Observium_CE/mibs/ekinops/EKINOPS-Pm801RR-MIB

4005 lines
105 KiB
Plaintext
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

-- *****************************************************************
-- EKINOPS-Pm801RR.TXT: MIB
--
--MIB Part Number:3MI00101ACAD
--MIB Version:02
--
-- Copyright (c) 2016 by Ekinops
-- All rights reserved.
--
-- *****************************************************************
EKINOPS-Pm801RR-MIB DEFINITIONS ::= BEGIN
IMPORTS
ekinops,
EkiState,
EkiOnOff,
EkiMode,
EkiProtocol,
EkiApiState,
EkiSynchroMode,
EkiMeasureType
FROM EKINOPS-MIB
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Unsigned32,
Integer32,
Counter32,
IpAddress
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
DisplayString
FROM SNMPv2-TC;
modulePm801RR MODULE-IDENTITY
LAST-UPDATED "201606070000Z"
ORGANIZATION "Ekinops"
CONTACT-INFO
"Ekinops
3, rue Blaise Pascal
F-22300 Lannion / FRANCE
Tel : +33 (0)2 96 05 00 30
Fax : +33 (0)2 96 48 62 39
E-mail: support@ekinops.net"
DESCRIPTION
"MIB for the Ekinops Pm801RR hardware."
REVISION "201008260000Z"
DESCRIPTION
"Initial Version."
REVISION "201008260000Z"
DESCRIPTION
"Creation"
REVISION "201011030000Z"
DESCRIPTION
"Formula in comments, Event on XFP init"
REVISION "201207040000Z"
DESCRIPTION
"Minor cosmetic updates"
REVISION "201403250000Z"
DESCRIPTION
"Probcause,AlarmType - NMS completion"
REVISION "201412090000Z"
DESCRIPTION
"Labels cosmetic updates"
REVISION "201605230000Z"
DESCRIPTION
"New AlarmType synthesisAlarm (12)"
REVISION "201606070000Z"
DESCRIPTION
"Capabilities objects of Table 5"
::= { ekinops 48 }
--- *****************************************************
--- LEAF LEVEL 2
--- *****************************************************
pm801rralarms OBJECT IDENTIFIER ::= { modulePm801RR 2 }
pm801rrAlmOther OBJECT IDENTIFIER ::= { pm801rralarms 1 }
pm801rrAlmOtherNurg OBJECT IDENTIFIER ::= { pm801rrAlmOther 1 }
pm801rrAlmOtherUrg OBJECT IDENTIFIER ::= { pm801rrAlmOther 2 }
pm801rrAlmOtherCrit OBJECT IDENTIFIER ::= { pm801rrAlmOther 3 }
pm801rrAlmClient OBJECT IDENTIFIER ::= { pm801rralarms 2 }
pm801rrAlmClientNurg OBJECT IDENTIFIER ::= { pm801rrAlmClient 1 }
pm801rrAlmClientUrg OBJECT IDENTIFIER ::= { pm801rrAlmClient 2 }
pm801rrAlmClientCrit OBJECT IDENTIFIER ::= { pm801rrAlmClient 3 }
pm801rrAlmLine OBJECT IDENTIFIER ::= { pm801rralarms 3 }
pm801rrAlmLineNurg OBJECT IDENTIFIER ::= { pm801rrAlmLine 1 }
pm801rrAlmLineUrg OBJECT IDENTIFIER ::= { pm801rrAlmLine 2 }
pm801rrAlmLineCrit OBJECT IDENTIFIER ::= { pm801rrAlmLine 3 }
pm801rrmeasures OBJECT IDENTIFIER ::= { modulePm801RR 3 }
pm801rrMesrOther OBJECT IDENTIFIER ::= { pm801rrmeasures 1 }
pm801rrMesrClient OBJECT IDENTIFIER ::= { pm801rrmeasures 2 }
pm801rrMesrLine OBJECT IDENTIFIER ::= { pm801rrmeasures 3 }
pm801rrcontrolsWrite OBJECT IDENTIFIER ::= { modulePm801RR 6 }
pm801rrCtrlOther OBJECT IDENTIFIER ::= { pm801rrcontrolsWrite 1 }
pm801rrCtrlClient OBJECT IDENTIFIER ::= { pm801rrcontrolsWrite 2 }
pm801rrCtrlLine OBJECT IDENTIFIER ::= { pm801rrcontrolsWrite 3 }
pm801rrri OBJECT IDENTIFIER ::= { modulePm801RR 7 }
pm801rrConfig OBJECT IDENTIFIER ::= { modulePm801RR 9 }
pm801rrtraps OBJECT IDENTIFIER ::= { modulePm801RR 10 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- TEXTUAL-CONVENTION
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
Pm801rrBitRate ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "different rates for a client and line ports"
SYNTAX INTEGER {
rateOC192(0),
rate10GBELAN(1),
rate10GBEWAN(2),
rate10GFC(3),
rate10FECG975(4),
rate10FECG709(5)
}
Pm801rrOtxMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different modes on OTX-TLH on client and line ports"
SYNTAX INTEGER {
otx80mode(1),
otx60mode(2),
otxadjustmode(4)
}
Pm801rrOtxGrid ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different grids on OTX-TLH on client and line ports"
SYNTAX INTEGER {
otxgrid200(200),
otxgrid100(100),
otxgrid50(50)
}
Pm801rrAdjustValue ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different values in Adjust mode on OTX-TLH on client and line ports"
SYNTAX INTEGER {
otxadjustvalue0(0),
otxadjustvalue1(1),
otxadjustvalue2(2),
otxadjustvalue3(3),
otxadjustvalue4(4),
otxadjustvalue5(5),
otxadjustvalue6(6),
otxadjustvalue7(7),
otxadjustvalue8(8),
otxadjustvalue9(9),
otxadjustvalue10(10)
}
Pm801rrOtxChannel ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Channel selection on OTX-TLH on client and line ports"
SYNTAX INTEGER
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- REMOTE INVENTORY
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
pm801rrRinvReloadInventory OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reload the inventory: This OID triggers an
inventory reload."
::= { pm801rrri 2 }
pm801rrRinvHwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module platform description: This OID contains the
description of the Module."
::= { pm801rrri 4 }
pm801rrRinvSwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SW platform description: This OID contains the
description of the Software platform."
::= { pm801rrri 5 }
pm801rrRinvClientXFP OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Inventory for the XFP: This OID contains the inventory for the Client XFP"
::= { pm801rrri 6 }
pm801rrRinvLineXFP OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Inventory for the XFP: This OID contains the inventory for the Line XFP"
::= { pm801rrri 7 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- ALARMS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the synthAlm0 article
--- *****************************************************
pm801rrAlmsynthAlm0 OBJECT IDENTIFIER ::= { pm801rrAlmOtherCrit 0 }
pm801rrAlmDefFuseB OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse B Fail :This OID indicates
that the fuse of the power input
B is in fail condition <Help>
Status of the Fuse B <Condtype>
DEF_FUSE_B <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmsynthAlm0 16 }
pm801rrAlmDefFuseA OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse A Fail :This OID indicates
that the fuse of the power input
A is in fail condition <Help>
Status of the Fuse A <Condtype>
DEF_FUSE_A <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmsynthAlm0 15 }
pm801rrAlmModuleGlobFailure OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Failure :This OID is set
on detection of a failure originating
from the PM <Condtype> MODULE_GLOB_FAILURE
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pm801rrAlmsynthAlm0 9 }
--- *****************************************************
--- LEAF for the synthAlm7 article
--- *****************************************************
pm801rrAlmsynthAlm7 OBJECT IDENTIFIER ::= { pm801rrAlmLineCrit 7 }
pm801rrAlmLineVccAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 VCC Alarm :This OID indicates
an overall VCC alarm is set over
the Line 2 XFP <Condtype> LINE_VCC_ALARM
<Probcause> powerProblem (36) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmsynthAlm7 15 }
pm801rrAlmLineVccWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 VCC Warning :This OID indicates
an overall VCC warning is set over
the Line 2 XFP <Condtype> LINE_VCC_WARNING
<Probcause> powerProblem (36) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmsynthAlm7 14 }
pm801rrAlmLineFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Port Failure :This OID
indicates a failure on the Line
2 port <Condtype> LINE_FAIL <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pm801rrAlmsynthAlm7 12 }
pm801rrAlmLineDdmAlm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Alarm On Line 2 Optical Module
DDM :This OID indicates an alarm
is present coming out of Line 2
optical interface DDM <Help>
This alarm indicates if a DDM
Alarm has been detected on the
line 2 transceiver <Condtype> LINE_DDM_ALM
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pm801rrAlmsynthAlm7 10 }
pm801rrAlmLineDdmWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Warning On Line 2 Optical Module
DDM :This OID indicates a warning
is present coming out of Line 2
optical interface DDM <Help>
This alarm indicates if a DDM
Warning has been detected on the
line 2 transceiver <Condtype> LINE_DDM_WARNING
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pm801rrAlmsynthAlm7 9 }
pm801rrAlmLineXfpTxOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Module Laser Shutdown
:This OID indicates the Line 2
optical output power is off <Help>
This status indicates if the line
2 transceiver laser is ON or OFF
<Condtype> LINE_XFP_TX_OFF <Probcause>
other (1) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmsynthAlm7 5 }
pm801rrAlmLineHwFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Port HW Failure :This OID
indicates a failure on Line 2 port,
most probably caused by a HW issue
<Condtype> LINE_HW_FAIL <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pm801rrAlmsynthAlm7 4 }
pm801rrAlmLineInitNotCompl OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Module Ready :This
OID indicates the optical interface
(XFP or OTX) is not operational
<Help> This status indicates
if the line 2 transceiver has
been correctly initialized <Condtype>
LINE_INIT_NOT_COMPL <Probcause>
equipmentMalfunction (16) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
<Event> ObjectCDINV
"
::= { pm801rrAlmsynthAlm7 2 }
pm801rrAlmLineXfpAbsent OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Module Absent :This
OID indicates the Line 2 optical
interface (XFP or OTX) is not present
in the PM <Help> This alarm indicates
if the line 2 transceiver is present.
