Observium_CE/mibs/proxim/ORiNOCO-MIB

12877 lines
448 KiB
Plaintext

--=============================================================================
--
-- Proxim Corporation - WiFi Research and Development
-- 935 Stewart Drive
-- Sunnyvale, CA 94085
-- USA
--
--=============================================================================
--
-- ORiNOCO Management Information Base (MIB)
--
--=============================================================================
--
-- FILENAME: orinoco.mib
--
-- DESIGNER: Daniel R. Borges (DRB)
--
-- TITLE: ORiNOCO Management Information Base
--
-- USED IN: ORiNOCO Product Line for SNMP Management. This MIB is
-- intended for the following products:
-- Access Point Products
-- Broadband Gateway Products
-- Tsunami Multi-point Products
--
--=============================================================================
--
-- Document History Information
--
--=============================================================================
--
-- Version Date Authors Decription
--
--=============================================================================
-- v1.00 Aug 29 DRB, Lucent Intitial Document Creation
-- 2000
--=============================================================================
-- v1.10 Sept 01 DRB, Lucent Removal of unecessary objects.
-- 2000
--=============================================================================
-- v1.20 Sept 04 DRB, Lucent Correction on Ranges for IAPP
-- 2000 Parameters.
--=============================================================================
-- v1.30 Sept 07 DRB, Lucent Appropriate values set fro the IAPP
-- 2000 Parameters.
--=============================================================================
-- v1.40 Sept 08 NRP, Lucent Updated all objects.
-- 2000
--=============================================================================
-- v1.50 Sept 12 DRB, Lucent Added objects to enable/disable the
-- 2000 trap Groups and also added new traps.
-- Added Session Idle Timeout object to
-- PPP Group.
--=============================================================================
-- v1.60 Sept 26 DRB, Lucent Change name of group from web to HTTP.
-- 2000 Added RG-2000 to ORiNOCO product tree.
--=============================================================================
-- v1.70 Oct 30 DRB, Lucent Added trap and trap variable to inform
-- 2000 when a software task has suspended.
--=============================================================================
-- v1.80 Nov 15 DRB, Lucent Changed underscore characters to dashes
-- 2000 and removed conflict between two trap
-- variables:
-- oriConfigurationTrapsStatus
-- oriTrapVarTaskSuspended
--=============================================================================
-- v1.90 Feb 05 DRB, Lucent Sync up between ORiNOCO MIB and AS-2000
-- 2001 MIB objects. The following changes
-- were made:
-- 1. Changed the following indeces from
-- non-accessible to read-only:
-- - oriSNMPAccessTableIndex
-- - oriSNMPTrapHostTableIndex
-- - oriProtocolFilterTableIndex
-- - oriAccessControlTableIndex
-- - oriStaticMACAddressFilterTableIndex
-- - oriLinkIntTableIndex
-- - oriPPPMACtoIPTableIndex
-- - oriPPPIPPoolTableIndex
-- - oriDHCPServerIPPoolTableIndex
-- - oriProxyAgentAPTableIndex
-- - oriStormThresholdIfIndex
-- 2. Added the following objects:
-- - oriSystemInvMgmtBSPBootloaderVersion
-- - AS Client IPX Table
-- 3. Change to range value of
-- oriTFTPFileType, included all file
-- type available on the AS-2000
-- device. This should be reviewed
-- and decided if going to be supported
-- in other ORiNOCO devices.
-- 4. Added the following objects the
-- the Link Test Table:
-- - oriLinkTestInterface
-- - oriLinkTestRadioType
-- 5. Added Access Server IAPP station
-- table to IAPP group.
-- 6. Added Traps for RADIUS Auth and
-- Acct not configured.
-- 7. Changed range on
-- oriPPPSessionIdleTimeout object.
--=============================================================================
-- v2.00 Feb 13 DRB, Lucent Added the following objects to sync up
-- 2001 AS-2000 MIB:
-- - oriIfProfileCode
-- - oriSystemReboot
-- - oriSystemContactEmail
-- - oriIfMACAddress
-- Made Inventory Management a sub-group
-- of System Group.
-- Removed oriPPPNumIPPoolTableEntry from
-- PPP group - duplicate object.
--=============================================================================
-- v2.01 Feb 13 DRB, Lucent Added default value to appropriate
-- 2001 objects.
