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table pktSwchMngX25TrapIpTable."
INDEX { pktSwchMngID }
::= {pktSwchMngX25TrapIpTable 1 }
PktSwchMngX25Entry ::=
SEQUENCE {
pktSwchMngID
Integer32,
pktSwchMngIP
IpAddress,
pktSwchMngPhyAddr
DisplayString,
pktSwchTrapEnable
Integer32,
pktSwchEncapsulationMode
INTEGER
}
pktSwchMngID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" This value indicates an index of a specific IP address"
::= { pktSwchMngX25Entry 1 }
pktSwchMngIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value indicates the destination address of the traps. IP 0.0.0.0 removes the entry. "
::= { pktSwchMngX25Entry 2 }
pktSwchMngPhyAddr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This value indicates the physical destination address of the traps."
::= { pktSwchMngX25Entry 3 }
pktSwchTrapEnable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value indicates which traps should be sent.
The value is a sum of values (powers of two), where each value in
the sum represents a trap that should be reported to the Management
Station. The values that may be included in the sum and their meanings are:
0 No traps would be reported.
1 Link Down
2 Link Up
4 rtsChange
8 resetX25
16 restartX25
32 frDLCIStatusChange
64 coldStart
128 linkProtocolChanged
256 enrollmentPS
512 ledStatusChange "
::= { pktSwchMngX25Entry 4 }
pktSwchEncapsulationMode OBJECT-TYPE
SYNTAX INTEGER {
ipPid(1),
snapPid(2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Format type for IP over X25"
::= { pktSwchMngX25Entry 5 }
-- XID Table
pktSwchXid OBJECT IDENTIFIER ::= { pktSwchSystem 5 }
pktSwchXidSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchXidSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Exchange Id table contains a list of 13 incoming pairs of allowed
dial-up phone numbers and passwords. Also included is one pair of
outgoing phone number and password (InternalIndex=14)."
::= { pktSwchXid 1 }
pktSwchXidSEntry OBJECT-TYPE
SYNTAX PktSwchXidSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table pktSwchXidSTable."
INDEX { pktSwchXidIndexS, pktSwchXidInternalIndexS }
::= {pktSwchXidSTable 1 }
PktSwchXidSEntry ::=
SEQUENCE {
pktSwchXidIndexS
Integer32,
pktSwchXidInternalIndexS
Integer32,
pktSwchXidPasswdS
DisplayString,
pktSwchXidPhoneS
DisplayString,
pktSwchXidStatusS
INTEGER
}
pktSwchXidIndexS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" This Index of the XID table."
::= { pktSwchXidSEntry 1 }
pktSwchXidInternalIndexS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An internal index for each XidIndex of the table. The first 13 entries
refer to Incoming calls. The 14th entry refers to an Outgoing call."
::= { pktSwchXidSEntry 2 }
pktSwchXidPasswdS OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Password of size 16 chars."
::= { pktSwchXidSEntry 3 }
pktSwchXidPhoneS OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Phone number of size 16 digits."
::= { pktSwchXidSEntry 4 }
pktSwchXidStatusS OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of the XID table entry. The status applies to the XidIndex,
i.e., setting the staus to invalid results in the removal of all
the InternalIndex entries (1..14) belonging to the relevant XidIndex."
::= { pktSwchXidSEntry 5 }
pktSwchXidATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchXidAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Exchange Id table contains a list of 13 incoming pairs of allowed
dial-up phone numbers and passwords. Also included is one pair of
outgoing phone number and password (InternalIndex=14)."
::= { pktSwchXid 2 }
pktSwchXidAEntry OBJECT-TYPE
SYNTAX PktSwchXidAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table pktSwchXidATable."
INDEX { pktSwchXidIndexA, pktSwchXidInternalIndexA }
::= {pktSwchXidATable 1 }
PktSwchXidAEntry ::=
SEQUENCE {
pktSwchXidIndexA
Integer32,
pktSwchXidInternalIndexA
Integer32,
pktSwchXidPasswdA
DisplayString,
pktSwchXidPhoneA
DisplayString,
pktSwchXidStatusA
INTEGER
}
pktSwchXidIndexA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" This Index of the XID table."
::= { pktSwchXidAEntry 1 }
pktSwchXidInternalIndexA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An internal index for each XidIndex of the table. The first 13 entries
refer to Incoming calls. The 14th entry refers to an Outgoing call."
::= { pktSwchXidAEntry 2 }
pktSwchXidPasswdA OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Password of size 16 chars."
::= { pktSwchXidAEntry 3 }
pktSwchXidPhoneA OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phone number of size 16 digits."
::= { pktSwchXidAEntry 4 }
pktSwchXidStatusA OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the XID table entry. The status applies to the XidIndex,
i.e., setting the staus to invalid results in the removal of all
the InternalIndex entries (1..14) belonging to the relevant XidIndex."
::= { pktSwchXidAEntry 5 }
pktSwchIpRouting OBJECT IDENTIFIER ::= { pktSwchSystem 6 }
pktSwchIpRoutSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchIpRoutSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Scratch Routing Table defines the routes for incoming and
outgoing ip datagrams on the device."
::= { pktSwchIpRouting 1 }
pktSwchIpRoutSEntry OBJECT-TYPE
SYNTAX PktSwchIpRoutSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the Scratch IP Routing
Table."
INDEX { pktSwchIpRoutIdS }
::= { pktSwchIpRoutSTable 1 }
PktSwchIpRoutSEntry ::= SEQUENCE {
pktSwchIpRoutIdS
Integer32,
pktSwchIpRoutIpAddressS
IpAddress,
pktSwchIpRoutIpMaskS
IpAddress,
pktSwchIpRoutDestProtocolS
INTEGER,
pktSwchIpRoutDestinationS
DisplayString,
pktSwchIpRoutInactivityS
Integer32,
pktSwchIpRoutStatusS
INTEGER,
pktSwchIpRoutMetricS
Integer32,
pktSwchIpRoutNextHopS
IpAddress,
pktSwchIpRoutInterfaceIdS
Integer32
}
pktSwchIpRoutIdS OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the pktSwchIpRoutSTable."
::= { pktSwchIpRoutSEntry 1 }
pktSwchIpRoutIpAddressS OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address to which the entry applies.
A string of the format: X.X.X.X
where every X is a number in the range 0-255."
::= { pktSwchIpRoutSEntry 2 }
pktSwchIpRoutIpMaskS OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP mask to which the entry applies.
A string of the format: X.X.X.X
where every X is a number in the range 0-255."
::= { pktSwchIpRoutSEntry 3 }
pktSwchIpRoutDestProtocolS OBJECT-TYPE
SYNTAX INTEGER {
slip (1),
x25SVC (2),
x25PVC (3),
frameRelay (4),
hdlc (5),
ethernet (7), -- (6) is reserved for snmp agent.
ppp (8),
none (255)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Destination protocol for the associated address.
None(255) when not used"
::= { pktSwchIpRoutSEntry 4 }
pktSwchIpRoutDestinationS OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
" Destination for the associated address.
Possible values:
Default : Not Used.
X.25 PVC: Port:LCN or a pre defined PVC number
X.25 SVC: X.25 Addr or cid followed by a predefined Call ID number
Frame Relay: Port:DLCI
HDLC: 'H' followed by the HDLC Port Number
SLIP: 'S' followed by the SLIP Channel Number
Ethernet: 'E' followed by the Ethernet Port Number
PPP: 'P' followed by the PPP Port Number."
::= { pktSwchIpRoutSEntry 5 }
pktSwchIpRoutInactivityS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Inactivity time in steps of 50 mili seconds for X25 SVC
protocol only. Range: 0..255. Default: 2."
::= { pktSwchIpRoutSEntry 6 }
pktSwchIpRoutStatusS OBJECT-TYPE
SYNTAX INTEGER {
valid (1),
createRequest(2),
underCreation(3),
invalid (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this routing table entry. The choices are those
defined in the SNMPv2 Textual Conventions for RowStatus.
This will allow easy replacement of the INTEGER syntax with
the RowStatus textual convention SYNTAX."
::= { pktSwchIpRoutSEntry 7 }
pktSwchIpRoutMetricS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"No. of hops for this route.
The default value is 1.
Legal values: 1 to the max no. of hops this device will support.
The max no. is defined by pktSwchIpGlobalMaxHopCount."
::= { pktSwchIpRoutSEntry 8 }
pktSwchIpRoutNextHopS OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP address of the next hop.
A string of the format: X.X.X.X
where every X is a number in the range 0-255."
::= { pktSwchIpRoutSEntry 9 }
pktSwchIpRoutInterfaceIdS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ID of the logical IP interface in the pktSwchIpInterface table.
The IP routing module will route the IP frame according to this
interface ID.
Legal values: 1 to 200 and 65535.
1-200 : ID of interface.
65535 : No IP interface ID.
Default value: 65535."
::= { pktSwchIpRoutSEntry 10 }
pktSwchIpRoutATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchIpRoutAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Active Routing Table defines the active routes for incoming
and outgoing ip datagrams on the device."
::= { pktSwchIpRouting 2 }
pktSwchIpRoutAEntry OBJECT-TYPE
SYNTAX PktSwchIpRoutAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the Active IP Routing Table."
INDEX { pktSwchIpRoutIdA }
::= { pktSwchIpRoutATable 1 }
PktSwchIpRoutAEntry ::= SEQUENCE {
pktSwchIpRoutIdA
Integer32,
pktSwchIpRoutIpAddressA
IpAddress,
pktSwchIpRoutIpMaskA
IpAddress,
pktSwchIpRoutDestProtocolA
INTEGER,
pktSwchIpRoutDestinationA
DisplayString,
pktSwchIpRoutInactivityA
Integer32,
pktSwchIpRoutBuffsInA
Counter32,
pktSwchIpRoutBuffsOutA
Counter32,
pktSwchIpRoutFCA
INTEGER,
pktSwchIpRoutMetricA
Integer32,
pktSwchIpRoutNextHopA
IpAddress,
pktSwchIpRoutInterfaceIdA
Integer32
}
pktSwchIpRoutIdA OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the IP pktSwchIpRoutATable."
::= { pktSwchIpRoutAEntry 1 }
pktSwchIpRoutIpAddressA OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address to which the entry applies.
A string of the format: X.X.X.X
where every X is a number in the range 0-255."
::= { pktSwchIpRoutAEntry 2 }
pktSwchIpRoutIpMaskA OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP mask to which the entry applies.
A string of the format: X.X.X.X
where every X is a number in the range 0-255."
::= { pktSwchIpRoutAEntry 3 }
pktSwchIpRoutDestProtocolA OBJECT-TYPE
SYNTAX INTEGER {
slip (1),
x25SVC (2),
x25PVC (3),
frameRelay (4),
hdlc (5),
snmpAgent (6),
ethernet (7),
ppp (8),
none (255)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Destination protocol for the associated address.
None(255) when not used."
::= { pktSwchIpRoutAEntry 4 }
pktSwchIpRoutDestinationA OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
" Destination for the associated address.
Possible values:
Default : Not Used.
X.25 PVC: Port:LCN or a pre defined PVC number
X.25 SVC: X.25 Addr or cid followed by a predefined Call ID number
Frame Relay: Port:DLCI
HDLC: 'H' followed by the HDLC Port Number
SLIP: 'S' followed by the SLIP Channel Number
Ethernet: 'E' followed by the Ethernet Port Number
PPP: 'P' followed by the PPP Port Number."
::= { pktSwchIpRoutAEntry 5 }
pktSwchIpRoutInactivityA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Inactivity time in steps of 50 mili seconds for X25 SVC
protocol only. Range: 0..255. Default: 2."
::= { pktSwchIpRoutAEntry 6 }
pktSwchIpRoutBuffsInA OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets in the Input buffer link list,
received but not routed yet."
::= { pktSwchIpRoutAEntry 7 }
pktSwchIpRoutBuffsOutA OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets in the Output buffer link list,
routed but not sent yet."
::= { pktSwchIpRoutAEntry 8 }
pktSwchIpRoutFCA OBJECT-TYPE
SYNTAX INTEGER {
discard (1),
flowControl (2),
normal (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the flow control status of this ip routing
entry\connection"
::= { pktSwchIpRoutAEntry 9 }
pktSwchIpRoutMetricA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"No. of hops for this route.
The default value is 1.
Legal values: 1 to the max no. of hops this device will support.
The max no. is defined by pktSwchIpGlobalMaxHopCount."
::= { pktSwchIpRoutAEntry 10 }
pktSwchIpRoutNextHopA OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP address of the next hop.
A string of the format: X.X.X.X
where every X is a number in the range 0-255."
::= { pktSwchIpRoutAEntry 11 }
pktSwchIpRoutInterfaceIdA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ID of the logical IP interface in the pktSwchIpInterface table.
The IP routing module will route the IP frame according to this
interface ID.
Legal values: 1 to 200 and 65535.
1-200 : ID of interface.
65535 : No IP interface ID.
Default value: 65535."
::= { pktSwchIpRoutAEntry 12 }
-- System Priorities
pktSwchPriority OBJECT IDENTIFIER ::= { pktSwchSystem 7 }
-- This is a table of Tx Priorities.
-- At present, it is used for DLCIs. There are 4 levels of priorities.
-- Each level contains 2 parameters: max delay time and max queue length.
-- This is a status which is used for saving the Tx Priority table.
pktSwchTxPriorityStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
underCreation(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of the Priorities table.
Used for saving the Priority parameters. "
::= {pktSwchPriority 1}
pktSwchTxPriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchTxPriorityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Tx Priorities table."
::= {pktSwchPriority 2}
pktSwchTxPriorityEntry OBJECT-TYPE
SYNTAX PktSwchTxPriorityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Tx Priority Entry defines the max delay time and max queue
length for each Priority level."
INDEX {pktSwchTxPriorityLevel}
::= { pktSwchTxPriorityTable 1 }
PktSwchTxPriorityEntry ::= SEQUENCE {
pktSwchTxPriorityLevel
Integer32,
pktSwchTxPriorityMaxDelayTime
Integer32,
pktSwchTxPriorityMaxQueueLen
Integer32 }
pktSwchTxPriorityLevel OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Level of an entry in the Tx Priority Table.
At present, the PS supports 4 priority levels.
Default level: 1"
::= { pktSwchTxPriorityEntry 1 }
pktSwchTxPriorityMaxDelayTime OBJECT-TYPE
SYNTAX Integer32 (0..60000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Max delay time in Tx queue (in 100 msec intervals).
Each frame will wait no more than the Max delay time until
it is handled.
0 means that the delay is Unlimited.
Default value: 0"
::= { pktSwchTxPriorityEntry 2 }
pktSwchTxPriorityMaxQueueLen OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Max allowed length of the Tx queue. Frames will be discarded
if the length is exceeded.
0 means that the queue is of Unlimited length.
Default value: 0"
::= { pktSwchTxPriorityEntry 3 }
-- The PS Async Group contains the Profile Table, the Channel Table,
-- the Call ID Table, the Alias Table, and the AsyncStat Table
pktSwchAsync OBJECT IDENTIFIER ::= { radPS 2 }
-- pktSwchProfile defines the (Scratch and Active) profiles that the Packet Switch devices can use to configure a channel
pktSwchProfile OBJECT IDENTIFIER ::= { pktSwchAsync 1 }
-- pktSwchProfileSTable defines the Scratch profiles that the Packet Switch devices can use to configure a channel
pktSwchProfileSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchProfileSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Profile Table S defines the Scratch profiles that the PS can use to configure
a channel."
::= { pktSwchProfile 1 }
pktSwchProfileSEntry OBJECT-TYPE
SYNTAX PktSwchProfileSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the Profile Table S."
INDEX { pktSwchProfileNumberS }
::= { pktSwchProfileSTable 1 }
PktSwchProfileSEntry ::= SEQUENCE {
pktSwchProfileNumberS
Integer32,
pktSwchProfileRecallCharS
Integer32,
pktSwchProfileEchoS
INTEGER,
pktSwchProfileDataForwCharS
Integer32,
pktSwchProfileIdleTimerS
Integer32,
pktSwchProfileDevFlowContS
INTEGER,
pktSwchProfileServSigS
INTEGER,
pktSwchProfileBreakS
Integer32,
pktSwchProfileDiscOutS
INTEGER,
pktSwchProfileCRPaddingS
Integer32,
pktSwchProfileLineFoldS
Integer32,
pktSwchProfileSpeedS
INTEGER,
pktSwchProfilePadFlowContS
INTEGER,
pktSwchProfileLineFeedInsertS
INTEGER,
pktSwchProfileLineFeedPadS
Integer32,
pktSwchProfileEditingS
INTEGER,
pktSwchProfileCharDelS
Integer32,
pktSwchProfileLineDelS
Integer32,
pktSwchProfileLineDispS
Integer32,
pktSwchProfileEditServSigS
Integer32,
pktSwchProfileEchomaskS
Integer32,
pktSwchProfileParTreatS
INTEGER,
pktSwchProfilePageWaitS
Integer32,
pktSwchProfileBitsPerCharS
Integer32,
pktSwchProfileDvParityS
INTEGER,
pktSwchProfileStopBitsS
INTEGER,
pktSwchProfileSpecFlowS
INTEGER,
pktSwchProfileCountFwdS
Integer32,
pktSwchProfileEscDelayS
Integer32,
pktSwchProfileCharBreakS
Integer32,
pktSwchProfileCharSuppressS
Integer32,
pktSwchProfileCharSubsS
Integer32,
pktSwchProfileFormFeedPadS
Integer32,
pktSwchProfileInactivityS
Integer32,
pktSwchProfileOptionsS
Integer32,
pktSwchProfileClrTimerS
Integer32,
pktSwchProfileSubAddInCUDS
Integer32,
pktSwchProfileStatusS
INTEGER,
pktSwchProfileIncomingMsgS
DisplayString,
pktSwchProfileOutgoingMsgS
DisplayString,
pktSwchProfileClearMsgS
DisplayString
}
pktSwchProfileNumberS OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number by which a profile is identified. This is also used as the index for the profile table.
The maximum profile number is 200."
::= { pktSwchProfileSEntry 1 }
pktSwchProfileRecallCharS OBJECT-TYPE
SYNTAX Integer32 (0..126)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The character specified by this entry is used to escape from the data transfer
mode and enter the PAD command mode. The integer values have the following meanings:
(0) PAD recall is not possible
(1) The PAD recall character is DLE
(2) to (126) The PAD recall character is specified by the user by entering its ASCII
code."
::= { pktSwchProfileSEntry 2 }
pktSwchProfileEchoS OBJECT-TYPE
SYNTAX INTEGER {
echEn(1),
noEch(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This determines if an echo of the input characters is retured to the DTE.
The options are either 'echo enabled' or 'no echo'."
::= { pktSwchProfileSEntry 3 }
pktSwchProfileDataForwCharS OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value is a sum of values (powers of two), where each value in the sum represents
a character (or characters) that is (are) used as a data forwarding character. The data
forwarding characters are used to instruct the PAD to complete the assembly of and to
forward a packet containing the data accumulated up to the reception of such a character.
The values that may be included in the sum and their meanings are:
0 Data forwarding characters are not used
1 Alpha-numeric characters (A to Z, a to z, 0 to 9, inclusive)
2 Character CR
4 Characters ESC, BEL, ENQ, ACK
8 Characters DEL, CAN, DC2
16 Characters EOT, ETX
32 Characters HT, LF, VT, FF
64 All the other characters in colums 0 and 1 of IA5 and not listed above."
::= { pktSwchProfileSEntry 4 }
pktSwchProfileIdleTimerS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Packets will be forwarded when the idle timer expires. The idle time interval is specified
as a multiple of 50 milliseconds. The multiple is given by the parameter value. For example,
a value of 60 sets an interval of 3 seconds. If the parameter value is 0, no forwarding occurs
after the idle condition."
::= { pktSwchProfileSEntry 5 }
pktSwchProfileDevFlowContS OBJECT-TYPE
SYNTAX INTEGER {
trans(1),
transAndCom(2),
noFlow(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter determines whether or not the PAD uses software flow control for the
attached device. The options are either (1) PAD uses flow control during data transfer
mode, (2) PAD uses flow control both in the data transfer mode and in the command mode,
or (255) PAD does not use flow control."
::= { pktSwchProfileSEntry 6 }
pktSwchProfileServSigS OBJECT-TYPE
SYNTAX INTEGER {
serv(1),
prompt(4),
servAndPrompt(5),
noSig(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is used to instruct the PAD whether to transfer PAD service signals and
the PAD prompt to the local DTE in standard format. The options are (1) PAD service
signals are transmitted to the DTE using the standard format, (4) The PAD prompt is
transmitted using the standard format, (5) PAD service signals and the PAD prompt are
transmitted in the standard format, or (255) No PAD service signals are transmitted to the
DTE."
::= { pktSwchProfileSEntry 7 }
pktSwchProfileBreakS OBJECT-TYPE
SYNTAX Integer32 (0..31)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value is a sum of values (powers of two), where each value in the sum represents
a PAD operation on receipt of the break signal from the DTE.
The values that may be included in the sum and their meanings are:
0 Nothing
1 Send interrupt packet to network
2 Send RESET packet to network
4 Send and 'indication of break' message
8 Escape from data transfer mode
16 Discard output data waiting to be sent to the DTE ."
::= { pktSwchProfileSEntry 8 }
pktSwchProfileDiscOutS OBJECT-TYPE
SYNTAX INTEGER {
discOut(1),
normal(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter instructs the PAD whether to forward the user sequences included in
data packets to the local DTE or discard them. The options are (1) discard output or
(2) normal data delivery. If the value of radSPSProfileBreak is 21, the value of
pktSwchProfileDiscOut is automatically set to (1) when a break signal is received."
::= { pktSwchProfileSEntry 9 }
pktSwchProfileCRPaddingS OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter specifies the number of padding characters to be added after a carriage
return character is transmitted to the local DTE."
::= { pktSwchProfileSEntry 10}
pktSwchProfileLineFoldS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter specifies the maximum number of characters to be inserted before the
format effector. If the value is zero, there is no insertion of a format effector (line folding)."
::= { pktSwchProfileSEntry 11}
pktSwchProfileSpeedS OBJECT-TYPE
SYNTAX INTEGER {
s110bps(1),
s300bps(2),
s1200bps(3),
s600bps(4),
s75bps(5),
s150bps(6),
s2400bps(12),
s4800bps(13),
s9600bps(14),
s19200bps(15),
s38400bps(19),
s57600bps(20),
s115200bps(21)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter determines the rate of data transmission to and from the DTE."
::= { pktSwchProfileSEntry 12 }
pktSwchProfilePadFlowContS OBJECT-TYPE
SYNTAX INTEGER {
flowCont(1),
noFlowCont(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This determines whether or not the terminal can exercise flow control over the PAD.
The options are either 'device can exercise flow control' or 'device cannot exercise flow
control."
::= { pktSwchProfileSEntry 13 }
pktSwchProfileLineFeedInsertS OBJECT-TYPE
SYNTAX INTEGER {
afterCR(1),
recCR(2),
echoCR(4),
onePlusFour(5),
twoPlusFour(6),
oneTwoFour(7),
noFeed(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates when there is a line feed insertion after CR. The options are
(1) Insert line feed after transmission of CR to the DTE, (2) Insert line feed after receipt
of CR from the DTE, (4) Insert line feed after echoing a CR character to the DTE,
(5) Combination of (1) and (4), (6) Insert line feed after any CR to the DTE (combination of
(2) and (4)), (7) Combination of (1), (2), and (4), or (255) No line feed insertion."
::= { pktSwchProfileSEntry 14 }
pktSwchProfileLineFeedPadS OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter specifies the number of padding characters to be added after a line
feed."
::= { pktSwchProfileSEntry 15 }
pktSwchProfileEditingS OBJECT-TYPE
SYNTAX INTEGER {
edit(1),
noEdit(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter specifies the editing capabilities available in the data transfer mode.
Editing is always possible when the PAD is in the command mode. The options are
(1) Command editing in the data trasfer mode is enabled or (2) No command editing
in the data transfer mode."
::= { pktSwchProfileSEntry 16 }
pktSwchProfileCharDelS OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter specifies the character delete, which is one character from IA5. The default
selection is 127 (character DEL)."
::= { pktSwchProfileSEntry 17}
pktSwchProfileLineDelS OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter specifies the line delete (last line stored in the edit buffer), which is one character from IA5. The default
selection is 24 (character CAN)."
::= { pktSwchProfileSEntry 18}
pktSwchProfileLineDispS OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry specifies the line display character, which is one character
from IA5. The default selection is 18 (character DC2)."
::= { pktSwchProfileSEntry 19}
pktSwchProfileEditServSigS OBJECT-TYPE
SYNTAX Integer32 (0..126)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry specifies the editing PAD service signals.
The integer values have the following meanings:
(0) No editing PAD service signals
(1) Editing PAD service signals for printing terminals
(2) Editing PAD service signals for display terminals
(3) to (126) Editing PAD service signals using the desired character from IA5."
::= { pktSwchProfileSEntry 20 }
pktSwchProfileEchomaskS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value is a sum of values (powers of two), where each value in the sum represents
a character (or characters) that is (are) included in the echo mask. The characters in the
echo mask are not echoed to the DTE when PAD echo is enabled.
The values that may be included in the sum and their meanings are:
0 No echo mask (all the characters are echoed)
1 No echo of character CR
2 No echo of character LF
4 No echo of characters VT, HT, FF
8 No echo of characters BEL, BS
16 No echo of characters ESC, ENQ
32 No echo of characters ACK, NAK, STX, SOH, EOT, ETB, ETX
64 No echo of the editing characters selected by radSPSProfileCharDel,
radSPSProfileLineDel, and
radSPSProfileLineDisp
128 No echo of the DEL character and of all the other characters in the range of
ASCII 00 through 31 not mentioned above."
::= { pktSwchProfileSEntry 21 }
pktSwchProfileParTreatS OBJECT-TYPE
SYNTAX INTEGER {
parCheck(1),
parGen(2),
checkAndGen(3),
noPar(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry controls the generation of parity bits in the data sent to the local DTE and the
checking of the parity bit when generated by the local DTE. The options are (1) parity
checking is enabled, (2) parity generation is enabled, (3) parity checking and generation are
enabled, or (255) no parity checking nor parity generation."
::= { pktSwchProfileSEntry 22 }
pktSwchProfilePageWaitS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry specifies the number of line feed characters counted by the PAD before the
page wait condition is entered. If the value is zero, page wait is disabled."
::= { pktSwchProfileSEntry 23}
pktSwchProfileBitsPerCharS OBJECT-TYPE
SYNTAX Integer32 (5..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of data bits per character supported by the PAD."
::= { pktSwchProfileSEntry 24 }
pktSwchProfileDvParityS OBJECT-TYPE
SYNTAX INTEGER {
space(1),
mark(2),
even(3),
odd(4),
none(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry selects the type of parity to be checked and or generated by the PAD
when radSPSProfileParTreat is a value other than 255. The options are
(1) space parity, (2) mark parity, (3) even parity, (4) odd parity, or (255) no parity."
::= { pktSwchProfileSEntry 25 }
pktSwchProfileStopBitsS OBJECT-TYPE
SYNTAX INTEGER {
one(1),
two(2),
oneAndHalf(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates the number of stop bits per character supported by the PAD.
The options are either (1) one stop bit, (2) two stop bits, or (3) 1.5 stop bits."
::= { pktSwchProfileSEntry 26 }
pktSwchProfileSpecFlowS OBJECT-TYPE
SYNTAX INTEGER {
spec(1),
noSpec(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry is used to define additional flow control possiblilites.
The options are either (1) Flow control by means of the terminal DTR line
or (2) No special flow control."
::= { pktSwchProfileSEntry 27 }
pktSwchProfileCountFwdS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry can be used to instruct the PAD to complete the assembly of a packet
and to forward it after the specifed number of characters has been received.
If the value is zero, count forwarding is disabled."
::= { pktSwchProfileSEntry 28}
pktSwchProfileEscDelayS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry can be used to instruct the PAD whether to delay the forwarding of
a data packet when an escape character is detected in the data stream and to
determine the required delay. The packet forwarding is delayed until the specified
number of characters is received after the escape character. A value of zero indicates
no special handling( at the moment up to 10 chars are accepted)."
::= { pktSwchProfileSEntry 29}
pktSwchProfileCharBreakS OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry specifies the decimal value of the character that will be interpreted
as an additional break signal by the PAD. A value of zero indicates no break character."
::= { pktSwchProfileSEntry 30}
pktSwchProfileCharSuppressS OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry specifies the decimal value of the character that will toggle
echo suppression in the PAD. A value of zero indicates that echo suppression
is only controlled by radSPSProfileEcho."
::= { pktSwchProfileSEntry 31}
pktSwchProfileCharSubsS OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry specifies the decimal value of the character that will be echoed
instead of the character received from the user's DTE. A zero value indicates that
no character is echoed."
::= { pktSwchProfileSEntry 32}
pktSwchProfileFormFeedPadS OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry specifies the number of padding (NUL) characters that will be
automatically sent after the form feed character."
::= { pktSwchProfileSEntry 33}
pktSwchProfileInactivityS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry specifies the number of minutes after which the PAD will forward
the accumulated data and clear the call. A zero value indicates no disconnection
on inactivity."
::= { pktSwchProfileSEntry 34 }
pktSwchProfileOptionsS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry defines several options to control the profile. The value is a sum of values
(powers of two), where each value in the sum represents an option .
The values that may be included in the sum and their meanings are:
0 No options
1 Remote set of local X.3 parameters through X.29 is disabled
2 Add sub address to call request
4 Don't use protocol ID in user data field.
8 SPRINT NUI format
16 More bit is set when the edit buffer is full
32 Extended error message
64 Discard connect extended service signal
128 enable connect by typing the address w/out a command"
::= { pktSwchProfileSEntry 35 }
pktSwchProfileClrTimerS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry specifies the number of minutes after which a call is cleared.
If the parameter value is 0, there is no disconnection timer."
::= { pktSwchProfileSEntry 36 }
pktSwchProfileSubAddInCUDS OBJECT-TYPE
SYNTAX Integer32 (0..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry defines the number of digits for the subaddress in CUD."
::= { pktSwchProfileSEntry 37 }
pktSwchProfileStatusS OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this profile. The choices are those defined in the SNMPv2 Textual Conventions
for RowStatus. This will allow easy replacement of the INTEGER syntax with the RowStatus
textual convention SYNTAX."
::= { pktSwchProfileSEntry 38 }
pktSwchProfileIncomingMsgS OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables the asynchronous user to change the 'com' message for
Incoming calls to a string of up to 20 characters.
If user selects the value xxx for this object, the PAD will convert it to
the relevant X.25 address, followed by CR LF COM (Carriage-Return, Line-Feed,
com).
Example: 'called by XXX' will be converted to 'called by <X.25 address> com'."
::= { pktSwchProfileSEntry 39 }
pktSwchProfileOutgoingMsgS OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables the asynchronous user to change the 'com' message for
Outgoing calls to a string of up to 20 characters.
If user selects the value xxx for this object, the PAD will convert it to
the relevant X.25 address, followed by CR LF COM (Carriage-Return, Line-Feed,
com)."
::= { pktSwchProfileSEntry 40 }
pktSwchProfileClearMsgS OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables the user to edit a message, which will appear when
the channel is cleared. The message is a string of up to 20 characters.
Example of such a string: 'Call Cleared'."
::= { pktSwchProfileSEntry 41 }
-- pktSwchProfileATable defines the Active profiles that the Packet Switch devices can use to configure a channel
pktSwchProfileATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchProfileAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Profile Table defines the profiles that the PS can use to configure
a channel."
::= { pktSwchProfile 2 }
pktSwchProfileAEntry OBJECT-TYPE
SYNTAX PktSwchProfileAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the Profile Table."
INDEX { pktSwchProfileNumberA }
::= { pktSwchProfileATable 1 }
PktSwchProfileAEntry ::= SEQUENCE {
pktSwchProfileNumberA
Integer32,
pktSwchProfileRecallCharA
Integer32,
pktSwchProfileEchoA
INTEGER,
pktSwchProfileDataForwCharA
Integer32,
pktSwchProfileIdleTimerA
Integer32,
pktSwchProfileDevFlowContA
INTEGER,
pktSwchProfileServSigA
INTEGER,
pktSwchProfileBreakA
Integer32,
pktSwchProfileDiscOutA
INTEGER,
pktSwchProfileCRPaddingA
Integer32,
pktSwchProfileLineFoldA
Integer32,
pktSwchProfileSpeedA
INTEGER,
pktSwchProfilePadFlowContA
INTEGER,
pktSwchProfileLineFeedInsertA
INTEGER,
pktSwchProfileLineFeedPadA
Integer32,
pktSwchProfileEditingA
INTEGER,
pktSwchProfileCharDelA
Integer32,
pktSwchProfileLineDelA
Integer32,
pktSwchProfileLineDispA
Integer32,
pktSwchProfileEditServSigA
Integer32,
pktSwchProfileEchomaskA
Integer32,
pktSwchProfileParTreatA
INTEGER,
pktSwchProfilePageWaitA
Integer32,
pktSwchProfileBitsPerCharA
Integer32,
pktSwchProfileDvParityA
INTEGER,
pktSwchProfileStopBitsA
INTEGER,
pktSwchProfileSpecFlowA
INTEGER,
pktSwchProfileCountFwdA
Integer32,
pktSwchProfileEscDelayA
Integer32,
pktSwchProfileCharBreakA
Integer32,
pktSwchProfileCharSuppressA
Integer32,
pktSwchProfileCharSubsA
Integer32,
pktSwchProfileFormFeedPadA
Integer32,
pktSwchProfileInactivityA
Integer32,
pktSwchProfileOptionsA
Integer32,
pktSwchProfileClrTimerA
Integer32,
pktSwchProfileSubAddInCUDA
Integer32,
pktSwchProfileIncomingMsgA
DisplayString,
pktSwchProfileOutgoingMsgA
DisplayString,
pktSwchProfileClearMsgA
DisplayString
}
pktSwchProfileNumberA OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number by which a profile is identified. This is also used as the index for the profile table.
The maximum profile number is 200."
::= { pktSwchProfileAEntry 1 }
pktSwchProfileRecallCharA OBJECT-TYPE
SYNTAX Integer32 (0..126)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The character specified by this entry is used to escape from the data transfer
mode and enter the PAD command mode. The integer values have the following meanings:
(0) PAD recall is not possible
(1) The PAD recall character is DLE
(2) to (126) The PAD recall character is specified by the user by entering its ASCII
code."
::= { pktSwchProfileAEntry 2 }
pktSwchProfileEchoA OBJECT-TYPE
SYNTAX INTEGER {
echEn(1),
noEch(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This determines if an echo of the input characters is retured to the DTE.
The options are either 'echo enabled' or 'no echo'."
::= { pktSwchProfileAEntry 3 }
pktSwchProfileDataForwCharA OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value is a sum of values (powers of two), where each value in the sum represents
a character (or characters) that is (are) used as a data forwarding character. The data
forwarding characters are used to instruct the PAD to complete the assembly of and to
forward a packet containing the data accumulated up to the reception of such a character.
The values that may be included in the sum and their meanings are:
0 Data forwarding characters are not used
1 Alpha-numeric characters (A to Z, a to z, 0 to 9, inclusive)
2 Character CR
4 Characters ESC, BEL, ENQ, ACK
8 Characters DEL, CAN, DC2
16 Characters EOT, ETX
32 Characters HT, LF, VT, FF
64 All the other characters in colums 0 and 1 of IA5 and not listed above."
::= { pktSwchProfileAEntry 4 }
pktSwchProfileIdleTimerA OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packets will be forwarded when the idle timer expires. The idle time interval is specified
as a multiple of 50 milliseconds. The multiple is given by the parameter value. For example,
a value of 60 sets an interval of 3 seconds. If the parameter value is 0, no forwarding occurs
after the idle condition."
::= { pktSwchProfileAEntry 5 }
pktSwchProfileDevFlowContA OBJECT-TYPE
SYNTAX INTEGER {
trans(1),
transAndCom(2),
noFlow(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter determines whether or not the PAD uses software flow control for the
attached device. The options are either (1) PAD uses flow control during data transfer
mode, (2) PAD uses flow control both in the data transfer mode and in the command mode,
or (255) PAD does not use flow control."
::= { pktSwchProfileAEntry 6 }
pktSwchProfileServSigA OBJECT-TYPE
SYNTAX INTEGER {
serv(1),
prompt(4),
servAndPrompt(5),
noSig(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter is used to instruct the PAD whether to transfer PAD service signals and
the PAD prompt to the local DTE in standard format. The options are (1) PAD service
signals are transmitted to the DTE using the standard format, (4) The PAD prompt is
transmitted using the standard format, (5) PAD service signals and the PAD prompt are
transmitted in the standard format, or (255) No PAD service signals are transmitted to the
DTE."
::= { pktSwchProfileAEntry 7 }
pktSwchProfileBreakA OBJECT-TYPE
SYNTAX Integer32 (0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value is a sum of values (powers of two), where each value in the sum represents
a PAD operation on receipt of the break signal from the DTE.
The values that may be included in the sum and their meanings are:
0 Nothing
1 Send interrupt packet to network
2 Send RESET packet to network
4 Send and 'indication of break' message
8 Escape from data transfer mode
16 Discard output data waiting to be sent to the DTE ."
::= { pktSwchProfileAEntry 8 }
pktSwchProfileDiscOutA OBJECT-TYPE
SYNTAX INTEGER {
discOut(1),
normal(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter instructs the PAD whether to forward the user sequences included in
data packets to the local DTE or discard them. The options are (1) discard output or
(2) normal data delivery. If the value of radSPSProfileBreak is 21, the value of
pktSwchProfileDiscOut is automatically set to (1) when a break signal is received."
::= { pktSwchProfileAEntry 9 }
pktSwchProfileCRPaddingA OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter specifies the number of padding characters to be added after a carriage
return character is transmitted to the local DTE."
::= { pktSwchProfileAEntry 10}
pktSwchProfileLineFoldA OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter specifies the maximum number of characters to be inserted before the
format effector. If the value is zero, there is no insertion of a format effector (line folding)."
::= { pktSwchProfileAEntry 11}
pktSwchProfileSpeedA OBJECT-TYPE
SYNTAX INTEGER {
s110bps(1),
s300bps(2),
s1200bps(3),
s600bps(4),
s75bps(5),
s150bps(6),
s2400bps(12),
s4800bps(13),
s9600bps(14),
s19200bps(15),
s38400bps(19),
s57600bps(20),
s115200bps(21)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter determines the rate of data transmission to and from the DTE."
::= { pktSwchProfileAEntry 12 }
pktSwchProfilePadFlowContA OBJECT-TYPE
SYNTAX INTEGER {
flowCont(1),
noFlowCont(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This determines whether or not the terminal can exercise flow control over the PAD.
The options are either 'device can exercise flow control' or 'device cannot exercise flow
control."
::= { pktSwchProfileAEntry 13 }
pktSwchProfileLineFeedInsertA OBJECT-TYPE
SYNTAX INTEGER {
afterCR(1),
recCR(2),
echoCR(4),
onePlusFour(5),
twoPlusFour(6),
oneTwoFour(7),
noFeed(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates when there is a line feed insertion after CR. The options are
(1) Insert line feed after transmission of CR to the DTE, (2) Insert line feed after receipt
of CR from the DTE, (4) Insert line feed after echoing a CR character to the DTE,
(5) Combination of (1) and (4), (6) Insert line feed after any CR to the DTE (combination of
(2) and (4)), (7) Combination of (1), (2), and (4), or (255) No line feed insertion."
::= { pktSwchProfileAEntry 14 }
pktSwchProfileLineFeedPadA OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter specifies the number of padding characters to be added after a line
feed."
::= { pktSwchProfileAEntry 15 }
pktSwchProfileEditingA OBJECT-TYPE
SYNTAX INTEGER {
edit(1),
noEdit(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter specifies the editing capabilities available in the data transfer mode.
Editing is always possible when the PAD is in the command mode. The options are
(1) Command editing in the data trasfer mode is enabled or (2) No command editing
in the data transfer mode."
::= { pktSwchProfileAEntry 16 }
pktSwchProfileCharDelA OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter specifies the character delete, which is one character from IA5. The default
selection is 127 (character DEL)."
::= { pktSwchProfileAEntry 17}
pktSwchProfileLineDelA OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter specifies the line delete, which is one character from IA5. The default
selection is 24 (character CAN)."
::= { pktSwchProfileAEntry 18}
pktSwchProfileLineDispA OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the line display character, which is one character
from IA5. The default selection is 18 (character DC2)."
::= { pktSwchProfileAEntry 19}
pktSwchProfileEditServSigA OBJECT-TYPE
SYNTAX Integer32 (0..126)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the editing PAD service signals.
The integer values have the following meanings:
(0) No editing PAD service signals
(1) Editing PAD service signals for printing terminals
(2) Editing PAD service signals for display terminals
(3) to (126) Editing PAD service signals using the desired character from IA5."
::= { pktSwchProfileAEntry 20 }
pktSwchProfileEchomaskA OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value is a sum of values (powers of two), where each value in the sum represents
a character (or characters) that is (are) included in the echo mask. The characters in the
echo mask are not echoed to the DTE when PAD echo is enabled.
The values that may be included in the sum and their meanings are:
0 No echo mask (all the characters are echoed)
1 No echo of character CR
2 No echo of character LF
4 No echo of characters VT, HT, FF
8 No echo of characters BEL, BS
16 No echo of characters ESC, ENQ
32 No echo of characters ACK, NAK, STX, SOH, EOT, ETB, ETX
64 No echo of the editing characters selected by radSPSProfileCharDel,
radSPSProfileLineDel, and
radSPSProfileLineDisp
128 No echo of the DEL character and of all the other characters in the range of
ASCII 00 through 31 not mentioned above."
::= { pktSwchProfileAEntry 21 }
pktSwchProfileParTreatA OBJECT-TYPE
SYNTAX INTEGER {
parCheck(1),
parGen(2),
checkAndGen(3),
noPar(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry controls the generation of parity bits in the data sent to the local DTE and the
checking of the parity bit when generated by the local DTE. The options are (1) parity
checking is enabled, (2) parity generation is enabled, (3) parity checking and generation are
enabled, or (255) no parity checking nor parity generation."
::= { pktSwchProfileAEntry 22 }
pktSwchProfilePageWaitA OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the number of line feed characters counted by the PAD before the
page wait condition is entered. If the value is zero, page wait is disabled."
::= { pktSwchProfileAEntry 23}
pktSwchProfileBitsPerCharA OBJECT-TYPE
SYNTAX Integer32 (5..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data bits per character supported by the PAD."
::= { pktSwchProfileAEntry 24 }
pktSwchProfileDvParityA OBJECT-TYPE
SYNTAX INTEGER {
space(1),
mark(2),
even(3),
odd(4),
none(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry selects the type of parity to be checked and or generated by the PAD
when radSPSProfileParTreat is a value other than 255. The options are
(1) space parity, (2) mark parity, (3) even parity, (4) odd parity, or (255) no parity."
::= { pktSwchProfileAEntry 25 }
pktSwchProfileStopBitsA OBJECT-TYPE
SYNTAX INTEGER {
one(1),
two(2),
oneAndHalf(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the number of stop bits per character supported by the PAD.
The options are either (1) one stop bit, (2) two stop bits, or (3) 1.5 stop bits."
::= { pktSwchProfileAEntry 26 }
pktSwchProfileSpecFlowA OBJECT-TYPE
SYNTAX INTEGER {
spec(1),
noSpec(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry is used to define additional flow control possiblilites.
The options are either (1) Flow control by means fo the terminal DTR line
or (2) No special flow control."
::= { pktSwchProfileAEntry 27 }
pktSwchProfileCountFwdA OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry can be used to instruct the PAD to complete the assembly of a packet
and to forward it after the specifed number of characters has been received.
If the value is zero, count forwarding is disabled."
::= { pktSwchProfileAEntry 28}
pktSwchProfileEscDelayA OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry can be used to instruct the PAD whether to delay the forwarding of
a data packet when an escape character is detected in the data stream and to
determine the required delay. The packet forwarding is delayed until the specified
number of characters is received after the escape character. A value of zero indicates
no special handling."
::= { pktSwchProfileAEntry 29}
pktSwchProfileCharBreakA OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the decimal value of the character that will be interpreted
as an additional break signal by the PAD. A value of zero indicates no break character."
::= { pktSwchProfileAEntry 30}
pktSwchProfileCharSuppressA OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the decimal value of the character that will toggle
echo suppression in the PAD. A value of zero indicates that echo suppression
is only controlled by radSPSProfileEcho."
::= { pktSwchProfileAEntry 31}
pktSwchProfileCharSubsA OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the decimal value of the character that will be echoed
instead of the character received from the user's DTE. A zero value indicates that
no character is echoed."
::= { pktSwchProfileAEntry 32}
pktSwchProfileFormFeedPadA OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the number of padding (NUL) characters that will be
automatically sent after the form feed character."
::= { pktSwchProfileAEntry 33}
pktSwchProfileInactivityA OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the number of minutes after which the PAD will forward
the accumulated data and clear the call. A zero value indicates no disconnection
on inactivity."
::= { pktSwchProfileAEntry 34 }
pktSwchProfileOptionsA OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry defines several options to control the profile. The value is a sum of values
(powers of two), where each value in the sum represents an option .
The values that may be included in the sum and their meanings are:
0 No options
1 Remote set of local X.3 parameters though X.29 is disabled
2 Add sub address to call request
4 Don't use protocol ID in user data field.
8 SPRINT NUI format
16 More bit is set when the edit buffer is full
32 Extended error message
64 Discard connect extended service signal
128 enable connect by typing the address w/out a command"
::= { pktSwchProfileAEntry 35 }
pktSwchProfileClrTimerA OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the number of minutes after which a call is cleared.
If the parameter value is 0, there is no disconnection timer."
::= { pktSwchProfileAEntry 36 }
pktSwchProfileSubAddInCUDA OBJECT-TYPE
SYNTAX Integer32 (0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry defines the number of digits for the subaddress in CUD."
::= { pktSwchProfileAEntry 37 }
pktSwchProfileIncomingMsgA OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used by an asynchronous user to change the 'com' message for
Incoming calls to a string of up to 20 characters.
If user selects the value xxx for this object, the PAD will convert it to
the relevant X.25 address, followed by CR LF COM (Carriage-Return, Line-Feed,
com).
Example: 'called by XXX' will be converted to 'called by <X.25 address> com'."
::= { pktSwchProfileAEntry 38 }
pktSwchProfileOutgoingMsgA OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used by an asynchronous user to change the 'com' message for
Outgoing calls to a string of up to 20 characters.
If user selects the value xxx for this object, the PAD will convert it to
the relevant X.25 address, followed by CR LF COM (Carriage-Return, Line-Feed,
com)."
::= { pktSwchProfileAEntry 39 }
pktSwchProfileClearMsgA OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the message selected by user, which will appear when
the channel is cleared. The message is a string of up to 20 characters.
Example of such a string: 'Call Cleared'."
::= { pktSwchProfileAEntry 40 }
-- pktSwchChannel (Scratch and Active) defines the channel configurations
-- of all the channels on the PS
pktSwchChannel OBJECT IDENTIFIER ::= { pktSwchAsync 2 }
-- pktSwchChannelSTable defines the Scratch channel configurations of all
-- the channels on the PS
pktSwchChannelSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchChannelSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Scratch Channel Table defines the channels configured on the PS."
::= { pktSwchChannel 1 }
pktSwchChannelSEntry OBJECT-TYPE
SYNTAX PktSwchChannelSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the Scratch Channel Table."
INDEX { pktSwchChannelIfIndexS }
::= { pktSwchChannelSTable 1 }
PktSwchChannelSEntry ::= SEQUENCE {
pktSwchChannelIfIndexS
Integer32,
pktSwchChannelNumberS
Integer32,
pktSwchChannelProfileS
Integer32,
pktSwchChannelOutCallProfileS
Integer32,
pktSwchChannelInCallProfileS
Integer32,
pktSwchChannelRemoteProfileS
Integer32,
pktSwchChannelAutocallIdS
Integer32,
pktSwchChannelAlterAutocallIdS
Integer32,
pktSwchChannelAutocallRetriesS
Integer32,
pktSwchChannelAutocallIntervalS
Integer32,
pktSwchChannelCallAliasS
Integer32,
pktSwchChannelSubAddress1S
Integer32,
pktSwchChannelSubAddress2S
Integer32,
pktSwchChannelNUISEntry
Integer32,
pktSwchChannelClearTimerS
Integer32,
pktSwchChannelOptionsS
Integer32,
pktSwchChannelClear
INTEGER,
pktSwchChannelCopyTo
Integer32,
pktSwchChannelCopyToWMask
Integer32,
pktSwchChannelCopyMask
Integer32
}
pktSwchChannelIfIndexS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is used as the index for the channel table."
::= { pktSwchChannelSEntry 1 }
pktSwchChannelNumberS OBJECT-TYPE
SYNTAX Integer32 (1..1224)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number by which a channel is identified."
::= { pktSwchChannelSEntry 2 }
pktSwchChannelProfileS OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The profile that the channel uses for command mode operations."
::= { pktSwchChannelSEntry 3 }
pktSwchChannelOutCallProfileS OBJECT-TYPE
SYNTAX Integer32 (0..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of the profile that will be used during an outgoing
call on the channel."
::= { pktSwchChannelSEntry 4 }
pktSwchChannelInCallProfileS OBJECT-TYPE
SYNTAX Integer32 (0..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of the profile that will be used during an incoming
call on the channel."
::= { pktSwchChannelSEntry 5 }
pktSwchChannelRemoteProfileS OBJECT-TYPE
SYNTAX Integer32 (0..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of the profile that will be downloaded to the remote
PAD at the beginning of a new call."
::= { pktSwchChannelSEntry 6 }
pktSwchChannelAutocallIdS OBJECT-TYPE
SYNTAX Integer32 (0..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the mnemonic (call ID) to be used as the first alternative.
A value of zero indicates that the autocall function is disabled."
::= { pktSwchChannelSEntry 7 }
pktSwchChannelAlterAutocallIdS OBJECT-TYPE
SYNTAX Integer32 (0..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the alternate mnemonic for the autocall function. A value of zero indicates that the
alternate destination is not used."
::= { pktSwchChannelSEntry 8 }
pktSwchChannelAutocallRetriesS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of autocall retries if the autocall setup request is
rejected with a busy cause."
::= { pktSwchChannelSEntry 9 }
pktSwchChannelAutocallIntervalS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interval in seconds between consecutive autocall retries."
::= { pktSwchChannelSEntry 10 }
pktSwchChannelCallAliasS OBJECT-TYPE
SYNTAX Integer32 (0..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The alias to be sent after the call is set up. A value of zero
indicates that alias sending is disabled. The aliases are
configured on the Alias Table."
::= { pktSwchChannelSEntry 11 }
pktSwchChannelSubAddress1S OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The first subaddress for the channel."
::= { pktSwchChannelSEntry 12 }
pktSwchChannelSubAddress2S OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The second subaddress for the channel."
::= { pktSwchChannelSEntry 13}
pktSwchChannelNUISEntry OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number corresponding to the NUI information to be sent.
This number is the same as the pktSwchNuiGroupId."
::= { pktSwchChannelSEntry 14 }
pktSwchChannelClearTimerS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time limitation for an open session. A value of zero indicates that
the Clear timer is not used."
::= { pktSwchChannelSEntry 15 }
pktSwchChannelOptionsS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls the use of gneral non-correlated channel options.
The value is a sum of values (powers of two), where each value in
the sum represents an option.
The values that may be included in the sum and their meanings are:
0 No options
1 HW signal is checked
2 Auto call after clear
4 Auto call after <CR>
8 DCD is ON, only in DATA TRANSFER mode
16 Charging Info Facility
32 Auto call if HW signal is set
64 Accept calls even if HW signal is is OFF
128 A transparent channel."
::= { pktSwchChannelSEntry 16 }
pktSwchChannelClear OBJECT-TYPE
SYNTAX INTEGER {
noOp(1),
clear(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Clearing Channel operation disconnects all sessions"
::= { pktSwchChannelSEntry 17 }
pktSwchChannelCopyTo OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination channel number, to which the Copy
is performed."
::= { pktSwchChannelSEntry 18 }
pktSwchChannelCopyToWMask OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination channel number, to which the Copy with Mask
is performed."
::= { pktSwchChannelSEntry 19 }
pktSwchChannelCopyMask OBJECT-TYPE
SYNTAX Integer32 (0..16383)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The selected configuration parameters to be copied from the source
channel to the target channels. The value is a sum of values
(powers of two), where each value in the sum represents a selected
parameter that is not copied. The values that may be included in the
sum and their meanings are:
0 Copy all.
1 Do not copy Profile.
2 Do not copy OutCallProfile.
4 Do not copy InCallProfile.
8 Do not copy RemoteProfile.
16 Do not copy AutocallId.
32 Do not copy AlterCallId.
64 Do not copy AutoCallRetries.
128 Do not copy AutoCallInterval.
256 Do not copy CallAlias.
512 Do not copy SubAddress1.
1024 Do not copy SubAddress2.
2048 Do not copy NUIEntry.
4096 Do not copy ClearTimer.
8192 Do not copy Options.
XXX - Any combination of the above."
::= { pktSwchChannelSEntry 20 }
pktSwchChannelATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchChannelAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Active Channel Table defines the channels configured on the PS."
::= { pktSwchChannel 2 }
pktSwchChannelAEntry OBJECT-TYPE
SYNTAX PktSwchChannelAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the Active Channel
Table."
INDEX { pktSwchChannelIfIndexA }
::= { pktSwchChannelATable 1 }
PktSwchChannelAEntry ::= SEQUENCE {
pktSwchChannelIfIndexA
Integer32,
pktSwchChannelNumberA
Integer32,
pktSwchChannelProfileA
Integer32,
pktSwchChannelOutCallProfileA
Integer32,
pktSwchChannelInCallProfileA
Integer32,
pktSwchChannelRemoteProfileA
Integer32,
pktSwchChannelAutocallIdA
Integer32,
pktSwchChannelAlterAutocallIdA
Integer32,
pktSwchChannelAutocallRetriesA
Integer32,
pktSwchChannelAutocallIntervalA
Integer32,
pktSwchChannelCallAliasA
Integer32,
pktSwchChannelSubAddress1A
Integer32,
pktSwchChannelSubAddress2A
Integer32,
pktSwchChannelNUIAEntry
Integer32,
pktSwchChannelClearTimerA
Integer32,
pktSwchChannelOptionsA
Integer32
}
pktSwchChannelIfIndexA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is used as the index for the channel table."
::= { pktSwchChannelAEntry 1 }
pktSwchChannelNumberA OBJECT-TYPE
SYNTAX Integer32 (1..288)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number by which a channel is identified."
::= { pktSwchChannelAEntry 2 }
pktSwchChannelProfileA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The profile that the channel uses for command mode operations."
::= { pktSwchChannelAEntry 3 }
pktSwchChannelOutCallProfileA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the profile that is used during an outgoing call on the channel."
::= { pktSwchChannelAEntry 4 }
pktSwchChannelInCallProfileA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the profile that is used during an incoming call on the channel."
::= { pktSwchChannelAEntry 5 }
pktSwchChannelRemoteProfileA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the profile that is downloaded to the remote PAD at the beginning of
a new call."
::= { pktSwchChannelAEntry 6 }
pktSwchChannelAutocallIdA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the mnemonic (call ID) to be used as the first alternative. A value of zero indicates that
the autocall function is disabled."
::= { pktSwchChannelAEntry 7 }
pktSwchChannelAlterAutocallIdA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the alternate mnemonic for the autocall function. A value of zero indicates that the
alternate destination is not used."
::= { pktSwchChannelAEntry 8 }
pktSwchChannelAutocallRetriesA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of autocall retrues if the autocall setup request is rejected with a busy cause."
::= { pktSwchChannelAEntry 9 }
pktSwchChannelAutocallIntervalA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interval in seconds between consecutive autocall retries."
::= { pktSwchChannelAEntry 10 }
pktSwchChannelCallAliasA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alias to be sent after the call is set up. A value of zero indicates that alias
sending is disabled. The aliases are configured on the Alias Table."
::= { pktSwchChannelAEntry 11 }
pktSwchChannelSubAddress1A OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The first subaddress for the channel."
::= { pktSwchChannelAEntry 12 }
pktSwchChannelSubAddress2A OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The second subaddress for the channel."
::= { pktSwchChannelAEntry 13}
pktSwchChannelNUIAEntry OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number corresponding to the NUI information to be sent. This number is the same as the
pktSwchNuiIndex."
::= { pktSwchChannelAEntry 14 }
pktSwchChannelClearTimerA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time limitation for an open session. A value of zero indicates that the Clear timer is not used."
::= { pktSwchChannelAEntry 15 }
pktSwchChannelOptionsA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This controls the use of general non-correlated channel options. The value is a sum of values
(powers of two), where each value in the sum represents an option.
The values that may be included in the sum and their meanings are:
0 No options
1 RTS line checked
2 Auto call after clear
4 Auto call after <CR>
8 DCD is ON, only in DATA TRANSFER mode.
16 Charging Info Facility
32 Auto call if HW signal is set
64 Accept calls even if HW signal is is OFF
128 A transparent channel."
::= { pktSwchChannelAEntry 16 }
-- pktSwchCallId defines the Call IDs
pktSwchCallId OBJECT IDENTIFIER ::= { pktSwchAsync 3 }
-- pktSwchCallIdSTable defines the Scratch Call IDs
pktSwchCallIdSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchCallIdSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Call ID Table S defines the Scratch Call IDs configured on the device."
::= { pktSwchCallId 1 }
pktSwchCallIdSEntry OBJECT-TYPE
SYNTAX PktSwchCallIdSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the Scratch CallId Table."
INDEX { pktSwchCallIdNumberS }
::= { pktSwchCallIdSTable 1 }
PktSwchCallIdSEntry ::= SEQUENCE {
pktSwchCallIdNumberS
Integer32,
pktSwchCallIdMnemonicS
DisplayString,
pktSwchCallIdAddressS
DisplayString,
pktSwchCallIdStatusS
INTEGER
}
pktSwchCallIdNumberS OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of this entry."
::= { pktSwchCallIdSEntry 1 }
pktSwchCallIdMnemonicS OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The mnemonic for this call ID."
::= { pktSwchCallIdSEntry 2 }
pktSwchCallIdAddressS OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The address for this call ID."
::= { pktSwchCallIdSEntry 3 }
pktSwchCallIdStatusS OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this Call ID table entry. The choices are those defined in the SNMPv2 Textual
Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with
the RowStatus textual convention SYNTAX."
::= { pktSwchCallIdSEntry 4 }
-- pktSwchCallIdATable defines the Active Call IDs
pktSwchCallIdATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchCallIdAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Call ID Table A defines the Active Call IDs configured on the device."
::= { pktSwchCallId 2 }
pktSwchCallIdAEntry OBJECT-TYPE
SYNTAX PktSwchCallIdAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the Active CallId Table."
INDEX { pktSwchCallIdNumberA }
::= { pktSwchCallIdATable 1 }
PktSwchCallIdAEntry ::= SEQUENCE {
pktSwchCallIdNumberA
Integer32,
pktSwchCallIdMnemonicA
DisplayString,
pktSwchCallIdAddressA
DisplayString
}
pktSwchCallIdNumberA OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of this entry."
::= { pktSwchCallIdAEntry 1 }
pktSwchCallIdMnemonicA OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mnemonic for this call ID."
::= { pktSwchCallIdAEntry 2 }
pktSwchCallIdAddressA OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The address for this call ID."
::= { pktSwchCallIdAEntry 3 }
-- pktSwchAlias defines the Aliases
pktSwchAlias OBJECT IDENTIFIER ::= { pktSwchAsync 4 }
-- pktSwchAliasSTable defines the Scratch Aliases
pktSwchAliasSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchAliasSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Alias Table defines the aliases configured on the device."
::= { pktSwchAlias 1 }
pktSwchAliasSEntry OBJECT-TYPE
SYNTAX PktSwchAliasSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the Alias Table."
INDEX { pktSwchAliasNumberS }
::= { pktSwchAliasSTable 1 }
PktSwchAliasSEntry ::= SEQUENCE {
pktSwchAliasNumberS
Integer32,
pktSwchAliasValueS
DisplayString,
pktSwchAliasStatusS
INTEGER
}
pktSwchAliasNumberS OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of this entry."
::= { pktSwchAliasSEntry 1 }
pktSwchAliasValueS OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The alias is defined using up to 64 characters."
::= { pktSwchAliasSEntry 2 }
pktSwchAliasStatusS OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this Alias table entry. The choices are those defined in the SNMPv2 Textual
Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with
the RowStatus textual convention SYNTAX."
::= { pktSwchAliasSEntry 3 }
-- pktSwchAliasATable defines the Active Aliases
pktSwchAliasATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchAliasAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Alias Table defines the aliases configured on the device."
::= { pktSwchAlias 2 }
pktSwchAliasAEntry OBJECT-TYPE
SYNTAX PktSwchAliasAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the Alias Table."
INDEX { pktSwchAliasNumberA }
::= { pktSwchAliasATable 1 }
PktSwchAliasAEntry ::= SEQUENCE {
pktSwchAliasNumberA
Integer32,
pktSwchAliasValueA
DisplayString
}
pktSwchAliasNumberA OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of this entry."
::= { pktSwchAliasAEntry 1 }
pktSwchAliasValueA OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alias is defined using up to 64 characters."
::= { pktSwchAliasAEntry 2 }
-- The pktSwchAsyncStatTable contains status information and statistics
-- for the Async channels
pktSwchAsyncStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchAsyncStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The AsyncStat Table includes status information and statistics
provided by the PS on the async channels."
::= { pktSwchAsync 5 }
pktSwchAsyncStatEntry OBJECT-TYPE
SYNTAX PktSwchAsyncStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the Async Stat Table."
INDEX { pktSwchAsyncIfIndex }
::= { pktSwchAsyncStatTable 1 }
PktSwchAsyncStatEntry ::= SEQUENCE {
pktSwchAsyncIfIndex
Integer32,
pktSwchAsyncChannelNumber
Integer32,
pktSwchAsyncConnectionStatus
INTEGER,
pktSwchAsyncNumLogChannels
Integer32,
pktSwchAsyncNumActSessions
Integer32,
pktSwchAsyncAutocallId
Integer32,
pktSwchAsyncRTSStatus
INTEGER,
pktSwchAsyncBuffToNet
Integer32,
pktSwchAsyncBuffToUser
Integer32,
pktSwchAsyncTxXoff
INTEGER,
pktSwchAsyncRxXoff
INTEGER,
pktSwchAsyncBuffOutstand
Integer32,
pktSwchAsyncChannelMode
INTEGER
}
pktSwchAsyncIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index for the table."
::= { pktSwchAsyncStatEntry 1 }
pktSwchAsyncChannelNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The channel to which this entry applies. This value is the
same as the pktSwchChannelNumber."
::= { pktSwchAsyncStatEntry 2 }
pktSwchAsyncConnectionStatus OBJECT-TYPE
SYNTAX INTEGER {
engaged(1),
free (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The connection status of the channel is either FREE or ENG (engaged)."
::= { pktSwchAsyncStatEntry 3}
pktSwchAsyncNumLogChannels OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of active logical channels used by the asynchronous channel."
::= { pktSwchAsyncStatEntry 4 }
pktSwchAsyncNumActSessions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of active sessions opened by this asynchronous channel."
::= { pktSwchAsyncStatEntry 5 }
pktSwchAsyncAutocallId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the channel has been configured to use the autocall function and
what is the call ID. NONE means that the channel is not configured for autocall."
::= { pktSwchAsyncStatEntry 6}
pktSwchAsyncRTSStatus OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
off (2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shows the status of the RTS line of the asynchronous channel.
OFF indicates that the RTS line is not active, ON indicates that
it is active, and UNUSED indicates that the channel PAD is
programmed to disregard the state of the RTS line."
::= { pktSwchAsyncStatEntry 7 }
pktSwchAsyncBuffToNet OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data buffers currently used by the transmit direction of the channel."
::= { pktSwchAsyncStatEntry 8 }
pktSwchAsyncBuffToUser OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data buffers currently used by the receive direction of the channel."
::= { pktSwchAsyncStatEntry 9}
pktSwchAsyncTxXoff OBJECT-TYPE
SYNTAX INTEGER {
no (1),
yes(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of software flow control in the transmit direction.
NO indicates that traffic flow is enabled. YES indicates that traffic
flow from the user's DTE to the device channel has been interrupted
by sending the X-OFF character to the DTE."
::= { pktSwchAsyncStatEntry 10 }
pktSwchAsyncRxXoff OBJECT-TYPE
SYNTAX INTEGER {
no (1),
yes(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of software flow control in the receive direction.
NO indicates that traffic flow is enabled. YES indicates that traffic
flow to the user's DTE from the device channel has been interrupted
by means of the X-OFF character."
::= { pktSwchAsyncStatEntry 11 }
pktSwchAsyncBuffOutstand OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of buffers which were sent to the async user
but weren't yet freed."
::= { pktSwchAsyncStatEntry 12 }
pktSwchAsyncChannelMode OBJECT-TYPE
SYNTAX INTEGER {
none (1),
activeLink (2),
x28command (3),
dataTransfer(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The channel mode is either X28 COMMAND or DATA TRANSFER."
::= { pktSwchAsyncStatEntry 13 }
-- The pktSwchAsyncRunProTable contains status information and statistics for the Async channels
pktSwchAsyncRunProTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchAsyncRunProEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The AsyncRunPro Table includes status information and statistics provided by the PS
on the async channels."
::= { pktSwchAsync 6 }
pktSwchAsyncRunProEntry OBJECT-TYPE
SYNTAX PktSwchAsyncRunProEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the Async RunPro Table."
INDEX { pktSwchAsyncRunProIfIndex }
::= { pktSwchAsyncRunProTable 1 }
PktSwchAsyncRunProEntry ::= SEQUENCE {
pktSwchAsyncRunProIfIndex
Integer32,
pktSwchAsyncRunProChannelNumber
Integer32,
pktSwchAsyncRunProRecallChar
Integer32,
pktSwchAsyncRunProEcho
INTEGER,
pktSwchAsyncRunProDataForwChar
Integer32,
pktSwchAsyncRunProIdleTimer
Integer32,
pktSwchAsyncRunProDevFlowCont
INTEGER,
pktSwchAsyncRunProServSig
INTEGER,
pktSwchAsyncRunProBreak
Integer32,
pktSwchAsyncRunProDiscOut
INTEGER,
pktSwchAsyncRunProCRPPadding
Integer32,
pktSwchAsyncRunProLineFold
Integer32,
pktSwchAsyncRunProSpeed
INTEGER,
pktSwchAsyncRunProPadFlowCont
INTEGER,
pktSwchAsyncRunProLineFeedInsert
INTEGER,
pktSwchAsyncRunProLineFeedPad
Integer32,
pktSwchAsyncRunProEditing
INTEGER,
pktSwchAsyncRunProCharDel
Integer32,
pktSwchAsyncRunProLineDel
Integer32,
pktSwchAsyncRunProLineDisp
Integer32,
pktSwchAsyncRunProEditServSig
Integer32,
pktSwchAsyncRunProEchomask
Integer32,
pktSwchAsyncRunProParTreat
INTEGER,
pktSwchAsyncRunProPageWait
Integer32
}
pktSwchAsyncRunProIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index for the table."
::= { pktSwchAsyncRunProEntry 1 }
pktSwchAsyncRunProChannelNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The channel to which this entry applies. This value is the same as the pktSwchChannelNumber."
::= { pktSwchAsyncRunProEntry 2 }
pktSwchAsyncRunProRecallChar OBJECT-TYPE
SYNTAX Integer32 (0..126)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The character specified by this entry is used to escape from the data transfer
mode and enter the PAD command mode. The integer values have the following meanings:
(0) PAD recall is not possible
(1) The PAD recall character is DLE
(2) to (126) The PAD recall character is specified by the user by entering its ASCII
code."
::= { pktSwchAsyncRunProEntry 3 }
pktSwchAsyncRunProEcho OBJECT-TYPE
SYNTAX INTEGER {
echEn(1),
noEch(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This determines if an echo of the input characters is retured to the DTE.
The options are either 'echo enabled' or 'no echo'."
::= { pktSwchAsyncRunProEntry 4 }
pktSwchAsyncRunProDataForwChar OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value is a sum of values (powers of two), where each value in the sum represents
a character (or characters) that is (are) used as a data forwarding character. The data
forwarding characters are used to instruct the PAD to complete the assembly of and to
forward a packet containing the data accumulated up to the reception of such a character.
The values that may be included in the sum and their meanings are:
0 Data forwarding characters are not used
1 Alpha-numeric characters (A to Z, a to z, 0 to 9, inclusive)
2 Character CR
4 Characters ESC, BEL, ENQ, ACK
8 Characters DEL, CAN, DC2
16 Characters EOT, ETX
32 Characters HT, LF, VT, FF
64 All the other characters in colums 0 and 1 of IA5 and not listed above."
::= { pktSwchAsyncRunProEntry 5 }
pktSwchAsyncRunProIdleTimer OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packets will be forwarded when the idle timer expires. The idle time interval is specified
as a multiple of 50 milliseconds. The multiple is given by the parameter value. For example,
a value of 60 sets an interval of 3 seconds. If the parameter value is 0, no forwarding occurs
after the idle condition."
::= { pktSwchAsyncRunProEntry 6 }
pktSwchAsyncRunProDevFlowCont OBJECT-TYPE
SYNTAX INTEGER {
trans(1),
transAndCom(2),
noFlow(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter determines whether or not the PAD uses software flow control for the
attached device. The options are either (1) PAD uses flow control during data transfer
mode, (2) PAD uses flow control both in the data transfer mode and in the command mode,
or (255) PAD does not use flow control."
::= { pktSwchAsyncRunProEntry 7 }
pktSwchAsyncRunProServSig OBJECT-TYPE
SYNTAX INTEGER {
serv(1),
prompt(4),
servAndPrompt(5),
noSig(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter is used to instruct the PAD whether to transfer PAD service signals and
the PAD prompt to the local DTE in standard format. The options are (1) PAD service
signals are transmitted to the DTE using the standard format, (4) The PAD prompt is
transmitted using the standard format, (5) PAD service signals and the PAD prompt are
transmitted in the standard format, or (255) No PAD service signals are transmitted to the
DTE."
::= { pktSwchAsyncRunProEntry 8 }
pktSwchAsyncRunProBreak OBJECT-TYPE
SYNTAX Integer32 (0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value is a sum of values (powers of two), where each value in the sum represents
a PAD operation on receipt of the break signal from the DTE.
The values that may be included in the sum and their meanings are:
0 Nothing
1 Send interrupt packet to network
2 Send RESET packet to network
4 Send and 'indication of break' message
8 Escape from data transfer mode
16 Discard output data waiting to be sent to the DTE ."
::= { pktSwchAsyncRunProEntry 9 }
pktSwchAsyncRunProDiscOut OBJECT-TYPE
SYNTAX INTEGER {
discOut(1),
normal(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter instructs the PAD whether to forward the user sequences included in
data packets to the local DTE or discard them. The options are (1) discard output or
(2) normal data delivery. If the value of radSPSProfileBreak is 21, the value of
pktSwchAsyncRunProDiscOut is automatically set to (1) when a break signal is received."
::= { pktSwchAsyncRunProEntry 10 }
pktSwchAsyncRunProCRPPadding OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter specifies the number of padding characters to be added after a carriage
return character is transmitted to the local DTE."
::= { pktSwchAsyncRunProEntry 11}
pktSwchAsyncRunProLineFold OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter specifies the maximum number of characters to be inserted before the
format effector. If the value is zero, there is no insertion of a format effector (line folding)."
::= { pktSwchAsyncRunProEntry 12}
pktSwchAsyncRunProSpeed OBJECT-TYPE
SYNTAX INTEGER {
s110bps(1),
s300bps(2),
s1200bps(3),
s600bps(4),
s75bps(5),
s150bps(6),
s2400bps(12),
s4800bps(13),
s9600bps(14),
s19200bps(15),
s38400bps(19),
s57600bps(20),
s115200bps(21)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter determines the rate of data transmission to and from the DTE."
::= { pktSwchAsyncRunProEntry 13 }
pktSwchAsyncRunProPadFlowCont OBJECT-TYPE
SYNTAX INTEGER {
flowCont(1),
noFlowCont(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This determines whether or not the terminal can exercise flow control over the PAD.
The options are either 'device can exercise flow control' or 'device cannot exercise flow
control."
::= { pktSwchAsyncRunProEntry 14 }
pktSwchAsyncRunProLineFeedInsert OBJECT-TYPE
SYNTAX INTEGER {
afterCR(1),
recCR(2),
echoCR(4),
onePlusFour(5),
twoPlusFour(6),
oneTwoFour(7),
noFeed(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates when there is a line feed insertion after CR. The options are
(1) Insert line feed after transmission of CR to the DTE, (2) Insert line feed after receipt
of CR from the DTE, (4) Insert line feed after echoing a CR character to the DTE,
(5) Combination of (1) and (4), (6) Insert line feed after any CR to the DTE (combination of
(2) and (4)), (7) Combination of (1), (2), and (4), or (255) No line feed insertion."
::= { pktSwchAsyncRunProEntry 15 }
pktSwchAsyncRunProLineFeedPad OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter specifies the number of padding characters to be added after a line
feed."
::= { pktSwchAsyncRunProEntry 16 }
pktSwchAsyncRunProEditing OBJECT-TYPE
SYNTAX INTEGER {
edit(1),
noEdit(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter specifies the editing capabilities available in the data transfer mode.
Editing is always possible when the PAD is in the command mode. The options are
(1) Command editing in the data trasfer mode is enabled or (2) No command editing
in the data transfer mode."
::= { pktSwchAsyncRunProEntry 17 }
pktSwchAsyncRunProCharDel OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter specifies the character delete, which is one character from IA5. The default
selection is 127 (character DEL)."
::= { pktSwchAsyncRunProEntry 18}
pktSwchAsyncRunProLineDel OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter specifies the line delete, which is one character from IA5. The default
selection is 24 (character CAN)."
::= { pktSwchAsyncRunProEntry 19}
pktSwchAsyncRunProLineDisp OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the line display character, which is one character
from IA5. The default selection is 18 (character DC2)."
::= { pktSwchAsyncRunProEntry 20}
pktSwchAsyncRunProEditServSig OBJECT-TYPE
SYNTAX Integer32 (0..126)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the editing PAD service signals.
The integer values have the following meanings:
(0) No editing PAD service signals
(1) Editing PAD service signals for printing terminals
(2) Editing PAD service signals for display terminals
(3) to (126) Editing PAD service signals using the desired character from IA5."
::= { pktSwchAsyncRunProEntry 21 }
pktSwchAsyncRunProEchomask OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value is a sum of values (powers of two), where each value in the sum represents
a character (or characters) that is (are) included in the echo mask. The characters in the
echo mask are not echoed to the DTE when PAD echo is enabled.
The values that may be included in the sum and their meanings are:
0 No echo mask (all the characters are echoed)
1 No echo of character CR
2 No echo of character LF
4 No echo of characters VT, HT, FF
8 No echo of characters BEL, BS
16 No echo of characters ESC, ENQ
32 No echo of characters ACK, NAK, STX, SOH, EOT, ETB, ETX
64 No echo of the editing characters selected by radSPSProfileCharDel,
radSPSProfileLineDel, and
radSPSProfileLineDisp
128 No echo of the DEL character and of all the other characters in the range of
ASCII 00 through 31 not mentioned above."
::= { pktSwchAsyncRunProEntry 22 }
pktSwchAsyncRunProParTreat OBJECT-TYPE
SYNTAX INTEGER {
parCheck(1),
parGen(2),
checkAndGen(3),
noPar(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry controls the generation of parity bits in the data sent to the local DTE and the
checking of the parity bit when generated by the local DTE. The options are (1) parity
checking is enabled, (2) parity generation is enabled, (3) parity checking and generation are
enabled, or (255) no parity checking nor parity generation."
::= { pktSwchAsyncRunProEntry 23 }
pktSwchAsyncRunProPageWait OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the number of line feed characters counted by the PAD before the
page wait condition is entered. If the value is zero, page wait is disabled."
::= { pktSwchAsyncRunProEntry 24}
-- pktSwch defines the scratch and active PhyInterface configurations of
-- the PS
pktSwchPhyInterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchPhyInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Link Table defines the links configured on the PS."
::= { radPS 3 }
pktSwchPhyInterfaceEntry OBJECT-TYPE
SYNTAX PktSwchPhyInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the Link Table."
INDEX { pktSwchPhyInterfaceIfIndex }
::= { pktSwchPhyInterfaceTable 1 }
PktSwchPhyInterfaceEntry ::= SEQUENCE {
pktSwchPhyInterfaceIfIndex
Integer32,
pktSwchPhyInterfaceProtocolS
INTEGER,
pktSwchPhyInterfaceProtocolA
INTEGER,
pktSwchPhyInterfaceCopyTo
Integer32,
pktSwchPhyInterfaceChanged
INTEGER,
pktSwchPhyInterfaceRxBuffInPool
Integer32,
pktSwchPhyInterfaceConnector
INTEGER,
pktSwchPhyInterfaceNeighborIp
IpAddress,
pktSwchPhyInterfaceProtocolStatus
INTEGER,
pktSwchPhyInterfaceTestCmd
INTEGER,
pktSwchPhyInterfaceTestTransmittedFrames
Counter32,
pktSwchPhyInterfaceTestReceivedFrames
Counter32,
pktSwchPhyInterfaceTestLostFrames
Integer32
}
pktSwchPhyInterfaceIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex identified with this link."
::= { pktSwchPhyInterfaceEntry 1 }
pktSwchPhyInterfaceProtocolS OBJECT-TYPE
SYNTAX INTEGER {
x25(1),
frameRelay(2),
hdlc(3),
sdlc(4),
async(5),
stm4(6),
stm8(7),
stm16(8),
stm24(9),
mpe(10),
bscHpad(11),
bscTpad(12),
slip(13),
ethernet(14),
ppp(15)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The protocol to be used on this link.
Note for PPP:
PPP protocol is allowed to be applied on Sync Links (1-3)
as well as Async channels (1-24).
In order to eliminate ambiguity in the IP destination where
a destination of P1 can be used for example for async channel 1
and Sync Link 1, it was decided NOT TO ALLOW configuring PPP on both
Sync Link no. 1 and async channel 1. Same for Link 2 and
Link 3."
::= { pktSwchPhyInterfaceEntry 2 }
pktSwchPhyInterfaceProtocolA OBJECT-TYPE
SYNTAX INTEGER {
x25(1),
frameRelay(2),
hdlc(3),
sdlc(4),
async(5),
stm4(6),
stm8(7),
stm16(8),
stm24(9),
mpe(10),
bscHpad(11),
bscTpad(12),
slip(13),
ethernet(14),
ppp(15)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The protocol currently used on this link."
::= { pktSwchPhyInterfaceEntry 3 }
pktSwchPhyInterfaceCopyTo OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination interface number, to which the Copy
is performed."
::= { pktSwchPhyInterfaceEntry 4 }
pktSwchPhyInterfaceChanged OBJECT-TYPE
SYNTAX INTEGER {
no (2),
yes (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if the current running protocol is different than the defined
protocol"
::= { pktSwchPhyInterfaceEntry 5 }
pktSwchPhyInterfaceRxBuffInPool OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The free data buffers in the Rx pool per interface"
::= { pktSwchPhyInterfaceEntry 6 }
pktSwchPhyInterfaceConnector OBJECT-TYPE
SYNTAX INTEGER {
v24(2),
v35(3),
x21(4),
rs530(5),
acd(6),
mobi(7),
u(8),
etherUtp(9),
noConnector(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The connector type of the interface"
::= { pktSwchPhyInterfaceEntry 7 }
pktSwchPhyInterfaceNeighborIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Ip address of the device on the other side of the link."
::= { pktSwchPhyInterfaceEntry 8 }
pktSwchPhyInterfaceProtocolStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of the Interface Protocol row in the Table."
::= { pktSwchPhyInterfaceEntry 9 }
pktSwchPhyInterfaceTestCmd OBJECT-TYPE
SYNTAX INTEGER {
noOp (1),
v54Local (2),
v54Remote(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"START/STOP a test on the current interface.
The available tests are:
v54Local - Local Analog Loopback (AL), L3 according to ITU-T standard.
v54Remote - Remote Digital Loopback(RDL), L2 according to ITU-T standard.
For stopping the test, SET the noOp (1) option. "
::= { pktSwchPhyInterfaceEntry 10 }
pktSwchPhyInterfaceTestTransmittedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"No. of frames which were transmitted from this interface
during the TEST."
::= { pktSwchPhyInterfaceEntry 11 }
pktSwchPhyInterfaceTestReceivedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"No. of frames which were received on this interface
during the TEST."
::= { pktSwchPhyInterfaceEntry 12 }
pktSwchPhyInterfaceTestLostFrames OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of the frames which were lost during the TEST."
::= { pktSwchPhyInterfaceEntry 13 }
-- The PS X.25 Group contains the Lapb Table, the PLP Table
pktSwchx25 OBJECT IDENTIFIER ::= { radPS 4 }
pktSwchLapb OBJECT IDENTIFIER ::= { pktSwchx25 1 }
-- The PS Lapb Scratch Table
pktSwchLapbSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchLapbSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Lapb Table includes statistics and configurable objects
provided by the PS that are not included in RFC 1381."
::= { pktSwchLapb 1 }
pktSwchLapbSEntry OBJECT-TYPE
SYNTAX PktSwchLapbSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the RAD Lapb Table."
INDEX { pktSwchLapbLinkNumberS }
::= { pktSwchLapbSTable 1 }
PktSwchLapbSEntry ::= SEQUENCE {
pktSwchLapbLinkNumberS
Integer32,
pktSwchLapbInternalClockS
INTEGER,
pktSwchLapbLineOptionS
Integer32,
pktSwchLapbSegmentSizeS
Integer32,
pktSwchLapbXIDS
Integer32,
pktSwchLapbAckCounterS
Integer32,
pktSwchLapbAckTimerS
Integer32
}
pktSwchLapbLinkNumberS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link number with which this entry is associated. This value
corresponds to pktSwchPhyInterfaceNumber. There is an entry for
each link for which the pktSwchPhyInterfaceProtocol is X.25 and one
entry for each link and DLCI if the pktSwchPhyInterfaceProtocol for
the link is Frame Relay and the DLCI is defined as using X.25."
::= { pktSwchLapbSEntry 1 }
pktSwchLapbInternalClockS OBJECT-TYPE
SYNTAX INTEGER {
r2400bps (1),
r4800bps (2),
r9600bps (3),
r14400bps(4),
r19200bps(5),
r38400bps(6),
r48Kbps (7),
r56Kbps (8),
r64Kbps (9),
r128Kbps (10),
r256Kbps (11),
r384Kbps (12),
r504Kbps (13),
r768Kbps (14),
r1008Kbps(15),
r1466Kbps(16),
r2016Kbps(17),
external(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The internal clock speed to be used on this LAPB link. If external clock is used, the value is
255."
::= { pktSwchLapbSEntry 2 }
pktSwchLapbLineOptionS OBJECT-TYPE
SYNTAX Integer32 (0..2048)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The line option to be used on this link. A value of zero indicates
no options. A value between 0 and 255 inclusive specifes a time in
minutes after which the line will be disconnected if no session is open.
The following values have the associated meanings:
256 Dialed line
512 Return to leased line
1024 DTR is ON permanent
2048 DTR is OFF permanent.
any valid combination of the above options should be represented as
a sum of the corresponding values. Valid combinations are:
DTR ON or OFF (but not both). Dialed line options or not applicable.
If DTR control is on (256), then all combinations are possible
except 1024 and 2048 (which are not possible)."
::= { pktSwchLapbSEntry 3 }
pktSwchLapbSegmentSizeS OBJECT-TYPE
SYNTAX Integer32 (1..4096)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value is for the use of billing information. The value can be no larger than the maximum
packet size."
::= { pktSwchLapbSEntry 4 }
pktSwchLapbXIDS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this parameter is different than zero, this lapb is configured
as a V25 bis dialed link. This is the XID entry Index which this dialed link is
associated with."
::= { pktSwchLapbSEntry 5 }
pktSwchLapbAckCounterS OBJECT-TYPE
SYNTAX Integer32 (1..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines how many frames will be received on the link
before the PS will send Acknowledge (RR frame).
It is used for Piggy Back Acknowledge (ack within the info frames)
and saves traffic on the line.
Default value: 1 ."
::= { pktSwchLapbSEntry 6 }
pktSwchLapbAckTimerS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Ack Timer defines the maximum time in seconds that the device
will wait before sending RR acknowledgment on the received frames.
It is used for Piggy Back Acknowledge (ack within the info frames)
and saves traffic on the line.
Default value: 0 ."
::= { pktSwchLapbSEntry 7 }
-- The PS Lapb Active Table
pktSwchLapbATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchLapbAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Lapb Table includes statistics and configurable objects provided
by the PS that are not included in RFC 1381."
::= { pktSwchLapb 2 }
pktSwchLapbAEntry OBJECT-TYPE
SYNTAX PktSwchLapbAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the RAD Lapb Table."
INDEX { pktSwchLapbLinkNumberA }
::= { pktSwchLapbATable 1 }
PktSwchLapbAEntry ::= SEQUENCE {
pktSwchLapbLinkNumberA
Integer32,
pktSwchLapbInternalClockA
INTEGER,
pktSwchLapbLineOptionA
Integer32,
pktSwchLapbSegmentSizeA
Integer32,
pktSwchLapbLineProtocol
INTEGER,
pktSwchLapbLowerId
Integer32,
pktSwchLapbXIDA
Integer32,
pktSwchLapbTransmittedIFrames
Counter32,
pktSwchLapbReceivedIFrames
Counter32,
pktSwchLapbNSError
Counter32,
pktSwchLapbTransmittedRRFrames
Counter32,
pktSwchLapbReceivedRRFrames
Counter32,
pktSwchLapbTransmittedRNRFrames
Counter32,
pktSwchLapbReceivedRNRFrames
Counter32,
pktSwchLapbTransmittedFRMRFrames
Counter32,
pktSwchLapbReceivedFRMRFrames
Counter32,
pktSwchLapbAckCounterA
Integer32,
pktSwchLapbAckTimerA
Integer32
}
pktSwchLapbLinkNumberA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link number with which this entry is associated. This value corresponds to
pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is
X.25 and one entry for each link and DLCI if the pktSwchPhyInterfaceProtocol for the link is Frame
Relay and theDLCI is defined as using X.25."
::= { pktSwchLapbAEntry 1 }
pktSwchLapbInternalClockA OBJECT-TYPE
SYNTAX INTEGER {
r2400bps (1),
r4800bps (2),
r9600bps (3),
r14400bps(4),
r19200bps(5),
r38400bps(6),
r48Kbps (7),
r56Kbps (8),
r64Kbps (9),
r128Kbps (10),
r256Kbps (11),
r384Kbps (12),
r504Kbps (13),
r768Kbps (14),
r1008Kbps(15),
r1466Kbps(16),
r2016Kbps(17),
external(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The internal clock speed currently used on this LAPB link.
If external clock is used, the value is 255."
::= { pktSwchLapbAEntry 2 }
pktSwchLapbLineOptionA OBJECT-TYPE
SYNTAX Integer32 (0..2048)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The line option currently used on this link. A value of zero
indicates no options. A value between 1 and 255 inclusive specifes
a time in minutes after which the line will be disconnected if no
session is open. The following values have the associated meanings:
256 Dialed line
512 Return to leased line
1024 DTR is ON permanent
2048 DTR is OFF permanent.
any valid combination of the above options should be represented as
a sum of the corresponding values. Valid combinations are:
DTR ON or OFF (but not both). Dialed line options or not applicable.
If DTR control is on (256), then all combinations are possible
except 1024 and 2048 (which are not possible)."
::= { pktSwchLapbAEntry 3 }
pktSwchLapbSegmentSizeA OBJECT-TYPE
SYNTAX Integer32 (1..4096)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current value of the segment size."
::= { pktSwchLapbAEntry 4 }
pktSwchLapbLineProtocol OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
x25 (2),
fr (3),
isdn (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the lower level protocol which runs under this lapb interface."
::= { pktSwchLapbAEntry 5 }
pktSwchLapbLowerId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"In case of X.25 over Frame-relay this is the lower level link
number."
::= { pktSwchLapbAEntry 6 }
pktSwchLapbXIDA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When this parameter is different than zero, this lapb is configured
as a V25 bis dialed link. This is the XID entry which this dialed link is
associated with."
::= { pktSwchLapbAEntry 7 }
pktSwchLapbTransmittedIFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmitted I frames on this link."
::= { pktSwchLapbAEntry 8 }
pktSwchLapbReceivedIFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The received I frames on this link."
::= { pktSwchLapbAEntry 9 }
pktSwchLapbNSError OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of I frames transmitted out of sequence."
::= { pktSwchLapbAEntry 10 }
pktSwchLapbTransmittedRRFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmitted RR frames on this link."
::= { pktSwchLapbAEntry 11 }
pktSwchLapbReceivedRRFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The received RR frames on this link."
::= { pktSwchLapbAEntry 12 }
pktSwchLapbTransmittedRNRFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmitted RNR frames on this link."
::= { pktSwchLapbAEntry 13 }
pktSwchLapbReceivedRNRFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The received RNR frames on this link."
::= { pktSwchLapbAEntry 14 }
pktSwchLapbTransmittedFRMRFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmitted FRMR frames on this link."
::= { pktSwchLapbAEntry 15 }
pktSwchLapbReceivedFRMRFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The received FRMR frames on this link."
::= { pktSwchLapbAEntry 16 }
pktSwchLapbAckCounterA OBJECT-TYPE
SYNTAX Integer32 (1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines how many frames will be received on the link
before the PS will send Acknowledge (RR frame).
It is used for Piggy Back Acknowledge (ack within the info frames)
and saves traffic on the line.
Default value: 1 ."
::= { pktSwchLapbAEntry 17 }
pktSwchLapbAckTimerA OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Ack Timer defines the maximum time in seconds that the device
will wait before sending RR acknowledgment on the received frames.
It is used for Piggy Back Acknowledge (ack within the info frames)
and saves traffic on the line.
Default value: 0 ."
::= { pktSwchLapbAEntry 18 }
-- PLP (Packet Layer Protocol: Scratch + Active}
pktSwchPlp OBJECT IDENTIFIER ::= { pktSwchx25 2 }
-- PLP Scratch table
pktSwchPlpSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchPlpSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Scratch Plp Table includes configurable objects provided by the PS
that are not included in RFC 1382."
::= { pktSwchPlp 1 }
pktSwchPlpSEntry OBJECT-TYPE
SYNTAX PktSwchPlpSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the RAD Scratch Plp Table."
INDEX { pktSwchPlpLinkNumberS }
::= { pktSwchPlpSTable 1 }
PktSwchPlpSEntry ::= SEQUENCE {
pktSwchPlpLinkNumberS
Integer32,
pktSwchPlpInCallOptionS
Integer32,
pktSwchPlpOutCallOptionS
Integer32,
pktSwchPlpCugSubscriptionS
INTEGER,
pktSwchPlpNUIS
Integer32,
pktSwchPlpCpyPktSize
Integer32,
pktSwchPlpCpyWinSize
Integer32
}
pktSwchPlpLinkNumberS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex of the X.25 interface."
::= { pktSwchPlpSEntry 1 }
pktSwchPlpInCallOptionS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The in call options for the link. The value is a sum of values (powers of two), where each
value in the sum represents an option. The values that may be included in the sum and
their meanings are:
0 No options
1 Fast select acceptance - included in RFC 1382
2 Reverse charge acceptance - included in RFC 1382
4 Subaddress in Call User Data field (CUD)
8 Protocol ID (PID) is not used.
16 Assume PVC down when link is synchronized
32 Delay Reset Response by 2 seconds."
::= { pktSwchPlpSEntry 2 }
pktSwchPlpOutCallOptionS OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The out call options for the link. The value is a sum of values
(powers of two), where each value in the sum represents an
option. The values that may be included in the sum and their
meanings are:
0 No options
1 Don't add calling and call addressin call accept packet
2 Network link, call request spread enabled
4 Add source link number to called address
8 Don't change calling address
XX - Any combination of the values specified above."
::= { pktSwchPlpSEntry 3 }
pktSwchPlpCugSubscriptionS OBJECT-TYPE
SYNTAX INTEGER {
cug(1), -- CUG with preferential
cugOa(2), -- CUG/OA with preferential
cugIa(3), -- CUG/IA with preferential
cugOaIa(4), -- CUG/OA/IA with preferential
noPref(5), -- CUG/OA/IA without preferential (transparent)
noCug(255) -- no CUG
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The CUG subscription for the link."
::= { pktSwchPlpSEntry 4 }
pktSwchPlpNUIS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the NUI group which this Plp is part of."
::= { pktSwchPlpSEntry 5 }
pktSwchPlpCpyPktSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"x25 packet size."
::= { pktSwchPlpSEntry 6 }
pktSwchPlpCpyWinSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"x25 window size."
::= { pktSwchPlpSEntry 7 }
-- PLP Active table
pktSwchPlpATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchPlpAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Active Plp Table includes objects provided by the PS
that are not included in RFC 1382. It also includes some packet
layer statistics, some of which are defined in RFC 1382, but are
not supported there, as the x25StatTable in RFC 1382 is not supported."
::= { pktSwchPlp 2 }
pktSwchPlpAEntry OBJECT-TYPE
SYNTAX PktSwchPlpAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the RAD Active Plp Table."
INDEX { pktSwchPlpLinkNumberA }
::= { pktSwchPlpATable 1 }
PktSwchPlpAEntry ::= SEQUENCE {
pktSwchPlpLinkNumberA
Integer32,
pktSwchPlpInCallOptionA
Integer32,
pktSwchPlpOutCallOptionA
Integer32,
pktSwchPlpCugSubscriptionA
INTEGER,
pktSwchPlpNUIA
Integer32,
pktSwchStatOutRestarts
Counter32
}
pktSwchPlpLinkNumberA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link number with which this entry is associated. This value corresponds to
pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is
X.25 and one entry for each link and DLCI if the pktSwchPhyInterfaceProtocol for the link is Frame
Relay and theDLCI is defined as using X.25."
::= { pktSwchPlpAEntry 1 }
pktSwchPlpInCallOptionA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current in call options for the link. The value is a sum of values (powers of two),
where each value in the sum represents an option. The values that can be included in
the sum and their meanings are:
0 No options
1 Fast select acceptance - included in RFC 1382
2 Reverse charge acceptance - included in RFC 1382
4 Subaddress in Call User Data field (CUD)
8 Protocol ID (PID) is not used.
16 Assume PVC down when link is synchronized
32 Delay Reset Response by 2 seconds."
::= { pktSwchPlpAEntry 2 }
pktSwchPlpOutCallOptionA OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The out call options for the link. The value is a sum of values
(powers of two), where each value in the sum represents an
option. The values that may be included in the sum and their
meanings are:
0 No options
1 Don't add calling and call addressin call accept packet
2 Network link, call request spread enabled
4 Add source link number to called address
8 Don't change calling address
XX - Any combination of the values specified above."
::= { pktSwchPlpAEntry 3 }
pktSwchPlpCugSubscriptionA OBJECT-TYPE
SYNTAX INTEGER {
cug(1), -- CUG with preferential
cugOa(2), -- CUG/OA with preferential
cugIa(3), -- CUG/IA with preferential
cugOaIa(4), -- CUG/OA/IA with preferential
noPref(5), -- CUG/OA/IA without preferential (transparent)
noCug(255) -- no CUG
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current CUG subscription for the link."
::= { pktSwchPlpAEntry 4 }
pktSwchPlpNUIA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the NUI group which this Plp is part of."
::= { pktSwchPlpAEntry 5 }
pktSwchStatOutRestarts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of remotely initiated (including
provider initiated) restarts experienced by
the PLE excluding the restart associated
with bringing up the PLE interface. This
only counts restarts received when the PLE
already has an established connection with
the remove PLE."
::= { pktSwchPlpAEntry 6 }
pktSwchPlaceHolderForFutureUse OBJECT IDENTIFIER ::= { pktSwchx25 3 }
-- CUG (Scratch + Active}
pktSwchCug OBJECT IDENTIFIER ::= { pktSwchx25 4 }
-- CUG Scratch table
pktSwchCugSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchCugSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Scratch Cug Table lists the Closed User Groups defined to each
X.25 link."
::= { pktSwchCug 1 }
pktSwchCugSEntry OBJECT-TYPE
SYNTAX PktSwchCugSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the Scratch RAD Cug Table."
INDEX { pktSwchCugLinkNumberS, pktSwchCugIndexS }
::= { pktSwchCugSTable 1 }
PktSwchCugSEntry ::= SEQUENCE {
pktSwchCugLinkNumberS
Integer32,
pktSwchCugIndexS
Integer32,
pktSwchCugNumberS
Integer32,
pktSwchCugStatus
INTEGER
}
pktSwchCugLinkNumberS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link number with which this entry is associated. This value
corresponds to pktSwchPhyInterfaceNumber. There is an entry for
each link for which the pktSwchPhyInterfaceProtocol is X.25 if the
link has CUG options and one entry for each link and DLCI if the
pktSwchPhyInterfaceProtocol for the link is Frame Relay and the DLCI
is defined as using X.25 if the link has CUG options."
::= { pktSwchCugSEntry 1 }
pktSwchCugIndexS OBJECT-TYPE
SYNTAX Integer32 -- how many CUGs??
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the CUG for a specific link. The lowest indexed CUG
is the preferential CUG."
::= { pktSwchCugSEntry 2 }
pktSwchCugNumberS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The CUG number for this entry."
::= { pktSwchCugSEntry 3 }
pktSwchCugStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this CUG table entry. The choices are those defined in the SNMPv2 Textual
Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with
the RowStatus textual convention SYNTAX."
::= { pktSwchCugSEntry 4 }
-- CUG Active table
pktSwchCugATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchCugAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Active Cug Table lists the active Closed User Groups defined
to each X.25 link."
::= { pktSwchCug 2 }
pktSwchCugAEntry OBJECT-TYPE
SYNTAX PktSwchCugAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the Active RAD Cug Table."
INDEX { pktSwchCugLinkNumberA, pktSwchCugIndexA }
::= { pktSwchCugATable 1 }
PktSwchCugAEntry ::= SEQUENCE {
pktSwchCugLinkNumberA
Integer32,
pktSwchCugIndexA
Integer32,
pktSwchCugNumberA
Integer32
}
pktSwchCugLinkNumberA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link number with which this entry is associated. This value corresponds to
pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is
X.25 if the link has CUG options and one entry for each link and DLCI if the
pktSwchPhyInterfaceProtocol for the link is Frame Relay and theDLCI is defined as using X.25
if the link has CUG options."
::= { pktSwchCugAEntry 1 }
pktSwchCugIndexA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the CUG for a specific link. The lowest indexed CUG is the preferential CUG."
::= { pktSwchCugAEntry 2 }
pktSwchCugNumberA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CUG number for this entry."
::= { pktSwchCugAEntry 3 }
-- X.25 Channel LCN Table
pktSwchLogCh OBJECT IDENTIFIER ::= { pktSwchx25 5 }
pktSwchLogChAssTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchLogChAssEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"These objects contain information about the
channel number configuration in an X.25 PLE.
These values are the configured values.
changes in these values after the interface
has started may not be reflected in the
operating PLE."
REFERENCE "See ISO 8208, Section 3.7"
::= {pktSwchLogCh 1 }
pktSwchLogChAssEntry OBJECT-TYPE
SYNTAX PktSwchLogChAssEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries of pktSwchLogChAssTable."
REFERENCE "This provides the information available
in 10733 logicalChannelAssignments."
INDEX { pktSwchLogChAssIndex }
::= { pktSwchLogChAssTable 1 }
PktSwchLogChAssEntry ::= SEQUENCE {
pktSwchLogChAssIndex
IfIndexType,
pktSwchLogChAssLIC
Integer32,
pktSwchLogChAssHIC
Integer32,
pktSwchLogChAssLTC
Integer32,
pktSwchLogChAssHTC
Integer32,
pktSwchLogChAssLOC
Integer32,
pktSwchLogChAssHOC
Integer32
}
pktSwchLogChAssIndex OBJECT-TYPE
SYNTAX IfIndexType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex value for the X.25 Interface."
::= { pktSwchLogChAssEntry 1 }
pktSwchLogChAssLIC OBJECT-TYPE
SYNTAX Integer32 (0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lowest Incoming channel."
::= { pktSwchLogChAssEntry 2 }
pktSwchLogChAssHIC OBJECT-TYPE
SYNTAX Integer32 (0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Highest Incoming channel. A value of zero
indicates no channels in this range."
::= { pktSwchLogChAssEntry 3 }
pktSwchLogChAssLTC OBJECT-TYPE
SYNTAX Integer32 (0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lowest Two-way channel."
::= { pktSwchLogChAssEntry 4 }
pktSwchLogChAssHTC OBJECT-TYPE
SYNTAX Integer32 (0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Highest Two-way channel. A value of zero
indicates no channels in this range."
::= { pktSwchLogChAssEntry 5 }
pktSwchLogChAssLOC OBJECT-TYPE
SYNTAX Integer32 (0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lowest outgoing channel."
::= { pktSwchLogChAssEntry 6 }
pktSwchLogChAssHOC OBJECT-TYPE
SYNTAX Integer32 (0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Highest outgoing channel. A value of zero
indicates no channels in this range."
::= { pktSwchLogChAssEntry 7 }
pktSwchLogChPartnerTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchLogChPartnerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"These objects contain information about the
partner channel number configuration in an X.25 PLE.
These values are the configured values.
changes in these values after the interfaces
has started may not be reflected in the
operating PLE."
REFERENCE "See ISO 8208, Section 3.7"
::= {pktSwchLogCh 2 }
pktSwchLogChPartnerEntry OBJECT-TYPE
SYNTAX PktSwchLogChPartnerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries of pktSwchLogChPartnerTable."
REFERENCE "This provides the information available
in 10733 logicalChannelPartners."
INDEX { pktSwchLogChPartnerIfIndex, pktSwchLogChPartnerLcIndex }
::= { pktSwchLogChPartnerTable 1 }
PktSwchLogChPartnerEntry ::= SEQUENCE {
pktSwchLogChPartnerIfIndex
IfIndexType,
pktSwchLogChPartnerLcIndex
Integer32,
pktSwchLogChPartnerProtocol
INTEGER,
pktSwchLogChPartnerOpIfIndex
IfIndexType,
pktSwchLogChPartnerOpLcIndex
Integer32
}
pktSwchLogChPartnerIfIndex OBJECT-TYPE
SYNTAX IfIndexType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex value for the Lapb Interface."
::= { pktSwchLogChPartnerEntry 1 }
pktSwchLogChPartnerLcIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Index value for the LCN."
::= { pktSwchLogChPartnerEntry 2 }
pktSwchLogChPartnerProtocol OBJECT-TYPE
SYNTAX INTEGER {
other(1),
x25(2),
hdlc(3),
sdlc(4),
async(5),
mpe(6),
ip(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The protocol of the partner."
::= { pktSwchLogChPartnerEntry 3 }
pktSwchLogChPartnerOpIfIndex OBJECT-TYPE
SYNTAX IfIndexType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex value for the partner Lapb Interface."
::= { pktSwchLogChPartnerEntry 4 }
pktSwchLogChPartnerOpLcIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Index value for the partner LCN."
::= { pktSwchLogChPartnerEntry 5 }
-- The PS HDLC Group contains HDLC Scratch and Active Tables, which contain configuration for
-- HDLC links
pktSwchHdlc OBJECT IDENTIFIER ::= { radPS 5 }
pktSwchHdlcSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchHdlcSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Scratch Hdlc Table contains configuration information for HDLC links"
::= { pktSwchHdlc 1 }
pktSwchHdlcSEntry OBJECT-TYPE
SYNTAX PktSwchHdlcSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the RAD Hdlc Table."
INDEX { pktSwchHdlcLinkNumberS }
::= { pktSwchHdlcSTable 1 }
PktSwchHdlcSEntry ::= SEQUENCE {
pktSwchHdlcLinkNumberS
Integer32,
pktSwchHdlcDestAddrS
DisplayString,
pktSwchHdlcDestSubAddrS
Integer32,
pktSwchHdlcRedialTimeoutS
Integer32,
pktSwchHdlcRedialRetriesS
Integer32,
pktSwchHdlcInactivityS
Integer32,
pktSwchHdlcX25FacilitiesS
Integer32,
pktSwchHdlcLocalSubaddr1S
Integer32,
pktSwchHdlcLocalSubaddr2S
Integer32,
pktSwchHdlcDestDlciS
Integer32,
pktSwchHdlcDestPortS
Integer32,
pktSwchHdlcProtocolS
INTEGER,
pktSwchHdlcFlowContOptionsS
Integer32,
pktSwchHdlcBufferFlowControlS
Integer32,
pktSwchHdlcInternalClockS
INTEGER,
pktSwchHdlcNrzModeS
Integer32
}
pktSwchHdlcLinkNumberS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link number with which this entry is associated. This value
corresponds to pktSwchPhyInterfaceNumber. There is an entry for
each link for which the pktSwchPhyInterfaceProtocol is HDLC."
::= { pktSwchHdlcSEntry 1 }
pktSwchHdlcDestAddrS OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination address. It defines the X.25 address on the remote
device."
::= { pktSwchHdlcSEntry 2 }
pktSwchHdlcDestSubAddrS OBJECT-TYPE
SYNTAX Integer32 (0..99)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination subaddress. It defines the synchronous link subaddress
on the remote device."
::= { pktSwchHdlcSEntry 3 }
pktSwchHdlcRedialTimeoutS OBJECT-TYPE
SYNTAX Integer32 (0..255) -- seconds??
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time interval in seconds between two consecutive connect
operations retries."
::= { pktSwchHdlcSEntry 4 }
pktSwchHdlcRedialRetriesS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This defines how many times the call operation is repeated if the
call request has failed."
::= { pktSwchHdlcSEntry 5 }
pktSwchHdlcInactivityS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The amount of time in minutes of inactivity that will cause the
session to disconnect."
::= { pktSwchHdlcSEntry 6 }
pktSwchHdlcX25FacilitiesS OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This specifies the X.25 facilities. The value is a sum of values
(powers of two), where each value in the sum represents an option.
The values that may be included in the sum and their meanings are:
0 No options
1 Packet size negotiation
2 Window size negotiation
4 Reverse charge."
::= { pktSwchHdlcSEntry 7 }
pktSwchHdlcLocalSubaddr1S OBJECT-TYPE
SYNTAX Integer32 (0..99)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The first local subaddress."
::= { pktSwchHdlcSEntry 8 }
pktSwchHdlcLocalSubaddr2S OBJECT-TYPE
SYNTAX Integer32 (0..99)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The secondary local subaddress."
::= { pktSwchHdlcSEntry 9 }
pktSwchHdlcDestDlciS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The local DLCI which is used for HDLC encapsulation over Frame Relay.
Range: 16...991"
::= { pktSwchHdlcSEntry 10 }
pktSwchHdlcDestPortS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The local port that is used for HDLC encapsulation over Frame Relay.
Range: 1...12"
::= { pktSwchHdlcSEntry 11 }
pktSwchHdlcProtocolS OBJECT-TYPE
SYNTAX INTEGER {
hdlcOverX25(1), -- HDLC encapsulated over X.25
hdlcOverFrRel(2), -- HDLC encapsulated over Frame Relay
hdlcOverMpe(3), -- HDLC encapsulated over MPE
hdlcReg(4), -- HDLC regular protocol for inner routing
hdlcOverIp(5) -- HDLC encapsulated over IP
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The HDLC protocol type."
::= { pktSwchHdlcSEntry 12 }
pktSwchHdlcFlowContOptionsS OBJECT-TYPE
SYNTAX Integer32 (0..3)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This specifies the type of flow control of the HDLC link. The value
is a sum of values (powers of two), where each value in the sum
represents an option. The values that may be included in the sum and
their meanings are:
0 No flow control
1 CTS flow control
2 Clock flow control."
::= { pktSwchHdlcSEntry 13 }
pktSwchHdlcBufferFlowControlS OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of buffers that will be allocated for the HDLC link. Default value is 10"
::= { pktSwchHdlcSEntry 14 }
pktSwchHdlcInternalClockS OBJECT-TYPE
SYNTAX INTEGER {
r2400bps (1),
r4800bps (2),
r9600bps (3),
r14400bps(4),
r19200bps(5),
r38400bps(6),
r48Kbps (7),
r56Kbps (8),
r64Kbps (9),
r128Kbps (10),
r256Kbps (11),
r384Kbps (12),
r504Kbps (13),
r768Kbps (14),
r1008Kbps(15),
r1466Kbps(16),
r2016Kbps(17),
external(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The baud rate of the internal clock."
::= { pktSwchHdlcSEntry 15 }
pktSwchHdlcNrzModeS OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The data encoding format.
The value is a sum of values (powers of two), where each
value in the sum represents an option.
The values that may be included in the sum and their
meanings are:
0 NRZ
1 NRZI
2 Transmit Idles between frames and control the RTS pin
4 Normal Operation (DCD, CTS lines under automatic control)
XX Any combination of the values specified above."
::= { pktSwchHdlcSEntry 16 }
pktSwchHdlcATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchHdlcAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Active Hdlc Table contains active configuration information for HDLC links"
::= { pktSwchHdlc 2 }
pktSwchHdlcAEntry OBJECT-TYPE
SYNTAX PktSwchHdlcAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the RAD Hdlc Table."
INDEX { pktSwchHdlcLinkNumberA }
::= { pktSwchHdlcATable 1 }
PktSwchHdlcAEntry ::= SEQUENCE {
pktSwchHdlcLinkNumberA
Integer32,
pktSwchHdlcDestAddrA
DisplayString,
pktSwchHdlcDestSubAddrA
Integer32,
pktSwchHdlcRedialTimeoutA
Integer32,
pktSwchHdlcRedialRetriesA
Integer32,
pktSwchHdlcInactivityA
Integer32,
pktSwchHdlcX25FacilitiesA
Integer32,
pktSwchHdlcLocalSubaddr1A
Integer32,
pktSwchHdlcLocalSubaddr2A
Integer32,
pktSwchHdlcDestDlciA
Integer32,
pktSwchHdlcDestPortA
Integer32,
pktSwchHdlcProtocolA
INTEGER,
pktSwchHdlcFlowContOptionsA
Integer32,
pktSwchHdlcBufferFlowControlA
Integer32,
pktSwchHdlcInternalClockA
INTEGER,
pktSwchHdlcNrzModeA
Integer32,
pktSwchHdlcConnStatus
INTEGER,
pktSwchHdlcSpecialStatus
INTEGER,
pktSwchHdlcCtsStatus
INTEGER,
pktSwchHdlcRunningX25Lcn
DisplayString,
pktSwchHdlcRunningDlci
DisplayString,
pktSwchHdlcMaxBuffToNet
Integer32,
pktSwchHdlcBuffToNet
Integer32
}
pktSwchHdlcLinkNumberA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link number with which this entry is associated. This value corresponds to
pktSwchPhyInterfaceNumber. There is an entry for each link for which the pktSwchPhyInterfaceProtocol is
HDLC."
::= { pktSwchHdlcAEntry 1 }
pktSwchHdlcDestAddrA OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The destination address. It defines the X.25 address on the remote device."
::= { pktSwchHdlcAEntry 2 }
pktSwchHdlcDestSubAddrA OBJECT-TYPE
SYNTAX Integer32 (0..99)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The destination subaddress. It defines the synchronous link subaddress on the remote
device."
::= { pktSwchHdlcAEntry 3 }
pktSwchHdlcRedialTimeoutA OBJECT-TYPE
SYNTAX Integer32 (0..255) -- seconds??
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time interval in seconds between two consecutive connect operations retries."
::= { pktSwchHdlcAEntry 4 }
pktSwchHdlcRedialRetriesA OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This defines how many times the call operation is repeated if the call request has failed."
::= { pktSwchHdlcAEntry 5 }
pktSwchHdlcInactivityA OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of time in minutes of inactivity that will cause the
session to disconnect."
::= { pktSwchHdlcAEntry 6 }
pktSwchHdlcX25FacilitiesA OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This specifies the X.25 facilities. The value is a sum of values (powers of two), where each
value in the sum represents an option. The values that may be included in the sum and
their meanings are:
0 No options
1 Packet size negotiation
2 Window size negotiation
4 Reverse charge."
::= { pktSwchHdlcAEntry 7 }
pktSwchHdlcLocalSubaddr1A OBJECT-TYPE
SYNTAX Integer32 (0..99)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The first local subaddress."
::= { pktSwchHdlcAEntry 8 }
pktSwchHdlcLocalSubaddr2A OBJECT-TYPE
SYNTAX Integer32 (0..99)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The secondary local subaddress."
::= { pktSwchHdlcAEntry 9 }
pktSwchHdlcDestDlciA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The local DLCI which is used for HDLC encapsulation over Frame Relay."
::= { pktSwchHdlcAEntry 10 }
pktSwchHdlcDestPortA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The local port that is used for HDCL encapsulation over Frame Relay."
::= { pktSwchHdlcAEntry 11 }
pktSwchHdlcProtocolA OBJECT-TYPE
SYNTAX INTEGER {
hdlcOverX25(1), -- HDLC encapsulated over X.25
hdlcOverFrRel(2), -- HDLC encapsulated over Frame Relay
hdlcOverMpe(3), -- HDLC encapsulated over MPE
hdlcReg(4), -- HDLC regular protocol for inner routing
hdlcOverIp(5) -- It is actually IP over HDLC
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The HDLC protocol type."
::= { pktSwchHdlcAEntry 12 }
pktSwchHdlcFlowContOptionsA OBJECT-TYPE
SYNTAX Integer32 (0..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This specifies the type of flow control of the HDLC link. The value is a sum of values
(powers of two), where each value in the sum represents an option. The values that may
be included in the sum and their meanings are:
0 No flow control
1 CTS flow control
2 Clock flow control."
::= { pktSwchHdlcAEntry 13 }
pktSwchHdlcBufferFlowControlA OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of buffers that will be allocated for the HDLC link."
::= { pktSwchHdlcAEntry 14 }
pktSwchHdlcInternalClockA OBJECT-TYPE
SYNTAX INTEGER {
r2400bps (1),
r4800bps (2),
r9600bps (3),
r14400bps(4),
r19200bps(5),
r38400bps(6),
r48Kbps (7),
r56Kbps (8),
r64Kbps (9),
r128Kbps (10),
r256Kbps (11),
r384Kbps (12),
r504Kbps (13),
r768Kbps (14),
r1008Kbps(15),
r1466Kbps(16),
r2016Kbps(17),
external(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The baud rate of the internal clock."
::= { pktSwchHdlcAEntry 15 }
pktSwchHdlcNrzModeA OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The data encoding format.
The value is a sum of values (powers of two), where each
value in the sum represents an option.
The values that may be included in the sum and their
meanings are:
0 NRZ
1 NRZI
2 Transmit Idles between frames and control the RTS pin
4 Normal Operation (DCD, CTS lines under automatic control)
XX Any combination of the values specified above."
::= { pktSwchHdlcAEntry 16 }
pktSwchHdlcConnStatus OBJECT-TYPE
SYNTAX INTEGER {
disconnect(1),
connect(2),
pvc(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the Hdlc session."
::= { pktSwchHdlcAEntry 17 }
pktSwchHdlcSpecialStatus OBJECT-TYPE
SYNTAX INTEGER {
busy(1),
overflow(2),
noStatus(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the Hdlc link."
::= { pktSwchHdlcAEntry 18 }
pktSwchHdlcCtsStatus OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CTS status."
::= { pktSwchHdlcAEntry 19 }
pktSwchHdlcRunningX25Lcn OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The format of the string is ifIndex:LCN "
::= { pktSwchHdlcAEntry 20 }
pktSwchHdlcRunningDlci OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The format of the string is ifIndex:DLCI"
::= { pktSwchHdlcAEntry 21 }
pktSwchHdlcMaxBuffToNet OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of buffers above which Flow Control is enabled"
::= { pktSwchHdlcAEntry 22 }
pktSwchHdlcBuffToNet OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of buffers waiting for transmission."
::= { pktSwchHdlcAEntry 23 }
pktSwchStmTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchStmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The STM table contains information for STM links"
::= { radPS 7 }
pktSwchStmEntry OBJECT-TYPE
SYNTAX PktSwchStmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the RAD STM Table."
INDEX { pktSwchStmLinkNumber }
::= { pktSwchStmTable 1 }
PktSwchStmEntry ::= SEQUENCE {
pktSwchStmLinkNumber
Integer32,
pktSwchStmInternalClockS
INTEGER,
pktSwchStmInternalClockA
INTEGER,
pktSwchStmConn
INTEGER,
pktSwchStmSyncLoss
Counter32
}
pktSwchStmLinkNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link number with which this entry is associated. This value
corresponds to pktSwchPhyInterfaceNumber. There is an entry for
each link whose pktSwchPhyInterfaceProtocol is STM 4, 8, 16, or 24."
::= { pktSwchStmEntry 1 }
pktSwchStmInternalClockS OBJECT-TYPE
SYNTAX INTEGER {
r2400bps (1),
r4800bps (2),
r9600bps (3),
r14400bps(4),
r19200bps(5),
r38400bps(6),
r48Kbps (7),
r56Kbps (8),
r64Kbps (9),
r128Kbps (10),
r256Kbps (11),
r384Kbps (12),
r504Kbps (13),
r768Kbps (14),
r1008Kbps(15),
r1466Kbps(16),
r2016Kbps(17),
external(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The baud rate of the internal clock."
::= { pktSwchStmEntry 2 }
pktSwchStmInternalClockA OBJECT-TYPE
SYNTAX INTEGER {
r2400bps (1),
r4800bps (2),
r9600bps (3),
r14400bps(4),
r19200bps(5),
r38400bps(6),
r48Kbps (7),
r56Kbps (8),
r64Kbps (9),
r128Kbps (10),
r256Kbps (11),
r384Kbps (12),
r504Kbps (13),
r768Kbps (14),
r1008Kbps(15),
r1466Kbps(16),
r2016Kbps(17),
external(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current baud rate of the internal clock."
::= { pktSwchStmEntry 3 }
pktSwchStmConn OBJECT-TYPE
SYNTAX INTEGER {
disconnect(1),
connect(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The connectivity status of the STM interface."
::= { pktSwchStmEntry 4 }
pktSwchStmSyncLoss OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter for sync loss."
::= { pktSwchStmEntry 5 }
-- The PS Frame Relay Group
pktSwchFr OBJECT IDENTIFIER ::= { radPS 8 }
pktSwchFrTotFunnels OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of Funnels on the PS."
::= { pktSwchFr 1 }
pktSwchFrSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchFrSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay Scratch Table includes the scratch values of
configurable objects provided by the PS that are not included
in RFC 1315."
::= { pktSwchFr 2 }
pktSwchFrSEntry OBJECT-TYPE
SYNTAX PktSwchFrSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the RAD PS Frame Relay
Scratch Table."
INDEX { pktSwchFrIfIndexS }
::= { pktSwchFrSTable 1 }
PktSwchFrSEntry ::= SEQUENCE {
pktSwchFrIfIndexS
Integer32,
pktSwchFrMaintProtS
Integer32,
pktSwchFrMaintModeS
INTEGER,
pktSwchFrRxPoolRedLineS
Integer32,
pktSwchFrRxPoolOkS
Integer32,
pktSwchFrTxPoolRedLineS
Integer32,
pktSwchFrTxPoolOkS
Integer32,
pktSwchFrTxCeilingS
Integer32,
pktSwchFrInternalClockS
INTEGER,
pktSwchFrNrzModeS
INTEGER,
pktSwchFrDlciHeaderModeS
INTEGER,
pktSwchFrDcdLinkFailureS
INTEGER,
pktSwchFrTxIdlesS
INTEGER,
pktSwchFrOperationModeS
INTEGER,
pktSwchFrPhysInterfOptionsS
INTEGER
}
pktSwchFrIfIndexS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the ifIndex of the frame relay port."
::= { pktSwchFrSEntry 1 }
pktSwchFrMaintProtS OBJECT-TYPE
SYNTAX Integer32 (0..12)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This defines what maintenance protocol is running over this port.
0 - No maintenance protocol.
1 - ANSI PVC maintenance protocol running on DLCI number 0.
2 - LMI maintenance protocol running on DLCI number 1023.
4 - ITU Q.933 ANNEX A maintenance protocol running on DLCI number 0.
8 - Consolidate Link Layer Management CLLM running on DLCI number 1023.
8 cannot be a choice by itself, it can only be as part of the
combination 9, 10, 12.
XXX - The combination of 9, 10, 12."
::= { pktSwchFrSEntry 2 }
pktSwchFrMaintModeS OBJECT-TYPE
SYNTAX INTEGER {
user(1),
network(2),
both(3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This defines the mode of maintenance protocol running over this port."
::= { pktSwchFrSEntry 3 }
pktSwchFrRxPoolRedLineS OBJECT-TYPE
SYNTAX Integer32 (0..39)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the number of empty receive buffers at the port reaches this
figure (of frames),the port receiver is congested. This field
value should be less than the Rx pool OK field."
::= { pktSwchFrSEntry 4 }
pktSwchFrRxPoolOkS OBJECT-TYPE
SYNTAX Integer32 (1..40)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear the receive congestion condition when the number of empty
receive buffers at the port reaches this figure. This value
(of frames) should be greater than the Rx pool red line."
::= { pktSwchFrSEntry 5 }
pktSwchFrTxPoolRedLineS OBJECT-TYPE
SYNTAX Integer32 (1..500)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the number of frames awaiting transmission reaches this figure,
the port transmitter is congested. This field value should be
greater than the Tx pool OK field."
::= { pktSwchFrSEntry 6 }
pktSwchFrTxPoolOkS OBJECT-TYPE
SYNTAX Integer32 (0..499)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear the transmit congestion condition when the number of frames
awaiting transmission at the port reaches this figure. This value
(of frames) should be less than the Tx pool red line."
::= { pktSwchFrSEntry 7 }
pktSwchFrTxCeilingS OBJECT-TYPE
SYNTAX Integer32 (1..500)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum allowable transmit pool for this port."
::= { pktSwchFrSEntry 8 }
pktSwchFrInternalClockS OBJECT-TYPE
SYNTAX INTEGER {
r2400bps (1),
r4800bps (2),
r9600bps (3),
r14400bps(4),
r19200bps(5),
r38400bps(6),
r48Kbps (7),
r56Kbps (8),
r64Kbps (9),
r128Kbps (10),
r256Kbps (11),
r384Kbps (12),
r504Kbps (13),
r768Kbps (14),
r1008Kbps(15),
r1466Kbps(16),
r2016Kbps(17),
external (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The baud rate of the internal clock."
::= { pktSwchFrSEntry 9 }
pktSwchFrNrzModeS OBJECT-TYPE
SYNTAX INTEGER {
nrz(1),
nrzi(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The data encoding format."
::= { pktSwchFrSEntry 10 }
pktSwchFrDlciHeaderModeS OBJECT-TYPE
SYNTAX INTEGER {
two-octets(1),
three-octets(2),
four-octets(3),
four-octets-nomanag(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Dlci Header length for this FR port. Option 4 means that there
will be no management Dlci in the range of 1024 to 8388607.
The management Dlci will be in the range of 0-15 or 991-1023.
Default value: 1."
::= { pktSwchFrSEntry 11 }
pktSwchFrDcdLinkFailureS OBJECT-TYPE
SYNTAX INTEGER {
no-Detect(2),
linkFailure-Detect(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Link Failure Detection by DCD.
If Link Failure detection by DCD is on - (3), when the DCD is
down, the FR SW will detect it and change the FR link status
from UP to DOWN. A trap of LINK DOWN will be sent to the NMS.
Default: (2)."
::= { pktSwchFrSEntry 12 }
pktSwchFrTxIdlesS OBJECT-TYPE
SYNTAX INTEGER {
no(2),
yes(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter shows whether the PS will Transmit Idles between
frames and control the RTS pin.
Default: no(2)."
::= { pktSwchFrSEntry 13 }
pktSwchFrOperationModeS OBJECT-TYPE
SYNTAX INTEGER {
swControl(2),
hwControl(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When H/W Control is configured, the SCC H/W will detect the change in the
DCD or CTS signals and Start or Stop transmission automatically.
When S/W Control is configured the S/W will decide when to start or stop
the transmission.
Default: swControl(2)."
::= { pktSwchFrSEntry 14 }
pktSwchFrPhysInterfOptionsS OBJECT-TYPE
SYNTAX INTEGER {
noOption(2),
dds4800bps(3),
dds9600bps(4),
dds19200bps(5),
dds56000bos(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the physical interface.
Note that the DDS physical interface H/W does not exist in the FPS-8.
It is relevant for other PS devices only.
For FPS-8 only the default (noOption) should be used.
Default: (2)."
::= { pktSwchFrSEntry 15 }
pktSwchFrATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchFrAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay Active Table includes statistics and the active values of configurable
objects provided by the PS that are not included in RFC 1315."
::= { pktSwchFr 3 }
pktSwchFrAEntry OBJECT-TYPE
SYNTAX PktSwchFrAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the RAD PS Frame Relay Active Table."
INDEX { pktSwchFrIfIndexA }
::= { pktSwchFrATable 1 }
PktSwchFrAEntry ::= SEQUENCE {
pktSwchFrIfIndexA
Integer32,
pktSwchFrMaintProtA
Integer32,
pktSwchFrMaintModeA
INTEGER,
pktSwchFrRxPoolRedLineA
Integer32,
pktSwchFrRxPoolOkA
Integer32,
pktSwchFrTxPoolRedLineA
Integer32,
pktSwchFrTxPoolOkA
Integer32,
pktSwchFrTxCeilingA
Integer32,
pktSwchFrInternalClockA
INTEGER,
pktSwchFrNrzModeA
INTEGER,
pktSwchFrDlcmiPollingInterval
Integer32,
pktSwchFrDlcmiFullEnquiryInterval
Integer32,
pktSwchFrDlcmiErrorThreshold
Integer32,
pktSwchFrDlcmiMonitoredEvents
Integer32,
pktSwchFrDlciHeaderModeA
INTEGER,
pktSwchFrDcdLinkFailureA
INTEGER,
pktSwchFrTxIdlesA
INTEGER,
pktSwchFrOperationModeA
INTEGER,
pktSwchFrPhysInterfOptionsA
INTEGER
}
pktSwchFrIfIndexA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the ifIndex of the frame relay port."
::= { pktSwchFrAEntry 1 }
pktSwchFrMaintProtA OBJECT-TYPE
SYNTAX Integer32 (0..12)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This defines what maintenance protocol is running over this port.
0 - No maintenance protocol.
1 - ANSI PVC maintenance protocol running on DLCI number 0.
2 - LMI maintenance protocol running on DLCI number 1023.
4 - ITU Q.933 ANNEX A maintenance protocol running on DLCI number 0.
8 - Consolidate Link Layer Management CLLM running on DLCI number 1023.
8 cannot be a choice by itself, it can only be as part of the
combination 9, 10, 12.
XXX - The combination of 9, 10, 12."
::= { pktSwchFrAEntry 2 }
pktSwchFrMaintModeA OBJECT-TYPE
SYNTAX INTEGER {
user(1),
network(2),
both(3)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This defines the mode of maintenance protocol running over this port."
::= { pktSwchFrAEntry 3 }
pktSwchFrRxPoolRedLineA OBJECT-TYPE
SYNTAX Integer32 (0..39)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When the number of empty receive buffers at the port reaches this figure (of frames),
the port receiver is congested. This field value should be less than the Rx pool OK field."
::= { pktSwchFrAEntry 4 }
pktSwchFrRxPoolOkA OBJECT-TYPE
SYNTAX Integer32 (1..40)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clear the receive congestion condition when the number of empty receive buffers at the port
reaches this figure. This value (of frames) should be greater than the Rx pool red line."
::= { pktSwchFrAEntry 5 }
pktSwchFrTxPoolRedLineA OBJECT-TYPE
SYNTAX Integer32 (1..500)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When the number of frames awaiting transmission reaches this figure,
the port transmitter is congested. This field value should be greater than the Tx pool OK field."
::= { pktSwchFrAEntry 6 }
pktSwchFrTxPoolOkA OBJECT-TYPE
SYNTAX Integer32 (0..499)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clear the transmit congestion condition when the number of frames awaiting transmission
at the port reaches this figure. This value (of frames) should be less than the Tx pool red line."
::= { pktSwchFrAEntry 7 }
pktSwchFrTxCeilingA OBJECT-TYPE
SYNTAX Integer32 (0..500)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum allowable transmit pool for this port."
::= { pktSwchFrAEntry 8 }
pktSwchFrInternalClockA OBJECT-TYPE
SYNTAX INTEGER {
r2400bps (1),
r4800bps (2),
r9600bps (3),
r14400bps(4),
r19200bps(5),
r38400bps(6),
r48Kbps (7),
r56Kbps (8),
r64Kbps (9),
r128Kbps (10),
r256Kbps (11),
r384Kbps (12),
r504Kbps (13),
r768Kbps (14),
r1008Kbps(15),
r1466Kbps(16),
r2016Kbps(17),
external (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The baud rate of the internal clock."
::= { pktSwchFrAEntry 9 }
pktSwchFrNrzModeA OBJECT-TYPE
SYNTAX INTEGER {
nrz(1),
nrzi(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The data encoding format."
::= { pktSwchFrAEntry 10 }
pktSwchFrDlcmiPollingInterval OBJECT-TYPE
SYNTAX Integer32 (5..30)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the number of seconds between succes-
sive status enquiry messages."
REFERENCE
"Draft American National Standard T1.617-1991,
Section D.7 Timer T391."
DEFVAL { 10 }
::= { pktSwchFrAEntry 11 }
pktSwchFrDlcmiFullEnquiryInterval OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of status enquiry intervals that pass
before issuance of a full status enquiry mes-
sage."
REFERENCE
"Draft American National Standard T1.617-1991,
Section D.7 Counter32 N391."
DEFVAL { 6 }
::= { pktSwchFrAEntry 12 }
pktSwchFrDlcmiErrorThreshold OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the maximum number of unanswered
Status Enquiries the equipment shall accept be-
fore declaring the interface down."
REFERENCE
"Draft American National Standard T1.617-1991,
Section D.5.1 Counter32 N392."
DEFVAL { 3 }
::= { pktSwchFrAEntry 13 }
pktSwchFrDlcmiMonitoredEvents OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the number of status polling intervals
over which the error threshold is counted. For
example, if within 'MonitoredEvents' number of
events the station receives 'ErrorThreshold'
number of errors, the interface is marked as
down."
REFERENCE
"Draft American National Standard T1.617-1991,
Section D.5.2 Counter32 N393."
DEFVAL { 4 }
::= { pktSwchFrAEntry 14 }
pktSwchFrDlciHeaderModeA OBJECT-TYPE
SYNTAX INTEGER {
two-octets(1),
three-octets(2),
four-octets(3),
four-octets-nomanag(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Dlci Header length for this FR port. Option 4 means that there
will be no management Dlci in the range of 1024 to 8388607.
The management Dlci will be in the range of 0-15 or 991-1023.
Default value: 1."
::= { pktSwchFrAEntry 15 }
pktSwchFrDcdLinkFailureA OBJECT-TYPE
SYNTAX INTEGER {
no-Detect(2),
linkFailure-Detect(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link Failure Detection by DCD.
If Link Failure detection by DCD is on - (3), when the DCD is
down, the FR SW will detect it and change the FR link status
from UP to DOWN. A trap of LINK DOWN will be sent to the NMS.
Default: (2)."
::= { pktSwchFrAEntry 16 }
pktSwchFrTxIdlesA OBJECT-TYPE
SYNTAX INTEGER {
no(2),
yes(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter shows whether the PS will Transmit Idles between
frames and control the RTS pin.
Default: no(2)."
::= { pktSwchFrAEntry 17 }
pktSwchFrOperationModeA OBJECT-TYPE
SYNTAX INTEGER {
swControl(2),
hwControl(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When H/W Control is configured, the SCC H/W will detect the change in the
DCD or CTS signals and Start or Stop transmission automatically.
When S/W Control is configured the S/W will decide when to start or stop
the transmission.
Default: swControl(2)."
::= { pktSwchFrAEntry 18 }
pktSwchFrPhysInterfOptionsA OBJECT-TYPE
SYNTAX INTEGER {
noOption(2),
dds4800bps(3),
dds9600bps(4),
dds19200bps(5),
dds56000bos(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the physical interface.
Note that the DDS physical interface H/W does not exist in the FPS-8.
It is relevant for other PS devices only.
For FPS-8 only the default (noOption) should be used.
Default: (2)."
::= { pktSwchFrAEntry 19 }
pktSwchFrIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchFrIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay Active Port Table includes statistics and configurable objects
provided by the PS that are not included in RFC 1315."
::= { pktSwchFr 4 }
pktSwchFrIfEntry OBJECT-TYPE
SYNTAX PktSwchFrIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the RAD PS Frame Relay Port Active Table."
INDEX { ifIndex }
::= { pktSwchFrIfTable 1 }
PktSwchFrIfEntry ::= SEQUENCE {
pktSwchFrIfTxBytes
Counter32,
pktSwchFrIfRxBytes
Counter32,
pktSwchFrIfTxCongDiscards
Counter32,
pktSwchFrIfDeTxFrames
Counter32,
pktSwchFrIfDeRxFrames
Counter32,
pktSwchFrIfFecnTxFrames
Counter32,
pktSwchFrIfFecnRxFrames
Counter32,
pktSwchFrIfBecnTxFrames
Counter32,
pktSwchFrIfBecnRxFrames
Counter32,
pktSwchFrIfCommRateViolTxFrames
Counter32,
pktSwchFrIfCommRateViolRxFrames
Counter32,
pktSwchFrIfExcessRateViolTxFrames
Counter32,
pktSwchFrIfExcessRateViolRxFrames
Counter32,
pktSwchFrIfBuffersInTxPool
Integer32,
pktSwchFrIfFreeBuffersInRxPool
Integer32,
pktSwchFrIfLmiTxFrames
Counter32,
pktSwchFrIfLmiRxFrames
Counter32,
pktSwchFrIfAnsiTxFrames
Counter32,
pktSwchFrIfAnsiRxFrames
Counter32,
pktSwchFrIfCllmTxFrames
Counter32,
pktSwchFrIfCllmRxFrames
Counter32,
pktSwchFrIfTxCongestions
Counter32,
pktSwchFrIfRxCongestions
Counter32,
pktSwchFrIfTotDlciNumber
Integer32
}
pktSwchFrIfTxBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Tx bytes."
::= { pktSwchFrIfEntry 1 }
pktSwchFrIfRxBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Rx bytes."
::= { pktSwchFrIfEntry 2 }
pktSwchFrIfTxCongDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames discarded because of Tx congestion."
::= { pktSwchFrIfEntry 3 }
pktSwchFrIfDeTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of DE Tx frames."
::= { pktSwchFrIfEntry 4 }
pktSwchFrIfDeRxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of DE Rx frames."
::= { pktSwchFrIfEntry 5 }
pktSwchFrIfFecnTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of FECN Tx frames."
::= { pktSwchFrIfEntry 6 }
pktSwchFrIfFecnRxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of FECN Tx frames."
::= { pktSwchFrIfEntry 7 }
pktSwchFrIfBecnTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of BECN Tx frames."
::= { pktSwchFrIfEntry 8 }
pktSwchFrIfBecnRxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of BECN Tx frames."
::= { pktSwchFrIfEntry 9 }
pktSwchFrIfCommRateViolTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Tx committed rate violations in number of frames."
::= { pktSwchFrIfEntry 10 }
pktSwchFrIfCommRateViolRxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Rx committed rate violations in number of frames."
::= { pktSwchFrIfEntry 11 }
pktSwchFrIfExcessRateViolTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Tx excess rate violations in number of frames."
::= { pktSwchFrIfEntry 12 }
pktSwchFrIfExcessRateViolRxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Rx excess rate violations in number of frames."
::= { pktSwchFrIfEntry 13 }
pktSwchFrIfBuffersInTxPool OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of buffers waiting for transmission."
::= { pktSwchFrIfEntry 14 }
pktSwchFrIfFreeBuffersInRxPool OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of free buffers in the Rx pool."
::= { pktSwchFrIfEntry 15 }
pktSwchFrIfLmiTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of LMI Tx Frames."
::= { pktSwchFrIfEntry 16 }
pktSwchFrIfLmiRxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of LMI Rx Frames."
::= { pktSwchFrIfEntry 17 }
pktSwchFrIfAnsiTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ANSI Tx Frames."
::= { pktSwchFrIfEntry 18 }
pktSwchFrIfAnsiRxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ANSI Rx Frames."
::= { pktSwchFrIfEntry 19 }
pktSwchFrIfCllmTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of CLLM Tx Frames."
::= { pktSwchFrIfEntry 20 }
pktSwchFrIfCllmRxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of CLLM Rx Frames."
::= { pktSwchFrIfEntry 21 }
pktSwchFrIfTxCongestions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Tx congestions."
::= { pktSwchFrIfEntry 22 }
pktSwchFrIfRxCongestions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Rx congestions."
::= { pktSwchFrIfEntry 23 }
pktSwchFrIfTotDlciNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of DLCIs defined."
::= { pktSwchFrIfEntry 24 }
pktSwchFrCircuitSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchFrCircuitSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay Scratch Circuit Table includes configurable objects
provided by the PS that are not included in RFC 1315."
::= { pktSwchFr 5 }
pktSwchFrCircuitSEntry OBJECT-TYPE
SYNTAX PktSwchFrCircuitSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the RAD PS Frame Relay
Circuit Scratch Table."
INDEX { pktSwchFrCircuitIfIndexS,pktSwchFrCircuitIndexS }
::= { pktSwchFrCircuitSTable 1 }
PktSwchFrCircuitSEntry ::= SEQUENCE {
pktSwchFrCircuitIfIndexS
Integer32,
pktSwchFrCircuitIndexS
Integer32,
pktSwchFrCircuitDestProtS
INTEGER,
pktSwchFrCircuitDestIdS
DisplayString,
pktSwchFrCircuitBackIdS
DisplayString,
pktSwchFrCircuitTxCirIntervalS
Integer32,
pktSwchFrCircuitTxCommittedS
Integer32,
pktSwchFrCircuitTxExcessS
Integer32,
pktSwchFrCircuitRxCirIntervalS
Integer32,
pktSwchFrCircuitRxCommittedS
Integer32,
pktSwchFrCircuitRxExcessS
Integer32,
pktSwchFrCircuitFunnelIdS
Integer32,
pktSwchFrCircuitStatusS
INTEGER,
pktSwchFrCircuitExtendedDlciS
Integer32,
pktSwchFrCircuitTxPriorityS
Integer32,
pktSwchFrCircuitIsdnRoutIdS
Integer32
}
pktSwchFrCircuitIfIndexS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the ifIndex of the circuit, according to RFC 1573."
::= { pktSwchFrCircuitSEntry 1 }
pktSwchFrCircuitIndexS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This Index is the DLCI of the circuit."
::= { pktSwchFrCircuitSEntry 2 }
pktSwchFrCircuitDestProtS OBJECT-TYPE
SYNTAX INTEGER {
x25(1),
none(2),
hdlc(3),
async(4),
multiPoint(5),
rfc1490(6)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The protocol encapsulation, if any, on this DLCI.
The MPE protocol is a proprietary RAD protocol that enables
a generic HDLC device to have multiple connections over X.25
or Frame Relay."
::= { pktSwchFrCircuitSEntry 3 }
pktSwchFrCircuitDestIdS OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If the DLCI destination protocol is none or async, this field
has a value of an existing DLCI or async channel, respectively.
Otherwise, a value of zero is used."
::= { pktSwchFrCircuitSEntry 4 }
pktSwchFrCircuitBackIdS OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The backup DLCI which is used when the current DLCI goes inactive.
The destination protocol and destination id are the same as in the
current DLCI"
::= { pktSwchFrCircuitSEntry 5 }
pktSwchFrCircuitTxCirIntervalS OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Tx CIR interval in 1/10 seconds."
::= { pktSwchFrCircuitSEntry 6 }
pktSwchFrCircuitTxCommittedS OBJECT-TYPE
SYNTAX Integer32 (0..65000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Tx committed rate in bytes per interval."
::= { pktSwchFrCircuitSEntry 7 }
pktSwchFrCircuitTxExcessS OBJECT-TYPE
SYNTAX Integer32 (0..65000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Tx excess in bytes per interval."
::= { pktSwchFrCircuitSEntry 8 }
pktSwchFrCircuitRxCirIntervalS OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Rx CIR interval in 1/10 seconds."
::= { pktSwchFrCircuitSEntry 9 }
pktSwchFrCircuitRxCommittedS OBJECT-TYPE
SYNTAX Integer32 (0..65000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Rx committed rate in bytes per interval."
::= { pktSwchFrCircuitSEntry 10 }
pktSwchFrCircuitRxExcessS OBJECT-TYPE
SYNTAX Integer32 (0..65000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Rx excess in bytes per interval."
::= { pktSwchFrCircuitSEntry 11 }
pktSwchFrCircuitFunnelIdS OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The funnel ID."
::= { pktSwchFrCircuitSEntry 12 }
pktSwchFrCircuitStatusS OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of the circuit row in the Table."
::= { pktSwchFrCircuitSEntry 13 }
pktSwchFrCircuitExtendedDlciS OBJECT-TYPE
SYNTAX Integer32 (0..8388607)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The no. of the DLCI represented in 23 bits."
::= { pktSwchFrCircuitSEntry 14 }
pktSwchFrCircuitTxPriorityS OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DLCI TX Priority level. The levels are defined in the
pktSwchTxPriorityTable"
::= { pktSwchFrCircuitSEntry 15 }
pktSwchFrCircuitIsdnRoutIdS OBJECT-TYPE
SYNTAX Integer32 (0..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ISDN destination. ID in the ISDN routing table containing
the outgoing ISDN address for this DLCI.
Default value: 0 for no ISDN routing ID. "
::= { pktSwchFrCircuitSEntry 16 }
pktSwchFrCircuitATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchFrCircuitAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay Active Circuit Table includes statistics and configurable objects
provided by the PS that are not included in RFC 1315."
::= { pktSwchFr 6 }
pktSwchFrCircuitAEntry OBJECT-TYPE
SYNTAX PktSwchFrCircuitAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the RAD PS Frame Relay Circuit Active Table."
INDEX { pktSwchFrCircuitIfIndexA,pktSwchFrCircuitIndexA }
::= { pktSwchFrCircuitATable 1 }
PktSwchFrCircuitAEntry ::= SEQUENCE {
pktSwchFrCircuitIfIndexA
Integer32,
pktSwchFrCircuitIndexA
Integer32,
pktSwchFrCircuitDestProtA
INTEGER,
pktSwchFrCircuitDestIdA
DisplayString,
pktSwchFrCircuitBackIdA
DisplayString,
pktSwchFrCircuitTxCirIntervalA
Integer32,
pktSwchFrCircuitTxCommittedA
Integer32,
pktSwchFrCircuitTxExcessA
Integer32,
pktSwchFrCircuitRxCirIntervalA
Integer32,
pktSwchFrCircuitRxCommittedA
Integer32,
pktSwchFrCircuitRxExcessA
Integer32,
pktSwchFrCircuitFunnelIdA
Integer32,
pktSwchFrCircuitFunnelStat
DisplayString,
pktSwchFrCircuitTxCongDiscards
Counter32,
pktSwchFrCircuitDeTxFrames
Counter32,
pktSwchFrCircuitDeRxFrames
Counter32,
pktSwchFrCircuitFecnTxFrames
Counter32,
pktSwchFrCircuitBecnTxFrames
Counter32,
pktSwchFrCircuitCommRateViolTxFrames
Counter32,
pktSwchFrCircuitCommRateViolRxFrames
Counter32,
pktSwchFrCircuitExcessRateViolTxFrames
Counter32,
pktSwchFrCircuitExcessRateViolRxFrames
Counter32,
pktSwchFrCircuitState
INTEGER,
pktSwchFrCircuitExtendedDlciA
Integer32,
pktSwchFrCircuitTxPriorityA
Integer32,
pktSwchFrCircuitIsdnRoutIdA
Integer32
}
pktSwchFrCircuitIfIndexA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the ifIndex of the circuit, according to RFC 1573."
::= { pktSwchFrCircuitAEntry 1 }
pktSwchFrCircuitIndexA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This Index is the DLCI of the circuit."
::= { pktSwchFrCircuitAEntry 2 }
pktSwchFrCircuitDestProtA OBJECT-TYPE
SYNTAX INTEGER {
x25(1),
none(2),
hdlc(3),
async(4),
multiPoint(5),
rfc1490(6)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The protocol encapsulation, if any, on this DLCI.
The MPE protocol is a proprietary RAD protocol that enables
a generic HDLC device to have multiple connections over X.25
or Frame Relay."
::= { pktSwchFrCircuitAEntry 3 }
pktSwchFrCircuitDestIdA OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the DLCI destination protocol is none or async, this field
has a value of an existing DLCI or async channel, respectively.
Otherwise, a value of zero is used."
::= { pktSwchFrCircuitAEntry 4 }
pktSwchFrCircuitBackIdA OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The backup DLCI which is used when the current DLCI goes inactive.
The destination protocol and destination id are the same as in the
current DLCI"
::= { pktSwchFrCircuitAEntry 5 }
pktSwchFrCircuitTxCirIntervalA OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Tx CIR interval in 1/10 seconds."
::= { pktSwchFrCircuitAEntry 6 }
pktSwchFrCircuitTxCommittedA OBJECT-TYPE
SYNTAX Integer32 (0..65000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Tx committed rate in bytes per interval."
::= { pktSwchFrCircuitAEntry 7 }
pktSwchFrCircuitTxExcessA OBJECT-TYPE
SYNTAX Integer32 (0..65000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Tx excess in bytes per interval."
::= { pktSwchFrCircuitAEntry 8 }
pktSwchFrCircuitRxCirIntervalA OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Rx CIR interval in 1/10 seconds."
::= { pktSwchFrCircuitAEntry 9 }
pktSwchFrCircuitRxCommittedA OBJECT-TYPE
SYNTAX Integer32 (0..65000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Rx committed rate in bytes per interval."
::= { pktSwchFrCircuitAEntry 10 }
pktSwchFrCircuitRxExcessA OBJECT-TYPE
SYNTAX Integer32 (0..65000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Rx excess in bytes per interval."
::= { pktSwchFrCircuitAEntry 11 }
pktSwchFrCircuitFunnelIdA OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The funnel ID."
::= { pktSwchFrCircuitAEntry 12 }
pktSwchFrCircuitFunnelStat OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The funnel status."
::= { pktSwchFrCircuitAEntry 13 }
pktSwchFrCircuitTxCongDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames discarded because of Tx congestion."
::= { pktSwchFrCircuitAEntry 14 }
pktSwchFrCircuitDeTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of DE Tx frames."
::= { pktSwchFrCircuitAEntry 15 }
pktSwchFrCircuitDeRxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of DE Rx frames."
::= { pktSwchFrCircuitAEntry 16 }
pktSwchFrCircuitFecnTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of FECN Tx frames."
::= { pktSwchFrCircuitAEntry 17 }
pktSwchFrCircuitBecnTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of BECN Tx frames."
::= { pktSwchFrCircuitAEntry 18 }
pktSwchFrCircuitCommRateViolTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Tx committed rate violations in number of frames."
::= { pktSwchFrCircuitAEntry 19 }
pktSwchFrCircuitCommRateViolRxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Rx committed rate violations in number of frames."
::= { pktSwchFrCircuitAEntry 20 }
pktSwchFrCircuitExcessRateViolTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Tx excess rate violations in number of frames."
::= { pktSwchFrCircuitAEntry 21 }
pktSwchFrCircuitExcessRateViolRxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Rx excess rate violations in number of frames."
::= { pktSwchFrCircuitAEntry 22 }
pktSwchFrCircuitState OBJECT-TYPE
SYNTAX INTEGER {
new (1),
noState (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the particular virtual cir-
cuit is new or not."
::= { pktSwchFrCircuitAEntry 23 }
pktSwchFrCircuitExtendedDlciA OBJECT-TYPE
SYNTAX Integer32 (0..8388607)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The no. of the DLCI represented in 23 bits."
::= { pktSwchFrCircuitAEntry 24 }
pktSwchFrCircuitTxPriorityA OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DLCI TX Priority level. The levels are defined in the
pktSwchTxPriorityTable"
::= { pktSwchFrCircuitAEntry 25 }
pktSwchFrCircuitIsdnRoutIdA OBJECT-TYPE
SYNTAX Integer32 (0..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ISDN destination. ID in the ISDN routing table containing
the outgoing ISDN address for this DLCI.
Default value: 0 for no ISDN routing ID. "
::= { pktSwchFrCircuitAEntry 26 }
pktSwchFrFunnelSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchFrFunnelSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay Funnel Table defines the funnels that DLCIs may use."
::= { pktSwchFr 7 }
pktSwchFrFunnelSEntry OBJECT-TYPE
SYNTAX PktSwchFrFunnelSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the RAD PS Frame Relay Funnel Table."
INDEX { pktSwchFrFunnelIndexS }
::= { pktSwchFrFunnelSTable 1 }
PktSwchFrFunnelSEntry ::= SEQUENCE {
pktSwchFrFunnelIndexS
Integer32,
pktSwchFrFunnelSizeS
Integer32,
pktSwchFrFunnelHighWaterFramesS
Integer32,
pktSwchFrFunnelHighWaterBytesS
Integer32,
pktSwchFrFunnelGaugeTxRateS
Integer32,
pktSwchFrFunnelTransWindowS
Integer32,
pktSwchFrFunnelStatusS
INTEGER
}
pktSwchFrFunnelIndexS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the index of the funnel table."
::= { pktSwchFrFunnelSEntry 1 }
pktSwchFrFunnelSizeS OBJECT-TYPE
SYNTAX Integer32 (0..256)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of frames the funnel can store internally, where each
frame is 512 bytes."
::= { pktSwchFrFunnelSEntry 2 }
pktSwchFrFunnelHighWaterFramesS OBJECT-TYPE
SYNTAX Integer32 (0..256)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of frames the funnel can hold before it
expands and transmits all the data."
::= { pktSwchFrFunnelSEntry 3 }
pktSwchFrFunnelHighWaterBytesS OBJECT-TYPE
SYNTAX Integer32 (0..65000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of bytes the funnel can hold before it expands
and transmits all the data."
::= { pktSwchFrFunnelSEntry 4 }
pktSwchFrFunnelGaugeTxRateS OBJECT-TYPE
SYNTAX Integer32 (0..65000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The outgoing data rate in bytes per window of the funnel."
::= { pktSwchFrFunnelSEntry 5 }
pktSwchFrFunnelTransWindowS OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The transmission rate is measured during a sliding time window.
This parameter defines the window in 1/10 seconds."
::= { pktSwchFrFunnelSEntry 6 }
pktSwchFrFunnelStatusS OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this funnel table entry. The choices are those defined in the SNMPv2 Textual
Conventions for RowStatus. This will allow easy replacement of the INTEGER syntax with
the RowStatus textual convention SYNTAX."
::= { pktSwchFrFunnelSEntry 7 }
pktSwchFrFunnelATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchFrFunnelAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay Funnel Table defines the funnels that DLCIs may use."
::= { pktSwchFr 8 }
pktSwchFrFunnelAEntry OBJECT-TYPE
SYNTAX PktSwchFrFunnelAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the RAD PS Frame Relay Funnel Table."
INDEX { pktSwchFrFunnelIndexA }
::= { pktSwchFrFunnelATable 1 }
PktSwchFrFunnelAEntry ::= SEQUENCE {
pktSwchFrFunnelIndexA
Integer32,
pktSwchFrFunnelSizeA
Integer32,
pktSwchFrFunnelHighWaterFramesA
Integer32,
pktSwchFrFunnelHighWaterBytesA
Integer32,
pktSwchFrFunnelGaugeTxRateA
Integer32,
pktSwchFrFunnelTransWindowA
Integer32
}
pktSwchFrFunnelIndexA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the index of the funnel table."
::= { pktSwchFrFunnelAEntry 1 }
pktSwchFrFunnelSizeA OBJECT-TYPE
SYNTAX Integer32 (0..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames the funnel can store internally, where each frame is 512 bytes."
::= { pktSwchFrFunnelAEntry 2 }
pktSwchFrFunnelHighWaterFramesA OBJECT-TYPE
SYNTAX Integer32 (0..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of frames the funnel can hold before it expands and transmits all the data."
::= { pktSwchFrFunnelAEntry 3 }
pktSwchFrFunnelHighWaterBytesA OBJECT-TYPE
SYNTAX Integer32 (0..65000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of bytes the funnel can hold before it expands and transmits all the data."
::= { pktSwchFrFunnelAEntry 4 }
pktSwchFrFunnelGaugeTxRateA OBJECT-TYPE
SYNTAX Integer32 (0..65000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The outgoing data rate in bytes per window of the funnel."
::= { pktSwchFrFunnelAEntry 5 }
pktSwchFrFunnelTransWindowA OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmission rate is measured during a sliding time window. This parameter defines the
window in 1/10 seconds."
::= { pktSwchFrFunnelAEntry 6 }
pktSwchFrDlciMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchFrDlciMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay Dlci mapping Table maps the Dlci numbers.
For each long Dlci a short one is mapped.
A long Dlci is a Dlci which contains a Dlci header of 3 or
4 bytes instead of the regular 2 bytes.
The long Dlci number has values from 1024 to 8,388,607."
::= { pktSwchFr 9 }
pktSwchFrDlciMapEntry OBJECT-TYPE
SYNTAX PktSwchFrDlciMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each Dlci Map Table entry."
INDEX { pktSwchFrDlciMapPort, pktSwchFrDlciMapLongDlci }
::= { pktSwchFrDlciMapTable 1 }
PktSwchFrDlciMapEntry ::= SEQUENCE {
pktSwchFrDlciMapPort
Integer32,
pktSwchFrDlciMapLongDlci
Integer32,
pktSwchFrDlciMapShortDlci
Integer32,
pktSwchFrDlciMapStatus
INTEGER
}
pktSwchFrDlciMapPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frame Relay port no. : 1-8 for FPS-8, 1-4 for FPS-4,
1-3 for APS, 1-6 for SPS-6, 1-12 for SPS-12."
::= { pktSwchFrDlciMapEntry 1 }
pktSwchFrDlciMapLongDlci OBJECT-TYPE
SYNTAX Integer32 (0..8388607)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Long Dlci number.
For Dlci's of 4 octets, the long Dlci number has values
from 1024 to 8,388,607.
For Dlci's of 2 octets, the long Dlci number has values
of 16-991."
::= { pktSwchFrDlciMapEntry 2 }
pktSwchFrDlciMapShortDlci OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Short Dlci number. Legal values: 0 - 1023."
::= { pktSwchFrDlciMapEntry 3 }
pktSwchFrDlciMapStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of the map row in the Table.
The only value which can be set is: createRequest.
This value is set when a new long dlci is created."
::= { pktSwchFrDlciMapEntry 4 }
pktSwchMpe OBJECT IDENTIFIER ::= { radPS 9 }
pktSwchMpeSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchMpeSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MPE Table defines Scratch configuration parameters for the MPE protocol."
::= { pktSwchMpe 1 }
pktSwchMpeSEntry OBJECT-TYPE
SYNTAX PktSwchMpeSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the MPE Table."
INDEX { pktSwchMpeLinkNumberS }
::= { pktSwchMpeSTable 1 }
PktSwchMpeSEntry ::= SEQUENCE {
pktSwchMpeLinkNumberS
Integer32,
pktSwchMpeInactivityS
Integer32,
pktSwchMpeX25FacilitiesS
Integer32,
pktSwchMpeLocSubAddr1S
Integer32,
pktSwchMpeLocSubAddr2S
Integer32,
pktSwchMpeFlwCtrlDurS
Integer32,
pktSwchMpeFlwCtrlOptS
Integer32,
pktSwchMpeFlwCtrlBufS
Integer32,
pktSwchMpeInternalClkS
INTEGER
}
pktSwchMpeLinkNumberS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link number with which this entry is associated. This value
corresponds to pktSwchPhyInterfaceNumber. There is an entry for
each link for which the pktSwchPhyInterfaceProtocol is MPE."
::= { pktSwchMpeSEntry 1 }
pktSwchMpeInactivityS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The amount of time in minutes of inactivity that will cause the
session to disconnect."
::= { pktSwchMpeSEntry 2 }
pktSwchMpeX25FacilitiesS OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This specifies the X.25 facilities. The value is a sum of values
(powers of two), where each value in the sum represents an option.
The values that may be included in the sum and their meanings are:
0 No options
1 Packet size negotiation
2 Window size negotiation
4 Reverse charge."
::= { pktSwchMpeSEntry 3 }
pktSwchMpeLocSubAddr1S OBJECT-TYPE
SYNTAX Integer32 (1..99)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The first local subaddress."
::= { pktSwchMpeSEntry 4 }
pktSwchMpeLocSubAddr2S OBJECT-TYPE
SYNTAX Integer32 (1..99)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The second local subaddress."
::= { pktSwchMpeSEntry 5 }
pktSwchMpeFlwCtrlDurS OBJECT-TYPE
SYNTAX Integer32 (0..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The duration in 50 milliseconds of a hardware flow control signal. Default is 0"
::= { pktSwchMpeSEntry 6 }
pktSwchMpeFlwCtrlOptS OBJECT-TYPE
SYNTAX Integer32 (0..3)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This specifies the type of flow control of the MPE link. The value
is a sum of values (powers of two), where each value in the sum
represents an option. The values that may be included in the sum
and their meanings are:
0 No flow control
1 CTS flow control
2 Clock flow control."
::= { pktSwchMpeSEntry 7 }
pktSwchMpeFlwCtrlBufS OBJECT-TYPE
SYNTAX Integer32 (0..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of buffers that will be allocated for the MPE link."
::= { pktSwchMpeSEntry 8 }
pktSwchMpeInternalClkS OBJECT-TYPE
SYNTAX INTEGER {
r2400bps (1),
r4800bps (2),
r9600bps (3),
r14400bps(4),
r19200bps(5),
r38400bps(6),
r48Kbps (7),
r56Kbps (8),
r64Kbps (9),
r128Kbps (10),
r256Kbps (11),
r384Kbps (12),
r504Kbps (13),
r768Kbps (14),
r1008Kbps(15),
r1466Kbps(16),
r2016Kbps(17),
external(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The baud rate of the internal clock."
::= { pktSwchMpeSEntry 9 }
pktSwchMpeATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchMpeAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MPE Table defines Active configuration parameters for the MPE protocol."
::= { pktSwchMpe 2 }
pktSwchMpeAEntry OBJECT-TYPE
SYNTAX PktSwchMpeAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the MPE Table."
INDEX { pktSwchMpeLinkNumberA }
::= { pktSwchMpeATable 1 }
PktSwchMpeAEntry ::= SEQUENCE {
pktSwchMpeLinkNumberA
Integer32,
pktSwchMpeInactivityA
Integer32,
pktSwchMpeX25FacilitiesA
Integer32,
pktSwchMpeLocSubAddr1A
Integer32,
pktSwchMpeLocSubAddr2A
Integer32,
pktSwchMpeFlwCtrlDurA
Integer32,
pktSwchMpeFlwCtrlOptA
Integer32,
pktSwchMpeFlwCtrlBufA
Integer32,
pktSwchMpeInternalClkA
INTEGER,
pktSwchMpeCtsStatus
INTEGER
}
pktSwchMpeLinkNumberA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link number with which this entry is associated. This value
corresponds to pktSwchPhyInterfaceNumber. There is an entry for
each link for which the pktSwchPhyInterfaceProtocol is MPE."
::= { pktSwchMpeAEntry 1 }
pktSwchMpeInactivityA OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of time in minutes of inactivity that will cause the
session to disconnect."
::= { pktSwchMpeAEntry 2 }
pktSwchMpeX25FacilitiesA OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This specifies the X.25 facilities. The value is a sum of values
(powers of two), where each value in the sum represents an option.
The values that may be included in the sum and their meanings are:
0 No options
1 Packet size negotiation
2 Window size negotiation
4 Reverse charge."
::= { pktSwchMpeAEntry 3 }
pktSwchMpeLocSubAddr1A OBJECT-TYPE
SYNTAX Integer32 (1..99)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The first local subaddress."
::= { pktSwchMpeAEntry 4 }
pktSwchMpeLocSubAddr2A OBJECT-TYPE
SYNTAX Integer32 (1..99)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The second local subaddress."
::= { pktSwchMpeAEntry 5 }
pktSwchMpeFlwCtrlDurA OBJECT-TYPE
SYNTAX Integer32 (0..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The duration in 50 milliseconds of a hardware flow control signal."
::= { pktSwchMpeAEntry 6 }
pktSwchMpeFlwCtrlOptA OBJECT-TYPE
SYNTAX Integer32 (0..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This specifies the type of flow control of the MPE link. The value
is a sum of values (powers of two), where each value in the sum
represents an option. The values that may be included in the sum
and their meanings are:
0 No flow control
1 CTS flow control
2 Clock flow control."
::= { pktSwchMpeAEntry 7 }
pktSwchMpeFlwCtrlBufA OBJECT-TYPE
SYNTAX Integer32 (0..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of buffers that will be allocated for the MPE link."
::= { pktSwchMpeAEntry 8 }
pktSwchMpeInternalClkA OBJECT-TYPE
SYNTAX INTEGER {
r2400bps (1),
r4800bps (2),
r9600bps (3),
r14400bps(4),
r19200bps(5),
r38400bps(6),
r48Kbps (7),
r56Kbps (8),
r64Kbps (9),
r128Kbps (10),
r256Kbps (11),
r384Kbps (12),
r504Kbps (13),
r768Kbps (14),
r1008Kbps(15),
r1466Kbps(16),
r2016Kbps(17),
external(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The baud rate of the internal clock."
::= { pktSwchMpeAEntry 9 }
pktSwchMpeCtsStatus OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CTS status."
::= { pktSwchMpeAEntry 10 }
pktSwchMpeAidSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchMpeAidSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The AID Table defines Scratch configuration parameters for the
logical connections (Address Id)."
::= { pktSwchMpe 3 }
pktSwchMpeAidSEntry OBJECT-TYPE
SYNTAX PktSwchMpeAidSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the MPE Table."
INDEX { ifIndex, pktSwchMpeAddressIdS }
::= { pktSwchMpeAidSTable 1 }
PktSwchMpeAidSEntry ::= SEQUENCE {
pktSwchMpeAddressIdS
Integer32,
pktSwchMpeAidMainTypeS
INTEGER,
pktSwchMpeAidMainIdS
Integer32,
pktSwchMpeAidMainSubIdS
Integer32,
pktSwchMpeAidBackupTypeS
INTEGER,
pktSwchMpeAidBackupIdS
Integer32,
pktSwchMpeAidBackupSubIdS
Integer32,
pktSwchMpeAidStatusS
INTEGER
}
pktSwchMpeAddressIdS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Address Id (AID) with which this entry is associated."
::= { pktSwchMpeAidSEntry 1 }
pktSwchMpeAidMainTypeS OBJECT-TYPE
SYNTAX INTEGER {
x25Svc(1),
x25Pvc(2),
fr(3),
innerCom(4),
notActive(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The protocol with which the AID is communicating."
::= { pktSwchMpeAidSEntry 2 }
pktSwchMpeAidMainIdS OBJECT-TYPE
SYNTAX Integer32 (0..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The link number of the protocol with which the AID is communicating.
The link number of the protocol with which the AID is communicating.
For X.25 SVC this number is Any Autocall ID (Pre-defined) ,
values: 1..200
For X.25 PVC this number is a local PVC that its source link has
already been set to the current link with a prefix of N.
values: 1..200
For FR this number is any Frame Relay link number (Pre-defined),
values: 1..12
For Inner communication this number is an HDLC or MPE link number
(Pre-defined), values: 1..12
For notActive this number is 0."
::= { pktSwchMpeAidSEntry 3 }
pktSwchMpeAidMainSubIdS OBJECT-TYPE
SYNTAX Integer32 (0..991)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DLCI with which the AID is communicating.
Sub ID is used only when Type is Frame Relay or Inner Comm.
The DLCI or destination AID with which the current AID is communicating.
If type is: Frame Relay PVC:
Sub ID must be an existing DLCI, 16-991.
(The DLCI's destination protocol has to be predefined to MPE).
If type is: Inner Communication:
In case of an HDLC link, Sub ID must be 0.
In case of an MPE link, Sub ID must be in AID permitted range.
For notActive this number is 0."
::= { pktSwchMpeAidSEntry 4 }
pktSwchMpeAidBackupTypeS OBJECT-TYPE
SYNTAX INTEGER {
x25Svc(1),
x25Pvc(2),
fr(3),
innerCom(4),
notActive(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The protocol with which the AID is communicating on the backup."
::= { pktSwchMpeAidSEntry 5 }
pktSwchMpeAidBackupIdS OBJECT-TYPE
SYNTAX Integer32 (0..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The link number of the protocol with which the AID is communicating
on the backup.
The link number of the protocol with which the AID is communicating.
For X.25 SVC this number is Any Autocall ID (Pre-defined) ,
values: 1..200
For X.25 PVC this number is a local PVC that its source link has
already been set to the current link with a prefix of N.
values: 1..200
For FR this number is any Frame Relay link number (Pre-defined),
values: 1..12
For Inner communication this number is an HDLC or MPE link number
(Pre-defined), values: 1..12
For notActive this number is 0."
::= { pktSwchMpeAidSEntry 6 }
pktSwchMpeAidBackupSubIdS OBJECT-TYPE
SYNTAX Integer32 (0..991)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DLCI with which the AID is communicating.
Sub ID is used only when Type is Frame Relay or Inner Comm.
The DLCI or destination AID with which the current AID is communicating.
If type is: Frame Relay PVC:
Sub ID must be an existing DLCI, 16-991.
(The DLCI's destination protocol has to be predefined to MPE).
If type is: Inner Communication:
In case of an HDLC link, Sub ID must be 0.
In case of an MPE link, Sub ID must be in AID permitted range.
For notActive this number is 0."
::= { pktSwchMpeAidSEntry 7 }
pktSwchMpeAidStatusS OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this Address Id table entry."
::= { pktSwchMpeAidSEntry 8 }
pktSwchMpeAidATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchMpeAidAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The AID Table defines Active configuration parameters for the
logical connections (Address Id)."
::= { pktSwchMpe 4 }
pktSwchMpeAidAEntry OBJECT-TYPE
SYNTAX PktSwchMpeAidAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the MPE Table."
INDEX { ifIndex, pktSwchMpeAddressIdA }
::= { pktSwchMpeAidATable 1 }
PktSwchMpeAidAEntry ::= SEQUENCE {
pktSwchMpeAddressIdA
Integer32,
pktSwchMpeAidMainTypeA
INTEGER,
pktSwchMpeAidMainIdA
Integer32,
pktSwchMpeAidMainSubIdA
Integer32,
pktSwchMpeAidBackupTypeA
INTEGER,
pktSwchMpeAidBackupIdA
Integer32,
pktSwchMpeAidBackupSubIdA
Integer32,
pktSwchMpeAidConn
INTEGER,
pktSwchMpeAidFlwCtrl
INTEGER
}
pktSwchMpeAddressIdA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Address Id (AID) with which this entry is associated."
::= { pktSwchMpeAidAEntry 1 }
pktSwchMpeAidMainTypeA OBJECT-TYPE
SYNTAX INTEGER {
x25Svc(1),
x25Pvc(2),
fr(3),
innerCom(4),
notActive(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The protocol with which the AID is communicating."
::= { pktSwchMpeAidAEntry 2 }
pktSwchMpeAidMainIdA OBJECT-TYPE
SYNTAX Integer32 (0..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link number of the protocol with which the AID is communicating.
The link number of the protocol with which the AID is communicating.
For X.25 SVC this number is Any Autocall ID (Pre-defined) ,
values: 1..200
For X.25 PVC this number is a local PVC that its source link has
already been set to the current link with a prefix of N.
values: 1..200
For FR this number is any Frame Relay link number (Pre-defined),
values: 1..12
For Inner communication this number is an HDLC or MPE link number
(Pre-defined), values: 1..12
For notActive this number is 0."
::= { pktSwchMpeAidAEntry 3 }
pktSwchMpeAidMainSubIdA OBJECT-TYPE
SYNTAX Integer32 (0..991)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DLCI with which the AID is communicating.
Sub ID is used only when Type is Frame Relay or Inner Comm.
The DLCI or destination AID with which the current AID is communicating.
If type is: Frame Relay PVC:
Sub ID must be an existing DLCI, 16-991.
(The DLCI's destination protocol has to be predefined to MPE).
If type is: Inner Communication:
In case of an HDLC link, Sub ID must be 0.
In case of an MPE link, Sub ID must be in AID permitted range.
For notActive this number is 0."
::= { pktSwchMpeAidAEntry 4 }
pktSwchMpeAidBackupTypeA OBJECT-TYPE
SYNTAX INTEGER {
x25Svc(1),
x25Pvc(2),
fr(3),
innerCom(4),
notActive(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The protocol with which the AID is communicating on the backup."
::= { pktSwchMpeAidAEntry 5 }
pktSwchMpeAidBackupIdA OBJECT-TYPE
SYNTAX Integer32 (0..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link number of the protocol with which the AID is communicating
on the backup.
The link number of the protocol with which the AID is communicating.
For X.25 SVC this number is Any Autocall ID (Pre-defined) ,
values: 1..200
For X.25 PVC this number is a local PVC that its source link has
already been set to the current link with a prefix of N.
values: 1..200
For FR this number is any Frame Relay link number (Pre-defined),
values: 1..12
For Inner communication this number is an HDLC or MPE link number
(Pre-defined), values: 1..12
For notActive this number is 0."
::= { pktSwchMpeAidAEntry 6 }
pktSwchMpeAidBackupSubIdA OBJECT-TYPE
SYNTAX Integer32 (0..991)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DLCI with which the AID is communicating.
Sub ID is used only when Type is Frame Relay or Inner Comm.
The DLCI or destination AID with which the current AID is communicating.
If type is: Frame Relay PVC:
Sub ID must be an existing DLCI, 16-991.
(The DLCI's destination protocol has to be predefined to MPE).
If type is: Inner Communication:
In case of an HDLC link, Sub ID must be 0.
In case of an MPE link, Sub ID must be in AID permitted range.
For notActive this number is 0."
::= { pktSwchMpeAidAEntry 7 }
pktSwchMpeAidConn OBJECT-TYPE
SYNTAX INTEGER {
disconnect(1),
connect(2),
pvc(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The connectivity status of the AID."
::= { pktSwchMpeAidAEntry 8 }
pktSwchMpeAidFlwCtrl OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Flow Control status of the AID."
::= { pktSwchMpeAidAEntry 9 }
-- The PS Slip Group contains Slip Scratch and Active Tables,
-- which contain configuration for Slip links
pktSwchSlip OBJECT IDENTIFIER ::= { radPS 10 }
pktSwchSlipSTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchSlipSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Scratch Slip Table contains configuration information for
Slip links"
::= { pktSwchSlip 1 }
pktSwchSlipSEntry OBJECT-TYPE
SYNTAX PktSwchSlipSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the RAD Slip Table."
INDEX { pktSwchSlipLinkNumberS }
::= { pktSwchSlipSTable 1 }
PktSwchSlipSEntry ::= SEQUENCE {
pktSwchSlipLinkNumberS
Integer32,
pktSwchSlipSpeedS
INTEGER,
pktSwchSlipFCOptionS
Integer32,
pktSwchSlipStopBitsS
INTEGER,
pktSwchSlipBitPerCharS
Integer32,
pktSwchSlipParityS
INTEGER,
pktSwchSlipIpAddressS
IpAddress,
pktSwchSlipIpMaskS
IpAddress,
pktSwchSlipDefEncapsTypeS
INTEGER,
pktSwchSlipDefDestinationS
DisplayString
}
pktSwchSlipLinkNumberS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link number with which this entry is associated. This value
corresponds to pktSwchPhyInterfaceIfIndex. There is an entry for
each link for which the pktSwchPhyInterfaceProtocol is Slip."
::= { pktSwchSlipSEntry 1 }
pktSwchSlipSpeedS OBJECT-TYPE
SYNTAX INTEGER {
s110bps (1),
s300bps (2),
s1200bps (3),
s600bps (4),
s75bps (5),
s150bps (6),
s2400bps (12),
s4800bps (13),
s9600bps (14),
s19200bps (15),
s38400bps (19),
s57600bps (20),
s115200bps(21)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter determines the rate of data transmission to
and from the DTE."
