APS-R-MIB DEFINITIONS ::= BEGIN
IMPORTS
InterfaceIndex FROM IF-MIB
RowStatus,
TEXTUAL-CONVENTION FROM SNMPv2-TC
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
MODULE-COMPLIANCE,
OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF
radExperimental FROM RAD-SMI-MIB
Integer32 , Counter32,
TimeTicks, OBJECT-TYPE,
MODULE-IDENTITY,
NOTIFICATION-TYPE FROM SNMPv2-SMI;
apsMIBr MODULE-IDENTITY
LAST-UPDATED "201401201811Z" -- January 20, 2014
ORGANIZATION "RAD Data Communications Ltd."
CONTACT-INFO
"System Department
Email: mibs@rad.com
Postal: RAD Data Communications Ltd.
24 Raoul Wallenberg St.
Tel-Aviv 6971920
Israel
Phone: +972-3-645-5421
Fax: +972-3-760-7844"
DESCRIPTION
"This is a draft adopted under RAD MIB before RFC3498 was released."
::= { radExperimental 2 }
-- radExperimental OBJECT IDENTIFIER ::= {iso (1) org (3) dod (6) internet (1) private (4) enterprises (1) rad (164) 20}
apsMIBObjectsR OBJECT IDENTIFIER
::= { apsMIBr 1 }
apsMIBNotificationsR OBJECT IDENTIFIER
::= { apsMIBr 2 }
apsMIBConformanceR OBJECT IDENTIFIER
::= { apsMIBr 3 }
ApsK1K2 ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This Textual Convention describes an object that stores
a SONET K1 and K2 byte APS protocol field.
K1 is located in the first octet, K2 is located in
the second octet.
Bits 1-4 of the K1 byte indicate a request.
1111 Lockout of Protection
1110 Forced Switch
1101 SF - High Priority
1100 SF - Low Priority
1011 SD - High Priority
1010 SD - Low Priority
1001 not used
1000 Manual Switch
0111 not used
0110 Wait-to-Restore
0101 not used
0100 Exercise
0011 not used
0010 Reverse Request
0001 Do Not Revert
0000 No Request
Bits 5-8 of the K1 byte indicate the channel associated with the
request defined in bits 1-4.
0000 is the Null channel
1-14 are working channels.
15 is the extra traffic channel
Bits 1-4 of the K2 byte indicate a channel. The channel is
defined with the same syntax as K1 Bits 5-8.
Bit 5 of the K2 byte indicates the
architecture.
0 if the architecture is 1+1
1 if the architecture is 1:n
Bits 6-8 of the K2 byte indicates the
mode.
000 - 011 are reserved for future use
100 indicates the mode is unidirectional
101 indicates the mode is bidirectional
110 RDI-L
111 AIS-L
"
REFERENCE
"Bellcore (Telcordia Technologies) GR-253-CORE, Issue 2,
Revision 2 (January 1999), 5.3.5."
SYNTAX OCTET STRING (SIZE (2))
ApsSwitchCommand ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An APS switch command allows a user to perform protection
switch actions.
The Switch command values are:
clear(1)
Clears all of the switch commands listed below for the specified
channel.
lockoutOfProtection(2)
Prevents any of the working channels from switching to the protection
line.
forcedSwitchWorkToProtect(3)
Switches the specified working channel to the protection line.
forcedSwitchProtectToWork(4)
Switches the working channel back from the protection line to
the working line.
manualSwitchWorkToProtect(5)
Switches the specified working channel to the protection line.
manualSwitchProtectToWork(6)
Switches the working channel back from the protection line to
the working line.
exercise(7)
Exercises the protocol for a protection switch of the specified
channel by issuing an Exercise request for that channel and
checking the response on the APS channel.
"
SYNTAX INTEGER {
clear(1),
lockoutOfProtection(2),
forcedSwitchWorkToProtect(3),
forcedSwitchProtectToWork(4),
manualSwitchWorkToProtect(5),
manualSwitchProtectToWork(6),
exercise(7)
}
ApsControlCommand ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An APS control command applies only to LTE that support the
1:n architecture and performs the following actions.