--=============================================================================
-- v2.02 Mar 05 DRB, Agere Following Changes have been made to the
-- 2001 ORiNOCO MIB:
-- 1. Created Interface group and placed
-- wireless and ethernet interfaces as
-- sub-group.
-- 2. Created two tables under the
-- wireless interface group for
-- properties and security objects.
-- 3. Create IP and IPX sub-group under
-- Network group.
-- 4. Moved DHCP Client Type into the
-- Network IP sub-group.
-- 5. Created Authentication and
-- Accounting sub-groups under the
-- RADIUS group.
-- 6. Created Hardware, Software,
-- Firmware, and BSP/BL sub-groups
-- under System Inventory Mgmt Group.
-- 7. Removed
-- oriIfInvMgmtRadioFirmwareDate for it
-- does not exist.
-- 8. Renamed oriWirelessIfDeliveryTraffi-
-- cIndicationMap to
-- oriWirelessIfDTIMPeriod and made
-- corrections to description.
-- 9. Created Miscellaneous Trap group.
--=============================================================================
-- v2.03 Mar 14 DRB, Agere Following Changes have been made to the
-- 2001 ORiNOCO MIB:
-- 1. Add delete as an integer value to
-- the following tables:
-- - oriProtocolFilterTable
-- - oriAccessControlTable
-- - oriStaticMACAddressFilterTable
-- 2. Added the following object required
-- for AP-2000 software:
-- - oriSystemContactPhoneNumber
-- - oriProtocolFilterProtocol-
-- Comment to Protocol Table.
-- - oriHTTPUserName
-- 3. Fixed range for Storm Threshold
-- Broadcast and Multicast Objects.
-- 4. Removed the
-- oriStormThresholdIfIndex from
-- Storm Threshold table. The IfIndex
-- from MIB-II interface table shall
-- be used.
-- 5. Moved Gateway IP Address, default
-- lease time, maximum lease time from
-- DHCP group to the DHCP IP Pool
-- Table.
--=============================================================================
-- v2.04 Mar 26 DRB, Agere Removed Proxy Agent Group.
-- 2001 Specified values for
-- oriSNMPAccessTableInterface.
-- Added SNMPSetupStatus in order to
-- enable/disable SNMP based Management.
-- Added oriIAPPSendAnnounceRequestOnStart
-- to the IAPP Group.
-- Added the following objects to the
-- Systems Group:
-- - oriSystemFlashUpdate
-- - oriSystemFlashBackupInterval
-- - oriSystemEmergencyResetToDefault
-- Added the following Groups:
-- - Proxy ARP (orinocoProxyARP)
-- - Spanning Tree (orinocoSpanningTree)
-- - PTP (orinocoPTP)
--=============================================================================
-- v2.05 Mar 30 DRB, Agere Added Import of ifIndex from RFC-1213
-- 2001 and correct object name ot ifIndex.
--=============================================================================
-- v2.06 Apr 03 DRB, Agere Removed the
-- 2001 oriSNMPTestReadWritepassword from the
-- MIB.
--=============================================================================
-- v2.07 Apr 10 DRB, Agere Renamed Inventory Management Objects
-- 2001 from ComputerID to ComponentID.
-- Defined Inventory Management Parameters
-- for BSP/BL, ORiNOCO MIB, and Wireless
-- Interface Cards.
--=============================================================================
-- v2.08 Apr 18 DRB, Agere Added Wireless Card primary firmware
-- 2001 inventory management objects, compID,
-- variant, major, and minor versions.
--=============================================================================
-- v2.09 Apr 26 DRB, Agere Changed PTP group name to WDS.
-- 2001 Modified the Spanning Tree Status
-- object modifying enable/disable
-- enumeration.
--=============================================================================
-- v2.10 May 09 DRB, Agere Added the following Traps:
-- 2001 oriTrapZeroSizeImage
-- oriTrapInvalidImage
-- oriTrapImageTooLarge
-- oriTrapBootPFailed
-- oriTrapDHCPFailed
-- oriTrapDuplicateIPAddressEncountered
-- oriTrapWLCVoltageDiscrepancy
-- oriTrapWLCIncompatibleVendor
-- oriTrapWLCFirmwareDonwloadFailure
-- oriTrapWLCIncompatibleFirmware
-- Added the following Trap Variables:
-- oriTrapVarUnauthorizedClientMACAddress
-- oriTrapVarWirelessCard
-- Added object in order to enable/disable
-- the image trap group.