::= { pktSwchSlipSEntry 2 }
pktSwchSlipFCOptionS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION " The flow control options
0 - No HARDWARE flow control
1..254 - Timer value (in 50ms intervals),
when timer expires, flow control stops
255 - The timer is not used"
::= { pktSwchSlipSEntry 3 }
pktSwchSlipStopBitsS OBJECT-TYPE
SYNTAX INTEGER {
one (1),
two (2),
oneAndHalf(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates the number of stop bits per character
supported by the PAD.
The options are either (1) one stop bit, (2) two stop bits,
or (3) 1.5 stop bits."
::= { pktSwchSlipSEntry 4 }
pktSwchSlipBitPerCharS OBJECT-TYPE
SYNTAX Integer32 (5..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of data bits per character supported by the Slip
link."
::= { pktSwchSlipSEntry 5 }
pktSwchSlipParityS OBJECT-TYPE
SYNTAX INTEGER {
space(1),
mark(2),
even(3),
odd(4),
none(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry selects the type of parity to be checked and or
generated by the PAD when radSPSProfileParTreat is a value
other than 255.
The options are (1) space parity, (2) mark parity,
(3) even parity, (4) odd parity, or (255) no parity."
::= { pktSwchSlipSEntry 6 }
pktSwchSlipIpAddressS OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"The IP address connected to this Slip port. This variable is
used when an automatic connection is done by the IP Routing."
::= { pktSwchSlipSEntry 7 }
pktSwchSlipIpMaskS OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"The IP mask. This variable is
used when an automatic connection by the IP Routing is done."
::= { pktSwchSlipSEntry 8 }
pktSwchSlipDefEncapsTypeS OBJECT-TYPE
SYNTAX INTEGER {
slip (1),
x25SVC (2),
x25PVC (3),
frameRelay (4),
hdlc (5),
none (255)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Destination protocol of this Slip port. This variable is used
when a direct connection without IP Routing is done."
::= { pktSwchSlipSEntry 9 }
pktSwchSlipDefDestinationS OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Default destination for this Slip port.
This variable is used when a direct connection without
IP Routing is done.
Possible values:
Default : Not Used.
X.25 PVC: Port:LCN or a pre defined PVC number
X.25 SVC: X.25 Addr or cid followed by a predefined Call ID number
Frame Relay: Port:DLCI
HDLC: HDLC Port Number
SLIP: SLIP Channel Number"
::= { pktSwchSlipSEntry 10 }
-- The active slip table
--
pktSwchSlipATable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchSlipAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Active Slip Table contains configuration information for
Slip links"
::= { pktSwchSlip 2 }
pktSwchSlipAEntry OBJECT-TYPE
SYNTAX PktSwchSlipAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the RAD Slip Table."
INDEX { pktSwchSlipLinkNumberA }
::= { pktSwchSlipATable 1 }
PktSwchSlipAEntry ::= SEQUENCE {
pktSwchSlipLinkNumberA
Integer32,
pktSwchSlipSpeedA
INTEGER,
pktSwchSlipFCOptionA
Integer32,
pktSwchSlipStopBitsA
INTEGER,
pktSwchSlipBitPerCharA
Integer32,
pktSwchSlipParityA
INTEGER,
pktSwchSlipIpAddressA
IpAddress,
pktSwchSlipIpMaskA
IpAddress,
pktSwchSlipDefEncapsTypeA
INTEGER,
pktSwchSlipDefDestinationA
DisplayString
}
pktSwchSlipLinkNumberA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link number with which this entry is associated. This value
corresponds to pktSwchPhyInterfaceIfIndex. There is an entry for
each link for which the pktSwchPhyInterfaceProtocol is Slip."
::= { pktSwchSlipAEntry 1 }
pktSwchSlipSpeedA OBJECT-TYPE
SYNTAX INTEGER {
s110bps (1),
s300bps (2),
s1200bps (3),
s600bps (4),
s75bps (5),
s150bps (6),
s2400bps (12),
s4800bps (13),
s9600bps (14),
s19200bps (15),
s38400bps (19),
s57600bps (20),
s115200bps(21)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter determines the rate of data transmission to
and from the DTE."
::= { pktSwchSlipAEntry 2 }
pktSwchSlipFCOptionA OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The flow control options
0 - No HARDWARE flow control
1..254 - Timer value (in 50ms intervals),
when timer expires, flow control stops
255 - The timer is not used"
::= { pktSwchSlipAEntry 3 }
pktSwchSlipStopBitsA OBJECT-TYPE
SYNTAX INTEGER {
one (1),
two (2),
oneAndHalf(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the number of stop bits per character
supported by the PAD.
The options are either (1) one stop bit, (2) two stop bits,
or (3) 1.5 stop bits."
::= { pktSwchSlipAEntry 4 }
pktSwchSlipBitPerCharA OBJECT-TYPE
SYNTAX Integer32 (5..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data bits per character supported by the Slip
link."
::= { pktSwchSlipAEntry 5 }
pktSwchSlipParityA OBJECT-TYPE
SYNTAX INTEGER {
space(1),
mark(2),
even(3),
odd(4),
none(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry selects the type of parity to be checked and or
generated by the PAD when radSPSProfileParTreat is a value
other than 255.
The options are (1) space parity, (2) mark parity,
(3) even parity, (4) odd parity, or (255) no parity."
::= { pktSwchSlipAEntry 6 }
pktSwchSlipIpAddressA OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The IP address connected to this Slip port."
::= { pktSwchSlipAEntry 7 }
pktSwchSlipIpMaskA OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The IP mask."
::= { pktSwchSlipAEntry 8 }
pktSwchSlipDefEncapsTypeA OBJECT-TYPE
SYNTAX INTEGER {
slip (1),
x25SVC (2),
x25PVC (3),
frameRelay (4),
hdlc (5),
none (255)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Destination protocol of this Slip port."
::= { pktSwchSlipAEntry 9 }
pktSwchSlipDefDestinationA OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Default destination for this Slip port.
This variable is used when a direct connection without
IP Routing is done.
Possible values:
Default : Not Used.
X.25 PVC: Port:LCN or a pre defined PVC number
X.25 SVC: X.25 Addr or cid followed by a predefined Call ID number
Frame Relay: Port:DLCI
HDLC: HDLC Port Number
SLIP: SLIP Channel Number"
::= { pktSwchSlipAEntry 10 }
pktSwchSna OBJECT IDENTIFIER ::= { radPS 11}
pktSwchSnaSDLCLinkTableS OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchSnaSDLCLinkEntryS
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SDLC Link Table defines the SDLC links configured on the PS."
::= { pktSwchSna 1 }
pktSwchSnaSDLCLinkEntryS OBJECT-TYPE
SYNTAX PktSwchSnaSDLCLinkEntryS
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SDLC Link Entry defines the contents of each link in the SDLC Link Table."
INDEX {ifIndex }
::= { pktSwchSnaSDLCLinkTableS 1 }
PktSwchSnaSDLCLinkEntryS ::= SEQUENCE {
pktSwchSnaSDLCLinkTypeS
INTEGER,
pktSwchSnaSDLCLinkPUSharedS
INTEGER,
pktSwchSnaSDLCLinkDuplexPhyS
INTEGER,
pktSwchSnaSDLCLinkflagsS
Integer32,
pktSwchSnaSDLCLinkDuplexS
INTEGER,
pktSwchSnaSDLCLinkClockS
INTEGER,
pktSwchSnaSDLCLinkNRZS
INTEGER
}
pktSwchSnaSDLCLinkTypeS OBJECT-TYPE
SYNTAX INTEGER{
primary(1),
secondary(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter identifies whether this link operates as
TPAD(Primary) or HPAD(Secondary) SDLC device."
::= { pktSwchSnaSDLCLinkEntryS 1 }
pktSwchSnaSDLCLinkPUSharedS OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether the link participates with more than
one PU or not."
::= { pktSwchSnaSDLCLinkEntryS 2 }
pktSwchSnaSDLCLinkDuplexPhyS OBJECT-TYPE
SYNTAX INTEGER {
half (1),
full (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter describes whether the physical level of the
SDLC line is half or full duplex."
::= { pktSwchSnaSDLCLinkEntryS 3 }
pktSwchSnaSDLCLinkflagsS OBJECT-TYPE
SYNTAX Integer32 (1..15)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of flags between frames."
::= { pktSwchSnaSDLCLinkEntryS 4 }
pktSwchSnaSDLCLinkDuplexS OBJECT-TYPE
SYNTAX INTEGER {
twoWayAlter (1),
twoWaySimul (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This parameter shows wether the link level is Two Way Alternate
or Two Way Simultaneous."
::= { pktSwchSnaSDLCLinkEntryS 5 }
pktSwchSnaSDLCLinkClockS OBJECT-TYPE
SYNTAX INTEGER {
r2400bps(1),
r4800bps(2),
r9600Bps(3),
r14400bps(4),
r19200bps(5),
r38400bps(6),
r48000bps(7),
r56000bps(8),
r64000bps(9),
r128000bps(10),
r256000bps(11),
r384000bps(12),
r504000bps(13),
r768000bps(14),
r1008000bps(15),
r1466000bps(16),
r2016000bps(17),
external(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This parameter defines the link clock rate "
::= { pktSwchSnaSDLCLinkEntryS 6 }
pktSwchSnaSDLCLinkNRZS OBJECT-TYPE
SYNTAX INTEGER {
nrzFlags(1),
nrziFlags(2),
nrzIdle(3),
nrziIdle(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This parameter describes the following combinations of NRZ,
NRZI with FLAGS or IDLE between frames:
Legal values:
1 - NRZ with FLAGs between frames. RTS is Constant
2 - NRZI with FLAGs between frames. RTS is Constant.
3 - NRZ with IDLE between frames. RTS is Controlled.
4 - NRZI with IDLE between frames. RTS is Controlled."
::={ pktSwchSnaSDLCLinkEntryS 7}
pktSwchSnaSDLCLinkTableA OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchSnaSDLCLinkEntryA
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SDLC Link Table defines the SDLC links configured on the SPS."
::= { pktSwchSna 2 }
pktSwchSnaSDLCLinkEntryA OBJECT-TYPE
SYNTAX PktSwchSnaSDLCLinkEntryA
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SDLC Link Entry defines the contents of each link in the SDLC Link Table."
INDEX {ifIndex }
::= { pktSwchSnaSDLCLinkTableA 1 }
PktSwchSnaSDLCLinkEntryA ::= SEQUENCE {
pktSwchSnaSDLCLinkTypeA
INTEGER,
pktSwchSnaSDLCLinkPUSharedA
INTEGER,
pktSwchSnaSDLCLinkDuplexPhyA
INTEGER,
pktSwchSnaSDLCLinkflagsA
Integer32,
pktSwchSnaSDLCLinkDuplexA
INTEGER,
pktSwchSnaSDLCLinkClockA
INTEGER,
pktSwchSnaSDLCLinkNRZA
INTEGER,
pktSwchSnaSDLCLinkStatFrames
Counter32,
pktSwchSnaSDLCLinkStatErrors
Counter32,
pktSwchSnaSDLCLinkStatInvalidAddresses
Counter32,
pktSwchSnaSDLCLinkStatShortFrames
Counter32
}
pktSwchSnaSDLCLinkTypeA OBJECT-TYPE
SYNTAX INTEGER{
primary(1),
secondary(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter identifies whether this link operates as
TPAD(Primary) or HPAD(Secondary) SDLC device."
::= { pktSwchSnaSDLCLinkEntryA 1 }
pktSwchSnaSDLCLinkPUSharedA OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter defines whether the link participates with more
than one PU or not."
::= { pktSwchSnaSDLCLinkEntryA 2 }
pktSwchSnaSDLCLinkDuplexPhyA OBJECT-TYPE
SYNTAX INTEGER {
half (1),
full (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter describes whether the physical level of the
SDLC line is half or full duplex."
::= { pktSwchSnaSDLCLinkEntryA 3 }
pktSwchSnaSDLCLinkflagsA OBJECT-TYPE
SYNTAX Integer32 (1..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of flags between frames."
::= { pktSwchSnaSDLCLinkEntryA 4 }
pktSwchSnaSDLCLinkDuplexA OBJECT-TYPE
SYNTAX INTEGER {
twoWayAlter (1),
twoWaySimul (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" This parameter shows wether the link level is Two Way Alternate
or Two Way Simultaneous."
::= { pktSwchSnaSDLCLinkEntryA 5 }
pktSwchSnaSDLCLinkClockA OBJECT-TYPE
SYNTAX INTEGER {
r2400bps(1),
r4800bps(2),
r9600Bps(3),
r14400bps(4),
r19200bps(5),
r38400bps(6),
r48000bps(7),
r56000bps(8),
r64000bps(9),
r128000bps(10),
r256000bps(11),
r384000bps(12),
r504000bps(13),
r768000bps(14),
r1008000bps(15),
r1466000bps(16),
r2016000bps(17),
external(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" This parameter defines the link clock rate."
::= { pktSwchSnaSDLCLinkEntryA 6 }
pktSwchSnaSDLCLinkNRZA OBJECT-TYPE
SYNTAX INTEGER {
nrzFlags(1),
nrziFlags(2),
nrzIdle(3),
nrziIdle(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" This parameter describes the following combinations of NRZ,
NRZI with FLAGS or IDLE between frames:
Legal values:
1 - NRZ with FLAGs between frames. RTS is Constant
2 - NRZI with FLAGs between frames. RTS is Constant.
3 - NRZ with IDLE between frames. RTS is Controlled.
4 - NRZI with IDLE between frames. RTS is Controlled."
::={ pktSwchSnaSDLCLinkEntryA 7}
pktSwchSnaSDLCLinkStatFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received or transmitted via this link "
::= { pktSwchSnaSDLCLinkEntryA 8 }
pktSwchSnaSDLCLinkStatErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of error frames received. "
::= { pktSwchSnaSDLCLinkEntryA 9}
pktSwchSnaSDLCLinkStatInvalidAddresses OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames with wrong address received by this link. "
::= { pktSwchSnaSDLCLinkEntryA 10}
pktSwchSnaSDLCLinkStatShortFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of short frames received by this link. "
::= { pktSwchSnaSDLCLinkEntryA 11}
pktSwchSnaPUTableS OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchSnaPUEntryS
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SDLC PU table defines the PUs configured on the PS."
::= { pktSwchSna 3 }
pktSwchSnaPUEntryS OBJECT-TYPE
SYNTAX PktSwchSnaPUEntryS
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SDLC PU Entry defines the contents of each PU in the
SDLC PU Table."
INDEX {pktSwchSnaPUNumberS}
::= { pktSwchSnaPUTableS 1 }
PktSwchSnaPUEntryS ::= SEQUENCE {
pktSwchSnaPUNumberS
Integer32,
pktSwchSnaPUXIDProcessingS
INTEGER,
pktSwchSnaPUEnableS
INTEGER,
pktSwchSnaPULinkATypeS
INTEGER,
pktSwchSnaPULinkARoleS
INTEGER,
pktSwchSnaPULinkBTypeS
INTEGER,
pktSwchSnaPULinkBRoleS
INTEGER,
pktSwchSnaPUEntryStatusS
INTEGER
}
pktSwchSnaPUNumberS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter defines an identifier associated with the PU Entry
which is unique within the SPS"
::= { pktSwchSnaPUEntryS 1}
pktSwchSnaPUXIDProcessingS OBJECT-TYPE
SYNTAX INTEGER {
localXid(1),
end2EndSupNoAct(2),
end2EndNoSupNoAct(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Exchange Identification (XID) processing. The following values are legal:
1 - Local XID handling
2 - End-to-End XID handling, Support for NON-Activation XID
3 - End-to-End XID handling, NO Support for NON-Activation XID"
::= { pktSwchSnaPUEntryS 2}
pktSwchSnaPUEnableS OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The PU runs or not at this specific time"
::= { pktSwchSnaPUEntryS 3}
pktSwchSnaPULinkATypeS OBJECT-TYPE
SYNTAX INTEGER {
sdlc(1),
x25Qllc(2),
frameRelayLLC2(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The PU link A type."
::= { pktSwchSnaPUEntryS 4}
pktSwchSnaPULinkARoleS OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
secondary(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The PU role for link A. Note that the role of an SDLC PU may
not be changed. It is defined by the SDLC Link Type."
::= { pktSwchSnaPUEntryS 5}
pktSwchSnaPULinkBTypeS OBJECT-TYPE
SYNTAX INTEGER {
sdlc(1),
x25Qllc(2),
frameRelayLLC2(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The PU partner link B type"
::= { pktSwchSnaPUEntryS 6}
pktSwchSnaPULinkBRoleS OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
secondary(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The PU role for link B. Note that the role of an SDLC PU may
not be changed. It is defined by the SDLC Link Type."
::= { pktSwchSnaPUEntryS 7}
pktSwchSnaPUEntryStatusS OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this PU table entry.
This Set request will fail if there are any conflicts between any of
of the parameter values in any of the tables comprising this PU
definition "
::= {pktSwchSnaPUEntryS 8}
pktSwchSnaPUTableA OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchSnaPUEntryA
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SDLC PU table defines the PUs configured on the PS."
::= { pktSwchSna 4 }
pktSwchSnaPUEntryA OBJECT-TYPE
SYNTAX PktSwchSnaPUEntryA
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SDLC PU Entry defines the contents of each PU in the
SDLC PU Table."
INDEX {pktSwchSnaPUNumberA}
::= { pktSwchSnaPUTableA 1 }
PktSwchSnaPUEntryA ::= SEQUENCE {
pktSwchSnaPUNumberA
Integer32,
pktSwchSnaPUXIDProcessingA
INTEGER,
pktSwchSnaPUEnableA
INTEGER,
pktSwchSnaPULinkATypeA
INTEGER,
pktSwchSnaPULinkARoleA
INTEGER,
pktSwchSnaPULinkBTypeA
INTEGER,
pktSwchSnaPULinkBRoleA
INTEGER
}
pktSwchSnaPUNumberA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter defines an identifier associated with the PU Entry
which is unique within the SPS"
::= { pktSwchSnaPUEntryA 1}
pktSwchSnaPUXIDProcessingA OBJECT-TYPE
SYNTAX INTEGER {
localXid(1),
end2EndSupNoAct(2),
end2EndNoSupNoAct(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PU XID Processing"
::= { pktSwchSnaPUEntryA 2}
pktSwchSnaPUEnableA OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PU runs or not at this specific time"
::= { pktSwchSnaPUEntryA 3}
pktSwchSnaPULinkATypeA OBJECT-TYPE
SYNTAX INTEGER {
sdlc(1),
x25Qllc(2),
frameRelayLLC2(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PU link type"
::= { pktSwchSnaPUEntryA 4}
pktSwchSnaPULinkARoleA OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
secondary(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PU role for link A"
::= { pktSwchSnaPUEntryA 5}
pktSwchSnaPULinkBTypeA OBJECT-TYPE
SYNTAX INTEGER {
sdlc(1),
x25Qllc(2),
frameRelayLLC2(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PU partner link type"
::= { pktSwchSnaPUEntryA 6}
pktSwchSnaPULinkBRoleA OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
secondary(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PU role for link B"
::= { pktSwchSnaPUEntryA 7}
pktSwchSnaPUSdlcTableS OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchSnaPUSdlcEntryS
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines links for PUs running on SDLC link "
::= { pktSwchSna 5 }
pktSwchSnaPUSdlcEntryS OBJECT-TYPE
SYNTAX PktSwchSnaPUSdlcEntryS
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines parameters of a link for a PU running on an SDLC link "
INDEX {pktSwchSnaPUSdlcNumberS , pktSwchSnaPUSdlcSideS }
::= { pktSwchSnaPUSdlcTableS 1 }
PktSwchSnaPUSdlcEntryS ::= SEQUENCE {
pktSwchSnaPUSdlcNumberS
Integer32,
pktSwchSnaPUSdlcSideS
INTEGER,
pktSwchSnaPUSdlcAddressS
OCTET STRING,
pktSwchSnaPUSdlcIfIndexS
Integer32,
pktSwchSnaPUSdlcIdBlkS
OCTET STRING,
pktSwchSnaPUSdlcIdNumS
OCTET STRING,
pktSwchSnaPUSdlcMaxPiuSizeS
Integer32,
pktSwchSnaPUSdlcTxWindowS
Integer32,
pktSwchSnaPUSdlcGrpAddressS
OCTET STRING,
pktSwchSnaPUSdlcPollTimerS
Integer32,
pktSwchSnaPUSdlcXIDInitiationS
INTEGER,
pktSwchSnaPUSdlcEntryStatusS
INTEGER
}
pktSwchSnaPUSdlcNumberS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter defines an identifier associated with the PU Entry
SDLC side, which is unique within the SPS"
::= { pktSwchSnaPUSdlcEntryS 1}
pktSwchSnaPUSdlcSideS OBJECT-TYPE
SYNTAX INTEGER {
sideA(1),
sideB(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is this side A or side B of the PU definition "
::= { pktSwchSnaPUSdlcEntryS 2}
pktSwchSnaPUSdlcAddressS OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SNA SDLC PU address. Range: 0x00-0xFE "
::= { pktSwchSnaPUSdlcEntryS 3}
pktSwchSnaPUSdlcIfIndexS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ifIndex of the SDLC link"
::= { pktSwchSnaPUSdlcEntryS 4}
pktSwchSnaPUSdlcIdBlkS OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Part of the IBM device ID (the full ID is defined by the IDBLK and
the IDNUM). The Idblk is required for secondary PU with Local XID
handling. Up to 3 Hexadecimal digits, format: 0X XX."
::= {pktSwchSnaPUSdlcEntryS 5}
pktSwchSnaPUSdlcIdNumS OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..3))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Second part of the IBM device ID (the full ID is defined by the IDBLK and
the IDNUM). The Idnum is required for secondary PU with Local XID
handling. Up to 5 Hexadecimal digits, format: 0X XX XX."
::= {pktSwchSnaPUSdlcEntryS 6}
pktSwchSnaPUSdlcMaxPiuSizeS OBJECT-TYPE
SYNTAX Integer32 (137..7642)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum Path Information Size"
::= { pktSwchSnaPUSdlcEntryS 7}
pktSwchSnaPUSdlcTxWindowS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Window Size(in frames) used when sending from the SPS. Range: 1-7."
::= { pktSwchSnaPUSdlcEntryS 8}
pktSwchSnaPUSdlcGrpAddressS OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SNA Group address used by the SPS when sending polls (TPAD ONLY).
Range: 0x00-0xFE"
::= { pktSwchSnaPUSdlcEntryS 9}
pktSwchSnaPUSdlcPollTimerS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time in between polls in 50 millisecond increments (TPAD ONLY).
Range: 1-65535."
::= { pktSwchSnaPUSdlcEntryS 10}
pktSwchSnaPUSdlcXIDInitiationS OBJECT-TYPE
SYNTAX INTEGER{
notInitiate(1),
initiate(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is not applicable for PU with Local XID handling.
Legal values:
1 - Do not initiate an XID message.
2 - Initiate an XID message to SDLC."
::= { pktSwchSnaPUSdlcEntryS 11}
pktSwchSnaPUSdlcEntryStatusS OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
underCreation(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this PU Sdlc table entry.
In order to save this entry, set status to valid.
An underCreation value is set by the Agent when this entry is updated."
::= {pktSwchSnaPUSdlcEntryS 12}
pktSwchSnaPUSdlcTableA OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchSnaPUSdlcEntryA
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines links for PUs running on an SDLC link "
::= { pktSwchSna 6 }
pktSwchSnaPUSdlcEntryA OBJECT-TYPE
SYNTAX PktSwchSnaPUSdlcEntryA
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines parameters of link for PU running on an SDLC link "
INDEX {pktSwchSnaPUSdlcNumberA , pktSwchSnaPUSdlcSideA }
::= { pktSwchSnaPUSdlcTableA 1 }
PktSwchSnaPUSdlcEntryA ::= SEQUENCE {
pktSwchSnaPUSdlcNumberA
Integer32,
pktSwchSnaPUSdlcSideA
INTEGER,
pktSwchSnaPUSdlcAddressA
OCTET STRING,
pktSwchSnaPUSdlcIfIndexA
Integer32,
pktSwchSnaPUSdlcIdBlkA
OCTET STRING,
pktSwchSnaPUSdlcIdNumA
OCTET STRING,
pktSwchSnaPUSdlcMaxPiuSizeA
Integer32,
pktSwchSnaPUSdlcTxWindowA
Integer32,
pktSwchSnaPUSdlcGrpAddressA
OCTET STRING,
pktSwchSnaPUSdlcPollTimerA
Integer32,
pktSwchSnaPUSdlcXIDInitiationA
INTEGER
}
pktSwchSnaPUSdlcNumberA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter defines an identifier associated with the PU Entry
SDLC side, which is unique within the SPS"
::= { pktSwchSnaPUSdlcEntryA 1}
pktSwchSnaPUSdlcSideA OBJECT-TYPE
SYNTAX INTEGER {
sideA(1),
sideB(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is this side A or side B of the PU definition "
::= { pktSwchSnaPUSdlcEntryA 2}
pktSwchSnaPUSdlcAddressA OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SNA SDLC PU address. Range: 0x00-0xFE."
::= { pktSwchSnaPUSdlcEntryA 3}
pktSwchSnaPUSdlcIfIndexA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ifIndex of the SDLC link"
::= { pktSwchSnaPUSdlcEntryA 4}
pktSwchSnaPUSdlcIdBlkA OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..2))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Part of the IBM device ID (the full ID is defined by the IDBLK and
the IDNUM). The Idblk is required for secondary PU with Local XID
handling. Up to 3 Hexadecimal digits, format: 0X XX."
::= {pktSwchSnaPUSdlcEntryA 5}
pktSwchSnaPUSdlcIdNumA OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..3))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Second part of the IBM device ID (the full ID is defined by the IDBLK and
the IDNUM). The Idnum is required for secondary PU with Local XID
handling. Up to 5 Hexadecimal digits, format: 0X XX XX."
::= {pktSwchSnaPUSdlcEntryA 6}
pktSwchSnaPUSdlcMaxPiuSizeA OBJECT-TYPE
SYNTAX Integer32 (137..7642)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum Path Information Size"
::= {pktSwchSnaPUSdlcEntryA 7}
pktSwchSnaPUSdlcTxWindowA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Window Size(in frames) used when sending from the SPS.
Range: 1-7."
::= { pktSwchSnaPUSdlcEntryA 8}
pktSwchSnaPUSdlcGrpAddressA OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SNA Group address used by the SPS when sending polls (TPAD ONLY).
Range: 0x00-0xFE."
::= { pktSwchSnaPUSdlcEntryA 9}
pktSwchSnaPUSdlcPollTimerA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time in between polls in 50 millisecond increments (TPAD ONLY).
Range: 1-65535."
::= { pktSwchSnaPUSdlcEntryA 10}
pktSwchSnaPUSdlcXIDInitiationA OBJECT-TYPE
SYNTAX INTEGER{
notInitiate(1),
initiate(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter is not applicable for PU with Local XID handling.
Legal values:
1 - Do not initiate an XID message.
2 - Initiate an XID message to SDLC."
::= { pktSwchSnaPUSdlcEntryA 11}
pktSwchSnaPUSdlcStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchSnaPUSdlcStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Shows Link Statistics for PUs running on an SDLC link "
::= { pktSwchSna 7 }
pktSwchSnaPUSdlcStatEntry OBJECT-TYPE
SYNTAX PktSwchSnaPUSdlcStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Shows Link Statistics for PUs running on an SDLC link "
INDEX {pktSwchSnaPUSdlcStatNumber , pktSwchSnaPUSdlcStatSide }
::= { pktSwchSnaPUSdlcStatTable 1 }
PktSwchSnaPUSdlcStatEntry ::= SEQUENCE {
pktSwchSnaPUSdlcStatNumber
Integer32,
pktSwchSnaPUSdlcStatSide
INTEGER,
pktSwchSnaPUSdlcStatOctetsIn
Counter32,
pktSwchSnaPUSdlcStatOctetsOut
Counter32,
pktSwchSnaPUSdlcStatIFramesIn
Counter32,
pktSwchSnaPUSdlcStatIFramesOut
Counter32,
pktSwchSnaPUSdlcStatRRFramesIn
Counter32,
pktSwchSnaPUSdlcStatRRFramesOut
Counter32,
pktSwchSnaPUSdlcStatRNRFramesIn
Counter32,
pktSwchSnaPUSdlcStatRNRFramesOut
Counter32,
pktSwchSnaPUSdlcStatXIDsIn
Counter32,
pktSwchSnaPUSdlcStatXIDsOut
Counter32,
pktSwchSnaPUSdlcStatTESTsIn
Counter32,
pktSwchSnaPUSdlcStatTESTsOut
Counter32,
pktSwchSnaPUSdlcStatREJsIn
Counter32,
pktSwchSnaPUSdlcStatREJsOut
Counter32,
pktSwchSnaPUSdlcStatFRMRsIn
Counter32,
pktSwchSnaPUSdlcStatFRMRsOut
Counter32,
pktSwchSnaPUSdlcStatDISCsIn
Counter32,
pktSwchSnaPUSdlcStatDISCsOut
Counter32,
pktSwchSnaPUSdlcStatUAsIn
Counter32,
pktSwchSnaPUSdlcStatUAsOut
Counter32,
pktSwchSnaPUSdlcStatDMsIn
Counter32,
pktSwchSnaPUSdlcStatDMsOut
Counter32,
pktSwchSnaPUSdlcStatSNRMsIn
Counter32,
pktSwchSnaPUSdlcStatSNRMsOut
Counter32,
pktSwchSnaPUSdlcStatRetransmitsIn
Counter32,
pktSwchSnaPUSdlcStatRetransmitsOut
Counter32,
pktSwchSnaPUSdlcUpperState
INTEGER,
pktSwchSnaPUSdlcLowerState
INTEGER,
pktSwchSnaPUSdlcStatNRMStatus
INTEGER,
pktSwchSnaPUSdlcStatFlowCtlStatus
INTEGER
}
pktSwchSnaPUSdlcStatNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter defines an identifier associated with the PU Entry
SDLC side statistics, which is unique within the SPS"
::= { pktSwchSnaPUSdlcStatEntry 1}
pktSwchSnaPUSdlcStatSide OBJECT-TYPE
SYNTAX INTEGER {
sideA(1),
sideB(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is this side A or side B of the PU definition "
::= { pktSwchSnaPUSdlcStatEntry 2}
pktSwchSnaPUSdlcStatOctetsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 3}
pktSwchSnaPUSdlcStatOctetsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 4}
pktSwchSnaPUSdlcStatIFramesIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 5}
pktSwchSnaPUSdlcStatIFramesOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 6}
pktSwchSnaPUSdlcStatRRFramesIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 7}
pktSwchSnaPUSdlcStatRRFramesOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 8}
pktSwchSnaPUSdlcStatRNRFramesIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 9}
pktSwchSnaPUSdlcStatRNRFramesOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 10}
pktSwchSnaPUSdlcStatXIDsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 11}
pktSwchSnaPUSdlcStatXIDsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 12}
pktSwchSnaPUSdlcStatTESTsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 13}
pktSwchSnaPUSdlcStatTESTsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 14}
pktSwchSnaPUSdlcStatREJsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 15}
pktSwchSnaPUSdlcStatREJsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 16}
pktSwchSnaPUSdlcStatFRMRsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 17}
pktSwchSnaPUSdlcStatFRMRsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 18}
pktSwchSnaPUSdlcStatDISCsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 19}
pktSwchSnaPUSdlcStatDISCsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 20}
pktSwchSnaPUSdlcStatUAsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 21}
pktSwchSnaPUSdlcStatUAsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 22}
pktSwchSnaPUSdlcStatDMsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 23}
pktSwchSnaPUSdlcStatDMsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 24}
pktSwchSnaPUSdlcStatSNRMsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 25}
pktSwchSnaPUSdlcStatSNRMsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 26}
pktSwchSnaPUSdlcStatRetransmitsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 27}
pktSwchSnaPUSdlcStatRetransmitsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUSdlcStatEntry 28}
pktSwchSnaPUSdlcUpperState OBJECT-TYPE
SYNTAX INTEGER {
unbound(1),
bindPending(2),
unbindPend(3),
idle(4),
unattached(5),
attachPend(6),
detachPend(7),
udqosPending(8),
outconPend(9),
inconPending(10),
connResPend(11),
dataxfer(12),
userResetPend(13),
provRstPend(14),
rstResPend(15),
discon8Pend(16),
discon9Pend(17),
discon11Pend(18),
discon12Pend(19),
discon13Pend(20),
subsBindPnd(21),
noChange(22)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The internal DLPI state of the connection."
::= { pktSwchSnaPUSdlcStatEntry 29}
pktSwchSnaPUSdlcLowerState OBJECT-TYPE
SYNTAX INTEGER {
linkClosed(1),
disconnected(2),
linkOpening(3),
disconnecting(4),
frmrSent(5),
linkOpened(6),
localBusy(7),
rejection(8),
checkpointing(9),
cpLocalBusy(10),
cpRejection(11),
resetting(12),
remoteBusy(13),
lBusyRBusy(14),
rejLBusy(15),
rejRBusy(16),
cpRejLBusy(17),
cpClearing(18),
cpRejClr(19),
rejLbusyRbusy(20),
frmrReceived(21),
programError(22),
noChange(23)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The internal SDLC state of the connection."
::= { pktSwchSnaPUSdlcStatEntry 30}
pktSwchSnaPUSdlcStatNRMStatus OBJECT-TYPE
SYNTAX INTEGER {sync(1),notSync(2)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates if the link is in Normal Response Mode or not."
::= { pktSwchSnaPUSdlcStatEntry 31}
pktSwchSnaPUSdlcStatFlowCtlStatus OBJECT-TYPE
SYNTAX INTEGER {noRNR(1),txFlow(2), rxFlow(3), rxAndTx(4)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the flow control status of the PU interface."
::= { pktSwchSnaPUSdlcStatEntry 32}
pktSwchSnaPUSX25QllcTableS OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchSnaPUX25QllcEntryS
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines links for PUs running on a QLLC link "
::= {pktSwchSna 8 }
pktSwchSnaPUX25QllcEntryS OBJECT-TYPE
SYNTAX PktSwchSnaPUX25QllcEntryS
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines parameters for PU side running on SDLC link "
INDEX {pktSwchSnaPUX25QllcNumberS , pktSwchSnaPUX25QllcSideS }
::= { pktSwchSnaPUSX25QllcTableS 1 }
PktSwchSnaPUX25QllcEntryS ::= SEQUENCE {
pktSwchSnaPUX25QllcNumberS
Integer32,
pktSwchSnaPUX25QllcSideS
INTEGER,
pktSwchSnaPUX25QllcIdBlkS
OCTET STRING,
pktSwchSnaPUX25QllcIdNumS
OCTET STRING,
pktSwchSnaPUX25QllcXIDInitS
INTEGER,
pktSwchSnaPUX25QllcMaxPiuSizeS
Integer32,
pktSwchSnaPUX25QllcStationAddressS
OCTET STRING,
pktSwchSnaPUX25QllcInPasswordS
DisplayString,
pktSwchSnaPUX25QllcSubAddressS
Integer32,
pktSwchSnaPUX25QllcAutoCallS
INTEGER,
pktSwchSnaPUX25QllcCalledAddressS
OCTET STRING,
pktSwchSnaPUX25QllcCallUserDataFacilitiesS
DisplayString,
pktSwchSnaPUX25QllcEntryStatusS
INTEGER
}
pktSwchSnaPUX25QllcNumberS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter defines an identifier associated with the PU Entry
X25\QLLC side, which is unique within the SPS"
::= {pktSwchSnaPUX25QllcEntryS 1}
pktSwchSnaPUX25QllcSideS OBJECT-TYPE
SYNTAX INTEGER {
sideA(1),
sideB(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is there side A or B of the PU connection "
::= {pktSwchSnaPUX25QllcEntryS 2}
pktSwchSnaPUX25QllcIdBlkS OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Part of the IBM device ID (the full ID is defined by the IDBLK and
the IDNUM). The Idblk is required for secondary PU with Local XID
handling. Up to 3 Hexadecimal digits, format: 0X XX."
::= {pktSwchSnaPUX25QllcEntryS 3}
pktSwchSnaPUX25QllcIdNumS OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..3))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Second part of the IBM device ID (the full ID is defined by the IDBLK and
the IDNUM). The Idnum is required for secondary PU with Local XID
handling. Up to 5 Hexadecimal digits, format: 0X XX XX."
::= {pktSwchSnaPUX25QllcEntryS 4}
pktSwchSnaPUX25QllcXIDInitS OBJECT-TYPE
SYNTAX INTEGER {
notInitiate(1),
initiate(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is not applicable for PU with Local XID handling.
Legal values:
1 - Do not initiate an XID message.
2 - Initiate an XID message to QLLC."
::= {pktSwchSnaPUX25QllcEntryS 5}
pktSwchSnaPUX25QllcMaxPiuSizeS OBJECT-TYPE
SYNTAX Integer32 (137..7642)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum Path Information Size"
::= { pktSwchSnaPUX25QllcEntryS 6}
pktSwchSnaPUX25QllcStationAddressS OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"QLLC PU Link Station Address. Range: 0x01-0xFE.
This parameter is applicable only for PU with End-to-End XID handling,
Support for NON-Activation XID."
::= {pktSwchSnaPUX25QllcEntryS 7}
pktSwchSnaPUX25QllcInPasswordS OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..8))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A field matched with the call user data in call request packets for
purposes of security and correlation."
::= {pktSwchSnaPUX25QllcEntryS 8}
pktSwchSnaPUX25QllcSubAddressS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The X.25 Sub-address associated with the PU Entry for routing
incoming call indications. Range: 0-99."
::= {pktSwchSnaPUX25QllcEntryS 9}
pktSwchSnaPUX25QllcAutoCallS OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates whether the SPS automatically initiates
an X.25 call request or not."
::= {pktSwchSnaPUX25QllcEntryS 10}
pktSwchSnaPUX25QllcCalledAddressS OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..15))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination x.25 DTE address to which the SPS calls. Used with
AutoCall only."
::= {pktSwchSnaPUX25QllcEntryS 11}
pktSwchSnaPUX25QllcCallUserDataFacilitiesS OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..60))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The X.25 facilities and Call User Data which the SPS uses on
outgoing calls. AutoCall only.
Up to 60 Hexa-Decimal digits.
Each pair of digits represents a BYTE.
BYTE-0 BYTE-1 BYTE-2 ... BYTE-29 (30 Bytes maximum)
BYTE-0 for X.25 Facilities. BYTE-1 to BYTE-29 for Call User Data.
Facilities (BYTE-0) format: PW (Hexa-Decimal), where:
X.25 L3 Packet Size Negotiation : [P=1 YES] [P=0 NO].
X.25 L3 Packet Window Negotiation : [W=1 YES] [W=0 NO].
Legal Values for Facilities BYTE-0 : 10, 01, 11, 00 (Hex).
ATTENTION: a. Total number of digits in this field must be EVEN.
b. To clear this field, enter blanks or 00."
::= {pktSwchSnaPUX25QllcEntryS 12}
pktSwchSnaPUX25QllcEntryStatusS OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
underCreation(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this PU Qllc table entry.
In order to save this entry, set status to valid.
An underCreation value is set by the Agent when this entry is updated."
::= {pktSwchSnaPUX25QllcEntryS 13}
pktSwchSnaPUX25QllcTableA OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchSnaPUX25QllcEntryA
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines links for PUs running on a QLLC link "
::= { pktSwchSna 9 }
pktSwchSnaPUX25QllcEntryA OBJECT-TYPE
SYNTAX PktSwchSnaPUX25QllcEntryA
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines parameters for PU side running on an SDLC link "
INDEX {pktSwchSnaPUX25QllcNumberA , pktSwchSnaPUX25QllcSideA}
::= { pktSwchSnaPUX25QllcTableA 1 }
PktSwchSnaPUX25QllcEntryA ::= SEQUENCE {
pktSwchSnaPUX25QllcNumberA
Integer32,
pktSwchSnaPUX25QllcSideA
INTEGER,
pktSwchSnaPUX25QllcIdBlkA
OCTET STRING,
pktSwchSnaPUX25QllcIdNumA
OCTET STRING,
pktSwchSnaPUX25QllcXIDInitA
INTEGER,
pktSwchSnaPUX25QllcMaxPiuSizeA
Integer32,
pktSwchSnaPUX25QllcStationAddressA
OCTET STRING,
pktSwchSnaPUX25QllcInPasswordA
DisplayString,
pktSwchSnaPUX25QllcSubAddressA
Integer32,
pktSwchSnaPUX25QllcAutoCallA
INTEGER,
pktSwchSnaPUX25QllcCalledAddressA
OCTET STRING,
pktSwchSnaPUX25QllcCallUserDataFacilitiesA
DisplayString
}
pktSwchSnaPUX25QllcNumberA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter defines an identifier associated with the PU Entry
X25\QLLC side, which is unique within the SPS"
::= {pktSwchSnaPUX25QllcEntryA 1}
pktSwchSnaPUX25QllcSideA OBJECT-TYPE
SYNTAX INTEGER {
sideA(1),
sideB(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is there side A or B of the PU connection "
::= {pktSwchSnaPUX25QllcEntryA 2}
pktSwchSnaPUX25QllcIdBlkA OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..2))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Part of the IBM device ID (the full ID is defined by the IDBLK and
the IDNUM). The Idblk is required for secondary PU with Local XID
handling. Up to 3 Hexadecimal digits, format: 0X XX."
::= {pktSwchSnaPUX25QllcEntryA 3}
pktSwchSnaPUX25QllcIdNumA OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..3))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Second part of the IBM device ID (the full ID is defined by the IDBLK and
the IDNUM). The Idnum is required for secondary PU with Local XID
handling. Up to 5 Hexadecimal digits, format: 0X XX XX."
::= {pktSwchSnaPUX25QllcEntryA 4}
pktSwchSnaPUX25QllcXIDInitA OBJECT-TYPE
SYNTAX INTEGER {
notInitiate(1),
initiate(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter is not applicable for PU with Local XID handling.
Legal values:
1 - Do not initiate an XID message.
2 - Initiate an XID message to QLLC."
::= {pktSwchSnaPUX25QllcEntryA 5}
pktSwchSnaPUX25QllcMaxPiuSizeA OBJECT-TYPE
SYNTAX Integer32 (137..7642)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum Path Information Size"
::= { pktSwchSnaPUX25QllcEntryA 6}
pktSwchSnaPUX25QllcStationAddressA OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"QLLC PU Link Station Address. Range: 0x01-0xFE.
This parameter is applicable only for PU with End-to-End XID handling,
Support for NON-Activation XID."
::= {pktSwchSnaPUX25QllcEntryA 7}
pktSwchSnaPUX25QllcInPasswordA OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A field matched with the call user data in call request packets for
purposes of security and correlation."
::= {pktSwchSnaPUX25QllcEntryA 8}
pktSwchSnaPUX25QllcSubAddressA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The X.25 Sub-address associated with the PU Entry for routing
incoming call indications. Range: 0-99."
::= {pktSwchSnaPUX25QllcEntryA 9}
pktSwchSnaPUX25QllcAutoCallA OBJECT-TYPE
SYNTAX INTEGER{
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates whether the SPS automatically initiates
an X.25 call request or not."
::= {pktSwchSnaPUX25QllcEntryA 10}
pktSwchSnaPUX25QllcCalledAddressA OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..15))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The destination x.25 DTE address to which the SPS calls. Used
with AutoCall only."
::= {pktSwchSnaPUX25QllcEntryA 11}
pktSwchSnaPUX25QllcCallUserDataFacilitiesA OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..60))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The X.25 facilities and Call User Data which the SPS uses on
outgoing calls. AutoCall only.
Up to 60 Hexa-Decimal digits.
Each pair of digits represents a BYTE.
BYTE-0 BYTE-1 BYTE-2 ... BYTE-29 (30 Bytes maximum)
BYTE-0 for X.25 Facilities. BYTE-1 to BYTE-29 for Call User Data.
Facilities (BYTE-0) format: PW (Hexa-Decimal), where:
X.25 L3 Packet Size Negotiation : [P=1 YES] [P=0 NO].
X.25 L3 Packet Window Negotiation : [W=1 YES] [W=0 NO].
Legal Values for Facilities BYTE-0 : 10, 01, 11, 00 (Hex).
ATTENTION: a. Total number of digits in this field must be EVEN.
b. To clear this field, enter blanks or 00."
::= {pktSwchSnaPUX25QllcEntryA 12}
pktSwchSnaPUX25QllcStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchSnaPUX25QllcStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Shows link statistics for PUs running on a QLLC link "
::= { pktSwchSna 10 }
pktSwchSnaPUX25QllcStatEntry OBJECT-TYPE
SYNTAX PktSwchSnaPUX25QllcStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Shows link statistics for PUs running on a QLLC link "
INDEX {pktSwchSnaPUX25QllcStatNumber , pktSwchSnaPUX25QllcStatSide}
::= { pktSwchSnaPUX25QllcStatTable 1 }
PktSwchSnaPUX25QllcStatEntry ::= SEQUENCE {
pktSwchSnaPUX25QllcStatNumber
Integer32,
pktSwchSnaPUX25QllcStatSide
INTEGER,
pktSwchSnaPUX25QllcStatlink
Integer32,
pktSwchSnaPUX25QllcStatDataPacketsIn
Counter32,
pktSwchSnaPUX25QllcStatDataPacketsOut
Counter32,
pktSwchSnaPUX25QllcStatQSMPacketsIn
Counter32,
pktSwchSnaPUX25QllcStatQSMPacketsOut
Counter32,
pktSwchSnaPUX25QllcStatQDMPacketsIn
Counter32,
pktSwchSnaPUX25QllcStatQDMPacketsOut
Counter32,
pktSwchSnaPUX25QllcStatXIDPacketsIn
Counter32,
pktSwchSnaPUX25QllcStatXIDPacketsOut
Counter32,
pktSwchSnaPUX25QllcStatQDISCPacketsIn
Counter32,
pktSwchSnaPUX25QllcStatQDISCPacketsOut
Counter32,
pktSwchSnaPUX25QllcStatCallPacketsIn
Counter32,
pktSwchSnaPUX25QllcStatCallPacketsOut
Counter32,
pktSwchSnaPUX25QllcStatClearPacketsIn
Counter32,
pktSwchSnaPUX25QllcStatClearPacketsOut
Counter32,
pktSwchSnaPUX25QllcStatCallAcceptsIn
Counter32,
pktSwchSnaPUX25QllcStatCallAcceptsOut
Counter32,
pktSwchSnaPUX25QllcStatUpperState
INTEGER,
pktSwchSnaPUX25QllcStatLowerState
INTEGER,
pktSwchSnaPUX25QllcStatNRMStatus
INTEGER,
pktSwchSnaPUX25QllcStatFlowCtlStatus
INTEGER
}
pktSwchSnaPUX25QllcStatNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter defines an identifier associated with the PU Entry
X25\QLLC side, which is unique within the SPS"
::= {pktSwchSnaPUX25QllcStatEntry 1}
pktSwchSnaPUX25QllcStatSide OBJECT-TYPE
SYNTAX INTEGER {
sideA(1),
sideB(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is there side A or B of the PU connection "
::= {pktSwchSnaPUX25QllcStatEntry 2}
pktSwchSnaPUX25QllcStatlink OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Link on which the Qllc conversation is conducted. If there is
no conversation the variable will be 0."
::= {pktSwchSnaPUX25QllcStatEntry 3}
pktSwchSnaPUX25QllcStatDataPacketsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUX25QllcStatEntry 4 }
pktSwchSnaPUX25QllcStatDataPacketsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUX25QllcStatEntry 5 }
pktSwchSnaPUX25QllcStatQSMPacketsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUX25QllcStatEntry 6 }
pktSwchSnaPUX25QllcStatQSMPacketsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUX25QllcStatEntry 7 }
pktSwchSnaPUX25QllcStatQDMPacketsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUX25QllcStatEntry 8 }
pktSwchSnaPUX25QllcStatQDMPacketsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUX25QllcStatEntry 9 }
pktSwchSnaPUX25QllcStatXIDPacketsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUX25QllcStatEntry 10 }
pktSwchSnaPUX25QllcStatXIDPacketsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUX25QllcStatEntry 11 }
pktSwchSnaPUX25QllcStatQDISCPacketsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUX25QllcStatEntry 12 }
pktSwchSnaPUX25QllcStatQDISCPacketsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUX25QllcStatEntry 13 }
pktSwchSnaPUX25QllcStatCallPacketsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUX25QllcStatEntry 14 }
pktSwchSnaPUX25QllcStatCallPacketsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUX25QllcStatEntry 15 }
pktSwchSnaPUX25QllcStatClearPacketsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUX25QllcStatEntry 16 }
pktSwchSnaPUX25QllcStatClearPacketsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUX25QllcStatEntry 17 }
pktSwchSnaPUX25QllcStatCallAcceptsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUX25QllcStatEntry 18 }
pktSwchSnaPUX25QllcStatCallAcceptsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPUX25QllcStatEntry 19 }
pktSwchSnaPUX25QllcStatUpperState OBJECT-TYPE
SYNTAX INTEGER {
unbound(1),
bindPending(2),
unbindPend(3),
idle(4),
unattached(5),
attachPend(6),
detachPend(7),
udqosPending(8),
outconPend(9),
inconPending(10),
connResPend(11),
dataxfer(12),
userResetPend(13),
provRstPend(14),
rstResPend(15),
discon8Pend(16),
discon9Pend(17),
discon11Pend(18),
discon12Pend(19),
discon13Pend(20),
subsBindPnd(21),
noChange(22)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The internal DLPI state of the connection."
::= { pktSwchSnaPUX25QllcStatEntry 20 }
pktSwchSnaPUX25QllcStatLowerState OBJECT-TYPE
SYNTAX INTEGER {
linkClosed(1),
disconnected(2),
linkOpening(3),
disconnecting(4),
frmrSent(5),
linkOpened(6),
localBusy(7),
rejection(8),
checkpointing(9),
cpLocalBusy(10),
cpRejection(11),
resetting(12),
remoteBusy(13),
lBusyRBusy(14),
rejLBusy(15),
rejRBusy(16),
cpRejLBusy(17),
cpClearing(18),
cpRejClr(19),
rejLbusyRbusy(20),
frmrReceived(21),
programError(22),
noChange(23)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The internal QLLC state of the connection."
::= { pktSwchSnaPUX25QllcStatEntry 21 }
pktSwchSnaPUX25QllcStatNRMStatus OBJECT-TYPE
SYNTAX INTEGER {sync(1),notSync(2)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates if the link is in Normal Response Mode or not."
::= { pktSwchSnaPUX25QllcStatEntry 22 }
pktSwchSnaPUX25QllcStatFlowCtlStatus OBJECT-TYPE
SYNTAX INTEGER {noRNR(1),txFlow(2), rxFlow(3), rxAndTx(4)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the flow control status of the PU interface."
::= { pktSwchSnaPUX25QllcStatEntry 23 }
pktSwchSnaPULlc2FrTableS OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchSnaPULlc2FrEntryS
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines LLC2/Frame Relay/RFC1490 Protocol Interface of SPS SNA PU entity. "
::= { pktSwchSna 11 }
pktSwchSnaPULlc2FrEntryS OBJECT-TYPE
SYNTAX PktSwchSnaPULlc2FrEntryS
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines parameters for PU LLC2 Protocol Interface over Frame Relay Protocol using RFC 1490."
INDEX {pktSwchSnaPULlc2FrNumberS , pktSwchSnaPULlc2FrSideS}
::= { pktSwchSnaPULlc2FrTableS 1 }
PktSwchSnaPULlc2FrEntryS ::= SEQUENCE {
pktSwchSnaPULlc2FrNumberS
Integer32,
pktSwchSnaPULlc2FrSideS
INTEGER,
pktSwchSnaPULlc2FrEncapsTypeS
INTEGER,
pktSwchSnaPULlc2FrDestMACS
OCTET STRING,
pktSwchSnaPULlc2FrSrcSAPS
OCTET STRING,
pktSwchSnaPULlc2FrDestSAPS
OCTET STRING,
pktSwchSnaPULlc2FrXIDIdBlkS
OCTET STRING,
pktSwchSnaPULlc2FrXIDIdNumS
OCTET STRING,
pktSwchSnaPULlc2FrMaxPiuSizeS
Integer32,
pktSwchSnaPULlc2FrTxWindowS
Integer32,
pktSwchSnaPULlc2FrLinkS
Integer32,
pktSwchSnaPULlc2FrDLCIS
Integer32,
pktSwchSnaPULlc2FrXIDInitiationS
INTEGER,
pktSwchSnaPULlc2FrN2CountS
Integer32,
pktSwchSnaPULlc2FrT1TimerS
Integer32,
pktSwchSnaPULlc2FrTiTimerS
Integer32,
pktSwchSnaPULlc2FrEntryStatusS
INTEGER
}
pktSwchSnaPULlc2FrNumberS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique Identifier for this PU. The value in this field is used as a common Key in both this table and the Main PU table. "
::= {pktSwchSnaPULlc2FrEntryS 1 }
pktSwchSnaPULlc2FrSideS OBJECT-TYPE
SYNTAX INTEGER {
sideA(1),
sideB(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates for each side (SIDE-A and SIDE-B) if the Protocol Interface for that side has been defined or not. "
::= {pktSwchSnaPULlc2FrEntryS 2}
pktSwchSnaPULlc2FrEncapsTypeS OBJECT-TYPE
SYNTAX INTEGER {ban(1),bnn(2),tren(3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates if the LLC2/RFC1490 Protocol Interface uses the BNN, BAN
or TREN method of Frame Encapsulation."
::= {pktSwchSnaPULlc2FrEntryS 3}
pktSwchSnaPULlc2FrDestMACS OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The LLC2 Destination MAC Address."
::= {pktSwchSnaPULlc2FrEntryS 4}
pktSwchSnaPULlc2FrSrcSAPS OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The LLC2 Source SAP Address. 2 Hex digits"
::= {pktSwchSnaPULlc2FrEntryS 5}
pktSwchSnaPULlc2FrDestSAPS OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The LLC2 Destination SAP."
::= {pktSwchSnaPULlc2FrEntryS 6}
pktSwchSnaPULlc2FrXIDIdBlkS OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Part of the IBM device ID (the full ID is defined by the IDBLK and
the IDNUM). The IDBLK is required for PU with Local XID handling
or PU with End-to-End XID handling, NO Support for NON-Activation XID.
Up to 3 Hexadecimal digits, format: 0X XX."
::= {pktSwchSnaPULlc2FrEntryS 7}
pktSwchSnaPULlc2FrXIDIdNumS OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..3))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Second part of the IBM device ID (the full ID is defined by the IDBLK and
the IDNUM). The IDNUM is required for PU with Local XID handling
or PU with End-to-End XID handling, NO Support for NON-Activation XID.
Up to 5 Hexadecimal digits, format: 0X XX XX."
::= {pktSwchSnaPULlc2FrEntryS 8}
pktSwchSnaPULlc2FrMaxPiuSizeS OBJECT-TYPE
SYNTAX Integer32 (137..7642)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum Path Information Size"
::= { pktSwchSnaPULlc2FrEntryS 9}
pktSwchSnaPULlc2FrTxWindowS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The LLC2 Link Window Size."
::= {pktSwchSnaPULlc2FrEntryS 10}
pktSwchSnaPULlc2FrLinkS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SPS Frame Relay Link Number which this LLC2 Protocol Interface is associated with."
::= {pktSwchSnaPULlc2FrEntryS 11}
pktSwchSnaPULlc2FrDLCIS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SPS Frame Relay DLCI Number which this LLC2 Protocol Interface is associated with."
::= {pktSwchSnaPULlc2FrEntryS 12}
pktSwchSnaPULlc2FrXIDInitiationS OBJECT-TYPE
SYNTAX INTEGER{
notInitiate(1),
initiate(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is not applicable for PU with Local XID handling.
Legal values:
1 - Do not initiate an XID message.
2 - Initiate an XID message to LLC2."
::= { pktSwchSnaPULlc2FrEntryS 13}
pktSwchSnaPULlc2FrN2CountS OBJECT-TYPE
SYNTAX Integer32 (1..99999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"N2 Count"
::= { pktSwchSnaPULlc2FrEntryS 14}
pktSwchSnaPULlc2FrT1TimerS OBJECT-TYPE
SYNTAX Integer32 (1..99999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"T1 Timer in 1/10 of a second."
::= { pktSwchSnaPULlc2FrEntryS 15}
pktSwchSnaPULlc2FrTiTimerS OBJECT-TYPE
SYNTAX Integer32 (1..99999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TI Timer in seconds"
::= { pktSwchSnaPULlc2FrEntryS 16}
pktSwchSnaPULlc2FrEntryStatusS OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
underCreation(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this PU Llc2 table entry.
In order to save this entry, set status to valid.
An underCreation value is set by the Agent when this entry is updated."
::= {pktSwchSnaPULlc2FrEntryS 17}
pktSwchSnaPULlc2FrTableA OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchSnaPULlc2FrEntryA
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines links for PUs running on an LLC2 link "
::= { pktSwchSna 12 }
pktSwchSnaPULlc2FrEntryA OBJECT-TYPE
SYNTAX PktSwchSnaPULlc2FrEntryA
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines parameters for PU LLC2 Protocol Interface over Frame Relay Protocol using RFC 1490."
INDEX {pktSwchSnaPULlc2FrNumberA , pktSwchSnaPULlc2FrSideA}
::= { pktSwchSnaPULlc2FrTableA 1 }
PktSwchSnaPULlc2FrEntryA ::= SEQUENCE {
pktSwchSnaPULlc2FrNumberA
Integer32,
pktSwchSnaPULlc2FrSideA
INTEGER,
pktSwchSnaPULlc2FrEncapsTypeA
INTEGER,
pktSwchSnaPULlc2FrDestMACA
OCTET STRING,
pktSwchSnaPULlc2FrSrcSAPA
OCTET STRING,
pktSwchSnaPULlc2FrDestSAPA
OCTET STRING,
pktSwchSnaPULlc2FrXIDIdBlkA
OCTET STRING,
pktSwchSnaPULlc2FrXIDIdNumA
OCTET STRING,
pktSwchSnaPULlc2FrMaxPiuSizeA
Integer32,
pktSwchSnaPULlc2FrTxWindowA
Integer32,
pktSwchSnaPULlc2FrLinkA
Integer32,
pktSwchSnaPULlc2FrDLCIA
Integer32,
pktSwchSnaPULlc2FrXIDInitiationA
INTEGER,
pktSwchSnaPULlc2FrN2CountA
Integer32,
pktSwchSnaPULlc2FrT1TimerA
Integer32,
pktSwchSnaPULlc2FrTiTimerA
Integer32
}
pktSwchSnaPULlc2FrNumberA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique Identifier for this PU. The value in this field is used as a common Key in both this table and the Main PU table. "
::= {pktSwchSnaPULlc2FrEntryA 1 }
pktSwchSnaPULlc2FrSideA OBJECT-TYPE
SYNTAX INTEGER {
sideA(1),
sideB(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates for each side (SIDE-A and SIDE-B) if the Protocol Interface for that side has been defined or not. "
::= {pktSwchSnaPULlc2FrEntryA 2}
pktSwchSnaPULlc2FrEncapsTypeA OBJECT-TYPE
SYNTAX INTEGER {ban(1),bnn(2),tren(3)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if the LLC2/RFC1490 Protocol Interface uses the BNN, BAN
or TREN method of Frame Encapsulation."
::= {pktSwchSnaPULlc2FrEntryA 3}
pktSwchSnaPULlc2FrDestMACA OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The LLC2 Destination MAC Address."
::= {pktSwchSnaPULlc2FrEntryA 4}
pktSwchSnaPULlc2FrSrcSAPA OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The LLC2 Source SAP Address."
::= {pktSwchSnaPULlc2FrEntryA 5}
pktSwchSnaPULlc2FrDestSAPA OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The LLC2 Destination SAP."
::= {pktSwchSnaPULlc2FrEntryA 6}
pktSwchSnaPULlc2FrXIDIdBlkA OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..2))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Part of the IBM device ID (the full ID is defined by the IDBLK and
the IDNUM). The IDBLK is required for PU with Local XID handling
or PU with End-to-End XID handling, NO Support for NON-Activation XID.
Up to 3 Hexadecimal digits, format: 0X XX."
::= {pktSwchSnaPULlc2FrEntryA 7}
pktSwchSnaPULlc2FrXIDIdNumA OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..3))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Second part of the IBM device ID (the full ID is defined by the IDBLK and
the IDNUM). The IDNUM is required for PU with Local XID handling
or PU with End-to-End XID handling, NO Support for NON-Activation XID.
Up to 5 Hexadecimal digits, format: 0X XX XX."
::= {pktSwchSnaPULlc2FrEntryA 8}
pktSwchSnaPULlc2FrMaxPiuSizeA OBJECT-TYPE
SYNTAX Integer32 (137..7642)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum Path Information Size"
::= {pktSwchSnaPULlc2FrEntryA 9}
pktSwchSnaPULlc2FrTxWindowA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The LLC2 Link Window Size."
::= {pktSwchSnaPULlc2FrEntryA 10}
pktSwchSnaPULlc2FrLinkA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SPS Frame Relay Link Number which this LLC2 Protocol Interface is associated with."
::= {pktSwchSnaPULlc2FrEntryA 11}
pktSwchSnaPULlc2FrDLCIA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SPS Frame Relay DLCI Number which this LLC2 Protocol Interface is associated with."
::= {pktSwchSnaPULlc2FrEntryA 12}
pktSwchSnaPULlc2FrXIDInitiationA OBJECT-TYPE
SYNTAX INTEGER{
notInitiate(1),
initiate(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter is not applicable for PU with Local XID handling.
Legal values:
1 - Do not initiate an XID message.
2 - Initiate an XID message to LLC2."
::= { pktSwchSnaPULlc2FrEntryA 13}
pktSwchSnaPULlc2FrN2CountA OBJECT-TYPE
SYNTAX Integer32 (1..99999)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"N2 Count"
::= { pktSwchSnaPULlc2FrEntryA 14}
pktSwchSnaPULlc2FrT1TimerA OBJECT-TYPE
SYNTAX Integer32 (1..99999)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"T1 Timer in 1/10 of a second."
::= { pktSwchSnaPULlc2FrEntryA 15}
pktSwchSnaPULlc2FrTiTimerA OBJECT-TYPE
SYNTAX Integer32 (1..99999)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TI Timer in seconds"
::= { pktSwchSnaPULlc2FrEntryA 16}
pktSwchSnaPULlc2FrStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchSnaPULlc2FrStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Shows link statistics for PUs running on an LLC2 link "
::= { pktSwchSna 13 }
pktSwchSnaPULlc2FrStatEntry OBJECT-TYPE
SYNTAX PktSwchSnaPULlc2FrStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Shows statistics for PU LLC2 Protocol Interface over Frame Relay Protocol using RFC 1490."
INDEX {pktSwchSnaPULlc2FrStatNumber ,
pktSwchSnaPULlc2FrStatSide} ::= { pktSwchSnaPULlc2FrStatTable 1 }
PktSwchSnaPULlc2FrStatEntry ::= SEQUENCE {
pktSwchSnaPULlc2FrStatNumber
Integer32,
pktSwchSnaPULlc2FrStatSide
INTEGER,
pktSwchSnaPULlc2FrStatOctetsIn
Counter32,
pktSwchSnaPULlc2FrStatOctetsOut
Counter32,
pktSwchSnaPULlc2FrStatIFramesIn
Counter32,
pktSwchSnaPULlc2FrStatIFramesOut
Counter32,
pktSwchSnaPULlc2FrStatRRFramesIn
Counter32,
pktSwchSnaPULlc2FrStatRRFramesOut
Counter32,
pktSwchSnaPULlc2FrStatRNRFramesIn
Counter32,
pktSwchSnaPULlc2FrStatRNRFramesOut
Counter32,
pktSwchSnaPULlc2FrStatXIDsIn
Counter32,
pktSwchSnaPULlc2FrStatXIDsOut
Counter32,
pktSwchSnaPULlc2FrStatTESTsIn
Counter32,
pktSwchSnaPULlc2FrStatTESTsOut
Counter32,
pktSwchSnaPULlc2FrStatREJsIn
Counter32,
pktSwchSnaPULlc2FrStatREJsOut
Counter32,
pktSwchSnaPULlc2FrStatFRMRsIn
Counter32,
pktSwchSnaPULlc2FrStatFRMRsOut
Counter32,
pktSwchSnaPULlc2FrStatDISCsIn
Counter32,
pktSwchSnaPULlc2FrStatDISCsOut
Counter32,
pktSwchSnaPULlc2FrStatUAsIn
Counter32,
pktSwchSnaPULlc2FrStatUAsOut
Counter32,
pktSwchSnaPULlc2FrStatDMsIn
Counter32,
pktSwchSnaPULlc2FrStatDMsOut
Counter32,
pktSwchSnaPULlc2FrStatSABMEsIn
Counter32,
pktSwchSnaPULlc2FrStatSABMEsOut
Counter32,
pktSwchSnaPULlc2FrStatRetransmitsIn
Counter32,
pktSwchSnaPULlc2FrStatRetransmitsOut
Counter32,
pktSwchSnaPULlc2FrStatUpperState
INTEGER,
pktSwchSnaPULlc2FrStatLowerState
INTEGER,
pktSwchSnaPULlc2FrStatNRMStatus
INTEGER,
pktSwchSnaPULlc2FrStatFlowCtlStatus
INTEGER
}
pktSwchSnaPULlc2FrStatNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique Identifier for this PU. The value in this field is used as a common Key in both this table and the Main PU table. "
::= {pktSwchSnaPULlc2FrStatEntry 1 }
pktSwchSnaPULlc2FrStatSide OBJECT-TYPE
SYNTAX INTEGER {
sideA(1),
sideB(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates for each side (SIDE-A and SIDE-B) if the Protocol Interface for that side has been defined or not. "
::= {pktSwchSnaPULlc2FrStatEntry 2}
pktSwchSnaPULlc2FrStatOctetsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 3}
pktSwchSnaPULlc2FrStatOctetsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 4}
pktSwchSnaPULlc2FrStatIFramesIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 5}
pktSwchSnaPULlc2FrStatIFramesOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 6}
pktSwchSnaPULlc2FrStatRRFramesIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 7}
pktSwchSnaPULlc2FrStatRRFramesOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 8}
pktSwchSnaPULlc2FrStatRNRFramesIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 9}
pktSwchSnaPULlc2FrStatRNRFramesOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 10}
pktSwchSnaPULlc2FrStatXIDsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 11}
pktSwchSnaPULlc2FrStatXIDsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 12}
pktSwchSnaPULlc2FrStatTESTsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 13}
pktSwchSnaPULlc2FrStatTESTsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 14}
pktSwchSnaPULlc2FrStatREJsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 15}
pktSwchSnaPULlc2FrStatREJsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 16}
pktSwchSnaPULlc2FrStatFRMRsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 17}
pktSwchSnaPULlc2FrStatFRMRsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 18}
pktSwchSnaPULlc2FrStatDISCsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 19}
pktSwchSnaPULlc2FrStatDISCsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 20}
pktSwchSnaPULlc2FrStatUAsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 21}
pktSwchSnaPULlc2FrStatUAsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 22}
pktSwchSnaPULlc2FrStatDMsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 23}
pktSwchSnaPULlc2FrStatDMsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 24}
pktSwchSnaPULlc2FrStatSABMEsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 25}
pktSwchSnaPULlc2FrStatSABMEsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 26}
pktSwchSnaPULlc2FrStatRetransmitsIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 27}
pktSwchSnaPULlc2FrStatRetransmitsOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { pktSwchSnaPULlc2FrStatEntry 28}
pktSwchSnaPULlc2FrStatUpperState OBJECT-TYPE
SYNTAX INTEGER {
unbound(1),
bindPending(2),
unbindPend(3),
idle(4),
unattached(5),
attachPend(6),
detachPend(7),
udqosPending(8),
outconPend(9),
inconPending(10),
connResPend(11),
dataxfer(12),
userResetPend(13),
provRstPend(14),
rstResPend(15),
discon8Pend(16),
discon9Pend(17),
discon11Pend(18),
discon12Pend(19),
discon13Pend(20),
subsBindPend(21),
noChange(22)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The internal DLPI state of the connection."
::= { pktSwchSnaPULlc2FrStatEntry 29}
pktSwchSnaPULlc2FrStatLowerState OBJECT-TYPE
SYNTAX INTEGER {
linkClosed(1),
disconnected(2),
linkOpening(3),
disconnecting(4),
frmrSent(5),
linkOpened(6),
localBusy(7),
rejection(8),
checkpointing(9),
cpLocalBusy(10),
cpRejection(11),
resetting(12),
remoteBusy(13),
lBusyRBusy(14),
rejLBusy(15),
rejRBusy(16),
cpRejLBusy(17),
cpClearing(18),
cpRejClr(19),
rejLbusyRbusy(20),
frmrReceived(21),
programError(22),
noChange(23)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The internal Llc2Fr state of the connection."
::= { pktSwchSnaPULlc2FrStatEntry 30}
pktSwchSnaPULlc2FrStatNRMStatus OBJECT-TYPE
SYNTAX INTEGER {sync(1),notSync(2)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates if the link is in Normal Response Mode or not."
::= { pktSwchSnaPULlc2FrStatEntry 31}
pktSwchSnaPULlc2FrStatFlowCtlStatus OBJECT-TYPE
SYNTAX INTEGER {noRNR(1),txFlow(2), rxFlow(3), rxAndTx(4)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the flow control status of the PU interface."
::= { pktSwchSnaPULlc2FrStatEntry 32}
pktSwchSnaGlobal OBJECT IDENTIFIER ::= { pktSwchSna 14 }
pktSwchSnaGlobalSrcMacAddrS OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"LLC2 source MAC address used for all LLC2\RFC1490 protocol interfaces,
Scratch variable. Format: XX XX XX XX XX XX"
::= {pktSwchSnaGlobal 1}
pktSwchSnaGlobalSrcMacAddrA OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LLC2 source MAC address used for all LLC2\RFC1490 protocol interfaces,
Active variable. Format: XX XX XX XX XX XX"
::= {pktSwchSnaGlobal 2}
pktSwchSnaGlobalDefFrLlc2LinkS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The FR Link to where a mac frame will be routed when the destination
MAC address of the frame does not match the SPS source mac address."
::= {pktSwchSnaGlobal 3}
pktSwchSnaGlobalDefFrLlc2LinkA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The FR Link to where a mac frame will be routed when the destination
MAC address of the frame does not match the SPS source mac address."
::= {pktSwchSnaGlobal 4}
pktSwchSnaGlobalDefFrLlc2DlciS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The FR DLCI to where a mac frame will be routed when the destination
MAC address of the frame does not match the SPS source mac address.
DLCI range is 16..991."
::= {pktSwchSnaGlobal 5}
pktSwchSnaGlobalDefFrLlc2DlciA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The FR DLCI to where a mac frame will be routed when the destination
MAC address of the frame does not match the SPS source mac address.
DLCI range is 16..991."
::= {pktSwchSnaGlobal 6}
pktSwchSnaGlobalMaxPus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of PUs that can be defined on this device. "
::= {pktSwchSnaGlobal 7}
pktSwchSnaGlobalStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
underCreation(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this SNA Global entry.
Used for saving the mac address, llc2 port, and dlci. "
::= {pktSwchSnaGlobal 8}
pktSwchEthernet OBJECT IDENTIFIER ::= { radPS 12}
pktSwchEthernetLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchEthernetLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Ethernet link table defines the parameters in the PS
Ethernet links."
::= { pktSwchEthernet 1 }
pktSwchEthernetLinkEntry OBJECT-TYPE
SYNTAX PktSwchEthernetLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Ethernet Link Entry defines the contents of each link in the
Ethernet Link Table."
INDEX {ifIndex }
::= { pktSwchEthernetLinkTable 1 }
PktSwchEthernetLinkEntry ::= SEQUENCE {
pktSwchEthernetLinkOperationMode
INTEGER,
pktSwchEthernetLinkUserDefMacAddr
OCTET STRING,
pktSwchEthernetLinkPointToPointDest
DisplayString,
pktSwchEthernetLinkTotalFramesIn
Counter32,
pktSwchEthernetLinkTotalFramesOut
Counter32,
pktSwchEthernetLinkIpFramesIn
Counter32,
pktSwchEthernetLinkIpFramesOut
Counter32,
pktSwchEthernetLinkLlc2FramesIn
Counter32,
pktSwchEthernetLinkLlc2FramesOut
Counter32,
pktSwchEthernetLinkBridgFramesIn
Counter32,
pktSwchEthernetLinkBridgFramesOut
Counter32,
pktSwchEthernetLinkDiscardedByFilter
Counter32
}
pktSwchEthernetLinkOperationMode OBJECT-TYPE
SYNTAX INTEGER{
bridging (3),
ip (4),
ip-and-bridging (7),
llc (8),
llc-and-bridging (11),
ip-and-llc (12),
all (15),
none (255) -- disabled
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter shows the frame handling mode on this link.
When IP mode is defined, the IP frames received on this link
are handled and routed by the IP module in the PS.
If IP mode is disabled, the IP frames will not be handled by the
IP module and will be handled as bridged data.
When Bridging mode is enabled, the PS will perform bridging from
this link according to the bridging configuration. If disabled,
bridge data will be ignored.
When LLC is enabled, frames received on this link are handled by
the LLC module in the PS. If disabled, the LLC frames will be
treated as bridged data.
Any combination of bridging, ip and LLC is allowed. If both IP
and LLC are enabled, LLC frames will be handled by the LLC module,
IP frames will be handled by the IP module, and all the other frames
will treated as bridged data. If the bridge mode is disabled, the
other frames will be discarded."
::= { pktSwchEthernetLinkEntry 1 }
pktSwchEthernetLinkUserDefMacAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter allows the user to define a different MAC address
for this link other than the device MAC address.
Possible values:
6 sets of 2 Hexadecimal digits with
spaces between them (XX XX XX XX XX XX) "
::= { pktSwchEthernetLinkEntry 2 }
pktSwchEthernetLinkPointToPointDest OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination of the frames which are received on this link.
Possible values:
X.25 PVC: Port:LCN
X.25 SVC: X.25 Addr or 'cid' followed by a predefined Call ID
number.
Frame Relay: Port:DLCI
No Destination: None
If no destination, frames will be forwarded according to the
filter table in 1st priority. If no filter match, the frames will be
forwarded according to dynamic learning.
Default value: None"
::={ pktSwchEthernetLinkEntry 3 }
pktSwchEthernetLinkTotalFramesIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of frames which were received on this link."
::={ pktSwchEthernetLinkEntry 4 }
pktSwchEthernetLinkTotalFramesOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of frames which were transmitted from this link."
::={ pktSwchEthernetLinkEntry 5 }
pktSwchEthernetLinkIpFramesIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of IP frames which were received on this link."
::={ pktSwchEthernetLinkEntry 6 }
pktSwchEthernetLinkIpFramesOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of IP frames which were transmitted from this link."
::={ pktSwchEthernetLinkEntry 7 }
pktSwchEthernetLinkLlc2FramesIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of LLC2 frames which were received on this link."
::={ pktSwchEthernetLinkEntry 8 }
pktSwchEthernetLinkLlc2FramesOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of LLC2 frames which were transmitted from this link."
::={ pktSwchEthernetLinkEntry 9 }
pktSwchEthernetLinkBridgFramesIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Bridged frames which were received on this link."
::={ pktSwchEthernetLinkEntry 10 }
pktSwchEthernetLinkBridgFramesOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Bridged frames which were transmitted from this link."
::={ pktSwchEthernetLinkEntry 11 }
pktSwchEthernetLinkDiscardedByFilter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Bridged frames which were received on this link."
::={ pktSwchEthernetLinkEntry 12 }
pktSwchEthernetFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchEthernetFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Ethernet filter table defines the frame filtering and
routing through the PS Ethernet links."
::= { pktSwchEthernet 2 }
pktSwchEthernetFilterEntry OBJECT-TYPE
SYNTAX PktSwchEthernetFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Ethernet Filter Entry defines the filtering on each Ethernet
link. The filter entry is operational only if Bridging Handling
is enabled and there is no point to point destination configured
for this link. If there is a point to point destination configured,
the frames will be directed to this destination."
INDEX {ifIndex, pktSwchEthernetFilterId}
::= { pktSwchEthernetFilterTable 1 }
PktSwchEthernetFilterEntry ::= SEQUENCE {
pktSwchEthernetFilterId
Integer32,
pktSwchEthernetFilterMacAddr
OCTET STRING,
pktSwchEthernetFilterProtType
INTEGER,
pktSwchEthernetFilterDest
DisplayString,
pktSwchEthernetFilterStatus
INTEGER
}
pktSwchEthernetFilterId OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identification Number of an entry in the filter table.
The ID together with the ifindex define an entry."
::= { pktSwchEthernetFilterEntry 1 }
pktSwchEthernetFilterMacAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines the MAC address in the current entry
of the filter table.
The MAC address in the filter table is compared with the MAC
address in the received frame. If the MAC address and protocol
type of the frame are equal to the values in the filter table,
the frame will be directed to the destination address specified
in the filter table.
Possible values:
MAC Address : 6 sets of 2 Hexadecimal digits with
spaces between them (XX XX XX XX XX XX)
Broadcasting: FF FF FF FF FF FF
Don't Care : 00 00 00 00 00 00
For Broadcasting:
If a broadcasting entry contains a destination, the frame will
not be broadcasted. It will be directed to the destination in this
entry.
For Don't care:
The MAC address in the frame and in the filter table are not compared.
The frames will be directed to the destination specified in the
filter table if there is a match between the protocol types in the
frame and in the filter table.
Default value: 00 00 00 00 00 00 "
::= { pktSwchEthernetFilterEntry 2 }
pktSwchEthernetFilterProtType OBJECT-TYPE
SYNTAX INTEGER{
llc (256),
ip (2048),
arp (2054),
appleTalk (32923),
dontCare (65535)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The protocol type which is compared with the protocol type
in the received frame. Each protocol in the IP frame is assigned
16 bits (see RFC1700.txt on the assignment of protocol parameters
for the Internet protocol suite.).
If 65535 is entered for the protocol, it means Don't Care.
If there is a match between this protocol and the protocol in
the received frame and a match in the MAC addresses, the frame
will be directed to the destination specified in this table.
Default value: dontCare (65535)."
::= { pktSwchEthernetFilterEntry 3}
pktSwchEthernetFilterDest OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination of the frames which match this current entry.
The match is in the MAC address and protocol.
Possible values:
X.25 PVC: Port:LCN
X.25 SVC: X.25 Addr or 'cid' followed by a predefined Call ID number
Frame Relay: Port:DLCI
No Destination: None
If No Destination, the frames will be discarded.
Default value: None ."
::={ pktSwchEthernetFilterEntry 4}
pktSwchEthernetFilterStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this filter table entry.
valid - This entry was saved.
createRequest - Request to create a new entry.
underCreation - For a new/updated entry.
invalid - Entry is deleted."
::= {pktSwchEthernetFilterEntry 5}
pktSwchEthernetBridging OBJECT IDENTIFIER ::= { pktSwchEthernet 3 }
pktSwchEthernetBridgingWanToWan OBJECT-TYPE
SYNTAX INTEGER{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable Ethernet Bridging, WAN to WAN."
::= {pktSwchEthernetBridging 1}
pktSwchEthernetBridgingTimer OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Timer used for WAN to WAN communication in order to prevent broadcast
frames looping forever between devices. When the timer expires,
the frames are discarded.
Possible values:
0 - No timer is used.
1..255 - Timer value in units of 100 mili sec."
::= {pktSwchEthernetBridging 2}
pktSwchEthernetBridgingStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
underCreation(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of the Ethernet Bridging Parameters.
valid - This table was saved.
underCreation - The table was updated and not yet saved."
::= {pktSwchEthernetBridging 3}
pktSwchEthernetBroadcastDestTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchEthernetBroadcastDestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Ethernet Broadcast Destination table defines all the Bridging
destinations of the PS. Each Broadcasted frame will be
broadcasted to all these destinations."
::= { pktSwchEthernet 4 }
pktSwchEthernetBroadcastDestEntry OBJECT-TYPE
SYNTAX PktSwchEthernetBroadcastDestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Ethernet Broadcast Entry defines destinations for Ethernet
bridge data."
INDEX {pktSwchEthernetBroadcastDestProtocol,
pktSwchEthernetBroadcastDestId}
::= { pktSwchEthernetBroadcastDestTable 1 }
PktSwchEthernetBroadcastDestEntry ::= SEQUENCE {
pktSwchEthernetBroadcastDestProtocol
INTEGER,
pktSwchEthernetBroadcastDestId
Integer32,
pktSwchEthernetBroadcastDestDestination
DisplayString,
pktSwchEthernetBroadcastDestStatus
INTEGER
}
pktSwchEthernetBroadcastDestProtocol OBJECT-TYPE
SYNTAX INTEGER{
x25 (2),
frameRelay (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The protocol of the Broadcasted frames."
::= { pktSwchEthernetBroadcastDestEntry 1 }
pktSwchEthernetBroadcastDestId OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identification Number of an entry in the Ethernet Broadcast
Destination table."
::= { pktSwchEthernetBroadcastDestEntry 2 }
pktSwchEthernetBroadcastDestDestination OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination for the Ethernet frames.
Possible values for X25:
X.25 PVC: Port:LCN
X.25 SVC: X.25 Addr or 'cid' followed by a predefined Call ID number
Possible values for fr:
Frame Relay: Port:DLCI
No Destination: None"
::={ pktSwchEthernetBroadcastDestEntry 3}
pktSwchEthernetBroadcastDestStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this Ethernet Destination table entry.
valid - This entry was saved.
createRequest - Request to create a new entry.
underCreation - For a new/updated entry.
invalid - Entry is deleted."
::= {pktSwchEthernetBroadcastDestEntry 4}
pktSwchIp OBJECT IDENTIFIER ::= { radPS 13}
pktSwchIpGlobal OBJECT IDENTIFIER ::= { pktSwchIp 1 }
pktSwchIpGlobalMaxHopCount OBJECT-TYPE
SYNTAX Integer32 (5..65000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum no. of hops the device will support.
The default value is 15. Legal values: 5 to 65000."
::= {pktSwchIpGlobal 1}
pktSwchIpIntervalBetweenUpdates OBJECT-TYPE
SYNTAX Integer32 (30..2550)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time in seconds from one update of the device's dynamic routing
table to the next update. The time is in steps of 10 seconds.
Default value: 30
Legal values: 30,40,50 ... 2550"
::= {pktSwchIpGlobal 2}
pktSwchIpGlobalStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
underCreation(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this IP Global entry.
Used for saving the IP Global parameters. "
::= {pktSwchIpGlobal 3}
pktSwchIpInterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchIpInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Ip interface table defines the Ip interfaces and their
parameters in the PS device."
::= { pktSwchIp 2 }
pktSwchIpInterfaceEntry OBJECT-TYPE
SYNTAX PktSwchIpInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The IP interface Entry defines the IP configuration parameters
for each IP interface."
INDEX {pktSwchIpInterfaceId}
::= { pktSwchIpInterfaceTable 1 }
PktSwchIpInterfaceEntry ::= SEQUENCE {
pktSwchIpInterfaceId
Integer32,
pktSwchIpInterfaceAddress
IpAddress,
pktSwchIpInterfaceAddressMask
IpAddress,
pktSwchIpInterfaceSendDefRoutMsgOnly
INTEGER,
pktSwchIpInterfaceDest
DisplayString,
pktSwchIpInterfaceInactivity
Integer32,
pktSwchIpInterfaceLinkCost
Integer32,
pktSwchIpInterfaceOptions
INTEGER,
pktSwchIpInterfaceStatus
INTEGER,
pktSwchIpInterfaceRxFrames
Counter32,
pktSwchIpInterfaceRxExpiredTtl
Counter32,
pktSwchIpInterfaceRxUnknownDest
Counter32,
pktSwchIpInterfaceTxFrames
Counter32,
pktSwchIpInterfaceTxQueueBufs
Counter32,
pktSwchIpInterfaceTxDiscarded
Counter32,
pktSwchIpInterfaceRipRxFrames
Counter32,
pktSwchIpInterfaceRipTxFrames
Counter32,
pktSwchIpInterfaceRipWaitingMsgs
Counter32
}
pktSwchIpInterfaceId OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identification Number of an entry in the IP interface table."
::= { pktSwchIpInterfaceEntry 1 }
pktSwchIpInterfaceAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the interface. Legal input: any legal IP address.
Default value: 0.0.0.0 "
::= { pktSwchIpInterfaceEntry 2 }
pktSwchIpInterfaceAddressMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP mask of the interface. Legal input: any legal IP mask:
A string of the format X.X.X.X where every X is a number in
the range 0-255.
Default value: 255.255.255.255 "
::= { pktSwchIpInterfaceEntry 3 }
pktSwchIpInterfaceSendDefRoutMsgOnly OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
enable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Some of the RIP messages are default router messages.
These messages inform who the default router is.
This MIB object allows the user to configure the device so
that it will send default router messages only.
If sendDefaultRoutMsgOnly is set to enable, the
device will not send any RIP messages except for default router
messages.
Default value: disable ."
::= { pktSwchIpInterfaceEntry 4 }
pktSwchIpInterfaceDest OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination of the packets received on this interface.
Possible values:
X.25 PVC: Port:LCN
X.25 SVC: X.25 Addr or 'cid' followed by a predefined Call ID
number.
Frame Relay: Port:DLCI
HDLC: 'H' followed by the HDLC Port Number
SLIP: 'S' followed by the SLIP Channel Number
Ethernet: 'E' followed by the Ethernet Port Number
PPP: 'P' followed by the PPP Port Number.
Bundles(for PPP)'B' followed by the PPP Bundle Number.
No destination: None
Default : None
Examples:
1. For SLIP destination which is Link no. 1, the destination
will be S100 (100 instead of 1 is for Async).
2. For SLIP destination of APS-8, channel no. 8:
S8
3. For PPP destination of APS-8, Sync Link no. 1: P1
4. For PPP destination of APS-8, Async channel on link 1: P100
Note for PPP:
PPP protocol is allowed to be applied on Sync Links (1-3)
as well as Async channels (1-24).
In the ascii terminal: If the user writes P1 for example the device
has to check which P1 it is. Is it the async channel 1 or
Link no. 1. The device does NOT ALLOW configuring PPP on both
Sync Link no. 1 and async RJ45 channel 1.
When P1 is entered by the user, the protocols on async channel 1 and sync
link 1 are checked. As only one of them is PPP, it will apply to the
only PPP chan/link."
::= { pktSwchIpInterfaceEntry 5 }
pktSwchIpInterfaceInactivity OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Inactivity time in minutes before disconnecting the X25 SVC call.
Range: 0..255. Default: 2."
::= { pktSwchIpInterfaceEntry 6 }
pktSwchIpInterfaceLinkCost OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value will be added to the value written in the
metric field of the received frame.
Range: 1..pktSwchIpGlobalMaxHopCount
Default: 1."
::= { pktSwchIpInterfaceEntry 7 }
pktSwchIpInterfaceOptions OBJECT-TYPE
SYNTAX INTEGER {
netIpAddress (2),
none (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When netIpAddress is selected the interface IP address
will not be the IP address of the interface. It will be the IP
address of the NetWork which is connected to this interface.
This option is for an interface which does not require a
unique IP address.
Default is none."
::= { pktSwchIpInterfaceEntry 8 }
pktSwchIpInterfaceStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this filter table entry.
valid - This entry was saved.
createRequest - Request to create a new entry.
underCreation - For a new/updated entry.
invalid - Entry is deleted."
::= { pktSwchIpInterfaceEntry 9 }
pktSwchIpInterfaceRxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"No. of frames which were received on this IP interface."
::= { pktSwchIpInterfaceEntry 10 }
pktSwchIpInterfaceRxExpiredTtl OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"No. of frames which were received on this IP interface
with an Expired Time to Live value."
::= { pktSwchIpInterfaceEntry 11 }
pktSwchIpInterfaceRxUnknownDest OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"No. of frames which were received on this IP interface
with an unknown IP destination. No default router is configured.
These frames will be discarded."
::= { pktSwchIpInterfaceEntry 12 }
pktSwchIpInterfaceTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"No. of frames which were Transmitted from this IP interface."
::= { pktSwchIpInterfaceEntry 13 }
pktSwchIpInterfaceTxQueueBufs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"No. of buffers which are waiting in the Trasnsmit Queue. "
::= { pktSwchIpInterfaceEntry 14 }
pktSwchIpInterfaceTxDiscarded OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"No. of frames which were ready to be transmitted but were
Discarded. The PS will discard frames if the transmit queue
is too long."
::= { pktSwchIpInterfaceEntry 15 }
pktSwchIpInterfaceRipRxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"No. of RIP frames which were received on this IP interface."
::= { pktSwchIpInterfaceEntry 16 }
pktSwchIpInterfaceRipTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"No. of RIP Frames which were transmitted from this IP interface."
::= { pktSwchIpInterfaceEntry 17 }
pktSwchIpInterfaceRipWaitingMsgs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"No. of RIP messages which are waiting to be transmitted to the
Network."
::= { pktSwchIpInterfaceEntry 18 }
pktSwchIsdn OBJECT IDENTIFIER ::= { radPS 14}
-- Packet Switching devices with Integrated Services Digital Network.
pktSwchIsdnGlobal OBJECT IDENTIFIER ::= { pktSwchIsdn 1 }
-- ISDN Global Parameters
pktSwchIsdnGlobalCallRetries OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of times the call request is repeated after failure.
Possible values:
0 - Disable retry mechanism
1-255 - Number of retries
default value: 0"
::= {pktSwchIsdnGlobal 1}
pktSwchIsdnGlobalCallRetryDelay OBJECT-TYPE
SYNTAX Integer32 (5..250)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time interval between retries (in seconds).
Possible values:
5 - 250
Default value: 15"
::= {pktSwchIsdnGlobal 2}
pktSwchIsdnGlobalCallinactivity OBJECT-TYPE
SYNTAX Integer32 (0..65000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time of inactivity in seconds, after which the call will be
disconnected. An x.25 link is considered inactive when there are
no open calls on the link. A frame relay link is considered inactive
when there is no traffic on the link.
Possible values:
0 - No disconnection on inactivity.
1 - 65000 - Time period (in seconds).
Default value: 180"
::= {pktSwchIsdnGlobal 3}
pktSwchIsdnGlobalStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
underCreation(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of the Isdn Global parameters.
Used for saving the Isdn global parameters."
::= {pktSwchIsdnGlobal 4}
pktSwchIsdnRoutTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchIsdnRoutEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Isdn Routing Table entries in the Packet Switch."
::= { pktSwchIsdn 2 }
pktSwchIsdnRoutEntry OBJECT-TYPE
SYNTAX PktSwchIsdnRoutEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Isdn Routing Entry defines the contents of each entry in the table.
The outgoing addresses are in a different table -
pktSwchIsdnRoutAddrTable. The row status in this
table will be used for both tables."
INDEX { pktSwchIsdnRoutId }
::= { pktSwchIsdnRoutTable 1 }
PktSwchIsdnRoutEntry ::= SEQUENCE {
pktSwchIsdnRoutId
Integer32,
pktSwchIsdnRoutDataBandWidth
INTEGER,
pktSwchIsdnRoutOptions
INTEGER,
pktSwchIsdnRoutStatus
INTEGER
}
pktSwchIsdnRoutId OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of this routing entry."
::= { pktSwchIsdnRoutEntry 1 }
pktSwchIsdnRoutDataBandWidth OBJECT-TYPE
SYNTAX INTEGER {
bw56Kbps(2),
bw64Kbps(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Isdn Bandwidth which will be used for the data routed via this
entry. The ISDN interface will be configured with the speed
which is selected.
Possible values:
2 - 56 Kbps.
3 - 64 Kbps.
Default value: 3 "
::= { pktSwchIsdnRoutEntry 2 }
pktSwchIsdnRoutOptions OBJECT-TYPE
SYNTAX INTEGER {
noOptions(1),
returnToMainLink(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Special Options for this routing entry.
Possible values:
1 - No special options.
2 - Return to main link. This option is used when the current link
is defined as a backup link and the main link becomes active.
Default value: 1 "
::= { pktSwchIsdnRoutEntry 3 }
pktSwchIsdnRoutStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this routing table entry + address table
(pktSwchIsdnOutAddrTable).
For creating a new entry select createRequest. A new route entry
will be created together with an out address entry. There may be
more than 1 addresses. For example, if there is 1 outgoing address
and 2 alternatives, the new address entry will have 3 indices.
For deleting an entry select invalid. The relevant address entry
should be deleted too.
For saving an entry select valid. Save should include the addresses
of the current entry in the pktSwchIsdnOutAddrTable"
::= { pktSwchIsdnRoutEntry 4 }
pktSwchIsdnOutAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchIsdnOutAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Outgoing ISDN addresses used by the ISDN routing table.
The address table contains outgoing
addresses and alternative addresses in case the connection
to the first addresses does not succeed."
::= { pktSwchIsdn 3 }
pktSwchIsdnOutAddrEntry OBJECT-TYPE
SYNTAX PktSwchIsdnOutAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Isdn Outgoing Address Entry defines the contents of each entry in
the outgoing address table.
Each entry has 2 indices:
1. RoutId is the ID in the routing table.
2. AddrId is the ID containing the Outgoing address and
sub address. "
INDEX { pktSwchIsdnOutAddrRoutId, pktSwchIsdnOutAddrId }
::= { pktSwchIsdnOutAddrTable 1 }
PktSwchIsdnOutAddrEntry ::= SEQUENCE {
pktSwchIsdnOutAddrRoutId
Integer32,
pktSwchIsdnOutAddrId
Integer32,
pktSwchIsdnOutAddr
DisplayString,
pktSwchIsdnOutSubAddr
DisplayString
}
pktSwchIsdnOutAddrRoutId OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ID in the ISDN routing table."
::= { pktSwchIsdnOutAddrEntry 1 }
pktSwchIsdnOutAddrId OBJECT-TYPE
SYNTAX Integer32 (1..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of the address + subaddress pair for each routing ID."
::= { pktSwchIsdnOutAddrEntry 2 }
pktSwchIsdnOutAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..17))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination ISDN Outgoing (Remote) address.
The data will be routed out to this address.
Possible values:
Up to 17 decimal digits.
Default value: string of length 0."
::= { pktSwchIsdnOutAddrEntry 3 }
pktSwchIsdnOutSubAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination ISDN Outgoing (Remote) sub address.
The data will be routed out to the out addrress with
this sub address.
Possible values:
Up to 6 decimal digits.
Default value: string of length 0."
::= { pktSwchIsdnOutAddrEntry 4 }
pktSwchIsdnAcceptTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchIsdnAcceptEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of Isdn addresses which will be accepted by the agent.
If there is a dial back (answer) address, the incoming call
will be disconnected and dial back will initiate. Most of
the accept list parameters are in RFC2128 in the
dialCtlPeerCfgTable. The parameters which are not in the
the standard RFC2128 and are required, are defined here
in the private PS MIB."
::= { pktSwchIsdn 4 }
pktSwchIsdnAcceptEntry OBJECT-TYPE
SYNTAX PktSwchIsdnAcceptEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Isdn Accept Entry defines the contents of each entry in the table."
INDEX { pktSwchIsdnAcceptId }
::= { pktSwchIsdnAcceptTable 1 }
PktSwchIsdnAcceptEntry ::= SEQUENCE {
pktSwchIsdnAcceptId
Integer32,
pktSwchIsdnAcceptSecondaryLink
Integer32,
pktSwchIsdnAcceptDialbkSubAddress
DisplayString,
pktSwchIsdnAcceptStatus
INTEGER
}
pktSwchIsdnAcceptId OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifier of Accept table entry."
::= { pktSwchIsdnAcceptEntry 1 }
pktSwchIsdnAcceptSecondaryLink OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A valid Isdn link number on which the call will be accepted
when the Primary link (RFC2128.dialCtlPeerCfgLowerIf)is unavailable.
Possible values:
255 - No Secondary link.
or
The complementary to the primary ISDN link number.
Complementary links are: [1;2] and [7;8].
If Primary Link Number is set to first available <0>,
the Secondary link must be set to No Secondary link <255>.
Default value is complementary to the primary link no. defined in
rfc2128.dialCtlPeerCfgLowerIf."
::= { pktSwchIsdnAcceptEntry 2 }
pktSwchIsdnAcceptDialbkSubAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Isdn sub address which will be used by the agent for dialing
back.
Possible values:
Up to 6 decimal digits.
Default value: string of length 0."
::= { pktSwchIsdnAcceptEntry 3 }
pktSwchIsdnAcceptStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this accept table entry.
For creating a new entry select createRequest,
For deleting an entry select invalid.
For saving an entry select valid."
::= { pktSwchIsdnAcceptEntry 4 }
pktSwchIsdnLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchIsdnLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of Isdn Link parameters. Most of the link parameters
are in in RFC2127. Isdn Call statistics are RFC2128.
The parameters which are not in the the standard RFCs ,
and are required, are defined here in the private PS MIB."
::= { pktSwchIsdn 5 }
pktSwchIsdnLinkEntry OBJECT-TYPE
SYNTAX PktSwchIsdnLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Isdn Link Entry defines the contents of each entry in the table."
INDEX {ifIndex }
::= { pktSwchIsdnLinkTable 1 }
PktSwchIsdnLinkEntry ::= SEQUENCE {
pktSwchIsdnLinkBchannel
INTEGER,
pktSwchIsdnCallsClrs
Counter32,
pktSwchIsdnTestCmd
INTEGER,
pktSwchIsdnTestAddr
DisplayString,
pktSwchIsdnTestSubAddr
DisplayString
}
pktSwchIsdnLinkBchannel OBJECT-TYPE
SYNTAX INTEGER {
noBchannel(1),
b1(2),
b2(3),
b1Andb2(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines which B channels are used for Leased Lines Only.
Default value: noBchannel(1)."
::= { pktSwchIsdnLinkEntry 1 }
pktSwchIsdnCallsClrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of calls on this link which were cleared since the link was
activated."
::= { pktSwchIsdnLinkEntry 2 }
pktSwchIsdnTestCmd OBJECT-TYPE
SYNTAX INTEGER {
noOp (2),
activate (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Activate/Stop an ISDN test on the current ISDN link.
In order to Activate the test, set the TestCmd to 3 (activate).
For stopping the test, set the TestCmd to 2 (noOp).
Important: In order for the test to succeed, the user must set
the pktSwchIsdnTestAddr and Subaddr to their required values before
activating the test. "
::= { pktSwchIsdnLinkEntry 3 }
pktSwchIsdnTestAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..17))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination ISDN Outgoing (Remote) address which will be
called in order to test the ISDN.
Possible values:
Up to 17 decimal digits.
Default value: string of length 0.
Important: In order for the test to succeed, the user must also set
the pktSwchIsdnTestSubAddr to the required values before
activating the test. "
::= { pktSwchIsdnLinkEntry 4 }
pktSwchIsdnTestSubAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination ISDN Outgoing (Remote) address which will be
called in order to test the ISDN.
Possible values:
Up to 6 decimal digits.
Default value: string of length 0.
Important: In order for the test to succeed, the user must also set
the pktSwchIsdnTestAddr to the required values before
activating the test. "
::= { pktSwchIsdnLinkEntry 5 }
pktSwchPpp OBJECT IDENTIFIER ::= { radPS 15}
-- Point to Point Protocol in the Packet Switching devices.
-- PPP Global Parameters:
-- All the parameters are in: RFC1472, PPP Security Secrets Table.
-- The Security Secrets table contains pairs of Identity and secrets
-- (Port User Name and Port Password).
-- The link no. which is used for the Secrets table is: 0.
-- Link no. 0 in RFC1472 means that the ID/Secret pair applies to all links.
--
-- The ROW status of rfc1472 could not be used because it has only 2 values:
-- valid and invalid. There is no option for create request as is used
-- in the Packet Switches.
-- The only parameter which was added here is the ROW status for the table.
pktSwchPppSecretsTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchPppSecretsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of PPP Secret parameters.
The parameters are defined in rfc1472 except for the ROW status
which is defined here.
In the standard, there is no create request option, so in order
to be consistent with other ROW statuses in the Packet Switches
it is defined here."
::= { pktSwchPpp 1 }
pktSwchPppSecretsEntry OBJECT-TYPE
SYNTAX PktSwchPppSecretsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PPP Secrets Entry defines the contents of each entry in the table."
INDEX {pktSwchPppSecretsPairId}
::= { pktSwchPppSecretsTable 1 }
PktSwchPppSecretsEntry ::= SEQUENCE {
pktSwchPppSecretsPairId
Integer32,
pktSwchPppSecretsStatus
INTEGER
}
pktSwchPppSecretsPairId OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the Secrets Pair."
::= { pktSwchPppSecretsEntry 1 }
pktSwchPppSecretsStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of the PPP Secrets table.
For creating a new entry select createRequest,
For deleting an entry select invalid.
For saving an entry select valid."
::= { pktSwchPppSecretsEntry 2 }
pktSwchPppChanTable OBJECT-TYPE
SYNTAX SEQUENCE OF PktSwchPppChanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of PPP Channel parameters.
The table can be used for Async as well as Sync parameters.
In case a parameter is irrelevant for Async or Sync a <not
applicable> value may be returned.
Statistics Parameters are already defined in rfc1213:
ifInUcastPkts, ifOutUcastPkts, ifInErrors, ifOutErrors"
::= { pktSwchPpp 2 }
pktSwchPppChanEntry OBJECT-TYPE
SYNTAX PktSwchPppChanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PPP Channel Entry defines the contents of each entry in the table."
INDEX {ifIndex }
::= { pktSwchPppChanTable 1 }
PktSwchPppChanEntry ::= SEQUENCE {
pktSwchPppChanSpeed
INTEGER,
pktSwchPppChanFlowCtlDuration
Integer32,
pktSwchPppChanStopBits
INTEGER,
pktSwchPppChanBitPerChar
Integer32,
pktSwchPppChanParity
INTEGER,
pktSwchPppChanNegotiationTrigger
INTEGER,
pktSwchPppChanMRU
Integer32,
pktSwchPppChanACCM
OCTET STRING,
pktSwchPppChanAuthentication
INTEGER,
pktSwchPppChanInternalClock
INTEGER,
pktSwchPppChanBundle
Integer32,
pktSwchpPppChanIsdnRoutId
Integer32,
pktSwchpPppChanLastEvent
DisplayString,
pktSwchpPppChanModemInitString
DisplayString,
pktSwchpPppChanModemDialString
DisplayString
}
pktSwchPppChanSpeed OBJECT-TYPE
SYNTAX INTEGER {
s110bps (1),
s300bps (2),
s1200bps (3),
s600bps (4),
s75bps (5),
s150bps (6),
s2400bps (12),
s4800bps (13),
s9600bps (14),
s19200bps (15),
s38400bps (19),
s57600bps (20),
s115200bps(21),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port's speed in bits per second.
For Async channels: Default value: 14 .
For Sync Links: Use not_applicable(255)
The Sync Links have an internal clock with
different values."
::= { pktSwchPppChanEntry 1 }
pktSwchPppChanFlowCtlDuration OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Hardware Flow Control Duration.
1..254 - Duration (in 50ms intervals).
when timer expires, flow control stops.
0 - No Hardware flow control.
255 - Continuous Flow Control.
Default value: 0.
For Sync Links, return 0."
::= { pktSwchPppChanEntry 2 }
pktSwchPppChanStopBits OBJECT-TYPE
SYNTAX INTEGER {
one (1),
two (2),
oneAndHalf(3),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates the number of stop bits per character.
The options are either (1) one stop bit, (2) two stop bits,
or (3) 1.5 stop bits.
For Sync Links: notApplicable(255)."
::= { pktSwchPppChanEntry 3 }
pktSwchPppChanBitPerChar OBJECT-TYPE
SYNTAX Integer32 (0..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of data bits per character supported by the ppp
link. Legal values for Async channels: 5..8 .
For Sync Links: 0"
::= { pktSwchPppChanEntry 4 }
pktSwchPppChanParity OBJECT-TYPE
SYNTAX INTEGER {
space(1),
mark(2),
even(3),
odd(4),
none(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry selects the type of parity to be checked or
generated.
The options are (1) space parity, (2) mark parity,
(3) even parity, (4) odd parity, or (255) no parity.
For Sync Links: none(255)."
::= { pktSwchPppChanEntry 5 }
pktSwchPppChanNegotiationTrigger OBJECT-TYPE
SYNTAX INTEGER {
hw-signal (1),
data-triggered (2),
hw-signal-or-data(3),
after-reset (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The trigger which is used in order to start the Negotiation.
The HW signals which are used are:
DCD (Data Carrier Detect) - issued by DCE
DSR (Data Set Ready) - issued by DCE
DTR (Data Terminal Ready) - issued by DTE
1 - Start negotiation on signal assertion.
The Peer will issue a DCD/DSR Signal if it is DCE or
DTR if it is DTE.
If the current channel/link is DCE, it will check the DTR.
If the current channel/link is DTE, it will check the DCD/DSR.
When the HW signal is issued, negotiation will begin.
2 - Data Triggered.
The current channel/link will issue a HW signal.
Negotiation will begin when data is received.
3 - Combination of option 1 and option 2.
255 - Starts negotiation after reset. Ignore HW signals.
Default Value for Async Channel: 255.
Default Value for Sync Link: 3"
::= { pktSwchPppChanEntry 6 }
pktSwchPppChanMRU OBJECT-TYPE
SYNTAX Integer32 (1500..4096)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum Receive Unit.
Size of the packet which is negotiated with the connected device.
Default value: 1500 ."
::= { pktSwchPppChanEntry 7 }
pktSwchPppChanACCM OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Async Control Character Map -
The ACCM value serves as a mask for the first 32 characters
in the ASCII table.
Control characters may cause problems when they are transferred
on the network. This can be handled by escaping them
( adding escape character to them ).
For example , when using modems in the network which can not
receive X-on and X-off characters. The ACCM is a mask which shows
which control characters will be handled with an escape sequence.
Each bit represents one character.
Possible values:
Octet string of 4 bytes: 00000000 .
A bit with value 1 will cause the character to be in an escape sequence.
0 will leave the character as it is.
Example : to use XON and XOFF as escape sequence : 000A0000
Default value: 00000000.
For Sync Links return the default."
::= { pktSwchPppChanEntry 8 }
pktSwchPppChanAuthentication OBJECT-TYPE
SYNTAX INTEGER {
no-authentication(1),
pap-or-chap (2),
chap-only (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Authentication Type.
1 - No Authentication: User side Only.
2 - Configuration of the Host side.
PAP (Password Authentication Protocol) or
CHAP (Challenge Handshake Authentication Protocol)
will be accepted by the current host.
3 - Configuration of the host side as CHAP only.
Only CHAP will be accepted by the current host.
Default value: 1 ."
::= { pktSwchPppChanEntry 9 }
pktSwchPppChanInternalClock OBJECT-TYPE
SYNTAX INTEGER {
r3000bps (1),
r4800bps (2),
r9600bps (3),
r14400bps(4),
r19200bps(5),
r38400bps(6),
r48Kbps (7),
r56Kbps (8),
r64Kbps (9),
r128Kbps (10),
r256Kbps (11),
r384Kbps (12),
r512Kbps (13),
r768Kbps (14),
r1024Kbps(15),
r1445Kbps(16),
r2048Kbps(17),
external(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The internal clock rate of the MLPPP Link.
Default value: 9.
For Async channels: return 255."
::= { pktSwchPppChanEntry 10 }
pktSwchPppChanBundle OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bundle Number.
It is possible to attach a few channels/links to a bundle.
If the User enters a non existing bundle number, the PS will
create a new bundle with this number.
The bundle number may be: 1..255
If the bundle number is 0 it means: do not attach to bundle.
Default value: 0 ."
::= { pktSwchPppChanEntry 11 }
pktSwchpPppChanIsdnRoutId OBJECT-TYPE
SYNTAX Integer32 (0..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ISDN destination. ID (1..200) in the ISDN routing table containing
the outgoing ISDN address for this channel/link.
For no destination: 0
Default value: 0 "
::= { pktSwchPppChanEntry 12 }
pktSwchpPppChanLastEvent OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status showing the last PPP event which occured on the line
described in an ascii string.
Examples:
1. Received Configuration Request.
2. Sent Protocol Reject.
3. Error: Can Not Compress Frame.
Default: 0 for no last event on this link or channel."
::= { pktSwchPppChanEntry 13 }
pktSwchpPppChanModemInitString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..29))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This string is needed by the modem in order to be initiated,
before dialing."
::= { pktSwchPppChanEntry 14 }
pktSwchpPppChanModemDialString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..29))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This string enables the modem to open a new call."
::= { pktSwchPppChanEntry 15 }
-- TRAPS for use by the PS
linkProtocolChanged NOTIFICATION-TYPE
OBJECTS { pktSwchPhyInterfaceIfIndex, pktSwchPhyInterfaceProtocolA}
STATUS current
DESCRIPTION
"Upon setting of a new protocol to a specific interface."
::= { radSysPSEvents 1 }
enrollmentPS NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Periodic trap to be sent to the list of managers."
::= { radSysPSEvents 2 }
rtsChange NOTIFICATION-TYPE
OBJECTS { pktSwchChannelNumberA }
STATUS current
DESCRIPTION
" "
::= { radSysPSEvents 3 }
ledStatusChange NOTIFICATION-TYPE
OBJECTS { agnLed }
STATUS current
DESCRIPTION
"The trap is sent when one of the Hazard LEDs has changed."
::= { radSysPSEvents 4 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\dacs.txt
--
--Title: RAD's DACS PRODUCTS MIB
--Date: 27.04.95
--By: Smadar Tauber
--File: dacs.txt
--
--Last update: 5-May-2008 by Liora Gafni
dacsMux OBJECT IDENTIFIER ::= {radWan 3}
systemDacsMux OBJECT IDENTIFIER ::= {dacsMux 1}
mdlDacsMux OBJECT IDENTIFIER ::= {dacsMux 2}
prtDacsMux OBJECT IDENTIFIER ::= {dacsMux 3}
genDacsMux OBJECT IDENTIFIER ::= {dacsMux 4}
--System level of DACS MIB
--
--Sa - data specific to a stand-alone unit
--Hub - data specific to a Hub unit
--Rest of the branches are common to both types of units.
sysSa OBJECT IDENTIFIER ::= {systemDacsMux 1}
sysHub OBJECT IDENTIFIER ::= {systemDacsMux 2}
sysStatus OBJECT IDENTIFIER ::= {systemDacsMux 3}
sysCurrentAlr OBJECT IDENTIFIER ::= {systemDacsMux 4}
sysBufferAlr OBJECT IDENTIFIER ::= {systemDacsMux 5}
sysConfig OBJECT IDENTIFIER ::= {systemDacsMux 6}
sysDbase OBJECT IDENTIFIER ::= {systemDacsMux 7}
--Stand-alone specific parameters
sysSaSwchStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the status of the switches on
the SA unit.
Each switch is represented by a bit. The status is a sum
of 2**n, according to the bits.
For SMODs products see modem's specification.
For DXC product see the following:
There are 4 switches:
bit 0 SP-PAR (LSB) '1' - Default parameters
bit 1 PSWRD '1' - Password=default
'0' - Password=user selected
bit 2 DB-INIT '1' - DB initiated with default
'0' - DB initiated with NVRAM contents
bit 3 PC-SP (MSB) '1' - Management by terminal only
'0' - Management by NMS
Example: If SP-PAR and PSWRD bits are set ('1'), the value
will be 3 (2**1 + 2**0).
When the status of the switches is unknown, the value of
this object will be 255."
::= { sysSa 1}
sysSaSwRevision OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Software revision of the
system."
::= {sysSa 2}
sysSaHwVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Hardware version of the
system."
::= {sysSa 3}
sysSaPorts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the ports that are present in the
system.
Each possible port is represented by a bit.
The value of this object is a sum of 2**n, n=number of bits.
'1' - means that the port exists
'0' - means that the port does not exist
For detailed bit assignment, see product's spec.
Bit 0 = LSB
When this object is not relevant, the value will be 0.
In some cases, this object may represent ports configuration
of the system AND its far-end unit."
::= {sysSa 4}
sysSaReadSwch OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates wether the configuration will be read from the DIP switches
on the SA (stand alone) unit.
Each switch is represented by a bit.
If the bit is 1: the configuration will be read from the HW switch position.
If the bit is 0: the configuration will be read from the SW user configuration.
The DIP switches are different in each of the RAD devices.
In the Tiny Router (starting from the LSB) the following switches exist:
Bit 0: WAN Loop
Bit 1: LAN Full Duplex (When LAN AUI connector, it is SQE)
Bit 2: PPP (When WAN 4 Wire connector, it is LONG)
Bit 3: IP Learn"
::= {sysSa 5}
sysSaBuActivePort OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
e1T1orSerial (2),
eth (3),
primary (4),
secondary (5),
third (6),
fourth (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows through which port the traffic is flowing
(the current Active Port) when the Backup mechanism exists.
When No Backup exists in the device, the value should be: notApplicable(1)."
::= {sysSa 6}
--Hub specific parameters
--Hub Cassis data
sysChas OBJECT IDENTIFIER ::= {sysHub 1}
chassTotalNoOfSlt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of physical slots in
the Hub chassis."
::= { sysChas 1 }
chassTotalNoOfIoSlt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the total number of physical IO slots
in the chassis, (not all slots must be occupied and active)."
::= { sysChas 2 }
chassTotalNoOfPsSlt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of physical Power Supply
slots in the chassis."
::= { sysChas 3 }
chassTotalNoOfClSlt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of physical Common Logic
slots in the chassis."
::= { sysChas 4 }
chassTotalNoOfMlSlt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of physical Main Link
slots in the chassis (Kmux)."
::= { sysChas 5 }
--Hub DCL parameters
sysDcl OBJECT IDENTIFIER ::= {sysHub 2}
sysDclTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysDclEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"All the entries of this table are identical (have the
same value) for all the configurations (1..255) except
the TmpCnfg.
The write operation into the Table Objects is valid only
for the TmpCnfg entry."
::= { sysDcl 1}
sysDclEntry OBJECT-TYPE
SYNTAX SysDclEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {sysDclCnfgIdx}
::= { sysDclTable 1}
SysDclEntry ::=
SEQUENCE {
sysDclCnfgIdx Integer32,
sysDclRedundancy INTEGER,
sysDclActiveCl INTEGER,
sysDclFlipDelay Integer32,
sysDclFlipUponStnClk INTEGER,
sysDclChFailThreshold Integer32,
sysDclChPriority OCTET STRING,
sysDclConfigDownloadSrc INTEGER,
sysDclSwDownloadSrc INTEGER,
sysDclRedundancyStatus BITS
}
sysDclCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg(1..255)
being accessed ; Idx of 255 relates to the TmpCnfg.
This object is identical for all the configurations (1..255).
Only the TmpCnf(255) might have a different value.
For devices that work on line with NMS (no Temp configuration in NMS),
Get and Set will be performed with index value of sysDclCnfgIdx = 1."
::= { sysDclEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
sysDclRedundancy OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" DCL redundancy desired state."
::= {sysDclEntry 2}
sysDclActiveCl OBJECT-TYPE
SYNTAX INTEGER
{
auto (1),
dclA (2),
dclB (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Active desired DCL.
When 'auto' is selected, the system automatically selects
the active DCL."
::= {sysDclEntry 3}
sysDclFlipDelay OBJECT-TYPE
SYNTAX Integer32
-- {
-- t1min (1),
-- t2min (2),
-- t3min (3),
-- t4min (4)
-- }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If one DCL flip occurred and a second one should be
performed, the time from the previous flip is checked.
If the time is shorter than the delay specified here,
the system should delay the flip operation until time reaches the specified delay.
For DXC the values are 1 minute to 4 minutes (1..4).
For Optimux-155-1 and Optimux-155-3 the values are: 0...60 Sec.
0 means No Delay."
::= {sysDclEntry 4}
sysDclFlipUponStnClk OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows user to decide (yes/no) if Agent should Flip from
one DCL card to another, when there is Station Clock Fail in
the Online DCL card."
::= {sysDclEntry 5}
sysDclChFailThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the number of failed channels that will trigger the
redundancy procedure."
::= {sysDclEntry 6}
sysDclChPriority OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Priority for all the channels in the Main Access
(Common Logic) card. Each channel is represented by 1 bit.
The order of the bits in each byte is from Right to Left (LSB Bit to MSB)
starting from BIT 0: 7 6 5 4 3 2 1 0
Channel no. 1 is represented by bit 0.
Channel no. 2 is represented by bit 1.
Channel no. n is represented by bit n-1.
The value of the bit shows the priority.
For bit value = 1, Priority = High.
For bit value = 0, Priority = Low."
::= {sysDclEntry 7}
sysDclConfigDownloadSrc OBJECT-TYPE
SYNTAX INTEGER
{
off (1),
dclA (2),
dclB (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In case of mismatch between the 2 CL card's configuration, the user can decide
which card has the suitable configuration.
The selected configuration will be downloaded from card A to card B
if the value is dclA(2) or from card B to card A if the value is dclB(3).
off(1) is used by part of the devices. In this case, after operation ends -
value should be automatically set to off(1), which is the default state."
::= {sysDclEntry 8}
sysDclSwDownloadSrc OBJECT-TYPE
SYNTAX INTEGER
{
off (1),
dclA (2),
dclB (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In case of mismatch between the 2 CL card's software, the user can decide
which card has the suitable SW.
The selected SW will be downloaded from card A to card B if the value is dclA(2)
or from card B to card A if the value is dclB(3).
off(1) is used by part of the devices. In this case, after operation ends -
value should be automatically set to off(1), which is the default state."
::= {sysDclEntry 9}
sysDclRedundancyStatus OBJECT-TYPE
SYNTAX BITS
{
cnfgMismatch (0),
swMismatch (1),
cardAAbsent (2),
cardBAbsent (3),
lossOfCommunication (4),
hwMismatch (5),
cnfgUpdate (6),
swUpdate (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bit map representing current Redundancy Status.
bit 0 - Indicates mismatch between the 2 CL cards' Configuration
bit 1 - Indicates mismatch between the 2 CL cards' Software.
bit 2 - Indicates CL card A Absence.
bit 3 - Indicates CL card B Absence.
bit 4 - Indicates Loss of Communication between the 2 CL cards.
bit 5 - Indicates mismatch between the 2 CL cards' Hardware.
bit 6 - Indicates Configuraton update is in process.
bit 7 - Indicates Software update is in process.
"
::= {sysDclEntry 10}
sysDclOnline OBJECT-TYPE
SYNTAX INTEGER
{
dclA (1),
dclB (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The active Dcl card of the agent."
::= {sysDcl 2}
sysDclCopyDbTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysDclCopyDbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table enables to copy a cofiguration from the Offline
Dcl to the Online Dcl."
::= { sysDcl 3}
sysDclCopyDbEntry OBJECT-TYPE
SYNTAX SysDclCopyDbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {sysDclCopyDbIdx}
::= { sysDclCopyDbTable 1}
SysDclCopyDbEntry ::=
SEQUENCE {
sysDclCopyDbIdx Integer32,
sysDclCopyDbCmd INTEGER
}
sysDclCopyDbIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg(1..255)
being accessed. "
::= { sysDclCopyDbEntry 1}
sysDclCopyDbCmd OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this command is sent to the agent, on(3), the Database
specified (Db Idx), will be copied from the Offline Dcl
to the Online Dcl. Afterwards the value of this object will
automatically change to off(2). "
::= { sysDclCopyDbEntry 2}
sysDclFlipCmd OBJECT-TYPE
SYNTAX INTEGER {
off (2),
flip (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the 'flip(3)' command is received by Agent, it will flip (switch)
between Offline Dcl and Online Dcl cards. Afterwards the value of
this object will automatically change to off(2)."
::= { sysDcl 4}
--General System - General Status parameters
sysSDateFormat OBJECT-TYPE
SYNTAX INTEGER
{
ddMMYYYY (1),
mmDDYYYY (2),
yyyyMMDD (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the date and time format used for the
sysSDateAndTimeCmd and for the alarm buffer report."
::= { sysStatus 1 }
sysSDateCmd OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the current date as it is known by the
agent using its own real-time clock. The format would be as
specified by the sysSDateFormat.
This parameter can be set for time synchronization between
the NMS and the Agent.
* For KM-2100 V1 and FCD-T1/E1 - the string should contain
'/' signs between day, month and year. Example: 12/08/1998.
* For DXC and rest of the products - the string should contain
'-' signs between day, month and year. Example: 12-08-1998.
The day value will be in the range: 1..31.
The month value will be in the range: 1..12.
The year value will be in the range: 1996..2050 for products
supporting the '-' format."
::= { sysStatus 2 }
sysSTimeCmd OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the current time as it is known by the
agent using its own real-time clock.
This parameter can be set for time synchronization between
the NMS and the Agent.
The string should contain ':' signs between hour, minute
and second. Example: 11:05:58."
::= { sysStatus 3 }
sysSActiveCnfg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the configuration number,
that is currently active and running."
::= { sysStatus 4 }
-- return 1 (db1) in phase I
sysSEditCnfg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the unique configuration number that
is currently loaded into the tmp working space for
manipulation and update operations. Value of 255 means no
config. is under editing process."
::= { sysStatus 5 }
-- return 1 (db1) in phase I
sysSEditBy OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
snmp (2),
terCon1 (3),
terCon2 (4),
terInbandCon1 (5),
terInbandCon2 (6),
lcd (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates which MMI application is working on
the edited config.
The editing phase starts at the first modify operation and
ends after a load operation."
::= { sysStatus 6 }
sysSClkSrc OBJECT-TYPE
SYNTAX INTEGER
{
master (1),
fallback(2),
internal(3),
ml (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the source of the system clock."
::= { sysStatus 7 }
sysSAlrStatus OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
major (3),
minor (4),
event (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the current alarm state only for system level.
This object will be :
- critical(7): when there is at least one active (ON) critical
alarm .
- major (3): when there is no active critical alarm, but there is
at least one active (ON) major alarm .
- minor (4): when there is no active major or critical alarm, but
there is at least one active minor alarm.
- warning (6): when there is no active major, critical or minor alarm, but
there is at least one active warning alarm.
- event (5): when there is no active alarm of another type, but
there is at least one active event alarm.
- off(2): when there is no active (ON) alarm (since last clear operation)."
::= { sysStatus 8 }
sysSAlrStatusAll OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
major (3),
minor (4),
event (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the current alarm state including all levels:
system, card, port.
- critical(7): when there is at least one active (ON) critical
alarm .
- major (3): when there is no active critical alarm, but there is
at least one active (ON) major alarm .
- minor (4): when there is no active major or critical alarm, but
there is at least one active minor alarm.
- warning (6): when there is no active major, critical or minor alarm, but
there is at least one active warning alarm.
- event (5): when there is no active alarm of another type, but
there is at least one active event alarm.
- off(2): when there is no active (ON) alarm (since last clear operation)."
::= { sysStatus 9 }
sysSTestStatus OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the current test status (for all levels: system,
card, port).
This attribute will be set to:
- on(3): when there is at least one test in progress on the
system/card/port
otherwise the value will be off(2)."
::= { sysStatus 10 }
sysSSanityCheckStatus OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
fail (2),
warning (3),
ok (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Upon completion of the Sanity Check process on the TmpCnfg
this object will be set to:
- fail(2): when there is at least one error (which is
not just a warning) encountered
otherwise,
- warning(3): when there are only warnings
otherwise,
- ok(4).
The value should be unknown(1), if the TmpCnfg was changed
after the last Sanity check."
::= { sysStatus 11 }
sysSNoOfSanityCheckErr OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of errors/warnings
discovered by the last Sanity Check process."
::= { sysStatus 12 }
sysSErrListTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysSErrListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { sysStatus 13 }
sysSErrListEntry OBJECT-TYPE
SYNTAX SysSErrListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { sysSErrType, sysSErrIdx}
::= { sysSErrListTable 1}
SysSErrListEntry ::=
SEQUENCE {
sysSErrType INTEGER,
sysSErrIdx Integer32,
sysSErrDescription DisplayString
}
sysSErrType OBJECT-TYPE
SYNTAX INTEGER
{
error (1),
warning (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The errors are recorded in the agent, in two separate lists,
according to their type: error or warning."
::= { sysSErrListEntry 1}
sysSErrIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique index number to identify an entry in the error
or warning list .
The maximum value cannot exceed the value of
'sysSNoOfSanityCheckErr' (actually, the sum of the Errors
list max. index and the Warning list max. index should
equal the value of'sysSNoOfSanityCheckErr')."
::= { sysSErrListEntry 2}
sysSErrDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is a full text description of the sanity check
error including error code, IO slot and port numbers related to
the code ."
::= { sysSErrListEntry 3}
sysSMaxNoOfCnfg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum number of configurations that can be defined and
stored in the DACS agent.
If the DACS agent has a large capacity, the maximum will be
limited to 254."
::= { sysStatus 14 }
-- return 1 (db1) in phase I
sysSSelfTestResult OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The test is performed by the active Common Logic card.
The result will be a sum of 2**n according to the following
bit convention:
For DXC:
bit 0 Database 1 Checksum Error (LSB)
bit 1 Database 2 Checksum Error
bit 2 I/O Expander Error
bit 3 Counter Error
bit 4 Matrix DPR Error
bit 5 PS-A 5 Volt Error
bit 6 PS-A 12 Volt Error
bit 7 PS-B 5 Volt Error
bit 8 PS-B 12 Volt Error
bit 9 EPROM Failure
For FCD:
bit 0 I/O Expander Error (LSB)
bit 1 Counter Error
bit 2 EPROM Failure
bit 3 Illegal Sys Config
bit 4 SFIFO
bit 5 EPIC Failure (ISDN)
bit 6 XL Flash Fail -- for MSDSL interface
bit 7 XL MITEL Fail -- for MSDSL interface
bit 8 XL Framer Fail -- for MSDSL interface
bit 9 XL DSP Fail -- for MSDSL interface
For LRS52 - refer to product's spec
When a bit is ('1'), the error exists.
When NO ERROR is encountered, this object's value will be 0."
::= { sysStatus 15 }
sysSRelayState OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the current state of the alarm relay.
notApplicable - for agents that do not support this object."
::= { sysStatus 16 }
sysSInvertedAlr OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if there is any Inverted alarm at any level of the
system (sys, card, port).
notApplicable - for agents that do not support this object."
::= { sysStatus 17 }
--The following table reports all the Flip events due to I/O Redundancy
--since last Clear command of the table.
sysSRdnFlipTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysSRdnFlipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes all the Flip events due to I/O Redundancy since
last Clear command of this table."
::= { sysStatus 18 }
sysSRdnFlipEntry OBJECT-TYPE
SYNTAX SysSRdnFlipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { sysSRdnFlipIdx}
::= { sysSRdnFlipTable 1}
SysSRdnFlipEntry ::=
SEQUENCE {
sysSRdnFlipIdx Integer32,
sysSRdnFlipSlot INTEGER,
sysSRdnFlipPort Integer32,
sysSRdnFlipCause DisplayString,
sysSRdnFlipDate DisplayString,
sysSRdnFlipTime DisplayString
}
sysSRdnFlipIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique index number to identify an entry in the Redundancy Flip list."
::= { sysSRdnFlipEntry 1}
sysSRdnFlipSlot OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot number from which Flip was performed."
::= { sysSRdnFlipEntry 2}
sysSRdnFlipPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port number from which Flip was performed.
For DXC:
For external ports the convention used will be:
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
For internal ports the convention used will be:
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 .
For MP:
For external ports, the value will be as that of the port in the
card. Example: external-3 -> 3
external-4 -> 4
For internal ports, the value will be 100 + the port in the
card. Example: internal-1 -> 101
internal-4 -> 104
100=notApplicable (when Redundancy is at card level)."
::= { sysSRdnFlipEntry 3 }
sysSRdnFlipCause OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last cause that caused the Flip from the Slot (Port)
of sysSRdnSlot, sysSRdnPort."
::= { sysSRdnFlipEntry 4}
sysSRdnFlipDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Flip event Date. The format will be the one selected by user for
sysSDateFormat."
::= { sysSRdnFlipEntry 5}
sysSRdnFlipTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Flip event Time. The format will be hh:mm:ss."
::= { sysSRdnFlipEntry 6}
sysSRdnFlipTableClearCmd OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This command, when Set to 'on', clears the Redundancy Flip
table (sysSRdnFlipTable).
After clear is performed, the agent will turn the value to 'off'
automatically."
::= { sysStatus 19 }
sysSRdnFlipCmd OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables the user to send a command to the Agent, to Flip
from a current Online IO card to its Redundant card.
The value sent will be an Object Identifier of an entry in the sysCRdnTable.
This entry defines the Redundant couple of Slots on which the Flip
is applied.
Setting this object, will cause the Agent to Flip from current Online
card to its Redundant card.
This manual flip command is applicable only for entries having
Redundancy Mode=Y Cable.
For Vmux: This command will cause flipping from Secondary or Third Link to the
Primary Link. If the active link is the primary link, the agent will flip to the
secondary link. The value sent will be the Object Identifier of the following
Table: agnCBuMlTable.
Agent will send the value 0 for Get."
::= { sysStatus 20}
sysSBusTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysSBusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes data and status about the internal DXC BUS."
::= { sysStatus 21 }
sysSBusEntry OBJECT-TYPE
SYNTAX SysSBusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { sysSBusPortIdx}
::= { sysSBusTable 1}
SysSBusEntry ::=
SEQUENCE {
sysSBusPortIdx Integer32,
sysSBusStatus INTEGER,
sysSBusCapturePort Integer32,
sysSBusUtilization Integer32
}
sysSBusPortIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DXC BUS port number:
- first two digits will be: (IO slot number+10)
- last one/two digits will be the Bus port number, in odd numbers:
port1 = 1
port2 = 3
Example: port2 of IO slot 11 will be: 213."
::= { sysSBusEntry 1 }
sysSBusStatus OBJECT-TYPE
SYNTAX INTEGER
{
free (1),
physical(2),
virtual (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Status of sysSBusPortIdx.
free - not used
physical - captured by the port of the card physically installed
virtual - captured virtually by another port. Example: DIM port
(by Destination) or by Transparent T3/E3 port."
::= { sysSBusEntry 2}
sysSBusCapturePort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Port that Captured the sysSBusPortIdx.
- if sysSBusStatus=free, the value will be 'none'=0
- else, if sysSBusStatus=fixed, the value will be: sysSBusPortIdx
- else, the value will be according to the port index that captured
this Bus Port (according to DXC port index convention):
- xx1, xx3, xx11, xx13, xx31, xx33, xx2..xx56(even numbers)
- xx = (IO slot number+10) "
::= { sysSBusEntry 3}
sysSBusUtilization OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Utilization of sysSBusPortIdx resources, in percent [%]."
::= { sysSBusEntry 4}
--IO Redundancy - Commands
--sysSRdnCmdTable was moved to be after sysCRdnTable, in order to solve
--an SNMPc limitation regarding forward reference of the indexes.
sysSAlrAttrIndication OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the status of the Alarm Attributes
for the whole device.
It is a sum of 2**(Bit-1). A Bit will be '1', when any alarm in the
device is Filtered/Masked/Inverted (respectively).
The Bit assignment is:
Bit 1: Filter (LSB)
Bit 2: Mask
Bit 3: Invert (MSB).
Examples:
- Alarms are filtered and masked but not inverted: value=3
- Alarm is Inverted (not filtered or masked): value=4
- Alarm is masked (not inverted or filtered): value=2 "
::= { sysStatus 23 }
--System Current Alarm Table
--
--This table contains all Events and only the major/minor alarms
--whose status is ON.
sysSAlrTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysSAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of system level current existing alarms ."
::= { sysCurrentAlr 1 }
sysSAlrEntry OBJECT-TYPE
SYNTAX SysSAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { sysSAlrIdx}
::= { sysSAlrTable 1}
SysSAlrEntry ::=
SEQUENCE {
sysSAlrIdx Integer32,
sysSAlrCode Integer32,
sysSAlrState INTEGER, --Severity
sysSAlarmMask INTEGER,
sysSAlarmInvert INTEGER,
sysSAlarmOnOff INTEGER,
sysSAlarmCounter Integer32
}
sysSAlrIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index number of the current system alarms."
::= { sysSAlrEntry 1 }
sysSAlrCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a code related to a specific
alarm description. The list of codes and their related
descriptions will be sent to NMS request (for display purpose)
by alrGenTable."
::= { sysSAlrEntry 2 }
sysSAlrState OBJECT-TYPE
SYNTAX INTEGER {
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the alarm Severity."
::= { sysSAlrEntry 3 }
sysSAlarmMask OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Mask is : on/off."
::= { sysSAlrEntry 4 }
sysSAlarmInvert OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Invert is : on/off."
::= { sysSAlrEntry 5 }
sysSAlarmOnOff OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm state is : on/off."
::= { sysSAlrEntry 6 }
sysSAlarmCounter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A counter - how many times the alarm occured (ON) since last
clear operation or since last Reset."
::= { sysSAlrEntry 7 }
sysSAlrClearCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON, will enforce a clear
operation on the system level alarms . Upon completion,
the value will automatically change to off(2)."
::= { sysCurrentAlr 2 }
sysSAlrClearAllCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON, will enforce a clear
operation on all levels alarms . Upon completion,
the value will automatically change to off(2)."
::= { sysCurrentAlr 3 }
sysSAlrMaskAll OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"on(3) - will cause masking of all the system level alarms.
These alarms will not be sent to NMS and will not
be taken into account for Alarms Status.
off(2) - will unmask all system level alarms except those
masked via the sysSAlrMask. "
::= { sysCurrentAlr 4 }
sysSAlrMask OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (8))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is a mask that indicates which system level
alarms are masked. The masked alarms (their bit is set to
'1') are neither sent to the manager, nor taken into account
for alarm status and LEDs.
Bit no. = Alarm code
The bits that do not belong to the system level will be 0.
This object is applicable only when sysSAlrMaskAll=off
(otherwise all system alarms are masked).
Example: When Alarms having the codes 6 and 11 are masked,
the value of this object will be 840 (hex)."
::= { sysCurrentAlr 5 }
sysSAlrDataUpdateCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"on(3) - will cause Update of the Alarms Severity, Attributes and Report
tables.
off(2) - Upon completion, the value will automatically change to off(2)."
::= { sysCurrentAlr 6 }
--System Buffer Alarm Table
--
--This table contains all Events and all the major/minor alarms
--The buffer is cyclic and contains the most recent alarms.
--Since this table contains also the alarms occurence time,
--(appearance/disappearance for major/minor alarms), an alarm may
--appear several times in this table, with alternate state: major,
--off, major, etc..
sysBufferAlrTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysBufferAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of current existing alarms (of all levels)."
::= { sysBufferAlr 1 }
sysBufferAlrEntry OBJECT-TYPE
SYNTAX SysBufferAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { sysBufferAlrIdx}
::= { sysBufferAlrTable 1}
SysBufferAlrEntry ::=
SEQUENCE {
sysBufferAlrIdx Integer32,
sysBufferAlrCode Integer32,
sysBufferAlrState INTEGER,
sysBufferAlrSlot INTEGER,
sysBufferAlrPort Integer32,
sysBufferAlrDate DisplayString,
sysBufferAlrTime DisplayString,
sysBufferAlrUpTime TimeTicks,
sysBufferAlrInfo SnmpAdminString
}
sysBufferAlrIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index number of the current alarms."
::= { sysBufferAlrEntry 1 }
sysBufferAlrCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a code related to a specific
alarm description. The list of codes and thir related
descriptions will be known by the NMS (for display purpose)
and will appear in the unit's user manual."
::= { sysBufferAlrEntry 2 }
sysBufferAlrState OBJECT-TYPE
SYNTAX INTEGER {
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the alarm type.
minor/major/warning/critical - indicates appearance of the problem
and the type.
event - indicates occurence of an event.
off - indicates disappearance of an alarm. "
::= { sysBufferAlrEntry 3 }
sysBufferAlrSlot OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
local (20),
psC (21),
kmxPsA (101),
kmxPsB (102),
kmxMlA (103),
kmxMlB (104),
kmxCl (105),
kmxOpt (106),
kmxIO1 (107),
kmxIO2 (108),
kmxIO3 (109),
kmxIO4 (110),
kmxIO5 (111),
kmxIO6 (112),
kmxIO7 (113),
kmxIO8 (114),
kmxIO9 (115),
kmxIO10(116),
kmxIO11(117),
kmxIO12(118),
remote (120),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot number this alarm refers to.
When the alarm refers to a system function OR the DACS agent
is a stand-alone unit, the value will be 'notApplicable(255)'.
local/remote - for OP-4 device."
::= { sysBufferAlrEntry 4 }
sysBufferAlrPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port number this alarm refers to.
If the port number is irrelevant to this alarm (if it is
a system/card level alarm) the value will be 9999."
::= { sysBufferAlrEntry 5 }
sysBufferAlrDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date when the alarm occured. The format will be according
to sysSDateFormat."
::= { sysBufferAlrEntry 6 }
sysBufferAlrTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time when the alarm occured."
::= { sysBufferAlrEntry 7 }
sysBufferAlrUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time when the alarm occured.
This parameter holds the sysUpTime value when the alarm occured."
::= { sysBufferAlrEntry 8 }
sysBufferAlrInfo OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter includes information about the alarm (additional to the Description)."
::= { sysBufferAlrEntry 9}
sysBufferAlrClearCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON, will enforce a clear
operation on the Alarms Buffer. Upon completion,
the value will automatically change to off(2)."
::= { sysBufferAlr 2 }
--System Configuration Parameters
sysCClkSrcTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysCClkSrcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"All the entries of this table are identical (have the
same value) for all the configurations (1..255) except
the TmpCnfg.
For devices with more than one configuration:
The write operation into the Table Objects is valid only
for the TmpCnfg entry."
::= { sysConfig 1}
sysCClkSrcEntry OBJECT-TYPE
SYNTAX SysCClkSrcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {sysCClkCnfgIdx, sysCClkSrcIdx}
::= { sysCClkSrcTable 1}
SysCClkSrcEntry ::=
SEQUENCE {
sysCClkCnfgIdx Integer32,
sysCClkSrcIdx INTEGER,
sysCClkSrcMode INTEGER,
sysCClkSrcPrt Integer32,
sysCClkStationFreq INTEGER,
sysCClkRevertiveTimeout Integer32,
sysCClkStationIf INTEGER,
sysCClkStationCableMode INTEGER,
sysCClkStationOutState INTEGER,
sysCClkSsmBased INTEGER,
sysCClkSSubsystemSlot INTEGER,
sysCClkRecoveredID Unsigned32
}
sysCClkCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg being
accessed ; Idx of 255 relates to the TmpCnfg.
It can be also a combination of the configuration number and the
Card/Port/Other System index."
::= { sysCClkSrcEntry 1}
sysCClkSrcIdx OBJECT-TYPE
SYNTAX INTEGER
{
master (1),
fallback (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index in the table. There are only two entries in the
table.
master - refers Master clock parameters
fallback - refers Fallback clock parameters"
::= { sysCClkSrcEntry 2}
sysCClkSrcMode OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
internal (2),
rxClk (3),
station (4), -- station A (for IPmux1000)
lbt (5),
ntr (6),
adaptive (7),
stationB (8),
automatic (9),
system (10),
sSubSystem (11),
recovered (12),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates the source the nodal timing is
locked to.
none - is an invalid option for Master clock.
internal - is an invalid option for Fallback clock .
station - is an invalid option for a stand-alone unit.
lbt - loop-back timing
ntr - Network Time Reference
adaptive - clock locking is achieved by altering the clock
according to the data load
system - irrelevant when sysCClkCnfgIdx refers to System Clock.
sSubSystem - SONET/SDH Sub System.
recovered - clock recovery.
notApplicable - for ML source of Kmux or ML Timing
combinations when Master/Fallback clock are
not applicable."
::= { sysCClkSrcEntry 3}
sysCClkSrcPrt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry is valid only when working in rxClk mode
(for IPmux1000 this entry will be valid whe working in LBT mode).
For ACE2002 in case of invalid entry the return value
will be 0.
For other products in case of invalid entry the return
value will be 9999.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside,
SP.
* The SP ports will be numbered as follows:
- SP port 1 : 1
- SP port 2 : 2
For external ports the convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
For internal ports the convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 .
For Kmux, the port will be according to : Slot*100+Ch.
For ACE2002, LA140 and IPmux1000 (GMUX), the port will be ifIndex."
::= { sysCClkSrcEntry 4}
sysCClkStationFreq OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
f1544Khz (2), -- DS1
f2048Khz (3) -- E1
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates the frequency of the station clock
when the source is 'station'.
The value will be applicable only when the sysCClkSrcMode is
'station'. "
::= { sysCClkSrcEntry 5}
sysCClkRevertiveTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time in seconds in which the system will monitor the higher
level clock source, before decision to revert to that clock.
In case the time is zero, revertive mode will be disabled."
::= { sysCClkSrcEntry 6}
sysCClkStationIf OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
g703 (2), --E1 balanced
rs422 (3), --E1
g703E1Unbalanced (4),
g703T1 (5),
rs422T1 (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates the electrical interface connected to the
station clock, when the source is 'station'.
The value will be applicable only when the sysCClkSrcMode is
'station'. "
::= { sysCClkSrcEntry 7}
sysCClkStationCableMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
normal (2),
yCable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates whether both Station clocks get their
clock from the same source (Y Cable)or each one get its clock independently.
The value will be applicable only when the sysCClkSrcMode is 'station'. "
::= { sysCClkSrcEntry 8}
sysCClkStationOutState OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates whether station clock can
send its clock to another device.
The value will be applicable only when the sysCClkSrcMode is 'station'. "
::= { sysCClkSrcEntry 9}
sysCClkSsmBased OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates whether clock source
will be selected based on receive clock quality,
indicated in S1 byte inside SONET/SDH overhead,
(encoded as SSM - Synchronization Status Messaging).
It is relevant only for sysCClkSrcIdx=master.
When the value is Yes, sysCClkSrcMode must be notApplicable."
::= { sysCClkSrcEntry 10}
sysCClkSSubsystemSlot OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
clA (3),
clB (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates the Slot from which the S Subsytem Source
will be taken.
The value will be applicable only when the sysCClkSrcMode is
'sSubsystem'. "
::= { sysCClkSrcEntry 11}
sysCClkRecoveredID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates the Recovered Clock ID.
The value will be applicable only when sysCClkSrcMode is 'recovered'."
::= { sysCClkSrcEntry 12}
sysCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"All the entries of this table are identical (have the
same value) for all the configurations (1..255) except
the TmpCnfg.
The write operation into the Table Objects is valid only
for the TmpCnfg entry."
::= { sysConfig 2}
sysCnfgEntry OBJECT-TYPE
SYNTAX SysCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {sysCnfgIdx}
::= { sysCnfgTable 1}
SysCnfgEntry ::=
SEQUENCE {
sysCnfgIdx Integer32,
sysCMatrixMode INTEGER,
sysCIsdnFormat INTEGER,
sysCRoutingOnEth INTEGER,
sysCAutoConfigEnable INTEGER,
sysCIntTsAllocMode INTEGER,
sysCBuPrimaryPort INTEGER,
sysCEnableLanOverTdm INTEGER,
sysCSs7FisuSuppression Integer32,
sysCBuRecMode INTEGER
}
sysCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg(1..255) being
accessed ; Idx of 255 relates to the TmpCnfg.
For Gmux2000 the range limitation (1..255) was discarded
since the Idx is computed as: <IO Card No.> x 1000 + 255."
::= { sysCnfgEntry 1}
sysCMatrixMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
bidirectional (2),
unidirectional (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the TS Matrix Mode:
bidirectional - TS Assignment Matrix is symmetric.
unidirectional - TS Assignment Matrix can be asymmetric.
notApplicable - for agents that do not support this feature."
::= { sysCnfgEntry 2}
sysCIsdnFormat OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
te (2),
nt (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ISDN format. This parameter controls the operation mode of
the ISDN ports.
te - ISDN timing is derived from the signal received
from the equipment it is connected to.
nt - timing of the transmit path is locked to the nodal
timing source.
notApplicable - for agents that do not support this feature."
::= { sysCnfgEntry 3}
sysCRoutingOnEth OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
proprietary (3),
rip2 (4),
rip1 (5),
rip1and2 (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mng Routing Protocol on the online CL Ethernet port,
or on device Ethernet port dedicated for mangement."
::= { sysCnfgEntry 4}
sysCAutoConfigEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables user to enable/disable activating
the Auto Configuration. When Auto Configuration is activated,
the device learns its configuration Automatically from the Net
it is connected to."
::= { sysCnfgEntry 5}
sysCIntTsAllocMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
static (2),
dynamic (3),
staticOneToOne(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables user to select the mode of Internal TS
Allocation.
static - user has to select for each Dynamic card port, the
Maximum TSs expected to be connected (including future
growth). This number will be allocated to the ports,
so that if number of connected TSs will grow within
the limits of this Maximum TS limit, no disruption
of data flow will occur for other ports.
dynamic- TS allocation is done dynamically according to the
connected TSs. No future reservations are done. This mode
may cause data disruption on other ports/slots if user
will want to change the number of connected TSs for a
Dynamic card port.
staticOneToOne - user has to select for each Dynamic card port, the
Maximum TSs expected to be connected (including future
growth). In addition, the TSs themselves cannot be higher
than this defined Maximum (e.g if Maximum TSs=5 user cannot
selects TSs higher than 5). This mode ensures that if number
of TSs grow within the limits of this Maximum TS limit, no
disruption of data flow will occur for other ports AND for
the selected port itself.
Default=static(2). "
::= { sysCnfgEntry 6}
sysCBuPrimaryPort OBJECT-TYPE
SYNTAX INTEGER
{
noBackup (2),
e1T1orSerial (3),
eth (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables the user to configure a Backup mechanism.
If a backup mechanism exists, it is possible to configure the primary port.
The traffic will flow via the primary port when the port functionality is OK.
In Vmux-2100 device the backup mechanism is relevant for the Main Board only.
The primary port can be the E1/T1/Serial port or the ETH port. "
::= { sysCnfgEntry 7}
sysCEnableLanOverTdm OBJECT-TYPE
SYNTAX INTEGER
{
enableAll (2),
enableVoiceOnly (3),
enableVoiceAndMng (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables/disables transferring traffic from the LAN port
to the TDM port. It is possible to enable only part of the traffic on the
TDM port for security reasons or in order to minimize the bandwidth ."
::= { sysCnfgEntry 8}
sysCSs7FisuSuppression OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SS7 Suppresion is used for SS7 Spoofing.
The SS7 spoofing terminates the keep alive messages from the local VMUX
without sending them over the network, thus improving the bandwidth utilization.
FISU means Fill in Service Unit - Keep alive that is sent when no one is talking
on the line.
This object enables the configuration of the SS7 Keep Alive packet % that will
be discarded.
Legal Values: 0 - No Suppression, 10%, 20%, 30% .. 90%
Example: For a value of 10, 1 keep alive packet will be discarded out of
10 keep alive packets that were supposed to be sent over the network."
::= { sysCnfgEntry 9}
sysCBuRecMode OBJECT-TYPE
SYNTAX INTEGER
{
auto (2),
manual (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Recovery Mode. This object determines if after recovery
of the Primary Link (used in Vmux) it will become on-line again or not:
auto - automatic. In this case, the failed Link will become
on-line again after recovery, automatically.
manual - In this case, the failed Link will not become
on-line again after recovery but user can manually flip
to this Link."
::= { sysCnfgEntry 10}
--System I/O Redundacy Table
--
--This table contains all I/O cards/ports that have redundancy,
--data about the redundant card/port and parameters regarding the
--redundancy operation.
--The table indexes are Cnfg and the Primary card&port
sysCRdnTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysCRdnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration of all Redundant I/O cards and ports.
The write operation into the table objects is valid only
for the TmpCnfg.
A Slot/Port that have no Redundancy, will not exist in this
table."
::= { sysConfig 3 }
sysCRdnEntry OBJECT-TYPE
SYNTAX SysCRdnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { sysCRdnCnfgIdx, sysCRdnPrimeSlot, sysCRdnPrimePort}
::= { sysCRdnTable 1}
SysCRdnEntry ::=
SEQUENCE {
sysCRdnCnfgIdx Integer32,
sysCRdnPrimeSlot INTEGER,
sysCRdnPrimePort Integer32,
sysCRdnSecSlot INTEGER,
sysCRdnSecPort Integer32,
sysCRdnMode INTEGER,
sysCRdnRecMode INTEGER,
sysCRdnRecTime Integer32,
sysCRdnHwSwFlip INTEGER,
sysCRdnRowStatus RowStatus,
sysCRdnOnline INTEGER,
sysCRdnSwitchingMode INTEGER,
sysCRdnFlipUponEvent Integer32,
sysCRdnLosOrLofTime Integer32,
sysCRdnEventsTimeWindow Integer32,
sysCRdnSequenceNumberThreshold Integer32,
sysCRdnBufferErrorsThreshold Integer32,
sysCRdnBuffUnderrunTime Integer32,
sysCRdnPrimePriority INTEGER,
sysCRdnSecPriority INTEGER,
sysCRdnWTR Unsigned32,
sysCRdnName SnmpAdminString,
sysCRdnTxDownDurationUponFlip Unsigned32
}
sysCRdnCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg(1..255) being
accessed ; Idx of 255 relates to the TmpCnfg."
::= { sysCRdnEntry 1 }
sysCRdnPrimeSlot OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot number of the Primary card of Redundancy.
The Primary card should be the card that user wishes to be
the online card (usually the more important one).
For some Redundancy modes the importance of the redundant
cards/ports is the same. "
::= { sysCRdnEntry 2 }
sysCRdnPrimePort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port number.
For DXC:
For external ports the convention used will be:
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
For internal ports the convention used will be:
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 .
For MP:
For external ports, the value will be as that of the port in the
card. Example: external-3 -> 3
external-4 -> 4
For internal ports, the value will be 100 + the port in the
card. Example: internal-1 -> 101
internal-4 -> 104
For IP Bundles, the value will be the Bundle ifIndex. For an IP Bundle
that is in an External Device (not in this MP), the value will be:
70,000 + ifIndex of Secondary Bundle.
For other products - refer to product specification.
100=notApplicable (when Redundancy is at card level)."
::= { sysCRdnEntry 3 }
sysCRdnSecSlot OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
notApplicable (255)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The slot number of the Secondary card of Redundancy matching
the Primary slot."
::= { sysCRdnEntry 4 }
sysCRdnSecPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The port number.
For DXC:
For external ports the convention used will be:
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
For internal ports the convention used will be:
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 .
For MP:
For external ports, the value will be as that of the port in the
card. Example: external-3 -> 3
external-4 -> 4
For internal ports, the value will be 100 + the port in the
card. Example: internal-1 -> 101
internal-4 -> 104
For IP Bundles, the value will be the Bundle ifIndex. For an IP Bundle
that is in an External Device (not in this MP), the value will be: 0.
For other products - refer to product specification.
100=notApplicable (when Redundancy is at card level)."
::= { sysCRdnEntry 5 }
sysCRdnMode OBJECT-TYPE
SYNTAX INTEGER
{
dualCableAIS (2),
yCable (3),
dualCableParallelTx (4),
backup (5),
singleSlotProtection(6),
onePlusOne (7),
oneToOne (8),
linkAggregation (9), --802.3ad
manual (10)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Redundancy Mode.
DXC supports: yCable(3), singleSlotProtection(6) and dualCableParallelTx(4)
MP supports: yCable(3), dualCableParallelTx(4), onePlusOne(7) and oneToOne(8).
(dualCableAIS and backup were planned for MP but were not
implemented).
backup - will be used when a port is backup of more than one port.
IPmux: onePlusOne(7) and oneToOne(8) are used for Bundle redundancy."
::= { sysCRdnEntry 6 }
sysCRdnRecMode OBJECT-TYPE
SYNTAX INTEGER
{
auto (2),
manual (3),
nonRevertive(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Recovery Mode. This object determines if after recovery
of the failed Primary card/port it will become on-line again or not:
auto - automatic . In this case, the failed card/port will become
on-line again after recovery, automatically.
manual - In this case, the failed card/port will not become
on-line again after recovery. But, user can manually flip
to this card/port.
nonRevertive - same as manual, but here user CANNOT manually flip
to this card/port. It will become on-line again, only if the
Secondary/Backup card/port will fail."
::= { sysCRdnEntry 7 }
sysCRdnRecTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Redundancy Recovery Time (sec). After switching to the current
online card, the next switch can be performed only after a
minimum time, indicated by this object.
Valid Values: 0..300, 65535.
65535=NA.
This object is applicable only when sysCRdnRecMode=auto."
::= { sysCRdnEntry 8 }
sysCRdnHwSwFlip OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
hw (2),
sw (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"HW or SW decision for Redundancy Flip.
This object is applicable only for sysCRdnMode=singleSlotProtection.
HW - decision is by I/O card
SW - decision is by CL SW."
::= { sysCRdnEntry 9 }
sysCRdnRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter allows NMS to create/delete entries of this table.
The possible supported RowStatus values are
active (1) and destroy (6).
For Vmux-2100 the supported values are:
active (1), createAndGo (4) and destroy (6)."
::= { sysCRdnEntry 10 }
sysCRdnOnline OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
primary (2),
secondary (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status - who is the Online (current) Redundancy Slot/Port.
This object shows only the Online Slot/Port regarding the Redundancy.
mdlSActivity or prtGenActiveStatus of the same Slot/Port may be Offline."
::= { sysCRdnEntry 11 }
sysCRdnSwitchingMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
biDirectional (2), --1+1
uniDirectional (3), --1:1
linkAggregation (4) --802.3ad
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object defines which Self Healing Ring (SHR) SDH ring is used:
Uni Directional or BiDirectional. The type of the ring
is defined according to the direction of traffic flow under
normal working conditions.
In Bi Directional ring, the duplex traffic is on the same path
and transverses the same set of nodes for both directions of transmission.
In Uni Directional ring, the duplex traffic travels over opposite path
(per direction) and all the node of the ring are involved.
For Uni Directional SHR Protection Switching (Single Ended Switching)
is controlled by one node of the SDH ring, and does not require a protocol.
For Bi Directional SHR Protection Switching (Dual Ended switching)
is controlled by some nodes of the ring and requires a protocol"
::= { sysCRdnEntry 12 }
sysCRdnFlipUponEvent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object allows user to define if Flip to the other port will
be performed (or not), for certain possible events.
Each event is represented by a bit. The value of the object is a sum
of 2**n, according to the bits having '1' value.
'1' - means that Flip should occur due to this event.
Bit 0 (LSB) = SD (Signal Degraded).
For IPmux:
Bit 0 (LSB) = TDM Line LOS/LOF.
Bit 1 = Sequence Number.
Bit 2 = Jitter Buffer errors."
::= { sysCRdnEntry 13 }
sysCRdnLosOrLofTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter determines how much time to wait before switching,
after LOF or LOS are detected on the TDM Line.
For Ipmux time is counted in msec."
::= { sysCRdnEntry 14 }
sysCRdnEventsTimeWindow OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter determines the time window in which
to count events to trigger protection switching.
For Ipmux time is counted in seconds."
::= { sysCRdnEntry 15 }
sysCRdnSequenceNumberThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter determines the number of Sequence Number errors
that should occur in the time window in order to cause switching."
::= { sysCRdnEntry 16 }
sysCRdnBufferErrorsThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter determines the number of Buffer undeflow/ overflow events
occured in the time window that cause switching."
::= { sysCRdnEntry 17 }
sysCRdnBuffUnderrunTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter determines how much time to wait before switching,
after jitter buffer underrun.
Switching occurs if no frame arrives within that time.
For Ipmux time is counted in msec."
::= { sysCRdnEntry 18 }
sysCRdnPrimePriority OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
low (2),
high (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Primary port priority.
In ETX2xx/2xxA:
When selecting sysCRdnMode = manual (10),
this parameter determines the forced active port:
low - means that the secondary port is selected to be active
high - means that the primary port is selected to be active. "
::= { sysCRdnEntry 19 }
sysCRdnSecPriority OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
low (2),
high (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Secondary port priority."
::= { sysCRdnEntry 20 }
sysCRdnWTR OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Redundancy Wait to Restore (sec).
Valid Values: 0..999, 65535.
65535=NA.
When the value <> 65535, the value of sysCRdnRecTime must be 65535."
::= { sysCRdnEntry 21 }
sysCRdnName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A textual name for the redundancy group."
::= { sysCRdnEntry 22 }
sysCRdnTxDownDurationUponFlip OBJECT-TYPE
SYNTAX Unsigned32 (0..30)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object defines the duration (in seconds) the active
port transmission is shut down after flip occurs.
The transmission is shut down and then opened again (after the duration
defined by this object), in order to cause the other side to flip
to the new active port.
0 = no shut-down.
This object is applicable only when sysCRdnMode = oneToOne(8)
and mainly when each of the links of our device is connected to a different device."
::= { sysCRdnEntry 23 }
--IO Redundancy - Commands
--This table was moved here, so that its indexes will be defined before,
--for SNMPc
sysSRdnCmdTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysSRdnCmdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes commands used for IO Redundancy."
::= { sysStatus 22 }
sysSRdnCmdEntry OBJECT-TYPE
SYNTAX SysSRdnCmdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {sysCRdnPrimeSlot, sysCRdnPrimePort }
::= { sysSRdnCmdTable 1}
SysSRdnCmdEntry ::=
SEQUENCE {
sysSRdnEnforcedChannel INTEGER,
sysSRdnLockFlip INTEGER,
sysSRdnManualFlip INTEGER
}
sysSRdnEnforcedChannel OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
noEnforcement (2),
primary (3),
secondary (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is a command to override all switching considerations
and enforce use of primary/ secondary connection only.
noEnforcement - cancels the state of override and goes back to
usual switching considerations.
Default = noEnforcement(2)."
::= {sysSRdnCmdEntry 1 }
sysSRdnLockFlip OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is a command to lock the Redundancy flip for this redundancy couple.
Default = off(2)."
::= {sysSRdnCmdEntry 2 }
sysSRdnManualFlip OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is a command to move to manual Redundancy flip mode for this redundancy couple.
Default = off(2)."
::= {sysSRdnCmdEntry 3 }
--System Database operations
sysDbaseSanityCheckCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on(3) will initiate the process
of Sanity check on the TmpCnfg. Upon completion, the value
will automatically change to off(2)."
::= { sysDbase 1 }
sysDbaseDownloadCnfgIdxCmd OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute specifies the Id of the target RealCnfg to
which the TmpCnfg should be transferred. Upon set command,
the DACS agent will initiate the Sanity-Check process.
If successful, the actual transfer will be performed.
If there will be errors, the user will have to perform
the command again after errors correction.
The operation is valid only on configuration numbers
that do not exceed sysSMaxNoOfCnfg."
::= { sysDbase 2 }
-- In phase I of DXC and FCD only the value 1 (Cnfg1) is valid.
sysDbaseUploadCnfgIdxCmd OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute specifies the Id of the source Cnfg to be
loaded into the TmpCnfg. Upon set operation the actual
transfer will be initiated.
The operation is valid only on configuration numbers
that do not exceed sysSMaxNoOfCnfg."
::= { sysDbase 3 }
-- In phase I of DXC and FCD only the value 1 (Cnfg1) is valid.
sysDbaseFlipTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysDbaseFlipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Dbase Flip time and activation for every configuration."
::= { sysDbase 4 }
sysDbaseFlipEntry OBJECT-TYPE
SYNTAX SysDbaseFlipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {sysDbaseFlipIdx}
::= { sysDbaseFlipTable 1}
SysDbaseFlipEntry ::=
SEQUENCE {
sysDbaseFlipIdx Integer32,
sysDbaseFlipTime DisplayString,
sysDbaseFlipActivation INTEGER }
sysDbaseFlipIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg being
the target Configuration."
::= { sysDbaseFlipEntry 1}
sysDbaseFlipTime OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the time (HH:MM) when this data
base will start being used by the Tmp config."
::= { sysDbaseFlipEntry 2}
sysDbaseFlipActivation OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates if the Dbase flip will be
activated at the time specified for this configuration
(enable) or not (disable).
No more than one flip should be enabled for the same time."
::= { sysDbaseFlipEntry 3}
--Module (card) level of DACS MIB
mdlGen OBJECT IDENTIFIER ::= {mdlDacsMux 1}
mdlCl OBJECT IDENTIFIER ::= {mdlDacsMux 2}
mdlPs OBJECT IDENTIFIER ::= {mdlDacsMux 3}
--DACS module (card) general parameters (common to all cards
--type)
--General Card - Status information table
--This table is NOT-APPLICABLE for a stand-alone unit
mdlSTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { mdlGen 1 }
mdlSEntry OBJECT-TYPE
SYNTAX MdlSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mdlSSltIdx }
::= { mdlSTable 1}
MdlSEntry ::=
SEQUENCE {
mdlSSltIdx INTEGER,
mdlSCardType INTEGER,
mdlSHwVer DisplayString,
mdlSSwVer DisplayString,
mdlSAlarmStatus INTEGER,
mdlSAlarmStatusAll INTEGER,
mdlSTestStatus INTEGER,
mdlSHwStatus INTEGER,
mdlSActivity INTEGER,
mdlSAlrClearCmd INTEGER,
mdlSAlrClearAllCmd INTEGER,
mdlSAlrMaskAll INTEGER,
mdlSCmd Integer32,
mdlSReset INTEGER,
mdlSRebuildFrame INTEGER,
mdlSBackupSwVer DisplayString,
mdlSSecondaryBackupSwVer DisplayString,
mdlSPiggybackVer SnmpAdminString
}
mdlSSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
psC (20),
kmxPsA (101),
kmxPsB (102),
kmxMlA (103),
kmxMlB (104),
kmxCl (105),
kmxOpt (106),
kmxIO1 (107),
kmxIO2 (108),
kmxIO3 (109),
kmxIO4 (110),
kmxIO5 (111),
kmxIO6 (112),
kmxIO7 (113),
kmxIO8 (114),
kmxIO9 (115),
kmxIO10(116),
kmxIO11(117),
kmxIO12(118),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify a slot position in the DACS.
The Kilomux should use enumerated values starting with kmx.
For IPmux100 use values 1-13, 20."
::= { mdlSEntry 1}
mdlSCardType OBJECT-TYPE
SYNTAX INTEGER
{
--
-- General types
--
unknown (1),
empty (2),
-- Power Supply Modules
--
psAC (10),
psDC (11),
--
-- Cl Modules
--
gCl1 (18), -- IPmux1000 CL1
gCl2 (19), -- IPmux1000 CL2
dCl (20),
kCl (21),
dcl2 (22),
dcl2Eth (23),
kClEth (24),
dcl3 (25),
dcl3Eth (26),
--
-- T1/E1 Modules
--
d4T1 (28),
d8T1 (29),
dT1DSU (30),
dT1CSU (31),
dE1DSU (32),
dE1LTU (33),
dE1aDSU (34),
dE1aLTU (35),
dT1F (36),
dE1F (37),
d4E1 (38),
d8E1 (39),
--
-- xDSL Modules
dE1Hdsl (40), --Double Slot
dT1Hdsl (41), --Double Slot
dE1HdslS (42), --Single Slot
dT1HdslS (43), --Single Slot
d16gsdsl (44), --Single Slot, for DXC3000 only
d8sl (45), --Single Slot
d4slStuC (46), --Single Slot
d4slStuR (47), --Single Slot
-- KMUX Main Links
--
kML1 (50),
kML2 (51),
kML3 (52),
kML4 (53),
kML5 (54),
kML6 (55),
kML7 (56),
kML8 (57),
kML10 (59),
kMLF (60),
kML10New (61),
kML11RJ45 (62),
kML11FO (63),
--LS Modules
--
kLS1 (70),
kLS1New (71),
kLS2 (72),
--LAN Modules
--
kTRE (80),
kMBE (81),
kMBENew (82),
fLAN (83), -- FCD STM LAN card
--Optional Modules
--
kai (90),
kdi (91),
kdiCH (92),
-- HS Modules
--
dHS2 (100),
d8U (101),
d16U (102),
d4HS (103),
d8HS (104),
kHS1 (110),
kHS2 (111),
kHSU1 (112),
kHSU2 (113),
kHS703 (114),
-- Voice Modules
--
kVC1EM (130),
kVC1FXO (131),
kVC1FXS (132),
kVC1MEM (133),
kVC1MFXO (134),
kVC1MFXS (135),
kVC1MFXSW (136),
kVC2EM (137),
kVC2FXO (138),
kVC2FXS (139),
kVC2s1EM (140), --KVC2/1/E&M
kVC2s1FXO (141), --KVC2/1/FXO
kVC2s1FXS (142), --KVC2/1/FXS
kVC3EM (143),
kVC3FXO (144),
kVC3FXS (145),
kVC3S0 (146),
-- Fax Modules
--
kVF1EM (170),
kVF1FXO (171),
kVF1FXS (172),
kVF3EM (173),
kVF3FXO (174),
kVF3FXS (175),
kVF4EM (176),
kVF4FXO (177),
kVF4FXS (178),
kVF4FXSW (179),
kVF4S0 (180),
kVF5PbxE1 (181),
kVF5E1PbxSlave (182),
kVF5PbxT1 (183),
kVF5T1PbxSlave (184),
kVF5PbxE1New (185),
kVF5E1PbxSlaveNew (186),
kVF5PbxT1New (187),
kVF5T1PbxSlaveNew (188),
kVF4FXO3 (189),
kVF4FXS3 (190),
kVF4NS0 (191),
kVF6E1s16 (192), --KVF.6/E1/16
kVF6E1s31 (193), --KVF.6/E1/31
kVF6T1s12 (194), --KVF.6/T1/12
kVF6T1s24 (195), --KVF.6/T1/24
kVF8EM (196),
kVF8FXO (197),
kVF8FXS (198),
-- DIM Modules
--
dimETUR (200),
dimV35 (201),
dimRS422 (202),
dimRS530 (203),
dimHssi (204),
dimX21 (205),
dim10BaseT (206),
dimE1 (207),
dim100 (208),
--DACS T3/E3 Modules
--
dt3G747 (209),
dt3 (210),
dt3f (211),
de3 (212),
de3f (213),
-- STM-1 Modules
--
dstm1s1 (214), --DSTM1/1 Fractional
dstm1s2 (215), --DSTM1/2 Fractional + Redundancy
fSTM1 (216), -- FCD STM STM1 card
dstm1 (217), --DSTM1 Full
dstm1R (218), --DSTM1 Full + Redundancy
f2stm1 (219), -- FCD STM 2 STM1 ports card
gstm1 (220), -- IPmux1000 (GMUX) STM1 card
goc3 (221), -- IPmux1000 (GMUX) OC3 card
gstm1D (222), -- IPmux1000 (GMUX) STM1 card with 2 ports
goc3D (223), -- IPmux1000 (GMUX) OC3 card with 2 ports
-- LA Modules
--
laSUB (230), -- La-240
laVEM (231), -- LA-140 & La-240
laVFXO (232), -- LA-140 & La-240
laVFXS (233), -- LA-140 & La-240
laV11 (234), -- LA-140 & La-240
laV24 (235), -- LA-140 & La-240
laV35 (236), -- LA-140 & La-240
laT1 (237), -- LA-140
laT1Vxx (238), -- LA-140
laE1 (239), -- LA-140
laE1Vxx (240), -- LA-140
laISDN (241), -- LA-140 & La-240i
laVxx (242), -- LA-140
laEth (243), -- LA-140
laISDNwBU (244), -- LA-140 with backup (lifeline bottom connector)
laIsdnNT (245), -- LA-140 ISDN NT
laIsdnNTwBU (246), -- LA-140 ISDN NT with backup (lifeline bottom connector)
laIsdnTE (247), -- LA-140 ISDN TE
laFXSwBU (248), -- LA-140 FXS with backup (lifeline bottom connector)
laFXSs (249), -- LA-140 bottom row FXS
laFXSwBUs (250), -- LA-140 bottom row FXS with backup (lifeline Top port)
laIsdnNTs (251), -- LA-140 bottom row ISDN NT
laIsdnNTwBUs (252), -- LA-140 bottom row ISDN NT with backup (lifeline Top port)
laIsdnTEs (253), -- LA-140 bottom row ISDN TE
laDp (254), -- LA-140 bottom single data port X21/V35/RS50
laSdsl (255), -- LA-140 top SDSL port
laSdslDp (256), -- LA-140 top SDSL port with bottom X21 or V35 Data Port
laAdslA (257), -- LA-140 bottom ADSLA port
laAdslADp (258), -- LA-140 bottom ADSLA port with top X21 or V35 Data Port
laAdslB (259), -- LA-140 bottom ADSLB port
laAdslBDp (260), -- LA-140 bottom ADSLB port with top X21 or V35 Data Port
laShdsl (261), -- LA-140 bottom SHDSL port
laShdslDp (262), -- LA-140 bottom SHDSL port with top X21 or V35 Data Port
laT1b (263), -- LA-140 bottom T1 port
laT1bDp (264), -- LA-140 bottom T1 port with top data port
laIsdnTEwBU (265), -- LA-140 ISDN TE with backup
laIsdnTEwBUs (266), -- LA-140 bottom row ISDN TE with backup
laShdsl4w (267), -- LA-140 bottom 4 wires SHDSL port
laShdsl4wDp (268), -- LA-140 bottom 4 wires SHDSL port with top Data Port
laEthSwitch (269), -- FCD-IPM
-- Server Modules
--
serverE1 (270), -- IPmux1000 (GMUX) Server E1 Card
serverT1 (271), -- IPmux1000 (GMUX) Server T1 Card
serverE1Pw (272), -- Gmux2000 Server E1 PW Card
serverT1Pw (273), -- Gmux2000 Server T1 PW Card
-- GiGabit ETH Modules
--
gigabitEth (280), -- Gmux2000 Gigabit ETH Card
gigabitEth2 (281), -- Gmux2000 new Gigabit ETH Card - 2 GbE ports with SFP connector
eth2 (282), -- Gmux2000 new ETH Card - 2 ETH ports with RJ45 connectors (10/100/1000)
gigabitEth8 (283), -- Gmux2000 new Gigabit ETH Card - 8 GbE ports with SFP connector
eth8 (284), -- Gmux2000 new ETH Card - 8 ETH ports with RJ45 connectors (10/100/1000)
-- CT3 Modules
--
channelizedT3Pw1 (290), -- Gmux2000 Channelized T3 PW Card
-- T1/E1 Modules
--
cesT128 (300), -- Gmux2000 CES T1 28 ports (external T1 ports) card.
cesE128 (301), -- Gmux2000 CES E1 28 ports (external E1 ports) card.
cesT1Pw28 (302), -- Gmux2000 CES T1 PW ports (external T1 ports) card.
cesE1Pw28 (303), -- Gmux2000 CES E1 PW ports (external E1 ports) card.
-- Vmux Modules
--
vmxE1VeDe (310), -- Gmux-2000 Vmux E1 card with 16 external voice + 2 external Data ports.
vmxE1VeDi (311), -- Gmux-2000 Vmux E1 card with 16 external voice + 2 internal Data ports.
vmxE1ViDe (312), -- Gmux-2000 Vmux E1 card with 16 internal voice + 2 external Data ports.
vmxE1ViDi (313), -- Gmux-2000 Vmux E1 card with 16 internal voice + 2 internal Data ports.
vmxT1VeDe (314), -- Gmux-2000 Vmux T1 card with 16 external voice + 2 external Data ports.
vmxT1VeDi (315), -- Gmux-2000 Vmux T1 card with 16 external voice + 2 internal Data ports.
vmxT1ViDe (316), -- Gmux-2000 Vmux T1 card with 16 internal voice + 2 external Data ports.
vmxT1ViDi (317), -- Gmux-2000 Vmux T1 card with 16 internal voice + 2 internal Data ports.
vc12E1UeNe (318), -- Gmux-2000 Vmux E1 card with 12 external User (voice) + 2 external Network (Data) ports.
vc12E1UeNi (319), -- Gmux-2000 Vmux E1 card with 12 external User (voice) + 2 internal Network (Data) ports.
vc12E1UiNe (320), -- Gmux-2000 Vmux E1 card with 12 internal User (voice) + 2 external Network (Data) ports.
vc12E1UiNi (321), -- Gmux-2000 Vmux E1 card with 12 internal User (voice) + 2 internal Network (Data) ports.
vc12T1UeNe (322), -- Gmux-2000 Vmux T1 card with 12 external User (voice) + 2 external Network (Data) ports.
vc12T1UeNi (323), -- Gmux-2000 Vmux T1 card with 12 external User (voice) + 2 internal Network (Data) ports.
vc12T1UiNe (324), -- Gmux-2000 Vmux T1 card with 12 internal User (voice) + 2 external Network (Data) ports.
vc12T1UiNi (325), -- Gmux-2000 Vmux T1 card with 12 internal User (voice) + 2 internal Network (Data) ports.