The Control command values are:
lockoutWorkingChannel(1)
Prevents the specified working channel from switching to the protection
line.
clearLockoutWorkingChannel(2)
Clears the lockout a working channel command for the channel specified.
"
SYNTAX INTEGER {
lockoutWorkingChannel(1),
clearLockoutWorkingChannel(2)
}
--
-- APS Configuration Table
--
-- This table supports the addition, configuration and deletion of APS
-- groups.
--
apsConfigR OBJECT IDENTIFIER ::= { apsMIBObjectsR 1 }
apsConfigGroupsR OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of APS groups."
::= { apsConfigR 1 }
apsConfigTableR OBJECT-TYPE
SYNTAX SEQUENCE OF ApsConfigEntryR
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists the APS groups that have been configured
on the system."
::= { apsConfigR 2 }
apsConfigEntryR OBJECT-TYPE
SYNTAX ApsConfigEntryR
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the apsConfigTable."
INDEX { IMPLIED apsConfigNameR }
::= { apsConfigTableR 1 }
ApsConfigEntryR ::=
SEQUENCE {
apsConfigNameR SnmpAdminString,
apsConfigRowStatusR RowStatus,
apsConfigModeR BITS,
apsConfigSdBerThresholdR Integer32,
apsConfigSfBerThresholdR Integer32,
apsConfigWaitToRestoreR Integer32,
apsConfigCreationTimeR TimeTicks,
apsConfigOperDelayR Integer32
}
-- apsConfigId OBJECT-TYPE
-- SYNTAX InterfaceIndex
-- MAX-ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "The ifIndex for the SONET line that is the designated
-- Protection line. The proptection's ifIndex provides a
-- unique id for the group which it protects."
-- ::= { apsConfigEntry 1 }
apsConfigNameR OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (1..32))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A textual name for the APS group."
::= { apsConfigEntryR 1 }
apsConfigRowStatusR OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this APS group entry.
An entry may not exist in the active state unless all
objects in the entry have an appropriate value. Also,
all associated apsChanConfigEntry rows must represent
a set of consecutive channel numbers beginning with
zero.
If this object is set to destroy, all associated
apsChanConfigEntry, apsCommandEntry and apsChanStatusEntry
rows will be deleted. Also, The fields apsMapGroupName
and apsMapChanNumber in apsMapEntry rows corresponding
to the deleted channels will be set to a string of size 0
and -1 respectively.
This object may be set to notInService. When set to
notInService changes may be made to apsConfigMode,
apsConfigSdBerThreshold, apsCOnfigSfBerThreshold,
and apsConfigWaitToRestore. Also, rows may be
added and deleted from apsChanConfigTable.
"
::= { apsConfigEntryR 2 }
apsConfigModeR OBJECT-TYPE
SYNTAX BITS {
onePlusOne(0),
oneToN(1),
revertive(2),
bidirectional(3),
extraTrafficAllowed(4),
onePlusOneOptimized(5),
pathProtection(6),
yCable(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The architecture and mode of the APS group.
The values mean:
onePlusOne
The 1+1 architecture permanently bridges the working
line to the protection line.
oneToN
The 1:n architecture allows one protection channel to
protect up to n working channels. When a fault is detected
on one of the n working channels that channel is bridged
over the protection channel.
Note: onePlusOne and oneToN are mutually exclusive.
revertive
When the condition that caused a switch to the protection
line has been cleared the signal is switched back to the
working line. If this bit is clear it indicates a
non-revertive system which remains on the protection line
until another switch request is received.
bidirectional
The bi-directional mode provides protection in both
directions.