--=============================================================================
-- v2.11 May 16 DRB, Agere Added necessary objects to support
-- 2001 AP-2000 features/modules:
-- oriWirelessIfLoadBalancing
-- oriWirelessIfMediumDensityDistribution
-- oriStaticMACAddressFilterComment
-- oriDHCPServerIPPoolTableDNSIPAddress
-- Added 802.1x group with one object to
-- enable/disable this feature.
-- Added the following traps:
-- oriTrapIncompatibleImage
--=============================================================================
-- v3.00 May 18 DRB, Agere Converted MIB Definition from SMIv1 to
-- 2001 SMIv2. Modified 802.1x group to
-- security group and added security
-- configuration object and encryption key
-- length table per wireless interface.
--=============================================================================
-- v3.01 May 21 DRB, Agere Added RG-1100 in the product branch as
-- 2001 orinocoproduct number 8. Updated
-- comments to the link integrity objects.
-- Corrected RADIUS shared secret from
-- read-only to read-write. Added index
-- to interface table. Created a generic
-- inventory management table for
-- components and component interfaces.
--=============================================================================
-- v3.02 May 23/24 DRB, Agere Added Protocol Packet Filter sub-group
-- 2001 under Filtering Group. Added interface
-- bit mask to Protocol Filtering table.
-- Added PPPoE Group. Removed Gateway IP
-- Address, Subnetmask, and DNS IP Address
-- from DHCP Server Table and made them
-- scalar objects. Added Secondary DNS IP
-- Address in DHCP group.
-- Added System mode to be supported by
-- RG-2. Added Configuration File group
-- for RG-2. Added HTTP file name
-- table, refresh delay, and HTTP mgmt per
-- interface in the HTTP group. Added
-- DNS Redirect Group. Added Event Log
-- to system group. Added an AOL group.
-- Changed EthernetIf Settings into a
-- table since RG-2 has two ethernet ifs.
-- Added network IP configuration table
-- since RG-2 has two ethernet interfaces.
--=============================================================================
-- v3.03 May 30 DRB, Agere Corrected oriPPPoEMACtoSessionTableISP-
-- 2001 Name object type to DisplayString.
--=============================================================================
-- v3.04 June 11 DRB, Agere Updated trap description with severity
-- 2001 level. Changed trap variables from
-- read-only to not-accessible.
--=============================================================================
-- v3.05 June 20 DRB, Agere Added two new sub-groups to the DHCP
-- 2001 group, namely server and client.
-- Added Create State to all tables.
-- Modified oriConfigFileName to read-only
-- Added index to the oriPPPoESessionTable
-- and oriPPPoEMACtoSessionTable.
-- Changed HTTP Status and SNMP Status
-- interface bit mask. Modified
-- description on multicast rate.
--=============================================================================
-- v3.06 June 21 DRB, Agere Removed IP Address Type object, since
-- 2001 object added to DHCP client group.
-- Added index to EventLog Table and
-- added create to HTTP table status
-- object. Changed data-type of WEP keys
-- to OCTET STRING. Added statement
-- to description of objects that ought to
-- be treated as write-only (masked):
-- - Encryption Keys (WEP)
-- - Passwords
-- - RADIUS Shared Secret
--=============================================================================
-- v3.07 Oct 15 DRB, Agere Added ADSL Interface Group as a
-- 2001 subgroup to ORiNOCO Interface.
--=============================================================================
-- v3.08 Oct 16, 17 DRB, Agere Changed data-type of WEP keys to
-- 2001 DisplayString. Added object to SNMP
-- group disable/enable the IP Access
-- Table. Added object for Protocol
-- Filter interface bit mask. Added the
-- port filter sub-group to filtering
-- group. Removed Primary and Secondary
-- DNS IP address objects from DHCP Server
-- group and added it to DNS group.
-- Changed DNSRedirect group to DNS group.
-- Changed OID of DHCP Client ID object to
-- 1 (instead of 2). Removed DHCP Client
-- address type since it is already in the
-- network group. Added NAT group. Added
-- system user name and password for HTTP
-- and telnet access. Removed default
-- values for network IP address, subnet
-- mask and gateway IP address objects
-- since it is product specific. Added
-- manual value to PPPoE WAN Connect mode
-- object. Added a PPPoE WAN connect mode
-- status object. Added a Ping Test
-- group. Added a mask for filtering the
-- severity of the event log table.