-- New Vmux Card Types
--
vca16E1UeNe (326), -- Gmux-2000 VCA E1 card with 16 external User (voice) + 2 external Network (Data) ports.
vca16E1UeNi (327), -- Gmux-2000 VCA E1 card with 16 external User (voice) + 2 internal Network (Data) ports.
vca16E1UiNe (328), -- Gmux-2000 VCA E1 card with 16 internal User (voice) + 2 external Network (Data) ports.
vca16E1UiNi (329), -- Gmux-2000 VCA E1 card with 16 internal User (voice) + 2 internal Network (Data) ports.
vca16T1UeNe (330), -- Gmux-2000 VCA T1 card with 16 external User (voice) + 2 external Network (Data) ports.
vca16T1UeNi (331), -- Gmux-2000 VCA T1 card with 16 external User (voice) + 2 internal Network (Data) ports.
vca16T1UiNe (332), -- Gmux-2000 VCA T1 card with 16 internal User (voice) + 2 external Network (Data) ports.
vca16T1UiNi (333), -- Gmux-2000 VCA T1 card with 16 internal User (voice) + 2 internal Network (Data) ports.
vca12E1UeNe (334), -- Gmux-2000 VCA E1 card with 12 external User (voice) + 2 external Network (Data) ports.
vca12E1UeNi (335), -- Gmux-2000 VCA E1 card with 12 external User (voice) + 2 internal Network (Data) ports.
vca12E1UiNe (336), -- Gmux-2000 VCA E1 card with 12 internal User (voice) + 2 external Network (Data) ports.
vca12E1UiNi (337), -- Gmux-2000 VCA E1 card with 12 internal User (voice) + 2 internal Network (Data) ports.
vca12T1UeNe (338), -- Gmux-2000 VCA T1 card with 12 external User (voice) + 2 external Network (Data) ports.
vca12T1UeNi (339), -- Gmux-2000 VCA T1 card with 12 external User (voice) + 2 internal Network (Data) ports.
vca12T1UiNe (340), -- Gmux-2000 VCA T1 card with 12 internal User (voice) + 2 external Network (Data) ports.
vca12T1UiNi (341), -- Gmux-2000 VCA T1 card with 12 internal User (voice) + 2 internal Network (Data) ports.
vmg16E1Ue (342), -- Gmux-2000 VMG (Media Gateway) E1 card with 16 external User ports
vmg16E1Ui (343), -- Gmux-2000 VMG (Media Gateway) E1 card with 16 internal User ports
vmg16T1Ue (344), -- Gmux-2000 VMG (Media Gateway) T1 card with 16 external User ports
vmg16T1Ui (345), -- Gmux-2000 VMG (Media Gateway) T1 card with 16 internal User ports
vmg12E1Ue (346), -- Gmux-2000 VMG (Media Gateway) E1 card with 12 external User ports
vmg12E1Ui (347), -- Gmux-2000 VMG (Media Gateway) E1 card with 12 internal User ports
vmg12T1Ue (348), -- Gmux-2000 VMG (Media Gateway) T1 card with 12 external User ports
vmg12T1Ui (349) -- Gmux-2000 VMG (Media Gateway) T1 card with 12 internal User ports
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the type of the card installed
in the specific slot position.
Only PS's are possible in the PS slots.
Only CL's are possible in the CL slots.
Only IO modules are possible in the IO slots.
Kmux card type start with the letter k.
LA card type start with the letters la."
::= { mdlSEntry 2}
mdlSHwVer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Hardware version of the
card installed in the specific slot position."
::= { mdlSEntry 3 }
mdlSSwVer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Software version of the
card installed in the specific slot position."
::= {mdlSEntry 4}
mdlSAlarmStatus OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
major (3),
minor (4),
event (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the current alarm state only for card level.
This object will be set to:
- critical(7): when there is at least one active (ON) critical
alarm .
- major (3): when there is no active critical alarm, but there is
at least one active (ON) major alarm .
- minor (4): when there is no active major or critical alarm, but
there is at least one active minor alarm.
- warning (6): when there is no active major, critical or minor alarm, but
there is at least one active warning alarm.
- event (5): when there is no active alarm of another type, but
there is at least one active event alarm.
- off(2): when there is no active (ON) alarm (since last clear operation)."
::= { mdlSEntry 5 }
mdlSAlarmStatusAll OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
major (3),
minor (4),
event (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the current card alarm state including the
lower level: card, port.
This object will be set to:
- critical(7): when there is at least one active (ON) critical
alarm .
- major (3): when there is no active critical alarm, but there is
at least one active (ON) major alarm .
- minor (4): when there is no active major or critical alarm, but
there is at least one active minor alarm.
- warning (6): when there is no active major, critical or minor alarm, but
there is at least one active warning alarm.
- event (5): when there is no active alarm of another type, but
there is at least one active event alarm.
- off(2): when there is no active (ON) alarm (since last clear operation)."
::= { mdlSEntry 6 }
mdlSTestStatus OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute will be on(3) when there is at least
one test running on a port of the module; otherwise the value
will be off(2)."
::= { mdlSEntry 7 }
mdlSHwStatus OBJECT-TYPE
SYNTAX INTEGER
{
fail(2),
ok (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute will be fail(2) when a HW FAIL exists
on this module (discovered by periodic self test);
otherwise the value will be ok(3)."
::= { mdlSEntry 8 }
mdlSActivity OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
offline (2),
online (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"notApplicable - when the slot is empty (no module)
offline(1) - when the module is not active (redundant)
online (2) - when the module is active ."
::= { mdlSEntry 9 }
mdlSAlrClearCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON, will enforce a clear
operation on the card level alarms . Upon completion,
the value will automatically change to off(2)."
::= { mdlSEntry 10 }
mdlSAlrClearAllCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON, will enforce a clear
operation on card and port level alarms . Upon completion,
the value will automatically change to off(2)."
::= { mdlSEntry 11 }
mdlSAlrMaskAll OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"on(3) - will cause masking of all the card level alarms.
These alarms will not be sent to NMS and will not
be taken into account for Alarms Status.
off(2) - will unmask all card level alarms except those
masked via the mdlAlrMaskTable. "
::= { mdlSEntry 12 }
mdlSCmd OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"General object for any special command at card level.
0=NotApplicable, for cards that don't support this object.
For KML.10(ISDN) card of KM-2100, the object will indicate
Manual Call Command in Switch mode. It is applicable only when
for KML.10, prtIsdnSwitchMode=manual.
KML.10 valid values:
'1' = noOp, will be used by agents that do not support this
feature or object (old KM agents)
'2' = off, Set call command mode to disconnect state. Disconnects the call.
'3' = on, Set call command mode to connect state. Connects the call.
For DXC IO cards, the object will be used for IO Card Reset HW command:
'2' = off, this will be always the Get value for these cards.
'3' = on, this is the Set command used to Reset the IO card. Upon
completing the operation, the value will automatically change to off(2),
by Agent.
For Slots that are NOT IO Slots and for empty IO Slots, the Get value will
be always '0' (NotApplicable). "
::= { mdlSEntry 13 }
mdlSReset OBJECT-TYPE
SYNTAX INTEGER {
off (2),
on (3) --HW
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset action to be performed on the module."
::= { mdlSEntry 14 }
mdlSRebuildFrame OBJECT-TYPE
SYNTAX INTEGER {notApplicable(1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Applicable only for KiloMux Main Link cards only.
'2' = off, this will be always the Get value.
'3' = on, this is the Set command used to Rebuild the Frame.
Upon completing the operation, the value will automatically change
to off(2), by Agent."
::= { mdlSEntry 15}
mdlSBackupSwVer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Backup Software version of the
card installed in the specific slot position."
::= {mdlSEntry 16}
mdlSSecondaryBackupSwVer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Secondary Backup Software version of the
card installed in the specific slot position."
::= {mdlSEntry 17}
mdlSPiggybackVer OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Piggyback version of the
card installed in the specific slot position."
::= { mdlSEntry 18 }
--General Card - Configuration table
--This table is NOT-APPLICABLE for a stand-alone unit
mdlCTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { mdlGen 2 }
mdlCEntry OBJECT-TYPE
SYNTAX MdlCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mdlCConfigIdx, mdlCSlotIdx }
::= { mdlCTable 1}
MdlCEntry ::=
SEQUENCE {
mdlCConfigIdx Integer32,
mdlCSlotIdx INTEGER,
mdlCProgCardType INTEGER,
mdlCNoOfExtPrt Integer32, -- RO
mdlCNoOfIntPrt Integer32, -- RO
mdlCParam Integer32
}
mdlCConfigIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Configuration number (1..255)
referred.
Value of 255 specifies the TmpCnfg (Scratch)."
::= { mdlCEntry 1}
-- In phase 1 only the values 1 (Cnfg1) and 255 (temp) are valid.
mdlCSlotIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
psC (20),
kmxPsA (101),
kmxPsB (102),
kmxMlA (103),
kmxMlB (104),
kmxCl (105),
kmxOpt (106),
kmxIO1 (107),
kmxIO2 (108),
kmxIO3 (109),
kmxIO4 (110),
kmxIO5 (111),
kmxIO6 (112),
kmxIO7 (113),
kmxIO8 (114),
kmxIO9 (115),
kmxIO10(116),
kmxIO11(117),
kmxIO12(118),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique number of the slot position
in which the module is inserted.
The Kilomux should use enumerated values starting with kmx."
::= { mdlCEntry 2}
mdlCProgCardType OBJECT-TYPE
SYNTAX INTEGER
{
--
-- General types
--
unknown (1),
empty (2),
-- Power Supply Modules
--
psAC (10),
psDC (11),
--
-- Cl Modules
--
gCl1 (18), -- IPmux1000 CL1
gCl2 (19), -- IPmux1000 CL2
dCl (20),
kCl (21),
dcl2 (22),
dcl2Eth (23),
kClEth (24),
dcl3 (25),
dcl3Eth (26),
--
-- T1/E1 Modules
--
d4T1 (28),
d8T1 (29),
dT1DSU (30),
dT1CSU (31),
dE1DSU (32),
dE1LTU (33),
dE1aDSU (34),
dE1aLTU (35),
dT1F (36),
dE1F (37),
d4E1 (38),
d8E1 (39),
--
-- xDSL Modules
dE1Hdsl (40), --Double Slot
dT1Hdsl (41), --Double Slot
dE1HdslS (42), --Single Slot
dT1HdslS (43), --Single Slot
d16gsdsl (44), --Single Slot, for DXC3000 only
d8sl (45), --Single Slot
d4slStuC (46), --Single Slot
d4slStuR (47), --Single Slot
-- KMUX Main Links
--
kML1 (50),
kML2 (51),
kML3 (52),
kML4 (53),
kML5 (54),
kML6 (55),
kML7 (56),
kML8 (57),
kML10 (59),
kMLF (60),
kML10New (61),
kML11RJ45 (62),
kML11FO (63),
--LS Modules
--
kLS1 (70),
kLS1New (71),
kLS2 (72),
--LAN Modules
--
kTRE (80),
kMBE (81),
kMBENew (82),
fLAN (83), -- FCD STM LAN moudle
--Optional Modules
--
kai (90),
kdi (91),
kdiCH (92),
-- HS Modules
--
dHS2 (100),
d8U (101),
d16U (102),
d4HS (103),
d8HS (104),
kHS1 (110),
kHS2 (111),
kHSU1 (112),
kHSU2 (113),
kHS703 (114),
-- Voice Modules
--
kVC1EM (130),
kVC1FXO (131),
kVC1FXS (132),
kVC1MEM (133),
kVC1MFXO (134),
kVC1MFXS (135),
kVC1MFXSW (136),
kVC2EM (137),
kVC2FXO (138),
kVC2FXS (139),
kVC2s1EM (140), --KVC2/1/E&M
kVC2s1FXO (141), --KVC2/1/FXO
kVC2s1FXS (142), --KVC2/1/FXS
kVC3EM (143),
kVC3FXO (144),
kVC3FXS (145),
kVC3S0 (146),
-- Fax Modules
--
kVF1EM (170),
kVF1FXO (171),
kVF1FXS (172),
kVF3EM (173),
kVF3FXO (174),
kVF3FXS (175),
kVF4EM (176),
kVF4FXO (177),
kVF4FXS (178),
kVF4FXSW (179),
kVF4S0 (180),
kVF5PbxE1 (181),
kVF5E1PbxSlave (182),
kVF5PbxT1 (183),
kVF5T1PbxSlave (184),
kVF5PbxE1New (185),
kVF5E1PbxSlaveNew (186),
kVF5PbxT1New (187),
kVF5T1PbxSlaveNew (188),
kVF4FXO3 (189),
kVF4FXS3 (190),
kVF4NS0 (191),
kVF6E1s16 (192), --KVF.6/E1/16
kVF6E1s31 (193), --KVF.6/E1/31
kVF6T1s12 (194), --KVF.6/T1/12
kVF6T1s24 (195), --KVF.6/T1/24
kVF8EM (196),
kVF8FXO (197),
kVF8FXS (198),
-- DIM Modules
--
dimETUR (200),
dimV35 (201),
dimRS422 (202),
dimRS530 (203),
dimHssi (204),
dimX21 (205),
dim10BaseT (206),
dimE1 (207),
dim100 (208),
--DACS T3/E3 Modules
--
dt3G747 (209),
dt3 (210),
dt3f (211),
de3 (212),
de3f (213),
-- STM-1 Modules
--
dstm1s1 (214), --DSTM1/1 Fractional
dstm1s2 (215), --DSTM1/2 Fractional + Redundancy
fstm1 (216), --FCD STM STM1 card
dstm1 (217), --DSTM1 Full
dstm1R (218), --DSTM1 Full + Redundancy
f2stm1 (219), -- FCD STM 2 STM1 ports card
gstm1 (220), -- IPmux1000 (GMUX) STM1 card
goc3 (221), -- IPmux1000 (GMUX) OC3 card
gstm1D (222), -- IPmux1000 (GMUX) STM1 card with 2 ports
goc3D (223), -- IPmux1000 (GMUX) OC3 card with 2 ports
-- The following numbers are used in mdlSCardType, for LA modules:
--
-- laSUB (230)
-- laVEM (231)
-- laVFXO (232)
-- laVFXS (233)
-- laV11 (234)
-- laV24 (235)
-- laV35 (236)
-- laT1 (237),
-- laT1Vxx (238),
-- laE1 (239),
-- laE1Vxx (240),
-- laISDN (241),
-- laVxx (242),
-- laEth (243),
-- laISDNwBU (244),
-- laIsdnNT (245), LA-140 ISDN NT
-- laIsdnNTwBU (246), LA-140 ISDN NT with backup (lifeline bottom connector)
-- laIsdnTE (247), LA-140 ISDN TE
-- laFXSwBU (248), LA-140 FXS with backup (lifeline bottom connector)
-- laFXSs (249), LA-140 bottom row FXS
-- laFXSwBUs (250), LA-140 bottom row FXS with backup (lifeline Top port)
-- laIsdnNTs (251), LA-140 bottom row ISDN NT
-- laIsdnNTwBUs (252), LA-140 bottom row ISDN NT with backup (lifeline Top port)
-- laIsdnTEs (253), LA-140 bottom row ISDN TE
-- laDp (254), LA-140 bottom single data port X21/V35/RS50
-- laSdsl (255), LA-140 top SDSL port
-- laSdslDp (256), LA-140 top SDSL port with bottom X21 or V35 Data Port
-- laAdslA (257), LA-140 bottom ADSLA port
-- laAdslADp (258), LA-140 bottom ADSLA port with top X21 or V35 Data Port
-- laAdslB (259), LA-140 bottom ADSLB port
-- laAdslBDp (260), LA-140 bottom ADSLB port with top X21 or V35 Data Port
-- laShdsl (261), LA-140 bottom SHDSL port
-- laShdslDp (262), LA-140 bottom SHDSL port with top X21 or V35 Data Port
-- laT1b (263), LA-140 bottom T1 port
-- laT1bDp (264), LA-140 bottom T1 port with top data port
-- laIsdnTEwBU (265), LA-140 ISDN TE with backup
-- laIsdnTEwBUs (266), LA-140 bottom row ISDN TE with backup
-- laShdsl4w (267), LA-140 bottom 4 wires SHDSL port
-- laShdsl4wDp (268), LA-140 bottom 4 wires SHDSL port with top Data Port
-- laEthSwitch (269) FCD-IPM
-- Server Modules
--
serverE1 (270), -- IPmux1000 (GMUX) Server E1 Card
serverT1 (271), -- IPmux1000 (GMUX) Server T1 Card
serverE1Pw (272), -- Gmux2000 Server E1 PW Card
serverT1Pw (273), -- Gmux2000 Server T1 PW Card
-- GiGabit ETH Modules
--
gigabitEth (280), -- Gmux2000 Gigabit ETH Card
gigabitEth2 (281), -- Gmux2000 new Gigabit ETH Card - 2 GbE ports with SFP connector
eth2 (282), -- Gmux2000 new ETH Card - 2 ETH ports with RJ45 connectors (10/100/1000)
gigabitEth8 (283), -- Gmux2000 new Gigabit ETH Card - 8 GbE ports with SFP connector
eth8 (284), -- Gmux2000 new ETH Card - 8 ETH ports with RJ45 connectors (10/100/1000)
-- CT3 Modules
--
channelizedT3Pw1 (290), -- Gmux2000 Channelized T3 PW Card
-- T1/E1 Modules
--
cesT128 (300), -- Gmux2000 CES T1 28 ports (external T1 ports) card.
cesE128 (301), -- Gmux2000 CES E1 28 ports (external E1 ports) card.
cesT1Pw28 (302), -- Gmux2000 CES T1 PW ports (external T1 ports) card.
cesE1Pw28 (303), -- Gmux2000 CES E1 PW ports (external E1 ports) card.
-- Vmux Modules
--
vmxE1VeDe (310), -- Gmux-2000 Vmux E1 card with external voice + external Data ports.
vmxE1VeDi (311), -- Gmux-2000 Vmux E1 card with external voice + internal Data ports.
vmxE1ViDe (312), -- Gmux-2000 Vmux E1 card with internal voice + external Data ports.
vmxE1ViDi (313), -- Gmux-2000 Vmux E1 card with internal voice + internal Data ports.
vmxT1VeDe (314), -- Gmux-2000 Vmux T1 card with external voice + external Data ports.
vmxT1VeDi (315), -- Gmux-2000 Vmux T1 card with external voice + internal Data ports.
vmxT1ViDe (316), -- Gmux-2000 Vmux T1 card with internal voice + external Data ports.
vmxT1ViDi (317), -- Gmux-2000 Vmux T1 card with internal voice + internal Data ports.
vc12E1UeNe (318), -- Gmux-2000 Vmux E1 card with 12 external User (voice) + 2 external Network (Data) ports.
vc12E1UeNi (319), -- Gmux-2000 Vmux E1 card with 12 external User (voice) + 2 internal Network (Data) ports.
vc12E1UiNe (320), -- Gmux-2000 Vmux E1 card with 12 internal User (voice) + 2 external Network (Data) ports.
vc12E1UiNi (321), -- Gmux-2000 Vmux E1 card with 12 internal User (voice) + 2 internal Network (Data) ports.
vc12T1UeNe (322), -- Gmux-2000 Vmux T1 card with 12 external User (voice) + 2 external Network (Data) ports.
vc12T1UeNi (323), -- Gmux-2000 Vmux T1 card with 12 external User (voice) + 2 internal Network (Data) ports.
vc12T1UiNe (324), -- Gmux-2000 Vmux T1 card with 12 internal User (voice) + 2 external Network (Data) ports.
vc12T1UiNi (325), -- Gmux-2000 Vmux T1 card with 12 internal User (voice) + 2 internal Network (Data) ports.
-- New Vmux Card Types
--
vca16E1UeNe (326), -- Gmux-2000 VCA E1 card with 16 external User (voice) + 2 external Network (Data) ports.
vca16E1UeNi (327), -- Gmux-2000 VCA E1 card with 16 external User (voice) + 2 internal Network (Data) ports.
vca16E1UiNe (328), -- Gmux-2000 VCA E1 card with 16 internal User (voice) + 2 external Network (Data) ports.
vca16E1UiNi (329), -- Gmux-2000 VCA E1 card with 16 internal User (voice) + 2 internal Network (Data) ports.
vca16T1UeNe (330), -- Gmux-2000 VCA T1 card with 16 external User (voice) + 2 external Network (Data) ports.
vca16T1UeNi (331), -- Gmux-2000 VCA T1 card with 16 external User (voice) + 2 internal Network (Data) ports.
vca16T1UiNe (332), -- Gmux-2000 VCA T1 card with 16 internal User (voice) + 2 external Network (Data) ports.
vca16T1UiNi (333), -- Gmux-2000 VCA T1 card with 16 internal User (voice) + 2 internal Network (Data) ports.
vca12E1UeNe (334), -- Gmux-2000 VCA E1 card with 12 external User (voice) + 2 external Network (Data) ports.
vca12E1UeNi (335), -- Gmux-2000 VCA E1 card with 12 external User (voice) + 2 internal Network (Data) ports.
vca12E1UiNe (336), -- Gmux-2000 VCA E1 card with 12 internal User (voice) + 2 external Network (Data) ports.
vca12E1UiNi (337), -- Gmux-2000 VCA E1 card with 12 internal User (voice) + 2 internal Network (Data) ports.
vca12T1UeNe (338), -- Gmux-2000 VCA T1 card with 12 external User (voice) + 2 external Network (Data) ports.
vca12T1UeNi (339), -- Gmux-2000 VCA T1 card with 12 external User (voice) + 2 internal Network (Data) ports.
vca12T1UiNe (340), -- Gmux-2000 VCA T1 card with 12 internal User (voice) + 2 external Network (Data) ports.
vca12T1UiNi (341), -- Gmux-2000 VCA T1 card with 12 internal User (voice) + 2 internal Network (Data) ports.
vmg16E1Ue (342), -- Gmux-2000 VMG (Media Gateway) E1 card with 16 external User ports
vmg16E1Ui (343), -- Gmux-2000 VMG (Media Gateway) E1 card with 16 internal User ports
vmg16T1Ue (344), -- Gmux-2000 VMG (Media Gateway) T1 card with 16 external User ports
vmg16T1Ui (345), -- Gmux-2000 VMG (Media Gateway) T1 card with 16 internal User ports
vmg12E1Ue (346), -- Gmux-2000 VMG (Media Gateway) E1 card with 12 external User ports
vmg12E1Ui (347), -- Gmux-2000 VMG (Media Gateway) E1 card with 12 internal User ports
vmg12T1Ue (348), -- Gmux-2000 VMG (Media Gateway) T1 card with 12 external User ports
vmg12T1Ui (349) -- Gmux-2000 VMG (Media Gateway) T1 card with 12 internal User ports
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the card type assigned to the specific
slot in the common configuration.
This object is identical for all the configurations (1..255).
Only the TmpCnf(255) might have a different value.
The write operation is valid only for the TmpCnfg entry."
::= { mdlCEntry 3}
mdlCNoOfExtPrt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of external ports in the programmed module of
the specific slot position"
::= { mdlCEntry 4}
mdlCNoOfIntPrt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of internal ports in the programmed module of
the specific slot position."
::= { mdlCEntry 5}
mdlCParam OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"General configuration object at card level (per configuration).
NotApplicable=0, for cards that don't support this object.
For D8U and D16U cards of DXC, the object will indicate
the port on which BERT will be performed. The port can be
one of the external ports, any of its associated B1, B2, D ports
or no port of the card (None=0).
For port indexes see DXC R6 spec.
For Gmux-2000, this parameter used for determining the Gigabit ETH exit port"
::= {mdlCEntry 6 }
--Module level current alarms
mdlAlr OBJECT IDENTIFIER ::= {mdlGen 3}
mdlAlrTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The list of card alarms. "
::= { mdlAlr 1 }
mdlAlrEntry OBJECT-TYPE
SYNTAX MdlAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {mdlAlrSltIdx , mdlAlrIdx}
::= { mdlAlrTable 1}
MdlAlrEntry ::=
SEQUENCE {
mdlAlrSltIdx INTEGER,
mdlAlrIdx Integer32,
mdlAlrCode Integer32,
mdlAlrState INTEGER, --severity
mdlAlarmMask INTEGER,
mdlAlarmInvert INTEGER,
mdlAlarmOnOff INTEGER,
mdlAlarmCounter Integer32
}
mdlAlrIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify an entry in the alarm status
table.
Users should use the get next function to read this table
because the indexes are not consecutive"
::= { mdlAlrEntry 1}
mdlAlrSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
psC (20),
kmxPsA (101),
kmxPsB (102),
kmxMlA (103),
kmxMlB (104),
kmxCl (105),
kmxOpt (106),
kmxIO1 (107),
kmxIO2 (108),
kmxIO3 (109),
kmxIO4 (110),
kmxIO5 (111),
kmxIO6 (112),
kmxIO7 (113),
kmxIO8 (114),
kmxIO9 (115),
kmxIO10(116),
kmxIO11(117),
kmxIO12(118)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the desired slot position.
The Kilomux should use enumerated values starting with kmx."
::= { mdlAlrEntry 2}
mdlAlrCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a code related to a specific
alarm description. The list of codes and their related
descriptions will be sent to NMS request (for display purpose)
by alrGenTable."
::= { mdlAlrEntry 3 }
mdlAlrState OBJECT-TYPE
SYNTAX INTEGER {
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the card alarm severity."
::= { mdlAlrEntry 4 }
mdlAlarmMask OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Mask is : on/off."
::= { mdlAlrEntry 5 }
mdlAlarmInvert OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Invert is : on/off."
::= { mdlAlrEntry 6 }
mdlAlarmOnOff OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm state is : on/off."
::= { mdlAlrEntry 7}
mdlAlarmCounter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A counter - how many times the alarm occured (ON) since last
clear operation or since last Reset."
::= { mdlAlrEntry 8 }
mdlAlrMaskTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlAlrMaskEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The list of card masked alarms. "
::= { mdlAlr 2 }
mdlAlrMaskEntry OBJECT-TYPE
SYNTAX MdlAlrMaskEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {mdlAlrMaskSltIdx}
::= { mdlAlrMaskTable 1}
MdlAlrMaskEntry ::=
SEQUENCE {
mdlAlrMaskSltIdx INTEGER,
mdlAlrMask OCTET STRING
}
mdlAlrMaskSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
psC (20),
kmxPsA (101),
kmxPsB (102),
kmxMlA (103),
kmxMlB (104),
kmxCl (105),
kmxOpt (106),
kmxIO1 (107),
kmxIO2 (108),
kmxIO3 (109),
kmxIO4 (110),
kmxIO5 (111),
kmxIO6 (112),
kmxIO7 (113),
kmxIO8 (114),
kmxIO9 (115),
kmxIO10(116),
kmxIO11(117),
kmxIO12(118)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the desired slot position.
The Kilomux should use enumerated values starting with kmx."
::= { mdlAlrMaskEntry 1}
mdlAlrMask OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (8..10))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is a mask that indicates which card level
alarms are masked. The masked alarms (their bit is set to
'1') are neither sent to the manager, nor taken into account
for alarm status and LEDs.
Bit no. = Alarm code
The bits that do not belong to the card level will be 0.
This object is applicable only when mdlSAlrMaskAll=off
(otherwise all card alarms are masked).
Example: When Alarm having the code 8 is masked,
the value of this object will be 100 (hex)."
::= { mdlAlrMaskEntry 2 }
--DACS dcl (Common Logic) card specific parameters
mdlClTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlClEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { mdlCl 1 }
mdlClEntry OBJECT-TYPE
SYNTAX MdlClEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mdlClIdx }
::= { mdlClTable 1}
MdlClEntry ::=
SEQUENCE {
mdlClIdx INTEGER,
mdlClSwchStatus Integer32,
mdlClLastFlipDate DisplayString,
mdlClLastFlipTime DisplayString,
mdlClLastFlipCause DisplayString
}
mdlClIdx OBJECT-TYPE
SYNTAX INTEGER {
clA (3),
clB (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Cl slot referred."
::= { mdlClEntry 1}
mdlClSwchStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the status of the switches on
the referred DCL card.
Each switch is represented by a bit. The status is a sum
of 2**n, according to the bits. There are 4 switches:
bit 0 SP-PAR (LSB) '1' - Default parameters
bit 1 PSWRD '1' - Password=default
'0' - Password=user selected
bit 2 DB-INIT '1' - DB initiated with default
'0' - DB initiated with NVRAM contents
bit 3 PC-SP (MSB) '1' - Management by terminal only
'0' - Management by NMS
Example: If SP-PAR and PSWRD bits are set ('1'), the value
will be 3 (2**1 + 2**0).
When the status of the switches is unknown, the value of
this object will be 255."
::= { mdlClEntry 2}
mdlClLastFlipDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Date when last flip occured.
The format would be as specified by the sysSDateFormat."
::= {mdlClEntry 3}
mdlClLastFlipTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time when last flip occured."
::= {mdlClEntry 4}
mdlClLastFlipCause OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The cause of last flip."
::= {mdlClEntry 5}
--DACS Ps (Power Supply) card specific parameters
mdlPsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlPsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { mdlPs 1 }
mdlPsEntry OBJECT-TYPE
SYNTAX MdlPsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mdlPsIdx }
::= { mdlPsTable 1}
MdlPsEntry ::=
SEQUENCE {
mdlPsIdx INTEGER,
mdlPsStatus INTEGER,
mdlPsTestResult INTEGER
}
mdlPsIdx OBJECT-TYPE
SYNTAX INTEGER {
psA (1),
psB (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the PS card referred."
::= { mdlPsEntry 1}
mdlPsStatus OBJECT-TYPE
SYNTAX INTEGER {
notActive (1),
active (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the status of the PS card."
::= { mdlPsEntry 2}
mdlPsTestResult OBJECT-TYPE
SYNTAX INTEGER {
ok (1),
f12V (2),
f5V (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the result of the PS card test.
ok (1) - the test passed successfully.
f12V (2) - 12V FAIL was detected
f5V (3) - 5V FAIL was detected."
::= { mdlPsEntry 3}
--Port level of DACS MIB
prtGen OBJECT IDENTIFIER ::= {prtDacsMux 1}
prtT1E1 OBJECT IDENTIFIER ::= {prtDacsMux 2}
prtHS OBJECT IDENTIFIER ::= {prtDacsMux 3}
prtSP OBJECT IDENTIFIER ::= {prtDacsMux 4}
prtDim OBJECT IDENTIFIER ::= {prtDacsMux 5}
prtI OBJECT IDENTIFIER ::= {prtDacsMux 6} --ISDN port
prtHdsl OBJECT IDENTIFIER ::= {prtDacsMux 7} --HDSL Line
prtT3E3 OBJECT IDENTIFIER ::= {prtDacsMux 8} --T3/E3 interface
--DACS port general parameters (common to all ports type except SP)
--The table contains both status and configuration information
prtGenParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtGenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { prtGen 1 }
prtGenEntry OBJECT-TYPE
SYNTAX PrtGenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtGenPrtIdx }
::= { prtGenParamTable 1}
PrtGenEntry ::=
SEQUENCE {
prtGenPrtIdx Integer32,
prtGenSlt INTEGER,
prtGenExtInt INTEGER,
prtGenIfIndex Integer32,
prtGenActiveStatus INTEGER,
prtGenAlrStatus INTEGER,
prtGenTestStatus INTEGER,
prtGenTestMask Integer32,
prtGenTestCmd Integer32,
prtGenTestRunning Integer32,
prtGenType INTEGER,
prtGenInterfaceType DisplayString,
prtGenAlrClearCmd INTEGER,
prtGenAlrMaskAll INTEGER,
prtGenParamStatus OCTET STRING,
prtGenRdnStatus INTEGER,
prtGenTestMaskXP OCTET STRING,
prtGenTestCmdXP OCTET STRING,
prtGenTestRunningXP OCTET STRING
}
prtGenPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify a port.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside/external, inside/internal.
In the Kilomux, the port index is calculated as follows:
100*Slot+Ch. The external Ch numbers are 1..10, and the
internal Ch numbers are 11..20.
In the DXC :
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card in odd or even numbers, as follows:
* For the outside/external ports, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
* The inside/internal ports, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 ."
::= { prtGenEntry 1}
prtGenSlt OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
kmxMlA (103),
kmxMlB (104),
kmxCl (105),
kmxOpt (106),
kmxIO1 (107),
kmxIO2 (108),
kmxIO3 (109),
kmxIO4 (110),
kmxIO5 (111),
kmxIO6 (112),
kmxIO7 (113),
kmxIO8 (114),
kmxIO9 (115),
kmxIO10(116),
kmxIO11(117),
kmxIO12(118),
standAlone (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify the slot where
the card is inserted in.
When the unit is stand-alone, this object is not applicable
and 255 will be used.
The Kilomux should use the enumerated starting with kmx."
::= { prtGenEntry 2}
prtGenExtInt OBJECT-TYPE
SYNTAX INTEGER
{
external (2),
internal (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the type of the designated port.
Exteral port is a port with a physical connector. Internal
port might be of two types, one is a composite port which
collects data of a few external ports into a common
bandwidth (usually routed trough DS1 link); the other type is
internal ports which get only part of external port data
(usually a few DS0's).
In the Kilomux-2100, the internal(3) value is used for
composite channels or sub-channels of an ISDN Ch."
::= { prtGenEntry 3}
prtGenIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the unique interface number
assigned to the port. The specific interface of this
attribute is the same as the interface identified by the
value of ifindex in MIB-II.If there is no interface for the
specific prtIdx, the value will be '7fffffff'h."
::= { prtGenEntry 4}
prtGenActiveStatus OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
notUsed (2),
offLine (3),
onLine (4),
offLineRedundancy (5),
onLineRedundancy (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the activity status of the port.
unknown(1) indicates that the information is not supported.
notUsed(2) indicates that the port is not connected according
to the active config.
offLine(3) indicates that the port is down (not working)
due to any problem.
onLine (4) indicates that the port is up (working)
offLineRedundancy(5) indicates that the port is down because
it is a redundant port.
onLineRedundancy (6) indicates that this is a redundant port
which is up and works as the active link."
::= { prtGenEntry 5}
prtGenAlrStatus OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
major (3),
minor (4),
event (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state at port (ch) agent level.
This object will be:
- critical(7): when there is at least one active (ON) critical
alarm .
- major (3): when there is no active critical alarm, but there is
at least one active (ON) major alarm .
- minor (4): when there is no active major or critical alarm, but
there is at least one active minor alarm.
- warning (6): when there is no active major, critical or minor alarm, but
there is at least one active warning alarm.
- event (5): when there is no active alarm of another type, but
there is at least one active event alarm.
- off(2): when there is no active (ON) alarm (since last clear operation)."
::= { prtGenEntry 6}
prtGenTestStatus OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute will be on(3) when there is at least one test
in progress (running) on the port; otherwise the value will
be off(2)."
::= { prtGenEntry 7}
prtGenTestMask OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a mask which indicates which tests from the
'prtGenTestCmd' list are allowed for the selected port.
If a specific test is allowed, its respective bit will be SET
in the mask :
TEST BIT
----------- ---
localLoop 1
remoteLoop 2
bert 3
plb 4
inband 5
prbs 8
loop2-v54 (RLB) 9
loop3-v54 (LLB) 10
Tone injection 13
Tx-plb 14
Tx-llb 15
DTE loop (HSSI) 16
HDSL-Tx-Inband 20
HDSL-Rx-Inband 21
Monitor 22 (test port)
User Line Loopback 23
Rem-Loop-on-Rem-Unit 25
LBBD 26
LB1 27
LB2 28
BERT-on-Rem-Unit 29
TS Remote Loop 30
LLB-on-Rem-Unit 31
e.g : If the return value is 3 -> 0000000000000011 ->
Bits 1 & 2 are set -> the allowed tests are :
local-loop
remote-loop "
::= { prtGenEntry 8}
prtGenTestCmd OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to a value as detailed furter on
(except 0) will initiate a test on the specific port,
if the operation is allowed (according to TestMask).
If the operation is not allowed, the mux will ignore the
operation.
The test/s requested will be set according to the respective
bit:
TEST BIT
----------- ---
localLoop 1
remoteLoop 2
bert 3
plb 4
inband 5
prbs 8
loop2-v54 (RLB) 9
loop3-v54 (LLB) 10
Tone injection 13
Tx-plb 14
Tx-llb 15
DTE loop (HSSI) 16
HDSL-Tx-Inband 20
HDSL-Rx-Inband 21
Monitor 22 (test port)
User Line Loopback 23
Rem-Loop-on-Rem-Unit 25
LBBD 26
LB1 27
LB2 28
BERT-on-Rem-Unit 29
TS Remote Loop 30
LLB-on-Rem-Unit 31
e.g : If the requested value is 3 -> 0000000000000011 ->
Bits 1 & 2 are set -> the requested tests are :
local-loop
remote-loop
Setting this object to stop (value=0 ; all bits are 0),
will stop all the user requested tests running on the
selected port; it will NOT stop the tests initiated by
the system."
::= { prtGenEntry 9}
prtGenTestRunning OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates which tests are running currently on
the selected port (initiated by user and/or by the system).
If a specific test is currently running on the port, its
respective bit will be SET:
TEST BIT
----------- ---
localLoop 1
remoteLoop 2
bert 3
plb 4
llb 5
txInband 6
rxInband 7
prbs 8
loop2-v54 (RLB) 9
loop3-v54 (LLB) 10
DDS DSU loop 11
DDS CSU loop 12
Tone injection 13
Tx-plb 14
Tx-llb 15
DTE loop (HSSI) 16
Local DTE loop (HSSI)17
Local Line loop (HSSI)18
Remote Line loop (HSSI)19
HDSL-Tx-Inband 20
HDSL-Rx-Inband 21
Monitor 22 (test port)
User Line Loopback 23
Network Line Loopback 24
Rem-Loop-on-Rem-Unit 25
LBBD 26
LB1 27
LB2 28
BERT-on-Rem-Unit 29
TS Remote Loop 30
LLB-on-Rem-Unit 31
e.g : If the return value is 3 -> 0000000000000011 ->
Bits 1 & 2 are set -> the running tests are :
local-loop
remote-loop
llb (Bit 5) - can be initiated by system only! "
::= { prtGenEntry 10}
prtGenType OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
t1 (2),
e1 (3),
hs (4),
t1Csu (5),
t1Dsu (6),
e1Ltu (7),
e1Dsu (8),
hdsl (9),
sp (10),
t1F (11), --T1 Fiber-optic
e1F (12), --E1 Fiber-optic
dim (13),
isdn (14),
t3 (15),
e3 (16),
t3f (17),
e3f (18),
idsl (19),
stm1 (20),
vc4 (21),
vc12 (22),
msdsl (23),
vc11 (24),
vc3 (25),
soh (26),
eth (27),
shdsl (28),
other (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes the type of the selected port.
idsl - applicable for external ports of HS-U cards (of DXC) when
interface is LT-1."
::= { prtGenEntry 11}
prtGenInterfaceType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique HW interface type of the
selected port.
Examples:
- for T1 cards: DSU, CSU
- for E1 cards: DSU, LTU
- for HS cards: v35, rs422, x21
etc..."
::= { prtGenEntry 12}
prtGenAlrClearCmd OBJECT-TYPE
SYNTAX INTEGER
{
noOp (1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON, will enforce a clear
operation on the port level alarms . Upon completion,
the value will automatically change to off(2).
noOp - will be used by agents that do not support this
feature or object."
::= { prtGenEntry 13 }
prtGenAlrMaskAll OBJECT-TYPE
SYNTAX INTEGER
{
noOp (1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"on(3) - will mask all the alarms of the selected port
off(2)- will unmask all alarms of the selected port except
the ones selected by the prtAlrMaskTable.
noOp - will be used by agents that do not support this
feature or object."
::= { prtGenEntry 14 }
prtGenParamStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates Status of parameters specific to the
selected port.
- For a port that has no special status or is supported
by prtSExHsfStatTable - 1 Octet: 00hex
- For HS cards (Dxc cards) - 1 octet:
Bit 7 (MSB)..Bit 2 = 0 (NA)
Bit 0 and 1 indicates RTS control signal state:
Bit 1: '1'=active ; '0'=notActive
Bit 0 (LSB): '1'=unknown ; '0'=NA
- For HS-U/1 external port (MP card, used in FCD-M) - 1 Octet:
Bit 7 6 5 4 3 2 1 0 LSB
|________| |__| |__|
spare modem sync
modem: 00 = other sync: 00 = not sync
01 = unknown 01 = sync
10 = ASMi-31/2 10 = reserved
11 = reserved 11 = reserved
- For VC-6, VC-12, VC-12/6 external ports - 1 Octet :
Bit 7 (MSB)..Bit 2 = 0 (NA)
Bit 1: Tx Signaling '1'=On ; '0'=Off
Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off
- For VC-2/R2(FXS) external ports - 1 Octet :
Bit - 7 6 5 4 3 2 1 0
|_| |_________|
Call Call State
Direction
Bit 7 (MSB) and Bit 6 : Call Direction
00 - Incoming
01 - Outgoing
Bit 5..Bit 0: Call State
000000 - Idle
000001 - Seized
000010 - Both-Way Conflict
000011 - Seizure Ack
000100 - Answered
000101 - Clear Backward
000110 - Clear Forward
000111 - Blocked
001000 - Fault
001001 - Fault 3
001010 - Fault 4
001011 - Fault 5
001100 - Fault 6
001101 - Fault 7
- For ML-20 external port - 3 Octets :
- 1 MS Octet will represent the Real Rate used:
Bit - 7 6 5 4 3 2 1 0
|___| |_______|
spare Rate
Valid values: 0..31, meaning 0..31x64Kbps
Invalid values: 32..255.
- 2 LS Octets will represent the Status of 7 Control
Signals:
Signal - --- CTS DSR DCD RJ TM DTR RTS
Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Octet - 2 3 (LS)
'---' will always have the value 00
Rest of the Signals (2 bits each) can have the following
values:
00=NA ; 01=Unused ; 10=Off ; 11=On
- For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet
Bit - 7 6 5 4 3 2 1 0
|___________|
spare Mode of Operation
Mode of Operation: '1'=Central ; '0'=Remote
- For KM2100, KVF.5 cards - indicates the status of A and B signaling
for each internal channel.
1 Octet:
Bit - 7 6 5 4 3 2 1 0
|_____| |_| |_|
spare B A
Bit 0 (LSB) and Bit 1 : A status
Bit 2 and Bit 3 : B status
00 - Off
01 - On
11 - Unknown
- For FCD-W, NETWORK and USER ports - 1 Octet
Status of Control Signals: '1'=On ; '0'=Off or when not applicable
Bit - 7 6 5 4 3 2 1 0
Bit 7 (MSB) - Signal Loss (applicable only for G.703 interface)
Bit 6 - CONTROL (applicable only for X.21 interface)
Bit 5 - INDICATION (applicable only for X.21 interface)
Bit 4 - DSR (applicable only for V.35 interface)
Bit 3 - RTS (applicable only for V.35 interface)
Bit 2 - CTS (applicable only for V.35 interface)
Bit 1 - DTR (applicable only for V.35 interface)
Bit 0 - DCD (applicable only for V.35 interface)
- For DXC R6 , D8U, D16U External ports - 1 Octet
Bit 7 6 5 4 3 2 1 0 LSB
|________| |__| |__|
spare modem sync
modem: 00 = other sync: 00 = not sync
01 = unknown 01 = sync
10 = ASMi-31/2 10 = reserved
11 = reserved 11 = reserved
- For DXC DE1-HDSL, DT1-HDSL, D16GSDSL, D8SL External ports - 2 Octets
MSB octet: far-end modem channel interface
LSB octet: Sub Link existence (Y/N), far-end modem type,
synchronization with far-end modem
MSB octet: 0000 0000 = no interface
0000 0001 = db15 (X21)
0000 0010 = IR-IP
0000 0011 = IR-ETH-Q
0000 0100 = V35
0000 0101 = ETH-RJ45
0000 0110 = G703
0000 0111 = db25 (RS530)
0000 1000 = ETH-BNC
0000 1001 = E1(Balanced)
0000 1010 = E1(Unbalanced)
0000 1011 = IR-ETH-QN
Rest of the combinations: reserved
LSB octet:
Bit 7 6 5 4 3 2 1 0 LSB
| |___________| |__|
SL modem sync
or Box material
SL: modem: 00000 = other sync: 00 = not sync
0=not exist 00001 = unknown 01 = sync
1=exists 00010 = ASMi-31/2 10 = reserved
00011 = HCD-E1 11 = reserved
Box material 00100 = HTU-E1
(for D8SL card): 00101 = HTU-2
0=metal 00110 = ASMi-52 SA/2W/Slave
1=plastic 00111 = ASMi-52 SA/2W/Master
01000 = ASMi-52/CQ card of LRS-24
01001 = ASMi-52/CD card of LRS-24
01010 = D16GSDSL card of DXC-3000
01011 = LRS-52
01100 = FCD
01110 = D8GSDSL card of DXC-3000
01111 = ASMi-52A
Rest = reserved "
::= { prtGenEntry 15}
prtGenRdnStatus OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
off (2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates if this port is part of a redundant pair and in
this case, if it is On or Off.
none(1) - No redundancy or Not Applicable
off (2) - the port is part of a redundant pair and it is Off from
Redundancy point of view (not the port used).
on (3) - the port is part of a redundant pair and it is On from
Redundancy point of view (it is the port used)."
::= { prtGenEntry 16 }
prtGenTestMaskXP OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is an Expanded test mask of the prtGenTestMask object.
The prtGenTestMask object reached its maximum, being an Integer with 31 bits.
This object indicates which tests from the 'prtGenTestCmdXP' list are
allowed for the selected port.
If a specific test is allowed, its respective bit will be SET
in the mask :
TEST BIT
----------- ---
localLoop 1 =LSB
remoteLoop 2
bert 3
plb 4
inband 5
prbs 8
loop2-v54 (RLB) 9
loop3-v54 (LLB) 10
Tone injection 13
Tx-plb 14
Tx-llb 15
DTE loop (HSSI) 16
HDSL-Tx-Inband 20
HDSL-Rx-Inband 21
Monitor 22 (test port)
User Line Loopback 23
Rem-Loop-on-Rem-Unit 25
LBBD 26
LB1 27
LB2 28
BERT-on-Rem-Unit 29
TS Remote Loop 30
LLB-on-Rem-Unit 31
Downstream-AIS 32
Upstream-AIS 33
Send-RDI 34
Test Per TS 35
e.g : If the return value is 00000003 hex ->
Bits 1 & 2 are set -> the allowed tests are :
local-loop
remote-loop "
::= { prtGenEntry 17}
prtGenTestCmdXP OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is an Expanded test command of the prtGenTestCmd object.
The prtGenTestCmd object reached its maximum, being an Integer with 31 bits.
Setting this object to a value as detailed furter on
(except 0) will initiate a test on the specific port,
if the operation is allowed (according to TestMaskXP).
If the operation is not allowed, the mux will ignore the
operation.
The test/s requested will be set according to the respective
bit:
TEST BIT
----------- ---
localLoop 1 =LSB
remoteLoop 2
bert 3
plb 4
inband 5
prbs 8
loop2-v54 (RLB) 9
loop3-v54 (LLB) 10
Tone injection 13
Tx-plb 14
Tx-llb 15
DTE loop (HSSI) 16
HDSL-Tx-Inband 20
HDSL-Rx-Inband 21
Monitor 22 (test port)
User Line Loopback 23
Rem-Loop-on-Rem-Unit 25
LBBD 26
LB1 27
LB2 28
BERT-on-Rem-Unit 29
TS Remote Loop 30
LLB-on-Rem-Unit 31
Downstream-AIS 32
Upstream-AIS 33
Send-RDI 34
Test Per TS 35
e.g : If the requested value is 00000003 hex ->
Bits 1 & 2 are set -> the requested tests are :
local-loop
remote-loop
Setting this object to stop (value=0 ; all bits are 0),
will stop all the user requested tests running on the
selected port; it will NOT stop the tests initiated by
the system."
::= { prtGenEntry 18}
prtGenTestRunningXP OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is an Expanded object of the prtGenTestRunning object.
The prtGenTestRunning object reached its maximum, being an Integer with 31 bits.
This object indicates which tests are running currently on
the selected port (initiated by user and/or by the system).
If a specific test is currently running on the port, its
respective bit will be SET:
TEST BIT
----------- ---
localLoop 1 =LSB
remoteLoop 2
bert 3
plb 4
llb 5
txInband 6
rxInband 7
prbs 8
loop2-v54 (RLB) 9
loop3-v54 (LLB) 10
DDS DSU loop 11
DDS CSU loop 12
Tone injection 13
Tx-plb 14
Tx-llb 15
DTE loop (HSSI) 16
Local DTE loop (HSSI)17
Local Line loop (HSSI)18
Remote Line loop (HSSI)19
HDSL-Tx-Inband 20
HDSL-Rx-Inband 21
Monitor 22 (test port)
User Line Loopback 23
Network Line Loopback 24
Rem-Loop-on-Rem-Unit 25
LBBD 26
LB1 27
LB2 28
BERT-on-Rem-Unit 29
TS Remote Loop 30
LLB-on-Rem-Unit 31
Downstream-AIS 32
Upstream-AIS 33
Send-RDI 34
Test Per TS 35
e.g : If the return value is 00000003 hex ->
Bits 1 & 2 are set -> the running tests are :
local-loop
remote-loop
llb (Bit 5) - can be initiated by system only! "
::= { prtGenEntry 19}
--prtGenTestDuration - Setting Duration of tests
prtGenTestDurationTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtGenTestDurationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { prtGen 2 }
prtGenTestDurationEntry OBJECT-TYPE
SYNTAX PrtGenTestDurationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtGenTestPrtIdx, prtGenTestIdx }
::= { prtGenTestDurationTable 1}
PrtGenTestDurationEntry ::=
SEQUENCE {
prtGenTestPrtIdx Integer32,
prtGenTestIdx INTEGER,
prtGenTestDuration Integer32
}
prtGenTestPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify a port.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside/external, inside/internal.
In the Kilomux, the port index is calculated as follows:
100*Slot+Ch. The external Ch numbers are 1..10, and the
internal Ch numbers are 11..20.
In the DXC :
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card in odd or even numbers, as follows:
* For the outside/external ports, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
* The inside/internal ports, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 ."
::= { prtGenTestDurationEntry 1}
prtGenTestIdx OBJECT-TYPE
SYNTAX INTEGER
{
localLoop (1),
remoteLoop (2),
bert (3),
plb (4),
rlb (5),
llb (6),
toneInjection (7),
txInband (8),
rxInband (9),
remLoopOnRemUnit (10),
bertOnRemUnit (11),
llbOnRemUnit (12),
txPlb (14),
txLlb (15),
dteLoop (16), --HSSI
hdslTxInband (20),
hdslRxInband (21),
monitor (22),
userLineLoopback(23),
lbbd (26),
lb1 (27),
lb2 (28),
tsRemoteLoop (30),
downstreamAis(32),
upstreamAis (33),
sendRdi (34)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the test, the duration refers. "
::= { prtGenTestDurationEntry 2}
prtGenTestDuration OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the maximum duration of executing
a test on the specific port. This entry applies to the
specified test . The resolution will be a minute, and the
maximum duration is limited to 30 minutes .
A zero value specifies no time limitation.
When the test isn't active the agent initiates this object to
2 min. when the duration is needed and to 0 if it's not
required."
::= { prtGenTestDurationEntry 3}
--prtGen TS (TimeSlot) Assignment Table - for all ports of IO cards
prtGenTsTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtGenTsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table's Objects is valid only
for the TmpCnfg entry (Scratch),exept some products
which enable direct writing to the ActiveCnfg.
This is written in the respective product's spec. "
::= { prtGen 3}
prtGenTsEntry OBJECT-TYPE
SYNTAX PrtGenTsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtGenTsCnfgIdx, prtGenTsPrtIdx, prtGenTsIdx }
::= { prtGenTsTable 1}
PrtGenTsEntry ::=
SEQUENCE {
prtGenTsCnfgIdx Integer32,
prtGenTsPrtIdx Integer32,
prtGenTsIdx Integer32,
prtGenTsType INTEGER,
prtGenTsIConPrt Integer32,
prtGenTsIConTs Integer32
}
prtGenTsCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg(1..255) being
accessed.
Idx of 255 relates to the TmpCnfg. "
::= { prtGenTsEntry 1}
prtGenTsPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside,
SP.
In the DXC :
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card in odd or even numbers, as follows:
* For the outside/external ports, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
* The inside/internal ports, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 ."
::= { prtGenTsEntry 2}
prtGenTsIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique time slot position.
The valid time slots are
1..25 for T1 Card (25=Fbit)
0..31 for E1 or HS Card .
In G732S-E1 lines time slot 16 is not valid for data,
it is dedicated for multiframe synchronization bits
and voice signaling."
::= { prtGenTsEntry 3}
prtGenTsType OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
voice (2),
data (3),
vcMP (4),
nc (5),
mng (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of Timeslot.
If the source or destination port is an HS port,'TS Type'
must be 'data'.
nc - means that this TimeSlot is not connected.
voice, data, vcMP - also mean that this TS is connected.
mng - means that this TS is dedicated to Management (not
connected to another port."
::= { prtGenTsEntry 4}
prtGenTsIConPrt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the internally (In Mux)
connected port.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside,
SP.
* The outside ports will be the T1/E1 cards ports.
The convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
for a stand-alone unit, the IO slot will be considered 1.
- last one/two digits will be the port number within the
card, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
* The inside ports will be for example, the HS cards ports.
The convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
for a stand-alone unit, the IO slot will be considered 1.
- last one/two digits will be the port number within the
card, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 .
* noConnection - will be indicated as 10 for DXC and FCD-E1/T1.
- will be indicated as 100 for FCD-E1/I and SMODs.
* Split TS (same TS is Split to several ports) - 11.
* notApplicable- will be indicated as 100 for LRS IMODs.
All HS port's timeslots must have the same destination
port."
::= {prtGenTsEntry 5}
prtGenTsIConTs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique time slot position.
The valid time slots are
1..25 for T1 Card (25=Fbit)
0..31 for E1 (or HS) Card.
In G732S-E1 lines time slot 16 is not valid for data, it is
dedicated for multiframe synchronization bits and voice
signaling.
* For DXC: All HS port's timeslots must start with Timeslot
no.1 "
::= {prtGenTsEntry 6}
--Port current alarms table
prtAlr OBJECT IDENTIFIER ::= {prtGen 4}
prtSAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { prtAlr 1 }
prtSAlarmEntry OBJECT-TYPE
SYNTAX PrtSAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtSAlarmPrtIdx, prtSAlarmIdx}
::= { prtSAlarmTable 1}
PrtSAlarmEntry ::=
SEQUENCE {
prtSAlarmPrtIdx Integer32,
prtSAlarmIdx Integer32,
prtSAlarmCode Integer32,
prtSAlarmState INTEGER, --severity
prtSAlarmMask INTEGER,
prtSAlarmInvert INTEGER,
prtSAlarmOnOff INTEGER,
prtSAlarmCounter Integer32
}
prtSAlarmIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify an entry in the alarm status
table.
Users should use the get next function to read this table
because the indexes are not consecutive."
::= { prtSAlarmEntry 1}
prtSAlarmPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify a port.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside/external, inside/internal.
In the Kilomux, the port index is calculated as follows:
100*Slot+Ch. The external Ch numbers are 1..10, and the
internal Ch numbers are 11..20.
In the DXC :
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card in odd or even numbers, as follows:
* For the outside/external ports, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
* The inside/internal ports, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 ."
::= { prtSAlarmEntry 2}
prtSAlarmCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a code related to a specific
alarm description. The list of codes and their related
descriptions will be sent to NMS request (for display purpose)
by alrGenTable."
::= { prtSAlarmEntry 3 }
prtSAlarmState OBJECT-TYPE
SYNTAX INTEGER {
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the port alarm severity."
::= { prtSAlarmEntry 4 }
prtSAlarmMask OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Mask is : on/off."
::= { prtSAlarmEntry 5 }
prtSAlarmInvert OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Invert is : on/off."
::= { prtSAlarmEntry 6 }
prtSAlarmOnOff OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm state is : on/off."
::= { prtSAlarmEntry 7 }
prtSAlarmCounter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A counter - how many times the alarm occured (ON) since last
clear operation or since last Reset."
::= { prtSAlarmEntry 8 }
prtAlrMaskTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtAlrMaskEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { prtAlr 2 }
prtAlrMaskEntry OBJECT-TYPE
SYNTAX PrtAlrMaskEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtAlrMaskPrtIdx}
::= { prtAlrMaskTable 1}
PrtAlrMaskEntry ::=
SEQUENCE {
prtAlrMaskPrtIdx Integer32,
prtAlrMask OCTET STRING
}
prtAlrMaskPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify a port.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside/external, inside/internal.
In the Kilomux, the port index is calculated as follows:
100*Slot+Ch. The external Ch numbers are 1..10, and the
internal Ch numbers are 11..20.
In the DXC :
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card in odd or even numbers, as follows:
* For the outside/external ports, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
* The inside/internal ports, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 ."
::= { prtAlrMaskEntry 1}
prtAlrMask OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (8))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is a mask that indicates which port level
alarms are masked. The masked alarms (their bit is set to
'1') are neither sent to the manager, nor taken into account
for alarm status and LEDs.
Bit no. = Alarm code
The bits that do not belong to the port level will be 0.
This object is applicable only when prtGenAlrMaskAll=off
(otherwise all port alarms are masked).
Example: When Alarms having the codes 31 and 40 are masked,
the value of this object will be 10080000000 (hex)."
::= { prtAlrMaskEntry 2 }
--Port BERT table
prtBertTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtBertEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes the BERT parameters, counters and
commands.
The configurable parameters:
- prtBertPattern
- prtBertInjectRate
- prtBertTs
are not Set per configuration (same for all Configurations)
but start being applied by the Agent only upon successful
Update/Download operation. Therefore, Set will enter the
values to the Temporary Configuration of the agent, while
Get will get the values of the Active Configuration."
::= { prtGen 5 }
prtBertEntry OBJECT-TYPE
SYNTAX PrtBertEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtBertPrtIdx}
::= { prtBertTable 1}
PrtBertEntry ::=
SEQUENCE {
prtBertPrtIdx Integer32,
prtBertPattern INTEGER,
prtBertInjectRate INTEGER,
prtBertInjectErrRateCmd INTEGER,
prtBertInjectSingleErrCmd INTEGER,
prtBertRunTime Integer32,
prtBertESs Integer32,
prtBertSyncLoss Integer32,
prtBertErrorBits Integer32,
prtBertClearCounters INTEGER,
prtBertSyncStatus INTEGER,
prtBertTs OCTET STRING,
prtBertResult DisplayString,
prtBertTxBits Integer32,
prtBertRxBits Integer32,
prtBertTxErrorBits Integer32
}
prtBertPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify a port.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside/external, inside/internal.
In the Kilomux, the port index is calculated as follows:
100*Slot+Ch. The external Ch numbers are 1..10, and the
internal Ch numbers are 11..20.
In the DXC :
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card in odd or even numbers, as follows:
* For the outside/external ports, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
* The inside/internal ports, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 .
In the MP :
- first two digits will be: (IO slot number+10)
- last one/two digits will be according to the external port
number within the card:
exPrt1 -> 1
exPrt2 -> 3
exPrt3 -> 5
exPrt4 -> 7 . "
::= { prtBertEntry 1}
prtBertPattern OBJECT-TYPE
SYNTAX INTEGER
{
p2E3m1 (1),
p2E4m1 (2),
p2E5m1 (3),
p2E6m1 (4),
p2E7m1 (5),
p511 (6),
p2E10m1 (7),
p2047 (8),
p2E15m1 (9),
p2E17m1 (10),
p2E18m1 (11),
p2E20m1 (12),
qrss (13),
p2E21m1 (14),
p2E22m1 (15),
p2E23m1 (16),
p2E25m1 (17),
p2E28m1 (18),
p2E29m1 (19),
p2E31m1 (20),
p2E32m1 (21),
rj011 (22),
p63 (23),
p1M7S (24),
p1S7M (25),
alternate(26),
mark (27),
space (28),
p2E11m1 (29),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the pattern of the BERT.
p2Exxm1 = 2Exx-1.
pxx = pattern xx.
This object is the same for all configurations.
notApplicable - when this object is not supported."
::= { prtBertEntry 2}
prtBertInjectRate OBJECT-TYPE
SYNTAX INTEGER
{
noError (1),
r10Em1 (2),
r10Em2 (3),
r10Em3 (4),
r10Em4 (5),
r10Em5 (6),
r10Em6 (7),
r10Em7 (8),
single (9),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the error rate injection of the BERT.
r10Emx = 10E-x
This object is the same for all configurations.
single - single error injection.
notApplicable - when this object is not supported."
::= { prtBertEntry 3}
prtBertInjectErrRateCmd OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls activation/deactivation of the Error
Rate Injection during BERT."
::= { prtBertEntry 4}
prtBertInjectSingleErrCmd OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables to initiate a Single Error Injection
during BERT (on). Upon completion, the value will
automatically change to off(2)."
::= { prtBertEntry 5}
prtBertRunTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates how much time (seconds) passed since
BERT started to run."
::= { prtBertEntry 6}
prtBertESs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"How many Errored Seconds were detected since BERT started
to run.
Counter for Kmux and MP."
::= { prtBertEntry 7}
prtBertSyncLoss OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"How many times Sync Loss was detected since BERT started
to run.
For some products: number of seconds in which Sync Loss occured
since BERT started to run. See product specification."
::= { prtBertEntry 8}
prtBertErrorBits OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"How many Error Bits were detected since BERT started
to run."
::= { prtBertEntry 9}
prtBertClearCounters OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to ON, will enforce a clear
operation of some BERT Counters. Upon completion,
the value will automatically change to off(2)."
::= { prtBertEntry 10}
prtBertSyncStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
syncLoss (2),
sync (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sync Status while BERT runs."
::= { prtBertEntry 11}
prtBertTs OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates on which TSs of the selected port, BERT
should be applied.
Each Bit of the Octet represents a TS:
31 ......0
MSB LSB
Bit 0 will not be used.
If the bit value is '1' - BERT should be applied on this TS.
For a T1 port, the valid raised bits ('1') are: 1..25.
For an E1 port, the valid raised bits ('1') are: 1..31.
Agents that do not support this feature will send SIZE 0."
::= { prtBertEntry 12}
prtBertResult OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates Result of BERT
for the selected port
(number of error bits divided to the total
number of data bits.)
Applicable only if BERT is running on this port
Agents that do not support this feature will send SIZE 0."
::= { prtBertEntry 13}
prtBertTxBits OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"How many data bits were transmitted since BERT started
to run, or since last counter clear
(prtBertClearCounters set to on)."
::= { prtBertEntry 14}
prtBertRxBits OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"How many data bits were Received since BERT started
to run, or since last counter clear
(prtBertClearCounters set to on)."
::= { prtBertEntry 15}
prtBertTxErrorBits OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of injected error bits since BERT started
to run, or since last counter clear
(prtBertClearCounters set to on)."
::= { prtBertEntry 16}
--Port Monitoring Table - for Monitoring ports
--The table is applicable only for DXC T1/E1/HS ports and Optimux-T3
prtMonTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtMonEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For DXC, the write operation into the Table's Objects is valid only
for the TmpCnfg entry (Scratch)."
::= { prtGen 6}
prtMonEntry OBJECT-TYPE
SYNTAX PrtMonEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtMonCnfgIdx, prtMonitoringIdx }
::= { prtMonTable 1}
PrtMonEntry ::=
SEQUENCE {
prtMonCnfgIdx Integer32,
prtMonitoringIdx Integer32,
prtMonitoringEnable INTEGER,
prtMonitoringTSs OCTET STRING,
prtMonitoredPort Integer32,
prtMonitoredTSs OCTET STRING
}
prtMonCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg(1..255) being
accessed.
Idx of 255 relates to the TmpCnfg.
For products that do not support configurations, 1 will be always used."
::= { prtMonEntry 1}
prtMonitoringIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Monitoring Port Index.
For DXC:
The valid port number depends on the IO slot no., the
installed card type and the port type: external, internal.
* The external ports will according to the convention (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
* The internal ports will be according to the convention (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 .
For Optimux-T3:
255 (Not Applicable) will be always used. The Monitoring port is always
the Station Clock (not considered an interface)."
::= { prtMonEntry 2}
prtMonitoringEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if the prtMonitoringIdx is configured as
a monitoring port or not.
disabled = the port is NOT configured to monitor. Setting this object
to this value will cause reset (to 0) of the prtMonitoringTSs
and prtMonitoredTSs objects.
enabled = the port IS configured to monitor.
For Optimux-T3: always enabled (RO supported)."
::= {prtMonEntry 3}
prtMonitoringTSs OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates which TSs of the Monitoring port,
the test equipment should monitor.
Each Bit of the Octet represents a TS:
31 ......0
MSB LSB
Bit 0 will not be used.
If the bit value is '1' - this TS should be monitored.
For a T1 port, the valid raised bits ('1') are: 1..24.
For an E1 port, the valid raised bits ('1') are: 1..31.
Default: all bits='0'
Agents that do not support this feature will send SIZE 0.
This object can be Set as described only if prtMonitoringEnable=enabled. "
::= {prtMonEntry 4}
prtMonitoredPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the MONITORED Port Index that the Monitoring
port monitors.
For DXC:
The valid port number depends on the IO slot no., the
installed card type and the port type: external, internal.
* The external ports will according to the convention (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
* The internal ports will be according to the convention (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 .
* 100 - no port monitored
For Optimux-T3:
The valid channels are:
0 = no Ch monitored
1..21 or 1..28 (=CH1..CH21 or CH1..CH28) according to product's
configuration."
::= { prtMonEntry 5}
prtMonitoredTSs OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates which TSs of the Monitored port, should be monitored.
Each Bit of the Octet represents a TS:
31 ......0
MSB LSB
Bit 0 will not be used.
If the bit value is '1' - this TS should be monitored.
For a T1 port, the valid raised bits ('1') are: 1..24.
For an E1 port, the valid raised bits ('1') are: 1..31.
Default: all bits='0'
Agents that do not support this feature will send SIZE 0.
This object can be Set as described only if prtMonitoringEnable=enabled."
::= {prtMonEntry 6}
-- Port Configuration Table
-- This table is applicable for KMUX, FCD-T1/E1 , FCD-T1L/E1L and FCD-U ports
prtCfgParam OBJECT IDENTIFIER ::= {prtGen 7}
prtCfgParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtCfgParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry.
KMUX parameters are for the cards: KMBE/New, KVF.6 family."
::= { prtCfgParam 1}
prtCfgParamEntry OBJECT-TYPE
SYNTAX PrtCfgParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtCfgParamCnfgIdx, prtCfgParamIdx }
::= { prtCfgParamTable 1}
PrtCfgParamEntry ::=
SEQUENCE {
prtCfgParamCnfgIdx Integer32,
prtCfgParamIdx Integer32,
prtCfgParamSlt INTEGER,
prtCfgParamOperatedMl INTEGER,
prtCfgParamMlAtoMlBPrio INTEGER,
prtCfgParamMlBtoMlAPrio INTEGER,
prtCfgParamInbandLoopDetection INTEGER,
prtCfgParamInbandLoopPatternCfg INTEGER,
prtCfgParamInbandLoopActPattern DisplayString,
prtCfgParamInbandLoopDeactPattern DisplayString
}
prtCfgParamCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg."
::= {prtCfgParamEntry 1}
prtCfgParamIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port (within the card when applicable).
- For KM-2100: Slot*100+Ch
external ports: Ch=1..10
internal ports (sub-channels): Ch=11..20.
- For FCD-T1/E1(L): MAIN=111, SUB=113, CH1=122, CH2=124.
- For other devices, see specific device's spec. "
::= {prtCfgParamEntry 2}
prtCfgParamSlt OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
kmxIO1 (107),
kmxIO2 (108),
kmxIO3 (109),
kmxIO4 (110),
kmxIO5 (111),
kmxIO6 (112),
kmxIO7 (113),
kmxIO8 (114),
kmxIO9 (115),
kmxIO10(116),
kmxIO11(117),
kmxIO12(118),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify the slot where
the card is inserted in.
In the 2104 Unit the entries kmxIO5(111)..kmxIO12(118) are not valid.
notApplicable(255) - for products that do not have Slots."
::= {prtCfgParamEntry 3}
prtCfgParamOperatedMl OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
kmxMlA (103),
kmxMlB (104)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The main link for this channel.
The field is relevant only for ML modes of Dual, Priority
Bumping and Switched Backup."
::= {prtCfgParamEntry 4}
prtCfgParamMlAtoMlBPrio OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
low (2),
high (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ML-A to ML-B Priority.
The field is relevant only for ML modes of Priority Bumping
and Switched Backup."
::= {prtCfgParamEntry 5}
prtCfgParamMlBtoMlAPrio OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
low (2),
high (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ML-B to ML-A Priority.
The field is relevant only for ML modes of Priority Bumping."
::= {prtCfgParamEntry 6}
prtCfgParamInbandLoopDetection OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Inband Loop Detection.
The field is relevant for FCD-T1/E1(L) ports."
::= {prtCfgParamEntry 7}
prtCfgParamInbandLoopPatternCfg OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
rdlLoop (2),
userConfig (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if Inband Loop polynomial pattern
will be according to RDL Loop (the standard) or User Configurated
according to prtCfgParamInbandLoopActPattern and
prtCfgParamInbandLoopDeactPattern."
::= {prtCfgParamEntry 8}
prtCfgParamInbandLoopActPattern OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is a binary string of up to 8 bits.
Though the syntax allows for any ASCII characters, for this object
only '0' or '1' characters are valid.
The string determines coefficients of the polynomial pattern
sent to the port in order to Activate the Inband Loop.
This object is relevant only when prtCfgParamInbandLoopPatternCfg=userConfig."
::= {prtCfgParamEntry 9}
prtCfgParamInbandLoopDeactPattern OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is a binary string of up to 8 bits.
Though the syntax allows for any ASCII characters, for this object
only '0' or '1' characters are valid.
The string determines coefficients of the polynomial pattern
sent to the port in order to Deactivate the Inband Loop.
This object is relevant only when prtCfgParamInbandLoopPatternCfg=userConfig."
::= {prtCfgParamEntry 10}
--DACS T1/E1 port specific parameters
--DACS T1/E1 port statistics parameters.
--These parameters are in addition to those of RFC-1406 MIB.
prtT1E1StatTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtT1E1StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"T1/E1 port statistics table."
::= { prtT1E1 1}
prtT1E1StatEntry OBJECT-TYPE
SYNTAX PrtT1E1StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry in the T1/E1 port statistics table."
INDEX { prtT1E1SPrtIdx }
::= { prtT1E1StatTable 1}
PrtT1E1StatEntry ::=
SEQUENCE {
prtT1E1SPrtIdx Integer32,
prtT1E1SSlt INTEGER,
prtT1E1OosCount Gauge32,
prtT1E1BpvLastMin Gauge32,
prtT1E1BpvMax Gauge32
}
prtT1E1SPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
The same numbering as for prtGenPrtIdx.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside.
* The outside ports will be the T1/E1 cards ports.
The convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 ."
::= { prtT1E1StatEntry 1}
prtT1E1SSlt OBJECT-TYPE
SYNTAX INTEGER
{
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
standAlone (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify the slot where
the card is inserted in.
When the unit is stand-alone, this object is not applicable
and 255 will be used."
::= { prtT1E1StatEntry 2}
prtT1E1OosCount OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is applicable only for an E1 active port.
It provides the number of red alarm events since the last
count clearing."
::= { prtT1E1StatEntry 3 }
prtT1E1BpvLastMin OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is applicable only for an E1 active port.
It provides the number of BPV (BiPolar Violation) events
detected during the last minute."
::= { prtT1E1StatEntry 4 }
prtT1E1BpvMax OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is applicable only for an E1 active port.
It provides the maximal number of BPV (BiPolar Violation)
events (per minute), detected during the worst minute."
::= { prtT1E1StatEntry 5 }
--DACS T1/E1 port configuration parameters.
--
--Objects 2..9 appear in RFC-1406 MIB (dsx1ConfigTable) as RW
--objects. They were entered in this private MIB, because in
--RFC-1406 MIB there is no reference to configuration number.
prtT1E1CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtT1E1CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"T1/E1 port configuration table."
::= { prtT1E1 2}
prtT1E1CnfgEntry OBJECT-TYPE
SYNTAX PrtT1E1CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry in the T1/E1 port configuration table."
INDEX { prtT1E1CnfgIdx, prtT1E1PrtIdx }
::= { prtT1E1CnfgTable 1}
PrtT1E1CnfgEntry ::=
SEQUENCE {
prtT1E1CnfgIdx Integer32,
prtT1E1PrtIdx Integer32,
prtT1E1Slt INTEGER,
prtT1E1LineType INTEGER,
prtT1E1LineCode INTEGER,
prtT1E1SignalMode INTEGER,
prtT1E1Fdl INTEGER,
prtT1E1FdlMode INTEGER,
prtT1E1Sync INTEGER,
prtT1E1CGA INTEGER,
prtT1E1IdleCode OCTET STRING,
prtT1E1OosSignal INTEGER,
prtT1E1VoiceOos OCTET STRING,
prtT1E1DataOos OCTET STRING,
prtT1E1LineLengthMask INTEGER,
prtT1E1TxGainMask INTEGER,
prtT1E1InbandMng INTEGER,
prtT1E1InbandMngRate INTEGER,
prtT1E1DedicatedTs Integer32,
prtT1E1InbandMngRoutProt INTEGER,
prtT1E1LinkMode INTEGER,
prtT1E1Multiplier INTEGER,
prtT1E1RxGain INTEGER,
prtT1E1RAI INTEGER,
prtT1E1LineMode INTEGER,
prtT1E1TS0SaBits OCTET STRING,
prtT1E1ConnectedTS INTEGER,
prtT1E1Ts0SaBit INTEGER,
prtT1E1SameFeCnfg INTEGER,
prtT1E1RemCrc4 INTEGER,
prtT1E1MaxTSs Integer32,
prtT1E1EocTsConfig INTEGER,
prtT1E1Role INTEGER,
prtT1E1PppEchoFailDetection INTEGER
}
prtT1E1CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config. "
::= { prtT1E1CnfgEntry 1}
prtT1E1PrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
The same numbering as for prtGenPrtIdx.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside.
In the DXC :
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card in odd or even numbers, as follows:
* For the outside/external ports, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
* The inside/internal ports, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 .
In the Kilomux, the port index is calculated as follows:
100*Slot+Ch. The external Ch numbers are 1..10, and the
internal Ch numbers are 11..20."
::= { prtT1E1CnfgEntry 2}
prtT1E1Slt OBJECT-TYPE
SYNTAX INTEGER
{
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
kmxMlA (103),
kmxMlB (104),
kmxOpt (106),
kmxIO1 (107),
kmxIO2 (108),
kmxIO3 (109),
kmxIO4 (110),
kmxIO5 (111),
kmxIO6 (112),
kmxIO7 (113),
kmxIO8 (114),
kmxIO9 (115),
kmxIO10(116),
kmxIO11(117),
kmxIO12(118),
standAlone (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify the slot where
the card is inserted in.
When the unit is stand-alone, this object is not applicable
and 255 will be used."
::= { prtT1E1CnfgEntry 3}
prtT1E1LineType OBJECT-TYPE
SYNTAX INTEGER {
other (1),
esf (2),
d4 (3), --sf
e1 (4),
e1Crc (5),
e1MF (6),
e1CrcMF (7),
unframed (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates the variety of T1/E1
Line implementing this circuit. The type of
circuit affects the number of bits per second
that the circuit can reasonably carry, as well
as the interpretation of the usage and error
statistics. The values, in sequence, describe:
TITLE: SPECIFICATION:
esf Extended SuperFrame DS1
d4 AT&T D4 format DS1 - SF
e1 CCITT Recommendation G.704
(Table 4a) - G732N
e1Crc CCITT Recommendation G.704
(Table 4b) - G732N with CRC
e1MF G.704 (Table 4a) with TS16
multiframing enabled - G732S
e1CrcMF G.704 (Table 4b) with TS16
multiframing enabled - G732S with CRC
unframed
T1 - applicable values: (1),(2),(3),(8)
E1 - applicable values: (1),(4),(5),(6),(7),(8) "
::= { prtT1E1CnfgEntry 4 }
prtT1E1LineCode OBJECT-TYPE
SYNTAX INTEGER {
jbzs (1),
b8zs (2),
hdb3 (3),
zbtsi(4),
ami (5),
other(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable describes the variety of Zero
Code Suppression used on the link, which in
turn affects a number of its characteristics.
jbzs=b7zs refers the Jammed Bit Zero Suppres-
sion, in which the AT&T specification of at
least one pulse every 8 bit periods is literal-
ly implemented by forcing a pulse in bit 8 of
each channel. Thus, only seven bits per chan-
nel, or 1.344 Mbps, is available for data (used for T1).
b8zs refers to the use of a specified pattern
of normal bits and bipolar violations
which are used to replace a sequence of eight
zero bits (used for T1).
ANSI Clear Channels may use zbtsi, or Zero
Byte Time Slot Interchange.
E1 links, with or without CRC, use hdb3 or
ami (= TRAN).
amI (=TRAN) refers to a mode wherein no zero code
suppression is present and the line encoding
does not solve the problem directly. In this
application, the higher layer must provide data
which meets or exceeds the pulse density re-
quirements, such as inverting HDLC data."
::= { prtT1E1CnfgEntry 5 }
prtT1E1SignalMode OBJECT-TYPE
SYNTAX INTEGER {
none (1),
robbedBit (2),
bitOriented (3), --CAS
messageOriented (4) --CCS
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"'none' indicates that no bits are reserved for
signaling on this channel.
'robbedBit' indicates that T1 Robbed Bit Signaling is in use.
'bitOriented' indicates that E1 Channel Associated
Signaling (CAS) is in use.
'messageOriented' indicates that Common Channel Signaling
(CCS) is in use either on channel 16 of an E1 link or
channel 24 of a T1."
::= { prtT1E1CnfgEntry 6 }
prtT1E1Fdl OBJECT-TYPE
SYNTAX INTEGER {
other (1),
ansi-T1-403(2),
att-54016 (4),
fdl-none (8),
transFdl (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This bitmap describes the use of the facili-
ties data link, and is the sum of the capabili-
ties:
'other' indicates that a protocol other than
one following is used.
'ansi-T1-403' refers to the FDL exchange
recommended by ANSI.
'att-54016' refers to ESF FDL exchanges.
'fdl-none' indicates that the device does
not use the FDL.
'transFdl' indicates transition between two ports of
the same card. "
::= { prtT1E1CnfgEntry 7 }
prtT1E1FdlMode OBJECT-TYPE
SYNTAX INTEGER {
other (1),
user (2),
carrier (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Fdl Mode of the T1 selected port.
notApplicable - will be used for an E1 port."
::= { prtT1E1CnfgEntry 8 }
prtT1E1Sync OBJECT-TYPE
SYNTAX INTEGER {
other (1),
tr62411(2),
ccitt (3),
fast (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables returning to normal operation, after
the end of a main/sub link red alarm event, in reduced time.
'tr62411' - complies with AT&T TR-62411 (after 10 seconds).
Applicable for both T1 and E1 interfaces.
'ccitt' - complies with CCITT standard. Applicable only
for E1 interfaces.
'fast' - after 1 second."
::= { prtT1E1CnfgEntry 9 }
prtT1E1CGA OBJECT-TYPE
SYNTAX INTEGER {
none (1),
trans(2),
full (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object selects the method used to signal the CGA state
to the other end, through the main/sub link.
'none' - non-transparent mode. When one of the links
(main/sub) will be in Out Of Service state, both
'Data/Voice Oos' and 'Oos Signal' will be
transmitted to the other end.
'trans' - when one of the links (main/sub) will be in Out
Of Service state, 'Data/Voice Oos' will be
transmitted to the other end.
'full' - fully-transparent mode. When one of the links
(main/sub) will be in Out Of Service state,
neither 'Data/Voice Oos' nor 'Oos Signal' will
be transmitted to the other end."
::= { prtT1E1CnfgEntry 10 }
prtT1E1IdleCode OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object selects the code transmitted to fill idle
(unused) time slots in the main link frame.
Valid range: (0 - FF HEX) ."
::= { prtT1E1CnfgEntry 11 }
prtT1E1OosSignal OBJECT-TYPE
SYNTAX INTEGER
{
notsupported (2),
forcedIdle (3),
forcedBusy (4),
busyIdle (5),
idleBusy (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"'idle' = '0' = on-hook, idle state
'busy' = '1' = off-hook, busy state
'forcedIdle' = SP = both A and B signaling bits are forced
to '0' during out-of-service periods.
'forcedBusy' = MK = both A and B signaling bits are forced
to '1' during out-of-service periods.
'busyIdle' = MK_SP = A and B bits are forced to '1' for
2.5 seconds; then they are switched to '0'
until out-of-service condition disappears.
'idleBusy' = SP_MK = A and B bits are forced to '0' for
2.5 seconds; then they are switched to '1'
until out-of-service condition disappears.
- for T1: '0'=0 ; '1'=1
- for E1: '0'=1 ; '1'=0 "
::= { prtT1E1CnfgEntry 12 }
prtT1E1VoiceOos OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Voice Out-Of-Service code. Valid range: (0 - FF HEX).
For agents that do not support this feature, the value will
always be 0."
::= { prtT1E1CnfgEntry 13 }
prtT1E1DataOos OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data Out-Of-Service code. Valid range: (0 - FF HEX).
For agents that do not support this feature, the value will
always be 0."
::= { prtT1E1CnfgEntry 14 }
prtT1E1LineLengthMask OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
len0p133ft (2),
len134p266ft (3),
len267p399ft (4),
len400p533ft (5),
len534p655ft (6),
fcc68 (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the line length mask parameter used only
for T1/DSU interfaces.
len400p533ft=length range: 400ft to 533ft
'fcc68' - provides compliance with the FCC 68.308 Option A
output pulse mask. "
::= { prtT1E1CnfgEntry 15 }
prtT1E1TxGainMask OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
txGain0db (2),
txGain7dot5db (3),
txGain15db (4),
txGain22dot5db (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the tx gain mask parameter (dB), used
only for T1/CSU interfaces."
::= { prtT1E1CnfgEntry 16 }
prtT1E1InbandMng OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
fdlOrTs0 (3),
dedicatedTs (4),
dedicatedPpp(5),
dedicatedFr (6),
internal (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique number to identify an Inband management over the
link.
internal - supported by KM-2100 only. It means that the management is internal
to the frame. It takes part of the ML Frame bits (instead of data)."
::= {prtT1E1CnfgEntry 17}
prtT1E1InbandMngRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
r4k (2),
r8k (3),
r12k (4),
r16k (5),
r32k (6),
r64k (7),
r20k (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique number to identify the rate of the Inband management.
It is required only for E1 links and is applicable only when
prtExT1E1InbandMng selected is FdlOrTs0 or dedicatedTs."
::= {prtT1E1CnfgEntry 18}
prtT1E1DedicatedTs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value is differently determined for different products.
There are two methods:
1) A unique number to identify Dedicated TS of the T1/E1 port.
It is applicable only when prtExT1E1InbandMng selected is
dedicatedTs.
1..24 - Dedicated TS of T1
1..31 - Dedicated TS of E1
255 - notApplicable (for agents that do not support this
feature)
Other values are invalid.
2) For FCD-STM, up to five TSs may be dedicated to management.
This object value is the Sum (sigma) of 2**n, where n =TS-1
e.g. Time slots 3,5,7,9,11 are dedicated to management:
2** 2
+2** 4
+2** 6
+2** 8
+2**10 = 4+16+64+256+1024=1364
User should consult the product specification, to find out
the method employed."
::= {prtT1E1CnfgEntry 19}
prtT1E1InbandMngRoutProt OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
proprietary (3),
rip2 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Inband Mng Routing Protocol of the port.
When prtT1E1InbandMng is 'dedicatedPpp'-'proprietary' and
'rip2' are applicable.
For other values - only 'proprietary' is applicable.
For FCD-M and FCD-A:
When prtT1E1InbandMng is 'dedicatedPpp' or 'dedicatedFr':
'None', 'proprietary' and 'rip2' are applicable.
When prtT1E1InbandMng is 'fdlOrTS0' or 'dedicatedTs':
'None' and 'proprietary' are applicable.
When prtT1E1InbandMng is 'off':
'None' is applicable."
::= {prtT1E1CnfgEntry 20}
prtT1E1LinkMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
regular (2),
transparent (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"regular - TSs are connected by user via TS Assignment only
transparent - when a port with this Link Mode is connected to an
internal T1/E1 port of a T3/E3 card, TS0, TS16 and Fbit
are transparently transferred to the E3/T3 stream."
::= {prtT1E1CnfgEntry 21}
prtT1E1Multiplier OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
br56 (2),
br64 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The data rate of each TS. The multiplier values
can be 56 kbps or 64 kbps. For T1 only."
::= { prtT1E1CnfgEntry 22 }
prtT1E1RxGain OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
rxGain12dB (2),
rxGain30dB (3),
rxGain36dB (4),
shortHaul (5),
longHaul (6),
rxGain20dB (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the rx volume (dB)."
::= { prtT1E1CnfgEntry 23 }
prtT1E1RAI OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Remote Alarm Signal"
::= { prtT1E1CnfgEntry 24 }
prtT1E1LineMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
csu (2),
dsu (3),
ltu (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Interface type of the port.
For T1 - csu, dsu are the valid values
For E1 - dsu, ltu are the valid values"
::= { prtT1E1CnfgEntry 25 }
prtT1E1TS0SaBits OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only for E1 ports. For T1, string size will be 0.
For E1, it enables user to select the use of TS0 Sa Bits 4..8, by 3 octets:
The order (in hexa display):
free Sa-Bit-4 Sa-Bit-5 Sa-Bit-6 Sa-Bit-7 Sa-Bit-8
|___________| |________________| |________________|
MSByte LSByte
Each Sa Bit will be represented by a nibble, having the following meaning:
0000 = zero
0001 = one
0010 = management
0011 = transparent
the rest are reserved for future use."
::= { prtT1E1CnfgEntry 26 }
prtT1E1ConnectedTS OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates if there is any connected TS for this interface."
::= { prtT1E1CnfgEntry 27 }
prtT1E1Ts0SaBit OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
noMng (2),
mng (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates whether to send TS 0, or not.
noMng= TS 0 is looped, therefore not sent.
mng= TS 0 isn't looped, therefore it is sent."
::= { prtT1E1CnfgEntry 28 }
prtT1E1SameFeCnfg OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates whether the same E1 configuration
parameters and TS assignment are set both to the local
and remote device.
Read-Write access is applicable only in G732N framed mode.
For G732S and UNFRAMED this parameter is set by
agent to YES and is Read Only.
In Case of conflict during power-up between the central
and remote, the value set by the central unit is the valid one."
::= { prtT1E1CnfgEntry 29 }
prtT1E1RemCrc4 OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the E1 of the Remote device
connected to this E1 port, will have CRC-4 or not."
::= { prtT1E1CnfgEntry 30 }
prtT1E1MaxTSs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only for DXC D4T1, D4E1, D8T1, D8E1
external ports and D8GSL internal E1 ports.
It is relevant only when sysCIntTsAllocMode=static(2).
255=not applicable
If prtT1E1LineType=unframed(8), the value of this object must be 32.
Else, the valid values are 0..31."
::= { prtT1E1CnfgEntry 31}
prtT1E1EocTsConfig OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the use of EOC for TS Configuration
is enabled or not."
::= { prtT1E1CnfgEntry 32 }
prtT1E1Role OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
sub (2),
main (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether this port behaves as SUB or Main link."
::= { prtT1E1CnfgEntry 33 }
prtT1E1PppEchoFailDetection OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the PPP Echo is taken into account
for its Fail Detection.
This object is relevant when Inband Mng between devices is Dedicated TS PPP.
Default=Disable.
Enable - will be selected mainly when a T1/E1 Ring exists and between 2 adjacent
Ring devices there is another device or Net, that causes these Ring devices
not to sense that the PPP connection between them is lost. In this case,
Echo Request should be initiated by the port."
::= { prtT1E1CnfgEntry 34 }
--prtT1E1 Last FDL Message Table - Statistics
prtT1E1FdlMsgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtT1E1FdlMsgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is applicable for a T1 interface with 'esf'
LineType or E1 interface, when CRC is enabled (LineType)."
::= { prtT1E1 3}
prtT1E1FdlMsgEntry OBJECT-TYPE
SYNTAX PrtT1E1FdlMsgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtT1E1FdlMsgPrtIdx, prtT1E1FdlMsgFdlType}
::= { prtT1E1FdlMsgTable 1}
PrtT1E1FdlMsgEntry ::=
SEQUENCE {
prtT1E1FdlMsgPrtIdx Integer32,
prtT1E1FdlMsgFdlType INTEGER,
prtT1E1FdlMsgSlt INTEGER,
prtT1E1FdlMsg OCTET STRING
}
prtT1E1FdlMsgPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
The same numbering as for prtGenPrtIdx.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside.
* The outside ports will be the T1/E1 cards ports.
The convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 ."
::= { prtT1E1FdlMsgEntry 1}
prtT1E1FdlMsgFdlType OBJECT-TYPE
SYNTAX INTEGER
{
send (1),
receive (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Fdl type reference of the Fdl message."
::= { prtT1E1FdlMsgEntry 2}
prtT1E1FdlMsgSlt OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
standAlone (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify the slot where
the card is inserted in.
When the unit is stand-alone, this object is not applicable
and 255 will be used."
::= { prtT1E1FdlMsgEntry 3}
prtT1E1FdlMsg OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"FDL message."
::= { prtT1E1FdlMsgEntry 4}
--prtHS specific parameters (configuration & status) table
prtHSParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtHSParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { prtHS 1 }
prtHSParamEntry OBJECT-TYPE
SYNTAX PrtHSParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtHSCnfgIdx, prtHSPrtIdx }
::= { prtHSParamTable 1}
PrtHSParamEntry ::=
SEQUENCE {
prtHSCnfgIdx Integer32,
prtHSPrtIdx Integer32,
prtHSSlt INTEGER,
prtHSRate INTEGER,
prtHSFifoSize INTEGER,
prtHSClkMode INTEGER,
prtHSCTS INTEGER,
prtHSRtsState INTEGER,
prtHSInbandLoopback INTEGER,
prtHSInbandLoopPatternCfg INTEGER,
prtHSInbandLoopActPattern DisplayString,
prtHSInbandLoopDeactPattern DisplayString,
prtHSDCD INTEGER,
prtHSClkPolarity INTEGER,
prtHSInterfaceType INTEGER,
prtHSUnframed INTEGER
}
prtHSCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config. "
::= { prtHSParamEntry 1}
prtHSPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify a port.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside,
SP.
* The inside ports will be the HS cards ports. The
convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 ."
::= { prtHSParamEntry 2}
prtHSSlt OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
standAlone (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify the slot where
the card is inserted in.
When the unit is stand-alone, this object is not applicable
and 255 will be used."
::= { prtHSParamEntry 3}
prtHSRate OBJECT-TYPE
SYNTAX INTEGER {
r0x56eq0Kbps (1),
r1x56eq56Kbps (2),
r2x56eq112Kbps (3),
r3x56eq168Kbps (4),
r4x56eq224Kbps (5),
r5x56eq280Kbps (6),
r6x56eq336Kbps (7),
r7x56eq392Kbps (8),
r8x56eq448Kbps (9),
r9x56eq504Kbps (10),
r10x56eq560Kbps (11),
r11x56eq616Kbps (12),
r12x56eq672Kbps (13),
r13x56eq728Kbps (14),
r14x56eq784Kbps (15),
r15x56eq840Kbps (16),
r16x56eq896Kbps (17),
r17x56eq952Kbps (18),
r18x56eq1008Kbps(19),
r19x56eq1064Kbps(20),
r20x56eq1120Kbps(21),
r21x56eq1176Kbps(22),
r22x56eq1232Kbps(23),
r23x56eq1288Kbps(24),
r24x56eq1344Kbps(25),
r25x56eq1400Kbps(26),
r26x56eq1456Kbps(27),
r27x56eq1512Kbps(28),
r28x56eq1568Kbps(29),
r29x56eq1624Kbps(30),
r30x56eq1680Kbps(31),
r31x56eq1736Kbps(32),
r0x64eq0Kbps (33),
r1x64eq64Kbps (34),
r2x64eq128Kbps (35),
r3x64eq192Kbps (36),
r4x64eq256Kbps (37),
r5x64eq320Kbps (38),
r6x64eq384Kbps (39),
r7x64eq448Kbps (40),
r8x64eq512Kbps (41),
r9x64eq576Kbps (42),
r10x64eq640Kbps (43),
r11x64eq704Kbps (44),
r12x64eq768Kbps (45),
r13x64eq832Kbps (46),
r14x64eq896Kbps (47),
r15x64eq960Kbps (48),
r16x64eq1024Kbps(49),
r17x64eq1088Kbps(50),
r18x64eq1152Kbps(51),
r19x64eq1216Kbps(52),
r20x64eq1280Kbps(53),
r21x64eq1344Kbps(54),
r22x64eq1408Kbps(55),
r23x64eq1472Kbps(56),
r24x64eq1536Kbps(57),
r25x64eq1600Kbps(58),
r26x64eq1664Kbps(59),
r27x64eq1728Kbps(60),
r28x64eq1792Kbps(61),
r29x64eq1856Kbps(62),
r30x64eq1920Kbps(63),
r31x64eq1984Kbps(64),
r32x64eq2048Kbps(65),
r32x56eq1792Kbps(66),
r64x64eq4096Kbps(67),
auto (200)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the port rate (speed).
auto - rate is selected automatically by system."
::= { prtHSParamEntry 4}
prtHSFifoSize OBJECT-TYPE
SYNTAX INTEGER {
auto (1),
b32bit (2),
b60bit (3),
b104bit (4),
b144bit (5),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object selects the size of the user data channel buffer
FIFO used in the DTE2 mode. In the other modes, buffer
size is automatically set by the DACS agent.
Buffer FIFO size in bits, corresponds to FIFO lengths of
+/-16, +/-30, +/-52, +/-72 bits."
::= { prtHSParamEntry 5}
prtHSClkMode OBJECT-TYPE
SYNTAX INTEGER {
dce (1),
dte1 (2),
dte2 (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock Mode of the user data channel.
dce - DACS operates as a DCE and provides transmit
and receive clocks to the synchronous user DTE.
dte1- DACS supplies the receive clock to the user
equipment and accepts the user transmit clock.
dte2- DACS requires transmit and receive clocks from
the user equipment."
::= { prtHSParamEntry 6}
prtHSCTS OBJECT-TYPE
SYNTAX INTEGER {
on (1),
rts (2),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selection of CTS line state in the user data channel.
on - CTS continuously ON.
rts - CTS line follows the RTS line."
::= { prtHSParamEntry 7}
prtHSRtsState OBJECT-TYPE
SYNTAX INTEGER {
off (2),
on (3),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"RTS state of the port."
::= { prtHSParamEntry 8}
prtHSInbandLoopback OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if Inband Loopback from the Network
should be enabled or disabled."
::= {prtHSParamEntry 9}
prtHSInbandLoopPatternCfg OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
rdlLoop (2),
userConfig (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if Inband Loop polynomial pattern
will be according to RDL Loop (the standard) or User Configurated
according to prtHSActivatePolyPattern and prtHSDeactivatePolyPattern."
::= {prtHSParamEntry 10}
prtHSInbandLoopActPattern OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is a binary string of up to 8 bits.
Though the syntax allows for any ASCII characters, for this object
only '0' or '1' characters are valid.
The string determines coefficients of the polynomial pattern
sent to the port in order to Activate the Inband Loop.
This object is relevant only when prtHSInbandLoopPatternCfg=userConfig."
::= {prtHSParamEntry 11}
prtHSInbandLoopDeactPattern OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is a binary string of up to 8 bits.
Though the syntax allows for any ASCII characters, for this object
only '0' or '1' characters are valid.
The string determines coefficients of the polynomial pattern
sent to the port in order to Deactivate the Inband Loop.
This object is relevant only when prtHSInbandLoopPatternCfg=userConfig."
::= {prtHSParamEntry 12}
prtHSDCD OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
linkOK (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selection of DCD line state in the user data channel.
linkOK - DCD line is ON only when active link is OK.
on - DCD continuously ON."
::= { prtHSParamEntry 13}
prtHSClkPolarity OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
normal (2),
invert (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the clock polarity."
::= {prtHSParamEntry 14}
prtHSInterfaceType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
rs530 (2), --EIA 530
v35 (3),
rs422 (4),
x21 (5),
v24 (6),
rs530a (7), --EIA 530A
rs232 (8),
rs449 (9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the selected electrical interface type."
::= {prtHSParamEntry 15}
prtHSUnframed OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Unframed line for HS ports.
yes - means that all TSs must be transferred, including TS0.
In this case, prtHSRate must be r31x56eq1736Kbps OR
r31x64eq1984Kbps."
::= { prtHSParamEntry 16}
prtHSBertTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtHSBertEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { prtHS 2 }
prtHSBertEntry OBJECT-TYPE
SYNTAX PrtHSBertEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtHSBertPrtIdx }
::= { prtHSBertTable 1}
PrtHSBertEntry ::=
SEQUENCE {
prtHSBertPrtIdx Integer32,
prtHSBertSlt INTEGER,
prtHSBertCountClr INTEGER,
prtHSBertTestResult Integer32
}
prtHSBertPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify a port.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside,
SP.
* The inside ports will be the HS cards ports. The
convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 ."
::= { prtHSBertEntry 1}
prtHSBertSlt OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
standAlone (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify the slot where
the card is inserted in.
When the unit is stand-alone, this object is not applicable
and 255 will be used."
::= { prtHSBertEntry 2}
prtHSBertCountClr OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object (to on) initiate bert counter clear
operation.
Valid only when bert test is active on the specific port.
(Every time a new bert test starts, the counter is
automatically cleared; this command enables clearing
the counter while the test is running)."
::= { prtHSBertEntry 3}
prtHSBertTestResult OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of Bit Error Rate indicated
during the BERT test.
Active only when bert test is running on the selected port."
::= { prtHSBertEntry 4}
--prt SP specific configuration parameters
prtSpCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSpCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= {prtSP 1}
prtSpCnfgEntry OBJECT-TYPE
SYNTAX PrtSpCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"All the entries at this table are identical(have the same value)
at all the configurations(1..255) except at the TmpCnfg.
- For products supporting more than one configuration, the write operation
into the Table Objects is valid only at the TmpCnfg entry.
- For products that do not support configurations, the write operation
into the Table Objects will be to prtSpCnfgIdx=1."
INDEX {prtSpCnfgIdx, prtSpPrtIdx }
::= { prtSpCnfgTable 1}
PrtSpCnfgEntry ::=
SEQUENCE {
prtSpCnfgIdx Integer32,
prtSpPrtIdx Integer32,
prtSpUsage INTEGER,
prtSpRate INTEGER,
prtSpDataBits INTEGER,
prtSpParity INTEGER,
prtSpCallOutMode INTEGER,
prtSpInterface INTEGER,
prtSpCTS INTEGER,
prtSpDcdDelay INTEGER,
prtSpDsr INTEGER,
prtSpNoOfRetries Integer32,
prtSpWaitForConnect INTEGER,
prtSpDialMode INTEGER,
prtSpAltNumMode INTEGER,
prtSpPrimaryNum DisplayString,
prtSpAltNum DisplayString,
prtSpRoutProtocol INTEGER,
prtSpCmd OCTET STRING,
prtSpActCallOut INTEGER,
prtSpAlrRelayMode INTEGER,
prtSpStopBits INTEGER
}
prtSpCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg(1..255) being
accessed.
Idx of 255 relates to the TmpCnfg."
::= { prtSpCnfgEntry 1}
prtSpPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number of the SPor DP port.
For DXC, it is the port in the active DCL card:
- SP = 1
- NP ; DP = 2
For Kilomux, the port index is calculated as follows:
100*Slot+Ch.
For FCD, PRBi, the SP port index=1.
For Optimux-T3, the SP port index=71."
::= { prtSpCnfgEntry 2}
prtSpUsage OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
noUse (2),
nmsSlip (3),
nmsPpp (4),
muxSlip (5),
muxPpp (6),
terminal(7),
dialOut (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates what is the usage of the port."
::= { prtSpCnfgEntry 3}
prtSpRate OBJECT-TYPE
SYNTAX INTEGER
{
auto (1),
s300bps (2),
s1200bps (3),
s2400bps (4),
s4800bps (5),
s9600bps (6),
s19200bps (7),
s38400bps (8),
s57600bps (9),
s115200bps(10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the operation rate (speed) of the port.
auto - automatic rate selection, by the agent."
::= { prtSpCnfgEntry 4}
prtSpDataBits OBJECT-TYPE
SYNTAX INTEGER
{
dataBits7 (1),
dataBits8 (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the number of data bits in async
frame"
::= { prtSpCnfgEntry 5}
prtSpParity OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
odd (2),
even (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the parity mode in async frame"
::= { prtSpCnfgEntry 6}
prtSpCallOutMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
all (3),
major (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the call-out mode.
For DXC - this object is applicable only for the DP port (2)."
::= { prtSpCnfgEntry 7}
prtSpInterface OBJECT-TYPE
SYNTAX INTEGER
{
dce (1),
dte (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the supervisory port interface.
dce - the DACS appears as a DCE for the port.
dte - the DACS operates as a DTE, for connection via modem,
for the port."
::= { prtSpCnfgEntry 8}
prtSpCTS OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
on (2),
rts (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CTS line state. This object is applicable only for
port (1) = SP"
::= { prtSpCnfgEntry 9}
prtSpDcdDelay OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
d0 (2),
d10 (3),
d50 (4),
d100 (5),
d200 (6),
d300 (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DCD delay in msec.
d10 = delay of 10msec.
This object is applicable only for port (1) = SP"
::= { prtSpCnfgEntry 10}
prtSpDsr OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
on (2),
dtr (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DSR line state. This object is applicable only for
port (1) = SP"
::= { prtSpCnfgEntry 11}
prtSpNoOfRetries OBJECT-TYPE
SYNTAX Integer32 (0..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For DXC - this object is applicable only for port (2) = DP.
The number of dialing retries requested.
Default = 0"
::= { prtSpCnfgEntry 12}
prtSpWaitForConnect OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
t30sec (2),
t45sec (3),
t60sec (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For DXC - this object is applicable only for port (2) = DP.
Waiting time for connect, in seconds.
Default = 30 sec."
::= { prtSpCnfgEntry 13}
prtSpDialMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
tone (2),
pulse (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For DXC - this object is applicable only for port (2) = DP.
Dialing mode.
Default=tone"
::= { prtSpCnfgEntry 14}
prtSpAltNumMode OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For DXC - this object is applicable only for port (2) = DP.
It determines wether to use the alternate number or not.
Default = no."
::= { prtSpCnfgEntry 15}
prtSpPrimaryNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For DXC - this object is applicable only for port (2) = DP.
It is the Primary dialing number. "
::= { prtSpCnfgEntry 16}
prtSpAltNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For DXC - this object is applicable only for port (2) = DP.
It is the Alternate dialing number. This number
is applicable only if prtSpAltNumMode is 'yes'."
::= { prtSpCnfgEntry 17}
prtSpRoutProtocol OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
proprietary (3),
rip2 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the routing protocol of the port.
notApplicable - for DP."
::= { prtSpCnfgEntry 18}
prtSpCmd OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SP Command.
For LRS this parameter will be used for a Modem Command.
Upon NMS's Get operation for devices that this parameter
is notApplicable, agent will send NULL string."
::= { prtSpCnfgEntry 19}
prtSpActCallOut OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
always (2),
linkFail (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates when to Activate Call-Out.
It is used by FCD-T1/E1.
always - to activate call-out always.
linkFail - to activate call-out only when Link of Inband Management fails."
::= { prtSpCnfgEntry 20}
prtSpAlrRelayMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
normal (2),
invert (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Alarm Relay Mode.
notApplicable - for DP."
::= { prtSpCnfgEntry 21}
prtSpStopBits OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
stopBits1 (2),
stopBits1dot5 (3),
stopBits2 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates number of stop bits in an async frame."
::= { prtSpCnfgEntry 22}
--prt DIM (DXC Inverse Multiplexer) specific parameters
prtDimCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtDimCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= {prtDim 1}
prtDimCnfgEntry OBJECT-TYPE
SYNTAX PrtDimCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
for the TmpCnfg entry (prtDimCnfgIdx=255)."
INDEX {prtDimCnfgIdx, prtDimIdx }
::= { prtDimCnfgTable 1}
PrtDimCnfgEntry ::=
SEQUENCE {
prtDimCnfgIdx Integer32,
prtDimIdx Integer32,
prtDimTxMode INTEGER,
prtDimPolarity INTEGER,
prtDimClkMode INTEGER,
prtDimMaxDelay INTEGER,
prtDimMng INTEGER,
prtDimMngRoutProt INTEGER
}
prtDimCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg(1..255) being
accessed.
Idx of 255 relates to the TmpCnfg."
::= { prtDimCnfgEntry 1}
prtDimIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number of the
DIM card.
The convention used for DXC:
(IO slot number+10)*10 + 1
Example: port1 of IO slot 11 will be: 211 ."
::= { prtDimCnfgEntry 2}
prtDimTxMode OBJECT-TYPE
SYNTAX INTEGER
{
regularTx (2),
broadcast (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tx mode.
regularTx - the links are connected to a similar outfit on
the other side. In this mode, if a link fails,
the transmitted bandwidth is decreased
accordingly.
broadcast - the links are connected to MORE than one similar
outfit on the other side. In this mode, if a link
fails, the transmitted bandwidth is not affected "
::= { prtDimCnfgEntry 3}
prtDimPolarity OBJECT-TYPE
SYNTAX INTEGER
{
normalClk (2),
inverted (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Polarity."
::= { prtDimCnfgEntry 4}
prtDimClkMode OBJECT-TYPE
SYNTAX INTEGER
{
extDce (2),
dce (3),
smooth (4),
extSmooth(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock Mode.
smooth - a clock that is not 'pulsed'(has no 'gaps'). In this mode
the DXC does NOT receive back the clock signal.
extSmooth - same as 'smooth' but in this mode, the DXC receives back
the clock signal."
::= { prtDimCnfgEntry 5}
prtDimMaxDelay OBJECT-TYPE
SYNTAX INTEGER
{
t16msec (2),
t64msec (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Max Delay permitted between the links, in msec."
::= { prtDimCnfgEntry 6}
prtDimMng OBJECT-TYPE
SYNTAX INTEGER
{
disabled (2), --none
ts1 (3), --dedicated
dedicatedFr(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Use of DIM port for management.
disabled - no management on DIM
ts1 - 1 bit of TS1 is used for management."
::= { prtDimCnfgEntry 7}
prtDimMngRoutProt OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
proprietary (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mng Routing Protocol of the port.
none - when prtDimMng is 'disabled'."
::= { prtDimCnfgEntry 8}
prtDimDestTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtDimDestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= {prtDim 2}
prtDimDestEntry OBJECT-TYPE
SYNTAX PrtDimDestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation is valid only for the TmpCnfg entry
(prtDimDestCnfgIdx=255)."
INDEX {prtDestCnfgIdx, prtDestDimIdx, prtDestIdx }
::= { prtDimDestTable 1}
PrtDimDestEntry ::=
SEQUENCE {
prtDestCnfgIdx Integer32,
prtDestDimIdx Integer32,
prtDestIdx Integer32,
prtDest Integer32,
prtDestConnect INTEGER
}
prtDestCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg(1..255) being
accessed.
Idx of 255 relates to the TmpCnfg."
::= { prtDimDestEntry 1}
prtDestDimIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number of the
DIM card.
The convention used for DXC:
(IO slot number+10) & 1
Example: port1 of IO slot 11 will be: 211 ."
::= { prtDimDestEntry 2}
prtDestIdx OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a destination number of the
DIM card. "
::= { prtDimDestEntry 3}
prtDest OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination port,(of a T1/E1 port), that is connected to the
DIM card, for the specified Destination number.
0 = No destination port.
Else:
For external ports:
(IO Slot+10) & 1 for port 1
(IO Slot+10) & 3 for port 2
Example: port2 of IO slot 12 will be: 223 .
For internal ports :
(IO Slot+10) & 2 for port 1
(IO Slot+10) & 4 for port 2
(IO Slot+10) & 6 for port 3
(IO Slot+10) & 8 for port 4, etc..."
::= { prtDimDestEntry 4}
prtDestConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Connection Status of the specified destination number.
For a specified destination port, it depends both on the
status of the port and on the status of the far-end port.
Since this is a RO object, same value will be received for
all configurations."
::= { prtDimDestEntry 5}
--prtI - ISDN specific parameters table
prtICnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtICnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { prtI 1 }
prtICnfgEntry OBJECT-TYPE
SYNTAX PrtICnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtICnfgIdx, prtIIdx }
::= { prtICnfgTable 1}
PrtICnfgEntry ::=
SEQUENCE {
prtICnfgIdx Integer32,
prtIIdx Integer32,
prtIRate INTEGER,
prtIConnect INTEGER
}
prtICnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config. "
::= {prtICnfgEntry 1}
prtIIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify a port.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside,
SP.
* The ISDN B1, B2, D channels will be inside ports.
For port index, see product specification."
::= {prtICnfgEntry 2}
prtIRate OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
nc (2),
r2bit (3),
r4bit (4),
r8bit (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the port rate in bits.
Each TS contains 8 bits. Thus, 1 bit is equivalent to 8Kbps
rate."
::= {prtICnfgEntry 3}
prtIConnect OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"D channel connection.
no - disconnected
yes - connected. "
::= {prtICnfgEntry 4}
--prtHdsl - HDSL specific parameters table
prtHdslTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtHdslEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "HDSL port table."
::= { prtHdsl 1 }
prtHdslEntry OBJECT-TYPE
SYNTAX PrtHdslEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtHdslIdx }
::= { prtHdslTable 1}
PrtHdslEntry ::=
SEQUENCE {
prtHdslIdx Integer32,
prtHdslMode INTEGER,
prtHdslRptrType INTEGER,
prtHdslMaxRate INTEGER,
prtHdslLinkType INTEGER,
prtHdslCompSwVer DisplayString,
prtHdslCompHwVer DisplayString
}
prtHdslIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify a port.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside.
* The HDSL ports will be external.
For port index, see product specification."
::= {prtHdslEntry 1}
prtHdslMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
central (2),
remote (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the HDSL mode."
::= {prtHdslEntry 2}
prtHdslRptrType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
none (2),
hrpt (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Repeater between Near and Far modem.
none - no repeater exists between the modems
hrpt - HRPT repeater exists between the modems."
::= {prtHdslEntry 3}
prtHdslMaxRate OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
r192 (2),
r256 (3),
r320 (4),
r384 (5),
r448 (6),
r512 (7),
r576 (8),
r640 (9),
r768 (10),
r896 (11),
r1024 (12),
r1152 (13),
r1280 (14),
r1536 (15),
r1920 (16),
r2048 (17)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum Rate of the xDSL Line, in Kbps units.
This object can be Set only for a Central unit."
::= {prtHdslEntry 4}
prtHdslLinkType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
msdsl2w (2),
hdsl2w (3),
hdsl4w (4),
gDsl (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Link Type.
msdsl2w - MSDSL 2 Wire
hdsl2w - HDSL 2 Wire
hdsl4w - HDSL 4 Wire
gDsl - G.DSL "
::= {prtHdslEntry 5}
prtHdslCompSwVer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Software Version of the
component (Piggyback card) supporting this interface."
::= {prtHdslEntry 6}
prtHdslCompHwVer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Hardware Version of the
component (Piggyback card) supporting this interface."
::= {prtHdslEntry 7}
--DACS T3/E3 port configuration parameters. Applicable also for Optimux-T3 Links.
--
--These objects were entered in this private MIB, because they do not
--appear in RFC1407 (except prtT3E3LineLength which appears in meters) and in
--RFC-1407 MIB there is no reference to configuration number.
prtT3E3CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtT3E3CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"T3/E3 port configuration table."
::= { prtT3E3 1}
prtT3E3CnfgEntry OBJECT-TYPE
SYNTAX PrtT3E3CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry in the T3/E3 port configuration table."
INDEX { prtT3E3CnfgIdx, prtT3E3PrtIdx }
::= { prtT3E3CnfgTable 1}
PrtT3E3CnfgEntry ::=
SEQUENCE {
prtT3E3CnfgIdx
Integer32,
prtT3E3PrtIdx
Integer32,
prtT3E3Slt
INTEGER,
prtT3E3LineLength
INTEGER,
prtT3E3InbandMng
INTEGER,
prtT3E3AisFrame
INTEGER,
prtT3E3TxClockSource
INTEGER,
prtT3E3RoutProt
INTEGER,
prtT3E3AisTransmit
INTEGER
}
prtT3E3CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
For DXC, write operations can be performed only on the Temp Config.
For products that do not support configurations, always 1 will be used."
::= { prtT3E3CnfgEntry 1}
prtT3E3PrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
For DXC:
The same numbering as for prtGenPrtIdx.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside.
* The external ports convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
For Optimux-T3:
Link-A: 51
Link-B: 61 . "
::= { prtT3E3CnfgEntry 2}
prtT3E3Slt OBJECT-TYPE
SYNTAX INTEGER
{
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
standAlone (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify the slot where
the card is inserted in.
When the unit is stand-alone, this object is not applicable
and 255 will be used."
::= { prtT3E3CnfgEntry 3}
prtT3E3LineLength OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
len0p450ft (2),
len451p900ft (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the length of the ds3 line in feet.
It provides information for line build out circuitry if it exists
and can use this object to adjust the line build out.
len0p450ft = 0 - 450 feet
len451p900ft = 451 - 900 feet."
::= { prtT3E3CnfgEntry 4}
prtT3E3InbandMng OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
off (2),
cBit (3), --Cbit-Tx-Rx
cBitTxRxMng (4),
cBitTx (5),
cBitTxMng (6),
m13 (7),
cdpv (8),
nationalBit (9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique number to identify the Frame Type over the link.
For Optimux-T3: only values (4), (7) are supported."
::= {prtT3E3CnfgEntry 5}
prtT3E3AisFrame OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
unframed (2),
framed (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only for Optimux-T3.
It allows user to select whether the AIS sent will be framed or unframed."
::= { prtT3E3CnfgEntry 6}
prtT3E3TxClockSource OBJECT-TYPE
SYNTAX INTEGER
{
external(1), -- loopTiming
internal(2), -- localTiming
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tx Clock Source."
::= { prtT3E3CnfgEntry 7}
prtT3E3RoutProt OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
proprietary (3),
rip2 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Routing Protocol of the port.
This object is applicable only for T3 ports."
::= { prtT3E3CnfgEntry 8}
prtT3E3AisTransmit OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates if AIS signal will be transmitted over the tributary E3/DS3
upon failure."
::= { prtT3E3CnfgEntry 9}
--DACS General data, unrelated to a specific level or unit type
--Compressed data table - applicable for all the MIB leafs,
--Used only by NMS station
cmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF CmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { genDacsMux 1 }
cmprEntry OBJECT-TYPE
SYNTAX CmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {cmprTypeIdx, cmprCnfgIdx,cmprVersion,cmprSltIdx,cmprPrtIdx}
::= {cmprTable 1}
CmprEntry ::=
SEQUENCE {
cmprTypeIdx Integer32,
cmprCnfgIdx Integer32,
cmprVersion Integer32,
cmprSltIdx INTEGER,
cmprPrtIdx Integer32,
cmprObj OCTET STRING
}
cmprTypeIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Type of the Compressed
data referred (which table, which level, etc).
The type is a code according to a convention between
agent and NMS."
::= { cmprEntry 1}
cmprCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the configuration number the
Compressed information relates to."
::= { cmprEntry 2}
cmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the version of the internal format of
the Compressed data (the version of the convention used)."
::= { cmprEntry 3}
cmprSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number of the slot
position where the card is inserted.
When the unit is stand-alone or this object is not applicable,
255 will be used."
::= { cmprEntry 4}
cmprPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique identifier of the port,
the compressed information relates to.
For DXC - according to the order in the card of cmprSltIdx:
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card in odd or even numbers, as follows:
* For the outside/external ports, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
* The inside/internal ports, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 .
For FCD: see product's specification.
If the port number is irrelevant to this parameter (if it is
a system/card level alarm) the value will be 9999."
::= { cmprEntry 5}
cmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the compressed information itself,
according to a predefined format, both agent and NMS agreed
about."
::= { cmprEntry 6}
--mapLinkTable
mapLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF MapLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { genDacsMux 2}
mapLinkEntry OBJECT-TYPE
SYNTAX MapLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {mapLinkIdx}
::= {mapLinkTable 1}
MapLinkEntry ::=
SEQUENCE {
mapLinkIdx Integer32,
mapLinkSlotIdx INTEGER,
mapLinkPortIdx Integer32,
mapLinkState INTEGER
}
mapLinkIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the link"
::= {mapLinkEntry 1}
mapLinkSlotIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
standAlone (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted."
::= {mapLinkEntry 2}
mapLinkPortIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside,
SP.
In the DXC :
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card in odd or even numbers, as follows:
* For the outside/external ports, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
* The inside/internal ports, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 ."
::= {mapLinkEntry 3}
mapLinkState OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
down(2),
up(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of the link between
the two muxes"
::= {mapLinkEntry 4}
--Alarms List -
--
--
alrGenTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlrGenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { genDacsMux 3 }
alrGenEntry OBJECT-TYPE
SYNTAX AlrGenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { alrGenCode }
::= { alrGenTable 1}
AlrGenEntry ::=
SEQUENCE {
alrGenCode Integer32,
alrGenDescription DisplayString,
alrGenLevel INTEGER,
alrGenSlotType INTEGER,
alrGenSeverity INTEGER,
alrGenDebounce Integer32,
alrGenDefSeverity INTEGER
}
alrGenCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is a unique code number, identifying
a certain alarm."
::= { alrGenEntry 1}
alrGenDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry is a unique text description, of the alarm
corresponding to the specified code."
::= { alrGenEntry 2}
alrGenLevel OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
system (2),
card (3),
port (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm level."
::= {alrGenEntry 3}
alrGenSlotType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
ps (2),
cl (3),
io (4),
clAndIo (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot type that the alarm is relevant to.
clAndIo - an alarm that is relevant for both CL and IO slots."
::= {alrGenEntry 4}
alrGenSeverity OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables the user to select a severity for each alarm.
The severity is set per alarm code (same for all slots/ports
using this code)."
::= {alrGenEntry 5}
alrGenDebounce OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Debounce time for each alarm code, in seconds.
The meaning is, that an alarm will be 'declared' as ON (or OFF), only
after it was actually ON/OFF the Debouncing time selected by user.
0 = default debounce selection (each alarm has a default value).
250 = maximum value of seconds for debounce.
253 = mask = the alarm will Never be reported.
254 = default debounce selection (each alarm has a default value).
255 = not applicable "
::= {alrGenEntry 6}
alrGenDefSeverity OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reports the default severity of each alarm.
User can change the severity of the alarms defined by
this default via the alrGenSeverity object."
::= {alrGenEntry 7}
-- Traps
--NOTIFICATIONS
dacsMuxEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for DACS MUX."
::= { dacsMux 0 }
sanityCheckTrap NOTIFICATION-TYPE
OBJECTS { sysSSanityCheckStatus, sysDbaseDownloadCnfgIdxCmd }
STATUS current
DESCRIPTION
"This trap is sent after a data base download attempt.
It returns the sanity result status and the configuration
no.checked."
::= { dacsMuxEvents 1 }
dacsMuxAlarmsTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent when an alarm occurs."
::= { dacsMuxEvents 2 }
mdlConnectTrap NOTIFICATION-TYPE
OBJECTS {mdlSCardType, mdlSActivity}
STATUS current
DESCRIPTION
"This trap is sent when a card is removed."
::= { dacsMuxEvents 3 }
sysAlrStatusTrap NOTIFICATION-TYPE
OBJECTS { sysSAlrStatusAll, sysSAlrStatus }
STATUS current
DESCRIPTION
"This trap is sent upon any change in the value of any of
the variables."
::= { dacsMuxEvents 4 }
sysStatusChangedTrap NOTIFICATION-TYPE
OBJECTS {agnLed}
STATUS current
DESCRIPTION
"This trap is sent when Leds status is changed."
::= { dacsMuxEvents 5 }
cnfgUpdateTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent upon change of the active Configuration DB."
::= { dacsMuxEvents 6 }
sysRedundancyStatusTrap NOTIFICATION-TYPE
OBJECTS { sysDclRedundancyStatus }
STATUS current
DESCRIPTION
"The trap is sent upon change in Redundancy Status."
::= { dacsMuxEvents 7 }
sysRedundancyActiveCardTrap NOTIFICATION-TYPE
OBJECTS { sysDclOnline }
STATUS current
DESCRIPTION
"The trap is sent upon change of Active Main/CL Card."
::= { dacsMuxEvents 8 }
sysRedundancyActivePortTrap NOTIFICATION-TYPE
OBJECTS { sysCRdnOnline }
STATUS current
DESCRIPTION
"The trap is sent upon change of Active Port of Redundancy Group."
::= { dacsMuxEvents 9 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\modem.txt
--
-- MODMSYS MIB (MODEMS)
--Title: RAD's Modems MIB
--Version: 1.0
--Date: 24.12.95
--By: Yair Arian and Smadar Tauber
--File: modem.txt
--
--Last update: 15-May-2007 by Shay Harari
modmSys OBJECT IDENTIFIER ::= {radWan 4}
modmSystem OBJECT IDENTIFIER ::= {modmSys 1}
modmSa OBJECT IDENTIFIER ::= {modmSystem 1}
modmHub OBJECT IDENTIFIER ::= {modmSystem 2}
modmSaConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModmSaConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration parameters of the Central and Remote Modems.
The table will be RW for a Central agent and RO for a
Remote agent."
::= { modmSa 1 }
modmSaConfigEntry OBJECT-TYPE
SYNTAX ModmSaConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {modmSaConfigMode}
::= { modmSaConfigTable 1}
ModmSaConfigEntry ::=
SEQUENCE {
modmSaConfigMode INTEGER,
modmSaConfigLoopback INTEGER,
modmSaConfigAlrClearOnCmd INTEGER,
modmSaConfigAlrClearAllCmd INTEGER,
modmSaConfigTestClearCmd INTEGER,
modmSaConfigClkMaster INTEGER,
modmSaConfigResetStatistics INTEGER,
modmSaConfigActiveTs Integer32,
modmSaConfigReset INTEGER,
modmSaConfigRemote INTEGER,
modmSaConfigPsType INTEGER,
modmSaConfigWorkMode INTEGER
}
modmSaConfigMode OBJECT-TYPE
SYNTAX INTEGER {
central(1),
remote (2),
remote2(3),
remote3(4),
remote4(5),
remote5(6),
remote6(7),
remote7(8),
remote8(9),
remote9(10),
remote10(11)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mode indicates if the configuration parameters refer
the Central or the Remote Modem.
For AMC 102 the remote means regenerator.
There can be some regenerators connecting one by the other."
::= { modmSaConfigEntry 1}
modmSaConfigLoopback OBJECT-TYPE
SYNTAX INTEGER { noLoopback(1),
localPortLoop(2),
localLineLoop(3),
remPortLoop(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The possible loopbacks. It is not possible to have a
remPortLoop(4) in both, Central and Remote units
simultaneously."
::= { modmSaConfigEntry 2}
modmSaConfigAlrClearOnCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on, clears all the events,
both from the active alarms list and from the alarms buffer.
Upon completion, the value will automatically change to
off(2)."
::= { modmSaConfigEntry 3 }
modmSaConfigAlrClearAllCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on, clears all the alarms of the
alarm buffer and active alarms list. Upon completion, the
value will automatically change to off(2)."
::= { modmSaConfigEntry 4 }
modmSaConfigTestClearCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on, clears all the user-initiated
tests and loopbacks. The variable modmSaConfigLoopback should
automatically change to noLoopback. Upon completion, the
value will automatically change to off(2)."
::= { modmSaConfigEntry 5 }
modmSaConfigClkMaster OBJECT-TYPE
SYNTAX INTEGER
{
external(2),
internal(3),
station (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Modem configured as Central:
External - Locked to the clock signal provided by the user's
equipment by user's port.
Internal - Internal oscillator.
Station - Station clock (is relevant only for cards).
Modem configured as Remote:
External - Always locked to the recovered receive clock of
the HDSL line."
::= { modmSaConfigEntry 6 }
modmSaConfigResetStatistics OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In the on state all statistics counters (including E1
counters) are zeroed. Upon completion, the value will
automatically change to off(2).
Modems that do not support statistics - the value will
always be off (this object is not applicable for them).
notApplicable - for modems with no statistics support."
::= { modmSaConfigEntry 7 }
modmSaConfigActiveTs OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object will be RO for the Remote modem.
This is the number of active HDSL Time Slots, that
determines user's data rate.
Valid values: 1..maximum supported by the specific modem.
255 = notApplicable."
::= { modmSaConfigEntry 8 }
modmSaConfigReset OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
hw (3),
hwAndConfig (4),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset of modem.
hw - HW Reset. The configured values will not change.
hwAndConfig - HW Reset and initializing the default values.
notApplicable - for modems with no Reset support.
After 'hw' or 'hwAndConfig' is Set, agent will turn the
value to 'off'."
::= { modmSaConfigEntry 9 }
modmSaConfigRemote OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter enables or disables automatic configuration
of the remote moden in Proxy mode."
::= { modmSaConfigEntry 10 }
modmSaConfigPsType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
ac (2),
dc (3),
ac-dc (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of PS."
::= {modmSaConfigEntry 11}
modmSaConfigWorkMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
transparent (2),
termination(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The work mode indicates if devices work in transparent mode or termination mode."
::= { modmSaConfigEntry 12}
modmSaStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModmSaStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status of the Central and Remote Modems."
::= { modmSa 2 }
modmSaStatEntry OBJECT-TYPE
SYNTAX ModmSaStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {modmSaConfigMode}
::= { modmSaStatTable 1}
ModmSaStatEntry ::=
SEQUENCE {
modmSaStatHwTest Integer32,
modmSaStatAlarms OCTET STRING,
modmSaStatClkSrc INTEGER,
modmSaStatAlarmsMask OCTET STRING,
modmSaStatDeviceType INTEGER,
modmSaStatSwVersion DisplayString,
modmSaStatHwVersion DisplayString
}
modmSaStatHwTest OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The variable contains the results of the last hardware test.
It is a sum of 2**n where n is as follows:
0 - EPROM Failure (or Database chksum error)
1 - I/O Expander Error
2 - Counter Error
3 - HDSL Framer Failure
4 - Transceiver Failure
5 - NVRAM Failure (applicable only for HCD-E1>=r3)
6 - NSFIFO Failure (applicable for HCD-E1>=r3 and HCD-4)
7 - BERT Failure (applicable only for HCD-E1>=r3)
8 - E1 Framer Failure (applicable only for HCD-E1>=r3)
9 - XRT Failure (applicable only for HCD-E1>=r3)
10- HDSL Framer 1 Failure (applicable only for HCD-4)
11- HDSL Framer 2 Failure (applicable only for HCD-4)
12- DSP 1 Failure (applicable only for HCD-4)
13- DSP 2 Failure (applicable only for HCD-4)
14- XRT 1 Failure (applicable only for HCD-4)
15- XRT 2 Failure (applicable only for HCD-4)
if the variable is 0 then there are No Errors "
::= { modmSaStatEntry 1}
modmSaStatAlarms OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The variable contains the status of the Alarms in the alarm
buffer.
For bit location of each Alarm in the OctetString see Modem's
specification.
If the value is 0 then there are No 'On' Alarms in the alarm
buffer."
::= { modmSaStatEntry 2}
modmSaStatClkSrc OBJECT-TYPE
SYNTAX INTEGER
{
master (1),
fallback (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the source of the modem clock."
::= { modmSaStatEntry 3}
modmSaStatAlarmsMask OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(10))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable uses to mask alarms.
Location of each Alarm Mask in the OctetString,
is identical to the Alarm OctetString.
If the value is 0 then none of the alarms is masked."
::= { modmSaStatEntry 4}
modmSaStatDeviceType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
amc102SA (2),
amc102Card (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the device type (or utility)."
::= { modmSaStatEntry 5}
modmSaStatSwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display String of the modem SW version.
Format: W. X Y Z
0..9 0..99 A,B,E 0..99
(Z+P are optional.)
A=alpha, B=beta, E=end of development.
Examples: 2.23A8
3.4 "
::= {modmSaStatEntry 6}
modmSaStatHwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display String of the modem HW version."
::= {modmSaStatEntry 7}
modmSaAlarmBuffTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModmSaAlarmBuffEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The alarm buffer of the Central and Remote Modems."
::= { modmSa 3 }
modmSaAlarmBuffEntry OBJECT-TYPE
SYNTAX ModmSaAlarmBuffEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {modmSaConfigMode,modmSaAlarmBuffIndex}
::= { modmSaAlarmBuffTable 1}
ModmSaAlarmBuffEntry ::=
SEQUENCE {
modmSaAlarmBuffIndex Integer32,
modmSaAlarmBuffCode Integer32,
modmSaAlarmBuffTime DisplayString,
modmSaAlarmBuffState INTEGER
}
modmSaAlarmBuffIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the alarm buffer Table."
::= { modmSaAlarmBuffEntry 1}
modmSaAlarmBuffCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The code of the alarm. For text description of each Alarm
code see Modem's specification."
::= { modmSaAlarmBuffEntry 2}
modmSaAlarmBuffTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp at which the alarm has occurred. The format
is hh:mm:ss "
::= { modmSaAlarmBuffEntry 3}
modmSaAlarmBuffState OBJECT-TYPE
SYNTAX INTEGER { off(2),
on(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The new status of the alarm."
::= { modmSaAlarmBuffEntry 4}
-- Modem parameters - all parameters refer the Agent itself only
modmSaParam OBJECT IDENTIFIER ::= {modmSa 4}
modmSaMode OBJECT-TYPE
SYNTAX INTEGER
{
central (1),
remote (2),
remote2 (3),
remote3 (4),
remote4 (5),
remote5 (6),
remote6 (7),
remote7 (8),
remote8 (9),
remote9 (10),
remote10 (11)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The agent's current mode.
For AMC 102 remote means regenerator.
There can be some regenerators connecting one by the other."
::= {modmSaParam 1}
modmSaFarEndIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the agent on the far end. If the Remote
modem is NOT an agent, the variable will be 0.0.0.0.
Set - will be enabled only to a Central modem that works as
Proxy."
::= {modmSaParam 2}
modmSaFarEndType OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
sa (2), --same product as near-end
card (3), --same product as near-end
saLowCost (4), --same product as near-end
hcdSa (5),
hcdSaL (6),
hcdCard (7),
htu2Sa (8),
htu2Card (9),
htuE1Sa (10),
htuE1SaL (11),
htuE1Card(12),
hcd4Sa (13),
hcdPF (14),
unmanaged(100) --MP/DXC card
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the Far-End modem."
::= {modmSaParam 3}
modmSaRptrType OBJECT-TYPE
SYNTAX INTEGER
{
none (2),
hrpt (3),
flexDsl (4),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Repeater between the Near and Far modem.
none - no repeater exists between the modems.
notApplicable - for modems that do not support this feature."
::= {modmSaParam 4}
modmSaLearnLineMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
manually (2),
automatic (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is for the central unit only.
Indicates if learn the regenerator order and number every time there
is a fail in line or manually by user."
::= {modmSaParam 5}
modmSaNumOfUnits OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object will hold the number of regenerators in the line."
::= {modmSaParam 6}
-- Repeater Table
modmSaRptrTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModmSaRptrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Repeaters parameters known to the central modem."
::= { modmSa 5 }
modmSaRptrEntry OBJECT-TYPE
SYNTAX ModmSaRptrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {modmSaIndex, modmSaRptrIndex}
::= { modmSaRptrTable 1}
ModmSaRptrEntry ::=
SEQUENCE {
modmSaIndex Integer32,
modmSaRptrIndex Integer32,
modmSaRptrTest INTEGER,
modmSaRptrActiveAlarms OCTET STRING,
modmSaRptrAlrClear INTEGER,
modmSaRptrVersion DisplayString
}
modmSaIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify the modem that reports about the repeater."
::= {modmSaRptrEntry 1}
modmSaRptrIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the Repeater."
::= { modmSaRptrEntry 2 }
modmSaRptrTest OBJECT-TYPE
SYNTAX INTEGER {
none (1),
loopLHrpt (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The possible loopbacks."
::= { modmSaRptrEntry 3 }
modmSaRptrActiveAlarms OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the Alarms. Each bit represents a specific
alarm .
For bit location of each alarm in the
Octet String see modem's specification.
If the value is 0 then there are No Alarms."
::= { modmSaRptrEntry 4 }
modmSaRptrAlrClear OBJECT-TYPE
SYNTAX INTEGER {
off (1),
on (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on, clears all the active (On)
alarms of the repeater. Upon completion, the value will
automatically change to off(2).."
::= { modmSaRptrEntry 5 }
modmSaRptrVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SW/HW version of the repeater"
::= { modmSaRptrEntry 6 }
--modmHub OBJECT IDENTIFIER ::= {modmSystem 2}
--Modem - Hub Parameters
modmHubParam OBJECT IDENTIFIER ::= {modmHub 1}
modmHubTermConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status: is the Terminal connected or not."
::= {modmHubParam 1}
modmHubController OBJECT-TYPE
SYNTAX INTEGER
{
nms (1),
terminal (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selection of Hub controller during normal operation. If
'terminal' is selected, NMS can still return control to
itself by setting this object to 'nms'. While terminal is
the controller, NMS can perform Get operations and Set trap
masks."
::= {modmHubParam 2}
modmHubId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"4 Hex characters, identifying the Hub. The last two
characters (least significant) will be displayed on the
Hub's CL card by a 7 segment display."
::= {modmHubParam 3}
modmHubT1E1 OBJECT-TYPE
SYNTAX INTEGER
{
other (1),
t1 (2),
e1 (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The T1/E1 value determines the Hub's clock rate."
::= {modmHubParam 4}
modmHubClockSource OBJECT-TYPE
SYNTAX INTEGER
{
other (1),
external (2),
internal (3),
g703Section10 (4),
receive (5),
station (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock source."
::= {modmHubParam 5}
modmHubClockRate OBJECT-TYPE
SYNTAX INTEGER
{
e1r2048000 (1),
e1r1024000 (2),
e1r512000 (3),
e1r256000 (4),
e1r128000 (5),
e1r64000 (6),
e1r32000 (7),
e1r16000 (8),
e1r8000 (9),
t1r1544000 (31),
t1r772000 (32),
t1r386000 (33),
t1r193000 (34),
t1r96500 (35),
t1r48250 (36),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock Rate in bps. The rates are the original T1/E1 rates
or the rates divided by 2n.
For modmHubT1E1=e1, instances (1)-(9) are applicable.
For modmHubT1E1=t1, instances (31)-(36) are applicable.
For modmHubT1E1=other, instance (255) is applicable."
::= {modmHubParam 6}
modmHubIpMode OBJECT-TYPE
SYNTAX INTEGER
{
single (1),
multi (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"single - Upon BootP request from S-MOD, CM-2 will
assign a 'private IP' (CM-2 IP + slot number of S-MOD),
which will be applicable only between the S-MOD and CM-2.
multi - CM-2 assigns up to 12/24 consequent IP addresses.
One for each S-MOD according to the slot number."
::= {modmHubParam 7}
modmHubInstallation OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The string will be a multiple set of 16 bit corresponds
to its card position, and each set corresponds to a modem,
where set #1 is the first modem on each card, and set n is
the n-st modem in each card.
1........10.....16|1........10.....16|
modem 1 | modem 2 |
MSB LSB
Bits 1-3 and 16 will be ignored.
For LRS-52 detailed bit assignment see product's spec."
::= {modmHubParam 8}
--Modem - Hub Alarms
modmHubAlarms OBJECT IDENTIFIER ::= {modmHub 2}
modmHubActiveAlarms OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the Alarms for each Slot. Each bit represents a
Slot of the Hub. For bit location of each Alarm in the
Octet String see Hub's specification.
A bit is '1' (On) if at least one 'On' alarm exists for this
Slot.
If the value is 0 then there are No 'On' Alarms in any Slot.
For LRS52 - read 'modem' instead of the word 'slot'"
::= {modmHubAlarms 1}
modmHubAlrClear OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on, clears all the active (On)
alarms of the Hub. Upon completion, the value will
automatically change to off(2)."
::= {modmHubAlarms 2}
modmHubMaskAlarms OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mask of Alarms per Slot. Each bit represents a
Slot of the Hub. For bit location of each Slot in the
Octet String see Hub's specification (same as
modmHubActiveAlarms).
When a bit is '1' (On) it is masked ; all alarms of this Slot
should not be sent and Alarm LED should not be lit. This
mask overrides the mask on the specific alarms of each Slot
or modem.
If the value is 0 then all alarms should be sent.
For LRS52 - read 'modem' instead of the word 'slot'."
::= {modmHubAlarms 3}
modmMdl OBJECT IDENTIFIER ::= {modmSys 2}
modmMdlParam OBJECT IDENTIFIER ::= {modmMdl 1}
mdlParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Parameters table of cards in the Hub."
::= { modmMdlParam 1 }
mdlParamEntry OBJECT-TYPE
SYNTAX MdlParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mdlSIdx }
::= { mdlParamTable 1}
MdlParamEntry ::=
SEQUENCE {
mdlSIdx INTEGER,
mdlSNoOfModems Integer32,
mdlCardType INTEGER,
mdlSPanelType INTEGER,
mdlSLed OCTET STRING,
mdlSActiveAlarms OCTET STRING,
mdlAlrClear INTEGER,
mdlSConfigMismatch INTEGER,
mdlConfigSource INTEGER,
mdlConfigGround INTEGER,
mdlCapabilities OCTET STRING,
mdlClockSource INTEGER
}
mdlSIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
cl (3),
io1 (4),
io2 (5),
io3 (6),
io4 (7),
io5 (8),
io6 (9),
io7 (10),
io8 (11),
io9 (12),
io10 (13),
io11 (14),
io12 (15)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify a slot position in the modems
Hub."
::= { mdlParamEntry 1}
mdlSNoOfModems OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of modems on this card.
255 = notApplicable. "
::= { mdlParamEntry 2 }
mdlCardType OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
empty (2),
ps48V (3),
ps110V (4),
ps230V (5),
cm2 (6),
smod (7),
asmi24 (8),
asmi31 (9),
asmi32 (10),
asmi50 (11),
mtmi20 (12),
fomi40 (13),
fomiE1T1 (14),
asm40cd (15),
asmi50cd (16),
fomi40cd (17),
fomiE1T1cd (18),
ps110V-24 (19),
ps230V-24 (20),
ps48V-24 (21),
asmi31cq (22),
asmi51cq (23),
asmi51cd (24),
asmi52cd (25),
asmi52cq (26),
asmi52cd4W (27), -- ASMi52CD with 4 wire
asmi52cqEth (28),
asmi52cd4wNew (29), -- ASMi52CD New with 4 wire
asmi52cd4wNewEth(30),
--SMODs
fomiE3 (51),
fomiT3 (52),
optimux4E1 (53),
optimux4T1 (54),
amc102 (55),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Card's type."
::= { mdlParamEntry 3 }
mdlSPanelType OBJECT-TYPE
SYNTAX INTEGER
{
empty (1),
f2 (2), --rj45AndDb25
f3 (3), --rj45AndG703
f5 (5), --2*rj45And2*26HD
f6 (6), --rj45+2BNCAnd2*26HD
f7 (7), --asmi32
f9 (9), --rj45AndV35
f10 (10), --rj45AndRj45
f11 (11), --rj45And2rj45
f12 (12), --rj45AndX21
f13 (13), --2*rj45And2*rj45
f14 (14), --2*4381And2*rj45
f18 (15), --scsi68And4*rj11
f19 (16), --scsi68And4*TB
f22 (17), --iripRj45
f20 (18), --4TB2And4RJ45 for CQ
f21 (19), --4TB2AndDB25 for CQ
f23 (20), --2RJ45And2IP for CD
-- (see cont. later)
-- Panels with an Optical connector
fO1 (21), --stAndDb25
fO2 (22), --stAndV35
fO3 (23), --stAndDb15
fO4 (24), --stAndG703
fO5 (25), --scAndDb25
fO6 (26), --scAndV35
fO7 (27), --scAndDb15
fO8 (28), --scAndG703
fO9 (29), --stAndEthernet
fO10 (30), --scAndEthernet
fO11 (31), --2*st/fcAnd2*SCSI
fO12 (32), --2*st/fcAnd2*rj45
fO13 (33), --2*scAnd2*SCSI
fO14 (34), --2*scAndr2*j45
fO15 (35), --(2*st/fcAnd2*4381)eth
fO16 (36), --(2*scAnd2*4381)eth
fO17 (37), --(2*st/fcAndBNC)e3/t3
fO18 (38), --(2*scAndBNC)e3/t3
fO19 (39), --(2*st/fcAnd2*bnc)wdm
fO20 (40), --(2*scAnd2*scsi)wdm
fO21 (41), --(4*MBNC And 2*st/fc)e1/t1
fO22 (42), --(4*MBNC And 2*sc)e1/t1
--Power Supply panels
ps230And115 (81), --PS 230V, 115V without phantom
psp230And115 (82), --PS 230V, 115V with phantom
ps48 (83), --PS 48V without phantom
psp48 (84), --PS 48V with phantom
--Panels of CM2 card (CL)
f1Cm2 (91), --CM2 UTP
f2Cm2 (92), --CM2 BNC
f3Cm2 (93), --CM2 V35
f4Cm2 (94), --CM2 RS-530
f5Cm2 (95), --CM2 X21
f1Cm2New (96), --CM2 UTP with embedded LEDs
--Regular panels (cont.)
f24 (121), --2RJ45And2RJ11 for CD
f25 (122), --2RJ45AndDB25 for CD
f27 (123), --4RJ45And4TB for CQ (Line connectors first)
f28 (124), --2RJ45And4RJ11 balance for CQ (Line connectors first)
f29 (125), --2RJ45AndDB25 unbalance for CQ (Line connectors first)
f30 (126), --2RJ45And4TB for CD 4W New
f31 (127), --SCSI68And4RJ11 for CD 4W New
f32 (128), --SCSI68And4TB2 for CD 4W New
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LRS-12 Card connectors' panel type.
fx - IMOD panels
psxxx - PS panels
fxCm2 - CM-2 panels."
::= { mdlParamEntry 4 }
mdlSLed OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LEDs status on the card . Each led will be represented by 4
bits where the first 2 bits (left) will specify the Status :
(00=NA, 01=OFF, 10=ON, 11=BLINK),
and the next two bits (right) will specify the Color :
(00=GREEN, 01=RED, 10=YELLOW, 11=ORANGE).
This object is not applicable for the 'smod', 'empty' and
'unknown' card types. For them 0 will be sent. "
::= { mdlParamEntry 5}
mdlSActiveAlarms OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is applicable only for PS and CL cards.
It gives the status of the Alarms for each Slot. Each bit
represents an alarm in the slot. For bit location of each
Alarm in the Octet String see Hub's specification.
A bit is '1' if the alarm is On.
If the value is 0 then there are No 'On' Alarms in the Slot."
::= {mdlParamEntry 6}
mdlAlrClear OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on, clears all the active (On)
alarms of the Slot. Upon completion, the value will
automatically change to off(2)."
::= {mdlParamEntry 7}
mdlSConfigMismatch OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3),
line1 (4),
line2 (5),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is applicable only for slots containing
IMOD cards.
ON - when CM-2 realizes that the configuration of the
Near-End modem1 is different from that of its Far-End
modem.
In this case it expects user to decide which of the
modems' configuration is the correct one (by
'mdlConfigSource'), or change the incorrect modem
configuration.
When one of these conditions is fulfilled, the value
will automatically turn to OFF. Applicable for a single
modem.
Line1 - The same as for ON but for modem-1 line. Applicable
for a double modem.
Line2 - The same as for ON but for modem-2 line. Applicable
for a double modem.
OFF - Near-End and Far-End modems have the same
configuration (OK). "
::= {mdlParamEntry 8}
mdlConfigSource OBJECT-TYPE
SYNTAX INTEGER
{
nearEnd (1),
farEnd (2),
nearEnd2 (3),
farEnd2 (4),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only for slots containing
IMOD cards, when mdlSConfigMismatch=on/on1/on2.
nearEnd - Near End - 1 modem has the correct configuration
farEnd - Far End - 1 has the correct configuration
nearEnd - Near End - 2 has the correct configuration
farEnd - Far End - 2 has the correct configuration."
::= {mdlParamEntry 9}
mdlConfigGround OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disconnect (2),
connect (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables to connect or disconnect an IMOD card to the
ground.
disconnect - not connected to ground.
connect - connected to ground.
notApplicable - for other cards."
::= {mdlParamEntry 10}
mdlCapabilities OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the optional capabilities that are implemented by this module
and are manageable through this MIB.
For each capability 1 BIT is allocated in each Octet starting from the LSB.
If the value of the BIT = 1, the capability is Enabled.
If the value of the BIT = 0, the capability is Disabled.
For bit assignment, refer to device specification.
Capabilities example:
Low Speed Operation - BIT 0
CPE Operation - BIT 1"
::= { mdlParamEntry 11}
mdlClockSource OBJECT-TYPE
SYNTAX INTEGER
{
-- (1)-(8) are reserved for values similar to modmPrtLineClkSrc
internal (9),
external (10),
system (11),
receive (12),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Clock Source of the Card.
Applicable for ASMi-52 modems only.
internal - means that the card uses its own Internal Clock
external - means that the card uses the Clock received from an
External DTE port of a modem. The modem used has to be
specified in a separate MIB object (modmPrtLineClkSrcPort
of the 1st modem in the card).
system - means that the card uses the Clock of the CM2 card of LRS-24.
receive - means that every modem of the card will use the Clock
received from its own Line."
::= { mdlParamEntry 12}
--Modem data - the modem can either belong to the Hub or
-- be a Far-End modem connected to a modem of
-- the Hub. The data applies mainly for IMOD cards.
-- This table is used also by DXC and MP, for data about
-- far unit of each external port of D8SL/MSL card.
-- For DXC and MP, modemIdx=ifIndex of External port of D8SL/MSL card.
modem OBJECT IDENTIFIER ::= {modmSys 3}
modemParam OBJECT IDENTIFIER ::= {modem 1}
modemParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModemParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This parameters table is applicable mainly for modems that are
not agents."
::= { modemParam 1 }
modemParamEntry OBJECT-TYPE
SYNTAX ModemParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { modemIdx }
::= { modemParamTable 1}
ModemParamEntry ::=
SEQUENCE {
modemIdx Integer32,
modemType INTEGER,
modemConfigMode INTEGER,
modemModeTemporary INTEGER,
modemNoOfDte Integer32,
modemWire INTEGER,
modemMngLink INTEGER,
modemReset INTEGER,
modemSlot INTEGER,
modemHubId OCTET STRING,
modemIpAddress IpAddress,
modemPsType INTEGER,
modemMaskTraps Integer32,
modemActiveAlarms OCTET STRING,
modemAlrClear INTEGER,
modemAlrBufClear INTEGER,
modemMaskSignaling OCTET STRING,
modemPanelType INTEGER,
modemIType INTEGER,
modemRcvPower Integer32,
modemSwVersion Integer32,
modemLed OCTET STRING,
modemRemoteType INTEGER,
modemConfigPhantom INTEGER,
modemRemoteTestEnable INTEGER,
modemSwVerString DisplayString,
modemRemoteIdx Integer32,
modemHwVerString DisplayString,
modemResetStatistics INTEGER,
modemMaxRate INTEGER,
modemBoxMaterial INTEGER,
modemLowSpeed INTEGER,
modemDevicePorts Integer32,
modemUserName DisplayString,
modemRowValidity INTEGER,
modemTftpCmd INTEGER
}
modemIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For LRS:
A unique number to identify a modem in the Hub or its
far-end modem.
For DXC:
This will be the ifIndex of the External Port of D8SL card,
that works with this modem/product.
For MP:
This will be the ifIndex of the External Port of MSL card,
that works with this modem/product."
::= {modemParamEntry 1}
modemType OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
asmi24c (2),
asmi31c (3),
asmi32c (4),
asmi50c (5),
mtmi20c (6),
fomi40c (7),
fomiE1T1c (8),
asm40cd (9),
asmi31cq (10),
asmi51cq (11),
asmi51cd (12),
asmi52cq (13),
asmi52cd (14),
asmi52cd4W (15),
asmi52cqEth(16),
asmi52cd4wNew (17),
asmi52cd4wNewEth(18),
asmi24r (22),
asmi31r (23),
asmi32r (24),
asmi50r (25),
mtmi20r (26),
asmi24 (42),
asmi31 (43),
asmi32 (44),
asmi50 (45),
mtmi20 (46),
fomi40 (47),
fomiE1T1 (48),
asmi51 (49),
asmi52S (50), --Slave
asmi52M (51), --Master
asmi52L (52), --SA Low Cost
asmi54 (53), --SA
lrs52 (71)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modem type.
xxxxxx - Stand-Alone modem.
xxxxxxc - Modem on a Card within a Hub having an Agent.
xxxxxxr - Modem on a Card within a Hub having no Agent.
xxxxxxcd - Modem on a Double-Modem Card within a Hub
having an Agent. Each modem has it's own CPU.
xxxxxxcq - Modem on a Quad-Modem Card within a Hub
having an Agent. One CPU for all modems.
lrs52 - Modem within the LRS-52 device."
::= {modemParamEntry 2}
modemConfigMode OBJECT-TYPE
SYNTAX INTEGER {
master (1),
slave (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The mode identifies if the Modem operates as the Master
unit or as the Slave unit.
For modems having a jumper for this function, this object
will be RO.
This object can be Set only to the Master unit when
modemModeTemporary=no (the Far-End unit will receive its
new mode from the Central unit, via management link
between the modems).
Regarding other objects (except modemModeTemporary):
If Modem is Master, it can perform RW operations for
both Master and Slave modem.
If Modem is Slave, it can perform RO operations for
both Master and Slave modem."
::= {modemParamEntry 3}
modemModeTemporary OBJECT-TYPE
SYNTAX INTEGER {
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies if the Modem operates as
modemConfigMode value (Master/Slave) temporarily or
permanently.
This object can be Set only when:
- modemConfigMode=master AND modemModeTemporary=no
- modemConfigMode=slave AND modemModeTemporary=yes
this is an exception to the fact that all other objects
in this case are RO.
The other unit will receive its value for this object
from the Set unit, via management link between the modems."
::= {modemParamEntry 4}
modemNoOfDte OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of DTE ports in the modem."
::= {modemParamEntry 5}
modemWire OBJECT-TYPE
SYNTAX INTEGER
{
w2wire (1),
w4wire (2),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Modem wiring."
::= {modemParamEntry 6}
modemMngLink OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Communication status between the pair of modems."
::= {modemParamEntry 7}
modemReset OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
hwReset (3),
configReset(4),
factoryReset (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is set to the value of hwReset(3),
the module performs HW Reset.
When this object is set to the value of configReset(4),
the modem performs Configuration Reset, which will set
the modem to the last parameters it was configured.
For LRS 24, this value used for Resetting Modem Line.
When this object is set to the value of factoryReset (5),
the modem performs factory Reset, which will set
the modem to the factory configuration"
::= {modemParamEntry 8}
modemSlot OBJECT-TYPE
SYNTAX INTEGER
{
io1 (4),
io2 (5),
io3 (6),
io4 (7),
io5 (8),
io6 (9),
io7 (10),
io8 (11),
io9 (12),
io10 (13),
io11 (14),
io12 (15),
io13 (16),
io14 (17),
io15 (18),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify the slot position of the
modem (card)in its Hub.
notApplicable - for a stand-alone modem or Rack 214
card.
io13..io15 - are for DXC use in case of a Far-Unit that is D8SL card."
::= {modemParamEntry 9}
modemHubId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(2))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"4 Hex characters, identifying the Hub. The last two
characters (least significant) will be displayed on the
Hub's CL card by a 7 segment display.
This object is applicable only for LRS-12 modems."
::= {modemParamEntry 10}
modemIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write -- originally read-only
STATUS current
DESCRIPTION
"For LRS:
The IP address of the LRS-12 agent . If the modem is NOT
an LRS-12 card, the variable will be 0.0.0.0.
For DXC and MP: the IP Address of the Far-End unit."
::= {modemParamEntry 11}
modemPsType OBJECT-TYPE
SYNTAX INTEGER
{
ac (1),
dc (2),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of PS, for a stand-alone modem.
notApplicable - for LRS-12 or Rack 214 card."
::= {modemParamEntry 12}
modemMaskTraps OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value determines the modem traps the agent should mask
and not send to the management console.
The value is a sum of 2**n, where n is a bit assigned to a
certain trap. For bit assignment see modem's specification.
Value of '0', means that no trap should be masked."
::= {modemParamEntry 13}
modemActiveAlarms OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the Alarms for each modem. Each bit represents an
alarm. For bit location of each Alarm in the Octet String
see modem's specification.
A bit is '1' if the alarm is On.
If the value is 0 then there are no 'On' alarms on this
modem."
::= {modemParamEntry 14}
modemAlrClear OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on, clears all the active (On)
alarms of the modem. Upon completion, the value will
automatically change to off(2)."
::= {modemParamEntry 15}
modemAlrBufClear OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on, clears all the alarms in the
buffer alarm of the modem. Upon completion, the value will
automatically change to off(2)."
::= {modemParamEntry 16}
modemMaskSignaling OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mask of Signals per modem. When a signal is masked,
the agent will not send the modemSignalingChange TRAP, upon
change of this signal's value and it will not enter
the History Log.
Each bit represents a signal of the modem.
For bit location of each signal in the Octet String see
modem's specification.
When a bit is '1' (On) it is masked ."
::= {modemParamEntry 17}
modemPanelType OBJECT-TYPE
SYNTAX INTEGER
{
f2 (2), --rj45AndDb25
f3 (3), --rj45AndG703
f7 (7), --asmi32
f9 (9), --rj45AndV35
f10 (10), --rj45AndRj45
f11 (11), --rj45And2rj45
f12 (12), --rj45AndX21
f13 (13), --2*rj45And2*rj45
f14 (14), --2*4381And2*rj45
f18 (15), --scsi68And4*rj11
f19 (16), --scsi68And4*TB
f22 (17), --iripRj45
f20 (18), --4TB2And4RJ45 for CQ
f21 (19), --4TB2AndDB25 for CQ
f23 (20), --2RJ45And2IP for CD
-- (see cont. later)
-- Panels with an Optical connector
fO1 (21), --stAndDb25
fO2 (22), --stAndV35
fO3 (23), --stAndDb15
fO4 (24), --stAndG703
fO5 (25), --scAndDb25
fO6 (26), --scAndV35
fO7 (27), --scAndDb15
fO8 (28), --scAndG703
fO9 (29), --stAndEthernet
fO10 (30), --scAndEthernet
fO11 (31), --2*st/fcAnd2*SCSI
fO12 (32), --2*st/fcAnd2*rj45
fO13 (33), --2*scAnd2*SCSI
fO14 (34), --2*scAndr2*j45
fO15 (35), --(2*st/fcAnd2*4381)eth
fO16 (36), --(2*scAnd2*4381)eth
fO17 (37), --(2*st/fcAndBNC)e3/t3
fO18 (38), --(2*scAndBNC)e3/t3
fO19 (39), --(2*st/fcAnd2*bnc)wdm
fO20 (40), --(2*scAnd2*scsi)wdm
fO21 (41), --(4*MBNC And 2*st/fc)e1/t1
fO22 (42), --(4*MBNC And 2*sc)e1/t1
pcu (101),
lcd (102),
--Regular panels (cont.)
f24 (121), --2RJ45And2RJ11 for CD
f25 (122), --2RJ45AndDB25 for CD
f27 (123), --4RJ45And4TB for CQ (Line connectors first)
f28 (124), --2RJ45And4RJ11 balance for CQ (Line connectors first)
f29 (125), --2RJ45AndDB25 unbalance for CQ (Line connectors first)
f30 (126), --2RJ45And4TB for CD 4W New
f31 (127), --SCSI68And4RJ11 for CD 4W New
f32 (128), --SCSI68And4TB2 for CD 4W New
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The panel type of the modem.
This parameter is applicable only for Far-End modems that
are stand-alone or cards of another LRS-12. It enables
displaying the correct panel of the modem.
- Stand-alone : applicable only for ASMi-24 and ASMi-50
modems.
pcu - with connector for Portable Control Unit
lcd - LCD display and buttons.
- LRS-12 card : fx is the connectors panel of the modem. "
::= {modemParamEntry 18}
modemIType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Is the modem Intelligent (ASMi-xx) ; or not - (ASM-xx).
This object is used only for the Far-End modem (with the
relevant modemIdx).
notApplicable - for ASMi-32, ASMi-50
no - modem is NOT I-Type so it doesn't have a management
link to its pair-modem.
yes - modem is I-Type so it has a management link to its
pair-modem."
::= {modemParamEntry 19}
modemRcvPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Rx Level of the modem, in dBm.
Valid values: -99 .. 0.
255=not applicable. "
::= {modemParamEntry 20}
modemSwVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SW version of the modem, multiplied by 100.
Example: 115 means SW ver: 1.15
0 = notApplicable. "
::= {modemParamEntry 21}
modemLed OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LEDs status on the card . Each led will be represented by 4
bits where the first 2 bits (left) will specify the Status :
(00=NA, 01=OFF, 10=ON, 11=BLINK),
and the next two bits (right) will specify the Color :
(00=GREEN, 01=RED, 10=YELLOW, 11=ORANGE).
This object is applicable for modems located on a card that contains
more than one modem. When not applicable 0 will be sent. "
::= { modemParamEntry 22}
modemRemoteType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
unknown (2),
sa (3),
single (4),
double (5),
rack (6),
quad (7),
saSlave (8),
fcdIp (9),
dxcCard4p (10), --DXC 4 links
dxcCard8p (11), --DXC 8 links
lrs52 (12),
double4W (13), -- double with 4 wire.
asmi52A (14), -- SA
fcdIpM (15),
mpShdslCard (16),
sa4W (17), -- SA with 4 wire.
asmi52L (18), -- SA Low Cost
quadEth (19),
double4wNew (20),
double4wNewEth (21)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remote modem card type. Not applicable to near - end modems.
For LRS-52, sa(3)=saMaster."
::= {modemParamEntry 23}
modemConfigPhantom OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off (2),
on (3),
notValid (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables to supply electric power to remote devices (SA modem,
repeaters), through the current module.
off - remote devices will not get PS through the current modem.
on - remote devices will get PS through the current modem.
notApplicable - for a modem without a phantom unit.
notValid - In case the unit exists but is not functioning."
::= {modemParamEntry 24}
modemRemoteTestEnable OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter identifies if the remote Modem allowed to operates
tests.
For Near-End modems this parameter will be ON."
::= {modemParamEntry 25}
modemSwVerString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display String of the modem SW version.
Format: X. Y Z P
0..9 0..99 A,B,E 0..99
(Z+P are optional.)
A=alpha, B=beta, E=end of development.
Examples: 2.23A8
3.4 "
::= {modemParamEntry 26}
modemRemoteIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"0 = notApplicable.
For LRS:
The Remote modem index.
Applicable only for modemRemoteType=double(5) or quad(7).
For DXC, LRS-52 and MP:
- if Remote unit is an LRS Quad card: remote modem index (1..4)
- if Remote unit is a DXC D8SL card: external port index (1..8).
- if Remote unit is an LRS-52 modem: 1..24.
- if Remote unit is a MP MSL card: external port index (1..4 or 1..8)."
::= {modemParamEntry 27}
modemHwVerString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display String of the modem HW version."
::= {modemParamEntry 28}
modemResetStatistics OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In the on state all statistics counters (including E1
counters) are zeroed. Upon completion, the value will
automatically change to off(2).
notApplicable - for modems with no statistics support."
::= {modemParamEntry 29}
modemMaxRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
r2Mbps (2),
r4Mbps (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum rate supported by the modem "
::= {modemParamEntry 30}
modemBoxMaterial OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
plastic (2),
metal (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shape (picture) of modem box is related to box material.
Applicable for ASMi52 SA "
::= {modemParamEntry 31}
modemLowSpeed OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter enables working at low rates,
when working with a serial interface (V.35,X.21) modem
opposite to a E1/T1 interface modem."
::= {modemParamEntry 32}
modemDevicePorts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value indicates the existence of optional ports (which are not Line or DTE).
The value is a sum of 2**n, where n is a bit assigned to a
certain port. For bit assignment see modem's specification.
For ASMi-52 SA, the bit assigned for Alarm Relay port is 0,
therefore Agent will return '1' if this optional port exists.
Value of '0', means that no such optional port exists."
::= {modemParamEntry 33}
modemUserName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the user to configure a name
for the selected modem."
::= {modemParamEntry 34}
modemRowValidity OBJECT-TYPE
SYNTAX INTEGER
{
invalid (1),
valid (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether this row is valid or not.
It is an optional parameter."
::= {modemParamEntry 35}
modemTftpCmd OBJECT-TYPE
SYNTAX INTEGER
{
noOp (1),
swdl (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines the TFTP Command.
After performing the command, the Agent will automatically set
this variable to noOp(1)."
::= {modemParamEntry 36}
modemAlrBuffer OBJECT IDENTIFIER ::= {modem 2}
modemAlrBufTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModemAlrBufEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This parameters table is applicable only for modems that are
not agents."
::= { modemAlrBuffer 1 }
modemAlrBufEntry OBJECT-TYPE
SYNTAX ModemAlrBufEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { modemIdx, modemAlrBufIdx }
::= { modemAlrBufTable 1}
ModemAlrBufEntry ::=
SEQUENCE {
modemAlrBufIdx Integer32,
modemAlrBufCode Integer32,
modemAlrBufState INTEGER,
modemAlrBufDate DisplayString,
modemAlrBufTime DisplayString,
modemAlrBufSysUpTime TimeTicks
}
modemAlrBufIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Running index of the alarm buffer table."
::= {modemAlrBufEntry 1}
modemAlrBufCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The code of the alarm. For text description of each Alarm
code see Modem's specification."
::= {modemAlrBufEntry 2}
modemAlrBufState OBJECT-TYPE
SYNTAX INTEGER { off(2),
on(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The new status of the alarm."
::= {modemAlrBufEntry 3}
modemAlrBufDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Date at which the alarm has occurred. The format
is according to the entered systemDate format."
::= {modemAlrBufEntry 4}
modemAlrBufTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp at which the alarm has occurred. The format
is hh:mm:ss "
::= {modemAlrBufEntry 5}
modemAlrBufSysUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time the alarm has occurred.
This object is applicable only for products that cannot support
calendar date (modemAlrBufDate) and time (modemAlrBufTime)
When not applicable, this object contains a zero value"
::= {modemAlrBufEntry 6}
modemStatistics OBJECT IDENTIFIER ::= {modem 3}
modemGeneralTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModemGeneralEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The IMOD General data Table. The data is specific to each
modem."
::= { modemStatistics 1 }
modemGeneralEntry OBJECT-TYPE
SYNTAX ModemGeneralEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the modemGeneralTable. This entry is per modem.
Each modem has a specific index, which identifies it."
INDEX {modemIdx}
::= { modemGeneralTable 1}
ModemGeneralEntry ::=
SEQUENCE {
modemCurrentElapsedTime Integer32,
modemValidIntervals Integer32
}
modemCurrentElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since the beginning
of the current error-measurement period."
::= {modemGeneralEntry 1}
modemValidIntervals OBJECT-TYPE
SYNTAX Integer32 (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of previous intervals for which data was
collected.
The value will be 96 unless the interface was brought on-line
within the last 24 hours, in which case the value will be the
number of complete 15 minute intervals since the interface
has been online."
::= {modemGeneralEntry 2}
modemIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModemIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The IMOD Interval Table. The data is specific to each
modem."
::= { modemStatistics 2 }
modemIntervalEntry OBJECT-TYPE
SYNTAX ModemIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the modemIntervalTable. This entry is per modem
and per interval selected."
INDEX {modemIdx, modemIntervalNumber}
::= { modemIntervalTable 1}
ModemIntervalEntry ::=
SEQUENCE {
modemIntervalNumber Integer32,
modemSyncLoss Integer32,
modemLineQuality INTEGER,
modemLineUtility Integer32,
modemRTS Integer32,
modemCD Integer32,
modemBertResult DisplayString,
modemBpvError OCTET STRING,
modemFoError OCTET STRING
}
modemIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number between 1 and 96, where 1 is the most recently
completed 15 minute interval and 96 is the least recently
completed 15 minutes interval (assuming that all 96
intervals are valid). Maximum valid number is
modemValidIntervals."
::= {modemIntervalEntry 1}
modemSyncLoss OBJECT-TYPE
SYNTAX Integer32 (0..101)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percent of interval, SyncLoss signal is ON.
101 = notApplicable/unknown. "
::= {modemIntervalEntry 2}
modemLineQuality OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
bad (2),
mid (3),
good (4),
unknown (5),
syncLoss(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Quality of Line for the selected modem, in the selected valid
interval."
::= {modemIntervalEntry 3}
modemLineUtility OBJECT-TYPE
SYNTAX Integer32 (0..101)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percent of interval, Line is utilized.
101 = notApplicable/unknown. "
::= {modemIntervalEntry 4}
modemRTS OBJECT-TYPE
SYNTAX Integer32 (0..101)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percent of interval, RTS signal is ON.
101 = notApplicable/unknown. "
::= {modemIntervalEntry 5}
modemCD OBJECT-TYPE
SYNTAX Integer32 (0..101)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percent of interval, CD signal is ON.
101 = notApplicable/unknown. "
::= {modemIntervalEntry 6}
modemBertResult OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Result of BERT for the selected modem, in the selected
valid interval."
::= {modemIntervalEntry 7}
modemBpvError OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..1))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"BPV Error.
The Octet will be built as follows:
MSB 7 6 5 4 3 2 1 0 LSB
|__| |______________|
y=0..3 x=0..63
BPV Error = x * (10**y)
An Agent that does not support this object will send Size=0."
::= {modemIntervalEntry 8}
modemFoError OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..1))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"FO Error.
The Octet will be built as follows:
MSB 7 6 5 4 3 2 1 0 LSB
|__| |______________|
y=0..3 x=0..63
FO Error = x * (10**y)
An Agent that does not support this object will send Size=0."
::= {modemIntervalEntry 9}
modmPrt OBJECT IDENTIFIER ::= {modmSys 4}
-- Supervisory Port (SP)
modmSpPort OBJECT IDENTIFIER ::= {modmPrt 1}
modmPrtSpTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModmPrtSpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration parameters of the Local or Remote Modem
Supervisory Ports. The port will be identified by its
specific ifIndex value."
::= { modmSpPort 1 }
modmPrtSpEntry OBJECT-TYPE
SYNTAX ModmPrtSpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {ifIndex}
::= { modmPrtSpTable 1}
ModmPrtSpEntry ::=
SEQUENCE {
modmPrtSpUsage INTEGER,
modmPrtSpRate INTEGER,
modmPrtSpDataBits INTEGER,
modmPrtSpParity INTEGER,
modmPrtSpInterface INTEGER,
modmPrtSpCTS INTEGER,
modmPrtSpDcdDelay INTEGER,
modmPrtSpDsr INTEGER
}
modmPrtSpUsage OBJECT-TYPE
SYNTAX INTEGER
{
nmsSlip (2),
terminal (3),
agentSlip (4),
nmsPpp (5),
agentPpp (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates what is the usage of the port."
::= { modmPrtSpEntry 1}
modmPrtSpRate OBJECT-TYPE
SYNTAX INTEGER
{
auto (1),
s300bps (2),
s1200bps (3),
s2400bps (4),
s4800bps (5),
s9600bps (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the operation rate (speed) of the
port.
auto - automatic rate selection, by the agent."
::= {modmPrtSpEntry 2}
modmPrtSpDataBits OBJECT-TYPE
SYNTAX INTEGER
{
dataBits7 (1),
dataBits8 (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the number of data bits in the
word format."
::= {modmPrtSpEntry 3}
modmPrtSpParity OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
odd (2),
even (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the parity mode in async frame"
::= { modmPrtSpEntry 4}
modmPrtSpInterface OBJECT-TYPE
SYNTAX INTEGER
{
dce (1),
dte (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the supervisory port interface.
dce - the modem appears as a DCE for the SP port.
dte - the modem operates as a DTE, for connection via modem,
for the SP port."
::= { modmPrtSpEntry 5}
modmPrtSpCTS OBJECT-TYPE
SYNTAX INTEGER
{
on (2),
rts (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CTS line state. "
::= {modmPrtSpEntry 6}
modmPrtSpDcdDelay OBJECT-TYPE
SYNTAX INTEGER
{
d0 (2),
d10 (3),
d50 (4),
d100 (5),
d200 (6),
d300 (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DCD delay in msec.
d10 = delay of 10msec."
::= { modmPrtSpEntry 7}
modmPrtSpDsr OBJECT-TYPE
SYNTAX INTEGER
{
on (2),
dtr (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DSR line state."
::= {modmPrtSpEntry 8}
-- Ds1 Port (T1/E1)
modmDs1Port OBJECT IDENTIFIER ::= {modmPrt 2}
modmPrtDs1Table OBJECT-TYPE
SYNTAX SEQUENCE OF ModmPrtDs1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Statistics parameters of the Local and Remote modem Ds1 ports.
The port will be identified by its specific ifIndex value."
::= { modmDs1Port 1 }
modmPrtDs1Entry OBJECT-TYPE
SYNTAX ModmPrtDs1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {ifIndex}
::= { modmPrtDs1Table 1}
ModmPrtDs1Entry ::=
SEQUENCE {
modmPrtDs1HdslPriorityBumping OCTET STRING,
modmPrtDs1Sync INTEGER,
modmPrtDs1BpvLastMin Gauge32,
modmPrtDs1BpvMax Gauge32,
modmPrtDs1LineLength INTEGER,
modmPrtDs1CRCAvgError Gauge32,
modmPrtDs1DtsToRemote INTEGER
}
modmPrtDs1HdslPriorityBumping OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"The 4 bytes represent the 32 time slots of the E1 frame.
Each bit can be set to one, making the corresponding time
slot a HIGH priority. Bits 16 and 32 cannot be modified by the
user. The maximum number of HIGH priority time slots is 16.
The default value is LOW, i.e., 0. This variable is RO in the
Remote unit."
-- DEFVAL { 0 }
::= { modmPrtDs1Entry 1 }
modmPrtDs1Sync OBJECT-TYPE
SYNTAX INTEGER { itu(2),
fast(3),
s62411(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The standard used for the time required for the E1 port to return
to normal operation after local loss of synchronization. Default:
itu(2)."
-- DEFVAL { 2 }
::= { modmPrtDs1Entry 2 }
modmPrtDs1BpvLastMin OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is applicable only for an E1 active port.
It provides the number of BPV (BiPolar Violation) events
detected during the last minute."
::= { modmPrtDs1Entry 3 }
modmPrtDs1BpvMax OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is applicable only for an E1 active port.
It provides the maximal number of BPV (BiPolar Violation)
events (per minute), detected during the worst minute."
::= { modmPrtDs1Entry 4 }
modmPrtDs1LineLength OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
len0p133ft (2),
len134p266ft (3),
len267p399ft (4),
len400p533ft (5),
len534p655ft (6),
fcc68 (7),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the line length mask parameter used only
for T1/DSU interfaces.
len400p533ft=length range: 400ft to 533ft
'fcc68' - provides compliance with the FCC 68.308 Option A
output pulse mask. "
::= { modmPrtDs1Entry 5 }
modmPrtDs1CRCAvgError OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counts the average number of CRC error events per second.
