POWER-ATTRIBUTES-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
mib-2,
|
|
Integer32, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
UnitMultiplier
|
|
FROM ENERGY-OBJECT-MIB
|
|
entPhysicalIndex
|
|
FROM ENTITY-MIB;
|
|
|
|
powerAttributesMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201502090000Z" -- 9 February 2015
|
|
ORGANIZATION "IETF EMAN Working Group"
|
|
CONTACT-INFO
|
|
"WG charter:
|
|
http://datatracker.ietf.org/wg/eman/charter/
|
|
|
|
Mailing Lists:
|
|
General Discussion: eman@ietf.org
|
|
|
|
To Subscribe:
|
|
https://www.ietf.org/mailman/listinfo/eman
|
|
|
|
Archive:
|
|
http://www.ietf.org/mail-archive/web/eman
|
|
|
|
Editors:
|
|
|
|
Mouli Chandramouli
|
|
Cisco Systems, Inc.
|
|
Sarjapur Outer Ring Road
|
|
Bangalore 560103
|
|
India
|
|
Phone: +91 80 4429 2409
|
|
Email: moulchan@cisco.com
|
|
|
|
Brad Schoening
|
|
44 Rivers Edge Drive
|
|
Little Silver, NJ 07739
|
|
United States
|
|
Email: brad.schoening@verizon.net
|
|
|
|
Juergen Quittek
|
|
NEC Europe Ltd.
|
|
NEC Laboratories Europe
|
|
Network Research Division
|
|
Kurfuersten-Anlage 36
|
|
Heidelberg 69115
|
|
Germany
|
|
Phone: +49 6221 4342-115
|
|
Email: quittek@neclab.eu
|
|
|
|
Thomas Dietz
|
|
NEC Europe Ltd.
|
|
NEC Laboratories Europe
|
|
Network Research Division
|
|
Kurfuersten-Anlage 36
|
|
69115 Heidelberg
|
|
Germany
|
|
Phone: +49 6221 4342-128
|
|
Email: Thomas.Dietz@nw.neclab.eu
|
|
|
|
Benoit Claise
|
|
Cisco Systems, Inc.
|
|
De Kleetlaan 6a b1
|
|
Degem 1831
|
|
Belgium
|
|
Phone: +32 2 704 5622
|
|
Email: bclaise@cisco.com"
|
|
DESCRIPTION
|
|
"Copyright (c) 2015 IETF Trust and the persons identified as
|
|
authors of the code. All rights reserved.
|
|
|
|
Redistribution and use in source and binary forms, with or
|
|
without modification, is permitted pursuant to, and subject
|
|
to the license terms contained in, the Simplified BSD License
|
|
set forth in Section 4.c of the IETF Trust's Legal Provisions
|
|
Relating to IETF Documents
|
|
(http://trustee.ietf.org/license-info).
|
|
|
|
This MIB is used to report AC power attributes in devices.
|
|
The table is a sparse augmentation of the eoPowerTable table
|
|
from the energyObjectMib module. Both three-phase and
|
|
single-phase power configurations are supported.
|
|
|
|
As a requirement for this MIB module, RFC 7461 SHOULD be
|
|
implemented.
|
|
|
|
Module Compliance of ENTITY-MIB v4 with respect to
|
|
entity4CRCompliance MUST be supported which requires
|
|
implementation of four MIB objects: entPhysicalIndex,
|
|
entPhysicalClass, entPhysicalName, and entPhysicalUUID."
|
|
REVISION "201502090000Z" -- 9 February 2015
|
|
DESCRIPTION
|
|
"Initial version, published as RFC 7460"
|
|
::= { mib-2 230 }
|
|
|
|
powerAttributesMIBConform OBJECT IDENTIFIER
|
|
::= { powerAttributesMIB 0 }
|
|
|
|
powerAttributesMIBObjects OBJECT IDENTIFIER
|
|
::= { powerAttributesMIB 1 }
|
|
|
|
-- Objects
|
|
|
|
eoACPwrAttributesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EoACPwrAttributesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains power attributes measurements for
|
|
supported entPhysicalIndex entities. It is a sparse
|
|
extension of the eoPowerTable."
