-- EKINOPS-pmoailhc.TXT: MIB
--
--MIB Part Number:3MI00209AABE
--MIB Version:1
--
-- Copyright (c) 2016 by Ekinops
-- All rights reserved.
--
-- *****************************************************************
EKINOPS-PmOailhc-MIB DEFINITIONS ::= BEGIN
IMPORTS
ekinops,
EkiState,
EkiOnOff,
EkiMode,
EkiProtocol,
EkiApiState,
EkiSynchroMode,
EkiMeasureType
FROM EKINOPS-MIB
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Unsigned32,
Integer32,
Counter32,
IpAddress
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
DisplayString
FROM SNMPv2-TC;
modulepmoailhc MODULE-IDENTITY
LAST-UPDATED "201605230000Z"
ORGANIZATION "Ekinops"
CONTACT-INFO
"Ekinops
3, rue Blaise Pascal
F-22300 Lannion / FRANCE
Tel : +33 (0)2 96 05 00 30
Fax : +33 (0)2 96 48 62 39
E-mail: support@ekinops.net"
DESCRIPTION
"Creation"
REVISION "201209100000Z"
DESCRIPTION
"Initial Version."
REVISION "201209100000Z"
DESCRIPTION
"Creation"
REVISION "201302080000Z"
DESCRIPTION
"Ext Pump alarms"
REVISION "201307020000Z"
DESCRIPTION
"Constant Gain function"
REVISION "201309160000Z"
DESCRIPTION
"Help change"
REVISION "201312020000Z"
DESCRIPTION
"External Pump Fail Insertion"
REVISION "201403260000Z"
DESCRIPTION
"Probcause,AlarmType - NMS completion"
REVISION "201412100000Z"
DESCRIPTION
"Labels cosmetic updates"
REVISION "201605230000Z"
DESCRIPTION
"New AlarmType synthesisAlarm (12)"
::= { ekinops 55 }
--- *****************************************************
--- LEAF LEVEL 2
--- *****************************************************
pmoailhcalarms OBJECT IDENTIFIER ::= { modulepmoailhc 2 }
pmoailhcAlmOther OBJECT IDENTIFIER ::= { pmoailhcalarms 1 }
pmoailhcAlmOtherNurg OBJECT IDENTIFIER ::= { pmoailhcAlmOther 1 }
pmoailhcAlmOtherUrg OBJECT IDENTIFIER ::= { pmoailhcAlmOther 2 }
pmoailhcAlmOtherCrit OBJECT IDENTIFIER ::= { pmoailhcAlmOther 3 }
pmoailhcAlmClient OBJECT IDENTIFIER ::= { pmoailhcalarms 2 }
pmoailhcAlmClientNurg OBJECT IDENTIFIER ::= { pmoailhcAlmClient 1 }
pmoailhcAlmClientUrg OBJECT IDENTIFIER ::= { pmoailhcAlmClient 2 }
pmoailhcAlmClientCrit OBJECT IDENTIFIER ::= { pmoailhcAlmClient 3 }
pmoailhcAlmLine OBJECT IDENTIFIER ::= { pmoailhcalarms 3 }
pmoailhcAlmLineNurg OBJECT IDENTIFIER ::= { pmoailhcAlmLine 1 }
pmoailhcAlmLineUrg OBJECT IDENTIFIER ::= { pmoailhcAlmLine 2 }
pmoailhcAlmLineCrit OBJECT IDENTIFIER ::= { pmoailhcAlmLine 3 }
pmoailhcmeasures OBJECT IDENTIFIER ::= { modulepmoailhc 3 }
pmoailhcMesrOther OBJECT IDENTIFIER ::= { pmoailhcmeasures 1 }
pmoailhcMesrClient OBJECT IDENTIFIER ::= { pmoailhcmeasures 2 }
pmoailhcMesrLine OBJECT IDENTIFIER ::= { pmoailhcmeasures 3 }
pmoailhccontrolsWrite OBJECT IDENTIFIER ::= { modulepmoailhc 6 }
pmoailhcCtrlOther OBJECT IDENTIFIER ::= { pmoailhccontrolsWrite 1 }
pmoailhcCtrlClient OBJECT IDENTIFIER ::= { pmoailhccontrolsWrite 2 }
pmoailhcCtrlLine OBJECT IDENTIFIER ::= { pmoailhccontrolsWrite 3 }
pmoailhcri OBJECT IDENTIFIER ::= { modulepmoailhc 7 }
pmoailhcConfig OBJECT IDENTIFIER ::= { modulepmoailhc 9 }
pmoailhctraps OBJECT IDENTIFIER ::= { modulepmoailhc 10 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- TEXTUAL-CONVENTION
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
PmoailhcpreampMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different modes on OA preamp"
SYNTAX INTEGER {
oailhcpreampdefaultmode(0),
oailhcpreampconstantcurrentmode(1),
oailhcpreampconstantpowermode(2)
oailhcpreampconstantgainmode(3)
oailhcpreamppoutpinmode(4)
oailhcpreampmanualmode(5)
oailhcpreampfeedforwardmode(6)
oailhcpreamptransientsupmode(7)
}
PmoailhcboosterMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different modes on OA booster"
SYNTAX INTEGER {
oailhcboosterdefaultmode(0),
oailhcboosterconstantcurrentmode(1),
oailhcboosterconstantpowermode(2)
oailhcboosterconstantgainmode(3)
oailhcboosterpoutpinmode(4)
oailhcboostermanualmode(5)
oailhcboosterfeedforwardmode(6)
oailhcboostertransientsupmode(7)
}
PmoailhcaprMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different modes on APR"
SYNTAX INTEGER {
oailhcaproffmode(0),
oailhcaprsemiautomode(1),
oailhcaprautomode(2)
oailhcaprlossforwardingmode(3)
oailhcaprrepeatmode(4)
}
PmoailhcPreampGainAdjMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different modes on Gain"
SYNTAX INTEGER {
oailhcpreampgainadjmanualmode(0),
oailhcpreampgainadjsemiautomode(1),
oailhcpreampgainadjautomode(2)
}
PmoailhcBoosterGainAdjMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different modes on Gain"
SYNTAX INTEGER {
oailhcboostergainadjmanualmode(0),
oailhcboostergainadjsemiautomode(1),
oailhcboostergainadjautomode(2)
}
PmoailhcPreampCstGainAdjMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different modes when constant Gain"
SYNTAX INTEGER {
oailhcpreampcstgainadjsemiautomode(1),
oailhcpreampcstgainadjautomode(2)
}
PmoailhcBoosterCstGainAdjMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different modes when constant Gain"
SYNTAX INTEGER {
oailhcboostercstgainadjsemiautomode(1),
oailhcboostercstgainadjautomode(2)
}
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- REMOTE INVENTORY
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
pmoailhcRinvReloadInventory OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reload the inventory: This OID triggers an
inventory reload."
::= { pmoailhcri 2 }
pmoailhcRinvModulePlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module platform description: This OID contains the
description of the Module."
::= { pmoailhcri 3 }
pmoailhcRinvSwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SW platform description: This OID contains the
description of the Software platform."