The average is updated every second"
::= { modmPrtDs1Entry 6 }
modmPrtDs1DtsToRemote OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether DTS (Dedicated TS)
is transmitted to remote unit."
::= { modmPrtDs1Entry 7 }
modmHdslPort OBJECT IDENTIFIER ::= {modmPrt 3}
modmPrtHdslCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModmPrtHdslCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The HDSL Current Table. The data collected is for the current
15-minute interval."
::= { modmHdslPort 1 }
modmPrtHdslCurrentEntry OBJECT-TYPE
SYNTAX ModmPrtHdslCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the HDSL Current Table. This entry is per HDSL
interface (LOOP1 or LOOP2). Each modem (Central/Remote) has
a specific ifIndex value for the port, which identifies it.
For FDSL it is used for any xDSL interface."
INDEX {ifIndex}
::= { modmPrtHdslCurrentTable 1}
ModmPrtHdslCurrentEntry ::=
SEQUENCE {
modmPrtHdslCurrentElapsedTime Integer32,
modmPrtHdslCurrentESs Gauge32,
modmPrtHdslCurrentSESs Gauge32,
modmPrtHdslCurrentBBEs Gauge32,
modmPrtHdslCurrentUASs Gauge32,
modmPrtHdslCurrentNoiseMargin Integer32,
modmPrtHdslCurrentAttenuation Integer32
}
modmPrtHdslCurrentElapsedTime OBJECT-TYPE
SYNTAX Integer32 (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since the beginning
of the current error-measurement period."
::= { modmPrtHdslCurrentEntry 1 }
modmPrtHdslCurrentESs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Errored Seconds encountered by an HDSL
interface in the current 15 minute interval. An Errored
Second is any second containing one or more Errored Blocks
or an occurrence of an SDP."
::= { modmPrtHdslCurrentEntry 2 }
modmPrtHdslCurrentSESs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Severely Errored Seconds encountered by an HDSL
interface in the current 15 minute interval. An SES is any
second containing more than 30% Errored Blocks (50 blocks) or
one or more SDPs."
::= { modmPrtHdslCurrentEntry 3 }
modmPrtHdslCurrentBBEs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Background Block Errors encountered by an HDSL
interface in the current 15 minute interval. A BBE is an
errored block not occurring as part of an SES."
::= { modmPrtHdslCurrentEntry 4 }
modmPrtHdslCurrentUASs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Unavailable Seconds encountered by an HDSL
interface in the current 15 minute interval. A UAS is any
second in which a failed signal state exists. A failure state
is declared when 10 consecutive SESs occur, and is cleared
after 10 consecutive seconds free of an SES."
::= { modmPrtHdslCurrentEntry 5 }
modmPrtHdslCurrentNoiseMargin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current noise margin in DB.
This object is not an accumulative one, therefore
it's value will appear only in this table."
::= { modmPrtHdslCurrentEntry 6 }
modmPrtHdslCurrentAttenuation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current attenuation in DB.
This object is not an accumulative one, therefore
it's value will appear only in this table."
::= { modmPrtHdslCurrentEntry 7 }
modmPrtHdslIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModmPrtHdslIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The HDSL Interval Table. The data collected is for the last 96
completed 15-minute intervals."
::= { modmHdslPort 2 }
modmPrtHdslIntervalEntry OBJECT-TYPE
SYNTAX ModmPrtHdslIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the HDSL Interval Table. This entry is per an HDSL
interface (LOOP1 or LOOP2) and per 15 minute interval. The
port and unit (Central/Remote) is identified by its specific
ifIndex value.
For FDSL it is used for any xDSL interface."
INDEX {ifIndex, modmPrtHdslIntervalNumber}
::= { modmPrtHdslIntervalTable 1}
ModmPrtHdslIntervalEntry ::=
SEQUENCE {
modmPrtHdslIntervalNumber Integer32,
modmPrtHdslIntervalESs Gauge32,
modmPrtHdslIntervalSESs Gauge32,
modmPrtHdslIntervalBBEs Gauge32,
modmPrtHdslIntervalUASs Gauge32,
modmPrtHdslIntervalESR Integer32,
modmPrtHdslIntervalSESR Integer32,
modmPrtHdslIntervalBBER Integer32,
modmPrtHdslIntervalValidData TruthValue
}
modmPrtHdslIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number between 1 and 96, where 1 is the most recently completed
15 minute interval and 96 is the least recently completed 15 minutes
interval (assuming that all 96 intervals are valid)."
::= { modmPrtHdslIntervalEntry 1 }
modmPrtHdslIntervalESs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Errored Seconds encountered by an HDSL interface in
one of the previous 96, individual 15 minute, intervals."
::= { modmPrtHdslIntervalEntry 2 }
modmPrtHdslIntervalSESs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Severely Errored Seconds encountered by an HDSL interface in
one of the previous 96, individual 15 minute, intervals."
::= { modmPrtHdslIntervalEntry 3 }
modmPrtHdslIntervalBBEs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Background Block Errors encountered by an HDSL interface in
one of the previous 96, individual 15 minute, intervals."
::= { modmPrtHdslIntervalEntry 4 }
modmPrtHdslIntervalUASs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Unavailable Seconds encountered by an HDSL interface in
one of the previous 96, individual 15 minute, intervals."
::= { modmPrtHdslIntervalEntry 5 }
modmPrtHdslIntervalESR OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ratio of ESs to 900 seconds, encountered by an HDSL interface in
one of the previous 96, individual 15 minute, intervals."
::= { modmPrtHdslIntervalEntry 6 }
modmPrtHdslIntervalSESR OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ratio of SESs to 900 seconds, encountered by an HDSL interface in
one of the previous 96, individual 15 minute, intervals."
::= { modmPrtHdslIntervalEntry 7 }
modmPrtHdslIntervalBBER OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ratio of BBEs to 900 seconds, encountered by an HDSL interface in
one of the previous 96, individual 15 minute, intervals."
::= { modmPrtHdslIntervalEntry 8 }
modmPrtHdslIntervalValidData OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates if the data for this interval is valid."
::= { modmPrtHdslIntervalEntry 9 }
modmPrtHdslTotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModmPrtHdslTotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The HDSL Total Table. The data collected is the cumulative
sum of the various statistics for the 24 hour period
preceding the current interval."
::= { modmHdslPort 3 }
modmPrtHdslTotalEntry OBJECT-TYPE
SYNTAX ModmPrtHdslTotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the HDSL Total Table. This entry is per an HDSL
interface (LOOP1 or LOOP2). The port and unit (Central/Remote)
is identified by its specific ifIndex value.
For FDSL it is used for any xDSL interface."
INDEX {ifIndex}
::= { modmPrtHdslTotalTable 1}
ModmPrtHdslTotalEntry ::=
SEQUENCE {
modmPrtHdslTotalValidIntervals Integer32,
modmPrtHdslTotalESs Gauge32,
modmPrtHdslTotalSESs Gauge32,
modmPrtHdslTotalBBEs Gauge32,
modmPrtHdslTotalUASs Gauge32
}
modmPrtHdslTotalValidIntervals OBJECT-TYPE
SYNTAX Integer32 (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of previous intervals for which valid data was
collected.
The value will be 96 unless the interface was brought on-line
within the last 24 hours, in which case the value will be the
number of complete 15 minute intervals since the interface
has been online."
::= { modmPrtHdslTotalEntry 1 }
modmPrtHdslTotalESs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Errored Seconds encountered by an HDSL
interface in the previous 24 hour interval."
::= { modmPrtHdslTotalEntry 2 }
modmPrtHdslTotalSESs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Severely Errored Seconds encountered by an HDSL
interface in the previous 24 hour interval."
::= { modmPrtHdslTotalEntry 3 }
modmPrtHdslTotalBBEs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Background Block Errors encountered by an HDSL
interface in the previous 24 hour interval."
::= { modmPrtHdslTotalEntry 4 }
modmPrtHdslTotalUASs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Unavailable Seconds encountered by an HDSL
interface in the previous 24 hour interval."
::= { modmPrtHdslTotalEntry 5 }
modmPrtHdslTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModmPrtHdslEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The HDSL Table."
::= { modmHdslPort 4 }
modmPrtHdslEntry OBJECT-TYPE
SYNTAX ModmPrtHdslEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the HDSL Table. The port and unit (Central/Remote)
is identified by its specific modmPrtHdslIndex value."
INDEX {modmPrtHdslIndex}
::= { modmPrtHdslTable 1}
ModmPrtHdslEntry ::=
SEQUENCE {
modmPrtHdslIndex Integer32,
modmPrtHdslDedicatedTs Integer32,
modmPrtHdslPriorityBumping OCTET STRING,
modmPrtHdslMngProtocol INTEGER,
modmPrtHdslRoutProtocol INTEGER,
modmPrtHdslInbandMngRate INTEGER,
modmPrtHdslPriorityBumpingEnable INTEGER,
modmPrtHdslPriorityBumpingTimeout Integer32
}
modmPrtHdslIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The HDSL port index. In some cases it can equal ifIndex."
::= { modmPrtHdslEntry 1}
modmPrtHdslDedicatedTs OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The HDSL Current Dedicated TS.
Valid values: 0..31.
255 = None (no dedicated TS)."
::= { modmPrtHdslEntry 2 }
modmPrtHdslPriorityBumping OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The 4 bytes represent time slots 0..31 of the E1 frame.
Each bit can be set to '1', making the corresponding time slot a HIGH priority.
Bit 0 is always HIGH (cannot be modified by the user).
The maximum number of HIGH priority time slots is: 16 for E1 ; 13 for T1
(including TS0).
The default value is LOW, i.e., 0."
-- DEFVAL { 0 }
::= { modmPrtHdslEntry 3 }
modmPrtHdslMngProtocol OBJECT-TYPE
SYNTAX INTEGER {
off (2),
dedicatedTs (4),
dedicatedPpp(5),
dedicatedFr (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique number to identify an Inband management over the
link."
::= { modmPrtHdslEntry 4 }
modmPrtHdslRoutProtocol OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
proprietary (3),
rip2 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Inband Mng Routing Protocol of the port.
When modmPrtHdslMngProtocol is 'dedicatedPpp'-'proprietary' and
'rip2' are applicable.
For other values - only 'proprietary' is applicable."
::= {modmPrtHdslEntry 5}
modmPrtHdslInbandMngRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
r4k (2),
r8k (3),
r12k (4),
r16k (5),
r32k (6),
r64k (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique number to identify the rate of the Inband management.
It is applicable only when modmPrtHdslDedicatedTs <> (255 Or 0)."
::= {modmPrtHdslEntry 6}
modmPrtHdslPriorityBumpingEnable OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Priority Bumping Mode.
It is relevant only for 4W interfaces."
::= { modmPrtHdslEntry 7}
modmPrtHdslPriorityBumpingTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Priority Bumping Timeout in minutes.
It is relevant only for 4W interfaces (2 lines of 2W each).
Upon failure of one of the 2W lines,
Timeout is the time period that the agent should wait
until moving the traffic to the working 2W line."
::= { modmPrtHdslEntry 8 }
-- DTE (User) Port
modmDtePort OBJECT IDENTIFIER ::= {modmPrt 4}
modmPrtDteTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModmPrtDteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration parameters of the Master and Slave Modem DTE
Ports. The port and unit (Master/Slave) is identified by
its specific modmPrtDteIndex value."
::= { modmDtePort 1 }
modmPrtDteEntry OBJECT-TYPE
SYNTAX ModmPrtDteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {modmPrtDteIndex}
::= { modmPrtDteTable 1}
ModmPrtDteEntry ::=
SEQUENCE {
modmPrtDteIndex Integer32,
modmPrtDteProtocol INTEGER,
modmPrtDteDataBits INTEGER,
modmPrtDteStopBits INTEGER,
modmPrtDteRate INTEGER,
modmPrtDteCtsDelay INTEGER,
modmPrtDteParity INTEGER,
modmPrtDteIfType INTEGER,
modmPrtDteRlbEnable INTEGER,
modmPrtDteAlbEnable INTEGER,
modmPrtDteRtsDcdEnable INTEGER,
modmPrtDteDsrDtrEnable INTEGER,
modmPrtDteSignaling OCTET STRING,
modmPrtDteLoops INTEGER,
modmPrtDteTests Integer32,
modmPrtDteClearAllTests INTEGER,
modmPrtDteBertResult DisplayString,
modmPrtDteErrCorrect INTEGER,
modmPrtDteV54DigitalTest INTEGER,
modmPrtDteV54DigitalTestStatus INTEGER,
modmPrtDteTestTimeOut Integer32,
modmPrtDteAlarmForwarding INTEGER
}
modmPrtDteIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DTE port index."
::= { modmPrtDteEntry 1}
modmPrtDteProtocol OBJECT-TYPE
SYNTAX INTEGER {
sync (2),
async (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DTE port Protocol."
::= { modmPrtDteEntry 2}
modmPrtDteDataBits OBJECT-TYPE
SYNTAX INTEGER {
dataBits6 (1),
dataBits7 (2),
dataBits8 (3),
dataBits9 (4),
dataBits10 (5),
dataBits11 (6),
dataBits5 (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DTE number of data bits."
::= { modmPrtDteEntry 3}
modmPrtDteStopBits OBJECT-TYPE
SYNTAX INTEGER {
stopBits1Bit (1),
stopBits1dot5Bits (2),
stopBits2Bits (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DTE minimum number of stop bits in the tx async frame."
::= { modmPrtDteEntry 4}
modmPrtDteRate OBJECT-TYPE
SYNTAX INTEGER {
r300bps (1),
r600bps (2),
r1200bps (3),
r2400bps (4),
r4800bps (5),
r9600bps (6),
r14400bps (7),
r16000bps (8),
r19200bps (9),
r28800bps (10),
r32000bps (11),
r38400bps (12),
r48000bps (13),
r56000bps (14),
r57600bps (15),
r64000bps (16),
r72000bps (17),
r96000bps (18),
r112000bps (19),
r115200bps (20),
r128Kbps (21),
r144Kbps (22),
r192Kbps (23),
r256Kbps (24),
r320Kbps (25),
r384Kbps (26),
r448Kbps (27),
r512Kbps (28),
r576Kbps (29),
r640Kbps (30),
r704Kbps (31),
r768Kbps (32),
r1024Kbps (33),
r1536Kbps (34),
r1544Kbps (35),
r2048Kbps (36),
e1 (37),
t1 (38),
r896Kbps (39),
r960Kbps (40),
r1152Kbps (41),
r1920Kbps (42),
r34Mbps (43), -- e3
r45Mbps (44), -- t3
r1088Kbps (45),
r1216Kbps (46),
r1344Kbps (47),
r1408Kbps (48),
r1472Kbps (49),
r1600Kbps (50),
r1664Kbps (51),
r1728Kbps (52),
r1792Kbps (53),
r1856Kbps (54),
r1984Kbps (55),
r1280Kbps (56),
r2304Kbps (57),
r832Kbps (58),
r2176Kbps (59),
r2432Kbps (60),
r2560Kbps (61),
r2688Kbps (62),
r2816Kbps (63),
r2944Kbps (64),
r3072Kbps (65),
r3200Kbps (66),
r3328Kbps (67),
r3456Kbps (68),
r3584Kbps (69),
r3712Kbps (70),
r3840Kbps (71),
r3968Kbps (72),
r4096Kbps (73),
r2112Kbps (74),
r2240Kbps (75),
r4224Kbps (76),
r4352Kbps (77),
r4480Kbps (78),
r4608Kbps (79),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DTE port rate."
::= { modmPrtDteEntry 5}
modmPrtDteCtsDelay OBJECT-TYPE
SYNTAX INTEGER
{
d0 (1),
d1 (2),
d7 (3),
d8 (4),
d10 (5),
d70 (6),
disabled (7),
enabled (8),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CTS/RTS delay, in msec.
dxx = xx msec.
notApplicable - for ASMi-31, ASMi-32."
::= { modmPrtDteEntry 6}
modmPrtDteParity OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
odd (2),
even (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the parity mode in async frame."
::= { modmPrtDteEntry 7}
modmPrtDteIfType OBJECT-TYPE
SYNTAX INTEGER
{
v24 (1),
rs530 (2),
x21 (3),
g703 (4), --E1
v36 (5),
v35 (6),
g703r64k (7),
hdb3 (8),
ethernet (9), --UTP
g703T1 (10),
ethBNC (11),
noIR (15),
ipUtp (16),
ethQ (17),
rs530WA (18),
v35WA (19),
g704E1 (20),
ethQN (21),
g704T1 (22),
ethQV (23),
other (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface type of the DTE port."
::= { modmPrtDteEntry 8}
modmPrtDteRlbEnable OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable Remote Loop-Back on this modem, externally
initiated."
::= {modmPrtDteEntry 9}
modmPrtDteAlbEnable OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable Analog Loop-Back on this modem, externally
initiated."
::= {modmPrtDteEntry 10}
modmPrtDteRtsDcdEnable OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable RTS-DCD."
::= {modmPrtDteEntry 11}
modmPrtDteDsrDtrEnable OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable DSR-DTR."
::= {modmPrtDteEntry 12}
modmPrtDteSignaling OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Each bit represents a specific signal state.
1 - means : signal is ON , Enabled, Yes (exists)
0 - means : signal is OFF, Disabled, No .
For detailed bit assignment see product's spec."
::= {modmPrtDteEntry 13}
modmPrtDteLoops OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
ana (2),
rem (3),
anaAndBert (4),
remAndBert (5),
bert (6),
twoBerts (7),
digital (8),
dual (9),
clb (10),
clbAndBert (11),
dteLLB (12),
lineRLB (13)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Loops that can be run on the DTE port.
none - no loop (stop running loop)
ana - Local Analog Line loop
rem - Remote Analog Line loop
anaAndBert - ana & BERT together
remAndBert - rem & BERT together
bert - BERT test
twoBerts - 2 BERT test
digital - A remote loop on the local modem.
dual - Remote loop and ana loop.
clb - Local loop on the DTE connection. Must
be set together with modmPrtDteTestTimeOut parameter.
Applicable to asmi51/CQ/CD.
clbAndBert - CLB & BERT together.
Applicable to asmi51/CQ/CD.
dteLLB - DTE LLB (Local Loopback on DTE Digital Interface)
lineRLB - Line RLB (Remote Loopback on Line Analog Interface)."
::= {modmPrtDteEntry 14}
modmPrtDteTests OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is a mask which indicates
- for Get: which tests are running on the DTE port.
- for Set: tests the user wishes to start or stop.
Each test has its specific bit.
- '1' means the test runs (Set: should run).
- '0' means the test does not run (Set: should stop):
TEST BIT
----------- ---
LEDs 0
e.g : If the return value is 1 the LEDs test is running."
::= {modmPrtDteEntry 15}
modmPrtDteClearAllTests OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on, clears all the running loops
and tests of the DTE port. Upon completion, the value will
automatically change to off(2)."
::= {modmPrtDteEntry 16}
modmPrtDteBertResult OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Result of BERT for the selected DTE port.
Applicable only if BERT is running on the DTE port."
::= {modmPrtDteEntry 17}
modmPrtDteErrCorrect OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off (2),
on (3),
onBurst (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"notApplicable - for modems that do not support this object
on - will start a random error correction process.
onBurst - will start a burst error correction process.
Setting this object to 'off', will stop any kind of error correction process."
::= {modmPrtDteEntry 18}
modmPrtDteV54DigitalTest OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable(2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables to start a remote digital loopback upon recognition of a special pattern.
disable - will not start a digital loopback when a special pattern is
recognized.
enable - will start a loopback upon recognition of a special pattern."
::= {modmPrtDteEntry 19}
modmPrtDteV54DigitalTestStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off (2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether a remote digital test was triggered by a pattern
by the remote modem or not.
no - the digital test wasn't triggered by a pattern by the remote modem.
yes - the digital test was triggered by a pattern by the remote modem."
::= {modmPrtDteEntry 20}
modmPrtDteTestTimeOut OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the timeout for LLB test.
0=Forever "
::= {modmPrtDteEntry 21}
modmPrtDteAlarmForwarding OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB object defines whether to enable or disable Alarm Forwarding for this port.
It means whether this port will be affected by the failure of its respective Line port."
::= {modmPrtDteEntry 22}
-- Line port
modmLinePort OBJECT IDENTIFIER ::= {modmPrt 5}
modmPrtLineTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModmPrtLineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration parameters of the Master and Slave Modem Line
Ports. The port and unit (Master/Slave) is identified by
its specific modmPrtLineIndex value."
::= { modmLinePort 1 }
modmPrtLineEntry OBJECT-TYPE
SYNTAX ModmPrtLineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {modmPrtLineIndex}
::= { modmPrtLineTable 1}
ModmPrtLineEntry ::=
SEQUENCE {
modmPrtLineIndex Integer32,
modmPrtLineClkSrc INTEGER,
modmPrtLineTxLevel INTEGER,
modmPrtLineRxLevel INTEGER,
modmPrtLineOutImp INTEGER,
modmPrtLineInImp INTEGER,
modmPrtLineCarrCntrl INTEGER,
modmPrtLineRAP INTEGER,
modmPrtLineWaveLength INTEGER,
modmPrtLineCdSense INTEGER,
modmPrtLineAIS INTEGER,
modmPrtLineCoding INTEGER,
modmPrtLineLength INTEGER,
modmPrtLineClkSrcPort INTEGER,
modmPrtLineDteClkConfig INTEGER,
modmPrtLineMaskAlr INTEGER
}
modmPrtLineIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Line port index."
::= {modmPrtLineEntry 1}
modmPrtLineClkSrc OBJECT-TYPE
SYNTAX INTEGER
{
localExtRemoteRcv (1),
localIntRemoteRcv (2),
localRcvRemoteInt (3),
localRcvRemoteExt (4),
localExtAutoRemoteRcv (5),
localRcvRemoteExtAuto (6),
localSysRemoteRcv (7),
localRcvRemoteSys (8),
internal (9),
external (10),
system (11),
receive (12),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The clock source of the Line port.
(5),(6) - applicable only for ASMi-24 and ASMi-50.
(7),(8) - System level Clock Source. Applicable to CQ modems."
::= {modmPrtLineEntry 2}
modmPrtLineTxLevel OBJECT-TYPE
SYNTAX INTEGER
{
n12 (1),
n9 (2),
n6 (3),
n3 (4),
p0 (5),
p4 (6),
p6 (7),
p10 (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transmit level in dBm.
pxx = positive xx = +xx
nxx = negative xx = -xx "
::= {modmPrtLineEntry 3}
modmPrtLineRxLevel OBJECT-TYPE
SYNTAX INTEGER
{
n14 (1),
n12 (2),
n10 (3),
n9 (4),
n6 (5),
n3 (6),
p0 (7),
low (8),
high (9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Rx Sensitivity in dBm.
pxx = positive xx = +xx
nxx = negative xx = -xx."
::= {modmPrtLineEntry 4}
modmPrtLineOutImp OBJECT-TYPE
SYNTAX INTEGER
{
infinite (1),
i75ohm (2),
i100ohm (3),
i120ohm (4),
i150ohm (5),
i300ohm (6),
i600ohm (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Output impedance in Ohm."
::= {modmPrtLineEntry 5}
modmPrtLineInImp OBJECT-TYPE
SYNTAX INTEGER
{
infinite (1),
i75ohm (2),
i100ohm (3),
i120ohm (4),
i150ohm (5),
i300ohm (6),
i600ohm (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Input impedance in Ohm."
::= {modmPrtLineEntry 6}
modmPrtLineCarrCntrl OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Carrier control."
::= {modmPrtLineEntry 7}
modmPrtLineRAP OBJECT-TYPE
SYNTAX INTEGER
{
private (1),
v110 (2),
v220 (3),
privateV110Enable (4),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Rate Adapting Protocol.
privateV110Enable (4)= private but enables return to v110. "
::= {modmPrtLineEntry 8}
modmPrtLineWaveLength OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
nm850 (2),
nm1300 (3),
nm780Laser (4),
nm1300Laser (5),
nm1550Laser (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wave Length of the optical Line.
notApplicable - when the modem Line is not optical.
The units are nano-meters [nm]."
::= {modmPrtLineEntry 9}
modmPrtLineCdSense OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
high (2),
low (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Carrier Detect Sense - Detection Sensitivity of Carrier Wave.
high - high sensitivity
low - low sensitivity. "
::= {modmPrtLineEntry 10}
modmPrtLineAIS OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"AIS enable/disable.
notApplicable - for modems that do not support this feature."
::= {modmPrtLineEntry 11}
modmPrtLineCoding OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
ami (2),
hdb3 (3),
b8zs (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Line Coding."
::= {modmPrtLineEntry 12}
modmPrtLineLength OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
len0p133ft (2),
len134p266ft (3),
len267p399ft (4),
len400p533ft (5),
len534p655ft (6),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the line length mask parameter used only
for T1/DSU interfaces.
len400p533ft=length range: 400ft to 533ft."
::= {modmPrtLineEntry 13}
modmPrtLineClkSrcPort OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
modem1 (2),
modem2 (3),
modem3 (4),
modem4 (5),
ds1 (6),
dte (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock Source Port.
This parameter is relevant for external clock source."
::= {modmPrtLineEntry 14}
modmPrtLineDteClkConfig OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
dceExternal (2),
dce (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the clock source of the modems, which were not selected to supply
the external clock."
::= {modmPrtLineEntry 15}
modmPrtLineMaskAlr OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
dontMask (2),
mask (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter determine whether masking or not the alarms for this line."
::= {modmPrtLineEntry 16}
-- Traps
--NOTIFICATIONS
modmSaEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for Stand Alone Modems."
::= { modmSa 0 }
modmSysEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for General Modems."
::= { modmSys 0 }
modmSAlarmTrap NOTIFICATION-TYPE
OBJECTS {modmSaStatAlarms}
STATUS current
DESCRIPTION
"The trap is sent every 5 seconds in which a change has
occurred in the status of the variables sent.
For modems containing a T1/E1 interface, dsx1LineStatus
will be sent as well in the variables, after modmSaStatAlarms.
This trap is applicable for Stand-alone modems or Agents
that are cards of a Hub."
::= { modmSaEvents 1 }
modmSLedTrap NOTIFICATION-TYPE
OBJECTS {agnLed}
STATUS current
DESCRIPTION
"The trap is sent every 5 seconds in which a change has
occurred in the state of one of the LEDs.
This trap is applicable for Stand-Alone modems or Agents
that are cards of a Hub.
'agnLed' - will include both central and remote modems:
first central, last remote."
::= { modmSaEvents 2 }
-- the following traps are for a modems-Hub or IMOD modems
modmHubConfigChange NOTIFICATION-TYPE
OBJECTS {mdlCardType, mdlSPanelType}
STATUS current
DESCRIPTION
"The trap is sent when any card of the modems Hub is inserted
or removed."
::= { modmSysEvents 3 }
modemMasterSlaveComm NOTIFICATION-TYPE
OBJECTS {modemMngLink}
STATUS current
DESCRIPTION
"This trap is applicable only for IMOD modems .
The trap is sent when communication between a Master modem
and its Slave is stopped or resumed.
'modemMngLink' includes the modemIdx."
::= { modmSysEvents 4 }
modemMasterChange NOTIFICATION-TYPE
OBJECTS {modemConfigMode, modemModeTemporary}
STATUS current
DESCRIPTION
"This trap is applicable only for IMOD modems .
The trap is sent when a modem's permanent or temporary mode
is changed.
'modemConfigMode' and 'modemModeTemporary' include the
modemIdx."
::= { modmSysEvents 5 }
mngmntControlChange NOTIFICATION-TYPE
OBJECTS {modmHubController}
STATUS current
DESCRIPTION
"This trap is applicable only for LRS-12.
The trap is sent when the Hub management controller is
changed (NMS<->Terminal)."
::= { modmSysEvents 6 }
modemInvalidParameter NOTIFICATION-TYPE
OBJECTS {modemIdx}
STATUS current
DESCRIPTION
"This trap is applicable only for IMOD cards of a Hub.
The trap is sent when an invalid parameter was Set to the
modem."
::= { modmSysEvents 7 }
modemAlarm NOTIFICATION-TYPE
OBJECTS {modemActiveAlarms}
STATUS current
DESCRIPTION
"This trap is applicable only for IMOD modems .
The trap is sent when the active alarms of an IMOD modem,
change."
::= { modmSysEvents 8 }
cardStatusChange NOTIFICATION-TYPE
OBJECTS {mdlSLed}
STATUS current
DESCRIPTION
"The trap is sent upon any change of the Leds status in the
PS, CL or IMOD cards."
::= { modmSysEvents 9 }
modemSignalingChange NOTIFICATION-TYPE
OBJECTS {modmPrtDteSignaling}
STATUS current
DESCRIPTION
"The trap is sent for any IMOD modem, when an unmasked
signal change occured in the attached variable (see
modemMaskSignaling object)."
::= { modmSysEvents 10 }
modmHubPsFail NOTIFICATION-TYPE
OBJECTS {mdlSLed}
STATUS current
DESCRIPTION
"The trap is sent when a PS card of the modems-Hub failed.
'mdlSLed' includes the mdlSIdx."
::= { modmSysEvents 11 }
modmHubIPModeChange NOTIFICATION-TYPE
OBJECTS {modmHubIpMode}
STATUS current
DESCRIPTION
"The trap is sent upon any change of modmHubIpMode parameter."
::= { modmSysEvents 12 }
modmInterfaceChange NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"The trap is sent upon any change of interfaces for a modem that
is a card of a Hub or part of it.
In order to know what changed, for each product, specific variables will
be attached. These variables will be specified in the product's spec.
For FOMi-E3/T3 and Optimux-4E1/T1-C : the trap will be sent when
the connectors card in LRS is removed/inserted."
::= { modmSysEvents 13 }
modmRackAlarms NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"The trap is applicable for LRS-52.
The trap is sent when an alarm occurs.
Attached variables are detailed in product specification."
::= { modmSysEvents 14 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\kmux.txt
--
-- RAD-KMUX MIB (Kilomux)
--Title: RAD's Kilomux PRODUCT MIB
--Version: 1.0
--Date: 29.8.96
--By: Yair Arian, Smadar Tauber and Yaira Gabay
--File: kmux.txt ver535
--
--Last update: 29-10-2007 by Smadar Tauber
kmux OBJECT IDENTIFIER ::= {radWan 6}
systemKmux OBJECT IDENTIFIER ::= {kmux 1}
generalKmux OBJECT IDENTIFIER ::= {systemKmux 1}
sysGenKmuxTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysGenKmuxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing the general Kmux parameters."
::= { generalKmux 1 }
sysGenKmuxEntry OBJECT-TYPE
SYNTAX SysGenKmuxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {sysGenConfigIdx}
::= {sysGenKmuxTable 1}
SysGenKmuxEntry ::=
SEQUENCE {
sysGenConfigIdx Integer32,
sysGenFlipIntegration INTEGER,
sysGenMlMode INTEGER,
sysGenFaType INTEGER,
sysGenLinkRecovery INTEGER,
sysGenLinkSourceClock INTEGER,
sysGenMngBwA Integer32,
sysGenMngBwB Integer32,
sysGenAutoDialSlot Integer32,
sysGenResetBypassEnable INTEGER,
sysGenRebuildFrame INTEGER
}
sysGenConfigIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Configuration number (1..255)
referred.
Value of 255 specifies the TmpCnfg (Scratch).
The write operation in this Table is valid only to the
TmpCnfg entry."
::= { sysGenKmuxEntry 1}
sysGenFlipIntegration OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1),
short (2),
long (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The parameter is relevant only for KM-2100 and only when
sysGenMlMode=redundancy, switchBackup, or priorityBumping."
::= { sysGenKmuxEntry 2}
sysGenMlMode OBJECT-TYPE
SYNTAX INTEGER { single (2),
redundancy (3),
dualLink (4),
priorityBumping(5),
switchBackup (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Main Link operation mode. Determines how many links are
used (one/two) and how they are used."
::= { sysGenKmuxEntry 3}
sysGenFaType OBJECT-TYPE
SYNTAX INTEGER { auto (2),
manual (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frame Allocation type:
auto - automatic frame allocation (by Kmux)
manual - manually configured frame allocation (by user)."
::= { sysGenKmuxEntry 4}
sysGenLinkRecovery OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
auto (2),
manual (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The parameter determines the Link Recovery mode.
The parameter is relevant only when the sysGenMlMode is either
switchBackup or priorityBumping."
::= { sysGenKmuxEntry 5}
sysGenLinkSourceClock OBJECT-TYPE
SYNTAX INTEGER { none (1),
kmxMlA (103),
kmxMlB (104)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The source clock for the links. The parameter is relevant
only for KM-2100 having a KDI or KDI/CH cards. ML-A or ML-B
are selectable only when sysGenMlMode=dual or priorityBumping."
::= { sysGenKmuxEntry 6}
sysGenMngBwA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The required management rate for ML-A, in bps. It is very important when a remote
unit is managed.
The selected value must be < ML-A Rate value.
0 = None or not applicable
800 bps = minimum value
19200 bps = maximum value"
::= { sysGenKmuxEntry 7}
sysGenMngBwB OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The required management rate for ML-B, in bps. It is very important when a remote
unit is managed.
The selected value must be < ML-B Rate value.
0 = None or not applicable
800 bps = minimum value
19200 bps = maximum value"
::= { sysGenKmuxEntry 8}
sysGenAutoDialSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the IO-SLOTs that can be used to initiate Automatic
DialUp.
This field will be applicable when KML.10 is a ML and its
prtIsdnSwitchMode=auto.
Each IO Slot is represented by a bit: 11 .............0
MSB(IO12) LSB(IO1)
bit 0 (LSB) kmxIO1: '1'- used
'0'- not used
bit 1 kmxIO2: '1'- used
'0'- not used
bit 2 kmxIO3: '1'- used
. '0'- not used
.
bit 11(MSB) kmxIO12: '1'- used
'0'- not used
The value will be: SUM of [2**n] ; n=bit number."
::= { sysGenKmuxEntry 9}
sysGenResetBypassEnable OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable Reset Bypass operation when a KDI card exists
and one of its links failed.
notApplicable - when no KDI card exists in the Hub."
::= { sysGenKmuxEntry 10}
sysGenRebuildFrame OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
automatically (2),
manually (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"How to rebuild frame (when a CH is connected/disconnected):
automatically - immediately, by automatic frame allocation (by Kmux)
manually - manually configured frame allocation (by user), or Rebuild
Frame command to ML card."
::= { sysGenKmuxEntry 11}
sysGenLinkRecoveryCmd OBJECT-TYPE
SYNTAX INTEGER {
noOp (1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Command to recover from ML failure.
When 'on', the agent will perform manual link recovery and
reset the variable to 'off'.
The conditions for this action are:
sysGenMlMode= priorityBumping or switchBackup and also
sysGenLinkRecovery=manual(3)."
::= { generalKmux 2}
sysGenFlipMlCmd OBJECT-TYPE
SYNTAX INTEGER {
noOp (1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Command to flip the ML when sysGenMlMode=redundancy.
When 'on', the agent will flip the ML and reset
the variable to 'off'."
::= { generalKmux 3}
sysGenMonitorChannel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The variable specifies the channel to be monitored and
presented on the front panel LEDs. The channel will be
specified according to: Slot*100+Ch.
0 - no monitoring."
::= { generalKmux 4}
statusKmux OBJECT IDENTIFIER ::= {systemKmux 2}
sysStatusOnLineML OBJECT-TYPE
SYNTAX INTEGER { both (1),
kmxMlA (103),
kmxMlB (104)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The main links which are online."
::= { statusKmux 1}
sysKmuxStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A BIT string indicating the system status as follows
On - the bit is set to '1':
Bit 0 (LSB): Alarm Relay.
Bit 1: SP param.
Off- Configure the SP port from the database
On - Default parameters (9600bps, 8 data bits,
no parity, one stop bit).
Bit 2: DBinit.
The status of the dip switch in the Common Logic Card.
Off- Configuration parameters were determined by the
user.
On - Default configuration parameters are loaded on
mux power-on.
Bit 3: DownloadBw.
Off - Disable in-band management.
On - Enable in-band management.
Bit 4 (MSB): Passwd.
Off - No password is required.
On - Password is required.
Example: 8 (10000) means Passwd.=On and all the others off."
::= { statusKmux 2}
sysKmuxOffset OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
off (2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"'on' - slots 1..4 of KM-2104 match slots 11..14 of KM-2100.
'off'- slots 1..4 of KM-2104 match slots 7..10 of KM-2100.
notApplicable - for KM-2100."
::= { statusKmux 3}
backupKmux OBJECT IDENTIFIER ::= {systemKmux 3}
sysBackupTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysBackupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing the backup parameters."
::= { backupKmux 1 }
sysBackupEntry OBJECT-TYPE
SYNTAX SysBackupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {sysBackupConfigIdx}
::= {sysBackupTable 1}
SysBackupEntry ::=
SEQUENCE {
sysBackupConfigIdx Integer32,
sysBackupDatabase INTEGER,
sysBackupMode INTEGER,
sysBackupDialTimeout INTEGER,
sysBackupOptions INTEGER
}
sysBackupConfigIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Configuration number (1..255)
referred.
Value of 255 specifies the TmpCnfg (Scratch)."
::= { sysBackupEntry 1}
sysBackupDatabase OBJECT-TYPE
SYNTAX INTEGER { onLine (2),
alternate(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines the database to switch to, when ML recovery occurs."
::= { sysBackupEntry 2}
sysBackupMode OBJECT-TYPE
SYNTAX INTEGER { isdn(2),
pstn(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"isdn - for connection to ISDN network.
pstn - for connection to PSTN network."
::= { sysBackupEntry 3}
sysBackupDialTimeout OBJECT-TYPE
SYNTAX INTEGER { sec30 (2),
sec45 (3),
sec60 (4),
sec120(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The dial timeout in seconds (when backup is attempted)."
::= { sysBackupEntry 4}
sysBackupOptions OBJECT-TYPE
SYNTAX INTEGER { noBackup (2),
line (3),
path (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Backup options:
noBackup - No backup is applicable
line - Line Data backup
path - Line Mng backup ."
::= { sysBackupEntry 5}
sysBackupAgendaTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysBackupAgendaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing the backup schedule. It is possible to
define 4 different time zone schedules per day of the week."
::= { backupKmux 2 }
sysBackupAgendaEntry OBJECT-TYPE
SYNTAX SysBackupAgendaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {sysBackupCfgIdx,sysBackupDay,sysBackupZone}
::= {sysBackupAgendaTable 1}
SysBackupAgendaEntry ::=
SEQUENCE {
sysBackupCfgIdx INTEGER,
sysBackupDay INTEGER,
sysBackupZone INTEGER,
sysBackupEndTime DisplayString,
sysBackupStatus INTEGER
}
sysBackupCfgIdx OBJECT-TYPE
SYNTAX INTEGER
{
active (1),
temporary (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Configuration number (1,255)
referred.
Write operation for the table entries is allowed only to
the temporary configuration (255)."
::= { sysBackupAgendaEntry 1}
sysBackupDay OBJECT-TYPE
SYNTAX INTEGER {sunday (1),
monday (2),
tuesday (3),
wednesday(4),
thursday (5),
friday (6),
saturday (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Day of the week."
::= { sysBackupAgendaEntry 2}
sysBackupZone OBJECT-TYPE
SYNTAX INTEGER {zone1(1),
zone2(2),
zone3(3),
zone4(4),
zone5(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time zone."
::= { sysBackupAgendaEntry 3}
sysBackupEndTime OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The end time for this time zone. The format is HH:MM. For
example 23:59.
For Zone 4, End Time = 23:59 (constant)."
::= { sysBackupAgendaEntry 4}
sysBackupStatus OBJECT-TYPE
SYNTAX INTEGER { enable (1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable this backup schedule entry."
::= { sysBackupAgendaEntry 5}
frameAllocationKmux OBJECT IDENTIFIER ::= {systemKmux 4}
sysFrameAllocationTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysFrameAllocationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table for manually configuring the frame allocation.
The table will contain always all the programmed cards'
ports. sysFaNumOfBits"
::= { frameAllocationKmux 1 }
sysFrameAllocationEntry OBJECT-TYPE
SYNTAX SysFrameAllocationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {sysFaConfigIdx, sysFaLink, sysFaPrt}
::= {sysFrameAllocationTable 1}
SysFrameAllocationEntry ::=
SEQUENCE {
sysFaConfigIdx Integer32,
sysFaLink INTEGER,
sysFaPrt Integer32,
sysFaStartingBit Integer32,
sysFaNumOfBits Integer32
}
sysFaConfigIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Configuration number (1..255)
referred.
Value of 255 specifies the TmpCnfg (Scratch).
Write operation for the table entries is allowed only to
Config=255."
::= { sysFrameAllocationEntry 1}
sysFaLink OBJECT-TYPE
SYNTAX INTEGER {
kmxMlA (103),
kmxMlB (104)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The main link on which frame allocation is done."
::= { sysFrameAllocationEntry 2}
sysFaPrt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Frame Allocation (FA) port.
The ports will be specified by:
Slot*100+Ch.
- for Bypass of KDI or KDI/CH the port will be:
Slot*100+11 (internal-1=non-existent port ; just for use
of the same MIB table)
- for all the programmed cards, there will be an artificial
port entry that will represent the card, in order to
specify the Control Signal Bits that are at card level:
Slot*100+0 . "
::= { sysFrameAllocationEntry 3}
sysFaStartingBit OBJECT-TYPE
SYNTAX Integer32 (0..239)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The data starting bit for the channel.
- for Bypass of KDI or KDI/CH, this will be the Starting Bit
of the Bypass Window on the specific sysFaLink.
- for Control Signals of a card ( sysFaPrt=Slot*100+0)
this will be the Starting Bit of the Control Signals of the
card."
::= { sysFrameAllocationEntry 4}
sysFaNumOfBits OBJECT-TYPE
SYNTAX Integer32 (0..239)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The data size in number of bits for the channel.
- for Bypass of KDI or KDI/CH, this will be the Bypass Window
size. In this case, this value must be the same for both
MLs.
- for Control Signals of a card ( sysFaPrt=Slot*100+0)
this will be the number of Control Signal Bits of the
card."
::= { sysFrameAllocationEntry 5}
-- Disconnect Supervision Event Table.
-- This table contains all the Disconnect Supervision Events
-- that occurred on the KVF.6 and KVF.8 cards of the KM.
sysDisconnectSupervisionEventTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysDisconnectSupervisionEventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Disconnect Supervision Event table."
::= {systemKmux 5}
sysDisconnectSupervisionEventEntry OBJECT-TYPE
SYNTAX SysDisconnectSupervisionEventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table."
INDEX { sysDsEventIdx }
::= { sysDisconnectSupervisionEventTable 1}
SysDisconnectSupervisionEventEntry ::=
SEQUENCE {
sysDsEventIdx Integer32,
sysDsEventSlot INTEGER,
sysDsEventTS Integer32,
sysDsEventDescr DisplayString,
sysDsEventDateAndTime DisplayString
}
sysDsEventIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique Event Index."
::= { sysDisconnectSupervisionEventEntry 1}
sysDsEventSlot OBJECT-TYPE
SYNTAX INTEGER
{
kmxIO1 (107),
kmxIO2 (108),
kmxIO3 (109),
kmxIO4 (110),
kmxIO5 (111),
kmxIO6 (112),
kmxIO7 (113),
kmxIO8 (114),
kmxIO9 (115),
kmxIO10(116),
kmxIO11(117),
kmxIO12(118)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique number of the slot position,
where the KVF.6 or KVF.8 card is inserted,
and the Disconnect Supervision Event occurred."
::= { sysDisconnectSupervisionEventEntry 2}
sysDsEventTS OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines the Time Slot number,
where the Disconnect Supervision Event occurred."
::= { sysDisconnectSupervisionEventEntry 3}
sysDsEventDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines the Description
of the Disconnect Supervision Event."
::= { sysDisconnectSupervisionEventEntry 4}
sysDsEventDateAndTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines the Date and Time,
when the Disconnect Supervision Event occurred.
It will be displayed in the following format: YYYY-MM-DD HH:MM:SS."
::= { sysDisconnectSupervisionEventEntry 5}
mdlKmux OBJECT IDENTIFIER ::= {kmux 2}
mdlKmxTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlKmxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { mdlKmux 2 }
mdlKmxEntry OBJECT-TYPE
SYNTAX MdlKmxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mdlKmxConfigIdx, mdlKmxSlotIdx }
::= { mdlKmxTable 1}
MdlKmxEntry ::=
SEQUENCE {
mdlKmxConfigIdx Integer32,
mdlKmxSlotIdx INTEGER,
mdlKmxOperatedMl INTEGER,
mdlKmxMlAtoMlBPrio INTEGER,
mdlKmxMlBtoMlAPrio INTEGER,
mdlKmxOutSrvMethod INTEGER,
mdlKmxV54Config INTEGER,
mdlKmxTiming INTEGER,
mdlKmxIsdnDisconnectCause Unsigned32,
mdlKmxIsdnCallStatus INTEGER,
mdlKmxIsdnLayer1State INTEGER,
mdlKmxIsdnLayer2State INTEGER
}
mdlKmxConfigIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Configuration number (1..255)
referred.
Value of 255 specifies the TmpCnfg (Scratch).
Write operation for the table entries is allowed only to
Config=255."
::= { mdlKmxEntry 1}
mdlKmxSlotIdx OBJECT-TYPE
SYNTAX INTEGER
{
kmxPsA (101),
kmxPsB (102),
kmxMlA (103),
kmxMlB (104),
kmxCl (105),
kmxOpt (106),
kmxIO1 (107),
kmxIO2 (108),
kmxIO3 (109),
kmxIO4 (110),
kmxIO5 (111),
kmxIO6 (112),
kmxIO7 (113),
kmxIO8 (114),
kmxIO9 (115),
kmxIO10(116),
kmxIO11(117),
kmxIO12(118)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique number of the slot position
in which the module is inserted."
::= { mdlKmxEntry 2}
mdlKmxOperatedMl OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
kmxMlA (103),
kmxMlB (104),
kmxMlAandMlB (119) -- for KVF.6 and KMBE/NEW
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The main link for this card.
The field is relevant only for ML modes of Dual, Priority
Bumping and Switched Backup."
::= { mdlKmxEntry 3}
mdlKmxMlAtoMlBPrio OBJECT-TYPE
SYNTAX INTEGER {notApplicable(1),
low (2),
high (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ML-A to ML-B Priority.
The field is relevant only for ML modes of Priority Bumping
and Switched Backup."
::= { mdlKmxEntry 4}
mdlKmxMlBtoMlAPrio OBJECT-TYPE
SYNTAX INTEGER {notApplicable(1),
low (2),
high (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ML-B to ML-A Priority.
The field is relevant only for ML modes of Priority Bumping."
::= { mdlKmxEntry 5}
mdlKmxOutSrvMethod OBJECT-TYPE
SYNTAX INTEGER {notApplicable(1),
idleBusy (2),
forcedIdle (3),
busyIdle (4),
forcedBusy (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Out of service method. For KVC.1 and KVC.1M all values are
applicable.
For KVC.2, KVC.3, KVF.1, KVF.3, KVF.4: only forcedIdle and
forcedBusy are applicable."
::= { mdlKmxEntry 6}
mdlKmxV54Config OBJECT-TYPE
SYNTAX INTEGER {notApplicable(1),
dceDce (2),
dceDte (3),
dteDce (4),
dteDte (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Relevant only for KLS.1/New card."
::= { mdlKmxEntry 7}
mdlKmxTiming OBJECT-TYPE
SYNTAX INTEGER {notApplicable(1),
lt (2),
nt (3),
te (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Applicable only for KHSU.1, KHSU.2, KVF.4/S0, KVC.3/S0 cards.
lt - local timing
nt - network timing
te - terminal equipment "
::= { mdlKmxEntry 8}
mdlKmxIsdnDisconnectCause OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the cause of the ISDN Disconnection for
the card installed in the specific slot position. The value can be
0..255. The numeric values have a well known meaning for ISDN experts."
::= { mdlKmxEntry 9 }
mdlKmxIsdnCallStatus OBJECT-TYPE
SYNTAX INTEGER
{noCallIndicator(1),
dialing (2),
connected (3),
disconnecting (4),
disconnected (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the current ISDN Call Status for
the card installed in the specific slot position."
::= { mdlKmxEntry 10}
mdlKmxIsdnLayer1State OBJECT-TYPE
SYNTAX INTEGER
{disconnected (2),
connected (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the ISDN Layer 1 State for
the card installed in the specific slot position."
::= { mdlKmxEntry 11}
mdlKmxIsdnLayer2State OBJECT-TYPE
SYNTAX INTEGER
{disconnected (2),
connected (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the ISDN Layer 2 State for
the card installed in the specific slot position."
::= { mdlKmxEntry 12}
mdlKvf5PbxTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlKvf5PbxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Parameters specific to KVF.5, KVF.6 and KVF.8 PBX cards."
::= { mdlKmux 3 }
mdlKvf5PbxEntry OBJECT-TYPE
SYNTAX MdlKvf5PbxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mdlKvf5PbxConfigIdx, mdlKvf5PbxSlotIdx }
::= { mdlKvf5PbxTable 1}
MdlKvf5PbxEntry ::=
SEQUENCE {
mdlKvf5PbxConfigIdx Integer32,
mdlKvf5PbxSlotIdx INTEGER,
mdlKvf5PbxSig INTEGER,
mdlKvf5PbxSigMode INTEGER,
mdlKvf5PbxTsAssign INTEGER,
mdlKvf5PbxCcsTs Integer32,
mdlKvf5PbxOos INTEGER,
mdlKvf5PbxSigTxPbx INTEGER,
mdlKvf5PbxSigRxPbx INTEGER,
mdlKvf5PbxDefABCD OCTET STRING,
mdlKvf5PbxFramerSlot INTEGER,
mdlKvf5PbxCcsRate INTEGER,
mdlKvf5PbxTxAbcdBit OCTET STRING,
mdlKvf5PbxHdlcCrc INTEGER
}
mdlKvf5PbxConfigIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Configuration number (1..255)
referred.
Value of 255 specifies the TmpCnfg (Scratch).
Write operation for the table entries is allowed only to
Config=255."
::= { mdlKvf5PbxEntry 1}
mdlKvf5PbxSlotIdx OBJECT-TYPE
SYNTAX INTEGER
{
kmxIO1 (107),
kmxIO2 (108),
kmxIO3 (109),
kmxIO4 (110),
kmxIO5 (111),
kmxIO6 (112),
kmxIO7 (113),
kmxIO8 (114),
kmxIO9 (115),
kmxIO10(116),
kmxIO11(117),
kmxIO12(118)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique number of the slot position
in which the module is inserted."
::= { mdlKvf5PbxEntry 2}
mdlKvf5PbxSig OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
a (2),
aANDb(3),
b (4),
ccs (5),
cas (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Signaling type.
When 'mdlKvf5PbxSig' is valid, 'mdlKvf5PbxSigTxPbx' and 'mdlKvf5PbxSigRxPbx'
are not valid.
mdlKvf5PbxSig - is supported by KVF.5 OLD SW ver and KVF.6 card.
mdlKvf5PbxSigTxPbx and mdlKvf5PbxSigRxPbx - are supported by KVF.5 NEW SW ver
and KVF.6."
::= { mdlKvf5PbxEntry 3}
mdlKvf5PbxSigMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
direct (2),
inverse(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Signaling Mode."
::= { mdlKvf5PbxEntry 4}
mdlKvf5PbxTsAssign OBJECT-TYPE
SYNTAX INTEGER {
s1s2s3s4 (2),
s5s6s7s8 (3),
s9s10s11s12 (4),
s13s14s15s16 (5),
s17s18s19s20 (6),
s21s22s23s24 (7),
s13s14s15s17 (8),
s18s19s20s21 (9),
s22s23s24s25(10),
s26s27s28s29(11),
s30s31 (12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ts Assignment group. Each KVF.5 card of the Mux should have
a different value.
For KVF.5/E1 values: 2,3,4,8,9,10,11,12 are applicable.
For KVF.5/T1 values: 2,3,4,5,6,7 are applicable."
::= { mdlKvf5PbxEntry 5}
mdlKvf5PbxCcsTs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CCS TS of the KVF.5/T1/E1 and KVF.6/T1/E1 card.
It is applicable for Kmux KVF.5 Framer cards and KVF.6 cards
when mdlKvf5PbxSig=ccs.
Valid values:
1..24 - CCS TS of T1
1..31 - CCS TS of E1
255 - notApplicable (for agents that do not support this
feature or for irrelevant cards)
Other values are invalid.
The value selected should not be the same as one of the TSs assigned for
any card of the same group via mdlKvf5PbxTsAssign."
::= { mdlKvf5PbxEntry 6}
mdlKvf5PbxOos OBJECT-TYPE
SYNTAX INTEGER
{
notSupported (2),
forcedIdle (3),
forcedBusy (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"'idle' = '0' = on-hook, idle state
'busy' = '1' = off-hook, busy state
'forcedIdle' = SP = both A and B signaling bits are forced
to '0' during out-of-service periods.
'forcedBusy' = MK = both A and B signaling bits are forced
to '1' during out-of-service periods.
- for T1: '0'=0 ; '1'=1
- for E1: '0'=1 ; '1'=0 "
::= { mdlKvf5PbxEntry 7}
mdlKvf5PbxSigTxPbx OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
a (2),
b (3),
aANDb (4),
crossAandB (5),
ccs (6),
aEqualsB (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TxPbx signaling means transmit signaling from KM to PBX (KM-->PBX)
When 'mdlKvf5PbxSigTxPbx' is valid, 'mdlKvf5PbxSig' field is not valid.
mdlKvf5PbxSig - is supported by KVF.5 OLD SW ver.
mdlKvf5PbxSigTxPbx and mdlKvf5PbxSigRxPbx - are supported by KVF.5 NEW SW ver."
::= { mdlKvf5PbxEntry 8}
mdlKvf5PbxSigRxPbx OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
a (2),
b (3),
aANDb (4),
ccs (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RxPbx signaling means receive signaling from PBX to KM (PBX-->KM-->KM)
When 'mdlKvf5PbxSigRxPbx' is valid, 'mdlKvf5PbxSig' field is not valid.
mdlKvf5PbxSig - is supported by KVF.5 OLD SW ver.
mdlKvf5PbxSigTxPbx and mdlKvf5PbxSigRxPbx - are supported by KVF.5 NEW SW ver."
::= { mdlKvf5PbxEntry 9}
mdlKvf5PbxDefABCD OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..1))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines what KM will send for the ABCD Bits that
are not 'filled' by the dynamic signaling. This field is applicable
only for signaling transmit to PBX ('mdlKvf5PbxSigTxPbx').
For KVF.5 cards: valid range (00 - 0F HEX) - ABCD Bits."
::= { mdlKvf5PbxEntry 10}
mdlKvf5PbxFramerSlot OBJECT-TYPE
SYNTAX INTEGER
{
kmxIO1 (107),
kmxIO2 (108),
kmxIO3 (109),
kmxIO4 (110),
kmxIO5 (111),
kmxIO6 (112),
kmxIO7 (113),
kmxIO8 (114),
kmxIO9 (115),
kmxIO10(116),
kmxIO11(117),
kmxIO12(118),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Framer's slot number this card belongs to.
Several cards having the same mdlKvf5PbxFramerSlot value, work together
as a group."
::= { mdlKvf5PbxEntry 11}
mdlKvf5PbxCcsRate OBJECT-TYPE
SYNTAX INTEGER
{
notConnected(1),
bps4800(2),
bps6400(3),
bps9600(4),
bps12800(5),
bps16000(6),
bps19200(7),
bps32000(8),
bps64000(9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines the Ccs speed - for KVF.6 and KVF.5 cards."
::= { mdlKvf5PbxEntry 12}
mdlKvf5PbxTxAbcdBit OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only for KVF.6 and KVF.8 cards, when mdlKvf5PbxSig=cas(6).
It represents 4 parameters, by 2 Octets :
D Bit Code-MSB nibble,
C Bit Code- nibble,
B Bit Code- nibble,
A Bit Code-LSB nibble.
Each of A,B,C,D Bit Code nibble represents:
0 hex = 0000 = 0
1 hex = 0001 = 1
2 hex = 0010 = A bit
3 hex = 0011 = B bit
4 hex = 0100 = C bit
5 hex = 0101 = D bit
6 hex = 0110 = A bit inverse
7 hex = 0111 = B bit inverse
8 hex = 1000 = C bit inverse
9 hex = 1001 = D bit inverse
A-E hex - not used (invalid values)
When the object is not applicable, 0 Octets will be sent."
::= { mdlKvf5PbxEntry 13}
mdlKvf5PbxHdlcCrc OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
crc16(2),
crc32(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines the CRC type of HDLC protocol, that CCS signaling
is working with. Applicable for KVF.6 cards when Signaling
is CCS (only)."
::= { mdlKvf5PbxEntry 14}
-- Disconnect Supervision (Ds) Table.
-- Applicable for KVF.6 and KVF.8 cards.
mdlDisconnectSupervisionTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlDisconnectSupervisionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Disconnect Supervision table."
::= { mdlKmux 4 }
mdlDisconnectSupervisionEntry OBJECT-TYPE
SYNTAX MdlDisconnectSupervisionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table."
INDEX { mdlDsConfigIdx, mdlDsSlotIdx }
::= { mdlDisconnectSupervisionTable 1}
MdlDisconnectSupervisionEntry ::=
SEQUENCE {
mdlDsConfigIdx Integer32,
mdlDsSlotIdx INTEGER,
mdlDs INTEGER,
mdlDsUserLoc INTEGER,
mdlDsMode INTEGER,
mdlDsSilence Integer32,
mdlDsClrFwSig OCTET STRING,
mdlDsAnswerSig OCTET STRING,
mdlDsClrBwSig OCTET STRING,
mdlDsFbtLowFreq Integer32,
mdlDsFbtHighFreq Integer32,
mdlDsFbtTimeOn1 Integer32,
mdlDsFbtTimeOff1 Integer32,
mdlDsFbtTimeOn2 Integer32,
mdlDsFbtTimeOff2 Integer32,
mdlDsFbtLowFreqLevel Integer32,
mdlDsFbtHighFreqLevel Integer32
}
mdlDsConfigIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Configuration number (1..255)
referred.
Value of 255 specifies the TmpCnfg (Scratch).
Write operation for the table entries is allowed only to
Config=255."
::= { mdlDisconnectSupervisionEntry 1}
mdlDsSlotIdx OBJECT-TYPE
SYNTAX INTEGER
{
kmxIO1 (107),
kmxIO2 (108),
kmxIO3 (109),
kmxIO4 (110),
kmxIO5 (111),
kmxIO6 (112),
kmxIO7 (113),
kmxIO8 (114),
kmxIO9 (115),
kmxIO10(116),
kmxIO11(117),
kmxIO12(118)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique number of the slot position
in which the module is inserted."
::= { mdlDisconnectSupervisionEntry 2}
mdlDs OBJECT-TYPE
SYNTAX INTEGER
{
disable (1),
remoteDisconnect (2),
remoteDisconnectAndSilence (3),
silenceOnly (4),
fastBusyOnly (5),
silenceOrFastBusy (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines which terms will cause disconnection of call.
disable = the Disconnect Supervision feature is disabled. In this case,
all other objects of this table are irrelevant.
Remote Sanity -
If mdlDsUserLoc = Remote Location , the valid values are :
disable(1), silenceOnly(4), fastBusyOnly(5), silenceOrFastBusy(6).
If mdlDsUserLoc = Local , the valid values are
disable(1), remoteDisconnect(2), remoteDisconnectAndSilence (3)."
::= { mdlDisconnectSupervisionEntry 3}
mdlDsUserLoc OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
remote (2),
local (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User located in local or remote station.
Local station will disconnect the call actually if needed.
Applicable only if Disconnect Supervision (mdlDs) is different from disable.
Should be a Sanity check between the mdlDs and the mdlDsUserLoc parameters (see mdlDs)."
::= { mdlDisconnectSupervisionEntry 4}
mdlDsMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
reportOnly (2),
disconnect (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the action, which will be done after remote disconnect occurred.
This object is relevant only when mdlDsUserLoc = local(3).
Applicable only if Disconnect Supervision (mdlDs) is different from disable
AND User Location (mdlDsUserLoc) = local(3)."
::= { mdlDisconnectSupervisionEntry 5}
mdlDsSilence OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the silence period needed for an indication (seconds).
Applicable only if Disconnect Supervision (mdlDs) is different from disable
AND includes 'Silence', i.e. is one of the following:
remoteDisconnectAndSilence(3), silenceOnly(4), silenceOrFastBusy(6).
Valid values: 0,20,40..(every 20 seconds)..300, 0 = notApplicable.
notApplicable = silence disabled when mdlDs doesn't include 'silence'."
::= { mdlDisconnectSupervisionEntry 6}
mdlDsClrFwSig OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Clear FWD Signal (A,B,C,D bits) for KVF.6 cards.
This object is an indication of Near PBX to the Far PBX,
that it wants to disconnect the call.
Applicable only if Disconnect Supervision (mdlDs) is different from disable.
Applicable only for KVF.6 cards.
It represents 4 parameters, by an Octet:
( Bit 7 = MSB, Bit 0 = LSB )
D Bit - bits 6,7 of the MSB nibble,
C Bit - bits 4,5 of the MSB nibble,
B Bit - bits 2,3 of the LSB nibble,
A Bit - bits 0,1 of the LSB nibble.
For each of A,B,C,D Bits:
00 = 0,
01 = 1,
10 = reserved,
11 = x.
For A,B Bits - only one of them can be 'x' (not both at the same time).
For C,D Bits - 'x' won't be in use.
When the object is not applicable, a 0 Octet will be sent."
::= { mdlDisconnectSupervisionEntry 7}
mdlDsAnswerSig OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Clear FWD Signal (A,B,C,D bits) for KVF.6 cards.
This object is an indication of Near PBX to the Far PBX,
taht a call is present now on the line.
Applicable only if Disconnect Supervision (mdlDs) is different from disable.
Applicable only for KVF.6 cards.
It represents 4 parameters, by an Octet:
( Bit 7 = MSB, Bit 0 = LSB )
D Bit - bits 6,7 of the MSB nibble,
C Bit - bits 4,5 of the MSB nibble,
B Bit - bits 2,3 of the LSB nibble,
A Bit - bits 0,1 of the LSB nibble.
For each of A,B,C,D Bits:
00 = 0,
01 = 1,
10 = reserved,
11 = x.
For A,B Bits - only one of them can be 'x' (not both at the same time).
For C,D Bits - 'x' won't be in use.
When the object is not applicable, a 0 Octet will be sent."
::= { mdlDisconnectSupervisionEntry 8}
mdlDsClrBwSig OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Clear FWD Signal (A,B,C,D bits) for KVF.6 cards.
This object is an indication of Far PBX to the Near PBX,
that the call was disconnected (on the Far side).
Applicable only if Disconnect Supervision (mdlDs) is different from disable.
Applicable only for KVF.6 cards.
It represents 4 parameters, by an Octet:
( Bit 7 = MSB, Bit 0 = LSB )
D Bit - bits 6,7 of the MSB nibble,
C Bit - bits 4,5 of the MSB nibble,
B Bit - bits 2,3 of the LSB nibble,
A Bit - bits 0,1 of the LSB nibble.
For each of A,B,C,D Bits:
00 = 0,
01 = 1,
10 = reserved,
11 = x.
For A,B,C,D Bits - 'x' won't be in use.
When the object is not applicable, a 0 Octet will be sent."
::= { mdlDisconnectSupervisionEntry 9}
mdlDsFbtLowFreq OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"First frequency in Fast Busy Tone (Fbt) combination (Hz).
Valid values: 0..4000,4095. 4095 = notApplicable.
Available only if Disconnect Supervision (mdlDs) is different from disable
AND includes 'Tones' (Fast Busy), i.e. is one of the following:
fastBusyOnly(5), silenceOrFastBusy(6)."
::= { mdlDisconnectSupervisionEntry 10}
mdlDsFbtHighFreq OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Second frequency in Fast Busy Tone (Fbt) combination (Hz).
Valid values: 0..4000,4095. 4095 = notApplicable.
Available only if Disconnect Supervision (mdlDs) is different from disable
AND includes 'Tones' (Fast Busy), i.e. is one of the following:
fastBusyOnly(5), silenceOrFastBusy(6)."
::= { mdlDisconnectSupervisionEntry 11}
mdlDsFbtTimeOn1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Time On 1 cadence (in msec).
Valid values: 0,10,20..(every 10 msec)..10000,10230.
0 = disable, 10230 = notApplicable.
Available only if Disconnect Supervision (mdlDs) is different from disable
AND includes 'Tones' (Fast Busy), i.e. is one of the following:
fastBusyOnly(5), silenceOrFastBusy(6)."
::= { mdlDisconnectSupervisionEntry 12}
mdlDsFbtTimeOff1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Time Off 1 cadence (in msec).
Valid values: 0,10,20..(every 10 msec)..10000,10230.
0 = disable, 10230 = notApplicable.
Available only if Disconnect Supervision (mdlDs) is different from disable
AND includes 'Tones' (Fast Busy), i.e. is one of the following:
fastBusyOnly(5), silenceOrFastBusy(6)."
::= { mdlDisconnectSupervisionEntry 13}
mdlDsFbtTimeOn2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Time On 2 cadence (in msec).
Valid values: 0,10,20..(every 10 msec)..10000,10230.
0 = disable, 10230 = notApplicable.
Available only if Disconnect Supervision (mdlDs) is different from disable
AND includes 'Tones' (Fast Busy), i.e. is one of the following:
fastBusyOnly(5), silenceOrFastBusy(6)."
::= { mdlDisconnectSupervisionEntry 14}
mdlDsFbtTimeOff2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Time Off 2 cadence (in msec).
Valid values: 0,10,20..(every 10 msec)..10000,10230.
0 = disable, 10230 = notApplicable.
Available only if Disconnect Supervision (mdlDs) is different from disable
AND includes 'Tones' (Fast Busy), i.e. is one of the following:
fastBusyOnly(5), silenceOrFastBusy(6)."
::= { mdlDisconnectSupervisionEntry 15}
mdlDsFbtLowFreqLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"First frequency level for Fast Busy Tone (Fbt) in dBm units.
Valid values: -32..31.
Available only if Disconnect Supervision (mdlDs) is different from disable
AND includes 'Tones' (Fast Busy), i.e. is one of the following:
fastBusyOnly(5), silenceOrFastBusy(6)."
::= { mdlDisconnectSupervisionEntry 16}
mdlDsFbtHighFreqLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Second frequency level for Fast Busy Tone (Fbt) in dBm units.
Valid values: -32..31.
Available only if Disconnect Supervision (mdlDs) is different from disable
AND includes 'Tones' (Fast Busy), i.e. is one of the following:
fastBusyOnly(5), silenceOrFastBusy(6)."
::= { mdlDisconnectSupervisionEntry 17}
prtKmux OBJECT IDENTIFIER ::= {kmux 3}
prtMainLink OBJECT IDENTIFIER ::= {prtKmux 1}
prtMlFrameStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtMlFrameStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Frame diagnostics for the main links."
::= { prtMainLink 1 }
prtMlFrameStatsEntry OBJECT-TYPE
SYNTAX PrtMlFrameStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtMlFrameIdx }
::= { prtMlFrameStatsTable 1}
PrtMlFrameStatsEntry ::=
SEQUENCE {
prtMlFrameIdx Integer32,
prtMlFrameSlt INTEGER,
prtMlBitWeight INTEGER,
prtMlDataUsage Integer32,
prtMlControlSig Integer32,
prtMlDownload Integer32,
prtMlSync Integer32,
prtMlTotalUsage Integer32,
prtMlTotalFree Integer32
}
prtMlFrameIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The prtGenPrtIdx index of this link.
Slot*100+1."
::= { prtMlFrameStatsEntry 1}
prtMlFrameSlt OBJECT-TYPE
SYNTAX INTEGER
{
kmxMlA (103),
kmxMlB (104)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify the slot
where the ML card is inserted."
::= { prtMlFrameStatsEntry 2}
prtMlBitWeight OBJECT-TYPE
SYNTAX INTEGER
{
bps400 (1),
bps800 (2),
bps1600 (3),
bps3200 (4),
bps6400 (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Bit Weight [bps/bit] used for
the selected prtMlFrameSlt. The Bit Weight is according to
the ML Speed."
::= { prtMlFrameStatsEntry 3}
prtMlDataUsage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Data usage in [bits].
In order to convert it to 'bps' units, the 'bits' should be multiplied
by prtMlBitWeight value."
::= { prtMlFrameStatsEntry 4}
prtMlControlSig OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Control Signals usage of the ML in [bits].
In order to convert it to 'bps' units, the 'bits' should be multiplied
by prtMlBitWeight value."
::= { prtMlFrameStatsEntry 5}
prtMlDownload OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Download bandwidth usage of the ML in [bits].
In order to convert it to 'bps' units, the 'bits' should be multiplied
by prtMlBitWeight value."
::= { prtMlFrameStatsEntry 6}
prtMlSync OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sync bandwidth usage of the ML in [bits].
In order to convert it to 'bps' units, the 'bits' should be multiplied
by prtMlBitWeight value."
::= { prtMlFrameStatsEntry 7}
prtMlTotalUsage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total bandwidth usage of the ML in [bits].
In order to convert it to 'bps' units, the 'bits' should be multiplied
by prtMlBitWeight value."
::= { prtMlFrameStatsEntry 8}
prtMlTotalFree OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Free bandwidth of the ML in [bits].
In order to convert it to 'bps' units, the 'bits' should be multiplied
by prtMlBitWeight value."
::= { prtMlFrameStatsEntry 9}
prtMlTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtMlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Parameters for the main links.
KML.1 - KML.6, KML.7(T1), KML.8(E1), KML.10(ISDN) and
KML.F(KML.11 Fiber-optic)."
::= { prtMainLink 2 }
prtMlEntry OBJECT-TYPE
SYNTAX PrtMlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtMlCnfgIdx, prtMlIdx }
::= { prtMlTable 1}
PrtMlEntry ::=
SEQUENCE {
prtMlCnfgIdx Integer32,
prtMlIdx Integer32,
prtMlSlt INTEGER,
prtMlTiming INTEGER,
prtMlBufferSize INTEGER,
prtMlDsrCts INTEGER,
prtMlSpeed INTEGER,
prtMlStartTS Integer32,
prtMlBypassTs16 INTEGER,
prtMlCallMode INTEGER,
prtMlBondingEnable INTEGER
}
prtMlCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
Write operation for the table entries is allowed only to
Config=255. "
::= { prtMlEntry 1}
prtMlIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The prtGenPrtIdx index of this link.
Slot*100+1 ."
::= { prtMlEntry 2}
prtMlSlt OBJECT-TYPE
SYNTAX INTEGER
{
kmxMlA (103),
kmxMlB (104)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify the slot where
the ML card is inserted in."
::= { prtMlEntry 3}
prtMlTiming OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
dte (2),
dce (3),
eDce (4),
int (5),
lbt (6),
adaptive (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The clock source for this link.
For KML.1-KML.4, valid values: dte, eDce, or dce.
For KML.5-KML.8, valid values: int or lbt.
notApplicable - for KML.10 and KML.F."
::= { prtMlEntry 4}
prtMlBufferSize OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
bits8 (2),
bits256 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The buffer size in bits for absorbing timing jitters."
::= { prtMlEntry 5}
prtMlDsrCts OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
internal (2),
external (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines the DSR and CTS signal handling.
notApplicable - for KML.4-KML.6."
::= { prtMlEntry 6}
prtMlSpeed OBJECT-TYPE
SYNTAX INTEGER
{
bps9600(2),
bps14400(3),
bps19200(4),
bps28800(5),
bps32000(6),
bps48000(7),
bps56000(8),
bps64000(9),
bps128000(10),
bps192000(11),
bps256000(12),
bps384000(13),
bps512000(14),
bps768000(15),
bps1024000(16),
bps1536000(17)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines the Main Link port speed.
KML.1, KML.3, KML.4 support (Kbps): 9.6, 14.4, 19.2, 28.8, 32, 48, 56,
64, 128, 192, 256, 384, 512, 768, 1024, 1536.
KML.2 supports (Kbps): 9.6, 14.4, 19.2, 28.8, 32, 48, 56, 64, 128
KML.5 supports (Kbps): 64, 128.
KML.6 supports (Kbps): 9.6, 19.2, 56.
KML.7-KML.8 support (Kbps): 56, 64, 128, 192, 256, 384, 512,
768, 1024, 1536.
KML.10 supports (Kbps): 64, 128.
KML.F supports (Kbps): 128, 256, 384, 512, 768, 1024, 1536."
::= { prtMlEntry 7}
prtMlStartTS OBJECT-TYPE
SYNTAX Integer32 (0..31)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"0=notApplicable - for all cards except KML.7, KML.8
For KML.7 - valid values: 1..24
For KML.8 - valid values: 1..31."
::= { prtMlEntry 8}
prtMlBypassTs16 OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"notApplicable - for all cards except KML.8."
::= { prtMlEntry 9}
prtMlCallMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
initiate (2),
listen (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object will be used when using an external modem linked to the
KML.1-KML.4 or KML.10 cards.
Initiate - KML card can initiate calls to the modem
Listen - KML card listens only ; cannot initiate a call."
::= { prtMlEntry 10}
prtMlBondingEnable OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Disable/Enable applying the Bonding process, for KML.10 cards.
notApplicable - for all cards except KML.10."
::= { prtMlEntry 11}
prtMlIsdnTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtMlIsdnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Parameters for ISDN main links: KML.10."
::= { prtMainLink 3 }
prtMlIsdnEntry OBJECT-TYPE
SYNTAX PrtMlIsdnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtMlIsdnCnfgIdx, prtMlIsdnIdx }
::= { prtMlIsdnTable 1}
PrtMlIsdnEntry ::=
SEQUENCE {
prtMlIsdnCnfgIdx Integer32,
prtMlIsdnIdx Integer32,
prtMlIsdnSlt INTEGER,
prtMlIsdnMode INTEGER,
prtMlIsdnStandard INTEGER,
prtMlIsdnLocSubNum DisplayString,
prtMlIsdnLocNum DisplayString,
prtMlIsdnOutSubNum DisplayString,
prtMlIsdnBackupCallNum DisplayString,
prtMlIsdnInNumMode INTEGER
}
prtMlIsdnCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
Write operation for the table entries is allowed only to
Config=255. "
::= { prtMlIsdnEntry 1}
prtMlIsdnIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The prtGenPrtIdx index of this link.
Slot*100+1 ."
::= { prtMlIsdnEntry 2}
prtMlIsdnSlt OBJECT-TYPE
SYNTAX INTEGER
{
kmxMlA (103),
kmxMlB (104)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify the slot where
the ML card is inserted in."
::= { prtMlIsdnEntry 3}
prtMlIsdnMode OBJECT-TYPE
SYNTAX INTEGER {
leased (2),
switched(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ISDN Mode.
switched - when ML Mode is Switched Backup.
leased - in all other cases."
::= { prtMlIsdnEntry 4}
prtMlIsdnStandard OBJECT-TYPE
SYNTAX INTEGER { european (2),
israeli (3),
ess5Multipoint(4),
ess5Ptp (5),
dms100 (6),
ntt (7),
nationalIsdn1 (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ISDN standard."
::= { prtMlIsdnEntry 5}
prtMlIsdnLocSubNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..25))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Local sub-number. 4 chars (digits 0..9)."
::= { prtMlIsdnEntry 6}
prtMlIsdnLocNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..25))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Local number. 20 chars (digits: 0..9)."
::= { prtMlIsdnEntry 7}
prtMlIsdnOutSubNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..25))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Out sub-number. 4 chars (digits 0..9)."
::= { prtMlIsdnEntry 8}
prtMlIsdnBackupCallNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..25))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Backup call number. 20 chars (digits: 0..9)."
::= { prtMlIsdnEntry 9}
prtMlIsdnInNumMode OBJECT-TYPE
SYNTAX INTEGER { none (2),
all (3),
local(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In number mode."
::= { prtMlIsdnEntry 10}
prtHsLs OBJECT IDENTIFIER ::= {prtKmux 2}
prtHsLsTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtHsLsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Parameters for the High and Low speed channels.
Cards: KLS.1,KLS.2, KHS.1, KHS.2, KDI/CH, KHSU.1, KHSU.2, KHS.703."
::= { prtHsLs 1 }
prtHsLsEntry OBJECT-TYPE
SYNTAX PrtHsLsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtHsLsCnfgIdx, prtHsLsIdx }
::= { prtHsLsTable 1}
PrtHsLsEntry ::=
SEQUENCE {
prtHsLsCnfgIdx Integer32,
prtHsLsIdx Integer32,
prtHsLsSlt INTEGER,
prtHsLsCommProtocol INTEGER,
prtHsLsAsyncDataLen INTEGER,
prtHsLsTiming INTEGER,
prtHsLsCtrlSignal INTEGER,
prtHsLsCts INTEGER,
prtHsLsRtsCtsDelay INTEGER,
prtHsLsDsrMode INTEGER,
prtHsLsSpeed INTEGER,
prtHsLsUType INTEGER
}
prtHsLsCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
Write operation for the table entries is allowed only to
Config=255. "
::= { prtHsLsEntry 1}
prtHsLsIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The prtGenPrtIdx index of this channel.
In KHSU.1 and KHSU.2 there are three ISDN sub-channels on
each port (2B+D).The sub-channels are numbered:
Slot*100+11 ; Slot*100+12 ; Slot*100+13 (First Port),
Slot*100+14 ; Slot*100+15 ; Slot*100+16 (Second Port)."
::= { prtHsLsEntry 2}
prtHsLsSlt OBJECT-TYPE
SYNTAX INTEGER
{
kmxOpt (106), -- For KDI/CH card type
kmxIO1 (107),
kmxIO2 (108),
kmxIO3 (109),
kmxIO4 (110),
kmxIO5 (111),
kmxIO6 (112),
kmxIO7 (113),
kmxIO8 (114),
kmxIO9 (115),
kmxIO10(116),
kmxIO11(117),
kmxIO12(118)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify the slot where
the card is inserted in.
In the 2104 Unit the entries kmxIO5(111)..kmxIO12(118) are not valid.
The entry kmxOpt(106) is valid only for KDI/CH card."
::= { prtHsLsEntry 3}
prtHsLsCommProtocol OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1),
async (2),
sync (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The communication protocol."
::= { prtHsLsEntry 4}
prtHsLsAsyncDataLen OBJECT-TYPE
SYNTAX INTEGER
{ notApplicable(1),
bit6 (2),
bit7 (3),
bit8 (4),
bit9 (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Async Data Length in Bits.
notApplicable - when prtHsLsCommProtocol=sync or
notApplicable."
::= { prtHsLsEntry 5}
prtHsLsTiming OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
dce (2),
dte1 (3),
dte2 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The variable is RW only if the communications protocol is
sync.
When the comm protocol is async, the variable is RO and its
value is DCE."
::= { prtHsLsEntry 6}
prtHsLsCtrlSignal OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1),
local (2),
dtrAndRts (3),
rts (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control signals."
::= { prtHsLsEntry 7}
prtHsLsCts OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1),
equalRts (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CTS Signal."
::= { prtHsLsEntry 8}
prtHsLsRtsCtsDelay OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
min (2),
ms10 (3),
ms50 (4),
ms100(5),
ms200(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RTS-CTS delay in ms.
notApplicable - when prtHsLsCts=on."
::= { prtHsLsEntry 9}
prtHsLsDsrMode OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1),
permanentOn (2),
sync (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DSR Mode."
::= { prtHsLsEntry 10}
prtHsLsSpeed OBJECT-TYPE
SYNTAX INTEGER {
notConnected(1),
bps300 (2),
bps600 (3),
bps1200 (4),
bps2400 (5),
bps4800 (6),
bps7200 (7),
bps8000 (8),
bps9600 (9),
bps12000(10),
bps14400(11),
bps16000(12),
bps16800(13),
bps19200(14),
bps21600(15),
bps24000(16),
bps26400(17),
bps28800(18),
bps31200(19),
bps32000(20),
bps33600(21),
bps36000(22),
bps38400(23),
bps40800(24),
bps43200(25),
bps45600(26),
bps48000(27),
bps50400(28),
bps52800(29),
bps55200(30),
bps56000(31),
bps57600(32),
bps60000(33),
bps62400(34),
bps64000(35),
bps64800(36),
bps67200(37),
bps69600(38),
bps72000(39),
bps74400(40),
bps76800(41),
bps79200(42),
bps81600(43),
bps84000(44),
bps86400(45),
bps88800(46),
bps91200(47),
bps93600(48),
bps96000(49),
bps98400(50),
bps100800(51),
bps103200(52),
bps105600(53),
bps108000(54),
bps110400(55),
bps112800(56),
bps115200(57),
bps117600(58),
bps120000(59),
bps122400(60),
bps124800(61),
bps127200(62),
bps128000(63),
bps129600(64),
bps134400(65),
bps139200(66),
bps144000(67),
bps148800(68),
bps153600(69),
bps158400(70),
bps163200(71),
bps168000(72),
bps172800(73),
bps177600(74),
bps182400(75),
bps187200(76),
bps192000(77),
bps196800(78),
bps201600(79),
bps206400(80),
bps211200(81),
bps216000(82),
bps220800(83),
bps225600(84),
bps230400(85),
bps235200(86),
bps240000(87),
bps244800(88),
bps249600(89),
bps254400(90),
bps256000(91),
bps259200(92),
bps264000(93),
bps268800(94),
bps273600(95),
bps278400(96),
bps283200(97),
bps288000(98),
bps292800(99),
bps297600(100),
bps302400(101),
bps307200(102),
bps316800(103),
bps326400(104),
bps336000(105),
bps345600(106),
bps355200(107),
bps364800(108),
bps374400(109),
bps384000(110),
bps393600(111),
bps403200(112),
bps412800(113),
bps422400(114),
bps432000(115),
bps441600(116),
bps451200(117),
bps460800(118),
bps470400(119),
bps480000(120),
bps489600(121),
bps499200(122),
bps508800(123),
bps518400(124),
bps528000(125),
bps537600(126),
bps547200(127),
bps556800(128),
bps566400(129),
bps576000(130),
bps585600(131),
bps595200(132),
bps604800(133),
bps614400(134)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"KLS.1 supports (Kbps): 0.3, 0.6, 1.2, 2.4, 4.8, 9.6, 19.2, 38.4.
KLS.1/New, KDI/CH support (Kbps):
Group 1: 0.3, 0.6, 1.2, 2.4, 4.8, 9.6,
19.2, 38.4
Group 2: 7.2, 14.4, 28.8, 57.6
Group 3: 8, 16, 24, 32, 48, 56, 64
KLS.2 supports (Kbps): 2.4, 4.8, 9.6, 19.2.
KHS.1 supports (Kbps): 32, 48, 56, 64, 128, 192, 256, 384
KHS.2 supports (Kbps): ...
KHSU.1/2 support (Kbps): 16, 32, 64.
KHS.703 support (Kbps): 64."
::= { prtHsLsEntry 11}
prtHsLsUType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
regular(2),
type1 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"U Interface Type. Applicable for KHSU.1/2 cards.
The value will be the same for B1 and B2 pair; B3 and B4."
::= { prtHsLsEntry 12}
prtTreMbe OBJECT IDENTIFIER ::= {prtKmux 3}
prtTreMbeTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtTreMbeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry. Parameters for the channels of the
TRE and MBE cards: KTRE, KMBE, KMBE/NEW."
::= {prtTreMbe 2}
prtTreMbeEntry OBJECT-TYPE
SYNTAX PrtTreMbeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtTreMbeCnfgIdx, prtTreMbeIdx }
::= { prtTreMbeTable 1}
PrtTreMbeEntry ::=
SEQUENCE {
prtTreMbeCnfgIdx Integer32,
prtTreMbeIdx Integer32,
prtTreMbeSlt INTEGER,
prtTreMbeLan INTEGER,
prtTreMbeLanRate INTEGER,
prtTreMbeLinkSpeed INTEGER
}
prtTreMbeCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg."
::= {prtTreMbeEntry 1}
prtTreMbeIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique port identifier within the card.
Slot*100+11 ."
::= {prtTreMbeEntry 2}
prtTreMbeSlt OBJECT-TYPE
SYNTAX INTEGER
{
kmxIO1 (107),
kmxIO2 (108),
kmxIO3 (109),
kmxIO4 (110),
kmxIO5 (111),
kmxIO6 (112),
kmxIO7 (113),
kmxIO8 (114),
kmxIO9 (115),
kmxIO10(116),
kmxIO11(117),
kmxIO12(118)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify the slot where
the card is inserted in.
In the 2104 Unit the entries kmxIO5(111)..kmxIO12(118) are not valid."
::= {prtTreMbeEntry 3}
prtTreMbeLan OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
main (2),
remote (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the TRE/MBE port is operated
as main or remote bridge.
Default=remote."
::= {prtTreMbeEntry 4}
prtTreMbeLanRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
r4M (2),
r16M (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Rate of the TRE port
in Mbit/sec. Default-r4M."
::= {prtTreMbeEntry 5}
prtTreMbeLinkSpeed OBJECT-TYPE
SYNTAX INTEGER
{
notConnected(1),
bps9600 (2),
bps19200 (3),
bps28800 (4),
bps38400 (5),
bps48000 (6),
bps57600 (7),
bps67200 (8),
bps76800 (9),
bps86400 (10),
bps96000 (11),
bps105600(12),
bps115200(13),
bps124800(14),
bps128000(15),
bps160000(16),
bps192000(17),
bps224000(18),
bps240000(19),
bps272000(20),
bps304000(21),
bps336000(22),
bps368000(23)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Link Speed."
::= {prtTreMbeEntry 6}
prtVoiceFax OBJECT IDENTIFIER ::= {prtKmux 4}
prtVoiceFaxTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtVoiceFaxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry. Parameters for the channels of the
Voice and Fax channels.
Cards: KVC.1/E&M, KVC.1/FXO, KVC.1/FXS,
KVC.1M/E&M, KVC.1M/FXO, KVC.1M/FXS, KVC.1M/FXSW,
KVC.2/E&M, KVC.2/FXO, KVC.2/FXS,
KVC.2/1/E&M,KVC.2/1/FXO,KVC.2/1/FXS,
KVC.3/E&M, KVC.3/FXO, KVC.3/FXS, KVC.3/S0
KVF.1/E&M, KVF.1/FXO, KVF.1/FXS,
KVF.3/E&M, KVF.3/FXO, KVF.3/FXS,
KVF.4/E&M, KVF.4/FXO, KVF.4/FXS, KVF.4/FXSW, KVF.4/S0,
KVF.4/FXO3, KVF.4/FXS3, KVF.4/NS0
KVF.5 family, KVF.6 family, KVF.8 family."
::= { prtVoiceFax 1}
prtVoiceFaxEntry OBJECT-TYPE
SYNTAX PrtVoiceFaxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtVoiceFaxCnfgIdx, prtVoiceFaxIdx }
::= { prtVoiceFaxTable 1}
PrtVoiceFaxEntry ::=
SEQUENCE {
prtVoiceFaxCnfgIdx Integer32,
prtVoiceFaxIdx Integer32,
prtVoiceFaxSlt INTEGER,
prtVoiceFaxTransGain Integer32,
prtVoiceFaxReceiveGain Integer32,
prtVoiceFaxWire INTEGER,
prtVoiceFaxTimeOut INTEGER,
prtVoiceFaxEchoCanceler INTEGER,
prtVoiceFaxSpeed INTEGER,
prtVoiceFaxMeterRate INTEGER,
prtVoiceFaxCodingLaw INTEGER,
prtVoiceFaxOperMode INTEGER,
prtVoiceFaxSigInOutband OCTET STRING,
prtVoiceFaxTsGroup INTEGER,
prtVoiceFaxRxFaxGain Integer32,
prtVoiceFaxSigHold INTEGER,
prtVoiceFaxIfSignaling INTEGER,
prtVoiceFaxEMTypes INTEGER,
prtVoiceFaxRingFrequency INTEGER,
prtVoiceFaxSignalingStatus OCTET STRING
}
prtVoiceFaxCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg."
::= {prtVoiceFaxEntry 1}
prtVoiceFaxIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port, within the card.
Slot*100+Ch
external ports: Ch=1..10
internal ports (sub-channels): Ch=11..20."
::= {prtVoiceFaxEntry 2}
prtVoiceFaxSlt OBJECT-TYPE
SYNTAX INTEGER
{
kmxIO1 (107),
kmxIO2 (108),
kmxIO3 (109),
kmxIO4 (110),
kmxIO5 (111),
kmxIO6 (112),
kmxIO7 (113),
kmxIO8 (114),
kmxIO9 (115),
kmxIO10(116),
kmxIO11(117),
kmxIO12(118)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify the slot where
the card is inserted in.
In the 2104 Unit the entries kmxIO5(111)..kmxIO12(118) are not valid."
::= {prtVoiceFaxEntry 3}
prtVoiceFaxTransGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transmit gain in dBm. A value of 255 is for notApplicable.
The value will be: real value+50dBm (in order to avoid
negative values)."
::= {prtVoiceFaxEntry 4}
prtVoiceFaxReceiveGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Receive gain in dBm. A value of 255 is for notApplicable.
The value will be: real value+50dBm (in order to avoid
negative values)."
::= {prtVoiceFaxEntry 5}
prtVoiceFaxWire OBJECT-TYPE
SYNTAX INTEGER
{notApplicable(1),
w2wire (2),
w4wire (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Applicable only for E&M cards."
::= {prtVoiceFaxEntry 6}
prtVoiceFaxTimeOut OBJECT-TYPE
SYNTAX INTEGER
{notApplicable(1),
manual(2),
sec30 (3),
sec60 (4),
sec90 (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fax timeout in seconds."
::= {prtVoiceFaxEntry 7}
prtVoiceFaxEchoCanceler OBJECT-TYPE
SYNTAX INTEGER
{notApplicable(1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Echo canceler activation."
::= {prtVoiceFaxEntry 8}
prtVoiceFaxSpeed OBJECT-TYPE
SYNTAX INTEGER
{notConnected(1),
bps4800(2),
bps6400(3),
bps7200(4),
bps8000(5),
bps9600(6),
bps12800(7),
bps16000(8),
bps24000(9),
bps32000(10),
bps64000(11),
bps11200(12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The channel speed.
For KVF.6 and KVF.8 cards, each value will represent [4 x value], since each
channel (Internal or External) is comprised of 4 sub-channels having the selected value."
::= {prtVoiceFaxEntry 9}
prtVoiceFaxMeterRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
r16Khz (2),
r12Khz (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry is valid to KVF.4/FXO3 and KVF.4/FXS3.
Meter Rate means rate of Call Meter in Public Phones, in KHz units.
Must be equal for both channels."
::= {prtVoiceFaxEntry 10}
prtVoiceFaxCodingLaw OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
aLaw (2),
uLaw (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Coding Law. This entry is valid for KVF.4/NS0 external channel and
KVF.6 internal channels."
::= {prtVoiceFaxEntry 11}
prtVoiceFaxOperMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
voiceANDfax (2),
voice (3),
voiceAndFaxAndData (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Operation Mode. This parameter is valid for KVF.6 and KVF.8 family."
::= {prtVoiceFaxEntry 12}
prtVoiceFaxSigInOutband OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable for KVF.4/FXO3, KVF.4/FXS3, KVF.8 family cards.
For KVF.4/FXO3, KVF.4/FXS3:
Octet 1 for Receive parameters.
Octet 2 for Transmit parameters.
It represents 4 parameters, in each Octet :
Bit 7 6 5 4 3 2 1 0
|_____| |_____| |_____| |_____|
MSB Spare On/Off Hook Metering Polarity LSB
Each parameter's bits represent:
00 = NC
01 = Inband(A/B)
10 = Outband(A)
11 = Outband(B)
For KVF.8 family:
It represents 4 parameters, by 2 Octets :
General Bit Code- MSB nibble,
On/Off Hook Bit Code- nibble,
Metering Bit Code- nibble,
Polarity Bit Code- LSB nibble.
Each of General, On/Off Hook, Metering, Polarity Bit Code nibble represents:
0 hex = 0000 = 0
1 hex = 0001 = 1
2 hex = 0010 = A bit
3 hex = 0011 = B bit
4 hex = 0100 = C bit
5 hex = 0101 = D bit
6 hex = 0110 = A bit inverse
7 hex = 0111 = B bit inverse
8 hex = 1000 = C bit inverse
9 hex = 1001 = D bit inverse
A-E hex - not used (invalid values)
When the object is not applicable, 0 Octets will be sent."
::= {prtVoiceFaxEntry 13}
prtVoiceFaxTsGroup OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
s1s2s3s4 (2),
s5s6s7s8 (3),
s9s10s11s12 (4),
s13s14s15s16 (5),
s17s18s19s20 (6),
s21s22s23s24 (7),
s25s26s27s28 (8),
s29s30s31 (9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ts Assignment group. Each KVF.6 internal channel should have
a different value.
's21s22s23s24' = TSs: 21, 22, 23, 24
For KVF.6/E1/16, KVF.6/E1/31 values: 2..9 are applicable.
For KVF.6/T1/12, KVF.6/T1/24 values: 2..7 are applicable."
::= {prtVoiceFaxEntry 14}
prtVoiceFaxRxFaxGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"FAX Receive gain in dBm.
The value will be: (real value*10)+500dBm (in order to avoid
negative and fractional values)."
::= {prtVoiceFaxEntry 15}
prtVoiceFaxSigHold OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
sec0(2),
sec10(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Signal Hold in [sec]. Applicable for all KVF.4 cards except S0/NS0.
When a ML fails, instead of interrupting immediately a
conversation and connecting it again when ML operation is resumed,
user can select to Hold the signal a few seconds before interruption (ML
operation may return during this time).
sec0 = No Hold = 0 sec
sec10= 10 sec hold."
::= {prtVoiceFaxEntry 16}
prtVoiceFaxIfSignaling OBJECT-TYPE
SYNTAX INTEGER
{notApplicable (1),
loopStart (2),
groundStart (3),
winkStart (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Applicable only for KVF.8/FXO, KVF.8/FXS cards.
Interface Analog Signaling."
::= {prtVoiceFaxEntry 17}
prtVoiceFaxEMTypes OBJECT-TYPE
SYNTAX INTEGER
{notApplicable (1),
em1 (2),
em2 (3),
em3 (4),
ssdc5 (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Applicable only for KVF.8/E&M card."
::= {prtVoiceFaxEntry 18}
prtVoiceFaxRingFrequency OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
f16dot7Hz (2),
f20Hz (3),
f25Hz (4),
f50Hz (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Applicable only for KVF.8/E&M card.
The Ringing Frequency units will be in Hz."
::= {prtVoiceFaxEntry 19}
prtVoiceFaxSignalingStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For KM-2100 this parameter should be Read Only.
This object is applicable for KVF.6 and KVF.5 family cards.
It shows the status (0 or 1) of each Signaling Bit (A, B, C, D),
for each TS of a TS Group (according to it's position in the group).
Each nibble represent a TS from the 'TS Group' selected
for the channel (two Octets represents 4 TSs of each group):
Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
|________| |________| |________| |________|
MSB TS i+3 TS i+2 TS i+1 TS i LSB
It represents 4 parameters for each TS:
TS-i TS-i+1 ..
0 - A bit 4 - A bit
1 - B bit 5 - B bit
2 - C bit 6 - C bit
3 - D bit 7 - D bit
When the object is not applicable, 0 Octets will be sent."
::= {prtVoiceFaxEntry 20}
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\imx.txt
--
--RAD-IMX-MIB
-- RAD-IMX MIB (Inverse Multiplexer)
--Title: RAD's IMX-64 PRODUCT MIB
--Version: 1.0
--Date: 1.8.96
--By: Yair Arian
--File: imx.mib
--
--Update: 16.09.99 by Smadar (corrected conflicts with existing RAD MIB).
--Last Update : 06.01.00 by Smadar (added comments for Traps)
imx OBJECT IDENTIFIER ::= {radWan 7}
systemImx OBJECT IDENTIFIER ::= {imx 1}
generalImx OBJECT IDENTIFIER ::= {systemImx 1}
sysGenClearAlarm OBJECT-TYPE
SYNTAX INTEGER { on(1),
off(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear the alarm buffer. The agent resets the variable automatically
to off."
::= { generalImx 1}
sysGenAlarmBuffTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysGenAlarmBuffEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The alarm buffer of the imx."
::= { generalImx 2 }
sysGenAlarmBuffEntry OBJECT-TYPE
SYNTAX SysGenAlarmBuffEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table sysGenAlarmBuffTable."
INDEX {sysGenAlarmBuffIndex}
::= { sysGenAlarmBuffTable 1}
SysGenAlarmBuffEntry ::=
SEQUENCE {
sysGenAlarmBuffIndex Integer32,
sysGenAlarmDescr DisplayString
}
sysGenAlarmBuffIndex OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the alarm buffer Table."
::= { sysGenAlarmBuffEntry 1}
sysGenAlarmDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of the alarm. Up to 80 chars."
::= { sysGenAlarmBuffEntry 2}
sysGenClearLog OBJECT-TYPE
SYNTAX INTEGER { on(1),
off(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear the log buffer. The agent resets the variable automatically
to off."
::= { generalImx 3}
sysGenLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysGenLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The call log buffer of the imx."
::= { generalImx 4 }
sysGenLogEntry OBJECT-TYPE
SYNTAX SysGenLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table sysGenLogTable."
INDEX {sysGenLogIndex}
::= { sysGenLogTable 1}
SysGenLogEntry ::=
SEQUENCE {
sysGenLogIndex Integer32,
sysGenLogDescr DisplayString
}
sysGenLogIndex OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the log Table."
::= { sysGenLogEntry 1}
sysGenLogDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of the entry in the log buffer. Up to 80 chars."
::= { sysGenLogEntry 2}
profilesImx OBJECT IDENTIFIER ::= {systemImx 2}
callProfileImx OBJECT IDENTIFIER ::= {profilesImx 1}
sysCallProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysCallProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing call profile parameters. There are 40 call
profiles."
::= { callProfileImx 1 }
sysCallProfileEntry OBJECT-TYPE
SYNTAX SysCallProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table sysCallProfileTable."
INDEX {sysCallProfileIndex}
::= {sysCallProfileTable 1}
SysCallProfileEntry ::=
SEQUENCE {
sysCallProfileIndex Integer32,
sysCallProfileConnectCmd INTEGER,
sysCallProfileDisconnectCmd INTEGER,
sysCallProfileIncrBwCmd Integer32,
sysCallProfileDecrBwCmd Integer32
}
sysCallProfileIndex OBJECT-TYPE
SYNTAX Integer32 (1..40)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A running index for the table."
::= { sysCallProfileEntry 1}
sysCallProfileConnectCmd OBJECT-TYPE
SYNTAX INTEGER { off(1),
on(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"On(2) - Connect the call profile. The agent will automatically
reset the variable to off(1) ."
::= { sysCallProfileEntry 2}
sysCallProfileDisconnectCmd OBJECT-TYPE
SYNTAX INTEGER { off(1),
on(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"On(2) - Disconnect the call profile. The agent will automatically
reset the variable to off(1)."
::= { sysCallProfileEntry 3}
sysCallProfileIncrBwCmd OBJECT-TYPE
SYNTAX Integer32 (0..6)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Increment bandwidth of a call.
The number of channels to increment 1..6. The agent will automatically
reset the variable to 0."
::= { sysCallProfileEntry 4}
sysCallProfileDecrBwCmd OBJECT-TYPE
SYNTAX Integer32 (0..6)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Decrement bandwidth of a call.
The number of channels to decrement 1..6. The agent will automatically
reset the variable to 0."
::= { sysCallProfileEntry 5}
portImx OBJECT IDENTIFIER ::= {imx 2}
userPortImx OBJECT IDENTIFIER ::= {portImx 1}
prtCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing configuration parameters for the user ports."
::= { userPortImx 1 }
prtCnfgEntry OBJECT-TYPE
SYNTAX PrtCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table prtCnfgTable."
INDEX {prtIndex}
::= {prtCnfgTable 1}
PrtCnfgEntry ::=
SEQUENCE {
prtIndex Integer32,
prtCnfgDecrBwChNum Integer32,
prtCnfgIncrBwChNum Integer32,
prtCnfgDisconnect INTEGER,
prtCnfgActivateLoop INTEGER,
prtCnfgClearLoop INTEGER,
prtCnfgLoopStatus Integer32
}
prtIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user port index."
::= { prtCnfgEntry 1}
prtCnfgDecrBwChNum OBJECT-TYPE
SYNTAX Integer32 (0..6)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Decrement the port bandwidth by the specified number of channels.
The agent resets the variable to 0."
::= { prtCnfgEntry 2}
prtCnfgIncrBwChNum OBJECT-TYPE
SYNTAX Integer32 (0..6)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Increment the port bandwidth by the specified number of channels.
The agent resets the variable to 0."
::= { prtCnfgEntry 3}
prtCnfgDisconnect OBJECT-TYPE
SYNTAX INTEGER { on(1),
off(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Disconnect the port (on(1)). The agent resets the variable to off(2)."
::= { prtCnfgEntry 4}
prtCnfgActivateLoop OBJECT-TYPE
SYNTAX INTEGER { none(1),
local(2),
remote(3),
bonding(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Activate the desired loop on the port.
The agent will reset the variable to none(1)."
::= { prtCnfgEntry 5}
prtCnfgClearLoop OBJECT-TYPE
SYNTAX INTEGER { none(1),
local(2),
remote(3),
bonding(4),
all(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear the desired loop from the port. The agent will
reset the variable to none(1)"
::= { prtCnfgEntry 6}
prtCnfgLoopStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The loop status at this port. The variable is a sum of 2**n where
n is as follows:
0 - Local Loop is on.
1 - Remote Loop is on.
2 - BONDING Loop is on.
If the variable is 0, there is no active loop."
::= { prtCnfgEntry 7}
supervisoryPortImx OBJECT IDENTIFIER ::= {portImx 2}
prtSpUsageImx OBJECT-TYPE
SYNTAX INTEGER { nmsSlip(2),
terminal(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The supervisory port terminal usage definition."
::= { supervisoryPortImx 1}
channelImx OBJECT IDENTIFIER ::= {imx 4}
channelCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChannelCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing configuration parameters for the channels."
::= { channelImx 1 }
channelCnfgEntry OBJECT-TYPE
SYNTAX ChannelCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table channelCnfgTable."
INDEX {chIndex}
::= {channelCnfgTable 1}
ChannelCnfgEntry ::=
SEQUENCE {
chIndex Integer32,
chCnfgUnlock INTEGER,
chCnfgPing INTEGER
}
chIndex OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The channel index."
::= { channelCnfgEntry 1}
chCnfgUnlock OBJECT-TYPE
SYNTAX INTEGER { on(1),
off(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Unlock the channel (on). The agent resets the variable to off."
::= { channelCnfgEntry 2}
chCnfgPing OBJECT-TYPE
SYNTAX INTEGER { on(1),
off(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ping the channel (on). The agent resets the variable to off."
::= { channelCnfgEntry 3}
channelStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChannelStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing status and statistics information for the channels."
::= { channelImx 2 }
channelStatEntry OBJECT-TYPE
SYNTAX ChannelStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table channelStatTable."
INDEX {chIndex}
::= {channelStatTable 1}
ChannelStatEntry ::=
SEQUENCE {
chStatOperStatus INTEGER
}
chStatOperStatus OBJECT-TYPE
SYNTAX INTEGER { up(1),
down(2),
engaged(3),
notDedicated(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational state of the channel based on a ping operation."
::= { channelStatEntry 1}
-- Traps
imxAlarmTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"The trap is sent every time a new alarm is logged into the alarm
buffer. The trap may not be sent more than once in a five second
interval."
::= { radSysWanEvents 2 }
imxCallLogTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"The trap is sent every time a new call log entry is logged into the
log buffer. The trap may not be sent more than once in a five second
interval."
::= { radSysWanEvents 3 }
imxPingTrap NOTIFICATION-TYPE
OBJECTS {chStatOperStatus}
STATUS current
DESCRIPTION
"The trap is sent every time a ping operation is performed on a
channel."
::= { radSysWanEvents 4 }
-- Traps 5-7 having the same enterprise, are used by ipmux.txt.
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\ntePrtCo.txt
--
-- *************************
-- file : NtePrtConfg.txt
--
--Version: 1.0
--Date: 12.11.97
--By: Ilana Schvetz
--File: v:\doc\rdv\mib\ver530\atm\NtePrtConfg.txt
--Last Update: 8-Mar-07 by Shay Harari
-- Copyright 1997 RAD Data Communications, Ltd.
-- All Rights Reserved.
atmNte OBJECT IDENTIFIER ::= { radAtm 3 }
atmNtePrt OBJECT IDENTIFIER ::= { atmNte 2 }
atmNtePrtConfig OBJECT IDENTIFIER ::= { atmNtePrt 1 }
atmNteEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for RAD ATM products."
::= { atmNte 0 }
atmNteConfIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteConfIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Physical interface configuration table."
::= { atmNtePrtConfig 1 }
atmNteConfIfEntry OBJECT-TYPE
SYNTAX AtmNteConfIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Physical interface configuration table.
The ifIndex is of the lowest physical layer."
INDEX { ifIndex}
::= { atmNteConfIfTable 1 }
AtmNteConfIfEntry ::=
SEQUENCE {
atmConfIfTransmitClk
INTEGER,
atmConfIfLoopback
INTEGER,
atmConfIfFrameType
INTEGER,
atmConfIfCardType
INTEGER,
atmConfAtmIfVpiVciLimit
INTEGER,
atmConfIfHwFeatures
INTEGER,
atmConfIfOutputRate
Integer32,
atmConfIfInputRate
Integer32,
atmConfAlarmForwarding
INTEGER,
atmConfIfAllocatedBw
Integer32,
atmConfIfLowerVpi
Integer32,
atmConfIfOamMode
INTEGER,
atmConfIfOamFailureInd
INTEGER
}
atmConfIfTransmitClk OBJECT-TYPE
SYNTAX INTEGER { internal(2), external(3), loopback(4), adaptive(5) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The transmit clock of the port."
::= { atmNteConfIfEntry 1 }
atmConfIfLoopback OBJECT-TYPE
SYNTAX INTEGER { internal(2), external(3), disable(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Interface Loopback."
::= { atmNteConfIfEntry 2 }
atmConfIfFrameType OBJECT-TYPE
SYNTAX INTEGER {
other (1),
sonet (2),
sdh (3),
direct (4),
plcpInternal (5),
plcpExternal (6),
e3 (7),
ethCrcTrans (8),
ethCrcNotTrans (9),
directNoScrmbling (10),
plcpInternalNoScrmbling (11),
plcpExternalNoScrmbling (12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The frame type. Valid values for a 155M interface:
sonet(2), sdh(3). Valid values for a T3 interface:
direct(4), plcpInternal(5), plcpExternal(6),
directNoScrmbling(10), plcpInternalNoScrmbling(11),
plcpExternalNoScrmbling(12). Valid values for Ethernet
interface: ethCrcTrans (8), ethCrcNotTrans(9).
(DS1 interfaces frame type is specified in the DSX1 mib)."
::= { atmNteConfIfEntry 3 }
atmConfIfCardType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
sc13m-155(2),
st13s-155(3),
st13l-155(4),
utp-155(5),
cx-bnc-155(6),
e3(7),
t3(8),
e1(9),
e1-ltu(10),
fc13l-155(11),
fc13lh-155(12),
fc15lh-155(13),
fc13l-e3(14),
fc13lh-e3(15),
fc15lh-e3(16),
fc13l-t3(17),
fc13lh-t3(18),
fc15lh-t3(19)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The card type."
::= { atmNteConfIfEntry 4 }
atmConfAtmIfVpiVciLimit OBJECT-TYPE
SYNTAX INTEGER {
bits15(2),
bits17(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The limit on the sum of the VPI+VCI bits for this interface."
::= { atmNteConfIfEntry 5 }
atmConfIfHwFeatures OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"HW features command."
::= { atmNteConfIfEntry 6 }
atmConfIfOutputRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the output rate in cells/sec, which is
supported per port. Successfully setting this parameter
is dependent on all other ports values calculations,
which are described in the NMS SRS."
::= { atmNteConfIfEntry 7 }
atmConfIfInputRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the input rate in cells/sec, which is
supported per port. Successfully setting this parameter
is dependent on all other ports values calculations,
which are described in the NMS SRS."
::= { atmNteConfIfEntry 8 }
atmConfAlarmForwarding OBJECT-TYPE
SYNTAX INTEGER { disable(2), enable(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables Path AIS Alarm forwarding upon a failure detection. The
following might be considered as a failure: LOS, LOF, LOC, SLM,
LOP, Path AIS and Line AIS.
disable(2) - will not forward an alarm upon a failure on this port.
enable(3) - will forward an alarm upon a failure on this port."
::= { atmNteConfIfEntry 9 }
atmConfIfAllocatedBw OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total VC Bandwidth Allocation."
::= { atmNteConfIfEntry 10 }
atmConfIfLowerVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Lower possible VPI."
::= { atmNteConfIfEntry 11 }
atmConfIfOamMode OBJECT-TYPE
SYNTAX INTEGER {
-- intermediate(1),
segmentTermination(2),
endToEndTermination(3)
-- vpEndToEndVcSegment(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OAM support Mode, which determines the
interface's location in a segment wise."
::= { atmNteConfIfEntry 12 }
atmConfIfOamFailureInd OBJECT-TYPE
SYNTAX INTEGER {
disabled (2),
ais (3),
rdi (4),
aisAndRdi (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows user to define the type of indication
(if any) that will be created upon a LB cell failure,
for all VCs on which OAM loopback traffic is activated.
disabled(2) - no indication will be created.
ais(3) - will cause Tx of AIS.
rdi(4) - will cause Tx of RDI.
aisAndRdi(5) - will cause Tx of AIS & RDI.
For LA-110, indication will be sent only
for VCs with atmConfVcLoopbackFailureInd <> disabled"
::= {atmNteConfIfEntry 13}
atmNteAlarmIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteAlarmIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interface Alarm table."
::= { atmNtePrtConfig 2 }
atmNteAlarmIfEntry OBJECT-TYPE
SYNTAX AtmNteAlarmIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the interface Alarm table."
INDEX { ifIndex}
::= { atmNteAlarmIfTable 1 }
AtmNteAlarmIfEntry ::=
SEQUENCE {
atmInterfaceActiveAlarms
Integer32,
atmThresholdSectionBIP
Integer32,
atmThresholdLineBIP
Integer32,
atmThresholdLineFEBE
Integer32,
atmThresholdPathBIP
Integer32,
atmThresholdPathFEBE
Integer32,
atmThresholdErroredCells
Integer32,
atmThresholdLostCells
Integer32,
atmThresholdMisinsertedCells
Integer32,
atmInterfaceAlarmStatus
INTEGER,
atmInterfaceMaskAlarms
Integer32
}
atmInterfaceActiveAlarms OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Bit String of the active alarms on this interface.
An up bit (1) means there is an active alarm of this
type. A down bit (0) means there is no such alarm.
The meaning of the bits is as follows:
1 - LOS
2 - LOF
3 - Line AIS (SONET)/ PLCP LOF (DS3)
4 - LOP
5 - Path AIS
6 - SLM
7 - LCD
8 - Line RDI (SONET)/ PLCP Yellow (DS3)
9 - Path RDI (SONET)/ RDI (DS3)
10 - Section BIP (SONET)/ P1/P2 (DS3) > Threshold
11 - Line BIP (SONET)/ PLCP BIP (DS3) > Threshold
12 - Line FEBE (SONET)/ PLCP FEBE (DS3) > Threshold
13 - Path BIP > Threshold
14 - Path FEBE > Threshold
15 - HW Failure
"
::= { atmNteAlarmIfEntry 1 }
atmThresholdSectionBIP OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Section BIPs are greater than this threshold,
an active alarm is raised. N/A for ds3/e3 interface."
::= { atmNteAlarmIfEntry 2 }
atmThresholdLineBIP OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Line BIPs are greater than this threshold,
an active alarm is raised. N/A for ds3/e3 interface."
::= { atmNteAlarmIfEntry 3 }
atmThresholdLineFEBE OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Line FEBEs are greater than this threshold,
an active alarm is raised. N/A for ds3/e3 interface."
::= { atmNteAlarmIfEntry 4 }
atmThresholdPathBIP OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Path BIPs are greater than this threshold,
an active alarm is raised."
::= { atmNteAlarmIfEntry 5 }
atmThresholdPathFEBE OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Path FEBEs are greater than this threshold,
an active alarm is raised."
::= { atmNteAlarmIfEntry 6 }
atmThresholdErroredCells OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Errored Cells are greater than this threshold,
an active alarm is raised."
::= { atmNteAlarmIfEntry 7 }
atmThresholdLostCells OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Lost Cells are greater than this threshold,
an active alarm is raised."
::= { atmNteAlarmIfEntry 8 }
atmThresholdMisinsertedCells OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Misinserted Cells are greater than this threshold,
an active alarm is raised."
::= { atmNteAlarmIfEntry 9 }
atmInterfaceAlarmStatus OBJECT-TYPE
SYNTAX INTEGER { off(2),
on(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The variable is on(3) when there is any active alarm
on this interface."
::= { atmNteAlarmIfEntry 10 }
atmInterfaceMaskAlarms OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A Bit String of alarms mask on this interface.
An up bit (1) means that the respective alarm is masked.
A down bit (0) means no mask.
The mask is supported for the following alarms:
1 - LOS
"
::= { atmNteAlarmIfEntry 11 }
atmNteConfVpTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteConfVpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VP configuration table.
The table is an extension to the atmVplTable of
RFC-1695."
::= { atmNtePrtConfig 3 }
atmNteConfVpEntry OBJECT-TYPE
SYNTAX AtmNteConfVpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VP configuration table.
ifIndex of the ATM layer."
INDEX { ifIndex, atmVplVpi }
::= { atmNteConfVpTable 1 }
AtmNteConfVpEntry ::=
SEQUENCE {
atmConfVpPolicing INTEGER,
atmConfVpCCAdminStatus INTEGER,
atmConfVpLoopbackAdminStatus INTEGER,
atmConfVpLoopbackSinkAddress OCTET STRING,
atmConfVpCongestionControl OCTET STRING,
atmConfVpCCDirection INTEGER,
atmConfVpCreationTime DateAndTime,
atmConfVpOamSupport INTEGER,
atmConfVpCCOperStatus INTEGER,
atmConfVpLoopbackTraffic INTEGER,
atmConfVpLoopbackFailureInd INTEGER,
atmConfVpLoopbackFailureThreshold Integer32,
atmConfVpOamDirection INTEGER,
atmConfVpOamDescrIndex Integer32,
atmConfVpConnected INTEGER
}
atmConfVpPolicing OBJECT-TYPE
SYNTAX INTEGER {
none(1),
police(2),
monitor(3),
shaping(4),
policingAndShaping(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Policing method desired for this VPL."
::= { atmNteConfVpEntry 1 }
atmConfVpCCAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up (2),
down (3),
source(4), -- agent send Oam CC cells
sink (5), -- agent check received Oam CC cells
listenToActivationCells (6),
originateActivationCells(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"up(2) - Activate Continuity Check (CC).
down(3) - Deactivate CC.
source(4) - Activate OAM CC(Continuity Check) of local agent
( start sending Oam cells to the remote side ).
sink(5) - Activate CC of remote agent ( start receiving Oam cells from
remote side ).
listenToActivationCells (6) - Passive listener till gets an activation request
originateActivationCells(7) - Sands Activation cell according to atmConfVcCCDirection."
::= {atmNteConfVpEntry 2}
atmConfVpLoopbackAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(2),
down(3),
llid(4),
segment(5),
endToEnd(6),
segmentLlid(7),
endToEndLlid(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"up(2) - Start loopback OAM cells.
down(3) - Stop sending loopback OAM cells.
For ace2002:
up(2) - Transmitting LB cells with llid all ones
(i.e. FFFF..FF)
down(3) - Not transmitting LB cells.
llid(4) - Transmitting LB cells with llid indicated
in the address field.
segment(5) - Transmitting Segment LB cells with llid
all ones.
endToEnd(6) - Transmitting End to End LB cells with llid
all ones.
segmentLlid(7) - Transmitting Segment LB cells with
llid indicated in the address field.
endToEndLlid(8) - Transmitting LB cells with llid
indicated in the address field.
This parameter value might be in conflict with
atmConfVpOamSupport value, since this parameter is for LB,
while atmConfVpOamSupport is for any other OAM cells."
::= {atmNteConfVpEntry 3}
atmConfVpLoopbackSinkAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination address.
For ace101: 2 bytes are used.
For ace2002: 16 bytes are used."
::= {atmNteConfVpEntry 4}
atmConfVpCongestionControl OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Each bit indicates a selection of one option
as the following description. All combinations
are possible and legal.
The codes are:
1 - EPD
2 - CLP
4 - EFCI"
::= {atmNteConfVpEntry 5}
atmConfVpCCDirection OBJECT-TYPE
SYNTAX INTEGER {
both (2),
source(4),
sink (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"both(2) - Agent send OAM CC cells and check received OAM CC cells
source(4)- Agent send OAM CC cells.
sink(5) - Agent checks received OAM CC cells."
::= {atmNteConfVpEntry 6}
atmConfVpCreationTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A date-time in which the VP was created."
::= { atmNteConfVpEntry 7 }
atmConfVpOamSupport OBJECT-TYPE
SYNTAX INTEGER {
intermediate(1),
segmentTermination(2),
endToEndTermination(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OAM support mode, which determines the device location
in a segment wise."
::= { atmNteConfVpEntry 8 }
atmConfVpCCOperStatus OBJECT-TYPE
SYNTAX INTEGER {
initial (1),
source(4),
sink (5),
both (8),
timeout (9),
denied (10),
conflict (11),
manual (12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
initial(1) - The CC activation process is not started.
source(4) - Agent sends OAM CC cells.
sink(5) - Agent checks received OAM CC cells.
both (8) - OAM CC of local and remote agents activation.
timeout (9) - Timeout occured on receiving answer from
the remote agent.
denied (10) - CC activation process rejected by remote agent.
conflict (11) - local and remote sides requested activation
simultaneously.
manual (12) - OAM CC of local agent activated manually.
"
::= {atmNteConfVpEntry 9}
atmConfVpLoopbackTraffic OBJECT-TYPE
SYNTAX INTEGER { off(2), on(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter has both command and status meanings:
off(2) - Set to 'Off' will Stop traffic loop. Getting this
value means that the loop is not running.
on (3) - Set to 'On' will start traffic loop. Getting
this value means that the loop is currently running."
::= {atmNteConfVpEntry 10}
atmConfVpLoopbackFailureInd OBJECT-TYPE
SYNTAX INTEGER {
disabled(2),
segmentAis(3),
segmentRdi(4),
segmentAisAndRdi(5),
endToEndAis(6),
endToEndRdi(7),
endToEndAisAndRdi(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows user to define the Indication that will be created upon
a LB cell failure.
disabled(2) - no indication will be created.
segmentAis(3) - will cause Tx of a segment AIS.
segmentRdi(4) - will cause Tx of a segment RDI.
segmentAisAndRdi(5) - will cause Tx of a segment AIS & RDI.
endToEndAis(6) - will cause Tx of an End to End AIS.
endToEndRdi(7) - will cause Tx of an End to End RDI.
endToEndAisAndRdi(8) - will cause Tx of an End to End AIS & RDI.
Default: disabled(2)."
::= {atmNteConfVpEntry 11}
atmConfVpLoopbackFailureThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of the LB failures before starting transmission of the
Indication defined by atmConfVcLoopbackFailureInd.
Range: 1..16. Default: 1."
::= {atmNteConfVpEntry 12}
atmConfVpOamDirection OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
downStream (2),
upStream (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The direction of OAM cell insertion.
downStream(2) - The OAM cell will be inserted in downStream.
upStream(3) - The OAM cell will be inserted in upStream."
::= {atmNteConfVpEntry 13}
atmConfVpOamDescrIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the VPL's OAM Descriptor index,
according to the OAM Descriptor Configuration Table."
::= {atmNteConfVpEntry 14}
atmConfVpConnected OBJECT-TYPE
SYNTAX INTEGER {
notConnected (1),
mng (2),
bridgePort (3),
ds0Bundle (4),
atm (5),
pw (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether this VP is connected
and if connected, what is it connected to."
::= {atmNteConfVpEntry 15}
--Alarm Table
atmNteAlarmVpTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteAlarmVpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VP Alarm table."
::= { atmNtePrtConfig 5 }
atmNteAlarmVpEntry OBJECT-TYPE
SYNTAX AtmNteAlarmVpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VP Alarm table.
ifIndex of the ATM layer."
INDEX { ifIndex, atmNteVpAlarmVpi}
::= { atmNteAlarmVpTable 1 }
AtmNteAlarmVpEntry ::=
SEQUENCE {
atmNteVpAlarmVpi
Integer32,
atmNteVpActiveAlarms
Integer32
}
atmNteVpAlarmVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI on which there is an active alarm."
::= { atmNteAlarmVpEntry 1 }
atmNteVpActiveAlarms OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Bit String of the active alarms on this VP.
An up bit (1) means there is an active alarm of this
type. A down bit (0) means there is no such alarm.
The meaning of the bits is as follows:
1 - VP AIS
2 - VP Loss Of Continuity
3 - VP RDI Reception
4 - VP Errored Cells > Threshold
5 - VP Lost Cells > Threshold
6 - VP Misinserted Cells > Threshold
9 - VP Loopback Failure
"
::= { atmNteAlarmVpEntry 2 }
atmNteAlarmVcTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteAlarmVcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VC Alarm table."
::= { atmNtePrtConfig 6 }
atmNteAlarmVcEntry OBJECT-TYPE
SYNTAX AtmNteAlarmVcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VC Alarm table.
ifIndex of the ATM layer."
INDEX { ifIndex, atmNteVcAlarmVpi, atmNteVcAlarmVci}
::= { atmNteAlarmVcTable 1 }
AtmNteAlarmVcEntry ::=
SEQUENCE {
atmNteVcAlarmVpi
Integer32,
atmNteVcAlarmVci
Integer32,
atmNteVcActiveAlarms
Integer32
}
atmNteVcAlarmVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the VC on which there is an active alarm."
::= { atmNteAlarmVcEntry 1 }
atmNteVcAlarmVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VCI of the VC on which there is an active alarm."
::= { atmNteAlarmVcEntry 2 }
atmNteVcActiveAlarms OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Bit String of the active alarms on this VC.
An up bit (1) means there is an active alarm of this
type. A down bit (0) means there is no such alarm.
The meaning of the bits is as follows:
1 - VC AIS
2 - VC Loss Of Continuity
3 - VC RDI
4 - VC Errored Cells > Threshold
5 - VC Lost Cells > Threshold
6 - VC Misinserted Cells > Threshold
7 - Tx VC AIS
8 - Tx VC RDI
9 - VC Loopback Failure
"
::= { atmNteAlarmVcEntry 3 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\ace101.txt
--
--
-- file Ace101.txt
--
atmGen OBJECT IDENTIFIER ::= {radAtm 2}
atmPerfHistory OBJECT IDENTIFIER ::= {atmGen 1}
atmIfPerformance OBJECT IDENTIFIER ::= {atmPerfHistory 1}
-- aal5VccXTable ::= { atmIfPerformance 4 } in aal5.txt
atmIfDataTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM interface Data table."
::= { atmIfPerformance 1 }
atmIfDataEntry OBJECT-TYPE
SYNTAX AtmIfDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM interface Data table."
INDEX { ifIndex }
::= { atmIfDataTable 1 }
AtmIfDataEntry ::=
SEQUENCE {
atmIfTimeElapsed
Integer32,
atmIfValidIntervals
Integer32,
atmIfTxCells
Counter32,
atmIfRxCells
Counter32,
atmIfUncorrectedHecs
Counter32
}
atmIfTimeElapsed OBJECT-TYPE
SYNTAX Integer32 (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since
the beginning of the near end current error-
measurement period."
::= { atmIfDataEntry 1 }
atmIfValidIntervals OBJECT-TYPE
SYNTAX Integer32 (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of previous near end intervals for
which valid data was collected. The value will be
96 unless the interface was brought online within
the last 24 hours, in which case the value will be
the number of complete 15 minute near end
intervals since the interface has been online."
::= { atmIfDataEntry 2 }
atmIfTxCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the total number of transmitted
cells, encountered by an ATM interface."
::= { atmIfDataEntry 3 }
atmIfRxCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the total number of received
cells, encountered by an ATM
interface."
::= { atmIfDataEntry 4 }
atmIfUncorrectedHecs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the total number of cells with
uncorrected HEC errors, encountered by an ATM
interface."
::= { atmIfDataEntry 5 }
-- the ATM interface Current
-- The ATM interface current table contains various statistics being
-- collected for the current 15 minute interval.
atmIfCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM interface Current table."
::= { atmIfPerformance 2 }
atmIfCurrentEntry OBJECT-TYPE
SYNTAX AtmIfCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM interface Current table."
INDEX { ifIndex }
::= { atmIfCurrentTable 1 }
AtmIfCurrentEntry ::=
SEQUENCE {
atmIfCurrentTxCells
Gauge32,
atmIfCurrentRxCells
Gauge32,
atmIfCurrentCorrectedHecs
Gauge32,
atmIfCurrentUncorrectedHecs
Gauge32,
atmIfCurrentHecErrorSeconds
Gauge32
}
atmIfCurrentTxCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
cells, encountered by an ATM interface in
the current 15 minute interval."
::= { atmIfCurrentEntry 1 }
atmIfCurrentRxCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
cells, encountered by an ATM
interface in the current 15 minute interval."
::= { atmIfCurrentEntry 2 }
atmIfCurrentCorrectedHecs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of cells with
corrected HEC errors, encountered by an
ATM interface in the current 15 minute
interval."
::= { atmIfCurrentEntry 3 }
atmIfCurrentUncorrectedHecs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of cells with
uncorrected HEC errors, encountered by an ATM
interface in the current 15 minute interval."
::= { atmIfCurrentEntry 4 }
atmIfCurrentHecErrorSeconds OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of seconds with
HEC errors, encountered by an ATM interface in
the current 15 minute interval."
::= { atmIfCurrentEntry 5 }
-- the ATM interface Interval
-- The ATM interface Interval Table contains various statistics
-- collected by each ATM Interface over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
atmIfIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM interface Interval table."
::= { atmIfPerformance 3 }
atmIfIntervalEntry OBJECT-TYPE
SYNTAX AtmIfIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM interface Interval table."
INDEX { ifIndex, atmIfIntervalNumber }
::= { atmIfIntervalTable 1 }
AtmIfIntervalEntry ::=
SEQUENCE {
atmIfIntervalNumber
Integer32,
atmIfIntervalTxCells
Gauge32,
atmIfIntervalRxCells
Gauge32,
atmIfIntervalCorrectedHecs
Gauge32,
atmIfIntervalUncorrectedHecs
Gauge32,
atmIfIntervalHecErrorSeconds
Gauge32
}
atmIfIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { atmIfIntervalEntry 1 }
atmIfIntervalTxCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
cells , encountered by an ATM interface in
one of the previous 96, individual 15 minute,
intervals."
::= { atmIfIntervalEntry 2 }
atmIfIntervalRxCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
cells, encountered by an ATM
interface in one of the previous 96, individual 15
minute, intervals."
::= { atmIfIntervalEntry 3 }
atmIfIntervalCorrectedHecs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of cells with
corrected HEC errors, encountered by an
ATM interface in one of the previous 96,
individual 15 minute, intervals."
::= { atmIfIntervalEntry 4 }
atmIfIntervalUncorrectedHecs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of cells with
uncorrected HEC errors, encountered by an ATM
interface in one of the previous 96, individual 15
minute, intervals."
::= { atmIfIntervalEntry 5 }
atmIfIntervalHecErrorSeconds OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of seconds with
HEC errors, encountered by an ATM interface in one of
the previous 96, individual 15 minute, intervals."
::= { atmIfIntervalEntry 6 }
atmPvcPerformance OBJECT IDENTIFIER ::= {atmPerfHistory 2}
atmVpPerformance OBJECT IDENTIFIER ::= {atmPvcPerformance 1}
-- the ATM VP Current
-- The ATM VP current table contains various statistics being
-- collected for the current 15 minute interval.
atmVpCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVpCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VP Current table."
::= { atmVpPerformance 1 }
atmVpCurrentEntry OBJECT-TYPE
SYNTAX AtmVpCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VP Current table."
INDEX { ifIndex, atmVpCurrentVpi }
::= { atmVpCurrentTable 1 }
AtmVpCurrentEntry ::=
SEQUENCE {
atmVpCurrentVpi
Integer32,
atmVpCurrentRxCellsClp01
Gauge32,
atmVpCurrentRxCellsClp0
Gauge32,
atmVpCurrentGcra0Violations
Gauge32,
atmVpCurrentGcra1Violations
Gauge32,
atmVpCurrentRxAIS
Gauge32,
atmVpCurrentTxAIS
Gauge32,
atmVpCurrentRxRDI
Gauge32,
atmVpCurrentTxRDI
Gauge32,
atmVpCurrentContinuityLoss
Gauge32,
atmVpCurrentUAS
Gauge32,
atmVpCurrentSES
Gauge32,
atmVpCurrentCDC
Gauge32,
atmVpCurrentTotalDiscards
Gauge32,
atmVpCurrentClp0Discards
Gauge32,
atmVpCurrentTotalCellOuts
Gauge32,
atmVpCurrentClp0CellOuts
Gauge32,
atmVpCurrentTaggedOuts
Gauge32,
atmVpCurrentPCR
Gauge32,
atmVpCurrentSCR
Gauge32,
atmVpCurrentMCR
Gauge32,
atmVpCurrentShaperTotalDiscards
Gauge32,
atmVpCurrentShaperClp0Discards
Gauge32,
atmVpCurrentShaperClp1Discards
Gauge32
}
atmVpCurrentVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the VPL."
::= { atmVpCurrentEntry 1 }
atmVpCurrentRxCellsClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
cells, encountered by the VPL of this ATM interface in
the current 15 minute interval."
::= { atmVpCurrentEntry 2 }
atmVpCurrentRxCellsClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpCurrentEntry 3 }
atmVpCurrentGcra0Violations OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of cells
violating GCRA0, encountered by the VPL of this
ATM interface in the current 15 minute
interval."
::= { atmVpCurrentEntry 4 }
atmVpCurrentGcra1Violations OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of cells
violating GCRA1, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpCurrentEntry 5 }
atmVpCurrentRxAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
AIS cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpCurrentEntry 6 }
atmVpCurrentTxAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
AIS cells, encountered by the VPL of this ATM
interface in the current 15 minute interval. Not Supported
in the first phase."
::= { atmVpCurrentEntry 7 }
atmVpCurrentRxRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
RDI cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpCurrentEntry 8 }
atmVpCurrentTxRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
RDI cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpCurrentEntry 9 }
atmVpCurrentContinuityLoss OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of loss of
continuity cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpCurrentEntry 10 }
atmVpCurrentUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Unavailable
Seconds, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpCurrentEntry 11 }
atmVpCurrentSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Severerly Errored
Seconds, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpCurrentEntry 12 }
atmVpCurrentCDC OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Amount of cells dropped in the current 15 minute interval
of the VP connection."
::= { atmVpCurrentEntry 13 }
atmVpCurrentTotalDiscards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells discarded by
the traffic policing entity. This includes cells
originally received with CLP=0 and CLP=1."
::= { atmVpCurrentEntry 14 }
atmVpCurrentClp0Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells received with
CLP=0 and discarded by the traffic policing
entity."
::= { atmVpCurrentEntry 15 }
atmVpCurrentTotalCellOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted
by this VPL. This includes both CLP=0 and CLP=1
cells."
::= { atmVpCurrentEntry 16 }
atmVpCurrentClp0CellOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted
with CLP=0 by this VPL."
::= { atmVpCurrentEntry 17 }
atmVpCurrentTaggedOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells tagged by the
traffic policing entity from CLP=0 to CLP=1 and
transmitted by this VPL."
::= { atmVpCurrentEntry 18 }
atmVpCurrentPCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum traffic rate encountered in the
last interval of the VP connection (monitored once a second)."
::= { atmVpCurrentEntry 19 }
atmVpCurrentSCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average traffic rate during the last interval of the VP
connection."
::= { atmVpCurrentEntry 20 }
atmVpCurrentMCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MCR - The minimum traffic rate encountered in the last
interval of the VP connection (monitored once a second)."
::= { atmVpCurrentEntry 21 }
atmVpCurrentShaperTotalDiscards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells (CLP0 and CLP1) discarded
due to congestion by the traffic shaper."
::= { atmVpCurrentEntry 22 }
atmVpCurrentShaperClp0Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of CLP0 cells discarded
due to congestion by the traffic shaper."
::= { atmVpCurrentEntry 23 }
atmVpCurrentShaperClp1Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of CLP1 cells discarded
due to congestion by the traffic shaper."
::= { atmVpCurrentEntry 24 }
-- The ATM VP current table for Performance Management
-- which contains various statistics being
-- collected for the current 15 minute interval.
atmVpPMCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVpPMCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VP Current table for Performance Management."
::= { atmVpPerformance 2 }
atmVpPMCurrentEntry OBJECT-TYPE
SYNTAX AtmVpPMCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VP Current table for Performance
Management."
INDEX { ifIndex, atmVpPMCurrentVpi, atmVpPMCurrentDir }
::= { atmVpPMCurrentTable 1 }
AtmVpPMCurrentEntry ::=
SEQUENCE {
atmVpPMCurrentDir
INTEGER,
atmVpPMCurrentVpi
Integer32,
atmVpPMCurrentTxClp01
Gauge32,
atmVpPMCurrentTxClp0
Gauge32,
atmVpPMCurrentRxClp01
Gauge32,
atmVpPMCurrentRxClp0
Gauge32,
atmVpPMCurrentErroredCells
Gauge32,
atmVpPMCurrentLostCells
Gauge32,
atmVpPMCurrentMisinsertedCells
Gauge32,
atmVpPMCurrentECB
Gauge32,
atmVpPMCurrentSECB
Gauge32,
atmVpPMCurrentES
Gauge32,
atmVpPMCurrentSES
Gauge32,
atmVpPMCurrentUAS
Gauge32,
atmVpPMCurrentIntervalQuality
INTEGER,
atmVpPMCurrentLastDayQuality
INTEGER
}
atmVpPMCurrentVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the VPL."
::= { atmVpPMCurrentEntry 1 }
atmVpPMCurrentDir OBJECT-TYPE
SYNTAX INTEGER {forward(2), backward(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction of performance management."
::= { atmVpPMCurrentEntry 2 }
atmVpPMCurrentTxClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
CLP 0+1 cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 3 }
atmVpPMCurrentTxClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
CLP 0 cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 4 }
atmVpPMCurrentRxClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
CLP 0+1 cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 5 }
atmVpPMCurrentRxClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
CLP 0 cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 6 }
atmVpPMCurrentErroredCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of errored
cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 7 }
atmVpPMCurrentLostCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of lost
cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 8 }
atmVpPMCurrentMisinsertedCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of misinserted
cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 9 }
atmVpPMCurrentECB OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of ECB,
encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 10 }
atmVpPMCurrentSECB OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SECB,
encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 11 }
atmVpPMCurrentES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Errored Seconds, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 12 }
atmVpPMCurrentSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Severely
Errored Seconds, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 13 }
atmVpPMCurrentUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Unavailable
Seconds, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 14 }
atmVpPMCurrentIntervalQuality OBJECT-TYPE
SYNTAX INTEGER { normal(2), unacceptable(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" If the number of errors per interval is superior to
the atmNteUPLTCR value, the quality of service of
the interval is declared as unacceptable."
DEFVAL { normal }
::= { atmVpPMCurrentEntry 15 }
atmVpPMCurrentLastDayQuality OBJECT-TYPE
SYNTAX INTEGER { normal(2), degraded(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" If the number of errors per 24 hours is superior to
the atmNteDPLTCR value, the quality of service of
the day is declared as degraded."
DEFVAL { normal }
::= { atmVpPMCurrentEntry 16 }
-- the ATM VP Interval
-- The ATM VP Interval Table contains various statistics
-- collected by each ATM Interface/VP over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
atmVpIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVpIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM Vp Interval table."
::= { atmVpPerformance 3 }
atmVpIntervalEntry OBJECT-TYPE
SYNTAX AtmVpIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM Vp Interval table."
INDEX { ifIndex, atmVpIntervalVpi,
atmVpIntervalNumber }
::= { atmVpIntervalTable 1 }
AtmVpIntervalEntry ::=
SEQUENCE {
atmVpIntervalVpi
Integer32,
atmVpIntervalNumber
Integer32,
atmVpIntervalRxCellsClp01
Gauge32,
atmVpIntervalRxCellsClp0
Gauge32,
atmVpIntervalGcra0Violations
Gauge32,
atmVpIntervalGcra1Violations
Gauge32,
atmVpIntervalRxAIS
Gauge32,
atmVpIntervalTxAIS
Gauge32,
atmVpIntervalRxRDI
Gauge32,
atmVpIntervalTxRDI
Gauge32,
atmVpIntervalContinuityLoss
Gauge32,
atmVpIntervalUAS
Gauge32,
atmVpIntervalSES
Gauge32,
atmVpIntervalCDC
Gauge32,
atmVpIntervalTotalDiscards
Gauge32,
atmVpIntervalClp0Discards
Gauge32,
atmVpIntervalTotalCellOuts
Gauge32,
atmVpIntervalClp0CellOuts
Gauge32,
atmVpIntervalTaggedOuts
Gauge32,
atmVpIntervalPCR
Gauge32,
atmVpIntervalSCR
Gauge32,
atmVpIntervalMCR
Gauge32,
atmVpIntervalShaperTotalDiscards
Gauge32,
atmVpIntervalShaperClp0Discards
Gauge32,
atmVpIntervalShaperClp1Discards
Gauge32
}
atmVpIntervalVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the VPL."
::= { atmVpIntervalEntry 1 }
atmVpIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { atmVpIntervalEntry 2 }
atmVpIntervalRxCellsClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
cells , encountered by an ATM interface/VP in
one of the previous 96, individual 15 minute,
intervals."
::= { atmVpIntervalEntry 3 }
atmVpIntervalRxCellsClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpIntervalEntry 4 }
atmVpIntervalGcra0Violations OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
cells violating GCRA0, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpIntervalEntry 5 }
atmVpIntervalGcra1Violations OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
cells violating GCRA1, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpIntervalEntry 6 }
atmVpIntervalRxAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
AIS cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpIntervalEntry 7 }
atmVpIntervalTxAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
AIS cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals. Not supported in the first phase."
::= { atmVpIntervalEntry 8 }
atmVpIntervalRxRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
RDI cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpIntervalEntry 9 }
atmVpIntervalTxRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
RDI cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpIntervalEntry 10 }
atmVpIntervalContinuityLoss OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Continuity
Loss cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpIntervalEntry 11 }
atmVpIntervalUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Unavailable
Seconds, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpIntervalEntry 12 }
atmVpIntervalSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Severerly Errored
Seconds, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpIntervalEntry 13 }
atmVpIntervalCDC OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Amount of cells dropped in the 15 minute interval
of the VP connection."
::= { atmVpIntervalEntry 14 }
atmVpIntervalTotalDiscards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells discarded by
the traffic policing entity. This includes cells
originally received with CLP=0 and CLP=1."
::= { atmVpIntervalEntry 15 }
atmVpIntervalClp0Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells received with
CLP=0 an discarded by the traffic policing
entity."
::= { atmVpIntervalEntry 16 }
atmVpIntervalTotalCellOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted
by this VPL. This includes both CLP=0 and CLP=1
cells."
::= { atmVpIntervalEntry 17 }
atmVpIntervalClp0CellOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted
with CLP=0 by this VPL."
::= { atmVpIntervalEntry 18 }
atmVpIntervalTaggedOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells tagged by the
traffic policing entity from CLP=0 to CLP=1 and
transmitted by this VPL."
::= { atmVpIntervalEntry 19 }
atmVpIntervalPCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum traffic rate encountered in the last
interval of the VP connection (monitored once a second)
encountered by an ATM interface/VP in one of the previous
96, individual 15 minute, intervals."
::= { atmVpIntervalEntry 20 }
atmVpIntervalSCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average traffic rate during the last interval of the
VP connection , encountered by an ATM interface/VP in one
of the previous 96, individual 15 minute, intervals."
::= { atmVpIntervalEntry 21 }
atmVpIntervalMCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MCR - The minimum traffic rate encountered in the last
interval of the VP connection (monitored once a second)
encountered by an ATM interface/VP in one of the previous
96, individual 15 minute, intervals."
::= { atmVpIntervalEntry 22 }
atmVpIntervalShaperTotalDiscards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells (CLP0 and CLP1) discarded
due to congestion by the traffic shaper."
::= { atmVpIntervalEntry 23 }
atmVpIntervalShaperClp0Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of CLP0 cells discarded
due to congestion by the traffic shaper."
::= { atmVpIntervalEntry 24 }
atmVpIntervalShaperClp1Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of CLP1 cells discarded
due to congestion by the traffic shaper."
::= { atmVpIntervalEntry 25 }
-- The ATM VP Interval Table for Performance Management
-- contains various statistics
-- collected by each ATM Interface/VP over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
atmVpPMIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVpPMIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM Vp Interval table for Performance Management."
::= { atmVpPerformance 4 }
atmVpPMIntervalEntry OBJECT-TYPE
SYNTAX AtmVpPMIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM Vp Interval table for Performance
Management."
INDEX { ifIndex, atmVpPMIntervalVpi, atmVpPMIntervalDir, atmVpPMIntervalNumber }
::= { atmVpPMIntervalTable 1 }
AtmVpPMIntervalEntry ::=
SEQUENCE {
atmVpPMIntervalVpi
Integer32,
atmVpPMIntervalDir
INTEGER,
atmVpPMIntervalNumber
Integer32,
atmVpPMIntervalTxClp01
Gauge32,
atmVpPMIntervalTxClp0
Gauge32,
atmVpPMIntervalRxClp01
Gauge32,
atmVpPMIntervalRxClp0
Gauge32,
atmVpPMIntervalErroredCells
Gauge32,
atmVpPMIntervalLostCells
Gauge32,
atmVpPMIntervalMisinsertedCells
Gauge32,
atmVpPMIntervalECB
Gauge32,
atmVpPMIntervalSECB
Gauge32,
atmVpPMIntervalES
Gauge32,
atmVpPMIntervalSES
Gauge32,
atmVpPMIntervalUAS
Gauge32,
atmVpPMIntervalQuality
INTEGER,
atmVpPMIntervalLastDayQuality
INTEGER
}
atmVpPMIntervalVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the VPL."
::= { atmVpPMIntervalEntry 1 }
atmVpPMIntervalDir OBJECT-TYPE
SYNTAX INTEGER {forward(2),
backward(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction of performance management."
::= { atmVpPMIntervalEntry 2 }
atmVpPMIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { atmVpPMIntervalEntry 3 }
atmVpPMIntervalTxClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
CLP 0+1 cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 4 }
atmVpPMIntervalTxClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
CLP 0 cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 5 }
atmVpPMIntervalRxClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
CLP 0+1 cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 6 }
atmVpPMIntervalRxClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
CLP 0 cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 7 }
atmVpPMIntervalErroredCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Errored
cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 8 }
atmVpPMIntervalLostCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Lost
cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 9 }
atmVpPMIntervalMisinsertedCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Misinserted
cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 10 }
atmVpPMIntervalECB OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of ECBs
encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 11 }
atmVpPMIntervalSECB OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SECBs
encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 12 }
atmVpPMIntervalES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Errored
Seconds, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 13 }
atmVpPMIntervalSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Severely
Errored Seconds, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 14 }
atmVpPMIntervalUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Unavailable
Seconds, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 15 }
atmVpPMIntervalQuality OBJECT-TYPE
SYNTAX INTEGER { normal(2), unacceptable(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" If the number of errors per interval is superior to
the atmNteUPLTCR value, the quality of service of
the interval is declared as unacceptable."
DEFVAL { normal }
::= { atmVpPMIntervalEntry 16}
atmVpPMIntervalLastDayQuality OBJECT-TYPE
SYNTAX INTEGER { normal(2), degraded(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" If the number of errors per 24 hours is superior to
the atmNteDPLTCR value, the quality of service of
the day is declared as degraded."
DEFVAL { normal }
::= { atmVpPMIntervalEntry 17}
-- VP QoS Table
atmVpQoSTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVpQoSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VP QoS table."
::= { atmVpPerformance 5 }
atmVpQoSEntry OBJECT-TYPE
SYNTAX AtmVpQoSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"."
INDEX { ifIndex, atmVplVpi, atmVpQoSPeriodRef }
::= { atmVpQoSTable 1 }
AtmVpQoSEntry ::=
SEQUENCE {
atmVpQoSPeriodRef INTEGER,
atmVpQoSElapsedTime Integer32,
atmVpQoSUAS Gauge32
}
atmVpQoSPeriodRef OBJECT-TYPE
SYNTAX INTEGER {
currentPeriod (1),
lastPeriod (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is an index that specifies which period of time, the next
2 objects refer to.
currentPeriod - the period since last systemResetAllStatsCmd received or
since Start-up (if no systemResetAllStatsCmd was received since
Start-up) until now.
lastPeriod - the period between last two commands of systemResetAllStatsCmd.
- If only one command occurred since Start-up: the period between
Start-up and last command.
- If no command occurred since Start-up: this period will not
actually exist. In this case, he following 5 objects will be 0."
::= { atmVpQoSEntry 1 }
atmVpQoSElapsedTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed Time in seconds.
- for atmVpQoSPeriodRef = currentPeriod:
The period since last systemResetAllStatsCmd received or since Start-up
(if no systemResetAllStatsCmd was received since Start-up) until now.
- for atmVpQoSPeriodRef = lastPeriod:
The value of atmVpQoSElapsedTime when last systemResetAllStatsCmd
was received."
::= { atmVpQoSEntry 2 }
atmVpQoSUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Unavailable Seconds for the reference period (atmVpQoSPeriodRef)."
::= { atmVpQoSEntry 3 }
-- VP PM QoS Table
atmVpPMQoSTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVpPMQoSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The PM VP QoS table."
::= { atmVpPerformance 6 }
atmVpPMQoSEntry OBJECT-TYPE
SYNTAX AtmVpPMQoSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"."
INDEX { ifIndex, atmVplVpi, atmVpPMQoSDirection ,atmVpPMQoSPeriodRef }
::= { atmVpPMQoSTable 1 }
AtmVpPMQoSEntry ::=
SEQUENCE {
atmVpPMQoSDirection INTEGER,
atmVpPMQoSPeriodRef INTEGER,
atmVpPMQoSCLR Gauge32,
atmVpPMQoSCER Gauge32,
atmVpPMQoSCMR Gauge32
}
atmVpPMQoSDirection OBJECT-TYPE
SYNTAX INTEGER
{
forward (2),
backward (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction of performance management."
::= { atmVpPMQoSEntry 1 }
atmVpPMQoSPeriodRef OBJECT-TYPE
SYNTAX INTEGER
{
currentPeriod (1),
lastPeriod (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is an index that specifies which period of time, the next
5 objects refer to.
currentPeriod - the period since last systemResetAllStatsCmd received or
since Start-up (if no systemResetAllStatsCmd was received since
Start-up) until now.
lastPeriod - the period between last two commands of systemResetAllStatsCmd.
- If only one command occurred since Start-up: the period between
Start-up and last command.
- If no command occurred since Start-up: this period will not
actually exist. In this case, he following 5 objects will be 0."
::= { atmVpPMQoSEntry 2 }
atmVpPMQoSCLR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Loss Ratio counter for the reference period (atmVpPMQoSPeriodRef)-
defined in accordance with I.356 , in %.
The value will be multipuled by 100."
::= { atmVpPMQoSEntry 3 }
atmVpPMQoSCER OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Error Ratio counter for the reference period (atmVpPMQoSPeriodRef)
defined in accordance with I.356 , in %.
The value will be multipuled by 100."
::= { atmVpPMQoSEntry 4 }
atmVpPMQoSCMR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Misinsertion Ratio counter for the reference period (atmVpPMQoSPeriodRef)
defined in accordance with I.356 , cells/sec ."
::= { atmVpPMQoSEntry 5 }
--VP Shaper Statistics Table
atmVpShaperStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVpShaperStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VP shaper statistics table."
::= { atmVpPerformance 7 }
atmVpShaperStatEntry OBJECT-TYPE
SYNTAX AtmVpShaperStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VP shaper statistics table."
INDEX { ifIndex, atmVplVpi }
::= { atmVpShaperStatTable 1 }
AtmVpShaperStatEntry ::=
SEQUENCE {
atmVpShaperDiscarded Counter32,
atmVpShaperOccupation Integer32,
atmVpShaperMaxOccupation Integer32,
atmVpShaperLevel INTEGER,
atmVpShaperEpdDropped Counter32,
atmVpShaperTotalEpdDropped Counter32
}
atmVpShaperDiscarded OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Cells that were discarded in the shaper on that VPC due
to buffer overflow.
This counter counts till it reaches its MAX value (20 bits) and then
rolls over."
::= { atmVpShaperStatEntry 1 }
atmVpShaperOccupation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Cells that are currently stored in the buffer.
This parameter is limited to 20 bits."
::= { atmVpShaperStatEntry 2}
atmVpShaperMaxOccupation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Maximum number of Cells that were stored in the buffer,
since this VP was activated. This parameter is limited to 20 bits."
::= { atmVpShaperStatEntry 3}
atmVpShaperLevel OBJECT-TYPE
SYNTAX INTEGER {
empty (1),
full (2),
below (3),
above (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The occupation of the buffer according to a predefined threshold.
empty - buffer is Empty
full - buffer is Full
below - buffer is Below the threshold
above - buffer is Above the threshold. This is also the trigger to
start EPD\PPD mechanism, if set for the VPC."
::= { atmVpShaperStatEntry 4}
atmVpShaperEpdDropped OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Cells that were dropped in the shaper on that VPC
due to EPD\PPD mechanism in the last second.
This parameter is limited to 24 bits.
Applicable for a EPD/PPD VP only."
::= { atmVpShaperStatEntry 5}
atmVpShaperTotalEpdDropped OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Total number of Cells that were dropped in the shaper on that
VPC due to EPD\PPD mechanism in the last 15 minutes. This counter
automatically reset itself every 15 minutes.
Applicable for a EPD/PPD VP only."
::= { atmVpShaperStatEntry 6}
atmVcPerformance OBJECT IDENTIFIER ::= {atmPvcPerformance 2}
-- the ATM VC Current
-- The ATM VC current table contains various statistics being
-- collected for the current 15 minute interval.
atmVcCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVcCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VC Current table."
::= { atmVcPerformance 1 }
atmVcCurrentEntry OBJECT-TYPE
SYNTAX AtmVcCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VC Current table."
INDEX { ifIndex, atmVcCurrentVpi, atmVcCurrentVci }
::= { atmVcCurrentTable 1 }
AtmVcCurrentEntry ::=
SEQUENCE {
atmVcCurrentVpi
Integer32,
atmVcCurrentVci
Integer32,
atmVcCurrentRxCellsClp01
Gauge32,
atmVcCurrentRxCellsClp0
Gauge32,
atmVcCurrentGcra0Violations
Gauge32,
atmVcCurrentGcra1Violations
Gauge32,
atmVcCurrentRxAIS
Gauge32,
atmVcCurrentTxAIS
Gauge32,
atmVcCurrentRxRDI
Gauge32,
atmVcCurrentTxRDI
Gauge32,
atmVcCurrentContinuityLoss
Gauge32,
atmVcCurrentUAS
Gauge32,
atmVcCurrentSES
Gauge32,
atmVcCurrentCDC
Gauge32,
atmVcCurrentTotalDiscards
Gauge32,
atmVcCurrentClp0Discards
Gauge32,
atmVcCurrentTotalCellOuts
Gauge32,
atmVcCurrentClp0CellOuts
Gauge32,
atmVcCurrentTaggedOuts
Gauge32,
atmVcCurrentPCR
Gauge32,
atmVcCurrentSCR
Gauge32,
atmVcCurrentMCR
Gauge32,
atmVcCurrentShaperTotalDiscards
Gauge32,
atmVcCurrentShaperClp0Discards
Gauge32,
atmVcCurrentShaperClp1Discards
Gauge32
}
atmVcCurrentVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the VCL."
::= { atmVcCurrentEntry 1 }
atmVcCurrentVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VCI of the VCL."
::= { atmVcCurrentEntry 2 }
atmVcCurrentRxCellsClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
cells, encountered by the VCL of this ATM interface in
the current 15 minute interval."
::= { atmVcCurrentEntry 3 }
atmVcCurrentRxCellsClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcCurrentEntry 4 }
atmVcCurrentGcra0Violations OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of cells
violating GCRA0, encountered by the VCL of this
ATM interface in the current 15 minute
interval."
::= { atmVcCurrentEntry 5 }
atmVcCurrentGcra1Violations OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of cells
violating GCRA1, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcCurrentEntry 6 }
atmVcCurrentRxAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
AIS cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcCurrentEntry 7 }
atmVcCurrentTxAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
AIS cells, encountered by the VCL of this ATM
interface in the current 15 minute interval. Not Supported
in the first phase."
::= { atmVcCurrentEntry 8 }
atmVcCurrentRxRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
RDI cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcCurrentEntry 9 }
atmVcCurrentTxRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
RDI cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcCurrentEntry 10 }
atmVcCurrentContinuityLoss OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of loss of
continuity cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcCurrentEntry 11 }
atmVcCurrentUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Unavailable
Seconds, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcCurrentEntry 12 }
atmVcCurrentSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Severerly Errored
Seconds, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcCurrentEntry 13 }
atmVcCurrentCDC OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Amount of cells dropped in the current 15 minute interval
of the VC connection."
::= { atmVcCurrentEntry 14 }
atmVcCurrentTotalDiscards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells discarded by
the traffic policing entity. This includes cells
originally received with CLP=0 and CLP=1."
::= { atmVcCurrentEntry 15 }
atmVcCurrentClp0Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells received with
CLP=0 an discarded by the traffic policing
entity."
::= { atmVcCurrentEntry 16 }
atmVcCurrentTotalCellOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted
by this VPL. This includes both CLP=0 and CLP=1
cells."
::= { atmVcCurrentEntry 17 }
atmVcCurrentClp0CellOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted
with CLP=0 by this VPL."
::= { atmVcCurrentEntry 18 }
atmVcCurrentTaggedOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells tagged by the
traffic policing entity from CLP=0 to CLP=1 and
transmitted by this VPL."
::= { atmVcCurrentEntry 19 }
atmVcCurrentPCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum traffic rate encountered in the last
interval of the VC connection (monitored once a second)."
::= { atmVcCurrentEntry 20 }
atmVcCurrentSCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average traffic rate during the last interval
of the VC connection."
::= { atmVcCurrentEntry 21 }
atmVcCurrentMCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MCR - The minimum traffic rate encountered in the last
interval of the VC connection (monitored once a second)."
::= { atmVcCurrentEntry 22 }
atmVcCurrentShaperTotalDiscards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells (CLP0 and CLP1) discarded
due to congestion by the traffic shaper."
::= { atmVcCurrentEntry 23 }
atmVcCurrentShaperClp0Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of CLP0 cells discarded
due to congestion by the traffic shaper."
::= { atmVcCurrentEntry 24 }
atmVcCurrentShaperClp1Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of CLP1 cells discarded
due to congestion by the traffic shaper."
::= { atmVcCurrentEntry 25 }
-- The ATM VC current table for Performance Management
-- which contains various statistics being
-- collected for the current 15 minute interval.
atmVcPMCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVcPMCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VC Current table for Performance Management."
::= { atmVcPerformance 2 }
atmVcPMCurrentEntry OBJECT-TYPE
SYNTAX AtmVcPMCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VC Current table for Performance
Management."
INDEX { ifIndex, atmVcPMCurrentVpi,
atmVcPMCurrentVci, atmVcPMCurrentDir }
::= { atmVcPMCurrentTable 1 }
AtmVcPMCurrentEntry ::=
SEQUENCE {
atmVcPMCurrentVpi
Integer32,
atmVcPMCurrentVci
Integer32,
atmVcPMCurrentDir
Integer32,
atmVcPMCurrentTxClp01
Gauge32,
atmVcPMCurrentTxClp0
Gauge32,
atmVcPMCurrentRxClp01
Gauge32,
atmVcPMCurrentRxClp0
Gauge32,
atmVcPMCurrentErroredCells
Gauge32,
atmVcPMCurrentLostCells
Gauge32,
atmVcPMCurrentMisinsertedCells
Gauge32,
atmVcPMCurrentECB
Gauge32,
atmVcPMCurrentSECB
Gauge32,
atmVcPMCurrentES
Gauge32,
atmVcPMCurrentSES
Gauge32,
atmVcPMCurrentUAS
Gauge32,
atmVcPMCurrentIntervalQuality
INTEGER,
atmVcPMCurrentLastDayQuality
INTEGER
}
atmVcPMCurrentVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the VCL."
::= { atmVcPMCurrentEntry 1 }
atmVcPMCurrentVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VCI of the VCL."
::= { atmVcPMCurrentEntry 2 }
atmVcPMCurrentDir OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction of Performance Management."
::= { atmVcPMCurrentEntry 3 }
atmVcPMCurrentTxClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
CLP 0+1 cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 4 }
atmVcPMCurrentTxClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
CLP 0 cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 5 }
atmVcPMCurrentRxClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
CLP 0+1 cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 6 }
atmVcPMCurrentRxClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
CLP 0 cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 7 }
atmVcPMCurrentErroredCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of errored
cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 8 }
atmVcPMCurrentLostCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of lost
cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 9 }
atmVcPMCurrentMisinsertedCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of misinserted
cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 10 }
atmVcPMCurrentECB OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of ECBs
encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 11 }
atmVcPMCurrentSECB OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SECBs
encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 12 }
atmVcPMCurrentES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Errored Seconds, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 13 }
atmVcPMCurrentSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Severely
Errored Seconds, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 14 }
atmVcPMCurrentUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Severely
Errored Seconds, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 15 }
atmVcPMCurrentIntervalQuality OBJECT-TYPE
SYNTAX INTEGER { normal(2), unacceptable(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" If the number of errors per interval is superior to
the atmNteUPLTCR value, the quality of service of
the interval is declared as unacceptable."
DEFVAL { normal }
::= { atmVcPMCurrentEntry 16 }
atmVcPMCurrentLastDayQuality OBJECT-TYPE
SYNTAX INTEGER { normal(2), degraded(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" If the number of errors per 24 hours is superior to
the atmNteDPLTCR value, the quality of service of
the day is declared as degraded."
DEFVAL { normal }
::= { atmVcPMCurrentEntry 17 }
-- the ATM VC Interval
-- The ATM VC Interval Table contains various statistics
-- collected by each ATM Interface/VC over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
atmVcIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVcIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM Vc Interval table."
::= { atmVcPerformance 3 }
atmVcIntervalEntry OBJECT-TYPE
SYNTAX AtmVcIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM Vc Interval table."
INDEX { ifIndex, atmVcIntervalVpi,
atmVcIntervalVci, atmVcIntervalNumber }
::= { atmVcIntervalTable 1 }
AtmVcIntervalEntry ::=
SEQUENCE {
atmVcIntervalVpi
Integer32,
atmVcIntervalVci
Integer32,
atmVcIntervalNumber
Integer32,
atmVcIntervalRxCellsClp01
Gauge32,
atmVcIntervalRxCellsClp0
Gauge32,
atmVcIntervalGcra0Violations
Gauge32,
atmVcIntervalGcra1Violations
Gauge32,
atmVcIntervalRxAIS
Gauge32,
atmVcIntervalTxAIS
Gauge32,
atmVcIntervalRxRDI
Gauge32,
atmVcIntervalTxRDI
Gauge32,
atmVcIntervalContinuityLoss
Gauge32,
atmVcIntervalUAS
Gauge32,
atmVcIntervalSES
Gauge32,
atmVcIntervalCDC
Gauge32,
atmVcIntervalTotalDiscards
Gauge32,
atmVcIntervalClp0Discards
Gauge32,
atmVcIntervalTotalCellOuts
Gauge32,
atmVcIntervalClp0CellOuts
Gauge32,
atmVcIntervalTaggedOuts
Gauge32,
atmVcIntervalPCR
Gauge32,
atmVcIntervalSCR
Gauge32,
atmVcIntervalMCR
Gauge32,
atmVcIntervalShaperTotalDiscards
Gauge32,
atmVcIntervalShaperClp0Discards
Gauge32,
atmVcIntervalShaperClp1Discards
Gauge32
}
atmVcIntervalVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the VCL."
::= { atmVcIntervalEntry 1 }
atmVcIntervalVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VCI of the VCL."
::= { atmVcIntervalEntry 2 }
atmVcIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { atmVcIntervalEntry 3 }
atmVcIntervalRxCellsClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
cells , encountered by an ATM interface/VC in
one of the previous 96, individual 15 minute,
intervals."
::= { atmVcIntervalEntry 4 }
atmVcIntervalRxCellsClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcIntervalEntry 5 }
atmVcIntervalGcra0Violations OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
cells violating GCRA0, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcIntervalEntry 6 }
atmVcIntervalGcra1Violations OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
cells violating GCRA1, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcIntervalEntry 7 }
atmVcIntervalRxAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
AIS cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcIntervalEntry 8 }
atmVcIntervalTxAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
AIS cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals. Not supported in the first phase."
::= { atmVcIntervalEntry 9 }
atmVcIntervalRxRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
RDI cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcIntervalEntry 10 }
atmVcIntervalTxRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
RDI cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcIntervalEntry 11 }
atmVcIntervalContinuityLoss OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Continuity
Loss cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcIntervalEntry 12 }
atmVcIntervalUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Unavailable
Seconds, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcIntervalEntry 13 }
atmVcIntervalSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Severerly Errored
Seconds, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcIntervalEntry 14 }
atmVcIntervalCDC OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Amount of cells dropped in the 15 minute interval
of the VC connection."
::= { atmVcIntervalEntry 15 }
atmVcIntervalTotalDiscards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells discarded by
the traffic policing entity. This includes cells
originally received with CLP=0 and CLP=1."
::= { atmVcIntervalEntry 16 }
atmVcIntervalClp0Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells received with
CLP=0 an discarded by the traffic policing
entity."
::= { atmVcIntervalEntry 17 }
atmVcIntervalTotalCellOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted
by this VPL. This includes both CLP=0 and CLP=1
cells."
::= { atmVcIntervalEntry 18 }
atmVcIntervalClp0CellOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted
with CLP=0 by this VPL."
::= { atmVcIntervalEntry 19 }
atmVcIntervalTaggedOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells tagged by the
traffic policing entity from CLP=0 to CLP=1 and
transmitted by this VPL."
::= { atmVcIntervalEntry 20 }
atmVcIntervalPCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum traffic rate encountered in the
last interval of the VC connection (monitored once a second)
encountered by an ATM interface/VC in one of the previous 96,
individual 15 minute, intervals."
::= { atmVcIntervalEntry 21 }
atmVcIntervalSCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average traffic rate during the last interval
of the VC connection, encountered by an ATM interface/VC
in one of the previous 96, individual 15 minute, intervals."
::= { atmVcIntervalEntry 22 }
atmVcIntervalMCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MCR - The minimum traffic rate encountered in the last
interval of the VC connection (monitored once a second)
encountered by an ATM interface/VC in one of the previous 96,
individual 15 minute, intervals."
::= { atmVcIntervalEntry 23 }
atmVcIntervalShaperTotalDiscards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells (CLP0 and CLP1) discarded
due to congestion by the traffic shaper."
::= { atmVcIntervalEntry 24 }
atmVcIntervalShaperClp0Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of CLP0 cells discarded
due to congestion by the traffic shaper."
::= { atmVcIntervalEntry 25 }
atmVcIntervalShaperClp1Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of CLP1 cells discarded
due to congestion by the traffic shaper."
::= { atmVcIntervalEntry 26 }
-- The ATM VC Interval Table for Performance Management
-- which contains various statistics
-- collected by each ATM Interface/VC over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
atmVcPMIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVcPMIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM Vc Interval table for Performance Management."
::= { atmVcPerformance 4 }
--atmCESAAL1StatsTable OBJECT IDENTIFIER ::= {atmVcPerformance 5} (see hybCES.txt)
atmVcPMIntervalEntry OBJECT-TYPE
SYNTAX AtmVcPMIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM Vc Interval table for Performance
Management."
INDEX { ifIndex, atmVcPMIntervalVpi,
atmVcPMIntervalVci, atmVcPMIntervalDir, atmVcPMIntervalNumber }
::= { atmVcPMIntervalTable 1 }
AtmVcPMIntervalEntry ::=
SEQUENCE {
atmVcPMIntervalVpi
Integer32,
atmVcPMIntervalVci
Integer32,
atmVcPMIntervalDir
INTEGER,
atmVcPMIntervalNumber
Integer32,
atmVcPMIntervalTxClp01
Gauge32,
atmVcPMIntervalTxClp0
Gauge32,
atmVcPMIntervalRxClp01
Gauge32,
atmVcPMIntervalRxClp0
Gauge32,
atmVcPMIntervalErroredCells
Gauge32,
atmVcPMIntervalLostCells
Gauge32,
atmVcPMIntervalMisinsertedCells
Gauge32,
atmVcPMIntervalECB
Gauge32,
atmVcPMIntervalSECB
Gauge32,
atmVcPMIntervalES
Gauge32,
atmVcPMIntervalSES
Gauge32,
atmVcPMIntervalUAS
Gauge32,
atmVcPMIntervalQuality
INTEGER,
atmVcPMIntervalLastDayQuality
INTEGER
}
atmVcPMIntervalVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the VCL."
::= { atmVcPMIntervalEntry 1 }
atmVcPMIntervalVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VCI of the VCL."
::= { atmVcPMIntervalEntry 2 }
atmVcPMIntervalDir OBJECT-TYPE
SYNTAX INTEGER {forward(2),
backward(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction of Performance Management."
::= { atmVcPMIntervalEntry 3 }
atmVcPMIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { atmVcPMIntervalEntry 4 }
atmVcPMIntervalTxClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
CLP 0+1 cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 5 }
atmVcPMIntervalTxClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
CLP 0 cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 6 }
atmVcPMIntervalRxClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
CLP 0+1 cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 7 }
atmVcPMIntervalRxClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
CLP 0 cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 8 }
atmVcPMIntervalErroredCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Errored
cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 9 }
atmVcPMIntervalLostCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Lost
cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 10 }
atmVcPMIntervalMisinsertedCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Misinserted
cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 11 }
atmVcPMIntervalECB OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of ECBs
encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 12 }
atmVcPMIntervalSECB OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SECBs
encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 13 }
atmVcPMIntervalES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Errored
Seconds, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 14 }
atmVcPMIntervalSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Severely
Errored Seconds, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 15 }
atmVcPMIntervalUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Unavailable
Seconds, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 16 }
atmVcPMIntervalQuality OBJECT-TYPE
SYNTAX INTEGER { normal(2), unacceptable(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" If the number of errors per interval is superior to
the atmNteUPLTCR value, the quality of service of
the interval is declared as unacceptable."
DEFVAL { normal }
::= { atmVcPMIntervalEntry 17}
atmVcPMIntervalLastDayQuality OBJECT-TYPE
SYNTAX INTEGER { normal(2), degraded(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" If the number of errors per 24 hours is superior to
the atmNteDPLTCR value, the quality of service of
the day is declared as degraded."
DEFVAL { normal }
::= { atmVcPMIntervalEntry 18}
-- VC QoS Table
atmVcQoSTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVcQoSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VP QoS table."
::= { atmVcPerformance 6 }
atmVcQoSEntry OBJECT-TYPE
SYNTAX AtmVcQoSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VP table."
INDEX { ifIndex, atmVclVpi, atmVclVci, atmVcQoSPeriodRef }
::= { atmVcQoSTable 1 }
AtmVcQoSEntry ::=
SEQUENCE {
atmVcQoSPeriodRef INTEGER,
atmVcQoSElapsedTime Integer32,
atmVcQoSUAS Gauge32
}
atmVcQoSPeriodRef OBJECT-TYPE
SYNTAX INTEGER
{
currentPeriod (1),
lastPeriod (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is an index that specifies which period of time, the next
2 objects refer to.
currentPeriod - the period since last systemResetAllStatsCmd received or
since Start-up (if no systemResetAllStatsCmd was received since
Start-up) until now.
lastPeriod - the period between last two commands of systemResetAllStatsCmd.
- If only one command occurred since Start-up: the period between
Start-up and last command.
- If no command occurred since Start-up: this period will not
actually exist. In this case, he following 5 objects will be 0."
::= { atmVcQoSEntry 1 }
atmVcQoSElapsedTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed Time in seconds.
- for atmVcQoSPeriodRef = currentPeriod:
The period since last systemResetAllStatsCmd received or since Start-up
(if no systemResetAllStatsCmd was received since Start-up) until now.
- for atmVcQoSPeriodRef = lastPeriod:
The value of atmVcQoSElapsedTime when last systemResetAllStatsCmd
was received."
::= { atmVcQoSEntry 2 }
atmVcQoSUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Unavailable Seconds for the reference period (atmVcQoSPeriodRef)."
::= { atmVcQoSEntry 3 }
-- VC PM QoS Table
atmVcPMQoSTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVcPMQoSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The PM VC QoS table."
::= { atmVcPerformance 7 }
atmVcPMQoSEntry OBJECT-TYPE
SYNTAX AtmVcPMQoSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the VC PM QoS table."
INDEX { ifIndex, atmVclVpi, atmVclVci, atmVcPMQoSDirection ,atmVcPMQoSPeriodRef }
::= { atmVcPMQoSTable 1 }
AtmVcPMQoSEntry ::=
SEQUENCE {
atmVcPMQoSDirection INTEGER,
atmVcPMQoSPeriodRef INTEGER,
atmVcPMQoSCLR Gauge32,
atmVcPMQoSCER Gauge32,
atmVcPMQoSCMR Gauge32
}
atmVcPMQoSDirection OBJECT-TYPE
SYNTAX INTEGER
{
forward(2),
backward(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction of performance management."
::= { atmVcPMQoSEntry 1 }
atmVcPMQoSPeriodRef OBJECT-TYPE
SYNTAX INTEGER
{
currentPeriod (1),
lastPeriod (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is an index that specifies which period of time, the next
5 objects refer to.
currentPeriod - the period since last systemResetAllStatsCmd received or
since Start-up (if no systemResetAllStatsCmd was received since
Start-up) until now.
lastPeriod - the period between last two commands of systemResetAllStatsCmd.
- If only one command occurred since Start-up: the period between
Start-up and last command.
- If no command occurred since Start-up: this period will not
actually exist. In this case, he following 5 objects will be 0."
::= { atmVcPMQoSEntry 2 }
atmVcPMQoSCLR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Loss Ratio counter for the reference period (atmVcPMQoSPeriodRef)-
defined in accordance with I.356 , in %.
The value will be multipuled by 100."
::= { atmVcPMQoSEntry 3 }
atmVcPMQoSCER OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Error Ratio counter for the reference period (atmVcPMQoSPeriodRef)
defined in accordance with I.356 , in %.
The value will be multipuled by 100."
::= { atmVcPMQoSEntry 4 }
atmVcPMQoSCMR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Miss-insertion Ratio counter for the reference period (atmVcPMQoSPeriodRef)
defined in accordance with I.356 , cells/sec ."
::= { atmVcPMQoSEntry 5 }
--VC Shaper Statistics Table
atmVcShaperStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVcShaperStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VC shaper statistics table."
::= { atmVcPerformance 8 }
atmVcShaperStatEntry OBJECT-TYPE
SYNTAX AtmVcShaperStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VC shaper statistics table."
INDEX { ifIndex, atmVclVpi, atmVclVci }
::= { atmVcShaperStatTable 1 }
AtmVcShaperStatEntry ::=
SEQUENCE {
atmVcShaperDiscarded Counter32,
atmVcShaperOccupation Integer32,
atmVcShaperMaxOccupation Integer32,
atmVcShaperLevel INTEGER,
atmVcShaperEpdDropped Counter32,
atmVcShaperTotalEpdDropped Counter32
}
atmVcShaperDiscarded OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Cells that were discarded in the shaper on that VCC due
to buffer overflow. This counter counts till it reaches its MAX value
(20 bits) and then rolls over."
::= { atmVcShaperStatEntry 1 }
atmVcShaperOccupation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Cells that are currently stored in the buffer.