If this bit is clear it indicates unidirectional mode which
provides protection in one direction. The default for 1:n is
bidirectional. The default for 1+1 is unidirectional.
extraTrafficAllowed
Extra traffic may be carried on the protection channel in
a 1:n architecture if this flag is set. It may be necessary
to disable this in order to interwork with other SONET
network elements that don't support extra traffic.
onePlusOneOptimized
If this bit is set it indicates that the protocol is:
G.783 Annex B - 1+1 bidirectional switching optimized for a
network using predominantly 1+1 bidirectional switching.
When this bit is set set all other bits should be cleared.
Multiplex section protection (MSP)1+1 optimized protocol
pathProtection
The path protection provides a protection in the SONET path
layer.
yCable
Y Cable connects each port to two ports on the other device,
transmissiion from both interfaces of the Y cable is forbidden
when one of the interfaces has LOS and the other one doesn't
a switch should be carried out.
This object may not be modified if the associated
apsConfigRowStatus object is equal to active(1)."
-- DEFVAL { '1'H }
::= { apsConfigEntryR 3 }
apsConfigSdBerThresholdR OBJECT-TYPE
SYNTAX Integer32 (5..9)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Signal Degrade Bit Error Rate.
The negated value of this number is used as the exponent of
10 for computing the threshold value for the Bit Error Rate
(BER). For example, a value of 5 indicates a BER threshold of
10^-5.
This object may not be modified if the associated
apsConfigRowStatus object is equal to active(1)."
DEFVAL { 5 }
::= { apsConfigEntryR 4 }
apsConfigSfBerThresholdR OBJECT-TYPE
SYNTAX Integer32 (3..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Signal Failure Bit Error Rate.
The negated value of this number is used as the exponent of
10 for computing the threshold value for the Bit Error Rate
(BER). For example, a value of 5 indicates a BER threshold of
10^-5.
This object may not be modified if the associated
apsConfigRowStatus object is equal to active(1)."
DEFVAL { 3 }
::= { apsConfigEntryR 5 }
apsConfigWaitToRestoreR OBJECT-TYPE
SYNTAX Integer32 (0..720)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Wait To Restore period in seconds.
This field only applies if revertive switching is enabled,
otherwise this value is ignored. After clearing of a
condition that necessitated an automatic switch, the
wait to restore period must elapse before reverting.
This is intended to avoid rapid switch oscillations.
This object may not be modified if the associated
apsConfigRowStatus object is equal to active(1)."
DEFVAL { 600 }
::= { apsConfigEntryR 6 }
apsConfigCreationTimeR OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time the associated
apsConfigRowStatus instance was set to active."
::= { apsConfigEntryR 7 }
apsConfigOperDelayR OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Wait To Operate upon event in hundreds of msec.
This field only applies if revertive switching is enabled,
otherwise this value is ignored. The Delay period must
elapse before starting operation.
This is intended to avoid rapid switch oscillations.
This object may not be modified if the associated
apsConfigRowStatus object is equal to active(1)."
DEFVAL { 10 }
::= { apsConfigEntryR 8 }
--
-- APS Status Table
--
-- This table provides APS group statistics.
--
apsStatusTableR OBJECT-TYPE
SYNTAX SEQUENCE OF ApsStatusEntryR
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides status information about APS groups that have
been configured on the system."
::= { apsMIBObjectsR 2 }
apsStatusEntryR OBJECT-TYPE
SYNTAX ApsStatusEntryR
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the apsStatusTable."
INDEX { IMPLIED apsConfigNameR }
::= { apsStatusTableR 1 }
ApsStatusEntryR ::= SEQUENCE {
apsStatusK1K2RcvR ApsK1K2,
apsStatusK1K2TransR ApsK1K2,
apsStatusCurrentR BITS,
apsStatusModeMismatchesR Counter32,
apsStatusChannelMismatchesR Counter32,
apsStatusPSBFsR Counter32,
apsStatusFEPLFsR Counter32
}
apsStatusK1K2RcvR OBJECT-TYPE
SYNTAX ApsK1K2
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current value of the K1 and K2 bytes received on the
protection channel."