::= { pmoailhcri 4 }
pmoailhcRinvSwFoa OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical device driver description: This OID contains
the description of the driver of the optical devices
(Booster and Pre-Amp)"
::= { pmoailhcri 5 }
pmoailhcRinvInLine1Table OBJECT-TYPE
SYNTAX SEQUENCE OF PmoailhcRinvInLine1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of the InLine1s on the selected module"
::= { pmoailhcri 6 }
pmoailhcRinvInLine1Entry OBJECT-TYPE
SYNTAX PmoailhcRinvInLine1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for the InLine1s table"
INDEX { pmoailhcRinvInLine1Index }
::= { pmoailhcRinvInLine1Table 1 }
PmoailhcRinvInLine1Entry::=
SEQUENCE {
pmoailhcRinvInLine1Index
Integer32,
pmoailhcRinvInLine1
DisplayString
}
pmoailhcRinvInLine1Index OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for InLine1 table"
::= { pmoailhcRinvInLine1Entry 1 }
pmoailhcRinvInLine1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Inventory for the InLine1: This OID contains the inventory for the InLine1"
::= { pmoailhcRinvInLine1Entry 2 }
pmoailhcRinvInLine2Table OBJECT-TYPE
SYNTAX SEQUENCE OF PmoailhcRinvInLine2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of the InLine2 on the selected module"
::= { pmoailhcri 7 }
pmoailhcRinvInLine2Entry OBJECT-TYPE
SYNTAX PmoailhcRinvInLine2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for the InLine2 table"
INDEX { pmoailhcRinvInLine2Index }
::= { pmoailhcRinvInLine2Table 1 }
PmoailhcRinvInLine2Entry::=
SEQUENCE {
pmoailhcRinvInLine2Index
Integer32,
pmoailhcRinvInLine2
DisplayString
}
pmoailhcRinvInLine2Index OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for InLine2 table"
::= { pmoailhcRinvInLine2Entry 1 }
pmoailhcRinvInLine2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Inventory for the InLine2: This OID contains the inventory for the InLine2"
::= { pmoailhcRinvInLine2Entry 2 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- ALARMS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the synthAlm0 article
--- *****************************************************
pmoailhcAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmoailhcAlmOtherCrit 0 }
pmoailhcAlmDefFuseB OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse B Fail :This OID indicates
that the fuse of the power input
B is in fail condition <Help>
Status of the Fuse B <Condtype>
DEF_FUSE_B <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoailhcAlmsynthAlm0 16 }
pmoailhcAlmDefFuseA OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse A Fail :This OID indicates
that the fuse of the power input
A is in fail condition <Help>
Status of the Fuse A <Condtype>
DEF_FUSE_A <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoailhcAlmsynthAlm0 15 }
pmoailhcAlmExtPump2NotLocked OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
External Pump2 Not Detected :This
OID indicates that the second external
pump is not detected by the amplifier
module <Help> This alarm indicates
if the second external pump is
detected by the amplifier module
<Condtype> EXT_PUMP2_NOT_LOCKED
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmsynthAlm0 13 }
pmoailhcAlmExtPump1NotLocked OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
External Pump1 Not Detected :This
OID indicates that the first external
pump is not detected by the amplifier
module <Help> This alarm indicates
if the first external pump is detected
by the amplifier module <Condtype>
EXT_PUMP1_NOT_LOCKED <Probcause>
pumpFailure (39) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoailhcAlmsynthAlm0 12 }
pmoailhcAlmDwEdfaInitNotCompl OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Not Initialized :This OID
indicates that the initialisation
of the IL2 is not completed <Help>
This status indicates if the IL2
has been correctly initialized
<Condtype> DW_EDFA_INIT_NOT_COMPL
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmoailhcAlmsynthAlm0 11 }
pmoailhcAlmUpEdfaInitNotCompl OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Not Initialized :This OID
indicates that the initialisation
of the IL1 is not completed <Help>
This status indicates if the IL1
has been correctly initialized
<Condtype> UP_EDFA_INIT_NOT_COMPL
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmoailhcAlmsynthAlm0 10 }
pmoailhcAlmModGlobFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Failure :This OID is set
on detection of a failure originating
from the PM <Condtype> MOD_GLOB_FAIL
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoailhcAlmsynthAlm0 9 }
pmoailhcAlmAprOn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Automatic Power Reduction :This
OID indicates that the APR algorithm
has been operated and the output
of the lasers are shutdown <Help>
The APR algorithm has been completed
<Condtype> APR_ON <Probcause>
other (1) <Alarmtype> other (1)
<Polarity> (2)
"
::= { pmoailhcAlmsynthAlm0 2 }
pmoailhcAlmMaintenanceMode OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Maintenance Mode :This OID indicates
that the PM is in maintenance mode
<Help> This status indiates if
the module is currently in maintenance
mode <Condtype> MAINTENANCE_MODE
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmoailhcAlmsynthAlm0 1 }
--- *****************************************************
--- LEAF for the synthAlm2 article
--- *****************************************************
pmoailhcAlmsynthAlm2 OBJECT IDENTIFIER ::= { pmoailhcAlmOtherNurg 2 }
pmoailhcAlmConfTableLoad OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
PM Configuration Load :This OID
is at 1 during the loading of
configuration tables in the modules
RAM. <Condtype> CONF_TABLE_LOAD
<Probcause> bandwidthReduced(4)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pmoailhcAlmsynthAlm2 3 }
pmoailhcAlmInvUpload OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Inventory Upload :This OID is
at 1 during the uploading of PM
inventory information. <Condtype>
INV_UPLOAD <Probcause> bandwidthReduced(4)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pmoailhcAlmsynthAlm2 2 }
pmoailhcAlmConfTableSave OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
PM Configuration Save :This OID
is at 1 during the saving of a
new configuration table in the
module Flash memory. <Condtype>
CONF_TABLE_SAVE <Probcause> bandwidthReduced(4)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pmoailhcAlmsynthAlm2 1 }
--- *****************************************************
--- LEAF for the synthAlm7 article
--- *****************************************************
pmoailhcAlmsynthAlm7 OBJECT IDENTIFIER ::= { pmoailhcAlmLineCrit 7 }
pmoailhcAlmLineExtPumpFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 External Pump Fail :This OID
indicates that the external pump
linked to the IL1 is in fail condition
<Help> This alarm indicates
if the external pump linked to
the IL1 is in fail condition <Condtype>
LINE_EXT_PUMP_FAIL <Probcause>
pumpFailure (39) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoailhcAlmsynthAlm7 13 }
pmoailhcAlmLineFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Port Failure :This OID indicates
a failure on the line port <Condtype>
LINE_FAIL <Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoailhcAlmsynthAlm7 12 }
pmoailhcAlmLineDdmAlm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Alarm On Line Optical Module DDM
:This OID indicates an alarm is
present coming out of Line optical
interface DDM <Condtype> LINE_DDM_ALM
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoailhcAlmsynthAlm7 10 }
pmoailhcAlmLineDdmWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Warning On Line Optical Module
DDM :This OID indicates a warning
is present coming out of Line optical
interface DDM <Condtype> LINE_DDM_WARNING
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoailhcAlmsynthAlm7 9 }
pmoailhcAlmLineTxOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Optical Output Shutdown :This
OID indicates the IL1 optical output
power is on <Help> This status
indicates if the IL1 laser pump
is ON or OFF <Condtype> LINE_TX_OFF
<Probcause> other (1) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmsynthAlm7 5 }
pmoailhcAlmLineHwFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Port HW Failure :This OID
indicates a failure on line port,
most probably caused by a HW issue
<Condtype> LINE_HW_FAIL <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmoailhcAlmsynthAlm7 4 }
--- *****************************************************
--- LEAF for the synthAlm8 article
--- *****************************************************
pmoailhcAlmsynthAlm8 OBJECT IDENTIFIER ::= { pmoailhcAlmClientCrit 8 }
pmoailhcAlmClientExtPumpFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 External Pump Fail :This OID
indicates that first external pump
linked to the IL2 is in fail condition
<Help> This alarm indicates
if the external pump linked to
the IL2 is in fail condition <Condtype>
CLIENT_EXT_PUMP_FAIL <Probcause>
pumpFailure (39) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoailhcAlmsynthAlm8 13 }
pmoailhcAlmClientFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Port Failure :This OID
indicates a failure on the Client
port <Condtype> CLIENT_FAIL <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmoailhcAlmsynthAlm8 12 }
pmoailhcAlmClientDdmAlm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Alarm On Client Optical Module
DDM :This OID indicates an alarm
is present coming out of Client
optical interface DDM <Condtype>
CLIENT_DDM_ALM <Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoailhcAlmsynthAlm8 10 }
pmoailhcAlmClientDdmWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Warning On Client Optical Module
DDM :This OID indicates a warning
is present coming out of Client
optical interface DDM <Condtype>
CLIENT_DDM_WARNING <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmoailhcAlmsynthAlm8 9 }
pmoailhcAlmClientTxOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Optical Output Shutdown :This
OID indicates the IL2 optical output
power is on <Help> This status
indicates if the IL2 laser pump
transceiver laser is ON or OFF
<Condtype> CLIENT_TX_OFF <Probcause>
other (1) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoailhcAlmsynthAlm8 5 }
pmoailhcAlmClientHwFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Port HW Failure :This OID
indicates a failure on Client port,
most probably caused by a HW issue
<Condtype> CLIENT_HW_FAIL <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmoailhcAlmsynthAlm8 4 }
--- *****************************************************
--- LEAF for the clientEdfaAlarms1 article
--- *****************************************************
pmoailhcAlmclientEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoailhcAlmClientUrg 32 }
pmoailhcAlmClientBiasHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Bias High Alarm :This OID
indicates that the Bias is higher
than the alarm theshold of the
IL2 Optical Module <Help> This
alarm indicates if the IL2 bias
is too high <Condtype> CLIENT_BIAS_HIGH_ALARM
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmclientEdfaAlarms1 8 }
pmoailhcAlmClientBiasLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Bias Low Alarm :This OID indicates
that the Bias is lower than the
alarm theshold of the IL2 Optical
Module <Help> This alarm indicates
if the IL2 bias is too low <Condtype>
CLIENT_BIAS_LOW_ALARM <Probcause>
pumpFailure (39) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoailhcAlmclientEdfaAlarms1 7 }
pmoailhcAlmClientOutputPwrHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Tx Pwr High Alarm :This OID
indicates that the Transmit Power
is higher than the alarm theshold
of the IL2 Optical Module <Help>
This alarm indicates if the IL2
tx power is too high <Condtype>
CLIENT_OUTPUT_PWR_HIGH_ALARM <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmclientEdfaAlarms1 6 }
pmoailhcAlmClientOutputPwrLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Tx Pwr Low Alarm :This OID
indicates that the Transmit Power
is lower than the alarm theshold
of the IL2 Optical Module <Help>
This alarm indicates if the IL2
tx power is too low <Condtype>
CLIENT_OUTPUT_PWR_LOW_ALARM <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmclientEdfaAlarms1 5 }
pmoailhcAlmClientInputPwrHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Rx Pwr High Alarm :This OID
indicates that the Receive Power
is higher than the alarm theshold
of the IL1 Optical Module <Help>
This alarm indicates if the IL1
rx power is too high <Condtype>
CLIENT_INPUT_PWR_HIGH_ALARM <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmclientEdfaAlarms1 4 }
pmoailhcAlmClientInputPwrLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Rx Pwr Low Alarm :This OID
indicates that the Receive Power
is lower than the alarm theshold
of the IL1 Optical Module <Help>
This alarm indicates if the IL1
rx power is too low <Condtype>
CLIENT_INPUT_PWR_LOW_ALARM <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmclientEdfaAlarms1 3 }
pmoailhcAlmClientGainHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Gain High Alarm :This OID
indicates that the Gain is higher
than the alarm threshold of the
IL2 Module <Help> This alarm
indicates if the IL2 gain is too
high <Condtype> CLIENT_GAIN_HIGH_ALARM
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoailhcAlmclientEdfaAlarms1 2 }
pmoailhcAlmClientGainLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Gain Low Alarm :This OID indicates
that the Gain is lower than the
alarm theshold of the IL2 Module
<Help> This alarm indicates if
the IL2 gain is too low <Condtype>
CLIENT_GAIN_LOW_ALARM <Probcause>
performanceDegraded (35) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmclientEdfaAlarms1 1 }
--- *****************************************************
--- LEAF for the clientEdfaWarnings article
--- *****************************************************
pmoailhcAlmclientEdfaWarnings OBJECT IDENTIFIER ::= { pmoailhcAlmClientNurg 33 }
pmoailhcAlmClientBiasHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Bias High Warning :This OID
indicates that the Bias is higher
than the Warning theshold of the
IL2 Optical Module <Help> This
warning indicates if the IL2 bias
is too high <Condtype> CLIENT_BIAS_HIGH_WARNING
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmclientEdfaWarnings 8 }
pmoailhcAlmClientBiasLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Bias Low Warning :This OID
indicates that the Bias is lower
than the Warning theshold of the
IL2 Optical Module <Help> This
warning indicates if the IL2 bias
is too low <Condtype> CLIENT_BIAS_LOW_WARNING
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmclientEdfaWarnings 7 }
pmoailhcAlmClientOutputPwrHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Tx Pwr High Warning :This
OID indicates that the Transmit
Power is higher than the Warning
theshold of the IL2 Optical Module
<Help> This warning indicates
if the IL2 tx power is too high
<Condtype> CLIENT_OUTPUT_PWR_HIGH_WARNING
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoailhcAlmclientEdfaWarnings 6 }
pmoailhcAlmClientOutputPwrLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Tx Pwr Low Warning :This OID
indicates that the Transmit Power
is lower than the Warning theshold
of the IL2 Optical Module <Help>
This warning indicates if the
IL2 tx power is too low <Condtype>
CLIENT_OUTPUT_PWR_LOW_WARNING <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmclientEdfaWarnings 5 }
pmoailhcAlmClientInputPwrHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Rx Pwr High Warning :This
OID indicates that the Receive
Power is higher than the Warning
theshold of the IL1 Optical Module
<Help> This warning indicates
if the IL1 rx power is too high
<Condtype> CLIENT_INPUT_PWR_HIGH_WARNING
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoailhcAlmclientEdfaWarnings 4 }
pmoailhcAlmClientInputPwrLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Rx Pwr Low Warning :This OID
indicates that the Receive Power
is lower than the Warning theshold
of the IL1 Optical Module <Help>
This warning indicates if the
IL1 rx power is too low <Condtype>
CLIENT_INPUT_PWR_LOW_WARNING <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmclientEdfaWarnings 3 }
pmoailhcAlmClientGainHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Gain High Warning :This OID
indicates that the Gain is higher
than the Warning threshold of the
IL2 Module <Help> This alarm
indicates if the IL2 gain is too
high <Condtype> CLIENT_GAIN_HIGH_WARNING
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoailhcAlmclientEdfaWarnings 2 }
pmoailhcAlmClientGainLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Gain Low Warning :This OID
indicates that the Gain is lower
than the Warning theshold of the
IL2 Module <Help> This alarm
indicates if the IL2 gain is too
low <Condtype> CLIENT_GAIN_LOW_WARNING
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoailhcAlmclientEdfaWarnings 1 }
--- *****************************************************
--- LEAF for the clientEdfaAlarms2 article
--- *****************************************************
pmoailhcAlmclientEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoailhcAlmClientCrit 35 }
pmoailhcAlmClientExtPumpEdfaLowCurrent OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Pump Low Current :This OID
indicates that the EDFA pump current
of IL2 is too low because of the
external pump high power<Help>
This alarm (only active when
there is at least on external
pump) indicates that the EDFA
pump current of the IL2 is too
low because of the external pump
high power. <Condtype> CLIENT_EXT_PUMP_EDFA_LOW_CURRENT
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity>
(2)
"
::= { pmoailhcAlmclientEdfaAlarms2 5 }
pmoailhcAlmClientEdfaLos OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Loss Of Signal :This OID indicates
a Loss of Signal on the IL1 Optical
Module <Help> This alarm indicates
if an optical signal is detected
on the IL1 input <Condtype> CLIENT_EDFA_LOS
<Probcause> receiveFailure (41)
<Alarmtype> physicalViolation (9)
<Polarity> (2)
"
::= { pmoailhcAlmclientEdfaAlarms2 4 }
pmoailhcAlmClientEdfaLaserFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Pump Laser Fail :This OID
indicates a Transmit Laser Fail
on the IL2 Optical Module <Help>
This alarm indicates if the laser
of the IL2 is in fail condition
<Condtype> CLIENT_EDFA_LASER_FAIL
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmclientEdfaAlarms2 3 }
pmoailhcAlmClientEdfaTecFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 TEC Fail :This OID indicates
that the TEC is in fail condition
on the IL2 Optical Module <Help>
This alarm indicates if the TEC
of the IL2 is in fail condition
<Condtype> CLIENT_EDFA_TEC_FAIL
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmclientEdfaAlarms2 2 }
pmoailhcAlmClientEdfaNr OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Optical Module Not Ready :This
OID indicates that the IL2 Optical
Module is not ready <Help> This
status indicates if the IL2 has
been correctly initialized <Condtype>
CLIENT_EDFA_NR <Probcause> equipmentMalfunction
(16) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoailhcAlmclientEdfaAlarms2 1 }
--- *****************************************************
--- LEAF for the lineEdfaAlarms1 article
--- *****************************************************
pmoailhcAlmlineEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoailhcAlmLineUrg 40 }
pmoailhcAlmLineBiasHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Bias High Alarm :This OID
indicates that the Bias is higher
than the alarm theshold of the
IL1 Optical Module <Help> This
alarm indicates if the IL1 bias
is too high <Condtype> LINE_BIAS_HIGH_ALARM
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmlineEdfaAlarms1 8 }
pmoailhcAlmLineBiasLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Bias Low Alarm :This OID indicates
that the Bias is lower than the
alarm theshold of the IL1 Optical
Module <Help> This alarm indicates
if the IL1 bias is too low <Condtype>
LINE_BIAS_LOW_ALARM <Probcause>
pumpFailure (39) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoailhcAlmlineEdfaAlarms1 7 }
pmoailhcAlmLineOutputPwrHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Tx Pwr High Alarm :This OID
indicates that the Transmit Power
is higher than the alarm theshold
of the IL1 Optical Module <Help>
This alarm indicates if the IL1
tx power is too high <Condtype>
LINE_OUTPUT_PWR_HIGH_ALARM <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmlineEdfaAlarms1 6 }
pmoailhcAlmLineOutputPwrLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Tx Pwr Low Alarm :This OID
indicates that the Transmit Power
is lower than the alarm theshold
of the IL1 Optical Module <Help>
This alarm indicates if the IL1
tx power is too low <Condtype>
LINE_OUTPUT_PWR_LOW_ALARM <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmlineEdfaAlarms1 5 }
pmoailhcAlmLineInputPwrHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Rx Pwr High Alarm :This OID
indicates that the Receive Power
is higher than the alarm theshold
of the IL2 Optical Module <Help>
This alarm indicates if the IL2
rx power is too high <Condtype>
LINE_INPUT_PWR_HIGH_ALARM <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmlineEdfaAlarms1 4 }
pmoailhcAlmLineInputPwrLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Rx Pwr Low Alarm :This OID
indicates that the Receive Power
is lower than the alarm theshold
of the IL2 Optical Module <Help>
This alarm indicates if the IL2
rx power is too low <Condtype>
LINE_INPUT_PWR_LOW_ALARM <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmlineEdfaAlarms1 3 }
pmoailhcAlmLineGainHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Gain High Alarm :This OID
indicates that the Gain is higher
than the alarm threshold of the
IL1 Module <Help> This alarm
indicates if the IL1 gain is too
high <Condtype> LINE_GAIN_HIGH_ALARM
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoailhcAlmlineEdfaAlarms1 2 }
pmoailhcAlmLineGainLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Gain Low Alarm :This OID indicates
that the Gain is lower than the
alarm theshold of the IL1 Module
<Help> This alarm indicates if
the IL1 gain is too low <Condtype>
LINE_GAIN_LOW_ALARM <Probcause>
performanceDegraded (35) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmlineEdfaAlarms1 1 }
--- *****************************************************
--- LEAF for the lineEdfaWarnings article
--- *****************************************************
pmoailhcAlmlineEdfaWarnings OBJECT IDENTIFIER ::= { pmoailhcAlmLineNurg 41 }
pmoailhcAlmLineBiasHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Bias High Warning :This OID
indicates that the Bias is higher
than the Warning theshold of the
IL1 Optical Module <Help> This
warning indicates if the IL1 bias
is too high <Condtype> LINE_BIAS_HIGH_WARNING
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmlineEdfaWarnings 8 }
pmoailhcAlmLineBiasLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Bias Low Warning :This OID
indicates that the Bias is lower
than the Warning theshold of the
IL1 Optical Module <Help> This
warning indicates if the IL1 bias
is too low <Condtype> LINE_BIAS_LOW_WARNING
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmlineEdfaWarnings 7 }
pmoailhcAlmLineOutputPwrHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Tx Pwr High Warning :This
OID indicates that the Transmit
Power is higher than the Warning
theshold of the IL1 Optical Module
<Help> This warning indicates
if the IL1 tx power is too high
<Condtype> LINE_OUTPUT_PWR_HIGH_WARNING
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoailhcAlmlineEdfaWarnings 6 }
pmoailhcAlmLineOutputPwrLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Tx Pwr Low Warning :This OID
indicates that the Transmit Power
is lower than the Warning theshold
of the IL1 Optical Module <Help>
This warning indicates if the
IL1 tx power is too low <Condtype>
LINE_OUTPUT_PWR_LOW_WARNING <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmlineEdfaWarnings 5 }
pmoailhcAlmLineInputPwrHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Rx Pwr High Warning :This
OID indicates that the Receive
Power is higher than the Warning
theshold of the IL2 Optical Module
<Help> This warning indicates
if the IL2 rx power is too high
<Condtype> LINE_INPUT_PWR_HIGH_WARNING
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoailhcAlmlineEdfaWarnings 4 }
pmoailhcAlmLineInputPwrLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Rx Pwr Low Warning :This OID
indicates that the Receive Power
is lower than the Warning theshold
of the IL2 Optical Module <Help>
This warning indicates if the
IL2 rx power is too low <Condtype>
LINE_INPUT_PWR_LOW_WARNING <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmlineEdfaWarnings 3 }
pmoailhcAlmLineGainHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Gain High Warning :This OID
indicates that the Gain is higher
than the Warning threshold of the
IL1 Module <Help> This alarm
indicates if the IL1 gain is too
high <Condtype> LINE_GAIN_HIGH_WARNING
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoailhcAlmlineEdfaWarnings 2 }
pmoailhcAlmLineGainLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Gain Low Warning :This OID
indicates that the Gain is lower
than the Warning theshold of the
IL1 Module <Help> This alarm
indicates if the IL1 gain is too
low <Condtype> LINE_GAIN_LOW_WARNING
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoailhcAlmlineEdfaWarnings 1 }
--- *****************************************************
--- LEAF for the lineEdfaAlarms2 article
--- *****************************************************
pmoailhcAlmlineEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoailhcAlmLineCrit 43 }
pmoailhcAlmLineExtPumpEdfaLowCurrent OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Pump Low Current :This OID
indicates that the EDFA pump current
of IL1 is too low because of the
external pump high power<Help>
This alarm (only active when
there is at least on external
pump) indicates that the EDFA
pump current of the IL1 is too
low because of the external pump
high power. <Condtype> LINE_EXT_PUMP_EDFA_LOW_CURRENT
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity>
(2)
"
::= { pmoailhcAlmlineEdfaAlarms2 5 }
pmoailhcAlmLineEdfaLos OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Loss Of Signal :This OID indicates
a Loss of Signal on the IL2 Optical
Module <Help> This alarm indicates
if an optical signal is detected
on the IL2 input <Condtype> LINE_EDFA_LOS
<Probcause> receiveFailure (41)
<Alarmtype> physicalViolation (9)
<Polarity> (2)
"
::= { pmoailhcAlmlineEdfaAlarms2 4 }
pmoailhcAlmLineEdfaLaserFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Pump Laser Fail :This OID
indicates a Transmit Laser Fail
on the IL1 Optical Module <Help>
This alarm indicates if the laser
of the IL1 is in fail condition
<Condtype> LINE_EDFA_LASER_FAIL
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmlineEdfaAlarms2 3 }
pmoailhcAlmLineEdfaTecFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 TEC Fail :This OID indicates
that the TEC is in fail condition
on the IL1 Optical Module <Help>
This alarm indicates if the TEC
of the IL1 is in fail condition
<Condtype> LINE_EDFA_TEC_FAIL <Probcause>
pumpFailure (39) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoailhcAlmlineEdfaAlarms2 2 }
pmoailhcAlmLineEdfaNr OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Optical Module Not Ready :This
OID indicates that the IL1 Optical
Module is not ready <Help> This
status indicates if the IL1 has
been correctly initialized <Condtype>
LINE_EDFA_NR <Probcause> equipmentMalfunction
(16) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoailhcAlmlineEdfaAlarms2 1 }
--- *****************************************************
--- LEAF for the foaAlarms article
--- *****************************************************
pmoailhcAlmfoaAlarms OBJECT IDENTIFIER ::= { pmoailhcAlmOtherUrg 74 }
pmoailhcAlmTempHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Temperature High Alarm :This OID
indicates that the PM temperature
is higher than the alarm threshold
<Condtype> TEMP_HIGH_ALARM <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmfoaAlarms 8 }
pmoailhcAlmTermpLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Temperature Low Alarm :This OID
indicates that the PM temperature
if lower than the alarm threshold
<Condtype> TERMP_LOW_ALARM <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmfoaAlarms 7 }
--- *****************************************************
--- LEAF for the foaWarnings article
--- *****************************************************
pmoailhcAlmfoaWarnings OBJECT IDENTIFIER ::= { pmoailhcAlmOtherNurg 75 }
pmoailhcAlmTempHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Temperature High Warning :This
OID indicates that the PM temperature
if higher than the Warning threshold
<Condtype> TEMP_HIGH_WARNING <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmfoaWarnings 8 }
pmoailhcAlmTermpLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Temperature Low Warning :This
OID indicates that the PM temperature
if lower than the Warning threshold
<Condtype> TERMP_LOW_WARNING <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoailhcAlmfoaWarnings 7 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONTROLS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the synth0 article
--- *****************************************************
pmoailhcCtrlsynth0 OBJECT IDENTIFIER ::= { pmoailhcCtrlOther 0 }
pmoailhcCtrlConfClear OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Clear Configuration Tables :This
bit clears the configuration tables
from configuration in the flash.