This parameter is limited to 20 bits."
::= { atmVcShaperStatEntry 2}
atmVcShaperMaxOccupation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Maximum number of Cells that were stored in the buffer,
since this VC was activated. This parameter is limited to 20 bits."
::= { atmVcShaperStatEntry 3}
atmVcShaperLevel OBJECT-TYPE
SYNTAX INTEGER {
empty (1),
full (2),
below (3),
above (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The occupation of the buffer according to a predefined threshold.
empty - buffer is Empty
full - buffer is Full
below - buffer is Below the threshold
above - buffer is Above the threshold. This is also the trigger to
start EPD\PPD mechanism, if set for the VCC."
::= { atmVcShaperStatEntry 4}
atmVcShaperEpdDropped OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Cells that were dropped in the shaper on that VCC
due to EPD\PPD mechanism in the last second.
This parameter is limited to 24 bits.
Applicable for a EPD/PPD VC only."
::= { atmVcShaperStatEntry 5}
atmVcShaperTotalEpdDropped OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Total number of Cells that were dropped in the shaper on that
VPC due to EPD\PPD mechanism in the last 15 minutes. This counter
automatically reset itself every 15 minutes.
Applicable for a EPD/PPD VC only."
::= { atmVcShaperStatEntry 6}
-- New
-- The agent will keep in this group the date & time corresponding to each interval.
atmIntervalDateTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIntervalDateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The agent will keep in this group the date & time
corresponding to each interval."
::= {atmPerfHistory 3}
atmIntervalDateEntry OBJECT-TYPE
SYNTAX AtmIntervalDateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The date & time for the given interval."
INDEX { atmIntervalDateInterval }
::= { atmIntervalDateTable 1 }
AtmIntervalDateEntry ::=
SEQUENCE {
atmIntervalDateInterval
Integer32,
atmIntervalDateDate
DisplayString,
atmIntervalDateTime
DisplayString
}
atmIntervalDateInterval OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The interval number defining this entry."
::= { atmIntervalDateEntry 1}
atmIntervalDateDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date corresponding to this interval."
::= { atmIntervalDateEntry 2}
atmIntervalDateTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time corresponding to this interval."
::= { atmIntervalDateEntry 3}
--atmNte OBJECT IDENTIFIER ::= {radAtm 3}
atmNteSys OBJECT IDENTIFIER ::= {atmNte 1}
atmNteSysConfig OBJECT IDENTIFIER ::= {atmNteSys 1}
atmNteManagerTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteManagerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Manager Table includes all the NMSs that
receive traps from this agent. A single manager
can receive traps on more than one PVC. The agent
will set implicitly the correct ifIndex, VPI, VCI
values to all relevant entries in the table when
the user changes them for one of the PVCs."
::= { atmNteSysConfig 1 }
atmNteManagerEntry OBJECT-TYPE
SYNTAX AtmNteManagerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A single manager and the PVC for receiving traps."
INDEX { atmNteManagerIP, atmNteManagerPvc}
::= { atmNteManagerTable 1 }
AtmNteManagerEntry ::=
SEQUENCE {
atmNteManagerIP
IpAddress,
atmNteManagerPvc
Integer32,
atmNteManagerIfIndex
Integer32,
atmNteManagerVpi
Integer32,
atmNteManagerVci
Integer32,
atmNteManagerTrapMask
Integer32,
atmNteManagerRowStatus
RowStatus,
atmNteManagerNextHop
IpAddress,
atmNteManagerVlanSupport
INTEGER,
atmNteManagerVlanIdentifier
Integer32,
atmNteManagerVlanFramePriority
Integer32,
atmNteManagerAlarmTrapMask
OCTET STRING,
atmNteManagerConfigPorts
Integer32
}
atmNteManagerIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address of the NMS."
::= { atmNteManagerEntry 1 }
atmNteManagerPvc OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A PVC index. The range is 1..8. There are four PVCs
on the User Port and four PVCs on the Network Port.
The default VPI, VCI values are specified below."
::= { atmNteManagerEntry 2 }
atmNteManagerIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ATM interface index of the management port."
::= { atmNteManagerEntry 3 }
atmNteManagerVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The VPI of the management VCL. Default: 0."
::= { atmNteManagerEntry 4 }
atmNteManagerVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The VCI of the management VCL. Defaults: 32,33,34,35."
::= { atmNteManagerEntry 5 }
atmNteManagerTrapMask OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this attribute determines the type of traps the
agent should mask and not send to this NMS. The
value is differently determined for different products. There are
mainly two methods:
- an integer number, specifying the traps' severity.
- a sum of 2**n, where n is a bit assigned to a certain
masked trap group.
User should consult the product specification, to find out
the method employed."
::= { atmNteManagerEntry 6 }
atmNteManagerRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= {atmNteManagerEntry 7}
atmNteManagerNextHop OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter is relevant to Ethernet out of band
host only (PVC=10).
The Next Hop IP address of the entry route."
::= { atmNteManagerEntry 8 }
atmNteManagerVlanSupport OBJECT-TYPE
SYNTAX INTEGER {
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN support (Tagging).
no - No support to VLAN.
yes - 4 VLAN bytes will be added to the frame."
::= { atmNteManagerEntry 9}
atmNteManagerVlanIdentifier OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN ID. Range is 0..4095."
::= { atmNteManagerEntry 10 }
atmNteManagerVlanFramePriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN Frame priority.Range is 0..7."
::= { atmNteManagerEntry 11 }
atmNteManagerAlarmTrapMask OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object determines the alarm traps that the
agent should mask and not send to this NMS.
The value is an Octet String, where each bit is assigned to a certain
trap.
If the bit = 1, the trap will be masked.
If the bit = 0, the trap will not be masked.
More details on the masked traps exist in the product specification.
For products that do not mask specific traps, the value of the bits will be 0."
::= { atmNteManagerEntry 12 }
atmNteManagerConfigPorts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable defines from which port/s this manager can configure the device.
For IPmux 11 the value of this variable will be according to the ports
combination:
Network =1
User1=2
User2=4
(For Example: All ports = 7)."
::= { atmNteManagerEntry 13 }
atmNteUPLTCR OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Unacceptable ES Limit threshold for Performance Management."
::= {atmNteSysConfig 2}
atmNteDPLTCR OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Degraded ES Limit threshold for Performance Management."
::= {atmNteSysConfig 3}
atmNteSysLogClearAll OBJECT-TYPE
SYNTAX INTEGER { off(2), clear(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the variable to clear(3) removes all entries in the
Log Buffer of the agent. The agent will immediately reset
the variable to off(2)."
::= {atmNteSysConfig 4}
atmNteUSESLTCR OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Unacceptable SES Limit threshold for Performance Management."
::= {atmNteSysConfig 5}
atmNteDSESLTCR OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Degraded ES Limit threshold for Performance Management."
::= {atmNteSysConfig 6}
atmNteProtection OBJECT IDENTIFIER ::= { atmNteSysConfig 8 }
atmNteProtectionMode OBJECT-TYPE
SYNTAX INTEGER {
off (1),
mspOn (2),
pathOn (3),
mspUniOn (4),
mspOneToN (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Protection Mode.
MspOn - Multiplex section protection.
pathOn - High order path protection.
mspUniOn - Multiplex section Uni-directional protection.
mspOneToN - Multiplex section protection."
::= { atmNteProtection 1 }
atmNteProtectionWorkingLink OBJECT-TYPE
SYNTAX INTEGER {
trunk1(2),
trunk2(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the working link when atmNteProtectionMode is off."
::= { atmNteProtection 2 }
atmNteProtectionSwitchLink OBJECT-TYPE
SYNTAX INTEGER {
off(1),
forceSwitch(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ForceSwitch - will force Switching from the working link to the backup link.
Afterwards the agent will set atmNteProtectionSwitchLink back to off(1).
atmNteProtectionMode must be either mspOn or pathOn."
::= { atmNteProtection 3 }
atmNteConfOam OBJECT IDENTIFIER ::= { atmNteSysConfig 9 }
atmNteConfOamSupport OBJECT-TYPE
SYNTAX INTEGER {
intermediate(1),
segmentTermination(2),
endToEndTermination(3),
vpEndToEndVcSegment(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OAM support mode, which determines the device location
in a segment wise."
::= { atmNteConfOam 1 }
atmNteConfOamTransmission OBJECT IDENTIFIER ::= { atmNteConfOam 2 }
atmNteConfOamAIS OBJECT-TYPE
SYNTAX INTEGER {
none(1),
user(2),
network(3),
both(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines if a F4 segment OAM cell is transmitted due
to problems in the other port, i.e. physical layer
alarm or F4 defect. This is valid only when the ACE101
has ATM UNI interfaces in both sides and is configured
for 'Non-Intrusive' mode.
none - AIS is not sent to any of the ports.
user - F4 AIS will be sent toward the user when defect
is detected in the network port.
network - F4 AIS will be sent toward the network when
defect is detected in the user port.
both - F4 AIS will be sent toward the network when defect
is detected in the user port and toward the user
when defect is detected in the network port."
::= { atmNteConfOamTransmission 1 }
atmNteConfOamRDI OBJECT-TYPE
SYNTAX INTEGER {
none(1),
user(2),
network(3),
both(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines if an F4 OAM RDI cell is transmitted due to
physical layer problems in the port (in addition to
F4 RDI cells transmitted due to ATM layer problems).
The type of F4 RDI (Segment or End-to-End) is according
to the ACE-101 OAM mode.
For example, If it is enabled for Network port, then
physical layer defect will initiate the transmission
of F4 RDI cell back to the trunk."
::= { atmNteConfOamTransmission 2 }
atmNteConfOamAddressing OBJECT IDENTIFIER ::= { atmNteConfOam 3 }
atmNteConfLoopbackAddMode OBJECT-TYPE
SYNTAX INTEGER{
off(1),
on(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Loopback addressing mode.
on - will enable loopback addressing.
off - will disable loopback addressing."
::= { atmNteConfOamAddressing 1 }
atmNteConfLoopbackSourceAdd OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(2..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Loopback source address. This field is relevant when
atmNteConfOamAddMode is on."
::= { atmNteConfOamAddressing 2 }
--OAM Table
atmNteConfOamIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteConfOamIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"OAM support per ATM interface."
::= { atmNteConfOam 4 }
atmNteConfOamIfEntry OBJECT-TYPE
SYNTAX AtmNteConfOamIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"."
INDEX { ifIndex }
::= { atmNteConfOamIfTable 1 }
AtmNteConfOamIfEntry ::=
SEQUENCE {
atmNteConfOamIfAisRdi INTEGER
}
atmNteConfOamIfAisRdi OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter controls the generation of F4/F5
AIS and RDI due to lower order problems such as physical
layer problems.
For AIS: Defines if F4/F5 AIS cell is transmitted due
to problems such as physical layer alarm or F4/F5 defect.
This is applicable for all ports .
off - Problems in this port will not trigger F4/F5 AIS
transmition to the ajacent port (e.g. from USER to
NETWORK) of a VPC/VCC.
on - Problems in this port will trigger F4/F5 AIS
transmition to the ajacent port (e.g. from USER
to NETWORK) of a VPC/VCC.
For RDI: Defines if F4/F5 RDI cell will be transmitted due to
physical layer problems in that port (in addition to
F4/F5 RDI cells transmitted due to ATM layer problems).
For example, If it is enabled for Network port, then
physical layer defect will initiate the transmission
of F4/F5 RDI cell back to the trunk.
The type of F4/F5 (Segment or End-to-End) is according
to the configuration of the VPC/VCC."
::= { atmNteConfOamIfEntry 1 }
atmNteConfCAC OBJECT IDENTIFIER ::= { atmNteSysConfig 10 }
atmNteConfCACMode OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CAC support mode.
For ACE2002, the following are the applicable values:
disable(1), enable(2), 10 - 1000."
::= { atmNteConfCAC 1 }
atmNteHostIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteHostIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Host IP interface table."
::= { atmNteSysConfig 11 }
atmNteHostIfEntry OBJECT-TYPE
SYNTAX AtmNteHostIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"."
INDEX { atmNteHostPvcIndex }
::= { atmNteHostIfTable 1 }
AtmNteHostIfEntry ::=
SEQUENCE {
atmNteHostPvcIndex
Integer32,
atmNteHostIP
IpAddress,
atmNteHostMask
IpAddress,
atmNteHostAtmIfIndex
Integer32,
atmNteHostVpi
Integer32,
atmNteHostVci
Integer32,
atmNteHostRowStatus
RowStatus,
atmNteHostRdnVpi
Integer32,
atmNteHostRdnVci
Integer32,
atmNteHostDefaultNextHop
IpAddress,
atmNteHostVlanTagging
INTEGER,
atmNteHostDefaultVlanID
Integer32,
atmNteHostDefaultVlanPriority
Integer32
}
atmNteHostPvcIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A PVC index. The range is 1..10."
::= { atmNteHostIfEntry 1 }
atmNteHostIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The host interface IP address."
::= { atmNteHostIfEntry 2 }
atmNteHostMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The host interface subnet mask."
::= { atmNteHostIfEntry 3 }
atmNteHostAtmIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ATM interface index. Will be 1
for user port, and 2 for network port."
::= { atmNteHostIfEntry 4 }
atmNteHostVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VPI of the PVC connected to that host interface."
::= { atmNteHostIfEntry 5 }
atmNteHostVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VCI of the PVC connected to that host interface."
::= { atmNteHostIfEntry 6 }
atmNteHostRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= { atmNteHostIfEntry 7 }
atmNteHostRdnVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The VPI of the redundant management VCL.
This parameter is applicable only if atmNteRdnManagement=enable(3). "
::= { atmNteHostIfEntry 8 }
atmNteHostRdnVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The VCI of the redundant management VCL.
This parameter is applicable only if atmNteRdnManagement=enable(3). "
::= { atmNteHostIfEntry 9 }
atmNteHostDefaultNextHop OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The host interface Default Next Hop address.
This address will be used as default next hop for
every Bundle mapped to this Host."
::= { atmNteHostIfEntry 10 }
atmNteHostVlanTagging OBJECT-TYPE
SYNTAX INTEGER {
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN Tag support.
no - No support to VLAN.
yes - 4 VLAN bytes will be added
to each frame connected to this Host."
::= { atmNteHostIfEntry 11 }
atmNteHostDefaultVlanID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Default VLAN ID of this Host."
::= { atmNteHostIfEntry 12 }
atmNteHostDefaultVlanPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Default VLAN priority for this Host."
::= { atmNteHostIfEntry 13 }
atmNteShaperMode OBJECT-TYPE
SYNTAX INTEGER {
normal (1),
group (2),
aggregate (3),
vpInbandMng (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shaper Mode.
vpInbandMng - Vcc within a Vp for management."
::= { atmNteSysConfig 12 }
atmNteOutputRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Aggregate shaping output rate in Cells per Seconds units.
Default value is the Network port rate."
::= { atmNteSysConfig 13 }
atmNteTosMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TOS Mode."
::= { atmNteSysConfig 14 }
atmNteTosMask OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter determines the seqence of bits that will be used for TOS.
For ACE101 this parameter is applicable only if atmNteTosMode = enable.
Valid only for IP-TOS process."
::= { atmNteSysConfig 15 }
atmNteTosHighPriority OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(8))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Priorities options are High or Low.
High priority will be represented by bit = 1.
Low priority will be represented by bit = 0.
Each TOS value will be represented by the bit location.
For example, the string for TOS 2, 9, 15 with High priority,
will be:
|0000 0000|... ...|0000 0000|1000 0010|0000 0100|
...98 7654 3210 (Bit #)
8 ... 3 2 1 (Byte #)."
::= { atmNteSysConfig 16 }
atmNtePlugAndPlayActivity OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
offline (2),
online (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Activity control for Manager Plug And Play.
disable - disable the feature.
offline - Automatic learn IP address into offline memory.
online - Automatic learn IP address into online memory. "
::= { atmNteSysConfig 17 }
atmNteSlotUsage OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
user (2),
network (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Applicable to ace2002. Slot 2 might be configured
as user slot or as network slot."
::= { atmNteSysConfig 18 }
atmNteConnectionsMaxNumber OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
max1024 (2),
max2048 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MAX number of connections supported by system.
Setting this parameter will affect the number of MAX intervals supported.
This parameter will affect the system only after reset.
Changing this parameter from high value to a low value, will be accepted by agent
only if the actual used connection <= the desired connection Max number.
Applicable to ace2002. "
::= { atmNteSysConfig 19 }
atmNteDefaultVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default Vpi for management."
::= { atmNteSysConfig 20 }
atmNteDefaultVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default Vci for management."
::= { atmNteSysConfig 21 }
atmNteReservedVpi OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Internal use VPI, where shaperMode=vpInbandMng."
::= { atmNteSysConfig 22 }
atmNteRdnManagement OBJECT-TYPE
SYNTAX INTEGER {
disabled (2),
enabled (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The redundancy management status."
::= { atmNteSysConfig 23 }
atmNtePlugAndPlayIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ifIndex of the Plug and Play VCC."
::= { atmNteSysConfig 24 }
atmNteLoopbackTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Loopback state timeout in minutes. A value of
zero means no timeout (for ever). Default is 5 min."
::= { atmNteSysConfig 25 }
atmNteOamTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is a static table, which is created by agent once
upon initialization. The created entries are actually, only the
supported OAM features.
This table enables addition of new features by adding new entries
rather than adding scalar parameters.
An OAM feature is defined by the indexes values combination."
::= { atmNteSysConfig 26 }
atmNteOamEntry OBJECT-TYPE
SYNTAX AtmNteOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the OAM table.
Each entry in this table will indicate a special OAM."
INDEX {atmNteOamMode, atmNteOamCellType, atmNteOamLevel}
::= { atmNteOamTable 1 }
AtmNteOamEntry ::=
SEQUENCE {
atmNteOamMode
INTEGER,
atmNteOamCellType
INTEGER,
atmNteOamLevel
INTEGER,
atmNteOamEnable
INTEGER
}
atmNteOamMode OBJECT-TYPE
SYNTAX INTEGER
{
endToEnd (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OAM cell path.
endToEnd(1) - the entire path."
::= { atmNteOamEntry 1 }
atmNteOamCellType OBJECT-TYPE
SYNTAX INTEGER
{
aisAndRdi (1),
loopback (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique Indication Signal.
aisAndRdi(1) - Alarm Indication Signal (AIS) and
Remote Defect Indication (RDI) cell.
loopback(2) - Loopback cell."
::= { atmNteOamEntry 2 }
atmNteOamLevel OBJECT-TYPE
SYNTAX INTEGER
{
-- f4 (2),
f5 (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The level of the OAM cell.
-- f4 (2) - VP level,
f5 (3) - VC level."
::= { atmNteOamEntry 3 }
atmNteOamEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter determines if the specified OAM cells
will be enabled."
::= { atmNteOamEntry 4 }
atmNteDefaultLoopbackThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Default OAM Loopback Failure Threshold value
that will be used for configuration."
::= { atmNteSysConfig 27 }
atmNteMaxBurstSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Maximum allowed burst size (cell units).
This object is applicable for each Physical port."
::= { atmNteSysConfig 28 }
atmNteGranularityFactor OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter affects the granularity of the guaranteed
Rate (SCR+MCR) in spaced connection (cell/sec units).
It is also defines the minimum guaranteed rate in spaced
connection."
::= { atmNteSysConfig 29 }
atmNteTotalInputRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates the total input rate of the
device in cells/sec."
::= { atmNteSysConfig 30 }
atmNteTotalOutputRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates the total output rate of the
device in cells/sec."
::= { atmNteSysConfig 31 }
atmAlarmForwardingTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmAlarmForwardingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Alarm Forwarding Mechanism will be operated
for this table entries."
::= { atmNteSysConfig 32 }
atmAlarmForwardingEntry OBJECT-TYPE
SYNTAX AtmAlarmForwardingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in this table is a pair of ports that
the Alarm Forwarding Mechanism is determined for."
INDEX { atmAlarmForwardingFailPort, atmAlarmForwardingToPort }
::= { atmAlarmForwardingTable 1 }
AtmAlarmForwardingEntry ::=
SEQUENCE {
atmAlarmForwardingFailPort
Integer32,
atmAlarmForwardingToPort
Integer32,
atmAlarmForwardingRowStatus
RowStatus,
atmAlarmForwardingFailureLevel
BITS,
atmAlarmForwardingRecoveryMode
INTEGER,
atmAlarmForwardingRecoveryCommand
INTEGER,
atmAlarmForwardingTimeFilterWindow
Unsigned32
}
atmAlarmForwardingFailPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Index of the port on which a fail occurs."
::= { atmAlarmForwardingEntry 1 }
atmAlarmForwardingToPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Index of the port that will be affected
upon the failure of the atmAlarmForwardingFailPort."
::= { atmAlarmForwardingEntry 2 }
atmAlarmForwardingRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= { atmAlarmForwardingEntry 3 }
atmAlarmForwardingFailureLevel OBJECT-TYPE
SYNTAX BITS{
physical (0),
atm (1)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter determines the level of failure
that will operate the Alarm Forwarding Mechanism."
::= { atmAlarmForwardingEntry 4 }
atmAlarmForwardingRecoveryMode OBJECT-TYPE
SYNTAX INTEGER {
manual (1),
automatic (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter determines the Recovery Mode.
manual - The user should stop the RDI transmission
by using the atmAlarmForwardingRecoveryCommand.
automatic - The RDI transmission will be automatically
stopped upon atmAlarmForwardingFailPort
recovery."
::= { atmAlarmForwardingEntry 5 }
atmAlarmForwardingRecoveryCommand OBJECT-TYPE
SYNTAX INTEGER {
off (2),
on (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter is a command. It is applicable when
atmAlarmForwardingRecoveryMode = manual.
on - Will stop the RDI transmission. After setting to 'On'
the agent will set this parameter back to 'Off'."
::= { atmAlarmForwardingEntry 6 }
atmAlarmForwardingTimeFilterWindow OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter determines the Time Filter Window, meaning:
how much time (in seconds) should the alarm exist
in order to start the Alarm Forwarding operation."
::= { atmAlarmForwardingEntry 7 }
atmSysConfigCellTest OBJECT IDENTIFIER ::= { atmNteSysConfig 33 }
atmSysConfigCellTestPort OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An Index of the port on which the cell test
will be sent."
::= { atmSysConfigCellTest 1 }
atmSysConfigCellTestVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The VPI on which the cell test will be sent."
::= { atmSysConfigCellTest 2 }
atmSysConfigCellTestVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The VCI on which the cell test will be sent."
::= { atmSysConfigCellTest 3 }
atmSysConfigCellTestPti OBJECT-TYPE
SYNTAX INTEGER {
user (1),
oamSegment (2),
oamEndToEnd (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The cell type."
::= { atmSysConfigCellTest 4 }
atmSysConfigCellTestClp OBJECT-TYPE
SYNTAX INTEGER {
clp0 (1),
clp1 (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of the Cell."
::= { atmSysConfigCellTest 5 }
atmSysConfigCellTestOamType OBJECT-TYPE
SYNTAX INTEGER {
ais (1),
rdi (2),
cc (3),
lb (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The OAM type of the Cell. This object is applicable
if atmSysConfigCellTestPti = oamSegment/oamEndToEnd ."
::= { atmSysConfigCellTest 6 }
atmSysConfigCellTestPayload OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The payload of the cell. For OAM cell the payload
is set automatically to 6A."
::= { atmSysConfigCellTest 7 }
atmSysConfigCellTestQuantity OBJECT-TYPE
SYNTAX Integer32 (1..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Quantity of cells to send."
::= { atmSysConfigCellTest 8 }
atmSysConfigCellTestSendCmd OBJECT-TYPE
SYNTAX INTEGER {
off (2),
send (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the variable to send(3) perfroms cell test.
The agent will immediately reset the variable to off(2)."
::= { atmSysConfigCellTest 9 }
-- The ATM VP Cross Connect Extension Table
atmVpCrossConnectExtenTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVpCrossConnectExtenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An extension to the ATM VP Cross Connect table
(RFC2515 - atmVpCrossConnectTable)."
::= { atmNteSysConfig 34 }
atmVpCrossConnectExtenEntry OBJECT-TYPE
SYNTAX AtmVpCrossConnectExtenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
AUGMENTS { atmVpCrossConnectEntry }
::= { atmVpCrossConnectExtenTable 1 }
AtmVpCrossConnectExtenEntry ::= SEQUENCE {
atmVpCrossConnectName SnmpAdminString
}
atmVpCrossConnectName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (1..64))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Connection's name."
::= { atmVpCrossConnectExtenEntry 1 }
-- The ATM VC Cross Connect Extension Table
atmVcCrossConnectExtenTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVcCrossConnectExtenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An extension to the ATM VC Cross Connect table
(RFC2515 - atmVcCrossConnectTable)."
::= { atmNteSysConfig 35 }
atmVcCrossConnectExtenEntry OBJECT-TYPE
SYNTAX AtmVcCrossConnectExtenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
AUGMENTS { atmVcCrossConnectEntry }
::= { atmVcCrossConnectExtenTable 1 }
AtmVcCrossConnectExtenEntry ::= SEQUENCE {
atmVcCrossConnectName SnmpAdminString
}
atmVcCrossConnectName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (1..64))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Connection's name."
::= { atmVcCrossConnectExtenEntry 1 }
-- Reserved for atmCongestionThresholdTable ::= { atmNteSysConfig 36 }
atmNteQosMode OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
multipleVc (2),
singleVc (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable defines the QoS Mode.
disable(1) - QoS is disabled.
multipleVc(2) - QoS is enabled and
multiple VCs can be bound per bridge port.
singleVc(3) - QoS is enabled and
only single VC can be bound per bridge port."
::= { atmNteSysConfig 37 }
atmTrafficDescrParamXTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmTrafficDescrParamXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Augment to ATM Traffic Descriptor Parameter Table
(atmTrafficDescrParamTable in ATM-MIB; RFC-2515)."
::= { atmNteSysConfig 38 }
atmTrafficDescrParamXEntry OBJECT-TYPE
SYNTAX AtmTrafficDescrParamXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
AUGMENTS { atmTrafficDescrParamEntry }
::= { atmTrafficDescrParamXTable 1 }
AtmTrafficDescrParamXEntry ::=
SEQUENCE {
atmTrafficDescrParamMode INTEGER
}
atmTrafficDescrParamMode OBJECT-TYPE
SYNTAX INTEGER {
scheduling (1),
schedulingAndShaping (2),
policing (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Mode of the Traffic Descriptor."
::= { atmTrafficDescrParamXEntry 1 }
atmNteSysInfo OBJECT IDENTIFIER ::= {atmNteSys 2}
atmNteIdTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteIdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The IDs of the cards and of the system."
::= { atmNteSysInfo 1 }
atmNteIdEntry OBJECT-TYPE
SYNTAX AtmNteIdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"."
INDEX { atmNteIdIndex}
::= { atmNteIdTable 1 }
AtmNteIdEntry ::=
SEQUENCE {
atmNteIdIndex
Integer32,
atmNteUnitId
Integer32,
atmNteUnitVersion
DisplayString,
atmNteCardType
INTEGER,
atmNteCardStatus
INTEGER,
atmNteCardCmd
INTEGER,
atmNteProgCardType
INTEGER
}
atmNteIdIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An Index of the Unit ID table.
The following units have IDs in this table:
1 - System
2 - ATM Board
3 - User Card
4 - Trunk 1 card
5 - Trunk 2 card
6 - Shaper
7 - Clock Unit
8 - Slot 1 card
9 - Slot 2 card
10 - Slot 3 card
11 - Slot 4 card
12 - Fan1
13 - Fan2
14 - Control Unit."
::= { atmNteIdEntry 1 }
atmNteUnitId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ID of the Unit.
For index = 6, the id will describe the validity
of a shaper in the system: 0 - Shaper Not exist
1 - Shaper exist.
For index = 7, the id will describe the validity
of a clock in the system: 0 - Clock Not exist
1 - Clock exist.
2- Clock exist but failed.
For index = 12,13 the id will describe the functionality
of a FAN1 : 0 - OK
1 - Failed."
::= { atmNteIdEntry 2 }
atmNteUnitVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hardware and Software version
of the module."
::= { atmNteIdEntry 3 }
atmNteCardType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
sc13mR155 (2),
st13sR155 (3),
st13lR155 (4),
utpR155 (5),
cxBncR155 (6),
e3 (7),
t3 (8),
e1 (9),
e1Ltu (10),
fc13lR155 (11),
fc13lhR155 (12),
fc15lhR155 (13),
fc13lE3 (14),
fc13lhE3 (15),
fc15lhE3 (16),
fc13lT3 (17),
fc13lhT3 (18),
fc15lhT3 (19),
t1 (20),
eth (21),
ethE1CesBnc (22),
ethE1CesRj45 (23),
ethT1CesRj45 (24),
e1CesRj45 (25),
e1CesBnc (26),
t1CesRj45 (27),
e14Ces (28),
e14CesRj45 (29),
t14CesRj45 (30),
hdlc4port (31),
hdlcE14CesBnc (32),
hdlcE14CesRj45 (33),
hdlcT14CesRj45 (34),
e1Rj45 (35),
e1Bnc (36),
ethE14CesBnc (37),
ethE14CesRj45 (38),
ethT14CesRj45 (39),
hdlc1portHssi (40),
hdlcHssiE14CesBnc (41),
hdlcHssiE14CesRj45 (42),
hdlcHssiT14CesRj45 (43),
e14ImaRj45 (44),
e14ImaBnc (45),
t14ImaRj45 (46),
ethE3CesBnc (47),
ethT3CesBnc (48),
smSf1R155 (49),
smSf2R155 (50),
sc13sR155 (51),
sc13lR155 (52),
utp25 (53),
sc13lhR155 (54),
sc15lhR155 (55),
sc13ljR155 (56),
sc13lhjR155 (57),
sc15lhjR155 (58),
e18Ces (59),
e18CesRj45 (60),
t18CesRj45 (61),
sc13mR622 (62),
-- st13sR622 (63),
-- st13lR622 (64),
-- utpR622 (65),
-- cxBncR622 (66),
-- fc13lR622 (67),
-- fc13lhR622 (68),
-- fc15lhR622 (69),
-- smSf1R622 (70),
-- smSf2R622 (71),
-- sc13sR622 (72),
sc13lR622 (73),
sc13lhR622 (74),
sc15lhR622 (75),
fr4Port (76),
t3j (77),
fr1Port (78),
hdlc1Port (79),
sc13mR155D (80),
sc13lR155D (81),
fc13lR155D (82),
st13lR155D (83),
sc13lhR155D (84),
fc13lhR155D (85),
st13lhR155D (86),
e18ImaBnc (87),
e18ImaRj45 (88),
t18ImaRj45 (89),
lanUtpE (90),
lanLc13lE (91),
lanLc13mE (92),
e14ImaRj45CfgMode (93),
e14ImaBncCfgMode (94),
t14ImaRj45CfgMode (95),
sc13mR155R (96), --Dual for Redundancy
sc13lR155R (97), --Dual for Redundancy
fc13lR155R (98), --Dual for Redundancy
st13lR155R (99), --Dual for Redundancy
sc13lhR155R (100), --Dual for Redundancy
fc13lhR155R (101), --Dual for Redundancy
st13lhR155R (102), --Dual for Redundancy
fEthUtpD (103),
fEthSmD (104),
fEthMmD (105),
e14CesRj45Unbal (106),
sc13mR155n (107),
sc13lR155n (108),
sc13lhR155n (109),
sc15lhR155n (110),
fc13lR155n (111),
fc13lhR155n (112),
fc15lhR155n (113),
st13lR155n (114),
lanUtp (115),
lanLc13l (116),
lanLc13m (117),
e1FrHdlc (118),
e1FrHdlcUnbal (119),
t1FrHdlc (120),
channelizedT3 (121), --for IP-MUX16
fc15lhR155D (122), --Dual STM-1
sc15lhR155D (123), --Dual STM-1
smSf1R155D (124), --Dual STM-1
smSf2R155D (125), --Dual STM-1
smSf3R155D (126), --Dual STM-1
fc15lhR155R (127), --Dual for Redundancy
sc15lhR155R (128), --Dual for Redundancy
smSf1R155R (129), --Dual for Redundancy
smSf2R155R (130), --Dual for Redundancy
smSf3R155R (131), --Dual for Redundancy
st13lhR155n (132), --New STM-1
smSf1R155n (133), --New STM-1
smSf2R155n (134), --New STM-1
smSf3R155n (135), --New STM-1
t18CesNg (136),
e18CesUnbalNg (137),
e18CesBalNg (138),
t14CesNg (139),
e14CesUnbalNg (140),
e14CesBalNg (141),
t18ImaUniNg (142),
e18ImaUniUnbalNg(143),
e18ImaUniBalNg (144),
t14ImaUniNg (145),
e14ImaUniUnbalNg(146),
e14ImaUniBalNg (147),
t1Ces (148),
e1CesUnbal (149),
e1CesBal (150),
switchedLan (151), --LAN card with ETH switch (usually 4 ports)
channelizedSts1 (152), --Channelized STS1 card (for IP-MUX16)
st13mR155 (153),
st13lhR155 (154),
st15lhR155 (155),
gigabitEthUtp (156),
gigabitEthSfp (157),
fastEthUtp (158),
fourStm1oc3SingleGbe (159),
adsl2Plus1p (160), -- ADSL2+ 1 port
shdsl (161),
gigabitEthCombo (162),
adsl2Plus2p (163), -- ADSL2+ 2 ports
main8Atm155TwoEth (249),
mainChannelized155 (250),
main (251),
control (252),
fan (253),
unknown (254),
empty (255)
-- values 1000 and up are reserved
-- (used by atmNteProgCardType)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The card type."
::= { atmNteIdEntry 4 }
atmNteCardStatus OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
notActive (2),
active (3),
inProgress (4),
empty (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the card in the selected slot.
notActive - Connections are in NotReady state. No configuration is
available for the card. The access to the card HW is blocked.
This state is relevant for an extracted card, and for a case
in which the card was deactivated.
active - The module installed and functions. A card that in this state
can be configured.
inProgress - The status during proccessing of a command from atmNteCardCmd.
empty - No information is valid for the selected slot. This status is
relevant to a case in which the card configaration was deleted,
or in case in which a slot was empty since the device startup."
::= { atmNteIdEntry 5 }
atmNteCardCmd OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
deleteConfig (2),
deactivate (3),
activate (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Command on the card that is installed in the selected slot.
The commands are applicable according to the value of atmNteCardStatus.
See the specification document for details.
deleteConfig - Deletes the card configuration.
deactivate - All the connections state will be changed to NotReady. The card
configuration will be blocked.
activate - Does the same as done upon card insertion: Initiates the relevant
parameters, activates the physical layer, ATM layer and logical
layer."
::= { atmNteIdEntry 6 }
atmNteProgCardType OBJECT-TYPE
SYNTAX INTEGER {
-- values 1...1000 (if needed) should be used
-- the same as in atmNteCardType
fourStm1oc3SingleGbe (159),
adsl2Plus1p (160), -- ADSL2+ 1 port
shdsl (161),
adsl2Plus2p (163), -- ADSL2+ 2 ports
main8Atm155TwoEth (249),
mainChannelized155 (250),
main (251),
control (252),
fan (253),
empty (255),
atm155 (1001),
eth (1002),
channelized155 (1003)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The programmed card type."
::= { atmNteIdEntry 7 }
atmSysPSunits OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of power supply units."
::= { atmNteSysInfo 2 }
atmSysPSunitsInUse OBJECT-TYPE
SYNTAX INTEGER { ps1(2), ps2(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The main power supply in this unit."
::= { atmNteSysInfo 3 }
atmSysFanUnits OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of fan units."
::= { atmNteSysInfo 4 }
atmSysNetPrts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of network ports."
::= { atmNteSysInfo 5 }
atmSysNetPrtInUse OBJECT-TYPE
SYNTAX INTEGER {
trunk1(2),
trunk2(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The network port in use."
::= { atmNteSysInfo 6 }
atmNteBridgingMode OBJECT-TYPE
SYNTAX INTEGER {
accessOnly(1),
accessAndSwitching (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bridging mode can be one of the following:
ATM <> Ethernet - Bridging is between the Ethernet
port and the ATM port (there is no bridging between VCs).
ATM <> Ethernet + ATM - Bridging is done both between
the Ethernet port and the ATM port and also between VCs."
::= { atmNteSysInfo 7}
atmSysStats OBJECT IDENTIFIER ::= { atmNteSysInfo 8 }
atmSysCurrentCdc OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Seconds in which cells dropped was occured in
the current 15 minutes interval."
::= { atmSysStats 1 }
atmSysIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSysIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The system level Interval table."
::= { atmSysStats 2 }
atmSysIntervalEntry OBJECT-TYPE
SYNTAX AtmSysIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"."
INDEX { atmSysIntervalNumber }
::= { atmSysIntervalTable 1 }
AtmSysIntervalEntry ::=
SEQUENCE {
atmSysIntervalNumber
Integer32,
atmSysIntervalCdc
Gauge32
}
atmSysIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { atmSysIntervalEntry 1 }
atmSysIntervalCdc OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Seconds in which cells dropped was occured in
15 minutes interval."
::= { atmSysIntervalEntry 2 }
atmNteEventType OBJECT-TYPE
SYNTAX INTEGER {
ps1NotActive (3),
ps1Active (4),
ps2NotActive (5),
ps2Active (6),
heatAlarmOff (7),
heatAlarmOn (8),
inputAlarm1Off (9),
inputAlarm1On (10),
inputAlarm2Off (11),
inputAlarm2On (12),
inputAlarm3Off (13),
inputAlarm3On (14),
inputAlarm4Off (15),
inputAlarm4On (16),
fan1Ok (17),
fan1Fail (18),
fan2Ok (19),
fan2Fail (20),
invalidLogin (21),
validLogin (22),
powerFailure (23),
writeToFlashFailure (24)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter identifies the event.
On - the problem exist.
Off - the problem not exist.
InvalidLogin - Invalid login on local console.
CorrectLogin - Successful login operation."
::= { atmNteSysInfo 9 }
atmNteIntervalMaxNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAX number of connections intervals supported by system.
This parameter value is a function of atmNteConnectionsMaxNumber
parameter.
This parameter should affect the threshold values selected by user.
Applicable to ace2002."
::= { atmNteSysInfo 10 }
atmNteAlarmType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
ais(2),
rdi(3),
continuityLoss(4),
loopback(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the type of the alarm."
::= { atmNteSysInfo 11 }
atmNteLevel OBJECT-TYPE
SYNTAX INTEGER
{
vp(2),
vc(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the ATM level."
::= { atmNteSysInfo 12 }
atmNteConnectionsNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies a quantity of connections."
::= { atmNteSysInfo 13 }
atmNteTotalLb OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter counts the total number of end-points
that were configured with Loopback (LB)."
::= { atmNteSysInfo 14 }
atmNteTotalCc OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter counts the total number of end-points
that were configured with Continuity Check (CC)."
::= { atmNteSysInfo 15 }
atmNteTotalPm OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter counts the total number of end-points
that were configured with PM."
::= { atmNteSysInfo 16 }
--atmNtePrt OBJECT IDENTIFIER ::= {atmNte 2}
-- Changed
atmNteLoopback OBJECT IDENTIFIER ::= {atmNtePrt 2}
-- The loopback test consists of inserting special OAM cells. This test is started and stopped
-- upon operator request (by using MIB item atmVpConfLoopbackAdminStatus).
-- There are two tables per VP and two tables per VC: the measurements of the current 15 minutes,
-- and the measurement of the last 96 periods of 15 minutes.
atmLoopbackVpTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmLoopbackVpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains parameters for an OAM VP loopback test."
::= {atmNteLoopback 1 }
atmLoopbackVpEntry OBJECT-TYPE
SYNTAX AtmLoopbackVpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table atmLoopbackVpTable."
INDEX {atmLoopbackVpIfIndex,atmLoopbackVpVpi}
::= {atmLoopbackVpTable 1}
AtmLoopbackVpEntry ::=
SEQUENCE {
atmLoopbackVpIfIndex Integer32,
atmLoopbackVpVpi Integer32,
atmLoopbackVpOperStatus INTEGER,
atmLoopbackVpCDV Integer32,
atmLoopbackVpAverageDelay Integer32,
atmLoopbackVpMaxDelay Integer32,
atmLoopbackVpMinDelay Integer32,
atmLoopbackVpErrSessions Integer32
}
atmLoopbackVpIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface index of the ATM layer."
::= {atmLoopbackVpEntry 1}
atmLoopbackVpVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the OAM VPL."
::= {atmLoopbackVpEntry 2}
atmLoopbackVpOperStatus OBJECT-TYPE
SYNTAX INTEGER {
noActive(1),
inProgress(2),
failed(3),
endSuccessfully(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"-noActive(1) means that the loopback test has not been activated for this VP.
-inProgress(2) means that the test has been activated and there is currently no problem.
-failed(3) means there was problem during the test or after having stopped it
-endSuccessfully(4) means that the test was stopped and all was OK."
::= {atmLoopbackVpEntry 3}
atmLoopbackVpCDV OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Delay Variation for this sampling."
::= {atmLoopbackVpEntry 4}
atmLoopbackVpAverageDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Average delay without including lost cells."
::= {atmLoopbackVpEntry 5}
atmLoopbackVpMaxDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum delay without including lost cells."
::= {atmLoopbackVpEntry 6}
atmLoopbackVpMinDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum delay."
::= {atmLoopbackVpEntry 7}
atmLoopbackVpErrSessions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Errored Sessions. Will be updated once in 5 seconds."
::= {atmLoopbackVpEntry 8}
atmLoopbackVcTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmLoopbackVcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains parameters for an OAM VC loopback test."
::= {atmNteLoopback 2 }
atmLoopbackVcEntry OBJECT-TYPE
SYNTAX AtmLoopbackVcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {atmLoopbackVcIfIndex,atmLoopbackVcVpi,atmLoopbackVcVci}
::= {atmLoopbackVcTable 1}
AtmLoopbackVcEntry ::=
SEQUENCE {
atmLoopbackVcIfIndex Integer32,
atmLoopbackVcVpi Integer32,
atmLoopbackVcVci Integer32,
atmLoopbackVcOperStatus INTEGER,
atmLoopbackVcCDV Integer32,
atmLoopbackVcAverageDelay Integer32,
atmLoopbackVcMaxDelay Integer32,
atmLoopbackVcMinDelay Integer32,
atmLoopbackVcErrSessions Integer32
}
atmLoopbackVcIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface index of the ATM layer."
::= {atmLoopbackVcEntry 1}
atmLoopbackVcVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the OAM VCL."
::= {atmLoopbackVcEntry 2}
atmLoopbackVcVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VCI of the OAM VCL."
::= {atmLoopbackVcEntry 3}
atmLoopbackVcOperStatus OBJECT-TYPE
SYNTAX INTEGER {
noActive(1),
inProgress(2),
failed(3),
endSuccessfully(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"-noActive(1) means that the loopback test has not been activated for this VP.
-inProgress(2) means that the test has been activated and there is currently no problem.
-failed(3) means there was problem during the test or after having stopped it
-endSuccessfully(4) means that the test was stopped and all was OK."
::= {atmLoopbackVcEntry 4}
atmLoopbackVcCDV OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Delay Variation for this sampling."
::= {atmLoopbackVcEntry 5}
atmLoopbackVcAverageDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Average delay without including lost cells."
::= {atmLoopbackVcEntry 6}
atmLoopbackVcMaxDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum delay without including lost cells."
::= {atmLoopbackVcEntry 7}
atmLoopbackVcMinDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum delay."
::= {atmLoopbackVcEntry 8}
atmLoopbackVcErrSessions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Errored Sessions. Will be updated once in 5 seconds."
::= {atmLoopbackVcEntry 9}
-- Entirely New
atmLoopbackVpIvlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmLoopbackVpIvlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains parameters for an OAM VP loopback test,
according interval number."
::= {atmNteLoopback 3 }
atmLoopbackVpIvlEntry OBJECT-TYPE
SYNTAX AtmLoopbackVpIvlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { atmLoopbackVpIvlIfIndex, atmLoopbackVpIvlVpi, atmLoopbackVpIvlIvl }
::= { atmLoopbackVpIvlTable 1}
AtmLoopbackVpIvlEntry ::=
SEQUENCE {
atmLoopbackVpIvlIfIndex Integer32,
atmLoopbackVpIvlVpi Integer32,
atmLoopbackVpIvlIvl Integer32,
atmLoopbackVpIvlOperStatus INTEGER,
atmLoopbackVpIvlCDV Integer32,
atmLoopbackVpIvlAverageDelay Integer32,
atmLoopbackVpIvlMaxDelay Integer32,
atmLoopbackVpIvlMinDelay Integer32,
atmLoopbackVpIvlErrSessions Integer32
}
atmLoopbackVpIvlIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface index of the ATM layer."
::= { atmLoopbackVpIvlEntry 1}
atmLoopbackVpIvlVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the OAM VPL."
::= { atmLoopbackVpIvlEntry 2}
atmLoopbackVpIvlIvl OBJECT-TYPE
SYNTAX Integer32(1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The relevant interval number."
::= { atmLoopbackVpIvlEntry 3}
atmLoopbackVpIvlOperStatus OBJECT-TYPE
SYNTAX INTEGER {
noActive(1),
inProgress(2),
failed(3),
endSuccessfully(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"-noActive(1) means that the loopback test has not been activated for this VP during this interval.
-inProgress(2) has no meaning for an ended interval.
-failed(3) means there was problem during the test or after having stopped it
-endSuccessfully(4) means that the test was OK."
::= { atmLoopbackVpIvlEntry 4}
atmLoopbackVpIvlCDV OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Delay Variation for this interval."
::= { atmLoopbackVpIvlEntry 5}
atmLoopbackVpIvlAverageDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Average delay without including lost cells for this interval."
::= { atmLoopbackVpIvlEntry 6}
atmLoopbackVpIvlMaxDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum delay without including lost cells for this interval."
::= { atmLoopbackVpIvlEntry 7}
atmLoopbackVpIvlMinDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum delay for this interval."
::= {atmLoopbackVpIvlEntry 8}
atmLoopbackVpIvlErrSessions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Errored Sessions. Will be updated once in 5 seconds."
::= {atmLoopbackVpIvlEntry 9}
atmLoopbackVcIvlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmLoopbackVcIvlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains parameters for an OAM VC loopback test."
::= {atmNteLoopback 4 }
atmLoopbackVcIvlEntry OBJECT-TYPE
SYNTAX AtmLoopbackVcIvlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {atmLoopbackVcIvlIfIndex, atmLoopbackVcIvlVpi, atmLoopbackVcIvlVci, atmLoopbackVcIvlIvl }
::= {atmLoopbackVcIvlTable 1}
AtmLoopbackVcIvlEntry ::=
SEQUENCE {
atmLoopbackVcIvlIfIndex Integer32,
atmLoopbackVcIvlVpi Integer32,
atmLoopbackVcIvlVci Integer32,
atmLoopbackVcIvlIvl Integer32,
atmLoopbackVcIvlOperStatus INTEGER,
atmLoopbackVcIvlCDV Integer32,
atmLoopbackVcIvlAverageDelay Integer32,
atmLoopbackVcIvlMaxDelay Integer32,
atmLoopbackVcIvlMinDelay Integer32,
atmLoopbackVcIvlErrSessions Integer32
}
atmLoopbackVcIvlIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface index of the ATM layer."
::= {atmLoopbackVcIvlEntry 1}
atmLoopbackVcIvlVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the OAM VCL."
::= {atmLoopbackVcIvlEntry 2}
atmLoopbackVcIvlVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VCI of the OAM VCL."
::= {atmLoopbackVcIvlEntry 3}
atmLoopbackVcIvlIvl OBJECT-TYPE
SYNTAX Integer32(1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The relevant interval number."
::= {atmLoopbackVcIvlEntry 4}
atmLoopbackVcIvlOperStatus OBJECT-TYPE
SYNTAX INTEGER {
noActive(1),
inProgress(2),
failed(3),
endSuccessfully(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"-noActive(1) means that the loopback test has not been activated for this VC during this interval.
-inProgress(2) has no meaning per interval.
-failed(3) means there was problem for this test during this interval.
-endSuccessfully(4) means that the test was OK."
::= {atmLoopbackVcIvlEntry 5}
atmLoopbackVcIvlCDV OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Delay Variation for this interval."
::= {atmLoopbackVcIvlEntry 6}
atmLoopbackVcIvlAverageDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Average delay without including lost cells."
::= {atmLoopbackVcIvlEntry 7}
atmLoopbackVcIvlMaxDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum delay without including lost cells."
::= {atmLoopbackVcIvlEntry 8}
atmLoopbackVcIvlMinDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum delay."
::= {atmLoopbackVcIvlEntry 9}
atmLoopbackVcIvlErrSessions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Errored Sessions. Will be updated once in 5 seconds."
::= {atmLoopbackVcIvlEntry 10}
atmNtePM OBJECT IDENTIFIER ::= {atmNtePrt 3}
atmVpPmTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVpPmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains parameters for VP performance monitoring."
::= {atmNtePM 1 }
atmVpPmEntry OBJECT-TYPE
SYNTAX AtmVpPmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {atmVpPmIfIndex,atmVpPmVpi}
::= {atmVpPmTable 1}
AtmVpPmEntry ::=
SEQUENCE {
atmVpPmIfIndex Integer32,
atmVpPmVpi Integer32,
atmVpPmAdminStatus INTEGER,
atmVpPmDirection INTEGER,
atmVpPmBlockSize Integer32,
atmVpPmRowStatus RowStatus,
atmVpPmSink INTEGER,
atmVpPmSource INTEGER
}
atmVpPmIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface index of the ATM layer."
::= {atmVpPmEntry 1}
atmVpPmVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the Performance Monitoring VPL."
::= {atmVpPmEntry 2}
atmVpPmAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up (2),
down(3),
listenToActivationCells (4),
originateActivationCells (5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"up(2) - Activate PM.
down(3) - Deactivate PM.
listenToActivationCells(4) - .
originateActivationCells(5) - ."
::= {atmVpPmEntry 3}
atmVpPmDirection OBJECT-TYPE
SYNTAX INTEGER {
source(2),
destination(3),
bidirectional(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The direction of PM."
::= {atmVpPmEntry 4}
atmVpPmBlockSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Valid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096,
8192, 16384, 32768."
::= {atmVpPmEntry 5}
atmVpPmRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= {atmVpPmEntry 6}
atmVpPmSink OBJECT-TYPE
SYNTAX INTEGER {
off (1),
fwd (2),
fwdAndBwdReport(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"off (1) - Deactivate PM.
fwd (2) - Activate Forward PM only.
fwdAndBwdReport(3) - Activate Forward PM and Backward reporting."
::= {atmVpPmEntry 7}
atmVpPmSource OBJECT-TYPE
SYNTAX INTEGER {
off (1),
fwd (2),
fwdAndBwdReport(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"off (1) - Deactivate PM.
fwd (2) - Activate Forward PM only.
fwdAndBwdReport(3) - Activate Forward PM and Backward reporting."
::= {atmVpPmEntry 8}
atmVcPmTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVcPmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains parameters for VC performance monitoring."
::= {atmNtePM 2 }
atmVcPmEntry OBJECT-TYPE
SYNTAX AtmVcPmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {atmVcPmIfIndex,atmVcPmVpi,atmVcPmVci}
::= {atmVcPmTable 1}
AtmVcPmEntry ::=
SEQUENCE {
atmVcPmIfIndex Integer32,
atmVcPmVpi Integer32,
atmVcPmVci Integer32,
atmVcPmAdminStatus INTEGER,
atmVcPmDirection INTEGER,
atmVcPmBlockSize Integer32,
atmVcPmRowStatus RowStatus,
atmVcPmSink INTEGER,
atmVcPmSource INTEGER
}
atmVcPmIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface index of the ATM layer."
::= {atmVcPmEntry 1}
atmVcPmVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the Performance Monitoring VCL."
::= {atmVcPmEntry 2}
atmVcPmVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VCI of the PM VCL."
::= {atmVcPmEntry 3}
atmVcPmAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up (2),
down(3),
listenToActivationCells (4),
originateActivationCells (5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"up(2) - Activate PM.
down(3) - Deactivate PM.
listenToActivationCells(4) - .
originateActivationCells(5) - ."
::= {atmVcPmEntry 4}
atmVcPmDirection OBJECT-TYPE
SYNTAX INTEGER { source(2), destination(3), bidirectional(4) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The direction of PM."
::= {atmVcPmEntry 5}
atmVcPmBlockSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Valid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096,
8192, 16384, 32768."
::= {atmVcPmEntry 6}
atmVcPmRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= {atmVcPmEntry 7}
atmVcPmSink OBJECT-TYPE
SYNTAX INTEGER {
off (1),
fwd (2),
fwdAndBwdReport(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"off (1) - Deactivate PM.
fwd (2) - Activate Forward PM only.
fwdAndBwdReport(3) - Activate Forward PM and Backward reporting."
::= {atmVcPmEntry 8}
atmVcPmSource OBJECT-TYPE
SYNTAX INTEGER {
off (1),
fwd (2),
fwdAndBwdReport(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"off (1) - Deactivate PM.
fwd (2) - Activate Forward PM only.
fwdAndBwdReport(3) - Activate Forward PM and Backward reporting."
::= {atmVcPmEntry 9}
atmNteMdl OBJECT IDENTIFIER ::= {atmNte 3}
atmNteMdlConfig OBJECT IDENTIFIER ::= {atmNteMdl 1}
atmNteMdlConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteMdlConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Module configuration table."
::= { atmNteMdlConfig 1 }
atmNteMdlConfigEntry OBJECT-TYPE
SYNTAX AtmNteMdlConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"There is an entry in this table just for those modules that have
parameters that are relevant to module level only."
INDEX {atmNteMdlSlotIndex}
::= {atmNteMdlConfigTable 1}
AtmNteMdlConfigEntry ::=
SEQUENCE {
atmNteMdlSlotIndex Integer32,
atmNteMdlPrtCpuSharing INTEGER,
atmNteMdlInputPriorityMechanism INTEGER
}
atmNteMdlSlotIndex OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The slot number."
::= { atmNteMdlConfigEntry 1}
atmNteMdlPrtCpuSharing OBJECT-TYPE
SYNTAX INTEGER {
equal (2),
port1 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object lets the user decide what will be the CPU sharing
between the ports of the module. This object is applicable for
modules in which the same CPU handles the traffic of all ports.
equal - All ports will have the same CPU resource.
port1 - Port 1 will have higher priority than the other ports."
::= {atmNteMdlConfigEntry 2}
atmNteMdlInputPriorityMechanism OBJECT-TYPE
SYNTAX INTEGER {
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the user to Enable/Disable the Input priority mechanism.
This object is applicable for modules with more than one port, in which the
total ports input may be greater than the port output.
disabled - all LAN VCCs will be transmitted through the same queue (queue 1).
Upon congestion frames will be dropped randomly.
enabled - the user should configure each port/connection priority. Upon
congestion frames will be dropped according to priority."
::= {atmNteMdlConfigEntry 3}
atmGenSystem OBJECT IDENTIFIER ::= {atmGen 2}
--atmGenModules OBJECT IDENTIFIER ::= {atmGen 3} located in ace2002.txt
atmGenSysGen OBJECT IDENTIFIER ::= {atmGenSystem 1}
-- The self test table
atmGenSysSelfTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmGenSysSelfTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing the results of the initial testing of the device."
::= { atmGenSysGen 1 }
atmGenSysSelfTestEntry OBJECT-TYPE
SYNTAX AtmGenSysSelfTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {atmGenSysSelfTestIndex}
::= {atmGenSysSelfTestTable 1}
AtmGenSysSelfTestEntry ::=
SEQUENCE {
atmGenSysSelfTestIndex Integer32,
atmGenSysSelfTestResult DisplayString,
atmGenSysSelfTestModule DisplayString
}
atmGenSysSelfTestIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A running index for the table."
::= { atmGenSysSelfTestEntry 1 }
atmGenSysSelfTestResult OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The results of the initial testing of the device."
::= { atmGenSysSelfTestEntry 2 }
atmGenSysSelfTestModule OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of module on which the test was performed."
::= { atmGenSysSelfTestEntry 3 }
-- The Log clear all
atmGenSysLogClearAll OBJECT-TYPE
SYNTAX INTEGER { off(2),clear(3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the variable to clear(3) removes all entries in the
Log Buffer of the agent. The agent will immediately
reset the variable to off(2)."
::= { atmGenSysGen 2}
-- The Log table
atmGenSysLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmGenSysLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A copy of the log buffer."
::= { atmGenSysGen 3 }
atmGenSysLogEntry OBJECT-TYPE
SYNTAX AtmGenSysLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {atmGenSysLogIndex}
::= {atmGenSysLogTable 1}
AtmGenSysLogEntry ::=
SEQUENCE {
atmGenSysLogIndex Integer32,
atmGenSysLogMessage DisplayString
}
atmGenSysLogIndex OBJECT-TYPE
SYNTAX Integer32 (1..2048)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the log buffer."
::= { atmGenSysLogEntry 1}
atmGenSysLogMessage OBJECT-TYPE
SYNTAX DisplayString (SIZE(80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The log buffer entry message text."
::= { atmGenSysLogEntry 2}
-- Set to default configuration
atmGenSysSetDefaultConfg OBJECT-TYPE
SYNTAX INTEGER { off(2), on(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to on(3), the agent will set all the configuration parameters
to their default values. The variable is then reset to off(2)
by the agent. The agent must be reset for the default configuration
to apply."
::= {atmGenSysGen 4}
-- A Cross Reference table for connections between tables.
atmGenSysCxRefTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmGenSysCxRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A Cross Reference table. The table maintains
an index of an object which is also the table index,
and a counter that indicates how many times this
object was referenced.
When using this table for more than one referenced table,
which uses the same range of indexes, then the index
should be shifted by a unique offset per table.
In ACE2002 this table is used for TD and for FR Desc. Thus,
the index for FR Descriptor is: FR Descriptor index + offset.
The offset is described in the ACE2002 NMS SRS."
::= {atmGenSysGen 5}
atmGenSysCxRefEntry OBJECT-TYPE
SYNTAX AtmGenSysCxRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entries will be added by the agent upon
an entry addition in the referenced tables
(TD table, FR Descriptor etc.)"
INDEX { atmGenSysCxRefIndex }
::= { atmGenSysCxRefTable 1 }
AtmGenSysCxRefEntry ::=
SEQUENCE {
atmGenSysCxRefIndex
Integer32,
atmGenSysCxRefCounter
Gauge32
}
atmGenSysCxRefIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index specifies an entry in the table of the object."
::= { atmGenSysCxRefEntry 1 }
atmGenSysCxRefCounter OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter counts the number of references
that have been made to the object ."
::= { atmGenSysCxRefEntry 2 }
-- Traps
-- System Layer Traps
atmAceStatusChange NOTIFICATION-TYPE
OBJECTS {agnLed,agnIndication}
STATUS current
DESCRIPTION
"The trap is sent every time there is a change in
the state of one of the LEDs."
::= { atmNteEvents 1 }
atmAceAlarmTrap NOTIFICATION-TYPE
OBJECTS {atmInterfaceAlarmStatus}
STATUS current
DESCRIPTION
"The trap is sent whenever there is a transition from a no alarm
state to a state with at least one active alarm. An active alarm
state exists if:
1) The atmInterfaceActiveAlarms vector is different than 0.
2) The atmNteAlarmVpTable contains entries.
3) The atmNteAlarmVcTable contains entries.
The trap is also sent when a transition into the no alarm state
occurs.
The second variable will be atmInterfaceActiveAlarms to
indicate the kind of the alarm.
The trap is not sent more than once in a 10 second interval."
::= { atmNteEvents 2 }
atmAceModuleChangeTrap NOTIFICATION-TYPE
OBJECTS {ifIndex}
STATUS current
DESCRIPTION
"The trap is sent every time a module is changed (Hot swapping).
The second variable will be atmNteCardType to indicate the
type of card that was inserted. The value empty(255) indicates that
a card was taken out."
::= { atmNteEvents 3 }
atmAceRedundancyTrap NOTIFICATION-TYPE
OBJECTS {ifIndex }
STATUS current
DESCRIPTION
"The trap is sent upon change in link as a result of redundancy.
The ifIndex parameter indicates the current active link."
::= { atmNteEvents 4 }
atmAceModuleMismatchTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"The trap is sent upon starting or stopping of
a module mismatch state.
A possible mismatch is when the inserted module is other
than the programmed one."
::= { atmNteEvents 5 }
atmAceSystemTrap NOTIFICATION-TYPE
OBJECTS { atmNteEventType, agnLed, alarmSeverity }
STATUS current
DESCRIPTION
"This trap alerts of major problems in the device."
::= { radSysAtmEvents 6 }
atmAceAlarmForwardingTrap NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState }
STATUS current
DESCRIPTION
"This trap is sent upon starting or stopping Alarm
Forwarding Mechanism."
::= { radSysAtmEvents 7 }
atmAceDateAndTimeRequest NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent upon restart. Upon recieving this trap the NMS will
set the device's date and time. This trap's purpose is to fix a problem
in ACE2002, ACE-2002E, ACE-202. The problem is that the Date and Time
is stored in the NVRAM, and when the NVRAM's battery is empty, the device
loses this information."
::= { radSysAtmEvents 8 }
-- Alarms Traps
atmAceAlarmLOS NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Loss Of Signal."
::= { radSysAtmEvents 16 }
atmAceAlarmLOF NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Loss Of Frame."
::= { radSysAtmEvents 17 }
atmAceAlarmLCD NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Loss of Cell Delineation."
::= { radSysAtmEvents 18 }
atmAceAlarmSLM NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Signal Line Mismatch."
::= { radSysAtmEvents 19 }
atmAceAlarmLOP NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Loss of Pointer."
::= { radSysAtmEvents 20 }
atmAceAlarmLineAIS NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Line AIS."
::= { radSysAtmEvents 21 }
atmAceAlarmPathAIS NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Path AIS."
::= { radSysAtmEvents 22 }
atmAceAlarmLineRDI NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Line RDI."
::= { radSysAtmEvents 23 }
atmAceAlarmPathRDI NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Path RDIand Path RAI(Yellow) for
DS1 interfaces."
::= { radSysAtmEvents 24 }
atmAceAlarmSectionBIP NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Section Bit Interleave Parity."
::= { radSysAtmEvents 25 }
atmAceAlarmLineBIP NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Line Bit Interleave Parity."
::= { radSysAtmEvents 26 }
atmAceAlarmPathBIP NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Path Bit Interleave Parity."
::= { radSysAtmEvents 27 }
atmAceAlarmLineFEBE NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Line Far End Block Error."
::= { radSysAtmEvents 28 }
atmAceAlarmPathFEBE NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Path Far End Block Error."
::= { radSysAtmEvents 29 }
atmAceAlarmPlcpLOF NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates T3 PLCP Loss Of Frame."
::= { radSysAtmEvents 30 }
atmAceAlarmPlcpYELLOW NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates T3 Plcp Yellow."
::= { radSysAtmEvents 31 }
atmAceAlarmPlcpBIP NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates T3 Plcp Bit Interleave Parity."
::= { radSysAtmEvents 32 }
atmAceAlarmPlcpFEBE NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates T3 Plcp Far End Block Error."
::= { radSysAtmEvents 33 }
atmAceAlarmPlcpP1P2 NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates T3 Plcp Parity errors in P1/P2 bytes."
::= { radSysAtmEvents 34 }
atmAceAlarmUAS NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap is sent upon UAS start or end per port."
::= { radSysAtmEvents 35 }
atmAceAlarmCluster NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, atmNteAlarmType, atmNteLevel }
STATUS current
DESCRIPTION
"This trap is sent upon atmNteAlarmType start or end,
for a cluster of VPs/VCs (according to atmNteLevel) with
the same alarm on the same physical port.
This trap replaces sending the same alarm for a big
quantity (the quantity described in the product
specification document) of VPs/VCs in order to prevent
flooding the NMS and the network with traps."
::= { radSysAtmEvents 36 }
atmAceHwFailure NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap is sent upon HW failure per port."
::= { radSysAtmEvents 37 }
atmAceUnavailableBwTrap NOTIFICATION-TYPE
OBJECTS { alarmSeverity, ifAlias, atmConfIfInputRate, atmConfIfOutputRate }
STATUS current
DESCRIPTION
"This trap is sent when Bandwidth allocation is > max possible
value for the installed card.
For ACE2002 this trap will be sent for the following cases:
Card insertion - if the total Input and/or Output Bandwidth is over
allocated, then the specific card rate will be set to 0 and this trap
will be sent with the Input/Output rates values.
Upgrade from former version - when an over allocated Bandwidth is detected,
this trap will be sent with atmConfIfInputRate=atmConfIfOutputRate=0xFFFFFFFF."
::= { radSysAtmEvents 38 }
--
-- OAM LOOPBACK
-- atmAceOAMLoopBackCellRx NOTIFICATION-TYPE
-- OBJECTS { alarmSeverity, alarmState,ifAlias }
-- STATUS current
-- DESCRIPTION
-- "This Trap indicates that a loopback has
-- been activated on device ATM uplink interface
-- by the remote ATM equipment, by means of OAM cells"
-- ::= { radSysAtmEvents 39 }
--
--
-- OAM LOOPBACK
-- atmAceOAMLoopBackCellTx NOTIFICATION-TYPE
-- OBJECTS { alarmSeverity, alarmState,ifAlias }
-- STATUS current
-- DESCRIPTION
-- "This Trap indicates that a loopback has
-- been initiated by local device on ATM uplink interface
-- towards remote ATM equipment, by sending OAM cells."
-- ::= { radSysAtmEvents 15 }
-- VP Layer Traps
-- atmVplVpi have MAX-ACCESS "not-accessible"
-- and cannot be referenced from NOTIFICATION-TYPE clause
-- in SMIV2 so they where removed from following caluses.
-- Dovi Korngut (28/6/00).
atmAceAlarmVpContinuityLoss NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Loss of Continuity Check on a VP Connection."
::= { radSysAtmEvents 40 }
atmAceAlarmVpAISReception NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates AIS Reception on a VP Connection."
::= { radSysAtmEvents 41 }
atmAceAlarmVpRDIReception NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates RDI Reception on a VP Connection."
::= { radSysAtmEvents 42 }
atmAceAlarmVpErroredCells NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Errored Cells on a VP Connection reported by PM."
::= { radSysAtmEvents 43 }
atmAceAlarmVpLostCells NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Lost Cells on a VP Connection reported by PM."
::= { radSysAtmEvents 44 }
atmAceAlarmVpMisinsertedCells NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Misinserted Cells on a VP Connection
reported by PM."
::= { radSysAtmEvents 45 }
atmAceAlarmVpUAS NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap is sent upon UAS start or end per VP."
::= { radSysAtmEvents 46 }
atmAceAlarmVpLoopback NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap is sent upon OAM LoopBack fail status per VP."
::= { radSysAtmEvents 47 }
atmAceAlarmVpGCRAViolation NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates GCRA violation on a VP Connection
reported by UPC device."
::= { radSysAtmEvents 48 }
-- VC Layer Traps
-- atmVclVpi and atmVclVci have MAX-ACCESS "not-accessible"
-- and cannot be referenced from NOTIFICATION-TYPE clause
-- in SMIV2 so they where removed from following caluses.
-- Dovi Korngut (28/6/00).
atmAceAlarmVcContinuityLoss NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Loss of Continuity Check on a VC Connection."
::= { radSysAtmEvents 56 }
atmAceAlarmVcAISReception NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates AIS Reception on a VC."
::= { radSysAtmEvents 57 }
atmAceAlarmVcRDIReception NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates RDI Reception on a VC Connection."
::= { radSysAtmEvents 58 }
atmAceAlarmVcErroredCells NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Errored Cells on a VC Connection reported by PM."
::= { radSysAtmEvents 59 }
atmAceAlarmVcLostCells NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Lost Cells on a VC Connection reported by PM."
::= { radSysAtmEvents 60 }
atmAceAlarmVcMisinsertedCells NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Misinserted Cells on a VC Connection reported
by PM."
::= { radSysAtmEvents 61 }
atmAceAlarmVcUnexpectedCell NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates an unexpected cell from user or network port."
::= { radSysAtmEvents 62 }
atmAceAlarmVcUAS NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap is sent upon UAS start or end per VC."
::= { radSysAtmEvents 63 }
atmAceAlarmVcLoopback NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap is sent upon OAM LoopBack fail status per VC."
::= { radSysAtmEvents 64 }
atmAceAlarmVcGCRAViolation NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates GCRA violation on a VC Connection
reported by UPC device."
::= { radSysAtmEvents 65 }
-- number 80 and up are saved for IMA traps
-- END
-- SENDING OAM VC-AIS CELLS ??
-- This message appears when the LA-110 starts/stop
-- transmitting OAM cells of type VC-AIS to the
-- ATM network the alarm description
-- will be followed with the relevant VP/VC
--
-- SENDING OAM VC-RDI CELLS ???
-- This message appears when the LA-110 start/stop
-- transmitting OAM cells of type VC-RDI to the
-- ATM network the alarm description will be
-- followed with the relevant VP/VC
--
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\hybces.txt
--
-- *************************
-- file : hybCES.txt
--
-- available for ACE20.
--Version: 1.0
--Date: 10/11/97
--By: Ilana Schvetz
--File: v:\doc\rdv\mib\ver470\atm\hybCES.txt
-- Last Update: 08-Mar-01 By Ilana Schvetz
-- Copyright 1996 RAD Data Communications, Ltd.
-- All Rights Reserved.
-- *******************************************************
-- Protocol CES Vcls statistics
-- *******************************************************
--atmGen OBJECT IDENTIFIER ::= { radAtm 2 }
--atmPerfHistory OBJECT IDENTIFIER ::= { atmGen 1 }
--atmPvcPerformance OBJECT IDENTIFIER ::= { atmPerfHistory 2 }
--atmVcPerformance OBJECT IDENTIFIER ::= { atmPvcPerformance 2 }
atmCESAAL1StatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmCESAAL1StatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" This table shows statistics of the structured Circuit-Emulation connections."
::= { atmVcPerformance 5 }
atmCESAAL1StatsEntry OBJECT-TYPE
SYNTAX AtmCESAAL1StatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"defines an entry in the atmCESAAL1StatsTable"
INDEX { ifIndex, atmVclVpi, atmVclVci }
::= { atmCESAAL1StatsTable 1}
AtmCESAAL1StatsEntry ::=
SEQUENCE {
atmCESAAL1SeqErrors
Counter32,
atmCESAAL1HdrErrors
Counter32,
atmCESAAL1PointerReframes
Counter32,
atmCESAAL1BufUnderflows
Counter32,
atmCESAAL1BufOverflows
Counter32
}
atmCESAAL1SeqErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of cells discarded due to wrong sequence number "
::= { atmCESAAL1StatsEntry 1 }
atmCESAAL1HdrErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of cells discarded due to bad AAL1 header error.
this include correctable and uncorrectable CRC, plus bad parity. "
::= { atmCESAAL1StatsEntry 2 }
atmCESAAL1PointerReframes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of events in which the AAL1 reassembler found that an SDT pointer isn't
where it is expected, and the pointer must be reacquired. "
::= { atmCESAAL1StatsEntry 3 }
atmCESAAL1BufUnderflows OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of buffer underflows events. "
::= { atmCESAAL1StatsEntry 4 }
atmCESAAL1BufOverflows OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of buffer overflows events. "
::= { atmCESAAL1StatsEntry 5 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\confvcta.txt
--
-- file : ConfVcTable.txt
--
--Version: 1.0
--Date: 12.11.97
--By: Ilana Schvetz
--File: v:\doc\rdv\mib\ver540\atm\ConfVcTable.txt
--Last Update: 19-Feb-2008 by Shay Harari
-- *******************************************************
-- Configuration Vc Table
-- *******************************************************
--atmNte OBJECT IDENTIFIER ::= { radAtm 3 }
--atmNtePrt OBJECT IDENTIFIER ::= { atmNte 2 }
--atmNtePrtConfig OBJECT IDENTIFIER ::= { atmNtePrt 1 }
atmNteConfVcTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteConfVcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VC configuration table.
The table is an extension to the atmVclTable of
RFC-2515."
::= { atmNtePrtConfig 4 }
atmNteConfVcEntry OBJECT-TYPE
SYNTAX AtmNteConfVcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VC configuration table.
ifIndex of the ATM layer."
INDEX { ifIndex , atmVclVpi, atmVclVci}
::= { atmNteConfVcTable 1 }
AtmNteConfVcEntry ::=
SEQUENCE {
atmConfVcPolicing INTEGER,
atmConfVcCCAdminStatus INTEGER,
atmConfVcLoopbackAdminStatus INTEGER,
atmConfVcLoopbackSinkAddress OCTET STRING,
atmConfVcCongestionControl OCTET STRING,
atmConfVcCCDirection INTEGER,
atmConfVcCreationTime DateAndTime,
atmConfVcOamSupport INTEGER,
atmConfVcCCActivationCtrl INTEGER,
atmConfVcCCOperStatus INTEGER,
atmConfVcLoopbackTraffic INTEGER,
atmConfVcLoopbackFailureInd INTEGER,
atmConfVcLoopbackFailureThreshold Integer32,
atmConfVcOamDirection INTEGER,
atmConfVcName DisplayString,
atmConfVcConnected INTEGER,
atmConfVcOamDescrIndex Integer32,
atmConfVcNoOfUsages Unsigned32
}
atmConfVcPolicing OBJECT-TYPE
SYNTAX INTEGER {
none(1),
police(2),
monitor(3),
shaping(4),
policingAndShaping(5),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Policing method desired for this VCL."
::= { atmNteConfVcEntry 1 }
atmConfVcCCAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(2),
down(3),
source(4), -- agent send Oam CC cells
sink(5), -- agent check received Oam CC cells
listenToActivationCells (6),
originateActivationCells(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"up(2) - Activate Continuity Check (CC).
down(3) - Deactivate CC.
source(4) - Activate OAM CC(Continuity Check) of local agent
( start sending Oam cells to the remote side ).
sink(5) - Activate CC of remote agent ( start receiving Oam cells from
remote side).
listenToActivationCells (6) - Passive listener till gets an activation request
originateActivationCells(7) - Sands Activation cell according to atmConfVcCCDirection."
::= {atmNteConfVcEntry 2}
atmConfVcLoopbackAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(2),
down(3),
llid(4),
segment(5),
endToEnd(6),
segmentLlid(7),
endToEndLlid(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"up(2) - Start loopback OAM cells.
down(3) - Stop sending loopback OAM cells.
For ace2002:
up(2) - Transmitting LB cells with llid all ones
(i.e. FFFF..FF)
down(3) - Not transmitting LB cells.
llid(4) - Transmitting LB cells with llid indicated
in the address field.
segment(5) - Transmitting Segment LB cells with llid
all ones.
endToEnd(6) - Transmitting End to End LB cells with llid
all ones.
segmentLlid(7) - Transmitting Segment LB cells with
llid indicated in the address field.
endToEndLlid(8) - Transmitting LB cells with llid
indicated in the address field.
This parameter value might be in conflict with
atmConfVcOamSupport value, since this parameter is for LB,
while atmConfVcOamSupport is for any other OAM cells."
::= {atmNteConfVcEntry 3}
atmConfVcLoopbackSinkAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(2..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination address.
For ace101: 2 bytes are used.
For ace2002: 16 bytes are used."
::= {atmNteConfVcEntry 4}
atmConfVcCongestionControl OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Each bit indicates a selection of one option
as the following description. All combinations
are possible and legal.
The codes are:
1 - EPD
2 - CLP
4 - EFCI.
For ace2002:
1 - Packet Discard."
::= {atmNteConfVcEntry 5}
atmConfVcCCDirection OBJECT-TYPE
SYNTAX INTEGER {
both (2),
none (3),
source(4),
sink (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"both(2) - Agent sends OAM CC cells and checks received OAM CC cells.
none(3) - Agent does not send and does not check received OAM CC cells.
source(4)- Agent sends OAM CC cells.
sink(5) - Agent checks received OAM CC cells."
::= {atmNteConfVcEntry 6}
atmConfVcCreationTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A date-time in which the VC was created."
::= { atmNteConfVcEntry 7 }
atmConfVcOamSupport OBJECT-TYPE
SYNTAX INTEGER {
intermediate(1),
segmentTermination(2),
endToEndTermination(3),
endToEndAndSegment(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OAM support mode, which determines the device location
in a segment wise.
endToEndAndSegment - In this mode the OAM cells are generated
before the ABM (ATM Buffer Manager), so
that the PCR and CDVT will not be affected."
::= { atmNteConfVcEntry 8 }
atmConfVcCCActivationCtrl OBJECT-TYPE
SYNTAX INTEGER {
manual(1),
activator(2),
listener(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"manual(1) - CC Activation process is disable
activator(2) - ACE-101 initiate CC Activation process
listener(3) - ACE-101 wait to CC Activation request from remote side."
::= { atmNteConfVcEntry 9 }
atmConfVcCCOperStatus OBJECT-TYPE
SYNTAX INTEGER {
initial(1),
up(2),
down(3),
source(4), -- agent send Oam CC cells
sink(5), -- agent check received Oam CC cells
both (8),
timeout (9),
denied (10),
conflict (11),
manual (12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"initial (1) - The CC activation process is not started.
up (2) - Continuity Check (CC) activated.
down (3) - CC deactivated.
source (4) - OAM CC(Continuity Check) of local agent activated.
sink (5) - OAM CC of remote agent activated.
both (8) - OAM CC of local and remote agents activation.
timeout (9) - Timeout occured on receiving answer from
the remote agent.
denied (10) - CC activation process rejected by remote agent.
conflict (11) - local and remote sides requested activation
simultaneously.
manual (12) - OAM CC of local agent activated manually.
"
::= { atmNteConfVcEntry 10 }
atmConfVcLoopbackTraffic OBJECT-TYPE
SYNTAX INTEGER { off(2), on(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter has both command and status meanings:
off(2) - Set to 'Off' will Stop traffic loop. Getting this
value means that the loop is not running.
on (3) - Set to 'On' will start traffic loop. Getting
this value means that the loop is currently running."
::= {atmNteConfVcEntry 11}
atmConfVcLoopbackFailureInd OBJECT-TYPE
SYNTAX INTEGER {
disabled(2),
segmentAis(3),
segmentRdi(4),
segmentAisAndRdi(5),
endToEndAis(6),
endToEndRdi(7),
endToEndAisAndRdi(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows user to define the Indication that will be created upon
a LB cell failure.
disabled(2) - no indication will be created.
segmentAis(3) - will cause Tx of a segment AIS.
segmentRdi(4) - will cause Tx of a segment RDI.
segmentAisAndRdi(5) - will cause Tx of a segment AIS & RDI.
endToEndAis(6) - will cause Tx of an End to End AIS.
endToEndRdi(7) - will cause Tx of an End to End RDI.
endToEndAisAndRdi(8) - will cause Tx of an End to End AIS & RDI.
Default: disabled(2)."
::= {atmNteConfVcEntry 12}
atmConfVcLoopbackFailureThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of the LB failures before starting transmission of the
Indication defined by atmConfVcLoopbackFailureInd.
Range: 1..16. Default: 1."
::= {atmNteConfVcEntry 13}
atmConfVcOamDirection OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
downStream (2),
upStream (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The direction of OAM cell insertion.
downStream(2) - The OAM cell will be inserted in downStream.
upStream(3) - The OAM cell will be inserted in upStream."
::= {atmNteConfVcEntry 14}
atmConfVcName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VC Name."
::= {atmNteConfVcEntry 15}
atmConfVcConnected OBJECT-TYPE
SYNTAX INTEGER {
notConnected (1),
mng (2),
bridgePort (3),
ds0Bundle (4),
atm (5),
pw (6),
routerInterface (7),
qos (8),
other (9),
logicalMac (10)
}
MAX-ACCESS read-write -- Originally read-only
STATUS current
DESCRIPTION
"This object indicates whether this VC is connected
and if connected, what is it connected to.
Originally, it was read-only."
::= {atmNteConfVcEntry 16}
atmConfVcOamDescrIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the VCL's OAM Descriptor index,
according to the OAM Descriptor Configuration Table."
::= {atmNteConfVcEntry 17}
atmConfVcNoOfUsages OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of times this VCL is used."
::= { atmNteConfVcEntry 18 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\ace20.txt
--
-- file : Ace20_v3_5.mib
--
--ACE20-MIB
--
--DEFINITIONS ::= BEGIN
--Title: RAD's ACE20 PRODUCT MIB
--Version: 3.0
--Date: 01/06/99
--By: Eyal Sadovsky & Isac Winter
--File: v:\doc\rdv\mib\ver510\atm\Ace20.txt (1st version)
--Last Update: 16-April-2007 by Yig'al Hachmon
-- IMPORTS
-- OBJECT-TYPE , OBJECT-IDENTITY ,
-- Integer32 , Counter32 FROM SNMPv2-SMI
-- TimeStamp,
-- TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC
-- ifIndex FROM SNMPv2-TC
-- atmVclVpi, atmVclVci,
-- AtmTrafficDescrParamIndex FROM ATM-MIB
-- frPVCEndptDLCIIndex FROM FRNETSERV-MIB;
-- TRAP-TYPE FROM RFC-1215
-- radAtm, agnLed, agnIndication FROM RAD-GEN-MIB;
--RowStatus ::= TEXTUAL-CONVENTION
-- STATUS current
-- DESCRIPTION
-- "."
-- SYNTAX INTEGER {
-- active(1),
-- notInService(2),
-- notReady(3),
-- createAndGo(4),
-- createAndWait(5),
-- destroy(6)
-- }
atmSu OBJECT IDENTIFIER ::= { radAtm 4 } -- RAD ATM Service Unit
atmSuSystem OBJECT IDENTIFIER ::= { atmSu 1 } -- agent system level configuration
-- ***********************************************************************
-- RAD System Software Group
--
-- This table contains software verions parameters.
-- ***********************************************************************
atmSuSystemSwOperStatus OBJECT-TYPE
SYNTAX INTEGER {
disable (1) ,
enable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value indicates if tftp_write operation (for downloading
software from an external host) is allowed by the agent. "
DEFVAL { enable }
::= { atmSuSystem 1 }
atmSuSystemSwSwitchVersionsCmd OBJECT-TYPE
SYNTAX INTEGER {
notActive (1) ,
active (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This command is used to switch beetween software versions stored
in the flash. setting this value to active will reset the agent
and re-activate it with the new version ( only if new version is valid).
on get-request this value will be always notActive. "
::= { atmSuSystem 2 }
-- *******************************************************
-- agent Alarms definitions - two alarms table defined :
-- 1. History Table which hold a buffer contains history events.
-- 2. Mandatory Table hold information of all mandatory alarms
--
-- the following alarms ifIndex defined :
-- 0. system alarms
-- 1. physical DS1 alarms - T1/E1 layer
-- 2. ATM alarms
-- 5. ATM-DXI / Frame-Relay alarms
-- *******************************
atmSuSystemHistoryAlrTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSuSystemHistoryAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"buffer contain history buffer of agent alarms."
::= { atmSuSystem 3 }
atmSuSystemHistoryAlrEntry OBJECT-TYPE
SYNTAX AtmSuSystemHistoryAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Agent alarm history list entry."
INDEX { atmSuSystemHistoryAlrIndex }
::= { atmSuSystemHistoryAlrTable 1}
AtmSuSystemHistoryAlrEntry ::=
SEQUENCE {
atmSuSystemHistoryAlrIndex
Integer32,
atmSuSystemHistoryAlrIfIndex
Integer32,
atmSuSystemHistoryAlrDescription
DisplayString,
atmSuSystemHistoryAlrStatus
INTEGER,
atmSuSystemHistoryAlrOccurrenceTime
DisplayString,
atmSuSystemHistoryAlrVpi
Integer32,
atmSuSystemHistoryAlrVci
Integer32
}
atmSuSystemHistoryAlrIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify an entry in the history alarm table."
::= { atmSuSystemHistoryAlrEntry 1 }
atmSuSystemHistoryAlrIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicates the port on which the alarms occured.
configuration(system) alarms have port index equal to 0. "
::= { atmSuSystemHistoryAlrEntry 2 }
atmSuSystemHistoryAlrDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is a text description of the alarm.
The alarm descipion include alarm code and alarm text."
::= { atmSuSystemHistoryAlrEntry 3 }
atmSuSystemHistoryAlrStatus OBJECT-TYPE
SYNTAX INTEGER {
on (1),
off (2),
event (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of the alarm."
::= { atmSuSystemHistoryAlrEntry 4 }
atmSuSystemHistoryAlrOccurrenceTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicates the date and time of the occurrence
of the event that caused this alarm.
Date and time format: YYYY-MM-DD, HH:MM:SS "
::= { atmSuSystemHistoryAlrEntry 5 }
atmSuSystemHistoryAlrVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicates the ATM VPI of the connection
associated with the event that caused this alarm.
When not applicable, value is 0"
::= { atmSuSystemHistoryAlrEntry 6 }
atmSuSystemHistoryAlrVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicates the ATM VCI of the connection
associated with with the event that caused this alarm.
When not applicable, value is 0 "
::= { atmSuSystemHistoryAlrEntry 7 }
atmSuSystemClearHistoryAlrListCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(1),
on (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON, enforce a clear operation on
the agent history event buffer .
On reading, attribute will always get status 'off' ."
::= { atmSuSystem 4 }
atmSuSystemCurrentAlrTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSuSystemCurrentAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"table which contains all alarms Currently active ( status ON )
in the agent."
::= { atmSuSystem 5 }
atmSuSystemCurrentAlrEntry OBJECT-TYPE
SYNTAX AtmSuSystemCurrentAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Agent alarm list entry."
INDEX { atmSuSystemCurrentAlrIndex }
::= { atmSuSystemCurrentAlrTable 1}
AtmSuSystemCurrentAlrEntry ::=
SEQUENCE {
atmSuSystemCurrentAlrIndex
Integer32,
atmSuSystemCurrentAlrIfIndex
Integer32,
atmSuSystemCurrentAlrDescription
DisplayString
}
atmSuSystemCurrentAlrIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify an entry in the Current alarms table."
::= { atmSuSystemCurrentAlrEntry 1 }
atmSuSystemCurrentAlrIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicates the port on which the alarms occured.
configuration alarms have port index equal to 0. "
::= { atmSuSystemCurrentAlrEntry 2 }
atmSuSystemCurrentAlrDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is a text description of the alarm.
The alarm descipion include alarm code and alarm text."
::= { atmSuSystemCurrentAlrEntry 3 }
-- *******************************************************
-- Agent Config Managers Group
-- *******************************************************
atmSuSystemILMICommunity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Community string for ILMI requests. 10 chars."
::= { atmSuSystem 6 }
atmSuSystemTrapMaxManagers OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of managers that can be registered
for receiving traps and sending requests."
DEFVAL { 10 }
::= { atmSuSystem 7 }
-- *******************************************************
-- Agent AAL1 / AAL2 selection
-- *******************************************************
atmSuSystemAalSelection OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
aal2 (2),
aal1 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select ATM adaptation layers AAL1 or AAL2
Applicable for LA-140"
::= { atmSuSystem 8 }
-- *******************************************************
-- Agent u-Law selection
-- *******************************************************
atmSuSystemCodingLaw OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
aLaw (2),
uLaw (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Method/Law for decoding/encoding the voice
information.
aLaw (2) is the standard Law for E1 links.
uLaw (3) is the standard Law for T1 links.
Coding law is applicable for all the ports in the system"
::= { atmSuSystem 9 }
-- *******************************************************
-- Agent ISDN selection
-- *******************************************************
atmSuSystemISDNDataLinkActivation OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
nonPermanent (2),
permanent (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates data link aactivation for all
ISDN ports in the system.
nonPermanent (2) = non permanent data link activation
permanent (3) = permanent data link activation"
::= { atmSuSystem 10 }
-- *******************************************************
-- Agent ATM Jitter Buffer
-- *******************************************************
atmSuSystemJitterBuffer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The field is set in ms and sets the jitter buffer size.
The jitter buffer adapts the size of the LA140 traffic
to the cdv (cell delay variation) of the ATM network."
::= { atmSuSystem 11 }
-- *******************************************************
-- Agent ATM mode of operation
-- *******************************************************
atmSuSystemOperMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
ima (2),
miniDslam (3),
multipair (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The field indicates device mode of operation:
ima (2) = Inverse Multiplex ATM - ATM traffic is
distributed between links in IMA group.
miniDSLAM (3) => each link serves as separate
ATM interface. (applcable for LA-104)
multiPair (4) - 'SHDSL.bis' multi-pair bonding serve as ATM"
::= { atmSuSystem 12 }
atmSuSystemDSPGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates DSP Gain.
Range of possible values is -12....12.
For LA-110 suset of this range is supported. "
::= { atmSuSystem 13 }
atmSuSystemBundlesApplication OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines application of each bundle .
each bundle is represented by two bits:
00 - TDM over ATM
01 - Frame Relay.
bit 0,1 represents bundle 1
but 2,3 represents bundle 2, etc..."
::= { atmSuSystem 14 }
atmSuSystemMsOperMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
msOverAtm (2),
msOverPsn (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The field indicates device mode of operation:
msOverAtm (2) = Multi Service over ATM.
msOverPsn (3) = Multi Service over PSN (using Pseudo Wires)"
::= { atmSuSystem 15 }
atmSuSystemPwTransportLayer OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
atm (2),
eth (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The field indicates device pseudo wire Transport Layer,
when atmSuSystemMsOperMode = msOverPsn."
::= { atmSuSystem 16 }
-- ****************************************************************
-- ****************************************************************
-- agent ports definitions
-- ****************************************************************
-- ****************************************************************
atmSuPort OBJECT IDENTIFIER ::= { atmSu 2 } -- agent ports definitions
-- ********************************
-- global data port definitions
-- ********************************
--
-- the following table uses parameters which define the physical data port
-- and they are the same for FR and ATM-DXI interfaces
--
atmSuPortDataCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSuPortDataCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Data Port global configuration table.
this table include parametes which are common to the physical port
and not depend on whether the port interface is Frame-Relay or
ATM-DXI."
::= { atmSuPort 1 }
atmSuPortDataCnfgEntry OBJECT-TYPE
SYNTAX AtmSuPortDataCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"the entries at this table describes the configuration
of the Data-Port."
INDEX { ifIndex }
::= { atmSuPortDataCnfgTable 1}
AtmSuPortDataCnfgEntry ::=
SEQUENCE {
atmSuPortDataApplication
INTEGER,
atmSuPortDataRate
INTEGER,
atmSuPortDataDCD
INTEGER,
atmSuPortDataMode
INTEGER,
atmSuPortDataCRC
INTEGER,
atmSuPortDataClock
INTEGER,
atmSuPortDataMaxNoOfConns
Integer32,
atmSuPortDataConfNoOfConns
Integer32,
atmSuPortDataIdleCode
Integer32,
atmSuPortDataInterfaceType
INTEGER,
atmSuPortDataClkPolarity
INTEGER,
atmSuPortDataCtsStatus
INTEGER,
atmSuPortDataRtsStatus
INTEGER
}
atmSuPortDataApplication OBJECT-TYPE
SYNTAX INTEGER
{
frameRelay (1),
atmDxi (2),
bridgedEthernet (3),
smdsDxi (4), -- for future use
aal1Stream (5),
routedEthernet (6),
satop (7),
tdmoIp (8),
frDlci (9),
hdlc (10),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the protocol application which runs
above the physical port."
::= { atmSuPortDataCnfgEntry 1 }
atmSuPortDataRate OBJECT-TYPE
SYNTAX INTEGER
{
r64KBps (1),
r128KBps (2),
r192KBps (3),
r256KBps (4),
r320KBps (5),
r384KBps (6),
r448KBps (7),
r512KBps (8),
r576KBps (9),
r640KBps (10),
r704KBps (11),
r768KBps (12),
r832KBps (13),
r896KBps (14),
r960KBps (15),
r1024KBps (16),
r1088KBps (17),
r1152KBps (18),
r1216KBps (19),
r1280KBps (20),
r1344KBps (21),
r1408KBps (22),
r1472KBps (23),
r1536KBps (24),
r1544network (25), -- take the clock from the T1 network clock for ACE-20T/ACE-2T1
r1600KBps (26),
r1664KBps (27),
r1728KBps (28),
r1792KBps (29),
r1856KBps (30),
r1920KBps (31),
r1984KBps (32),
r2048KBps (33),
r2048network (34), -- take the clock from the E1 network clock for ACE-20E/ACE-2E1
r8192KBps (35), -- for IMXi4
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the operation rate of the port.
AmcdT1 / Ace-20T allowes rates up to 1536KBps ( options 1-12 ),
while AmcdE1 / Ace-20E allowes all options. "
::= { atmSuPortDataCnfgEntry 2 }
atmSuPortDataDCD OBJECT-TYPE
SYNTAX INTEGER
{
off (1),
on (2),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates if the bits CtsCd( Clear-to-send Carry-detect)
are being checked. In AMCD CTS is also checked.
off - ignore DCD signal
on - obey DCD signal"
::= { atmSuPortDataCnfgEntry 3 }
atmSuPortDataMode OBJECT-TYPE
SYNTAX INTEGER
{
nrzi (1),
nrz (2),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This attribute indicates the port mode of sampling data physical. "
::= { atmSuPortDataCnfgEntry 4 }
atmSuPortDataCRC OBJECT-TYPE
SYNTAX INTEGER
{
cRC16 (1),
cRC32 (2),
noCRC (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the type of CRC checking
on receiving/transmiting frames. "
::= { atmSuPortDataCnfgEntry 5 }
atmSuPortDataClock OBJECT-TYPE
SYNTAX INTEGER
{
dce (1),
edce (2), -- for future use
dte (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the clock using for synchronization
for the data port. "
::= { atmSuPortDataCnfgEntry 6 }
atmSuPortDataMaxNoOfConns OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" this object indicates the maximum number of cross-connect
connections allowed beetween the ATM port and the Data Port
identified by IfIndex. "
::= { atmSuPortDataCnfgEntry 7 }
atmSuPortDataConfNoOfConns OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" this object indicates the configured number of cross-connect
connections exist beetween the ATM port and the Data Port
identified by IfIndex. "
::= { atmSuPortDataCnfgEntry 8 }
atmSuPortDataIdleCode OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This attribute is applicable only for application aal1Stream.
It indicates the value to be transmitted whenever the port is idle. "
::= { atmSuPortDataCnfgEntry 9 }
atmSuPortDataInterfaceType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
x21 (2),
v35 (3),
v36 (4),
rs530 (5),
rs232 (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Physical layer interface type. (Configureable or Non-Configureable)"
::= {atmSuPortDataCnfgEntry 10 }
atmSuPortDataClkPolarity OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
normal (2),
inverted (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the clock polarity.
For LA-110/140 this object will be applicable only for
X.21/V.35/data port "
::= {atmSuPortDataCnfgEntry 11}
atmSuPortDataCtsStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off (2), --down
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CTS status - the signal state received from ATM network
(for the local DTE usage).
LA110 receiving RTS down from remote DTE device
via ATM network, will change CTS signal state
to down (off) toward local DTE device"
::= { atmSuPortDataCnfgEntry 12 }
atmSuPortDataRtsStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off (2), --down
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"RTS status - the signal state received from local DTE
(to be forwarded to ATM network).
LA110 receiving RTS down from the local DTE device
will transmit all '1' to ATM (in order to carry the
signaling to remote LA110), and forward it (RTS-down)
to far end through ATM cell (pointer field)."
::= { atmSuPortDataCnfgEntry 13 }
-- *************************************************************
-- agent physical network definitions ( T1/E1 interface )
-- *************************************************************
atmSuPortDs1 OBJECT IDENTIFIER ::= { atmSuPort 2 } -- DS1 definitions
--
-- this table include expansion to the config table in rfc1406
--
atmSuPortDs1CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSuPortDs1CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" This table include expansion configuration to the DS1 physical port."
::= { atmSuPortDs1 1 }
atmSuPortDs1CnfgEntry OBJECT-TYPE
SYNTAX AtmSuPortDs1CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"the entries at this table describes the configuration
of the agent physical."
INDEX { ifIndex }
::= { atmSuPortDs1CnfgTable 1}
AtmSuPortDs1CnfgEntry ::=
SEQUENCE {
atmSuPortDs1CnfgRxSensitivity
INTEGER,
atmSuPortDs1CnfgLBO
INTEGER,
atmSuPortDs1CnfgRestoreTime
INTEGER,
atmSuPortDs1CnfgInbandMng
INTEGER,
atmSuPortDs1CnfgDedicatedTs
Integer32
}
atmSuPortDs1CnfgRxSensitivity OBJECT-TYPE
SYNTAX INTEGER
{
s12dB (1), -- for E1 Interface
s30dB (2), -- for T1/E1 Interface
s36dB (3), -- for T1 Interface
s15dB (4),
s43dB (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the rx line sensetivity parameter used only for
T1/CSU and E1/LTU interfaces."
::= { atmSuPortDs1CnfgEntry 1 }
atmSuPortDs1CnfgLBO OBJECT-TYPE
SYNTAX INTEGER
{
txGain0db(1),
txGain7dot5db (2), --
txGain15db (3), -- for T1/CSU Interface
txGain22dot5db (4), --
len0p133ft (5), --
len133p266ft (6), --
len266p399ft (7), -- for T1/DSU Interface
len399p533ft (8), --
len533p655ft (9), --
unbalanceE1 (10), -- for E1 Interface
balanceE1 (11) --
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the line-Build-Out indicates sensitivity of the DS1 interface.
The user can define if the agent will be CSU or DSU (for T1 only) by choosing the
right option.
On E1 interface this is done by hardware, so this parameter cannot be written. "
::= { atmSuPortDs1CnfgEntry 2 }
atmSuPortDs1CnfgRestoreTime OBJECT-TYPE
SYNTAX INTEGER
{
ccittE1 (1),
restoreT1secFast (2),
restoreT10sec62411 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines the time passing from the disappearance of the loss of
synchronization condition (red alarm) to the restoration of normal
service. The options 1secFast(2) and 10sec62411(3) for E1 interfaces
are proprietary implementation of the T1 standard to the E1 interface."
::= { atmSuPortDs1CnfgEntry 3 }
atmSuPortDs1CnfgInbandMng OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
dedicatedTs (4), -- RAD proprietary
--dedicatedPpp (5),
dedicatedFr (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique number to identify type of
inband management over the link.
For LA-104 and IMXi4, only one port may be used
for inband management "
::= { atmSuPortDs1CnfgEntry 4 }
atmSuPortDs1CnfgDedicatedTs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique number to identify Dedicated Time Slot for inband management
of the T1/E1 port.
It is applicable only when atmSuPortDs1CnfgInbandMng
selected is not off.
1..24 - Dedicated TS of T1
1..31 - Dedicated TS of E1
255 - notApplicable (for agents that do not support this
feature)
Other values are invalid."
::= {atmSuPortDs1CnfgEntry 5}
-- *********************************************************
-- Protocol DS1-CBR Port Definitions
-- *********************************************************
-- this table include parameters in T1/E1 level which
-- are relevant to cbr port only.
atmSuPortDs1CbrCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSuPortDs1CbrCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" This table include expansion configuration to the DS1 physical port."
::= { atmSuPortDs1 2 }
atmSuPortDs1CbrCnfgEntry OBJECT-TYPE
SYNTAX AtmSuPortDs1CbrCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"the entries at this table describes the configuration
of the agent physical."
INDEX { ifIndex }
::= { atmSuPortDs1CbrCnfgTable 1}
AtmSuPortDs1CbrCnfgEntry ::=
SEQUENCE {
atmSuPortDs1CbrIdleCode
Integer32,
atmSuPortDs1CbrRxTimeSlots
TimeSlots,
atmSuPortDs1CbrTxTimeSlots
TimeSlots,
atmSuPortDs1CbrMaxNoOfConns
Integer32,
atmSuPortDs1CbrConfNoOfConns
Integer32,
atmSuPortDs1CbrSignallingSampleTime
INTEGER
}
atmSuPortDs1CbrIdleCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An Idle code which sent on unused time-slots at CBR port ."
::= { atmSuPortDs1CbrCnfgEntry 1 }
atmSuPortDs1CbrRxTimeSlots OBJECT-TYPE
SYNTAX TimeSlots
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicates the time-slots used by the port for receiving.
It uses 32 bits ( in 4 bytes octet string ) for E1 and low 24 bits for T1.
each bit represents a time slot for receiving :
time-slot 0 = bit 0 (LSB - most right bit in last byte),
...
...
time-slot 31 = bit 31 (MSB - most left bit in first byte ).
value '0' indicate unused time-slot and value '1' indicates used time-slot.
note : time-slots '0' and '16' are used for signalling in E1 interface. "
::= { atmSuPortDs1CbrCnfgEntry 2 }
atmSuPortDs1CbrTxTimeSlots OBJECT-TYPE
SYNTAX TimeSlots
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicates the time-slots used by the port for transmiting.
It uses 32 bits for E1 and low 24 bits for T1.
each bit represents a time slot for transmiting :
time-slot 0 = bit 0 (LSB - most right bit in last byte),
...
...
time-slot 31 = bit 31 (MSB - most left bit in first byte ).
value '0' indicate unused time-slot and value '1' indicates used time-slot.
note : time-slots '0' and '16' are used for signalling in E1 interface. "
::= { atmSuPortDs1CbrCnfgEntry 3 }
atmSuPortDs1CbrMaxNoOfConns OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" this object indicates the maximum number of cross-connect
connections allowed beetween the ATM port and the CBR Port
identified by IfIndex. "
::= { atmSuPortDs1CbrCnfgEntry 4 }
atmSuPortDs1CbrConfNoOfConns OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" this object indicates the configured number of cross-connect
connections exist beetween the ATM port and the CBR Port
identified by IfIndex. "
::= { atmSuPortDs1CbrCnfgEntry 5 }
atmSuPortDs1CbrSignallingSampleTime OBJECT-TYPE
SYNTAX INTEGER {
msec100 (1),
msec200 (2),
msec500 (3),
msec1000 (4),
msec1500 (5),
msec2000 (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" determines how often the signalling of the DBCES connections are sampled
and thier activity determined. "
DEFVAL { msec500 }
::= { atmSuPortDs1CbrCnfgEntry 6 }
-- *********************************************************
-- Protocol ATM Definitions
-- *********************************************************
atmSuPortAtm OBJECT IDENTIFIER ::= { atmSuPort 3 } -- ATM expansions to RFC1695
atmSuPortAtmCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSuPortAtmCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains global configuration to the ATM port."
::= { atmSuPortAtm 1 }
atmSuPortAtmCnfgEntry OBJECT-TYPE
SYNTAX AtmSuPortAtmCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object contains information about agent ATM configuration."
INDEX { ifIndex }
::= { atmSuPortAtmCnfgTable 1 }
AtmSuPortAtmCnfgEntry ::= SEQUENCE {
atmSuPortAtmCnfgIdleCellCLP
INTEGER,
atmSuPortAtmCnfgScramble
INTEGER,
atmSuPortAtmSNMPVpi
Integer32,
atmSuPortAtmSNMPVci
Integer32,
atmSuPortAtmSNMPStatus
INTEGER,
atmSuPortAtmILMIStatus
INTEGER,
atmSuPortAtmSNMPIp
IpAddress,
atmSuPortAtmCnfgCDVOptimization
INTEGER,
atmSuPortAtmCnfgShapingMode
INTEGER,
atmSuPortAtmSNMPTrafficDescrIndex
AtmTrafficDescrParamIndex,
atmSuPortAtmTrafficDescrIndex
AtmTrafficDescrParamIndex
}
atmSuPortAtmCnfgIdleCellCLP OBJECT-TYPE
SYNTAX INTEGER {
clp0 (1) , --> ATM Forum
clp1 (2) --> ITU
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines the clp bit value for transmition
in empty time slots."
::= { atmSuPortAtmCnfgEntry 1 }
atmSuPortAtmCnfgScramble OBJECT-TYPE
SYNTAX INTEGER {
enable (1) ,
disable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determined by the standards if the cell will be scrambled or not."
::= { atmSuPortAtmCnfgEntry 2 }
atmSuPortAtmSNMPVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Vcc Vpi for SNMP requests."
::= { atmSuPortAtmCnfgEntry 3 }
atmSuPortAtmSNMPVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Vcc Vci for SNMP requests."
::= { atmSuPortAtmCnfgEntry 4 }
atmSuPortAtmSNMPStatus OBJECT-TYPE
SYNTAX INTEGER {
active (1) ,
notActive (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"value indicates if the SNMP Vcc is available for management."
::= { atmSuPortAtmCnfgEntry 5 }
atmSuPortAtmILMIStatus OBJECT-TYPE
SYNTAX INTEGER {
active (1) ,
notActive (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Value indicates if agent should respond to ILMI requests from the
Atm switch or forward it.
note: when using Atm to Frame-Relay configuration this value should be
active to support ILMI.
when using Atm-AtmDxi configuration the ILMI requests should be
moved forward to the DTE or may be answered by the DCE. "
DEFVAL { active }
::= { atmSuPortAtmCnfgEntry 6 }
atmSuPortAtmSNMPIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interface IP address for SNMP requests."
::= { atmSuPortAtmCnfgEntry 7 }
atmSuPortAtmCnfgCDVOptimization OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"value indicates if optimization of CDV (Cell Delay Varation)
is enbabled."
::= { atmSuPortAtmCnfgEntry 8 }
atmSuPortAtmCnfgShapingMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
sw (2),
hwNcits1 (3), -- HW Shaping, APC with NCITS = 1
hwNcits2 (4) -- HW Shaping, APC with NCITS = 2
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ATM Shaping mode.
Three possible values:
SW Shaping.
HW Shaping - APC with NCITS = 1.
HW Shaping - APC with NCITS = 2
The difference between the two hardware modes
is in the connection cell granularity
and maximum bandwidth (BW):
* For NCITS=1, the granularity is of one cell
and the max. BW is the uplink BW,
* For NCITS=2, the granularity is of every two cells
and the max. BW is half of the uplink BW."
::= { atmSuPortAtmCnfgEntry 9 }
atmSuPortAtmSNMPTrafficDescrIndex OBJECT-TYPE
SYNTAX AtmTrafficDescrParamIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the row
in the atmTrafficDescrParamTable which
applies to the transmit direction of the VCL."
::= { atmSuPortAtmCnfgEntry 10 }
atmSuPortAtmTrafficDescrIndex OBJECT-TYPE
SYNTAX AtmTrafficDescrParamIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the row
in the atmTrafficDescrParamTable which
applies to whole ATM WAN port."
::= { atmSuPortAtmCnfgEntry 11 }
-- *************************************************************
-- RAD private ATM Interface statistics table. The table adds
-- more columns to the RFC1695 atmInterfaceConfTable
-- *************************************************************
atmSuPortAtmIfStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSuPortAtmIfStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table contains additional statistics information about
the ATM interface."
::= { atmSuPortAtm 2 }
atmSuPortAtmIfStatsEntry OBJECT-TYPE
SYNTAX AtmSuPortAtmIfStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM Interface statistics table."
INDEX { ifIndex }
::= { atmSuPortAtmIfStatsTable 1 }
AtmSuPortAtmIfStatsEntry ::= SEQUENCE {
atmSuPortAtmRxClp0Cells
Counter32,
atmSuPortAtmRxClp1Cells
Counter32,
atmSuPortAtmRxEfciSetCells
Counter32,
atmSuPortAtmRxOamCells
Counter32,
atmSuPortAtmTxClp0Cells
Counter32,
atmSuPortAtmTxClp1Cells
Counter32,
atmSuPortAtmTxEfciSetCells
Counter32,
atmSuPortAtmTxOamCells
Counter32
}
atmSuPortAtmRxClp0Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of cells received with correct
HECs and CLP=0 and not misrouted"
::= { atmSuPortAtmIfStatsEntry 1 }
atmSuPortAtmRxClp1Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of cells received with correct
HEC's and CLP=1 and not misrouted."
::= { atmSuPortAtmIfStatsEntry 2 }
atmSuPortAtmRxEfciSetCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of cells received with EFCI bit set by
the Agent"
::= { atmSuPortAtmIfStatsEntry 3 }
atmSuPortAtmRxOamCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of OAM cells received with correct HECs."
::= { atmSuPortAtmIfStatsEntry 4 }
atmSuPortAtmTxClp0Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of cells transmitted with CLP=0."
::= { atmSuPortAtmIfStatsEntry 5 }
atmSuPortAtmTxClp1Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of cells transmitted with CLP=1."
::= { atmSuPortAtmIfStatsEntry 6 }
atmSuPortAtmTxEfciSetCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of cells transmitted with EFCI bit set by
the Agent"
::= { atmSuPortAtmIfStatsEntry 7 }
atmSuPortAtmTxOamCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted OAM cells."
::= { atmSuPortAtmIfStatsEntry 8 }
-- **************************************************************
-- RAD Vcl Statistics table. The table adds more columns to
-- the RFC1695 atmVclTable
-- **************************************************************
atmSuPortAtmVclStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSuPortAtmVclStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table contains additional information about
the ATM Vcl end points."
::= { atmSuPortAtm 3 }
atmSuPortAtmVclStatsEntry OBJECT-TYPE
SYNTAX AtmSuPortAtmVclStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM Vcl statistics table.
For Vpl statistics, use atmVclVci = 65536
(maximum valid value of atmVclVci +1)"
INDEX {ifIndex, atmVclVpi, atmVclVci }
::= { atmSuPortAtmVclStatsTable 1 }
AtmSuPortAtmVclStatsEntry ::= SEQUENCE {
atmSuPortAtmVclStatsRxCells
Counter32,
atmSuPortAtmVclStatsRxClp0Cells
Counter32,
atmSuPortAtmVclStatsRxClp1Cells
Counter32,
atmSuPortAtmVclStatsRxDiscardsCells
Counter32,
atmSuPortAtmVclStatsTxCells
Counter32,
atmSuPortAtmVclStatsTxClp0Cells
Counter32,
atmSuPortAtmVclStatsTxClp1Cells
Counter32,
atmSuPortAtmVclStatsRxTotalAISCells
Counter32,
atmSuPortAtmVclStatsRxTotalCCCells
Counter32,
atmSuPortAtmVclStatsTotalSuccLoopbacks
Counter32,
atmSuPortAtmVclStatsTotalFailLoopbacks
Counter32,
atmSuPortAtmVclStatsRxTotalRDICells
Counter32,
atmSuPortAtmVclStatsTotalLOCSeconds
Counter32,
atmSuPortAtmVclStatsRxTotalLoopbackRequests
Counter32,
atmSuPortAtmVclStatsTxTotalAISCells
Counter32,
atmSuPortAtmVclStatsTxTotalCCCells
Counter32,
atmSuPortAtmVclStatsTxTotalRDICells
Counter32,
atmSuPortAtmVclStatsTxTotalLoopbackResponses
Counter32,
atmSuPortAtmVclStatsTxTotalLoopbackRequests
Counter32,
atmSuPortAtmVclStatsRxTotalLoopbackResponses
Counter32
}
atmSuPortAtmVclStatsRxCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells received with
correct HEC's."
::= { atmSuPortAtmVclStatsEntry 1 }
atmSuPortAtmVclStatsRxClp0Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of cells received with correct
HEC's and CLP=0."
::= { atmSuPortAtmVclStatsEntry 2 }
atmSuPortAtmVclStatsRxClp1Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of cells received with correct
HEC's and CLP=1."
::= { atmSuPortAtmVclStatsEntry 3 }
atmSuPortAtmVclStatsRxDiscardsCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of cells, in ingress direction,
discarded due to policing violation."
::= { atmSuPortAtmVclStatsEntry 4 }
atmSuPortAtmVclStatsTxCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells transmitted."
::= { atmSuPortAtmVclStatsEntry 5 }
atmSuPortAtmVclStatsTxClp0Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of cells transmitted with CLP=0."
::= { atmSuPortAtmVclStatsEntry 6 }
atmSuPortAtmVclStatsTxClp1Cells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of cells transmitted with CLP=1."
::= { atmSuPortAtmVclStatsEntry 7 }
atmSuPortAtmVclStatsRxTotalAISCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of AIS cells received on the VC."
::= { atmSuPortAtmVclStatsEntry 8 }
atmSuPortAtmVclStatsRxTotalCCCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of Continuity Check cells that were
received on the VC."
::= { atmSuPortAtmVclStatsEntry 9 }
atmSuPortAtmVclStatsTotalSuccLoopbacks OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of loopbacks that were requested by the ACE20
and for which there was a response (not supported)."
::= { atmSuPortAtmVclStatsEntry 10 }
atmSuPortAtmVclStatsTotalFailLoopbacks OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of loopbacks that were requested by the ACE20
and for which there was no response (not supported)."
::= { atmSuPortAtmVclStatsEntry 11 }
atmSuPortAtmVclStatsRxTotalRDICells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of RDI cells received on a VC."
::= { atmSuPortAtmVclStatsEntry 12 }
atmSuPortAtmVclStatsTotalLOCSeconds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of seconds during which there was loss of
continuity on the VC - no data and no continuity check cells
were received on the VC whilst it was in 'sink' continuity
check mode."
::= { atmSuPortAtmVclStatsEntry 13 }
atmSuPortAtmVclStatsRxTotalLoopbackRequests OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of loopback requests received by the ACE20 on a VC."
::= { atmSuPortAtmVclStatsEntry 14 }
atmSuPortAtmVclStatsTxTotalAISCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of AIS cells that were transmitted on a VC."
::= { atmSuPortAtmVclStatsEntry 15 }
atmSuPortAtmVclStatsTxTotalCCCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of continuity check cells that were transmitted on
a VC (when there is no data cells and the connection is in
'source' continuity check mode)."
::= { atmSuPortAtmVclStatsEntry 16 }
atmSuPortAtmVclStatsTxTotalRDICells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of RDI cells transmitted on a VC."
::= { atmSuPortAtmVclStatsEntry 17 }
atmSuPortAtmVclStatsTxTotalLoopbackResponses OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of loopback responses that were transmitted as a
result of loopback requests received."
::= { atmSuPortAtmVclStatsEntry 18 }
atmSuPortAtmVclStatsTxTotalLoopbackRequests OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of loopback requests that were transmitted by the ACE20 on a VC."
::= { atmSuPortAtmVclStatsEntry 19 }
atmSuPortAtmVclStatsRxTotalLoopbackResponses OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of loopback responses that were received as a
result of loopback transmitted by the ACE20."
::= { atmSuPortAtmVclStatsEntry 20 }
-- **************************************************************
-- RAD AAL1 Vcc Statistics table. This table includes all AAL1
-- connections which are not from CES/DBCES type.
-- **************************************************************
-- Use atmCESAAL1StatsTable instead atmAAL1StatsTable
--atmAAL1StatsTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF atmAAL1StatsEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table contains AAL1 VCC performance parameters."
-- ::= { atmSuPortAtm 4 }
--
--atmAAL1StatsEntry OBJECT-TYPE
-- SYNTAX atmAAL1StatsEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This list contains the AAL1 VCC performance parameters."
-- INDEX { ifIndex }
-- ::= { atmAAL1StatsTable 1 }
--
--atmAAL1StatsEntry ::= SEQUENCE {
-- atmVclVpi
-- Integer32,
-- atmVclVci
-- Integer32,
-- atmAAL1HdrErrors
-- Counter32,
-- atmAAL1SeqErrors
-- Counter32
-- }
--
--atmAAL1VclVpi OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The SNMP Vpi of this entry."
-- ::= { atmAAL1StatsEntry 1 }
--
--atmAAL1VclVci OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The SNMP Vci of this entry."
-- ::= { atmAAL1StatsEntry 2 }
--
--atmAAL1HdrErrors OBJECT-TYPE
-- SYNTAX Counter32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The count of the number of AAL1 header errors detected,
-- including those corrected. Header errors include correctable
-- and uncorrectable CRC, plus bad parity."
-- ::= { atmAAL1StatsEntry 3 }
--
--atmAAL1SeqErrors OBJECT-TYPE
-- SYNTAX Counter32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "Number of AAL1 sequence violations which the AAL Convergence
-- sublayer interprets as a misinserted cell, as defined by
-- ITU-T I.363.1."
-- ::= { atmAAL1StatsEntry 4 }
-- **********************************************************
-- **********************************************************
-- Protocol FR Definitions
-- **********************************************************
-- **********************************************************
atmSuPortFr OBJECT IDENTIFIER ::= { atmSuPort 4 }
-- **********************************************************
-- the Frame Relay Logical Port Group
-- **********************************************************
atmSuPortFrLportTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSuPortFrLportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table Contains configuration parameters of the Frame-Relay
port and has expansion to frLportTable in RFC1604 MIB."
::= { atmSuPortFr 1 }
atmSuPortFrLportEntry OBJECT-TYPE
SYNTAX AtmSuPortFrLportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Frame Relay Logical Port
Information table."
INDEX { ifIndex }
::= { atmSuPortFrLportTable 1 }
AtmSuPortFrLportEntry ::=
SEQUENCE {
atmSuPortFrLportSNMPDlci
Integer32,
atmSuPortFrLportSNMPStatus
INTEGER,
atmSuPortFrLportVCSigProtocol
INTEGER,
atmSuPortFrLportVCSigProcedure
INTEGER,
atmSuPortFrLportCLLM
INTEGER,
atmSuPortFrLportSNMPIp
IpAddress
}
atmSuPortFrLportSNMPDlci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SNMP Dlci of this entry."
::= { atmSuPortFrLportEntry 1 }
atmSuPortFrLportSNMPStatus OBJECT-TYPE
SYNTAX INTEGER {
active (1) ,
notActive (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"value indicates if SNMP over FR is available for management."
::= { atmSuPortFrLportEntry 2 }
atmSuPortFrLportVCSigProtocol OBJECT-TYPE
SYNTAX INTEGER {
none(1),
ccittQ933A(2),
ansiT1617D(3),
lmi(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the Local
In-Channel Signaling Protocol that is used for
this frame relay UNI/NNI logical port."
DEFVAL { none }
::= { atmSuPortFrLportEntry 3 }
atmSuPortFrLportVCSigProcedure OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
u2nnet(2),
u2nuser(3),
bidirect(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the Local
In-Channel Signaling Procedure that is used for
this UNI/NNI logical port. The UNI/NNI logical
port can be performing user-to-network
network-side and user-to-network user-side procedures
or bidirectional procedures.
this parameter gets value 'notApplicable when the VCSigProtocol is none"
::= { atmSuPortFrLportEntry 4 }
atmSuPortFrLportCLLM OBJECT-TYPE
SYNTAX INTEGER {
active (1),
notActive(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" indicate if the configuration is supporting CLLM ( Consolidated Link
Layer Management ) ."
::= { atmSuPortFrLportEntry 5 }
atmSuPortFrLportSNMPIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interface IP address of this entry."
::= { atmSuPortFrLportEntry 6 }
-- ***************************************************************
-- RAD Frame Relay Statistics table. The table add more
-- columns to the RFC1604 frPVCEndptTable
-- ***************************************************************
atmSuPortFrPvcEndptTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSuPortFrPvcEndptEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table contains additional information about
the Frame Relay end point."
::= { atmSuPortFr 2 }
atmSuPortFrPvcEndptEntry OBJECT-TYPE
SYNTAX AtmSuPortFrPvcEndptEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for FR end-point statistics ( expansion to RFC 1604 )."
INDEX { ifIndex, frPVCEndptDLCIIndex }
::= { atmSuPortFrPvcEndptTable 1 }
AtmSuPortFrPvcEndptEntry ::= SEQUENCE {
atmSuPortFrPvcEndptTxFECNs
Counter32,
atmSuPortFrPvcEndptTxBECNs
Counter32,
atmSuPortFrPvcEndptTxDEs
Counter32,
atmSuPortFrPvcEndptRxFECNs
Counter32,
atmSuPortFrPvcEndptRxBECNs
Counter32
}
atmSuPortFrPvcEndptTxFECNs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of frames transmited with FECN ( Forward Explicit
Congestion Notification )."
::= { atmSuPortFrPvcEndptEntry 1 }
atmSuPortFrPvcEndptTxBECNs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of frames transmited with BECN ( Backward Explicit
Congestion Notification )."
::= { atmSuPortFrPvcEndptEntry 2 }
atmSuPortFrPvcEndptTxDEs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of frames transmited with the DE ( Discarded Eligible ) bit set."
::= { atmSuPortFrPvcEndptEntry 3 }
atmSuPortFrPvcEndptRxFECNs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of frames received with FECN ( Forward Explicit
Congestion Notification )."
::= { atmSuPortFrPvcEndptEntry 4 }
atmSuPortFrPvcEndptRxBECNs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of frames received with BECN ( Backward Explicit
Congestion Notification )."
::= { atmSuPortFrPvcEndptEntry 5 }
-- ***************************************************************
-- ATM-DXI Managment LMI Addresses
-- ***************************************************************
atmSuPortDxi OBJECT IDENTIFIER ::= { atmSuPort 5 } -- ATM-DXI definitions
atmSuPortDxiConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSuPortDxiConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains ATM-DXI managment
address (DFA) ending at the local agent.
only LMI managment supported for ATM-DXI."
::= { atmSuPortDxi 1 }
atmSuPortDxiConfEntry OBJECT-TYPE
SYNTAX AtmSuPortDxiConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object contains information about agent Dxi interface."
INDEX { ifIndex }
::= { atmSuPortDxiConfTable 1 }
AtmSuPortDxiConfEntry ::= SEQUENCE {
atmSuPortDxiPortMode
INTEGER,
atmSuPortDxiSigProtocol
INTEGER,
atmSuPortDxiSigDfa
Integer32
}
atmSuPortDxiPortMode OBJECT-TYPE
SYNTAX INTEGER {
mode1a (1),
mode1b (2),
mode2 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the dxi mode being used by
the atm dxi port."
::= { atmSuPortDxiConfEntry 1 }
atmSuPortDxiSigProtocol OBJECT-TYPE
SYNTAX INTEGER {
none (1) ,
lmi (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value indicates if we using LMI signalling protocol
or not using any signalling ."
::= { atmSuPortDxiConfEntry 2 }
atmSuPortDxiSigDfa OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Signalling Dfa address .
the default LMI Dfa defined for LMI by the AtmForum is 0."
DEFVAL { 0 }
::= { atmSuPortDxiConfEntry 3 }
-- **************************************************************
atmSuPortCmdTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSuPortCmdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"General commands to be done on agent's ports."
::= { atmSuPort 6 }
atmSuPortCmdEntry OBJECT-TYPE
SYNTAX AtmSuPortCmdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object contains entry information."
INDEX { ifIndex }
::= { atmSuPortCmdTable 1 }
AtmSuPortCmdEntry ::= SEQUENCE {
atmSuResetPortStatsCmd
INTEGER,
atmSuResetConnsStatsCmd
INTEGER
}
atmSuResetPortStatsCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(1),
on (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" reset statistics of port."
::= { atmSuPortCmdEntry 1 }
atmSuResetConnsStatsCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(1),
on (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" reset statistics of all cross connections attached to this port.
set-request is allowed only on the DATA Ports .
for get-request value is always 'off' "
::= { atmSuPortCmdEntry 2 }
-- **********************************************************
-- **********************************************************
-- Protocol Ethernet Definitions
-- **********************************************************
-- **********************************************************
atmSuPortEther OBJECT IDENTIFIER ::= { atmSuPort 7 }
-- **********************************************************
-- the Ethernet Port Group
-- **********************************************************
atmSuPortEtherTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSuPortEtherEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table Contains configuration parameters of the Ethernet port."
::= { atmSuPortEther 1 }
atmSuPortEtherEntry OBJECT-TYPE
SYNTAX AtmSuPortEtherEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Ethernet Port Information table."
INDEX { ifIndex }
::= { atmSuPortEtherTable 1 }
AtmSuPortEtherEntry ::=
SEQUENCE {
atmSuPortEtherIP
IpAddress,
atmSuPortEtherMask
IpAddress,
atmSuPortEtherDefaultGateWayIp
IpAddress,
atmSuPortEtherDefaultCrossConnectId
Integer32,
atmSuPortEtherDefaultGatewayStatus
INTEGER,
atmSuPortEtherSNMPStatus
INTEGER,
atmSuPortEtherFragmentation
INTEGER,
atmSuPortEtherRIPMode
INTEGER,
atmSuPortEtherBridgingMode
INTEGER,
atmSuPortEtherARPTimeout
Integer32,
atmSuPortEtherAgingTime
Integer32,
atmSuPortEtherPppOEEnable
INTEGER,
atmSuPortEtherStatus
INTEGER
}
atmSuPortEtherIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interface IP address for SNMP requests."
::= { atmSuPortEtherEntry 1 }
atmSuPortEtherMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interface IP address mask for SNMP requests."
::= { atmSuPortEtherEntry 2 }
atmSuPortEtherDefaultGateWayIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Ethernet bridge default gateway IP address."
::= { atmSuPortEtherEntry 3 }
atmSuPortEtherDefaultCrossConnectId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default Cross Connect Id. "
::= { atmSuPortEtherEntry 4 }
atmSuPortEtherDefaultGatewayStatus OBJECT-TYPE
SYNTAX INTEGER {
active (1) ,
notActive (2) ,
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default Gateway Status."
::= { atmSuPortEtherEntry 5 }
atmSuPortEtherSNMPStatus OBJECT-TYPE
SYNTAX INTEGER {
active (1) ,
notActive (2) ,
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value indicates if the SNMP of Ethernet bridge interface is available
for management."
::= { atmSuPortEtherEntry 6 }
atmSuPortEtherFragmentation OBJECT-TYPE
SYNTAX INTEGER {
no (2),
yes (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fragmentation. When application is not router value must be 'notApplicable'."
::= { atmSuPortEtherEntry 7 }
atmSuPortEtherRIPMode OBJECT-TYPE
SYNTAX INTEGER {
rip1 (1),
rip2 (2),
rip1And2 (3),
none (4),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RIP Mode. When application is not router value must be 'notApplicable'."
::= { atmSuPortEtherEntry 8 }
atmSuPortEtherBridgingMode OBJECT-TYPE
SYNTAX INTEGER {
accessOnly (1),
accessAndSwitching (2),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bridging mode can be one of the following:
ATM <> Ethernet - Bridging is between the Ethernet
port and the ATM port (there is no bridging between VCs).
ATM <> Ethernet + ATM - Bridging is done both between
the Ethernet port and the ATM port and also between VCs.
When application is router value must be 'notApplicable'."
::= { atmSuPortEtherEntry 9 }
atmSuPortEtherARPTimeout OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ARP Timeout. When application is not router or when
this object is not applicable, value must be 0."
DEFVAL { 5 }
::= { atmSuPortEtherEntry 10 }
atmSuPortEtherAgingTime OBJECT-TYPE
SYNTAX Integer32 (0..1000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The timeout period in seconds for aging out stored information.
valid values are 10...1000000. The value of (0) has
the special meaning - not applicable. "
::= { atmSuPortEtherEntry 11 }
atmSuPortEtherPppOEEnable OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or Disable transparent PPP over ethernet bridge.
When PPP over Ethernet is enabled, non PPP traffic is
blocked by the bridge."
::= { atmSuPortEtherEntry 12 }
atmSuPortEtherStatus OBJECT-TYPE
SYNTAX INTEGER {
active (1),
createAndGo(4),
destroy (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows user to add/remove entries to/from this table.
It will be supported only by certain devices.
destroy - may not be possible for certain interfaces."
::= { atmSuPortEtherEntry 13 }
-- *************************************************************
-- *************************************************************
-- Cross-Connect connections definitions
-- *************************************************************
-- *************************************************************
atmSuCrossConnect OBJECT IDENTIFIER ::= { atmSu 3 } -- cross connect definitions
-- *************************************************************
-- RAD ATM to Frame Relay endpoints Connections group
-- *************************************************************
atmSuCrossConnectAtmFr OBJECT IDENTIFIER ::= { atmSuCrossConnect 1 }
--AtmSuCrossConnectAtmFrDescrIndex ::= TEXTUAL-CONVENTION
-- STATUS current
-- DESCRIPTION
-- "The value of this object identifies the row
-- in the atmSuCrossConnectAtmFrDescrTable."
-- SYNTAX Integer32
atmSuCrossConnectAtmFrDescriptor
OBJECT IDENTIFIER ::= { atmSuCrossConnectAtmFr 1 }
-- *************************************************************
-- RAD ATM to Frame Relay connection types group
-- The group contains ATM to Frame Relay connection modes,
-- defining the connection parameters.
-- *************************************************************
atmFrCrossConnectNetwork OBJECT IDENTIFIER ::= { atmSuCrossConnectAtmFrDescriptor 1 }
-- atmFrCrossConnectNetwork OBJECT-IDENTITY
-- STATUS current
-- DESCRIPTION
-- "This connection descriptor is network connection mode.
-- The use of the parameter vector for this type:
-- Clp2De : ATM CLP to Frame Relay DE mapping mode.
-- The following values are allowed:
-- convSscs- The DE bit of the FR-SSCS PDU is copied Q.922
-- DE field.
-- conv- If one or more ATM cells belonging to a frame has
-- its CLP bit set, or the DE field
-- of the FR-SSCS PDU is set, then the DE bit
-- of the Q.922 core frame is set.
-- De2Clp: Frame Relay DE to ATM CLP mapping mode.
-- ( DE bit is always copied unchanged to the FR-SSCS PDU header ).
-- The following values are allowed:
-- conv - The Q.922 DE bit is mapped to every CLP bit.
-- always0- CLP bit is always 0.
-- always1- CLP bit is always 1.
-- Fecn2Efci : Not used
-- MappingMode: Not used
-- "
-- ::= { atmSuCrossConnectAtmFrDescriptor 1}
-- atmFrCrossConnectService OBJECT-IDENTITY
-- STATUS current
-- DESCRIPTION
-- "This connection descriptor is service connection mode.
-- The use of the parameter vector for this type:
-- Clp2De : ATM CLP to Frame Relay DE mapping mode.
-- The following values are allowed:
-- conv - If one or more ATM cells belonging to a frame has
-- its CLP bit set, then the DE bit
-- of the Q.922 core frame is set.
-- always0- The DE bit is always 0.
-- always1- The DE bit is always 1.
-- De2Clp : Frame Relay DE to ATM CLP mapping mode.
-- The following values are allowed:
-- conv - The DE bit is mapped to every CLP bit.
-- always0- CLP bit is always 0
-- always1- CLP bit is always 1
-- Fecn2Efci: Frame Relay FECN to ATM EFCI mapping mode.
-- The following values are allowed:
-- conv - The FECN bit is mapped to every EFCI bit.
-- always0- EFCI bit is always 0.
-- MappingMode: Upper Layer mapping mode.
-- The following values are allowed:
-- transparent - trasparent mode
-- translation - translation mode
-- note : value 0 for parameter means that it is not supported .
-- "
-- ::= { atmSuCrossConnectAtmFrDescriptor 2 }
atmFrCrossConnectService OBJECT IDENTIFIER ::= { atmSuCrossConnectAtmFrDescriptor 2 }
-- *************************************************************
-- RAD ATM to Frame Relay connection descriptor table.
-- *************************************************************
atmFrDescrTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmFrDescrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains information on ATM to FR Connection
descriptor types, and their associated parameters."
::= { atmSuCrossConnectAtmFr 2 }
atmFrDescrEntry OBJECT-TYPE
SYNTAX AtmFrDescrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This list contains ATM to FR Connection descriptor
type, and its associated parameters."
INDEX { atmFrDescrIndex }
::= { atmFrDescrTable 1}
AtmFrDescrEntry ::= SEQUENCE {
atmFrDescrIndex
Integer32, -- was AtmSuCrossConnectAtmFrDescrIndex,
atmFrDescrType
OBJECT IDENTIFIER,
atmFrDescrClp2De
INTEGER,
atmFrDescrDe2Clp
INTEGER,
atmFrDescrFecn2Efci
INTEGER,
atmFrDescrMappingMode
INTEGER,
atmFrDescrRowStatus
RowStatus
}
atmFrDescrIndex OBJECT-TYPE
SYNTAX Integer32 -- was AtmSuCrossConnectAtmFrDescrIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to identify the row index of
the ATM to FR connection descriptor table."
::= { atmFrDescrEntry 1 }
atmFrDescrType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies the type
of the ATM to FR Connection descriptor.
The type may indicate Network connection descriptor
or a Service connection descriptor with one or more
parameters.
These parameters are specified as a parameter
vector, in the corresponding instances of the
objects:
atmFrDescrClp2De
atmFrDescrDe2Clp
atmFrDescrFecn2Efci
atmFrDescrMappingMode."
::= { atmFrDescrEntry 2 }
atmFrDescrClp2De OBJECT-TYPE
SYNTAX INTEGER
{
convSscs (1),
conv (2),
always0 (3),
always1 (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The first parameter of the ATM to FR Connection
descriptor used according to the value of atmFrDescrType."
DEFVAL { conv }
::= { atmFrDescrEntry 3 }
atmFrDescrDe2Clp OBJECT-TYPE
SYNTAX INTEGER
{
conv (1),
always0 (2),
always1 (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The second parameter of the ATM to FR Connection
descriptor used according to the value of atmFrDescrType."
DEFVAL { conv }
::= { atmFrDescrEntry 4 }
atmFrDescrFecn2Efci OBJECT-TYPE
SYNTAX INTEGER
{
conv (1),
always0 (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The third parameter of the ATM to FR Connection
descriptor used according to the value of atmFrDescrType."
DEFVAL { conv }
::= { atmFrDescrEntry 5 }
atmFrDescrMappingMode OBJECT-TYPE
SYNTAX INTEGER
{
transparent (1),
translation (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The fourth parameter of the ATM to FR Connection
descriptor used according to the value of atmFrDescrType."
DEFVAL { translation }
::= { atmFrDescrEntry 6 }
atmFrDescrRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create,
modify or delete a row in this table."
DEFVAL { active }
::= { atmFrDescrEntry 7 }
-- *************************************************************
-- RAD ATM to Frame Relay connection table group
-- *************************************************************
-- RAD ATM to Frame Relay connection table.
atmSuCrossConnectAtmFrIndexNext OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an appropriate value to
be used for atmFrCnfgCrossConnectIndex when creating
entries in the atmFrCnfgTable. The value
0 indicates that no unassigned entries are
available. To obtain the atmFrCnfgCrossConnectIndex
value for a new entry, the manager issues a
management protocol retrieval operation to obtain
the mandatory value of this object. After each
retrieval, the agent should modify the value to
the next unassigned index."
::= { atmSuCrossConnectAtmFr 3 }
atmFrCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmFrCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines virtual connections between ATM and
Frame Relay endpoints."
::= { atmSuCrossConnectAtmFr 4 }
atmFrCnfgEntry OBJECT-TYPE
SYNTAX AtmFrCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry defines virtual connection between ATM and
Frame Relay endpoint."
INDEX {
atmFrCnfgCrossConnectIndex,
atmFrCnfgAtmIfIndex,
atmFrCnfgAtmVpi,
atmFrCnfgAtmVci,
atmFrCnfgFrIfIndex,
atmFrCnfgDlci
}
::= { atmFrCnfgTable 1 }
AtmFrCnfgEntry ::= SEQUENCE {
atmFrCnfgCrossConnectIndex
Integer32,
atmFrCnfgAtmIfIndex
Integer32,
atmFrCnfgAtmVpi
Integer32,
atmFrCnfgAtmVci
Integer32,
atmFrCnfgFrIfIndex
Integer32,
atmFrCnfgDlci
Integer32,
atmFrCnfgAdminStatus
INTEGER,
atmFrCnfgOperStatus
INTEGER,
atmFrCnfgLastChange
TimeStamp,
atmFrCnfgMappingDescrIndex
Integer32, -- was AtmSuCrossConnectAtmFrDescrIndex,
atmFrCnfgSscsDlci
Integer32,
atmFrCnfgTrafficDescrIndex
AtmTrafficDescrParamIndex,
atmFrCnfgPriority
INTEGER,
atmFrCnfgRowStatus
RowStatus,
atmFrCnfgAllocatedBuffers
Integer32
}
atmFrCnfgCrossConnectIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value to identify this cross-connect."
::= { atmFrCnfgEntry 1 }
atmFrCnfgAtmIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex associated to the ATM interface."
::= { atmFrCnfgEntry 2 }
atmFrCnfgAtmVpi OBJECT-TYPE
SYNTAX Integer32 (1..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Vpi number of the ATM end point."
::= { atmFrCnfgEntry 3 }
atmFrCnfgAtmVci OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Vci number of the ATM end point."
::= { atmFrCnfgEntry 4 }
atmFrCnfgFrIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex associated to the Frame Relay
interface."
::= { atmFrCnfgEntry 5 }
atmFrCnfgDlci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DLCI number of the FR end point."
::= { atmFrCnfgEntry 6 }
atmFrCnfgAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the connection status requested by the user."
::= { atmFrCnfgEntry 7 }
atmFrCnfgOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Operational status of the connection."
::= { atmFrCnfgEntry 8 }
atmFrCnfgLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time the ATM to FR
connection entered its mandatory operational state.
If the mandatory state was entered prior to the last
re-initialization of the local network management
subsystem, then this object contains a zero value."
::= { atmFrCnfgEntry 9 }
atmFrCnfgMappingDescrIndex OBJECT-TYPE
SYNTAX Integer32 -- was AtmSuCrossConnectAtmFrDescrIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies the row
in the atmFrDescrTable."
::= { atmFrCnfgEntry 10 }
atmFrCnfgSscsDlci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The DLCI number given to the SSCS Sub-layer for network interworking only
( the default value is 'atmFrCnfgDlci' ).
for Service Interworking do not implement this variable."
::= { atmFrCnfgEntry 11 }
-- atmFrCnfgBitRate OBJECT-TYPE
-- SYNTAX INTEGER
-- {
-- ubr (1) ,
-- vbr (2) ,
-- abr (3)
-- }
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "The traffic bit rate mode for this connection.
-- note :setting this value is allowed only to point2point connections.
-- for many2one connections is being set by the
-- atmFrCrossConnectMany2OneRootsTable and this field is equal
-- to this setting."
-- ::= { atmFrCnfgEntry 12 }
atmFrCnfgTrafficDescrIndex OBJECT-TYPE
SYNTAX AtmTrafficDescrParamIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies the row
in the atmTrafficDescrParamTable which
applies to the transmit direction of the VCL.
note :setting this value is allowed only to point2point connections.
for many2one connections is being set by the
atmFrCrossConnectMany2OneRootsTable and this field is equal
to this setting."
::= { atmFrCnfgEntry 12 }
atmFrCnfgPriority OBJECT-TYPE
SYNTAX INTEGER
{
highPriority (1),
mediumPriority (2),
lowPriority (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object define the priority of connection.
The first parameter affects the transmition of cells in Conjested
network is the bitRate( Cbr has the highest priority and then Vbr,Ubr )
In connections with the same bitRate this object will define the priority."
::= { atmFrCnfgEntry 13 }
atmFrCnfgRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create
a new row or modify or delete an
existing row in this table."
::= { atmFrCnfgEntry 14 }
atmFrCnfgAllocatedBuffers OBJECT-TYPE
SYNTAX Integer32 (10..217)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables user to limit the amount of buffers
used by the connection.
The limit set by this object will give
the effect of a virtual buffer pool per connection.
The user can allocate between 10 to 217 buffers
to every connection. By default the limit is 50 buffers.
Sum of limits allocated to all connections
must not exceed the total amount of available buffers.
Whenever a connection exceeds it's buffer limit
due to congestion or burst - traffic is discarded"
DEFVAL { 50 }
::= { atmFrCnfgEntry 15 }
atmFrMaxMany2OneConnsPerVcc OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Maximum Number of many2one cross-connect connections
allowed per Vcc ."
::= { atmSuCrossConnectAtmFr 5 }
-- *************************************************************
-- RAD ATM to ATM-DXI endpoints Connections group
-- *************************************************************
atmSuCrossConnectAtmDxi OBJECT IDENTIFIER ::= { atmSuCrossConnect 2 }
atmSuCrossConnectAtmDxiIndexNext OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an appropriate value to
be used for atmDxiCnfgCrossConnectIndex when creating
entries in the atmDxiCnfgTable. The value
0 indicates that no unassigned entries are
available. To obtain the atmDxiCnfgCrossConnectIndex
value for a new entry, the manager issues a
management protocol retrieval operation to obtain
the mandatory value of this object. After each
retrieval, the agent should modify the value to
the next unassigned index."
::= { atmSuCrossConnectAtmDxi 1 }
atmDxiCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmDxiCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines virtual connections between ATM and
ATM-DXI endpoints."
::= { atmSuCrossConnectAtmDxi 2 }
atmDxiCnfgEntry OBJECT-TYPE
SYNTAX AtmDxiCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry defines virtual connection between ATM and
ATM-DXI endpoint."
INDEX {
atmDxiCnfgCrossConnectIndex,
atmDxiCnfgAtmIfIndex,
atmDxiCnfgAtmVpi,
atmDxiCnfgAtmVci,
atmDxiCnfgDxiIfIndex,
atmDxiCnfgDfa
}
::= { atmDxiCnfgTable 1 }
AtmDxiCnfgEntry ::= SEQUENCE {
atmDxiCnfgCrossConnectIndex
Integer32,
atmDxiCnfgAtmIfIndex
Integer32,
atmDxiCnfgAtmVpi
Integer32,
atmDxiCnfgAtmVci
Integer32,
atmDxiCnfgDxiIfIndex
Integer32,
atmDxiCnfgDfa
Integer32,
atmDxiCnfgAdminStatus
INTEGER,
atmDxiCnfgOperStatus
INTEGER,
atmDxiCnfgLastChange
TimeStamp,
atmDxiCnfgTrafficDescrIndex
AtmTrafficDescrParamIndex,
atmDxiCnfgPriority
INTEGER,
atmDxiCnfgRowStatus
RowStatus
}
atmDxiCnfgCrossConnectIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value to identify this cross-connect."
::= { atmDxiCnfgEntry 1 }
atmDxiCnfgAtmIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex associated to the ATM interface."
::= { atmDxiCnfgEntry 2 }
atmDxiCnfgAtmVpi OBJECT-TYPE
SYNTAX Integer32 (1..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Vpi number of the ATM end point."
::= { atmDxiCnfgEntry 3 }
atmDxiCnfgAtmVci OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Vci number of the ATM end point."
::= { atmDxiCnfgEntry 4 }
atmDxiCnfgDxiIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex associated to the atm-dxi interface."
::= { atmDxiCnfgEntry 5 }
atmDxiCnfgDfa OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DFA number of the DXI end point."
::= { atmDxiCnfgEntry 6 }
atmDxiCnfgAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The requested state of the ATM to DXI connection."
::= { atmDxiCnfgEntry 7 }
atmDxiCnfgOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The real operational status of the ATM to DXI connection."
::= { atmDxiCnfgEntry 8 }
atmDxiCnfgLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time the ATM to DXI
connection entered its mandatory operational state.
If the mandatory state was entered prior to the last
re-initialization of the local network management
subsystem, then this object contains a zero value.
Same value define both direction ( Atm2Dxi and Dxi2Atm )."
::= { atmDxiCnfgEntry 9 }
-- atmDxiCnfgBitRate OBJECT-TYPE
-- SYNTAX INTEGER
-- {
-- ubr (1) ,
-- vbr (2) ,
-- abr (3)
-- }
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "The traffic bit rate mode for this connection."
-- ::= { atmDxiCnfgEntry 10 }
atmDxiCnfgTrafficDescrIndex OBJECT-TYPE
SYNTAX AtmTrafficDescrParamIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies the row
in the atmTrafficDescrParamTable which
applies to the transmit direction of the VCL."
::= { atmDxiCnfgEntry 10 }
atmDxiCnfgPriority OBJECT-TYPE
SYNTAX INTEGER
{
highPriority (1),
mediumPriority (2),
lowPriority (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object define the priority of connection.
The first parameter affects the transmition of cells in Conjested
network is the bitRate( Cbr has the highest priority and then Vbr,Ubr )
In connections with the same bitRate this object will define the priority."
::= { atmDxiCnfgEntry 11 }
atmDxiCnfgRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or
modify or delete an existing row in this table."
::= { atmDxiCnfgEntry 12 }
-- *************************************************************
-- RAD ATM to CBR Connections group (excluded CES/DBCES
-- connections which are handled in the CES table)
-- *************************************************************
atmSuAtmCbr OBJECT IDENTIFIER ::= { atmSuCrossConnect 3 }
atmCbrCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmCbrCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines AAL1 virtual connections (not CES)
between ATM port and DS1-CBR port."
::= { atmSuAtmCbr 1 }
atmCbrCnfgEntry OBJECT-TYPE
SYNTAX AtmCbrCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry defines virtual connection between ATM port and
DS1-CBR port."
INDEX {
atmCbrCnfgAtmIfIndex,
atmCbrCnfgAtmVpi,
atmCbrCnfgAtmVci,
atmCbrCnfgCbrIfIndex
}
::= { atmCbrCnfgTable 1 }
AtmCbrCnfgEntry ::= SEQUENCE {
atmCbrCnfgAtmIfIndex
Integer32,
atmCbrCnfgAtmVpi
Integer32,
atmCbrCnfgAtmVci
Integer32,
atmCbrCnfgCbrIfIndex
Integer32,
atmCbrCnfgAdminStatus
INTEGER,
atmCbrCnfgOperStatus
INTEGER,
atmCbrCnfgLastChange
TimeStamp,
atmCbrCnfgAAL1Signalling
INTEGER,
atmCbrCnfgRxTimeSlots
TimeSlots,
atmCbrCnfgRxBytesPerCell
Integer32,
atmCbrCnfgTxTimeSlots
TimeSlots,
atmCbrCnfgTxBytesPerCell
Integer32,
atmCbrCnfgParity
INTEGER,
atmCbrCnfgRowStatus
RowStatus,
atmCbrCnfgService
INTEGER
}
atmCbrCnfgAtmIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex associated to the ATM interface."
::= { atmCbrCnfgEntry 1 }
atmCbrCnfgAtmVpi OBJECT-TYPE
SYNTAX Integer32 (1..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Vpi number of the ATM end point."
::= { atmCbrCnfgEntry 2 }
atmCbrCnfgAtmVci OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Vci number of the ATM end point."
::= { atmCbrCnfgEntry 3 }
atmCbrCnfgCbrIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex associated to the logical interface of DS0s bundle
or to ifIndex of one of the data ports."
::= { atmCbrCnfgEntry 4 }
atmCbrCnfgAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up (1),
down (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The requested status of the connection."
::= { atmCbrCnfgEntry 5 }
atmCbrCnfgOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up (1),
down (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The real operational status of the connection."
::= { atmCbrCnfgEntry 6 }
atmCbrCnfgLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time the ATM to CBR
connection entered its mandatory operational state.
If the mandatory state was entered prior to the last
re-initialization of the local network management
subsystem, then this object contains a zero value.
Same value define both direction ( Atm2Cbr and Cbr2Atm )."
::= { atmCbrCnfgEntry 7 }
atmCbrCnfgAAL1Signalling OBJECT-TYPE
SYNTAX INTEGER
{
off (1),
on (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Not in use. Must be always 'off'."
::= { atmCbrCnfgEntry 8 }
atmCbrCnfgRxTimeSlots OBJECT-TYPE
SYNTAX TimeSlots
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This value indicates the time-slots used by this connection for receiving.
It uses 32 bits for E1 and low 24 bits for T1.
each bit represents a time slot for receiving :
time-slot 0 = bit 0 (LSB - most right bit in last byte),
...
...
time-slot 31 = bit 31 (MSB - most left bit in first byte ).
value '0' indicate unused time-slot and value '1' indicates used time-slot.
On set-request the user indicates the time-slot he needs for requested ATM-Vcc
by putting '1' to the right bits.
note : time-slots '0' and '16' are used for signalling in E1 interface.
Currently not in use. Must be '0'."
::= { atmCbrCnfgEntry 9 }
atmCbrCnfgRxBytesPerCell OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"number of bytes to be receive in order per cell to low the delay. "
DEFVAL { 47 }
::= { atmCbrCnfgEntry 10 }
atmCbrCnfgTxTimeSlots OBJECT-TYPE
SYNTAX TimeSlots
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This value indicates the time-slots used by this connection for receiving.
It uses 32 bits for E1 and low 24 bits for T1.
each bit represents a time slot for receiving :
time-slot 0 = bit 0 (LSB - most right bit in last byte),
...
...
time-slot 31 = bit 31 (MSB - most left bit in first byte ).
value '0' indicate unused time-slot and value '1' indicates used time-slot.
On set-request the user indicates the time-slot he needs for requested ATM-Vcc
by putting '1' to the right bits.
note : time-slots '0' and '16' are used for signalling in E1 interface.
Currently not in use. Must be '0'."
::= { atmCbrCnfgEntry 11 }
atmCbrCnfgTxBytesPerCell OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"number of bytes to be transmit in order per cell to low the delay. "
DEFVAL { 47 }
::= { atmCbrCnfgEntry 12 }
atmCbrCnfgParity OBJECT-TYPE
SYNTAX INTEGER
{
off (1),
on (2),
notApplicable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" Controls the use of pointer parity when using
the STRUCTURED or STRUCTURED WITH POINTER connection type.
as defined by atmCbrCnfgService.
ON - Pointer parity bit generation at the transmit side,
and checking of parity bit for error detection at
the receiving side enabled.
Supported only for STRUCTURED or STRUCTURED WITH POINTER service.
OFF - Pointer parity generation and checking disabled.
Supported only for STRUCTURED or STRUCTURED WITH POINTER service.
N/A - Not applicable. This is the only option
when selecting UNSTRUCTURED or STRUCTURED WITHOUT POINTER."
::= { atmCbrCnfgEntry 13 }
atmCbrCnfgRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or
modify or delete an existing row in this table."
::= { atmCbrCnfgEntry 14 }
atmCbrCnfgService OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
unstructured (2),
structured (3),
structuredWithPointer (4),
structuredWithoutPointer (5),
structuredControlSignalsTransport (6)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Define if DSx service is structured or unstructured.
A structured(3) interface is some nx64Kbps. (n x DS0 = n Time Slots)
An unstructured (2) interface is full DSx, x >0.
(1.544Mbps, 2.048Mbps, 6.312Mbps, 44.736 Mbps, or 34.368 Mbps.)
This objects selects the connection type also
for AAL1 Stream for Data port.
The available selections depend on the data rate
selected.
For the 64 kbps rate:
STRUCTURED WITH POINTER = structure(4)
Use of the structured service as defined in ATMF AF-VTOA-0078.000.
STRUCTURED WITHOUT POINTER : same as above, but without
using a pointer (the resulting cell structure is similar
to that of the unstructured service cells).
Default: STRUCTURED WITH POINTER
structuredControlSignalsTransport -Pointer is used to
transfer Data Control Signals through ATM network.
For other rates:
STRUCTURED : Use of structured service as defined in ATMF AF-VTOA-0078.000.
UNSTRUCTURED : Use of unstructured service as defined in
ATMF document AF-VTOA-0078.000."
::= { atmCbrCnfgEntry 15 }
-- *************************************************************
-- RAD ATM to CES ( Circuit-Emulation or DBCES data over DS1 )
-- Connections group
-- *************************************************************
atmCESConfExtnsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmCESConfExtnsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines virtual connections between ATM port and
DS1-CBR port."
::= { atmSuAtmCbr 2 }
atmCESConfExtnsEntry OBJECT-TYPE
SYNTAX AtmCESConfExtnsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry defines virtual connection between ATM port and
DS1-CBR port."
-- AUGMENTS { atmfCESConfEntry }
INDEX { atmfCESCbrIndex }
::= { atmCESConfExtnsTable 1 }
AtmCESConfExtnsEntry ::= SEQUENCE {
atmCESLastChange
TimeStamp,
atmCESRxBytesPerCell
Integer32,
atmCESTxBytesPerCell
Integer32,
atmCESAal1Type
INTEGER,
atmCESParity
INTEGER,
atmCESSigType
INTEGER,
atmCESSigABBits
OCTET STRING,
atmCESConnectionName
SnmpAdminString,
atmCESTcPattern
Integer32
}
atmCESLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time the ATM to CBR
connection entered its mandatory operational state.
If the mandatory state was entered prior to the last
re-initialization of the local network management
subsystem, then this object contains a zero value."
::= { atmCESConfExtnsEntry 1 }
atmCESRxBytesPerCell OBJECT-TYPE
SYNTAX Integer32 (1..47)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of bytes to be received per cell, in order to decrease the delay. "
DEFVAL { 47 }
::= { atmCESConfExtnsEntry 2 }
atmCESTxBytesPerCell OBJECT-TYPE
SYNTAX Integer32 (1..47)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of bytes to be transmitted per cell, in order to decrease the delay. "
DEFVAL { 47 }
::= { atmCESConfExtnsEntry 3 }
atmCESAal1Type OBJECT-TYPE
SYNTAX INTEGER {
ces(1),
dbces(2),
transparent(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Type of CBR connection: CES , DBCES or transparent ."
::= { atmCESConfExtnsEntry 4 }
atmCESParity OBJECT-TYPE
SYNTAX INTEGER
{
off (1),
on (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Indicate if we'll add even parity to the pointer of the structure of CES."
::= { atmCESConfExtnsEntry 5 }
atmCESSigType OBJECT-TYPE
SYNTAX INTEGER
{
eAndmOrPlar (1),
fxoLoopStart (2),
fxsLoopStart (3),
fxoGroundStart (4),
fxsGroundStart (5),
r2 (6),
other (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"type of signalling for a DBCES connection.
Must be 'other' for CES connection."
::= { atmCESConfExtnsEntry 6 }
atmCESSigABBits OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is applicable only when value of atmCESSigType is other.
Represents the AB bits for Rx/Tx and their masks in this way:
bits 7..6: Tx AB bits value,
bits 5..4: Tx AB bits mask,
bits 3..2: Rx AB bits value,
bits 1..0: Rx AB bits mask.
All bits must be 0 for CES connection."
::= { atmCESConfExtnsEntry 7 }
atmCESConnectionName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Connection's name."
::= { atmCESConfExtnsEntry 8 }
atmCESTcPattern OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trunk conditioning data pattern to be sent upon a DS0 fail.
Range is 0x0..0xFF."
::= { atmCESConfExtnsEntry 9 }
-- *************************************************************
-- RAD ATM to ETHERNET endpoints Connections group
-- *************************************************************
atmSuCrossConnectAtmEther OBJECT IDENTIFIER ::= { atmSuCrossConnect 4 }
atmSuCrossConnectAtmEtherIndexNext OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an appropriate value to
be used for atmEtherCnfgCrossConnectIndex when creating
entries in the atmEtherCnfgTable. The value
0 indicates that no unassigned entries are
available. To obtain the atmEtherCnfgCrossConnectIndex
value for a new entry, the manager issues a
management protocol retrieval operation to obtain
the current value of this object. After each
retrieval, the agent should modify the value to
the next unassigned index."
::= { atmSuCrossConnectAtmEther 1 }
atmEtherCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmEtherCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines virtual connections between ATM and
ATM-BridgedEthernet endpoints."
::= { atmSuCrossConnectAtmEther 2 }
atmEtherCnfgEntry OBJECT-TYPE
SYNTAX AtmEtherCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry defines virtual connection between ATM and
ATM-Ethernet endpoint."
INDEX {
atmEtherCnfgCrossConnectIndex,
atmEtherCnfgAtmIfIndex,
atmEtherCnfgAtmVpi,
atmEtherCnfgAtmVci,
atmEtherCnfgEtherIfIndex
}
::= { atmEtherCnfgTable 1 }
AtmEtherCnfgEntry ::= SEQUENCE {
atmEtherCnfgCrossConnectIndex
Integer32,
atmEtherCnfgAtmIfIndex
Integer32,
atmEtherCnfgAtmVpi
Integer32,
atmEtherCnfgAtmVci
Integer32,
atmEtherCnfgEtherIfIndex
Integer32,
atmEtherCnfgMacAddr
MacAddress,
atmEtherCnfgAdminStatus
INTEGER,
atmEtherCnfgOperStatus
INTEGER,
atmEtherCnfgLastChange
TimeStamp,
atmEtherCnfgTrafficDescrIndex
AtmTrafficDescrParamIndex,
atmEtherCnfgEncapsulationMode
INTEGER,
atmEtherCnfgPriority
INTEGER,
atmEtherCnfgRowStatus
RowStatus,
atmEtherCnfgRouterIP
IpAddress,
atmEtherCnfgRouterMask
IpAddress,
atmEtherCnfgRouterFragmentation
INTEGER,
atmEtherCnfgRouterRIPMode
INTEGER,
atmEtherCnfgRouterMTU
Integer32,
atmEtherCnfgPPPEncapsulation
INTEGER,
atmEtherCnfgAllocatedBuffers
Integer32,
atmEtherCnfgPauseTrigger
INTEGER
}
atmEtherCnfgCrossConnectIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value to identify this cross-connect."
::= { atmEtherCnfgEntry 1 }
atmEtherCnfgAtmIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex associated to the ATM interface."
::= { atmEtherCnfgEntry 2 }
atmEtherCnfgAtmVpi OBJECT-TYPE
SYNTAX Integer32 (1..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Vpi number of the ATM end point."
::= { atmEtherCnfgEntry 3 }
atmEtherCnfgAtmVci OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Vci number of the ATM end point."
::= { atmEtherCnfgEntry 4 }
atmEtherCnfgEtherIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex associated to the atm-Ethernet interface."
::= { atmEtherCnfgEntry 5 }
atmEtherCnfgMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The DFA number of the Ethernet end point."
::= { atmEtherCnfgEntry 6 }
atmEtherCnfgAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The requested state of the ATM to Ethernet connection."
::= { atmEtherCnfgEntry 7 }
atmEtherCnfgOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The real operational status of the ATM to Ethernet connection."
::= { atmEtherCnfgEntry 8 }
atmEtherCnfgLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time the ATM to Ethernet
connection entered its current operational state.
If the current state was entered prior to the last
re-initialization of the local network management
subsystem, then this object contains a zero value.
Same value define both direction ( Atm2Ether and Ether2Atm )."
::= { atmEtherCnfgEntry 9 }
atmEtherCnfgTrafficDescrIndex OBJECT-TYPE
SYNTAX AtmTrafficDescrParamIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies the row
in the atmTrafficDescrParamTable which
applies to the transmit direction of the VCL."
::= { atmEtherCnfgEntry 10 }
atmEtherCnfgEncapsulationMode OBJECT-TYPE
SYNTAX INTEGER
{
atmBridgedEther (1),
atmBridgedEtherCRC (2)
}
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"This object define the encapsulation type requested
for the connection.
it indicates if we transfer the Ethernet frame to the
atm side without the Crc32- AtmBridgedEther,
or with it - AtmBridgedEther_CRC. "
DEFVAL { atmBridgedEther }
::= { atmEtherCnfgEntry 11 }
atmEtherCnfgPriority OBJECT-TYPE
SYNTAX INTEGER
{
highPriority (1),
mediumPriority (2),
lowPriority (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object define the priority of connection.
The first parameter affects the transmition of cells in Conjested
network is the Service Category( Cbr has the highest priority and then Vbr,Ubr )
In connections with the same category this object will define the priority."
::= { atmEtherCnfgEntry 12 }
atmEtherCnfgRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or
modify or delete an existing row in this table."
::= { atmEtherCnfgEntry 13 }
atmEtherCnfgRouterIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The interface IP address for SNMP requests."
::= { atmEtherCnfgEntry 14 }
atmEtherCnfgRouterMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The interface IP address mask for SNMP requests."
::= { atmEtherCnfgEntry 15 }
atmEtherCnfgRouterFragmentation OBJECT-TYPE
SYNTAX INTEGER {
no (2),
yes (3),
notApplicable (255)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Fragmentation. When application is not router value must be 'notApplicable'."
::= { atmEtherCnfgEntry 16 }
atmEtherCnfgRouterRIPMode OBJECT-TYPE
SYNTAX INTEGER {
rip1 (1),
rip2 (2),
rip1And2 (3),
none (4),
notApplicable (255)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"RIP Mode. When application is not router value must be 'notApplicable'."
::= { atmEtherCnfgEntry 17 }
atmEtherCnfgRouterMTU OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
" ."
::= { atmEtherCnfgEntry 18 }
atmEtherCnfgPPPEncapsulation OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
rfc1483 (3), -- RFC1483 LLC Muxed
pppVcMuxed (4),
pppLlcMuxed (5),
rfc1483VcMuxed (6),
rfc1483BridgePdu (7) -- with LLC encapsulation
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object define the encapsulation type requested
for the connection.
rfc1483 - Multiprotocol Encapsulation over
ATM Adaptation Layer 5 (no PPP),
LLC Muxed.
PPP VC Muxed - For VC Based Multiplexing,
the carried network interconnect protocol is identified
implicitly by the VC connecting the two ATM stations,
i.e. each protocol must be carried over a separate VC.
There is therefore no need to include explicit multiplexing
information in the Payload of the AAL5 CPCS-PDU.
This results in minimal bandwidth and processing overhead.
PPP LLC Muxed - LLC (Low layer compatibility) Encapsulation
is needed when several protocols are carried over the same VC.
In order to allow the receiver to properly process the incoming
AAL5 CPCS-PDU, the Payload Field must contain information necessary
to identify the protocol of the routed or bridged PDU.
In LLC Encapsulation this informationis encoded in an LLC header
placed in front of the carried PDU."
DEFVAL { rfc1483 }
::= { atmEtherCnfgEntry 19 }
atmEtherCnfgAllocatedBuffers OBJECT-TYPE
SYNTAX Integer32 (10..217)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables user to limit the amount of buffers
used by the connection.
The limit set by this object will give
the effect of a virtual buffer pool per connection.
The user can allocate between 10 to 217 buffers
to every connection. By default the limit is 50 buffers.
Sum of limits allocated to all connections
must not exceed the total amount of available buffers.
Whenever a connection exceeds it's buffer limit
due to congestion or burst traffic is discarded"
DEFVAL { 50 }
::= { atmEtherCnfgEntry 20 }
atmEtherCnfgPauseTrigger OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/Disable LAN Pause triger from WAN connection"
::= { atmEtherCnfgEntry 21 }
-- *************************************************************
-- RAD ATM's index to User port's index Translation table
-- *************************************************************
atmSuCrossConnectTranslate OBJECT IDENTIFIER ::= { atmSuCrossConnect 5 }
atmTranslateTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmTranslateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table translates the three of AtmIfIndex,AtmVpi,AtmVci
to ifIndex of the interface on the user port's side."
::= { atmSuCrossConnectTranslate 1 }
atmTranslateEntry OBJECT-TYPE
SYNTAX AtmTranslateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry includes the User side interface's ifIndex of any virtual
connection along with the ATM connection indices."
INDEX { atmTranslateAtmIfIndex, atmTranslateAtmVpi, atmTranslateAtmVci }
::= { atmTranslateTable 1 }
AtmTranslateEntry ::= SEQUENCE {
atmTranslateAtmIfIndex
Integer32,
atmTranslateAtmVpi
Integer32,
atmTranslateAtmVci
Integer32,
atmTranslateUserIfIndex
Integer32
}
atmTranslateAtmIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex associated to the ATM interface."
::= { atmTranslateEntry 1 }
atmTranslateAtmVpi OBJECT-TYPE
SYNTAX Integer32 (1..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Vpi number of the ATM end point."
::= { atmTranslateEntry 2 }
atmTranslateAtmVci OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Vci number of the ATM end point."
::= { atmTranslateEntry 3 }
atmTranslateUserIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex associated to the user interface."
::= { atmTranslateEntry 4 }
-- *************************************************************
-- *************************************************************
-- Traps
-- *************************************************************
-- *************************************************************
--NOTIFICATIONS
radAtmEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for RAD ATM."
::= { radAtm 0 }
alarmTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent whenever an alarm
occurs in the agent."
::= { radAtmEvents 1 }
statusChangeTrap NOTIFICATION-TYPE
OBJECTS { agnLed, agnIndication }
STATUS current
DESCRIPTION
"This trap is sent whenever a led in the agent
change it's status."
::= { radAtmEvents 2 }
-- NO BUFFER TO NETWORK
atmSuAgnNoBufferToNetwork NOTIFICATION-TYPE
OBJECTS {alarmSeverity}
STATUS current
DESCRIPTION
"This trap usualy indicates timing problem;
incorrect selection of timing references
between end users."
::= { radAtmEvents 3 }
-- JITTER BUFFER OVERRUN
atmSuJitterBufferOverrun NOTIFICATION-TYPE
OBJECTS {alarmSeverity, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates that an overrun event
occurred in the ATM jitter buffer serving the
transmit to user direction of the
user interface specified by ifAlias"
::= { radAtmEvents 4 }
-- JITTER BUFFER UNDERRUN
atmSuJitterBufferUnderrun NOTIFICATION-TYPE
OBJECTS {alarmSeverity, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates that an underrun event
occurred in the atm jitter buffer serving the
transmit to user direction of the
user interface specified by ifAlias."
::= { radAtmEvents 5 }
-- DATA LOCAL LOOP
atmSuDataLocalLoopbackTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState,ifAlias}
STATUS current
DESCRIPTION
"This trap indicates that a local loopback
has been activated on the local data port."
::= { radAtmEvents 6 }
-- DATA REMOTE LOOP
atmSuDataRemoteLoopbackTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState,ifAlias}
STATUS current
DESCRIPTION
"This trap indicates that a remote loopback
has been activated on the local data port."
::= { radAtmEvents 7}
-- END
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\radsonet.txt
--
-- RAD-SONET-MIB DEFINITIONS ::= BEGIN
--Title: RAD-SONET MIB ver 545
--
-- IMPORTS
-- Gauge32 FROM RFC1155-SMI
-- ifIndex FROM RFC1213-MIB
-- OBJECT-TYPE FROM RFC-1212
-- radWan FROM RAD-GEN-MIB;
-- RAD-SONET MIB
--Title: RAD's SONET INTERFACE MIB
--Version: 1.0
--Date: 13.10.96
--By: Yair Arian
--File: radsonet.txt
--
--Last update: 5-Feb-2008 by Shay Harari
sonetInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 2}
prtSonetEvents OBJECT IDENTIFIER ::= {sonetInterface 0}
prtSonetPerfHistory OBJECT IDENTIFIER ::= {sonetInterface 1}
-- The SONET Medium Table
prtSonetMediumTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSonetMediumEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET Medium table."
::= { prtSonetPerfHistory 1 }
prtSonetMediumEntry OBJECT-TYPE
SYNTAX PrtSonetMediumEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET Medium table. ifIndex of the
lowest SONET layer of type sonet(39)."
INDEX { ifIndex }
::= { prtSonetMediumTable 1 }
PrtSonetMediumEntry ::=
SEQUENCE {
prtSonetMediumTimeElapsed
Integer32,
prtSonetMediumValidIntervals
Integer32,
prtSonetMediumSsmRX
OCTET STRING,
prtSonetMediumSsmTX
OCTET STRING
}
prtSonetMediumTimeElapsed OBJECT-TYPE
SYNTAX Integer32 (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since
the beginning of the near end current error-
measurement period."
::= { prtSonetMediumEntry 1 }
prtSonetMediumValidIntervals OBJECT-TYPE
SYNTAX Integer32 (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of previous near end intervals for
which valid data was collected. The value will be
96 unless the interface was brought online within
the last 24 hours, in which case the value will be
the number of complete 15 minute near end
intervals since the interface has been online."
::= { prtSonetMediumEntry 2 }
prtSonetMediumSsmRX OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates SSM RX value (quality level of clock signal).
SSM (Synchronization Status Messages) octet is encoded as follows:
Bit1 = '1' - indicates all octet is Not Applicable
Bits 8-5 (when bit1=0):
Left is MSB, where - MSB(8) ---> LSB(5)
8765
0000 Quality Unknown
0001 PRS (Stratum 1 Traceable)
0010 PRC (Primary Reference Clock) - Rec. G.811
0100 SSU-T (Sync. Source Unit-Transit)- Rec. G.812 Transit for SDH
TNC (Transit Node Clock Traceable) - for SONET
0111 ST2 (Stratum 2 Traceable)
1000 SSU-L (Sync. Source Unit Local) - Rec. G.812 Local
1010 ST3 (Stratum 3 Traceable)
1011 SEC (SDH Equipment Clock)
1100 SMC (SONET Minimum Clock Traceable)
1101 STS3E (Stratum 3E Traceable)
1111 DNU (do not use for synchronization) "
::= {prtSonetMediumEntry 3}
prtSonetMediumSsmTX OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates SSM TX value (quality level of clock signal).
SSM (Synchronization Status Messages) octet is encoded the same as
prtSonetMediumSsmRX."
::= {prtSonetMediumEntry 4}
-- The SONET Section/Line Current Table
-- The SONET Section/Line Current table contains various statistics being
-- collected for the current 15 minute interval.
prtSonetSectionLineCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSectionLineCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET Section/Line Current table."
::= { prtSonetPerfHistory 2 }
prtSectionLineCurrentEntry OBJECT-TYPE
SYNTAX PrtSectionLineCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET Section/Line Current table.
ifIndex of the section/line SONET layer of type
sonet(39)."
INDEX { ifIndex }
::= { prtSonetSectionLineCurrentTable 1 }
PrtSectionLineCurrentEntry ::=
SEQUENCE {
prtSonetCurrentLOS
Gauge32,
prtSonetCurrentLOF
Gauge32,
prtSonetCurrentLineAIS
Gauge32,
prtSonetCurrentLineFERF
Gauge32,
prtSonetCurrentSectionBIP
Gauge32,
prtSonetCurrentLineBIP
Gauge32,
prtSonetCurrentLineFEBE
Gauge32,
prtSonetCurrentUAS
Gauge32,
prtSonetCurrentSES
Gauge32,
prtSonetCurrentES
Gauge32,
prtSonetCurrentStatus
OCTET STRING,
prtSonetCurrentLSV
Gauge32,
prtSonetCurrentXStatus
Integer32,
prtSonetCurrentLineRDI
Gauge32
}
prtSonetCurrentLOS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOS
seconds, encountered by a SONET interface in
the current 15 minute interval."
::= { prtSectionLineCurrentEntry 1 }
prtSonetCurrentLOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOF
seconds, encountered by a SONET
interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 2 }
prtSonetCurrentLineAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line AIS
seconds, encountered by a SONET
interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 3 }
prtSonetCurrentLineFERF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line
FERF seconds, encountered by a SONET
interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 4 }
prtSonetCurrentSectionBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Section
BIP errors, encountered by a SONET
interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 5 }
prtSonetCurrentLineBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line
BIP errors, encountered by a SONET
interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 6 }
prtSonetCurrentLineFEBE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line
FEBE errors, encountered by a SONET
interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 7 }
prtSonetCurrentUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of UAS
encountered by a SONET
interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 8 }
prtSonetCurrentSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SES
encountered by a SONET
interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 9 }
prtSonetCurrentES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Errored Seconds, encountered by a
SONET interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 10 }
prtSonetCurrentStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statuses of the current interval:
0 - O.K.
1 - The link has been switched by a redundancy mechanism.
2 - Module is in/out.
4 - Empty - card is out."
::= { prtSectionLineCurrentEntry 11 }
prtSonetCurrentLSV OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LSV
seconds (Line Symbol Violation), encountered by a
SONET interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 12 }
prtSonetCurrentXStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the Status of the interface.
It contains failure state information.
The variable is a bit map represented as a sum, therefore, it
can represent multiple failures simultaneously.
The sonetSectionLineNoDefect must be set if and only if no other flag is set.
The various bit positions are:
1 sonetSectionLineNoDefect
2 sonetSectionLOS Loss Of Signal
4 sonetSectionLOF Loss Of Frame
8 sonetSectionLOC Loss Of Clock
16 sonetLineAIS Alarm Indication Signal
32 sonetLineRDI Remote Defect Indication
64 sonetLineRFI Remote Failure Indication (RDI lasts for 2.5 (+-0.5) seconds)
128 sonetLineEBER Excessive Bit Error Rate
256 sonetLineSD Signal Degradation
512 sonetOOF Out Of Frame."
::= { prtSectionLineCurrentEntry 13 }
prtSonetCurrentLineRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line RDI
seconds, encountered by a SONET
interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 14 }
-- The SONET Section/Line interface Interval
-- The SONET Section/Line Interval Table contains various statistics
-- collected by the Interface over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
prtSonetSectionLineIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSectionLineIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Section/Line Interval table."
::= { prtSonetPerfHistory 3 }
prtSectionLineIntervalEntry OBJECT-TYPE
SYNTAX PrtSectionLineIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET Section/Line Interval table.
ifIndex of the section/line SONET layer of type
sonet(39)."