::= { apsStatusEntryR 1 }
apsStatusK1K2TransR OBJECT-TYPE
SYNTAX ApsK1K2
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current value of the K1 and K2 bytes transmitted on the
protection channel."
::= { apsStatusEntryR 2 }
apsStatusCurrentR OBJECT-TYPE
SYNTAX BITS {
modeMismatch(0),
channelMismatch(1),
psbf(2),
feplf(3),
extraTraffic(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of the APS group.
modeMismatch
Modes other than 1+1 unidirectional monitor protection line
K2 bit 5, which indicates the architecture and K2 bits
6-8, which indicate if the mode is unidirectional or
bidirectional. A conflict between the current local mode
and the received K2 mode information constitutes a
mode mismatch.
channelMismatch
This bit indicates a mismatch between the transmitted K1 channel
and the received K2 channel has been detected.
psbf
This bit indicates a Protection Switch Byte Failure (PSBF) is
in effect. This condition occurs when an invalid code or
persistently unacceptable codes in the K1 byte are received.
feplf
Modes other than 1+1 unidirectional monitor the K1 byte
for Far-End Protection-Line failures. A Far-End
Protection-Line defect is declared based on receiving
SF on the protection line.
extraTraffic
This bit indicates whether extra traffic is currently being
accepted on the protection line.
"
::= { apsStatusEntryR 3}
apsStatusModeMismatchesR OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of Mode Mismatch conditions."
::= { apsStatusEntryR 4}
apsStatusChannelMismatchesR OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of Channel Mismatch conditions."
::= { apsStatusEntryR 5}
apsStatusPSBFsR OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of Protection Switch Byte Failure conditions.
This condition occurs when an invalid code or persistently
unacceptable codes in the K1 byte are received."
::= { apsStatusEntryR 6}
apsStatusFEPLFsR OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of Far-End Protection-Line Failure conditions.
This condition is declared based on receiving SF on
the protection line in the K1 byte."
::= { apsStatusEntryR 7}
--
-- APS Map Group
--
-- Lists the SONET LTE interfaces that may be used to create APS groups.
--
apsMapR OBJECT IDENTIFIER ::= { apsMIBObjectsR 3 }
apsChanLTEsR OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of available SONET LTE interfaces that may be included
in APS groups."
::= { apsMapR 1 }
apsMapTableR OBJECT-TYPE
SYNTAX SEQUENCE OF ApsMapEntryR
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists the SONET LTE interfaces that may be included in
APS groups. This is a list of all interfaces on the system with
ifType sonet(39)."
::= { apsMapR 2 }
apsMapEntryR OBJECT-TYPE
SYNTAX ApsMapEntryR
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the apsMapTableR."
INDEX { apsMapIfIndexR }
::= { apsMapTableR 1 }
ApsMapEntryR ::= SEQUENCE {
apsMapIfIndexR InterfaceIndex,
-- apsMapConfigId InterfaceIndex,
apsMapGroupNameR SnmpAdminString,
apsMapChanNumberR Integer32
}
apsMapIfIndexR OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Interface Index assigned to a SONET LTE. This is an interface
with ifType sonet(39)."
::= { apsMapEntryR 1 }
-- apsMapConfigId OBJECT-TYPE
-- SYNTAX InterfaceIndex
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The ifIndex for the SONET line that is the designated
-- Protection line. The proptection's ifIndex provides a
-- unique id for the group which it protects."
-- ::= { apsMapEntry 2 }
apsMapGroupNameR OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (1..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual name for the APS group which this channel is
included in.
If the channel is not part of an APS group this value is set to
a string of size 0."
::= { apsMapEntryR 2 }
apsMapChanNumberR OBJECT-TYPE
SYNTAX Integer32 (-1..14)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This field is set to a unique channel number within an APS group.
The value 0 indicates the null channel. The values 1-14 define a
working channel.
If the SONET LTE is not part of an APS group this value is set to -1."
::= { apsMapEntryR 3 }
--
-- APS Channel Configuration Table
--
-- This table supports the addition, configuration and deletion of channels
-- in APS groups.