<Help> This control restores
the default configuration of the
module
"
::= { pmoailhcCtrlsynth0 13 }
pmoailhcCtrlConfFlash OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Write Configuration Tables :This
bit saves the current configuration
of the module as configuration
in the flash. <Help> This control
saves the customer configuration
on the module
"
::= { pmoailhcCtrlsynth0 9 }
pmoailhcCtrlConfLoad OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Load Configuration Tables :When
set this enables loading from flash
configuration1 into the module.
"
::= { pmoailhcCtrlsynth0 1 }
--- *****************************************************
--- LEAF for the swMgnt article
--- *****************************************************
pmoailhcCtrlswMgnt OBJECT IDENTIFIER ::= { pmoailhcCtrlOther 5 }
pmoailhcCtrlWarmReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
PM Warm Reset :This OID, when
set, causes a warm reset of the
Software. This reset is not traffic
affecting, and the configuration
of the Sofwtare remains unchanged.
<Help> This control initiates
a warm reset of the module.
"
::= { pmoailhcCtrlswMgnt 3 }
pmoailhcCtrlColdReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
PM Cold Reset :This OID, when
set, causes a cold reset of the
Software. This reset is traffic
affecting, and the configuration
of Software is reloaded on start-up.
<Help> This control initiates
a cold reset of the module.
"
::= { pmoailhcCtrlswMgnt 2 }
--- *****************************************************
--- LEAF for the clientEdfaLaserOff article
--- *****************************************************
pmoailhcCtrlclientEdfaLaserOff OBJECT IDENTIFIER ::= { pmoailhcCtrlClient 32 }
pmoailhcCtrlClientEdfaLaserOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
IL2 Optical Module Laser Off :This
OID switches OFF the laser of the
IL2li Optical Module <Help> This
control defines the laser state
of the IL2
"
::= { pmoailhcCtrlclientEdfaLaserOff 1 }
--- *****************************************************
--- LEAF for the clientGainCstMonitorValue article
--- *****************************************************
pmoailhcCtrlclientGainCstMonitorValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
IL2 Fiber Aging Period :This OID
sets the value of the monitoring
period to detect a fiber aging.
(Unit = s) This value sets the
monitoring period to detect a
fiber aging.
"
::= { pmoailhcCtrlClient 34 }
--- *****************************************************
--- LEAF for the clientGainCstPoutValue article
--- *****************************************************
pmoailhcCtrlclientGainCstPoutValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
IL2 Ref Pout :This OID sets the
value of the reference output power
used to compensate the fiber aging
(active only in constant gain
mode) (AV=(Gain/0,005) + 32768)
(Unit = dBm) <Help> This value
defines the reference output power
used to compensate the fiber aging
"
::= { pmoailhcCtrlClient 35 }
--- *****************************************************
--- LEAF for the clientGainSettingValue article
--- *****************************************************
pmoailhcCtrlclientGainSettingValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
IL2 Gain Target :This OID sets
the value of the nominal gain of
the IL2 Module (active only in
constant output power mode) (AV=(Gain/0,005)
+ 32768) (Unit = dB) <Help> This
control sets the value of the nominal
gain of the IL2 Module (active
only in constant output power
mode)
"
::= { pmoailhcCtrlClient 36 }
--- *****************************************************
--- LEAF for the clientGainProcessing article
--- *****************************************************
pmoailhcCtrlclientGainProcessing OBJECT IDENTIFIER ::= { pmoailhcCtrlClient 37 }
pmoailhcCtrlClientGainProc OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
IL2 Gain Adjustment :<Help> This
control initiates the automatic
nominal gain adjustment on the
IL2 Module<Help> This control
initiates the automatic nominal
gain adjustment on the IL2 Module
"
::= { pmoailhcCtrlclientGainProcessing 1 }
--- *****************************************************
--- LEAF for the clientGainCstFiberAgingMarginValue article
--- *****************************************************
pmoailhcCtrlclientGainCstFiberAgingMarginValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
IL2 Aging Threshold :This OID
sets the threshold to consider
the power drop as a fiber aging.
(active only in constant gain mode)
(AV=(Gain/0,005) + 32768) (Unit
= dB) <Help> This value defines
the threshold to consider the power
drop as a fiber aging.
"
::= { pmoailhcCtrlClient 38 }
--- *****************************************************
--- LEAF for the clientGainCstAdddropMarginValue article
--- *****************************************************
pmoailhcCtrlclientGainCstAdddropMarginValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
IL2 AddDrop Threshold :This OID
sets the threshold to not consider
the power drop as a fiber aging.
(active only in constant gain
mode) (AV=(Gain/0,005) + 32768)
(Unit = dB) <Help> This value defines
the threshold to not consider the
power drop as a fiber aging.
"
::= { pmoailhcCtrlClient 39 }
--- *****************************************************
--- LEAF for the lineEdfaLaserOff article
--- *****************************************************
pmoailhcCtrllineEdfaLaserOff OBJECT IDENTIFIER ::= { pmoailhcCtrlLine 40 }
pmoailhcCtrlLineEdfaLaserOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
IL1 Optical Module Laser Off :This
OID switches OFF the laser of the
IL1 Optical Module <Help> This
control defines the laser state
of the IL1
"
::= { pmoailhcCtrllineEdfaLaserOff 1 }
--- *****************************************************
--- LEAF for the lineGainCstMonitorValue article
--- *****************************************************
pmoailhcCtrllineGainCstMonitorValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
IL1 Fiber Aging Period :This OID
sets the value of the monitoring
period to detect a fiber aging.
(Unit = s) This value sets the
monitoring period to detect a
fiber aging.