<Condtype> LINE_XFP_ABSENT <Probcause>
inputOutputDeviceError (24) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
<Event> ObjectCDINV
"
::= { pm801rrAlmsynthAlm7 1 }
--- *****************************************************
--- LEAF for the synthAlm8 article
--- *****************************************************
pm801rrAlmsynthAlm8 OBJECT IDENTIFIER ::= { pm801rrAlmClientCrit 8 }
pm801rrAlmClientVccAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 VCC Alarm :This OID indicates
an overall VCC alarm is set over
the Line 1 XFP <Condtype> CLIENT_VCC_ALARM
<Probcause> powerProblem (36) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmsynthAlm8 15 }
pm801rrAlmClientVccWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1VCC Warning :This OID indicates
an overall VCC warning is set over
the Line 1 XFP <Condtype> CLIENT_VCC_WARNING
<Probcause> powerProblem (36) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmsynthAlm8 14 }
pm801rrAlmClientFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Port Failure :This OID
indicates a failure on the Line
1 port <Condtype> CLIENT_FAIL <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pm801rrAlmsynthAlm8 12 }
pm801rrAlmClientDdmAlm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Alarm On Line 1 Optical Module
DDM :This OID indicates an alarm
is present coming out of Line 1
optical interface DDM <Help>
This alarm indicates if a DDM
Alarm has been detected on the
line 1 transceiver <Condtype> CLIENT_DDM_ALM
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pm801rrAlmsynthAlm8 10 }
pm801rrAlmClientDdmWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Warning On Line 1 Optical Module
DDM :This OID indicates a warning
is present coming out of Line 1
optical interface DDM <Help>
This alarm indicates if a DDM
Warning has been detected on the
line 1 transceiver <Condtype> CLIENT_DDM_WARNING
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pm801rrAlmsynthAlm8 9 }
pm801rrAlmClientXfpTxOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Module Laser Shutdown
:This OID indicates the Line 1
optical output power is off <Help>
This status indicates if the line
1 transceiver laser is ON or OFF
<Condtype> CLIENT_XFP_TX_OFF <Probcause>
other (1) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmsynthAlm8 5 }
pm801rrAlmClientHwFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Port HW Failure :This OID
indicates a failure on Line 1 port,
most probably caused by a HW issue.
<Condtype> CLIENT_HW_FAIL <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pm801rrAlmsynthAlm8 4 }
pm801rrAlmClientInitNotCompl OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Module Ready :This
OID indicates the optical interface
(XFP or OTX) is not operational
<Help> This status indicates
if the line 1 transceiver has
been correctly initialized <Condtype>
CLIENT_INIT_NOT_COMPL <Probcause>
equipmentMalfunction (16) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
<Event> ObjectCDINV
"
::= { pm801rrAlmsynthAlm8 2 }
pm801rrAlmClientXfpAbsent OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Module Absent :This
OID indicates the Line 1 optical
interface (XFP or OTX) is not present
in the PM <Help> This alarm indicates
if the line 1 transceiver is present.
<Condtype> CLIENT_XFP_ABSENT <Probcause>
inputOutputDeviceError (24) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
<Event> ObjectCDINV
"
::= { pm801rrAlmsynthAlm8 1 }
--- *****************************************************
--- LEAF for the clientXfpAlarm1 article
--- *****************************************************
pm801rrAlmclientXfpAlarm1 OBJECT IDENTIFIER ::= { pm801rrAlmClientUrg 16 }
pm801rrAlmClientRxPwrHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Rx Power High :Alarm
indicating that the Line 1 XFP/OTX
received optical power is higher
than the threshold value written
in the Line 1 XFP/OTX EEPROM <Condtype>
CLIENT_RX_PWR_HIGH_ALA <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpAlarm1 16 }
pm801rrAlmClientRxPwrLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Rx Power Low :Alarm
indicating that the Line 1 XFP/OTX
received optical power is lower
than the threshold value written
in the Line 1 XFP/OTX EEPROM <Condtype>
CLIENT_RX_PWR_LOW_ALA <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpAlarm1 15 }
pm801rrAlmClientTempHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Transceiver Temp High :Alarm
indicating that the Line 1 XFP/OTX
temperature is higher than the
threshold value written in the
Line 1 XFP/OTX EEPROM <Condtype>
CLIENT_TEMP_HIGH_ALA <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpAlarm1 8 }
pm801rrAlmClientTempLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Transceiver Temp Low :Alarm
indicating that the Line 1 XFP/OTX
temperature is lower than the threshold
value written in the Line 1 XFP/OTX
EEPROM <Condtype> CLIENT_TEMP_LOW_ALA
<Probcause> temperatureUnacceptable
(51) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpAlarm1 7 }
pm801rrAlmClientTxBiasHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Transceiver Bias High :Alarm
indicating that the Line 1 XFP/OTX
transmitter laser bias current
is higher than the threshold value
written in the Line 1 XFP/OTX EEPROM
<Condtype> CLIENT_TX_BIAS_HIGH_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpAlarm1 4 }
pm801rrAlmClientTxBiasLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Transceiver Bias Low :Alarm
indicating that the Line 1 XFP/OTX
transmitter laser bias current
is lower than the threshold value
written in the Line 1 XFP/OTX EEPROM
<Condtype> CLIENT_TX_BIAS_LOW_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpAlarm1 3 }
pm801rrAlmClientTxPwrHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Tx Power High :Alarm
indicating that the Line 1 XFP/OTX
transmitter transmitter output
power is higher than the threshold
value written in the Line 1 XFP/OTX
EEPROM <Condtype> CLIENT_TX_PWR_HIGH_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpAlarm1 2 }
pm801rrAlmClientTxPwrLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Tx Power Low :Alarm
indicating that the Line 1 XFP/OTX
transmitter transmitter output
power is lower than the threshold
value written in the Line 1 XFP/OTX
EEPROM <Condtype> CLIENT_TX_PWR_LOW_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpAlarm1 1 }
--- *****************************************************
--- LEAF for the clientXfpWarnings article
--- *****************************************************
pm801rrAlmclientXfpWarnings OBJECT IDENTIFIER ::= { pm801rrAlmClientNurg 17 }
pm801rrAlmClientRxPwrHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Rx Power High Warning
:Warning indicating that the Line
1 XFP/OTX received optical power
is higher than the threshold value
written in the Line 1 XFP/OTX EEPROM
<Condtype> CLIENT_RX_PWR_HIGH_WNG
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pm801rrAlmclientXfpWarnings 16 }
pm801rrAlmClientRxPwrLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Rx Power Low Warning
:Warning indicating that the Line
1 XFP/OTX received optical power
is lower than the threshold value
written in the Line 1 XFP/OTX EEPROM
<Condtype> CLIENT_RX_PWR_LOW_WNG
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pm801rrAlmclientXfpWarnings 15 }
pm801rrAlmClientTempHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Transceiver Temp High Warning
:Warning indicating that the Line
1 XFP/OTX temperature is higher
than the threshold value written
in the Line 1 XFP/OTX EEPROM <Condtype>
CLIENT_TEMP_HIGH_WNG <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpWarnings 8 }
pm801rrAlmClientTempLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Transceiver Temp Low Warning
:Warning indicating that the Line
1 XFP/OTX temperature is lower
than the threshold value written
in the Line 1 XFP/OTX EEPROM <Condtype>
CLIENT_TEMP_LOW_WNG <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpWarnings 7 }
pm801rrAlmClientTxBiasHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Transceiver Bias High Warning
:Warning indicating that the Line
1 XFP/OTX transmitter laser bias
current is higher than the threshold
value written in the Line 1 XFP/OTX
EEPROM <Condtype> CLIENT_TX_BIAS_HIGH_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpWarnings 4 }
pm801rrAlmClientTxBiasLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Transceiver Bias Low Warning
:Warning indicating that the Line
1 XFP/OTX transmitter laser bias
current is lower than the threshold
value written in the Line 1 XFP/OTX
EEPROM <Condtype> CLIENT_TX_BIAS_LOW_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpWarnings 3 }
pm801rrAlmClientTxPwrHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Tx Power High Warning
:Warning indicating that the Line
1 XFP/OTX transmitter transmitter
output power is higher than the
threshold value written in the
Line 1 XFP/OTX EEPROM <Condtype>
CLIENT_TX_PWR_HIGH_WNG <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpWarnings 2 }
pm801rrAlmClientTxPwrLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Tx Power Low Warning
:Warning indicating that the Line
1 XFP/OTX transmitter transmitter
output power is lower than the
threshold value written in the
Line 1 XFP/OTX EEPROM <Condtype>
CLIENT_TX_PWR_LOW_WNG <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpWarnings 1 }
--- *****************************************************
--- LEAF for the clientXfpAlarms2 article
--- *****************************************************
pm801rrAlmclientXfpAlarms2 OBJECT IDENTIFIER ::= { pm801rrAlmClientCrit 19 }
pm801rrAlmClientApdSupplyFault OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Rx Photodiode Power Failed
:This OID indicates a failure on
the Line 1 APD power supply <Condtype>
CLIENT_APD_SUPPLY_FAULT <Probcause>
receiverFailure (42) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpAlarms2 16 }
pm801rrAlmClientTecFault OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Tx Temp Regul.