--
apsChanConfigTableR OBJECT-TYPE
SYNTAX SEQUENCE OF ApsChanConfigEntryR
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists the APS channels that have been configured
in APS groups."
::= { apsMIBObjectsR 4 }
apsChanConfigEntryR OBJECT-TYPE
SYNTAX ApsChanConfigEntryR
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the apsChanConfigTable."
INDEX {apsChanGroupNameR, apsChanNumberR}
::= { apsChanConfigTableR 1 }
ApsChanConfigEntryR ::= SEQUENCE {
apsChanGroupNameR SnmpAdminString,
-- apsChanConfigId InterfaceIndex,
apsChanNumberR Integer32,
apsChanRowStatusR RowStatus,
apsChanIfIndexR InterfaceIndex,
apsChanPriorityR INTEGER
}
-- apsChanConfigId OBJECT-TYPE
-- SYNTAX InterfaceIndex
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The ifIndex for the SONET line that is the designated
-- Protection line. The proptection's ifIndex provides a
-- unique id for the group which it protects."
-- ::= { apsChanConfigEntry 1 }
apsChanGroupNameR OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (1..32))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A textual name for the APS group which this channel is
included in."
::= { apsChanConfigEntryR 1 }
apsChanNumberR OBJECT-TYPE
SYNTAX Integer32 (0..14)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This field is set to a unique channel number within an APS group.
The value 0 indicates the null channel. The values 1-14 define a
working channel.
This field must be assigned a unique number within the group."
::= { apsChanConfigEntryR 2 }
apsChanRowStatusR OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this APS channel entry.
An entry may not exist in the active state unless all
objects in the entry have an appropriate value.
A row may not be created with an apsChanGroupName value
equal to an apsConfigId(apsConfigName) value if the associated
apsConfigRowStatus object is equal to active. However,
if the apsConfigRowStatus object is equal to notInService,
a row may be created. In other words, a channel may not
be added to an active group.
A row may be created with an apsChanGroupName value
that is not equal to any existing instance of apsConfigId(apsConfigName).
This action is the initial step in adding a SONET LTE to a
new APS group. An instance of apsConfigId(apsConfigName) equal to this
instance of apsChanGroupName will subsequently be created.
If this object is set to destroy, the associated instance
of apsMapGroupName will be set to a string of size 0 and
the apsMapChanNumber will be set to -1
The channel command and channel status entries will also be
deleted by this action.
apsChanNumber must be set to a unique channel number within
the APS group. The value 0 indicates the null channel.
The values 1-14 define a working channel. When an attempt is
made to set the corresponding apsConfigRowStatus field to
active the apsChanNumber values of all entries with equal
apsChanGroupName fields must represent a set of consecutive
integer values beginning with 0 and ending with n, where n is
greater than or equal to 1 and less than or equal to 14. Otherwise
the error inconsistentValue is returned to the apsConfigRowStatus
set attempt.
"
::= { apsChanConfigEntryR 3 }
apsChanIfIndexR OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Interface Index assigned to a SONET LTE. This is an
interface with ifType sonet(39). This must not be set
to the InterfaceIndex of a SONET LTE that is currently
configured in an APS group. This cannot be set if
the group specified by apsChanGroupName is currently active.
"
::= { apsChanConfigEntryR 4 }
apsChanPriorityR OBJECT-TYPE
SYNTAX INTEGER {low(1), high(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The priority of the channel.
This field deterimines whether high or low priority
SD and SF codes are used in K1 requests.
This field is only applicable if the channel is to be included in
a group using the 1:n architecture. It is not applicable if the
channel is to be included in a group using the 1+1 architecture,
and is ignored in that case.
"
DEFVAL { low }
::= { apsChanConfigEntryR 5 }
--
-- APS Command Table
--
-- This table provides the ability to initiate APS commands.
--
apsCommandTableR OBJECT-TYPE
SYNTAX SEQUENCE OF ApsCommandEntryR
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table allows commands to be sent to configured APS groups."
