Observium_CE/mibs/infinera/INFINERA-PM-FRMSCGPTP-MIB

247 lines
7.0 KiB
Plaintext

-- *****************************************************************
-- INFINERA-PM-FRMSCGPTP-MIB
--
-- October 2013, Rishab Joshi
--
--
-- Copyright (c) 2008-2013 by Infinera Inc.
-- All rights reserved.
-- ****************************************************************
INFINERA-PM-FRMSCGPTP-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Integer32 FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
TruthValue FROM SNMPv2-TC
ifIndex FROM IF-MIB
FloatHundredths, InfnSampleDuration FROM INFINERA-TC-MIB
perfMon FROM INFINERA-REG-MIB;
frmScgPtpPmMIB MODULE-IDENTITY
LAST-UPDATED "201310080000Z"
ORGANIZATION "Infinera"
CONTACT-INFO
"Infinera
1322 Bordeaux Drive
Sunnyvale, CA - 94089
Contact : Technical Support
Email : support@infinera.com
Phone : 1-877-INF-5288"
DESCRIPTION
" "
REVISION "201310080000Z"
DESCRIPTION
"First Version"
::= { perfMon 41 }
frmScgPtpPmTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrmScgPtpPmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of FrmScgPtpPm entries. Each entry is uniquely identified by the value of ifIndex."
::= { frmScgPtpPmMIB 2 }
frmScgPtpPmEntry OBJECT-TYPE
SYNTAX FrmScgPtpPmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A FrmScgPtp entry containing historical performance information pertaining to Infinera OFXSCGPTP.
This table is a subclass of IfCommon. Entries will exist in this table only for interfaces
of type FRMSCGPTP."
INDEX { ifIndex, frmScgPtpPmSampleDuration, frmScgPtpPmTimestamp}
::= { frmScgPtpPmTable 1 }
FrmScgPtpPmEntry ::= SEQUENCE {
frmScgPtpPmTimestamp Integer32,
frmScgPtpPmSampleDuration INTEGER,
frmScgPtpPmValidity TruthValue,
frmScgPtpPmCmnScgOptMin FloatHundredths,
frmScgPtpPmCmnScgOptMax FloatHundredths,
frmScgPtpPmCmnScgOptAve FloatHundredths,
frmScgPtpPmCmnScgOprMin FloatHundredths,
frmScgPtpPmCmnScgOprMax FloatHundredths,
frmScgPtpPmCmnScgOprAve FloatHundredths
}
frmScgPtpPmTimestamp OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"End Time stamp for this interval. If this time is later than the current time,then the data for this bucket is currently being collected."
::= { frmScgPtpPmEntry 1 }
frmScgPtpPmSampleDuration OBJECT-TYPE
SYNTAX INTEGER {
fifteenMinutes(1),
day(2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The duration of this sample."
::= { frmScgPtpPmEntry 2 }
frmScgPtpPmValidity OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Flag indicating if data was valid for the entire interval"
::= { frmScgPtpPmEntry 3 }
frmScgPtpPmCmnScgOptMin OBJECT-TYPE
SYNTAX FloatHundredths
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Minimum FrmScg optical power min."
::= { frmScgPtpPmEntry 4 }
frmScgPtpPmCmnScgOptMax OBJECT-TYPE
SYNTAX FloatHundredths
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Maximum FrmScg optical power max."
::= { frmScgPtpPmEntry 5 }
frmScgPtpPmCmnScgOptAve OBJECT-TYPE
SYNTAX FloatHundredths
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Average FrmScg optical power ave."
::= { frmScgPtpPmEntry 6 }
frmScgPtpPmCmnScgOprMin OBJECT-TYPE
SYNTAX FloatHundredths
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Minimum FrmScg optical power min."
::= { frmScgPtpPmEntry 7}
frmScgPtpPmCmnScgOprMax OBJECT-TYPE
SYNTAX FloatHundredths
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Maximum FrmScg optical power max."
::= { frmScgPtpPmEntry 8}
frmScgPtpPmCmnScgOprAve OBJECT-TYPE
SYNTAX FloatHundredths
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Average FrmScg optical power ave."
::= { frmScgPtpPmEntry 9}
frmScgPtpPmRealTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrmScgPtpPmRealEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of FrmScgPtpPmReal entries. Each entry is uniquely identified by the value of ifIndex."
::= { frmScgPtpPmMIB 1 }
frmScgPtpPmRealEntry OBJECT-TYPE
SYNTAX FrmScgPtpPmRealEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A frmScgPtp entry containing real-time performance information pertaining to Infinera
frmScgPtp interfaces. This table is a subclass of IfCommon."
INDEX { ifIndex }
::= { frmScgPtpPmRealTable 1 }
FrmScgPtpPmRealEntry ::= SEQUENCE {
frmScgPtpPmRealCmnScgOpt FloatHundredths,
frmScgPtpPmRealCmnScgOpr FloatHundredths
}
frmScgPtpPmRealCmnScgOpt OBJECT-TYPE
SYNTAX FloatHundredths
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Total FrmScg optical power trasmit."
::= { frmScgPtpPmRealEntry 1 }
frmScgPtpPmRealCmnScgOpr OBJECT-TYPE
SYNTAX FloatHundredths
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Total FrmScg optical power receive."
::= { frmScgPtpPmRealEntry 2 }
-- Conformance Statements
frmScgPtpPmConformance OBJECT IDENTIFIER ::= { frmScgPtpPmMIB 3 }
frmScgPtpPmCompliances OBJECT IDENTIFIER ::= { frmScgPtpPmConformance 1 }
frmScgPtpPmGroups OBJECT IDENTIFIER ::= { frmScgPtpPmConformance 2 }
frmScgPtpPmCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for conformance to the frmScgPtp-MIB"
MODULE
MANDATORY-GROUPS { frmScgPtpPmGroup }
::= { frmScgPtpPmCompliances 1 }
frmScgPtpPmRealCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for conformance to the FrmScgPtpPmReal-MIB"
MODULE
MANDATORY-GROUPS { frmScgPtpPmRealGroup }
::= { frmScgPtpPmCompliances 2 }
frmScgPtpPmGroup OBJECT-GROUP
OBJECTS {
frmScgPtpPmTimestamp,
frmScgPtpPmSampleDuration,
frmScgPtpPmValidity,
frmScgPtpPmCmnScgOptMin,
frmScgPtpPmCmnScgOptMax,
frmScgPtpPmCmnScgOptAve,
frmScgPtpPmCmnScgOprMin,
frmScgPtpPmCmnScgOprMax,
frmScgPtpPmCmnScgOprAve
}
STATUS current
DESCRIPTION
" A collection of objects for reading the historical performance of the frmScgPtp."
::= { frmScgPtpPmGroups 1 }
frmScgPtpPmRealGroup OBJECT-GROUP
OBJECTS {
frmScgPtpPmRealCmnScgOpt,
frmScgPtpPmRealCmnScgOpr
}
STATUS current
DESCRIPTION
" A collection of objects for reading the real-time performance of the frmScgPtp."
::= { frmScgPtpPmGroups 2 }
END