RAD-ConfigChange-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
-- It is RAD's intent to encourage the widespread use of
|
|
-- this Specification in connection with the management of
|
|
-- RAD products. RAD grants vendors, end-users,
|
|
-- and other interested parties a non-exclusive license to
|
|
-- use this Specification in connection with the management
|
|
-- of RAD products.
|
|
|
|
-- This Specification is supplied "as is," and RAD makes
|
|
-- no warranty, either express or implied, as to the use,
|
|
-- operation, condition, or performance of the Specification.
|
|
|
|
|
|
IMPORTS
|
|
|
|
sysName FROM SNMPv2-MIB
|
|
Unsigned32, OBJECT-TYPE, MODULE-IDENTITY,
|
|
NOTIFICATION-TYPE FROM SNMPv2-SMI
|
|
systemsEvents FROM RAD-GEN-MIB
|
|
agnt FROM RAD-SMI-MIB;
|
|
|
|
|
|
agnConfigChange MODULE-IDENTITY
|
|
LAST-UPDATED "201502191800Z" -- February 19, 2015
|
|
ORGANIZATION "RAD Data Communications Ltd."
|
|
CONTACT-INFO
|
|
"System Department
|
|
|
|
Email: mibs@rad.com
|
|
Postal: RAD Data Communications Ltd.
|
|
24 Raoul Wallenberg St.
|
|
Tel-Aviv 6971920
|
|
Israel
|
|
|
|
Phone: +972-3-645-5421
|
|
Fax: +972-3-760-7844"
|
|
DESCRIPTION
|
|
"Configuration Change MIB."
|
|
::= { agnt 75 }
|
|
|
|
|
|
-- NE (Network Element) Configuration Change (Sync between NMS and Device)
|
|
--
|
|
|
|
-- The ConfigChange Notifications exist under the systemsEvents Node (RadGen.txt)
|
|
configChange OBJECT IDENTIFIER ::= { agnConfigChange 1 }
|
|
-- Additional nodes in the future can be added as { agnConfigChange 2, 3, 4 etc. }
|
|
|
|
--
|
|
-- Configuration Change Table --
|
|
--
|
|
configurationChangeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ConfigurationChangeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table includes all Configuration Tables OIDs that are supported by the device.
|
|
When a configuration change is performed on a table, the configuration change ID shall be incremented
|
|
and saved for this Table.
|
|
Note that the configuration change ID is a global parameter and will be incremented whenever a change
|
|
is made on any configuration table in the device.
|
|
"
|
|
::= { configChange 1 }
|
|
|
|
configurationChangeEntry OBJECT-TYPE
|
|
SYNTAX ConfigurationChangeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entries for configurationChangeTable.
|
|
"
|
|
INDEX { configurationChangeFamilyOid }
|
|
::= { configurationChangeTable 1 }
|
|
|
|
ConfigurationChangeEntry ::= SEQUENCE {
|
|
configurationChangeFamilyOid OBJECT IDENTIFIER,
|
|
configurationChangeLastChangeId Unsigned32,
|
|
configurationChangeOIDType INTEGER
|
|
}
|
|
|
|
configurationChangeFamilyOid OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Object Identifier of the current configuration table's family.
|
|
This is the OID of the table that was configured without its row indices.
|
|
For scalars, the object identifier shall be the OID of the family/tree
|
|
that contains the changed scalar.
|
|
"
|
|
::= { configurationChangeEntry 1 }
|
|
|
|
configurationChangeLastChangeId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration Change Id of the current configuration table.
|
|
Each time a change is performed on the table (or scalars), the device shall increment
|
|
its configurationChangeId and save it in this MIB object for the changed table.
|
|
"
|
|
::= { configurationChangeEntry 2 }
|
|
|
|
configurationChangeOIDType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tableOID (2),
|
|
scalarOID (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object indicates whether the familyOID that was sent is an OID of a table or of a scalar.
|
|
"
|
|
::= { configurationChangeEntry 3 }
|
|
|
|
|
|
|
|
configurationChangeId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of configuration change in the device.
|
|
"
|
|
::= { configChange 2 }
|
|
|
|
-- Reserved ::= { configChange 3 }
|
|
|
|
configurationChangeTrapsEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object indicates whether a configurationChange Trap will be sent.
|
|
off (2) - configurationChangeTrap will not be sent.
|
|
on (3) - configurationChangeTrap will be sent.
|
|
"
|
|
::= { configChange 4 }
|
|
|
|
configurationChangeEnd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
start (1),
|
|
end (2),
|
|
startAndEnd (3),
|
|
continue (4)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object shall be attached as a varbind to the configurationChange Trap.