::= { apsMIBObjectsR 5 }
apsCommandEntryR OBJECT-TYPE
SYNTAX ApsCommandEntryR
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the apsCommandTable."
INDEX {apsChanGroupNameR, apsChanNumberR}
::= { apsCommandTableR 1 }
ApsCommandEntryR ::= SEQUENCE {
apsCommandSwitchR ApsSwitchCommand,
apsCommandControlR ApsControlCommand
}
apsCommandSwitchR OBJECT-TYPE
SYNTAX ApsSwitchCommand
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allows the initiation of an APS switch command on the
APS group and channel specified by the index values.
When read this object returns the last command written
or clear(1) if no command has been written to this
channel since initialization. The return of the last command
written does not imply that this command is currently in effect.
This request may have been preempted by a higer priority
local or remote request. In order to determine the
current state of the APS group it is necessary to read
the objects apsStatusK1K2Rcv and apsStatusK1K2Trans.
The value lockoutOfProtection(2) should only be applied
to the protection line channel since that switch command
prevents any of the working channels from switching to the protection
line. Following the same logic, forcedSwitchProtectToWork(4) and
manualSwitchProtectToWork(6) should only be applied to the protection
line channel.
forcedSwitchWorkToProtect(3) and manualSwitchWorkToProtect(5)
should only be applied to a working channel.
"
::= { apsCommandEntryR 1 }
apsCommandControlR OBJECT-TYPE
SYNTAX ApsControlCommand
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allows the initiation of an APS control command on the
APS group and channel specified by the index values.
When read this object returns the last command written
or clearLockoutWorkingChannel(2) if no command has been
written to this channel since initialization.
This command should not be applied to the protection
line however, for simplicity the value clearLockoutWorkingChannel(2)
can be returned if this object is queried with the protection line
channel.
"
::= { apsCommandEntryR 2 }
--
-- APS Channel Status Table
--
-- This table provides APS channel statistics.
--
apsChanStatusTableR OBJECT-TYPE
SYNTAX SEQUENCE OF ApsChanStatusEntryR
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains status information for all SONET LTE
interfaces that are included in APS groups."
::= { apsMIBObjectsR 6 }
apsChanStatusEntryR OBJECT-TYPE
SYNTAX ApsChanStatusEntryR
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the apsChanStatusTable."
INDEX {apsChanGroupNameR, apsChanNumberR}
::= { apsChanStatusTableR 1 }
ApsChanStatusEntryR ::= SEQUENCE {
apsChanStatusR BITS,
apsChanSignalDegradesR Counter32,
apsChanSignalFailuresR Counter32,
apsChanSwitchoversR Counter32,
apsChanLastSwitchoverR TimeTicks
}
apsChanStatusR OBJECT-TYPE
SYNTAX BITS {
lockedOut(0),
sd(1),
sf(2),
switched(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the current state of the port.
lockedOut
This bit, when applied to a working channel, indicates that
the channel is prevented from switching to the protection line.
When applied to the null channel, this bit indicates that no
working channel may switch to the protection line.
sd - A signal degrade condition is in effect.
sf - A signal failure condition is in effect.
switched
The switched bit is applied to a working channel if that
channel is currently switched to the protection line."
::= { apsChanStatusEntryR 1 }
apsChanSignalDegradesR OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of Signal Degrade conditions. This
condition occurs when the line Bit Error Rate
exceeds the currently configured threshold."
::= { apsChanStatusEntryR 2 }
apsChanSignalFailuresR OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of Signal Failure conditions that have been
detected on the incoming signal. This condition occurs
when a loss of signal, loss of frame, AIS-L or a Line
bit error rate exceeding 10^-3 is detected on an
incoming line."
