Observium_CE/mibs/rad/RAD-ConfigChange-MIB

284 lines
10 KiB
Plaintext

RAD-ConfigChange-MIB DEFINITIONS ::= BEGIN
-- It is RAD's intent to encourage the widespread use of
-- this Specification in connection with the management of
-- RAD products. RAD grants vendors, end-users,
-- and other interested parties a non-exclusive license to
-- use this Specification in connection with the management
-- of RAD products.
-- This Specification is supplied "as is," and RAD makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.
IMPORTS
sysName FROM SNMPv2-MIB
Unsigned32, OBJECT-TYPE, MODULE-IDENTITY,
NOTIFICATION-TYPE FROM SNMPv2-SMI
systemsEvents FROM RAD-GEN-MIB
agnt FROM RAD-SMI-MIB;
agnConfigChange MODULE-IDENTITY
LAST-UPDATED "201502191800Z" -- February 19, 2015
ORGANIZATION "RAD Data Communications Ltd."
CONTACT-INFO
"System Department
Email: mibs@rad.com
Postal: RAD Data Communications Ltd.
24 Raoul Wallenberg St.
Tel-Aviv 6971920
Israel
Phone: +972-3-645-5421
Fax: +972-3-760-7844"
DESCRIPTION
"Configuration Change MIB."
::= { agnt 75 }
-- NE (Network Element) Configuration Change (Sync between NMS and Device)
--
-- The ConfigChange Notifications exist under the systemsEvents Node (RadGen.txt)
configChange OBJECT IDENTIFIER ::= { agnConfigChange 1 }
-- Additional nodes in the future can be added as { agnConfigChange 2, 3, 4 etc. }
--
-- Configuration Change Table --
--
configurationChangeTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConfigurationChangeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes all Configuration Tables OIDs that are supported by the device.
When a configuration change is performed on a table, the configuration change ID shall be incremented
and saved for this Table.
Note that the configuration change ID is a global parameter and will be incremented whenever a change
is made on any configuration table in the device.
"
::= { configChange 1 }
configurationChangeEntry OBJECT-TYPE
SYNTAX ConfigurationChangeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries for configurationChangeTable.
"
INDEX { configurationChangeFamilyOid }
::= { configurationChangeTable 1 }
ConfigurationChangeEntry ::= SEQUENCE {
configurationChangeFamilyOid OBJECT IDENTIFIER,
configurationChangeLastChangeId Unsigned32,
configurationChangeOIDType INTEGER
}
configurationChangeFamilyOid OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Object Identifier of the current configuration table's family.
This is the OID of the table that was configured without its row indices.
For scalars, the object identifier shall be the OID of the family/tree
that contains the changed scalar.
"
::= { configurationChangeEntry 1 }
configurationChangeLastChangeId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Configuration Change Id of the current configuration table.
Each time a change is performed on the table (or scalars), the device shall increment
its configurationChangeId and save it in this MIB object for the changed table.
"
::= { configurationChangeEntry 2 }
configurationChangeOIDType OBJECT-TYPE
SYNTAX INTEGER {
tableOID (2),
scalarOID (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This MIB object indicates whether the familyOID that was sent is an OID of a table or of a scalar.
"
::= { configurationChangeEntry 3 }
configurationChangeId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of configuration change in the device.
"
::= { configChange 2 }
-- Reserved ::= { configChange 3 }
configurationChangeTrapsEnable OBJECT-TYPE
SYNTAX INTEGER {
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB object indicates whether a configurationChange Trap will be sent.
off (2) - configurationChangeTrap will not be sent.
on (3) - configurationChangeTrap will be sent.
"
::= { configChange 4 }
configurationChangeEnd OBJECT-TYPE
SYNTAX INTEGER {
start (1),
end (2),
startAndEnd (3),
continue (4)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This MIB object shall be attached as a varbind to the configurationChange Trap.
