Observium_CE/mibs/tplink/TPLINK-ETHERNETOAMLINKMONCFG-MIB

89 lines
2.9 KiB
Plaintext

TPLINK-ETHERNETOAMLINKMONCFG-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE,Unsigned32 FROM SNMPv2-SMI
ethernetOamLinkMonConfig FROM TPLINK-ETHERNETOAM-MIB
DisplayString
FROM SNMPv2-TC
ifIndex
FROM RFC1213-MIB;
ethernetOamLinkMonCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthernetOamLinkMonCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains link monitoring configuration of each port.
Through link monitoring, you can detect and find faults in various environments at the data link layer.
Link monitoring uses event notification PDUs. When a link event occurs, the local link notifies the OAM entity of the event."
::= {ethernetOamLinkMonConfig 1}
ethernetOamLinkMonCfgEntry OBJECT-TYPE
SYNTAX EthernetOamLinkMonCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry that contains the link monitoring configuration of each port."
INDEX {ifIndex, ethernetOamLinkMonCfgEvent}
::= {ethernetOamLinkMonCfgTable 1}
EthernetOamLinkMonCfgEntry ::=
SEQUENCE
{
ethernetOamLinkMonCfgPort DisplayString,
ethernetOamLinkMonCfgEvent INTEGER,
ethernetOamLinkMonCfgThreshold Unsigned32,
ethernetOamLinkMonCfgWindow Unsigned32,
ethernetOamLinkMonCfgNotify INTEGER,
ethernetOamLinkMonCfgLAG OCTET STRING(SIZE(0..10))
}
ethernetOamLinkMonCfgPort OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the port number."
::= {ethernetOamLinkMonCfgEntry 1}
ethernetOamLinkMonCfgEvent OBJECT-TYPE
SYNTAX INTEGER {symbol-period(1), frame(2), frame-period(3), frame-seconds(4)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Select various types of link monitoring."
::= {ethernetOamLinkMonCfgEntry 2}
ethernetOamLinkMonCfgThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enter the number of errors that is required to be equal to or greater than in order for the event to be generated."
::= {ethernetOamLinkMonCfgEntry 3}
ethernetOamLinkMonCfgWindow OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enter the period of the event. The unit is 100ms for symbol-period, frame, frame-seconds link event and 1 frame for frame-period link event."
::= {ethernetOamLinkMonCfgEntry 4}
ethernetOamLinkMonCfgNotify OBJECT-TYPE
SYNTAX INTEGER {disable(0),enable(1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select to enable or disable the event notification."
::= {ethernetOamLinkMonCfgEntry 5}
ethernetOamLinkMonCfgLAG OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the LAG number of the port."
::= {ethernetOamLinkMonCfgEntry 6}
END