INDEX { ifIndex, prtSonetLineIntervalNumber }
::= { prtSonetSectionLineIntervalTable 1 }
PrtSectionLineIntervalEntry ::=
SEQUENCE {
prtSonetLineIntervalNumber
Integer32,
prtSonetIntervalLOS
Gauge32,
prtSonetIntervalLOF
Gauge32,
prtSonetIntervalLineAIS
Gauge32,
prtSonetIntervalLineFERF
Gauge32,
prtSonetIntervalSectionBIP
Gauge32,
prtSonetIntervalLineBIP
Gauge32,
prtSonetIntervalLineFEBE
Gauge32,
prtSonetIntervalUAS
Gauge32,
prtSonetIntervalSES
Gauge32,
prtSonetIntervalES
Gauge32,
prtSonetIntervalStatus
OCTET STRING,
prtSonetIntervalLSV
Gauge32,
prtSonetIntervalLineRDI
Gauge32
}
prtSonetLineIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { prtSectionLineIntervalEntry 1 }
prtSonetIntervalLOS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOS
seconds , encountered by a SONET interface in
one of the previous 96, individual 15 minute,
intervals."
::= { prtSectionLineIntervalEntry 2 }
prtSonetIntervalLOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOF
seconds, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtSectionLineIntervalEntry 3 }
prtSonetIntervalLineAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line
AIS seconds, encountered by a SONET
interface in one of the previous 96,
individual 15 minute, intervals."
::= { prtSectionLineIntervalEntry 4 }
prtSonetIntervalLineFERF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line
FERF seconds, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtSectionLineIntervalEntry 5 }
prtSonetIntervalSectionBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Section
BIP errors, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtSectionLineIntervalEntry 6 }
prtSonetIntervalLineBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line
BIP errors, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtSectionLineIntervalEntry 7 }
prtSonetIntervalLineFEBE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line
FEBE errors, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtSectionLineIntervalEntry 8 }
prtSonetIntervalUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of UAS
encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtSectionLineIntervalEntry 9 }
prtSonetIntervalSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SES
encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtSectionLineIntervalEntry 10 }
prtSonetIntervalES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Errored Seconds, encountered by a
SONET interface in one of the previous 96, individual 15
minute, intervals."
::= { prtSectionLineIntervalEntry 11 }
prtSonetIntervalStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The statuses of the current interval:
0 - O.K.
1 - The link has been switched by a redundancy mechanism.
2 - Module is in/out.
4 - Empty - card is out."
::= { prtSectionLineIntervalEntry 12 }
prtSonetIntervalLSV OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LSV seconds
(Line Symbol Violation), encountered by a SONET interface
in one of the previous 96, individual 15 minute, intervals."
::= { prtSectionLineIntervalEntry 13 }
prtSonetIntervalLineRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line
RDI seconds, encountered by a SONET
interface in one of the previous 96,
individual 15 minute, intervals."
::= { prtSectionLineIntervalEntry 14 }
-- The SONET Path Current Table
-- The SONET Path Current table contains various statistics being
-- collected for the current 15 minute interval.
prtSonetPathCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtPathCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET Path Current table."
::= { prtSonetPerfHistory 4 }
prtPathCurrentEntry OBJECT-TYPE
SYNTAX PrtPathCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET Path Current table.
ifIndex of the Path SONET layer of type
sonetPath(50)."
INDEX { ifIndex }
::= { prtSonetPathCurrentTable 1 }
PrtPathCurrentEntry ::=
SEQUENCE {
prtSonetCurrentPathAIS
Gauge32,
prtSonetCurrentPathFERF
Gauge32,
prtSonetCurrentLOP
Gauge32,
prtSonetCurrentSLM
Gauge32,
prtSonetCurrentLOC
Gauge32,
prtSonetCurrentPathBIP
Gauge32,
prtSonetCurrentPathFEBE
Gauge32,
prtSonetPathCurrentStatus
Integer32,
prtSonetCurrentPathRDI
Gauge32
}
prtSonetCurrentPathAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Path AIS
seconds, encountered by a SONET interface in
the current 15 minute interval."
::= { prtPathCurrentEntry 1 }
prtSonetCurrentPathFERF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Path FERF
seconds, encountered by a SONET
interface in the current 15 minute interval."
::= { prtPathCurrentEntry 2 }
prtSonetCurrentLOP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number LOP
seconds, encountered by a SONET
interface in the current 15 minute interval."
::= { prtPathCurrentEntry 3 }
prtSonetCurrentSLM OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SLM
seconds, encountered by a SONET
interface in the current 15 minute interval."
::= { prtPathCurrentEntry 4 }
prtSonetCurrentLOC OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOC
seconds, encountered by a SONET
interface in the current 15 minute interval."
::= { prtPathCurrentEntry 5 }
prtSonetCurrentPathBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Path
BIP errors, encountered by a SONET
interface in the current 15 minute interval."
::= { prtPathCurrentEntry 6 }
prtSonetCurrentPathFEBE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Path
FEBE errors, encountered by a SONET
interface in the current 15 minute interval."
::= { prtPathCurrentEntry 7 }
prtSonetPathCurrentStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the Status of the interface.
It contains failure state information.
The variable is a bit map represented as a sum, therefore, it
can represent multiple failures simultaneously.
The sonetPathNoDefect must be set if and only if no other flag is set.
The various bit positions are:
1 sonetPathNoDefect
2 sonetPathSTSLOP Loss Of Pointer
4 sonetPathSTSAIS Alarm Indication Signal
8 sonetPathSTSRDI Remote Defect Indication
16 sonetPathUnequipped Signal Label Unequipped
32 sonetPathSignalLabelMismatch Signal Label Mismatch
64 sonetPathRFI Remote Failure Indication
(RDI lasts for 2.5 (+-0.5) seconds)
128 sonetPathEBER Excessive Bit Error Rate
256 sonetPathSD Signal Degradation
512 sonetPathLOM Loss Of Multiframe."
::= { prtPathCurrentEntry 8 }
prtSonetCurrentPathRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Path RDI
seconds, encountered by a SONET interface in
the current 15 minute interval."
::= { prtPathCurrentEntry 9 }
-- The SONET Path interface Interval
-- The SONET Path Interval Table contains various statistics
-- collected by the Interface over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
prtSonetPathIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtPathIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Path Interval table."
::= { prtSonetPerfHistory 5 }
prtPathIntervalEntry OBJECT-TYPE
SYNTAX PrtPathIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET Path Interval table."
INDEX { ifIndex, prtSonetPathIntervalNumber }
::= { prtSonetPathIntervalTable 1 }
PrtPathIntervalEntry ::=
SEQUENCE {
prtSonetPathIntervalNumber
Integer32,
prtSonetIntervalPathAIS
Gauge32,
prtSonetIntervalPathFERF
Gauge32,
prtSonetIntervalLOP
Gauge32,
prtSonetIntervalSLM
Gauge32,
prtSonetIntervalLOC
Gauge32,
prtSonetIntervalPathBIP
Gauge32,
prtSonetIntervalPathFEBE
Gauge32,
prtSonetIntervalPathRDI
Gauge32
}
prtSonetPathIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { prtPathIntervalEntry 1 }
prtSonetIntervalPathAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Path
AIS seconds , encountered by a SONET interface in
one of the previous 96, individual 15 minute,
intervals."
::= { prtPathIntervalEntry 2 }
prtSonetIntervalPathFERF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Path
FERF seconds, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtPathIntervalEntry 3 }
prtSonetIntervalLOP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOP
seconds, encountered by a SONET
interface in one of the previous 96,
individual 15 minute, intervals."
::= { prtPathIntervalEntry 4 }
prtSonetIntervalSLM OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SLM
seconds, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtPathIntervalEntry 5 }
prtSonetIntervalLOC OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOC
seconds, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtPathIntervalEntry 6 }
prtSonetIntervalPathBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Path
BIP errors, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtPathIntervalEntry 7 }
prtSonetIntervalPathFEBE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Path
FEBE errors, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtPathIntervalEntry 8 }
prtSonetIntervalPathRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Path
RDI seconds , encountered by a SONET interface in
one of the previous 96, individual 15 minute,
intervals."
::= { prtPathIntervalEntry 9 }
virtualIfStatistics OBJECT IDENTIFIER ::= { prtSonetPerfHistory 6}
-- the Virtual Interface Current Table
virtualIfCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF VirtualIfCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Interface Current table."
::= { virtualIfStatistics 1 }
virtualIfCurrentEntry OBJECT-TYPE
SYNTAX VirtualIfCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Interface Current table."
INDEX { ifIndex }
::= { virtualIfCurrentTable 1 }
VirtualIfCurrentEntry ::=
SEQUENCE {
virtualIfCurrentMinActiveVC Integer32,
virtualIfCurrentMaxActiveVC Integer32,
virtualIfCurrentRxFrames Counter64,
virtualIfCurrentTxFrames Counter64,
virtualIfCurrentRxAbortFrames PerfCurrentCount,
virtualIfCurrentTxAbortFrames PerfCurrentCount,
virtualIfCurrentMinLengthViolation PerfCurrentCount,
virtualIfCurrentMaxLengthViolation PerfCurrentCount,
virtualIfCurrentFcsError PerfCurrentCount,
virtualIfCurrentByteDestuffingViolation PerfCurrentCount,
virtualIfCurrentAdressMismatch PerfCurrentCount,
virtualIfCurrentControlMismatch PerfCurrentCount,
virtualIfCurrentActiveVC Integer32
}
virtualIfCurrentMinActiveVC OBJECT-TYPE
SYNTAX Integer32 (1..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the minimum number of active virtual containers (VCs)
of the Virtual Concatenation Group in the current 15-minute interval."
::= { virtualIfCurrentEntry 1 }
virtualIfCurrentMaxActiveVC OBJECT-TYPE
SYNTAX Integer32 (1..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the maximum number of active virtual containers (VCs)
of the Virtual Concatenation Group in the current 15-minute interval."
::= {virtualIfCurrentEntry 2 }
virtualIfCurrentRxFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of frames received from STS-3/STM-1
by a Virtual Interface in the current 15-minute interval."
::= { virtualIfCurrentEntry 3}
virtualIfCurrentTxFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of frames transmitted to STS-3/STM-1
by a Virtual Interface in the current 15-minute interval."
::= { virtualIfCurrentEntry 4 }
virtualIfCurrentRxAbortFrames OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Received Aborted frames
encountered by a Virtual Interface in the current 15-minute interval."
::= { virtualIfCurrentEntry 5 }
virtualIfCurrentTxAbortFrames OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Transmitted Aborted frames
encountered by a Virtual Interface in the current 15-minute interval."
::= { virtualIfCurrentEntry 6 }
virtualIfCurrentMinLengthViolation OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Rx payload Min Length Violation frames encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfCurrentEntry 7 }
virtualIfCurrentMaxLengthViolation OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Rx payload Max Length Violation frames
encountered by a Virtual Interface in the current 15-minute interval."
::= { virtualIfCurrentEntry 8 }
virtualIfCurrentFcsError OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter is associated with the number of
Frame Check Sequence errors encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfCurrentEntry 9 }
virtualIfCurrentByteDestuffingViolation OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Byte De-stuffing Violations encountered by a Virtual Interface
in the current 15-minute interval."
::= {virtualIfCurrentEntry 10 }
virtualIfCurrentAdressMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Adress Mismatch encountered by a Virtual Interface
in the current 15-minute interval."
::= {virtualIfCurrentEntry 11 }
virtualIfCurrentControlMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Control Mismatch encountered by a Virtual Interface
in the current 15-minute interval."
::= {virtualIfCurrentEntry 12 }
virtualIfCurrentActiveVC OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the number of active virtual containers (VCs)
of the Virtual Concatenation Group in the current 15-minute interval."
::= {virtualIfCurrentEntry 13 }
-- the Virtual Interface Interval Table
-- The Virtual Interface Interval Table
-- contains various statistics collected over a maximum
-- of the previous 24 hours of operation.
-- The past 24 hours may be broken into 96
-- completed 15 minute intervals.
virtualIfIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF VirtualIfIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Interface Interval table."
::= { virtualIfStatistics 2 }
virtualIfIntervalEntry OBJECT-TYPE
SYNTAX VirtualIfIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Interface Interval table."
INDEX { ifIndex, virtualIfIntervalNumber }
::= { virtualIfIntervalTable 1 }
VirtualIfIntervalEntry ::=
SEQUENCE {
virtualIfIntervalNumber Integer32,
virtualIfIntervalMinActiveVC Integer32,
virtualIfIntervalMaxActiveVC Integer32,
virtualIfIntervalRxFrames Counter64,
virtualIfIntervalTxFrames Counter64,
virtualIfIntervalRxAbortFrames PerfIntervalCount,
virtualIfIntervalTxAbortFrames PerfIntervalCount,
virtualIfIntervalMinLengthViolation PerfIntervalCount,
virtualIfIntervalMaxLengthViolation PerfIntervalCount,
virtualIfIntervalFcsError PerfIntervalCount,
virtualIfIntervalByteDestuffingViolation PerfIntervalCount,
virtualIfIntervalAdressMismatch PerfIntervalCount,
virtualIfIntervalControlMismatch PerfIntervalCount,
virtualIfIntervalBelowMinThreshold PerfIntervalCount
}
virtualIfIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified by N-1."
::= { virtualIfIntervalEntry 1 }
virtualIfIntervalMinActiveVC OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the minimum number of
active virtual containers (VCs) of the Virtual Concatenation Group, in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 2 }
virtualIfIntervalMaxActiveVC OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the maximum number of
active virtual containers (VCs) of the Virtual Concatenation Group, in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 3 }
virtualIfIntervalRxFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
frames received from STS-3/STM-1 by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 4 }
virtualIfIntervalTxFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
frames transmitted to STS-3/STM-1 by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 5 }
virtualIfIntervalRxAbortFrames OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Received Abort frames encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= {virtualIfIntervalEntry 6 }
virtualIfIntervalTxAbortFrames OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Transmitted Abort frames encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 7 }
virtualIfIntervalMinLengthViolation OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Rx payload Min Length Violation frames
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 8 }
virtualIfIntervalMaxLengthViolation OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Rx payload Max Length Violation frames
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 9 }
virtualIfIntervalFcsError OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Frame Check Sequence errors encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 10 }
virtualIfIntervalByteDestuffingViolation OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Byte De-stuffing Violations
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 11 }
virtualIfIntervalAdressMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Address Mismatch encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 12 }
virtualIfIntervalControlMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Control mismatch encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 13 }
virtualIfIntervalBelowMinThreshold OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
seconds that number of active VCs was below minimum threshold
defined by vcGroupCnfgNoOfVCs,
encountered by Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 14 }
-- the Virtual Interface LAPS Current Table
virtualIfLAPSCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF VcGroupLAPSCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Interface LAPS Current table."
::= { virtualIfStatistics 3 }
virtualIfLAPSCurrentEntry OBJECT-TYPE
SYNTAX VcGroupLAPSCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Interface
LAPS Current table."
INDEX { ifIndex }
::= { virtualIfLAPSCurrentTable 1 }
VcGroupLAPSCurrentEntry ::=
SEQUENCE {
virtualIfLAPSCurrentSapiMismatch PerfCurrentCount
}
virtualIfLAPSCurrentSapiMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received SAPI field mismatch
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfLAPSCurrentEntry 1 }
-- the Virtual Interface LAPS Interval Table
-- The Virtual Interface LAPS Interval Table
-- contains various statistics collected over a maximum
-- of the previous 24 hours of operation.
-- The past 24 hours may be broken into 96
-- completed 15 minute intervals.
virtualIfLAPSIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF VirtualIfLAPSIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Interface LAPS table."
::= { virtualIfStatistics 4 }
virtualIfLAPSIntervalEntry OBJECT-TYPE
SYNTAX VirtualIfLAPSIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Interface
LAPS Interval table."
INDEX { ifIndex, virtualIfIntervalNumber }
::= { virtualIfLAPSIntervalTable 1 }
VirtualIfLAPSIntervalEntry ::=
SEQUENCE {
virtualIfLAPSIntervalSapiMismatch PerfIntervalCount
}
virtualIfLAPSIntervalSapiMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received SAPI field mismatch
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfLAPSIntervalEntry 1 }
-- the Virtual Interface LAPF Current Table
virtualIfLAPFCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF VirtualIfLAPFCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Interface LAPF Current table."
::= { virtualIfStatistics 5 }
virtualIfLAPFCurrentEntry OBJECT-TYPE
SYNTAX VirtualIfLAPFCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Interface
LAPF Current table."
INDEX { ifIndex }
::= { virtualIfLAPFCurrentTable 1 }
VirtualIfLAPFCurrentEntry ::=
SEQUENCE {
virtualIfLAPFCurrentNlpidMismatch PerfCurrentCount,
virtualIfLAPFCurrentOuiMismatch PerfCurrentCount,
virtualIfLAPFCurrentPidMismatch PerfCurrentCount,
virtualIfLAPFCurrentDlciMismatch PerfCurrentCount,
virtualIfLAPFCurrentMacRxFrames PerfCurrentCount,
virtualIfLAPFCurrentMacTxFrames PerfCurrentCount
}
virtualIfLAPFCurrentNlpidMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received NLPID field mismatch
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfLAPFCurrentEntry 1 }
virtualIfLAPFCurrentOuiMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received OUI field mismatch
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfLAPFCurrentEntry 2 }
virtualIfLAPFCurrentPidMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received PID field mismatch
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfLAPFCurrentEntry 3 }
virtualIfLAPFCurrentDlciMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received DLCI field mismatch
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfLAPFCurrentEntry 4 }
virtualIfLAPFCurrentMacRxFrames OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
frames received from LAN
by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfLAPFCurrentEntry 5 }
virtualIfLAPFCurrentMacTxFrames OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
frames transmitted to LAN
by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfLAPFCurrentEntry 6 }
-- the Virtual Interface LAPF Interval Table
-- The Virtual Interface LAPF Interval Table
-- contains various statistics collected over a maximum
-- of the previous 24 hours of operation.
-- The past 24 hours may be broken into 96
-- completed 15 minute intervals.
virtualIfLAPFIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF VirtualIfLAPFIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Interface LAPF Interval table."
::= { virtualIfStatistics 6 }
virtualIfLAPFIntervalEntry OBJECT-TYPE
SYNTAX VirtualIfLAPFIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Interface Interval table."
INDEX { ifIndex, virtualIfIntervalNumber }
::= { virtualIfLAPFIntervalTable 1 }
VirtualIfLAPFIntervalEntry ::=
SEQUENCE {
virtualIfLAPFIntervalNlpidMismatch PerfIntervalCount,
virtualIfLAPFIntervalOuiMismatch PerfIntervalCount,
virtualIfLAPFIntervalPidMismatch PerfIntervalCount,
virtualIfLAPFIntervalDlciMismatch PerfIntervalCount,
virtualIfLAPFIntervalMacRxFrames PerfIntervalCount,
virtualIfLAPFIntervalMacTxFrames PerfIntervalCount
}
virtualIfLAPFIntervalNlpidMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received NLPID field mismatch
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfLAPFIntervalEntry 1 }
virtualIfLAPFIntervalOuiMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received OUI field mismatch
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfLAPFIntervalEntry 2 }
virtualIfLAPFIntervalPidMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received PID field mismatch
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfLAPFIntervalEntry 3 }
virtualIfLAPFIntervalDlciMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received DLCI field mismatch
by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfLAPFIntervalEntry 4 }
virtualIfLAPFIntervalMacRxFrames OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
frames received from LAN
by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfLAPFIntervalEntry 5 }
virtualIfLAPFIntervalMacTxFrames OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
frames transmitted to LAN
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfLAPFIntervalEntry 6 }
-- the Virtual Interface GFP Current Table
virtualIfGFPCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF VirtualIfGFPCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Interface GFP Current table."
::= { virtualIfStatistics 7 }
virtualIfGFPCurrentEntry OBJECT-TYPE
SYNTAX VirtualIfGFPCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Interface
GFP Current table."
INDEX { ifIndex }
::= { virtualIfGFPCurrentTable 1 }
VirtualIfGFPCurrentEntry ::=
SEQUENCE {
virtualIfGFPCurrentIdleFrameError PerfCurrentCount,
virtualIfGFPCurrentCHecSbError PerfCurrentCount,
virtualIfGFPCurrentPtiMismatch PerfCurrentCount,
virtualIfGFPCurrentExiMismatch PerfCurrentCount,
virtualIfGFPCurrentUpiMismatch PerfCurrentCount,
virtualIfGFPCurrentTHecSbError PerfCurrentCount,
virtualIfGFPCurrentTHecMbError PerfCurrentCount,
virtualIfGFPCurrentCidMismatch PerfCurrentCount,
virtualIfGFPCurrentEHecSbError PerfCurrentCount,
virtualIfGFPCurrentEHecMbError PerfCurrentCount
}
virtualIfGFPCurrentIdleFrameError OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP IDLE frames that are
detected to be in error,
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 1}
virtualIfGFPCurrentCHecSbError OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected to have
single-bit errors in the Core
header (i.e. cHEC field) only,
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 2 }
virtualIfGFPCurrentPtiMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
rreceived GFP frames that are detected with
a mismatch on the PTI field
(i.e. value of PTI is not equal to
Client Data or Management frame),
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 3 }
virtualIfGFPCurrentExiMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected with
a mismatch on the EXI field
(i.e. value of EXI is not equal
to NULL or LINEAR modes),
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 4 }
virtualIfGFPCurrentUpiMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected with a
mismatch on the UPI field
(i.e. value of EXI is not equal to 00000001),
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 5 }
virtualIfGFPCurrentTHecSbError OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected
to only have single-bit errors in the Type header
(i.e. tHEC field),
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 6 }
virtualIfGFPCurrentTHecMbError OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected to
only have multi-bit errors in the
Type header (i.e. tHEC field),
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 7 }
virtualIfGFPCurrentCidMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected to have a
mismatch/unsupported value in the CID field only,
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 8 }
virtualIfGFPCurrentEHecSbError OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected
to only have single-bit errors
in the Extension header (i.e. eHEC field),
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 9 }
virtualIfGFPCurrentEHecMbError OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected to only
have single-bit errors in the
Extension header (i.e. eHEC field),
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 10 }
-- the Virtual Interface GFP Interval Table
-- The Virtual Interface GFP Interval Table
-- contains various statistics collected over a maximum
-- of the previous 24 hours of operation.
-- The past 24 hours may be broken into 96
-- completed 15 minute intervals.
virtualIfGFPIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF VirtualIfGFPIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Interface GFP Interval table."
::= { virtualIfStatistics 8 }
virtualIfGFPIntervalEntry OBJECT-TYPE
SYNTAX VirtualIfGFPIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Interface
GFP Interval table."
INDEX { ifIndex, virtualIfIntervalNumber }
::= { virtualIfGFPIntervalTable 1 }
VirtualIfGFPIntervalEntry ::=
SEQUENCE {
virtualIfGFPIntervalIdleFrameError PerfIntervalCount,
virtualIfGFPIntervalCHecSbError PerfIntervalCount,
virtualIfGFPIntervalPtiMismatch PerfIntervalCount,
virtualIfGFPIntervalExiMismatch PerfIntervalCount,
virtualIfGFPIntervalUpiMismatch PerfIntervalCount,
virtualIfGFPIntervalTHecSbError PerfIntervalCount,
virtualIfGFPIntervalTHecMbError PerfIntervalCount,
virtualIfGFPIntervalCidMismatch PerfIntervalCount,
virtualIfGFPIntervalEHecSbError PerfIntervalCount,
virtualIfGFPIntervalEHecMbError PerfIntervalCount
}
virtualIfGFPIntervalIdleFrameError OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP IDLE frames that are detected to be in error,
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 1 }
virtualIfGFPIntervalCHecSbError OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected to have
single-bit errors in the Core header (i.e. cHEC field) only,
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 2 }
virtualIfGFPIntervalPtiMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
rreceived GFP frames that are detected with
a mismatch on the PTI field (i.e. value of PTI
is not equal to Client Data or Management frame),
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 3 }
virtualIfGFPIntervalExiMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected with
a mismatch on the EXI field (i.e. value of EXI is not
equal to NULL or LINEAR modes),
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 4 }
virtualIfGFPIntervalUpiMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected with a
mismatch on the UPI field (i.e. value of EXI
is not equal to 00000001),
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 5 }
virtualIfGFPIntervalTHecSbError OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected to only have
single-bit errors in the Type header (i.e. tHEC field),
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 6 }
virtualIfGFPIntervalTHecMbError OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated withthe number of
received GFP frames that are detected to only have
multi-bit errors in the Type header (i.e. tHEC field),
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 7 }
virtualIfGFPIntervalCidMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected to have a
mismatch/unsupported value in the CID field only,
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 8 }
virtualIfGFPIntervalEHecSbError OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected
to only have single-bit errors
in the Extension header (i.e. eHEC field),
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 9 }
virtualIfGFPIntervalEHecMbError OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the the number of
received GFP frames that are detected to only have
multi-bit errors in the Extension header (i.e. eHEC field),
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 10 }
prtSonetConfig OBJECT IDENTIFIER ::= {sonetInterface 2}
prtSonetGen OBJECT IDENTIFIER ::= {prtSonetConfig 1}
prtSonetGenTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSonetGenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Sonet/SDH general port configuration table."
::= { prtSonetGen 1}
prtSonetGenEntry OBJECT-TYPE
SYNTAX PrtSonetGenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry in the Sonet/SDH general port configuration table."
INDEX { prtSonetGenCnfgIdx, prtSonetGenIdx }
::= { prtSonetGenTable 1}
PrtSonetGenEntry ::=
SEQUENCE {
prtSonetGenCnfgIdx
Integer32,
prtSonetGenIdx
Integer32,
prtSonetGenSdThreshold
INTEGER,
prtSonetGenEedThreshold
INTEGER,
prtSonetGenBerEnable
INTEGER
}
prtSonetGenCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
For products that support several configurations, Set can be performed
only to the Temporary Config (=255). "
::= { prtSonetGenEntry 1}
prtSonetGenIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique port or interface number.
For numbering, see product's spec.
For some products, the numbering can equal ifIndex."
::= { prtSonetGenEntry 2}
prtSonetGenSdThreshold OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
n3 (3),
n4 (4),
n5 (5),
n6 (6),
n7 (7),
n8 (8),
n9 (9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SD=Signal Degraded Threshold. Units: [10E-].
The threshold is 10E-x relative to the frequency of the data flow.
x=3, 4, 5, 6, 7, 8, 9.
n3= 10E-3
n4= 10E-4
n5= 10E-5
n6= 10E-6
n7= 10E-7
n8= 10E-8
n9= 10E-9 ."
::= { prtSonetGenEntry 3 }
prtSonetGenEedThreshold OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
n3 (3),
n4 (4),
n5 (5),
n6 (6),
n7 (7),
n8 (8),
n9 (9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"EED=Excessive Error Defect Threshold. Units: [10E-].
The threshold is 10E-x relative to the frequency of the data flow.
x=3, 4, 5, 6, 7, 8, 9.
n3= 10E-3
n4= 10E-4
n5= 10E-5
n6= 10E-6
n7= 10E-7
n8= 10E-8
n9= 10E-9 ."
::= { prtSonetGenEntry 4 }
prtSonetGenBerEnable OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls the activation of the Line Ber (Bit Error Rate), means whether
SD and EED threshold parameters will be enabled."
::= { prtSonetGenEntry 5 }
--STM-1 ports
prtSonetStm1 OBJECT IDENTIFIER ::= {prtSonetConfig 2}
prtSonetStm1Table OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSonetStm1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Sonet/SDH STM-1 port configuration table."
::= { prtSonetStm1 1}
prtSonetStm1Entry OBJECT-TYPE
SYNTAX PrtSonetStm1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry in the Sonet/SDH STM-1 port configuration table."
INDEX { prtSonetStm1CnfgIdx, prtSonetStm1Idx }
::= { prtSonetStm1Table 1}
PrtSonetStm1Entry ::=
SEQUENCE {
prtSonetStm1CnfgIdx
Integer32,
prtSonetStm1Idx
Integer32,
prtSonetStm1ClockSrc
INTEGER,
prtSonetStm1DccMode
INTEGER,
prtSonetStm1RoutingProt
INTEGER,
prtSonetStm1MngProt
INTEGER,
prtSonetStm1OperationalMode
INTEGER,
prtSonetStm1VoiceChannel
INTEGER,
prtSonetStm1OutputRate
Integer32,
prtSonetStm1S1ProtocolClock
INTEGER,
prtSonetStm1GatewayRingSubnetAddress
IpAddress,
prtSonetStm1GatewayRingSubnetMask
IpAddress,
prtSonetStm1MngProtDeviationType
INTEGER,
prtSonetStm1MngSameIpAsHost
INTEGER,
prtSonetStm1MngIpAddress
IpAddress,
prtSonetStm1MngIpSubnetMask
IpAddress,
prtSonetStm1MngDefaultGateway
IpAddress
}
prtSonetStm1CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
For products that support several configurations, Set can be performed
only to the Temporary Config (=255). "
::= { prtSonetStm1Entry 1}
prtSonetStm1Idx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique port or interface number.
For numbering, see product's spec.
For some products, the numbering can equal ifIndex."
::= { prtSonetStm1Entry 2}
prtSonetStm1ClockSrc OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
internal (2),
lbt (3),
systemClk (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock Source of the STM-1 port.
lbt = Loop Back Timing."
::= { prtSonetStm1Entry 3 }
prtSonetStm1DccMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
none (2),
d1ToD3 (3),
d4ToD12 (4),
d1 (5),
d2 (6),
d3 (7),
d4 (8),
d5 (9),
d6 (10),
d7 (11),
d8 (12),
d9 (13),
d10 (14),
d11 (15),
d12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DCC Mode. DCC=Data Communication Channel.
d1ToD3 = D1-D3 bytes are used (RS=Regeneration Section).
d4ToD12= D4-D12 bytes are used (MS=Multiplexing Section).
d1.... d12 enable user to select single DCC byte "
::= { prtSonetStm1Entry 4 }
prtSonetStm1RoutingProt OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
none (2),
proprietary (3),
rip2 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Routing Protocol."
::= { prtSonetStm1Entry 5 }
prtSonetStm1MngProt OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
-- none (2)
proprietary (3),
-- rip2 (4)
ppp (5),
frameRelay (6),
hdlc (7),
lapdOverHdlc (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Management Protocol over DCC: Proprietary, PPP, Frame Relay,
HDLC or LAPD over HDLC .
ppp = according to STD-51 ( rfc1661/1662)"
::= { prtSonetStm1Entry 6 }
prtSonetStm1OperationalMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
terminal (2),
linear (3),
linearProtection (4),
dualRing (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Operational Mode.
linear - cannot be selected when there is Redundancy between the
STM-1 ports."
::= { prtSonetStm1Entry 7 }
prtSonetStm1VoiceChannel OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
none (2),
e1Byte (3),
e2Byte (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter enable user to select whether
voice channel will be transferred using E1 byte, E2 Byte, or not at all."
::= { prtSonetStm1Entry 8 }
prtSonetStm1OutputRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the output rate in cells/sec, which is
supported per port."
::= { prtSonetStm1Entry 9 }
prtSonetStm1S1ProtocolClock OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
disable (2),
enable (3),
transparent (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter allows user to select whether to enable use of
Remote Side Clock according to the Protocol passed on S1 Bit."
::= { prtSonetStm1Entry 10 }
prtSonetStm1GatewayRingSubnetAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines subnet for static routing,
together with prtSonetStm1GatewayRingSubnetMask"
::= { prtSonetStm1Entry 11 }
prtSonetStm1GatewayRingSubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines subnet for static routing,
together with prtSonetStm1GatewayRingSubnetAddress"
::= { prtSonetStm1Entry 12 }
prtSonetStm1MngProtDeviationType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
standard (2),
type1 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is used in conjunction with prtSonetStm1MngProt
to define management protocol used & type of deviation
(if exist) from standard.
Standard = no deviation from standard protocol
Type1 = PPP without sending Address and Control overhead
in Link Control Protocol (LCP) packets"
::= { prtSonetStm1Entry 13 }
prtSonetStm1MngSameIpAsHost OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates whether IP address
used for management is same as the device IP address"
::= { prtSonetStm1Entry 14 }
prtSonetStm1MngIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines IP address for DCC management
for this link, together with prtSonetStm1MngIpSubnetMask.
This parameter is applicable only if prtSonetStm1MngSameIpAsHost=no."
::= { prtSonetStm1Entry 15 }
prtSonetStm1MngIpSubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines IP subnet mask for DCC management
for this link, together with prtSonetStm1MngIpAddress
This parameter is applicable only if prtSonetStm1MngSameIp=no"
::= { prtSonetStm1Entry 16 }
prtSonetStm1MngDefaultGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines default Gateway address for DCC management
for this link.
This parameter is applicable only if prtSonetStm1MngSameIp=no"
::= { prtSonetStm1Entry 17 }
--SONET/SDH VC-3, VC-4 and VC-12 ports parameters
prtSonetVc OBJECT IDENTIFIER ::= {prtSonetConfig 3}
prtSonetVcTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSonetVcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Sonet/SDH VC port configuration table."
::= { prtSonetVc 1}
prtSonetVcEntry OBJECT-TYPE
SYNTAX PrtSonetVcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry in the Sonet/SDH VC port configuration table."
INDEX { prtSonetVcCnfgIdx, prtSonetVcIdx }
::= { prtSonetVcTable 1}
PrtSonetVcEntry ::=
SEQUENCE {
prtSonetVcCnfgIdx
Integer32,
prtSonetVcIdx
Integer32,
prtSonetVcJTxPathTraceEnable
INTEGER,
prtSonetVcJRxPathTraceEnable
INTEGER,
prtSonetVcJPathTrace
DisplayString,
prtSonetVcConnect
INTEGER,
prtSonetVcSignalLabel
OCTET STRING,
prtSonetVcPathTracePadding
INTEGER,
prtSonetVcPayloadBlockOnPathTrace
INTEGER,
prtSonetVcPayloadType
INTEGER,
prtSonetVcPathTraceSize
INTEGER
}
prtSonetVcCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
For products that support several configurations, Set can be performed
only to the Temporary Config (=255). "
::= { prtSonetVcEntry 1}
prtSonetVcIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique port or interface number.
For numbering, see product's spec.
For some products, the numbering can equal ifIndex."
::= { prtSonetVcEntry 2}
prtSonetVcJTxPathTraceEnable OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable Transmitting Jy Path Trace. y=1, 2:
J1 - for VC-4 layer
J2 - for VC-12 layer."
::= { prtSonetVcEntry 3 }
prtSonetVcJRxPathTraceEnable OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable checking Jy Path Trace. y=1, 2:
J1 - for VC-4 layer
J2 - for VC-12 layer."
::= { prtSonetVcEntry 4 }
prtSonetVcJPathTrace OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..62))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Jy Path Trace. y=1, 2:
J1 - for VC-4 layer
J2 - for VC-12 layer.
This object is applicable only if one of the previous 2 objects is 'enable'."
::= { prtSonetVcEntry 5 }
prtSonetVcConnect OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Connect VCn (n - 11,12,2,3,4) port (yes/no)."
::= { prtSonetVcEntry 6 }
prtSonetVcSignalLabel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Signal Label.
For VC-3:
The SONET standard defines the C2 byte as
the path signal label. The purpose of this byte is to
communicate the payload type being encapsulated by the
SONET Framing OverHead. It allows a single interface to
transport multiple payload types simultaneously.
For VC-12, VT-1.5:
VT path overhead V5 byte allocates bits 5-7 for
VT Path Signal Label, to indicate the content of the VT SPE.
000 Unequipped
001 Equipped : non-specific payload
010 Asynchronous mapping
011 Bit synchronous mapping (no longer valid for DS1)
100 Byte synchronous mapping
101 Unassigned
110 Unassigned
111 Unassigned
Agents that do not support this feature will send SIZE 0."
::= { prtSonetVcEntry 7 }
prtSonetVcPathTracePadding OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
nuls (2),
spaces (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Padding character will pad prtSonetVcJPathTrace string
to fill required number of characters."
::= { prtSonetVcEntry 8 }
prtSonetVcPayloadBlockOnPathTrace OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Block payload on this VC upon PathTrace (TIM)."
::= { prtSonetVcEntry 9 }
prtSonetVcPayloadType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
pos (2),
clearchannel (3),
channelized (4),
vc1x (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Payload type, applicable for STS-1/TUG-3 layer.
vc1x = vc12 or vc11 for SDH, VT1.5, VT2 for SONET.
clear channel - complete TUG-3 or STS-1
For Egate-100:
POS (Packets over Sonet) configuration is valid per STM1/OC3,
change this mode to POS for one TUG3/STS1 change values
to POS for all TUG3/STS1 under this STM1/OC3.
Clear Channel/channelize/ configuration is valid per TUG3/STS1."
::= { prtSonetVcEntry 10 }
prtSonetVcPathTraceSize OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
b16 (2),
b64 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Path Trace Size in Bytes - 16 or 64."
::= { prtSonetVcEntry 11 }
--TU-12 (within VC-4) Connect Table
prtSonetTuTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSonetTuEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table's Objects is valid only
for the TmpCnfg entry (Scratch)."
::= { prtSonetVc 2}
prtSonetTuEntry OBJECT-TYPE
SYNTAX PrtSonetTuEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtSonetTuCnfgIdx, prtSonetTuPrtIdx, prtSonetTuIdx, prtSonetTuConPrtIdx }
::= { prtSonetTuTable 1}
PrtSonetTuEntry ::=
SEQUENCE {
prtSonetTuCnfgIdx Integer32,
prtSonetTuPrtIdx Integer32,
prtSonetTuIdx Integer32,
prtSonetTuConPrtIdx Integer32,
prtSonetTuType INTEGER,
prtSonetTuMode INTEGER,
prtSonetTuRowStatus RowStatus
}
prtSonetTuCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
For products that support several configurations, Set can be performed
only to the Temporary Config (=255). "
::= { prtSonetTuEntry 1}
prtSonetTuPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique port or interface number.
For port numbering, see product's spec.
For some products, the numbering can equal ifIndex."
::= { prtSonetTuEntry 2}
prtSonetTuIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique TU (Tributary Unit) within VC-4.
The valid TUs are 1..63."
::= { prtSonetTuEntry 3}
prtSonetTuConPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the connected port, when prtSonetTuType=connect.
For port numbering, see product's spec.
For some products, the numbering can equal ifIndex.
notApplicable - will be indicated as 100."
::= {prtSonetTuEntry 4}
prtSonetTuType OBJECT-TYPE
SYNTAX INTEGER
{
connect (2),
bypass (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of TU (Tributary Unit).
connect - connected to one of the E1 ports.
bypass - bypassed to the other VC4 port.
TUs that are not connected or bypassed, will not exist in this table."
::= { prtSonetTuEntry 5}
prtSonetTuMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
addAndDrop (2),
add (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"TU Mode of connection.
addAndDrop - Add & Drop
add - Add (TU receives from the E1 ports)."
::= { prtSonetTuEntry 6}
prtSonetTuRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= { prtSonetTuEntry 7}
-- SDH Cross Connect Table
-- May be used also for SONET
prtSonetXConnect OBJECT IDENTIFIER ::= {sonetInterface 3}
prtSonetXConnectTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSonetXConnectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table's Objects is valid only
for the TmpCnfg entry (Scratch)."
::= { prtSonetXConnect 1}
prtSonetXConnectEntry OBJECT-TYPE
SYNTAX PrtSonetXConnectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {
prtSonetXConnectCnfgIdx,
prtSonetXConnectPrtIdx,
prtSonetXConnectConPrtIdx,
prtSonetXConnectAUGIdx,
prtSonetXConnectTUG3Idx,
prtSonetXConnectTUG2Idx,
prtSonetXConnectTUnIdx
}
::= { prtSonetXConnectTable 1}
PrtSonetXConnectEntry ::=
SEQUENCE {
prtSonetXConnectCnfgIdx Integer32,
prtSonetXConnectPrtIdx Integer32,
prtSonetXConnectConPrtIdx Integer32,
prtSonetXConnectAUGIdx Integer32,
prtSonetXConnectTUG3Idx Integer32,
prtSonetXConnectTUG2Idx Integer32,
prtSonetXConnectTUnIdx Integer32,
prtSonetXConnectRowStatus RowStatus,
prtSonetXConnectDirection INTEGER,
prtSonetXConnectTuNumber INTEGER,
prtSonetXConnectMode INTEGER
}
prtSonetXConnectCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
For products that support several configurations, Set can be performed
only to the Temporary Config (=255). "
::= { prtSonetXConnectEntry 1}
prtSonetXConnectPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique port or interface number.
For port numbering, see product's spec.
For some products, the numbering can equal ifIndex."
::= { prtSonetXConnectEntry 2}
prtSonetXConnectConPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the connected port.
For port numbering, see product's spec.
For some products, the numbering can equal ifIndex.
notApplicable - will be indicated as 255."
::= {prtSonetXConnectEntry 3}
prtSonetXConnectAUGIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates an AUG (Administrative Unit Group) within STM-N.
The valid AUGs values are:
1 for STM-1
1...4 for STM-4,
1..16 for STM-16 and
1..64 for STM-64 (STM-64)
255 designates NA."
::= { prtSonetXConnectEntry 4}
prtSonetXConnectTUG3Idx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a TUG-3 (Tributary Unit Group 3) within VC-4.
The valid TUG3s are values are 1..3. and 255 which designates NA "
::= { prtSonetXConnectEntry 5}
prtSonetXConnectTUG2Idx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a TUG2 (Tributary Unit Group 2 ) within VC-3.
The valid TUG2's values are 1..7 and 255 which designates NA "
::= { prtSonetXConnectEntry 6}
prtSonetXConnectTUnIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a TUn within TUG-2 or TUG-3
(Tributary Unit n, where n is 2, 12 or 11 within TUG-2,
or 3 within TUG-3)
valid values are
1 for TU-2
1 for TU-3
1..4 for TU-11
1..3 for TU-12
255 designates NA"
::= { prtSonetXConnectEntry 7}
prtSonetXConnectRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= { prtSonetXConnectEntry 8}
prtSonetXConnectDirection OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
rx (2),
tx (3),
both (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"TU direction of connection.
rx=Drop
tx=Add
both = Add & Drop"
::= { prtSonetXConnectEntry 9}
prtSonetXConnectTuNumber OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
tu2 (2),
tu3 (3),
tu11 (4),
tu12 (5),
tuFour4c (6),
sts12c (7)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates which TU is used in prtSonetXConnectTUnIdx "
::= { prtSonetXConnectEntry 10}
prtSonetXConnectMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
addAndDrop (2),
bypass (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"TU Mode of connection.
addAndDrop - Add & Drop
bypass - bypassed to the other VC4 port."
::= {prtSonetXConnectEntry 11}
prtSonetStatus OBJECT IDENTIFIER ::= {sonetInterface 4}
prtSonetVcStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSonetVcStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"VC Status Table "
::= { prtSonetStatus 1 }
prtSonetVcStatEntry OBJECT-TYPE
SYNTAX PrtSonetVcStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the VC status Table."
INDEX {prtSonetVcIdx}
::= { prtSonetVcStatTable 1 }
PrtSonetVcStatEntry ::=
SEQUENCE {
prtSonetVcRxJPathTrace SnmpAdminString,
prtSonetVcRxSignalLabel OCTET STRING,
prtSonetVcLcasSourceState INTEGER,
prtSonetVcLcasSinkState INTEGER,
prtSonetVcStatus Integer32,
prtSonetVcRxSeqNumber Unsigned32,
prtSonetVcTxSeqNumber Unsigned32,
prtSonetVcMfiDiffDelay Unsigned32,
prtSonetVcLoMF INTEGER,
prtSonetVcLoopStatus INTEGER,
prtSonetVcLcasTxStateMachineStatus INTEGER,
prtSonetVcLcasRxStateMachineStatus INTEGER,
prtSonetVcMFLengthErrorCounter Counter32,
prtSonetVcCntrlPktCRCErrorCounter Counter32
}
prtSonetVcRxJPathTrace OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..62))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Jy Path Trace value received from network.
y=1, 2:
J1 - for VC-4 layer
J2 - for VC-12 layer."
::= { prtSonetVcStatEntry 1 }
prtSonetVcRxSignalLabel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal Label received from network.
For VC-3:
The SONET standard defines the C2 byte as
the path signal label. The purpose of this byte is to
communicate the payload type being encapsulated by the
SONET Framing OverHead. It allows a single interface to
transport multiple payload types simultaneously.
For VC-12, VT-1.5:
VT path overhead V5 byte allocates bits 5-7 for
VT Path Signal Label, to indicate the content of the VT SPE.
000 - Unequipped
001 - Equipped - non specific payload
010 - Asynchronous Mapping
011 - Bit Synchronous Mapping (no longer used)
100 - Byte Synchronous Mapping (TU11 or TU12)
101 - Extended Signal Label for Virtual
Concatenation Applications (FCD-155 Default)
110 - Test Signal (0.181) (ITU)
111 - VC AIS (ITU)"
::= { prtSonetVcStatEntry 2 }
prtSonetVcLcasSourceState OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
fixed (2),
add (3),
norm (4),
eos (5),
idle (6),
dnu (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fixed - This is an indication that this end
uses fixed bandwidth (non-LCAS mode)
Add - This member is about to be added to the group
Norm - Normal transmission.
EOS - End of Sequence indication
and Normal transmission.
Idle - IDLE This member is not part of
the group or about to be removed.
Dnu - Do Not use - Do Not Use (the payload)
the Sk side reported FAIL status."
::= { prtSonetVcStatEntry 3}
prtSonetVcLcasSinkState OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
fixed (2),
add (3),
norm (4),
eos (5),
idle (6),
dnu (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fixed - This is an indication that this end
uses fixed bandwidth (non-LCAS mode)
Add - This member is about to be added to the group
Norm - Normal transmission.
EOS - End of Sequence indication
and Normal transmission.
Idle - IDLE This member is not part of
the group or about to be removed.
Dnu - Do Not use - Do Not Use (the payload)
the Sk side reported FAIL status."
::= { prtSonetVcStatEntry 4}
prtSonetVcStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the Status of the interface.
It contains failure state information.
The variable is a bit map represented as a sum, therefore, it
can represent multiple failures simultaneously.
The sonetVCNoDefect must be set if and only if no other flag is set.
The various bit positions are:
1 sonetVCNoDefect No alarm present
2 sonetVCLOP Loss Of Pointer
4 sonetVCPathAIS Alarm Indication Signal
8 sonetVCPathRDI Remote Defect Indication
16 sonetVCPathRFI Remote Failure Indication
(RDI lasts for 2.5 (+-0.5) seconds)
32 sonetVCUnequipped Signal Label Unequipped
64 sonetVCSignalLabelMismatch Signal Label Mismatch
128 sonetVCEBER Excessive Bit Error Rate
256 sonetVCSD Signal Degradation."
::= { prtSonetVcStatEntry 5 }
prtSonetVcRxSeqNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indeticates the LCAS Rx
sequence number of this VC."
::= { prtSonetVcStatEntry 6 }
prtSonetVcTxSeqNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the LCAS Tx sequence number of this VC."
::= { prtSonetVcStatEntry 7 }
prtSonetVcMfiDiffDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates time difference (based on MFI field) from the
fastest channel (on which it will be 0), in miliSeconds units"
::= { prtSonetVcStatEntry 8 }
prtSonetVcLoMF OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off (2), -- OK
on (3) -- Loss of Multiframe defect
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates loss of Multiframe defect."
::= { prtSonetVcStatEntry 9 }
prtSonetVcLoopStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off (2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates Loop Status."
::= { prtSonetVcStatEntry 10 }
prtSonetVcLcasTxStateMachineStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
-- fixed (2),
add (3),
norm (4),
-- eos (5),
idle (6),
dnu (7),
remove (8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LCAS State machine status."
::= { prtSonetVcStatEntry 11}
prtSonetVcLcasRxStateMachineStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
-- fixed (2),
-- add (3),
-- norm (4),
-- eos (5),
idle (6),
-- dnu (7),
ok (9),
fail (10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LCAS State machine status."
::= { prtSonetVcStatEntry 12}
prtSonetVcMFLengthErrorCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counts the multi-frames that had wrong length (shorter or longer)"
::= { prtSonetVcStatEntry 13 }
prtSonetVcCntrlPktCRCErrorCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counts Number of Control Packet CRC errors"
::= { prtSonetVcStatEntry 14 }
prtSonetPathProtTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSonetPathProtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Path Protection Monitoring Table "
::= { prtSonetStatus 2 }
prtSonetPathProtEntry OBJECT-TYPE
SYNTAX PrtSonetPathProtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Path Protection monitoring Table.
This table indicates for each protected interface
which VCs are mapped as Working VC,
which VCs are mapped as Protection VC,
and which of them are currently active."
INDEX {prtSonetPathProtProtectedInterface,prtSonetPathProtIdx}
::= { prtSonetPathProtTable 1 }
PrtSonetPathProtEntry ::=
SEQUENCE {
prtSonetPathProtProtectedInterface InterfaceIndex,
prtSonetPathProtIdx Unsigned32,
prtSonetPathProtWorkingVc Unsigned32,
prtSonetPathProtProtectionVc Unsigned32,
prtSonetPathProtActiveVc INTEGER
}
prtSonetPathProtProtectedInterface OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interface protected by path-protection,
e.g. PDH (E1/T1/E3/T3) port, VCG (Virtual Concatenation Group)."
::= { prtSonetPathProtEntry 1 }
prtSonetPathProtIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Runing index of entries which are mapped
to a specific interface, indicated by PrtSonetPathProtProtectedInterface.
e.g - multiple working VCs and protection VCs are mapped to single
Virtual Concatenation Group (VCG)."
::= { prtSonetPathProtEntry 2 }
prtSonetPathProtWorkingVc OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A VC mapped to interface indicated by
prtSonetPathProtProtectedInterface as
working VC. The value of this object may be
equal to the value of ifIndex of working VC "
::= { prtSonetPathProtEntry 3 }
prtSonetPathProtProtectionVc OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A VC mapped to interface indicated by
prtSonetPathProtProtectedInterface
as protection VC. The value of this object may be
equal to the value of ifIndex of protection VC "
::= { prtSonetPathProtEntry 4 }
prtSonetPathProtActiveVc OBJECT-TYPE
SYNTAX INTEGER
{
working (2),
protection (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates which of the path protection
VCs is currently active."
::= { prtSonetPathProtEntry 5 }
vcGroupStat OBJECT IDENTIFIER ::= {sonetInterface 6}
vcGroupStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF VcGroupStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Sonet/SDH VCG status table."
::= { vcGroupStat 1}
vcGroupStatEntry OBJECT-TYPE
SYNTAX VcGroupStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry in the Sonet/SDH VCG gen staus table."
INDEX { ifIndex }
::= { vcGroupStatTable 1}
VcGroupStatEntry ::=
SEQUENCE {
vcGroupStatRemoteChannelStatus OCTET STRING
}
vcGroupStatRemoteChannelStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of remote VCG channels as received in the local station,
represented by 1 bit per channel. Refer to product spec for details."
::= { vcGroupStatEntry 1}
radAps OBJECT IDENTIFIER ::= { sonetInterface 5 }
radApsEvents OBJECT IDENTIFIER ::= { radAps 0 }
apsActiveChannelTrap NOTIFICATION-TYPE
OBJECTS { radApsStatusCurrentWorkingChannel }
STATUS current
DESCRIPTION
"The trap is sent upon change of Active Channel of APS Group."
::= { radApsEvents 1 }
radApsConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadApsConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Augment to the APS Configuration Table
(apsConfigTable in APS-MIB)."
::= { radAps 1 }
radApsConfigEntry OBJECT-TYPE
SYNTAX RadApsConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
AUGMENTS { apsConfigEntry }
::= { radApsConfigTable 1 }
RadApsConfigEntry ::=
SEQUENCE {
radApsConfigClearCounters INTEGER,
radApsConfigCommandAndStatus INTEGER,
radApsConfigFlipOnSD INTEGER
}
radApsConfigClearCounters OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Setting this object to on(3) will clear APS Counters.
Upon performing this operation, the value will be
automatically changed to off(2)."
::= { radApsConfigEntry 1}
radApsConfigCommandAndStatus OBJECT-TYPE
SYNTAX INTEGER {
noOp (1),
clear (2),
forcedSwitch (3),
lockout (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"noOp - initial state only (cannot be Set by user).
clear - clearing the last performed command.
Can be Set only if previous state was other than noOp or clear.
forcedSwitch - transferring service from primary channel to the secondary channel.
Can be Set only if previous state was noOp or clear.
If the non-Active channel is failed, the command will be rejected.
lockout - freezing the current state.
In 1+1 Bidirectional Optimized switching, Lockout is considered
as a local request which is not signalled across the K-bytes.
The effect of lockout is to freeze the selector position
and transmitted K-bytes until the lockout request is cleared.
Can be Set only if previous state was noOp or Clear."
::= { radApsConfigEntry 2}
radApsConfigFlipOnSD OBJECT-TYPE
SYNTAX INTEGER {
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Flip active channel according to SD (Signal Degradation)."
::= { radApsConfigEntry 3}
radApsStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadApsStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Augment to the APS Status Table
(apsStatusTable in APS-MIB)."
::= { radAps 2 }
radApsStatusEntry OBJECT-TYPE
SYNTAX RadApsStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
AUGMENTS { apsConfigEntry }
::= { radApsStatusTable 1 }
RadApsStatusEntry ::=
SEQUENCE {
radApsStatusCurrentWorkingChannel Integer32
}
radApsStatusCurrentWorkingChannel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the port/interface index of
the Current Working Channel."
::= { radApsStatusEntry 1}
prtVcGroupCnfg OBJECT IDENTIFIER ::= {prtSonetConfig 4}
vcGroupCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF VcGroupCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Concatenation Group configuration table."
::= { prtVcGroupCnfg 1 }
vcGroupCnfgEntry OBJECT-TYPE
SYNTAX VcGroupCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Concatenation Group
configuration table."
INDEX { vcGroupCnfgIdx,vcGroupCnfgNumber}
::= { vcGroupCnfgTable 1 }
VcGroupCnfgEntry ::=
SEQUENCE {
vcGroupCnfgIdx Integer32,
vcGroupCnfgNumber Integer32,
vcGroupCnfgRowStatus RowStatus,
vcGroupCnfgVcType INTEGER,
vcGroupCnfgNoOfVCs Integer32,
vcGroupCnfgLCAS INTEGER,
vcGroupCnfgEncapsulation INTEGER,
vcGroupCnfgGroupIfIndex InterfaceIndex,
vcGroupCnfgRip2 INTEGER,
vcGroupCnfgGfpChId Integer32,
vcGroupCnfgK4 INTEGER,
vcGroupCnfgExSignalLabel OCTET STRING,
vcGroupCnfgLcasMinNoOfVCs Integer32,
vcGroupCnfgLcasStatus INTEGER,
vcGroupCnfgMappingMode INTEGER,
vcGroupCnfgTrafficType INTEGER,
vcGroupCnfgGroupName SnmpAdminString,
vcGroupCnfgLoopDetection INTEGER,
vcGroupCnfgLcasWaitToRestore Unsigned32,
vcGroupCnfgLcasHoldOff Unsigned32
}
vcGroupCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
For products that support several configurations, Set can be performed
only to the Temporary Config (=255). "
::= { vcGroupCnfgEntry 1}
vcGroupCnfgNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Virtual Concatenation Group Number.
For FCD-155 up to eight groups are defined
valid values are 1..8.
For MP-4100, group ifIndex is used."
::= { vcGroupCnfgEntry 2}
vcGroupCnfgRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= { vcGroupCnfgEntry 3}
vcGroupCnfgVcType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
vc12 (2), --SDH
vc3 (3), --SDH
vc4 (4), --SDH
vt1dot5 (5), --SONET VT1.5
sts1 (6), --SONET STS1 /SPE
sts12c (7), --STS12c
vcFour4c (8) --VC4-4c
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"User may select type of SDH Virtual Containers (VC)
(SONET Virtual Tributaries VT ) to be concatenated
in this Virtual Concatenation Group.
For SDH, values 2,3,4 and 8 are valid.
For SONET, values 5, 6,7 are valid."
::= { vcGroupCnfgEntry 4}
vcGroupCnfgNoOfVCs OBJECT-TYPE
SYNTAX Integer32 (0..84)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"User may select number of Virtual Containers (VC)
(SONET Virtual Tributaries VT ) to be concatenated
in this Virtual Concatenation Group.
Valid range for this number depends on
type VC selected by vcGroupCnfgVCType
For SDH, up to 63 VC12, or
up to 3 VC3, or
1 VC4 are valid
For SONET, up to 84 VT1.5 without LCAS,
or 64 VT1.5 under LCAS control.
or up tp 3 STS-1/SPE, or
1 STS-3"
::= { vcGroupCnfgEntry 5}
vcGroupCnfgLCAS OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
lcasNotActive (2),
lcasActive (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls Link Capacity Adjustment
Scheme (LCAS) activation."
::= { vcGroupCnfgEntry 6}
vcGroupCnfgEncapsulation OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
laps (2), -- Link access protocol S
lapf (3), -- Link access protocol F (Frame relay)
gfp (4) -- Generic Framing Procedure
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables user to select encapsulation method."
::= { vcGroupCnfgEntry 7}
vcGroupCnfgGroupIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex assigend to this group."
::= { vcGroupCnfgEntry 8}
vcGroupCnfgRip2 OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls RIP 2.
User may select to send RIP 2 message over
selected group or not"
::= { vcGroupCnfgEntry 9}
vcGroupCnfgGfpChId OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Generic Framing Procedure (GFP) Channel ID,
Valid only when vcGroupCnfgEncapsulation = gfp (4)
Valid values are 0x00 - oxFF (hex) "
::= { vcGroupCnfgEntry 10}
vcGroupCnfgK4 OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls whether K4 byte
(of Line Overhead) is used as an indication for
virtual concatenation (VCAT).
This object is applicable, when VCG
includes only a single Virtual Container (VC)
(or SONET VT) "
::= { vcGroupCnfgEntry 11}
vcGroupCnfgExSignalLabel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Extended Signal Label.
Relevant only when vcGroupCnfgK4 = yes(3).
Agents that do not support this feature will send SIZE 0."
::= { vcGroupCnfgEntry 12 }
vcGroupCnfgLcasMinNoOfVCs OBJECT-TYPE
SYNTAX Integer32 (0..83)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Minimum number of VC's to declare alarm, in LCAS mode.
Applicable only when LCAS is active
(vcGroupCnfgLCAS =lcasActive)
1...63 for SDH, 1...84 for SONET
0= not applicable. "
::= { vcGroupCnfgEntry 13}
vcGroupCnfgLcasStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
belowMinNoOfVCs (2),
withinRange (3),
allNorm (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object summarize LCAS states of all VCs in VCG:
belowMinNoOfVCs - Number of VCs in Norm state is less than
the minimum number of VCs
(indicated by vcGroupCnfgLcasMinNoOfVCs)
withinRange - Number of VCs in Norm state is higher than
the minimum number of VCs
indicated by vcGroupCnfgLcasMinNoOfVCs)
but is lower than Number of VCs mapped
allNorm - Number of VCs in Norm state equals
number of mapped VCs. "
::= { vcGroupCnfgEntry 14}
vcGroupCnfgMappingMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off (2),
auto (3),
manual (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object define Path Protection mode for VCG.
Auto - the entire mapping for Virtual Concatenation Group x
is copied automatically by agent for the protection group
to same TUs on the other SONET/SDH link which reside on same slot..
Manual - the user may configure mapping for the protection group
on the same link as for other group, or on the other link(s).
Same type of TUs should be used for both groups.
The TUs selected for each group don't have to be the same."
::= { vcGroupCnfgEntry 15}
vcGroupCnfgTrafficType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
managementOnly (2),
dataOnly (3),
mixed (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object allows to select traffic type for
specific VCG."
::= { vcGroupCnfgEntry 16}
vcGroupCnfgGroupName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Virtual Concatenation Group (VCG) Name.
String length is limited to 15 characters."
::= { vcGroupCnfgEntry 17}
vcGroupCnfgLoopDetection OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disabled (2),
enabeld (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VCAT Loop detecetion enabled."
::= { vcGroupCnfgEntry 18}
vcGroupCnfgLcasWaitToRestore OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Time duration (in milliseconds units) waited after
errors on channel stopped, before channel is reused."
::= { vcGroupCnfgEntry 19}
vcGroupCnfgLcasHoldOff OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Time duration (in milliseconds units) in which errors on channel
are disregarded. (Threshold)"
::= { vcGroupCnfgEntry 20}
vcgGfpMuxCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF VcgGfpMuxCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Concatenation Group GFP Mux configuration table."
::= { prtVcGroupCnfg 2 }
-- This table defines multiplexing scheme for GFP mux of
-- Virtual Concatenation Groups:
-- Primary group, Secondary group/s and bandwidth allocation
-- to each group.
vcgGfpMuxCnfgEntry OBJECT-TYPE
SYNTAX VcgGfpMuxCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Concatenation Group GFP Mux
configuration table."
INDEX { vcgGfpMuxCnfgIdx,vcgGfpMuxCnfgMuxNumber}
::= { vcgGfpMuxCnfgTable 1 }
VcgGfpMuxCnfgEntry ::=
SEQUENCE {
vcgGfpMuxCnfgIdx Integer32,
vcgGfpMuxCnfgMuxNumber Integer32,
vcgGfpMuxCnfgRowStatus RowStatus,
vcgGfpMuxCnfgMuxName SnmpAdminString,
vcgGfpMuxCnfgPrimeGroup Integer32,
vcgGfpMuxCnfgGrpBwAlloc OCTET STRING
}
vcgGfpMuxCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Index of the configuration being accessed.
Index of 255 relates to the Temporary (Scratch) coninguration.
For products that support several configurations, Set can be performed
only to the Temporary Config (=255). "
::= { vcgGfpMuxCnfgEntry 1}
vcgGfpMuxCnfgMuxNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Virtual Concatenation Group GFP Mux Number.
Refer to device specification for definition of
- maximum number of GFP-mux.
- concatenation of Slot and GFP mux number."
::= { vcgGfpMuxCnfgEntry 2}
vcgGfpMuxCnfgRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= { vcgGfpMuxCnfgEntry 3}
vcgGfpMuxCnfgMuxName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Virtual Concatenation Group, GFP Mux name."
::= { vcgGfpMuxCnfgEntry 4}
vcgGfpMuxCnfgPrimeGroup OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Index of Virtual Concatenation Group used as
Primary for the GFP mux created
for FCD 155 up to 8 Virtual Concatenation Group are defined:
1 -> Virtual Concatenation Group 1
2 -> Virtual Concatenation Group 2
3 -> Virtual Concatenation Group 3
4 -> Virtual Concatenation Group 4
5 -> Virtual Concatenation Group 5
6 -> Virtual Concatenation Group 6
7 -> Virtual Concatenation Group 7
8 -> Virtual Concatenation Group 8
"
::= { vcgGfpMuxCnfgEntry 5}
vcgGfpMuxCnfgGrpBwAlloc OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the allocated bandwidth (BW) to each
Virtual Concatenation Group (VCG).
Each nibble indicates BW percentage, in 12.5% steps,
assigned to a group.
For FCD-155, there may be 4 or 8 VCGs. When only 4 VCG exists,
only two octets are used.
In current GFP Mux,one VCG is identified as primary group
by vcGfpMuxConfPrimeGroup.
Other VCGs may be secondaries.
VCG with allocated BW value of zero does not belong to the GFPmux
defined by GFP Mux number.
________________________________________
| Octet 0 | Octet 1 |
|Nibble 4 | Nibble 3| Nibble 2| Nibble 1|
MSB | 7 6 5 4 | 3 2 1 0 | 7 6 5 4 | 3 2 1 0 |
+___________________+___________________+
VCG1 VCG2 VCG 3 VCG4
________________________________________
| Octet 3 | Octet 4 |
|Nibble 4 | Nibble 3| Nibble 2| Nibble 1|
| 7 6 5 4 | 3 2 1 0 | 7 6 5 4 | 3 2 1 0 | LSB
+___________________+___________________+
VCG5 VCG6 VCG 7 VCG8
Nibble value - BW Percentage
(0...7) (0 ...87.5%)
1 0001 12.5 %
2 0010 25%
3 0011 37.5
.....
7 0111 87.5%
at least one nibble must be greater that zero.
Sum of alloacted BW must be 100%.
Primary VCG BW must be greater than zero."
::= { vcgGfpMuxCnfgEntry 6}
virtualIfConfiguration OBJECT IDENTIFIER ::= { prtSonetConfig 5}
virtualIfGenTable OBJECT-TYPE
SYNTAX SEQUENCE OF VirtualIfGenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Sonet/SDH general port configuration table."
::= { virtualIfConfiguration 1}
virtualIfGenEntry OBJECT-TYPE
SYNTAX VirtualIfGenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry in the Sonet/SDH general port configuration table."
INDEX { virtualIfGenCnfgIdx, virtualIfGenIdx }
::= { virtualIfGenTable 1}
VirtualIfGenEntry ::=
SEQUENCE {
virtualIfGenCnfgIdx
Integer32,
virtualIfGenIdx
Integer32,
virtualIfGenFrameFormat
INTEGER
}
virtualIfGenCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
For products that support several configurations, Set can be performed
only to the Temporary Config (=255). "
::= { virtualIfGenEntry 1}
virtualIfGenIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique port or interface number.
For numbering, see product's spec.
For some products, the numbering can equal ifIndex."
::= { virtualIfGenEntry 2}
virtualIfGenFrameFormat OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
fcsEnable (2),
fcsDisable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The frame format.
fcsEnabe = Frame will be sent with the FCS bits.
fcsDisable = Frame will be sent without the FCS bits ."
::= { virtualIfGenEntry 3 }
-- NOTIFICATIONs
-- ALARM TRAPS
sonetAlarmLOS NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates Loss Of Signal."
::= { prtSonetEvents 1 }
sonetAlarmLOF NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates Loss Of Frame."
::= { prtSonetEvents 2 }
sonetAlarmOOF NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates Out Of Frame."
::= { prtSonetEvents 3 }
sonetAlarmLineAIS NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates Line Alarm Indication Signal."
::= { prtSonetEvents 4 }
sonetAlarmLineEED NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates Line Excessive Error Detect."
::= { prtSonetEvents 5 }
sonetAlarmLineRDI NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates Line Remote Defect Indication."
::= { prtSonetEvents 6 }
sonetAlarmLineSD NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates Line Signal Degrade."
::= { prtSonetEvents 7 }
sonetAlarmPathLOP NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates Path Loss of Pointer."
::= { prtSonetEvents 8 }
sonetAlarmPathAIS NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates Path Alarm Indication Signal."
::= { prtSonetEvents 9 }
sonetAlarmPathEED NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates Path Excessive Error Detect."
::= { prtSonetEvents 10 }
sonetAlarmPathSLM NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates Path Signal Label Mismatch."
::= { prtSonetEvents 11 }
sonetAlarmPathLOMF NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates Path Loss of Multi-Frame."
::= { prtSonetEvents 12 }
sonetAlarmPathRDI NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates Path Remote Defect Indication."
::= { prtSonetEvents 13 }
sonetAlarmPathSD NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates Path Signal Degrade."
::= { prtSonetEvents 14 }
sonetAlarmVtLOP NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates VT Loss of Pointer."
::= { prtSonetEvents 15 }
sonetAlarmVtAIS NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates VT Alarm Indication Signal."
::= { prtSonetEvents 16 }
sonetAlarmVtEED NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates VT Excessive Error Detect."
::= { prtSonetEvents 17 }
sonetAlarmVtSLM NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates VT Signal Label Mismatch."
::= { prtSonetEvents 18 }
sonetAlarmVtRDI NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates VT Remote Defect Indication."
::= { prtSonetEvents 19 }
sonetAlarmVtSD NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates VT Signal Degrade."
::= { prtSonetEvents 20 }
-- END--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\radds1.txt
--
-- RAD-DS1-MIB DEFINITIONS ::= BEGIN
--Title: RAD-DS1 MIB
--
-- Copyright 1998 RAD Data Communications, Ltd.
-- All Rights Reserved.
-- IMPORTS
-- PerfCurrentCount, PerfIntervalCount FROM PerfHist-TC-MIB;
-- OBJECT-TYPE FROM RFC-1212
-- radWan FROM RAD-GEN-MIB;
-- RAD-DS1 MIB
--Title: RAD's DS1 INTERFACE MIB
--Date: 03.02.98
--By: Ilana Schvetz
--File: radds1.mib
-- Last updated by Yig'al Hachmon 12-May-2008
ds1Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 4}
prtDS1Events OBJECT IDENTIFIER ::= {ds1Interface 0}
prtDs1PerfHistory OBJECT IDENTIFIER ::= {ds1Interface 1}
-- Extension to the dsx1 current table
dsx1XCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx1XCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of current statistics entries. This table
contains additional objects for the current table."
::= { prtDs1PerfHistory 2 }
dsx1XCurrentEntry OBJECT-TYPE
SYNTAX Dsx1XCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing additional statistical counters
applicable to a particular current table."
-- AUGMENTS { dsx1CurrentEntry }
INDEX { dsx1CurrentIndex }
::= { dsx1XCurrentTable 1 }
Dsx1XCurrentEntry ::=
SEQUENCE {
dsx1CurrentLOS PerfCurrentCount,
dsx1CurrentLOF PerfCurrentCount,
dsx1CurrentLOC PerfCurrentCount,
dsx1CurrentAIS PerfCurrentCount,
dsx1CurrentRAI PerfCurrentCount,
dsx1CurrentLOMF PerfCurrentCount,
dsx1CurrentFEBE PerfCurrentCount,
dsx1CurrentStatus OCTET STRING,
dsx1CurrentBPV PerfCurrentCount,
dsx1CurrentLOCRCMF PerfCurrentCount,
dsx1CurrentLOFC PerfCurrentCount,
dsx1CurrentCRCErrors PerfCurrentCount
}
dsx1CurrentLOS OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOS
seconds, encountered by a DS1 interface in
the current 15 minute interval."
::= { dsx1XCurrentEntry 1 }
dsx1CurrentLOF OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOF
seconds, encountered by a DS1
interface in the current 15 minute interval."
::= { dsx1XCurrentEntry 2 }
dsx1CurrentLOC OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Loss Of Cell delineation. Counts number of cells the ATM UNI cells receiver
lost cells delineation ."
::= { dsx1XCurrentEntry 3 }
dsx1CurrentAIS OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of AIS
seconds, encountered by a DS1
interface in the current 15 minute interval."
::= { dsx1XCurrentEntry 4 }
dsx1CurrentRAI OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remote Alarm Indication: Transmitted in the outgoing direction
(toward the PABX) over FDL bits when the DS1 device detected
an incoming Loss Of Frame. Received from the far end (PABX)
over FDL when it detects a Loss of frame."
::= { dsx1XCurrentEntry 5 }
dsx1CurrentLOMF OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loss of Multi-Frame sequence in E1 time slot 16."
::= { dsx1XCurrentEntry 6 }
dsx1CurrentFEBE OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Far End Block Errors, as reported in the first bit
of frames 13 and 15, on multiframe E1 lines with CRC4,
in the current 15 minute interval."
::= { dsx1XCurrentEntry 7 }
dsx1CurrentStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statuses of the current interval:
0 - Valid.
1 - redundantLinkSwitch - the link has been switched
by a redundancy mechanism.
2 - discontinuity - module was partialy out.
4 - notValid - module is out."
::= { dsx1XCurrentEntry 8 }
dsx1CurrentBPV OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of BPVs (Bi-Polar Violations)
encountered by a DS1 interface in the current 15 minute interval."
::= { dsx1XCurrentEntry 9 }
dsx1CurrentLOCRCMF OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loss of CRC4 Multi-Frame sequence in E1.
encountered in the current 15 minute interval"
::= { dsx1XCurrentEntry 10 }
dsx1CurrentLOFC OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counts the number of loss of frame events measured.
encountered in the current 15 minute interval"
::= { dsx1XCurrentEntry 11 }
dsx1CurrentCRCErrors OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counts the number of CRC error events,
encountered in the current 15 minute interval."
::= { dsx1XCurrentEntry 12 }
-- Interval table
dsx1XIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx1XIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A list of Interval entries. This table
contains additional objects for the interval table."
::= { prtDs1PerfHistory 3 }
dsx1XIntervalEntry OBJECT-TYPE
SYNTAX Dsx1XIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing additional statistical counters
applicable to a particular interval table."
-- AUGMENTS { dsx1IntervalEntry }
INDEX { dsx1IntervalIndex, dsx1IntervalNumber }
::= { dsx1XIntervalTable 1 }
Dsx1XIntervalEntry ::=
SEQUENCE {
dsx1IntervalLOS PerfIntervalCount,
dsx1IntervalLOF PerfIntervalCount,
dsx1IntervalLOC PerfIntervalCount,
dsx1IntervalAIS PerfIntervalCount,
dsx1IntervalRAI PerfIntervalCount,
dsx1IntervalLOMF PerfIntervalCount,
dsx1IntervalFEBE PerfIntervalCount,
dsx1IntervalStatus OCTET STRING,
dsx1IntervalBPV PerfIntervalCount,
dsx1IntervalLOCRCMF PerfIntervalCount,
dsx1IntervalLOFC PerfIntervalCount
}
dsx1IntervalLOS OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOS
seconds , encountered by a DS1 interface in
one of the previous 96, individual 15 minute,
intervals."
::= { dsx1XIntervalEntry 1 }
dsx1IntervalLOF OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of OOF
seconds, encountered by a DS1
interface in one of the previous 96, individual 15
minute, intervals."
::= { dsx1XIntervalEntry 2 }
dsx1IntervalLOC OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Loss Of Cell delineation. Counts number of cells the ATM UNI cells receiver
lost cells delineation ."
::= { dsx1XIntervalEntry 3 }
dsx1IntervalAIS OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of AIS
seconds, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { dsx1XIntervalEntry 4 }
dsx1IntervalRAI OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remote Alarm Indication: Transmitted in the outgoing direction
(toward the PABX) over FDL bits when the DS1 device detected
an incoming Loss Of Frame. Received from the far end (PABX)
over FDL when it detects a Loss of frame."
::= { dsx1XIntervalEntry 5 }
dsx1IntervalLOMF OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loss of Multi-Frame sequence in E1 time slot 16."
::= { dsx1XIntervalEntry 6 }
dsx1IntervalFEBE OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Far End Block Errors, as reported in the first bit
of frames 13 and 15, on multiframe E1 lines with CRC4,
in one of the previous 96, individual, 15 minute intervals."
::= { dsx1XIntervalEntry 7 }
dsx1IntervalStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statuses of the current interval:
0 - Valid.
1 - redundantLinkSwitch - the link has been switched
by a redundancy mechanism.
2 - discontinuity - module was partialy out.
4 - notValid - module is out."
::= { dsx1XIntervalEntry 8 }
dsx1IntervalBPV OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of BPV (Bi-Polar Violations)
encountered by a DS1 interface in one of the previous 96,
individual 15 minute, intervals."
::= { dsx1XIntervalEntry 9 }
dsx1IntervalLOCRCMF OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loss of CRC4 Multi-Frame sequence in E1."
::= { dsx1XIntervalEntry 10 }
dsx1IntervalLOFC OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counts the number of loss of frame events measured
in one of the previous 96, individual 15 minute, intervals."
::= { dsx1XIntervalEntry 11 }
-- Extension to the dsx1 Total table
dsx1XTotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx1XTotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Total statistics entries. This table
contains additional objects for the Total table."
::= { prtDs1PerfHistory 4 }
dsx1XTotalEntry OBJECT-TYPE
SYNTAX Dsx1XTotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing additional statistical counters
applicable to a particular current table."
-- AUGMENTS { dsx1CurrentEntry }
INDEX { dsx1TotalIndex }
::= { dsx1XTotalTable 1 }
Dsx1XTotalEntry ::=
SEQUENCE {
dsx1TotalLOS PerfTotalCount,
dsx1TotalBPV PerfTotalCount,
dsx1TotalLOFC PerfTotalCount
}
dsx1TotalLOS OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOS (Loss of Signal)
seconds encountered by a DS1 interface in the previous
24 hour interval.
Invalid 15 minute intervals count as 0."
::= { dsx1XTotalEntry 1 }
dsx1TotalBPV OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of BPV (Bi-Polar Violations)
encountered by a DS1 interface in the previous 24 hour interval.
Invalid 15 minute intervals count as 0."
::= { dsx1XTotalEntry 9 }
dsx1TotalLOFC OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number loss of frames
encountered by a DS1 interface in the previous 24 hour interval.
Invalid 15 minute intervals count as 0."
::= { dsx1XTotalEntry 11 }
-- DS1 Data Stream Statistics Table
dsx1DataStreamStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx1DataStreamStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS1 Data Stream Statistics table."
::= { prtDs1PerfHistory 5 }
dsx1DataStreamStatEntry OBJECT-TYPE
SYNTAX Dsx1DataStreamStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS1 Data Stream Statistics table."
INDEX { dsx1DataStreamStatIfIndex, dsx1DataStreamStatIndex }
::= { dsx1DataStreamStatTable 1 }
Dsx1DataStreamStatEntry ::=
SEQUENCE {
dsx1DataStreamStatIfIndex Integer32,
dsx1DataStreamStatIndex Integer32,
dsx1DataStreamStatValid TruthValue,
dsx1DataStreamStatInFrames Counter32,
dsx1DataStreamStatInBytes Counter32,
dsx1DataStreamStatInDiscards Counter32,
dsx1DataStreamStatInErrors Counter32,
dsx1DataStreamStatOutFrames Counter32,
dsx1DataStreamStatOutBytes Counter32,
dsx1DataStreamStatOutDiscards Counter32,
dsx1DataStreamStatOutErrors Counter32
}
dsx1DataStreamStatIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the DS1 interface.
It may be ifIndex."
::= { dsx1DataStreamStatEntry 1 }
dsx1DataStreamStatIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS1 Data Stream Index.
For Vmux - the following indices are used:
1 for Transparent
2-3 for SS71-SS72 (respectively)
4-7 for Data1-Data4 (respectively)
8 for HDLC Ph2 Compatible
9-16 for Sub-CH1-1...Sub-CH1-8 (respectively)."
::= { dsx1DataStreamStatEntry 2 }
dsx1DataStreamStatValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether this Data Stream is valid or not.
When invalid - all counters are irrelevant."
::= { dsx1DataStreamStatEntry 3 }
dsx1DataStreamStatInFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames,
encountered by the DS1 Data Stream."
::= { dsx1DataStreamStatEntry 4 }
dsx1DataStreamStatInBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received bytes,
encountered by the DS1 Data Stream."
::= { dsx1DataStreamStatEntry 5 }
dsx1DataStreamStatInDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Discarded incoming frames,
encountered by the DS1 Data Stream."
::= { dsx1DataStreamStatEntry 6 }
dsx1DataStreamStatInErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received Errored frames,
encountered by the DS1 Data Stream."
::= { dsx1DataStreamStatEntry 7 }
dsx1DataStreamStatOutFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted frames,
encountered by the DS1 Data Stream."
::= { dsx1DataStreamStatEntry 8 }
dsx1DataStreamStatOutBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted bytes,
encountered by the DS1 Data Stream."
::= { dsx1DataStreamStatEntry 9 }
dsx1DataStreamStatOutDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Discarded outgoing frames,
encountered by the DS1 Data Stream."
::= { dsx1DataStreamStatEntry 10 }
dsx1DataStreamStatOutErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of errored transmitted frames,
encountered by the DS1 Data Stream."
::= { dsx1DataStreamStatEntry 11 }
-- Extension to the DS1 Configuration Table
dsx1XConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx1XConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An extension to the DS1 Configuration table."
::= { ds1Interface 2 }
dsx1XConfigEntry OBJECT-TYPE
SYNTAX Dsx1XConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing additional configuration
parameters."
-- AUGMENTS { dsx1ConfigTable }
INDEX { dsx1LineIndex }
::= { dsx1XConfigTable 1 }
Dsx1XConfigEntry ::=
SEQUENCE {
dsx1IdleCode Integer32,
dsx1LineMode INTEGER,
dsx1dBTxGain INTEGER,
dsx1RxSensitivity INTEGER,
dsx1RestoreTime INTEGER,
dsx1TcFirstSignal Integer32,
dsx1TcSignal Integer32,
dsx1TcPattern Integer32,
dsx1Scramble INTEGER,
dsx1LineAdaptiveTimingMode INTEGER,
dsx1TxClockSource INTEGER,
dsx1AisEnable INTEGER,
dsx1TsEchoCancel OCTET STRING,
dsx1EchoCancelerModule INTEGER,
dsx1PortFunction INTEGER,
dsx1PortMultiplier INTEGER,
dsx1LeasedLine INTEGER,
dsx1CsuLoop INTEGER,
dsx1ClockSource Integer32,
dsx1OosSignal INTEGER,
dsx1BundleNextIndex Integer32,
dsx1CRC6CalcMode INTEGER,
dsx1SendUponFail INTEGER
}
dsx1IdleCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Byte pattern of the data received/transmitted in the
E1T1 framer idle timeslots.
Valid range: (0 - FF HEX)."
::= { dsx1XConfigEntry 1 }
dsx1LineMode OBJECT-TYPE
SYNTAX INTEGER {
csu(1),
dsu(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"T1 device operation mode.
Valid for T1 only."
::= { dsx1XConfigEntry 2 }
dsx1dBTxGain OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
neg75dB (2),
neg15dB (3),
neg225dB (4),
zerodB (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transmit line Gain for T1 CSU line mode."
::= { dsx1XConfigEntry 3 }
dsx1RxSensitivity OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
longHaul (2),
shortHaul (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low Sensitivity is considered Short Haul while High Sensitivity
is considered Long Haul. The actual values depend on the LIU.
Examples:
- E1: -12dB is considered Short Haul ; -43dB is considered Long Haul
- T1: -12dB is considered Short Haul ; -36dB is considered Long Haul."
::= { dsx1XConfigEntry 4 }
dsx1RestoreTime OBJECT-TYPE
SYNTAX INTEGER {
other(1),
sec1(2),
sec10(3),
immediate(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to change the sync. algorithms to reduce the time
required for the port to return to normal operation after
a RED alarm.
'sec1' = Fast,
'sec10' = TR-6211,
'immediate' = CCITT"
::= { dsx1XConfigEntry 5 }
dsx1TcFirstSignal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trunk conditioning signal - value to be sent as a signal
during the first 2.5 seconds after alarm detection.
Range is 0x0..0xF. 0xFF is a NULL value.
This variable is used also for Space Signaling Code (in this case
0xFF is not NULL)."
::= { dsx1XConfigEntry 6 }
dsx1TcSignal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trunk conditioning signal value after alarm detection.
Range is 0x1..0xF for E1, and 0x0..0xF for T1.
This variable is used also for Space Signaling Code (E1 and T1)."
::= { dsx1XConfigEntry 7 }
dsx1TcPattern OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trunk conditioning data pattern to be sent upon a DS0 fail.
Range is 0x0..0xFF.
This variable used also for Out of Service Code."
::= { dsx1XConfigEntry 8 }
dsx1Scramble OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
notActive (2),
active (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Scrambling is an operation that randomizes the bits
of the payload of the ATM cell by a polynom.
This operation helps with the error detection mechanism
of the HEC. Not applicable for E1.
active - will scramble/descramble the payload ATM cell
notActive - will not scramble/descramble. "
::= { dsx1XConfigEntry 9 }
dsx1LineAdaptiveTimingMode OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables end to end clock synchronization.
Default value - off."
::= { dsx1XConfigEntry 10 }
dsx1TxClockSource OBJECT-TYPE
SYNTAX INTEGER {
loopTiming(1),
localTiming(2),
throughTiming(3),
adaptive(4),
system(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The source of Transmit Clock.
'loopTiming' indicates that the recovered receive clock
is used as the transmit clock.
'localTiming' indicates that a local clock
source is used or when an external clock is
attached to the box containing the interface.
'throughTiming' indicates that recovered receive clock
from another interface is used as the transmit clock.
'adaptive' indicates that the clock is recovered according
to the received data flow rate.
'system' indicates that the system clock
is used as the transmit clock."
::= { dsx1XConfigEntry 11 }
dsx1AisEnable OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
disable(2),
enable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/ disable AIS transmit when Ethernet cable (for TDMoIP) is out (disconnected)."
::= { dsx1XConfigEntry 12 }
dsx1TsEchoCancel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines for each TS whether Echo-Cancellation is on.
Each bit represents one TS as follow:
First octet bit'0' = TS#1, bit'7' = TS#8, .. 2nd octet bit'0' = TS#9,..,
4th octet bit'7' = TS#32.
Octets and bits order is from left to right:
[31,30,..24] [23..16] [15..8] [7..0]
MSB LSB MSB LSB MSB LSB MSB LSB
For each bit values are:
0 - Echo-Cancellation off.
1 - Echo-Cancellation on."
::= { dsx1XConfigEntry 13 }
dsx1EchoCancelerModule OBJECT-TYPE
SYNTAX INTEGER {
notExist(2),
exist(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates whether echo-cancellation module
exists for this line."
::= { dsx1XConfigEntry 14 }
dsx1PortFunction OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
uni (2),
ces (3),
ima (4),
cesPsn (5),
abis (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines the ATM Mode over the
physical port.
uni - The port will function as an ATM UNI.
ces - The port will function as a CES.
ima - The port will function as an IMA-ATM.
cesPsn - The port will function as a CES-PSN.
abis - The port will function as an Abis."
::= { dsx1XConfigEntry 15 }
dsx1PortMultiplier OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
r56 (2),
r64 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines the data rate of each TS
(Kbps units).
This parameter is applicable for T1 only."
::= { dsx1XConfigEntry 16 }
dsx1LeasedLine OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether Line mode is regular (non Leased Line mode)
or transparent (Leased Line mode)."
::= { dsx1XConfigEntry 17 }
dsx1CsuLoop OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
local (2),
transparent (3),
remote (4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines where the CSU loop will be done:
local - locally (by IPmux) towards the TDM device
transparent - transferred to Remote Device that will send it to its
connected TDM device.
remote - Remote Device will close the loop towards the Local Device."
::= { dsx1XConfigEntry 18 }
dsx1ClockSource OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry specifies the source from which the clock will be taken.
Refer to device specification for source Index"
::= { dsx1XConfigEntry 19 }
dsx1OosSignal OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
space (2),
mark (3),
spaceMark (4),
markSpace (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This parameter defines the value to be sent as a signal
after alarm detection:
'Space' = both A and B signaling bits are forced
to '0' during out-of-service periods.
'Mark' = both A and B signaling bits are forced
to '1' during out-of-service periods.
'spaceMark' = A and B bits are forced to '0' for
2.5 seconds; then they are switched to '1'
until out-of-service condition disappears.
'markSpace' = A and B bits are forced to '1' for
2.5 seconds; then they are switched to '0'
until out-of-service condition disappears.
- '0'= 0 for T1, 1 for E1, or user defined value for Space
- '1'= 1 for T1, 0 for E1, or user defined value for Mark."
::= { dsx1XConfigEntry 20 }
dsx1BundleNextIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates the Next free Bundle Index for this DS1 port."
::= { dsx1XConfigEntry 21 }
dsx1CRC6CalcMode OBJECT-TYPE
SYNTAX INTEGER {
jtG704 (1),
ituG704(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines the CRC6 Calculation mode.
jtG704 =JT-G704 = the Japanese standard
ituG704=ITU-G704 = the International standard
This parameter is applicable for J1 only."
::= { dsx1XConfigEntry 22 }
dsx1SendUponFail OBJECT-TYPE
SYNTAX INTEGER
{
oosCode (2),
ais (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines which notification will be sent to the other side
upon fail of another interface.
In Ipmux14 the notification is sent upon failure of the Ethernet link."
::= { dsx1XConfigEntry 23 }
--NOTIFICATIONs
-- ALARM TRAPS
-- USER E1 LOCAL MULTIFRAME ALARM
ds1LocalMultiframeAlarmTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates near end (Local) Loss of
Multiframe Alignment, of the user E1 interface."
::= { prtDS1Events 1 }
-- USER E1 REMOTE MULTIFRAME ALARM
ds1RemoteMultiframeAlarmTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates that the far end (remote) unit,
connected to the user E1 interface, reports
Loss of Multiframe Alignment."
::= { prtDS1Events 2 }
-- USER DS1 LINK FRAME SLIP
ds1LinkFrameSlipTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates that a Frame Slip occurred at the user
DS1 interface. This usually indicates timing problems
(incorrect selection of timing reference),
on the user DS1 link."
::= { prtDS1Events 3 }
-- USER DS1 BPV ERROR
ds1BpvErrorTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates a Bipolar Violation (BPV)
error has been detected at the user DS1 interface."
::= { prtDS1Events 4 }
-- USER DS1 EXCESSIVE BPV
ds1ExcessiveBpvTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates excessive number of
Bipolar Violation errors (BPV)
detected by the user DS1 interface"
::= { prtDS1Events 5 }
-- USER DS1 CRC-4 ERROR
ds1Crc4ErrorTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates that a frame with CRC-4 error has been
detected at the user DS1 interface."
::= { prtDS1Events 6 }
-- USER DS1 EXCESSIVE ERROR RATIO
ds1ExcessiveErrorRatioTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates that the error rate, detected
at the user DS1 interface, on the frame synchronization bits
is high, as defined by ITU-T Rec. G.732."
::= { prtDS1Events 7 }
-- USER DS1 REMOTE SYNC LOSS
ds1RemoteSyncLossTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates that the far-end (remote)
unit, connected to user DS1 interface,
reports Loss of Frame Alignment (Sync Loss)."
::= { prtDS1Events 8 }
-- USER DS1 LOCAL SYNC LOSS
ds1LocalSyncLossTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates near end (Local)
Loss of Frame Alignment failure (Sync Loss),
of the user DS1 interface"
::= { prtDS1Events 9 }
-- USER DS1 AIS SYNC LOSS
ds1AisSyncLossTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates near end (Local)
Loss of Frame Alignment (Sync Loss), caused by the reception
of AIS at the user DS1 interface."
::= { prtDS1Events 10 }
-- USER DS1 AIS
ds1AisTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates AIS being received
at the user DS1 interface."
::= { prtDS1Events 11 }
-- NETWORK REMOTE LOOP
ds1NetworkRemoteLoopTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates that a remote loopback
has been activated, on the local uplink interface."
::= { prtDS1Events 12 }
-- USER SIDE REMOTE LOOP
ds1RemoteLoopTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates that a remote loopback
has been activated, on the local user port."
::= { prtDS1Events 13 }
-- USER SIDE LOCAL LOOP
ds1LocalLoopTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates that a local loopback
has been activated on the user port."
::= { prtDS1Events 14 }
-- DS1 EXCESSIVE FRAME SLIP
ds1ExcessiveFrameSlipTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates that the number of Frame Slips
detected at the user DS1 interface, during the last minute
exceeds threshold. For LA-110, threshold value is 10.
This usually indicates timing problems
(incorrect selection of timing reference) on the user DS1."
::= { prtDS1Events 15 }
-- USER DS1 EXCESSIVE CRC 4 ERROR
ds1ExcessiveCrc4ErrorTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates that the error rate
detected on the CRC-4 bits at the
user DS1 interface, is high."
::= { prtDS1Events 16 }
-- USER E1 EXCESSIVE LOCAL MULTIFRAME ALARM
ds1ExcessiveLocalMfAlarmTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates that the number of local
Loss of Multiframe Alignment events, detected at
the user E1 interface during the last minute exceeds threshold.
For LA-110, threshold value is 10."
::= { prtDS1Events 17 }
-- USER E1 EXCESSIVE REMOTE MULTIFRAME ALARM
ds1ExcessiveRemoteMfAlarmTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates that the number of
Loss of multiframe alignment events reported
by the remote unit connected to the user
E1 interface during the last minute exceeds threshold.
For LA-110, threshold value is 10."
::= { prtDS1Events 18 }
-- USER DS1 EXCESSIVE REMOTE SYNC LOSS
ds1ExcessiveRemoteSyncLossTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates that the number of far end
(remote) Loss of Synchronization alarms,
reported by the user DS1 interface
during the last minute, exceeds threshold.
For LA-110, threshold value is 10."
::= { prtDS1Events 19 }
-- USER DS1 EXCESSIVE LOCAL SYNC LOSS
ds1ExcessiveLocalSyncLossTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates that the number of
Loss of local Synchronization alarms
reported by the user DS1 interface
during the last minute, exceeds threshold.
For LA-110, threshold value is 10."
::= { prtDS1Events 20 }
-- USER DS1 SIGNAL LOSS
ds1SignalLossTrap NOTIFICATION-TYPE
OBJECTS {alarmSeverity, alarmState, ifAlias}
STATUS current
DESCRIPTION
"This trap indicates Signal Loss.
(possible reason - cable disconnection. etc.)"
::= { prtDS1Events 21 }
--END
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\radds3.txt
--
-- RAD-DS3-MIB DEFINITIONS ::= BEGIN
--Title: RAD-DS3 MIB
--
-- Copyright 1993 RAD Data Communications, Ltd.
-- All Rights Reserved.
-- It is RAD's intent to encourage the widespread use of
-- this Specification in connection with the management of
-- RAD products. RAD grants vendors, end-users,
-- and other interested parties a non-exclusive license to
-- use this Specification in connection with the management
-- of RAD products.
-- This Specification is supplied "as is," and RAD makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.
-- IMPORTS
-- Gauge32 FROM SNMPv2-SMI
-- ifIndex FROM SNMPv2-TC
-- OBJECT-TYPE FROM SNMPv2-SMI
-- radWan FROM RAD-GEN-MIB;
-- RAD-DS3 MIB
--Title: RAD's DS3 INTERFACE MIB
--Version: 1.0
--Date: 13.10.96
--By: Yair Arian
--File: ds3.mib
--
--Last update: 12 May 08 by Yig'al Hachmon
ds3Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 3}
prtDs3PerfHistory OBJECT IDENTIFIER ::= {ds3Interface 1}
-- The DS3 Interface Table
prtSDs3IfTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtDs3IfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS3 interface table."
::= { prtDs3PerfHistory 1 }
prtDs3IfEntry OBJECT-TYPE
SYNTAX PrtDs3IfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS3 interface table."
INDEX { ifIndex }
::= { prtSDs3IfTable 1 }
PrtDs3IfEntry ::=
SEQUENCE {
prtDs3IfTimeElapsed
Integer32,
prtDs3IfValidIntervals
Integer32
}
prtDs3IfTimeElapsed OBJECT-TYPE
SYNTAX Integer32 (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since
the beginning of the near end current error-
measurement period."
::= { prtDs3IfEntry 1 }
prtDs3IfValidIntervals OBJECT-TYPE
SYNTAX Integer32 (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of previous near end intervals for
which valid data was collected. The value will be
96 unless the interface was brought online within
the last 24 hours, in which case the value will be
the number of complete 15 minute near end
intervals since the interface has been online."
::= { prtDs3IfEntry 2 }
-- The DS3 Current Table
-- The DS3 Current table contains various statistics being
-- collected for the current 15 minute interval.
prtDs3CurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtDs3CurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS3 Current table."
::= { prtDs3PerfHistory 2 }
prtDs3CurrentEntry OBJECT-TYPE
SYNTAX PrtDs3CurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS3 Current table."
INDEX { ifIndex }
::= { prtDs3CurrentTable 1 }
PrtDs3CurrentEntry ::=
SEQUENCE {
prtDs3CurrentLOS
Gauge32,
prtDs3CurrentOOF
Gauge32,
prtDs3CurrentLOC
Gauge32,
prtDs3CurrentAIS
Gauge32,
prtDs3CurrentRDI
Gauge32,
prtDs3CurrentUAS
Gauge32,
prtDs3CurrentBIP
Gauge32,
prtDs3CurrentFEBE
Gauge32,
prtDs3CurrentSLM
Gauge32,
prtDs3CurrentSES
Gauge32,
prtDs3CurrentES
Gauge32,
prtDs3CurrentBitParity
Gauge32,
prtDs3CurrentPlcpLOF
Gauge32,
prtDs3CurrentPlcpRAI
Gauge32,
prtDs3CurrentPlcpBIP
Gauge32,
prtDs3CurrentPlcpFEBE
Gauge32,
prtDs3CurrentBPV
Gauge32,
prtDs3CurrentLCE
Gauge32,
prtDs3CurrentStatus
OCTET STRING
}
prtDs3CurrentLOS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOS
seconds, encountered by a DS3 interface in
the current 15 minute interval."
::= { prtDs3CurrentEntry 1 }
prtDs3CurrentOOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of OOF
seconds, encountered by a DS3
interface in the current 15 minute interval."
::= { prtDs3CurrentEntry 2 }
prtDs3CurrentLOC OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOC
seconds, encountered by a DS3
interface in the current 15 minute interval."
::= { prtDs3CurrentEntry 3 }
prtDs3CurrentAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of AIS
seconds, encountered by a DS3
interface in the current 15 minute interval."
::= { prtDs3CurrentEntry 4 }
prtDs3CurrentRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of RDI
seconds, encountered by a DS3
interface."
::= { prtDs3CurrentEntry 5 }
prtDs3CurrentUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of UAS,
encountered by a SONET interface."
::= { prtDs3CurrentEntry 6 }
prtDs3CurrentBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
BIP errors, encountered by a DS3
interface in the current 15 minute interval."
::= { prtDs3CurrentEntry 7 }
prtDs3CurrentFEBE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
FEBE errors, encountered by a DS3
interface in the current 15 minute interval."
::= { prtDs3CurrentEntry 8 }
prtDs3CurrentSLM OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SLM
seconds, encountered by an E3 (only )
interface in the current 15 minute interval."
::= { prtDs3CurrentEntry 9 }
prtDs3CurrentSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SES
encountered by a E3
interface in the current 15 minute interval."
::= { prtDs3CurrentEntry 10 }
prtDs3CurrentES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The number of Errored Seconds, encountered by a
DS3 interface in the current 15 minute interval."
::= { prtDs3CurrentEntry 11 }
prtDs3CurrentBitParity OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bit Parity Error counter. Relevant to T3 only."
::= { prtDs3CurrentEntry 12 }
prtDs3CurrentPlcpLOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOF
seconds, encountered by a DS3
interface in one of the previous 96, individual 15
minute, intervals. This counter is relevant for plcpInternal(5)
or plcpExternal(6) configuration If frame types only."
::= { prtDs3CurrentEntry 13 }
prtDs3CurrentPlcpRAI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receiving Yellow/Remote Alarm Indication. This counter is
relevant for PLCP (external/internal) frame types only."
::= { prtDs3CurrentEntry 14 }
prtDs3CurrentPlcpBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The counter associated with the number of BIP errors,
encountered by a DS3 interface in the current 15 minute
interval. This counter is relevant for PLCP (external/internal)
frame types only."
::= { prtDs3CurrentEntry 15 }
prtDs3CurrentPlcpFEBE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The counter associated with the number of FEBE
errors, encountered by a DS3 interface in the current
15 minute interval. This counter is relevant for PLCP
(external/internal) frame types only."
::= { prtDs3CurrentEntry 16 }
prtDs3CurrentBPV OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Number of BPVs (Bi-Polar Violations) , encountered by a
DS3 interface in the current 15 minute interval.
This object is relevant only for Electrical Line
of Fomi-E3/T3."
::= { prtDs3CurrentEntry 17 }
prtDs3CurrentLCE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Number of LCE (Link Code Errors) encountered
by a DS3 interface in the current 15 minute interval.
This object is relevant only for Optical Links
of Fomi-E3/T3."
::= { prtDs3CurrentEntry 18 }
prtDs3CurrentStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statuses of the current interval:
0 - Valid.
1 - redundantLinkSwitch - the link has been switched
by a redundancy mechanism.
2 - discontinuity - module was partialy out.
4 - notValid - module is out."
::= { prtDs3CurrentEntry 19 }
-- The DS3 interface Interval
-- The DS3 Interval Table contains various statistics
-- collected by the Interface over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
prtDs3IntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtDs3IntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS3 Interval table."
::= { prtDs3PerfHistory 3 }
prtDs3IntervalEntry OBJECT-TYPE
SYNTAX PrtDs3IntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS3 Interval table."
INDEX { ifIndex, prtDs3IntervalNumber }
::= { prtDs3IntervalTable 1 }
PrtDs3IntervalEntry ::=
SEQUENCE {
prtDs3IntervalNumber
Integer32,
prtDs3IntervalLOS
Gauge32,
prtDs3IntervalOOF
Gauge32,
prtDs3IntervalLOC
Gauge32,
prtDs3IntervalAIS
Gauge32,
prtDs3IntervalRDI
Gauge32,
prtDs3IntervalUAS
Gauge32,
prtDs3IntervalBIP
Gauge32,
prtDs3IntervalFEBE
Gauge32,
prtDs3IntervalSLM
Gauge32,
prtDs3IntervalSES
Gauge32,
prtDs3IntervalES
Gauge32,
prtDs3IntervalBitParity
Gauge32,
prtDs3IntervalPlcpLOF
Gauge32,
prtDs3IntervalPlcpRAI
Gauge32,
prtDs3IntervalPlcpBIP
Gauge32,
prtDs3IntervalPlcpFEBE
Gauge32,
prtDs3IntervalBPV
Gauge32,
prtDs3IntervalLCE
Gauge32,
prtDs3IntervalStatus
OCTET STRING
}
prtDs3IntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { prtDs3IntervalEntry 1 }
prtDs3IntervalLOS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOS
seconds , encountered by a DS3 interface in
one of the previous 96, individual 15 minute,
intervals."
::= { prtDs3IntervalEntry 2 }
prtDs3IntervalOOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of OOF
seconds, encountered by a DS3
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtDs3IntervalEntry 3 }
prtDs3IntervalLOC OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOC
seconds, encountered by a DS3
interface in one of the previous 96,
individual 15 minute, intervals."
::= { prtDs3IntervalEntry 4 }
prtDs3IntervalAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of AIS
seconds, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtDs3IntervalEntry 5 }
prtDs3IntervalRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of RDI
seconds, encountered by a DS3
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtDs3IntervalEntry 6 }
prtDs3IntervalUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of UAS,
encountered by a DS3
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtDs3IntervalEntry 7 }
prtDs3IntervalBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
BIP errors, encountered by a DS3
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtDs3IntervalEntry 8 }
prtDs3IntervalFEBE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
FEBE errors, encountered by a DS3
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtDs3IntervalEntry 9 }
prtDs3IntervalSLM OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SLM
seconds, encountered by an E3
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtDs3IntervalEntry 10 }
prtDs3IntervalSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SES
encountered by a E3
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtDs3IntervalEntry 11 }
prtDs3IntervalES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The number of Errored Seconds, encountered by a
DS3 interface in one of the previous 96, individual 15
minute, intervals."
::= { prtDs3IntervalEntry 12 }
prtDs3IntervalBitParity OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bit Parity Error counter. Relevant to T3 only."
::= { prtDs3IntervalEntry 13 }
prtDs3IntervalPlcpLOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOF
seconds, encountered by a DS3
interface in one of the previous 96, individual 15
minute, intervals. This counter is relevant for plcpInternal(5)
or plcpExternal(6) configuration If frame types only."
::= { prtDs3IntervalEntry 14 }
prtDs3IntervalPlcpRAI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receiving Yellow/Remote Alarm Indication. This counter is
relevant for PLCP (external/internal) frame types only."
::= { prtDs3IntervalEntry 15 }
prtDs3IntervalPlcpBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The counter associated with the number of BIP errors,
encountered by a DS3 interface in the current 15 minute
interval. This counter is relevant for PLCP (external/internal)
frame types only."
::= { prtDs3IntervalEntry 16 }
prtDs3IntervalPlcpFEBE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The counter associated with the number of FEBE
errors, encountered by a DS3 interface in the current
15 minute interval. This counter is relevant for PLCP
(external/internal) frame types only."
::= { prtDs3IntervalEntry 17 }
prtDs3IntervalBPV OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Number of BPVs (Bi-Polar Violations) , encountered by a
DS3 interface in the specified 15 minute interval.
This object is relevant only for Electrical Line
of Fomi-E3/T3."
::= { prtDs3IntervalEntry 18 }
prtDs3IntervalLCE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Number of LCE (Link Code Errors) encountered
by a DS3 interface in the specified 15 minute interval.
This object is relevant only for Optical Links
of Fomi-E3/T3."
::= { prtDs3IntervalEntry 19 }
prtDs3IntervalStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statuses of the current interval:
0 - Valid.
1 - redundantLinkSwitch - the link has been switched
by a redundancy mechanism.
2 - discontinuity - module was partialy out.
4 - notValid - module is out."
::= { prtDs3IntervalEntry 20 }
-- the DS3 Total table
prtDs3TotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtDs3TotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A list of Total entries."
::= { prtDs3PerfHistory 4 }
prtDs3TotalEntry OBJECT-TYPE
SYNTAX PrtDs3TotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of Total table."
INDEX { ifIndex }
::= { prtDs3TotalTable 1 }
PrtDs3TotalEntry ::=
SEQUENCE {
prtDs3TotalUAS Gauge32,
prtDs3TotalBPV Gauge32,
prtDs3TotalLCE Gauge32,
prtDs3TotalSES Gauge32
}
prtDs3TotalUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of UASs (Unavailable Seconds) , encountered by a
DS3 interface in the previous 96 intervals.
Invalid 15 minute intervals count as 0."
::= { prtDs3TotalEntry 6 }
prtDs3TotalBPV OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of BPVs (Bi-Polar Violations) , encountered by a
DS3 interface in the previous 96 intervals.
Invalid 15 minute intervals count as 0."
::= { prtDs3TotalEntry 17 }
prtDs3TotalLCE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of LCE (Link Code Errors) encountered
by a DS3 interface in the previous 96 intervals.
Invalid 15 minute intervals count as 0."
::= { prtDs3TotalEntry 18 }
prtDs3TotalSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of SES (Severely Errored Seconds) encountered
by a DS3 interface in the previous 96 intervals.
Invalid 15 minute intervals count as 0."
::= { prtDs3TotalEntry 19 }
dsx3XConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx3XConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An extension to the DS3 Configuration table."
::= { ds3Interface 2 }
dsx3XConfigEntry OBJECT-TYPE
SYNTAX Dsx3XConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing additional configuration
parameters."
AUGMENTS { dsx3ConfigEntry }
-- INDEX {dsx3LineIndex }
::= { dsx3XConfigTable 1 }
Dsx3XConfigEntry ::=
SEQUENCE {
dsx3AisEnable INTEGER,
dsx3TxClockSource INTEGER
}
dsx3AisEnable OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
disable(2),
enable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/ disable AIS transmit when Ethernet (for TDMoIP) line is disconnected."
::= { dsx3XConfigEntry 1 }
dsx3TxClockSource OBJECT-TYPE
SYNTAX INTEGER {
loopTiming(1),
localTiming(2),
throughTiming(3),
system (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The source of Transmit Clock.
loopTiming indicates that the recovered receive
clock is used as the transmit clock.
localTiming indicates that a local clock source is
used or that an external clock is attached to the
box containing the interface.
throughTiming indicates that transmit clock is
derived from the recovered receive clock of
another DS3 interface.
'system' indicates that the system clock
is used as the transmit clock."
::= { dsx3XConfigEntry 2}
-- The DS3/E3 Mapping Table
dsx3MappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx3MappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS3/E3 mapping table associates DS3/E3 channels
with logical or physical interfaces.
For example, consider a DS3 device with 16 T1's and 1 VCG.
There are 28 logical/internal channels, numbered 1 through 28
but only 17 are actually connected.
We might describe the allocation of channels, in the dsx3MappingTable, as
follows:
dsx3MappingIfIndex.1. 1 = 1001 dsx3MappingIfIndex.1.15 = 1015
dsx3MappingIfIndex.1. 2 = 1002 dsx3MappingIfIndex.1.16 = 1016
dsx3MappingIfIndex.1. 3 = 1003 dsx3MappingIfIndex.1.17 = 1017
dsx3MappingIfIndex.1. 4 = 1004 dsx3MappingIfIndex.1.18 = 0
dsx3MappingIfIndex.1. 5 = 1005 dsx3MappingIfIndex.1.19 = 0
dsx3MappingIfIndex.1. 6 = 1006 dsx3MappingIfIndex.1.20 = 0
dsx3MappingIfIndex.1. 7 = 1007 dsx3MappingIfIndex.1.21 = 0
dsx3MappingIfIndex.1. 8 = 1008 dsx3MappingIfIndex.1.22 = 0
dsx3MappingIfIndex.1. 9 = 1009 dsx3MappingIfIndex.1.23 = 0
dsx3MappingIfIndex.1.10 = 1010 dsx3MappingIfIndex.1.24 = 0
dsx3MappingIfIndex.1.11 = 1011 dsx3MappingIfIndex.1.25 = 0
dsx3MappingIfIndex.1.12 = 1012 dsx3MappingIfIndex.1.26 = 0
dsx3MappingIfIndex.1.13 = 1013 dsx3MappingIfIndex.1.27 = 0
dsx3MappingIfIndex.1.14 = 1014 dsx3MappingIfIndex.1.28 = 0
Note that in the case above all channels are mapped to one T3 port with ifIndex = 1.
The Channels 1...28 are represented via the 2nd index.
The values of 1001...1016 are the T1 interface ifIndexes.
The value of 1017 is the ifIndex of the VCG.
Unconnected channels have a value of 0.
"
::= { ds3Interface 3 }
dsx3MappingEntry OBJECT-TYPE
SYNTAX Dsx3MappingEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"An entry in the DS3 mapping table."
INDEX { dsx3MappingDs3Index, dsx3MappingNumber }
::= { dsx3MappingTable 1 }
Dsx3MappingEntry ::=
SEQUENCE {
dsx3MappingDs3Index InterfaceIndex,
dsx3MappingNumber Unsigned32,
dsx3MappingIfIndex InterfaceIndex
}
dsx3MappingDs3Index OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index value which uniquely identifies the
DS3/E3 interface to which this entry is applicable.
This value is also equal to dsx3LineIndex used in dsx3ConfigEntry.
For RICi-16 this is the ifIndex of the T3 interface."
::= { dsx3MappingEntry 1 }
dsx3MappingNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The channel number for this entry.
For RICi-16 this is the channel number 1...28."
::= { dsx3MappingEntry 2 }
dsx3MappingIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An index value that uniquely identifies a logical or physical
interface mapped to a DS3/E3 channel.
If no interface is currently using a channel, the value should be zero.
If a single interface occupies more than one channel,
that ifIndex value will be found in multiple channels.
For RICi-16 this is the ifIndex of the T1 or VCG interface."
::= { dsx3MappingEntry 3 }
-- END
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\radima.txt
--
-- RAD-IMA-MIB DEFINITIONS ::= BEGIN
--Title: RAD-IMA MIB
--
-- Copyright 1998 RAD Data Communications, Ltd.
-- All Rights Reserved.
-- IMPORTS
-- OBJECT-TYPE FROM RFC-1212
-- radWan FROM RAD-GEN-MIB;
-- RAD-IMA MIB
--Title: RAD's IMA INTERFACE MIB
--Version: 1.0
--Date: 15.09.98
--By: Ilana Schvetz
--File: radima.mib
--Last update: 15-Nov-2007 by Shay Harari
radAtmIma OBJECT IDENTIFIER ::= {radAtm 5}
imaPrimaryClk OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
link1(2),
link2(3),
link3(4),
link4(5),
automatic(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock source to be transmitted to the user side,
where user module is in 'External' clock source."
::= { radAtmIma 1 }
-- An extension to the Link Table
imaXLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF ImaXLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The IMA Link Status and Configuration table.
This table contains additional objects for the link table."
::= { radAtmIma 2 }
imaXLinkEntry OBJECT-TYPE
SYNTAX ImaXLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the IMA Link table."
-- AUGMENTS { imaLinkTable }
INDEX { imaLinkIfIndex }
::= { imaXLinkTable 1 }
ImaXLinkEntry ::=
SEQUENCE {
imaLinkDirection INTEGER,
imaLinkItcLBClkSrc INTEGER,
imaLinkActivation INTEGER
}
imaLinkDirection OBJECT-TYPE
SYNTAX INTEGER {
rx(1),
tx(2),
both(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"the Link direction."
-- DEFAULT { both }
::= { imaXLinkEntry 1 }
imaLinkItcLBClkSrc OBJECT-TYPE
SYNTAX INTEGER {
link1(1),
link2(2),
link3(3),
link4(4),
internal (5),
external (6),
automatic(7),
loopback (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock source for the current Tx-line."
::= { imaXLinkEntry 2 }
imaLinkActivation OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
down(2),
up(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IMA Link activation at ATM layer."
::= { imaXLinkEntry 3 }
-- An extension to the Group Table
imaXGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF ImaXGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The IMA group Status and Configuration table.
This table contains additional objects for the Group table."
::= { radAtmIma 3 }
imaXGroupEntry OBJECT-TYPE
SYNTAX ImaXGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the IMA Group table."
-- AUGMENTS { imaGroupTable }
INDEX { imaGroupIndex }
::= { imaXGroupTable 1 }
ImaXGroupEntry ::=
SEQUENCE {
imaGroupVersion INTEGER,
imaGroupCtcTxClkSrc INTEGER,
imaGroupCtcTxClkSrcPort Integer32,
imaGroupRestart INTEGER,
imaGroupType INTEGER
}
imaGroupVersion OBJECT-TYPE
SYNTAX INTEGER {
ver10(1),
ver11(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IMA Version."
::= { imaXGroupEntry 1 }
imaGroupCtcTxClkSrc OBJECT-TYPE
SYNTAX INTEGER {
link1 (1),
link2 (2),
link3 (3),
link4 (4),
internal (5),
external (6),
automatic (7),
loopback (8),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The source of the transmitted, common, Clock Source.
Applicable if imaGroupNeTxClkMode=ctc(1).
Automatic - Dynamic source, taken from the currently reference link.
Internal - taken from the Internal clock on card.
Loopback - Looped back from one of the ports. In this case a specific
port should be selected for imaGroupCtcTxClkSrcPort parameter.
Link N - Clock will be looped from one of the links."
::= { imaXGroupEntry 2 }
imaGroupCtcTxClkSrcPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is valid only when imaGroupCtcTxClkSrc=loopback.
The value may be any port identifier."
::= { imaXGroupEntry 3 }
imaGroupRestart OBJECT-TYPE
SYNTAX INTEGER {
off (1),
on (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"off(1)- default state.
After on(2) operation ends, value should be automatically
set to off(1).
on(2) - restarts the IMA Group State Machine (GSM)
and the Rx\Tx Link State Machines (Rx/Tx LSM)."
::= { imaXGroupEntry 4 }
imaGroupType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
e1t1 (2),
shdsl (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines the Type of IMA Group
(which determines its Links Type)."
::= { imaXGroupEntry 5 }
-- IMA Traps
--NOTIFICATIONS
atmImaGroupStatusChangeTrap NOTIFICATION-TYPE
OBJECTS { imaGroupFailureStatus }
STATUS current
DESCRIPTION
"This trap indicates IMA Group status change."
::= { radSysAtmEvents 80 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\radhdlc.txt
--
-- RAD-HDLC-MIB DEFINITIONS ::= BEGIN
--Title: RAD-HDLC MIB
--
-- Copyright 1998 RAD Data Communications, Ltd.
-- All Rights Reserved.
--Title: RAD's HDLC MIB
--Version: 1.0
--Date: 15.09.98
--By: Ilana Schvetz
--File: radhdlc.mib
--
-- Last Update: 10-Aug-05 By Shay Harari
hdlcMibObjects OBJECT IDENTIFIER ::= {diverseIfWanGen 5}
hdlcTable OBJECT-TYPE
SYNTAX SEQUENCE OF HdlcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The HDLC configuration table."
::= { hdlcMibObjects 1 }
hdlcEntry OBJECT-TYPE
SYNTAX HdlcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the RAD HDLC Table."
INDEX { ifIndex }
::= { hdlcTable 1 }
HdlcEntry ::=
SEQUENCE {
hdlcProtocol INTEGER,
hdlcRateResolution INTEGER,
hdlcTxClockSource INTEGER,
hdlcTerminalMode INTEGER,
hdlcLoopbackState INTEGER,
hdlcTxClockPolarity INTEGER,
hdlcFlowControl INTEGER,
hdlcLineRate Integer32,
hdlcRxClockMode INTEGER,
hdlcLOF Gauge32,
hdlcRxClockPolarity INTEGER,
hdlcRateCompatibility INTEGER
}
hdlcProtocol OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
v35 (2),
x21 (3),
rs530 (4),
cisco (5),
lapd (6),
laps (7), -- x86
proprietary (8),
gfp (9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The HDLC protocol type
V35 - HDLC encapsulated over V35
X21 - HDLC encapsulated over X21
RS530 - HDLC encapsulated over RS530
cisco - Compatible to Cisco HDLC format.
lapd - LAPD over HDLC.
laps - LAPS over HDLC.
proprietary - HDLC Proprietary.
gfp - General Framing Protocol."
::= { hdlcEntry 1 }
hdlcRateResolution OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
nx56Kbps(2),
nx64Kbps(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The baud rate of the internal clock."
::= { hdlcEntry 2 }
hdlcTxClockSource OBJECT-TYPE
SYNTAX INTEGER {
internal(1),
external(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The baud rate of the internal clock."
::= { hdlcEntry 3 }
hdlcTerminalMode OBJECT-TYPE
SYNTAX INTEGER {
dce(1),
dte(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"."
::= { hdlcEntry 4 }
hdlcLoopbackState OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
internal(2),
external(3),
disable(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"internal - All data coming from the
network port is looped back
external - All data comming from the line is
looped back."
::= { hdlcEntry 5 }
hdlcTxClockPolarity OBJECT-TYPE
SYNTAX INTEGER {
normal (1),
inverse(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"normal - The transmitted data is sampled at the middle of bit time
inverse - The transmitted data is sampled at the end of the bit time
(high data rate/long cable)."
::= { hdlcEntry 6 }
hdlcFlowControl OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable the CTS/RTS flow control signals."
::= { hdlcEntry 7 }
hdlcLineRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The rate values for HDLC are n*56/64Kbps, where 1<=n<=32, 64, 128
and the following values: 1544, 3088, 6176.
The rate values for HSSI is nMbps, where 1<=n<=52."
::= { hdlcEntry 8 }
hdlcRxClockMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
internal (2),
external (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"."
::= { hdlcEntry 9 }
hdlcLOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of seconds the port is in Loss Of Frame state."
::= { hdlcEntry 10 }
hdlcRxClockPolarity OBJECT-TYPE
SYNTAX INTEGER {
normal (1),
inverse(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"normal - The received data is sampled at the middle of bit time
inverse - The received data is sampled at the end of the bit time
(high data rate/long cable)."
::= { hdlcEntry 11 }
hdlcRateCompatibility OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether limit the port HDLC rate according to the Far-End device.
For exaple: limit the HDLC rate from 4000 PPS and 3000 PPS."
::= { hdlcEntry 12 }
hdlcPerformance OBJECT IDENTIFIER ::= {hdlcMibObjects 2}
hdlcCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF HdlcCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The HDLC Current table."
::= { hdlcPerformance 1 }
hdlcCurrentEntry OBJECT-TYPE
SYNTAX HdlcCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the HDLC Current table."
INDEX { hdlcCurrentIfIndex }
::= { hdlcCurrentTable 1 }
HdlcCurrentEntry ::=
SEQUENCE {
hdlcCurrentIfIndex
Integer32,
hdlcCurrentStatus
OCTET STRING,
hdlcCurrentLOF
Gauge32,
hdlcCurrentInFrames
Gauge32,
hdlcCurrentInErrors
Gauge32,
hdlcCurrentOutFrames
Gauge32,
hdlcCurrentAbortedFrames
Gauge32,
hdlcCurrentLengthError
Gauge32
}
hdlcCurrentIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the HDLC interface.
It may be ifIndex."
::= { hdlcCurrentEntry 1 }
hdlcCurrentStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statuses of the current interval:
0 - Valid.
1 - redundantLinkSwitch - the link has been switched
by a redundancy mechanism.
2 - discontinuity - module was partialy out.
4 - notValid - module is out."
::= { hdlcCurrentEntry 2 }
hdlcCurrentLOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of seconds the
port is in Loss Of Frame state, encountered
by the HDLC interface in the current 15 minute interval."
::= { hdlcCurrentEntry 3 }
hdlcCurrentInFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames,
encountered by the HDLC interface in the current 15 minute
interval."
::= { hdlcCurrentEntry 4 }
hdlcCurrentInErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Errored received
frames, encountered by the HDLC interface in the current 15
minute interval."
::= { hdlcCurrentEntry 5 }
hdlcCurrentOutFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted frames,
encountered by the HDLC interface in the current 15 minute
interval."
::= { hdlcCurrentEntry 6 }
hdlcCurrentAbortedFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of frames, in which
at least seven consecutive '1'-s (Abort sequence) were
encountered by the HDLC interface in the current 15 minute
interval."
::= { hdlcCurrentEntry 7 }
hdlcCurrentLengthError OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames
with length error, encountered by the HDLC interface in the
current 15 minute interval."
::= { hdlcCurrentEntry 8 }
--Interval Table
hdlcIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF HdlcIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The HDLC Interval table."
::= { hdlcPerformance 2 }
hdlcIntervalEntry OBJECT-TYPE
SYNTAX HdlcIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the HDLC Interval table."
INDEX { hdlcIntervalIfIndex, hdlcIntervalNumber }
::= { hdlcIntervalTable 1 }
HdlcIntervalEntry ::=
SEQUENCE {
hdlcIntervalIfIndex
Integer32,
hdlcIntervalNumber
Integer32,
hdlcIntervalStatus
OCTET STRING,
hdlcIntervalLOF
Gauge32,
hdlcIntervalInFrames
Gauge32,
hdlcIntervalInErrors
Gauge32,
hdlcIntervalOutFrames
Gauge32,
hdlcIntervalAbortedFrames
Gauge32,
hdlcIntervalLengthError
Gauge32
}
hdlcIntervalIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the HDLC interface.
It may be ifIndex."
::= { hdlcIntervalEntry 1 }
hdlcIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals exist)."
::= { hdlcIntervalEntry 2 }
hdlcIntervalStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statuses of the current interval:
0 - Valid.
1 - redundantLinkSwitch - the link has been switched
by a redundancy mechanism.
2 - discontinuity - module was partialy out.
4 - notValid - module is out."
::= { hdlcIntervalEntry 3 }
hdlcIntervalLOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of seconds the
port is in Loss Of Frame state, encountered by an HDLC
interface in one of the previous 96, individual 15 minute,
intervals."
::= { hdlcIntervalEntry 4 }
hdlcIntervalInFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames,
encountered by the HDLC interface in one of the previous 96,
individual 15 minute, intervals."
::= { hdlcIntervalEntry 5 }
hdlcIntervalInErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Errored received
frames, encountered by the HDLC interface in one of the
previous 96, individual 15 minute, intervals."
::= { hdlcIntervalEntry 6 }
hdlcIntervalOutFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
frames, encountered by the HDLC interface in one of
the previous 96, individual 15 minute, intervals."
::= { hdlcIntervalEntry 7 }
hdlcIntervalAbortedFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of frames, in which
at least seven consecutive '1'-s (Abort sequence) were
encountered by the HDLC interface in one of the previous 96,
individual 15 minute, intervals."
::= { hdlcIntervalEntry 8 }
hdlcIntervalLengthError OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames
with length error, encountered by the HDLC interface in
one of the previous 96, individual 15 minute, intervals."
::= { hdlcIntervalEntry 9 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\sigmon.txt
--
--Version: 1.0
--Date: 2.02.99
--By: Ilana Schvetz
--File: sigmon.txt
--
--Last Update: Ilana Schvetz 19.12.99
radAtmSignalingMonitor OBJECT IDENTIFIER ::= {radAtm 6 }
smSVCOperState OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SVC monitoring operational state."
-- DEFVAL { disable }
::= { radAtmSignalingMonitor 1 }
smSVCAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SVC monitoring status."
-- DEFVAL { disable }
::= { radAtmSignalingMonitor 2 }
smILMIMode OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
keepAliveOnly (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ILMI operational Mode."
-- DEFVAL { disable }
::= { radAtmSignalingMonitor 3 }
smILMIStatus OBJECT-TYPE
SYNTAX INTEGER {
down (1),
up (2),
disable (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ILMI protocol status (VCC 0,16)."
::= { radAtmSignalingMonitor 4 }
smUNIVersion OBJECT-TYPE
SYNTAX INTEGER {
uni3-0(1),
uni3-1(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UNI version that is used by both sides."
-- DEFVAL { UNI3_1 }
::= { radAtmSignalingMonitor 5 }
smPolicing OBJECT-TYPE
SYNTAX INTEGER {
none(1),
police(2),
monitoring(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of the police action performed on
the cells transmitted from the user side to
the network side."
-- DEFVAL { none }
::= { radAtmSignalingMonitor 6 }
smSAALStatus OBJECT-TYPE
SYNTAX INTEGER {
down (1),
up (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signaling data link (VCC 0,5) status."
::= { radAtmSignalingMonitor 7 }
-- SM Counters
smOpenedSesssions OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of SVC sessions currently opened."
::= { radAtmSignalingMonitor 8 }
smUserRejectedSessions OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of sessions that the user side rejected
to open."
::= { radAtmSignalingMonitor 9 }
smNetworkRejectedSessions OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of sessions that the Network side rejected."
::= { radAtmSignalingMonitor 10 }
smHostRejectedSessions OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of sessions that the device rejected
to open."
::= { radAtmSignalingMonitor 11 }
smVclILMISessionVpi OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ILMI Keep alive session VPI channel.
Default: 0. (VCI=16, fixed)."
::= { radAtmSignalingMonitor 12 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\sub_rtr.txt
--
-- version 5.25
-- file :sub_rtr.txt
--
--RTR-MIB
--
--Last update: 14-Aug-2008 by Shay Harari
--radRouter OBJECT IDENTIFIER ::= { rad 11 } RAD Router
-- ************************************************
-- Interfaces Group
-- Link Layer (layer 2) Configuration MIB
-- ************************************************
-- The following MIB group is used by the Management/Configuration
-- station to configure the device interfaces,
-- physicals as well as virtuals.
-- Each entry in the rtrDynamicIfConfigTable should have one of
-- the extended rtType.
-- It will also have a corresponding entry in the standard iftable.
-- The implementation uses these inputs to build the interface
-- layer of the device. The output is reflected in the
-- ifTable and ifStackTable which are implementation dependent.
rtrInterfaces OBJECT IDENTIFIER ::= { radRouter 1 }
RtrIfConfigTYPE ::= INTEGER
-- STATUS current
-- DESCRIPTION
-- "This type defines what type of sub-layer is used
-- in each entr of rtrDynamicIfConfigTable.
-- It should contain values from IANAifType
-- type for standard sub-layer, and values (starting from 999
-- decimal) for private sub-layers.
-- The values of the ifType field in ifTable should be taken
-- from IANAifType only."
{
other(1),
ethernetLan(6), -- From IANAifType
iso88023Csmacd(7),
tokenRingLan(9),
fddi(15),
basicISDN(20),
primaryISDN(21),
propPointToPoint(22), -- rndWAN
slip(28),
ppp(23), -- From IANAifType
frameRelay(32),
rs232(33),
atm(37),
x25ple(40),
v35(45),
fastEther(62), -- Fast Ethernet (100BaseT)
fastEtherFX(69), -- Fast Ethernet (100BaseFX)
virtualNet(500),
cod(1001), -- Rad/Rnd private
backUp(1002),
dialUp(1004),
b1isdn(1010),
b2isdn(1011),
ipBcst(1020),
ipPtp(1021),
ipxRaw(1022),
ipxEtType(1023),
ipxLlcSap(1024),
ipxLlcSnap(1025),
ipxPtp(1026),
brgUnder(1027),
wanDriver(1060),
ethernetDriver(1061),
tokenRingDriver(1062),
fddiDriver (1064), -- RAD private FDDI driver
virtualLan(1080),
unknown(1100)
}
rtrConfigIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrConfigIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of configured interfaces."
::= { rtrInterfaces 1 }
rtrConfigIfEntry OBJECT-TYPE
SYNTAX RtrConfigIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry defines a configured interface."
INDEX { rtrConfigIfIndex }
::= { rtrConfigIfTable 1 }
RtrConfigIfEntry ::= SEQUENCE {
rtrConfigIfIndex
InterfaceIndex,
rtrConfigIfType
RtrIfConfigTYPE,
rtrConfigIfName
DisplayString,
rtrConfigIfStatus
RowStatus
}
rtrConfigIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable uniquely identifies the interface.
It is used as a cross reference in other system tables"
::= { rtrConfigIfEntry 1 }
rtrConfigIfType OBJECT-TYPE
SYNTAX RtrIfConfigTYPE
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable identifies the type of the specific
entry in the rtrDynamicIfConfigTable.
This field is writable only at creation time
(i.e., when value of status is underCreation)."
::= { rtrConfigIfEntry 2 }
rtrConfigIfName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable provides a logical name to a specific entry in
rtrConfigIfTable. It is also used in identifying the Driver
interfaces."
::= { rtrConfigIfEntry 3 }
rtrConfigIfStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the ConfigEntry. The choices are those
defined in SNMPv2-TC. Only: active, createAndWait, and destroy
will be used.
active - The conceptual row is available for use by the managed device.
createAndWait - A new instance of a conceptual row is desired, but
not to have it available for use by the managed device.
destroy - Delete all instances associated with an existing conceptual row."
::= { rtrConfigIfEntry 4 }
-- Router Interface Configuration Table
rtrIfCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrIfCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Router Interface Configuration Table."
::= { rtrInterfaces 2 }
rtrIfCfgEntry OBJECT-TYPE
SYNTAX RtrIfCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Router Interface Configuration Table."
INDEX { rtrIfCfgIndex, rtrIfCfgIpAddress }
::= { rtrIfCfgTable 1 }
RtrIfCfgEntry ::= SEQUENCE {
rtrIfCfgIndex Integer32,
rtrIfCfgIpAddress IpAddress,
rtrIfCfgRowStatus RowStatus,
rtrIfCfgIpMask IpAddress,
rtrIfCfgIfIndex Integer32,
rtrIfCfgType INTEGER,
rtrIfCfgVlanId VlanIndex,
rtrIfCfgMtu Integer32,
rtrIfCfgName SnmpAdminString,
rtrIfCfgConnectionPointer RowPointer,
rtrIfCfgVlanTagging INTEGER,
rtrIfCfgVlanPriority Unsigned32,
rtrIfCfgParams Unsigned32,
rtrIfCfgMngAccess INTEGER,
rtrIfCfgLlcSnapEncaps INTEGER,
rtrIfCfgDhcp INTEGER
}
rtrIfCfgIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Router Interface Index.
(In some cases it will be equal to the Router Interface ifIndex)."
::= { rtrIfCfgEntry 1 }
rtrIfCfgIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP Address of the Router Interface."
::= { rtrIfCfgEntry 2 }
rtrIfCfgRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables the user to
create/delete entries of this table."
::= { rtrIfCfgEntry 3 }
rtrIfCfgIpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"IP Mask Address Router Interface."
::= { rtrIfCfgEntry 4 }
rtrIfCfgIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ifIndex of the device interface connected
to this Router Interface."
::= { rtrIfCfgEntry 5 }
rtrIfCfgType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
atm (2),
lis (3),
ethernet(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Router Interface Type.
atm - ATM router interface
lis - Logical IP Subnet router interface.
ethernet - Ethernet router interface. "
::= { rtrIfCfgEntry 6 }
rtrIfCfgVlanId OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The VLAN ID assigned to Tagged frames transmitted
from this Router Interface.
The value inserted should be a defined VLAN."
::= { rtrIfCfgEntry 7 }
rtrIfCfgMtu OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The size of the largest packet which can be sent/received
on the interface, specified in octets. For interfaces that
are used for transmitting network datagrams, this is the
size of the largest network datagram that can be sent on the
interface."
::= { rtrIfCfgEntry 8}
rtrIfCfgName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Router Interface Name."
::= { rtrIfCfgEntry 9 }
rtrIfCfgConnectionPointer OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter represents the entity that is connected
to this Router Interface.
The value of this parameter is a pointer to an existing row of a table,
where the entity connected to this Router Interface is defined.
Examples:
In case of an interface (from 2863.ifTable):
points to 'ifEntry' of corresponding row
= <ifEntry OID>.<ifIndex>
In case of a VPI/VCI (from 2515.atmVclTable):
points to 'atmVclEntry' of corresponding row
= <atmVclEntry OID>.<ATM>.VPI.VCI
In case of a Pseudo-Wire (from pwTable):
points to 'pwEntry' of corresponding row
= <pwEntry OID>.<pwIndex>
."
::= { rtrIfCfgEntry 10 }
rtrIfCfgVlanTagging OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
untag (2),
tag (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The VLAN Tagging."
::= { rtrIfCfgEntry 11 }
rtrIfCfgVlanPriority OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The VLAN Priority."
::= { rtrIfCfgEntry 12 }
rtrIfCfgParams OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents one or more parameters of the Router Interface.
Each group of bits (one or more bits) represents a specific parameter
and its possible values.
This object's mapping and interpretation will be specified in each
device's specification documents."
::= { rtrIfCfgEntry 13 }
rtrIfCfgMngAccess OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents whether Management Access is enabled
via this Router Interface."
::= { rtrIfCfgEntry 14 }
rtrIfCfgLlcSnapEncaps OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
bridgedPdu (2),
routedPdu (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the LLC/SNAP Encapsulation."
::= { rtrIfCfgEntry 15 }
rtrIfCfgDhcp OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates whether DHCP is enabled for this Router Interface."
::= { rtrIfCfgEntry 16 }
-- **************** Interfaces Groups End *******************
-- **************** IP Groups ******************
-- IP Group
-- ************************************************
-- IP Interface Configuration MIB
-- ************************************************
ipSpec OBJECT IDENTIFIER ::= { radRouter 2 }
rtrIpAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrIpAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is parralel to MIB II IpAddrTable, and is used to
add/delete entries to/from that table. In addition it contains
private objects."
::= { ipSpec 1 }
rtrIpAddrEntry OBJECT-TYPE
SYNTAX RtrIpAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The addressing information for one of this
entity's IP addresses."
INDEX {rtrIpAdEntAddr}
::= { rtrIpAddrTable 1 }
RtrIpAddrEntry ::= SEQUENCE {
rtrIpAdEntAddr IpAddress,
rtrIpAdEntIfIndex Integer32,
rtrIpAdEntNetMask IpAddress,
rtrIpAdEntForwardIpBroadcast INTEGER,
rtrIpAdEntBackupAddr IpAddress,
rtrIpAdEntStatus RowStatus
}
rtrIpAdEntAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address to which this entry's addressing
information pertains."
::= { rtrIpAddrEntry 1 }
rtrIpAdEntIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The index value which uniquely identifies the
interface to which this entry is applicable. The
interface identified by a particular value of this
index is the same interface as identified by the
same value of ifIndex."
::= { rtrIpAddrEntry 2 }
rtrIpAdEntNetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The subnet mask associated with the IP address of
this entry. The value of the mask is an IP
address with all the network bits set to 1 and all
the hosts bits set to 0."
::= { rtrIpAddrEntry 3 }
rtrIpAdEntForwardIpBroadcast OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" This variable controls forwarding of IP (sub)net-directed
broadcasts destined for an attached sub(net). "
DEFVAL { enable }
::= { rtrIpAddrEntry 4 }
rtrIpAdEntBackupAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" "
::= { rtrIpAddrEntry 5 }
rtrIpAdEntStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" The Status variable is used to create and destroy a Ip Addresses."
::= { rtrIpAddrEntry 6 }
icmpSpec OBJECT IDENTIFIER ::= { ipSpec 2 }
rtrIcmpGenErrMsgEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable controlls the ability to generate ICMP error messages"
DEFVAL { enable }
::= { icmpSpec 1 }
rtrIcmpRdTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrIcmpRdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains ICMP Router Discovery parameters
configurated per IP interface."
::= {icmpSpec 2}
rtrIcmpRdEntry OBJECT-TYPE
SYNTAX RtrIcmpRdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ICMP parameters configurated for IP interface."
INDEX {rtrIcmpRdIpAddr}
::= {rtrIcmpRdTable 1}
RtrIcmpRdEntry ::= SEQUENCE {
rtrIcmpRdIpAddr IpAddress,
rtrIcmpRdIpAdvertAddr IpAddress,
rtrIcmpRdMaxAdvertInterval Integer32,
rtrIcmpRdMinAdvertInterval Integer32,
rtrIcmpRdAdvertLifetime Integer32,
rtrIcmpRdAdvertise INTEGER,
rtrIcmpRdPreferenceLevel Integer32,
rtrIcmpRdEntStatus Integer32
}
rtrIcmpRdIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address to which this entry's information pertains."
::= {rtrIcmpRdEntry 1}
rtrIcmpRdIpAdvertAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The IP destination address to be used for multicast
Router Advertisements sent from the interface. The
only permissible values are the all-systems multicast
address, 224.0.0.1, or the limited-broadcast address,
255.255.255.255."
-- DEFVAL {224.0.0.1}
::= {rtrIcmpRdEntry 2}
rtrIcmpRdMaxAdvertInterval OBJECT-TYPE
SYNTAX Integer32 (4..1800)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time allowed between sending multicast
Router Advertisements from the interface, in seconds.
Must be no less than 4 seconds and no greater than 1800
seconds."
DEFVAL {600}
::= {rtrIcmpRdEntry 3}
rtrIcmpRdMinAdvertInterval OBJECT-TYPE
SYNTAX Integer32 (3..1800)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The minimum time allowed between sending unsolicited
multicast Router Advertisements from the interface, in
seconds. Must be no less than 3 seconds and no greater
than rtrIcmpRdMaxAdvertInterval.
Default: 0.75 * rtrIcmpRdMaxAdvertInterval."
::= {rtrIcmpRdEntry 4}
rtrIcmpRdAdvertLifetime OBJECT-TYPE
SYNTAX Integer32 (4..9000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum length of time that the advertised addresses
are to be considered as valid. Must be no less than
rtrIcmpRdMaxAdvertInterval and no greater than 9000 seconds.
Default: 3 * rtrIcmpRdMaxAdvertInterval."
::= {rtrIcmpRdEntry 5}
rtrIcmpRdAdvertise OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A flag indicating whether or not the address is to be
advertised."
DEFVAL {enable}
::= {rtrIcmpRdEntry 6}
rtrIcmpRdPreferenceLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The preferability of the address as a default router
address, relative to other router addresses on the same
subnet."
DEFVAL {0}
::= {rtrIcmpRdEntry 7}
rtrIcmpRdEntStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting of any value to this object set values of
all fields to the default values."
::= {rtrIcmpRdEntry 8}
rip2Spec OBJECT IDENTIFIER ::= { ipSpec 3 }
rtrRip2IfConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrRip2IfConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of rip2IfConfTable (RFC 1724 ,RIP 2).
It means that every time somebody creates/destroys a row in the
rip2IfConfTable, the same row should be automatically created/destroyed
in this table."
::= { rip2Spec 1 }
rtrRip2IfConfEntry OBJECT-TYPE
SYNTAX RtrRip2IfConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table rtrRip2IfConfTable."
INDEX { rtrRip2IfConfAddress }
::= { rtrRip2IfConfTable 1 }
RtrRip2IfConfEntry ::= SEQUENCE {
rtrRip2IfConfAddress IpAddress,
rtrRip2IfConfVirtualDis Integer32,
rtrRip2IfConfAutoSend INTEGER,
rtrRip2IfConfRipEnable INTEGER
}
rtrRip2IfConfAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The IP Address of this system on the indicated subnet.
For unnumbered interfaces, the value 0.0.0.N,
where the least significant 24 bits (N) is the ifIndex
for the IP Interface in network byte order "
::= { rtrRip2IfConfEntry 1 }
rtrRip2IfConfVirtualDis OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This variable defines the virtual number of hops assigned to
the interface specified by rtrIfIpAddrIndex. This enables
fine-tuning of the RIP routing algorithm."
DEFVAL { 1 }
::= { rtrRip2IfConfEntry 2 }
rtrRip2IfConfAutoSend OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"When set to enable only the default route is sent through
the interface. When set to disable, regular RIPs are sent."
DEFVAL { disable }
::= { rtrRip2IfConfEntry 3 }
rtrRip2IfConfRipEnable OBJECT-TYPE
SYNTAX INTEGER {
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object shows whether RIP Protocol is enabled on the current interface."
::= { rtrRip2IfConfEntry 4 }
arpSpec OBJECT IDENTIFIER ::= { ipSpec 4 }
rtrArpDeleteTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to any not-null value has the effect of deleting
all entries of the ARP table."
::= { arpSpec 1 }
rtrArpInactiveTimeOut OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable defines the maximum time period (in second) that can
pass between ARP requests concerning an entry in the ARP table.
After this time period, the entry is deleted from the table."
DEFVAL { 60000 }
::= { arpSpec 2 }
rtrArpProxy OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When ARP Proxy is enabled, the router can respond to
ARP requests for nodes located on a different sub-net,
provided they are it its network table. The router responds
with its own MAC address.
When ARP Proxy is disabled, the router responds only
to ARP requests for its own IP addresses."
DEFVAL { disable }
::= { arpSpec 3 }
-- ****************************************
-- NAT Network Address Translation
-- *****************************************
rtrNat OBJECT IDENTIFIER ::= { ipSpec 5 }
rtrNatIfConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrNatIfConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of interfaces which require separate NAT configuration."
::= {rtrNat 1}
rtrNatIfConfEntry OBJECT-TYPE
SYNTAX RtrNatIfConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A single routing domain in a single subnet."
INDEX { ifIndex, rtrNatIfVirtualAddress, rtrNatIfVirtualMask }
::= { rtrNatIfConfTable 1 }
RtrNatIfConfEntry ::=
SEQUENCE {
rtrNatIfVirtualAddress IpAddress,
rtrNatIfVirtualMask IpAddress,
rtrNatIfConfStatus RowStatus,
rtrNatIfRealAddress IpAddress,
rtrNatIfRealMask IpAddress,
rtrNatIfType INTEGER
}
rtrNatIfVirtualAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP Address of the virtual subnet to be translated by the 'NAT box'
attached to this interface.
For some devices/cases, it might represent the Virtual Lowest IP Address."
::= { rtrNatIfConfEntry 1 }
rtrNatIfVirtualMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The subnet Mask of the virtual subnet.
For some devices/cases, it might represent the Virtual Highest IP Address."
::= { rtrNatIfConfEntry 2 }
rtrNatIfConfStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Writing 'destroy' has the effect of deleting this interface."
::= { rtrNatIfConfEntry 3 }
rtrNatIfRealAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" The IP Address of the real subnet which is used by 'NAT box' for translation.
For some devices/cases, it might represent the Real Lowest IP Address."
::= { rtrNatIfConfEntry 4 }
rtrNatIfRealMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" The subnet Mask of the real subnet.
For some devices/cases, it might represent the Real Highest IP Address."
::= { rtrNatIfConfEntry 5 }
rtrNatIfType OBJECT-TYPE
SYNTAX INTEGER {
static (1),
dynamic (2),
pat (3),
transparent (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"NAT type.
static - Translate a specific virtual IP network to a specific real IP
network. TCP, UDP and ICMP sessions originated both in real and
virtual networks will be translated.
dynamic - (Concurrent) Translate real IP network to larger or equal virtual
IP network. TCP, UDP and ICMP sessions originated in virtual
networks only can be translated and sessions originated in real
networks will be rejected. A session that starts in the NAT system
will be active until there will be no traffic for aging timeout
period.
pat - (Port Address Translation/ Single IP).
Translate one real IP address to virtual IP network. TCP, UDP and
ICMP sessions originated in virtual network only can be translated,
sessions originated in real network will be rejected. A session
that starts in the NAT system will be active until there will be no
traffic for aging timeout period.
transparent - In transparent mode all frames belonging to the defined IP
network will be forwarded with no translation: virtual = real."
::= { rtrNatIfConfEntry 6 }
-- *************************************
-- Port Address Translation
-- *************************************
rtrPatTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrPatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Port Address Translation (PAT - single IP NAT) configuration Table."
::= {rtrNat 2}
rtrPatEntry OBJECT-TYPE
SYNTAX RtrPatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describe unique mapping between real IP address,
range of ports and protocol, to local (virtual) IP address.
Ports are used in the TCP (rfc793) to name the ends of logical
connections which carry long term conversations.
For the purpose of providing services to unknown callers,
a service contact port is defined. "
INDEX { rtrPatIdx }
::= { rtrPatTable 1 }
RtrPatEntry ::=
SEQUENCE {
rtrPatIdx Integer32,
rtrPatRealAddress IpAddress,
rtrPatVirtualAddress IpAddress,
rtrPatLowestPort Integer32,
rtrPatHighestPort Integer32,
rtrPatProtocol Integer32,
rtrPatStatus RowStatus
}
rtrPatIdx OBJECT-TYPE
SYNTAX Integer32 (1..30)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Running index for PAT table."
::= { rtrPatEntry 1 }
rtrPatRealAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The real IP Address used for translation "
::= { rtrPatEntry 2 }
rtrPatVirtualAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The virtual IP Address used for translation"
::= { rtrPatEntry 3 }
rtrPatLowestPort OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Lowest Port number for this PAT entry "
::= { rtrPatEntry 4 }
rtrPatHighestPort OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Highest Port number for this PAT entry "
::= { rtrPatEntry 5 }
rtrPatProtocol OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Protocol selected.
This Protocol and port range (lowest port - highest port)
define the application (FTP, Telnet, SMTP etc.).
Protocol enumaration numbers correspond to IP header 'protocol' field
(e.g. 6 means TCP, 17 means UDP)."
::= { rtrPatEntry 6 }
rtrPatStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables creating and deleting
entries of the table."
::= { rtrPatEntry 7 }
-- ************************************************
-- FACS MIB
-- ************************************************
rtrFACS OBJECT IDENTIFIER ::= { radRouter 5 }
rtrFACSDefaultAction OBJECT-TYPE
SYNTAX INTEGER {
block(1),
forward(2),
blockAndReport(129)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to define the default action for the device, when no
FACS statements applicable to a given frame are defined."
-- DEFVAL { 1 }
::= { rtrFACS 1 }
rtrFACSActTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrFACSActEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of FACS action."
::= { rtrFACS 2 }
rtrFACSActEntry OBJECT-TYPE
SYNTAX RtrFACSActEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each rtrFACSActEntry consist of the following parameters"
INDEX {rtrFACSActType,
rtrFACSActIfIndex}
::= { rtrFACSActTable 1 }
RtrFACSActEntry ::= SEQUENCE {
rtrFACSActType INTEGER,
rtrFACSActIfIndex Integer32,
rtrFACSAction INTEGER,
rtrFACSActiveDB INTEGER
}
rtrFACSActType OBJECT-TYPE
SYNTAX INTEGER {
tx(1),
rx(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates on which FACS Table the FACS
action will preform."
::= { rtrFACSActEntry 1 }
rtrFACSActIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface to which this FACS entry is applicable."
::= { rtrFACSActEntry 2 }
rtrFACSAction OBJECT-TYPE
SYNTAX INTEGER {
none(1),
eraseIP(2),
eraseDECnet(3),
eraseIPX(4),
eraseBrg(5),
replaceIP(6),
replaceIPX(8),
replaceBrg(9),
backupIP(10),
backupIPX(12),
backupBrg(13)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The management station that sends a SET request for one of these actions
with indexes rtrFACSType and rtrFACSIfIndex defines the type and the
interface Id for which all FACS statements are to be erased.
If no interface or no type is specified, all FACS statements for a
protocol are erased."
-- DEFVAL { 1 }
::= { rtrFACSActEntry 3 }
rtrFACSActiveDB OBJECT-TYPE
SYNTAX INTEGER {
active(1),
temporary(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter will point on which Facs DataBase the SNMP agent
read. The Active dataBase is Read Only. The user may change FACS
statements in the temporary DataBase and then write it to the
Active DB."
::= { rtrFACSActEntry 4}
rtrFACSTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrFACSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of FACS statment."
::= { rtrFACS 3 }
rtrFACSEntry OBJECT-TYPE
SYNTAX RtrFACSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each FACS statment consists of the following parameters"
INDEX {rtrFACSIfIndex,
rtrFACSProtocolType,
rtrFACSType,
rtrFACSIndex }
::= { rtrFACSTable 1 }
RtrFACSEntry ::= SEQUENCE {
rtrFACSIfIndex Integer32,
rtrFACSProtocolType INTEGER,
rtrFACSType INTEGER,
rtrFACSIndex Integer32,
rtrFACSSrcAdd OCTET STRING ,
rtrFACSSrcAddMask OCTET STRING,
rtrFACSDesAdd OCTET STRING,
rtrFACSDesAddMask OCTET STRING,
rtrFACSOperation INTEGER,
rtrFACSNetFiltering INTEGER,
rtrFACSSocketNum Integer32,
rtrFACSMask1Id Integer32,
rtrFACSMask2Id Integer32,
rtrFACSStatus INTEGER
}
rtrFACSIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface to which this FACS entry is applicable.
For applications this variables is always 0."
::= { rtrFACSEntry 1 }
rtrFACSProtocolType OBJECT-TYPE
SYNTAX INTEGER{
ip(1),
ipx(2),
dec(3),
bridge(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter define the protocol the Security Access Control
is applicable."
::= { rtrFACSEntry 2 }
rtrFACSType OBJECT-TYPE
SYNTAX INTEGER {
tx(1),
rx(2),
cod(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The Mode of in which this FACS statement operates.
For applications this variable is always rx(2)."
::= { rtrFACSEntry 3 }
rtrFACSIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index to the FACS Table. "
::= { rtrFACSEntry 4 }
rtrFACSSrcAdd OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The size of the octet string will be according to the protocol type
defined in rtrFACSProtocolType."
::= { rtrFACSEntry 5 }
rtrFACSSrcAddMask OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Source-address mask ."
::= { rtrFACSEntry 6 }
rtrFACSDesAdd OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination-address The size of the octet string will be according to the
protocol type define in rtrFACSProtocolType ."
::= { rtrFACSEntry 7 }
rtrFACSDesAddMask OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination-address mask ."
::= { rtrFACSEntry 8 }
rtrFACSOperation OBJECT-TYPE
SYNTAX INTEGER {
block(1),
forward(2),
permit(3), -- For Connect On demand Only
deny(4), -- For Connect On demand Only
blockAndReport(129)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"... ."
::= { rtrFACSEntry 9 }
rtrFACSNetFiltering OBJECT-TYPE
SYNTAX INTEGER {
none(1),
l2multicast(2), --applicable for Bridge protocol
arp(3), --applicable for ip protocol
icmp(4), --applicable for ip protocol
ip(5), --applicable for ip protocol
udp(6), --applicable for ip protocol
tcp(7), --applicable for ip protocol
decnet(8), --applicable for decnet protocol
ipx(9) --applicable for ipx protocol
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"... ."
::= { rtrFACSEntry 10 }
rtrFACSSocketNum OBJECT-TYPE --applicable for ip,ipx protocol
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port/socket number for different applications
0 is default meaning not applicable.
none(1),
ftp(21),
telnet(23),
smtp(25),
tftp(69),
snmp(161),
snmpTrap(162),
rip(520),
sapIPX(1106),
ripIPX(1107) "
::= { rtrFACSEntry 11}
rtrFACSMask1Id OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Index into RND mask table FACS/COD Type) ."
::= { rtrFACSEntry 12}
rtrFACSMask2Id OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Index into RND mask table FACS/COD according to
the value of rtrFACSType ."
::= { rtrFACSEntry 13}
rtrFACSStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4) -- logically deleted
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of a table entry."
::= { rtrFACSEntry 14}
rtrFACSFrameData OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..256))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Data from the frame that violated a FACS Filter."
::= { rtrFACS 4 }
-- **************** FACS Group Ends *******************
-- ************************************************
-- Bridge ports Configuration MIB
-- ************************************************
-- rtrBridge OBJECT IDENTIFIER ::= { radRouter 7 }
rtrBridgePortConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrBridgePortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of the bridge ports"
::= { rtrBridge 1 }
rtrBridgePortConfigEntry OBJECT-TYPE
SYNTAX RtrBridgePortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry defines a bridge port "
INDEX { rtrBridgePortCIndex }
::= { rtrBridgePortConfigTable 1 }
RtrBridgePortConfigEntry ::= SEQUENCE {
rtrBridgePortCIndex
Integer32,
rtrBridgePortCIf
Integer32,
rtrBridgePortCStatus
RowStatus
}
rtrBridgePortCIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the index of the bridge port. It is the same
as 'dot1dBasePort' of the Bridge MIB."
::= {rtrBridgePortConfigEntry 1}
rtrBridgePortCIf OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The config ifIndex the bridge port is sitting on. "
::= {rtrBridgePortConfigEntry 2}
rtrBridgePortCStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the RtrBridgePortConfigEntry.
Creating and destroying the bridge port is done by this
variable."
::= {rtrBridgePortConfigEntry 3}
radRouterConfig OBJECT IDENTIFIER ::= { radRouter 9 }
-- The Router's Configuration Table
rtrConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Router's Configuration table."
::= { radRouterConfig 1 }
rtrConfigEntry OBJECT-TYPE
SYNTAX RtrConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Router's Configuration table."
INDEX { rtrConfigIndex }
::= { rtrConfigTable 1 }
RtrConfigEntry ::=
SEQUENCE {
rtrConfigIndex Integer32,
rtrConfigDefaultGateway IpAddress,
rtrConfigArpAgingTime Integer32,
-- 4 is NOT used
rtrConfigClassifierTosMask Integer32,
rtrConfigRIPMode INTEGER
}
rtrConfigIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Router's Index."
::= { rtrConfigEntry 1 }
rtrConfigDefaultGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Router Default Gateway."
::= { rtrConfigEntry 2 }
rtrConfigArpAgingTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ARP Aging Time."
::= { rtrConfigEntry 3 }
-- { rtrConfigEntry 4 } is NOT used
rtrConfigClassifierTosMask OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Classifier's TOS Mask,
as follows:
0x1C for DTR -- rfc795
0x1E for Cisco
0xE0 for Precedence -- rfc795
0xFC for Diffserv
Else for Manual
."
::= { rtrConfigEntry 5 }
rtrConfigRIPMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
rip1(2),
rip2(3),
rip1And2(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines the Router Information Protocol
to measure the shortest path between 2 positions
on the network."
::= { rtrConfigEntry 6 }
rtrSystemAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the System Address."
::= { radRouterConfig 2 }
-- The Router's Forwarding Table
rtrFwdTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrFwdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Router's Forwarding Table."
::= { radRouterConfig 3 }
rtrFwdEntry OBJECT-TYPE
SYNTAX RtrFwdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Router's Forwarding table."
INDEX { rtrFwdIdx, rtrFwdIpAddress,
rtrFwdIpMask, rtrFwdRuleIdx }
::= { rtrFwdTable 1 }
RtrFwdEntry ::=
SEQUENCE {
rtrFwdIdx Integer32,
rtrFwdIpAddress IpAddress,
rtrFwdIpMask IpAddress,
rtrFwdRuleIdx Integer32,
rtrFwdRowStatus RowStatus,
rtrFwdNextHop IpAddress,
rtrFwdIfIndex Integer32,
rtrFwdType INTEGER,
rtrFwdProto INTEGER,
rtrFwdEthQueue Integer32,
rtrFwdMetric1 Integer32
}
rtrFwdIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Router Index."
::= { rtrFwdEntry 1 }
rtrFwdIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Destination IP Address."
::= { rtrFwdEntry 2 }
rtrFwdIpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Mask IP address."
::= { rtrFwdEntry 3 }
rtrFwdRuleIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Rule's Number."
::= { rtrFwdEntry 4 }
rtrFwdRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables the user to
create/delete entries in this table.
Entry of Type rtrFwdType = staticRouting(3)
are created by the user.
Only this type of entries can be deleted by the user.
Entry of Type rtrFwdType = interface(2)
are created/deleted automatically by the Agent
when the user creates/deletes an interface of the Router."
::= { rtrFwdEntry 5 }
rtrFwdNextHop OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the IP Address of the Next Hop."
::= { rtrFwdEntry 6 }
rtrFwdIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Interface Index."
::= { rtrFwdEntry 7 }
rtrFwdType OBJECT-TYPE
SYNTAX INTEGER {
other (1), -- not specified by this MIB
reject (2), -- route which discards traffic
local (3), -- local interface
remote (4) -- remote destination
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of route. Note that local(3) refers
to a route for which the next hop is the final
destination; remote(4) refers to a route for
which the next hop is not the final destina-
tion.
Routes which do not result in traffic forwarding or
rejection should not be displayed even if the
implementation keeps them stored internally.
reject (2) refers to a route which, if matched, discards
the message as unreachable. This is used in some
protocols as a means of correctly aggregating routes."
::= { rtrFwdEntry 8 }
rtrFwdProto OBJECT-TYPE
SYNTAX INTEGER {
other (1), -- not specified
local (2), -- local interface
netmgmt (3), -- static route
rip (8), -- Berkeley RIP or RIP-II
lis (41) -- Logical IP Subnet
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The routing mechanism via which this route was
learned. Inclusion of values for gateway routing
protocols is not intended to imply that
hosts should support those protocols."
::= { rtrFwdEntry 9 }
rtrFwdEthQueue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the ETH Queue number."
::= { rtrFwdEntry 10 }
rtrFwdMetric1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The primary routing metric for this route.
The semantics of this metric are determined by
the routing-protocol specified in the route's
rtrFwdProto value. If this metric is not
used, its value should be set to -1."
DEFVAL { -1 }
::= { rtrFwdEntry 11 }
rtrPbrTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrPbrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Router's Forwarding Table."
::= { radRouterConfig 4 }
rtrPbrEntry OBJECT-TYPE
SYNTAX RtrPbrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Router's Policy Based Routing (PBR) table."
INDEX { rtrPbrIdx,rtrPbrInterface, rtrPbrRuleIdx }
::= { rtrPbrTable 1 }
RtrPbrEntry ::=
SEQUENCE {
rtrPbrIdx Unsigned32,
rtrPbrInterface InterfaceIndex,
rtrPbrRuleIdx Unsigned32,
rtrPbrRowStatus RowStatus,
rtrPbrMatchAllFrames INTEGER,
rtrPbrSourceIpAddress IpAddress,
rtrPbrSourceIpMask IpAddress,
rtrPbrDestIpAddress IpAddress,
rtrPbrDestIpMask IpAddress,
rtrPbrIpProtocol Unsigned32,
rtrPbrMinFrameLength Unsigned32,
rtrPbrMaxFrameLength Unsigned32,
rtrPbrDiscardFrame INTEGER,
rtrPbrForwardingInterface InterfaceIndexOrZero,
rtrPbrNextHop IpAddress
}
rtrPbrIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Router Index."
::= { rtrPbrEntry 1 }
rtrPbrInterface OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Router interface for which this match-set
rule applies."
::= { rtrPbrEntry 2 }
rtrPbrRuleIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Policy Based Routing (PBR)
match-set rule index."
::= { rtrPbrEntry 3 }
rtrPbrRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables the user to
create/delete entries of this table."
::= { rtrPbrEntry 4 }
rtrPbrMatchAllFrames OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Forwarding decision is made regardless PBR Rule
(as if all conditions are matched)"
::= { rtrPbrEntry 5 }
rtrPbrSourceIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Received frame source IP Address."
::= { rtrPbrEntry 6 }
rtrPbrSourceIpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The subnet mask of the source IP Address."
::= { rtrPbrEntry 7 }
rtrPbrDestIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Received frame destination IP Address."
::= { rtrPbrEntry 8 }
rtrPbrDestIpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The subnet mask of the destination IP Address."
::= { rtrPbrEntry 9 }
rtrPbrIpProtocol OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Value of Protocol field in IP Frame header."
::= { rtrPbrEntry 10 }
rtrPbrMinFrameLength OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"."
::= { rtrPbrEntry 11 }
rtrPbrMaxFrameLength OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"."
::= { rtrPbrEntry 12 }
rtrPbrDiscardFrame OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Discard a frame when rule is matched ."
::= { rtrPbrEntry 13 }
rtrPbrForwardingInterface OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The router Interface through which the frame
should be forwarded, when rule is matched.
If there's no forwarding interface,
then this object has a value of zero"
::= { rtrPbrEntry 14 }
rtrPbrNextHop OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"IP Address of Next Hop, when Forwarding Interface is LAN,
or has BridgePDU (BVI) encapsulation."
::= { rtrPbrEntry 15 }
-- **************** Router Bridge Port Group Ends *******************
-- Traps
rtrFACSViolation NOTIFICATION-TYPE
OBJECTS { rtrFACSFrameData, rtrFACSProtocolType }
STATUS current
DESCRIPTION
"The trap is sent for every violation of a FACS filter."
::= { radSysRtrEvents 1 }
rtrSwDwnLoadTrap NOTIFICATION-TYPE
OBJECTS { fileName }
STATUS current
DESCRIPTION
"The trap is sent after the tftp download of the software
and before the decompression and reset operations."
::= { radSysRtrEvents 2 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\optimux2.txt
--
-- OPTIMUX-MIB DEFINITIONS ::= BEGIN
--Title: OPTIMUX MIB
--
-- Last Update : 19-2-2008 by Yig'al Hachmon
--
-- Copyright 1993 RAD Data Communications, Ltd.
-- All Rights Reserved.
-- It is RAD's intent to encourage the widespread use of
-- this Specification in connection with the management of
-- RAD products. RAD grants vendors, end-users,
-- and other interested parties a non-exclusive license to
-- use this Specification in connection with the management
-- of RAD products.
-- This Specification is supplied "as is," and RAD makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.
--IMPORTS
-- DisplayString FROM RFC1213-MIB
-- enterprises FROM RFC1155-SMI
-- OBJECT-TYPE FROM RFC-1212
-- TRAP-TYPE FROM RFC-1215
-- ifIndex, InterfaceIndex FROM IF-MIB
-- dsx1LoopbackStatus FROM DS1-MIB
-- dsx3LoopbackStatus FROM DS3-MIB;
-- radWan, agnIndication FROM RAD-GEN-MIB;
-- RAD-OPTIMUX MIB
--Title: RAD's OPTIMUX PRODUCT MIB
--Version: 2.0
--Date: 14/01/97
--By: Michele Hallak
--File: optimux2.txt
--
--rad OBJECT IDENTIFIER ::= { enterprises 164 }
--radWan OBJECT IDENTIFIER ::= { rad 3 } rad WAN Tree
--radGen OBJECT IDENTIFIER ::= { rad 6} General information
--Last update: 26-Oct-2006 by Orly Bachar
optimux OBJECT IDENTIFIER ::= { radWan 5 }
-- One Optimux is sometimes connected to another optimux (or other device)
-- via its link. Therefore, in some cases, the SNMP agent sitting on
-- one device is responsible of the second (remote)
-- device. This table supplies information for both
-- devices, while the first is the local one and the second
-- is the remote one.
optMxConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptMxConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains parameters of configuration
for each member of the couple of Optimux."
::= { optimux 1 }
optMxConfigEntry OBJECT-TYPE
SYNTAX OptMxConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Optimux Config table."
INDEX { optIndex }
::= { optMxConfigTable 1 }
OptMxConfigEntry ::=
SEQUENCE {
optIndex INTEGER,
optHWVersion DisplayString,
optSWVersion DisplayString,
optPSPrimary INTEGER,
optPSSecondary INTEGER,
optLinkActive InterfaceIndex,
optSelectLink INTEGER,
optGrpPayLoadLoop INTEGER,
optGrpClockSource INTEGER,
optRedundancyStatus INTEGER,
optRedundancyCnf INTEGER,
optFarEndType INTEGER,
optServiceChEnable INTEGER,
optMaskChAlr Integer32,
optAisEnable INTEGER,
optFarMng INTEGER,
optClockDivision INTEGER,
optDteLoopEnable INTEGER,
optGrpClockSourcePrt Integer32,
optIncomingAlarm INTEGER,
optDefChannelSet INTEGER,
optWaitToRestore Integer32,
optEnforcedLink INTEGER,
optFlipUponEvent Integer32,
optHwMaskChAlr Integer32,
optServiceChExist INTEGER,
optMaskSystemAlr INTEGER
}
optIndex OBJECT-TYPE
SYNTAX INTEGER {local(1), remote(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"optIndex = 1 is for local Optimux.
optIndex = 2 is for remote Optimux."
::= { optMxConfigEntry 1 }
optHWVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HW Version of the device."
::= { optMxConfigEntry 2 }
optSWVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SW Version of the device."
::= { optMxConfigEntry 3 }
optPSPrimary OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
fault(3),
active(4),
none(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the primary Power Supply Unit."
DEFVAL { active }
::= { optMxConfigEntry 4 }
optPSSecondary OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
fault(3),
active(4),
none(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the secondary Power Supply Unit."
DEFVAL { none }
::= { optMxConfigEntry 5 }
optLinkActive OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates which link is active.
For Optimux-4 it may be: 5, 6 or 105, 106
For FOMi-E3/T3 it may be: 51, 61 or 151, 161.
For Optimux-T3 it may be: 51 or 61.
For Optimux-155/1 refer to product spec."
::= { optMxConfigEntry 6 }
optSelectLink OBJECT-TYPE
SYNTAX INTEGER {
autoredundancy(1),
-- autoWoReturn(4), not in use for this version of Opt-4-C
main(5),
back(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used by Optimuxes.
- For Optimux 4E1/T1 Old Look:
This MIB object enables the user to force the device to use specific link.
autoredundancy= Main (Link 1) is the default link. When it will fail, the
device will use Backup (Link 2). If Main recovers, it
automatically returns to Main.
autoWoReturn = Automatic Without Return. Main (Link 1) is the default link.
When it will fail, the device will use Backup (Link 2).
If Main recovers, it will NOT return to Main. It will
continue using Backup.
This option is supported only by LRS cards.
main = Forces the device to start immediately use of Main (Link 1),
no matter what is its state and stay there. No Redundancy.
back = Forces the device to start immediately use of Backup (Link 2),
no matter what is its state and stay there. No Redundancy.
- For Optimux-T3, Optimux-155, Optimux-XL and OP-4 (New Look):
This MIB object is used to select which Link will be used as MAIN.
Therefore:
autoredundancy - not supported
main = Link A is MAIN (=default).
back = Link B is MAIN."
DEFVAL { autoredundancy }
::= { optMxConfigEntry 7 }
optGrpPayLoadLoop OBJECT-TYPE
SYNTAX INTEGER {
off(2), on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Performs payload loop ( remote loop) to 4 E1 channels
at once."
DEFVAL { off }
::= { optMxConfigEntry 8 }
optGrpClockSource OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
localInternal(2),
localExternal(3),
loopTiming(4),
transparent(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For Optimux XL:
If dsx3TransmitClockSource = localTiming(2), then the user
can configure this field as:
localInternal(2) = use the internal clock of the device
localExternal(3) = use the external clock connected to the port
dedicated to clock.
For FomiE3/T3 this object is always applicable.
localExternal(3) = station clock
transparent(5) = the device takes the clock info from the data.
For FomiE3/T3 with HSSI electrical interface, only the following
are valid: localInternal(2) and transparent(5).
For Optimux-T3 the applicable values are (2), (3), (4).
For Optimux-155/1 the applicable values are (2), (3), (4), (5)."
DEFVAL { notApplicable }
::= { optMxConfigEntry 9 }
optRedundancyStatus OBJECT-TYPE
SYNTAX INTEGER {
available(2), notAvailable(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If there are two modules 'links', then this field
should be set to available(2). If there is only one
module 'link', this field should be set to notAvailable(3)."
DEFVAL { available }
::= { optMxConfigEntry 10 }
optRedundancyCnf OBJECT-TYPE
SYNTAX INTEGER {
off(2),
auto(3),
manual(4),
forcedBU(6),
autoNonRevertive (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used by Optimux-XL, FomiE3/T3, Optimux-T3 and Optimux-155.
For Optimux-XL:
If optRedundancyStatus = notAvailable(3), then this field
can be off(2) or forcedBU(6).
- off(2) = forcedMain: forces the device to start immediately use of
Main (Link 1), no matter what is its state and stay there
- forcedBU(6) = forces the device to start immediately use of
Backup (Link 2), no matter what is its state and stay there.
This value is not supported by Optimux-T3.
Else, user can configure this field as:
auto(3) = switch back to main link when valid.
manual(4) = don't switch back to main link = automatic w/o return.
For FomiE3/T3 all values are applicable unconditioned.
For Optimux-T3 and OP-4 New Look, values off(2), auto(3), manual(4)
are applicable unconditioned.
For Optimux-155/1 values off (2) = Protection Lockout, auto (3) and manual (4)
and autoNonRevertive (7)"
DEFVAL { auto }
::= { optMxConfigEntry 11 }
optFarEndType OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
optimux4Sa (2),
optimux4Card(3),
fomiE3T3Sa (4),
fomiE3T3Card(5),
optimuxXL16 (6),
optimuxXLE1 (7),
optimux4E1L (8),
optimux4T1L (9),
optimuxXLT1 (10),
op16E1L (11), -- 19" box
op16E1LS (12), -- half 19" box (single)
opXLE1 (13), -- Optimux-XL New-Look
opXLT1 (14), -- Optimux-XL New-Look
opXL16E1 (15), -- Optimux-XL New-Look
op4E1 (16), -- Op-4E1 SA New-Look
op4T1 (17), -- Op-4T1 SA New-Look
fdsl101 (18),
fdsl201 (19),
op4E1LNew (20), --OP-4E1L - New Low Cost
op4T1LNew (21), --OP-4T1L - New Low Cost
op34E1 (22),
op4E1Mar06 (23), -- OP-4E1 R5
op4E1NG1 (24), -- OP-4E1 R6/R6.1
op4T1NG1 (25), -- OP-4T1 R7/R7.1
op25 (26),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Far-End type of product.
This object is especially relevant for the local optimux.
notApplicable - for devices that don't have a far-end unit."
::= { optMxConfigEntry 12 }
optServiceChEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Service Channel Enable/Disable for each Optimux (local/remote)."
::= { optMxConfigEntry 13 }
optMaskChAlr OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mask Channel Alarm.
This object is applicable only for Optimux cards.
The value of this object is a sum of 2**n, where n is a bit assigned to
a certain Channel. Bit='1' means masked.
For Optimux-4:
Bit0: CH1 ; Bit1: CH2 ; Bit2: CH3 ; Bit3: CH4 (Bit='1' means masked).
Examples:
- 15 : means that all Channels are masked.
- 9 : means that Alarms of CH 1 and CH 4 are masked.
For Optimux-T3:
Bit0: CH1 ; Bit1: CH2 ; Bit2: CH3 ;.. Bit20: CH21 OR Bit27: CH28.
For FDSL:
Bit0..Bit12 : CH1..CH12; Bit13: ETH ; Bit14..Bit15: Uplink1..Uplink2."
::= { optMxConfigEntry 14 }
optAisEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"AIS enable/disable.
notApplicable - for devices that do not support this feature."
::= { optMxConfigEntry 15 }
optFarMng OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used by Optimux-XL and FomiE3/T3.
Is there possibility of Far-End Management (no/yes).
This object is applicable only for the Local device.
notApplicable - for Remote device and devices that do not support it.
no - far-end device is NOT I-Type so it doesn't have a management
link to its pair-device.
yes - far-end device is I-Type so it has a management link to its
pair-device."
::= { optMxConfigEntry 16 }
optClockDivision OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
noDivision (2),
half (3),
quarter (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only for FomiE3/T3 having an HSSI Electrical
interface.
It gives the possibility of Clock Division, so that Clock Rate will
be less than T3/E3.
notApplicable - for a device that does not support it
noDivision - Clock stays as is (Internal or Transparent)
half - Clock will be half the original (divided by 2)
quarter - Clock will be a quarter of the original (divided by 4)."
::= { optMxConfigEntry 17 }
optDteLoopEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DTE Loop enable/disable (for example loop command requested
by router).
This object is applicable only for products having HSSI interface.
notApplicable - for devices that do not support this feature."
::= { optMxConfigEntry 18 }
optGrpClockSourcePrt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable for Optimux-T3, when optGrpClockSource=localExternal.
It enables the user to select the Channel or Station Clock from which
the Clock is received.
Valid values:
0 = notApplicable
1..28 (= CH1..CH28).