Failed :This OID indicates a failure
on the Line 1 TEC module <Condtype>
CLIENT_TEC_FAULT <Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpAlarms2 15 }
pm801rrAlmClientWavelengthUnlocked OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Tx Wavelength Unlocked
:This OID indicates that the Line
1 wavelength error is exceeding
the manufacturer tolerance <Condtype>
CLIENT_WAVELENGTH_UNLOCKED <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpAlarms2 14 }
pm801rrAlmClientChannelNotAcquired OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 DWDM Channel Not Acquired
:This OID indicates the transceiver
didn't tune the DWDM Channel succesfully.
<Help> This status indicates
the transceiver has not tuned
the DWDM Channel succesfully.
<Condtype> CLIENT_CHANNEL_NOT_ACQUIRED
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpAlarms2 10 }
pm801rrAlmClientTxNr OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Tx Not Ready :This
OID indicates a condition has arisen
leading to invalid data on the
Line 1 transmitting side <Condtype>
CLIENT_TX_NR <Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpAlarms2 8 }
pm801rrAlmClientTxFault OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Tx Failure :This
OID indicates a fault condition
on the Line 1 laser detected by
the safety syste <Condtype> CLIENT_TX_FAULT
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpAlarms2 7 }
pm801rrAlmClientTxCdrNotLocked OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Tx CDR Unlocked
:This OID indicates a loss of lock
on the Line 1 transmitting side
CDR has been detected. <Condtype>
CLIENT_TX_CDR_NOT_LOCKED <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpAlarms2 6 }
pm801rrAlmClientRxNr OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Rx Not Ready :This
OID indicates that a condition
has arisen leading to invalid
data on the Line 1 receiving side.
<Condtype> CLIENT_RX_NR <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpAlarms2 5 }
pm801rrAlmClientRxLos OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Loss Of Optical Signal
:This bit indicates an absence
of signal on the XFP/OTX <Help>
This alarm indicates if an optical
signal is detected on the line
1 transceiver input <Condtype>
CLIENT_RX_LOS <Probcause> receiveFailure
(41) <Alarmtype> physicalViolation
(9) <Polarity> (2)
"
::= { pm801rrAlmclientXfpAlarms2 4 }
pm801rrAlmClientRxCdrNotLocked OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Rx CDR Unlocked
:This OID indicates that a loss
of lock on the Line 1 receiving
side CDR has been detected <Condtype>
CLIENT_RX_CDR_NOT_LOCKED <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmclientXfpAlarms2 3 }
pm801rrAlmClientResetComplete OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Not Used :This bit indicates that
the internal reset process is completed
and the data are available <Condtype>
CLIENT_RESET_COMPLETE <Probcause>
other (1) <Alarmtype> other (1)
<Polarity> (2)
"
::= { pm801rrAlmclientXfpAlarms2 1 }
--- *****************************************************
--- LEAF for the clientOtxTlhAlarms3 article
--- *****************************************************
pm801rrAlmclientOtxTlhAlarms3 OBJECT IDENTIFIER ::= { pm801rrAlmClientUrg 22 }
pm801rrAlmClientLaserTempHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Laser Temp. High Alarm
:Alarm indicating the Line 1 OTX
TLH laser temperature is higher
than the threshold written in the
EEPROM <Condtype> CLIENT_LASER_TEMP_HIGH_ALA
<Probcause> temperatureUnacceptable
(51) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmclientOtxTlhAlarms3 14 }
pm801rrAlmClientFreqDevHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Freq. Deviation High Alarm
:Alarm indicating the Line 1 OTX
TLH frequency deviation is higher
than the threshold written in the
EEPROM <Condtype> CLIENT_FREQ_DEV_HIGH_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmclientOtxTlhAlarms3 12 }
pm801rrAlmClientCdrNotReady OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 CDR Not Ready :This OID
indicates the Clock Data Recovery
unit is not yet initialized
<Help> This alarm indicates
the Clock Data Recovery unit is
not yet initialized. <Condtype>
CLIENT_CDR_NOT_READY <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmclientOtxTlhAlarms3 9 }
pm801rrAlmClientAgingHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 OTX TLH Aging High Alarm
:Alarm indicating the Line 1 OTX
TLH aging is higher than the threshold
written in the EEPROM <Condtype>
CLIENT_AGING_HIGH_ALA <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmclientOtxTlhAlarms3 6 }
pm801rrAlmClientModulatorAgingHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Modulator Aging High Alarm
:Alarm indicating the Line 1 OTX
TLH modulator aging is higher than
the threshold written in the EEPROM
<Condtype> CLIENT_MODULATOR_AGING_HIGH_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmclientOtxTlhAlarms3 5 }
--- *****************************************************
--- LEAF for the clientOtxTlhWarnings article
--- *****************************************************
pm801rrAlmclientOtxTlhWarnings OBJECT IDENTIFIER ::= { pm801rrAlmClientNurg 23 }
pm801rrAlmClientLaserTempHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Laser Temp. High Warning
:Warning indicating the Line 1
OTX TLH laser temperature is higher
than the threshold written in the
EEPROM <Condtype> CLIENT_LASER_TEMP_HIGH_WARNING
<Probcause> temperatureUnacceptable
(51) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmclientOtxTlhWarnings 14 }
pm801rrAlmClientFreqDevHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Freq. Deviation High Warning
:Warning indicating the Line 1
OTX TLH frequency deviation is
higher than the threshold written
in the EEPROM <Condtype> CLIENT_FREQ_DEV_HIGH_WARNING
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmclientOtxTlhWarnings 12 }
pm801rrAlmClientAgingHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 OTX TLH Aging High Warning
:Warning indicating the Line 1
OTX TLH aging is higher than the
threshold written in the EEPROM
<Condtype> CLIENT_AGING_HIGH_WARNING
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmclientOtxTlhWarnings 6 }
pm801rrAlmClientModulatorAgingHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Modulator Aging High Warning
:Warning indicating the Line 1
OTX TLH modulator aging is higher
than the threshold written in the
EEPROM <Condtype> CLIENT_MODULATOR_AGING_HIGH_WARNING
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmclientOtxTlhWarnings 5 }
--- *****************************************************
--- LEAF for the lineXfpAlarm1 article
--- *****************************************************
pm801rrAlmlineXfpAlarm1 OBJECT IDENTIFIER ::= { pm801rrAlmLineUrg 24 }
pm801rrAlmLineRxPwrHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Rx Power High :Alarm
indicating that the Line 2 XFP/OTX
received optical power is higher
than the threshold value written
in the Line 2 XFP/OTX EEPROM <Condtype>
LINE_RX_PWR_HIGH_ALA <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpAlarm1 16 }
pm801rrAlmLineRxPwrLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Rx Power Low :Alarm
indicating that the Line 2 XFP/OTX
received optical power is lower
than the threshold value written
in the Line 2 XFP/OTX EEPROM <Condtype>
LINE_RX_PWR_LOW_ALA <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpAlarm1 15 }
pm801rrAlmLineTempHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Transceiver Temp High :Alarm
indicating that the Line 2 XFP/OTX
temperature is higher than the
threshold value written in the
Line 2 XFP/OTX EEPROM <Condtype>
LINE_TEMP_HIGH_ALA <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpAlarm1 8 }
pm801rrAlmLineTempLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Transceiver Temp Low :Alarm
indicating that the Line 2 XFP/OTX
temperature is lower than the threshold
value written in the Line 2 XFP/OTX
EEPROM <Condtype> LINE_TEMP_LOW_ALA
<Probcause> temperatureUnacceptable
(51) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpAlarm1 7 }
pm801rrAlmLineTxBiasHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Transceiver Bias High :Alarm
indicating that the Line 2 XFP/OTX
transmitter laser bias current
is higher than the threshold value
written in the Line 2 XFP/OTX EEPROM
<Condtype> LINE_TX_BIAS_HIGH_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpAlarm1 4 }
pm801rrAlmLineTxBiasLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Transceiver Bias Low :Alarm
indicating that the Line 2 XFP/OTX
transmitter laser bias current
is lower than the threshold value
written in the Line 2 XFP/OTX EEPROM
<Condtype> LINE_TX_BIAS_LOW_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpAlarm1 3 }
pm801rrAlmLineTxPwrHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Tx Power High :Alarm
indicating that the Line 2 XFP/OTX
transmitter transmitter output
power is higher than the threshold
value written in the Line 2 XFP/OTX
EEPROM <Condtype> LINE_TX_PWR_HIGH_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpAlarm1 2 }
pm801rrAlmLineTxPwrLowAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Tx Power Low :Alarm
indicating that the Line 2 XFP/OTX
transmitter transmitter output
power is lower than the threshold
value written in the Line 2 XFP/OTX
EEPROM <Condtype> LINE_TX_PWR_LOW_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpAlarm1 1 }
--- *****************************************************
--- LEAF for the lineXfpWarnings article
--- *****************************************************
pm801rrAlmlineXfpWarnings OBJECT IDENTIFIER ::= { pm801rrAlmLineNurg 25 }
pm801rrAlmLineRxPwrHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Rx Power High Warning
:Warning indicating that the Line
2 XFP/OTX received optical power
is higher than the threshold value
written in the Line 2 XFP/OTX EEPROM
<Condtype> LINE_RX_PWR_HIGH_WNG
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pm801rrAlmlineXfpWarnings 16 }
pm801rrAlmLineRxPwrLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Rx Power Low Warning
:Warning indicating that the Line
2 XFP/OTX received optical power
is lower than the threshold value
written in the Line 2 XFP/OTX EEPROM
<Condtype> LINE_RX_PWR_LOW_WNG
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pm801rrAlmlineXfpWarnings 15 }
pm801rrAlmLineTempHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Transceiver Temp High Warning
:Warning indicating that the Line
2 XFP/OTX temperature is higher
than the threshold value written
in the Line 2 XFP/OTX EEPROM <Condtype>
LINE_TEMP_HIGH_WNG <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpWarnings 8 }
pm801rrAlmLineTempLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Transceiver Temp Low Warning
:Warning indicating that the Line
2 XFP/OTX temperature is lower
than the threshold value written
in the Line 2 XFP/OTX EEPROM <Condtype>
LINE_TEMP_LOW_WNG <Probcause> temperatureUnacceptable
(51) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpWarnings 7 }
pm801rrAlmLineTxBiasHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Transceiver Bias High Warning
:Warning indicating that the Line
2 XFP/OTX transmitter laser bias
current is higher than the threshold
value written in the Line 2 XFP/OTX
EEPROM <Condtype> LINE_TX_BIAS_HIGH_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpWarnings 4 }
pm801rrAlmLineTxBiasLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Transceiver Bias Low Warning
:Warning indicating that the Line
2 XFP/OTX transmitter laser bias
current is lower than the threshold
value written in the Line 2 XFP/OTX
EEPROM <Condtype> LINE_TX_BIAS_LOW_WNG
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpWarnings 3 }
pm801rrAlmLineTxPwrHighWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Tx Power High Warning
:Warning indicating that the Line
2 XFP/OTX transmitter transmitter
output power is higher than the
threshold value written in the
Line 2 XFP/OTX EEPROM <Condtype>
LINE_TX_PWR_HIGH_WNG <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpWarnings 2 }
pm801rrAlmLineTxPwrLowWng OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Tx Power Low Warning
:Warning indicating that the Line
2 XFP/OTX transmitter transmitter
output power is lower than the
threshold value written in the
Line 2 XFP/OTX EEPROM <Condtype>
LINE_TX_PWR_LOW_WNG <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpWarnings 1 }
--- *****************************************************
--- LEAF for the lineXfpAlarms2 article
--- *****************************************************
pm801rrAlmlineXfpAlarms2 OBJECT IDENTIFIER ::= { pm801rrAlmLineCrit 27 }
pm801rrAlmLineApdSupplyFault OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Rx Photodiode Power Failed
:This OID indicates a failure on
the Line 2 APD power supply <Condtype>
LINE_APD_SUPPLY_FAULT <Probcause>
receiverFailure (42) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpAlarms2 16 }
pm801rrAlmLineTecFault OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Tx Temp Regul.