|
|
::= { powerAttributesMIBObjects 1 }
|
|
|
|
eoACPwrAttributesEntry OBJECT-TYPE
|
|
SYNTAX EoACPwrAttributesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a sparse extension of the eoPowerTable with
|
|
entries for power attributes measurements or
|
|
configuration. Each measured value corresponds to an
|
|
attribute in IEC 61850-7-4 for non-phase measurements
|
|
within the object MMXN."
|
|
INDEX { entPhysicalIndex }
|
|
::= { eoACPwrAttributesTable 1 }
|
|
|
|
EoACPwrAttributesEntry ::= SEQUENCE {
|
|
eoACPwrAttributesConfiguration INTEGER,
|
|
eoACPwrAttributesAvgVoltage Integer32,
|
|
eoACPwrAttributesAvgCurrent Unsigned32,
|
|
eoACPwrAttributesFrequency Integer32,
|
|
eoACPwrAttributesPowerUnitMultiplier UnitMultiplier,
|
|
eoACPwrAttributesPowerAccuracy Integer32,
|
|
eoACPwrAttributesTotalActivePower Integer32,
|
|
eoACPwrAttributesTotalReactivePower Integer32,
|
|
eoACPwrAttributesTotalApparentPower Integer32,
|
|
eoACPwrAttributesTotalPowerFactor Integer32,
|
|
eoACPwrAttributesThdCurrent Integer32,
|
|
eoACPwrAttributesThdVoltage Integer32
|
|
}
|
|
|
|
eoACPwrAttributesConfiguration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sngl(1),
|
|
del(2),
|
|
wye(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration describes the physical configurations of
|
|
the power supply lines:
|
|
|
|
* alternating current, single phase (SNGL)
|
|
* alternating current, three-phase delta (DEL)
|
|
* alternating current, three-phase Y (WYE)
|
|
|
|
Three-phase configurations can be either connected in a
|
|
triangular delta (DEL) or star Y (WYE) system. WYE
|
|
systems have a shared neutral voltage, while DEL systems
|
|
do not. Each phase is offset 120 degrees to each other."
|
|
::= { eoACPwrAttributesEntry 1 }
|
|
|
|
eoACPwrAttributesAvgVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Volt AC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A measured value for average of the voltage measured
|
|
over an integral number of AC cycles. For a three-phase
|
|
system, this is the average voltage (V1+V2+V3)/3. IEC
|
|
61850-7-4 measured value attribute 'Vol'."
|
|
::= { eoACPwrAttributesEntry 2 }
|
|
|
|
eoACPwrAttributesAvgCurrent OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "amperes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A measured value for average of the current measured
|
|
over an integral number of AC cycles. For a three-phase
|
|
system, this is the average current (I1+I2+I3)/3. IEC
|
|
61850-7-4 attribute 'Amp'."
|
|
::= { eoACPwrAttributesEntry 3 }
|
|
|
|
eoACPwrAttributesFrequency OBJECT-TYPE
|
|
SYNTAX Integer32 (4500..6500)
|
|
UNITS "0.01 hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A measured value for the basic frequency of the AC
|
|
circuit. IEC 61850-7-4 attribute 'Hz'."
|
|
::= { eoACPwrAttributesEntry 4 }
|
|
|
|
eoACPwrAttributesPowerUnitMultiplier OBJECT-TYPE
|
|
SYNTAX UnitMultiplier
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of watts for the usage value in
|
|
eoACPwrAttributesTotalActivePower,
|
|
eoACPwrAttributesTotalReactivePower,
|
|
and eoACPwrAttributesTotalApparentPower measurements.
|
|
For three-phase power systems, this will also include
|
|
eoACPwrAttributesWyeActivePower,
|
|
eoACPwrAttributesWyeReactivePower, and
|
|
eoACPwrAttributesWyeApparentPower."
