NSCRTV-HFCEMS-ANALOG-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises
FROM RFC1155-SMI
DisplayString
FROM SNMPv2-TC ;
nscrtvRoot OBJECT IDENTIFIER ::= { enterprises 17409 }
-- DESCRIPTION
-- "NscrtvRoot definition of the National Radio and Television Standardization Technical Committee MIB root nodes"
nscrtvHFCemsTree OBJECT IDENTIFIER ::= { nscrtvRoot 1 }
-- DESCRIPTION
-- "NscrtvHFCemsTree definition HFC network equipment management system MIB root nodes,"
-- "All HFC network equipment management system should be in the MIB definition of nodes"
propertyIdent OBJECT IDENTIFIER ::= { nscrtvHFCemsTree 1}
-- DESCRIPTION
-- "Attribute (Property) MIB branch nodes logo"
-- "See Appendix C"
alarmsIdent OBJECT IDENTIFIER ::= { nscrtvHFCemsTree 2}
-- DESCRIPTION
-- "¸æ¾¯(Alarms)MIBµÄ·ÖÖ§½Úµã±êʶ Alarms MIB branch nodes logo"
-- "See Appendix D"
commonIdent OBJECT IDENTIFIER ::= { nscrtvHFCemsTree 3}
-- DESCRIPTION
-- "Utility (Common) MIB branch nodes logo"
-- "See Appendix E"
oswIdent OBJECT IDENTIFIER ::= { nscrtvHFCemsTree 15}
-- DESCRIPTION
-- "Optical switch MIB branch node identifier."
--**********************************************************************************************
-- analog MIB
--**********************************************************************************************
analogPropertyTable OBJECT-TYPE
SYNTAX SEQUENCE OF AnalogPropertyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Simulation parameters attribute table."
::= { propertyIdent 1 }
analogPropertyEntry OBJECT-TYPE
SYNTAX AnalogPropertyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Attribute Table simulation parameters head.OID purpose as a table index, the coding method is 'length + OID.' OID before two members of the '130' is based on '1' and '3' respectively coding, and not ordinary OID encoding (0x2B)."
INDEX { analogParameterOID }
::= { analogPropertyTable 1 }
AnalogPropertyEntry ::= SEQUENCE {
analogParameterOID
OBJECT IDENTIFIER,
alarmEnable
OCTET STRING,
analogAlarmState
INTEGER,
analogAlarmHIHI
INTEGER,
analogAlarmHI
INTEGER,
analogAlarmLO
INTEGER,
analogAlarmLOLO
INTEGER,
analogAlarmDeadband
INTEGER
}
analogParameterOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"index"
::= { analogPropertyEntry 1 }
alarmEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm enable control byte, the corresponding position for the'1 'that allow alarm,'0' a ban warning
Bit 0: Alarm enable low
Bit 1: Alarm enable low
Bit 2: Alarm enable high
Bit 3: Alarm enable high
Bit 4 ~ 7 reservations should be 0
This object should be stored in nonvolatile memory."
::= { analogPropertyEntry 2 }
analogAlarmState OBJECT-TYPE
SYNTAX INTEGER {
aasNominal (1),
aasHIHI (2),
aasHI (3),
aasLO (4),
aasLOLO (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The parameters of the current state of alarm."
::= { analogPropertyEntry 3 }
analogAlarmHIHI OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The parameters of the current state of alarm."
::= { analogPropertyEntry 4 }
analogAlarmHI OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"HI high alarm threshold value. This object should be stored in non-volatile memory"
::= { analogPropertyEntry 5 }
analogAlarmLO OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LO low alarm threshold value. This object should be stored in nonvolatile memory"
::= { analogPropertyEntry 6 }
analogAlarmLOLO OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm LOLO very low threshold value. This object should be stored in nonvolatile memory."
::= { analogPropertyEntry 7 }
analogAlarmDeadband OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Dead-alarm threshold value. After the warning, parameter values should be restored to the alarm threshold and alarm threshold and the difference between the absolute value greater than the value of dead zone, the alarm can be removed.This object should be stored in nonvolatile memory."