Failed :This OID indicates a failure
on the Line 2 TEC module <Condtype>
LINE_TEC_FAULT <Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpAlarms2 15 }
pm801rrAlmLineWavelengthUnlocked OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Tx Wavelength Unlocked
:This OID indicates that the Line
2 wavelength error is exceeding
the manufacturer tolerance <Condtype>
LINE_WAVELENGTH_UNLOCKED <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpAlarms2 14 }
pm801rrAlmLineChannelNotAcquired OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 DWDM Channel Not Acquired
:This OID indicates the transceiver
didn't tune the DWDM Channel succesfully.
<Help> This status indicates
the transceiver has not tuned
the DWDM Channel succesfully.
<Condtype> LINE_CHANNEL_NOT_ACQUIRED
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpAlarms2 10 }
pm801rrAlmLineTxNr OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Tx Not Ready :This
OID indicates a condition has arisen
leading to invalid data on the
Line 2 transmitting side <Condtype>
LINE_TX_NR <Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpAlarms2 8 }
pm801rrAlmLineTxFault OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Tx Failure :This
OID indicates a fault condition
on the Line 2 laser detected by
the safety syste <Condtype> LINE_TX_FAULT
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpAlarms2 7 }
pm801rrAlmLineTxCdrNotLocked OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Tx CDR Unlocked
:This OID indicates a loss of lock
on the Line 2 transmitting side
CDR has been detected. <Condtype>
LINE_TX_CDR_NOT_LOCKED <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpAlarms2 6 }
pm801rrAlmLineRxNr OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Rx Not Ready :This
OID indicates that a condition
has arisen leading to invalid
data on the Line 2 receiving side.
<Condtype> LINE_RX_NR <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpAlarms2 5 }
pm801rrAlmLineRxLos OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Loss Of Optical Signal
:This bit indicates an absence
of signal on the XFP/OTX <Help>
This alarm indicates if an optical
signal is detected on the line
2 transceiver input <Condtype>
LINE_RX_LOS <Probcause> receiveFailure
(41) <Alarmtype> physicalViolation
(9) <Polarity> (2)
"
::= { pm801rrAlmlineXfpAlarms2 4 }
pm801rrAlmLineRxCdrNotLocked OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Rx CDR Unlocked
:This OID indicates that a loss
of lock on the Line 2 receiving
side CDR has been detected <Condtype>
LINE_RX_CDR_NOT_LOCKED <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmlineXfpAlarms2 3 }
pm801rrAlmLineResetComplete OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Not Used :This bit indicates that
the internal reset process is completed
and the data are available <Condtype>
LINE_RESET_COMPLETE <Probcause>
other (1) <Alarmtype> other (1)
<Polarity> (2)
"
::= { pm801rrAlmlineXfpAlarms2 1 }
--- *****************************************************
--- LEAF for the rrLineOtxTlhAlarms3 article
--- *****************************************************
pm801rrAlmrrLineOtxTlhAlarms3 OBJECT IDENTIFIER ::= { pm801rrAlmLineUrg 30 }
pm801rrAlmLineLaserTempHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Laser Temp. High Alarm
:Alarm indicating the Line 2 OTX
TLH laser temperature is higher
than the threshold written in the
EEPROM <Condtype> LINE_LASER_TEMP_HIGH_ALA
<Probcause> temperatureUnacceptable
(51) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmrrLineOtxTlhAlarms3 14 }
pm801rrAlmLineFreqDevHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Freq. Deviation High Alarm
:Alarm indicating the Line 2 OTX
TLH frequency deviation is higher
than the threshold written in the
EEPROM <Condtype> LINE_FREQ_DEV_HIGH_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmrrLineOtxTlhAlarms3 12 }
pm801rrAlmLineCdrNotReady OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 CDR Not Ready :This OID
indicates the Clock Data Recovery
unit is not yet initialized
<Help> This alarm indicates
the Clock Data Recovery unit is
not yet initialized. <Condtype>
LINE_CDR_NOT_READY <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmrrLineOtxTlhAlarms3 9 }
pm801rrAlmLineAgingHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 OTX TLH Aging High Alarm
:Alarm indicating the Line 2 OTX
TLH aging is higher than the threshold
written in the EEPROM <Condtype>
LINE_AGING_HIGH_ALA <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm801rrAlmrrLineOtxTlhAlarms3 6 }
pm801rrAlmLineModulatorAgingHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Modulator Aging High Alarm
:Alarm indicating the Line 2 OTX
TLH modulator aging is higher than
the threshold written in the EEPROM
<Condtype> LINE_MODULATOR_AGING_HIGH_ALA
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmrrLineOtxTlhAlarms3 5 }
--- *****************************************************
--- LEAF for the rrLineOtxTlhWarnings article
--- *****************************************************
pm801rrAlmrrLineOtxTlhWarnings OBJECT IDENTIFIER ::= { pm801rrAlmLineNurg 31 }
pm801rrAlmLineLaserTempHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Laser Temp. High Warning
:Warning indicating the Line 2
OTX TLH laser temperature is higher
than the threshold written in the
EEPROM <Condtype> LINE_LASER_TEMP_HIGH_WARNING
<Probcause> temperatureUnacceptable
(51) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmrrLineOtxTlhWarnings 14 }
pm801rrAlmLineFreqDevHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Freq. Deviation High Warning
:Warning indicating the Line 2
OTX TLH frequency deviation is
higher than the threshold written
in the EEPROM <Condtype> LINE_FREQ_DEV_HIGH_WARNING
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmrrLineOtxTlhWarnings 12 }
pm801rrAlmLineAgingHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 OTX TLH Aging High Warning
:Warning indicating the Line 2
OTX TLH aging is higher than the
threshold written in the EEPROM
<Condtype> LINE_AGING_HIGH_WARNING
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmrrLineOtxTlhWarnings 6 }
pm801rrAlmLineModulatorAgingHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Modulator Aging High Warning
:Warning indicating the Line 2
OTX TLH modulator aging is higher
than the threshold written in the
EEPROM <Condtype> LINE_MODULATOR_AGING_HIGH_WARNING
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm801rrAlmrrLineOtxTlhWarnings 5 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONTROLS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the synth0 article
--- *****************************************************
pm801rrCtrlsynth0 OBJECT IDENTIFIER ::= { pm801rrCtrlOther 0 }
pm801rrCtrlConfClear OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Clear Configuration Tables :This
bit clears the configuration tables
from configuration in the flash.
<Help> This control restores
the default configuration of the
module
"
::= { pm801rrCtrlsynth0 13 }
pm801rrCtrlConfFlash OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Write Configuration Tables :This
bit saves the current configuration
of the module as configuration
in the flash. <Help> This control
saves the customer configuration
on the module
"
::= { pm801rrCtrlsynth0 9 }
pm801rrCtrlConfLoad OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Load Configuration Tables :When
set this enables loading from flash
configuration1 into the module.