|
|
::= { eoACPwrAttributesEntry 5 }
|
|
|
|
eoACPwrAttributesPowerAccuracy OBJECT-TYPE
|
|
SYNTAX Integer32 (0..10000)
|
|
UNITS "hundredths of percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a percentage value, in hundredths of a
|
|
percent, representing the presumed accuracy of active,
|
|
reactive, and apparent power usage reporting. For
|
|
example, 1010 means the reported usage is accurate to +/-
|
|
10.1 percent. This value is zero if the accuracy is
|
|
unknown.
|
|
|
|
ANSI and IEC define the following accuracy classes for
|
|
power measurement: IEC 62053-22 & 60044-1 class 0.1, 0.2,
|
|
0.5, 1, & 3.
|
|
ANSI C12.20 class 0.2 & 0.5"
|
|
::= { eoACPwrAttributesEntry 6 }
|
|
|
|
eoACPwrAttributesTotalActivePower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A measured value of the actual power delivered to or
|
|
consumed by the load. IEC 61850-7-4 attribute 'TotW'."
|
|
::= { eoACPwrAttributesEntry 7 }
|
|
|
|
eoACPwrAttributesTotalReactivePower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "volt-amperes reactive"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A measured value of the reactive portion of the apparent
|
|
power. IEC 61850-7-4 attribute 'TotVAr'."
|
|
::= { eoACPwrAttributesEntry 8 }
|
|
|
|
eoACPwrAttributesTotalApparentPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "volt-amperes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A measured value of the voltage and current that
|
|
determines the apparent power. The apparent power is the
|
|
vector sum of real and reactive power.
|
|
|
|
Note: watts and volt-amperes are equivalent units and may
|
|
be combined. IEC 61850-7-4 attribute 'TotVA'."
|
|
::= { eoACPwrAttributesEntry 9 }
|
|
|
|
eoACPwrAttributesTotalPowerFactor OBJECT-TYPE
|
|
SYNTAX Integer32 (-10000..10000)
|
|
UNITS "hundredths"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A measured value ratio of the real power flowing to the
|
|
load versus the apparent power. It is dimensionless and
|
|
expressed here as a percentage value in hundredths. A power
|
|
factor of 100% indicates there is no inductance load and
|
|
thus no reactive power. A Power Factor can be positive or
|
|
negative, where the sign should be in lead/lag (IEEE)
|
|
form. IEC 61850-7-4 attribute 'TotPF'."
|
|
::= { eoACPwrAttributesEntry 10 }
|
|
|
|
eoACPwrAttributesThdCurrent OBJECT-TYPE
|
|
SYNTAX Integer32 (0..10000)
|
|
UNITS "hundredths of percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A calculated value for the current total harmonic
|
|
distortion (THD). Method of calculation is not
|
|
specified. IEC 61850-7-4 attribute 'ThdAmp'."
|
|
::= { eoACPwrAttributesEntry 11 }
|
|
|
|
eoACPwrAttributesThdVoltage OBJECT-TYPE
|
|
SYNTAX Integer32 (0..10000)
|
|
UNITS "hundredths of percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A calculated value for the voltage total harmonic
|
|
distortion (THD). The method of calculation is not
|
|
specified. IEC 61850-7-4 attribute 'ThdVol'."
|
|
::= { eoACPwrAttributesEntry 12 }
|
|
|
|
eoACPwrAttributesDelPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EoACPwrAttributesDelPhaseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This optional table describes three-phase power attributes
|
|
measurements in a DEL configuration with phase-to-phase
|
|
|
|
power attributes measurements. Entities having single
|
|
phase power shall not have any entities. This is a
|
|
sparse extension of the eoACPwrAttributesTable.
|
|
|
|
These attributes correspond to measurements related to
|
|
the IEC 61850-7.4 MMXU phase and measured harmonic or
|
|
interharmonics related to the MHAI phase."