::= { analogPropertyEntry 8 }
-- *
-- * ÀëÉ¢ÊôÐÔ±í
-- * ÀëÉ¢ÊôÐÔ±íµÄ¼Ç¼ÊýÁ¿Êǹ̶¨µÄ£¬Ã¿¸öÀëÉ¢ÐͲÎÊýµÄÿһ¸öÐèÒª½øÐи澯´¦ÀíµÄÖµÔÚ±í
-- * Öоù¶ÔÓ¦Ò»Ìõ¼Ç¼¡£Ã¿¸öÀëÉ¢ÐͲÎÊýÔÚÀëÉ¢ÊôÐÔ±íÖÐÖÁÉÙ¶ÔÓ¦ÓÐÒ»Ìõ¼Ç¼¡£
-- * ÀëÉ¢ÊôÐÔ±íÓÐ2¸öË÷Òý£ºÒ»¸öÊDzÎÊý±êʶ£¨OID£©£¬ÁíÒ»¸öÊÇÀëÉ¢¸æ¾¯Öµ£¨discreteAlarmValue£©¡£
-- *
discretePropertyTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiscretePropertyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Discrete Attribute Table"
::= { propertyIdent 2 }
discretePropertyEntry OBJECT-TYPE
SYNTAX DiscretePropertyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Attribute Table discrete head. OID coding methods with simulation attribute table."
INDEX { discreteParameterOID, discreteAlarmValue }
::= { discretePropertyTable 1 }
DiscretePropertyEntry ::= SEQUENCE {
discreteParameterOID
OBJECT IDENTIFIER,
discreteAlarmValue
INTEGER,
discreteAlarmEnable
INTEGER,
discreteAlarmState
INTEGER
}
discreteParameterOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Attribute Table discrete index 1: Parameters OID"
::= { discretePropertyEntry 1 }
discreteAlarmValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Attribute Table discrete index 2: parameter values.When the equipment value of this parameter values, and so will be dealt with a warning"
::= { discretePropertyEntry 2 }
discreteAlarmEnable OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enableMajor (2),
enableMinor (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When the alarm so that it can open the (2 or 3), this parameter allows for alarm processin
If the alarm so that it can shut down (1), alarm processing will be carried out.
This object default values for the disable (1).
This object should be stored in non-volatile memory"
::= { discretePropertyEntry 3 }
discreteAlarmState OBJECT-TYPE
SYNTAX INTEGER {
dasNominal(1),
dasDiscreteMajor(6),
dasDiscreteMinor(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The parameters of the current state of alarm"
::= { discretePropertyEntry 4 }
currentAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF CurrentAlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current alarm table."
::= { propertyIdent 3 }
currentAlarmEntry OBJECT-TYPE
SYNTAX CurrentAlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current warning Table Head. OID coding methods with simulation attribute table"
INDEX { currentAlarmOID }
::= { currentAlarmTable 1 }
CurrentAlarmEntry ::= SEQUENCE {
currentAlarmOID
OBJECT IDENTIFIER,
currentAlarmState
INTEGER,
currentAlarmValue
INTEGER
}
currentAlarmOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NE, currently in a state of alarm parameters OID Index, and the alarm in the table attribute parameters OID counterparts."
::= { currentAlarmEntry 1 }
currentAlarmState OBJECT-TYPE
SYNTAX INTEGER {
caasHIHI (2),
caasHI (3),
caasLO (4),
caasLOLO (5),
caasDiscreteMajor (6),
caasDiscreteMinor (7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Warning parameters of the current state of alarm"
::= { currentAlarmEntry 2 }
currentAlarmValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm parameter values."
::= { currentAlarmEntry 3 }
--************************************************************************************************
-- alarm MIB
--************************************************************************************************
alarmLogNumberOfEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm record number of records in the table"
::= { alarmsIdent 1 }
alarmLogLastIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Recently a warning the index of the records."
::= { alarmsIdent 2 }
alarmLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmLogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm record form, at least support 16 record. Each table in the registration of a new record, the management agent (transponder) managers should send traps news"
::= { alarmsIdent 3 }
alarmLogEntry OBJECT-TYPE
SYNTAX AlarmLogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm Sheet Head"
INDEX { alarmLogIndex }
::= { alarmLogTable 1 }
AlarmLogEntry ::=
SEQUENCE
{
alarmLogIndex
INTEGER,
alarmLogInformation
OCTET STRING
}
alarmLogIndex OBJECT-TYPE
SYNTAX INTEGER (1..32767)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The only logo Alarm Index recorded a record in the table, the index value increased from 1 start of each new record, plus 1 until 32767, under a record index of the re-starts at 1. Acting under the management of storage capacity can be the first choice to delete those records, the specific details in this not to achieve requirements."