"
::= { pm801rrCtrlsynth0 1 }
--- *****************************************************
--- LEAF for the synth4 article
--- *****************************************************
pm801rrCtrlsynth4 OBJECT IDENTIFIER ::= { pm801rrCtrlOther 4 }
pm801rrCtrlCorrelatOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Disable Alarm Correlation :This
OID disables the alarm correlation
in the PM
"
::= { pm801rrCtrlsynth4 2 }
pm801rrCtrlCorrelatOn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Enable Alarm Correlation :This
OID enables the alarm correlation
in the PM
"
::= { pm801rrCtrlsynth4 1 }
--- *****************************************************
--- LEAF for the swMgnt article
--- *****************************************************
pm801rrCtrlswMgnt OBJECT IDENTIFIER ::= { pm801rrCtrlOther 5 }
pm801rrCtrlWarmReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Software Warm Reset :This OID,
when set, causes a warm reset of
the Software. This reset is not
traffic affecting, and the configuration
of the Sofwtare remains unchanged.
<Help> This control initiates
a warm reset of the module.
"
::= { pm801rrCtrlswMgnt 3 }
pm801rrCtrlColdReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Software Cold Reset :This OID,
when set, causes a cold reset of
the Software. This reset is traffic
affecting, and the configuration
of Software is reloaded on start-up.
<Help> This control initiates
a cold reset of the module.
"
::= { pm801rrCtrlswMgnt 2 }
--- *****************************************************
--- LEAF for the clientXfpOnoff article
--- *****************************************************
pm801rrCtrlclientXfpOnoff OBJECT IDENTIFIER ::= { pm801rrCtrlClient 16 }
pm801rrCtrlClientXfpOnoff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
XFP/OTX Laser Shut Down :This
OID switches off the Line 1 XFP/OTX
<Help> This control defines the
laser state of the line 1 transceiver
"
::= { pm801rrCtrlclientXfpOnoff 1 }
--- *****************************************************
--- LEAF for the clientXfpLineLoop article
--- *****************************************************
pm801rrCtrlclientXfpLineLoop OBJECT IDENTIFIER ::= { pm801rrCtrlClient 17 }
pm801rrCtrlClientXfpLineLoop OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
XFP/OTX Loop :This OID operates
a loopback on the Line 1 XFP/OTX
<Help> This control defines the
line loop back of the line 1 transceiver
"
::= { pm801rrCtrlclientXfpLineLoop 1 }
--- *****************************************************
--- LEAF for the clientXfiLoop article
--- *****************************************************
pm801rrCtrlclientXfiLoop OBJECT IDENTIFIER ::= { pm801rrCtrlClient 18 }
pm801rrCtrlClientXfiLoop OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
XFP/OTX XFI Loop :This OID operates
a XFI loopback on the Line 1 XFP/OTX
<Help> This control defines
the XFI loop back of the line
transceiver
"
::= { pm801rrCtrlclientXfiLoop 1 }
--- *****************************************************
--- LEAF for the clientTunableChannel article
--- *****************************************************
pm801rrCtrlclientTunableChannel OBJECT-TYPE
SYNTAX Pm801rrOtxChannel
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
ITU Channel :This OID selects
the ITU channel of the Line 1
OTX TLH Laser <Help> This control
defines the ITU channel of the
Line 1 OTX TLH Laser
"
::= { pm801rrCtrlClient 19 }
--- *****************************************************
--- LEAF for the clientPhotodiodeMode article
--- *****************************************************
pm801rrCtrlclientPhotodiodeMode OBJECT-TYPE
SYNTAX Pm801rrOtxMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
OTX TLH Rx Sens. Mode :This OID
defines the Rx sensiblity mode
of the Line 1 OTX TLH <Help>
This control defines the receiver
sensibility mode of the Line 1
OTX TLH Laser (OTX60, OTX80 or
Custom)
"
::= { pm801rrCtrlClient 20 }
--- *****************************************************
--- LEAF for the clientPhotodiodeValue article
--- *****************************************************
pm801rrCtrlclientPhotodiodeValue OBJECT-TYPE
SYNTAX Pm801rrAdjustValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
OTX TLH Rx Sensibility :This OID
sets the Rx sensibility of the
Line 1 OTX TLH (custom mode only)
<Help> This control defines
the receiver sensibility value
(only in Custom mode) of the Line
1 OTX TLH Laser
"
::= { pm801rrCtrlClient 21 }
--- *****************************************************
--- LEAF for the clientPowerLaser article
--- *****************************************************
pm801rrCtrlclientPowerLaser OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Laser Output Power [3-5] :This
OID sets the output power value
on the laser of the Line 1 OTX
TLH (AV=Power*10+158) (Unit =
dBm) <Help> This control defines
the start-up output power of the
Line 1 OTX TLH
"
::= { pm801rrCtrlClient 22 }
--- *****************************************************
--- LEAF for the clientOtxVlhReset article
--- *****************************************************
pm801rrCtrlclientOtxVlhReset OBJECT IDENTIFIER ::= { pm801rrCtrlLine 23 }
pm801rrCtrlClientOtxVlhReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
OTX-VLH Reset :This OID resets
the OTX-VLH module <Help> This
control resets the OTX-TLH and
its parameters
"
::= { pm801rrCtrlclientOtxVlhReset 1 }
--- *****************************************************
--- LEAF for the lineXfpOnoff article
--- *****************************************************
pm801rrCtrllineXfpOnoff OBJECT IDENTIFIER ::= { pm801rrCtrlLine 24 }
pm801rrCtrlLineXfpOnoff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
XFP/OTX Laser Shut Down :This
OID switches off the Line 2 XFP/OTX
<Help> This control defines the
laser state of the line 2 transceiver
"
::= { pm801rrCtrllineXfpOnoff 1 }
--- *****************************************************
--- LEAF for the lineXfpLineLoop article
--- *****************************************************
pm801rrCtrllineXfpLineLoop OBJECT IDENTIFIER ::= { pm801rrCtrlLine 25 }
pm801rrCtrlLineXfpLineLoop OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
XFP/OTX Loop :This OID operates
a loopback on the Line 2 XFP/OTX
<Help> This control defines the
line loop back of the line 2 transceiver
"
::= { pm801rrCtrllineXfpLineLoop 1 }
--- *****************************************************
--- LEAF for the lineXfiLoop article
--- *****************************************************
pm801rrCtrllineXfiLoop OBJECT IDENTIFIER ::= { pm801rrCtrlLine 26 }
pm801rrCtrlLineXfiLoop OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
XFP/OTX XFI Loop :This OID operates
a XFI loopback on the Line 2 XFP/OTX
<Help> This control defines
the XFI loop back of the line
2 transceiver
"
::= { pm801rrCtrllineXfiLoop 1 }
--- *****************************************************
--- LEAF for the lineTunableChannel article
--- *****************************************************
pm801rrCtrllineTunableChannel OBJECT-TYPE
SYNTAX Pm801rrOtxChannel
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
ITU Channel :This OID selects
the ITU channel of the Line 2
OTX TLH Laser <Help> This control
defines the ITU channel of the
Line 2 OTX TLH Laser
"
::= { pm801rrCtrlLine 27 }
--- *****************************************************
--- LEAF for the linePhotodiodeMode article
--- *****************************************************
pm801rrCtrllinePhotodiodeMode OBJECT-TYPE
SYNTAX Pm801rrOtxMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
OTX TLH Rx Sens. Mode :This OID
defines the Rx sensiblity mode
of the Line 2 OTX TLH <Help>
This control defines the receiver
sensibility mode of the Line 2
OTX TLH Laser (OTX60, OTX80 or
Custom)
"
::= { pm801rrCtrlLine 28 }
--- *****************************************************
--- LEAF for the linePhotodiodeValue article
--- *****************************************************
pm801rrCtrllinePhotodiodeValue OBJECT-TYPE
SYNTAX Pm801rrAdjustValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
OTX TLH Rx Sensibility :This OID
sets the Rx sensibility of the
Line 2 OTX TLH (custom mode only)
<Help> This control defines
the receiver sensibility value
(only in Custom mode) of the Line
2 OTX TLH Laser
"
::= { pm801rrCtrlLine 29 }
--- *****************************************************
--- LEAF for the linePowerLaser article
--- *****************************************************
pm801rrCtrllinePowerLaser OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Laser Output Power [3-5] :This
OID sets the output power value
on the laser of the Line 2 OTX
TLH (AV=Power*10+158) (Unit =
dBm) <Help> This control defines
the start-up output power of the
Line 2 OTX TLH
"
::= { pm801rrCtrlLine 30 }
--- *****************************************************
--- LEAF for the lineOtxVlhReset article
--- *****************************************************
pm801rrCtrllineOtxVlhReset OBJECT IDENTIFIER ::= { pm801rrCtrlLine 31 }
pm801rrCtrlLineOtxVlhReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
OTX-VLH Reset :This OID resets
the OTX-VLH module <Help> This
control resets the OTX-TLH and
its parameters
"
::= { pm801rrCtrllineOtxVlhReset 1 }
--- *****************************************************
--- LEAF for the ledTest article
--- *****************************************************
pm801rrCtrlledTest OBJECT IDENTIFIER ::= { pm801rrCtrlOther 64 }
pm801rrCtrlLedOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Leds Off :This OID switches off
all the Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to OFF
"
::= { pm801rrCtrlledTest 3 }
pm801rrCtrlRedLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Red Leds Test :This OID switches
on all the red Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to red
"
::= { pm801rrCtrlledTest 2 }
pm801rrCtrlGreenLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Green Leds Test :This OID switches
on all the green Leds as a test
feature. <Help> This control
initiates a test leds turning
all the LEDs to green
"
::= { pm801rrCtrlledTest 1 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- MEASURES
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the clientTemperature article
--- *****************************************************
pm801rrMesrclientTemperature OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Module Temperature
:This OID gives the temperature
