Observium_CE/mibs/infinera/INFINERA-PM-ODUI-MIB

258 lines
7.4 KiB
Plaintext

-- *****************************************************************
-- INFINERA-PM-ODU-MIB
-- Copyright (c) 2009-2012 by Infinera Inc.
-- All rights reserved.
-- ****************************************************************
INFINERA-PM-ODUI-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Integer32, Counter64 FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
DisplayString, TruthValue FROM SNMPv2-TC
ifIndex FROM IF-MIB
HCPerfIntervalCount FROM HC-PerfHist-TC-MIB
InfnServiceType,InfnSampleDuration,
InfnValidityBitmap FROM INFINERA-TC-MIB
perfMon FROM INFINERA-REG-MIB;
oduiPmMIB MODULE-IDENTITY
LAST-UPDATED "200907200000Z"
ORGANIZATION "Infinera"
CONTACT-INFO
"Infinera
1322 Bordeaux Drive
Sunnyvale, CA - 94089
Contact : Technical Support
Email : support@infinera.com
Phone : 1-877-INF-5288"
DESCRIPTION
" "
REVISION "200907200000Z"
DESCRIPTION
"First Version"
::= { perfMon 29 }
oduiPmTable OBJECT-TYPE
SYNTAX SEQUENCE OF OduiPmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of ODUI Performance monitoring entries. Each entry is uniquely identified by the value of ifIndex, sampleDuration and oduiPmTimestamp."
::= { oduiPmMIB 2 }
oduiPmEntry OBJECT-TYPE
SYNTAX OduiPmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A ODUI entry containing historical performance information pertaining to Infinera ODUI interfaces.
Entries will exist in this table for interfaces of type ODUI.
Each interface may have a number of entries in this table, each with a different combination of timestamp and sample duration."
INDEX { ifIndex, oduiPmSampleDuration, oduiPmTimestamp }
::= { oduiPmTable 1 }
OduiPmEntry ::= SEQUENCE {
oduiPmTimestamp Integer32,
oduiPmSampleDuration InfnSampleDuration,
oduiPmValidity InfnValidityBitmap,
oduiPmRxDefectSeconds Integer32,
oduiPmCircuitId DisplayString,
oduiPmPayloadType InfnServiceType,
oduiPmRxDefectSecondsFEND Integer32,
oduiPmRxCVP HCPerfIntervalCount,
oduiPmRxBEICount HCPerfIntervalCount
}
oduiPmTimestamp OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"End Time stamp for this interval. If this time is later than the current time,then the data for this bucket is currently being collected."
::= { oduiPmEntry 1 }
oduiPmSampleDuration OBJECT-TYPE
SYNTAX InfnSampleDuration
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The duration of this sample."
::= { oduiPmEntry 2 }
oduiPmValidity OBJECT-TYPE
SYNTAX InfnValidityBitmap
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Flag indicating if data was valid for the entire interval"
::= { oduiPmEntry 3 }
oduiPmRxDefectSeconds OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of Defect seconds on ingress direction."
::= { oduiPmEntry 4 }
oduiPmCircuitId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Circuit ID of the ODUI connection."
::= { oduiPmEntry 5 }
oduiPmPayloadType OBJECT-TYPE
SYNTAX InfnServiceType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Payload type of ODUI."
::= { oduiPmEntry 6 }
oduiPmRxDefectSecondsFEND OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of Defect Seconds on ODUI at ingress"
::= { oduiPmEntry 7 }
oduiPmRxCVP OBJECT-TYPE
SYNTAX HCPerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counter for number of BIP-8 errors at ingress direction"
::= { oduiPmEntry 8 }
oduiPmRxBEICount OBJECT-TYPE
SYNTAX HCPerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Receive BEI count"
::= { oduiPmEntry 9 }
oduiPmRealTable OBJECT-TYPE
SYNTAX SEQUENCE OF OduiPmRealEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of oduiPmReal entries. Each entry is uniquely identified by the value of ifIndex."
::= { oduiPmMIB 1 }
oduiPmRealEntry OBJECT-TYPE
SYNTAX OduiPmRealEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A odui entry containing real-time performance information pertaining to Infinera odui interfaces.
Entries will exist in this table for interfaces of type ODUI."
INDEX { ifIndex }
::= { oduiPmRealTable 1 }
OduiPmRealEntry ::= SEQUENCE {
oduiPmRealRxDefectSeconds Integer32,
oduiPmRealRxDefectSecondsFEND Integer32,
oduiPmRealRxCVP HCPerfIntervalCount,
oduiPmRealRxBEICount HCPerfIntervalCount
}
oduiPmRealRxDefectSeconds OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of Defect seconds on ingress direction."
::= { oduiPmRealEntry 1}
oduiPmRealRxDefectSecondsFEND OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of Defect seconds on far direction."
::= { oduiPmRealEntry 2 }
oduiPmRealRxCVP OBJECT-TYPE
SYNTAX HCPerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counter for number of BIP-8 errors at ingress direction."
::= { oduiPmRealEntry 3 }
oduiPmRealRxBEICount OBJECT-TYPE
SYNTAX HCPerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Receive BEI count."
::= { oduiPmRealEntry 4 }
-- Conformance Statements
oduiPmConformance OBJECT IDENTIFIER ::= { oduiPmMIB 3 }
oduiPmCompliances OBJECT IDENTIFIER ::= { oduiPmConformance 1 }
oduiPmGroups OBJECT IDENTIFIER ::= { oduiPmConformance 2 }
oduiPmCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for conformance to the PM-odui-MIB"
MODULE
MANDATORY-GROUPS { oduiPmGroup }
::= { oduiPmCompliances 1 }
oduiPmRealCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for conformance to the oduiPmReal-MIB"
MODULE
MANDATORY-GROUPS { oduiPmRealGroup }
::= { oduiPmCompliances 2 }
oduiPmGroup OBJECT-GROUP
OBJECTS {
oduiPmTimestamp,
oduiPmSampleDuration,
oduiPmValidity,
oduiPmRxDefectSeconds,
oduiPmCircuitId,
oduiPmPayloadType,
oduiPmRxDefectSecondsFEND,
oduiPmRealRxCVP,
oduiPmRealRxBEICount
}
STATUS current
DESCRIPTION
"A collection of objects for reading the performance of the odui."
::= { oduiPmGroups 1 }
oduiPmRealGroup OBJECT-GROUP
OBJECTS {
oduiPmRealRxDefectSeconds,
oduiPmRealRxDefectSecondsFEND,
oduiPmRealRxCVP,
oduiPmRealRxBEICount
}
STATUS current
DESCRIPTION
"A collection of objects for reading the real-time performance of the ODUI."
::= { oduiPmGroups 2 }
END