::= { alarmLogEntry 1 }
alarmLogInformation OBJECT-TYPE
SYNTAX OCTET STRING ( SIZE ( 17..255 ) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm record information, multi-byte strings, defined as follows:
Byte 1 ~ 4: Alarm in time (POSIX format, the previous maximum byte)
Byte 5: Alarm types (enumeration, definitions¼ûºó)
Byte 6: Alarm value after commonNeStatus
Byte 7 ~ m: Alarm parameters object identifier (Basic Encoding Rules (ASN.1))
Byte n ~ z: Alarm parameter values (Basic Encoding Rules (ASN.1))
Alarm enumerated types:
1 NOMINAL
2 HIHI
3 HI
4 LO
5 LOLO
6 Discrete Major
7 Discrete Minor"
::= { alarmLogEntry 2 }
alarmText OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS optional
DESCRIPTION
"This trap targets for the needs of information contained in a text field transponder information is achievable.The field contains the text of the object depends on the definition of alarm parameters, it is uncertain, Provisions of this object can not access."
::= { alarmsIdent 4 }
hfcAlarmEvent TRAP-TYPE
ENTERPRISE nscrtvHFCemsTree
VARIABLES { commonPhysAddress, commonNELogicalID, alarmLogInformation, alarmText }
DESCRIPTION
"When detected in the event of alarm information sent this trap, whether bundled alarmText variable parameter under warning object to determine. Some of the parameters only need to bind the alarm first three variables"
::= 1
--***********************************************************************************************
-- common MIB
--**********************************************************************************************
-- *
-- * Common MIB
-- *
commonAdminGroup OBJECT IDENTIFIER ::= { commonIdent 1 }
commonAdminUseRf OBJECT IDENTIFIER ::= { commonIdent 2 }
commonAdminUseEthernet OBJECT IDENTIFIER ::= { commonIdent 3 }
commonMACGroup OBJECT IDENTIFIER ::= { commonAdminUseRf 1 }
commonRfGroup OBJECT IDENTIFIER ::= { commonAdminUseRf 2 }
commonMacAddress OBJECT IDENTIFIER ::= { commonMACGroup 1 }
commonBackoffParams OBJECT IDENTIFIER ::= { commonMACGroup 2 }
commonMacStats OBJECT IDENTIFIER ::= { commonMACGroup 3 }
commonAgentGroup OBJECT IDENTIFIER ::= { commonAdminUseEthernet 1 }
commonDeviceGroup OBJECT IDENTIFIER ::= { commonAdminUseEthernet 2 }
-- *************
-- * NE
-- *************
commonNELogicalID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..40))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The logic of the designated NE identifier (LogicID), the values and attributes of other unrelated NE.This target value should be stored in non-volatile memory"
::= { commonAdminGroup 1 }
commonNEVendor OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NE equipment manufacturers¡£"
::= { commonAdminGroup 2 }
commonNEModelNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { commonAdminGroup 3 }
commonNESerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NE equipment serial numbers"
::= { commonAdminGroup 4 }
commonNEVendorInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS optional
DESCRIPTION
"NE equipment suppliers other special designated information"
::= { commonAdminGroup 5 }
commonNEStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"With 7.5.4 STATRESP PDU in the corresponding parameters Status
Bit 0: CHNLRQST
Bit 1: CNTNRM
Bit 2: CNTCUR
Bit 3: MAJOR ALARMS
Bit 4: MINOR ALARMS
Bit 5: RSVD1
Bit 6: RSVD2
Bit 7: RSVD3"
::= { commonAdminGroup 6 }
commonReset OBJECT-TYPE
SYNTAX INTEGER { reset (1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Write'1 'will be reset NE equipment, the value will be included in other non-functional. Reading this object return value'1 ', the equipment had no effect¡£"
::= { commonAdminGroup 7 }
commonAlarmDetectionControl OBJECT-TYPE
SYNTAX INTEGER {
detectionDisabled (1),
detectionEnabled (2),
detectionEnabledAndRegenerate (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object used to control the Alarm Detection NE.When the attribute table or discrete simulation attribute table MIB objects to a set threshold, that alarm has occurred and, as recorded in the latest warning alarm Sheet (alarmLogTable) add one warning traps will also produce.
If the value of a MIB object is not normal, and the current alarm in the table (currentAlarmTable) will also add a record.DetectionDisabled (1) will stop and simulation Attribute Table / Attribute Table associated discrete alarm detection process, NE will no longer have a warning.