It indicates whether the current configuration change trap has ended or whether it will be
continued in the next trap.
start (1) - the current configuration change trap is 1st in a sequence of configuration change traps.
end (2) - the current configuration change is the last in sequence of configuration change traps.
startAndEnd (3) - the current configuration change is a single trap.
continue (4) - the current configuration change is within a trap sequence, not 1st and not last.
"
::= { configChange 5 }
configChangeNotificationTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConfigChangeNotificationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table is used for marking the added, changed and removed instances.
In addition, it points to removed/added rows.
This table is used for notifications only.
"
::= { configChange 6 }
configChangeNotificationEntry OBJECT-TYPE
SYNTAX ConfigChangeNotificationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the configChangeNotificationTable.
Each entry contains the OID that is used for the changed/removed/added MIB object/row.
"
INDEX { configChangeNotificationFamilyOid }
::= { configChangeNotificationTable 1 }
ConfigChangeNotificationEntry ::= SEQUENCE {
configChangeNotificationFamilyOid OBJECT IDENTIFIER,
configChangeNotificationAdd OBJECT IDENTIFIER,
configChangeNotificationChange OBJECT IDENTIFIER,
configChangeNotificationRemove OBJECT IDENTIFIER
}
configChangeNotificationFamilyOid OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Family OID of the entry (row) that was removed or added to a configuration table.
The Family OID consists of the configured table OID without the row indices segment.
For a changed MIB object, the index will have a value of 0.0 ."
::= { configChangeNotificationEntry 1 }
configChangeNotificationAdd OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "This MIB object shall be attached to the configurationChange notification
when a row is added to a table.
The value of this MIB object will be 0.0 .
The index (configChangeNotificationFamilyOid) will be 0.0 too.
This MIB object marks the beginning of the Add section in the notification.
It shows that a cluster of additions is now beginning.
After this variable, all the added variables with their values will follow.
"
::= { configChangeNotificationEntry 2 }
configChangeNotificationChange OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "This MIB object shall be attached to the configurationChange notification
when a MIB object has been changed.
The value of this MIB object will be 0.0 .
The index (configChangeNotificationFamilyOid) will be 0.0 too.
This MIB object marks the beginning of the Change section in the notification.
It shows that a cluster of changes is now beginning.
After this variable, all the changed variables with their new values will follow.
"
::= { configChangeNotificationEntry 3 }
configChangeNotificationRemove OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "This MIB object shall be attached to the configurationChange notification
when a row is removed from a table. Its value is the indices of the removed row.
configChangeNotificationFamilyOid with the configChangeNotificationRemove OIDs
point to the removed row.
"
::= { configChangeNotificationEntry 4 }
configChangeTransactionKey OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB object defines the unique information specifically associated with a configuration
SET PDU. The agent will return the transaction key as a varbind in the
systemConfigurationChange trap."
::= { configChange 7 }
--------------------------------------------
-- Configuration Change Common Trap Definitions
--------------------------------------------
systemConfigurationChange NOTIFICATION-TYPE
OBJECTS { configurationChangeId, configChangeTransactionKey }
-- Additional attached variables: configChangeNotificationAdd,
-- List of Added rows fields with their values,
-- configChangeNotificationChange,
-- List of MIB objects that were changed with their new values,
-- For each removed row: configChangeNotificationRemove,
-- configurationChangeEnd, -> for last trap only
-- trapSeqId
STATUS current
DESCRIPTION
"This Trap shall be sent upon any configuration change in the device. "
::= { systemsEvents 79}
systemConfigChangeEnableTraps NOTIFICATION-TYPE
OBJECTS { sysName, configurationChangeId, configurationChangeTrapsEnable }
STATUS current
DESCRIPTION
"This Trap shall be sent when the user enables/disables the configurationChange Trap.
configurationChange traps will not be sent."
::= { systemsEvents 80}
-- Reserved ::= { systemsEvents 81}
END