-- Changed the following object names:
-- oriProtocolFilterIfMask to
-- oriProtocolFilterInterfaceBitMask
-- oriProtocolFilterFlag to
-- oriProtocolFilterOperationType
-- Added Counter64 to data type import
-- list. Changed MAX-ACCESS of trap
-- variables from not-accessible to
-- read-only. Updated contact info for
-- MIB module identity. Removed Event Log
-- index from Event Log Table.
--=============================================================================
-- v3.09 Oct 22 DRB, Agere Removed the following traps:
-- 2001 oriTrapsADSLIfProfile0Status
-- oriTrapsADSLIfProfile1Status
-- Added a single trap control object for
-- ADSL interface related traps and added
-- and ADSL trap group.
--=============================================================================
-- v3.10 Oct 23 DRB, Agere Changed the ADSL Interface Profile
-- 2001 configuration to index 1 and 2.
--=============================================================================
-- v3.11 Oct 30 DRB, Agere Added ADSL Advanced Statistics Group
-- 2001 and respective objects.
--=============================================================================
-- v3.12 Oct 31 DRB, Agere Added the following objects to the
-- 2001 System group for Telnet and HTTP
-- interface access:
-- - oriSystemAccessUserName
-- - oriSystemAccessPassword
-- - oriSystemAccessLoginTimeout
-- - oriSystemAccessIdleTimeout
--=============================================================================
-- v3.13 Dec 03 DRB, Agere Added objects for the following
-- 2001 feature groups:
-- - HereUare
-- - SpectraLink VoIP
-- - Advanced Bridging Filter
-- Modified Proxy ARP group to IP/ARP
-- group and added required objects for
-- IP/ARP filtering.
-- Changed the following table object
-- names for consistency:
-- - oriAccessControlMACAddress ->
-- oriAccessControlTableMACAddress
-- - oriAccessControlComment ->
-- oriAccessControlTableComment
-- - oriAccessControlEntryStatus ->
-- oriAccessControlTableEntryStatus
-- - oriLinkIntTableStatus ->
-- oriLinkIntTableEntryStatus
-- - oriWDSSetupTableStatus ->
-- oriWDSSetupTableEntryStatus
-- Changed default value of
-- oriTelnetLoginTimeout to 30 seconds.
-- Changed description of
-- oriLinkIntPollInterval.
-- Added oriHTTPHelpInformationLink to
-- HTTP group.
-- Added oriTrapWLCFirmwareFailure trap.
-- Changed the values of the Wireless Card
-- Distance between APs object to support
-- UHD firmware enhancement.
-- Added oriWirelessIfAutoChannelSelect
-- object to Wireless If Properties table.
--=============================================================================
-- v3.14 Dec 18 DRB, Agere Added VLAN group and required objects.
-- 2001 Added Primary and Secondary DNS Server
-- IP Addresses to DHCP Server group.
-- Updated description of Link Integrity
-- Interval and default value definition.
-- Default value defined for Link Test
-- table timeout. Changed location of
-- MODULE-IDENTITY macro to comply with
-- SNMP v2c. Modififed IAPP
-- Retransmission default value to 4.
-- Modified the following object names for
-- consistency:
-- - oriNetworkIPXClientStatus ->
-- oriNetworkIPXClientTableEntryStatus
-- - oriRADIUSAuthServerStatus ->
-- oriRADIUSAuthServerTableEntryStatus
-- - oriRADIUSAcctServerStatus ->
-- oriRADIUSAcctServerTableEntryStatus
-- - oriWirelessIfEncryptionStatus ->
-- oriWirelessIfEncryptionTableEntryStatus
-- - oriStaticMACAddressFilterStatus ->
-- oriStaticMACAddressFilterTableEntryStatus
-- - oriBroadcastFilteringStatus ->
-- oriBroadcastFilteringTableEntryStatus
-- Added trap variable to specify the
-- client failed authentication type.
-- Modified enterprise OID to Agere
-- Systems assigned OID number 11898.
--=============================================================================
-- v3.15 Jan 08 DRB, Agere Updated description for
-- 2002 oriWirelessIfAllowedSupportedDataRates.
-- Modified the VLAN group to include
-- the following objects:
-- - Status
-- - Frame Types
-- - Table of VLAN IDs
-- Added the following groups, subgroups,
-- and objects for the OR-2000 Product.