DetectionEnabled (2) allow the alarm detection, detection from detectionEnabled be set in which the transponder before beginning continue. DetectionEnabledAndRegenerate (3) removal of all information and allow Warning Alarm Detection conducted.
Attribute Table and discrete simulation attribute table of all alarm attributes will be returned to the alarm before the normal operation of the.
Any still in a state of alarm attributes will not have a 'return to normal' warning, set this value will remove warning and the current record sheet alarmLogTable Alarm Table currentAlarmTable content.
DetectionEnabledAndRegenerate role is temporary, as will be set to detectionEnabledAndRegnerate commonAlarmDetectionControl after its SNMP response includes this value, if read beyond this target value, the response to detectionEnabled.DetectionDisabled hfcColdStart or value does not affect the selection of hfcWarmStart traps.Future additional traps in its description unless there are specific provisions in Otherwise they would be free from the impact of this object.
This object should be stored in nonvolatile memory, the default values for detectionEnabled"
::= { commonAdminGroup 8 }
commonNetworkAddress OBJECT-TYPE
SYNTAX NetworkAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NE network IP address, NE produce Trap should include this address. This value should be stored in nonvolatile memory. This value can be registered through the MAC order or through the local interface vendors to set up."
::= { commonAdminGroup 9 }
commonCheckCode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This target for the detection transponder code configuration of the report. The calculation includes detection code transponder (including management equipment) and the physical configuration parameters stored in non-volatile memory of all the parameters. The detection algorithm calculated by the vendor code provisions.
The object should be kept in the value of non-volatile memory, the response thinks highly activated, will be recalculated and re-testing code and the value prior to the commencement of comparison to determine whether or should haveÒ»¸öhfcColdStart hfcWarmStart traps.
When write this object (SetRequest), the detection code will be recalculated and fill the SetRequest in response to the GetResponse. At this time, will not produce hfcColdStart or hfcWarmStart traps."
::= { commonAdminGroup 10 }
commonTrapCommunityString OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Definition of Community Trap string. The default value is' public '"
::= { commonAdminGroup 11 }
commonTamperStatus OBJECT-TYPE
SYNTAX INTEGER { intact (1), compromised (2) }
ACCESS read-only
STATUS optional
DESCRIPTION
"The safety report NE switching equipment (such as whether to open up the lid) state that this object is called discrete attributes of a corresponding entry in the table. Intact that normal, compromised expressed alarm"
::= { commonAdminGroup 12 }
commonInternalTemperature OBJECT-TYPE
SYNTAX INTEGER (-128..127)
ACCESS read-only
STATUS optional
DESCRIPTION
"NE equipment Room (machine) temperature, units degrees Celsius. This request object attribute in a corresponding entry in the table"
::= { commonAdminGroup 13 }
commonTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION
"NE of the POSIX said that the current time (since at 0:00 on January 1, 1970 since the seconds)."
::= { commonAdminGroup 14 }
commonVarBindings OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object can be said to receive SNMP information NE variables bundled the largest number of tables. Value: 0 indicated no restrictions on the maximum number bundled"
::= { commonAdminGroup 15 }
commonResetCause OBJECT-TYPE
SYNTAX INTEGER {
other (1),
powerup (2),
command (3),
watchdog (4),
craft (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NE said the reasons for the recent reduction."
::= { commonAdminGroup 16 }
commonCraftStatus OBJECT-TYPE
SYNTAX INTEGER {
disconnected (1),
connected (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NE local object that this interface (such as RS232 or RS485 interface) state. NE does not necessarily have to support the local interface. NE local interface without affecting the state of its MAC interface functions; If we do not support the local interface, and its value is disconnected."
::= { commonAdminGroup 17 }
commonDeviceOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS optional
DESCRIPTION
"This OID object as a pointer, the equipment was used at MIB (such as Node, two-way amplifier, etc.). "
::= { commonAdminGroup 18 }
commonDeviceId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(32))
ACCESS read-only
STATUS optional
DESCRIPTION
"The contents of this object by the designated by the equipment vendors, manufacturers and products it contains special ASCII text messages"
::= { commonAdminGroup 19 }
-- ****************
-- * NE PhysAddress
-- ****************
commonPhysAddress OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NE physical address"
::= { commonMacAddress 1 }
commonMaxMulticastAddresses OBJECT-TYPE
SYNTAX INTEGER (4..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NE equipment to support the greatest number of multicast addresses."