73 = Station Clock.
Only T1 Channels can be used as Clock Source.
For Optimux-155/1 refer to product spec for port indexing."
::= { optMxConfigEntry 19 }
optIncomingAlarm OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off(2),
on(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the Incoming Alarm (On/Off), via Alarm Relay connector.
This object is applicable only for Optimux-T3."
::= { optMxConfigEntry 20 }
optDefChannelSet OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
t1(2),
e1(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default configuration for all Optimux Channels: T1 or E1.
This object is applicable only for Optimux-T3."
::= { optMxConfigEntry 21 }
optWaitToRestore OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines the time (sec) device has to wait in the redundant
state until it goes back to the default Link."
::= { optMxConfigEntry 22 }
optEnforcedLink OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
noEnforcement(2),
main(3), -- Forced Switch
backup(4) -- Forced Switch
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is not applicable when optRedundancyCnf = off.
It enables user to enforce a Link in spite of the redundancy mechanism.
Selecting the noEnforcement(2) value cause return to the usual rules of the
redundancy mechanism.
main (3) and backup (4) are unconditional (force)."
::= { optMxConfigEntry 23 }
optFlipUponEvent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows user to define if Flip to the other port will
be performed (or not), for certain possible events.
Each event is represented by a bit. The value of the object is a sum
of 2**n, according to the bits having '1' value.
'1' - means that Flip should occur due to this event.
Bit 0 (LSB) = SD (Signal Degraded)."
::= { optMxConfigEntry 24 }
optHwMaskChAlr OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mask Channel Alarm done by the HW dip-switches.
This object is applicable only for Optimux cards.
The value of this object is a sum of 2**n, where n is a bit assigned to
a certain Channel.
For Optimux-16E1:
Bit0: CH1 ; Bit1: CH2 ; Bit2: CH3 ;.. Bit15: CH16 (Bit='1' means masked).
Examples:
- 9 : means that Alarms of CH 1 and CH 4 are masked."
::= { optMxConfigEntry 25}
optServiceChExist OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
notExist (2),
exist (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Service Channel Existence indication for each Optimux (local/remote)."
::= { optMxConfigEntry 26}
optMaskSystemAlr OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mask all system alarms for each Optimux (local/remote)."
::= {optMxConfigEntry 27}
-- This table is for XL Optimux, Optimux-T3, FOMi-E3/T3 SA, Optimux-155/1, Optimux 155 DS3
optMxModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptMxModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines the type of the module
enrolled in each slot."
::= { optimux 2 }
optMxModuleEntry OBJECT-TYPE
SYNTAX OptMxModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Optimux Module table."
INDEX { optMdIdx, optMdSltIdx }
::= { optMxModuleTable 1 }
OptMxModuleEntry ::=
SEQUENCE {
optMdIdx INTEGER,
optMdSltIdx Integer32,
optMdType INTEGER,
optMdHWVersion DisplayString,
optMdModLed OCTET STRING,
optMdWaveLength INTEGER,
optMdTimingMode INTEGER,
optMdStatusIndication Integer32
}
optMdIdx OBJECT-TYPE
SYNTAX INTEGER {local(1), remote(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" optMdIdx = 1 is for local Optimux.
optMdIdx = 2 is for remote Optimux."
::= { optMxModuleEntry 1 }
optMdSltIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For Optimux XL:
Slot A = 1, Slot B = 2, Slot C = 3, Slot D = 4,
Slot Link = 5, Slot BU = 6 .
For FomiE3/R3:
Slot of Station Clock = 3, Slot of Electrical Link = 4,
Slot of Optical Main Link = 5, Slot of Optical Backup Link = 6 .
For Optimux-T3:
Slot of Station Clock (internal card)= 3, Slot A = 5, Slot B = 6.
For Optimux-155/1:
E1/T1 Slot A - 1, E1/T1 Slot B- 2,
LINK-A - 5, LINK-B - 6
Fans moudle - 7
I/O-1 - 11, I/O-2 -12 ...I/O-6 - 16
For Optimux-155 DS3:
Common Logic+E3/T3 Slot A - 1, Common Logic+E3/T3 Slot B- 2, LINK-A - 5, LINK-B - 6"
::= { optMxModuleEntry 2 }
optMdType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
noModule(2),
e3linkCX34(3),
e3linkOPT1(4),
t3linkOPT1(5),
eth1Port(6),
e1FourUTP(7),
e1TwoPort(8),
e1TwoUB(9),
t1FourPort(10),
t1TwoPort(11),
e1FourRJ45(12), -- special for XL/16
e1FourBNC(13), -- special for XL/16
e1FourMiniBNC(14),
sfLink(15), -- single fiber
stationClk(16), -- for E1/E3 products only (not for XL/T1)
hssi(17),
stationClkT3(18), -- for FOMi-T3 and Optimux-T3 only
t3linkCX45(19), -- for FOMi-T3 and Optimux-T3 only
hs4(20), -- for HSM with 4 ports
hs2(21), -- for HSM with 2 ports
hs1(22), -- for HSM with 1 port
hs1x8M(23), -- for HSM with 1 port and 8M
fastEth(24), -- for fast ethernet with 1 port
nX64(25), -- for N x 64 E1 module
nX64AndUnbalanced2E1(26), -- N X 64 and unbalanced 2 E1 ports
nX64AndBalanced2E1(27), -- N X 64 and balanced 2 E1 ports
nX64T1(28),
nX64T1AndUnbalanced2T1(29), -- N X 64 T1 and unbalanced 2 T1 ports
nX64T1AndBalanced2T1(30), -- N X 64 T1 and balanced 2 T1 ports
ds1channels (31),-- E1/T1 ports of TELCO connector (Balanced)
op155Fiber (32),-- OP-155-1 & OP-155-3 Fiber link
op155SingleFiber(33),-- OP-155-1 Single Fiber Link
op155coax (34),-- OP-155-1 & OP-155-3 Coax Link
op63e1 (35),-- Optimux 155/1 63 E1 main access card
op84t1 (36),-- Optimux 155/1 84 T1 main access card
op155Ds3Cl (37),-- Optimux 155/3 Common Logic card with E3 or T3
ds1channelsUnbalanced (38), -- E1/T1 ports of TELCO connector (Unbalanced)
fastEthNew (39), -- for new HW fast ethernet with 1 port
op2128e1t1 (40), -- Optimux 155/1 21/28 E1/T1 main access card
op4256e1t1 (41), -- Optimux 155/1 42/56 E1/T1 main access card
fans (42), -- Optimux 155/1 fans module
t1FourRJ45 (43), -- OPTIMUX34 T1
e1Four2BNC (44) -- OPTIMUX34 2BNC E1
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module Type and number of connectors."
::= { optMxModuleEntry 3 }
optMdHWVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HW Version of the module."
::= { optMxModuleEntry 4 }
optMdModLed OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The meaning of each bit depends on the module type."
::= { optMxModuleEntry 5 }
optMdWaveLength OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
nm850(2),
nm1300(3),
nm1300Laser(4),
nm1550Laser(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wave Length of T3/E3 Optical Links in [nm] and specification if Laser or not."
::= { optMxModuleEntry 6 }
optMdTimingMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
internal(2),
external(3),
lbt(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Module Timing mode."
::= { optMxModuleEntry 7 }
optMdStatusIndication OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indication of Alarm and test status of
all interfaces served by a module.
For Optimux155, Each interface will be represented by 2
bits where the 1st bit (right) will specify alarm status
and the 2nd bit will specify test status.
e.g
00 - normal
01 - alarm active
11 - alarm active + testing
10 - testing
For bits assignment per interface refer to product spec."
::= { optMxModuleEntry 8 }
-- This table is for Optimux T3 that can be in a ring
optimuxRing OBJECT IDENTIFIER ::= {optimux 3}
optFramerPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptFramerPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines the connection of every ch of the framer."
::= {optimuxRing 1}
optFramerPortEntry OBJECT-TYPE
SYNTAX OptFramerPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Optimux Framer port Connections table."
INDEX { optFramerPortIdx }
::= { optFramerPortTable 1 }
OptFramerPortEntry ::=
SEQUENCE {
optFramerPortIdx Integer32,
optFramerPortConn Integer32,
optFramerPortType INTEGER,
optFramerPortFeIpAddr IpAddress
}
optFramerPortIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The channel of the Framer. Valid values:1..31."
::= { optFramerPortEntry 1 }
optFramerPortConn OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines the Framer channel connection.
The values will be as follows:
Loop(1),Ch1(2),Ch2(3)....,Ch28(29)."
::= { optFramerPortEntry 2 }
optFramerPortType OBJECT-TYPE
SYNTAX INTEGER{
notApplicable (1),
e1 (2),
t1 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines the Framer port (E1 or T1)."
::= { optFramerPortEntry 3 }
optFramerPortFeIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Address of the opposite optimux in the ring,which this channel connected to."
::= { optFramerPortEntry 4 }
optFramerConnChanges OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of changes in Framer connection table that occured
since last time there was a reset to this parameter"
::= {optimuxRing 2}
optRing OBJECT-TYPE
SYNTAX INTEGER {
pointToPoint(2),
ring(3),
drop(4),
radioRing(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indication about Optimux special behavior:
pointToPoint(2): regular operation mode (Point to Point).
ring(3): this optimux is part of a ring.
operations made on this device may affect other optimuxes in the Ring and vice versa.
drop(4): enables connection between T3 tributary channel and physical E1/T1 port.
In this mode there may be no connection between this Optimux and another Optimux
While working in this mode optimux CANNOT be in PTP or Ring topology.
radioRing(5): this optimux is part of a ring that may use one or more Radio Links.
Operations made on this device may affect other optimuxes in the Ring and vice versa."
::= {optimuxRing 3 }
optRingNeTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptRingNeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines which optimuxes are in the ring and the
IP Address of each one."
::= { optimuxRing 4}
optRingNeEntry OBJECT-TYPE
SYNTAX OptRingNeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Optimux Ring Connections table."
INDEX { optRingNeIdx }
::= { optRingNeTable 1 }
OptRingNeEntry ::=
SEQUENCE {
optRingNeIdx Integer32,
optRingNeIpAddr IpAddress
}
optRingNeIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the optimux, starting with next optimux to the current optimux.
Valid values:1..28.
The index is according to the order of optimux connections in the ring.
Example:
1=next optimux to the current, in the ring
2=next optimux in the ring, after the one having index=1
etc..
Last index will be the current optimux, that close the ring. "
::= { optRingNeEntry 1 }
optRingNeIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP Address of each optimux in the ring, according to optRingNeIdx."
::= { optRingNeEntry 2 }
optRingActiveMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
main (2),
backup (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates whether the Ring works in Main or Backup mode."
::= { optimuxRing 5}
-- Traps
--NOTIFICATIONS
optimuxEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for Optimux."
::= { optimux 0 }
optMxConfigChange NOTIFICATION-TYPE
OBJECTS {optIndex, agnLed }
STATUS current
DESCRIPTION
"The trap is sent every time there is a change in
the state of one of the PS.."
::= { optimuxEvents 1 }
optMxAgentFault NOTIFICATION-TYPE
OBJECTS {agnIndication, agnLed }
STATUS current
DESCRIPTION
"The trap is sent every time there is a change in
the agnIndication variable.
For Optimux XL family, from ver 4.1 and up, this trap should be sent
upon any change in the agnNearFarConnection variable"
::= { optimuxEvents 2 }
optLineStatusChange NOTIFICATION-TYPE
OBJECTS { dsx1LineStatus,
dsx1LineStatusLastChange }
STATUS current
DESCRIPTION
"optLineStatusChange trap is sent when the value of an instance
dsx1LineStatus changes. It can be utilized by an NMS to trigger polls.
When the line status change results from a higher level line status
change (i.e. ds3), then no traps for the ds1 are sent."
::= { optimuxEvents 3 }
optSlotChange NOTIFICATION-TYPE
OBJECTS { optMdIdx, optMdSltIdx }
STATUS current
DESCRIPTION
"This trap alerts the console if there is module
enrollement/de-enrollement"
::= { optimuxEvents 4 }
optLoopbackStatusChange NOTIFICATION-TYPE
OBJECTS { ifIndex, dsx1LoopbackStatus, dsx3LoopbackStatus }
STATUS current
DESCRIPTION
"This trap alerts the console if there is changes in the
loopback status of some of the line."
::= { optimuxEvents 5 }
optXlLineStatusChange NOTIFICATION-TYPE
OBJECTS { ifIndex, optMdModLed, dsx1LineStatus, dsx3LineStatus }
STATUS current
DESCRIPTION
"optXlLineStatusChange trap is sent when the value of an instance
dsx1LineStatus changes. It can be utilized by an NMS to trigger polls."
::= { optimuxEvents 6 }
optRingActiveModeChange NOTIFICATION-TYPE
OBJECTS { optRingActiveMode}
STATUS current
DESCRIPTION
"optRingActiveModeChange trap is sent when the value of
optRingActiveMode changes."
::= { optimuxEvents 7 }
optActiveLinkFlipTrap NOTIFICATION-TYPE
OBJECTS { optLinkActive }
STATUS current
DESCRIPTION
"The trap is sent upon change of Active link module."
::= { optimuxEvents 8 }
-- END
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\webrnger.txt
--
--Version: 1.0
--Date: 26.04.98
--By: Ilana Schvetz
--File: webranger.txt
--
--Last update: 14-Aug-2008 by Shay Harari
--radRouter OBJECT IDENTIFIER ::= { rad 11 }
--rtrBridge OBJECT IDENTIFIER ::= { radRouter 7 }
webranger OBJECT IDENTIFIER ::= { rtrBridge 2 }
wrSysConfig OBJECT IDENTIFIER ::= { webranger 1 }
wrBraodcastCtrlCmd OBJECT-TYPE
SYNTAX INTEGER {
block (1),
forward (2),
blockLinkPropagation (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is a command to the webranger CPU. It
enables blocking or forwarding broadcast frames, which
may cause a trigger to a connection.
block (1) - blocks the broadcast frames.
forward (2) - forwards the broadcast frames.
blockLinkPropagation (3) - blocks the broadcast frames to the links, tx
to the LAN. "
::= { wrSysConfig 1 }
wrFrSelfLearningMode OBJECT-TYPE
SYNTAX INTEGER {
off (1),
on (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter enables the webranger to learn the DLCi's
configuration and maintanance protocol.
off - will get the configuration by setting it.
on - disables configuration and start self learning."
::= { wrSysConfig 2 }
wrGratuitousArp OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter enables/disables the Gratuitous ARP feature.
When enabled, the feature means: when receiving ARP with sender's
Source IP Address that already exists in the ARP table - replace
MAC Address with sender's Source MAC Address."
::= { wrSysConfig 3 }
wrIpRouterInfo OBJECT IDENTIFIER ::= { webranger 2 }
wrConfigIpDhcp OBJECT IDENTIFIER ::= { wrIpRouterInfo 1 }
wrConfigIpDNS OBJECT IDENTIFIER ::= { wrIpRouterInfo 2 }
wrDhcpAction OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Activating (disable/enable) DHCP server operation.
Since DHCP Server and DHCP Relay cannot reside in same device,
DHCP Relay may be enabled (per interface), only if server action is disabled.
For some devices, this object is used in order to enable/disable
the DHCP Client. See device SDS."
::= { wrConfigIpDhcp 1 }
wrDhcpTable OBJECT-TYPE
SYNTAX SEQUENCE OF WrDhcpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of DHCP entries. The number of entries is up to
DHCP current entries, according to the WEBRANger model."
::= { wrConfigIpDhcp 2 }
wrDhcpEntry OBJECT-TYPE
SYNTAX WrDhcpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DHCP parameters per entry of the DHCP table."
INDEX { wrDhcpLowIpAddress }
::= { wrDhcpTable 1 }
WrDhcpEntry ::=
SEQUENCE {
wrDhcpLowIpAddress
IpAddress,
wrDhcpHighIpAddress
IpAddress,
wrDhcpIpMaskAddress
IpAddress,
wrDhcpDefaultGateway
IpAddress,
wrDhcpPrimaryDNS
IpAddress,
wrDhcpSecondaryDNS
IpAddress,
wrDhcpInterface
INTEGER,
wrDhcpRowStatus
RowStatus,
wrDhcpIpAddressLeaseTime
Integer32,
wrDhcpPoolName
SnmpAdminString,
wrDhcpTftpServerIp
IpAddress,
wrDhcpConfigFileName
SnmpAdminString
}
wrDhcpLowIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DHCP Low Ip Address."
::= { wrDhcpEntry 1 }
wrDhcpHighIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"DHCP High Ip Address."
::= { wrDhcpEntry 2 }
wrDhcpIpMaskAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"IP mask Address."
::= { wrDhcpEntry 3 }
wrDhcpDefaultGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Default Gateway's IP Address."
::= { wrDhcpEntry 4 }
wrDhcpPrimaryDNS OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Primary DNS."
::= { wrDhcpEntry 5 }
wrDhcpSecondaryDNS OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Secondary DNS."
::= { wrDhcpEntry 6 }
wrDhcpInterface OBJECT-TYPE
SYNTAX INTEGER {
all (1),
lan1 (2),
lan2(3),
anyLan(4),
wan (5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The IP addresse allocation is done according to the
interface type from which the DHCP request arrives."
::= { wrDhcpEntry 7 }
wrDhcpRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute allows to create/delete a row in this table.
For creating a row, the NMS should set
wrDhcpRowStatus.id = active(1).
For destroying a row, the NMS should set:
wrDhcpStatus.id = destroy(6).
Only rows with status active(1) are relevant.
The only possible supported RowStatus vaules are
active (1) and destroy (6)."
::= { wrDhcpEntry 8 }
wrDhcpIpAddressLeaseTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Allocated IP Address lease time in seconds.
A zero value specifies no time limitation."
::= { wrDhcpEntry 9 }
wrDhcpPoolName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (1..10))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"DHCP pool name - string with max length of 10 characters"
::= { wrDhcpEntry 10 }
wrDhcpTftpServerIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"DHCP pool - TFTP-server IP Address."
::= { wrDhcpEntry 11 }
wrDhcpConfigFileName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (1..50))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"TFTP-name of the configuration File Name for DHCP pool."
::= { wrDhcpEntry 12 }
-- DHCP (Dynamic Host Configuration Protocol) Pool Allocation Table
dhcpPoolAllocTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpPoolAllocEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of DHCP Pool Allocation entries.
Each entry (row) consist of a single IP Address belonging to DHCP pool
whose lowest IP address is dhcpPoolAllocLowIpAddress.
This IP address may be offered for leasing, or may already be
leased (in use) by Host it's MacAddress is dhcpPoolAllocMacAddress.
Time left for leasing period is indicated by dhcpPoolAllocTimeLeft.
All posible statuses of IP address are indicated and controlled
by dhcpPoolAllocFlags"
::= { wrConfigIpDhcp 3 }
dhcpPoolAllocEntry OBJECT-TYPE
SYNTAX DhcpPoolAllocEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DHCP Pool Allocation parameters per entry of the DHCP Pool Allocation table."
INDEX {dhcpPoolAllocLowIpAddress, dhcpPoolAllocLeasingIpAddress}
::= { dhcpPoolAllocTable 1 }
DhcpPoolAllocEntry ::=
SEQUENCE {
dhcpPoolAllocLowIpAddress
IpAddress,
dhcpPoolAllocLeasingIpAddress
IpAddress,
dhcpPoolAllocMacAddress
MacAddress,
dhcpPoolAllocTimeLeft
Integer32,
dhcpPoolAllocFlags
INTEGER,
dhcpPoolAllocFreeCmd
INTEGER
}
dhcpPoolAllocLowIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lowest IP address of this pool, value eqaul to wrDhcpLowIpAddress for
the pool."
::= { dhcpPoolAllocEntry 1 }
dhcpPoolAllocLeasingIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Single IP Address belonging to dhcp pool whose Lowest Ip Address is
dhcpPoolAllocLowIpAddress. This IP address may be offered for leasing
or may be leased by Host its MacAddress is dhcpPoolAllocMacAddress.
All posible statuses of IP address are indicated by dhcpPoolAllocFlags "
::= { dhcpPoolAllocEntry 2 }
dhcpPoolAllocMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC Address to which the IP address has been leased "
::= { dhcpPoolAllocEntry 3 }
dhcpPoolAllocTimeLeft OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP address leasing time left in seconds "
::= { dhcpPoolAllocEntry 4 }
dhcpPoolAllocFlags OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
free (2),
inUse (3),
offered (4),
forbidden (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"These flags indicates status of each IP address.
User may change value to free, via dhcpPoolAllocFreeCmd "
::= { dhcpPoolAllocEntry 5 }
dhcpPoolAllocFreeCmd OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to On (3), will enforce the agent to
Free this entry.
The Agent will change the value of this MIB object to off(2)
automatically, after performing the command.
Setting this object to off(2), will do nothing"
::= { dhcpPoolAllocEntry 6 }
--DHCP Relay Table
dhcpRelayTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpRelayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of DHCP relay entries."
::= { wrConfigIpDhcp 4 }
dhcpRelayEntry OBJECT-TYPE
SYNTAX DhcpRelayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DHCP Relay parameters per entry of the DHCP relay table."
INDEX { ifIndex }
::= { dhcpRelayTable 1 }
DhcpRelayEntry ::=
SEQUENCE {
dhcpRelayAction
INTEGER,
dhcpRelayServerIpAddress
IpAddress,
dhcpRelayMaxHop
Integer32
}
dhcpRelayAction OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to enable (3), will
enable DHCP Relay action for this interface
(Only if DHCP Server is disabled for device - wrDhcpAction=disable).
dhcpRelayServerIpAddressaddress should not be 0.0.0.0 when enable is set"
::= { dhcpRelayEntry 1 }
dhcpRelayServerIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DHCP Server IP Address."
::= { dhcpRelayEntry 2 }
dhcpRelayMaxHop OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum number of hops till DHCP Server.
upper limit is 16 hops"
DEFVAL {16}
::= { dhcpRelayEntry 3 }
wrDhcpPort OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
all (2),
outOfBand (3),
lan1 (4),
lan2 (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines the port that DHCP flow will be actiavted."
::= { wrConfigIpDhcp 5}
--DHCP Client Table
dhcpClientTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of DHCP client entries."
::= { wrConfigIpDhcp 6 }
dhcpClientEntry OBJECT-TYPE
SYNTAX DhcpClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DHCP Client parameters per entry of the DHCP Client table."
INDEX { ifIndex }
::= { dhcpClientTable 1 }
DhcpClientEntry ::=
SEQUENCE {
dhcpClientAction
INTEGER,
dhcpClientServerIpAddress
IpAddress,
dhcpClientLeaseExpirationTime
Integer32,
dhcpClientStatus
DisplayString
}
dhcpClientAction OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter default value is enable(3).
Setting this attribute to disable (2), will
disable DHCP Client action for this interface.
This parameter can be changed to disable (2) only
(it cannot be changed from disable to enable)."
::= { dhcpClientEntry 1 }
dhcpClientServerIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DHCP Server IP Address."
::= { dhcpClientEntry 2 }
dhcpClientLeaseExpirationTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter holds the time (in minutes) left until lease expiration."
::= { dhcpClientEntry 3 }
dhcpClientStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parametr displays the DHCP status."
::= { dhcpClientEntry 4 }
--DHCP Interface Client Table
dhcpIfClientTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpIfClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DHCP client entries for each Interface."
::= { wrConfigIpDhcp 7 }
dhcpIfClientEntry OBJECT-TYPE
SYNTAX DhcpIfClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DHCP Clients per entry of the DHCP Interface Client table."
INDEX { ifIndex, dhcpIfClientIpAddress }
::= { dhcpIfClientTable 1 }
DhcpIfClientEntry ::=
SEQUENCE {
dhcpIfClientIpAddress
IpAddress,
dhcpIfClientRowStatus
RowStatus
}
dhcpIfClientIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DHCP Client IP Address."
::= { dhcpIfClientEntry 2 }
dhcpIfClientRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status used for creating, modifying, and deleting instances
of the columnar objects in the dhcpIfClientTable.
For Vmux Devices, it will be possible only to Delete instances.
The addition of Clients will be done automatically by the Server according
to Network messages that are sent by the Clients; not via SNMP.
In order to Delete a Client, this MIB object should be set to: destroy (6)."
::= { dhcpIfClientEntry 3 }
dhcpServerAction OBJECT-TYPE
SYNTAX INTEGER {
noOp(2),
deleteAllClients(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable enables the operator to perform one of the
specified actions on the Server.
deleteAllClients (3) is an option that is used for a device functioning as a server.
It will remove all the clients from all the interfaces of the device.
When the operation is complete, the agent will return a noOp (2) value."
::= { wrConfigIpDhcp 8 }
-- DHCP Client Table (New)
dhcpClientNTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpClientNEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DHCP Client table (New)."
::= { wrConfigIpDhcp 9 }
dhcpClientNEntry OBJECT-TYPE
SYNTAX DhcpClientNEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of this table."
INDEX { dhcpClientIndex }
::= { dhcpClientNTable 1 }
DhcpClientNEntry ::=
SEQUENCE {
dhcpClientIndex Unsigned32,
dhcpClientAdminStatus INTEGER,
dhcpClientOperStatus INTEGER,
dhcpClientAddressType InetAddressType,
dhcpClientAddress InetAddress,
dhcpClientAddressMask InetAddress,
dhcpClientNextHop InetAddress,
dhcpClientServerAddress InetAddress,
dhcpClientActualLeaseTime Unsigned32,
dhcpClientRemainLeaseTime Unsigned32,
dhcpClientCommand INTEGER,
dhcpClientOpAdminStatus BITS,
dhcpClientOpVendorClassId SnmpAdminString, -- option 60
dhcpClientOpIpAddrLeaseTime Unsigned32, -- option 51
dhcpClientOpServerId IpAddress, -- option 54
dhcpClientOpClientIdType Unsigned32, -- option 61
dhcpClientOpClientId SnmpAdminString, -- option 61
dhcpClientOpHostName SnmpAdminString, -- option 12
dhcpClientOpDns OCTET STRING, -- option 6
dhcpClientOpTftpServerName SnmpAdminString, -- option 66
dhcpClientOpBootFileName SnmpAdminString -- option 67
}
dhcpClientIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DHCP Client index.
Index can be ifIndex and/or index of a router interface or host."
::= { dhcpClientNEntry 1 }
dhcpClientAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
down (2),
up (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Administrative Status of DHCP client."
::= { dhcpClientNEntry 2 }
dhcpClientOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
notHoldingLease (2),
holdingLease (3),
locatingAvailableServer (4),
failedToGetLease (5),
initializing (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Operational Status of DHCP client."
::= { dhcpClientNEntry 3 }
dhcpClientAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Address Type of all InetAddress objects."
::= { dhcpClientNEntry 4 }
dhcpClientAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DHCP Client Address, which is assigned by the DHCP server."
::= { dhcpClientNEntry 5 }
dhcpClientAddressMask OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DHCP Client Address Mask, which is assigned by the DHCP server."
::= { dhcpClientNEntry 6 }
dhcpClientNextHop OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Next Hop (Default Gateway) of the DHCP client."
::= { dhcpClientNEntry 7 }
dhcpClientServerAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DHCP Server Address.
Although object is defined as read-write, current support is read-only."
::= { dhcpClientNEntry 8 }
dhcpClientActualLeaseTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Actual Lease Time (for Address received from the server),
measured in seconds.
Value=FFFFFFFF represents an infinite actual lease time."
::= { dhcpClientNEntry 9 }
dhcpClientRemainLeaseTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Remaining Lease Time (for Address received from the server),
measured in seconds.
Value=FFFFFFFF represents an infinite remaining lease time."
::= { dhcpClientNEntry 10 }
dhcpClientCommand OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
renew (3), -- renew current lease
release (4) -- release current lease
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The possible commands of DHCP client to DHCP server.
Upon performing a command, value should be automatically returned to off(2)."
::= { dhcpClientNEntry 11 }
dhcpClientOpAdminStatus OBJECT-TYPE
SYNTAX BITS
{
vendorClassId (0), -- Vendor Class Identifier (option 60)
ipAddrLeaseTime (1), -- IP Address Lease Time (option 51)
serverId (2), -- Server Identifier (option 54)
clientId (3), -- Client Identifier (option 61)
hostName (4), -- Host Name (option 12)
dns (5), -- Domain Name Server (DNS) (option 6)
tftpServerName (6), -- TFTP Server Name (option 66)
bootFileName (7) -- Boot File Name (option 67)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Administrative Status of the different options.
Bit=1 means that respective option is enabled/activated."
REFERENCE
"RFC-2132."
::= { dhcpClientNEntry 12 }
dhcpClientOpVendorClassId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Vendor Class Identifier.
Identifier should include at least 1 character."
REFERENCE
"RFC-2132, Option 60, Identifier."
::= { dhcpClientNEntry 13 }
dhcpClientOpIpAddrLeaseTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Address Lease Time, measured in seconds."
REFERENCE
"RFC-2132, Option 51, Time."
::= { dhcpClientNEntry 14 }
dhcpClientOpServerId OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Server Identifier (reported IP Address)."
REFERENCE
"RFC-2132, Option 54, IPv4 Address."
::= { dhcpClientNEntry 15 }
dhcpClientOpClientIdType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Client Identifier Type.
Type=0 indicates that Client Identifier is a string,
which is set by dhcpClientOpClientId.
Type=1 indicates that Client Identifier represents
the Ethernet Hardware Address (MAC)."
REFERENCE
"RFC-2132, Option 61, Type."
::= { dhcpClientNEntry 16 }
dhcpClientOpClientId OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Client Identifier.
Identifier should include at least 1 character.
When Type=1 (dhcpClientOpClientIdType),
it means that current object is read-only
as it represents the Ethernet Hardware Address (MAC)."
REFERENCE
"RFC-2132, Option 61, Identifier."
::= { dhcpClientNEntry 17 }
dhcpClientOpHostName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Host Name.
Name should include at least 1 character."
REFERENCE
"RFC-2132, Option 12, Host."
::= { dhcpClientNEntry 18 }
dhcpClientOpDns OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Domain Name Server (DNS),
which is a list of servers available to the client.
This object should include at least 4 octets
and must always be a multiple of 4 octets."
REFERENCE
"RFC-2132, Option 6, List of Addresses."
::= { dhcpClientNEntry 19 }
dhcpClientOpTftpServerName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The TFTP Server Name.
Name should include at least 1 character."
REFERENCE
"RFC-2132, Option 66, Server."
::= { dhcpClientNEntry 20 }
dhcpClientOpBootFileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Boot File Name.
Name should include at least 1 character."
REFERENCE
"RFC-2132, Option 67, Name."
::= { dhcpClientNEntry 21 }
wrDNSRelayAction OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Enabled, device will act as a DNS Relay:
whenever the device receives a DNS request from its host,
it will forward it to the DNS server
as if the request was initiated by the device itself.
The reply from the DNS server is forwarded by the
device to the host as if the device
was answering the request."
::= { wrConfigIpDNS 1 }
wrConfigIpxRouterInfo OBJECT IDENTIFIER ::= { webranger 3 }
wrAutoLearnLanIpxNets OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Activating (disable/enable) the auto-learn operation."
::= { wrConfigIpxRouterInfo 1 }
wrLanIpxNetTable OBJECT-TYPE
SYNTAX SEQUENCE OF WrLanIpxNetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Lan IPX nets Table."
::= { wrConfigIpxRouterInfo 2 }
wrLanIpxNetEntry OBJECT-TYPE
SYNTAX WrLanIpxNetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IPX Nets per frame type & LAN port. The table entries
will be created by the agent"
INDEX { wrLanifIndex, wrLanIpxFrameType }
::= { wrLanIpxNetTable 1 }
WrLanIpxNetEntry ::=
SEQUENCE {
wrLanifIndex
Integer32,
wrLanIpxFrameType
INTEGER,
wrIpxNetAddress
IpAddress
}
wrLanifIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LAN port ifIndex."
::= { wrLanIpxNetEntry 1 }
wrLanIpxFrameType OBJECT-TYPE
SYNTAX INTEGER{
t8023 (1),
ethernet (2),
t8022(3),
snap (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frame Type"
::= { wrLanIpxNetEntry 2 }
wrIpxNetAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Net address per Frame Type & LAN port."
::= { wrLanIpxNetEntry 3 }
wrDialInIpxNet OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Net address through a link."
::= { wrConfigIpxRouterInfo 3 }
-- The RIP/SAP Interface Configuration Table.
ripSapIfConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RipSapIfConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Interfaces which require separate
configuration in RIP/SAP."
::= { wrConfigIpxRouterInfo 4 }
ripSapIfConfEntry OBJECT-TYPE
SYNTAX RipSapIfConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A Single Routing Domain in a single Subnet."
INDEX { ripSapIfConfIfIndex }
::= { ripSapIfConfTable 1 }
RipSapIfConfEntry ::=
SEQUENCE {
ripSapIfConfIfIndex
Integer32,
ripSapIfConfMode
INTEGER,
ripSapIfConfStatus
RowStatus
}
ripSapIfConfIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface ifIndex."
::= { ripSapIfConfEntry 1 }
ripSapIfConfMode OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ifIndex RIP/SAP mode."
::= { ripSapIfConfEntry 2 }
ripSapIfConfStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute allows to create/delete a row in this table.
For creating a row, the NMS should set
ripSapIfConfStatus.id1 = active(1).
For destroying a row, the NMS should set:
ripSapIfConfStatus.id1 = destroy(6).
Only rows with status active(1) are relevant.
The only possible supported RowStatus vaules are
active (1) and destroy (6)."
::= { ripSapIfConfEntry 3 }
wrInterface OBJECT IDENTIFIER ::= { webranger 4 }
wrIpAddressTable OBJECT-TYPE
SYNTAX SEQUENCE OF WrIpAddressEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link IP addresses Table."
::= { wrInterface 1 }
wrIpAddressEntry OBJECT-TYPE
SYNTAX WrIpAddressEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ip Address per Link"
INDEX { wrIpIfIndex }
::= { wrIpAddressTable 1 }
WrIpAddressEntry ::=
SEQUENCE {
wrIpIfIndex
Integer32,
wrIpAddress
IpAddress,
wrIpMask
IpAddress,
wrIpRowStatus
RowStatus
}
wrIpIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port interface index."
::= { wrIpAddressEntry 1 }
wrIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Link IP Address."
::= { wrIpAddressEntry 2 }
wrIpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Link IP mask Address."
::= { wrIpAddressEntry 3 }
wrIpRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute allows to create/delete a row in this table.
For creating a row, the NMS should set
wrIpRowStatus.id1 = active(1).
For destroying a row, the NMS should set:
wrIpRowStatus.id1 = destroy(6).
Only rows with status active(1) are relevant.
The only possible supported RowStatus vaules are
active (1) and destroy (6)."
::= { wrIpAddressEntry 4 }
wrSpoofingTable OBJECT-TYPE
SYNTAX SEQUENCE OF WrSpoofingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Spoofing Table."
::= { wrInterface 2 }
wrSpoofingEntry OBJECT-TYPE
SYNTAX WrSpoofingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Spoofing per Link"
INDEX { wrSpoofingIfIndex }
::= { wrSpoofingTable 1 }
WrSpoofingEntry ::=
SEQUENCE {
wrSpoofingIfIndex
Integer32,
wrSpoofingAction
Integer32,
wrSpoofingAgingStation
Integer32,
wrSpoofingRowStatus
RowStatus
}
wrSpoofingIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port interface index."
::= { wrSpoofingEntry 1 }
wrSpoofingAction OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Spoofing action is applied by bit code:
enable : bit 0 set (disable: bit 0 is 0)
keepAlive : bit 1
... : bit 2
and so on.
For the above example, to set spoofing to keepAlive action,
the object's value will be 3 = [ 2**0 + 2**1 ]
Only the Remote WEBRANger will accept this object !
------- "
::= { wrSpoofingEntry 2 }
wrSpoofingAgingStation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" Aging time of stations list, in min. The agent 'translates'
the time entered in minutes, to 10 min. resolution, as
follows:
1..10 min - 10 min
11..20 min - 20 min
and so on...
0 is not a valid value.
Only the Remote WEBRANger will accept this object !
---------------- "
::= { wrSpoofingEntry 3 }
wrSpoofingRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute allows to create/delete a row in this table.
For creating a row, the NMS should set
wrSpoofingRowStatus.id1 = active(1).
For destroying a row, the NMS should set:
wrSpoofingRowStatus.id1 = destroy(6).
Only rows with status active(1) are relevant.
The only possible supported RowStatus vaules are
active (1) and destroy (6)."
::= { wrSpoofingEntry 4 }
wrLanIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF WrLanIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link IP addresses Table."
::= { wrInterface 3 }
wrLanIfEntry OBJECT-TYPE
SYNTAX WrLanIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ip Address per Link"
INDEX { wrLanIfIndex }
::= { wrLanIfTable 1 }
WrLanIfEntry ::=
SEQUENCE {
wrLanIfIndex
Integer32,
wrLanBridgeRouterMode
INTEGER,
wrLanIfState
INTEGER,
wrLanIfRdnTimeout
Integer32
}
wrLanIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port interface index."
::= { wrLanIfEntry 1 }
wrLanBridgeRouterMode OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
bridge (2),
ipRouter (3),
ipxRouter (4),
ipAndIpxRouter (5),
bRouter (6),
ipBrouter (7),
ipxBrouter (8),
ipAndIpxBrouter (9),
bridgeAndStp (10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates whether the link is Bridge
or Router and specifies the Router's type."
::= { wrLanIfEntry 2 }
wrLanIfState OBJECT-TYPE
SYNTAX INTEGER {
disable(2),
enable (3),
redundancy(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The LAN is disabled or enabled.
For LAN 2 it can be also 'redundancy'."
::= { wrLanIfEntry 3 }
wrLanIfRdnTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"LAN Redundancy Timeout in seconds.
Applicable when wrLanIfState=redundancy."
::= { wrLanIfEntry 4 }
wrSyncCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF WrSyncCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration table for Async interface."
::= { wrInterface 4 }
wrSyncCnfgEntry OBJECT-TYPE
SYNTAX WrSyncCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration table"
INDEX { wrSyncIfIndex }
::= { wrSyncCnfgTable 1 }
WrSyncCnfgEntry ::=
SEQUENCE {
wrSyncIfIndex
Integer32,
wrSyncClkMode
INTEGER,
wrSyncClkRate
INTEGER
}
wrSyncIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sync interface index."
::= { wrSyncCnfgEntry 1 }
wrSyncClkMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
manual (2),
program (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock Mode."
::= { wrSyncCnfgEntry 2 }
wrSyncClkRate OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
r16 (2),
r32 (3),
r48 (4),
r64 (5),
r96 (6),
r128 (7),
r256 (8),
r768 (9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock Rate in. Rate can be changed if Clock Mode is Program only."
::= { wrSyncCnfgEntry 3 }
wrFrCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF WrFrCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration table for Fr parameters that do not exist in RFC2115."
::= { wrInterface 5 }
wrFrCnfgEntry OBJECT-TYPE
SYNTAX WrFrCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration entry for Fr parameters that do not exist in RFC2115."
INDEX { ifIndex }
::= { wrFrCnfgTable 1 }
WrFrCnfgEntry ::=
SEQUENCE {
wrFrDlciLearningMode
INTEGER,
wrFrCllmMessages
INTEGER
}
wrFrDlciLearningMode OBJECT-TYPE
SYNTAX INTEGER {
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter enables the webranger to learn the DLCi's
configuration and maintanance protocol for the current interface.
off - the WR will read the user's configuration for this interface.
on - the WR will begin self learning of the current interface's maintanance
protocol and DLCIs."
::= { wrFrCnfgEntry 1 }
wrFrCllmMessages OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter enables/disables the Webranger to Tx/Rx CLLM
(Consolidated Link Layer Management) messages via DLCI 1023.
The CLLM messages are link layer control messages. They can be used for example
in cases of congestion. The CLLM message contains a code for cause of congestion
and list of all DLCIs that should act to reduce data transmission."
::= { wrFrCnfgEntry 2 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\iprouter.txt
--
--Version: 1.0
--Date: 31.01.99
--By: Ilana Schvetz
--File: ipRouter.txt
--
--Last update: 21-Sep-2006 by Ilana Schvetz
--radRouter OBJECT IDENTIFIER ::= { rad 11 }
--rtrBridge OBJECT IDENTIFIER ::= { radRouter 7 }
ipRouter OBJECT IDENTIFIER ::= { rtrBridge 3 }
rtrIfIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrIfIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Router interfaces table."
::= { ipRouter 1 }
rtrIfIpEntry OBJECT-TYPE
SYNTAX RtrIfIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table rtrIfIpTable."
INDEX { rtrIfIp }
::= { rtrIfIpTable 1 }
RtrIfIpEntry ::=
SEQUENCE {
rtrIfIp IpAddress,
rtrIfRowStatus RowStatus,
rtrIfIpMask IpAddress,
rtrIfIndex Integer32,
rtrIfMng INTEGER,
rtrIfVlanId VlanIndex
}
rtrIfIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP Address."
::= { rtrIfIpEntry 1 }
rtrIfRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"."
::= { rtrIfIpEntry 2 }
rtrIfIpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"IP mask Address."
::= { rtrIfIpEntry 3 }
rtrIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ifIndex connection, on which the IP is determined."
::= { rtrIfIpEntry 4 }
rtrIfMng OBJECT-TYPE
SYNTAX INTEGER {
no (1),
yes (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An IP interface might be determined as a management
connection (under the product limitations)."
::= { rtrIfIpEntry 5 }
rtrIfVlanId OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The VLAN ID assigned to Tagged frames transmitted
from this port.
The value inserted should be a defined VLAN."
::= { rtrIfIpEntry 6 }
-- Brouter Table
brtrIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF BrtrIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"LAN interface table."
::= { ipRouter 2 }
brtrIfEntry OBJECT-TYPE
SYNTAX BrtrIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entries of this table will be created by agent."
INDEX { brtrIfIndex }
::= { brtrIfTable 1 }
BrtrIfEntry ::=
SEQUENCE {
brtrIfIndex Integer32,
brtrIfMode INTEGER,
brtrIfMaxFrameSize Integer32
}
brtrIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the interface (LAN or ATM)."
::= { brtrIfEntry 1 }
brtrIfMode OBJECT-TYPE
SYNTAX INTEGER {
bridge (1),
router (2),
brouter (3),
off (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Connection Mode."
::= { brtrIfEntry 2 }
brtrIfMaxFrameSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frame Max Size."
::= { brtrIfEntry 3 }
rtrArpAgingTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ARP Aging Time. Applicable for a Router Mode
and for a Brouter Mode."
::= { ipRouter 3 }
-- Brouter LAN If table
brtrLanIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF BrtrLanIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"LAN interface table."
::= { ipRouter 4 }
brtrLanIfEntry OBJECT-TYPE
SYNTAX BrtrLanIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entries of this table will be created by agent ."
INDEX { brtrLanIfIndex }
::= { brtrLanIfTable 1 }
BrtrLanIfEntry ::=
SEQUENCE {
brtrLanIfIndex Integer32,
brtrLanIpAddress IpAddress,
brtrLanIpMask IpAddress,
brtrLanMaxRateEnable INTEGER,
brtrLanMaxRate Integer32,
brtrLanMng INTEGER,
brtrLanDefaultRouter IpAddress
}
brtrLanIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the LAN entity (physical interface)."
::= { brtrLanIfEntry 1 }
brtrLanIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Host IP address. Applicable for bridge mode connection only."
::= { brtrLanIfEntry 2 }
brtrLanIpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Host IP Mask. Applicable for bridge mode connection only."
::= { brtrLanIfEntry 3 }
brtrLanMaxRateEnable OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter determines the HW ability of the LAN
card according to HW."
::= { brtrLanIfEntry 4 }
brtrLanMaxRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Max Rate."
::= { brtrLanIfEntry 5 }
brtrLanMng OBJECT-TYPE
SYNTAX INTEGER {
no (1),
yes (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An IP interface might be determined as a management
connection (under the product limitations)."
::= { brtrLanIfEntry 6 }
brtrLanDefaultRouter OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default Router's (Gateway's) IP Address.
For each LAN interface there may be a different Default Router."
::= { brtrLanIfEntry 7 }
rtrIsdnIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrIsdnIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains ISDN parameters that do not appear in the standard MIBs."
::= { ipRouter 5 }
rtrIsdnIfEntry OBJECT-TYPE
SYNTAX RtrIsdnIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries for ISDN parameters that do not appear in the standard MIBs."
AUGMENTS { isdnSignalingEntry }
-- INDEX { isdnSignalingIndex }
::= { rtrIsdnIfTable 1 }
RtrIsdnIfEntry ::=
SEQUENCE {
rtrIsdnIfMinNumBchans Integer32,
rtrIsdnIfMaxNumBchans Integer32
}
rtrIsdnIfMinNumBchans OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Minimum number of B channels that the ISDN Dialer of the router will use
for Dialing out.
This parameter will be used for the BOD (Bandwidth On Demand) feature.
Dial up on B channels is according to the need of bandwidth for router
data transfer. Voice calls have a higher priority than router data.
In case of few time slots the voice calls will cause disconnection of
data channels up to the limit of minimum number of B channels."
::= { rtrIsdnIfEntry 1 }
rtrIsdnIfMaxNumBchans OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Maximum number of B channels that the ISDN Dialer of the router will use
for Dialing out.
This parameter will be used for the BOD (Bandwidth On Demand) feature.
Dial up on B channels is according to the need of bandwidth for router
data transfer. Voice calls have a higher priority than router data.
No more than MAX B channels will be used by the ISDN dialer."
::= {rtrIsdnIfEntry 2 }
rtrLcrTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrLcrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Least Cost Routing Table.
The user will be able to set a prefix for an outgoing number
that arrives with a predefined prefix in order to redirect
the number for the LCR process to be achieved."
::= { ipRouter 6 }
rtrLcrEntry OBJECT-TYPE
SYNTAX RtrLcrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Least Cost Routing Entry."
INDEX { ifIndex, rtrLcrOutIfIndex }
::= { rtrLcrTable 1 }
RtrLcrEntry ::=
SEQUENCE {
rtrLcrOutIfIndex InterfaceIndex,
rtrLcrRowStatus RowStatus,
rtrLcrInPrefix DisplayString,
rtrLcrOutPrefix DisplayString
}
rtrLcrOutIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The outgoing interface Number of the current route.
The incoming interface number is the value of ifIndex."
::= { rtrLcrEntry 1 }
rtrLcrRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row Status for adding/destroying rows."
::= { rtrLcrEntry 2 }
rtrLcrInPrefix OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This prefix is part of the called number existing in the incoming packet."
::= {rtrLcrEntry 3 }
rtrLcrOutPrefix OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This prefix will be inserted into the outgoing packet."
::= {rtrLcrEntry 4 }
--radRouter OBJECT IDENTIFIER ::= { rad 11 }
multicastGen OBJECT IDENTIFIER ::= { radRouter 8 } -- General Multicast Parameters
multicastMode OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
wanToLan (3),
wanToLanIgmp (4),
lanToWan (5),
bidirectional(6),
transparent(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"According to this mode the packets will be forwarded.
If disable (2) is selected, there will be no multicast."
::= { multicastGen 1 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\v5.txt
--
--Title: RAD's WAN V5.1 Interface MIB
--By: Smadar Tauber
--Date : 03.11.1998
--Last Update: 27-June-05
--By: Smadar Tauber
--File: v:\doc\rdv\mib\ver520\v5.txt
--IMPORTS
-- enterprises FROM RFC1155-SMI
-- DisplayString FROM RFC1213-MIB
-- IpAddress FROM RFC1155-SMI
-- OCTET STRING FROM RFC1213-MIB
-- OBJECT-TYPE FROM RFC1212;
--wanGen OBJECT IDENTIFIER ::= {radWan 1}
--diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6} (see mpmx.txt)
v51If OBJECT IDENTIFIER ::= {diverseIfWanGen 6}
v51General OBJECT IDENTIFIER ::= {v51If 1}
v51Variant OBJECT IDENTIFIER ::= {v51If 2}
v51Ml OBJECT IDENTIFIER ::= {v51If 3}
v51AccessPort OBJECT IDENTIFIER ::= {v51If 4}
--NPL parameters (for most of the manual parameters see TDSoft MIB)
npl OBJECT IDENTIFIER ::= {v51General 1}
nplMode OBJECT-TYPE
SYNTAX INTEGER
{
auto (2),
manual(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"NPL Mode."
::= { npl 1 }
nplCountry OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
france (2),
germany (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"National Protocol Country."
::= { npl 2 }
nplVoicePathDuration OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum time of a voice path, in msec."
::= { npl 3 }
--NPL Pulse table
nplPulseTable OBJECT-TYPE
SYNTAX SEQUENCE OF NplPulseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"NPL Pulse table. This table is written directly to the agent."
::= { npl 4 }
nplPulseEntry OBJECT-TYPE
SYNTAX NplPulseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table nplPulseTable."
INDEX {nplPulseType}
::= { nplPulseTable 1}
NplPulseEntry ::=
SEQUENCE {
nplPulseType INTEGER,
nplPulseValid INTEGER,
nplPulseDurationType Integer32,
nplPulseOnTime Integer32,
nplPulseOffTime Integer32
}
nplPulseType OBJECT-TYPE
SYNTAX INTEGER
{
meteringPulse1 (1),
meteringPulse2 (2),
initRinging1 (3),
initRinging2 (4),
normalBattery (237),
noBattery (250),
reducedBattery (251),
reversePolarity(254),
normalPolarity (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pulse Type"
::= {nplPulseEntry 1}
nplPulseValid OBJECT-TYPE
SYNTAX INTEGER
{
notValid (2),
valid (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Validity of the Pulse Type."
::= {nplPulseEntry 2}
nplPulseDurationType OBJECT-TYPE
SYNTAX Integer32 (0..31)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Pulse Duration Type.
- If meteringPulse1 and meteringPulse2 are both 'valid', the value of this
object must be different for them.
- If initRinging1 and initRinging2 are both 'valid', the value of this
object must be different for them."
::= {nplPulseEntry 3}
nplPulseOnTime OBJECT-TYPE
SYNTAX Integer32 (0..990)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"How much time the pulse is ON, in msec.
0 is a valid value only when nplPulseValid=notValid."
::= {nplPulseEntry 4}
nplPulseOffTime OBJECT-TYPE
SYNTAX Integer32 (0..990)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"How much time the pulse is OFF, in msec."
::= {nplPulseEntry 5}
--Variant tables
--
--Variant table - Configuration and Status at Variant Level
--
--Only ONE variant exists per link in the Temporary Configuration
v51VarTable OBJECT-TYPE
SYNTAX SEQUENCE OF V51VarEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { v51Variant 1}
v51VarEntry OBJECT-TYPE
SYNTAX V51VarEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table v51VarTable."
INDEX {v51VarCnfgIdx, v51VarSltIdx, v51VarPrtIdx, v51VarIdx }
::= { v51VarTable 1}
V51VarEntry ::=
SEQUENCE {
v51VarCnfgIdx Integer32,
v51VarSltIdx INTEGER,
v51VarPrtIdx Integer32,
v51VarIdx Integer32,
v51VarPstnCch INTEGER,
v51VarIsdnSTypeCch INTEGER,
v51VarDescription DisplayString,
v51VarStatus INTEGER,
v51VarRowStatus INTEGER
}
v51VarCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg being accessed.
255 = TmpCnfg.
1 = Current Cnfg.
Write is allowed only to TmpCnfg."
::= {v51VarEntry 1}
v51VarSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot Index.
For V5.2, this index will be the Slot of the V5.2 Master ML."
::= {v51VarEntry 2}
v51VarPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number of the ML having
V5 interface.
Valid values: exPrt1 (1)..exPrt4 (4), inPrt1(101)..inPrt4(104),
notApplicable(255) - for V5.2 only."
::= {v51VarEntry 3}
v51VarIdx OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Variant Id.
Valid values:
- for Current Cnfg: 0..127
- for Tmp Cnfg: until MP R9 : 255 only.
from MP R10: 0..127."
::= {v51VarEntry 4}
v51VarPstnCch OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
ts15 (2),
ts16 (3),
ts31 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates which TS will be used for PSTN C channel.
For V5.2 - notApplicable."
::= {v51VarEntry 5}
v51VarIsdnSTypeCch OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
ts15 (2),
ts16 (3),
ts31 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates which TS will be used for S-Type C channel.
For V5.2 - notApplicable."
::= {v51VarEntry 6}
v51VarDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object describes the Variant."
::= {v51VarEntry 7}
v51VarStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
notActive (2),
active (3),
activeReq (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reports the status of an existing Variant of a link.
notActive - the variant exists on this link but is not active
active - the variant exists on this link AND is active
activeReq - the variant exists on this link and it was requested to
be active, but the request is still in negotiation
(it can be either accepted as active, or not).
This object is not applicable for v51VarCnfgIdx=255=TmpCnfg."
::= {v51VarEntry 8}
v51VarRowStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
notValid (2),
valid (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables to create new entries and delete existing entries
from the table. It is applicable only from MP R10."
::= {v51VarEntry 9}
--Variant Configuration and Status table - TS/Address Level
v51VarCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF V51VarCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { v51Variant 2}
v51VarCfgEntry OBJECT-TYPE
SYNTAX V51VarCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table v51VarCfgTable."
INDEX {v51VarCfgIndex, v51VarCfgSltIdx, v51VarCfgPrtIdx, v51VarCfgIdx,
v51VarCfgTsIdx}
::= { v51VarCfgTable 1}
V51VarCfgEntry ::=
SEQUENCE {
v51VarCfgIndex Integer32,
v51VarCfgSltIdx INTEGER,
v51VarCfgPrtIdx Integer32,
v51VarCfgIdx Integer32,
v51VarCfgTsIdx Integer32,
v51VarCfgTsType INTEGER,
v51VarCfgPrtId Integer32,
v51VarCfgEfL3Addr Integer32,
v51VarCfgFTypeCch Integer32,
v51VarCfgPTypeCch Integer32,
v51VarCfgConSlt INTEGER,
v51VarCfgConPrt Integer32,
v51VarCfgIoState INTEGER,
v51VarCfgBlock INTEGER,
v51VarCfgExtDch INTEGER,
v51VarCfgExtDchSlot INTEGER,
v51VarCfgExtDchPort Integer32,
v51VarCfgExtDchTs Integer32,
v51VarCfgExtDchCmpr INTEGER,
v51VarCfgExtDchRate INTEGER,
v51VarCfgExtDchStartBit Integer32,
v51VarCfgSTypeCch Integer32,
v51VarCfgStatus INTEGER,
v51VarCfgV52MasterTsa Integer32
}
v51VarCfgIndex OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg being accessed.
255 = TmpCnfg.
1 = Current Cnfg. "
::= {v51VarCfgEntry 1}
v51VarCfgSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot Index.
For V5.2, this index will be the Slot of the V5.2 Master ML."
::= {v51VarCfgEntry 2}
v51VarCfgPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number of the ML having
V5 interface.
Valid values: exPrt1 (1)..exPrt4 (4), inPrt1(101)..inPrt4(104)
notApplicable(255) - for V5.2 only."
::= {v51VarCfgEntry 3}
v51VarCfgIdx OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Variant Id.
Valid values:
- for Current Cnfg: 0..127
- for Tmp Cnfg: until MP R9 : 255 only.
from MP R10: 0..127."
::= {v51VarCfgEntry 4}
v51VarCfgTsIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For V5.1: Time Slot index (1..31).
For V5.2: Running Index (1..1320) for Address Table."
::= {v51VarCfgEntry 5}
v51VarCfgTsType OBJECT-TYPE
SYNTAX INTEGER
{
nc (1),
pstn (2),
isdnB1 (3),
isdnB2 (4),
cChannel (5),
permanentB1 (6),
permanentB2 (7),
semiPermanentB1 (8),
semiPermanentB2 (9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time Slot Type."
::= {v51VarCfgEntry 6}
v51VarCfgPrtId OBJECT-TYPE
SYNTAX Integer32 (0..16777215)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the IO Port Id this TS is connected to.
For V5.2, the Port Id is a concatenation of SS:PP:TS of the port
connected to V5.2 Master.
SS=IO Slot (1..12)
PP=Port (01..16)
TS = TS (00 for ports that don't have TSs, 1 ..31).
Example: 50327 means IO-5, port-3, TS27.
222222 value is used for a special PSTN case."
::= {v51VarCfgEntry 7}
v51VarCfgEfL3Addr OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Address of the IO port this TS is connected to.
The IO port is identified according to its Address:
- for ISDN ports: EF Address. Valid values: 0..8175
- for PSTN ports: L3 Address. Valid values: 0..32767
65535=notApplicable (FFFF)."
::= {v51VarCfgEntry 8}
v51VarCfgFTypeCch OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For V5.1 - this object indicates which TS will be used for F-Type C channel.
notApplicable (1),
ts15 (2),
ts16 (3),
ts31 (4)
For V5.2 - this object indicates the Logical C Channel F Type (0..65535).
65536=not applicable in this case."
::= {v51VarCfgEntry 9}
v51VarCfgPTypeCch OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For V5.1 - This object indicates which TS will be used for P-Type C channel.
notApplicable (1),
ts15 (2),
ts16 (3),
ts31 (4)
For V5.2 - this object indicates the Logical C Channel P Type (0..65535).
65536=not applicable in this case."
::= {v51VarCfgEntry 10}
v51VarCfgConSlt OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Slot containing the IO port this TS is connected to.
For V5.2 this object is notApplicable."
::= {v51VarCfgEntry 11}
v51VarCfgConPrt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IO Port this TS is connected to.
Valid values: exPrt1 (1)..exPrt12 (12), inPrt1(101)..inPrt4(104).
100=noConnect
For V5.2 this object is notApplicable=255."
::= {v51VarCfgEntry 12}
v51VarCfgIoState OBJECT-TYPE
SYNTAX INTEGER
{
notUsed (1),
normal (2),
blockReqDenied (3),
remoteBlocked (4),
localBlocked (5),
unblockReqDenied(6),
duringBlock (7),
duringUnblock (8),
localLoop (9),
remoteLoop (10),
localUnblock (11),
remoteUnblock (12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The State of the IO port this TS is connected to.
This object is not applicable for v51VarCfgIndex=255=TmpCnfg.
normal(2) - will be used for operating normally (operate)
localBlocked(5) - will be used for general Block state"
::= {v51VarCfgEntry 13}
v51VarCfgBlock OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
unBlock (2),
block (3),
blockRequest (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if this TS will be Blocked or not and how:
block - done locally
blockRequest - according to external request of the telephone exchange."
::= {v51VarCfgEntry 14}
v51VarCfgExtDch OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For V5.1: This object indicates if this TS is an ISDN D channel that
comes via Bypass from a non-V5.1 ML.
For V5.2: this object will be notApplicable (not supported)."
::= {v51VarCfgEntry 15}
v51VarCfgExtDchSlot OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only if v51VarCfgExtDch=yes(3).
It indicates the Slot of the non-V5.1 ML on which the External D channel
TS is defined (and is transferred via Bypass between the V5.1 ML and
the non-V5.1 ML.)
Not Applicable for V5.2 (it is part of Port Id)."
::= {v51VarCfgEntry 16}
v51VarCfgExtDchPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only if v51VarCfgExtDch=yes(3).
It indicates the Port on the Slot of 'v51VarCfgExtDchSlot' of the
non-V5.1 ML on which the External D channel TS is defined (and is
transferred via Bypass between the V5.1 ML and the non-V5.1 ML.)
Valid values: exPrt1 (1)..exPrt4 (4), inPrt1(101)..inPrt4(104).
100=noConnect.
Not Applicable for V5.2 (255; it is part of Port Id)."
::= {v51VarCfgEntry 17}
v51VarCfgExtDchTs OBJECT-TYPE
SYNTAX Integer32 (0..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only if v51VarCfgExtDch=yes(3).
It indicates the TS on the non-V5 ML on which the External
D channel TS is defined (and is transferred via Bypass between
the V5 ML and the non-V5 ML.)
For V5.1: 0=notApplicable
For V5.2: 0=None, 32=notApplicable."
::= {v51VarCfgEntry 18}
v51VarCfgExtDchCmpr OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For V5.1 - this object is applicable only if v51VarCfgExtDch=yes(3).
It indicates if this ISDN D channel TS is Compressed or not."
::= {v51VarCfgEntry 19}
v51VarCfgExtDchRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
twoBits (2),
fourBits (3),
eightBits (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For V5.1 - this object is applicable only if v51VarCfgExtDch=yes(3).
It indicates the Rate of the ISDN D channel."
::= {v51VarCfgEntry 20}
v51VarCfgExtDchStartBit OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For V5.1 - this object is applicable only if v51VarCfgExtDch=yes(3).
It indicates the Start Bit of the ISDN D channel on the TS of
the non-V5.1 ML on which it is defined.
Valid values:
- for v51VarCfgExtDchRate=twoBits(2): 1, 3, 5, 7
- for v51VarCfgExtDchRate=fourBits(3): 1, 5
- for v51VarCfgExtDchRate=eightBits(4): 1
- 0=notApplicable "
::= {v51VarCfgEntry 21}
v51VarCfgSTypeCch OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is supported only by V5.2. It indicates the Logical
C Channel S Type (0..65535).
65536=not applicable."
::= {v51VarCfgEntry 22}
v51VarCfgStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
notValid (2),
valid (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is supported only by V5.2.
It enables to create new entries and delete existing entries
from the table."
::= {v51VarCfgEntry 23}
v51VarCfgV52MasterTsa OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is supported only by V5.2.
This will be the V5.2 Master, Switch Allocated Location. It is
a concatenation of SS:PP:TS of the V5.2 Master.
It indicates which is the exact port and TS allocated by the Local
Exchange on the V5.2 Link.
SS=IO Slot (1..12)
PP=Port (01..04)
TS = TS (1..31).
Example: 50323 means IO-5, port-3, TS23."
::= {v51VarCfgEntry 24}
--Variant Configuration and Status table - C CH Level (V5.2 only)
v5VarCchTable OBJECT-TYPE
SYNTAX SEQUENCE OF V5VarCchEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { v51Variant 3}
v5VarCchEntry OBJECT-TYPE
SYNTAX V5VarCchEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table v5VarCchTable."
INDEX {v5VarCchCfgIndex, v5VarCchVarIdx, v5VarCchIdx}
::= { v5VarCchTable 1}
V5VarCchEntry ::=
SEQUENCE {
v5VarCchCfgIndex Integer32,
v5VarCchVarIdx Integer32,
v5VarCchIdx Integer32,
v5VarCchType INTEGER,
v5VarCchPhyLinkNo Integer32,
v5VarCchLogicalId Integer32,
v5VarCchTs Integer32,
v5VarCchPstn INTEGER,
v5VarCchIsdnTypes Integer32
}
v5VarCchCfgIndex OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg being accessed.
255 = TmpCnfg.
1 = Current Cnfg. "
::= {v5VarCchEntry 1}
v5VarCchVarIdx OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Variant Id.
Valid values: 0..127."
::= {v5VarCchEntry 2}
v5VarCchIdx OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"C-CH Id.
There are only 8 possible C-CHs per Variant."
::= {v5VarCchEntry 3}
v5VarCchType OBJECT-TYPE
SYNTAX INTEGER
{
none (2),
primary (3),
secondary (4),
regular (5),
standby (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"C-CH Type."
::= {v5VarCchEntry 4}
v5VarCchPhyLinkNo OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Physical Link Number of the card (1..4).
This object is applicable only if v51VarCchType is not 'none'.
notApplicable=255."
::= {v5VarCchEntry 5}
v5VarCchLogicalId OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Logical C-CH Id. (0..65535)
When v51VarCchType is 'none', this object is irrelevant."
::= {v5VarCchEntry 6}
v5VarCchTs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The C-CH TS. Valid values: 16, 15, 31.
If v51VarCchType=primary or secondary, the value must be 16 (RO).
This object is applicable only if v51VarCchType is not 'none'.
notApplicable=0."
::= {v5VarCchEntry 7}
v5VarCchPstn OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"PSTN C-CH.
Only one entry can have the value 'yes'.
notApplicable - when v51VarCchType is none, secondary or standby."
::= {v5VarCchEntry 8}
v5VarCchIsdnTypes OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ISDN Types of C-CH.
This object is a sum of 2**n, where n=Bit No. and Bit is '1':
Bit No. ISDN Type
0 P
1 F
2 S
Bit value '1'= Yes
Bit value '0'= No
Example: P=No, F=Yes, S=Yes (110H) will have the value 6.
Each Type is NA (notApplicable) when v51VarCchType is none, secondary
or standby. There is no special value for it, since each type can have
only 2 values (1 or 0). When this object is NA, Agent will not refer its value
(don't care)."
::= {v5VarCchEntry 9}
--Active Variant - Active Addresses Status table (V5.2 only)
v5VarStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF V5VarStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a RO table. It includes only the Active Addresses of
the Active Variant, their minimal Config data and Status."
::= { v51Variant 4}
v5VarStatEntry OBJECT-TYPE
SYNTAX V5VarStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table v5VarStatTable."
INDEX {v5VarStatIdx}
::= { v5VarStatTable 1}
V5VarStatEntry ::=
SEQUENCE {
v5VarStatIdx Integer32,
v5VarStatPrtId Integer32,
v5VarStatPortType INTEGER,
v5VarStatEfL3Addr Integer32,
v5VarStatPortState INTEGER,
v5VarStatMasterTsa Integer32,
v5VarStatCallState INTEGER
}
v5VarStatIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Running Index (1..120). Up to 120 calls can be active at the same time
on the Active Variant."
::= {v5VarStatEntry 1}
v5VarStatPrtId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the IO Port Id, the Address is connected to.
The Port Id is a concatenation of SS:PP:TS of the port connected
to an Address of the Active Variant running on the V5.2 Master card.
SS=IO Slot (1..12)
PP=Port (01..04)
TS = TS (00 for ports that don't have TSs ..31).
Example: 50327 means IO-5, port-3, TS27."
::= {v5VarStatEntry 2}
v5VarStatPortType OBJECT-TYPE
SYNTAX INTEGER
{
nc (1),
pstn (2),
isdnB1 (3),
isdnB2 (4),
cChannel (5),
permanentB1 (6),
permanentB2 (7),
semiPermanentB1 (8),
semiPermanentB2 (9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Address Port Type."
::= {v5VarStatEntry 3}
v5VarStatEfL3Addr OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the EF/L3 Address of the IO port this entry
is connected to.
The IO port is identified according to its EF/L3 Address:
- for ISDN ports: EF Address. Valid values: 0..8175
- for PSTN ports: L3 Address. Valid values: 0..32767
65535=notApplicable (FFFF)."
::= {v5VarStatEntry 4}
v5VarStatPortState OBJECT-TYPE
SYNTAX INTEGER
{
notUsed (1),
normalOperation (2),
block (5),
localUnblock (11),
remoteUnblock (12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The State of the IO port this Address entry is connected to.
The values were designed to match the relevant values of v51VarCfgIoState."
::= {v5VarStatEntry 5}
v5VarStatMasterTsa OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This will be the V5.2 Master Switch Allocated TSA Location. It is
a concatenation of SS:PP:TS of the V5.2 Master card.
It indicates which is the exact port and TS allocated by the Local
Exchange on the V5.2 Link.
SS=IO Slot (1..12)
PP=Port (01..04)
TS = TS (1..31).
Example: 50323 means IO-5, port-3, TS23."
::= {v5VarStatEntry 6}
v5VarStatCallState OBJECT-TYPE
SYNTAX INTEGER
{
empty (1),
outOfService (2),
deactive (3),
actInit (4),
accessAct (5),
plActInit (6),
plAct (7),
loopback2 (8),
loopback1 (9),
loopback1A (10),
null (11),
pathInit (12),
pathAbortReq (13),
lineInfo (14),
pathActive (15),
blocked (16),
disconnectReq (17)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Call State of the Address."
::= {v5VarStatEntry 7}
--V5 ML tables
v51MlCmdAndStatus OBJECT IDENTIFIER ::= {v51Ml 1}
v51MlCnfg OBJECT IDENTIFIER ::= {v51Ml 2}
--ML command/status table
v51MlTable OBJECT-TYPE
SYNTAX SEQUENCE OF V51MlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Variant Command and Status table."
::= { v51MlCmdAndStatus 1}
v51MlEntry OBJECT-TYPE
SYNTAX V51MlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table v51MlTable."
INDEX {v51MlSltIdx, v51MlPrtIdx}
::= { v51MlTable 1}
V51MlEntry ::=
SEQUENCE {
v51MlSltIdx INTEGER,
v51MlPrtIdx Integer32,
v51MlCurrActiveVar Integer32,
v51MlLeActiveReqVar Integer32,
v51MlProtocolState INTEGER,
v51MlUserActiveVarReq Integer32,
v51MlDeleteVarReq Integer32,
v51MlSaveVariant Integer32,
v51MlReadVariant Integer32,
v51MlDeactivateVar Integer32
}
v51MlSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot Index.
For V5.2 this index is notApplicable."
::= {v51MlEntry 1}
v51MlPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number of the ML having
V5 interface.
Valid values: exPrt1 (1)..exPrt4 (4), inPrt1(101)..inPrt4(104),
notApplicable(255) - for V5.2 only."
::= {v51MlEntry 2}
v51MlCurrActiveVar OBJECT-TYPE
SYNTAX Integer32 (0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For V5.1: the currently Active Variant Id. on this ML.
For V5.2: the currently Active Variant Id.
128=none."
::= {v51MlEntry 3}
v51MlLeActiveReqVar OBJECT-TYPE
SYNTAX Integer32 (0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For V5.1: the Variant Id. that the Local Exchange (LE)
requested to be Active on this ML.
For V5.2: the Variant Id. that the Local Exchange (LE)
requested to be Active.
128=none."
::= {v51MlEntry 4}
v51MlProtocolState OBJECT-TYPE
SYNTAX INTEGER
{
sysStartUp (1),
waitForVarId (2),
activatePstn (3),
restart1 (4),
inService (5),
restart2 (6),
restart3 (7),
waitV5Init (8),
switchOver (9),
ctrlDataLinkRel1 (10),
ctrlDataLinkRel2 (11),
ctrlDataLinkRel3 (12),
outOfService (13),
waitE1Reports (14),
waitL2StartUp (15),
waitLinkId (16),
waitRestart (17),
notDefined (18)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Protocol State of the ML Active Variant.
- sysStartUp - an Establish request arrived to the V5.1 interface.
- waitForVarId - the variant and the Interface Id were requested
during the system start-up procedure.
- activatePstn - activation of the PSTN Data Link was requested
during the system start-up procedure.
- restart1 - the PSTN restart procedure is in process.
- inService - the V5.1 interface is IN SERVICE.
- restart2 - the V5.1 is in AN5 state (sends restart complete
to all PSTN protocols and changes status to In-Service).
- restart3 - the V5.1 is in AN6 state (sends restart complete
to all PSTN protocols and changes status to In-Service).
- waitV5Init - this state is entered when the system's management is in
In-Service state, Switch to a new Variant is received
and V5.1 interface will not be restarted.
- switchOver - this state is entered when the system's management is in
In-Service state, Switch to a new Variant is received
and V5.1 interface will be restarted.
- ctrlDataLinkRel1 - this state is entered when the system's management is in
In-Service state and Release Indication is received.
Timer TC1 is running in this state.
- ctrlDataLinkRel2 - this state is entered on reception of Release-Indication
in 'restart3' state.
- outOfService - the V5.1 interface is Out-of-Service.
- notDefined - V5.1 is not defined for this interface."
::= {v51MlEntry 5}
v51MlUserActiveVarReq OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User Request to turn a certain Variant of the ML, to Active.
This object specifies the Variant Id. requested by user to be Active.
User's request is not always accepted."
::= {v51MlEntry 6}
v51MlDeleteVarReq OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For V5.1: User Request to Delete a certain Variant of the ML.
For V5.2: User Request to Delete a certain Variant
This object specifies the Variant Id. requested by user to be Delete.
User's request will not be accepted if the required Variant Id is Active
or during Reprovision process.
This object is supported only up to MP R9."
::= {v51MlEntry 7}
v51MlSaveVariant OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User Command to Save the TmpCnfg Variant data to a certain Variant Id of
the selected ML, in Current Cnfg. The value of this object specifies
the target Variant Id.
The data transferred should be:
- for V5.1: v51VarTable and v51VarCnfgTable parameters.
- for V5.2: v51VarTable, v51VarCnfgTable and v51VarCchTable parameters.
Upon Set command, the MUX will initiate a Sanity-Check process first:
- If successful, the actual transfer will be performed.
- If warnings are detected, the user will have to perform the command
again to confirm the operation.
- If errors are detected, transfer will NOT be performed.
This object is supported only up to MP R9."
::= {v51MlEntry 8}
v51MlReadVariant OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User Command to Read data from a certain Variant Id of the selected ML,
(in Current Cnfg) to the TmpCnfg. The value of this object specifies
the source Variant Id.
The data transferred should be:
- for V5.1: v51VarTable and v51VarCnfgTable parameters.
- for V5.2: v51VarTable, v51VarCnfgTable and v51VarCchTable parameters.
The operation is valid only on existing Variants of the ML.
This object is supported only up to MP R9."
::= {v51MlEntry 9}
v51MlDeactivateVar OBJECT-TYPE
SYNTAX Integer32 (0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User Request to Deactivate a certain Variant of the ML.
This object specifies the Variant Id. requested by user to be Deactivated.
User can deactivate a variant having Active Request status or Active
status. Deactivating the variant having Active Status wil stop the V5.1
operations on this link (for V5.2 it will stop completely the V5 activity)."
::= {v51MlEntry 10}
--ML Cnfg Table
v51MlCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF V51MlCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { v51MlCnfg 1}
v51MlCnfgEntry OBJECT-TYPE
SYNTAX V51MlCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table v51MlCnfgTable."
INDEX {v51MlCnfgIdx, v51MlCnfgSltIdx, v51MlCnfgPrtIdx}
::= { v51MlCnfgTable 1}
V51MlCnfgEntry ::=
SEQUENCE {
v51MlCnfgIdx Integer32,
v51MlCnfgSltIdx INTEGER,
v51MlCnfgPrtIdx Integer32,
v51MlCnfgIfId Integer32,
v51MlCnfgStartupMode INTEGER,
v51MlCnfgReprovision INTEGER,
v51MlCnfgUnblockIoPorts INTEGER,
v51MlCnfgRestartComplete INTEGER,
v51MlCnfgV52Application INTEGER
}
v51MlCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg being accessed.
1..10 = Current Cnfg (data will be the same for all Current
Configurations)
255 = TmpCnfg."
::= {v51MlCnfgEntry 1}
v51MlCnfgSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot Index.
For V5.2 this index will be notApplicable(255)."
::= {v51MlCnfgEntry 2}
v51MlCnfgPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number of the ML having
V5 interface.
Valid values: exPrt1 (1)..exPrt4 (4), inPrt1(101)..inPrt4(104)
NA=255 (for V5.2 only)."
::= {v51MlCnfgEntry 3}
v51MlCnfgIfId OBJECT-TYPE
SYNTAX Integer32 (0..99999999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"V5.1 Interface Id."
::= {v51MlCnfgEntry 4}
v51MlCnfgStartupMode OBJECT-TYPE
SYNTAX INTEGER
{
sync (2),
async (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Startup Mode."
::= {v51MlCnfgEntry 5}
v51MlCnfgReprovision OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reprovision Support.
- no : no reprovision support (=default)
- yes: reprovision is supported."
::= {v51MlCnfgEntry 6}
v51MlCnfgUnblockIoPorts OBJECT-TYPE
SYNTAX INTEGER
{
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Unblock IO Ports on Startup.
- disabled - disable sending Unblock request on restart
- enabled - request unblock of all IO ports ON RESTART (=default)."
::= {v51MlCnfgEntry 7}
v51MlCnfgRestartComplete OBJECT-TYPE
SYNTAX INTEGER
{
uponLeRestart (2),
uponPstnProtocolAck (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send Restart Complete.
- uponLeRestart - after receiving restart from the other side.
- uponPstnProtocolAck - after receiving restart ack from PSTN
protocol (=default)."
::= {v51MlCnfgEntry 8}
v51MlCnfgV52Application OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
endPoint (3),
exchangePoint (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The V5.2 Application of the Mux.
notApplicable - for Agents that don't support this object.
none - V5.2 is not used in the Mux.
endPoint - this V5.2 Application transfers voice of Analog Voice
and ISDN cards of the Mux, to/from V5.2 Local Exchange.
exchangePoint - this V5.2 Application exchanges voice of ML cards (coming
from other devices) to/from V5.2 Local Exchange."
::= {v51MlCnfgEntry 9}
--V5.1 Access port tables
v51IoCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF V51IoCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { v51AccessPort 1}
v51IoCnfgEntry OBJECT-TYPE
SYNTAX V51IoCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table v51IoCnfgTable."
INDEX {v51IoCnfgIdx, v51IoCnfgSltIdx, v51IoCnfgPrtIdx}
::= { v51IoCnfgTable 1}
V51IoCnfgEntry ::=
SEQUENCE {
v51IoCnfgIdx Integer32,
v51IoCnfgSltIdx INTEGER,
v51IoCnfgPrtIdx Integer32,
v51IoCnfgSType INTEGER,
v51IoCnfgFType INTEGER,
v51IoCnfgPType INTEGER
}
v51IoCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg being accessed.
1..10 = Current Cnfg (data will be the same for all Current
Configurations)
255 = TmpCnfg."
::= {v51IoCnfgEntry 1}
v51IoCnfgSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot Index"
::= {v51IoCnfgEntry 2}
v51IoCnfgPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number of the Io having
V5 interface.
Valid values: exPrt1 (1)..exPrt16 (16)"
::= {v51IoCnfgEntry 3}
v51IoCnfgSType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if S Type Signaling will be used by this ISDN port
(yes/no).
notApplicable - for PSTN ports."
::= {v51IoCnfgEntry 4}
v51IoCnfgFType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if F Type Signaling will be used by this ISDN port
(yes/no).
notApplicable - for PSTN ports."
::= {v51IoCnfgEntry 5}
v51IoCnfgPType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if P Type Signaling will be used by this ISDN port
(yes/no).
notApplicable - for PSTN ports."
::= {v51IoCnfgEntry 6}
-- Traps
--NOTIFICATIONS
v51IfEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for the V5."
::= { v51If 0 }
activeVariantTrap NOTIFICATION-TYPE
OBJECTS { v51MlCurrActiveVar }
STATUS current
DESCRIPTION
"This trap is sent when the Active Variant of a Link is changed (that
includes the case when a user performs Save to the Variant that is Active)."
::= { v51IfEvents 1 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\voip.txt
--
-- --------------------------------------------------------------------------------------
--Title: RAD's Voice Over IP MIB
--By: Liora Gafni
--Date : 28-Sep-99
--Description: This MIB contains parameters that were not defined in the ITU H.341 MIB
-- and are required for RAD products.
--
--Last Update: 07/09/2006
--By: Shay Harari
--File: v:\doc\rdv\mib\ver530\voip.txt
-- --------------------------------------------------------------------------------------
--IMPORTS
-- enterprises FROM SNMPv2-SMI
-- DisplayString FROM SNMPv2-TC
-- IpAddress FROM SNMPv2-SMI
-- OCTET STRING FROM SNMPv2-TC
-- OBJECT-TYPE FROM RFC1212
-- TAddress FROM SNMPv2-TC
-- MmTAddressTag,MmEndpointID,
-- MmAliasAddress,MmH323EndpointType,
-- MmGatekeeperID,MmGlobalIdentifier FROM MULTI-MEDIA-MIB-TC;
--wanGen OBJECT IDENTIFIER ::= {radWan 1} (see mpmx.txt)
voipWanGen OBJECT IDENTIFIER ::= {wanGen 7} --(see mpmx.txt)
voipWanGenEvents OBJECT IDENTIFIER ::= {voipWanGen 0}
-- VOIP Card Configuration
voipCardConfig OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object determines the VOIP card configuration.
Bit 0 (LSB): if 1 - a GK exists. If 0 - no GK exists in this card.
The other bits may be used in the future."
::= { voipWanGen 1 }
-- GK General Parameters table
gkGenTable OBJECT-TYPE
SYNTAX SEQUENCE OF GkGenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"General parameters for the VOIP GateKeeper."
::= { voipWanGen 2 }
gkGenEntry OBJECT-TYPE
SYNTAX GkGenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table gkGenTable."
INDEX {ifIndex}
::= { gkGenTable 1}
GkGenEntry ::=
SEQUENCE {
gkGenCallMode INTEGER,
gkGenMaxConnections Integer32,
gkGenDefaultDistance Integer32,
gkGenOutOfZoneDist Integer32,
gkGenCallAcceptPolicy INTEGER,
gkGenIrqInterval Integer32,
gkGenQ931Port Integer32,
gkGenRasPort Integer32,
gkGenRegPolicy INTEGER,
gkGenZoneId OCTET STRING
}
gkGenCallMode OBJECT-TYPE
SYNTAX INTEGER
{
direct (2),
routed (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameters shows whether the calls will go through the GK (routed) or
whether the calls will be direct from Endpoint to Endpoint without involving
the GK (direct)."
::= {gkGenEntry 1}
gkGenMaxConnections OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"MAX no. of connections enabled by the GK to take place simultaneously.
If the MAX no. of calls is exceeded, a busy signal will be returned."
::= {gkGenEntry 2}
gkGenDefaultDistance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Distance allowed for endpoints that are registered dynamically."
::= {gkGenEntry 3}
gkGenOutOfZoneDist OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Distance allowed for an out of zone endpoint that is making a call
through the gatekeeper."
::= {gkGenEntry 4}
gkGenCallAcceptPolicy OBJECT-TYPE
SYNTAX INTEGER
{
acceptAll (2),
registeredOnly (3),
predefinedOnly (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the policy concerning the incoming phone calls.
The importance of this parameter is for bidding and security matters.
Accept All - all the incoming calls are accepted.
Registered Only - the calls are accepted from the predefined endpoints only,
which are endpoints that have previously registered with the gatekeeper.
Predefined Only - with this policy only the calls from the statically
registered endpoints can be accepted."
::= {gkGenEntry 5}
gkGenIrqInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In order for the Gatekeeper to determine if an endpoint is turned off,
or has otherwise entered a failure mode, the Gatekeeper may use the Information
Request (IRQ) to poll the endpoints at the certain interval (in seconds).
THE IRQ INTERVAL controls the frequency the gk sends IRQ messages.
This message is sent to all on-line endpoints registered as dynamic in order
to verify they are really on-line. This is done to detect terminals that
shut off without sending the required URQ message that notifies the gk that
they are no longer on-line.
Endpoints failing to respond too many times have their dynamic properties
unregistered. Choosing the desired interval should take into account the
following factors :
IRQ messages add to the traffic already present over the network and the
shorter the interval the more IRQ messages will be sent. On the other hand the
longer the delay the longer it will take for the gk to detect dynamic
registrations that have ceased to actually be on-line. Note that the
IRQ interval relates to each endpoint and the actual number of the IRQ messages
the gk will create should be multiplied by the number of endpoints
registered dynamically."
::= {gkGenEntry 6}
gkGenQ931Port OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Q.931 Port no."
::= {gkGenEntry 7}
gkGenRasPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RAS Port no."
::= {gkGenEntry 8}
gkGenRegPolicy OBJECT-TYPE
SYNTAX INTEGER
{
acceptAll (2),
predefinedOnly (3),
registrationReject (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Policy of dynamic registrations in the Gatekeeper.
The GK will act according to the following policies:
Accept All - The GK will enable all requesting endpoints to register dynamically.
Predefined Only - The GK will enable registration of endpoints that were registered
previously via static registration.
Registration Reject - No endpoint may register dynamically."
::= {gkGenEntry 9}
gkGenZoneId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Zone Identifier: 1 or 2 digits, (0-9)(1-9)."
::= {gkGenEntry 10}
-- GK Endpoints Table
gkEndpTable OBJECT-TYPE
SYNTAX SEQUENCE OF GkEndpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table containing the Endpoints that are registered (statically & Dynamically)
with the current GK."
::= { voipWanGen 3 }
gkEndpEntry OBJECT-TYPE
SYNTAX GkEndpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table gkEndpTable."
INDEX {ifIndex,
gkEndpAliasTag,
gkEndpAlias}
::= { gkEndpTable 1}
GkEndpEntry ::=
SEQUENCE {
gkEndpAliasTag MmAliasTag,
gkEndpAlias MmAliasAddress,
gkEndpRowStatus RowStatus,
gkEndpAddressTag MmTAddressTag,
gkEndpAddress TAddress,
gkEndpID MmEndpointID,
gkEndpType MmH323EndpointType,
gkEndpQ931Port Integer32,
gkEndpDistance Integer32,
gkEndpRegMode INTEGER,
gkEndpSetOnline INTEGER,
gkEndpStatus INTEGER
}
gkEndpAliasTag OBJECT-TYPE
SYNTAX MmAliasTag
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alias Tag of the Endpoint."
::= {gkEndpEntry 1}
gkEndpAlias OBJECT-TYPE
SYNTAX MmAliasAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alias of the Endpoint."
::= {gkEndpEntry 2}
gkEndpRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of the entry. This object is required to create
or delete rows remotely by a manager. "
::= {gkEndpEntry 3}
gkEndpAddressTag OBJECT-TYPE
SYNTAX MmTAddressTag
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Address Tag of Endpoint."
::= {gkEndpEntry 4}
gkEndpAddress OBJECT-TYPE
SYNTAX TAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Address of Endpoint."
::= {gkEndpEntry 5}
gkEndpID OBJECT-TYPE
SYNTAX MmEndpointID
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Endpoint Identifier."
::= {gkEndpEntry 6}
gkEndpType OBJECT-TYPE
SYNTAX MmH323EndpointType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter shows whether the current endpoint is a GW or Terminal or
any other type of H.323 endpoint."
::= {gkEndpEntry 7}
gkEndpQ931Port OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Q.931 Port no."
::= {gkEndpEntry 8}
gkEndpDistance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Distance from the current endpoint to the GateKeeper with which it is
Registered."
::= {gkEndpEntry 9}
gkEndpRegMode OBJECT-TYPE
SYNTAX INTEGER
{
dynamic (2),
static (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter shows whether the Endpoint Registered Dynamically or Statically."
::= {gkEndpEntry 10}
gkEndpSetOnline OBJECT-TYPE
SYNTAX INTEGER
{
uponDynamicReg (2),
always (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter shows whether the endpoint will always be online or whether it
will be on line upon Dynamic Registration only."
::= {gkEndpEntry 11}
gkEndpStatus OBJECT-TYPE
SYNTAX INTEGER
{
online (2),
offline (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter shows whether the endpoint is currently online."
::= {gkEndpEntry 12}
-- GK Neighbors table
gkNeighbTable OBJECT-TYPE
SYNTAX SEQUENCE OF GkNeighbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of GateKeepers that are Neighbors of the current Gatekeeper."
::= { voipWanGen 4 }
gkNeighbEntry OBJECT-TYPE
SYNTAX GkNeighbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table gkNeighbTable."
INDEX {ifIndex,
gkNeighbAddressTag,
gkNeighbAddress}
::= { gkNeighbTable 1}
GkNeighbEntry ::=
SEQUENCE {
gkNeighbAddressTag MmTAddressTag,
gkNeighbAddress TAddress,
gkNeighbRowStatus RowStatus,
gkNeighbLeadingAlias MmAliasAddress,
gkNeighbDistance Integer32,
gkNeighbDescription MmGatekeeperID
}
gkNeighbAddressTag OBJECT-TYPE
SYNTAX MmTAddressTag
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tag of GK or GW address."
::= {gkNeighbEntry 1}
gkNeighbAddress OBJECT-TYPE
SYNTAX TAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Address of GK or GW."
::= {gkNeighbEntry 2}
gkNeighbRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of the entry. This object is required to create
or delete rows remotely by a manager. "
::= {gkNeighbEntry 3}
gkNeighbLeadingAlias OBJECT-TYPE
SYNTAX MmAliasAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the Leading Alias Address (Zone Prefix) that will be dialed in order to reach
the specific neighbor."
::= {gkNeighbEntry 4}
gkNeighbDistance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Distance between the local GateKeeper and the Neighbor GateKeeper."
::= {gkNeighbEntry 5}
gkNeighbDescription OBJECT-TYPE
SYNTAX MmGatekeeperID
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ASCII String Description for identifying the Neighbor."
::= {gkNeighbEntry 6}
-- GW General Parameters table
gwGenTable OBJECT-TYPE
SYNTAX SEQUENCE OF GwGenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"General parameters for the VOIP GateWay."
::= { voipWanGen 5 }
gwGenEntry OBJECT-TYPE
SYNTAX GwGenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table gwGenTable."
INDEX {ifIndex}
::= { gwGenTable 1}
GwGenEntry ::=
SEQUENCE {
gwGenGwId MmEndpointID,
gwGenQ931Port Integer32,
gwGenRasPort Integer32,
gwGenMode INTEGER,
gwGenVoipExtension Integer32,
gwGenRemGwAddress TAddress,
gwGenMaxConnections Integer32,
gwGenTOS OCTET STRING,
gwGenBackupGkAddr TAddress,
gwGenTimeToRegister Integer32
}
gwGenGwId OBJECT-TYPE
SYNTAX MmEndpointID
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A character string of up to 20 characters identifying the gateway."
::= {gwGenEntry 1}
gwGenQ931Port OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Q.931 port no. of the Gateway."
::= {gwGenEntry 2}
gwGenRasPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The RAS port no. of the Gateway."
::= {gwGenEntry 3}
gwGenMode OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
cvsIp (3),
standard (4),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"GW Mode:
disable - The GW is not activated.
cvsIp - CVS is a Compressed Voice System.
The GW will compress voice calls at a ratio of
16 to 1. 16 time slots of E1/T1 will be compressed into
1 E1/T1 time slot. When this mode is used the Gateway can
communicate directly with another Gateway without a Gatekeeper.
standard - This mode includes a Gateway & a Gatekeeper."
::= {gwGenEntry 4}
gwGenVoipExtension OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the extension number of the VOIP protocol.
It is used for the Voice card to identify the calls made through the VoIP card.
The user may choose an arbitrary value for this field, the only restriction is that
there must be no other entity registered with the same extension number."
::= {gwGenEntry 5}
gwGenRemGwAddress OBJECT-TYPE
SYNTAX TAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the remote gateway address (IP + port). It is important for gateway
to gateway connection."
::= {gwGenEntry 6}
gwGenMaxConnections OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"MAX no. of connections enabled by the GW."
::= {gwGenEntry 7}
gwGenTOS OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Type of Service.
The BIT Format is consistent with the IP standard:
+-----+-----+-----+-----+-----+-----+-----+-----+
| | | |
| PRECEDENCE | TYPE OF SERVICE | 0 |
| | | |
+-----+-----+-----+-----+-----+-----+-----+-----+
0 1 2 3 4 5 6 7
At present, only 1 BYTE will be used, bits 0 (MSB) - 7 (LSB).
The precedence consists of 3 BITS (0-2):
111 - Network Control
110 - Internetwork Control
101 - CRITIC/ECP
100 - Flash Override
011 - Flash
010 - Immediate
001 - Priority
000 - Routine
The TOS values BITS (3-5):
Bit 3 is the Delay: 0 = Normal Delay, 1 = Low Delay.
Bit 4 is the Throughput: 0 = Normal Throughput, 1 = High Throughput.
Bit 5:is the Reliability: 0 = Normal Reliability, 1 = High Reliability.
Bits 6 & 7 are for future use and their current value is 0."
::= {gwGenEntry 8}
gwGenBackupGkAddr OBJECT-TYPE
SYNTAX TAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the backup gatekeeper address (IP + port).
When the backup GK is active, all the calls will be routed to it and it
will be responsible for their address translation.
The first GK address is defined in the standard H.341 MIB."
::= {gwGenEntry 9}
gwGenTimeToRegister OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The GW should register every 'Time to Register' seconds with the GK.
The 'Time to Register' range is from 0 to 900 seconds in intervals of 60 seconds.
0 means Never.
When the GK becomes active the Gateways that are up can register so that
the GK has an updated list of active Registered Gateways."
::= {gwGenEntry 10}
-- RAD's addition to h245ConfigurationTable
radH245ConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadH245ConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains information about H.245 configuration parameters.
It is a list of configuration parameter entries.
The number of entries equals to the number of H.245 stacks in a system."
::= { voipWanGen 6 }
radH245ConfigEntry OBJECT-TYPE
SYNTAX RadH245ConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"It contains objects that describe the H.245 configuration parameters."
INDEX { ifIndex }
::= { radH245ConfigTable 1 }
RadH245ConfigEntry ::=
SEQUENCE {
h245MaxJitter Integer32,
h245Tunneling INTEGER
}
h245MaxJitter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum peak to peak delivery (in miliseconds) of audio packets
to the transport layer that the transmitter shall cause."
::= {radH245ConfigEntry 1}
h245Tunneling OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable enables or disables the usage of Tunneling."
::= {radH245ConfigEntry 2}
-- RTP Multiplexing
rtpMultiplexTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtpMultiplexEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RTP Multiplexing table.
RTP Multiplexing: In IP telephony system, the addition of packet headers,
including IP, UDP and RTP headers, increases the header overhead, decreasing
efficient transmission. Also, because of large numbers of short voice
packets flowing into the network, Internet load increases, eventually
resulting in large delay and packet loss. RTP Multiplexing is a way to send
multiple RTP packets between a pair of Gateways, with a single
IP frame. This will reduces the header overhead and decreases delay by
enabling voice transmission with fewer packets."
::= { voipWanGen 7 }
rtpMultiplexEntry OBJECT-TYPE
SYNTAX RtpMultiplexEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table rtpMultiplexTable."
INDEX {ifIndex}
::= { rtpMultiplexTable 1}
RtpMultiplexEntry ::=
SEQUENCE {
rtpMultiplexedRtp INTEGER,
rtpMultiplexFrameSize Integer32,
rtpMultiplexInterval Integer32,
rtpMultiplexPcktRedundancy Integer32
}
rtpMultiplexedRtp OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
multiplexType1 (3),
multiplexType2 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RTP Multiplexing is a way to send multiple RTP packets with a single IP frame.
This will reduce the header overhead and decrease the delay by enabling
voice transmission with fewer packets.
The option of this field are:
Disable - No RTP Multiplexing.
multiplexType1 - medium level of compression for RTP multiplexing.
multiplexType2 - high level of compression for RTP multiplexing.
Using the High Compression algorithm is more efficient
but will cause the loss of some RTP header information.
If RTP statistics are important, the medium compression must be selected."
::= {rtpMultiplexEntry 1}
rtpMultiplexFrameSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the maximum size in Bytes of the multiplexed frame.
In some cases this must be limited to avoid IP fragmentation,
which makes the multiplexing useless, and can also decrease
the damage in case of the frame loss.
At present the size is 1500."
::= {rtpMultiplexEntry 2}
rtpMultiplexInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the maximum amout of time (msec.) between multiplexed frames
that are sent.
Legal values: 10-90 msec."
::= {rtpMultiplexEntry 3}
rtpMultiplexPcktRedundancy OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the the number of times each voice frame should be transmitted.
At present legal values are: 1-4."
::= {rtpMultiplexEntry 4}
-- Tariff
voipTariff OBJECT IDENTIFIER ::= {voipWanGen 8}
voipTariffServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipTariffServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"VoIP Tariff Server table."
::= { voipTariff 1 }
voipTariffServerEntry OBJECT-TYPE
SYNTAX VoipTariffServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table voipTariffServerTable."
INDEX {voipTariffServerCnfgIdx, voipTariffServerIdx}
::= { voipTariffServerTable 1}
VoipTariffServerEntry ::=
SEQUENCE {
voipTariffServerCnfgIdx Unsigned32,
voipTariffServerIdx Unsigned32,
voipTariffServerIpAddress IpAddress,
voipTariffServerPort Unsigned32
}
voipTariffServerCnfgIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Index of the Configuration (1..255) being
accessed ; Index=255 relates to the Temporary Configuration.
Set is allowed only to the Temporary Configuration."
::= { voipTariffServerEntry 1}
voipTariffServerIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Index of the Tariff Server being
accessed (1, 2)."
::= { voipTariffServerEntry 2}
voipTariffServerIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the IP Address of the Tariff Server."
::= { voipTariffServerEntry 3}
voipTariffServerPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the used TCP/UDP port of the Tariff Server."
::= { voipTariffServerEntry 4}
-- VoIP NOTIFICATIONS
voipTariffServerCommFail NOTIFICATION-TYPE
OBJECTS {voipTariffServerIpAddress, voipTariffServerPort}
STATUS current
DESCRIPTION
"This trap is sent when communication attempt with a Tariff Server failed."
::= { voipWanGenEvents 1 }
voipConfig OBJECT IDENTIFIER ::= { voipWanGen 9 }
voipSip OBJECT IDENTIFIER ::= { voipConfig 1 }
-- ----------------------------------
-- SIP (Session Initiation Protocol)
-- ----------------------------------
--
-- SIP Common Objects
--
voipSipCommon OBJECT IDENTIFIER ::= {voipSip 1}
voipSipCommonCfg OBJECT IDENTIFIER ::= {voipSipCommon 1}
radSipCommonCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadSipCommonCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SIP Common Configuration table.
This table contains the common configuration objects
applicable to all SIP entities."
::= { voipSipCommonCfg 1 }
radSipCommonCfgEntry OBJECT-TYPE
SYNTAX RadSipCommonCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row of SIP Common Configuration table."
INDEX { radSipCommonCfgIdx }
::= { radSipCommonCfgTable 1 }
RadSipCommonCfgEntry ::=
SEQUENCE {
radSipCommonCfgIdx Unsigned32,
radSipCommonCfgListenPort Unsigned32,
radSipCommonCfgRtpBaseUdpPort Unsigned32,
radSipCommonCfgRtpIpTos Unsigned32
}
radSipCommonCfgIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the table.
This object might represent the Configuration Index (1..100) being accessed;
Index=255 relates to the TmpCnfg.
For devices with multiple configurations, Set is permitted to TmpCnfg(255) only.
Not-Applicable = 1."
::= { radSipCommonCfgEntry 1 }
radSipCommonCfgListenPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the SIP Listening Port number."
::= { radSipCommonCfgEntry 2 }
radSipCommonCfgRtpBaseUdpPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the RTP Base UDP Port number."
::= { radSipCommonCfgEntry 3 }
radSipCommonCfgRtpIpTos OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the TOS byte value
that will be written in the IP header for RTP packets only."
::= { radSipCommonCfgEntry 4 }
--
-- SIP Server
--
voipSipServer OBJECT IDENTIFIER ::= {voipSip 2}
voipSipServerCfg OBJECT IDENTIFIER ::= {voipSipServer 1}
radSipRegCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadSipRegCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SIP Registrar Configuration table."
::= { voipSipServerCfg 1 }
radSipRegCfgEntry OBJECT-TYPE
SYNTAX RadSipRegCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row of SIP Registrar Configuration table."
INDEX { radSipRegCfgIdx, radSipRegIdx }
::= { radSipRegCfgTable 1 }
RadSipRegCfgEntry ::=
SEQUENCE {
radSipRegCfgIdx Unsigned32,
radSipRegIdx Unsigned32,
radSipRegActivation INTEGER,
radSipRegAddr SnmpAdminString, -- IP/URL address
radSipRegUdpPort Unsigned32,
radSipRegRenewalTimer Unsigned32,
radSipRegDomain SnmpAdminString,
radSipRegMode INTEGER,
radSipRegUserDefinition INTEGER,
radSipRegCallWithoutReg INTEGER,
radSipRegUserParams SnmpAdminString,
radSipRegRowStatus RowStatus
}
radSipRegCfgIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The first index of the table.
This object might represent the Configuration Index (1..100) being accessed;
Index=255 relates to the TmpCnfg.
For devices with multiple configurations, Set is permitted to TmpCnfg(255) only.
Not-Applicable = 1."
::= { radSipRegCfgEntry 1 }
radSipRegIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the Registrar Index."
::= { radSipRegCfgEntry 2 }
radSipRegActivation OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object allows the user to activate the Registrar.
If changed from enable(3) to disable(2) -
device will be disconnected from server (stop sending renewal messages).
If changed from disable(2) to enable(3) -
device will be connected to the server."
::= { radSipRegCfgEntry 3 }
radSipRegAddr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the Registrar's IP/URL Address."
::= { radSipRegCfgEntry 4 }
radSipRegUdpPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the Registration's Destination UDP Port number."
::= { radSipRegCfgEntry 5 }
radSipRegRenewalTimer OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the Registration's Renewal Timer, in seconds."
::= { radSipRegCfgEntry 6 }
radSipRegDomain OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the User Agent's Domain Name."
::= { radSipRegCfgEntry 7 }
radSipRegMode OBJECT-TYPE
SYNTAX INTEGER
{
gateway (1),
localEntries (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the Registration Mode:
gateway(1) - one registration for the device
localEntries(2) - number of registrations are defined according to
the number of local entries."
::= { radSipRegCfgEntry 8 }
radSipRegUserDefinition OBJECT-TYPE
SYNTAX INTEGER
{
gateway (1),
localEntries (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the User configuration:
gateway(1) - single user configuration for the device
localEntries(2) - different user configuration for each local entry.
This object is irrelevant when radSipRegMode = gateway(1)."
::= { radSipRegCfgEntry 9 }
radSipRegCallWithoutReg OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates whether a call is enabled without registration."
::= { radSipRegCfgEntry 10 }
radSipRegUserParams OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the User's parameters.
This object is irrelevant when radSipRegUserDefinition = localEntries(2)."
::= { radSipRegCfgEntry 11 }
radSipRegRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables the user to create/delete entries in this table."
::= { radSipRegCfgEntry 12 }
--
-- Network Routing table
--
voipNetRoutTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipNetRoutEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Network Routing table."
::= { voipConfig 2 }
voipNetRoutEntry OBJECT-TYPE
SYNTAX VoipNetRoutEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row of Network Routing table."
INDEX { voipNetRoutCfgIdx, voipNetRoutPrefix }
::= { voipNetRoutTable 1 }
VoipNetRoutEntry ::=
SEQUENCE {
voipNetRoutCfgIdx Unsigned32,
voipNetRoutPrefix SnmpAdminString,
voipNetRoutRowStatus RowStatus,
voipNetRoutMinDigits Unsigned32,
voipNetRoutMaxDigits Unsigned32,
voipNetRoutAddr SnmpAdminString, -- IP/URL address
voipNetRoutUdpPort Unsigned32,
voipNetRoutOutboundProxySupport INTEGER,
voipNetRoutOutboundProxyAddr SnmpAdminString, -- IP/URL address
voipNetRoutOutboundProxyUdpPort Unsigned32
}
voipNetRoutCfgIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The first index of the table.
This object might represent the Configuration Index (1..100) being accessed;
Index=255 relates to the TmpCnfg.
For devices with multiple configurations, Set is permitted to TmpCnfg(255) only.
Not-Applicable = 1."
::= { voipNetRoutEntry 1 }
voipNetRoutPrefix OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the prefix number.
This prefix can include non-decimal digits, such as * or #.
The default route will be represented by an empty prefix."
::= { voipNetRoutEntry 2 }
voipNetRoutRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables the user to create/delete entries in this table."
::= { voipNetRoutEntry 3 }
voipNetRoutMinDigits OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the Minimum number of digits."
::= { voipNetRoutEntry 4 }
voipNetRoutMaxDigits OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the Maximum number of digits."
::= { voipNetRoutEntry 5 }
voipNetRoutAddr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the route's IP/URL Address."
::= { voipNetRoutEntry 6 }
voipNetRoutUdpPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the route's destination UDP port number."
::= { voipNetRoutEntry 7 }
voipNetRoutOutboundProxySupport OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates whether the Outbound Proxy is supported."
::= { voipNetRoutEntry 8 }
voipNetRoutOutboundProxyAddr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the Outbound Proxy's IP/URL Address."
::= { voipNetRoutEntry 9 }
voipNetRoutOutboundProxyUdpPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the Outbound Proxy UDP port number."
::= { voipNetRoutEntry 10 }
--
-- Numbering Manipulation table
--
voipNumManipTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipNumManipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Numbering Manipulation table."
::= { voipConfig 3 }
voipNumManipEntry OBJECT-TYPE
SYNTAX VoipNumManipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row of Numbering Manipulation table."
INDEX { voipNumManipCfgIdx, voipNumManipTypeId, voipNumManipRuleIdx }
::= { voipNumManipTable 1 }
VoipNumManipEntry ::=
SEQUENCE {
voipNumManipCfgIdx Unsigned32,
voipNumManipTypeId Unsigned32,
voipNumManipRuleIdx Unsigned32,
voipNumManipRowStatus RowStatus,
voipNumManipOriginalNumber Unsigned32,
voipNumManipNewNumber Unsigned32
}
voipNumManipCfgIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The first index of the table.
This object might represent the Configuration Index (1..100) being accessed;
Index=255 relates to the TmpCnfg.
For devices with multiple configurations, Set is permitted to TmpCnfg(255) only.
Not-Applicable = 1."
::= { voipNumManipEntry 1 }
voipNumManipTypeId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the Numbering Manipulation's Type ID.
Type ID represents a unique Type, which can be different for each device.
For Vmux-300 devices -
Type ID Manipulated Number Call direction
--------------------------------------------------------------
1 = Dialed (destination) Incoming (Network to Local)
2 = Dialed (destination) Outgoing (Local to Network)
3 = Dialing (source) Incoming (Network to Local)
4 = Dialing (source) Outgoing (Local to Network)
For example:
Type ID 1 represents a manipulation on a Dialed number
for a call that in its way from the Network towards the Local."
::= { voipNumManipEntry 2 }
voipNumManipRuleIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the Rule index."
::= { voipNumManipEntry 3 }
voipNumManipRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables the user to create/delete entries in this table."
::= { voipNumManipEntry 4 }
voipNumManipOriginalNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the original number (before manipulation)."
::= { voipNumManipEntry 5 }
voipNumManipNewNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the new number (after manipulation)."
::= { voipNumManipEntry 6 }
--
-- Supplementary Services
--
voipService OBJECT IDENTIFIER ::= { voipConfig 4 }
voipServiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Services table."
::= { voipService 1 }
voipServiceEntry OBJECT-TYPE
SYNTAX VoipServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row of Service table."
INDEX { voipServiceCfgIdx, voipServicePrtIdx, voipServiceType }
::= { voipServiceTable 1 }
VoipServiceEntry ::=
SEQUENCE {
voipServiceCfgIdx Unsigned32,
voipServicePrtIdx Unsigned32,
voipServiceType INTEGER,
voipServiceSupport INTEGER,
voipServiceCallForwardType INTEGER,
voipServiceCallForwardPhoneNo SnmpAdminString,
voipServiceCallForwardNoReplyTimeout Unsigned32,
voipServiceCallerIdType INTEGER,
voipServiceCallerIdDisplayString SnmpAdminString
}
voipServiceCfgIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The first index of the table.
This object might represent the Configuration Index (1..100) being accessed;
Index=255 relates to the TmpCnfg.
For devices with multiple configurations, Set is permitted to TmpCnfg(255) only.
Not-Applicable = 1."
::= { voipServiceEntry 1 }
voipServicePrtIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the Port Index.
When irrelevant, value will be 1."
::= { voipServiceEntry 2 }
voipServiceType OBJECT-TYPE
SYNTAX INTEGER
{
callForward (1),
callTransfer (2),
callerIdRestriction (3),
callHold (4)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the Service's Type."
::= { voipServiceEntry 3 }
voipServiceSupport OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the Service's support."
::= { voipServiceEntry 4 }
voipServiceCallForwardType OBJECT-TYPE
SYNTAX INTEGER
{
noForward (1),
unconditional (2),
noReply (3),
busy (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the Call Forward Type.
It is relevant only for voipServiceType = callForward(1)."
::= { voipServiceEntry 5 }
voipServiceCallForwardPhoneNo OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the Phone Number to be forwarded.
It is relevant only for voipServiceType = callForward(1)."
::= { voipServiceEntry 6 }
voipServiceCallForwardNoReplyTimeout OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the No Reply Timeout in seconds.
It means how many seconds with no reply should pass
so that this period of time will be considered as No Reply.
It is relevant only for voipServiceType = callForward(1)."
::= { voipServiceEntry 7 }
voipServiceCallerIdType OBJECT-TYPE
SYNTAX INTEGER
{
noRestriction (1),
restrictAllCalls (2),
restrictNextCall (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the Caller ID Type.
It is relevant only for voipServiceType = callerIdRestriction(3)."
::= { voipServiceEntry 8 }
voipServiceCallerIdDisplayString OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the string that should be displayed
when no restriction is applied.
It is relevant only for voipServiceType = callerIdRestriction(3)."
::= { voipServiceEntry 9 }
voipFeatureTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipFeatureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Feature table."
::= { voipService 2 }
voipFeatureEntry OBJECT-TYPE
SYNTAX VoipFeatureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row of Feature table."
INDEX { voipFeatureCfgIdx, voipFeaturePrtIdx, voipFeatureType }
::= { voipFeatureTable 1 }
VoipFeatureEntry ::=
SEQUENCE {
voipFeatureCfgIdx Unsigned32,
voipFeaturePrtIdx Unsigned32,
voipFeatureType INTEGER,
voipFeatureKeypadString SnmpAdminString
}
voipFeatureCfgIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The first index of the table.
This object might represent the Configuration Index (1..100) being accessed;
Index=255 relates to the TmpCnfg.
For devices with multiple configurations, Set is permitted to TmpCnfg(255) only.
Not-Applicable = 1."
::= { voipFeatureEntry 1 }
voipFeaturePrtIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the Port Index.
When irrelevant, value will be 1."
::= { voipFeatureEntry 2 }
voipFeatureType OBJECT-TYPE
SYNTAX INTEGER
{
callForwardUnconditional (1),
callForwardNoReply (2),
callForwardBusy (3),
callForwardDeactivation (4),
callTransfer (5),
callerIdRestrictNextCall (6),
callerIdRestrictAllCalls (7),
callerIdRestrictDeactivation (8)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the Feature's Type."
::= { voipFeatureEntry 3 }
voipFeatureKeypadString OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the Feature's Keypad string.
This string is a combination of digits, * and #."
::= { voipFeatureEntry 4 }
--
-- NAT Traversal
--
voipNatTraversal OBJECT IDENTIFIER ::= { voipConfig 5 }
voipNatTravIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the NAT IP Address, given to the device (e.g. Vmux)
It is used only in case of static NAT."
::= { voipNatTraversal 1 }
voipNatTravStun OBJECT IDENTIFIER ::= { voipNatTraversal 2 } -- STUN = Simple Traversal of UDP through NATs
voipNatTravStunServerAddress OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the STUN Server's IP/URL Address."
::= { voipNatTravStun 1 }
voipNatTravStunBaseUdpPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the STUN Base UDP Port number."
::= { voipNatTravStun 2 }
voipNatTravStunSipInterval OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the STUN Keep-Alive time interval (in seconds),
for maintaining the SIP signaling port and IP address."
::= { voipNatTravStun 3 }
voipNatTravStunRtpInterval OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the STUN Keep-Alive time interval (in seconds),
for maintaining the RTP stream ports and IP addresses."
::= { voipNatTravStun 4 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\ipmux.txt
--
-- File: Ipmux.txt
ip2If OBJECT IDENTIFIER ::= { diverseIfWanGen 7 }
-- ip2If Configuration table
ip2IfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ip2IfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Channels Configuration Table."
::= { ip2If 1 }
ip2IfEntry OBJECT-TYPE
SYNTAX Ip2IfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Application layer configuration per link"
INDEX { ip2IfChannelIndex }
::= { ip2IfTable 1 }
Ip2IfEntry ::=
SEQUENCE {
ip2IfChannelIndex Integer32,
ip2IfRowStatus RowStatus,
ip2IfOperStatus INTEGER,
ip2IfAdminStatus INTEGER,
ip2IfDestAddr IpAddress,
ip2IfNextHop IpAddress,
ip2IfDestPort Integer32,
ip2IfMacAddr MacAddress,
ip2IfJitterBuffer Integer32,
ip2IfTos Integer32,
ip2IfTDMBytesInFrame Integer32,
ip2IfVlanSupport INTEGER,
ip2IfVlanIdentifier Integer32,
ip2IfVlanFramePriority Integer32,
ip2IfExitPort INTEGER,
ip2IfVoiceOos OCTET STRING,
ip2IfDataOos OCTET STRING,
ip2IfBundleUsage Integer32,
ip2IfOAM OCTET STRING,
ip2IfTDMoIpMode INTEGER,
ip2IfTimeElapsed Integer32,
ip2IfValidIntervals Integer32,
ip2IfFarEndType INTEGER,
ip2IfRdnState INTEGER,
ip2IfSourceAddr IpAddress,
ip2IfBandWidth Integer32,
ip2IfMeasuredSilence Integer32,
ip2IfPayloadType INTEGER,
ip2IfProtocolVersion INTEGER,
ip2IfTdmBackUpNextHop IpAddress,
ip2IfOosTxEnable INTEGER,
ip2IfConnCheckPktFrequency Integer32,
ip2IfConnPktTimeOutCycles Integer32,
ip2IfMfRelay INTEGER,
ip2IfTxGain Integer32,
ip2IfSuperTandem INTEGER,
ip2IfSrcPort Integer32,
ip2IfModemCalls INTEGER,
ip2IfMinPulseWidth Integer32,
ip2IfMinPowerLevel Integer32,
ip2IfEchoCanceler INTEGER,
ip2IfCodingLaw INTEGER,
ip2IfCustomToneDetect INTEGER,
ip2IfCallerIdDelay Integer32,
ip2IfConnectivityMode INTEGER,
ip2IfClockSourceEnable INTEGER,
ip2IfNetworkType INTEGER,
ip2IfMplsRxLabelEnable INTEGER,
ip2IfMplsRxLabel Integer32,
ip2IfMplsTxLabelEnable INTEGER,
ip2IfMplsTxLabel Integer32,
ip2IfMplsTxExpBits Integer32,
ip2IfMfcSpoofing INTEGER,
ip2IfToneAckInterval Integer32,
ip2IfNextHopType INTEGER,
ip2IfNoiseLevelForVAD INTEGER,
ip2IfClockPreferences INTEGER,
ip2IfConnectionMode INTEGER,
ip2IfRingBack INTEGER,
ip2IfReversePolarity INTEGER,
ip2IfPulseMeter INTEGER,
ip2IfPulseMeterFreq INTEGER,
ip2IfPulseMeterPeriod Integer32,
ip2IfOnHookDetect INTEGER,
ip2IfComfortNoiseGen INTEGER,
ip2IfExitChannel Integer32,
ip2IfMaxVBDModemCalls Integer32,
ip2IfMaxRelayModemCalls Integer32,
ip2IfCustomToneFrequency INTEGER,
ip2IfVadMethod INTEGER,
ip2IfRxGain Integer32,
ip2IfCallerIDType INTEGER,
ip2IfPeerAddrType INTEGER,
ip2IfVbdRate INTEGER,
ip2IfDtmfDetection INTEGER,
ip2IfNlpCutoffLevel Unsigned32,
ip2IfDtdErlRatioCutoffQ3 Unsigned32,
ip2IfCASRedundancy INTEGER,
ip2IfBundleSensitivity INTEGER,
ip2IfOAMBundleIdent INTEGER,
ip2IfMaxTxQueue Unsigned32,
ip2IfMaxGprsTxQueue Unsigned32,
ip2IfV23HD INTEGER,
ip2IfModemProtocolMode OCTET STRING,
ip2IfCdisCngDetectionTime Unsigned32,
ip2IfSuperTandemBitMask OCTET STRING,
ip2IfVbdSwitchbackTime Unsigned32,
ip2IfCallerIdTxGain Integer32,
ip2IfCallerIdRxGain Integer32,
ip2IfUdpMuxMethod INTEGER,
ip2IfCallerIdDetection INTEGER,
ip2IfWap INTEGER,
ip2IfSignalingOos INTEGER
}
ip2IfChannelIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The channel index, which is actualy the bundle ID."
::= { ip2IfEntry 1 }
ip2IfRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter allows NMS to create/delete entries of this table."
::= { ip2IfEntry 2 }
ip2IfOperStatus OBJECT-TYPE
SYNTAX INTEGER {
down (2),
up (3),
disabled (4),
remoteFail (5),
localFail (6),
unavailable (7),
validationFail (8),
standby (9),
tdmFail (10),
hwMismatch (11)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual link status.
remoteFail - No Rx.
localFail - No Tx.
unavailable - No echo replay or replay with invalid code or when connection is in Test state.
valiodationFail - Connection is in not valid state.
standby - offline (can be in pre-sync mode).
tdmFail - oper status is down cause of failure in the tdm.
hwMismatch - the bundle exists on a card that is not installed or has a different
type than the programmed card."
::= { ip2IfEntry 3 }
ip2IfAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
down (2),
up (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The desired state of the link."
::= { ip2IfEntry 4 }
ip2IfDestAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The destination IP address."
::= { ip2IfEntry 5 }
ip2IfNextHop OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The next hop to which the frame should be sent.
Default value - 0.0.0.0.
Upon setting the default value the frame is sent
to the default Gateway."
::= { ip2IfEntry 6 }
ip2IfDestPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The destination Bundle at the far-end device."
::= { ip2IfEntry 7 }
ip2IfMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Destination MAC address of the next hop or
destination station."
::= { ip2IfEntry 8 }
ip2IfJitterBuffer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum cell arrival jitter in 10 usec that the
reassembly process will tolerate in the cell stream,
without producing errors on the CBR service interface.
For KM2100:
KML.11 - The range that will be used is 3...300 msec
in steps of 1 msec.
For Vmux:
The range that will be used is 20...100 msec
in steps of 10 msec."
::= { ip2IfEntry 9 }
ip2IfTos OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The TOS (Type of Service) value: 0..255.
In Vmux-2100/110 devices versions 3.1 and up, in Vmux-210 and in Vmux-4x0:
LSB 8 bits - 00 00 00 XX will be used for Signaling packets TOS.
Next 8 bits - 00 00 XX 00 will be used for Media packets TOS.
Next 16 bits - will be 0.
XX = Hex values: 0..FF
For mixed packets, TOS of Media Packets will be used.
Signaling packets are for example: Keep alive packets and ABCD signaling bits.
Media packets are for example: voice, fax, HDLC, payload packets."
::= { ip2IfEntry 10 }
ip2IfTDMBytesInFrame OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of TDM bytes to be placed in a single IP
frame payload.
For ip2IfTDMoIpMode = cesOverPsn this parameter indicates
the number of IP frames, calculated as: 1440/<Number of Timeslots>."
::= { ip2IfEntry 11 }
ip2IfVlanSupport OBJECT-TYPE
SYNTAX INTEGER {
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN support (Tagging).
no - No support to VLAN.
yes - 4 VLAN bytes will be added to the frame."
::= { ip2IfEntry 12}
ip2IfVlanIdentifier OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN ID."
::= { ip2IfEntry 13 }
ip2IfVlanFramePriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN Frame priority."
::= { ip2IfEntry 14 }
ip2IfExitPort OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
ext1 (2), -- Vmux 2100 slot 1 port 1 or Gmux2000 GbE Slot 6, Port 1
ext2 (3), -- Vmux 2100 slot 1 port 2 or Gmux2000 GbE Slot 6, Port 2
auto (4),
card2Ext1 (5), -- Vmux 2100 slot 2 port 1 or Gmux2000 GbE Slot 8, Port 1
card2Ext2 (6), -- Vmux 2100 slot 2 port 2 or Gmux2000 GbE Slot 6, Port 2
ext5 (7), -- Vmux-110/210/2100 ETH-NET
ext7 (8), -- Vmux-110/210 Serial Link
ext6 (9), -- Vmux-110/210 E1/T1 Link, Vmux-2100 E1/T1 Link A
prt17 (10), -- GMUX VMX/Vmux 2100 slot 1 port 3
prt18 (11), -- GMUX VMX/Vmux 2100 slot 1 port 4
prt19 (12), -- GMUX VMX/Vmux 2100 slot 2 port 3
prt20 (13), -- GMUX VMX/Vmux 2100 slot 2 port 4
prtE1T1B (14), -- Vmux 2100 E1/T1 Link B
prtEthUser (15), -- Vmux 2100/110/210 ETH-User
card3Ext1 (16), -- Vmux-2100 Slot 3 port 1
card3Ext2 (17), -- Vmux-2100 Slot 3 port 2
card3Ext3 (18), -- Vmux-2100 Slot 3 port 3
card3Ext4 (19), -- Vmux-2100 Slot 3 port 4
card4Ext1 (20), -- Vmux-2100 Slot 4 port 1
card4Ext2 (21), -- Vmux-2100 Slot 4 port 2
card4Ext3 (22), -- Vmux-2100 Slot 4 port 3
card4Ext4 (23), -- Vmux-2100 Slot 4 port 4
card1Ext3 (24), -- Gmux2000 GbE/8 Slot 6, Port 3
card1Ext4 (25), -- Gmux2000 GbE/8 Slot 6, Port 4
card1Ext5 (26), -- Gmux2000 GbE/8 Slot 6, Port 5
card1Ext6 (27), -- Gmux2000 GbE/8 Slot 6, Port 6
card1Ext7 (28), -- Gmux2000 GbE/8 Slot 6, Port 7
card1Ext8 (29), -- Gmux2000 GbE/8 Slot 6, Port 8
card2Ext3 (30), -- Gmux2000 GbE/8 Slot 8, Port 3
card2Ext4 (31), -- Gmux2000 GbE/8 Slot 8, Port 4
card2Ext5 (32), -- Gmux2000 GbE/8 Slot 8, Port 5
card2Ext6 (33), -- Gmux2000 GbE/8 Slot 8, Port 6
card2Ext7 (34), -- Gmux2000 GbE/8 Slot 8, Port 7
card2Ext8 (35) -- Gmux2000 GbE/8 Slot 8, Port 8
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object determines to which external port the traffic
will be sent.
auto - the device will decide automatically the exit port.
If there is an option for Tx via more than one ETH card then use ext1 (1) and ext2(2)
for ETH card #1 (ex. LAN1 or Ggabit-ETH1) and use card2Ext1(5) and card2Ext2(6) for
card #2 (ex. LAN1 or Ggabit-ETH1).
In Vmux-110/210 ext5 is used for ETH-NET, ext 6 is used for E1/T1 link and ext7 is
used for Serial Link.
In Vmux-2100 Main Board: ext 5 is used for ETH-NET, ext 6 is used for E1/T1 link A,
prtE1T1B is used for E1/T1 link B and prtEthUser is used for ETH-User.
prt17(10) - prt20(13) values were added in order to support Gmux2000 VMX Card."
::= { ip2IfEntry 15 }
ip2IfVoiceOos OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Voice Out-Of-Service code. Valid range: (0 - FF HEX).
For agents that do not support this feature, the value will
always be 0."
::= { ip2IfEntry 16 }
ip2IfDataOos OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Data Out-Of-Service code. Valid range: (0 - FF HEX).
For agents that do not support this feature, the value will
always be 0."
::= { ip2IfEntry 17 }
ip2IfBundleUsage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Bundle Resource usage in Kbps."
::= { ip2IfEntry 18 }
ip2IfOAM OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter determine the OAM configuration.
The LSB (Bit 0 the most right one) is used for OAM connectivity.
Values: 0 = disable, 1= enable."
::= { ip2IfEntry 19 }
ip2IfTDMoIpMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
static (2),
dynamicLES (3),
dynamicCAS (4),
cesOverIp (5),
voiceOverMpls (6),
hdlc (7),
voIpComprHeader (8),
voMplsComprHeader (9),
satop (10),
cesOverPsn (11),
hdlcOverPsn (12)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The TDMoIP Mode configuration. Static- means TS can Tx any time.
dynamicLES - means TS can Tx only when line is enabled according to LES protocol.
dynamicCAS - means TS can Tx only when line is enabled according to CAS protocol.
cesOverIp - use for information that this bundle is used for CES Over IP.
voiceOverMpls - Voice over Multi Protocol Label Switching.
hdlc - High Level Data Link.
voIpComprHeader - indicates proprietary compressed IP header packets.
voMplsComprHeader - indicates proprietary compressed MPLS header packets."
::= { ip2IfEntry 20 }
ip2IfTimeElapsed OBJECT-TYPE
SYNTAX Integer32 (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since
the beginning of the current error-measurement period.
If, for some reason, such as an adjustment in the
system's time-of-day clock, the current interval exceeds
the maximum value, the agent will return the maximum value."
::= {ip2IfEntry 21 }
ip2IfValidIntervals OBJECT-TYPE
SYNTAX Integer32 (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of previous intervals for which data was collected.
The value will be 96 unless the interface was brought online within
the last 24 hours, in which case the value will be
the number of complete 15 minute intervals since the
interface has been online. "
::= {ip2IfEntry 22 }
ip2IfFarEndType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
e1 (2),
t1Esf (3),
t1D4 (4),
fxs (5),
serialLink (6),
t1Unframed (7)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object defines the type of the Far-End device.
This data is important for signaling and DS0 format.
For Vmux: e1 (2) value is used for a PBX in the Far End.
fxs (5) is used for Phone.
Other values are not used. "
::= { ip2IfEntry 23 }
ip2IfRdnState OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
primary (3),
secondary (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines the role this bundle plays in the redundancy scheme:
none(2) - means this bundle is not part of redundancy pair.
primary/ secondary - means this bundle is not part of redundancy pair,
and that is the primary bundle or the secondary bunle. "
::= { ip2IfEntry 24 }
ip2IfSourceAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Source IP Address of the bundle."
::= {ip2IfEntry 25 }
ip2IfBandWidth OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Defines the Bandwidth of the bundle.
For TDM bundles - it is the Number of Time Slots in The Bundle.
- For T1 the value will be: 1..24
- For E1 the value will be: 1..31
- For T3 the value will be: 1..84
- For E3 the value will be: 1..63
This parameter is required for devices like Emux where the bandwidth of
the bundles is unknown. The bundles that are received should be transmitted
without any change in the bandwidth. It is the user's responsibility to
enter the correct bandwidth.
For Ethernet bundles - it is the bandwidth, measured in Kbps."
::= {ip2IfEntry 26 }
ip2IfMeasuredSilence OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows the percentage of Silence that was measured by the device
for the current bundle in the transmitted payload.
Relevant values: 0..100, 255.
Default value is 50.
0 means that there is no silence on the line.
100 means that there is only silence. In this case, there might be no traffic.
255 - value for not applicable or unknown."
::= { ip2IfEntry 27 }
ip2IfPayloadType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
data (2),
voice (3),
voiceAndCas (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object defines the TDMoIP payload type."
::= { ip2IfEntry 28 }
ip2IfProtocolVersion OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
v1 (2),
v2 (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object defines the TDMoIP protocol Version."
::= { ip2IfEntry 29 }
ip2IfTdmBackUpNextHop OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Defines the TDM bundle default router in case there was a switch from the Primary Link
(for example an ETH port) to a TDM backup Link like E1, T1 or Serial Link.
This parameter is relevant only when a Backup Link is configured.
When a Backup Link is not configured the value will be: 0.0.0.0"
::= { ip2IfEntry 30 }
ip2IfOosTxEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object defines whether OOS will be Transmitted.
Note that for IPmux1000 the Lbit is always sent,
but the OOS will be sent according to user selection in this parameter."
::= { ip2IfEntry 31 }
ip2IfConnCheckPktFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Time in sec. between 2 Bundle Connectivity Check packets.
Valid values: 0..60. 0 = Not Applicable."
::= { ip2IfEntry 32 }
ip2IfConnPktTimeOutCycles OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"No. of cycles the agent will send Bundle Connectivity packets without receiving
a response from the remote device before declaring that the bundle connection
to the remote side is down - Time Out.
Valid values: 0..5. 0 = Not Applicable."
::= { ip2IfEntry 33 }
ip2IfMfRelay OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Multi Frequency Signaling Detection."
::= { ip2IfEntry 34 }
ip2IfTxGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Transmit gain in dBm."
::= { ip2IfEntry 35 }
ip2IfSuperTandem OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Super Tandem feature provides end to end compression over multiple hops,
solving the double compression problem detected in Voice compressing systems.
The Super Tandem allows transmission of compressed voice between a few
Vmux 2100 hubs, and eliminates the need to decompress an recompress it over
each voice card and PBX, thus improving voice quality and reducing delay."
::= { ip2IfEntry 36 }
ip2IfSrcPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The source Bundle at the local device,
this parameter used for cases where there is no match
between ip2IfChannelIndex and the Source Bundle ID."
::= { ip2IfEntry 37 }
ip2IfModemCalls OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3),
relay (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This MIB object shows whether Modem Calls are enabled via the bundle.
relay option (3) means that the bundle will send to the network only
modulated data."
::= { ip2IfEntry 38 }
ip2IfMinPulseWidth OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the minimum width in milliseconds of the MF (Multi Frequency)
tone transmitted by the switch.
Valid values: 45-300 msec.
notApplicable=0."
::= { ip2IfEntry 39 }
ip2IfMinPowerLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the minimum power level in dBm of the MF (Multi Frequency)
tone transmitted by the switch.
Valid values: -1...-35 dBm."
::= { ip2IfEntry 40 }
ip2IfEchoCanceler OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Echo canceler activation."
::= { ip2IfEntry 41 }
ip2IfCodingLaw OBJECT-TYPE
SYNTAX INTEGER
{
aLAW (1),
uLAW (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute indicates the Method/Law for decoding/encoding the voice
information.
aLaw(1) is the standard Law for E1 links.
uLaw(2) is the standard Law for T1 links."
::= { ip2IfEntry 42 }
ip2IfCustomToneDetect OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Custom Tone Detection (COT) is a Control operation of a 2Khz tone detector.
This tone is sent between PBX devices in order to check that the line status
is OK. When the COT is enabled the device will not compress/decompress the tone.
In this case, if the tone is initiated by the local PBX, the Device runs
a 2Khz detector tone and once detected by the Remote Device, if the COT is enabled
in the Remote Device, the Remote Device will generate a 2khz tone to the remote PBX."
::= { ip2IfEntry 43 }
ip2IfCallerIdDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Time in msec between CLID (Caller ID) signal detection on the line and CLID
signal transmission. The CLID must be sent between ringing signals and the value
of the delay is used for synchronizing the CLID transmission with the ringing
signals transmission.
Valid values: 0 - 3000 msec."
::= { ip2IfEntry 44 }
ip2IfConnectivityMode OBJECT-TYPE
SYNTAX INTEGER
{
ping (2),
oam (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This MIB object shows whether to send Pings or OAM frames over the bundle."
::= { ip2IfEntry 45 }
ip2IfClockSourceEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This MIB object defines whether this bundle can be a clock source."
::= { ip2IfEntry 46 }
ip2IfNetworkType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
ip (2),
mplsEth (3),
mac (4),
ipComprHeader (5),
mplsComprHeader (6),
udp (7)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This MIB object defines the network over which the
Bundle PSN (Packet Switching Network)is transported.
In Gmux2000:
ipComprHeader indicates proprietary compressed IP header packets.
mplsComprHeader indicates proprietary compressed MPLS header packets."
::= { ip2IfEntry 47}
ip2IfMplsRxLabelEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This MIB object defines whether there is user defined
inner (Rx.) label for this Bundle."
::= { ip2IfEntry 48}
ip2IfMplsRxLabel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This MIB object defines the MPLS Rx. Label for this Bundle."
::= { ip2IfEntry 49}
ip2IfMplsTxLabelEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This MIB object defines whether there is user defined
outer (Tx.) label for this Bundle."
::= { ip2IfEntry 50}
ip2IfMplsTxLabel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This MIB object defines the MPLS Tx. Label for this Bundle."
::= { ip2IfEntry 51}
ip2IfMplsTxExpBits OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The MPLS Network priority (EXP bits) used for this bundle."
::= { ip2IfEntry 52}
ip2IfMfcSpoofing OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This MIB object defines whether the MFC (Multi Frequency Compelled) protocol
spoofing will exist in the bundle. When the MFC Spoofing is used, the Local
and Remote PBXs will send MFC Signaling to each other. The Vmuxes between
the PBXs will send proprietary signaling to each other. They will however
create and send MFC tones to their local PBX. The PBXs will not know that
the actual signaling was not sent from a PBX but from a Vmux."
::= { ip2IfEntry 53}
ip2IfToneAckInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Time Interval in milli seconds from the time a Vmux sends tone/s to a local PBX until
it receives an acknowledgement from this PBX.
Valid values: 60...400 in steps of 20."
::= { ip2IfEntry 54}
ip2IfNextHopType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
ipAddress (2),
macAddress (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This MIB object defines the Bundle next Hop Address Type."
::= { ip2IfEntry 55}
ip2IfNoiseLevelForVAD OBJECT-TYPE
SYNTAX INTEGER
{
low (2),
high (3),
off (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object defines the Level of Noise on the line,
the Voice Activation Detector (VAD) will have to handle."
::= { ip2IfEntry 56}
ip2IfClockPreferences OBJECT-TYPE
SYNTAX INTEGER
{
accurateness (2),
constantDelay (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Clock preferences:
accurateness (2) = Accurate clock is more important than Constant Delay.
constantDelay (3)= Constant Delay is more important than Accurate clock ."
::= { ip2IfEntry 57}
ip2IfConnectionMode OBJECT-TYPE
SYNTAX INTEGER
{
tdmOIpCe (2),
tdmOIpCv (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Connection Mode:
tdmOIpCe (2) = TDMOiP (CE) = Circuit Emulation.
tdmOIpCv (3)= TDMOiP (CV) = Compressed Voice."
::= {ip2IfEntry 58}
ip2IfRingBack OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enables or disable Ring Back."
::= {ip2IfEntry 59}
ip2IfReversePolarity OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enables or disable Reverse polarity synthesis."
::= {ip2IfEntry 60}
ip2IfPulseMeter OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enables or disable Pulse metering synthesis."
::= {ip2IfEntry 61}
ip2IfPulseMeterFreq OBJECT-TYPE
SYNTAX INTEGER
{
rate12Khz (2),
rate16Khz (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Frequency of synthesized pulse metering for this bundle."
::= {ip2IfEntry 62}
ip2IfPulseMeterPeriod OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Duration of synthesized pulse metering. current values are: 100-250."
::= {ip2IfEntry 63}
ip2IfOnHookDetect OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enables or disable immediate reaction to On-Hook bits from network in Ringing."
::= {ip2IfEntry 64}
ip2IfComfortNoiseGen OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable or disable Comfort Noise Generation (CNG).
When this parameter is enabled and no voice payload exists on the line for some
time period during the call (moments of silence), the device will generate a soft
background noise which assures the user that the connection is still alive (CNG).
When this parameter is disabled and no voice payload exists on the line,
absolute silence will be heard (Comfort Noise will not be generated)."
::= {ip2IfEntry 65}
ip2IfExitChannel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The channelized bundle that the voice bundle exits through.
In Gmux2000 it is the ifIndex of the Channelized Bundle (sub-channel)
that the Voice Bundle exits through. The ifIndex contains
the Slot+Prt+Channelized Bundle No."
::= {ip2IfEntry 66}
ip2IfMaxVBDModemCalls OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Maximum VBD modem calls for this bundle."
::= {ip2IfEntry 67}
ip2IfMaxRelayModemCalls OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Maximum Relay modem calls for this bundle."
::= {ip2IfEntry 68}
ip2IfCustomToneFrequency OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
f1780Hz (2),
f2000Hz (3),
f1780Plus2000Hz (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the frequency of the Custom Tone that is sent between PBXs in order
to check that the line status is OK. When the Custom Tone Detection is enabled
the device will not compress/decompress this tone. The custom tone that is received
from the local PBX will be sent to the remote PBX with the same frequency it was received.
When the Custom Tone Frequency is f1780Plus2000Hz (4), the device will not
compress/decompress any tone with frequencies of 1780Hz or 2000 Hz."
::= { ip2IfEntry 69 }
ip2IfVadMethod OBJECT-TYPE
SYNTAX INTEGER
{
proprietary (2),
internalITUT (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Voice Activity Detection (VAD) method.
proprietary (2) - non standard VAD based only on power measurement.
It is very sensitive to background noise.
internalITUT (3) - standard ITU-T VAD. It is a robust method."
::= {ip2IfEntry 70}
ip2IfRxGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Receive gain in dBm."
::= { ip2IfEntry 71 }
ip2IfCallerIDType OBJECT-TYPE
SYNTAX INTEGER
{
bellcoreType1 (2),
v23 (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Caller ID Type used by the DSP for this bundle.
Bellcore type is used by the American method.
V.23 type is used by the European method."
::= {ip2IfEntry 72}
ip2IfPeerAddrType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
ipAddress (2),
macAddress (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This MIB object defines the peer Address Type."
::= { ip2IfEntry 73}
ip2IfVbdRate OBJECT-TYPE
SYNTAX INTEGER
{
r64KbpsIn5msecIntervalsG711(2),
r64KbpsIn10msecIntervalsG711(3),
r32KbpsG726(4),
r24KbpsG726(5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Voice Band Data (VBD) rate for this bundle."
::= {ip2IfEntry 74}
ip2IfDtmfDetection OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/Disable DTMF (Dual Tone Multi Frequency) detectors for this bundle."
::= { ip2IfEntry 75 }
ip2IfNlpCutoffLevel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Non Linear Processor (NLP) Cutoff Level for this bundle.
This parameter is used by the echo canceller.
It is the maximum absolute linear PCM amplitude of the near-end signal that will
cause the NLP module to be active and to mute low level residual echo & noisy
surroundings."
::= { ip2IfEntry 76 }
ip2IfDtdErlRatioCutoffQ3 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The DTD ERL cutoff level is used in order to determine whether the near-end is talking
or not. This parameter is used by the echo canceller when echo exists and there is
voice with low volume on the line.
DTD means Double Talk Detection.
ERL means Echo Return Loss. It is the power difference [dB] between the far-end signal
to the echo returned.
The cutoff level is calculated for the value entering Q.3.
This value will be divided by 2^3=8 in order to get the linear ratio."
::= { ip2IfEntry 77 }
ip2IfCASRedundancy OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/Disable CAS signaling redundancy.
This parameter is useful when there are problems with the network and applicable
only for CAS signaling: E1-MF (G.732S) or E1-CRC-MF (G.732SCRC ).
enable (3) - means that each packet containing CAS signaling will be triplicated
into 3 packets.
disable (2)- No redundancy will exist. Only 1 packet containing CAS will be
transmitted."
::= { ip2IfEntry 78 }
ip2IfBundleSensitivity OBJECT-TYPE
SYNTAX INTEGER
{
delaySensitive (2),
dataSensitive (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Denotes if the bundle is sensitive to delay in the network,
or is sensitive to data errors in the network.
Voice bundles are sensitive to delay;
Non-voice bundles are sensitive to data errors."
::= { ip2IfEntry 79 }
ip2IfOAMBundleIdent OBJECT-TYPE
SYNTAX INTEGER
{
bundleNumber (2),
vccvCtrlWord (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Denotes if an OAM bundle is identified according to the Bundle Number (0x3fff),
or according to the value of the first nibble in the VCCV control word sent in the frame.
controlWord - applicable only when ip2IfProtocolVersion = v2(2).
When ip2IfProtocolVersion = v1(1), only bundleNumber is applicable."
::= { ip2IfEntry 80 }
ip2IfMaxTxQueue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Max Tx Queue buffer size, measured in msec (milliseconds).
Low buffer size may cause the buffer to overflow and discard packets
in case of burst of packets on the network.
High buffer size allows to store this burst and not lose packets."
::= { ip2IfEntry 81 }
ip2IfMaxGprsTxQueue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Max GPRS Tx Queue buffer size, measured in msec (milliseconds).
Low buffer size may cause the buffer to overflow and discard packets
in case of burst of packets on the network.
High buffer size allows to store this burst and not lose packets."
::= { ip2IfEntry 82 }
ip2IfV23HD OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter shows whether V.23 Half Duplex Modem Protocol is enabled
on the bundle."
::= { ip2IfEntry 83 }
ip2IfModemProtocolMode OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This octet string contains the mode of each Modem Protocol used on the bundle.
For each protocol one octet will be used.
Octet #1 will be used for V.22 Protocol.
Octet #2, #3, #4... are reserved for future protocols.
Octet #1 values:
0 - Not Applicable
1 - VBD: Voice Band Data.
2 - Relay: Pulse Code Modulated (PCM) data is sent via the bundle.
For V.22: This MIB object is relevant only when ip2IfModemCalls = relay (4)."
::= { ip2IfEntry 84 }
ip2IfCdisCngDetectionTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"When working with CDIS (Call DIScrimination method) or CNG (Comfort Noise Generation):
The time in msec that the device will detect 1100Hz & 2100Hz signals
on the line before switching to modem or fax.
For Vmux: the values will be in steps of 10 msec."
::= { ip2IfEntry 85 }
ip2IfSuperTandemBitMask OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This MIB object enables controlling the Time Slot/Channel rate.
Valid values: 1 - FF HEX
Each BIT represents 1/8 of the TS.
Example:
7E (0111 1110) means that 6/8 of the TS (the center ones) are masked and data will
be Tx/Rx only through them.
This MIB object is relevant only when Super Tandem is enabled."
::= { ip2IfEntry 86 }
ip2IfVbdSwitchbackTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Time in msec required for the DSP to switch back from VBD (Voice Band Data) to Voice.
For Vmux: the values will be in steps of 30 msec.
"
::= { ip2IfEntry 87 }
ip2IfCallerIdTxGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The gain value in dBm units used for transmitting the Caller ID signal on the bundle.
"
::= { ip2IfEntry 88 }
ip2IfCallerIdRxGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The gain value in dBm units of the Caller ID signal received on the bundle."
::= { ip2IfEntry 89 }
ip2IfUdpMuxMethod OBJECT-TYPE
SYNTAX INTEGER
{
srcPort (2),
destPort (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter determines according to which field the multiplexing is made:
srcPort (2) - multiplexing according to the UDP Source Port (Dest=0x085e).
This should be the default value, for backwards compatibility.
destPort (3) - multiplexing according to the UDP Destination Port
(standard multiplexing).
The UDP Source and Destination ports' range is determined according to
ip2IfUdpMuxMethod value:
For srcPort (2) the range is 1-7000
For destPort (3) the range is 49152-65535."
::= { ip2IfEntry 90 }
ip2IfCallerIdDetection OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/Disable Caller ID Detection for this bundle."
::= { ip2IfEntry 91 }
ip2IfWap OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/Disable WAP (Wireless Application Protocol) for this bundle.
WAP allows users to access the internet from wireless devices."
::= { ip2IfEntry 92 }
ip2IfSignalingOos OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
forcedIdle (3),
forcedBusy (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Out of Service code sent on signaling TimeSlot."
::= {ip2IfEntry 93}
ip2IfTDMFrameBytes OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of TDM bytes to be placed in a single IP
frame payload."
::= { ip2If 2 }
ip2IfTosValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TOS value to write in the IP frame."
::= { ip2If 3 }
ip2IfVlanTagging OBJECT-TYPE
SYNTAX INTEGER {
no (1),
yes (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN support.
no - No support to VLAN.
yes - 4 VLAN bytes will be added to the frame."
::= { ip2If 4 }
ip2IfVlanID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN ID."
::= { ip2If 5 }
ip2IfVlanPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frame priority."
::= { ip2If 6 }
-- ip2If Statistics table
ip2IfStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ip2IfStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Channels (Bundles) Statistics Table."
::= { ip2If 7 }
ip2IfStatEntry OBJECT-TYPE
SYNTAX Ip2IfStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IP Statistics per bundle"
INDEX { ip2IfStatChIndex }
::= { ip2IfStatTable 1 }
Ip2IfStatEntry ::=
SEQUENCE {
ip2IfStatChIndex Integer32,
ip2IfStatSeqErrors Integer32,
ip2IfStatBufUnderflows Integer32,
ip2IfStatBufOverflows Integer32,
ip2IfStatTxOnTimeInterval Counter32,
ip2IfStatTxOnMaxSize Counter32,
ip2IfStatRxSignaling Counter32,
ip2IfStatRxVoice Counter32,
ip2IfStatRxHdlc Counter32,
ip2IfStatTxSignaling Counter32,
ip2IfStatTxVoice Counter32,
ip2IfStatTxHdlc Counter32,
ip2IfStatRdnFlip Counter32,
ip2IfFarEndTdmStatus Integer32,
ip2IfStatPsnTxFrames Counter32,
ip2IfStatPsnRxFrames Counter32,
ip2IfStatMinJittBufLevel Unsigned32,
ip2IfStatMaxJittBufLevel Unsigned32,
ip2IfStatRecommendedJittBufSize Unsigned32,
ip2IfStatPsnSeqErrors Counter32,
ip2IfStatPsnReorderFrames Counter32,
ip2IfStatMinRoundTripDelay Unsigned32,
ip2IfStatMaxRoundTripDelay Unsigned32,
ip2IfStatAvrRoundTripDelay Unsigned32,
ip2IfStatFrameTrackDupDrop Counter32,
ip2IfStatFrameTrackMissing Counter32,
ip2IfStatFrameTrackLongSerMiss Integer32,
ip2IfStatTxMeasuredSilence Integer32,
ip2IfStatRxMeasuredSilence Integer32,
ip2IfStatHdlcCrcErr Counter32,
ip2IfStatHdlcAlignErr Counter32,
ip2IfStatHdlcOversize Counter32,
ip2IfStatHdlcUndersize Counter32,
ip2IfStatHdlcAbort Counter32,
ip2IfStatRxCorrectFrames Counter32,
ip2IfStatHdlcErroredFrames Counter32
}
ip2IfStatChIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The channel index, which is actualy the bundle ID."
::= { ip2IfStatEntry 1 }
ip2IfStatSeqErrors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of events that the sequence number of an incoming Frame
causes a transition from the 'sync' state to
the 'out of sequence' state."
::= { ip2IfStatEntry 2 }
ip2IfStatBufUnderflows OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of events that the buffer underflows. This records the count of the
number of events the Receive (Eth to TDM) buffer underflows. In the
case of a continuous underflow caused by a loss of Frame
flow, a single buffer underflow should be counted."
::= { ip2IfStatEntry 3 }
ip2IfStatBufOverflows OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of events that the buffer overflows. This records the count of the
number of events the Receive (Eth to TDM) buffer overflows."
::= { ip2IfStatEntry 4 }
ip2IfStatTxOnTimeInterval OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames that were transmitted due to time interval elapse.
The user can choose to Tx the Frame when it reaches the Max size
or when the packetizing time interval elapses.
The packetizing time interval is the interval in msec that it takes
to build a Max. size frame."
::= { ip2IfStatEntry 5 }
ip2IfStatTxOnMaxSize OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames that were transmitted due to reaching max.
frame size. The user can choose to Tx the Frame when it reaches the
Max size or when the packetizing time interval elapses."
::= { ip2IfStatEntry 6 }
ip2IfStatRxSignaling OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of signaling frames that were received."
::= { ip2IfStatEntry 7 }
ip2IfStatRxVoice OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of voice frames that were received."
::= { ip2IfStatEntry 8 }
ip2IfStatRxHdlc OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of HDLC frames that were received."
::= { ip2IfStatEntry 9 }
ip2IfStatTxSignaling OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of signaling frames that were transmitted."
::= { ip2IfStatEntry 10 }
ip2IfStatTxVoice OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of voice frames that were transmitted."
::= { ip2IfStatEntry 11 }
ip2IfStatTxHdlc OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of HDLC frames that were transmitted."
::= { ip2IfStatEntry 12 }
ip2IfStatRdnFlip OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of redundancy flips occured.
This parameter counts only flips from this bundle to the other bundle
in the redundancy couple."
::= { ip2IfStatEntry 13 }
ip2IfFarEndTdmStatus OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the Status of the Far-End TDM Line.
It contains failure state information.
The variable is a bit map represented as a sum, therefore, it
can represent multiple failures simultaneously.
The farEndTdmNoDefect must be set if and only if no other flag is set.
The various bit positions are:
1 farEndTdmNoDefect
2 farEndTdmAIS Alarm Indication Signal
4 farEndTdmRDI Remote Defect Indication"
::= { ip2IfStatEntry 14 }
ip2IfStatPsnTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames that were transmitted to PSN."
::= { ip2IfStatEntry 15 }
ip2IfStatPsnRxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames that were recieved from PSN."
::= { ip2IfStatEntry 16 }
ip2IfStatMinJittBufLevel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Minimum jitter buffer level (in msec)."
::= { ip2IfStatEntry 17 }
ip2IfStatMaxJittBufLevel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Maximum jitter buffer level (in msec)."
::= { ip2IfStatEntry 18 }
ip2IfStatRecommendedJittBufSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Recommended jitter buffer Size (in msec).
0= not applicable."
::= { ip2IfStatEntry 19 }
ip2IfStatPsnSeqErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times that the sequence number of an incoming Frame
indicates Loss of Frame or Out of order occured in PSN."
::= { ip2IfStatEntry 20 }
ip2IfStatPsnReorderFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times that Frames had been reordered in PSN."
::= { ip2IfStatEntry 21 }
ip2IfStatMinRoundTripDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum Round Trip delay (in msec).
0= not applicable."
::= { ip2IfStatEntry 22}
ip2IfStatMaxRoundTripDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum Round Trip delay (in msec).
0= not applicable."
::= { ip2IfStatEntry 23 }
ip2IfStatAvrRoundTripDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The avarage Round Trip delay (in msec).
0= not applicable."
::= { ip2IfStatEntry 24 }
ip2IfStatFrameTrackDupDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets dropped due to being duplicated.
(duplicated packet means a packet that has the same sequential
number as a packet being received previously)."
::= { ip2IfStatEntry 25 }
ip2IfStatFrameTrackMissing OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets that are missing.
(Missing packet means an expected packet- according to the current sequential
number - that was not received)."
::= { ip2IfStatEntry 26 }
ip2IfStatFrameTrackLongSerMiss OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The longest series of consecutive missing sequential numbers.
Missing sequential numbers represent missing packets that was
expected to be received successively."
::= { ip2IfStatEntry 27 }
ip2IfStatTxMeasuredSilence OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows the percentage of Silence that was measured by the device
for the current bundle in the transmitted payload.
Relevant values: 0..100, 255.
Default value is 50.
0 means that there is no silence on the line.
100 means that there is only silence. In this case, there might be no traffic.
255 - value for not applicable or unknown."
::= { ip2IfStatEntry 28 }
ip2IfStatRxMeasuredSilence OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows the percentage of Silence that was measured by the device
for the current bundle in the received payload.
Relevant values: 0..100, 255.
Default value is 50.
0 means that there is no silence on the line.
100 means that there is only silence. In this case, there might be no traffic.
255 - value for not applicable or unknown."
::= { ip2IfStatEntry 29 }
ip2IfStatHdlcCrcErr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter indicates the number of received HDLC frames
with CRC errors."
::= { ip2IfStatEntry 30 }
ip2IfStatHdlcAlignErr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter indicates the number of received HDLC frames
with alignment errors."
::= { ip2IfStatEntry 31 }
ip2IfStatHdlcOversize OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter indicates the number of received HDLC frames
longer than 1470."
::= { ip2IfStatEntry 32 }
ip2IfStatHdlcUndersize OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter indicates the number of received HDLC frames
shorter than 4."
::= { ip2IfStatEntry 33 }
ip2IfStatHdlcAbort OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter indicates the number of received HDLC frames
with abort indication."
::= { ip2IfStatEntry 34 }
ip2IfStatRxCorrectFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of received correct frames."
::= { ip2IfStatEntry 35 }
ip2IfStatHdlcErroredFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of received errored HDLC frames."
::= { ip2IfStatEntry 36 }
ip2IfRateLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum rate permitted to transfer via the network portin Mbps."
::= { ip2If 8 }
-- ip2If Port table
ip2IfPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ip2IfPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Port Table."
::= { ip2If 9 }
ip2IfPortEntry OBJECT-TYPE
SYNTAX Ip2IfPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Application layer configuration per Port"
INDEX { ip2IfPortIndex }
::= { ip2IfPortTable 1 }
Ip2IfPortEntry ::=
SEQUENCE {
ip2IfPortIndex Integer32,
ip2IfPortUsage Integer32,
ip2IfPortMask INTEGER,
ip2IfPortTotalThroughput Integer32
}
ip2IfPortIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Port index, which is actualy the ifIndex."
::= { ip2IfPortEntry 1 }
ip2IfPortUsage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates the usage of the port (percents)."
::= { ip2IfPortEntry 2 }
ip2IfPortMask OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
dontMask (2),
mask (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether Agent will mask port's alarms and statistics or not."
::= { ip2IfPortEntry 3 }
ip2IfPortTotalThroughput OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates the total Throughput of the port in bps."
::= { ip2IfPortEntry 4 }
-- ip2If Current Statistics table
ip2IfCurrentStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ip2IfCurrentStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Channels (Bundles) Current Statistics Table."
::= { ip2If 10 }
ip2IfCurrentStatEntry OBJECT-TYPE
SYNTAX Ip2IfCurrentStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IP Current Statistics per bundle"
INDEX { ip2IfChannelIndex }
::= { ip2IfCurrentStatTable 1 }
Ip2IfCurrentStatEntry ::=
SEQUENCE {
ip2IfCurrentStatSeqErrors Counter32,
ip2IfCurrentStatBufUnderflows Counter32,
ip2IfCurrentStatBufOverflows Counter32,
ip2IfCurrentStatMaxDelayVar Integer32,
ip2IfCurrentStatMinJittBufLevel Unsigned32,
ip2IfCurrentStatMaxJittBufLevel Unsigned32,
ip2IfCurrentStatTxErrFrameSec Counter32
}
ip2IfCurrentStatSeqErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of seconds that the sequence number of an incoming Frame
causes a transition from the 'sync' state to
the 'out of sequence' state in the current interval."
::= { ip2IfCurrentStatEntry 1 }
ip2IfCurrentStatBufUnderflows OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of seconds that the buffer underflows in the current interval.
This records the count of the number of seconds the Receive
(Eth to TDM) buffer underflows in the current interval. In the
case of a continuous underflow caused by a loss of Frame
flow, a single buffer underflow should be counted."
::= { ip2IfCurrentStatEntry 2 }
ip2IfCurrentStatBufOverflows OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of seconds that the buffer overflows in the current interval.
This records the count of the number of seonds the Receive
(Eth to TDM) buffer overflows in the current interval."
::= { ip2IfCurrentStatEntry 3 }
ip2IfCurrentStatMaxDelayVar OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum deviation from the center of the buffer (in msec) for the current interval."
::= { ip2IfCurrentStatEntry 4 }
ip2IfCurrentStatMinJittBufLevel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Minimum jitter buffer level (in msec) for the current interval."
::= { ip2IfCurrentStatEntry 5 }
ip2IfCurrentStatMaxJittBufLevel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Maximum jitter buffer level (in msec) for the current interval."
::= { ip2IfCurrentStatEntry 6 }
ip2IfCurrentStatTxErrFrameSec OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds in which errored frames were transmitted during the current interval.
The error may be one of the following:
CRC error, Alignment error, Oversized frame, Undersized frame, Aborted frame."
::= { ip2IfCurrentStatEntry 7 }
-- ip2If Interval Statistics table
ip2IfIntervalStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ip2IfIntervalStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Channels (Bundles) Interval Statistics Table."
::= { ip2If 11 }
ip2IfIntervalStatEntry OBJECT-TYPE
SYNTAX Ip2IfIntervalStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IP Interval Statistics per bundle"
INDEX { ip2IfChannelIndex, ip2IfIntervalStatIndex }
::= { ip2IfIntervalStatTable 1 }
Ip2IfIntervalStatEntry ::=
SEQUENCE {
ip2IfIntervalStatIndex Integer32,
ip2IfIntervalStatSeqErrors Counter32,
ip2IfIntervalStatBufUnderflows Counter32,
ip2IfIntervalStatBufOverflows Counter32,
ip2IfIntervalStatMaxDelayVar Integer32,
ip2IfIntervalStatMinJittBufLevel Unsigned32,
ip2IfIntervalStatMaxJittBufLevel Unsigned32,
ip2IfIntervalStatTxErrFrameSec Counter32
}
ip2IfIntervalStatIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Interval index, which is actualy the Interval number."
::= { ip2IfIntervalStatEntry 1 }
ip2IfIntervalStatSeqErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of seconds that the sequence number of an incoming Frame
causes a transition from the 'sync' state to
the 'out of sequence' state in the selected interval."
::= { ip2IfIntervalStatEntry 2 }
ip2IfIntervalStatBufUnderflows OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of seconds that the buffer underflows in the selected interval.
This records the count of the number of seconds the Receive
(Eth to TDM) buffer underflows in the selected interval. In the
case of a continuous underflow caused by a loss of Frame
flow, a single buffer underflow should be counted."
::= { ip2IfIntervalStatEntry 3 }
ip2IfIntervalStatBufOverflows OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of seconds that the buffer overflows in the selected interval.
This records the count of the number of seconds the Receive
(Eth to TDM) buffer overflows in the selected interval."
::= { ip2IfIntervalStatEntry 4 }
ip2IfIntervalStatMaxDelayVar OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum size of the buffer (in 10's of usec) in the selected interval.
For some devices (e.g. MP-4100) units are usec."
::= { ip2IfIntervalStatEntry 5 }
ip2IfIntervalStatMinJittBufLevel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Minimum jitter buffer level (in msec) for the selected interval.
For some devices (e.g. MP-4100) units are usec."
::= { ip2IfIntervalStatEntry 6 }
ip2IfIntervalStatMaxJittBufLevel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Maximum jitter buffer level (in msec) for the selected interval.
For some devices (e.g. MP-4100) units are usec."
::= { ip2IfIntervalStatEntry 7 }
ip2IfIntervalStatTxErrFrameSec OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds in which errored frames were transmitted during the selected interval.
The error may be one of the following:
CRC error, Alignment error, Oversized frame, Undersized frame, Aborted frame."
::= { ip2IfIntervalStatEntry 8 }
ip2IfLogEvents OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
all (2),
oneMinStep (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether all Jitter Buffer and Sequence Number events
will enter to Log File,
or enter those events to Log file in one minute steps."
::= { ip2If 12}
ip2IfEthSwitchMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
unTagged (2),
tagged (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether Eth Switch is in VLAN Tagged mode."
::= { ip2If 13}
--Traps
--The numbers 1-4 are used by Imx.txt
--The numbers 5-6 are used by IpmuxAtmTraps.txt
alarmLOS NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Loss Of Signal."
::= { radSysWanEvents 7 }
alarmLOF NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Loss Of Frame."
::= { radSysWanEvents 8 }
channelOperStatusTrap NOTIFICATION-TYPE
OBJECTS { ip2IfOperStatus }
STATUS current
DESCRIPTION
"This trap is sent upon any change in one or more channels."
::= { radSysWanEvents 9 }
alarmAIS NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates AIS."
::= { radSysWanEvents 10 }
alarmRDI NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates RDI."
::= { radSysWanEvents 11 }
alarmFEBE NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates FEBE."
::= { radSysWanEvents 12 }
localConnStatusTrap NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap is sent upon a change in Local connectivity
of Bundle connection."
::= { radSysWanEvents 13 }
remoteConnStatusTrap NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap is sent upon a change in Remote connectivity
of Bundle connection."
::= { radSysWanEvents 14 }
bundleConnectionStatusTrap NOTIFICATION-TYPE
OBJECTS { ifAlias, ip2IfOperStatus }
STATUS current
DESCRIPTION
"This trap is sent upon any change in the connectivity status
of a Bundle (ip2IfOperStatus).
The ifAlias index is the ifIndex of the bundle that its status has been changed."
::= { radSysWanEvents 15 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\ipmuxAtm.txt
--
-- File: IpmuxAtm.txt
alarmStatusTrap NOTIFICATION-TYPE
OBJECTS {atmInterfaceAlarmStatus}
STATUS current
DESCRIPTION
"The trap is sent whenever there is a transition from a no alarm
state to a state with at least one active alarm."
::= { radSysWanEvents 5 }
systemTrap NOTIFICATION-TYPE
OBJECTS { atmNteEventType, agnLed, alarmSeverity }
STATUS current
DESCRIPTION
"This trap alerts of major problems in the device."
::= { radSysWanEvents 6 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\bdband.txt
--
--RAD-BROADBAND-IF-MIB DEFINITIONS ::= BEGIN
--Version: 1.0
--Date: 14-Feb-2000
--By: Smadar Tauber
--File: bdband.mib
--
--Last update: 06-Jun-2004 by Shlomo Shoham
broadbandIf OBJECT IDENTIFIER ::= {diverseIfWanGen 8}
bdbandConfig OBJECT IDENTIFIER ::= {broadbandIf 1}
prtPhyPerfHistory OBJECT IDENTIFIER ::= {broadbandIf 2}
-- Indication Signal Table
prtBdbandIndTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtBdbandIndEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Indication Signal table."
::= { bdbandConfig 1 }
prtBdbandIndEntry OBJECT-TYPE
SYNTAX PrtBdbandIndEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Indication Signal table."
INDEX {prtBdbandCnfgIdx, prtBdbandIdx, prtBdbandIndSig, prtBdbandIndEvent}
::= { prtBdbandIndTable 1 }
PrtBdbandIndEntry ::=
SEQUENCE {
prtBdbandCnfgIdx
Integer32,
prtBdbandIdx
Integer32,
prtBdbandIndSig
INTEGER,
prtBdbandIndEvent
INTEGER,
prtBdbandIndSigEnable
INTEGER,
prtBdbandRowStatus
RowStatus
}
prtBdbandCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Agent Cnfg the following
objects refer.
255=Temporary Cnfg (when relevant, Set is done only to this configuration).
For Agents that support only one configuration, this object will be
constant=1. "
::= { prtBdbandIndEntry 1 }
prtBdbandIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique port or interface number.
For numbering, see product's spec.
For some products, the numbering can equal ifIndex."
::= { prtBdbandIndEntry 2 }
prtBdbandIndSig OBJECT-TYPE
SYNTAX INTEGER
{
ais (1),
rdi (2),
aisAndRdi (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique Indication Signal.
ais(1) = AIS = Alarm Indication Signal.
rdi(2) = RDI = Remote Defect Indication."
::= { prtBdbandIndEntry 3 }
prtBdbandIndEvent OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
slm (2),
fail (3),
eed (4),
pathTrace (5),
lom (6),
lop (7),
slu (8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique Event that can cause the Indication Signal.
slm(2) = SLM = Signal Label Mismatch
eed(4) = EED = Excessive Error Defect
pathTrace(5) = the end-to-end source/destination of information is wrong.
lom(6) = LOM = Loss of Multiframe.
lop(7) = LOP = Loss of Pointer.
slu(8) = SLU = Signal Label Unequipped."
::= { prtBdbandIndEntry 4 }
prtBdbandIndSigEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object allows user to define if the event specified by prtBdbandIndEvent
will cause creation of the Indication Signal specified by prtBdbandIndSig or not.
disable - will not enable causing the signal
enable - will enable causing the signal. "
::= { prtBdbandIndEntry 5 }
prtBdbandRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= { prtBdbandIndEntry 6 }
-- Port Phy Config Table
prtPhyConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtPhyConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Phy Config table. Used now for Phy25.6 Mbps."
::= { bdbandConfig 2 }
prtPhyConfigEntry OBJECT-TYPE
SYNTAX PrtPhyConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Phy Config table. "
INDEX { ifIndex }
::= { prtPhyConfigTable 1 }
PrtPhyConfigEntry ::=
SEQUENCE {
prtPhyTimeElapsed
Integer32,
prtPhyValidIntervals
Integer32
}
prtPhyTimeElapsed OBJECT-TYPE
SYNTAX Integer32 (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since
the beginning of the current error-measurement period."
::= { prtPhyConfigEntry 1 }
prtPhyValidIntervals OBJECT-TYPE
SYNTAX Integer32 (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of previous intervals for which valid data was collected.
The value will be 96 unless the interface was brought online within
the last 24 hours, in which case the value will be the number of complete
15 minute since the interface has been online."
::= { prtPhyConfigEntry 2 }
--Phy Performance History Tables
-- The PHY Current table contains various statistics being
-- collected for the current 15 minute interval.
prtPhyCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtPhyCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The 25.6 Mbps Section/Line Current table."
::= { prtPhyPerfHistory 1 }
prtPhyCurrentEntry OBJECT-TYPE
SYNTAX PrtPhyCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the 25.6 Mbps Line Current table.
ifIndex of the line 25.6 Mbps layer of type
25.6 Mbps."
INDEX { ifIndex }
::= { prtPhyCurrentTable 1 }
PrtPhyCurrentEntry ::=
SEQUENCE {
prtPhyCurrentLOS
Gauge32,
prtPhyCurrentLSV
Gauge32,
prtPhyCurrentUAS
Gauge32,
prtPhyCurrentSES
Gauge32,
prtPhyCurrentES
Gauge32,
prtPhyCurrentStatus
OCTET STRING,
prtPhyCurrentLOF
Gauge32
}
prtPhyCurrentLOS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Loss Of Sync
seconds, encountered by a 25.6 Mbps interface in
the current 15 minute interval."
::= { prtPhyCurrentEntry 1 }
prtPhyCurrentLSV OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line symbol violation
seconds, encountered by a 25.6 Mbps
interface in the current 15 minute interval."
::= { prtPhyCurrentEntry 2 }
prtPhyCurrentUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of UAS
encountered by a 25.6 Mbps
interface in the current 15 minute interval."
::= { prtPhyCurrentEntry 3 }
prtPhyCurrentSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SES
encountered by a 25.6 Mbps
interface in the current 15 minute interval."
::= { prtPhyCurrentEntry 4 }
prtPhyCurrentES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Errored Seconds, encountered by a
25.6 Mbps interface in the current 15 minute interval."
::= { prtPhyCurrentEntry 5 }
prtPhyCurrentStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statuses of the current interval:
0 - O.K.
1 - The link has been switched by a redundancy mechanism.
2 - Module is in/out.
4 - Empty - card is out."
::= { prtPhyCurrentEntry 6 }
prtPhyCurrentLOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Loss of Frames, encountered by an
interface in the current 15 minute interval."
::= { prtPhyCurrentEntry 7 }
-- The PHY interface Interval
-- The PHY Interval Table contains various statistics
-- collected by the Interface over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
prtPhyIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtPhyIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Line Interval table."
::= { prtPhyPerfHistory 2 }
prtPhyIntervalEntry OBJECT-TYPE
SYNTAX PrtPhyIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the 25.6 Mbps Line Interval table.
ifIndex of the line 25.6 Mbps layer of type 25.6 Mbps."
INDEX { ifIndex, prtPhyIntervalNumber }
::= { prtPhyIntervalTable 1 }
PrtPhyIntervalEntry ::=
SEQUENCE {
prtPhyIntervalNumber
Integer32,
prtPhyIntervalLOS
Gauge32,
prtPhyIntervalLSV
Gauge32,
prtPhyIntervalUAS
Gauge32,
prtPhyIntervalSES
Gauge32,
prtPhyIntervalES
Gauge32,
prtPhyIntervalStatus
OCTET STRING,
prtPhyIntervalLOF
Gauge32
}
prtPhyIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { prtPhyIntervalEntry 1 }
prtPhyIntervalLOS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Loss Of Sync
seconds , encountered by a 25.6 Mbps interface in
one of the previous 96, individual 15 minute intervals."
::= { prtPhyIntervalEntry 2 }
prtPhyIntervalLSV OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of line symbol violation
seconds , encountered by a 25.6 Mbps interface in
one of the previous 96, individual 15 minute intervals."
::= { prtPhyIntervalEntry 3 }
prtPhyIntervalUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of UAS
encountered by a 25.6 Mbps interface in one of the previous 96,
individual 15 minute intervals."
::= { prtPhyIntervalEntry 4 }
prtPhyIntervalSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SES
encountered by a 25.6 Mbps interface in one of the previous 96,
individual 15 minute intervals."
::= { prtPhyIntervalEntry 5 }
prtPhyIntervalES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Errored Seconds, encountered by a
25.6 Mbps interface in one of the previous 96, individual 15
minute intervals."
::= { prtPhyIntervalEntry 6 }
prtPhyIntervalStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The statuses of the current interval:
0 - O.K.
1 - The link has been switched by a redundancy mechanism.
2 - Module is in/out.
4 - Empty - card is out."
::= { prtPhyIntervalEntry 7 }
prtPhyIntervalLOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Loss of Frames, encountered by an
interface in one of the previous 96, individual 15
minute intervals."
::= { prtPhyIntervalEntry 8 }
-- END
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\r2.txt
--
--Title: RAD's WAN R2 Interface MIB
--By: Smadar Tauber
--Date : 18.04.2000
--Last Update: 23-June-02
--By: Smadar Tauber
--File: v:\doc\rdv\mib\ver490\r2.txt
--wanGen OBJECT IDENTIFIER ::= {radWan 1}
--diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6} (see mpmx.txt)
r2If OBJECT IDENTIFIER ::= {diverseIfWanGen 9}
r2ProfileCnfg OBJECT IDENTIFIER ::= {r2If 1}
r2IfStatus OBJECT IDENTIFIER ::= {r2If 2}
--R2 Profile Configuration tables
--
--Only the profiles that are defined having agnSigProfType=r2Cas will
--exist in these tables.
--The parameters of the r2CnfgTable are defined per configuration, per Country (RW).
r2CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF R2CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { r2ProfileCnfg 1}
r2CnfgEntry OBJECT-TYPE
SYNTAX R2CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {r2CnfgIdx, r2CnfgProfileIdx}
::= { r2CnfgTable 1}
R2CnfgEntry ::=
SEQUENCE {
r2CnfgIdx Integer32,
r2CnfgProfileIdx Integer32,
r2Mode INTEGER,
r2Country Integer32,
r2Delay INTEGER,
r2MeteringInd INTEGER,
r2BreakMakeRatio INTEGER,
r2ReleaseGuardT2 Integer32,
r2Regret Integer32,
r2SeizeDetect Integer32,
r2SeizeAckDelay Integer32,
r2ClearBackDetect Integer32,
r2ClearFwdDetect Integer32,
r2FaultDetect Integer32,
r2FaultRemoveDetect Integer32,
r2MeterPulseDuration Integer32,
r2SeizeAckWait Integer32,
r2SeizeAckDetect Integer32,
r2AnswerDetect Integer32,
r2BlockRemoveDetect Integer32,
r2MeterPulseDetect Integer32,
r2ForcedDisconnect Integer32,
r2DisconnectAck Integer32,
r2ReleaseGuardT1 Integer32,
r2CnfgRowStatus RowStatus
}
r2CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg being accessed.
255 = TmpCnfg.
1 = Current Cnfg.
Write is allowed only to TmpCnfg."
::= {r2CnfgEntry 1}
r2CnfgProfileIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Profile Index.
Valid values: 1..5
Only instances of profiles that are defined having agnSigProfType=r2Cas will
exist in this table."
::= {r2CnfgEntry 2}
r2Mode OBJECT-TYPE
SYNTAX INTEGER
{
auto (2),
manual(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"R2 Mode.
auto - in this mode, default value of timers will be used by R2,
according to the selected r2Country.
manual - in this mode, user can change the value of R2 timers within the valid
limits, specific to each country."
::= {r2CnfgEntry 3}
r2Country OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"R2 Country. R2 Timers can have different range of values and
defaults for each country. When r2Mode=auto, the default value is
used by R2 according to this selected country.
1=ITU-T (standard values)
2=Korea
3=India
4=Brasil (continuous)
5=Brasil (pulsed)
6..10 - reserved for future countries."
::= {r2CnfgEntry 4}
r2Delay OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
terrestrial (2),
satellite (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables user to configure the link as satellite or terrestrial.
The seize acknowledge detect timing is much shorter (msec) for
terrestrial link than for satellite link (1-2 sec)."
::= {r2CnfgEntry 5}
r2MeteringInd OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
cBit (2),
bBit (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Which Bit will be used for Metering Indication."
::= {r2CnfgEntry 6}
r2BreakMakeRatio OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
break56Make44(2),
break64Make36(3),
break80Make20(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object describes the Break-Make Ratio of Pulse Duration, in [msec].
RW only when r2Mode=manual."
::= {r2CnfgEntry 7}
r2ReleaseGuardT2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Release Guard timing T2.
Release guard timing before going to idle, in [msec].
RW only when r2Mode=manual."
::= {r2CnfgEntry 8}
r2Regret OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Regret duration, in [sec].
RW only when r2Mode=manual."
::= {r2CnfgEntry 9}
r2SeizeDetect OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Seize Detect. Timer of the R2 incoming side.
