Observium_CE/mibs/bintec/BIANCA-BRICK-CAPI-MIB

1034 lines
31 KiB
Plaintext

-- This file is corresponding to Release 9.1.10.101 from 2014/08/11 00:00:00
-- (C)opyright 1991-2014 bintec elmeg GmbH, All Rights Reserved
-- $RCSfile: mibcapi,v $
-- $Revision: 1.28 $
BIANCA-BRICK-CAPI-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter, enterprises
FROM RFC1155-SMI
DisplayString
FROM RFC1158-MIB
BitValue, HexValue
FROM BINTEC-MIB
OBJECT-TYPE
FROM RFC-1212;
bintec OBJECT IDENTIFIER ::= { enterprises 272 }
bibo OBJECT IDENTIFIER ::= { bintec 4 }
capi OBJECT IDENTIFIER
::= { bibo 7 }
-- CAPI Group
-- Management Information for the CAPI Subsystem of the BIANCA/BRICK
capiApplTable OBJECT-TYPE
SYNTAX SEQUENCE OF CapiApplEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The capiApplTable contains information for all currently
registered CAPI 1.1 and CAPI 2.0 applications, and their
respective CAPI_REGISTER information.
Creating entries: Entries are created automatically by
the system. After receiving an appropriate
CAPI_REGISTER call, the system 'registers' the
application, and assigns it a unique capiApplNumber.
Deleting entries: Once an application releases, entries
are automatically removed by the system."
::= { capi 1 }
capiApplEntry OBJECT-TYPE
SYNTAX CapiApplEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { capiApplNumber }
::= { capiApplTable 1 }
CapiApplEntry ::=
SEQUENCE {
capiApplNumber INTEGER,
capiApplVersion INTEGER,
capiApplByteOrder INTEGER,
capiApplRegMsgCnt INTEGER,
capiApplRegLevel3Cnt INTEGER,
capiApplRegDblkCnt INTEGER,
capiApplRegDblkSize INTEGER,
capiApplInfoStr DisplayString
}
capiApplNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identification number of the registered application."
::= { capiApplEntry 1 }
capiApplVersion OBJECT-TYPE
SYNTAX INTEGER { capi11(1), capi20(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version number of the registered application."
DEFVAL { capi20 }
::= { capiApplEntry 2 }
capiApplByteOrder OBJECT-TYPE
SYNTAX INTEGER {
little-endian(1),
big-endian(2),
undef(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The byte order used by the application."
DEFVAL { little-endian }
::= { capiApplEntry 3 }
capiApplRegLevel3Cnt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CAPI_REGISTER: The number of level 3 connections
this application accepts."
::= { capiApplEntry 4 }
capiApplRegMsgCnt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CAPI_REGISTER: The number of registered CAPI
messages this application accepts."
::= { capiApplEntry 5 }
capiApplRegDblkCnt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CAPI_REGISTER: The number of registered B3 data
blocks this application accepts."
::= { capiApplEntry 6 }
capiApplRegDblkSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CAPI_REGISTER: The size of registered B3 data
blocks this application accepts."
::= { capiApplEntry 7 }
capiApplInfoStr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Information string of CAPI instance: IP address and TCP port
of connecting system and user name if any."
::= { capiApplEntry 8 }
capiListenTable OBJECT-TYPE
SYNTAX SEQUENCE OF CapiListenEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The capiListenTable contains the listen settings for each
CAPI application.
Creating entries: Entries can only be created by the
system and is performed automatically upon receiving a
CAPI_LISTEN_REQ message.
Deleting entries: Entries are automatically removed
by the system once the application releases."
::= { capi 2 }
capiListenEntry OBJECT-TYPE
SYNTAX CapiListenEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { capiListenApplication }
::= { capiListenTable 1 }
CapiListenEntry ::=
SEQUENCE {
capiListenApplication INTEGER,
capiListenController HexValue,
capiListenServiceMask HexValue,
capiListenEazMask HexValue,
capiListenInfoMask HexValue,
capiListenCipMask HexValue,
capiListenCipMask2 HexValue
}
capiListenApplication OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The application-number (capiApplNumber)."