::= { commonMacAddress 2 }
commonMulticastAddressTable OBJECT-TYPE
SYNTAX SEQUENCE OF CommonMulticastAddressEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Multicast addresses Table, the value of this object should be stored in nonvolatile memory."
::= { commonMacAddress 3 }
commonMulticastAddressEntry OBJECT-TYPE
SYNTAX CommonMulticastAddressEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Multicast addresses head table."
INDEX { commonMulticastAddressIndex }
::= { commonMulticastAddressTable 1 }
CommonMulticastAddressEntry ::=
SEQUENCE
{
commonMulticastAddressIndex
INTEGER,
commonMulticastAddressNumber
OCTET STRING
}
commonMulticastAddressIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Multicast addresses head table."
::= { commonMulticastAddressEntry 1 }
commonMulticastAddressNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Multicast address, I / G-1 effective."
::= { commonMulticastAddressEntry 2 }
commonBackoffPeriod OBJECT-TYPE
SYNTAX INTEGER (0..16383)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Backoff algorithm benchmark time (ms), initialize the default value of 6 ms.The value of this object should be stored in nonvolatile memory."
::= { commonBackoffParams 1 }
commonACKTimeoutWindow OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NE awaiting HE overtime to send ACK response time (ms), initialize the default value is 19 ms.The value of this object should be stored in nonvolatile memory."
::= { commonBackoffParams 2 }
commonMaximumMACLayerRetries OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NE data packets sent the greatest number of re-examination. Initialize the default value is 16.The value of this object should be stored in nonvolatile memory."
::= { commonBackoffParams 3 }
commonMaxPayloadSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"From top to bottom line channel packet supported by the largest payload (payload) the length of"
::= { commonBackoffParams 4 }
commonBackoffMinimumExponent OBJECT-TYPE
SYNTAX INTEGER (0..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The standards body of the MAC layer specification definition of the smallest backoff algorithm index value, default values for 6.This value may not exceed commonBackoffMaximumValue value.The value of this object should be stored in nonvolatile memory."
::= { commonBackoffParams 5 }
commonBackoffMaximumExponent OBJECT-TYPE
SYNTAX INTEGER (0..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The body of the MAC layer standard definition of backoff algorithm for standardizing the largest index value, the default value is 15.This value shall be not less than commonBackoffMinimum value.The value of this object should be stored in nonvolatile memory."
::= { commonBackoffParams 6 }
commonForwardPathLOSEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-write
STATUS optional
DESCRIPTION
"LOS downlink channel in the number of reset to 0."
::= { commonMacStats 1 }
commonForwardPathFramingErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-write
STATUS optional
DESCRIPTION
"Downlink Channel frames wrong number reset to 0."
::= { commonMacStats 2 }
commonForwardPathCRCErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-write
STATUS optional
DESCRIPTION
"CRC errors down the number of reset to 0."
::= { commonMacStats 3 }
commonInvalidMacCmds OBJECT-TYPE
SYNTAX Counter
ACCESS read-write
STATUS optional
DESCRIPTION
"Invalid MAC layer order wrong number reset to 0."
::= { commonMacStats 4 }
commonBackwardPathCollisionTimes OBJECT-TYPE
SYNTAX Counter
ACCESS read-write
STATUS optional
DESCRIPTION
"Uplink Packet collision frequency, reset to 0."
::= { commonMacStats 5 }
commonReturnPathFrequency OBJECT-TYPE
SYNTAX INTEGER (0..1000000000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channel uplink frequency units Hz.The value of this object should be stored in non-volatile memory"
::= { commonRfGroup 1 }
commonForwardPathFrequency OBJECT-TYPE
SYNTAX INTEGER (0..1000000000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Downlink frequency channel, flat Hz.The value of this object should be stored in nonvolatile memory."
::= { commonRfGroup 2 }
commonProvisionedReturnPowerLevel OBJECT-TYPE
SYNTAX INTEGER (0..127)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Upstream channel power levels and units for dBuV.When the internal use of this value will be rounded to the nearest support value. Reading return to this subject when the actual value rather than rounding value.The value of this object should be stored in nonvolatile memory."
::= { commonRfGroup 3 }
commonForwardPathReceiveLevel OBJECT-TYPE
SYNTAX INTEGER (0..127)
ACCESS read-only
STATUS optional
DESCRIPTION
"Downlink Channel receive power levels, units dBuV."