Minimum duration to detect a valid seizure, in [msec].
RW only when r2Mode=manual."
::= {r2CnfgEntry 10}
r2SeizeAckDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Timer of the R2 incoming side.
Delay before sending a valid seize ack signal, in [msec].
Applicable only when r2Mode=manual. only when r2Mode=manual."
::= {r2CnfgEntry 11}
r2ClearBackDetect OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Timer of the R2 incoming side.
Minimum duration to recognize a valid clear-back, in [msec].
RW only when r2Mode=manual."
::= {r2CnfgEntry 12}
r2ClearFwdDetect OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Timer of the R2 incoming side.
Minimum duration to recognize a valid clear-forward, in [msec].
RW only when r2Mode=manual."
::= {r2CnfgEntry 13}
r2FaultDetect OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Timer of the R2 incoming side.
Minimum duration to recognize a block signal, in [msec].
RW only when r2Mode=manual."
::= {r2CnfgEntry 14}
r2FaultRemoveDetect OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Timer of the R2 incoming side.
Minimum duration to recognize a valid block removal signal, in [msec].
RW only when r2Mode=manual."
::= {r2CnfgEntry 15}
r2MeterPulseDuration OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Timer of the R2 incoming side.
Duration of metering pulse to be sent, in [msec].
RW only when r2Mode=manual."
::= {r2CnfgEntry 16}
r2SeizeAckWait OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Timer of the R2 outgoing side.
Minimum duration to receive seizure acknowledge signal, in [msec].
RW only when r2Mode=manual."
::= {r2CnfgEntry 17}
r2SeizeAckDetect OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Timer of the R2 outgoing side.
Minimum duration to recognize a valid seizure acknowledge signal, in [msec].
RW only when r2Mode=manual."
::= {r2CnfgEntry 18}
r2AnswerDetect OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Timer of the R2 outgoing side.
Minimum duration to recognize a valid answer signal, in [msec].
RW only when r2Mode=manual."
::= {r2CnfgEntry 19}
r2BlockRemoveDetect OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Timer of the R2 outgoing side.
Minimum duration to recognize a valid block removal signal, in [msec].
RW only when r2Mode=manual."
::= {r2CnfgEntry 20}
r2MeterPulseDetect OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Timer of the R2 outgoing side.
Minimum duration of incoming meter pulse, in [msec].
RW only when r2Mode=manual."
::= {r2CnfgEntry 21}
r2ForcedDisconnect OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Timer of the R2 outgoing side.
Minimum duration to recognize disconnect signal, in [msec].
RW only when r2Mode=manual."
::= {r2CnfgEntry 22}
r2DisconnectAck OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Timer of the R2 outgoing side.
Minimum duration to recognize disconnect acknowledge signal, in [msec].
RW only when r2Mode=manual."
::= {r2CnfgEntry 23}
r2ReleaseGuardT1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Timer of the R2 outgoing side.
Minimum duration to release guard, in [msec].
During this time, no new call can be initiated.
RW only when r2Mode=manual."
::= {r2CnfgEntry 24}
r2CnfgRowStatus OBJECT-TYPE
SYNTAX RowStatus
--active(1),
--destroy(6)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables the user to add/delete entries to/from the table."
::= {r2CnfgEntry 25}
--The configuration parameters of the r2TsTable are defined per configuration,
--per Profile, per TS (RW Table).
r2TsTable OBJECT-TYPE
SYNTAX SEQUENCE OF R2TsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { r2ProfileCnfg 2}
r2TsEntry OBJECT-TYPE
SYNTAX R2TsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {r2TsCnfgIdx, r2TsProfileIdx, r2TsIdx}
::= { r2TsTable 1}
R2TsEntry ::=
SEQUENCE {
r2TsCnfgIdx Integer32,
r2TsProfileIdx Integer32,
r2TsIdx Integer32,
r2TsCallEnable INTEGER,
r2TsMetering INTEGER,
r2TsRowStatus RowStatus,
r2TsReversePolarity INTEGER
}
r2TsCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg being accessed.
255 = TmpCnfg.
1 = Current Cnfg.
Write is allowed only to TmpCnfg."
::= {r2TsEntry 1}
r2TsProfileIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Profile Index.
Valid values: 1..5
Only instances of profiles that are defined having agnSigProfType=r2Cas will
exist in this table."
::= {r2TsEntry 2}
r2TsIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS Index.
Valid values: 1..31"
::= {r2TsEntry 3}
r2TsCallEnable OBJECT-TYPE
SYNTAX INTEGER
{
incoming (2),
outgoing (3),
both (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the Enabled Call direction for the specific TS."
::= {r2TsEntry 4}
r2TsMetering OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates if the specific TS should support Metering."
::= {r2TsEntry 5}
r2TsRowStatus OBJECT-TYPE
SYNTAX RowStatus
--active(1),
--destroy(6)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables the user to add/delete entries to/from the table."
::= {r2TsEntry 6}
r2TsReversePolarity OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates if the specific TS should support Reverse Polarity."
::= {r2TsEntry 7}
--R2 Status table (RO) - TS Level, per Link
--
--The table is applicable only for E1 Links having an R2 Profile.
r2StatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF R2StatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { r2IfStatus 1}
r2StatusEntry OBJECT-TYPE
SYNTAX R2StatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {r2StatusSlotIdx, r2StatusPortIdx, r2StatusTsIdx}
::= { r2StatusTable 1}
R2StatusEntry ::=
SEQUENCE {
r2StatusSlotIdx INTEGER,
r2StatusPortIdx Integer32,
r2StatusTsIdx Integer32,
r2StatusSigDirection INTEGER,
r2StatusTsState INTEGER,
r2StatusProtocolState INTEGER
}
r2StatusSlotIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot Index"
::= {r2StatusEntry 1}
r2StatusPortIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique port number of the ML having
R2 interface.
Valid values: exPrt1 (1)..exPrt4 (4)"
::= {r2StatusEntry 2}
r2StatusTsIdx OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time Slot index."
::= {r2StatusEntry 3}
r2StatusSigDirection OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
incoming (2),
outgoing (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"R2 Time Slot Signaling Direction."
::= {r2StatusEntry 4}
r2StatusTsState OBJECT-TYPE
SYNTAX INTEGER
{
notUsed (1),
normal (2),
remoteBlocked (3),
localBlocked (4),
localLoop (5),
remoteLoop (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"R2 TS State"
::= {r2StatusEntry 5}
r2StatusProtocolState OBJECT-TYPE
SYNTAX INTEGER
{
idle (1),
seized (2),
seizureAcknowledged (3),
answered (4),
clearForward (5),
clearBack (6),
blocked (7),
forcedDisc (8),
doubleSeizure (9),
fault (10),
discAcknowledged (11),
fault1 (12),
fault6 (13),
fault3 (14)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"R2 Protocol State."
::= {r2StatusEntry 6}
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\layer2.txt
--
--
-- file: v:\doc\rdv\mib\ver495\atm\layer2.txt
--
--RTR-MIB
--
--Last update: 25-Sep-2002
--By: Shay Harari
-- ************************************************
-- Link Layer (layer 2) MIB
-- ************************************************
atmLayer2 OBJECT IDENTIFIER ::= {radAtm 7}
atmLayer2XVclTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmLayer2XVclEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of VCL table, which is created
for each LAN VCC."
::= { atmLayer2 1 }
atmLayer2XVclEntry OBJECT-TYPE
SYNTAX AtmLayer2XVclEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Conceptual row in atmVclTable.
This table augments the RFC2515 VCL table."
AUGMENTS { atmVclEntry }
::= { atmLayer2XVclTable 1 }
AtmLayer2XVclEntry ::= SEQUENCE {
atmLayer2XVclConnMode INTEGER,
atmLayer2XVclGroupIdx Integer32
}
atmLayer2XVclConnMode OBJECT-TYPE
SYNTAX INTEGER {
main (1),
sub (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Each valid LAN VCC is either Main or Sub.
This parameter is configured only once on creation of a LAN VCC.
It can not be changed after creation. In order to change the Mode,
user should delete the connection and create a new one.
main - A LAN VCC, which holds its own bridge port.
Bridge forwarding and Bridge learning is performed only on Main
VCCs.
For working on a transparent bridge, that doesn't perform
layer 2 priority mapping, a Main VCC should be opened, which
is the default connection Mode.
When working with layer 2 priority, a group of LAN VCCs should
be configured, where each group will be associated with only
one Main VCC.
A specific Main can not be used by more than one group.
sub - A LAN VCC is not part of the bridging mechanism.
A Sub VCC automatically inherit some general definitions from
Main VCC of its group: ATM Slot/Port and LAN Slot/Port.
Max number of Sub VCCs allowed per group is:
[Number of Priorities - 1]."
::= { atmLayer2XVclEntry 1 }
atmLayer2XVclGroupIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The group identifier.
A VCC Group identifier = 0 if the VCC was not associated with a
group yet.
This value is updated according to the group identifier set by
atmLayer2GroupTable."
::= { atmLayer2XVclEntry 2 }
atmLayer2GroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmLayer2GroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains groups and their members.
A group is a bundle of VCCs, which acts as different queues.
Main and Sub VCCs should have the same ATM slot and port,
and the same LAN slot and port.
Each group contains: 1 to <number of priorities> VCCs."
::= { atmLayer2 2 }
atmLayer2GroupEntry OBJECT-TYPE
SYNTAX AtmLayer2GroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Conceptual row in atmLayer2GroupTable.
The indexes: ifIndex, atmVclVpi and atmVclVci indicate
the Network ATM End-Point.
Upon a group creation, one Main VCC must be added first.
After the group was created, Sub VCCs may be added to the group."
INDEX { atmLayer2GroupIdx, ifIndex, atmVclVpi, atmVclVci }
::= { atmLayer2GroupTable 1 }
AtmLayer2GroupEntry ::= SEQUENCE {
atmLayer2GroupIdx Integer32,
atmLayer2GroupRowStatus RowStatus,
atmLayer2GroupConnMode INTEGER,
atmLayer2GroupConnPriority OCTET STRING,
atmLayer2GroupName SnmpAdminString
}
atmLayer2GroupIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The group identifier.
0 is not a valid index."
::= { atmLayer2GroupEntry 1 }
atmLayer2GroupRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table, and indication of the
entry's status."
::= {atmLayer2GroupEntry 2 }
atmLayer2GroupConnMode OBJECT-TYPE
SYNTAX INTEGER {
main (1),
sub (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Each valid LAN VCC is either Main or Sub as configured in
atmLayer2XVclTable."
::= { atmLayer2GroupEntry 3 }
atmLayer2GroupConnPriority OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter is configured by atmLayer2PriorityRx from
atmLayer2PriorityTable.
Each bit in the Octet represents a specific priority as follows:
MSB 7 6 5 4 3 2 1 0 LSB -> Priorities
|____________________|
1 0 0 1 0 0 0 1 -> Value
In this example, a certain VCC has several priorities: 0, 4 and 7."
::= { atmLayer2GroupEntry 4 }
atmLayer2GroupName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Group name. Configured by the user.
The name is unique per system.
For atmLayer2GroupIdx=0, the name will be null."
::= { atmLayer2GroupEntry 5 }
atmLayer2PriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmLayer2PriorityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table maps all priorities inside a group.
Several priorities might be mapped to the same VCC.
Upon priority change, the agent will update the VCCs of the
changed priority in this table, and will update -
atmLayer2GroupConnPriority parameter of both former and new owners
of the changed priority.
Changing a VCC value is actually a change of three parameters
simultaneously: atmLayer2PriorityIfIndex, atmLayer2PriorityVclVpi
and atmLayer2PriorityVclVci. Otherwise, the set will be rejected,
since there might be that such VCC doesn't exist in the specific
group."
::= { atmLayer2 3 }
atmLayer2PriorityEntry OBJECT-TYPE
SYNTAX AtmLayer2PriorityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Conceptual row in atmLayer2PriorityTable.
Each entry is a Network ATM End-Point per priority.
Upon a group creation, all priorities are mapped to the Main VCC.
Number of entries per group is according to the number of
priorities enabled. (For example, for Max priorities = 8,
the agent will create 8 entries)."
INDEX { atmLayer2PriorityGroupIdx, atmLayer2PriorityRx }
::= { atmLayer2PriorityTable 1 }
AtmLayer2PriorityEntry ::= SEQUENCE {
atmLayer2PriorityGroupIdx Integer32,
atmLayer2PriorityRx Integer32,
atmLayer2PriorityIfIndex InterfaceIndex,
atmLayer2PriorityVclVpi Integer32,
atmLayer2PriorityVclVci Integer32
}
atmLayer2PriorityGroupIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The group identifier."
::= { atmLayer2PriorityEntry 1 }
atmLayer2PriorityRx OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The priority values.
The used values are 0-7, but since this value is part of the index
of the table, and in order to avoid '0' as an index, the index syntax
is 1..8, but the real value is atmLayer2PriorityRx-1:
0 - for Low priority.
7 - for High priority."
::= { atmLayer2PriorityEntry 2 }
atmLayer2PriorityIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ATM ifIndex of the network End-Point."
::= { atmLayer2PriorityEntry 3 }
atmLayer2PriorityVclVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Vpi of the network End-Point."
::= { atmLayer2PriorityEntry 4 }
atmLayer2PriorityVclVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Vci of the network End-Point."
::= { atmLayer2PriorityEntry 5 }
atmLayer2GroupIndexNext OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an appropriate value to
be used for atmLayer2GroupIdx when creating
entries in the atmLayer2GroupTable. The value
0 indicates that no unassigned entries are
available. To obtain the atmLayer2GroupIdx
value for a new entry, the manager gets
the current value of this object. The next index
will be of the first unassigned entry. It will be
provided by checking the assigned entries."
::= { atmLayer2 4 }
--VLAN
atmLayer2CfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmLayer2CfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Bridge configuration Table. This table supports multi-bridge
and bridge features within an ATM device."
::= { atmLayer2 5 }
atmLayer2CfgEntry OBJECT-TYPE
SYNTAX AtmLayer2CfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Conceptual row in atmLayer2CfgTable.
Each entry in this table contains the bridging attributes for
both Ethernet and ATM sides.
The interface index is the Ethernet port interface.
For Ace52: this object represents the Bridge ifIndex."
INDEX { ifIndex }
::= { atmLayer2CfgTable 1 }
AtmLayer2CfgEntry ::= SEQUENCE {
atmLayer2CfgBridgingMode INTEGER,
atmLayer2CfgVlanMode INTEGER,
atmLayer2CfgAtmAcceptableFrameType INTEGER,
atmLayer2CfgAtmIngressFiltering TruthValue,
atmLayer2CfgAtmTxFrameType INTEGER,
atmLayer2CfgEthAcceptableFrameType INTEGER,
atmLayer2CfgBridgeAction INTEGER,
atmLayer2CfgLearningMode INTEGER,
atmLayer2CfgAgingTime Integer32
}
atmLayer2CfgBridgingMode OBJECT-TYPE
SYNTAX INTEGER {
accessOnly(1),
accessAndSwitching (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bridging mode can be one of the following:
ATM <> Ethernet - Bridging is between the Ethernet
port and the ATM port (there is no bridging between VCs).
ATM <> Ethernet + ATM - Bridging is done both between
the Ethernet port and the ATM port and also between VCs."
::= { atmLayer2CfgEntry 1 }
atmLayer2CfgVlanMode OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN Mode. Upon Mode changing, all LAN VCCs will be deleted
by the agent from all tables that include LAN VCCs."
::= { atmLayer2CfgEntry 2 }
atmLayer2CfgAtmAcceptableFrameType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
admitAll (2),
admitOnlyVlanTagged (3),
admitOnlyUnTagged (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Frame Type that will be acceptable by the VCCs that
are associated with this Ethernet port.
Frames which don't match the selected type will be discarded.
admitAll - all frames will be accepted.
admitOnlyVlanTagged - only Tagged frames will be accepted.
admitOnlyUnTagged - only unTagged frames will be accepted."
::= { atmLayer2CfgEntry 3 }
atmLayer2CfgAtmIngressFiltering OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For the VCCs that are associated with this Ethernet port,
when this is true(1) the device will discard incoming
frames for VLANs which do not include this Port in its
Member set. When false(2), the port will accept all
incoming frames."
::= { atmLayer2CfgEntry 4 }
atmLayer2CfgAtmTxFrameType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
unTagged (2),
tagged (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Frame Type that will be transmitted by the VCCs that
are associated with this Ethernet port.
unTagged - The transmitted frames will be unTagged.
tagged - The transmitted frames will be Tagged."
::= { atmLayer2CfgEntry 5 }
atmLayer2CfgEthAcceptableFrameType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
admitAll (2),
admitOnlyVlanTagged (3),
admitOnlyUnTagged (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Frame Type that this Ethernet port will accept.
(for ACE-52: the Frame Type that this Bridge will accept)
This parameter is notApplicable for atmLayer2VlanMode=disable.
Frames which don't match the selected type will be discarded.
admitAll - all frames will be accepted.
admitOnlyVlanTagged - only Tagged frames will be accepted.
admitOnlyUnTagged - only unTagged frames will be accepted."
::= { atmLayer2CfgEntry 6 }
atmLayer2CfgBridgeAction OBJECT-TYPE
SYNTAX INTEGER {
deleteLanTable (7),
noOp (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables to perform the specified action on the
selected port."
::= { atmLayer2CfgEntry 7 }
atmLayer2CfgLearningMode OBJECT-TYPE
SYNTAX INTEGER {
svl (1),
ivl (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the mode of the learning process of a bridge.
svl - Shared VLAN process. If an individual MAC Address is learned
in one VLAN, this information is used in forwarding decisions
taken for that address for all other VLANs.
ivl - Independent VLAN process. If an individual MAC Address is learned
in one VLAN, this information is not used in forwarding decisions
taken for that address for all other VLANs."
::= { atmLayer2CfgEntry 8 }
atmLayer2CfgAgingTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The timeout period in seconds for aging out
dynamically learned forwarding information."
::= { atmLayer2CfgEntry 9 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\fratm.txt
--
--
-- file: v:\doc\rdv\mib\ver470\atm\frAtm.txt
--
--FR-ATM-IWF-X-MIB
--
--Last update: 28-Feb-2001
--By: Ilana Schvetz
--atmSuPortFr OBJECT IDENTIFIER ::= { atmSuPort 4 }
radAtmFr OBJECT IDENTIFIER ::= {radAtm 8}
frAtmIwfXConnectionTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrAtmIwfXConnectionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of frAtmIwfXConnectionTable from
RFC2955."
::= { radAtmFr 1 }
frAtmIwfXConnectionEntry OBJECT-TYPE
SYNTAX FrAtmIwfXConnectionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Conceptual row in frAtmIwfXConnectionTable.
This table augments the RFC2955."
AUGMENTS { frAtmIwfConnectionEntry }
::= { frAtmIwfXConnectionTable 1 }
FrAtmIwfXConnectionEntry ::= SEQUENCE {
frAtmIwfXConnMode INTEGER,
frAtmIwfXConnSscsDlci Integer32
}
frAtmIwfXConnMode OBJECT-TYPE
SYNTAX INTEGER { service(1), network(2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"FR IWF Mode.
service - Service InterWorking (FRF.8),
network - Network InterWorking (FRF.5)."
::= { frAtmIwfXConnectionEntry 1 }
frAtmIwfXConnSscsDlci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter is relevant for
frAtmIwfXConnMode=network (FRF.5) only.
This parameter allow configuration of the
FR SSCS DLCI that is transferred to the
remote FR unit."
::= { frAtmIwfXConnectionEntry 2 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\radaal5.txt
--
--
-- file :v:\doc\rdv\mib\ver495\atm\radaal5.txt
--
--Last update: 19-Nov-2002 by Ilana Schvetz
-- ATM-X-MIB DEFINITIONS ::= BEGIN
--
--atmGen OBJECT IDENTIFIER ::= {radAtm 2}
--atmPerfHistory OBJECT IDENTIFIER ::= {atmGen 1}
--atmIfPerformance OBJECT IDENTIFIER ::= {atmPerfHistory 1}
-- AAL5 Virtual Channel Connection Performance Statistics
-- Table
-- This table contains the AAL5 extension
-- performance statistics of a VCC at the
-- interface associated with an AAL5 entity in an ATM
-- host or ATM switch.
aal5VccXTable OBJECT-TYPE
SYNTAX SEQUENCE OF Aal5VccXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension to AAL5 VCC Table."
::= { atmIfPerformance 4 }
aal5VccXEntry OBJECT-TYPE
SYNTAX Aal5VccXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This list contains the additional AAL5 VCC
performance parameters and is indexed
by ifIndex values of AAL5 interfaces
and the associated VPI/VCI values."
AUGMENTS { aal5VccEntry }
::= { aal5VccXTable 1 }
Aal5VccXEntry ::= SEQUENCE {
aal5VccInFrames Counter32,
aal5VccOutFrames Counter32,
aal5VccUnknownProtocolFrames Counter32
}
aal5VccInFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received via this interface."
::= { aal5VccXEntry 1 }
aal5VccOutFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames transmitted out of the
interface."
::= { aal5VccXEntry 2 }
aal5VccUnknownProtocolFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames that were discarded due to unsupported
protocol encapsulation on this VCC."
::= { aal5VccXEntry 3 }
aal5VccCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF Aal5VccCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The AAL5 Current table."
::= { atmIfPerformance 5 }
aal5VccCurrentEntry OBJECT-TYPE
SYNTAX Aal5VccCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the AAL5 Current table."
INDEX { ifIndex, aal5VccVpi, aal5VccVci }
::= { aal5VccCurrentTable 1 }
Aal5VccCurrentEntry
::= SEQUENCE {
aal5VccCurrentInFrames
Gauge32,
aal5VccCurrentOutFrames
Gauge32,
aal5VccCurrentUnknownProtocolFrames
Gauge32,
aal5VccCurrentCrcErrors
Gauge32,
aal5VccCurrentLengthError
Gauge32,
aal5VccCurrentInputCongestionDropped
Gauge32,
aal5VccCurrentOutputCongestionDropped
Gauge32
}
aal5VccCurrentInFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames,
encountered by the AAL5 interface in the current 15 minute
interval."
::= { aal5VccCurrentEntry 1 }
aal5VccCurrentOutFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted frames,
encountered by the AAL5 interface in the current 15 minute
interval."
::= { aal5VccCurrentEntry 2 }
aal5VccCurrentUnknownProtocolFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of frames that were
discarded due to unsupported protocol encapsulation,
encountered by the AAL5 interface in the current 15 minute
interval."
::= { aal5VccCurrentEntry 3 }
aal5VccCurrentCrcErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of AAL5 CPCS PDUs
received with CRC-32 errors, encountered by the AAL5
interface in the current 15 minute interval."
::= { aal5VccCurrentEntry 4 }
aal5VccCurrentLengthError OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames
with length error, encountered by the AAL5 interface in the
current 15 minute interval."
::= { aal5VccCurrentEntry 5 }
aal5VccCurrentInputCongestionDropped OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
dropped frames due to congestion, encountered by
the AAL5 interface on the Receive direction
in the current 15 minute interval."
::= { aal5VccCurrentEntry 6 }
aal5VccCurrentOutputCongestionDropped OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
dropped frames due to congestion, encountered by
the AAL5 interface on the Transmit direction
in the current 15 minute interval."
::= { aal5VccCurrentEntry 7 }
-- Interval Table
aal5VccIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF Aal5VccIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The AAL5 Interval table."
::= { atmIfPerformance 6 }
aal5VccIntervalEntry OBJECT-TYPE
SYNTAX Aal5VccIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the AAL5 Interval table."
INDEX { ifIndex, aal5VccVpi, aal5VccVci, aal5VccIntervalNumber }
::= { aal5VccIntervalTable 1 }
Aal5VccIntervalEntry
::= SEQUENCE {
aal5VccIntervalNumber
Integer32,
aal5VccIntervalInFrames
Gauge32,
aal5VccIntervalOutFrames
Gauge32,
aal5VccIntervalUnknownProtocolFrames
Gauge32,
aal5VccIntervalCrcErrors
Gauge32,
aal5VccIntervalLengthError
Gauge32,
aal5VccIntervalInputCongestionDropped
Gauge32,
aal5VccIntervalOutputCongestionDropped
Gauge32
}
aal5VccIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals exist)."
::= { aal5VccIntervalEntry 1 }
aal5VccIntervalInFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames,
encountered by the AAL5 interface in one of the previous
96, individual 15 minute, intervals."
::= { aal5VccIntervalEntry 2 }
aal5VccIntervalOutFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted frames,
encountered by the AAL5 interface in in one of the previous
96, individual 15 minute, intervals."
::= { aal5VccIntervalEntry 3 }
aal5VccIntervalUnknownProtocolFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of frames that were
discarded due to unsupported protocol encapsulation,
encountered by the AAL5 interface in one of the previous
96, individual 15 minute, intervals."
::= { aal5VccIntervalEntry 4 }
aal5VccIntervalCrcErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of AAL5 CPCS PDUs
received with CRC-32 errors, encountered by the AAL5
interface in one of the previous 96, individual 15 minute,
intervals."
::= { aal5VccIntervalEntry 5 }
aal5VccIntervalLengthError OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames
with length error, encountered by the AAL5 interface in one
of the previous 96, individual 15 minute, intervals."
::= { aal5VccIntervalEntry 6 }
aal5VccIntervalInputCongestionDropped OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of dropped frames
due to a congestion, encountered by the AAL5 interface on
the Receive direction in one of the previous 96, individual
15 minute, intervals"
::= { aal5VccIntervalEntry 7 }
aal5VccIntervalOutputCongestionDropped OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of dropped frames
due to a congestion, encountered by the AAL5 interface on
the Transmit direction in one of the previous 96, individual
15 minute, intervals"
::= { aal5VccIntervalEntry 8 }
-- END
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\atmCes.txt
--
--
-- File: v:\doc\rdv\mib\ver485\atm\atmCes.txt
-- Date: 17/01/02
-- By: Ilana Schvetz
-- Last Update: 17-Jan-02 By Ilana Schvetz
--
-- AAL1 statistics. An addition to ATMF-CES (ces.mib)
--
atmCes OBJECT IDENTIFIER ::= {radAtm 9}
atmCesPerformance OBJECT IDENTIFIER ::= {atmCes 1 }
atmCesAal1CurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmCesAal1CurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The AAL1 Current table."
::= { atmCesPerformance 1 }
atmCesAal1CurrentEntry OBJECT-TYPE
SYNTAX AtmCesAal1CurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the AAL1 Current table."
INDEX { atmCesAal1CurrentIfIndex }
::= { atmCesAal1CurrentTable 1 }
AtmCesAal1CurrentEntry ::=
SEQUENCE {
atmCesAal1CurrentIfIndex
Integer32,
atmCesAal1CurrentSeqErrors
Gauge32,
atmCesAal1CurrentHdrErrors
Gauge32,
atmCesAal1CurrentPointerReframes
Gauge32,
atmCesAal1CurrentBufUnderflows
Gauge32,
atmCesAal1CurrentBufOverflows
Gauge32
}
atmCesAal1CurrentIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the AAL1 interface.
It may be ifIndex."
::= { atmCesAal1CurrentEntry 1 }
atmCesAal1CurrentSeqErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Discarded
cells due to wrong sequence number, encountered
by an AAL1 interface in the current 15 minute interval."
::= { atmCesAal1CurrentEntry 2 }
atmCesAal1CurrentHdrErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Discarded
cells due to bad AAL1 header error (including correctable
and uncorrectable CRC, and bad parity), encountered
by an AAL1 interface in the current 15 minute interval."
::= { atmCesAal1CurrentEntry 3 }
atmCesAal1CurrentPointerReframes OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of events in
which a SDT pointer isn't where it is expected to be,
and must be reacquired, encountered by an AAL1 interface
in the current 15 minute interval."
::= { atmCesAal1CurrentEntry 4 }
atmCesAal1CurrentBufUnderflows OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of buffer
underflow events, encountered by an AAL1 interface
in the current 15 minute interval."
::= { atmCesAal1CurrentEntry 5 }
atmCesAal1CurrentBufOverflows OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of buffer
overflow events, encountered by an AAL1 interface
in the current 15 minute interval."
::= { atmCesAal1CurrentEntry 6 }
--Interval Table
atmCesAal1IntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmCesAal1IntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The AAL1 Interval table."
::= { atmCesPerformance 2 }
atmCesAal1IntervalEntry OBJECT-TYPE
SYNTAX AtmCesAal1IntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the AAL1 Interval table."
INDEX { atmCesAal1IntervalIfIndex, atmCesAal1IntervalNumber }
::= { atmCesAal1IntervalTable 1 }
AtmCesAal1IntervalEntry ::=
SEQUENCE {
atmCesAal1IntervalIfIndex
Integer32,
atmCesAal1IntervalNumber
Integer32,
atmCesAal1IntervalSeqErrors
Gauge32,
atmCesAal1IntervalHdrErrors
Gauge32,
atmCesAal1IntervalPointerReframes
Gauge32,
atmCesAal1IntervalBufUnderflows
Gauge32,
atmCesAal1IntervalBufOverflows
Gauge32
}
atmCesAal1IntervalIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the AAL1 interface.
It may be ifIndex."
::= { atmCesAal1IntervalEntry 1 }
atmCesAal1IntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals exist)."
::= { atmCesAal1IntervalEntry 2 }
atmCesAal1IntervalSeqErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Discarded
cells due to wrong sequence number, encountered
by an AAL1 interface in one of the previous 96,
individual 15 minute, intervals."
::= { atmCesAal1IntervalEntry 3 }
atmCesAal1IntervalHdrErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Discarded
cells due to bad AAL1 header error (including correctable
and uncorrectable CRC, plus bad parity), encountered
by an AAL1 interface in one of the previous 96,
individual 15 minute, intervals."
::= { atmCesAal1IntervalEntry 4 }
atmCesAal1IntervalPointerReframes OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of events in
which a SDT pointer isn't where it is expected to be,
and must be reacquired, encountered by an AAL1 interface
in one of the previous 96, individual 15 minute,
intervals."
::= { atmCesAal1IntervalEntry 5 }
atmCesAal1IntervalBufUnderflows OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of buffer
underflow events, encountered by an AAL1 interface
in one of the previous 96, individual 15 minute,
intervals."
::= { atmCesAal1IntervalEntry 6 }
atmCesAal1IntervalBufOverflows OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of buffer
overflow events, encountered by an AAL1 interface
in one of the previous 96, individual 15 minute,
intervals."
::= { atmCesAal1IntervalEntry 7 }
-- Extension for CES Configuration Table
atmCesConfiguration OBJECT IDENTIFIER ::= {atmCes 2 }
atmCesXConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmCesXConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of atmfCESConfTable table."
::= { atmCesConfiguration 1 }
atmCesXConfEntry OBJECT-TYPE
SYNTAX AtmCesXConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Conceptual row in atmfCESConfTable.
A new row is created in this table upon each new CES VCC creation."
AUGMENTS { atmfCESConfEntry }
::= { atmCesXConfTable 1 }
AtmCesXConfEntry ::= SEQUENCE {
atmCesXConfCBRMode INTEGER
}
atmCesXConfCBRMode OBJECT-TYPE
SYNTAX INTEGER {
normal (2),
spaced (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter defines if to use Spaced or Normal CBR.
Normal - TD will be allocated from the policing range (described
in ACE2002 NMS SRS). The PCR is expanded with a constant
value of 30 cell/sec.
Spaced - TD will be allocated from the spacing range (described
in ACE2002 NMS SRS). The PCR and CDVT will be expanded
as described for Normal, and the CES traffic including
the OAM will be spaced out at the TD's PCR.
This mode is used to prevent CDVT violation due to OAM
cell insertion with the CES traffic."
::= { atmCesXConfEntry 1 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\radadsl.txt
--
--Version: 1.0
--Date: 27.03.2001
--By: Yig'al Hachmon
--File: ADSL.txt
--
--Last Update: Yig'al Hachmon 21-May-2008
--ADSL configuration
--wanGen OBJECT IDENTIFIER ::= {radWan 1}
--diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6} (see mpmx.txt)
adslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 10}
adslConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdslConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of ADSL Configuration entries "
::= { adslIf 1 }
adslConfEntry OBJECT-TYPE
SYNTAX AdslConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in adslConfTable"
INDEX { adslConfCnfgIdx,ifIndex }
::= { adslConfTable 1 }
AdslConfEntry ::=
SEQUENCE {
adslConfCnfgIdx Integer32,
adslConfFramingType INTEGER,
adslConfPilotToneRequest INTEGER,
adslConfTrellisCoding INTEGER,
adslConfTransmissionMode INTEGER,
adslConfStandardCompliance INTEGER,
adslConfMaxBitPerBin Integer32,
adslConfTxStartFreqBin Integer32,
adslConfTxEndFreqBin Integer32,
adslConfRxStartFreqBin Integer32,
adslConfRxEndFreqBin Integer32,
adslConfTxPowerAttenuation Integer32,
adslConfPSDMask INTEGER,
adslConfCommand INTEGER
}
adslConfCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
For products that support several configurations,
Set can be performed only to the Temporary Config (=255). "
::= { adslConfEntry 1}
adslConfFramingType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
type2 (2), -- 64Kbits/S overhead
type3 (3), -- 32Kbits/S overhead
type0 (4),
type1 (5),
type3et (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ADSL Frame type "
::= { adslConfEntry 2 }
adslConfPilotToneRequest OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
disable (2), -- PTR is disabled
enable (3) -- PTR is enabled
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter controls Pilot Tone Request (PTR)."
::= { adslConfEntry 3}
adslConfTrellisCoding OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
disable (2), -- Trellis Coding disabled
enable (3) -- Trellis Coding enabled
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter enables/disables Trellis error detection code.
using error detection code may introduce delays."
::= { adslConfEntry 4 }
adslConfTransmissionMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
echoCancellation (2), -- EC
frequencyDivision(3) -- FDM
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter controls transmision mode:
Echo Cancellation is required when both ATU-C an ATU-R use
the same frequency.
Frequency Division (different frequency ranges for ATU-C
and ATU-R) may limit data rate."
::= { adslConfEntry 5}
adslConfStandardCompliance OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
t1Hypen413 (2), -- T1-413
gDotDmt (3), -- G.DMT (Discrete Multi Tones)
multiMode (4), -- Multimode
alcatel1Dot4 (5), -- Alcatel 1.4
alcatel (6), -- Alcatel
adi (7), -- ADI
adsl2 (8),
adsl2Plus (9),
adsl2Auto (10),
adsl2PlusAuto (11)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates standard compliance
G.Lite enables extended ADSL range, ease of installation,
but requires lower rate."
::= { adslConfEntry 6}
adslConfMaxBitPerBin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates maximum number of bits per ADSL Bin.
Each Bin has bandwidth of 4khz.
Range of values for this parameter is 0..15 "
::= { adslConfEntry 7}
adslConfTxStartFreqBin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter controls Transmit Start Bin number.
For ADSL Annex A - range of values is 6 to 31.
For ADSL Annex B - range of values is 33 to 63.
Frequency (in khz unit) is calculated by multiplying this
parameter value by bin bandwidth (4Khz) "
::= { adslConfEntry 8}
adslConfTxEndFreqBin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter controls Transmit End Bin number.
For ADSL Annex A - range of values is 6 to 31.
For ADSL Annex B - range of values is 33 to 63.
requency (in khz unit) is calculated by multiplying this
value by bin bandwidth (4Khz) "
::= { adslConfEntry 9}
adslConfRxStartFreqBin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter controls Receive Start Bin number.
Range of values for this parameter depends on ADSL Annex supported,
and transmisson mode (adslTransmissionMode) selected:
ADSL Annex A and Echo Cancellation (EC) : 6 to 255
ADSL Annex A and Frequency Division (FDM) : 32 to 255
ADSL Annex B and Echo Cancellation (EC) : 33 to 255
ADSL Annex B and Frequency Division (FDM) : 64 to 255
Frequency (in khz unit) is calculated by multiplying this
value by bin bandwidth (4Khz) "
::= { adslConfEntry 10}
adslConfRxEndFreqBin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter controls Receive End Bin number.
Range of values for this parameter depends on ADSL Annex supported,
and transmisson mode (adslTransmissionMode) selected:
ADSL Annex A and Echo Cancellation (EC) : 6 to 255
ADSL Annex A and Frequency Division (FDM) : 32 to 255
ADSL Annex B and Echo Cancellation (EC) : 33 to 255
ADSL Annex B and Frequency Division (FDM) : 64 to 255
Frequency (in khz unit) is calculated by multiplying this
value by bin bandwidth (4Khz) "
::= { adslConfEntry 11}
adslConfTxPowerAttenuation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter controls Transmit Gain in dB units
Range is 0 to 12dB. Resolution is 1 dB"
::= { adslConfEntry 12}
adslConfPSDMask OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
standard (2),
nonOverlapFlat (3),
nonOverlapM1 (4),
nonOverlapM2 (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter controls Power Spectral Density Mask.
This object is applicable only for ADSL2.
(adslConfStandardCompliance is one of the following:
adsl2, adsl2Plus, adsl2Auto, adsl2PlusAuto"
::= { adslConfEntry 13}
adslConfCommand OBJECT-TYPE
SYNTAX INTEGER {
off (1),
restart (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter enables the user to perform commands on ADSL.
off(1) - default state.
After any operation ends, value should be automatically
set to off(1).
restart(2) - restarts line synchronization process.
"
::= { adslConfEntry 14 }
adslStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdslStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Adsl Status entries "
::= { adslIf 2 }
adslStatusEntry OBJECT-TYPE
SYNTAX AdslStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in adslStatusTable"
INDEX { ifIndex }
::= { adslStatusTable 1 }
AdslStatusEntry ::=
SEQUENCE {
adslStatusBitRxRate Gauge32,
adslStatusSelectedStandard INTEGER,
adslStatusOperationalState INTEGER,
adslStatusBitErrorRate Unsigned32,
adslStatusSNRCompensationMode INTEGER,
adslStatusSNRCompensation Unsigned32,
adslStatusSNRCorrection Unsigned32
}
adslStatusBitRxRate OBJECT-TYPE
SYNTAX Gauge32
UNITS "bps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates actual Receive (Downstream)
rate on this channel."
::= { adslStatusEntry 1}
adslStatusSelectedStandard OBJECT-TYPE
SYNTAX INTEGER
{
t1Hypen413AnnexA (2),
gDotDmtAnnexA (3),
multiModeAnnexA (4),
alcatel1Dot4AnnexA (5),
alcatelAnnexA (6),
adiAnnexA (7),
t1Hypen413AnnexB (8),
gDotDmtAnnexB (9),
multiModeAnnexB (10),
alcatel1Dot4AnnexB (11),
alcatelAnnexB (12),
adiAnnexB (13),
adsl2AnnexA (14),
adsl2PlusAnnexA (15),
adsl2AnnexB (16),
adsl2PlusAnnexB (17),
reachAadslAnnexL (18)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates actual Standard
(transsmission mode) chosen after syncronization."
::= { adslStatusEntry 2}
adslStatusOperationalState OBJECT-TYPE
SYNTAX INTEGER
{
idle (1),
discovery (2),
handshake (3),
training (4),
data (5),
fullInit (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates syncronization status."
::= { adslStatusEntry 3}
adslStatusBitErrorRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates the ratio between the number
of erroneous bits to the total bits number.
The value is normalized to 10e-8.
e.g. BER = 10 means BER = 10*10e-8 = 10e-7"
::= { adslStatusEntry 4}
adslStatusSNRCompensationMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
notActive (2),
active (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates whether special SNR compensation mode
has been activated or not."
::= { adslStatusEntry 5}
adslStatusSNRCompensation OBJECT-TYPE
SYNTAX Unsigned32
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates the target-SNR Firmware currently used."
::= { adslStatusEntry 6}
adslStatusSNRCorrection OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates whether the ADSL chip is operating
according to standard ADSL coding gain (auto) or
some other automatic SW configuration (respective to line attenuation).
Units of this parameter are tenths of dB.
Special value of 1000 (=100.0 dB) indicates that 'Auto' coding gain is used."
::= { adslStatusEntry 7}
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\radsdsl.txt
--
--Version: 1.0
--Date: 27.03.2001
--By: Yig'al Hachmon
--File: SDSL.txt
--
--Last Update: Yig'al Hachmon 12-Apr-2001
--SDSL configuration
--wanGen OBJECT IDENTIFIER ::= {radWan 1}
--diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6} (see mpmx.txt)
sdslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 11}
sdslConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF SdslConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of SDSL Configuration entries "
::= { sdslIf 1 }
sdslConfEntry OBJECT-TYPE
SYNTAX SdslConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in sdslConfTable "
INDEX {sdslConfCnfgIdx,ifIndex }
::= { sdslConfTable 1 }
SdslConfEntry ::=
SEQUENCE {
sdslConfCnfgIdx Integer32,
sdslConfRateAquisition INTEGER,
sdslConfBaudRate INTEGER,
sdslConfMode INTEGER
}
sdslConfCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
For products that support several configurations, Set can be performed
only to the Temporary Config (=255). "
::= { sdslConfEntry 1}
sdslConfRateAquisition OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
autoNegotiate (2),
fixed (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SDSL Rate Aquisition mode
Default value = fixed."
::= { sdslConfEntry 2 }
sdslConfBaudRate OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
r144kbps (2),
r748kbps (3),
r1168kbps (4),
r1550kbps (5),
r2320kbps (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SDSL baud rate. Not applicable if rate aquisition is AutoNegotiation.
Default value = r144kbps"
::= { sdslConfEntry 3 }
sdslConfMode OBJECT-TYPE
SYNTAX INTEGER {
coe (1), -- HTU-C
cpe (2) -- HTU-R
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SDSL mode - COE (HTU-C) or CPE (HTU-R)
Default value = COE"
::= { sdslConfEntry 4 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\radshdsl.txt
--
--Version: 1.0
--Date: 9 Sep 02
--By: Yig'al Hachmon
--File: radshdsl.txt
--
--Last Update: 19-Aug-2008 by Yig'al Hachmon
--SHDSL configuration
--wanGen OBJECT IDENTIFIER ::= {radWan 1}
--diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6} (see mpmx.txt)
shdslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 12}
radHdsl2ShdslEvents OBJECT IDENTIFIER ::= {shdslIf 0}
-- Segment Endpoint Current Status/Performance Group
shdslEndpointCurrTable OBJECT-TYPE
SYNTAX SEQUENCE OF ShdslEndpointCurrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of hdsl2ShdslEndpointCurrTable of rfc3276
It contains current status and performance information
for segment endpoints in HDSL2/SHDSL Lines. As with other
tables in this MIB indexed by ifIndex, entries in this table
MUST be maintained in a persistent manner."
::= { shdslIf 1 }
shdslEndpointCurrEntry OBJECT-TYPE
SYNTAX ShdslEndpointCurrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the shdslEndpointCurrTable. Each entry
contains status and performance information relating to a
single segment endpoint. It is indexed by the ifIndex of the
HDSL2/SHDSL line, the UnitId of the associated unit, the side
of the unit, and the wire-pair of the associated modem."
AUGMENTS {hdsl2ShdslEndpointCurrEntry}
::= { shdslEndpointCurrTable 1 }
ShdslEndpointCurrEntry ::=
SEQUENCE
{
hdsl2ShdslEndpointCurrRcvGain Integer32,
hdsl2ShdslEndpointCurrTransPower Integer32,
hdsl2ShdslEndpointCurrPowerBO Integer32,
hdsl2ShdslEndpointCurrLineStatus INTEGER,
hdsl2ShdslEndpointCurrOpState BITS,
hdsl2ShdslEndpointAccumulatedTimeElapsed TimeTicks,
hdsl2ShdslEndpointCurrPsd INTEGER,
hdsl2ShdslEndpointValidIntervals Unsigned32,
hdsl2ShdslEndpointValidDaysIntervals Unsigned32
}
hdsl2ShdslEndpointCurrRcvGain OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current receive gain in hundredth of dB."
::= { shdslEndpointCurrEntry 1 }
hdsl2ShdslEndpointCurrTransPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current transmit power in tenth of dBm."
::= { shdslEndpointCurrEntry 2 }
hdsl2ShdslEndpointCurrPowerBO OBJECT-TYPE -- added by RAD
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current transceiver actual power backoff from 0dB to 31dB."
::= { shdslEndpointCurrEntry 3 }
hdsl2ShdslEndpointCurrLineStatus OBJECT-TYPE -- added by RAD
SYNTAX INTEGER
{
noSync (2),
sync (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current line synchronization status."
::= { shdslEndpointCurrEntry 4 }
hdsl2ShdslEndpointCurrOpState OBJECT-TYPE -- added by RAD
SYNTAX BITS
{
idleMode(0),
dataMode(1),
bootUpload(2),
bootUploadDone(3),
startupHandshakeInProgress(4),
startupTrainingInProgress(5),
framerSyncInProgress(6),
localAnalogLoopbackInProgress(7),
remoteCoreLoopbackInProgress(8),
localDigitalLoopbackInProgress(9),
spectrumTestInProgress(10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational state."
::= { shdslEndpointCurrEntry 5 }
hdsl2ShdslEndpointAccumulatedTimeElapsed OBJECT-TYPE -- added by RAD
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time (in hundredths of a second) since the
accumulated counters were last re-initialized:
Accumulated counters are hdsl2ShdslEndpointES,
hdsl2ShdslEndpointSES, hdsl2ShdslEndpointCRCanomalies
hdsl2ShdslEndpointLOSWS, and hdsl2ShdslEndpointUAS."
::= { shdslEndpointCurrEntry 6 }
hdsl2ShdslEndpointCurrPsd OBJECT-TYPE
SYNTAX INTEGER
{
asymmetric(2),
symmetric(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates use of symmetric/asymmetric PSD (Power
Spectral Density) Mask for the associated SHDSL Line."
::= { shdslEndpointCurrEntry 7 }
hdsl2ShdslEndpointValidIntervals OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of previous 15 minutes intervals
for which valid data was collected."
::= { shdslEndpointCurrEntry 8 }
hdsl2ShdslEndpointValidDaysIntervals OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of previous Days intervals
for which valid data was collected."
::= { shdslEndpointCurrEntry 9 }
shdslEndpointMaintTable OBJECT-TYPE
SYNTAX SEQUENCE OF ShdslEndpointMaintEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table supports maintenance operations (eg. loopbacks)
to be performed on HDSL2/SHDSL segment endpoints. This table
contains live data from equipment. As such, it is NOT
persistent."
::= { shdslIf 2 }
shdslEndpointMaintEntry OBJECT-TYPE
SYNTAX ShdslEndpointMaintEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the hdsl2ShdslEndpointMaintTable. Each entry
corresponds to a single segment endpoint, and is indexed by the
ifIndex of the HDSL2/SHDSL line, the UnitId of the associated
unit and the side of the unit."
INDEX { ifIndex, hdsl2ShdslInvIndex, hdsl2ShdslEndpointSide }
::= { shdslEndpointMaintTable 1 }
ShdslEndpointMaintEntry ::=
SEQUENCE
{
shdslMaintPowerBackOff INTEGER
}
shdslMaintPowerBackOff OBJECT-TYPE
SYNTAX INTEGER
{
default(1),
enhanced(2),
disabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the receiver at the associated
segment endpoint to operate in default or enhanced power
backoff mode.
powerbackoff may also be disabled"
::= { shdslEndpointMaintEntry 1 }
-- Span Configuration Profile Group
shdslSpanConfProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF ShdslSpanConfProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table supports definitions of span configuration
profiles for SHDSL lines. HDSL2 does not support these
configuration options. This table MUST be maintained
in a persistent manner."
::= { shdslIf 3 }
shdslSpanConfProfileEntry OBJECT-TYPE
SYNTAX ShdslSpanConfProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry corresponds to a single span configuration
profile. Each profile contains a set of span configuration
parameters. The configuration parameters in a profile are
applied to those lines referencing that profile (see the
hdsl2ShdslSpanConfProfile object). Profiles may be
created/deleted using the row creation/deletion mechanism
via hdsl2ShdslSpanConfProfileRowStatus. If an active
entry is referenced in hdsl2ShdslSpanConfProfile, the
entry MUST remain active until all references are removed."
AUGMENTS {hdsl2ShdslSpanConfProfileEntry}
::= { shdslSpanConfProfileTable 1 }
ShdslSpanConfProfileEntry ::=
SEQUENCE
{
hdsl2ShdslSpanConfEocCompatible INTEGER,
hdsl2ShdslSpanConfAsymmetricPSDRate INTEGER,
hdsl2ShdslSpanConfWireInterfaceUsed INTEGER,
hdsl2ShdslSpanConfHandshake INTEGER
}
hdsl2ShdslSpanConfEocCompatible OBJECT-TYPE -- Added by RAD
SYNTAX INTEGER
{
proprietary (2),
standard (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicate if device supports only
standard EOC messages or also proprietary messages."
::= { shdslSpanConfProfileEntry 1 }
hdsl2ShdslSpanConfAsymmetricPSDRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
asymmetricR1 (2),
asymmetricR2 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates line rate when
rfc3276.hdsl2ShdslSpanConfPSD value is asymmetric(2).
Seleceted rate depends on transmission mode -
specified in Annex A or B of G.991.2.
For Annex A;
R1 selects the 776 or 784 kbit/s
R2 selects the 1544 or 1552 kbit/s
For Annex B ;
R1 selects the 2312 kbit/s
R2 selects the 2056 kbit/s "
::= { shdslSpanConfProfileEntry 2 }
hdsl2ShdslSpanConfWireInterfaceUsed OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
twoWires (2),
fourWires (3),
autoDetection (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enable user to configure SHDSL port with 4 wires
to use 2 or 4 wires, or to auto detect far end number of wires"
::= { shdslSpanConfProfileEntry 3 }
hdsl2ShdslSpanConfHandshake OBJECT-TYPE
SYNTAX INTEGER
{
automatic (1),
g994dot1rev2001 (2) -- G994.1 02/2001
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Handshake Procedure."
::= { shdslSpanConfProfileEntry 4 }
hdsl2ShdslIfConf OBJECT IDENTIFIER ::= { shdslIf 4 }
--Interface configuration with Configuration index
hdsl2ShdslIfConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hdsl2ShdslIfConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table enables configuration of HDSL2/SHDSL interfaces
per configuration index.
Write operation for products supporting Active+Temp configurations,
is possible only on the Temp configuration(255)."
::= { hdsl2ShdslIfConf 1 }
hdsl2ShdslIfConfEntry OBJECT-TYPE
SYNTAX Hdsl2ShdslIfConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the hdsl2ShdslIfConfTable. "
INDEX { hdsl2ShdslIfConfIdx, ifIndex, hdsl2ShdslSideIdx}
::= { hdsl2ShdslIfConfTable 1 }
Hdsl2ShdslIfConfEntry ::=
SEQUENCE
{
hdsl2ShdslIfConfIdx Integer32,
hdsl2ShdslSideIdx INTEGER,
hdsl2ShdslMaxBw INTEGER,
hdsl2ShdslPwrBackoff INTEGER,
hdsl2ShdslTxMode INTEGER,
hdsl2ShdslAttenuationThreshold Integer32,
hdsl2ShdslSnrMarginThreshold Integer32,
hdsl2ShdslTs0OverDsl INTEGER,
hdsl2ShdslMode INTEGER,
hdsl2ShdslTsCompactionMode INTEGER,
hdsl2ShdslEocEnable INTEGER,
hdsl2ShdslFar1stIfNumOfTSs Unsigned32,
hdsl2ShdslFarEndDevice INTEGER,
hdsl2ShdslPwrBackoffDb Integer32,
hdsl2ShdslFarEndMuxTsa OCTET STRING
}
hdsl2ShdslIfConfIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
Write operation for products supporting Active+Temp configurations,
is allowed to Temporary configuration only. "
::= {hdsl2ShdslIfConfEntry 1}
hdsl2ShdslSideIdx OBJECT-TYPE
SYNTAX INTEGER {
nearEnd(2),
farEnd (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Side of the managed object: Near-End
or Far-End."
::= {hdsl2ShdslIfConfEntry 2}
hdsl2ShdslMaxBw OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
r192 (2),
r256 (3),
r320 (4),
r384 (5),
r448 (6),
r512 (7),
r576 (8),
r640 (9),
r704 (10),
r768 (11),
r832 (12),
r896 (13),
r960 (14),
r1024 (15),
r1088 (16),
r1152 (17),
r1216 (18),
r1280 (19),
r1344 (20),
r1408 (21),
r1472 (22),
r1536 (23),
r1600 (24),
r1664 (25),
r1728 (26),
r1792 (27),
r1856 (28),
r1920 (29),
r1984 (30),
r2048 (31)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum BW (Bandwidth) of the Shdsl Line, in Kbps units.
Respective Max No. of TSs = Max. Rate/64
This object can be Set only for a Central (xtuC) unit."
::= {hdsl2ShdslIfConfEntry 3}
hdsl2ShdslPwrBackoff OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
enhanced(2), -- enabled
disabled (3) -- added by RAD
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the receiver at the associated
segment endpoint to enable/disable power backoff mode.
This object is similar to hdsl2ShdslMaintPowerBackOff, but per
configuration. Therefore, the order of the enum values is the same. "
::= {hdsl2ShdslIfConfEntry 4}
hdsl2ShdslTxMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
annexA (2),
annexB (3),
annexG (4),
annexF (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the Transmission Mode for the SHDSL Line.
Normally, This object can be Set only for a Central (xtuC) unit."
::= { hdsl2ShdslIfConfEntry 5}
hdsl2ShdslAttenuationThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the Attentuation alarm threshold.
0=Off
Valid values: 0..127 ."
::= { hdsl2ShdslIfConfEntry 6}
hdsl2ShdslSnrMarginThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the SNR margin alarm threshold.
0=Off
Valid values: 0..15 ."
::= { hdsl2ShdslIfConfEntry 7}
hdsl2ShdslTs0OverDsl OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
looped (2),
transparent (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the way TS0 will be treated over the SHDSL Line.
looped - looped inside
transparent - sent transparently over the DSL Line.
This object can be Set only for a Central (xtuC) unit."
::= { hdsl2ShdslIfConfEntry 8}
hdsl2ShdslMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
stuC (2),
stuR (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is relevant only for the Near-End device.
stuC - Central
stuR - Remote ."
::= { hdsl2ShdslIfConfEntry 9}
hdsl2ShdslTsCompactionMode OBJECT-TYPE
SYNTAX INTEGER
{
noCompaction (1),
noMapping (2),
withMapping (3),
lowTsMapping (4),
spareMapping (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures how TSs will be compacted over the SHDSL Line.
In both mapping cases (2),(3), only the TSs connected on the E1 line will be
transferred over the SHDSL Line
noCompaction - the whole E1 BW is reserved on the SHDSL Line,
even if only part of the TSs are actually connected.
noMapping - there is no mapping between the E1 TSs and the SHDSL frame TSs.
Therefore, E1 connected TSs are ordered in ascending order (e.g
E1 TSs 2, 16, 20 will occupy places 1, 2, 3 in SHDSL Line).
In this case, if user wants to add connection for
a TS that is lower than the existing ones on SHDSL,
the TSs that are higher will have to move.
That causes breaks in service for the moved TSs.
(e.g if E1 TS8 is added in the above case,
TSs 16 and 20 will move, so that by the
end of this process, the E1 TSs 2, 8, 16, 20 will
be ordered in SHDSL frame as 1, 2, 3, 4).
withMapping - there is a mapping between the E1 TSs and the SHDSL frame TSs.
Therefore, if some TSs were connected and then user wants to add
additional E1 TSs, there is no need to move the existing TSs of the
SHDSL frame. The additional TSs will be added AFTER the existing ones,
or in gaps created by E1 TSs removed by user. The main thing is that
the existing TSs will NOT be moved and so, their service will not be
damaged by the addition or removal of E1 TS connections.
lowTsMapping - the first 2 TSs are used for Signaling (TS16) and Dedicated TS
if relevant. The payload starts afterwards, unmapped (according to
E1 connected TSs order). This will ensure that Signaling and
Dedicated TS will continue to function also when new TSs are
connected. User will still get service breaks when TSs are moved.
spareMapping - applicable only for MP-2100/2104 cards. It should be selected only
when working vs. a MP-2100.2104. It resembles the noMapping option,
but it contains Spare TSs for unconnected TSs. These Spare TSs
will prevent service breaks upon added connections, because these
will be selected from the Spare existing TSs."
::= { hdsl2ShdslIfConfEntry 10}
hdsl2ShdslEocEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures whether EOC protocol is supported by the Far-End
device working with this port."
::= { hdsl2ShdslIfConfEntry 11}
hdsl2ShdslFar1stIfNumOfTSs OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the number of TSs of the SHDSL line
that belong to the 1st Interface of the Far-End device, where
1st means that these TSs are first on the SHDSL line.
It is applicable only for Near-End instance and only when Far-End
is an ASMi-52 SA unit having Agent and Mux configuration.
SHDSL TSs are arranged so that all TSs of a Far interface are together
at the beginning and afterwards all TSs of the other Far interface.
The assumption is that only 2 user interfaces exist in the Far End unit.
Examples:
- When ASMi-52 has E1+ETH or E1+V.35 user interfaces, this object
represents the number of TSs assigned to the E1 interface.
They will be first on the SHDSL TSs.
Rest of the SHDSL TSs are for the other interface.
- When ASMi-52 has ETH+V.35 user interfaces, this object
represents the number of TSs assigned to the ETH interface.
They will be first on the SHDSL TSs.
Rest of the SHDSL TSs are for the V.35 interface.
Valid values: 0..32, 255.
255=NA "
::= { hdsl2ShdslIfConfEntry 12}
hdsl2ShdslFarEndDevice OBJECT-TYPE
SYNTAX INTEGER
{
other (2),
mpComponent (3),
asmi52SingleIf (4),
asmi52E1AndData (5),
asmi52E1AndEth (6),
asmi52EthAndData (7),
fcdip (8),
dxc (9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Far-End device.
It is used for 2 purposes:
- in order to know if EOC is used (EOC is used only when the device
is any of the ASMi52 options: (4)..(7))
- in order to know how to work vs Far-End device, because Megaplex
uses different SHDSL component than other devices. mpComponent(3)
means that Far-End device uses same component as Megaplex. All the
rest use a different component.
other(2) - none of the other options.
mpComponent(3) - for Megaplex or other future device having the same
component as MP.
asmi52SingleIf (4) - ASMi-52 with a Single user interface.
asmi52E1AndData(5), asmi52E1AndEth(6), asmi52EthAndData (7),are
when Far-End unit is ASMi-52 V>=2.5 and the device has more than one
user interface. User should select the combination known to exist in
the Far-End unit.
Data - indicates an interface of V.35, X.21, RS-530, etc...
fcdip - includes both FCD-IP and FCD-IP/M
dxc - includes DXC-30, DXC-30E, DXC-10A, DXC-8R and New. "
::= { hdsl2ShdslIfConfEntry 13}
hdsl2ShdslPwrBackoffDb OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the Power Backoff (in dB) of the
receiver, at the associated segment endpoint.
0=Off
Valid values: 0..31 ."
::= { hdsl2ShdslIfConfEntry 14}
hdsl2ShdslFarEndMuxTsa OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents Assignment of E1 TSs to Far-End MUX Interfaces.
It is relevant only when hdsl2ShdslSideIdx=nearEnd(2), when for the
Near-End device, hdsl2ShdslMode=stuC(2)AND hdsl2ShdslFarEndDevice=(5),(6)or(7).
Each Octet is divided in 2 nibbles. Each nibble represents a Near-End E1 TS
and indicates to which interface of the Far-End device this TS will be
assigned.
The nibble values are as follows:
0000 - no interface
0001 - E1 interface
0010 - ETH interface
0011 - Data interface (V.35, X.21, RS-530, etc..)
Rest - not used
Octet 1: TS1, TS2 (TS1 = Most nibble)
Octet 2: TS3, TS4 (TS3 = Most nibble)
Octet 3: TS5, TS6 (TS5 = Most nibble)
...
Octet 12: TS23, TS24 (TS23 = Most nibble)
...
Octet 16: TS31, TS32 (TS31 = Most nibble ; TS32 will be always empty )
Only TSs that are connected for E1 port of Near-End can be assigned to
a Far-End Interface."
::= { hdsl2ShdslIfConfEntry 15}
-- SHSDL Notifications
--SHDSL EOC LOOPBACK TOWARDS NETWORK
radHdsl2ShdslLoopBackTrap NOTIFICATION-TYPE
OBJECTS { alarmSeverity,alarmState,ifAlias }
STATUS current
DESCRIPTION
"This notification indicates that a remote loopback
has been activated on the Embedded Operations Channel (EOC) of the SHDSL
link."
::= { radHdsl2ShdslEvents 1 }--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\services.txt
--
-- File: Services.txt
services OBJECT IDENTIFIER ::= { radGen 3}
--Weighted Fair Queueing (WFQ) Table
wfq OBJECT IDENTIFIER ::= { services 1}
wfqTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfqEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table allows user to define several
WFQ tables per output port.
WFQ supports flows with different bandwidth requirements
by giving each queue a weight that assigns it
a different percentage of output port bandwidth.
When Weighted Fair Queuing is used,
it is possible to precisely attribute bandwidth
partitioning among the queues.
When there is congestion, each class (queue)
is not allowed to use more bandwidth than the amount
allocated to it."
::= { wfq 1 }
wfqEntry OBJECT-TYPE
SYNTAX WfqEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Weighted Fair Queueing table."
INDEX {wfqCnfgIdx, wfqPrtIdx,wfqTblIdx, wfqQueueIdx }
::= { wfqTable 1 }
WfqEntry ::=
SEQUENCE {
wfqCnfgIdx Integer32,
wfqPrtIdx Integer32,
wfqTblIdx Integer32,
wfqQueueIdx Integer32,
wfqRowStatus RowStatus,
wfqWeightValue Integer32,
wfqSchedulingMode INTEGER,
wfqMinRateAbsolute Unsigned32,
wfqMaxPacketSize Unsigned32
}
wfqCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Idx of the Agent Cnfg the following
objects refer.
255=Temporary Cnfg (when relevant,
Set is done only to this configuration).
For Agents that support only one configuration,
this object will be constant=1. "
::= { wfqEntry 1 }
wfqPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates a unique port or interface number,
for which Weighted Fair Queueing table is applicable .
For numbering, see product's spec.
For some products, the numbering can equal ifIndex.
Value of 255 (not applicable) refer to system level queue"
::= { wfqEntry 2 }
wfqTblIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates which Weighted Fair Queueing (WFQ)
Table is being used. There can be several tables.
For FCD-155 User will select which one will be used
for a virtual concatenation group.Valid values are 1,2"
::= { wfqEntry 3 }
wfqQueueIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates a queue index.
For FCD-155, valid queues are 1..3.
The 4th queue is not in MIB.
Its weight will be RO, Calculated according to
the sum of the 3 first queues."
::= { wfqEntry 4 }
wfqRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables Creation/Deletion of
rows in the WFQ table.
For FCD-155, rows are not created nor destroyed by user."
::= { wfqEntry 5 }
wfqWeightValue OBJECT-TYPE
SYNTAX Integer32 (0..100)
UNITS "%"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates a relative weight value.
User should make sure that the sum of
values for all queues will not exceed 100%
(sum should be BELOW 100% in order
to leave some BW percentage for last queue)
Note that when this attribute is being used, the wfqMinRateAbsolute attribute is NA."
::= { wfqEntry 6 }
wfqSchedulingMode OBJECT-TYPE
SYNTAX INTEGER {
disable (2), -- Priority Queue
enable (3) -- WFQ
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls which scheduling mode is used:
Weighted Fair Queuing (WFQ) scheme or priority Queue (Strict Priority)."
::= { wfqEntry 7 }
wfqMinRateAbsolute OBJECT-TYPE
SYNTAX Unsigned32
UNITS "Kbps"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The minimum absolute rate, in kbps,
that should be allocated to this queue.
If the value is zero, then there is effectively
no minimum rate guarantee.
If the value is non-zero, then the servicing of
this queue in at least this rate is assured.
Note that when this attribute is being used, the wfqWeightValue attribute is NA."
::= { wfqEntry 8 }
wfqMaxPacketSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The size of the largest packet which can be received
on this queue, specified in octets.
Packets larger than this size will be discarded."
::= { wfqEntry 9}
-- Differential Services Code Point Mapping
Dscp ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"A Differentiated Services Code-Point that may be used for
marking a traffic stream."
REFERENCE
"RFC 2474, RFC 2780"
SYNTAX Integer32 (0..63)
dscpMapping OBJECT IDENTIFIER ::= {services 2}
dscpMappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF DscpMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Mapping of DSCP value to a regenerated priority level."
::= { dscpMapping 1 }
dscpMappingEntry OBJECT-TYPE
SYNTAX DscpMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in dscpMappingTable."
INDEX { dscpMappingCnfgIdx,dscpMappingDscpIdx }
::= { dscpMappingTable 1 }
DscpMappingEntry ::=
SEQUENCE {
dscpMappingCnfgIdx Integer32,
dscpMappingDscpIdx Dscp,
dscpMappingRegenPriority Integer32
}
dscpMappingCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Idx of the Agent Cnfg the following
objects refer to.
255=Temporary Cnfg (when relevant, Set is done only
to this configuration).
For Agents that support only one configuration,
this object will be constant=1.
This object can be used to carry additional indexing
(e.g port index) when needed."
::= { dscpMappingEntry 1 }
dscpMappingDscpIdx OBJECT-TYPE
SYNTAX Dscp
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" DSCP value of the incoming IP packet"
::= { dscpMappingEntry 2 }
dscpMappingRegenPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Regenerated Priority level the
incoming DSCP value is mapped to.
For FCD-155, valid values are 0,1,2,3"
::= { dscpMappingEntry 3 }
-- IfTeQos - Traffic Engineering Quality of Service Interface
ifTeQos OBJECT IDENTIFIER ::= { services 3 }
ifTeQosTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfTeQosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The TE QOS Interface Table."
::= { ifTeQos 1 }
ifTeQosEntry OBJECT-TYPE
SYNTAX IfTeQosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the TE QOS Interface table."
INDEX { ifTeQosIdx1, ifTeQosIdx2, ifTeQosIdx3 }
::= { ifTeQosTable 1 }
IfTeQosEntry ::=
SEQUENCE {
ifTeQosIdx1 Integer32,
ifTeQosIdx2 Integer32,
ifTeQosIdx3 Integer32,
ifTeQosParam OCTET STRING,
ifTeQosParam2 OCTET STRING,
ifTeQosStatus INTEGER
}
ifTeQosIdx1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the 1st Index of the table."
::= { ifTeQosEntry 1 }
ifTeQosIdx2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the 2nd Index of the table."
::= { ifTeQosEntry 2 }
ifTeQosIdx3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the 3rd Index of the table."
::= { ifTeQosEntry 3 }
ifTeQosParam OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for QOS attributes
of the entry's entities."
::= { ifTeQosEntry 4 }
ifTeQosParam2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for 2nd group QOS attributes
of the entry's entities."
::= { ifTeQosEntry 5 }
ifTeQosStatus OBJECT-TYPE
SYNTAX INTEGER
{ active (1),
createAndGo (4),
destroy (6) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to create, activate and
destroy entries of this table."
::= { ifTeQosEntry 6 }
portQos OBJECT IDENTIFIER ::= { services 4 }
prtPriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtPriorityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table - Parameters per port per Priority ."
::= {portQos 1}
prtPriorityEntry OBJECT-TYPE
SYNTAX PrtPriorityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtPriorityIdx1, prtPriorityPrtIdx, prtPriorityIdx}
::= { prtPriorityTable 1}
PrtPriorityEntry ::=
SEQUENCE {
prtPriorityIdx1 Integer32,
prtPriorityPrtIdx Integer32,
prtPriorityIdx Integer32,
prtPriorityIngressRateLimit Integer32
}
prtPriorityIdx1 OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg(1..255) being
accessed ; Idx of 255 relates to the TmpCnfg. or any other Index."
::= { prtPriorityEntry 1}
prtPriorityPrtIdx OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates a unique Port Index.
Refer to device specification for port Index."
::= { prtPriorityEntry 2}
prtPriorityIdx OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Traffic Priority Index."
::= { prtPriorityEntry 3}
prtPriorityIngressRateLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum rate permitted at Ingress of
this port with this Traffic Priority, in Kbps."
::= { prtPriorityEntry 4}
prtQosTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtQosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Port QoS (Quality of Service) table."
::= { portQos 2 }
prtQosEntry OBJECT-TYPE
SYNTAX PrtQosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtQosIdx, prtQosPrtIdx, prtQosDirection }
::= { prtQosTable 1 }
PrtQosEntry ::=
SEQUENCE {
prtQosIdx Unsigned32,
prtQosPrtIdx Unsigned32,
prtQosDirection INTEGER,
prtQosRateLimitPacketType INTEGER,
prtQosRateLimitCIR Unsigned32,
prtQosRateLimitCBS Unsigned32,
prtQosRateLimitEIR Unsigned32,
prtQosRateLimitEBS Unsigned32
}
prtQosIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The first index of the table.
This attribute might indicate the Idx of the Cnfg (1..255) being
accessed ; Idx of 255 relates to the TmpCnfg or any other Index."
::= { prtQosEntry 1 }
prtQosPrtIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates a unique Port Index.
Refer to device specification for port Index."
::= { prtQosEntry 2 }
prtQosDirection OBJECT-TYPE
SYNTAX INTEGER {
all (1),
ingress (2),
egress (3)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the port's QoS Direction."
::= { prtQosEntry 3 }
prtQosRateLimitPacketType OBJECT-TYPE
SYNTAX INTEGER {
all (1),
bcastAndMcastAndFloodedUcast (2), -- BroadCast + Multicast + Flooded Unicast
bcastAndMcast (3), -- BroadCast + Multicast
bcast (4) -- BroadCast
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Type of Packets on which Rate Limitation is applied."
::= { prtQosEntry 4 }
prtQosRateLimitCIR OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the port's CIR (Committed Information Rate) in Kbps.
Value=0 represents best effort."
::= { prtQosEntry 5 }
prtQosRateLimitCBS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the port's CBS (Committed Burst Size) in KB.
Value=0 represents best effort."
::= { prtQosEntry 6 }
prtQosRateLimitEIR OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the port's EIR (Excess Information Rate) in Kbps."
::= { prtQosEntry 7 }
prtQosRateLimitEBS OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the port's EBS (Excess Burst Size) in KB."
::= { prtQosEntry 8 }
prtTrafficClass OBJECT IDENTIFIER ::= { services 5 }
portTrafficClassTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortTrafficClassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Mapping of port to Traffic Class level."
::= { prtTrafficClass 1 }
portTrafficClassEntry OBJECT-TYPE
SYNTAX PortTrafficClassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in portTrafficClassTable."
INDEX { portTrafficClassIdx1, portTrafficClassPortIdx }
::= { portTrafficClassTable 1 }
PortTrafficClassEntry ::=
SEQUENCE {
portTrafficClassIdx1 Integer32,
portTrafficClassPortIdx Integer32,
portTrafficClass Integer32
}
portTrafficClassIdx1 OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This attribute indicates the 1st index of the table.
This may be the Idx of the Cnfg(1..255) being accessed;
Idx of 255 relates to the TmpCnfg, or any other Index."
::= { portTrafficClassEntry 1 }
portTrafficClassPortIdx OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates a unique Port Index.
Refer to device specification for port Index."
::= { portTrafficClassEntry 2 }
portTrafficClass OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Traffic Class level of this port."
::= { portTrafficClassEntry 3 }
--------------------------
-- Services Definitions
--------------------------
serviceTable OBJECT-TYPE
SYNTAX SEQUENCE OF ServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of services."
::= { services 6 }
serviceEntry OBJECT-TYPE
SYNTAX ServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Service Table."
INDEX { ifIndex, flowIndex, serviceIndex }
::= { serviceTable 1 }
ServiceEntry ::= SEQUENCE {
flowIndex Unsigned32,
serviceIndex Unsigned32,
serviceRowStatus RowStatus,
serviceName SnmpAdminString,
serviceBwProfileId Unsigned32
}
flowIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the Flow ID the service is associated to."
::= { serviceEntry 1 }
serviceIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the Service ID - according to the CoS."
::= { serviceEntry 2 }
serviceRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute is used to create a new row or to delete an existing row
in the table."
::= { serviceEntry 3 }
serviceName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute defines the service name."
::= { serviceEntry 4 }
serviceBwProfileId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable holds the index of the Ingress BW profile assigned
to that service."
::= { serviceEntry 5 }
--EVC CoS Table
evcCosTable OBJECT-TYPE
SYNTAX SEQUENCE OF EvcCosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines mapping of Ethernet Virtual Connection
(EVC) ID to Class of Service (CoS) ID "
::= {services 7}
evcCosEntry OBJECT-TYPE
SYNTAX EvcCosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {evcCosCnfgIdx,evcCosEvcIdx}
::= { evcCosTable 1}
EvcCosEntry ::=
SEQUENCE {
evcCosCnfgIdx Unsigned32,
evcCosEvcIdx Unsigned32,
evcCosRowStatus RowStatus,
-- evcCosServiceProfileIdx Unsigned32,
evcCosEvcName SnmpAdminString,
evcCosSpVlanId Unsigned32
}
evcCosCnfgIdx OBJECT-TYPE
SYNTAX Unsigned32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg(1..255) being
accessed ; Idx of 255 relates to the TmpCnfg."
::= {evcCosEntry 1}
evcCosEvcIdx OBJECT-TYPE
SYNTAX Unsigned32 (1..4095)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This attribute indicates EVC Id."
::= {evcCosEntry 2}
evcCosRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute allows to create/delete a row in this table."
::= {evcCosEntry 3}
-- ::= {evcCosEntry 4} (reserved)
evcCosEvcName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A string that identifies the EVC. It should be unique
in the Maintenance Domain (i.e., in the managed network)
Used as MEG ID field in OAM messages."
::= {evcCosEntry 5}
evcCosSpVlanId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the SP (Service Provider) VLAN used when sending
an OAM message for the specified EVC."
::= {evcCosEntry 6}
-----------------------------------
-- Service Statistics Definitions
-----------------------------------
serviceStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF ServiceStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Service statistics table."
::= { services 8 }
serviceStatEntry OBJECT-TYPE
SYNTAX ServiceStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Service Statistics Table. "
INDEX { ifIndex, flowIndex, serviceIndex, serviceStatDirection }
::= { serviceStatTable 1 }
ServiceStatEntry ::= SEQUENCE {
serviceStatDirection INTEGER,
srvForwardGreenPackets Gauge32,
srvForwardGreenPacktesOverflow Gauge32,
srvForwardYellowPackets Gauge32,
srvForwardYellowPacketsOverflow Gauge32,
srvDiscardGreenPacket Gauge32,
srvDiscardGreenPacketOverflow Gauge32,
srvDiscardYellowRedPackets Gauge32,
srvDiscardYellowRedPacketsOverflow Gauge32,
srvForwardGreenBytes Gauge32,
srvForwardGreenBytesOverflow Gauge32,
srvForwardYellowBytes Gauge32,
srvForwardYellowBytesOverflow Gauge32,
srvDiscardGreenBytes Gauge32,
srvDiscardGreenBytesOverflow Gauge32,
srvDiscardYellowRedBytes Gauge32,
srvDiscardYellowRedBytesOverflow Gauge32,
srvResetStatsCmd INTEGER,
srvDiscardYellowPackets Gauge32,
srvDiscardYellowPacketsOverflow Gauge32,
srvDiscardYellowBytes Gauge32,
srvDiscardYellowBytesOverflow Gauge32,
srvDiscardRedPackets Gauge32,
srvDiscardRedPacketsOverflow Gauge32,
srvDiscardRedBytes Gauge32,
srvDiscardRedBytesOverflow Gauge32
}
serviceStatDirection OBJECT-TYPE
SYNTAX INTEGER
{
upstream (1),
downstream (2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The direction in wich the measurement is taken."
::= { serviceStatEntry 1 }
srvForwardGreenPackets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the counted number of forwarded packets
that where marked Green."
::= { serviceStatEntry 2 }
srvForwardGreenPacktesOverflow OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the number of times that the
forwardGreenPackets counter has overflowed."
::= { serviceStatEntry 3 }
srvForwardYellowPackets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the counted number of forwarded packets
that where marked Yellow."
::= { serviceStatEntry 4 }
srvForwardYellowPacketsOverflow OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the number of times that the
forwardYellowPackets counter has overflowed."
::= { serviceStatEntry 5 }
srvDiscardGreenPacket OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the counted number of discarded packets
that where marked Green."
::= { serviceStatEntry 6 }
srvDiscardGreenPacketOverflow OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the number of times that the
discardGreenPacket counter has overflowed."
::= { serviceStatEntry 7 }
srvDiscardYellowRedPackets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the counted number of discarded packets
that where marked Yellow or Red."
::= { serviceStatEntry 8 }
srvDiscardYellowRedPacketsOverflow OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the number of times that the
discardYellowRedPackets counter has overflowed."
::= { serviceStatEntry 9 }
srvForwardGreenBytes OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the counted number of forwarded bytes
that where marked Green."
::= { serviceStatEntry 10 }
srvForwardGreenBytesOverflow OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the number of times that the
forwardGreenBytes counter has overflowed."
::= { serviceStatEntry 11 }
srvForwardYellowBytes OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the counted number of forwarded bytes
that where marked Yellow."
::= { serviceStatEntry 12 }
srvForwardYellowBytesOverflow OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the number of times that the
forwardYellowBytes counter has overflowed."
::= { serviceStatEntry 13 }
srvDiscardGreenBytes OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the counted number of discarded bytes
that where marked Green."
::= { serviceStatEntry 14 }
srvDiscardGreenBytesOverflow OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the number of times that the
discardGreenBytes counter has overflowed."
::= { serviceStatEntry 15}
srvDiscardYellowRedBytes OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the counted number of discarded bytes
that where marked Yellow or Red."
::= { serviceStatEntry 16 }
srvDiscardYellowRedBytesOverflow OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the number of times that the
discardYellowRedBytes counter has overflowed."
::= { serviceStatEntry 17 }
srvResetStatsCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Reset statistic counters of the service."
::= { serviceStatEntry 18 }
srvDiscardYellowPackets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the counted number of discarded packets
that where marked Yellow."
::= { serviceStatEntry 19 }
srvDiscardYellowPacketsOverflow OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the number of times that the
discardYellowPackets counter has overflowed."
::= { serviceStatEntry 20 }
srvDiscardYellowBytes OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the counted number of discarded bytes
that where marked Yellow."
::= { serviceStatEntry 21 }
srvDiscardYellowBytesOverflow OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the number of times that the
discardYellowBytes counter has overflowed."
::= { serviceStatEntry 22 }
srvDiscardRedPackets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the counted number of discarded packets
that where marked Red."
::= { serviceStatEntry 23 }
srvDiscardRedPacketsOverflow OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the number of times that the
discardRedPackets counter has overflowed."
::= { serviceStatEntry 24 }
srvDiscardRedBytes OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the counted number of discarded bytes
that where marked Red."
::= { serviceStatEntry 25 }
srvDiscardRedBytesOverflow OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute displays the number of times that the
discardRedBytes counter has overflowed."
::= { serviceStatEntry 26 }
-- QoS Flow Mapping Definition
mappingProfileObjects OBJECT IDENTIFIER ::= { services 9 }
-- QoS Flow Mapping Profile table
flowMappingProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF FlowMappingProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table holds flow mapping profiles."
::= { mappingProfileObjects 1 }
flowMappingProfileEntry OBJECT-TYPE
SYNTAX FlowMappingProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in this table describes one Flow mapping profile with
one of its Flow Mapping supported, according to the Priority order.
The information includes a reference to a Flow Mapping index.
"
INDEX { flowMappingProfileIndex, flowMappingProfilePriority }
::= { flowMappingProfileTable 1 }
FlowMappingProfileEntry ::= SEQUENCE {
flowMappingProfileIndex Unsigned32,
flowMappingProfilePriority INTEGER,
flowMappingProfileRowStatus RowStatus,
flowMappingProfileNumOfMaps Unsigned32,
flowMappingProfileMapIndex Unsigned32,
flowMappingProfileName SnmpAdminString
}
flowMappingProfileIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A running index for the Flow Mapping Profile table."
::= { flowMappingProfileEntry 1 }
flowMappingProfilePriority OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The priority of the Mapping selected by flowMappingProfileMapIndex
within the Flow Mapping Profile."
::= { flowMappingProfileEntry 2 }
flowMappingProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute is used to create a new row or to delete an existing row
in the table."
::= { flowMappingProfileEntry 3 }
flowMappingProfileNumOfMaps OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the number of the mappings
associated to the Flow Mapping Profile."
::= { flowMappingProfileEntry 4 }
flowMappingProfileMapIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute holds a reference to the mapping index.
It specifies the mapping selected for the Mapping Profile
for the selected Priority.
When flowMappingProfileNumOfMaps=0, this attribute is not relevant."
::= { flowMappingProfileEntry 5 }
flowMappingProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute defines the name assigned to flowMappingIndex profile."
::= { flowMappingProfileEntry 6 }
-- QoS: Flow Mapping table
qosFlowMappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF QosFlowMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Flow Mapping."
::= { mappingProfileObjects 2 }
qosFlowMappingEntry OBJECT-TYPE
SYNTAX QosFlowMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in this table describes one Flow Mapping.
The information includes combination (AND function) of all the
classifications, as defined in the qosFlowMappingCriteria field.
Classifiers are: TOS, DSCP, VLAN ID, MAC and IP source and destination addresses,
IP protocol, IP Precedence, TCP and UDP source and destination ports."
INDEX { qosFlowMappingIdx1, qosFlowMappingIdx2, qosFlowMappingIdx3 }
::= { qosFlowMappingTable 1 }
QosFlowMappingEntry ::= SEQUENCE {
qosFlowMappingIdx1 Unsigned32,
qosFlowMappingIdx2 Unsigned32,
qosFlowMappingIdx3 Unsigned32,
qosFlowMappingRowStatus RowStatus,
qosFlowMappingCriteria BITS,
qosFlowMappingIeee802dot1p Unsigned32,
qosFlowMappingTos Unsigned32,
qosFlowMappingFromDscp Unsigned32,
qosFlowMappingToDscp Unsigned32,
qosFlowMappingFromVlanId Unsigned32,
qosFlowMappingToVlanId Unsigned32,
qosFlowMappingFromSrcMacAddr MacAddress,
qosFlowMappingToSrcMacAddr MacAddress,
qosFlowMappingFromDestMacAddr MacAddress,
qosFlowMappingToDestMacAddr MacAddress,
qosFlowMappingFromSrcIpAddr IpAddress,
qosFlowMappingToSrcIpAddr IpAddress,
qosFlowMappingFromDestIpAddr IpAddress,
qosFlowMappingToDestIpAddr IpAddress,
qosFlowMappingFromTcpSrcPort Unsigned32,
qosFlowMappingToTcpSrcPort Unsigned32,
qosFlowMappingFromTcpDestPort Unsigned32,
qosFlowMappingToTcpDestPort Unsigned32,
qosFlowMappingFromUdpSrcPort Unsigned32,
qosFlowMappingToUdpSrcPort Unsigned32,
qosFlowMappingFromUdpDestPort Unsigned32,
qosFlowMappingToUdpDestPort Unsigned32,
qosFlowMappingFromIpPrecedence Unsigned32,
qosFlowMappingToIpPrecedence Unsigned32,
qosFlowMappingInnerIeee802dot1p Unsigned32,
qosFlowMappingFromInnerVlanId Unsigned32,
qosFlowMappingToInnerVlanId Unsigned32,
qosFlowMappingEtherType Unsigned32
}
qosFlowMappingIdx1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
- In case the table is accessed via flowMappingProfileTable
this is a running index for the QoS Flow Mapping table.
- In case the table is not accessed via flowMappingProfileTable,
this will be the ifIndex of the XNI (bridge port) to which the
QoS mapping applies.
"
::= { qosFlowMappingEntry 1 }
qosFlowMappingIdx2 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index for the QoS Flow Mapping table.
- In case the table is accessed via flowMappingProfileTable
the index will be fixed = 1.
- In case the table is not accessed via flowMappingProfileTable,
this will be the index of the Flow (EVC) to which the QoS mapping applies.
"
::= { qosFlowMappingEntry 2 }
qosFlowMappingIdx3 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index for the QoS Flow Mapping table.
- In case the table is accessed via flowMappingProfileTable
the index will be fixed = 1.
- In case the table is not accessed via flowMappingProfileTable,
this will be the Priority to which the QoS mapping applies.
"
::= { qosFlowMappingEntry 3 }
qosFlowMappingRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute is used to create a new row or to delete an existing row
in the table."
::= { qosFlowMappingEntry 4 }
qosFlowMappingCriteria OBJECT-TYPE
SYNTAX BITS {
ieee802dot1p (0),
tos (1),
dscp (2),
vlanId (3),
macSrcAddr (4),
macDestAddr (5),
ipSrcAddr (6),
ipDestAddr (7),
tcpSrcPort (8),
tcpDestPort (9),
udpSrcPort (10),
udpDestPort (11),
ipPrecedence (12),
innerIeee802dot1p (13),
innerVlanId (14),
untagged (15),
nonIP (16),
etherType (17)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines upon which criterion the flow
will be mapped."
::= { qosFlowMappingEntry 5 }
qosFlowMappingIeee802dot1p OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines which TOS values are applicable for that flow.
Each bit (0..7) represents a different 802.1 P-bit value.
Setting '1' to the bit means that the corresponding 802.1 P-bit value is applicable.
It is relevant only in case the ieee802dot1p bit(0) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 6 }
qosFlowMappingTos OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines which TOS values are applicable for that flow.
Each bit (0..7) represents a different TOS value.
Setting '1' to the bit means that the corresponding TOS value is applicable.
It is relevant only in case the tos bit (1) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 7 }
qosFlowMappingFromDscp OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the first DSCP value to compare with in a range.
It is relevant only in case the dscp bit (2) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 8 }
qosFlowMappingToDscp OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the first DSCP value to compare with in a range.
It is relevant only in case the dscp bit (2) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 9 }
qosFlowMappingFromVlanId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the first VLAN ID value to compare with in a range.
It is relevant only in case the vlanId bit (3) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 10 }
qosFlowMappingToVlanId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the last VLAN ID value to compare with in a range.
It is relevant only in case the vlanId bit (3) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 11 }
qosFlowMappingFromSrcMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the first source MAC address to compare with in a range.
It is relevant only in case the macSrcAddr bit (4) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 12 }
qosFlowMappingToSrcMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the last source MAC address to compare with in a range.
It is relevant only in case the macSrcAddr bit (4) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 13 }
qosFlowMappingFromDestMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the first destination MAC address to compare with in a range.
It is relevant only in case the macDestAddr (5) bit in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 14 }
qosFlowMappingToDestMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the last destination MAC address to compare with in a range.
It is relevant only in case the macDestAddr (5) bit in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 15 }
qosFlowMappingFromSrcIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the first source IP address to compare with in a range.
It is relevant only in case the ipSrcAddr (6) bit in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 16 }
qosFlowMappingToSrcIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the last source IP address to compare with in a range.
It is relevant only in case the ipSrcAddr (6) bit in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 17 }
qosFlowMappingFromDestIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the first destination IP address to compare with in a range.
It is relevant only in case the ipDestAddr (7) bit in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 18 }
qosFlowMappingToDestIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the last destination IP address to compare with in a range.
It is relevant only in case the ipDestAddr (7) bit in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 19 }
qosFlowMappingFromTcpSrcPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the first TCP source port to compare with in a range.
It is relevant only in case the tcpSrcPort bit (8) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 20 }
qosFlowMappingToTcpSrcPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the last TCP source port to compare with in a range.
It is relevant only in case the tcpSrcPort bit (8) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 21 }
qosFlowMappingFromTcpDestPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the first TCP destination port to compare with in a range.
It is relevant only in case the tcpDestPort bit (9) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 22 }
qosFlowMappingToTcpDestPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the last TCP destination port to compare with in a range.
It is relevant only in case the tcpDestPort bit (9) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 23 }
qosFlowMappingFromUdpSrcPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the first UDP source port to compare with in a range.
It is relevant only in case the udpSrcPort bit (10) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 24 }
qosFlowMappingToUdpSrcPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the last UDP source port to compare with in a range.
It is relevant only in case the udpSrcPort bit (10) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 25 }
qosFlowMappingFromUdpDestPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the first UDP destination port to compare with in a range.
It is relevant only in case the udpDestPort bit (11) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 26 }
qosFlowMappingToUdpDestPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the last UDP destination port to compare with in a range.
It is relevant only in case the udpDestPort bit (11) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 27 }
qosFlowMappingFromIpPrecedence OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the first IpPrecedence value to compare with in a range.
It is relevant only in case the IpPrecedence bit (12) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 28 }
qosFlowMappingToIpPrecedence OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the last IpPrecedence value to compare with in a range.
It is relevant only in case the IpPrecedence bit (12) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 29 }
qosFlowMappingInnerIeee802dot1p OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines which TOS values are applicable for that flow.
Each bit (0..7) represents a different inner 802.1 P-bit value.
Setting '1' to the bit means that the corresponding inner 802.1 P-bit value is applicable.
It is relevant only in case the innerIeee802dot1p bit (13) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 30 }
qosFlowMappingFromInnerVlanId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the first inner VLAN ID value to compare with in a range.
It is relevant only in case the innerVlanId bit(14) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 31 }
qosFlowMappingToInnerVlanId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the last inner VLAN ID value to compare with in a range.
It is relevant only in case the innerVlanId bit(14) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 32 }
qosFlowMappingEtherType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Determines the Tag Protocol Identifier (in Hex).
For example:
0x8100 (C-TAG)
0x88A8 (S-TAG)
It is relevant only in case the etherType bit (17) in qosFlowMappingCriteria equals 1."
::= { qosFlowMappingEntry 33 }
-- CoS Profile Definition
cosProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF CosProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Class of Service Profile table.
Each profile holds a priority method, and a mappring function
that maps the priority values (range according to the method)
into CoS values."
::= { services 10 }
cosProfileEntry OBJECT-TYPE
SYNTAX CosProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row where each row contains one CoS attributes."
INDEX { cosProfileIndex }
::= { cosProfileTable 1 }
CosProfileEntry ::= SEQUENCE {
cosProfileIndex Unsigned32,
cosProfileRowStatus RowStatus,
cosProfileCosMethod INTEGER,
cosProfileName SnmpAdminString,
cosProfileCosMapping OCTET STRING
}
cosProfileIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the CoS Profile ID."
::= { cosProfileEntry 1 }
cosProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute is used to create a new row or to delete an existing row
in the table."
::= { cosProfileEntry 2 }
cosProfileCosMethod OBJECT-TYPE
SYNTAX INTEGER
{
ieee802dot1p (2),
tos (3),
dscp (4),
ipPrecedence (5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Defines the priority method upon CoS mapping is done."
::= { cosProfileEntry 3 }
cosProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute defines the name assigned to CoS profile."
::= { cosProfileEntry 4 }
cosProfileCosMapping OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute defines the value of the CoS that is assigned
for each priority. The number of the valid octets depends upon
the priority method selected:
Octet 0 corresponds to priority = 0
Octet 1 corresponds to priority = 1
...
Octet 63 corresponds to priority = 63.
"
::= { cosProfileEntry 5 }
-- Queue Profile Attributes
queueProfileObjects OBJECT IDENTIFIER ::= { services 11 }
qProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF QProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines the profiles for a cluster of queues.
"
::= { queueProfileObjects 1 }
qProfileEntry OBJECT-TYPE
SYNTAX QProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row where each row contains one Queue Cluster attribute. "
INDEX { qProfileIndex }
::= { qProfileTable 1 }
QProfileEntry ::= SEQUENCE {
qProfileIndex Unsigned32,
qProfileRowStatus RowStatus,
qProfileName SnmpAdminString,
qProfileNumberOfInternalQ Unsigned32,
qProfileInternalQProfile OCTET STRING
}
qProfileIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the Queue Cluster Profile ID."
::= { qProfileEntry 1 }
qProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute is used to create a new row or to delete an existing row
in the table."
::= { qProfileEntry 2 }
qProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute holds the name of the Queue cluster profile."
::= { qProfileEntry 3 }
qProfileNumberOfInternalQ OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute holds the number of the internal queue profiles
that are pointed by qInternalQProfile."
::= { qProfileEntry 4 }
qProfileInternalQProfile OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute holds the indexes to the queue profiles
in the qInternalProfileTable.
Each couple of octets holds an index to the qInternalProfileTable."
::= { qProfileEntry 5 }
qInternalProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF QInternalProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table holds queue profiles."
::= { queueProfileObjects 2 }
qInternalProfileEntry OBJECT-TYPE
SYNTAX QInternalProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row where each row contains one Queue attribute. "
INDEX { qInternalProfileIndex }
::= { qInternalProfileTable 1 }
QInternalProfileEntry ::= SEQUENCE {
qInternalProfileIndex Unsigned32,
qInternalProfileRowStatus RowStatus,
qInternalProfileScheduling INTEGER,
qInternalProfileWFQWeight Unsigned32,
qInternalProfileQueueLength Unsigned32,
qInternalProfileWredStartDropThresh Unsigned32,
qInternalProfileWredDropAllThresh Unsigned32,
qInternalProfileWredDropProbability Unsigned32,
qInternalProfileRateLimit Unsigned32,
qInternalProfileShaperProfile Unsigned32
}
qInternalProfileIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the Queue Profile ID."
::= { qInternalProfileEntry 1 }
qInternalProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute is used to create a new row or to delete an existing row
in the table."
::= { qInternalProfileEntry 2 }
qInternalProfileScheduling OBJECT-TYPE
SYNTAX INTEGER
{
wfq (1),
strict (2),
bestEffort (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the queue scheduling method."
::= { qInternalProfileEntry 3 }
qInternalProfileWFQWeight OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the weight that each WFQ (Weighted Fair Queue)
participant gets.
It is applicable only when scheduling is configured to WFQ."
::= { qInternalProfileEntry 4 }
qInternalProfileQueueLength OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the length of the queue."
::= { qInternalProfileEntry 5 }
qInternalProfileWredStartDropThresh OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the length that the queue (Start Value)
must reach before the packets colored yellow will start being dropped
by the WRED (Weighted Random Early Detection/Discard) mechanism.
WRED is one the most commonly used method for congestion avoidance."
::= { qInternalProfileEntry 6 }
qInternalProfileWredDropAllThresh OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the length that the queue (Stop Value)
must reach before the WRED (Weighted Random Early Detection)
shaper mechanism stops dropping randomly,
and just drops all further packets marked as yellow."
::= { qInternalProfileEntry 7 }
qInternalProfileWredDropProbability OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the percentage of packets that are being dropped
at the point when the length of the queue reaches the Stop value.
So, effectively, this defines how quickly the rate of dropping packet must
increase as the queue length grows from the Start Value to the Stop Value."
::= { qInternalProfileEntry 8 }
qInternalProfileRateLimit OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute determines the Rate Limit of the queue in Kbps.
Value=0 represents best effort."
::= { qInternalProfileEntry 9 }
qInternalProfileShaperProfile OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute defines the Shaper Profile (bwProfileIndex from bwProfileTable)
assigned to this qInternalProfile. Valid range of bwProfileIndex for Shaper
Profiles is 0x8000001-0x8000041.
If set to '0', no profile is assigned to this qInternalProfile."
::= { qInternalProfileEntry 10 }
queueGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF QueueGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines the queue groups/blocks,their level and connections between them."
::= { queueProfileObjects 3 }
queueGroupEntry OBJECT-TYPE
SYNTAX QueueGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row where each row contains one Queue group. "
INDEX {queueGroupName, queueGroupQBlockLevel,queueGroupQBlockIdx}
::= { queueGroupTable 1 }
QueueGroupEntry ::= SEQUENCE {
queueGroupName SnmpAdminString,
queueGroupQBlockLevel Unsigned32,
queueGroupQBlockIdx Unsigned32,
queueGroupRowStatus RowStatus,
queueGroupQBlockProfile Unsigned32,
queueGroupQBlockShaperProfile Unsigned32,
queueGroupPointToQBlock SnmpAdminString,
queueGroupPointToInternalQueue Unsigned32 ,
queueGroupQBlockName SnmpAdminString
}
queueGroupName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (1..32))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the Queue Group unique name."
::= { queueGroupEntry 1 }
queueGroupQBlockLevel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This attribute holds the Level of the Queue Block .First level is 1.
NA=2^32-1."
::= { queueGroupEntry 2 }
queueGroupQBlockIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This attribute holds the ID of the Queue Block.
NA=2^32-1."
::= { queueGroupEntry 3 }
queueGroupRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute is used to create a new row or to delete an existing row
in the table."
::= { queueGroupEntry 4 }
queueGroupQBlockProfile OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute defines the Queue profile assigned to this Queue Block.
This object points to qProfileIndex in qProfileTable. "
::= { queueGroupEntry 5 }
queueGroupQBlockShaperProfile OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute defines the Shaper profile assigned to this Queue Block."
::= { queueGroupEntry 6 }
queueGroupPointToQBlock OBJECT-TYPE
SYNTAX SnmpAdminString(SIZE (1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute defines the Queue Block name of the next Queue Block level
that is pointed by this Queue Block."
::= { queueGroupEntry 7 }
queueGroupPointToInternalQueue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute defines the internal queue whithin queueGroupPointToQBlock
that is pointed by this Queue Block."
::= { queueGroupEntry 8 }
queueGroupQBlockName OBJECT-TYPE
SYNTAX SnmpAdminString(SIZE (1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute holds the name of the Queue Block."
::= { queueGroupEntry 9 }
-- Marking Profile Attributes
markingProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF MarkingProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Marking profile table. Each profile holds a marking function
which converts CoS values to Service Provider priority values."
::= { services 12 }
markingProfileEntry OBJECT-TYPE
SYNTAX MarkingProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row where each row contains one Marking attribute. "
INDEX { markingProfileIndex }
::= { markingProfileTable 1 }
MarkingProfileEntry ::= SEQUENCE {
markingProfileIndex Unsigned32,
markingProfileRowStatus RowStatus,
markingProfileName SnmpAdminString,
markingSpVlanPBit OCTET STRING,
markingProfileMethod INTEGER
}
markingProfileIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the Marking Profile ID."
::= { markingProfileEntry 1 }
markingProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute is used to create a new row or to delete an existing row
in the table."
::= { markingProfileEntry 2 }
markingProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute defines the unique name assigned to the Marking profile."
::= { markingProfileEntry 3 }
markingSpVlanPBit OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..63))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"For ETX-202A :
This attribute defines the value of the SP VLAN P-Bit that is assigned
for each CoS:
Octet 0 corresponds to CoS = 0
Octet 1 corresponds to CoS = 1
...
Octet 7 corresponds to CoS = 7.
For LA-210 from V1.5 :
This attribute defines the value of the SP VLAN P-Bit that is assigned
for each frame according to the value of markingProfileMethod parameter :
Octet 0 corresponds to value 0 of 802.1 P-bit/DSCP/TOS.
Octet 1 corresponds to value 1 of 802.1 P-bit/DSCP/TOS.
...
Octet 7 corresponds to value 7 of 802.1 P-bit/DSCP/TOS.
Octets 8-63 correspond to DSCP values 8-63.
"
::= { markingProfileEntry 4 }
markingProfileMethod OBJECT-TYPE
SYNTAX INTEGER
{
ieee802dot1p (2),
tos (3),
dscp (4),
ipPrecedence (5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute defines the method upon which marking is done."
::= { markingProfileEntry 5 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\atmRoute.txt
--
--Version: 4.95
--
--First Version Date: 12-Aug-2002
--By: Shay Harari
--File: atmRouter.txt
--
--Last update: 20-Oct-2002
--By: Ilana Schvetz
radAtmRouter OBJECT IDENTIFIER ::= { radAtm 10 }
-- Extension of the ATM Logical IP Subnet Interface Mapping Table
-- ( ipoaLisIfMappingTable from RFC 2320 )
atmIpoaLisIfMappingXTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIpoaLisIfMappingXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of a table
from RFC 2320: ipoaLisIfMappingTable -
The ATM Logical IP Subnet Interface Mapping Table."
::= { radAtmRouter 1 }
atmIpoaLisIfMappingXEntry OBJECT-TYPE
SYNTAX AtmIpoaLisIfMappingXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Conceptual row in ipoaLisIfMappingTable."
AUGMENTS { ipoaLisIfMappingEntry }
::= { atmIpoaLisIfMappingXTable 1 }
AtmIpoaLisIfMappingXEntry ::= SEQUENCE {
atmIpoaLisIfMappingType
INTEGER,
atmIpoaLisIfMappingIPAddress
IpAddress
}
atmIpoaLisIfMappingType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
static(2),
inAtmArp(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the Mapping Type."
::= { atmIpoaLisIfMappingXEntry 1 }
atmIpoaLisIfMappingIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter is applicable for
atmIpoaLisIfMappingTypeIP=static(2).
This parameter is the IP Address assigned
by the user when applicable."
::= { atmIpoaLisIfMappingXEntry 2 }
radAtmRtrInAtmArpInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time interval (in seconds) between sending of
two InATMARP requests."
::= { radAtmRouter 2 }
radAtmRtrInAtmArpAgingTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time (in seconds) that passes until an
entry is deleted, unless this entry
was previously updated by a new inATMARP
request or response.
This variable value should be greater than
the value of radAtmRtrInAtmArpInterval,
so that the entry won't be deleted before
an InATMARP request was sent."
::= { radAtmRouter 3 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\voiceIf.txt
--
--Version:
--Date: 25/02/2003
--By: Yig'al Hachmon
--V:\doc\rdv\mib\ver495\voiceIf.txt
--Last changed by Liora Gafni, 17 Aug 2004
--diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6 }
voiceIf OBJECT IDENTIFIER ::= {diverseIfWanGen 13}
-- Voice Interface Ringing Cadence Configuration table
voiceIfCadenceCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoiceIfCadenceCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Voice port ringing cadence configuration table.
Each ringing cycle, indexed by voiceIfCadenceIdx,
consists of a number of ring ON-Period/ring OFF-Period
pairs. Pairs are indexed sequentially, according to
voiceIfCadencePeriodIdx: 1,2,...number of pairs"
::= { voiceIf 1 }
voiceIfCadenceCnfgEntry OBJECT-TYPE
SYNTAX VoiceIfCadenceCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ringing cadence configuration per voice port."
INDEX {voiceIfCadenceCnfgIdx,
voiceIfCadencePortIdx,
voiceIfCadenceIdx,
voiceIfCadencePeriodIdx}
::= {voiceIfCadenceCnfgTable 1}
VoiceIfCadenceCnfgEntry ::=
SEQUENCE {
voiceIfCadenceCnfgIdx Integer32,
voiceIfCadencePortIdx Integer32,
voiceIfCadenceIdx Integer32,
voiceIfCadencePeriodIdx Integer32,
voiceIfCadenceRowStatus RowStatus,
voiceIfCadenceRingOnPeriod Integer32,
voiceIfCadenceRingOffPeriod Integer32
}
voiceIfCadenceCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Idx of the
Agent Cnfg the following objects refer to.
255=Temporary Cnfg (when relevant,
Set is done only to this configuration).
For Agents that support only one configuration,
this object will be constant=1. "
::= {voiceIfCadenceCnfgEntry 1}
voiceIfCadencePortIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Voice Port Index. May equal to the value of ifIndex."
::= {voiceIfCadenceCnfgEntry 2}
voiceIfCadenceIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cadence (ringing type) index."
::= {voiceIfCadenceCnfgEntry 3}
voiceIfCadencePeriodIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Periods index (pair number) in a ringing cycle Cadence.
This index must be sequential, start from 1. Its maximum
value is the number of pairs of certain ringing type.
For Vmux-110, one or two period pairs may be defined."
::= { voiceIfCadenceCnfgEntry 4}
voiceIfCadenceRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute allows to create/delete
ringing cadence entry in this table.
For Vmux-110, only a single cadance can be defined.
Delete action of a period entry can be performed only
if it is the last existing period of the cadance."
::= {voiceIfCadenceCnfgEntry 5 }
voiceIfCadenceRingOnPeriod OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Duration (in tenth of seconds) of Ringing (ON)
period."
::= { voiceIfCadenceCnfgEntry 6}
voiceIfCadenceRingOffPeriod OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Duration (in tenth of seconds) of Silence (OFF)
period."
::= { voiceIfCadenceCnfgEntry 7}
-- Voice Interface Configuration & Status table
voiceIfCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoiceIfCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Voice port configuration table."
::= { voiceIf 2 }
voiceIfCnfgEntry OBJECT-TYPE
SYNTAX VoiceIfCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration per voice port."
INDEX {voiceIfCnfgIdx,voiceIfPortIdx}
::= { voiceIfCnfgTable 1 }
VoiceIfCnfgEntry ::=
SEQUENCE {
voiceIfCnfgIdx Integer32,
voiceIfPortIdx Integer32,
voiceIfRingingTimeout Integer32,
voiceIfFlashTimeout Integer32,
voiceIfRxGain Integer32,
voiceIfTxGain Integer32,
voiceIfSignalingABCD OCTET STRING,
voiceIfState INTEGER,
voiceIfCallState INTEGER
}
voiceIfCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Idx of the
Agent Cnfg the following objects refer to.
255=Temporary Cnfg (when relevant,
Set is done only to this configuration).
For Agents that support only one configuration,
this object will be constant=1. "
::= { voiceIfCnfgEntry 1}
voiceIfPortIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of voice port ."
::= {voiceIfCnfgEntry 2}
voiceIfRingingTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ringing timeout in seconds."
::= {voiceIfCnfgEntry 3}
voiceIfFlashTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A time period in milliseconds. Flash (Register Recall)
is detected if On-Hook time is shorter than this timeout."
::= {voiceIfCnfgEntry 4}
voiceIfRxGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Receive gain in dB."
::= {voiceIfCnfgEntry 5}
voiceIfTxGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transmission gain in dB."
::= {voiceIfCnfgEntry 6}
voiceIfSignalingABCD OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Octet String.
Nibble No. 1 represents ON Hook (same for Rx and Tx).
Nibble No. 2 represents OFF Hook (same for Rx and Tx).
Nibble No. 3 represents Reverse Polarity.
Nibble No. 4 represents Ring pattern 1.
Nibble No. 5 represents Ring pattern 2.
Nibble No. 6 is not used.
The bits will be as following:
Bit 1 = Bit A - ON Hook (LSB)
Bit 2 = Bit B - ON Hook
Bit 3 = Bit C - ON Hook
Bit 4 = Bit D - ON Hook
Bit 5 = Bit A - OFF Hook
Bit 6 = Bit B - OFF Hook
Bit 7 = Bit C - OFF Hook
Bit 8 = Bit D - OFF Hook
Bit 9 = Bit A - Reverse Polarity
Bit 10 = Bit B - Reverse Polarity
Bit 11 = Bit C - Reverse Polarity
Bit 12 = Bit D - Reverse Polarity
Bit 13 = Bit A - Ring 1
Bit 14 = Bit B - Ring 1
Bit 15 = Bit C - Ring 1
Bit 16 = Bit D - Ring 1
Bit 17 = Bit A - Ring 2
Bit 18 = Bit B - Ring 2
Bit 19 = Bit C - Ring 2
Bit 20 = Bit D - Ring 2
Bits 21...24 = 0 (not used). (Bit 24 is MSB).
For Vmux-110:
Ring 1 and Ring 2 are used. The default is 3 octets.
(MSB) 0000 1011 1011 1001 1011 1010 (LSB)"
::= {voiceIfCnfgEntry 7}
voiceIfState OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
onHook (2), --ON Hook State = idle
offHook (3) -- OFF HOOK state
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Attribute indicating voice port state."
::= { voiceIfCnfgEntry 8}
voiceIfCallState OBJECT-TYPE
SYNTAX INTEGER {
noCall (1),
oos (2), -- out of service
dialing (3),
waitForAlert (4),
waitForConnect(5),
ringing (6),
active (7),
waitForReject (8),
waitForInfo (9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Attribute indicating the status of the call on this port.
In Vmux devices this attribute is used for FXS ports."
::= { voiceIfCnfgEntry 9}
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\radGsm.txt
--
-- RAD-GSM-MIB DEFINITIONS ::= BEGIN
--Title: RAD's GSM INTERFACE MIB
--Version: 5.30
--Date: 25.01.2006
--By: Shay Harari
--File: radGsm.txt
--
--Last update: 23-Dec-2007 by Shay Harari
gsmInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 14}
prtGsmConfig OBJECT IDENTIFIER ::= {gsmInterface 1}
-- GSM Interface Configuration Table
prtGsmConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtGsmConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"GSM Interface Configuration Table."
::= { prtGsmConfig 1}
prtGsmConfigEntry OBJECT-TYPE
SYNTAX PrtGsmConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the GSM Interface Configuration Table."
INDEX { prtGsmConfigIdx1, prtGsmConfigIdx2 }
::= { prtGsmConfigTable 1}
PrtGsmConfigEntry ::=
SEQUENCE {
prtGsmConfigIdx1 Unsigned32,
prtGsmConfigIdx2 Unsigned32,
prtGsmConfigIfType INTEGER,
prtGsmConfigUplinkTxDirection INTEGER,
prtGsmConfigSubChRate INTEGER,
prtGsmConfigClockTracking INTEGER,
prtGsmConfigTrauIdleFrame INTEGER,
prtGsmConfigDownlinkTrauSilenceFrame INTEGER,
prtGsmConfigGprsFrame INTEGER,
prtGsmConfigUnkTrauFrameSuppression INTEGER,
prtGsmConfigUnkTrauFrameOptimization INTEGER,
prtGsmConfigSilenceSuppressionRatio Unsigned32,
prtGsmConfigStatus INTEGER,
prtGsmConfigUpstreamOptimization BITS,
prtGsmConfigDownstreamOptimization BITS,
prtGsmConfigByteReversal INTEGER,
prtGsmConfigTxJitter Unsigned32,
prtGsmConfigSpdThreshold Unsigned32
}
prtGsmConfigIdx1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The first index of the table.
This object might represent the Configuration Index (1..100) being accessed,
where Index=255 relates to the TmpCnfg.
For devices with multiple configurations, Set is permitted to TmpCnfg(255) only.
Not-Applicable = 1."
::= { prtGsmConfigEntry 1}
prtGsmConfigIdx2 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The second index of the table.
This object might represent the port index
and for some devices might be the ifIndex.
For System level or when NA, value = 1."
::= { prtGsmConfigEntry 2}
prtGsmConfigIfType OBJECT-TYPE
SYNTAX INTEGER
{
abis (1),
ater (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The GSM Interface Type."
::= { prtGsmConfigEntry 3 }
prtGsmConfigUplinkTxDirection OBJECT-TYPE
SYNTAX INTEGER
{
upStream (1),
downStream (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Tx Direction toward the network."
::= { prtGsmConfigEntry 4 }
prtGsmConfigSubChRate OBJECT-TYPE
SYNTAX INTEGER
{
dynamic (1),
r8Kbps (2),
r16Kbps (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Sub Channel Rate."
::= { prtGsmConfigEntry 5 }
prtGsmConfigClockTracking OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Clock Tracking.
This object is relevant only when Egress Uplink is LAN and
the device (e.g. Vmux) on the BSC side is Rx Clock and
the device (e.g. Vmux) on the BTS side is Internal Clock.
On this configuration the Vmux-400 on the BTS side
will adjust its internal oscillator frequency according to
the information it gets from the Vmux-400 on the BSC side."
::= { prtGsmConfigEntry 6 }
prtGsmConfigTrauIdleFrame OBJECT-TYPE
SYNTAX INTEGER
{
idlePcm (1),
idleSpeech (2),
asymIdleSpeech (3) -- Asymmetric Idle Speech
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TRAU frame to be used between calls."
::= { prtGsmConfigEntry 7 }
prtGsmConfigDownlinkTrauSilenceFrame OBJECT-TYPE
SYNTAX INTEGER
{
sidFrame (1), -- Silence Insertion Description Frame
idleSpeech (2),
lastReceive (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TRAU frame to be used in the downlink direction
for silence/missing data."
::= { prtGsmConfigEntry 8 }
prtGsmConfigGprsFrame OBJECT-TYPE
SYNTAX INTEGER
{
other (1),
trau (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The GPRS Frame Type."
::= { prtGsmConfigEntry 9 }
prtGsmConfigUnkTrauFrameSuppression OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables/disables suppression of unknown TRAU frames."
::= { prtGsmConfigEntry 10 }
prtGsmConfigUnkTrauFrameOptimization OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables/disables optimization of unknown TRAU frames."
::= { prtGsmConfigEntry 11 }
prtGsmConfigSilenceSuppressionRatio OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Silence Suppression Ratio, measured in percentages (1%).
0 = No Suppression.
In case comfort noise is rapidly changed,
it may cause the silence to be heard like a dead line
instead of hearing the comfort noise.
This parameter enables improvement of comfort noise generation,
at the expense of less optimization.
In case an invalid value is set,
the Agent should accept such a request by setting it to the nearest LOWER valid value.
For example:
- Valid values are 0, 50, 90 and 98
- Attribute is set to 89
- Agent should set the attribute to 50
."
::= { prtGsmConfigEntry 12 }
prtGsmConfigStatus OBJECT-TYPE
SYNTAX INTEGER
{
active (1),
notInService (2),
notReady (3),
createAndGo (4),
createAndWait (5),
destroy (6),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables the user to create/delete entries in this table.
Its usage for values (1)..(6) should be identical to RowStatus SYNTAX.
notApplicable(255) - should be used when the table is static
(i.e. whenever create/delete entries is not allowed)."
::= { prtGsmConfigEntry 13 }
prtGsmConfigUpstreamOptimization OBJECT-TYPE
SYNTAX BITS
{
optimization (0),
compression (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the Optimization Mode
at the Upstream direction (BTS -> BSC)."
::= { prtGsmConfigEntry 14 }
prtGsmConfigDownstreamOptimization OBJECT-TYPE
SYNTAX BITS
{
optimization (0),
compression (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the Optimization Mode
at the Downstream direction (BSC -> BTS)."
::= { prtGsmConfigEntry 15 }
prtGsmConfigByteReversal OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines whether BTS/BSC reverses the bytes or not."
::= { prtGsmConfigEntry 16 }
prtGsmConfigTxJitter OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Transmit Jitter size (in msec), towards the BTS/BSC"
::= { prtGsmConfigEntry 17 }
prtGsmConfigSpdThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SPD (Smart Packet Drop) Threshold.
SPD mechanism decides which frames to drop
according to the voice energy of the frame.
A frame should be dropped in case its voice energy
is lower than the SPD Threshold."
::= { prtGsmConfigEntry 18 }
-- GSM Interface Traffic Table
prtGsmTrafficTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtGsmTrafficEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"GSM Interface Traffic Table."
::= { prtGsmConfig 2 }
prtGsmTrafficEntry OBJECT-TYPE
SYNTAX PrtGsmTrafficEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the GSM Interface Traffic Table."
INDEX { prtGsmTrafficIdx1, prtGsmTrafficIdx2, prtGsmTrafficType }
::= { prtGsmTrafficTable 1}
PrtGsmTrafficEntry ::=
SEQUENCE {
prtGsmTrafficIdx1 Unsigned32,
prtGsmTrafficIdx2 Unsigned32,
prtGsmTrafficType INTEGER,
prtGsmTrafficVpi Unsigned32,
prtGsmTrafficVci Unsigned32,
prtGsmTrafficMultiplexFrameSize Unsigned32,
prtGsmTrafficTxInterval Unsigned32
}
prtGsmTrafficIdx1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The first index of the table.
This object might represent the Configuration Index (1..100) being accessed,
where Index=255 relates to the TmpCnfg.
For devices with multiple configurations, Set is permitted to TmpCnfg(255) only.
Not-Applicable = 1."
::= { prtGsmTrafficEntry 1}
prtGsmTrafficIdx2 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The second index of the table.
This object might represent the port index
and for some devices might be the ifIndex.
For System level or when NA, value = 1."
::= { prtGsmTrafficEntry 2}
prtGsmTrafficType OBJECT-TYPE
SYNTAX INTEGER
{
signaling (1),
voice (2),
data (3)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The GSM Interface Traffic Type."
::= { prtGsmTrafficEntry 3 }
prtGsmTrafficVpi OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The VPI (of VPI/VCI pair) that should be used in connection
with this traffic type."
::= { prtGsmTrafficEntry 4 }
prtGsmTrafficVci OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The VCI (of VPI/VCI pair) that should be used in connection
with this traffic type."
::= { prtGsmTrafficEntry 5 }
prtGsmTrafficMultiplexFrameSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Multiplexed Frame Size (in bytes) of this traffic type."
::= { prtGsmTrafficEntry 6 }
prtGsmTrafficTxInterval OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Tx Interval (in msec) of this traffic type."
::= { prtGsmTrafficEntry 7 }
-- END
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\Pw.txt
--
-- RAD Pseudo Wire Text file
-- Version: 5.35
-- First Version Date: 16-May-2006
-- By: Yig'al Hachmon
-- File: pw.txt
-- Last update: 29-May-2008 by Yig'al Hachmon
radPwNotifications OBJECT IDENTIFIER ::= { radPw 0 }
radPwCfgObjects OBJECT IDENTIFIER ::= { radPw 1 }
radPwPerfMonitoring OBJECT IDENTIFIER ::= { radPw 2 }
radPwGenCfgObjects OBJECT IDENTIFIER ::= { radPwCfgObjects 1 }
radPwPsnCfgObjects OBJECT IDENTIFIER ::= { radPwCfgObjects 2 }
radPwServiceCfgObjects OBJECT IDENTIFIER ::= { radPwCfgObjects 3 }
-- *** PW General Parameters ***
pwGenTable OBJECT-TYPE
SYNTAX SEQUENCE OF PwGenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains general configuration for
PW connection."
::= { radPwGenCfgObjects 1 }
pwGenEntry OBJECT-TYPE
SYNTAX PwGenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is indexed by pwIdx, the value of which is equal
to the same index that was created for the associated entry
in the PW Table (in the PW-STD-MIB)- the pwIndex.
An entry is created in this table by the agent for every
entry in the pwTable."
INDEX { pwIdx }
::= { pwGenTable 1 }
PwGenEntry ::= SEQUENCE {
pwIdx Unsigned32,
pwGenPeerIdx Unsigned32,
pwGenAttachmentCircuit InterfaceIndexOrZero,
pwGenOutgoingInterface InterfaceIndexOrZero,
pwGenOamMode INTEGER,
pwGenOamType INTEGER,
pwGenSequenceNumberField INTEGER,
pwGenNextHopType INTEGER,
pwGenNextHop Unsigned32,
pwGenIpNextHop IpAddress,
pwGenMacNextHop MacAddress,
pwGenEnableVlanTag INTEGER,
pwGenVlanId Unsigned32,
pwGenVlanPriority Unsigned32,
pwGenIpTos Unsigned32,
pwGenSourceUdpPort Unsigned32,
pwGenSubType INTEGER,
pwGenSourceIpAddress IpAddress,
pwGenSourceIpMask IpAddress
}
pwIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of this table.
The value for this object is equal to the value
of pwIndex from the pwTable of PW-STD-MIB"
::= { pwGenEntry 1}
pwGenPeerIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Index of the Peer
(as it is defined in the Peer Table), which terminated this PW."
::= { pwGenEntry 2 }
pwGenAttachmentCircuit OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is a unique index within the ifTable. It represents
the attached circuit interface (e.g ATM VC, HDLC) attached to
this PW connection (from service initiator side).
A value of zero indicates an interface index that has yet
to be determined.
Once set, if the attached circuit is (for some reason) later
removed, the agent should DELETE the associated PW rows.
If the agent does not delete the rows,
the agent MUST set this object to zero.
This object is applicable only for device which
translates Attachment Circuit to other logical interface. "
::= { pwGenEntry 3 }
pwGenOutgoingInterface OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is a unique index within the ifTable. It represents
the outgoing interface (towards the PSN ) attached to
this PW connection.
This object is applicable only for MPLS peer, for device
without router, when Next Hop is not defined.
A value of zero indicates an interface index that has yet
to be determined, or it is not applicable.
Once set, if the outgoing interface is (for some reason) later
removed, the agent should DELETE the associated PW rows.
If the agent does not delete the rows,
the agent MUST set this object to zero.
This object is applicable only for devices that allow
manual configuration of outgoing interface."
::= { pwGenEntry 4 }
pwGenOamMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This objects defines whether OAM will be enabled on this PW.
notApplicable(1) value will be used when
PW type does not support OAM."
::= { pwGenEntry 5 }
pwGenOamType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
propietary (2),
bfd (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This objects defines the failure detection mechanism used
on this PW.
BFD - Bidirectional Forwarding Detection
notApplicable(1) value will be used when
pwGenOamMode is notApplicable."
::= { pwGenEntry 6 }
pwGenSequenceNumberField OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines whether processing of Sequence Number field
(ATM cell encapsulation) will be done by device, on this PW."
::= { pwGenEntry 7 }
pwGenNextHopType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
atmVc (2),
bridgePort (3),
ipV4 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates address type of the Next Hop.
Not applicable for device with router."
::= { pwGenEntry 8 }
pwGenNextHop OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Not applicable (=0) when pwMplsEgressTunnelNextHopType=notApplicable.
When applicable, represents ATM VC, Bridge Port,
according to pwMplsEgressTunnelNextHopType."
::= { pwGenEntry 9}
pwGenIpNextHop OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines local Next Hop IP Address for this PW.
0.0.0.0 - means - not applicable.
This object is applicable only when pwGenNextHopType=ipV4"
::= { pwGenEntry 10 }
pwGenMacNextHop OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines local Next Hop MAC Address for this PW.
0:0:0:0:0:0 - means - not applicable.
This object is applicable only when pwGenNextHopType=bridgePort"
::= { pwGenEntry 11 }
pwGenEnableVlanTag OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables or diables a VLAN tag on
every transmitted paket via this PW connection"
::= { pwGenEntry 12 }
pwGenVlanId OBJECT-TYPE
SYNTAX Unsigned32 (1..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the VLAN ID tag attached
to every transmitted packet via this PW connection.
This entry is applicable only if pwGenEnableVlanTag=enabled (3)."
::= { pwGenEntry 13 }
pwGenVlanPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the VLAN priority assigned
to every transmitted packet via this PW connection.
This entry is applicable only if pwGenEnableVlanTag=enabled (3)"
::= { pwGenEntry 14 }
pwGenIpTos OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates TOS field value
for pw having pwPsnType= ip (3)"
::= { pwGenEntry 15 }
pwGenSourceUdpPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates source UDP port (1...65535) value
for pw having pwPsnType= ip (3)"
::= { pwGenEntry 16 }
pwGenSubType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
clockRecovery (2),
clockDistribution (3),
data (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the PW Sub Type
(i.e. Sub Type of 'pwType' from 'pwTable').
For ACE-3000 devices:
It is applicable only when pwType = basicCesPsn(21)."
::= { pwGenEntry 17 }
pwGenSourceIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Source IP Address per PW"
::= { pwGenEntry 18 }
pwGenSourceIpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Source IP Mask per PW"
::= { pwGenEntry 19 }
pwGenTimeout OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Timeout period, measured in usec.
This object is relevant only for ATM service."
::= { radPwGenCfgObjects 2 }
pwGenMisorderWindowSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Window Size (in packets),
in which the device will attempt to reorder packets.
Packets having sequence number with gap greater than the Window Size -
will not take part in the process.
This object is relevant only for ATM service."
::= { radPwGenCfgObjects 3 }
pwGenFixMisorderSupport OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines whether the process of reorder,
within the Window Size (pwGenMisorderWindowSize), should be activated or not.
This object is relevant only for ATM service."
::= { radPwGenCfgObjects 4 }
pwGenLabelTable OBJECT-TYPE
SYNTAX SEQUENCE OF PwGenLabelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines supported range of PW labels."
::= { radPwGenCfgObjects 5 }
pwGenLabelEntry OBJECT-TYPE
SYNTAX PwGenLabelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in this table defines range of PW labels in the direction and type
indicated by pwGenLabelType and pwGenLabelDirection."
INDEX { pwGenLabelType,
pwGenLabelDirection}
::= { pwGenLabelTable 1 }
PwGenLabelEntry ::= SEQUENCE {
pwGenLabelType INTEGER,
pwGenLabelDirection INTEGER,
pwGenLabelMinValue Unsigned32,
pwGenLabelMaxValue Unsigned32
}
pwGenLabelType OBJECT-TYPE
SYNTAX INTEGER
{
static (2),
dynamic(3)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object defines type of label."
::= { pwGenLabelEntry 1 }
pwGenLabelDirection OBJECT-TYPE
SYNTAX INTEGER
{
ingress (2),
egress (3)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object defines PW direction."
::= { pwGenLabelEntry 2 }
pwGenLabelMinValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines minimum value of PW labels,
in the direction and type indicated by
pwGenLabelType and pwGenLabelDirection."
::= { pwGenLabelEntry 3 }
pwGenLabelMaxValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object define maximum value of PW labels,
in the direction and type indicated by
pwGenLabelType and pwGenLabelDirection."
::= { pwGenLabelEntry 4 }
-- Peer Table
peerTable OBJECT-TYPE
SYNTAX SEQUENCE OF PeerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Peer Table"
::= { radPwGenCfgObjects 6 }
peerEntry OBJECT-TYPE
SYNTAX PeerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table."
INDEX { peerIndex }
::= { peerTable 1 }
PeerEntry ::= SEQUENCE {
peerIndex Unsigned32,
peerRowStatus RowStatus,
peerAddressType InetAddressType,
peerAddress InetAddress,
peerName SnmpAdminString,
peerNoOfUsages Unsigned32,
peerTargeted INTEGER,
peerNextHopAddressType InetAddressType,
peerNextHopAddress InetAddress
}
peerIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the Peer Index."
::= { peerEntry 1 }
peerRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used for creating, modifying and deleting
a row of this table."
::= { peerEntry 2 }
peerAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the Address Type of the Peer node.
It should be set to 'unknown' if PE/PW maintenance protocol
is not used and the address is unknown."
::= { peerEntry 3 }
peerAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the Peer node Address.
of the PW/PE maintenance protocol entity.
This object SHOULD contain a value of all zeroes if not applicable
(peerAddrType is 'unknown')."
::= { peerEntry 4 }
peerName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the Peer Name."
::= { peerEntry 5 }
peerNoOfUsages OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of times this Peer is used
(by PWs, Egress LSP Tunnels etc)."
::= { peerEntry 6 }
peerTargeted OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates whether the Peer is configured
as a Targeted Peer or not."
::= { peerEntry 7 }
peerNextHopAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the Address Type of the Peer Next Hop node.
It should be set to 'unknown' if the address is unknown."
::= { peerEntry 8 }
peerNextHopAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the Peer Next Hop node Address.
This object SHOULD contain a value of all zeroes if not applicable
(peerAddrType is 'unknown')."
::= { peerEntry 9 }
-- *** PW PSN Parameters
-- *** MPLS PSN type parameters ***
radPwPsnCfgMpls OBJECT IDENTIFIER ::= { radPwPsnCfgObjects 1}
-- MPLS Type PSN Configuration Table
pwMplsCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PwMplsCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains MPLS PSN related configuration for
PW connection."
::= { radPwPsnCfgMpls 1 }
pwMplsCfgEntry OBJECT-TYPE
SYNTAX PwMplsCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is indexed by pwIdx, the value of which is equal
to the same index that was created for the associated entry
in the PW Table (in the PW-STD-MIB)- the pwIndex.
An entry is created in this table by the agent for every
entry in the pwGenTable with a pwGenPsnType=MPLS."
INDEX { pwIdx }
::= { pwMplsCfgTable 1 }
PwMplsCfgEntry ::= SEQUENCE {
pwMplsCfgIngressTunnel Unsigned32,
pwMplsCfgEgressTunnel Unsigned32
}
pwMplsCfgIngressTunnel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object points to an entry of pwMplsIngressTunnelTable.
Its value is equal to pwMplsIngressTunnelIndex"
::= { pwMplsCfgEntry 1}
pwMplsCfgEgressTunnel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object points to an entry of pwMplsEgressTunnelTable.
Its value is equal to pwMplsEgressTunnelIndex."
::= { pwMplsCfgEntry 2 }
-- *** ETH PSN Type tables were removed
-- since there's no ETH PSN.
-- VLAN parameters were replaced by
-- pwGenEnableVlanTag, pwGenVlanId,pwGenVlanPriority
-- *** IP PSN Type tables were removed.
-- *** Service Parameters ***
-- *** TDM over IP / CESoPSN Service
radPwServiceCfgTDMoIp OBJECT IDENTIFIER ::= { radPwServiceCfgObjects 1}
pwTDMoIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF PwTDMoIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains TDMoIP Service related configuration for
PW connection."
::= { radPwServiceCfgTDMoIp 1 }
pwTDMoIpEntry OBJECT-TYPE
SYNTAX PwTDMoIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is indexed by pwIdx, the value of which is equal
to the same index that was created for the associated entry
in the PW Table (in the PW-STD-MIB)- the pwIndex.
An entry is created in this table by the agent for every
entry in the pwTable with a pwType equal to one of the
following:
e1Satop(17), t1Satop(18), e3Satop(19), t3Satop(20),
basicCesPsn(21), basicTdmIp(22), tdmCasCesPsn(23),
tdmCasTdmIp(24)."
INDEX { pwIdx }
::= { pwTDMoIpTable 1 }
PwTDMoIpEntry ::= SEQUENCE {
pwTDMoIpCfgIndex Unsigned32
}
pwTDMoIpCfgIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Index to TDMoIP table below. Multiple TDMoIP PWs
MAY share a single pwTDMoIpCfgEntry"
::= { pwTDMoIpEntry 1}
-- *** TDM over IP / CESoPSN Service configuration table
pwTDMoIpIndexNext OBJECT-TYPE
SYNTAX IndexIntegerNextFree
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an unused value for
pwTDMoIpCfgTableIndex, or a zero to indicate
that none exist. Negative values are not allowed,
as they do not correspond to valid values of
pwTDMoIpCfgTableIndex."
::= { radPwServiceCfgTDMoIp 2 }
pwTDMoIpCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PwTDMoIpCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains TDM over IP service configuration
for PW connection."
::= { radPwServiceCfgTDMoIp 3 }
pwTDMoIpCfgEntry OBJECT-TYPE
SYNTAX PwTDMoIpCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is indexed by pwIdx, the value of which is equal
to the same index that was created for the associated entry
in the PW Table (in the PW-STD-MIB)- the pwIndex.
An entry is created in this table by the agent for every
entry in the pwTable with a pwType equal to one of the
following:
e1Satop(17), t1Satop(18), e3Satop(19), t3Satop(20),
basicCesPsn(21), basicTdmIp(22), tdmCasCesPsn(23),
tdmCasTdmIp(24)."
INDEX { pwTDMoIpCfgTableIndex }
::= { pwTDMoIpCfgTable 1 }
PwTDMoIpCfgEntry ::= SEQUENCE {
pwTDMoIpCfgTableIndex Unsigned32,
pwTDMoIpCfgRowStatus RowStatus,
pwTDMoIpCfgPayloadFormat INTEGER,
pwTDMoIpCfgFarEndType INTEGER,
pwTDMoIpCfgDelaySensitivity INTEGER,
pwTDMoIpCfgFramesInPacket Unsigned32
}
pwTDMoIpCfgTableIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index to an entry in this table"
::= { pwTDMoIpCfgEntry 1}
pwTDMoIpCfgRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Object used for creating, modifying, and deleting
a row of this table."
::= { pwTDMoIpCfgEntry 2 }
pwTDMoIpCfgPayloadFormat OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
v1 (2),
v2 (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"determine TDM over IP proprietary
payload format."
::= { pwTDMoIpCfgEntry 3 }
pwTDMoIpCfgFarEndType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
dsx1E1 (2), --E1
dsx1ESF (3), --T1 (ESF)
dsx1SF (4), --T1 (SF)
unframed (5) -- Serial
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Determines TDM over IP Far End type."
::= { pwTDMoIpCfgEntry 4 }
pwTDMoIpCfgDelaySensitivity OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),--Accurate Clock
enable (3) --Constant Delay
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Determines whether to optimize the clock
for accurateness or for constant delay:
o Disable (Accurate clock is more important than constant delay)
o Enable (Constant delay is more important than accurate clock).
This parameter is applicable only if PSN Type
is TDMoIP , CESoIP, SATOP "
::= { pwTDMoIpCfgEntry 5 }
pwTDMoIpCfgFramesInPacket OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"UDP payload length - determines the ethernet packet size "
::= { pwTDMoIpCfgEntry 6 }
-- *** ATM Service
radPwServiceCfgAtm OBJECT IDENTIFIER ::= { radPwServiceCfgObjects 2}
pwAtmCfgXTable OBJECT-TYPE
SYNTAX SEQUENCE OF PwAtmCfgXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of pwAtmCfgTable
of PW-ATM-R-MIB. Each row that is added/removed there
will be added/removed in this table."
::= { radPwServiceCfgAtm 1 }
pwAtmCfgXEntry OBJECT-TYPE
SYNTAX PwAtmCfgXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is indexed by pwIdx, the value of which is equal
to the same index that was created for the associated entry
in the PW Table (in the PW-STD-MIB)- the pwIndex.
An entry may be created by Agent in this table for
pseudo wires having ATM pwType"
INDEX { pwIdx }
::= { pwAtmCfgXTable 1 }
PwAtmCfgXEntry ::= SEQUENCE {
pwAtmCfgAal5Mode INTEGER,
pwAtmCfgAal5SduTermType INTEGER,
pwAtmCfgTimeout Unsigned32
}
pwAtmCfgAal5Mode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This objects defines whether AAL5 Mode is enabled for this PW."
::= { pwAtmCfgXEntry 1 }
pwAtmCfgAal5SduTermType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
atm (2),
router (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This objects defines the AAL5-SDU Termination Type.
It means - where should the AAL5-SDU PW frame, received from PSN, be forwarded:
atm(2) - forwarded into ATM VCC.
router(3) - forwarded into router.
."
::= { pwAtmCfgXEntry 2 }
pwAtmCfgTimeout OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Timeout period, measured in usec.
Timeout mechanism is used in order to send out a packet
before the maximum concatenated cells limit has been reached."
::= { pwAtmCfgXEntry 3 }
-- ***Frame Relay Service PW Table
radPwServiceCfgFr OBJECT IDENTIFIER ::= { radPwServiceCfgObjects 3}
pwFrCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PwFrCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains a set of parameters for
Frame Relay PW in the pwFrTable."
::= { radPwServiceCfgFr 1 }
pwFrCfgEntry OBJECT-TYPE
SYNTAX PwFrCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"These parameters define the characteristics of a
Frame Relay PW.
This table is indexed by pwIdx, the value of which is equal
to the same index that was created for the associated entry
in the PW Table (in the PW-STD-MIB)- the pwIndex.
An entry may be created by Agent in this table for
pseudo wires having Frame Relay pwType"
INDEX { pwIdx }
::= { pwFrCfgTable 1 }
PwFrCfgEntry ::= SEQUENCE {
pwFrCfgDlciFieldLength Unsigned32,
pwFrCfgBitMarking BITS,
pwFrCfgDlci Unsigned32
}
pwFrCfgDlciFieldLength OBJECT-TYPE
SYNTAX Unsigned32 (10|17|24)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DLCI Field length in bytes. Possible values ae
10, 17 or 24"
::= { pwFrCfgEntry 1 }
pwFrCfgBitMarking OBJECT-TYPE
SYNTAX BITS
{
pwFrDeIncomingMarking (0),
pwFrFecnIncomingMarking (1),
pwFrBecnIncomingMarking (2),
pwFrDeOutgoingMarking (3),
pwFrFecnOutgoingMarking (4),
pwFrBecnOutgoingMarking (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines which Frame Relay bits are copied
into the outgoing interface or from the incoming interface.
When labeled bit is 1, FR bit is copied.
For incoming FR bits - DE, FECN and BECN:
DE - pwFrDeIncomingMarking
FECN - pwFrFecnIncomingMarking
BECN - pwFrBecnIncomingMarking
For outgoing FR bits - DE, FECN and BECN:
DE - pwFrDeOutgoingMarking
FECN - pwFrFecnOutgoingMarking
BECN - pwFrBecnOutgoingMarking "
::= { pwFrCfgEntry 2 }
pwFrCfgDlci OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DLCI value of Frame Relay VC associated with this PW."
::= { pwFrCfgEntry 3 }
-- PW Performance
pwPerfCurrentXTable OBJECT-TYPE
SYNTAX SEQUENCE OF PwPerfCurrentXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of pwPerfCurrentTable (PW-STD-R-MIB)."
::= { radPwPerfMonitoring 1 }
pwPerfCurrentXEntry OBJECT-TYPE
SYNTAX PwPerfCurrentXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in a table."
INDEX { pwIdx }
::= { pwPerfCurrentXTable 1 }
PwPerfCurrentXEntry ::= SEQUENCE {
pwPerfCurrentInCongestDropPackets PerfCurrentCount,
pwPerfCurrentOutCongestDropPackets PerfCurrentCount
}
pwPerfCurrentInCongestDropPackets OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter for number of received packets that are dropped
due to congestion by the PW (from the PSN)
in the current 15-minute interval."
::= { pwPerfCurrentXEntry 1 }
pwPerfCurrentOutCongestDropPackets OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter for number of transmitted packets that are dropped
due to congestion by the PW (to the PSN)
in the current 15-minute interval."
::= { pwPerfCurrentXEntry 2 }
pwPerfIntervalXTable OBJECT-TYPE
SYNTAX SEQUENCE OF PwPerfIntervalXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of pwPerfIntervalTable (PW-STD-R-MIB)."
::= { radPwPerfMonitoring 2 }
pwPerfIntervalXEntry OBJECT-TYPE
SYNTAX PwPerfIntervalXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in a table."
INDEX { pwIdx, pwPerfIntervalXNumber }
::= { pwPerfIntervalXTable 1 }
PwPerfIntervalXEntry ::= SEQUENCE {
pwPerfIntervalXNumber Integer32,
pwPerfIntervalInCongestDropPackets PerfIntervalCount,
pwPerfIntervalOutCongestDropPackets PerfIntervalCount
}
pwPerfIntervalXNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number N, between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval, and the interval identified
by N is the interval immediately preceding the one
identified by N-1.
The minimum range of N is 1 through 4. The default range
is 1 to 32. The maximum range of N is 1 through 96."
::= { pwPerfIntervalXEntry 1 }
pwPerfIntervalInCongestDropPackets OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter for number of received packets that are dropped
due to congestion by the PW (to the PSN) during the interval."
::= { pwPerfIntervalXEntry 2 }
pwPerfIntervalOutCongestDropPackets OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter for number of transmitted packets that are dropped
due to congestion by the PW (to the PSN) during the interval."
::= { pwPerfIntervalXEntry 3 }
-- ATM PW Performance
pwAtmPerfCurrentXTable OBJECT-TYPE
SYNTAX SEQUENCE OF PwAtmPerfCurrentXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of pwArmPerfCurrentTable (PW-ATM-R-MIB)."
::= { radPwPerfMonitoring 3 }
pwAtmPerfCurrentXEntry OBJECT-TYPE
SYNTAX PwAtmPerfCurrentXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in a table."
INDEX { pwIdx }
::= { pwAtmPerfCurrentXTable 1 }
PwAtmPerfCurrentXEntry ::= SEQUENCE
{
pwAtmPerfCurrentInDiscardTotalCells PerfCurrentCount,
pwAtmPerfCurrentInDiscardClp0Cells PerfCurrentCount,
pwAtmPerfCurrentTaggedCells PerfCurrentCount
}
pwAtmPerfCurrentInDiscardTotalCells OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of total received cells (CLP0 and CLP1)
that were discarded by the traffic policer,
in the current 15-minute interval."
::= { pwAtmPerfCurrentXEntry 1 }
pwAtmPerfCurrentInDiscardClp0Cells OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received CLP0 cells
that were discarded by the traffic policer,
in the current 15-minute interval."
::= { pwAtmPerfCurrentXEntry 2 }
pwAtmPerfCurrentTaggedCells OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of cells that were tagged
by the traffic policer from CLP=0 to CLP=1,
in the current 15-minute interval."
::= { pwAtmPerfCurrentXEntry 3 }
pwAtmPerfIntervalXTable OBJECT-TYPE
SYNTAX SEQUENCE OF PwAtmPerfIntervalXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of pwAtmPerfIntervalTable (PW-ATM-R-MIB)."
::= { radPwPerfMonitoring 4 }
pwAtmPerfIntervalXEntry OBJECT-TYPE
SYNTAX PwAtmPerfIntervalXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in a table."
INDEX { pwIdx, pwAtmPerfIntervalXNumber }
::= { pwAtmPerfIntervalXTable 1 }
PwAtmPerfIntervalXEntry ::= SEQUENCE
{
pwAtmPerfIntervalXNumber Integer32,
pwAtmPerfIntervalInDiscardTotalCells PerfIntervalCount,
pwAtmPerfIntervalInDiscardClp0Cells PerfIntervalCount,
pwAtmPerfIntervalTaggedCells PerfIntervalCount
}
pwAtmPerfIntervalXNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number N, between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval, and the interval identified
by N is the interval immediately preceding the one
identified by N-1.
The minimum range of N is 1 through 4. The default range
is 1 to 32. The maximum range of N is 1 through 96."
::= { pwAtmPerfIntervalXEntry 1 }
pwAtmPerfIntervalInDiscardTotalCells OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of total received cells (CLP0 and CLP1)
that were discarded by the traffic policer,
during the interval."
::= { pwAtmPerfIntervalXEntry 2 }
pwAtmPerfIntervalInDiscardClp0Cells OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received CLP0 cells
that were discarded by the traffic policer,
during the interval."
::= { pwAtmPerfIntervalXEntry 3 }
pwAtmPerfIntervalTaggedCells OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of cells that were tagged
by the traffic policer from CLP=0 to CLP=1,
during the interval."
::= { pwAtmPerfIntervalXEntry 4 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\mpls.txt
--
-- RAD Multi-Protocol Label Switching (MPLS) Text file
-- Version: 5.40
-- First Version Date: 22-Aug-2006
-- By: Yig'al Hachmon
-- File: mpls.txt
-- Last update: 14-Jan-2008 by Shay Harari
radMplsNotifications OBJECT IDENTIFIER ::= { radMpls 0 }
radMplsCfgObjects OBJECT IDENTIFIER ::= { radMpls 1 }
mplsMinStaticIngressLabel OBJECT-TYPE
SYNTAX MplsLabel
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the minimum value of a static MPLS ingress label
that is supported by the device."
::= { radMplsCfgObjects 1 }
mplsMaxStaticIngressLabel OBJECT-TYPE
SYNTAX MplsLabel
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the maximum value of static
MPLS ingress label that is supported by the device"
::= { radMplsCfgObjects 2 }
mplsMinIngressDynamicLabel OBJECT-TYPE
SYNTAX MplsLabel
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the minimum value of a dynamic MPLS ingress label
that is supported by the device."
::= { radMplsCfgObjects 3 }
mplsMaxIngressDynamicLabel OBJECT-TYPE
SYNTAX MplsLabel
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the maximum value of a dynamic
MPLS ingress label that is supported by the device"
::= { radMplsCfgObjects 4 }
mplsIngressTunnelIndexNext OBJECT-TYPE
SYNTAX IndexIntegerNextFree
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an unused value for
mplsIngressTunnelIndex, or a zero to indicate
that none exist. Negative values are not allowed,
as they do not correspond to valid values of
mplsTunnelIndex.
Note that this object offers an unused value
for an mplsTunnelIndex value at the ingress
side of a tunnel. "
::= { radMplsCfgObjects 5 }
mplsIngressTunnelTable OBJECT-TYPE
SYNTAX SEQUENCE OF MplsIngressTunnelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mpls Ingress Tunnel Table"
::= { radMplsCfgObjects 6 }
mplsIngressTunnelEntry OBJECT-TYPE
SYNTAX MplsIngressTunnelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents an MPLS tunnel.
An entry can be created by a network administrator
or by an SNMP agent as instructed by an MPLS
signaling protocol. "
INDEX { mplsIngressTunnelIndex }
::= { mplsIngressTunnelTable 1 }
MplsIngressTunnelEntry ::= SEQUENCE {
mplsIngressTunnelIndex MplsTunnelIndex,
mplsIngressTunnelName SnmpAdminString,
mplsIngressTunnelOwner MplsOwner,
mplsIngressTunnelAttachedInterface InterfaceIndexOrZero,
mplsIngressTunnelNumberOfLabels Unsigned32,
mplsIngressTunnelAdminStatus INTEGER,
mplsIngressTunnelOuterLabel Unsigned32,
mplsIngressTunnelInnerLabel Unsigned32,
mplsIngressTunnelRowStatus RowStatus,
mplsIngressTunnelPWCounter Gauge32,
mplsIngressTunnelOperStatus INTEGER
}
mplsIngressTunnelIndex OBJECT-TYPE
SYNTAX MplsTunnelIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ingress Tunnel index."
::= { mplsIngressTunnelEntry 1 }
mplsIngressTunnelName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The name assigned to the ingress tunnel."
DEFVAL {""}
::= { mplsIngressTunnelEntry 2 }
mplsIngressTunnelOwner OBJECT-TYPE
SYNTAX MplsOwner
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Denotes the entity (or protocol) that created and is responsible
for managing this tunnel."
::= { mplsIngressTunnelEntry 3 }
mplsIngressTunnelAttachedInterface OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The incoming interface leads
to a predefined ifindex based on connection type."
::= { mplsIngressTunnelEntry 4 }
mplsIngressTunnelNumberOfLabels OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of tunnel labels that should be received
on this ingress tunnel.
This number does not include the pW label"
::= { mplsIngressTunnelEntry 5 }
mplsIngressTunnelAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1), -- ready to pass packets
down(2),
testing(3) -- in some test mode
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the desired operational status of this
tunnel."
::= { mplsIngressTunnelEntry 6 }
mplsIngressTunnelOuterLabel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Label that is 'closer' to the network encapsulation."
::= { mplsIngressTunnelEntry 7 }
mplsIngressTunnelInnerLabel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Label that is 'closer' to the user payload."
::= { mplsIngressTunnelEntry 8 }
mplsIngressTunnelRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Object used for creating, modifying, and deleting
a row of this table"
::= { mplsIngressTunnelEntry 9 }
mplsIngressTunnelPWCounter OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Pseudo Wires that use the ingress tunnel."
::= { mplsIngressTunnelEntry 10 }
mplsIngressTunnelOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up (1),
down (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the operational status of this ingress tunnel."
::= { mplsIngressTunnelEntry 11 }
mplsEgressTunnelIndexNext OBJECT-TYPE
SYNTAX IndexIntegerNextFree
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an unused value for
mplsEgressTunnelIndex, or a zero to indicate
that none exist. Negative values are not allowed,
as they do not correspond to valid values of
mplsTunnelIndex.
Note that this object offers an unused value
for an mplsTunnelIndex value at the egress
side of a tunnel. "
::= { radMplsCfgObjects 7 }
mplsEgressTunnelTable OBJECT-TYPE
SYNTAX SEQUENCE OF MplsEgressTunnelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mpls Egress Tunnel Table"
::= { radMplsCfgObjects 8 }
mplsEgressTunnelEntry OBJECT-TYPE
SYNTAX MplsEgressTunnelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents an MPLS tunnel.
An entry can be created by a network administrator
or by an SNMP agent as instructed by an MPLS
signalling protocol."
INDEX { mplsEgressTunnelIndex }
::= { mplsEgressTunnelTable 1 }
MplsEgressTunnelEntry ::= SEQUENCE {
mplsEgressTunnelIndex MplsTunnelIndex,
mplsEgressTunnelName SnmpAdminString,
mplsEgressTunnelOwner MplsOwner,
mplsEgressTunnelAttachedInterface InterfaceIndexOrZero,
mplsEgressTunnelNextHopType INTEGER,
mplsEgressTunnelNextHop Unsigned32,
mplsEgressTunnelIpNextHop IpAddress,
mplsEgressTunnelNumberOfLabels Unsigned32,
mplsEgressTunnelAdminStatus INTEGER,
mplsEgressTunnelOuterLabel Unsigned32,
mplsEgressTunnelInnerLabel Unsigned32,
mplsEgressTunnelRowStatus RowStatus,
mplsEgressTunnelPWCounter Gauge32,
mplsEgressTunnelPeerIdx Unsigned32,
mplsEgressTunnelExpBitsMode INTEGER,
mplsEgressTunnelExpBits Unsigned32,
mplsEgressTunnelOperStatus INTEGER
}
mplsEgressTunnelIndex OBJECT-TYPE
SYNTAX MplsTunnelIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Egress Tunnel index ."
::= { mplsEgressTunnelEntry 1 }
mplsEgressTunnelName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The name assigned to the egress tunnel."
DEFVAL {""}
::= { mplsEgressTunnelEntry 2 }
mplsEgressTunnelOwner OBJECT-TYPE
SYNTAX MplsOwner
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Denotes the entity (or protocol) that created and is responsible
for managing this tunnel."
::= { mplsEgressTunnelEntry 3 }
mplsEgressTunnelAttachedInterface OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The outgoing interface leads
to a predefined ifindex based on connection type."
::= { mplsEgressTunnelEntry 4 }
mplsEgressTunnelNextHopType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
atmVc (2),
bridgePort (3),
ipV4 (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates address type of the Next Hop.
Not applicable for device with router."
::= { mplsEgressTunnelEntry 5 }
mplsEgressTunnelNextHop OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Not applicable (=0) when mplsEgressTunnelNextHopType=notApplicable.
When applicable, represents ATM VC, Bridge Port,
according to mplsEgressTunnelNextHopType."
::= { mplsEgressTunnelEntry 6}
mplsEgressTunnelIpNextHop OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Applicable only when mplsEgressTunnelNextHopType =ipV4."
::= { mplsEgressTunnelEntry 7}
mplsEgressTunnelNumberOfLabels OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of Tunnel Labels that should be transmitted
on this egress LSP (Labeled-Switched Path).
This number of labels does not include the PW number.
Valid values 0 - no label, 1, 2"
::= { mplsEgressTunnelEntry 8 }
mplsEgressTunnelAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1), -- ready to pass packets
down(2),
testing(3) -- in some test mode
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the desired operational status of this
egress tunnel."
::= { mplsEgressTunnelEntry 9 }
mplsEgressTunnelOuterLabel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Label that is 'closer' to the network encapsulation."
::= { mplsEgressTunnelEntry 10 }
mplsEgressTunnelInnerLabel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Label that is 'closer' to the user payload."
::= { mplsEgressTunnelEntry 11 }
mplsEgressTunnelRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Object used for creating, modifying, and deleting
a row of this table"
::= { mplsEgressTunnelEntry 12 }
mplsEgressTunnelPWCounter OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Pseudo Wires that use the egress tunnel."
::= { mplsEgressTunnelEntry 13 }
mplsEgressTunnelPeerIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Represents the Index of the Peer (as it is defined in the Peer Table),
for which this egress tunnel should be established."
::= { mplsEgressTunnelEntry 14 }
mplsEgressTunnelExpBitsMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
copyFromPw (2),
static (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the EXP Bits Mode of this egress tunnel:
copyFromPw(2)- EXP Bits of this tunnel are copied from the EXP bits
of the PW, as configured for the PW.
static(3) - EXP Bits value is set to a fixed value,
specifies in mplsEgressTunnelExpBits.
."
::= { mplsEgressTunnelEntry 15 }
mplsEgressTunnelExpBits OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the EXP Bits of this egress tunnel.
Relevant only when EXP Bits Mode is 'static(3)'."
::= { mplsEgressTunnelEntry 16 }
mplsEgressTunnelOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up (1),
down (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the operational status of this egress tunnel."
::= { mplsEgressTunnelEntry 17 }
mplsPhpMode OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable represents the PHP (Penultimate Hop Popping) Mode
of the device."
::= { radMplsCfgObjects 9 }
radMplsLdp OBJECT IDENTIFIER ::= { radMpls 2 }
radMplsLdpCfgObjects OBJECT IDENTIFIER ::= { radMplsLdp 1 }
--
-- The MPLS LDP Entity Table
-- Table is based on 'mplsLdpEntityTable' from MPLS-LDP-STD-MIB (RFC 3815)
--
radMplsLdpEntityTable OBJECT-TYPE
SYNTAX SEQUENCE OF MplsLdpEntityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains information about the
MPLS Label Distribution Protocol Entities which
exist on this Label Switching Router (LSR)
or Label Edge Router (LER)."
::= { radMplsLdpCfgObjects 1 }
radMplsLdpEntityEntry OBJECT-TYPE
SYNTAX MplsLdpEntityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents an LDP entity.
An entry can be created by a network administrator
or by an SNMP agent as instructed by LDP."
INDEX { radMplsLdpEntityLdpId, radMplsLdpEntityIndex }
::= { radMplsLdpEntityTable 1 }
MplsLdpEntityEntry ::= SEQUENCE {
radMplsLdpEntityLdpId MplsLdpIdentifier, -- Leaf 1
radMplsLdpEntityIndex IndexInteger, -- Leaf 2
-- Leaf 3 reserved
radMplsLdpEntityAdminStatus INTEGER, -- Leaf 4
-- Leaf 5 reserved
-- Leaf 6 reserved
-- Leaf 7 reserved
-- Leaf 8 reserved
radMplsLdpEntityKeepAliveHoldTimer Unsigned32, -- Leaf 9
radMplsLdpEntityHelloHoldTimer Unsigned32, -- Leaf 10
-- Leaf 11 reserved
-- Leaf 12 reserved
-- Leaf 13 reserved
-- Leaf 14 reserved
-- Leaf 15 reserved
-- Leaf 16 reserved
-- Leaf 17 reserved
-- Leaf 18 reserved
-- Leaf 19 reserved
-- Leaf 20 reserved
-- Leaf 21 reserved
-- Leaf 22 reserved
radMplsLdpEntityRowStatus RowStatus -- Leaf 23
}
radMplsLdpEntityLdpId OBJECT-TYPE
SYNTAX MplsLdpIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The LDP identifier.
When irrelevant, value = (2^48)-1 (all ones in all 6 octets)."
::= { radMplsLdpEntityEntry 1 }
radMplsLdpEntityIndex OBJECT-TYPE
SYNTAX IndexInteger
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This index is used as a secondary index to uniquely
identify this row.
A secondary index (this object) is meaningful to some
but not all, LDP implementations. For example
an LDP implementation which uses PPP would
use this index to differentiate PPP sub-links.
Another way to use this index is to give this the
value of ifIndex. However, this is dependant
on the implementation.
When irrelevant, value = value = (2^32)-1 (all ones in all bits)."
::= { radMplsLdpEntityEntry 2 }
-- { radMplsLdpEntityEntry 3 } reserved
radMplsLdpEntityAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable (1),
disable (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The administrative status of this LDP Entity.
If this object is changed from 'enable' to 'disable'
and this entity has already attempted to establish
contact with a Peer, then all contact with that
Peer is lost and all information from that Peer
needs to be removed from the MIB. (This implies
that the network management subsystem should clean
up any related entry in the mplsLdpPeerTable. This
further implies that a 'tear-down' for that session
is issued and the session and all information related
to that session cease to exist).
At this point the operator is able to change values
which are related to this entity.
When the admin status is set back to 'enable', then
this Entity will attempt to establish a new session
with the Peer."
::= { radMplsLdpEntityEntry 4 }
-- { radMplsLdpEntityEntry 5 } reserved
-- { radMplsLdpEntityEntry 6 } reserved
-- { radMplsLdpEntityEntry 7 } reserved
-- { radMplsLdpEntityEntry 8 } reserved
radMplsLdpEntityKeepAliveHoldTimer OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The 16-bit integer value which is the proposed keep
alive hold timer for this LDP Entity."
::= { radMplsLdpEntityEntry 9 }
radMplsLdpEntityHelloHoldTimer OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The 16-bit integer value which is the proposed Hello
hold timer for this LDP Entity. The Hello Hold time
in seconds.
An LSR maintains a record of Hellos received
from potential peers. This object represents
the Hold Time in the Common Hello Parameters TLV of
the Hello Message.
A value of 0 is a default value and should be
interpretted in conjunction with the
radMplsLdpEntityTargetPeer object.
If the value of this object is 0: if the value of the
radMplsLdpEntityTargetPeer object is false(2), then this
specifies that the Hold Time's actual default value is
15 seconds (i.e., the default Hold time for Link Hellos
is 15 seconds). Otherwise if the value of the
radMplsLdpEntityTargetPeer object is true(1), then this
specifies that the Hold Time's actual default value is
45 seconds (i.e., the default Hold time for Targeted
Hellos is 45 seconds).
A value of 65535 means infinite (i.e., wait forever).
All other values represent the amount of time in
seconds to wait for a Hello Message. Setting the
hold time to a value smaller than 15 is not
recommended, although not forbidden according
to RFC3036."
::= { radMplsLdpEntityEntry 10 }
-- { radMplsLdpEntityEntry 11 } reserved
-- { radMplsLdpEntityEntry 12 } reserved
-- { radMplsLdpEntityEntry 13 } reserved
-- { radMplsLdpEntityEntry 14 } reserved
-- { radMplsLdpEntityEntry 15 } reserved
-- { radMplsLdpEntityEntry 16 } reserved
-- { radMplsLdpEntityEntry 17 } reserved
-- { radMplsLdpEntityEntry 18 } reserved
-- { radMplsLdpEntityEntry 19 } reserved
-- { radMplsLdpEntityEntry 20 } reserved
-- { radMplsLdpEntityEntry 21 } reserved
-- { radMplsLdpEntityEntry 22 } reserved
radMplsLdpEntityRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this conceptual row. All writable
objects in this row may be modified at any
time, however, as described in detail in
the section entitled, 'Changing Values After
Session Establishment', and again described
in the DESCRIPTION clause of the
radMplsLdpEntityAdminStatus object, if a session
has been initiated with a Peer, changing objects
in this table will wreak havoc with the session
and interrupt traffic. To repeat again:
the recommended procedure is to
set the radMplsLdpEntityAdminStatus to down, thereby
explicitly causing a session to be torn down. Then,
change objects in this entry, then set
the radMplsLdpEntityAdminStatus to enable,
which enables a new session to be initiated."
::= { radMplsLdpEntityEntry 23 }
-- Based on 'mplsLdpLsrId' (RO) from MPLS-LDP-STD-MIB (RFC 3815)
radMplsLdpLsrId OBJECT-TYPE
SYNTAX MplsLsrIdentifier
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Label Switching Router's Identifier."
::= { radMplsLdpCfgObjects 2 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\radDs0.txt
--
-- Title: RAD-DS0 MIB
--
-- Copyright 1998 RAD Data Communications, Ltd.
-- All Rights Reserved.
--
-- RAD-DS0 MIB
--
--Title: RAD's DS0 Bundle MIB
--Date: 13.09.06
--By: Liora Gafni
--File: radds0.txt
-- Last updated by Orly Bachar 2-May-2007
ds0BundleIf OBJECT IDENTIFIER ::= {diverseIfWanGen 15} -- see mpmx.txt for all interfaces
-- Extension to the standard dsx0 bundle table
ds0BundleTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ds0BundleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains additional objects for the standard dsx0BundleTable."
::= { ds0BundleIf 1 }
ds0BundleEntry OBJECT-TYPE
SYNTAX Ds0BundleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry augmenting the standard dsx0BundleEntry."
AUGMENTS { dsx0BundleEntry }
::= { ds0BundleTable 1 }
Ds0BundleEntry ::=
SEQUENCE
{
ds0BundleTsBitFilter INTEGER,
ds0BundleUserDefTsBitFilter Integer32,
ds0BundleTdmPortNum Unsigned32,
ds0BundleTimeslotMask Unsigned32
}
ds0BundleTsBitFilter OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
f64Kbps (2),
f56Kbps (3),
userDefined (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Filter for controlling the bandwidth of the bundle.
The TS Bit Filter contains 8 bits (Hex): 00..FF.
When a bit is 0: it means that no data will be Tx/Rx on this bit.
For example: FF means 64K. In this case all 8 bits will be Tx/Rx.
f64Kbps - Bit Filter will be FF
f56Kbps - Bit Filter will be FE
userDefined - Filter will defined by the user via ds0BundleUserDefTsBitFilter.
For Vmux - this object is used to define the ML Card Channelized Bundle BW."
::= { ds0BundleEntry 1 }
ds0BundleUserDefTsBitFilter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"User Defined Filter for controlling the bandwidth of the bundle.
This MIB object is relevant only when ds0BundleTsBitFilter = userDefined (4)
This object is useful for users who want to define a special Filter
that cannot be defined via ds0BundleTsBitFilter.
The TS Bit Filter contains 8 bits (Hex): 00..FF.
When a bit is 0: it means that no data will be Tx/Rx on this bit."
::= { ds0BundleEntry 2 }
ds0BundleTdmPortNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter indicates the TDM port number that the bundle
is associated to."
::= { ds0BundleEntry 3 }
ds0BundleTimeslotMask OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter indicates the timeslots allocated for the bundle:
Each bit represents a timeslot. Setting a bit to '1' denotes that
the corresponding timeslot is allocated for that bundle.
Bit 0 is not in use, since timeslot 0 is never assigned."
::= { ds0BundleEntry 4 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\radPdh.txt
--
-- RAD-PDH-MIB DEFINITIONS ::= BEGIN
--
--Title: RAD's PDH INTERFACE MIB
--Version: 1.0
--Date: 15-Nov-06
--By: Liora Gafni
--File: radpdh.txt
--
--Last update: 19-Nov-2006 by Liora Gafni
pdhInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 16}
pdhIfConfig OBJECT IDENTIFIER ::= { pdhInterface 1 } -- Node for configuration
pdhIfStatus OBJECT IDENTIFIER ::= { pdhInterface 2 } -- Node for status
pdhIfStatis OBJECT IDENTIFIER ::= { pdhInterface 3 } -- Node for statistics
-- C O N F I G U R A T I O N
-- PDH (Plesiochronous Digital Hierarchy) logical port/interface configuration
pdhLogPrtConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF PdhLogPrtConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration for PDH (Plesiochronous Digital Hierarchy) Logical
ports/interfaces.
For example: GFP (Generic Framing Procedure) logical interface
or VCG (Virtual Concatenation Group) logical interface."
::= { pdhIfConfig 1 }
pdhLogPrtConfigEntry OBJECT-TYPE
SYNTAX PdhLogPrtConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in Configuration Table for PDH Logical Ports."
INDEX {pdhLogPrtCnfgIdx,pdhLogPrtIndex}
::= { pdhLogPrtConfigTable 1 }
PdhLogPrtConfigEntry ::=
SEQUENCE
{
pdhLogPrtCnfgIdx Integer32,
pdhLogPrtIndex Unsigned32,
pdhLogPrtMaxDiffDelay Unsigned32
}
-- Note: for the parameter Payload FCS, see radgen.txt: gfpPayloadFcs (gfpCnfgTable)
pdhLogPrtCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Index of the Configuration being accessed.
Index of 255 relates to the Temporary/Edit (Scratch) Configuration.
For products that support several configurations, Set can be performed
only to the Temporary Config (=255).
For products that don't support Temporary/Edit (Scratch) configuration,
this index will be 1."
::= { pdhLogPrtConfigEntry 1}
pdhLogPrtIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the number or ifIndex of the selected logical port."
::= { pdhLogPrtConfigEntry 2 }
pdhLogPrtMaxDiffDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum Differential Delay.
Largest allowed difference in msec. between delays in two links (E1/T1)
that are members of the selected VCG.
This object is relevant for VCG (Virtual Concatenation Group) only."
::= { pdhLogPrtConfigEntry 3 }
-- S T A T U S
-- PDH (Plesiochronous Digital Hierarchy) Logical Port Status
pdhLogPrtStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PdhLogPrtStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status of PDH logical port"
::= { pdhIfStatus 1 }
pdhLogPrtStatusEntry OBJECT-TYPE
SYNTAX PdhLogPrtStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the PDH Logical Port Status Table"
INDEX { pdhLogPrtStatusIndex }
::= { pdhLogPrtStatusTable 1 }
PdhLogPrtStatusEntry ::=
SEQUENCE
{
pdhLogPrtStatusIndex Unsigned32,
pdhLogPrtFrameDelineation INTEGER,
pdhLogPrtDiffDelay Unsigned32
}
pdhLogPrtStatusIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the number or ifIndex of the selected logical port."
::= { pdhLogPrtStatusEntry 1 }
pdhLogPrtFrameDelineation OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
notDelineated (2),
delineated (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is relevant for GFP (Generic Framing Procedure) only.
It indicates the GFP Frame delineation status.
Frame delineation means that the device has found the start of a frame -
the protocol is synchronized"
::= { pdhLogPrtStatusEntry 2 }
pdhLogPrtDiffDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Differential Delay.
This object indicates the largest detected difference in msec. between
delays in two links (E1/T1) that are members of the selected VCG."
::= { pdhLogPrtStatusEntry 3 }
-- VCG LCAS (Link Capacity Adjustment Scheme) Members Status table
vcgLcasMembersStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF VcgLcasMembersStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status for LCAS (Link Capacity Adjustment Scheme) members (links) of VCG
logical port."
::= { pdhIfStatus 2 }
vcgLcasMembersStatusEntry OBJECT-TYPE
SYNTAX VcgLcasMembersStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in LCAS (Link Capacity Adjustment Scheme) links status table for
VCG (Virtual Concatenation Group) logical port."
INDEX { vcgLcasMembersVcgIndex, vcgLcasMembersLinkIndex }
::= { vcgLcasMembersStatusTable 1 }
VcgLcasMembersStatusEntry ::=
SEQUENCE
{
vcgLcasMembersVcgIndex Unsigned32,
vcgLcasMembersLinkIndex Unsigned32,
vcgLcasMembersSourceStatus INTEGER,
vcgLcasMembersSinkStatus INTEGER
}
vcgLcasMembersVcgIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the number or ifIndex of the selected VCG
(Virtual Concatenation Group) logical port."
::= { vcgLcasMembersStatusEntry 1 }
vcgLcasMembersLinkIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the number or ifIndex of the PDH link
that is a member of the VCG."
::= { vcgLcasMembersStatusEntry 2 }
vcgLcasMembersSourceStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
fail (2),
ok (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object summarizes the LCAS status of the source (Tx) side of the link."
::= { vcgLcasMembersStatusEntry 3 }
vcgLcasMembersSinkStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
fail (2),
ok (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object summarizes the LCAS status of the sink (Rx) side of the link."
::= { vcgLcasMembersStatusEntry 4 }
-- S T A T I S T I C S
-- PDH (Plesiochronous Digital Hierarchy) Logical Port Statistics
pdhLogPrtStatisTable OBJECT-TYPE
SYNTAX SEQUENCE OF PdhLogPrtStatisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Statistics for PDH (Plesiochronous Digital Hierarchy) Logical Port,
currently used for GFP (Generic Framing Procedure) interface."
::= { pdhIfStatis 1 }
pdhLogPrtStatisEntry OBJECT-TYPE
SYNTAX PdhLogPrtStatisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in Statistics Table for PDH (Plesiochronous Digital Hierarchy) Logical Port."
INDEX { pdhLogPrtStatisIndex }
::= { pdhLogPrtStatisTable 1 }
PdhLogPrtStatisEntry ::=
SEQUENCE
{
pdhLogPrtStatisIndex Unsigned32,
pdhLogPrtStatisRxCorrFrames Counter32,
pdhLogPrtStatisRxCorrOctets Counter32,
pdhLogPrtStatisRxCHecErrors Counter32,
pdhLogPrtStatisRxTHecErrors Counter32,
pdhLogPrtStatisRxFcsErrors Counter32
}
pdhLogPrtStatisIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the number or ifIndex of the selected Interface."
::= { pdhLogPrtStatisEntry 1 }
pdhLogPrtStatisRxCorrFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the total number of Correct Frames received."
::= { pdhLogPrtStatisEntry 2 }
pdhLogPrtStatisRxCorrOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the total number of Correct Octets received."
::= { pdhLogPrtStatisEntry 3 }
pdhLogPrtStatisRxCHecErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the total number of Frames received with errors in
the Core header (i.e. cHEC field. cHEC means Core Header Error Correction)."
::= { pdhLogPrtStatisEntry 4 }
pdhLogPrtStatisRxTHecErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the total number of Frames received with errors in
the Type header (i.e. tHEC field. tHEC means Type Header Error Correction)."
::= { pdhLogPrtStatisEntry 5 }
pdhLogPrtStatisRxFcsErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the total number of Frames received with Frame
Check Sequence errors."
::= { pdhLogPrtStatisEntry 6 }
--
-- file :D:\Synergy\WorkArea\545\mib_rad\txt\radEms.txt
--
--Title: RAD EMS MIB
--Version: 540
--Date: 16-August-07
--By: Smadar Tauber
--File: radEms.txt
--
--Last update: 30-March-2008 by Smadar Tauber
--This branch of MIB deals with objects implemented by EMS towards an OSS (other
--vendor's NMS)
radEMS OBJECT IDENTIFIER ::= { rad 15 } -- RAD EMS
radEmsEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events sent by RAD EMS to other vendor's NMS."
::= { radEMS 0 }
emsTrapData OBJECT IDENTIFIER ::= { radEMS 1 }
emsTrapSeverity OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"EMS will send this object as an attached parameter, of traps sent
to another vendor's NMS.
It will include the Severity configured by user for the respective
trap via Admin Console of the Fault Management.
The implementation was done so that the string includes characters of
digits, while each digit represents a severity, as follows:
'0' - undefined
'1' - normal
'2' - indeterminate
'3' - warning
'4' - minor
'5' - major
'6' - critical "
::= { emsTrapData 1 }
emsEventSeverity OBJECT-TYPE
SYNTAX INTEGER
{
undefined(0),
normal(1),
indeterminate(2),
warning(3),
minor(4),
major(5),
critical(6)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"EMS Event Severity by enumerated integer."
::= { emsTrapData 2 }
emsTrapOriginatorAddress OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The Address of the trap originator (when trap is forwarded)."
::= { emsTrapData 3 }
emsTrapOriginatorNodeName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Node Name given in EMS to the trap originator."
::= { emsTrapData 4 }
emsEventClassName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Event Class Name assigned in EMS."
::= { emsTrapData 5 }
emsEventInstance OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Instance assigned to Event by EMS."
::= { emsTrapData 6 }
emsEventDescription OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Description assigned to this Event in EMS."
::= { emsTrapData 7 }
emsEventType OBJECT-TYPE
SYNTAX INTEGER
{
raise(1), --problem
clear(2) --resolution
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Event Type assigned by EMS."
::= { emsTrapData 8 }
emsEventOperation OBJECT-TYPE
SYNTAX INTEGER
{
noOperation(0),
noAck(1),
ack(2),
delete(3),
delete-all(4)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"EMS operation related to this Event."
::= { emsTrapData 9 }
emsNodeId OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The EMS ID of the Node. Unique 64-bit identifier."
::= { emsTrapData 10 }
emsName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"EMS station name."
::= { emsTrapData 11 }
emsUserName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"EMS User Name (User who performed emsEventOperation).
When emsEventOperation=noOperation(0), the string will be 'NA'."
::= { emsTrapData 12 }
--NOTIFICATIONS
emsEventLogSizeStatusChange NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent in order to provide certain size changes of EMS Event Log.
It is periodically generated and sent when EMS discovers that Event Log
size exceeds Major or Critical thresholds defined by user (relative to
maximum capacity) or when Event Log returns to Normal size."
::= { radEmsEvents 1 }
emsEventGenericTrap NOTIFICATION-TYPE
OBJECTS { emsTrapOriginatorAddress, -- Address of the trap originator
emsTrapOriginatorNodeName, -- EMS Name of the trap originator
emsEventClassName, -- Name of Event Class, assigned in EMS
emsEventInstance, -- Event Instance assigned in EMS
emsEventSeverity, -- Event Severity assigned in EMS
emsEventDescription,-- Event Description assigned in EMS
emsEventType, -- Event Type assigned by EMS
emsEventOperation, -- EMS operation related to this Event
emsNodeId, -- EMS ID of the trap originator
emsName, -- EMS station name
emsUserName -- EMS User Name (related to Operation)
}
STATUS current
DESCRIPTION
"Generic trap forwarding facility. Used for integration purposes between
RADview EMS and other systems, for example Netcool."
::= { radEmsEvents 2 }
END