::= { capiListenEntry 1 }
capiListenController OBJECT-TYPE
SYNTAX HexValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ISDN controller number. This value refers to the
isdnStkNumber."
::= { capiListenEntry 2 }
capiListenServiceMask OBJECT-TYPE
SYNTAX HexValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The bit mask of CAPI 1.1 listen services. Specifies
which 1TR6 services to listen for (CAPI 1.1 only)."
::= { capiListenEntry 3 }
capiListenEazMask OBJECT-TYPE
SYNTAX HexValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The bit mask of CAPI 1.1 listen-EAZs (CAPI 1.1 only)."
::= { capiListenEntry 4 }
capiListenInfoMask OBJECT-TYPE
SYNTAX HexValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The bit mask of the CAPI 1.1/2.0 listen InfoMask setting.
The purpose of infomask is to specify the type of
information for a physical connection or controller which
will be provided by CAPI."
::= { capiListenEntry 5 }
capiListenCipMask OBJECT-TYPE
SYNTAX HexValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The bit mask of CAPI 2.0 listen CIPMask. The purpose
of the CIPMask parameter is to select basic classes of
incoming calls. CAPI 2.0 applications only."
::= { capiListenEntry 6 }
capiListenCipMask2 OBJECT-TYPE
SYNTAX HexValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The bit mask of CAPI 2.0 listen CIPMask."
::= { capiListenEntry 7 }
capiPlciTable OBJECT-TYPE
SYNTAX SEQUENCE OF CapiPlciEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The capiPlciTable contains information for each currently
connected CAPI application (i.e. has a Physical Link
Connection Identifier associated with it).
Creating entries: Entries can only be made by the
system. Upon receiving a CAPI_CONNECT_REQ (or
CAPI_CONNECT_IND) message, the system assigns a
unique PLCI (capiPlciNumber) and an entry is made.
Deleting entries: Entries are automatically deleted by
the system once a CAPI_DISCONNECT_RESP message
is received."
::= { capi 3 }
capiPlciEntry OBJECT-TYPE
SYNTAX CapiPlciEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { capiPlciNumber }
::= { capiPlciTable 1 }
CapiPlciEntry ::=
SEQUENCE {
capiPlciNumber HexValue,
capiPlciApplication INTEGER,
capiPlciController HexValue,
capiPlciState INTEGER,
capiPlciSelectB2Proto INTEGER,
capiPlciSelectB2Dlpd OCTET STRING,
capiPlciSelectB3Proto INTEGER,
capiPlciSelectB3Ncpd OCTET STRING,
capiPlciB1Proto INTEGER,
capiPlciB1Config OCTET STRING,
capiPlciB2Proto INTEGER,
capiPlciB2Config OCTET STRING,
capiPlciB3Proto INTEGER,
capiPlciB3Config OCTET STRING,
capiPlciInfoMask HexValue,
capiPlciCipValue INTEGER
}
capiPlciNumber OBJECT-TYPE
SYNTAX HexValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The PLCI (physical link connection identifier) of the
application."
::= { capiPlciEntry 1 }
capiPlciApplication OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The application-number (capiApplNumber)."
::= { capiPlciEntry 2 }
capiPlciController OBJECT-TYPE
SYNTAX HexValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ISDN controller number. This value refers to the
isdnStkNumber."
::= { capiPlciEntry 3 }
capiPlciState OBJECT-TYPE
SYNTAX INTEGER {
p-0(1), p-1(2), p-2(3),
p-3(4), p-4(5), p-5(6),
p-6(7), p-7(8), p-act(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current link state as described in the CAPI state
diagram."