::= { commonRfGroup 4 }
commonMaxReturnPower OBJECT-TYPE
SYNTAX INTEGER (0..127)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The largest upstream channel power levels and units for dBuV.The value of this object should be stored in nonvolatile memory."
::= { commonRfGroup 5 }
commonAgentBootWay OBJECT-TYPE
SYNTAX INTEGER {
bootDefault (1),
bootBOOTP (2),
bootTFTP (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { commonAgentGroup 1 }
commonAgentReset OBJECT-TYPE
SYNTAX INTEGER { reset(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Acting Restart, write'1 'will enable agents to restart, the value will be included in other non-functional. Reading this object return value'1 ', the agent had no effect"
::= { commonAgentGroup 2 }
commonAgentMaxTraps OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Acting detected alarm when sent to the management of the largest number of TRAP, 0 that manufacturers use the default default values"
::= { commonAgentGroup 3 }
commonAgentTrapMinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Acting TRAP send the minimum spacing units"
::= { commonAgentGroup 4 }
commonAgentTrapMaxInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Acting TRAP send the largest spacing units for"
::= { commonAgentGroup 5 }
commonTrapAck OBJECT-TYPE
SYNTAX OCTET STRING ( SIZE ( 17..255 ) )
ACCESS read-write
STATUS optional
DESCRIPTION
"The variables used to notify Snmp agents, it issued the warning Trap has received information management console, do not have to re-hair. The content of the variables in alarmLogInformation MIB and the same warning. Agents received after the adoption of alarmLogInformation management can clearly know the host response is a warning which Trap information, thereby stop the alarm Trap weight of the information."
::= { commonAgentGroup 6 }
commonAgentTrapTable OBJECT-TYPE
SYNTAX SEQUENCE OF CommonAgentTrapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Acting Information Table TRAP"
::= { commonAgentGroup 7 }
commonAgentTrapEntry OBJECT-TYPE
SYNTAX CommonAgentTrapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Acting Head TRAP Information Table"
INDEX { commonAgentTrapIndex }
::= { commonAgentTrapTable 1 }
CommonAgentTrapEntry ::= SEQUENCE {
commonAgentTrapIndex
INTEGER,
commonAgentTrapIP
IpAddress,
commonAgentTrapCommunity
DisplayString,
commonAgentTrapStatus
INTEGER
}
commonAgentTrapIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TRAP Table Index"
::= { commonAgentTrapEntry 1 }
commonAgentTrapIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When the purpose of the TRAP host's IP address"
::= { commonAgentTrapEntry 2 }
commonAgentTrapCommunity OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Send the Community string TRAP"
::= { commonAgentTrapEntry 3 }
commonAgentTrapStatus OBJECT-TYPE
SYNTAX INTEGER {
commonAgentTrapEnable (1),
commonAgentTrapDisable (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"It said that the opening of TRAP"
::= { commonAgentTrapEntry 4 }
commonDeviceNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The agent said that the current management is the number of devices"
::= { commonDeviceGroup 1 }
commonDeviceInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF CommonDeviceInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Acting is currently public information management equipment list."
::= { commonDeviceGroup 2 }
commonDeviceInfoEntry OBJECT-TYPE
SYNTAX CommonDeviceInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Acting is currently public information management equipment list Table Head."
INDEX { commonDeviceSlot }
::= { commonDeviceInfoTable 1 }
CommonDeviceInfoEntry ::= SEQUENCE {
commonDeviceSlot
INTEGER,
commonDevicesID
OCTET STRING,
commonDeviceVendor
DisplayString,
commonDeviceModelNumber
DisplayString,
commonDeviceSerialNumber
DisplayString,
commonDeviceVendorInfo
DisplayString,
commonDeviceStatus
OCTET STRING,
commonDeviceReset
INTEGER,
commonDeviceAlarmDetectionControl
INTEGER,
commonDeviceMACAddress
NetworkAddress,
commonDeviceTamperStatus
INTEGER,
commonDeviceInternalTemperature
INTEGER,
commonDeviceResetCause
INTEGER,
commonDeviceCraftStatus
INTEGER,
commonDevicesOID
OBJECT IDENTIFIER,
commonDeviceAcct
Counter,
commonDeviceName
DisplayString,
commonDeviceMFD
DisplayString,
commonDeviceFW
DisplayString
}
commonDeviceSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Acting is currently under the management of the equipment list of public information table index."