of the Client XFP/OTX, read from
the DDM (Digital Diagnostic Monitoring)
(Temperature = AV/256) (Unit =
C) <Help> This measure gives
the temperature of the line 1
transceiver
"
::= { pm801rrMesrClient 16 }
--- *****************************************************
--- LEAF for the clientTxBias article
--- *****************************************************
pm801rrMesrclientTxBias OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 XFP/OTX Tx Bias Current
:This OID gives the bias value
of the Client XFP/OTX, read from
the DDM (Digital Diagnostic Monitoring)
(Bias = AV/500) (Unit = mA) <Help>
This measure gives the bias of
the line 1 transceiver
"
::= { pm801rrMesrClient 18 }
--- *****************************************************
--- LEAF for the clientTxPower article
--- *****************************************************
pm801rrMesrclientTxPower OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Module Tx Power
:This OID gives the transmit power
value of the Client XFP/OTX, read
from the DDM (Digital Diagnostic
Monitoring) (Power = 10*log(AV)-40)
(Unit = dBm) <Help> This measure
gives the Tx optical power of the
line 1 transceiver
"
::= { pm801rrMesrClient 19 }
--- *****************************************************
--- LEAF for the clientRxPower article
--- *****************************************************
pm801rrMesrclientRxPower OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Module Rx Power
:This OID gives the receive power
value of the Client XFP/OTX, read
from the DDM (Digital Diagnostic
Monitoring) (Power = 10*log(AV)-40)
(Unit = dBm) <Help> This measure
gives the Rx optical power of the
line 1 transceiver
"
::= { pm801rrMesrClient 20 }
--- *****************************************************
--- LEAF for the lineTemperature article
--- *****************************************************
pm801rrMesrlineTemperature OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Module Temperature
:This OID gives the temperature
of the Line XFP/OTX, read from
the DDM (Digital Diagnostic Monitoring)
(Temperature = AV/256) (Unit =
C) <Help> This measure gives
the temperature of the line 2
transceiver
"
::= { pm801rrMesrLine 24 }
--- *****************************************************
--- LEAF for the lineTxBias article
--- *****************************************************
pm801rrMesrlineTxBias OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 XFP/OTX Tx Bias Current
:This OID gives the bias value
of the Line XFP/OTX, read from
the DDM (Digital Diagnostic Monitoring)
(Bias = AV/500) (Unit = mA) <Help>
This measure gives the bias of
the line 2 transceiver
"
::= { pm801rrMesrLine 26 }
--- *****************************************************
--- LEAF for the lineTxPower article
--- *****************************************************
pm801rrMesrlineTxPower OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Module Tx Power
:This OID gives the transmit power
value of the Line XFP/OTX, read
from the DDM (Digital Diagnostic
Monitoring) (Power = 10*log(AV)-40)
(Unit = dBm) <Help> This measure
gives the Tx optical power of the
line 2 transceiver
"
::= { pm801rrMesrLine 27 }
--- *****************************************************
--- LEAF for the lineRxPower article
--- *****************************************************
pm801rrMesrlineRxPower OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Module Rx Power
:This OID gives the receive power
value of the Line XFP/OTX, read
from the DDM (Digital Diagnostic
Monitoring) (Power = 10*log(AV)-40)
(Unit = dBm) <Help> This measure
gives the Rx optical power of the
line 2 transceiver
"
::= { pm801rrMesrLine 28 }
--- *****************************************************
--- LEAF for the clientAging article
--- *****************************************************
pm801rrMesrclientAging OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 OTX TLH Aging :This OID
gives the aging of the Line 1 OTX
TLH, read from the DDM (Digital
Diagnostic Monitoring) (Aging
= AV) (Unit = %) <Help> This
measure gives the aging of the
line 1 OTX TLH
"
::= { pm801rrMesrClient 32 }
--- *****************************************************
--- LEAF for the clientLaserTemperature article
--- *****************************************************
pm801rrMesrclientLaserTemperature OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 OTX TLH Laser Temperature
:This OID gives the laser temperature
of the Line 1 OTX TLH, read from
the DDM (Digital Diagnostic Monitoring)
(Temperature = AV/256) (Unit
= C) <Help> This measure gives
the laser temperature of the line
1 OTX TLH
"
::= { pm801rrMesrClient 33 }
--- *****************************************************
--- LEAF for the clientFreqDeviation article
--- *****************************************************
pm801rrMesrclientFreqDeviation OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 OTX TLH Frequency Deviation
:This OID gives the frequency deviation
of the Line 1 OTX TLH, read from
the DDM (Digital Diagnostic Monitoring)
(Deviation = (AV-32768)*100) (Unit
= MHz) <Help> This measure gives
the frequency deviation of the
line 1 OTX TLH
"
::= { pm801rrMesrClient 34 }
--- *****************************************************
--- LEAF for the clientLaserWvlength article
--- *****************************************************
pm801rrMesrclientLaserWvlength OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 1 Optical Module Wavelength
:This OID gives the laser wavelength
of the Line 1 OTX TLH, read from
the DDM (Digital Diagnostic Monitoring)
(Wavelength=299792458/((193,100+(AV-32768
)*12,5)*10 3)) (Unit = nm) <Help>
This measure gives the laser
wavelength of the line 1 OTX TLH
"
::= { pm801rrMesrClient 35 }
--- *****************************************************
--- LEAF for the lineAging article
--- *****************************************************
pm801rrMesrlineAging OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 OTX TLH Aging :This OID
gives the aging of the Line 2 OTX
TLH, read from the DDM (Digital
Diagnostic Monitoring) (Aging
= AV) (Unit = %) <Help> This
measure gives the aging of the
line 2 OTX TLH
"
::= { pm801rrMesrLine 40 }
--- *****************************************************
--- LEAF for the lineLaserTemperature article
--- *****************************************************
pm801rrMesrlineLaserTemperature OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 OTX TLH Laser Temperature
:This OID gives the laser temperature
of the Line 2 OTX TLH, read from
the DDM (Digital Diagnostic Monitoring)
(Temperature = AV/256) (Unit
= C) <Help> This measure gives
the laser temperature of the line
2 OTX TLH
"
::= { pm801rrMesrLine 41 }
--- *****************************************************
--- LEAF for the lineFreqDeviation article
--- *****************************************************
pm801rrMesrlineFreqDeviation OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 OTX TLH Frequency Deviation
:This OID gives the frequency deviation
of the Line 2 OTX TLH, read from
the DDM (Digital Diagnostic Monitoring)
(Deviation = (AV-32768)*100) (Unit
= MHz) <Help> This measure gives
the frequency deviation of the
line 2 OTX TLH
"
::= { pm801rrMesrLine 42 }
--- *****************************************************
--- LEAF for the lineLaserWvlength article
--- *****************************************************
pm801rrMesrlineLaserWvlength OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line 2 Optical Module Wavelength
:This OID gives the laser wavelength
of the Line 2 OTX TLH, read from
the DDM (Digital Diagnostic Monitoring)
(Wavelength=299792458/((193,100+(AV-32768
)*12,5)*10 3)) (Unit = nm) <Help>
This measure gives the laser wavelength
of the line 2 OTX TLH
"
::= { pm801rrMesrLine 43 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONFIG
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the table Group lsd
--- *****************************************************
pm801rrCfgLsd OBJECT IDENTIFIER ::= { pm801rrConfig 1 }
--- *****************************************************
--- LEAF for the table 0012
--- *****************************************************
pm801rrtableclientLsd OBJECT IDENTIFIER ::= { pm801rrCfgLsd 1 }
pm801rrCfglsdMode OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
LSD mode on Client/Line Port
:This OID enables/disables the
automatic laser shutdown on the
Client and Line ports
"
::= { pm801rrtableclientLsd 2 }
pm801rrCfgclientXfpAlarms OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
LSD contributors on Client port
:This OID configures the contributors
for the automatic laser shutdown
of the client port
"
::= { pm801rrtableclientLsd 3 }
pm801rrCfgclientXfpAbsence OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
LSD contributors on Client port
:This OID configures the contributors
for the automatic laser shutdown
of the client port
"
::= { pm801rrtableclientLsd 4 }
pm801rrCfglineXfpAlarms OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
LSD contributors on Line port
:This OID configures the contributors
for the automatic laser shutdown
of the line port
"
::= { pm801rrtableclientLsd 5 }
pm801rrCfglineXfpAbsence OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
LSD contributors on Line port
:This OID configures the contributors
for the automatic laser shutdown
of the line port
"
::= { pm801rrtableclientLsd 6 }
--- *****************************************************
--- LEAF for the table Group startUp
--- *****************************************************
pm801rrCfgStartUp OBJECT IDENTIFIER ::= { pm801rrConfig 2 }
--- *****************************************************
--- LEAF for the table 2111
--- *****************************************************
pm801rrtableclientStartup OBJECT IDENTIFIER ::= { pm801rrCfgStartUp 1 }
pm801rrCfgclientXfpCtrl OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Line 1 Port
:This register configures the
default initialisation settings
on the client port.
"
::= { pm801rrtableclientStartup 2 }
--- *****************************************************
--- LEAF for the table 2191
--- *****************************************************
pm801rrtablelineStartup OBJECT IDENTIFIER ::= { pm801rrCfgStartUp 2 }
pm801rrCfglineXfpCtrl OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Line 2 Port
:This register configures the
default initialisation settings
on the line port.