"
::= { pmoailhcCtrlLine 42 }
--- *****************************************************
--- LEAF for the lineGainCstPoutValue article
--- *****************************************************
pmoailhcCtrllineGainCstPoutValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
IL1 Ref Pout :This OID sets the
value of the reference output power
used to compensate the fiber aging
(active only in constant gain
mode) (AV=(Gain/0,005) + 32768)
(Unit = dBm) <Help> This value
defines the reference output power
used to compensate the fiber aging
"
::= { pmoailhcCtrlLine 43 }
--- *****************************************************
--- LEAF for the lineGainSettingValue article
--- *****************************************************
pmoailhcCtrllineGainSettingValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
IL1 Gain Target :This OID sets
the value of the nominal gain of
the IL1 Module (active only in
constant output power mode) (AV=(Gain/0,005)
+ 32768) (Unit = dB) <Help> This
control sets the value of the nominal
gain of the IL1 Module (active
only in constant output power
mode)
"
::= { pmoailhcCtrlLine 44 }
--- *****************************************************
--- LEAF for the lineGainProcessing article
--- *****************************************************
pmoailhcCtrllineGainProcessing OBJECT IDENTIFIER ::= { pmoailhcCtrlLine 45 }
pmoailhcCtrlLineGainProc OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
IL1 Gain Adjustment :This OID
initiates the automatic nominal
gain adjustment on the IL1 Module<Help>
This control initiates the automatic
nominal gain adjustment on the
IL1 Module
"
::= { pmoailhcCtrllineGainProcessing 1 }
--- *****************************************************
--- LEAF for the lineGainCstFiberAgingMarginValue article
--- *****************************************************
pmoailhcCtrllineGainCstFiberAgingMarginValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
IL1 Aging Threshold :This OID
sets the threshold to consider
the power drop as a fiber aging.
(active only in constant gain mode)
(AV=(Gain/0,005) + 32768) (Unit
= dB) <Help> This value defines
the threshold to consider the power
drop as a fiber aging.
"
::= { pmoailhcCtrlLine 46 }
--- *****************************************************
--- LEAF for the lineGainCstAdddropMarginValue article
--- *****************************************************
pmoailhcCtrllineGainCstAdddropMarginValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
IL1 AddDrop Threshold :This OID
sets the threshold to not consider
the power drop as a fiber aging.
(active only in constant gain
mode) (AV=(Gain/0,005) + 32768)
(Unit = dB) <Help> This value defines
the threshold to not consider the
power drop as a fiber aging.
"
::= { pmoailhcCtrlLine 47 }
--- *****************************************************
--- LEAF for the ledTest article
--- *****************************************************
pmoailhcCtrlledTest OBJECT IDENTIFIER ::= { pmoailhcCtrlOther 73 }
pmoailhcCtrlLedOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Leds Off :This OID switches off
all the Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to OFF
"
::= { pmoailhcCtrlledTest 3 }
pmoailhcCtrlRedLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Red Leds Test :This OID switches
on all the red Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to red
"
::= { pmoailhcCtrlledTest 2 }
pmoailhcCtrlGreenLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Green Leds Test :This OID switches
on all the green Leds as a test
feature. <Help> This control
initiates a test leds turning
all the LEDs to green
"
::= { pmoailhcCtrlledTest 1 }
--- *****************************************************
--- LEAF for the maintMode article
--- *****************************************************
pmoailhcCtrlmaintMode OBJECT IDENTIFIER ::= { pmoailhcCtrlOther 75 }
pmoailhcCtrlMaintenance OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
PM Maintenance Mode :This OID
sets the PM in maintenance mode
<Help> This control enables the
maintenance mode of the module
"
::= { pmoailhcCtrlmaintMode 1 }
--- *****************************************************
--- LEAF for the aprRestart article
--- *****************************************************
pmoailhcCtrlaprRestart OBJECT IDENTIFIER ::= { pmoailhcCtrlOther 76 }
pmoailhcCtrlAprManualRestart OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
APR Manual Restart :This OID initiates
the Restart mechanism to retrieve
from the APR state.<Help> This
control initiates the Restart
mechanism to retrieve from the
APR state.
"
::= { pmoailhcCtrlaprRestart 1 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- MEASURES
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the clientEdfaBiasMeas article
--- *****************************************************
pmoailhcMesrclientEdfaBiasMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Pump Laser Current :This OID
gives the pump laser current of
the IL2 Optical Module (Current
=AV/100) (Unit = mA) <Help> This
measure gives the bias of the IL2
pump laser
"
::= { pmoailhcMesrClient 32 }
--- *****************************************************
--- LEAF for the clientEdfaTxpwrMeas article
--- *****************************************************
pmoailhcMesrclientEdfaTxpwrMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Tx Power :This OID gives the
transmit power value of the IL2
Optical Module (Power =(AV-32768)*0,005)
(Unit = dBm) <Help> This measure
gives the Tx optical power of the
IL2
"
::= { pmoailhcMesrClient 33 }
--- *****************************************************
--- LEAF for the clientEdfaRxpwrMeas article
--- *****************************************************
pmoailhcMesrclientEdfaRxpwrMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Rx Power :This OID gives the
receive power value of the IL1
Optical Module (Power =(AV-32768)*0,005)
(Unit = dBm) <Help> This measure
gives the Rx optical power of the
IL1
"
::= { pmoailhcMesrClient 34 }
--- *****************************************************
--- LEAF for the clientEdfaGainMeas article
--- *****************************************************
pmoailhcMesrclientEdfaGainMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Gain Target :This OID gives
the gain value of the IL2 Module
(Gain =(AV-32768)*0,005) (Unit
= dB) <Help> This information
gives the target gain of the amplifier
for optimal performance
"
::= { pmoailhcMesrClient 35 }
--- *****************************************************
--- LEAF for the clientCorrectedGain article
--- *****************************************************
pmoailhcMesrclientCorrectedGain OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Gain :This OID gives the gain
value of the IL2 Module corrected
by the ASE compensation mechanism
(Gain =(AV-32768)*0,005) (Unit
= dB) <Help> This measure gives
the effective gain of the amplifier
"
::= { pmoailhcMesrClient 38 }
--- *****************************************************
--- LEAF for the lineEdfaBiasMeas article
--- *****************************************************
pmoailhcMesrlineEdfaBiasMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Pump Laser Current :This OID
gives the pump laser current of
the IL1 Optical Module (Current
=AV/100) (Unit = mA) <Help> This
measure gives the bias of the IL1
pump laser
"
::= { pmoailhcMesrLine 40 }
--- *****************************************************
--- LEAF for the lineEdfaTxpwrMeas article
--- *****************************************************
pmoailhcMesrlineEdfaTxpwrMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Tx Power :This OID gives the
transmit power value of the IL1
Optical Module (Power =(AV-32768)*0,005)
(Unit = dBm) <Help> This measure
gives the Tx optical power of the
IL1
"
::= { pmoailhcMesrLine 41 }
--- *****************************************************
--- LEAF for the lineEdfaRxpwrMeas article
--- *****************************************************
pmoailhcMesrlineEdfaRxpwrMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL2 Rx Power :This OID gives the
receive power value of the IL2
Optical Module (Power =(AV-32768)*0,005)
(Unit = dBm) <Help> This measure
gives the Rx optical power of the
IL2
"
::= { pmoailhcMesrLine 42 }
--- *****************************************************
--- LEAF for the lineEdfaGainMeas article
--- *****************************************************
pmoailhcMesrlineEdfaGainMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Gain Target :This OID gives
the gain value of the IL1 Module
(Gain =(AV-32768)*0,005) (Unit
= dB) <Help> This information
gives the target gain of the amplifier
for optimal performance
"
::= { pmoailhcMesrLine 43 }
--- *****************************************************
--- LEAF for the lineCorrectedGain article
--- *****************************************************
pmoailhcMesrlineCorrectedGain OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
IL1 Gain :This OID gives the gain
value of the IL1 Module corrected
by the ASE compensation mechanism
(Gain =(AV-32768)*0,005) (Unit
= dB) <Help> This measure gives
the effective gain of the amplifier
"
::= { pmoailhcMesrLine 46 }
--- *****************************************************
--- LEAF for the tempMeas article
--- *****************************************************
pmoailhcMesrtempMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Temperature :This OID gives
the temperature of the PM (Temperature
=AV/256) (Unit = C) <Help> This
measure gives the temperature of
the module
"
::= { pmoailhcMesrOther 72 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONFIG
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the table Group noValue
--- *****************************************************
pmoailhcCfgNoValue OBJECT IDENTIFIER ::= { pmoailhcConfig 1 }
--- *****************************************************
--- LEAF for the table 2111
--- *****************************************************
pmoailhctableclientStartup OBJECT IDENTIFIER ::= { pmoailhcCfgNoValue 1 }
pmoailhcCfgclientEdfaLaserCtrl OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Client Laser
:This OID configures the default
initialisation settings on the
client laser.