::= { commonDeviceInfoEntry 1 }
commonDevicesID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..40))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Designated equipment manufacturers logo"
::= { commonDeviceInfoEntry 2 }
commonDeviceVendor OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Equipment manufacturers"
::= { commonDeviceInfoEntry 3 }
commonDeviceModelNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Equipment models."
::= { commonDeviceInfoEntry 4 }
commonDeviceSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The string of equipment."
::= { commonDeviceInfoEntry 5 }
commonDeviceVendorInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS optional
DESCRIPTION
"Equipment suppliers of other special designated information"
::= { commonDeviceInfoEntry 6 }
commonDeviceStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"
Bit 0: RSVD0
Bit 1: RSVD1
Bit 2: RSVD2
Bit 3: MAJOR ALARMS
Bit 4: MINOR ALARMS
Bit 5: RSVD5
Bit 6: RSVD6
Bit 7: RSVD7"
::= { commonDeviceInfoEntry 7 }
commonDeviceReset OBJECT-TYPE
SYNTAX INTEGER { reset (1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Write'1 'will be reset equipment, other values will be written into the non-functional. Reading this object return value'1 ', the equipment had no effect."
::= { commonDeviceInfoEntry 8 }
commonDeviceAlarmDetectionControl OBJECT-TYPE
SYNTAX INTEGER {
detectionDisabled (1),
detectionEnabled (2),
detectionEnabledAndRegenerate (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object used to control equipment alarm detection. "
::= { commonDeviceInfoEntry 9 }
commonDeviceMACAddress OBJECT-TYPE
SYNTAX NetworkAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Equipment MAC address"
::= { commonDeviceInfoEntry 10 }
commonDeviceTamperStatus OBJECT-TYPE
SYNTAX INTEGER { intact (1), compromised (2) }
ACCESS read-only
STATUS optional
DESCRIPTION
"Report of the safety switch equipment (such as whether to open up the lid) state that this object is called discrete attributes of a corresponding entry in the table. Intact that normal, compromised expressed alarm."
::= { commonDeviceInfoEntry 11 }
commonDeviceInternalTemperature OBJECT-TYPE
SYNTAX INTEGER (-128..127)
ACCESS read-only
STATUS optional
DESCRIPTION
"Equipment Room (machine) temperature, units degrees Celsius. This request object attribute in a corresponding entry in the table"
::= { commonDeviceInfoEntry 12 }
commonDeviceResetCause OBJECT-TYPE
SYNTAX INTEGER {
other (1),
powerup (2),
command (3),
watchdog (4),
craft (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Equipment that the reasons for the recent reduction"
::= { commonDeviceInfoEntry 13 }
commonDeviceCraftStatus OBJECT-TYPE
SYNTAX INTEGER {
disconnected (1),
connected (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object interface that local equipment (such as RS232 or RS485 interface) state."
::= { commonDeviceInfoEntry 14 }
commonDevicesOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Goals identifier string, point to a concrete realization of the equipment"
::= { commonDeviceInfoEntry 15 }
commonDeviceAcct OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION
"Equipment that the accumulated work time, units of s"
::= { commonDeviceInfoEntry 16 }
commonDeviceName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Equipment name"
::= { commonDeviceInfoEntry 17 }
commonDeviceMFD OBJECT-TYPE
SYNTAX DisplayString (SIZE(10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Equipment manufacturing date."