"
::= { pm801rrtablelineStartup 2 }
pm801rrCfgprotocolSelect OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Bitrate selection on Line/Client
port :This OID register configure
the bitrate for the client and
line interface (0=9,953 Gb/s -
1=10,3125 Gb/s - 2=9,953 Gb/s -
3=10,518 Gb/s - 4=10,664 Gb/s -
5=10,709 Gb/s).
"
::= { pm801rrtablelineStartup 18 }
--- *****************************************************
--- LEAF for the table 2511
--- *****************************************************
pm801rrtableclientOtxtlh OBJECT IDENTIFIER ::= { pm801rrCfgStartUp 3 }
pm801rrCfgclientDitherControl OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Dither Line
1 :This register configures the
default initialisation settings
on the dither of the client port.
"
::= { pm801rrtableclientOtxtlh 2 }
pm801rrCfgclientDitherRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Line 1 OTX TLH FM amplitude
:This register configures the start-up
width of the frequency modulation
of the line 1 OTX TLH
"
::= { pm801rrtableclientOtxtlh 3 }
pm801rrCfgclientDitherFhz OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Line 1 OTX TLH FM frequency
:This register configures the start-up
frequency of the frequency modulation
of the line 1 OTX TLH
"
::= { pm801rrtableclientOtxtlh 4 }
pm801rrCfgclientPwrLaser OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Defaut Line 1 OTX TLH output Power
:This register configures the start-up
output power of the line 1 OTX
TLH (Unit = dBm)
"
::= { pm801rrtableclientOtxtlh 5 }
pm801rrCfgclientFCurrent OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Line 1 OTX TLH Channel
:This register configures the start-up
laser channel of the line 1 OTX
TLH
"
::= { pm801rrtableclientOtxtlh 6 }
pm801rrCfgclientGridCurrent OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Line 1 OTX TLH Grid :This
register configures the start-up
laser grid of the line 1 OTX TLH
"
::= { pm801rrtableclientOtxtlh 7 }
pm801rrCfgclientF0 OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Line 1 OTX TLH lowest
Freq :This register configures
the start-up lowest frequency supported
on the line 1 OTX TLH
"
::= { pm801rrtableclientOtxtlh 8 }
pm801rrCfgclientPhotodiodeMode OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Line 1 OTX TLH APD mode
:This register configures the start-up
APD mode of the line 1 OTX TLH
"
::= { pm801rrtableclientOtxtlh 10 }
pm801rrCfgclientPhotodiodeValue OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Line 1 OTX TLH APD atten.
:This register configures the start-up
APD attenuation on the line 1 OTX
TLH
"
::= { pm801rrtableclientOtxtlh 11 }
--- *****************************************************
--- LEAF for the table 2591
--- *****************************************************
pm801rrtablelineOtxtlh OBJECT IDENTIFIER ::= { pm801rrCfgStartUp 4 }
pm801rrCfglineDitherControl OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Dither Line
2 :This register configures the
default initialisation settings
on the dither of the client port.
"
::= { pm801rrtablelineOtxtlh 2 }
pm801rrCfglineDitherRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Line 2 OTX TLH FM amplitude
:This register configures the start-up
width of the frequency modulation
of the line 2 OTX TLH
"
::= { pm801rrtablelineOtxtlh 3 }
pm801rrCfglineDitherFhz OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Line 2 OTX TLH FM frequency
:This register configures the start-up
frequency of the frequency modulation
of the line 2 OTX TLH
"
::= { pm801rrtablelineOtxtlh 4 }
pm801rrCfglinePwrLaser OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Defaut Line 2 OTX TLH output Power
:This register configures the start-up
output power of the line 2 OTX
TLH (Unit = dBm)
"
::= { pm801rrtablelineOtxtlh 5 }
pm801rrCfglineFCurrent OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Line 2 OTX TLH Channel
:This register configures the start-up
laser channel of the line 2 OTX
TLH
"
::= { pm801rrtablelineOtxtlh 6 }
pm801rrCfglineGridCurrent OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Line 2 OTX TLH Grid :This
register configures the start-up
laser grid of the line 2 OTX TLH
"
::= { pm801rrtablelineOtxtlh 7 }
pm801rrCfglineF0 OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Line 2 OTX TLH lowest
Freq :This register configures
the start-up lowest frequency supported
on the line 2 OTX TLH
"
::= { pm801rrtablelineOtxtlh 8 }
pm801rrCfglinePhotodiodeMode OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Line 2 OTX TLH APD mode
:This register configures the start-up
APD mode of the line 2 OTX TLH
"
::= { pm801rrtablelineOtxtlh 10 }
pm801rrCfglinePhotodiodeValue OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Line 2 OTX TLH APD atten.
:This register configures the start-up
APD attenuation on the line 2 OTX
TLH
"
::= { pm801rrtablelineOtxtlh 11 }
--- *****************************************************
--- LEAF for the table Group labels
--- *****************************************************
pm801rrCfgLabels OBJECT IDENTIFIER ::= { pm801rrConfig 3 }
--- *****************************************************
--- LEAF for the table NO_VALUE
--- *****************************************************
pm801rrCfgLabelclientTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm801rrCfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pm801rrCfgLabels 1 }
pm801rrCfgLabelclientEntry OBJECT-TYPE
SYNTAX Pm801rrCfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pm801rrCfgLabelclientIndex }
::= { pm801rrCfgLabelclientTable 1 }
Pm801rrCfgLabelclientEntry ::=
SEQUENCE {
pm801rrCfgLabelclientIndex
INTEGER,
pm801rrCfgLabelclientPortn
DisplayString
}
pm801rrCfgLabelclientIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelclient
table
"
::= { pm801rrCfgLabelclientEntry 1 }
pm801rrCfgLabelclientPortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the Ports :These registers
configures the default initialisation
settings of the labels of the ports.
"
::= { pm801rrCfgLabelclientEntry 3 }
--- *****************************************************
--- LEAF for the table NO_VALUE
--- *****************************************************
pm801rrCfgLabellineTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm801rrCfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pm801rrCfgLabels 2 }
pm801rrCfgLabellineEntry OBJECT-TYPE
SYNTAX Pm801rrCfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pm801rrCfgLabellineIndex }
::= { pm801rrCfgLabellineTable 1 }
Pm801rrCfgLabellineEntry ::=
SEQUENCE {
pm801rrCfgLabellineIndex
INTEGER,
pm801rrCfgLabellinePortn
DisplayString
}
pm801rrCfgLabellineIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelline
table
"
::= { pm801rrCfgLabellineEntry 1 }
pm801rrCfgLabellinePortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the lines :These registers
configures the default initialisation
settings of the labels of the lines.
"
::= { pm801rrCfgLabellineEntry 3 }
--- *****************************************************
--- LEAF for the table Group startuptablefive
--- *****************************************************
pm801rrCfgStartuptablefive OBJECT IDENTIFIER ::= { pm801rrConfig 4 }
--- *****************************************************
--- LEAF for the table 0005
--- *****************************************************
pm801rrCfgOtxtlhcapabilitiesTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm801rrCfgOtxtlhcapabilitiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pm801rrCfgStartuptablefive 1 }
pm801rrCfgOtxtlhcapabilitiesEntry OBJECT-TYPE
SYNTAX Pm801rrCfgOtxtlhcapabilitiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the startuptablefive
table
"
INDEX { pm801rrCfgOtxtlhcapabilitiesIndex }
::= { pm801rrCfgOtxtlhcapabilitiesTable 1 }
Pm801rrCfgOtxtlhcapabilitiesEntry ::=
SEQUENCE {
pm801rrCfgOtxtlhcapabilitiesIndex
INTEGER,
pm801rrCfgComponentTypePortn
Unsigned32,
pm801rrCfgMiscellaneousPortn
Unsigned32,
pm801rrCfgFirstChannelPortn
Unsigned32,
pm801rrCfgLastChannelPortn
Unsigned32,
pm801rrCfgGridPortn
Unsigned32
}
pm801rrCfgOtxtlhcapabilitiesIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the otxtlhcapabilities
table
"
::= { pm801rrCfgOtxtlhcapabilitiesEntry 1 }
pm801rrCfgComponentTypePortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Component parameters :This OID
defines the component parameters
"
::= { pm801rrCfgOtxtlhcapabilitiesEntry 3 }
pm801rrCfgMiscellaneousPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Miscellaneous default settings
:This OID defines the miscellaneous
parameters
"
::= { pm801rrCfgOtxtlhcapabilitiesEntry 4 }
pm801rrCfgFirstChannelPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Number of the first channel of