|
|
::= { powerAttributesMIBObjects 2 }
|
|
|
|
eoACPwrAttributesDelPhaseEntry OBJECT-TYPE
|
|
SYNTAX EoACPwrAttributesDelPhaseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry describes power measurements of a phase in a
|
|
DEL three-phase power. Three entries are required for each
|
|
supported entPhysicalIndex entry. Voltage measurements
|
|
are provided relative to each other.
|
|
|
|
For phase-to-phase measurements, the
|
|
eoACPwrAttributesDelPhaseIndex is compared against the
|
|
following phase at +120 degrees. Thus, the possible
|
|
values are:
|
|
|
|
eoACPwrAttributesDelPhaseIndex Next Phase Angle
|
|
0 120
|
|
120 240
|
|
240 0
|
|
"
|
|
INDEX { entPhysicalIndex, eoACPwrAttributesDelPhaseIndex }
|
|
::= { eoACPwrAttributesDelPhaseTable 1}
|
|
|
|
EoACPwrAttributesDelPhaseEntry ::= SEQUENCE {
|
|
eoACPwrAttributesDelPhaseIndex Integer32,
|
|
eoACPwrAttributesDelPhaseToNextPhaseVoltage Integer32,
|
|
eoACPwrAttributesDelThdPhaseToNextPhaseVoltage Integer32
|
|
}
|
|
|
|
eoACPwrAttributesDelPhaseIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..359)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A phase angle typically corresponding to 0, 120, 240."
|
|
::= { eoACPwrAttributesDelPhaseEntry 1 }
|
|
|
|
eoACPwrAttributesDelPhaseToNextPhaseVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Volt AC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A measured value of phase to next phase voltages, where
|
|
the next phase is IEC 61850-7-4 attribute 'PPV'."
|
|
::= { eoACPwrAttributesDelPhaseEntry 2 }
|
|
|
|
eoACPwrAttributesDelThdPhaseToNextPhaseVoltage OBJECT-TYPE
|
|
SYNTAX Integer32 (0..10000)
|
|
UNITS "hundredths of percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A calculated value for the voltage total harmonic
|
|
distortion for phase to next phase. Method of calculation
|
|
is not specified. IEC 61850-7-4 attribute 'ThdPPV'."
|
|
::= { eoACPwrAttributesDelPhaseEntry 3 }
|
|
|
|
eoACPwrAttributesWyePhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EoACPwrAttributesWyePhaseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This optional table describes three-phase power attributes
|
|
measurements in a WYE configuration with phase-to-neutral
|
|
power attributes measurements. Entities having single
|
|
phase power shall not have any entities. This is a sparse
|
|
extension of the eoACPwrAttributesTable.
|
|
|
|
These attributes correspond to measurements related to
|
|
the IEC 61850-7.4 MMXU phase and measured harmonic or
|
|
interharmonics related to the MHAI phase."
|
|
::= { powerAttributesMIBObjects 3 }
|
|
|
|
eoACPwrAttributesWyePhaseEntry OBJECT-TYPE
|
|
SYNTAX EoACPwrAttributesWyePhaseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table describes measurements of a phase in a WYE
|
|
three-phase power system. Three entries are required for
|
|
each supported entPhysicalIndex entry. Voltage
|
|
measurements are relative to neutral.
|
|
|
|
Each entry describes power attributes of one phase of a
|
|
WYE three-phase power system."
|
|
INDEX { entPhysicalIndex, eoACPwrAttributesWyePhaseIndex }
|
|
::= { eoACPwrAttributesWyePhaseTable 1}
|
|
|
|
EoACPwrAttributesWyePhaseEntry ::= SEQUENCE {
|
|
eoACPwrAttributesWyePhaseIndex Integer32,
|
|
eoACPwrAttributesWyePhaseToNeutralVoltage Integer32,
|
|
eoACPwrAttributesWyeCurrent Integer32,
|
|
eoACPwrAttributesWyeActivePower Integer32,
|
|
eoACPwrAttributesWyeReactivePower Integer32,
|
|
eoACPwrAttributesWyeApparentPower Integer32,
|
|
eoACPwrAttributesWyePowerFactor Integer32,
|
|
eoACPwrAttributesWyeThdCurrent Integer32,
|
|
eoACPwrAttributesWyeThdPhaseToNeutralVoltage Integer32
|
|
}
|
|
|
|
eoACPwrAttributesWyePhaseIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..359)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A phase angle typically corresponding to 0, 120, 240."