::= { apsChanStatusEntryR 3 }
apsChanSwitchoversR OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times this channel has switched to the protection
line. When queried with index value apsChanNumber set to 0, which
is the protection line, this object will return 0. "
::= { apsChanStatusEntryR 4 }
apsChanLastSwitchoverR OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this channel last completed a switch
to the protection line. If this channel has never switched to the
protection line, or this channel is the protection line, the value
0 will be returned."
::= { apsChanStatusEntryR 5 }
--
-- APS TRAPS
--
apsNotificationsPrefixR OBJECT IDENTIFIER
::= { apsMIBNotificationsR 0 }
apsTrapSwitchoverR NOTIFICATION-TYPE
OBJECTS { apsChanSwitchoversR, apsChanStatusR }
STATUS current
DESCRIPTION
"An apsTrapSwitchover notification is sent when the
value of an instance of apsChanSwitchovers increments."
::= { apsNotificationsPrefixR 1 }
apsTrapModeMismatchR NOTIFICATION-TYPE
OBJECTS { apsStatusModeMismatchesR, apsStatusCurrentR }
STATUS current
DESCRIPTION
"An apsTrapModeMismatch notification is sent when the
value of an instance of apsStatusModeMismatches increments."
::= { apsNotificationsPrefixR 2 }
apsTrapChannelMismatchR NOTIFICATION-TYPE
OBJECTS { apsStatusChannelMismatchesR, apsStatusCurrentR }
STATUS current
DESCRIPTION
"An apsTrapChannelMismatch notification is sent when the
value of an instance of apsStatusChannelMismatches increments."
::= { apsNotificationsPrefixR 3 }
apsTrapPSBFr NOTIFICATION-TYPE
OBJECTS { apsStatusPSBFsR, apsStatusCurrentR }
STATUS current
DESCRIPTION
"An apsTrapPSBF notification is sent when the
value of an instance of apsStatusPSBFs increments."
::= { apsNotificationsPrefixR 4 }
apsTrapFEPLFr NOTIFICATION-TYPE
OBJECTS { apsStatusFEPLFsR, apsStatusCurrentR }
STATUS current
DESCRIPTION
"An apsTrapFEPLFs notification is sent when the
value of an instance of apsStatusFEPLFs increments."
::= { apsNotificationsPrefixR 5 }
-- conformance information
apsGroupsR OBJECT IDENTIFIER ::= { apsMIBConformanceR 1 }
apsCompliancesR OBJECT IDENTIFIER ::= { apsMIBConformanceR 2 }
apsComplianceR MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for linear APS groups."
MODULE
MANDATORY-GROUPS { apsConfigGeneralR, apsStatusGeneralR, apsChanGeneralR }
OBJECT apsConfigModeR
-- ACCESS read-write
DESCRIPTION
"Write access is not required."
OBJECT apsConfigSdBerThresholdR
-- ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT apsConfigSfBerThresholdR
-- ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT apsConfigWaitToRestoreR
-- ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT apsConfigRowStatusR
-- ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT apsChanIfIndexR
-- ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT apsChanPriorityR
-- ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT apsChanRowStatusR
-- ACCESS read-only
DESCRIPTION
"Write access is not required."
GROUP apsConfigOneToNr
DESCRIPTION
"Implementation of this group is optional for all
linear APS implementations. The information is
applicable to groups implementing the linear
APS 1:n architecture"
GROUP apsCommandOnePlusOneR
DESCRIPTION
"Implementation of this group is optional for all
linear APS implementations. The information is
applicable to groups implementing the linear
APS 1+1 architecture and supporting set operations."
GROUP apsCommandOneToNr
DESCRIPTION
"Implementation of this group is optional for all
linear APS implementations. The information is
applicable to groups implementing the linear
APS 1:n architecture and supporting set operations."
GROUP apsChanOneToNr
DESCRIPTION
"Implementation of this group is optional for all
linear APS implementations. The information is
applicable to groups implementing the linear
APS 1:n architecture."
GROUP apsTotalsGroupR
DESCRIPTION
"Implementation of this group is optional for all
linear APS implementations."
GROUP apsMapGroupR
DESCRIPTION
"Implementation of this group is optional for all
linear APS implementations."
