-- INFINERA-ENTITY-OMM-MIB
|
|
--
|
|
-- October 2008, Sharfuddin Syed / Narendra Gupta
|
|
--
|
|
--
|
|
-- Copyright (c) 2008-2012 by Infinera Inc.
|
|
-- All rights reserved.
|
|
-- ****************************************************************
|
|
|
|
INFINERA-ENTITY-OMM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI
|
|
OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF
|
|
RowStatus, TruthValue, DisplayString FROM SNMPv2-TC
|
|
entLPPhysicalIndex FROM ENTITY-MIB
|
|
equipment FROM INFINERA-REG-MIB
|
|
InfnEqptType FROM INFINERA-TC-MIB;
|
|
|
|
ommMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200810200000Z"
|
|
ORGANIZATION
|
|
"INFINERA"
|
|
CONTACT-INFO
|
|
"Infinera
|
|
169 Java Drive
|
|
Sunnyvale, CA - 94089
|
|
|
|
Contact : Technical Support
|
|
Email : support@infinera.com
|
|
Phone : 1-877-INF-5288"
|
|
DESCRIPTION
|
|
"This MIB is modeling for OMM equipment table."
|
|
|
|
::= { equipment 10 }
|
|
|
|
ommConformance OBJECT IDENTIFIER ::= { ommMIB 3 }
|
|
ommCompliances OBJECT IDENTIFIER ::= { ommConformance 1 }
|
|
ommGroups OBJECT IDENTIFIER ::= { ommConformance 2 }
|
|
|
|
ommTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OmmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains all OMM modules that are currently present in a network element.
|
|
"
|
|
::= { ommMIB 1 }
|
|
|
|
ommEntry OBJECT-TYPE
|
|
SYNTAX OmmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in the OMM table. Each row in the table is identified with a unique entPhysicalIndexID.
|
|
"
|
|
INDEX { entLPPhysicalIndex }
|
|
::= { ommTable 1 }
|
|
|
|
OmmEntry ::= SEQUENCE {
|
|
ommMoId DisplayString,
|
|
ommProvType InfnEqptType,
|
|
ommRedundancyStatus INTEGER,
|
|
ommBrandingFault TruthValue,
|
|
ommRowStatus RowStatus
|
|
}
|
|
|
|
ommMoId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object identifier."
|
|
::= { ommEntry 1 }
|
|
|
|
ommProvType OBJECT-TYPE
|
|
SYNTAX InfnEqptType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The configured OMM type."
|
|
::= { ommEntry 2 }
|
|
|
|
ommRedundancyStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
single (2),
|
|
active (3),
|
|
standby (4),
|
|
makeStandbyInProgress (5),
|
|
oos (6),
|
|
lock (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the OMM is active or standby."
|
|
::= { ommEntry 3 }
|
|
|
|
ommBrandingFault OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates OMM branding faults."
|
|
::= { ommEntry 4 }
|
|
|
|
ommRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The row status of this OMM entry.
|
|
Because rows in this table are indexed by entPhysicalIndex, to create a new row one must
|
|
choose a value of entPhysicalIndex that is not already in use.
|
|
|
|
A side-effect of the creation of a row in this table is the creation of a corresponding
|
|
row in the eqptTable and the entPhysicalTable.
|
|
|
|
The status may not be set to active if the ommMoId and ommProvEqptType are not set to valid values.
|
|
|
|
This row may only be deleted if it was a pre-provisioned row and the hardware is not present.
|
|
|
|
If this row is deleted, the associated row in the Eqpt Table and entPhysicalTable will be
|
|
deleted by the agent."
|
|
::= { ommEntry 5 }
|
|
|
|
ommCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
MODULE
|
|
MANDATORY-GROUPS { ommGroup }
|
|
::= { ommCompliances 1 }
|
|
|
|
ommGroup OBJECT-GROUP
|
|
OBJECTS { ommBrandingFault,
|
|
ommMoId,
|
|
ommProvType,
|
|
ommRedundancyStatus,
|
|
ommRowStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ommGroups 1 }
|
|
END
|
|
|