DEFVAL { p-0 }
::= { capiPlciEntry 4 }
capiPlciSelectB2Proto OBJECT-TYPE
SYNTAX INTEGER {
undef(1),
x75(2), hdlccrc(3), trans(4),
sdlc(5), x75btx(6), fax(7), lapd(8),
v110trans(9), v110sdlc(10), v110x75(11),
txonly(12), modem(241), v110sync(242)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current B2 protocol setting (CAPI 1.1 applications
only)."
DEFVAL { undef }
::= { capiPlciEntry 5 }
capiPlciSelectB2Dlpd OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current B2 protocol descriptor. DLPD = data link
protocol descriptor (CAPI 1.1 applications only)."
::= { capiPlciEntry 6 }
capiPlciSelectB3Proto OBJECT-TYPE
SYNTAX INTEGER {
undef(1),
t70nl(2), iso8208(3), t90(4),
trans(5), t30(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current B3 protocol setting (CAPI 1.1 applications
only)."
DEFVAL { undef }
::= { capiPlciEntry 7 }
capiPlciSelectB3Ncpd OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current B3 Ncpd setting. NCPD = network control
protocol descriptor (CAPI 1.1 applications only)."
::= { capiPlciEntry 8 }
capiPlciB1Proto OBJECT-TYPE
SYNTAX INTEGER {
undef(1),
hdlc(2), trans(3), v110trans(4),
v110hdlc(5), faxg3(6), hdlcinv(7),
hdlc56(8), modemneg(9), modemasync(10),
modemsync(11)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current CAPI 2.0 B1 protocol setting."
DEFVAL { undef }
::= { capiPlciEntry 9 }
capiPlciB1Config OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current CAPI 2.0 B1 protocol configuration setting."
::= { capiPlciEntry 10 }
capiPlciB2Proto OBJECT-TYPE
SYNTAX INTEGER {
undef(1),
x75(2), trans(3), sdlc(4),
lapd(5), t30(6), ppp(7),
transerr(8), modem(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current CAPI 2.0 B2 protocol setting."
DEFVAL { undef }
::= { capiPlciEntry 11 }
capiPlciB2Config OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current CAPI 2.0 B2 protocol configuration setting."
::= { capiPlciEntry 12 }
capiPlciB3Proto OBJECT-TYPE
SYNTAX INTEGER {
undef(1),
trans(2), t90(3), iso8208(4),
x25dce(5), t30(6), t30ext(7),
modem(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current CAPI 2.0 B3 protocol setting."
DEFVAL { undef }
::= { capiPlciEntry 13 }
capiPlciB3Config OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current CAPI 2.0 B3 protocol configuration setting."
::= { capiPlciEntry 14 }
capiPlciCipValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current CIPValue setting."
::= { capiPlciEntry 15 }
capiPlciInfoMask OBJECT-TYPE
SYNTAX HexValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current InfoMask setting."
::= { capiPlciEntry 16 }
capiNcciTable OBJECT-TYPE
SYNTAX SEQUENCE OF CapiNcciEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The capiNcciTable contains information for each CAPI
NCCI (network control connection identifier). An NCCI
describes a logical connection on level 3. Several NCCIs
operating on the same PLCI may exist.
Creating entries: As soon as a CAPI_CONNECT_B3_REQ
(or CAPI_CONNECT_B3_IND) message is received,
the system creates an entry by assigning the
application a unique capiNcciNumber.
Deleting entries: Entries are automatically deleted by
the system once a CAPI_DISCONNECT_B3_RESP
message is received."
::= { capi 4 }
capiNcciEntry OBJECT-TYPE
SYNTAX CapiNcciEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { capiNcciNumber }
::= { capiNcciTable 1 }
CapiNcciEntry ::=
SEQUENCE {
capiNcciNumber HexValue,
capiNcciApplication INTEGER,
capiNcciPlci HexValue,
capiNcciState INTEGER
}
capiNcciNumber OBJECT-TYPE
SYNTAX HexValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The NCCI number assigned by the system."
::= { capiNcciEntry 1 }
capiNcciApplication OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The application number (capiApplNumber)."