|
|
It indicates whether the current configuration change trap has ended or whether it will be
|
|
continued in the next trap.
|
|
start (1) - the current configuration change trap is 1st in a sequence of configuration change traps.
|
|
end (2) - the current configuration change is the last in sequence of configuration change traps.
|
|
startAndEnd (3) - the current configuration change is a single trap.
|
|
continue (4) - the current configuration change is within a trap sequence, not 1st and not last.
|
|
"
|
|
::= { configChange 5 }
|
|
|
|
|
|
configChangeNotificationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ConfigChangeNotificationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table is used for marking the added, changed and removed instances.
|
|
In addition, it points to removed/added rows.
|
|
This table is used for notifications only.
|
|
"
|
|
::= { configChange 6 }
|
|
|
|
configChangeNotificationEntry OBJECT-TYPE
|
|
SYNTAX ConfigChangeNotificationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the configChangeNotificationTable.
|
|
Each entry contains the OID that is used for the changed/removed/added MIB object/row.
|
|
"
|
|
INDEX { configChangeNotificationFamilyOid }
|
|
::= { configChangeNotificationTable 1 }
|
|
|
|
ConfigChangeNotificationEntry ::= SEQUENCE {
|
|
configChangeNotificationFamilyOid OBJECT IDENTIFIER,
|
|
configChangeNotificationAdd OBJECT IDENTIFIER,
|
|
configChangeNotificationChange OBJECT IDENTIFIER,
|
|
configChangeNotificationRemove OBJECT IDENTIFIER
|
|
}
|
|
|
|
configChangeNotificationFamilyOid OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Family OID of the entry (row) that was removed or added to a configuration table.
|
|
The Family OID consists of the configured table OID without the row indices segment.
|
|
For a changed MIB object, the index will have a value of 0.0 ."
|
|
::= { configChangeNotificationEntry 1 }
|
|
|
|
configChangeNotificationAdd OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "This MIB object shall be attached to the configurationChange notification
|
|
when a row is added to a table.
|
|
The value of this MIB object will be 0.0 .
|
|
The index (configChangeNotificationFamilyOid) will be 0.0 too.
|
|
This MIB object marks the beginning of the Add section in the notification.
|
|
It shows that a cluster of additions is now beginning.
|
|
After this variable, all the added variables with their values will follow.
|
|
"
|
|
::= { configChangeNotificationEntry 2 }
|
|
|
|
configChangeNotificationChange OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "This MIB object shall be attached to the configurationChange notification
|
|
when a MIB object has been changed.
|
|
The value of this MIB object will be 0.0 .
|
|
The index (configChangeNotificationFamilyOid) will be 0.0 too.
|
|
This MIB object marks the beginning of the Change section in the notification.
|
|
It shows that a cluster of changes is now beginning.
|
|
After this variable, all the changed variables with their new values will follow.
|
|
"
|
|
::= { configChangeNotificationEntry 3 }
|
|
|
|
configChangeNotificationRemove OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "This MIB object shall be attached to the configurationChange notification
|
|
when a row is removed from a table. Its value is the indices of the removed row.
|
|
configChangeNotificationFamilyOid with the configChangeNotificationRemove OIDs
|
|
point to the removed row.
|
|
"
|
|
::= { configChangeNotificationEntry 4 }
|
|
|
|
|
|
configChangeTransactionKey OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object defines the unique information specifically associated with a configuration
|
|
SET PDU. The agent will return the transaction key as a varbind in the
|
|
systemConfigurationChange trap."
|
|
::= { configChange 7 }
|
|
|
|
|
|
--------------------------------------------
|
|
-- Configuration Change Common Trap Definitions
|
|
--------------------------------------------
|
|
|
|
systemConfigurationChange NOTIFICATION-TYPE
|
|
OBJECTS { configurationChangeId, configChangeTransactionKey }
|
|
-- Additional attached variables: configChangeNotificationAdd,
|
|
-- List of Added rows fields with their values,
|
|
-- configChangeNotificationChange,
|
|
-- List of MIB objects that were changed with their new values,
|
|
-- For each removed row: configChangeNotificationRemove,
|
|
-- configurationChangeEnd, -> for last trap only
|
|
-- trapSeqId
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Trap shall be sent upon any configuration change in the device. "
|
|
::= { systemsEvents 79}
|
|
|
|
systemConfigChangeEnableTraps NOTIFICATION-TYPE
|
|
OBJECTS { sysName, configurationChangeId, configurationChangeTrapsEnable }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Trap shall be sent when the user enables/disables the configurationChange Trap.
|
|
configurationChange traps will not be sent."
|
|
::= { systemsEvents 80}
|
|
|
|