|
|
::= { eoACPwrAttributesWyePhaseEntry 1 }
|
|
|
|
eoACPwrAttributesWyePhaseToNeutralVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Volt AC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A measured value of phase to neutral voltage. IEC
|
|
61850-7-4 attribute 'PNV'."
|
|
::= { eoACPwrAttributesWyePhaseEntry 2 }
|
|
|
|
eoACPwrAttributesWyeCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 amperes AC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A measured value of phase currents. IEC 61850-7-4
|
|
attribute 'A'."
|
|
::= { eoACPwrAttributesWyePhaseEntry 3 }
|
|
|
|
eoACPwrAttributesWyeActivePower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A measured value of the actual power delivered to or
|
|
consumed by the load with the magnitude indicated
|
|
separately in eoPowerUnitMultiplier. IEC 61850-7-4
|
|
attribute 'W'."
|
|
::= { eoACPwrAttributesWyePhaseEntry 4 }
|
|
|
|
eoACPwrAttributesWyeReactivePower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "volt-amperes reactive"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A measured value of the reactive portion of the apparent
|
|
power with the magnitude of indicated separately in
|
|
eoPowerUnitMultiplier. IEC 61850-7-4 attribute 'VAr'."
|
|
::= { eoACPwrAttributesWyePhaseEntry 5 }
|
|
|
|
eoACPwrAttributesWyeApparentPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "volt-amperes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A measured value of the voltage and current determines
|
|
the apparent power with the indicated separately in
|
|
eoPowerUnitMultiplier. Active plus reactive power equals
|
|
the total apparent power.
|
|
|
|
Note: Watts and volt-amperes are equivalent units and may
|
|
be combined. IEC 61850-7-4 attribute 'VA'."
|
|
::= { eoACPwrAttributesWyePhaseEntry 6 }
|
|
|
|
eoACPwrAttributesWyePowerFactor OBJECT-TYPE
|
|
SYNTAX Integer32 (-10000..10000)
|
|
UNITS "hundredths"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A measured value ratio of the real power flowing to the
|
|
load versus the apparent power for this phase. IEC
|
|
61850-7-4 attribute 'PF'. Power Factor can be positive or
|
|
negative where the sign should be in lead/lag (IEEE)
|
|
form."
|
|
::= { eoACPwrAttributesWyePhaseEntry 7 }
|
|
|
|
eoACPwrAttributesWyeThdCurrent OBJECT-TYPE
|
|
SYNTAX Integer32 (0..10000)
|
|
UNITS "hundredths of percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A calculated value for the voltage total harmonic
|
|
distortion (THD) for phase to phase. Method of
|
|
calculation is not specified.
|
|
IEC 61850-7-4 attribute 'ThdA'."
|
|
::= { eoACPwrAttributesWyePhaseEntry 8 }
|
|
|
|
eoACPwrAttributesWyeThdPhaseToNeutralVoltage OBJECT-TYPE
|
|
SYNTAX Integer32 (0..10000)
|
|
UNITS "hundredths of percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A calculated value of the voltage total harmonic
|
|
distortion (THD) for phase to neutral. IEC 61850-7-4
|
|
attribute 'ThdPhV'."
|
|
::= { eoACPwrAttributesWyePhaseEntry 9 }
|
|
|
|
-- Conformance
|
|
powerAttributesMIBCompliances OBJECT IDENTIFIER
|
|
::= { powerAttributesMIB 2 }
|
|
|
|
powerAttributesMIBGroups OBJECT IDENTIFIER
|
|
::= { powerAttributesMIB 3 }
|
|
|
|
powerAttributesMIBFullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When this MIB is implemented with support for read-
|
|
create, then such an implementation can claim full
|
|
compliance. Such devices can then be both monitored and
|
|
configured with this MIB.