::= { capiNcciEntry 2 }
capiNcciPlci OBJECT-TYPE
SYNTAX HexValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The CAPI PLCI number (capiPlciNumber)."
::= { capiNcciEntry 3 }
capiNcciState OBJECT-TYPE
SYNTAX INTEGER {
n-0(1), n-1(2), n-2(3),
n-3(4), n-4(5), n-5(6),
n-act(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current state of the NCCI, as described in the
CAPI state diagram."
DEFVAL { n-0 }
::= { capiNcciEntry 4 }
capiInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF CapiInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The capiInfoTable contains the last 10 CAPI info codes
and their message identifiers for where the error occured.
The most recent message is at inx 09 with older messages
rolling off the top of the table, i.e. inx 00.
Creating entries: Entries are created automatically by
the system once a CAPI info code is received by a
registered application.
Deleting entries: Entries are removed automatically
by the system."
::= { capi 5 }
capiInfoEntry OBJECT-TYPE
SYNTAX CapiInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { capiInfoApplication }
::= { capiInfoTable 1 }
CapiInfoEntry ::=
SEQUENCE {
capiInfoApplication INTEGER,
capiInfoPlci HexValue,
capiInfoNcci HexValue,
capiInfoC1Command INTEGER,
capiInfoC2Command INTEGER,
capiInfoSubCommand INTEGER,
capiInfoNumber HexValue
}
capiInfoApplication OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The application number (capiApplNumber)."
::= { capiInfoEntry 1 }
capiInfoPlci OBJECT-TYPE
SYNTAX HexValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The CAPI PLCI number (capiPlciNumber)."
::= { capiInfoEntry 2 }
capiInfoNcci OBJECT-TYPE
SYNTAX HexValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The NCCI number (capiNcciNumber)."
::= { capiInfoEntry 3 }
capiInfoC1Command OBJECT-TYPE
SYNTAX INTEGER {
resetb3(1), connect(2), conact(3),
disc(4), listen(5), param(6),
info(7), data(8), conninfo(9),
dtmf(10), selb2(64), selb3(128),
listenb3(129), conb3(130), conb3act(131),
discb3(132), b3param(133), datab3(134),
handset(135)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The CAPI 1.1 command where the info occurred."
DEFVAL { info }
::= { capiInfoEntry 4 }
capiInfoC2Command OBJECT-TYPE
SYNTAX INTEGER {
alert(1), connect(2), conact(3),
disc(4), listen(5), info(8),
selectb(65), facility(128), conb3(130),
conb3act(131), discb3(132), datab3(134),
resetb3(135), conb3t90(136), manufact(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The CAPI 2.0 command where the info occurred."
DEFVAL { info }
::= { capiInfoEntry 5 }
capiInfoSubCommand OBJECT-TYPE
SYNTAX INTEGER {
req(1), conf(2), ind(3), resp(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The CAPI 1.1/2.0 subcommand."
DEFVAL { ind }
::= { capiInfoEntry 6 }
capiInfoNumber OBJECT-TYPE
SYNTAX HexValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The info value as specified in the CAPI 1.1/2.0
specification. See the Software Reference Manual for a
listing of CAPI 1.1 and CAPI 2.0 info values."
::= { capiInfoEntry 7 }
capiConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF CapiConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The capiConfigTable contains configuration information
for each ISDN stack. Setting these fields is optional, and
is not required.
Creating entries: Entries are created automatically by
the system when a new ISDN stack is initialised in the
isdnStkTable.
Deleting entries: An entry can be removed by assigning
the value `delete' to its capiConfigFaxG3RcvSpeed object.
It can be removed only if there is no entry with it's
capiConfigStkNumber in the isdnStkTable."