::= { apsCompliancesR 1 }
-- units of conformance
apsConfigGeneralR OBJECT-GROUP
OBJECTS
{
apsConfigRowStatusR,
apsConfigModeR,
apsConfigSdBerThresholdR,
apsConfigSfBerThresholdR,
apsConfigOperDelayR,
apsConfigCreationTimeR
}
STATUS current
DESCRIPTION
"A collection of apsConfigTable objects providing configuration
information applicable to all linear APS groups."
::= { apsGroupsR 1 }
apsConfigOneToNr OBJECT-GROUP
OBJECTS
{
apsConfigWaitToRestoreR
}
STATUS current
DESCRIPTION
"The apsConfigTable object that provides information which is only
applicable to groups implementing the linear APS 1:n architecture."
::= { apsGroupsR 2 }
-- If set operations are not supported neither of the following two groups
-- are implemented. If sets are supported only one of these groups is
-- implemented for a linear APS group instance.
apsCommandOnePlusOneR OBJECT-GROUP
OBJECTS
{
apsCommandSwitchR
}
STATUS current
DESCRIPTION
"The apsCommandTable object which is applicable to groups
implementing the linear APS 1+1 architecture. Also, set operations
must be supported."
::= { apsGroupsR 3 }
apsCommandOneToNr OBJECT-GROUP
OBJECTS
{
apsCommandSwitchR,
apsCommandControlR
}
STATUS current
DESCRIPTION
"A collection of apsCommandTable objects which are applicable to
groups implementing the linear APS 1:n architecture. Also, set
operations must be supported."
::= { apsGroupsR 4 }
apsStatusGeneralR OBJECT-GROUP
OBJECTS
{
apsStatusK1K2RcvR,
apsStatusK1K2TransR,
apsStatusCurrentR,
apsStatusModeMismatchesR,
apsStatusChannelMismatchesR,
apsStatusPSBFsR,
apsStatusFEPLFsR
}
STATUS current
DESCRIPTION
"A collection of apsStatusTable objects providing status information
applicable to all linear APS groups."
::= { apsGroupsR 5 }
apsChanGeneralR OBJECT-GROUP
OBJECTS
{
apsChanIfIndexR,
apsChanRowStatusR,
apsChanStatusR,
apsChanSignalDegradesR,
apsChanSignalFailuresR,
apsChanSwitchoversR,
apsChanLastSwitchoverR
}
STATUS current
DESCRIPTION
"A collection of channel objects providing information applicable to
all linear APS channels."
::= { apsGroupsR 6 }
apsChanOneToNr OBJECT-GROUP
OBJECTS
{
apsChanPriorityR
}
STATUS current
DESCRIPTION
"The apsChanConfigTable object that provides information which is only
applicable to groups implementing the linear APS 1:n architecture."
::= { apsGroupsR 7 }
apsTotalsGroupR OBJECT-GROUP
OBJECTS
{
apsConfigGroupsR,
apsChanLTEsR
}
STATUS current
DESCRIPTION
"A collection of objects providing optional counts of configured APS groups
and SONET LTE interfaces."
::= { apsGroupsR 8 }
apsMapGroupR OBJECT-GROUP
OBJECTS
{
apsMapGroupNameR,
apsMapChanNumberR
}
STATUS current
DESCRIPTION
"A collection of apsMapTable objects providing a mapping
from sonet(39) InterfaceIndex to group name and channel
number for assigned APS channels and a list of unassigned
sonet(39) interfaces."
::= { apsGroupsR 9 }
apsTrapOptionalR NOTIFICATION-GROUP
NOTIFICATIONS {apsTrapSwitchoverR, apsTrapModeMismatchR,
apsTrapChannelMismatchR, apsTrapPSBFr,
apsTrapFEPLFr }
STATUS current
DESCRIPTION
"A collection of SONET linear APS notifications that may optionally be
implemented."
::= { apsGroupsR 10 }
END