|
|
|
|
Module Compliance of RFC 6933 with respect to
|
|
entity4CRCompliance MUST be supported which requires
|
|
implementation of four MIB objects: entPhysicalIndex,
|
|
entPhysicalClass, entPhysicalName, and entPhysicalUUID."
|
|
REFERENCE
|
|
"RFC 6933: Entity MIB (Version 4)"
|
|
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
powerACPwrAttributesMIBTableGroup
|
|
}
|
|
|
|
GROUP powerACPwrAttributesOptionalMIBTableGroup
|
|
DESCRIPTION
|
|
"A compliant implementation does not have
|
|
to implement."
|
|
|
|
GROUP powerACPwrAttributesDelPhaseMIBTableGroup
|
|
DESCRIPTION
|
|
"A compliant implementation does not have to implement."
|
|
|
|
GROUP powerACPwrAttributesWyePhaseMIBTableGroup
|
|
DESCRIPTION
|
|
"A compliant implementation does not have to implement."
|
|
::= { powerAttributesMIBCompliances 1 }
|
|
|
|
-- Units of Conformance
|
|
|
|
powerACPwrAttributesMIBTableGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
-- Note that object entPhysicalIndex is NOT
|
|
-- included since it is not-accessible
|
|
eoACPwrAttributesAvgVoltage,
|
|
eoACPwrAttributesAvgCurrent,
|
|
eoACPwrAttributesFrequency,
|
|
eoACPwrAttributesPowerUnitMultiplier,
|
|
eoACPwrAttributesPowerAccuracy,
|
|
eoACPwrAttributesTotalActivePower,
|
|
eoACPwrAttributesTotalReactivePower,
|
|
eoACPwrAttributesTotalApparentPower,
|
|
eoACPwrAttributesTotalPowerFactor
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This group contains the collection of all the power
|
|
attributes objects related to the Energy Object."
|
|
::= { powerAttributesMIBGroups 1 }
|
|
|
|
powerACPwrAttributesOptionalMIBTableGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
eoACPwrAttributesConfiguration,
|
|
eoACPwrAttributesThdCurrent,
|
|
eoACPwrAttributesThdVoltage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This group contains the collection of all the power
|
|
attributes objects related to the Energy Object."
|
|
::= { powerAttributesMIBGroups 2 }
|
|
|
|
powerACPwrAttributesDelPhaseMIBTableGroup OBJECT-GROUP
|
|
|
|
OBJECTS {
|
|
-- Note that object entPhysicalIndex and
|
|
-- eoACPwrAttributesDelPhaseIndex are NOT
|
|
-- included since they are not-accessible
|
|
eoACPwrAttributesDelPhaseToNextPhaseVoltage,
|
|
eoACPwrAttributesDelThdPhaseToNextPhaseVoltage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This group contains the collection of all power
|
|
attributes of a phase in a DEL three-phase power system."
|
|
::= { powerAttributesMIBGroups 3 }
|
|
|
|
powerACPwrAttributesWyePhaseMIBTableGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
-- Note that object entPhysicalIndex and
|
|
-- eoACPwrAttributesWyePhaseIndex are NOT
|
|
-- included since they are not-accessible
|
|
eoACPwrAttributesWyePhaseToNeutralVoltage,
|
|
eoACPwrAttributesWyeCurrent,
|
|
eoACPwrAttributesWyeActivePower,
|
|
eoACPwrAttributesWyeReactivePower,
|
|
eoACPwrAttributesWyeApparentPower,
|
|
eoACPwrAttributesWyePowerFactor,
|
|
eoACPwrAttributesWyeThdPhaseToNeutralVoltage,
|
|
eoACPwrAttributesWyeThdCurrent
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This group contains the collection of all power
|
|
attributes of a phase in a WYE three-phase power system."
|
|
::= { powerAttributesMIBGroups 4 }
|
|
|
|
END
|