::= { capi 6 }
capiConfigEntry OBJECT-TYPE
SYNTAX CapiConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { capiConfigStkNumber }
::= { capiConfigTable 1 }
CapiConfigEntry ::=
SEQUENCE {
capiConfigStkNumber INTEGER,
capiConfigFaxG3RcvSpeed INTEGER,
capiConfigFaxG3ECM INTEGER,
capiConfigFaxG3Header INTEGER,
capiConfigVoiceCoding INTEGER,
capiConfigSendAlerting INTEGER,
capiConfigV42bis INTEGER,
capiConfigModemDefault INTEGER,
capiConfigFaxModulation INTEGER,
capiConfigFax12000 INTEGER,
capiConfigFaxTXLevel INTEGER
}
capiConfigStkNumber OBJECT-TYPE
SYNTAX INTEGER (0..31)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The isdnStkNumber this configuration belongs to."
::= { capiConfigEntry 1 }
capiConfigFaxG3RcvSpeed OBJECT-TYPE
SYNTAX INTEGER {
r4800(1), r7200(2), r9600(3), r14400(4), maximum(5),
not-available(6), delete(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The G3 facsimile receive speed. For CM-EBRI this
should be set to maximum.
Set this field to `delete' to remove this entry.
The entry can be deleted only if there is no entry
with it's capiConfigStkNumber in the isdnStkTable."
DEFVAL { maximum }
::= { capiConfigEntry 2 }
capiConfigFaxG3ECM OBJECT-TYPE
SYNTAX INTEGER { on(1), off(2), not-available(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies whether ECM (error correction mode)
should be used for G3 facsimile transmissions."
DEFVAL { on }
::= { capiConfigEntry 3 }
capiConfigFaxG3Header OBJECT-TYPE
SYNTAX INTEGER {
logo-header(1), no-logo(2), no-header(3), not-available(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies whether the header-line and logo
('BIANCA/FAX'), should appear on outgoing facsimiles. The
value 'logo_header' allows the header-line and the logo
to be printed on the top of each page."
DEFVAL { logo-header }
::= { capiConfigEntry 4 }
capiConfigVoiceCoding OBJECT-TYPE
SYNTAX INTEGER { normal(1), reverse(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Switches the bit order for voice-data."
DEFVAL { reverse }
::= { capiConfigEntry 5 }
capiConfigSendAlerting OBJECT-TYPE
SYNTAX INTEGER { never(1), ever(2), voice-only(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"For CAPI 1.1 this specifies when the CAPI server
should send alert messages for incoming calls."
DEFVAL { voice-only }
::= { capiConfigEntry 6 }
capiConfigV42bis OBJECT-TYPE
SYNTAX INTEGER { on(1), off(2), not-available(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies whether V.42bis data compression should be
used. If data compression is activated here,the receiving
or sending side is first queried whether it supports data
compression. The BRICK supports V.42bis data
compression using up to 2 B-channels."
DEFVAL { off }
::= { capiConfigEntry 7 }
capiConfigModemDefault OBJECT-TYPE
SYNTAX INTEGER { modem-profile-1(1), modem-profile-2(2),
modem-profile-3(3), modem-profile-4(4),
modem-profile-5(5), modem-profile-6(6),
modem-profile-7(7), modem-profile-8(8)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the modem profile of the mdmProfileTable
which contains the default modem parameters to use
for modem connections."
DEFVAL { modem-profile-1 }
::= { capiConfigEntry 8 }
capiConfigFaxModulation OBJECT-TYPE
SYNTAX INTEGER { v17(1), v33(2), v29(3), v17s(5), v33s(6) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set the default transmission protocol for fax.
- v17 max. 14400 Bps new standard
- v33 max. 14000 Bps early standard
- v29 max. 9600 Bps fax standard
- v17s v17 with Swiss capability
- v33s v33 with Swiss capability"
DEFVAL { v17 }
::= { capiConfigEntry 9 }
capiConfigFax12000 OBJECT-TYPE
SYNTAX INTEGER { on(1), off(2)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable the 12000Bps Mode for fax transmission.