the component :This OID defines
the first channel number of the
PM
"
::= { pm801rrCfgOtxtlhcapabilitiesEntry 5 }
pm801rrCfgLastChannelPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Number of the last channel of
the component :This OID defines
the last channel number of the
PM
"
::= { pm801rrCfgOtxtlhcapabilitiesEntry 6 }
pm801rrCfgGridPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Grid value of the component :This
OID defines the grid of the PM
"
::= { pm801rrCfgOtxtlhcapabilitiesEntry 7 }
pm801rrCfgWriteConfiguration OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Write configuration to module:This OID
writes the complete configuration to the module"
::= { pm801rrConfig 257 }
--- *****************************************************
--- TRAP OBJECTS
--- *****************************************************
pm801rrtrapBoardNumber OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last module which generates a trap"
::= { pm801rrtraps 4 }
--- *****************************************************
--- GLOBAL TRAPS
--- *****************************************************
pm801rrLineTrapNotUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pm801rrAlmLineDdmWarning, pm801rrtrapBoardNumber}
STATUS current
--&FILTNAME "PM801RR Line Not Urgent ON"
--&ACTIONS { log, minor }
--&MATCH { pm801rrAlmLineDdmWarning "on", pm801rrtrapBoardNumber "$2"}
--&MESG "DDM Warning appears on Line Port of PM801RR in Slot $2 ($A)"
DESCRIPTION "Not urgent Line default is activated"
::= { pm801rrtraps 30 }
pm801rrLineTrapNotUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pm801rrAlmLineDdmWarning, pm801rrtrapBoardNumber}
STATUS current
--&FILTNAME "PM801RR Line Not Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS { "PM801RR Line Not Urgent ON" }
--&MATCH { pm801rrAlmLineDdmWarning "on", pm801rrtrapBoardNumber "$2"}
--&MESG "DDM Warning disappears on Line Port of PM801RR in Slot $2 ($A)"
DESCRIPTION "Not urgent Line default disappeared"
::= { pm801rrtraps 31 }
pm801rrLineTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pm801rrAlmLineDdmAlm, pm801rrtrapBoardNumber}
STATUS current
--&FILTNAME "PM801RR Line Urgent ON"
--&ACTIONS { log, major }
--&MATCH { pm801rrAlmLineDdmAlm "on", pm801rrtrapBoardNumber "$2"}
--&MESG "DDM Alarm appears on Line Port of PM801RR in Slot $2 ($A)"
DESCRIPTION "Urgent Line default is activated"
::= { pm801rrtraps 32 }
pm801rrLineTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pm801rrAlmLineDdmAlm, pm801rrtrapBoardNumber}
STATUS current
--&FILTNAME "PM801RR Line Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS { "PM801RR Line Urgent ON" }
--&MATCH { pm801rrAlmLineDdmAlm "on", pm801rrtrapBoardNumber "$2"}
--&MESG "DDM Alarm disappears on Line Port of PM801RR in Slot $2 ($A)"
DESCRIPTION "Urgent Line default disappeared"
::= { pm801rrtraps 33 }
pm801rrLineTrapCritGoesOn NOTIFICATION-TYPE
OBJECTS {pm801rrAlmLineFail, pm801rrAlmLineHwFail, pm801rrtrapBoardNumber}
STATUS current
--&FILTNAME "PM801RR Line Fail ON"
--&ACTIONS { log, critical }
--&MATCH { pm801rrAlmLineFail "on", pm801rrAlmLineHwFail "*", pm801rrtrapBoardNumber "$3"}
--&MESG "Line Port Down on PM801RR in Slot $3 ($A)"
--&FILTNAME "PM801RR Line HW Fail ON (Hidden)"
--&ACTIONS { info }
--&MATCH { pm801rrAlmLineFail "*", pm801rrAlmLineHwFail "on", pm801rrtrapBoardNumber "$3"}
--&MESG "Line Port Down on PM801RR in Slot $3 ($A)"
DESCRIPTION "Critical Line default is activated"
::= { pm801rrtraps 34 }
pm801rrLineTrapCritGoesOff NOTIFICATION-TYPE
OBJECTS {pm801rrAlmLineFail, pm801rrAlmLineHwFail, pm801rrtrapBoardNumber}
STATUS current
--&FILTNAME "PM801RR Line Fail OFF"
--&ACTIONS { log, normal }
--&CLEARS { "PM801RR Line Fail ON" }
--&MATCH { pm801rrAlmLineFail "on", pm801rrAlmLineHwFail "*", pm801rrtrapBoardNumber "$3"}
--&MESG "Line Port Up on PM801RR in Slot $3 ($A)"
--&FILTNAME "PM801RR Line HW Fail OFF (Hidden)"
--&ACTIONS { info }
--&MATCH { pm801rrAlmLineFail "*", pm801rrAlmLineHwFail "on", pm801rrtrapBoardNumber "$3"}
--&MESG "Line Port Up on PM801RR in Slot $3 ($A)"
DESCRIPTION "Critical Line default disappeared"
::= { pm801rrtraps 35 }
--- *****************************************************
--- PORTS TRAPS
--- *****************************************************
pm801rrClientTrapNotUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pm801rrAlmClientDdmWarning, pm801rrtrapBoardNumber}
STATUS current
--&FILTNAME "PM801RR Client Not Urgent ON"
--&ACTIONS { log, minor }
--&MATCH { pm801rrAlmClientDdmWarning "on", pm801rrtrapBoardNumber "$2"}
--&MESG "DDM Warning appears on Client Port of PM801RR in Slot $2 ($A)"
DESCRIPTION "Not urgent client default is activated"
::= { pm801rrtraps 40 }
pm801rrClientTrapNotUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pm801rrAlmClientDdmWarning, pm801rrtrapBoardNumber}
STATUS current
--&FILTNAME "PM801RR Client Not Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS { "PM801RR Client Not Urgent ON" }
--&MATCH { pm801rrAlmClientDdmWarning "on", pm801rrtrapBoardNumber "$2"}
--&MESG "DDM Warning appears on Client Port of PM801RR in Slot $2 ($A)"
DESCRIPTION "Not urgent client default disappeared"
::= { pm801rrtraps 41 }
pm801rrClientTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pm801rrAlmClientDdmAlm, pm801rrtrapBoardNumber}
STATUS current
--&FILTNAME "PM801RR Client Urgent ON"
--&ACTIONS { log, major }
--&MATCH { pm801rrAlmClientDdmAlm "on", pm801rrtrapBoardNumber "$2"}
--&MESG "DDM Alarm appears on Client Port of PM801RR in Slot $2 ($A)"
DESCRIPTION "Urgent client default is activated"
::= { pm801rrtraps 42 }
pm801rrClientTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pm801rrAlmClientDdmAlm, pm801rrtrapBoardNumber}
STATUS current
--&FILTNAME "PM801RR Client Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS { "PM801RR Client Urgent ON" }
--&MATCH { pm801rrAlmClientDdmAlm "on", pm801rrtrapBoardNumber "$2"}
--&MESG "DDM Alarm disappears on Client Port of PM801RR in Slot $2 ($A)"
DESCRIPTION "Urgent client default disappeared"
::= { pm801rrtraps 43 }
pm801rrClientTrapCritGoesOn NOTIFICATION-TYPE
OBJECTS {pm801rrAlmClientFail, pm801rrAlmClientHwFail, pm801rrtrapBoardNumber}
STATUS current
--&FILTNAME "PM801RR Client Fail ON"
--&ACTIONS { log, critical }
--&MATCH { pm801rrAlmClientFail "on", pm801rrAlmClientHwFail "*", pm801rrtrapBoardNumber "$3"}
--&MESG "Client Port Down on PM801RR in Slot $3 ($A)"
--&FILTNAME "PM801RR Client HW Fail ON (Hidden)"
--&ACTIONS { info }
--&MATCH { pm801rrAlmClientFail "*", pm801rrAlmClientHwFail "on", pm801rrtrapBoardNumber "$3"}
--&MESG "Client Port Down on PM801RR in Slot $3 ($A)"
DESCRIPTION "Critical client default is activated"
::= { pm801rrtraps 44 }
pm801rrClientTrapCritGoesOff NOTIFICATION-TYPE
OBJECTS {pm801rrAlmClientFail, pm801rrAlmClientHwFail, pm801rrtrapBoardNumber}
STATUS current
--&FILTNAME "PM801RR Client Fail OFF"
--&ACTIONS { log, normal }
--&CLEARS { "PM801RR Client Fail ON" }
--&MATCH { pm801rrAlmClientFail "on", pm801rrAlmClientHwFail "*", pm801rrtrapBoardNumber "$3"}
--&MESG "Client Port Up on PM801RR in Slot $3 ($A)"
--&FILTNAME "PM801RR Client HW Fail OFF (Hidden)"
--&ACTIONS { info }
--&MATCH { pm801rrAlmClientFail "*", pm801rrAlmClientHwFail "on", pm801rrtrapBoardNumber "$3"}
--&MESG "Client Port Up on PM801RR in Slot $3 ($A)"
DESCRIPTION "Critical client default disappeared"
::= { pm801rrtraps 45 }
--- *****************************************************
--- HW TRAPS
--- *****************************************************
pm801rrPowerTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pm801rrAlmDefFuseB, pm801rrAlmDefFuseA , pm801rrtrapBoardNumber}
STATUS current
--&FILTNAME "PM801RR Fuse A Fail ON"
--&ACTIONS { log, major }
--&MATCH { pm801rrAlmDefFuseB "*", pm801rrAlmDefFuseA "on", pm801rrtrapBoardNumber "$3"}
--&MESG "Power Input A Fail on PM801RR in Slot $3 ($A)"
--&FILTNAME "PM801RR Fuse B Fail ON"
--&ACTIONS { log, major }
--&MATCH { pm801rrAlmDefFuseB "on", pm801rrAlmDefFuseA "*", pm801rrtrapBoardNumber "$3"}
--&MESG "Power Input B Fail on PM801RR in Slot $3 ($A)"
DESCRIPTION "Urgent power supply default is activated"
::= { pm801rrtraps 50 }
pm801rrPowerTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pm801rrAlmDefFuseB, pm801rrAlmDefFuseA , pm801rrtrapBoardNumber}
STATUS current
--&FILTNAME "PM801RR Fuse A&B Fail OFF"
--&ACTIONS { log, normal}
--&CLEARS { "PM801RR Fuse A Fail ON", "PM801RR Fuse B Fail ON" }
--&MATCH { pm801rrAlmDefFuseB "on", pm801rrAlmDefFuseA "on", pm801rrtrapBoardNumber "$3"}
--&MESG "Power Inputs A and B Present on PM801RR in Slot $3 ($A)"
DESCRIPTION "Urgent power supply default disappeared"
::= { pm801rrtraps 51 }
END