"
::= { pmoailhctableclientStartup 2 }
pmoailhcCfgclientEdfaLaserMode OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Client mode
:This OID configures the default
mode on the client amplifier.
"
::= { pmoailhctableclientStartup 3 }
pmoailhcCfgclientGainValue OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Client Gain
:This OID configures the default
gain on the client amplifier.
"
::= { pmoailhctableclientStartup 4 }
pmoailhcCfgclientTiltValue OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Client Tilt
:This OID configures the default
tilt on the client amplifier.
"
::= { pmoailhctableclientStartup 5 }
pmoailhcCfgclientMsaLoss OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Client MSA
:This OID configures the default
MSA value on the client amplifier.
"
::= { pmoailhctableclientStartup 6 }
pmoailhcCfgclientOutputPowerValue OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Client Output
power :This OID configures the
default Output power value on
the client amplifier.
"
::= { pmoailhctableclientStartup 7 }
pmoailhcCfgclientAseCompensation OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Client ASE
:This OID configures the default
ASE compensation value on the client
amplifier.
"
::= { pmoailhctableclientStartup 8 }
--- *****************************************************
--- LEAF for the table Group lineStartUp
--- *****************************************************
pmoailhcCfgLineStartUp OBJECT IDENTIFIER ::= { pmoailhcConfig 2 }
--- *****************************************************
--- LEAF for the table 2191
--- *****************************************************
pmoailhctablelineStartup OBJECT IDENTIFIER ::= { pmoailhcCfgLineStartUp 1 }
pmoailhcCfglineEdfaLaserCtrl OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Line Laser
:This OID configures the default
initialisation settings on the
line laser.
"
::= { pmoailhctablelineStartup 2 }
pmoailhcCfglineEdfaLaserMode OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Line mode
:This OID configures the default
mode on the line amplifier.
"
::= { pmoailhctablelineStartup 3 }
pmoailhcCfglineGainValue OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Line Gain
:This OID configures the default
gain on the line amplifier.
"
::= { pmoailhctablelineStartup 4 }
pmoailhcCfglineTiltValue OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Line Tilt
:This OID configures the default
tilt on the line amplifier.
"
::= { pmoailhctablelineStartup 5 }
pmoailhcCfglineMsaLoss OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Line MSA :This
OID configures the default MSA
value on the line amplifier.
"
::= { pmoailhctablelineStartup 6 }
pmoailhcCfglineOutputPowerValue OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Line Output
power :This OID configures the
default Output power value on
the line amplifier.
"
::= { pmoailhctablelineStartup 7 }
pmoailhcCfglineAseCompensation OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Line ASE :This
OID configures the default ASE
compensation value on the line
amplifier.
"
::= { pmoailhctablelineStartup 8 }
pmoailhcCfgaprMode OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default setting on module :This
OID configures the default mode
on the APR
"
::= { pmoailhctablelineStartup 11 }
--- *****************************************************
--- LEAF for the table Group labels
--- *****************************************************
pmoailhcCfgLabels OBJECT IDENTIFIER ::= { pmoailhcConfig 3 }
--- *****************************************************
--- LEAF for the table NO_VALUE
--- *****************************************************
pmoailhcCfgLabelclientTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmoailhcCfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pmoailhcCfgLabels 1 }
pmoailhcCfgLabelclientEntry OBJECT-TYPE
SYNTAX PmoailhcCfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pmoailhcCfgLabelclientIndex }
::= { pmoailhcCfgLabelclientTable 1 }
PmoailhcCfgLabelclientEntry ::=
SEQUENCE {
pmoailhcCfgLabelclientIndex
INTEGER,
pmoailhcCfgLabelclientPortn
DisplayString
}
pmoailhcCfgLabelclientIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelclient
table
"
::= { pmoailhcCfgLabelclientEntry 1 }
pmoailhcCfgLabelclientPortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the Ports :These registers
configures the default initialisation
settings of the labels of the ports.
"
::= { pmoailhcCfgLabelclientEntry 3 }
--- *****************************************************
--- LEAF for the table NO_VALUE
--- *****************************************************
pmoailhcCfgLabellineTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmoailhcCfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pmoailhcCfgLabels 2 }
pmoailhcCfgLabellineEntry OBJECT-TYPE
SYNTAX PmoailhcCfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pmoailhcCfgLabellineIndex }
::= { pmoailhcCfgLabellineTable 1 }
PmoailhcCfgLabellineEntry ::=
SEQUENCE {
pmoailhcCfgLabellineIndex
INTEGER,
pmoailhcCfgLabellinePortn
DisplayString
}
pmoailhcCfgLabellineIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelline
table
"
::= { pmoailhcCfgLabellineEntry 1 }
pmoailhcCfgLabellinePortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the lines :These registers
configures the default initialisation
settings of the labels of the lines.
"
::= { pmoailhcCfgLabellineEntry 3 }
pmoailhcCfgWriteConfiguration OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Write configuration to module:This OID
writes the complete configuration to the module"
::= { pmoailhcConfig 257 }
--- *****************************************************
--- TRAP OBJECTS
--- *****************************************************
pmoailhctrapBoardNumber OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last module which generates a trap"
::= { pmoailhctraps 4 }
--- *****************************************************
--- GLOBAL TRAPS
--- *****************************************************
pmoailhcLineTrapNotUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoailhcAlmLineDdmWarning, pmoailhctrapBoardNumber}
STATUS current
--&FILTNAME "PMOAILHC Line Not Urgent ON"
--&ACTIONS { log, minor }
--&MATCH { pmoailhcAlmLineDdmWarning "on", pmoailhctrapBoardNumber "$2"}
--&MESG "DDM Warning appears on Pre-Amp input or Booster Output of PMOAILHC in slot $2 ($A)"
DESCRIPTION "Not urgent Line default is activated"
::= { pmoailhctraps 30 }
pmoailhcLineTrapNotUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoailhcAlmLineDdmWarning, pmoailhctrapBoardNumber}
STATUS current
--&FILTNAME "PMOAILHC Line Not Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS {"PMOAILHC Line Not Urgent ON"}
--&MATCH { pmoailhcAlmLineDdmWarning "on", pmoailhctrapBoardNumber "$2"}
--&MESG "DDM Warning disappears on Pre-Amp input or Booster Output of PMOAILHC in slot $2 ($A)"
DESCRIPTION "Not urgent Line default disappeared"
::= { pmoailhctraps 31 }
pmoailhcLineTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoailhcAlmLineDdmAlm, pmoailhctrapBoardNumber}
STATUS current
--&FILTNAME "PMOAILHC Line Urgent ON"