A lot of fax receivers have problems with this tranmission
mode. Default value is off"
DEFVAL { off }
::= { capiConfigEntry 10 }
capiConfigFaxTXLevel OBJECT-TYPE
SYNTAX INTEGER { db0(1), db3(2),db6(3),db9(4),db12(5),db15(6)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set the transmit level to -x dB db0 = 0dB, db3 = -3dB.
In Germany -6dB (db6) is normally used for facsimile
transmission."
DEFVAL { db6 }
::= { capiConfigEntry 11 }
capiMultiControllerTable OBJECT-TYPE
SYNTAX SEQUENCE OF CapiMultiControllerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains mappings between controller numbers
used by CAPI applications and the ISDN stacks available on
the BRICK (i.e., the Number field of the isdnStkTable).
The Version field specifies whether an entry applies to
CAPI 1.1 or CAPI 2.0 applications.
If a CAPI 1.1 entry is not defined, CAPI 1.1 applications
can only use isdnStkNumber N if N is the controller number
requested by the application.
If a CAPI 2.0 entry is not defined, CAPI 2.0 applications
can only use isdnStkNumber N-1 if N is the controller number
requested by the application.
Creating entries: Entries are created by assigning a
value to the capiControllerNumber object.
Deleting entries: An entry can be removed by assigning
the value `delete' to its capiControllerVersion object."
::= { capi 7 }
capiMultiControllerEntry OBJECT-TYPE
SYNTAX CapiMultiControllerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { capiControllerNumber }
::= { capiMultiControllerTable 1 }
CapiMultiControllerEntry ::=
SEQUENCE {
capiControllerNumber INTEGER,
capiControllerStkMask BitValue,
capiControllerVersion INTEGER
}
capiControllerNumber OBJECT-TYPE
SYNTAX INTEGER (0..31)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The controller number requested by the CAPI application."
::= { capiMultiControllerEntry 1 }
capiControllerStkMask OBJECT-TYPE
SYNTAX BitValue
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This binary number defines the ISDN stack(s) to use for
the specified CAPI 1.1 or CAPI 2.0 applications.
For example; `Number=1 StkMask=0b1111 Version=capi20' means:
allow CAPI 2.0 applications requesting ISDN controller 1 to
use the ISDN stacks with IsdnStkNumber 0 - 3 on the BRICK."
-- DEFVAL { 'FFFFFFFF'H }
DEFVAL { 4294967295 }
::= { capiMultiControllerEntry 2 }
capiControllerVersion OBJECT-TYPE
SYNTAX INTEGER { capi11(1), capi20(2), delete(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies which CAPI applications (CAPI version 1.1, or 2.0)
this entry applies to.
Set this field to `delete' to delete this entry."
DEFVAL { capi11 }
::= { capiMultiControllerEntry 3 }
capiAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable CAPI"
DEFVAL { enable }
::= { capi 9 }
capiTcpNoDelay OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or Disable TCP Nagle Algorithm for CAPI.
disable: Normal operation with Nagle support.
enable : Disable Nagle TCP Algorithm.
Enable TcpNoDelay increases Network load and decrease
delay of TCP packages. On CAPI Applications with small
Data packages this option may increase transmission rate."
DEFVAL { disable }
::= { capi 10 }
capiFaxG3Header OBJECT-TYPE
SYNTAX INTEGER {
logo-header(1),
no-logo(2),
no-header(3),
not-available(4),
specify(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies whether the header-line and logo
('BIANCA/FAX'), should appear on outgoing facsimiles. The
value 'logo_header' allows the header-line and the logo
to be printed on the top of each page."
DEFVAL { specify }
::= { capi 11 }
capiX25DefWinSize OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the X.25 default Windowsize used in
ISO8208 (X.25 DTE <-> DTE) Filetransferprotocol.
Applications such as OFTP normally uses 7 but
some Applications did not use X.25 negotiation,
so the CAPI uses here a default from 2 and the
connection is closed by a X.25 Reset. Setting
this value to 7 is not standard but useful for
the customer to avoid this error."
DEFVAL { 2 }
::= { capi 12 }
END