229 lines
6.6 KiB
Plaintext
229 lines
6.6 KiB
Plaintext
-- *****************************************************************
|
|
-- INFINERA-PM-FEEDPTP-MIB
|
|
--
|
|
-- Copyright (c) 2008-2013 by Infinera Inc.
|
|
-- All rights reserved.
|
|
-- ****************************************************************
|
|
|
|
INFINERA-PM-FEEDPTP-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
Integer32 FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
|
|
DisplayString, TruthValue FROM SNMPv2-TC
|
|
ifIndex FROM IF-MIB
|
|
FloatHundredths FROM INFINERA-TC-MIB
|
|
perfMon FROM INFINERA-REG-MIB;
|
|
|
|
|
|
feedPtpPmMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201310080000Z"
|
|
ORGANIZATION "Infinera"
|
|
CONTACT-INFO
|
|
"Infinera
|
|
1322 Bordeaux Drive
|
|
Sunnyvale, CA - 94089
|
|
|
|
Contact : Technical Support
|
|
Email : support@infinera.com
|
|
Phone : 1-877-INF-5288"
|
|
DESCRIPTION
|
|
" "
|
|
REVISION "201310080000Z"
|
|
DESCRIPTION
|
|
"First Version"
|
|
::= { perfMon 46 }
|
|
|
|
|
|
feedPtpPmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FeedPtpPmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of FeedPtpPm entries. Each entry is uniquely identified by the value of ifIndex."
|
|
::= { feedPtpPmMIB 2 }
|
|
|
|
feedPtpPmEntry OBJECT-TYPE
|
|
SYNTAX FeedPtpPmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A FeedPtp entry containing historical performance information pertaining to Infinera .
|
|
This table is a subclass of IfCommon. Entries will exist in this table only for interfaces
|
|
of type ."
|
|
INDEX { ifIndex, feedPtpPmSampleDuration, feedPtpPmTimestamp}
|
|
::= { feedPtpPmTable 1 }
|
|
|
|
|
|
FeedPtpPmEntry ::= SEQUENCE {
|
|
feedPtpPmTimestamp Integer32,
|
|
feedPtpPmSampleDuration INTEGER,
|
|
feedPtpPmValidity TruthValue,
|
|
feedPtpPmInputVoltageMin FloatHundredths,
|
|
feedPtpPmInputVoltageMax FloatHundredths,
|
|
feedPtpPmInputVoltageAve FloatHundredths,
|
|
feedPtpPmInputCurrentMin FloatHundredths,
|
|
feedPtpPmInputCurrentMax FloatHundredths,
|
|
feedPtpPmInputCurrentAve FloatHundredths
|
|
}
|
|
feedPtpPmTimestamp OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End Time stamp for this interval. If this time is later than the current time,
|
|
then the data for this bucket is currently being collected."
|
|
::= { feedPtpPmEntry 1 }
|
|
|
|
|
|
feedPtpPmSampleDuration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fifteenMinutes(1),
|
|
day(2)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The duration of this sample."
|
|
::= { feedPtpPmEntry 2 }
|
|
|
|
|
|
feedPtpPmValidity OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Flag indicating if data was valid for the entire interval"
|
|
::= { feedPtpPmEntry 3 }
|
|
|
|
feedPtpPmInputVoltageMin OBJECT-TYPE
|
|
SYNTAX FloatHundredths
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { feedPtpPmEntry 4 }
|
|
|
|
feedPtpPmInputVoltageMax OBJECT-TYPE
|
|
SYNTAX FloatHundredths
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { feedPtpPmEntry 5 }
|
|
|
|
feedPtpPmInputVoltageAve OBJECT-TYPE
|
|
SYNTAX FloatHundredths
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { feedPtpPmEntry 6 }
|
|
|
|
feedPtpPmInputCurrentMin OBJECT-TYPE
|
|
SYNTAX FloatHundredths
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { feedPtpPmEntry 7 }
|
|
|
|
feedPtpPmInputCurrentMax OBJECT-TYPE
|
|
SYNTAX FloatHundredths
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { feedPtpPmEntry 8 }
|
|
|
|
feedPtpPmInputCurrentAve OBJECT-TYPE
|
|
SYNTAX FloatHundredths
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { feedPtpPmEntry 9 }
|
|
|
|
feedPtpPmRealTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FeedPtpPmRealEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of FeedPtpPmReal entries. Each entry is uniquely identified by the value of ifIndex."
|
|
::= { feedPtpPmMIB 1 }
|
|
|
|
feedPtpPmRealEntry OBJECT-TYPE
|
|
SYNTAX FeedPtpPmRealEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A feedPtp entry containing real-time performance information pertaining to Infinera
|
|
feedPtp interfaces. This table is a subclass of IfCommon."
|
|
INDEX { ifIndex }
|
|
::= { feedPtpPmRealTable 1 }
|
|
|
|
|
|
FeedPtpPmRealEntry ::= SEQUENCE {
|
|
feedPtpPmRealInputVoltage FloatHundredths,
|
|
feedPtpPmRealInputCurrent FloatHundredths
|
|
}
|
|
|
|
feedPtpPmRealInputVoltage OBJECT-TYPE
|
|
SYNTAX FloatHundredths
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { feedPtpPmRealEntry 1 }
|
|
|
|
feedPtpPmRealInputCurrent OBJECT-TYPE
|
|
SYNTAX FloatHundredths
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { feedPtpPmRealEntry 2 }
|
|
|
|
|
|
-- Conformance Statements
|
|
feedPtpPmConformance OBJECT IDENTIFIER ::= { feedPtpPmMIB 3 }
|
|
feedPtpPmCompliances OBJECT IDENTIFIER ::= { feedPtpPmConformance 1 }
|
|
feedPtpPmGroups OBJECT IDENTIFIER ::= { feedPtpPmConformance 2 }
|
|
|
|
feedPtpPmCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the requirements for conformance to the feedPtp-MIB"
|
|
MODULE
|
|
MANDATORY-GROUPS { feedPtpPmGroup }
|
|
::= { feedPtpPmCompliances 1 }
|
|
|
|
feedPtpPmRealCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the requirements for conformance to the FeedPtpPmReal-MIB"
|
|
MODULE
|
|
MANDATORY-GROUPS { feedPtpPmRealGroup }
|
|
::= { feedPtpPmCompliances 2 }
|
|
|
|
feedPtpPmGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
feedPtpPmValidity,
|
|
feedPtpPmInputVoltageMin,
|
|
feedPtpPmInputVoltageMax,
|
|
feedPtpPmInputVoltageAve,
|
|
feedPtpPmInputCurrentMin,
|
|
feedPtpPmInputCurrentMax,
|
|
feedPtpPmInputCurrentAve
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
" A collection of objects for reading the historical performance of the feedPtp."
|
|
::= { feedPtpPmGroups 1 }
|
|
|
|
feedPtpPmRealGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
feedPtpPmRealInputVoltage,
|
|
feedPtpPmRealInputCurrent
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
" A collection of objects for reading the real-time performance of the feedPtp."
|
|
::= { feedPtpPmGroups 2 }
|
|
|
|
END
|
|
|
|
|