::= { commonDeviceInfoEntry 18 }
commonDeviceFW OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Equipment firmware information"
::= { commonDeviceInfoEntry 19 }
hfcColdStart TRAP-TYPE
ENTERPRISE nscrtvHFCemsTree
VARIABLES { commonPhysAddress, commonNELogicalID}
DESCRIPTION
"HfcColdStart traps that are sent to re-initialization protocol entities, and entities agent configuration or agreement may have changed. This trap only after the success of transponder sent registration"
::= 0
hfcWarmStart TRAP-TYPE
ENTERPRISE nscrtvHFCemsTree
VARIABLES { commonPhysAddress, commonNELogicalID }
DESCRIPTION
"HfcWarmStart traps that are sent to re-initialization protocol entities, and entities agent configuration or agreement has not changed. This trap only after the completion of transponder sent registration"
::= 2
--*********************************************************************************************
-- Optical Switch MIB
--*********************************************************************************************
oswVendorOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS optional
DESCRIPTION
"This object provides manufacturers of optical switch MIB expansion. Without the expansion, this should be targeting at the optical switch nodes oswIdent"
::= { oswIdent 1 }
oswMode OBJECT-TYPE
SYNTAX INTEGER ( 0..3 )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The work modes of the optical switch:'1' indicates the switch choose route B£»'2' indicates the switch choose route A£»'3' indicates the switch choose any one output route¡£"
::= { oswIdent 2 }
oswSwitch OBJECT-TYPE
SYNTAX INTEGER ( 0..65535 )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Optical switch breaking point"
::= { oswIdent 3 }
-- ****************
-- * ͨµÀ²ÎÊý
-- ****************
oswChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF OswChannelEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Optical Switch Information Table"
::= { oswIdent 4 }
oswChannelEntry OBJECT-TYPE
SYNTAX OswChannelEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Optical Switch Information Table Head"
INDEX { oswIndex }
::= { oswChannelTable 1 }
OswChannelEntry ::=
SEQUENCE
{
oswUnitTemp
INTEGER,
oswInputA
INTEGER,
oswInputB
INTEGER,
oswOutput1
INTEGER,
oswOutput2
INTEGER
}
oswUnitTemp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Chassis temperature of the Optical switch, unit in 1 centigrade degree."
::= { oswChannelEntry 1 }
oswInputA OBJECT-TYPE
SYNTAX INTEGER ( -128..127 )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The input optical power of route A, unit in 0.1 dBm, this object require entry register in the attribute MIB."
::= { oswChannelEntry 2 }
oswInputB OBJECT-TYPE
SYNTAX INTEGER ( -128..127 )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The input optical power of route B, unit in 0.1 dBm, this object require entry register in the attribute MIB."
::= { oswChannelEntry 3 }
oswOutput1 OBJECT-TYPE
SYNTAX INTEGER ( 0..65535 )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The input optical power of route 1, unit in 0.1 dBm, this object require entry register in the attribute MIB."
::= { oswChannelEntry 4 }
oswOutput2 OBJECT-TYPE
SYNTAX INTEGER ( 0..65535 )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The input optical power of route 2, unit in 0.1 dBm, this object require entry register in the attribute MIB."
::= { oswChannelEntry 5 }
-- *****************
-- * Ö±Á÷µçÔ´
-- *****************
oswNumberDCPowerSupply OBJECT-TYPE
SYNTAX INTEGER ( 0..16 )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of internal DC power supply,'0 'indicates the transponder nonsupport this function."
::= { oswIdent 5 }
oswDCPowerSupplyMode OBJECT-TYPE
SYNTAX INTEGER { loadsharing(1), switchedRedundant(2), aloneSupply(3)}
ACCESS read-only
STATUS optional
DESCRIPTION
"Power supply work modes: Load and load-sharing, standby switch, or independency power supply. If the equipment has only one DC power supply, this should not be supported."
::= { oswIdent 6 }
oswDCPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF OswDCPowerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DC Power Information Table"
::= { oswIdent 7 }
oswDCPowerEntry OBJECT-TYPE
SYNTAX OswDCPowerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DC Power Information Table Head"
INDEX { oswDCPowerIndex }
::= { oswDCPowerTable 1 }
OswDCPowerEntry ::=SEQUENCE
{
oswDCPowerIndex
INTEGER,
oswDCPowerVoltage
INTEGER,
oswDCPowerCurrent
INTEGER,
oswDCPowerName
DisplayString
}
oswDCPowerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DC Power Index, table oswDCPowerTable index"
::= { oswDCPowerEntry 1 }
oswDCPowerVoltage OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power supply voltage, unit in 0.1 V, this object require entry register in the attribute MIB."
::= { oswDCPowerEntry 2 }
oswDCPowerCurrent OBJECT-TYPE
SYNTAX INTEGER ( 0..65535 )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power supply current, unit in 0.1 A, this object require entry register in the attribute MIB."
::= { oswDCPowerEntry 3 }
oswDCPowerName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Mark Power supply name, for example: +5 V DC power supply.
This field value regulated by the user, it should be marked with the number of the power supply voltage and distinguish the multi-power supplies at least.
When the object in this table give an alarm, the name of this object should be put into the alarmText target in the hfcAlarmEvent trap.
"
::= { oswDCPowerEntry 4 }
END