--&ACTIONS { log, major }
--&MATCH { pmoailhcAlmLineDdmAlm "on", pmoailhctrapBoardNumber "$2"}
--&MESG "DDM Alarm appears on Pre-Amp input or Booster Output of PMOAILHC in slot $2 ($A)"
DESCRIPTION "Urgent Line default is activated"
::= { pmoailhctraps 32 }
pmoailhcLineTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoailhcAlmLineDdmAlm, pmoailhctrapBoardNumber}
STATUS current
--&FILTNAME "PMOAILHC Line Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS {"PMOAILHC Line Urgent ON"}
--&MATCH { pmoailhcAlmLineDdmAlm "on", pmoailhctrapBoardNumber "$2"}
--&MESG "DDM Alarm disappears on Pre-Amp input or Booster Output of PMOAILHC in slot $2 ($A)"
DESCRIPTION "Urgent Line default disappeared"
::= { pmoailhctraps 33 }
pmoailhcLineTrapCritGoesOn NOTIFICATION-TYPE
OBJECTS {pmoailhcAlmLineFail, pmoailhcAlmLineHwFail, pmoailhctrapBoardNumber}
STATUS current
--&FILTNAME "PMOAILHC Line Fail ON"
--&ACTIONS { log, critical }
--&MATCH { pmoailhcAlmLineFail "on", pmoailhcAlmLineHwFail "*", pmoailhctrapBoardNumber "$3"}
--&MESG "Critical Alarm appears on Pre-Amp input or Booster Output of PMOAILHC in slot $3 ($A)"
--&FILTNAME "PMOAILHC Line HW Fail ON (Hidden)"
--&ACTIONS { info }
--&MATCH { pmoailhcAlmLineFail "*", pmoailhcAlmLineHwFail "on", pmoailhctrapBoardNumber "$3"}
--&MESG "Critical Alarm appears on Pre-Amp input or Booster Output of PMOAILHC in slot $3 ($A)"
DESCRIPTION "Critical Line default is activated"
::= { pmoailhctraps 34 }
pmoailhcLineTrapCritGoesOff NOTIFICATION-TYPE
OBJECTS {pmoailhcAlmLineFail, pmoailhcAlmLineHwFail, pmoailhctrapBoardNumber}
STATUS current
--&FILTNAME "PMOAILHC Line Fail OFF"
--&ACTIONS { log, normal }
--&CLEARS {"PMOAILHC Line Fail ON"}
--&MATCH { pmoailhcAlmLineFail "on", pmoailhcAlmLineHwFail "*", pmoailhctrapBoardNumber "$3"}
--&MESG "Critical Alarm disappears on Pre-Amp input or Booster Output of PMOAILHC in slot $3 ($A)"
--&FILTNAME "PMOAILHC Line HW Fail OFF (Hidden)"
--&ACTIONS { info }
--&MATCH { pmoailhcAlmLineFail "*", pmoailhcAlmLineHwFail "on", pmoailhctrapBoardNumber "$3"}
--&MESG "Critical Alarm disappears on Pre-Amp input or Booster Output of PMOAILHC in slot $3 ($A)"
DESCRIPTION "Critical Line default disappeared"
::= { pmoailhctraps 35 }
--- *****************************************************
--- PORTS TRAPS
--- *****************************************************
pmoailhcClientTrapNotUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoailhcAlmClientDdmWarning, pmoailhctrapBoardNumber}
STATUS current
--&FILTNAME "PMOAILHC Client Not Urgent ON"
--&ACTIONS { log, minor }
--&MATCH { pmoailhcAlmClientDdmWarning "on", pmoailhctrapBoardNumber "$2"}
--&MESG "DDM Warning appears on Booster input or Pre-Amp Output of PMOAILHC in slot $2 ($A)"
DESCRIPTION "Not urgent client default is activated"
::= { pmoailhctraps 40 }
pmoailhcClientTrapNotUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoailhcAlmClientDdmWarning, pmoailhctrapBoardNumber}
STATUS current
--&FILTNAME "PMOAILHC Client Not Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS {"PMOAILHC Client Not Urgent ON"}
--&MATCH { pmoailhcAlmClientDdmWarning "on", pmoailhctrapBoardNumber "$2"}
--&MESG "DDM Warning disappears on Booster input or Pre-Amp Output of PMOAILHC in slot $2 ($A)"
DESCRIPTION "Not urgent client default disappeared"
::= { pmoailhctraps 41 }
pmoailhcClientTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoailhcAlmClientDdmAlm, pmoailhctrapBoardNumber}
STATUS current
--&FILTNAME "PMOAILHC Client Urgent ON"
--&ACTIONS { log, major }
--&MATCH { pmoailhcAlmClientDdmAlm "on", pmoailhctrapBoardNumber "$2"}
--&MESG "DDM Alarm appears on Booster input or Pre-Amp Output of PMOAILHC in slot $2 ($A)"
DESCRIPTION "Urgent client default is activated"
::= { pmoailhctraps 42 }
pmoailhcClientTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoailhcAlmClientDdmAlm, pmoailhctrapBoardNumber}
STATUS current
--&FILTNAME "PMOAILHC Client Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS {"PMOAILHC Client Urgent ON"}
--&MATCH { pmoailhcAlmClientDdmAlm "on", pmoailhctrapBoardNumber "$2"}
--&MESG "DDM Alarm disappears on Booster input or Pre-Amp Output of PMOAILHC in slot $2 ($A)"
DESCRIPTION "Urgent client default disappeared"
::= { pmoailhctraps 43 }
pmoailhcClientTrapCritGoesOn NOTIFICATION-TYPE
OBJECTS {pmoailhcAlmClientFail, pmoailhcAlmClientHwFail, pmoailhctrapBoardNumber}
STATUS current
--&FILTNAME "PMOAILHC Client Fail ON"
--&ACTIONS { log, critical }
--&MATCH { pmoailhcAlmClientFail "on", pmoailhcAlmClientHwFail "*", pmoailhctrapBoardNumber "$3"}
--&MESG "Critical Alarm appears on Booster input or Pre-Amp Output of PMOAILHC in slot $3 ($A)"
--&FILTNAME "PMOAILHC Client HW Fail ON (Hidden)"
--&ACTIONS { info }
--&MATCH { pmoailhcAlmClientFail "*", pmoailhcAlmClientHwFail "on", pmoailhctrapBoardNumber "$3"}
--&MESG "Critical Alarm appears on Booster input or Pre-Amp Output of PMOAILHC in slot $3 ($A)"
DESCRIPTION "Critical client default is activated"
::= { pmoailhctraps 44 }
pmoailhcClientTrapCritGoesOff NOTIFICATION-TYPE
OBJECTS {pmoailhcAlmClientFail, pmoailhcAlmClientHwFail, pmoailhctrapBoardNumber}
STATUS current
--&FILTNAME "PMOAILHC Client Fail OFF"
--&ACTIONS { log, normal }
--&CLEARS {"PMOAILHC Client Fail ON"}
--&MATCH { pmoailhcAlmClientFail "on", pmoailhcAlmClientHwFail "*", pmoailhctrapBoardNumber "$3"}
--&MESG "Critical Alarm disappears on Booster input or Pre-Amp Output of PMOAILHC in slot $3 ($A)"
--&FILTNAME "PMOAILHC Client HW Fail OFF (Hidden)"
--&ACTIONS { info }
--&MATCH { pmoailhcAlmClientFail "*", pmoailhcAlmClientHwFail "on", pmoailhctrapBoardNumber "$3"}
--&MESG "Critical Alarm disappears on Booster input or Pre-Amp Output of PMOAILHC in slot $3 ($A)"
DESCRIPTION "Critical client default disappeared"
::= { pmoailhctraps 45 }
--- *****************************************************
--- HW TRAPS
--- *****************************************************
pmoailhcPowerTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoailhcAlmDefFuseB, pmoailhcAlmDefFuseA , pmoailhctrapBoardNumber}
STATUS current
--&FILTNAME "PMOAILHC Fuse A Fail ON"
--&ACTIONS { log, major }
--&MATCH { pmoailhcAlmDefFuseB "*", pmoailhcAlmDefFuseA "on", pmoailhctrapBoardNumber "$3"}
--&MESG "Power Input A Fail on PMOAILHC in Slot $3 ($A)"
--&FILTNAME "PMOAILHC Fuse B Fail ON"
--&ACTIONS { log, major }
--&MATCH { pmoailhcAlmDefFuseB "on", pmoailhcAlmDefFuseA "*", pmoailhctrapBoardNumber "$3"}
--&MESG "Power Input B Fail on PMOAILHC in Slot $3 ($A)"
DESCRIPTION "Urgent power supply default is activated"
::= { pmoailhctraps 50 }
pmoailhcPowerTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoailhcAlmDefFuseB, pmoailhcAlmDefFuseA , pmoailhctrapBoardNumber}
STATUS current
--&FILTNAME "PMOAILHC Fuse A&B Fail OFF"
--&ACTIONS { log, normal}
--&CLEARS { "PMOAILHC Fuse A Fail ON", "PMOAILHC Fuse B Fail ON" }
--&MATCH { pmoailhcAlmDefFuseB "on", pmoailhcAlmDefFuseA "on", pmoailhctrapBoardNumber "$3"}
--&MESG "Power Inputs A and B Present on PMOAILHC in Slot $3 ($A)"
DESCRIPTION "Urgent power supply default disappeared"
::= { pmoailhctraps 51 }
END