-- - orinocoWORP
-- - orinocoWORPConfiguration
-- - orinocoWORPAuthentication
-- - orinocoDHCPRelay
-- Added 5 Traps for the OR-2000 Product.
-- Changed default value for Auto Channel
-- Select object. Modified status of
-- oriTelnetSessions to obsolete since no
-- longer used.
-- Modified the following object names for
-- consistency:
-- - oriProtocolFilterStatus ->
-- oriProtocolFilterTableEntryStatus
-- - oriWirelessIfAutoChannelSelect ->
-- oriWirelessIfAutoChannelSelectStatus
-- - oriWirelessIfEncryptionTableEntryStatus
-- oriWirelessIfEncryptionStatus
--=============================================================================
-- v3.16 Jan 28 DRB, Agere Added Textual Convention for VLAN Tag
-- 2002 ID Type. Added VLAN Mgmt Tag ID to
-- VLAN group. Changed the VLAN ID object
-- type to the defined textual convention.
-- Added the following groups, subgroups,
-- tables, and objects for mgmt of the
-- COR/ROR-2000 product, which could be
-- used by other products in the future:
-- - WORP Interface Config Subgroup and
-- table to orinocoIf group.
-- - WORP Statistics table to WORP
-- Interface subgroup.
-- - Feature based Licensing subgroup to
-- orinocoSys and added Feature table.
-- - Added group for monitoring station
-- statistics, orinocoStationStats
-- Modified the trap OIDs for conformance
-- with SMIv2 and SNMPv2c.
-- Removed the orinocoWORP group and
-- subgroups since this group was moved to
-- a subgroup for orinocoIf. Added RIP
-- subgroup to orinocoNETRIP.
--=============================================================================
-- v3.17 Feb 04 DRB, Agere Added Textual convention for Interface
-- 2002 Bitmask object.
-- Updated the description for the
-- following objects:
-- - oriSystemMode
-- - oriHTTPWebsiteNameTable
-- - oriHTTPWebSitenameTableIndex
-- - oriHTTPWebSiteFilename
-- - oriHTTPWebSiteLanguage
-- - oriHTTPWebSiteDescription
-- - oriHTTPWebSitenameTableStatus
-- - oriNetworkIPConfigTable
-- - oriSNMPAccessTableInterfaceBitmask
-- - oriSNMPInterfaceBitmask
-- - oriProtocolFilterInterfaceBitmask
-- - oriPortFilterTableEntryInterfaceBitmask
-- - oriTelnetInterfaceBitmask
-- - oriHTTPInterfaceBitmask
-- - oriSystemFeatureTable
-- - oriSystemFeatureTableEnry
-- - oriWORPIfConfigTableRegistrationTimeout
-- - oriWORPIfConfigTableRetries
-- Corrected the Notification Type OID.
-- Removed VLAN Frame Type Object and
-- reassigned OIDs to VLAN groups.
--=============================================================================
-- v3.18 Feb 05 DRB, Agere Added Tx Rate control to Wireless
-- 2002 interface table.
--=============================================================================
-- v3.19 Feb 21 DRB, Agere Corrected enumerated values for station
-- 2002 statistics table station type. Added
-- object for enabling/disabling
-- monitoring station statistics.
--=============================================================================
-- v3.20 Mar 25 DRB, Agere Merge between previous MIB version and
-- 2002 BG MIB.
-- Added TEXTUAL-CONVENTION,
-- MODULE-COMPLIANCE, and OBJECT-GROUP.
-- Modified INTEGER to Integer32 for the
-- VlanId textual convention.
-- Changed module identity and the
-- MIB tree structure.
-- Added oriSystemAccessMaxSessions to the
-- orinocoSys group.
-- Modified the enumerated values for the
-- oriTFTPFileType object.
-- Added the following object for
-- Bandwidth Throttling feature:
-- - oriWirelessIfBandwidthLimitIn
-- - oriWirelessIfBandwidthLimitOut
-- - oriEthernetIfBandwidthLimitIn
-- - oriEthernetIfBandwidthLimitOut
-- Added oriDHCPClientInterfaceBitmask to
-- DHCP Client subgroup.
-- Removed the following WORP Traps:
-- - oriWORPLinkDown
-- - oriWORPRegistrationIndication
-- - oriWORPSystemAuthenticationFailure
-- Added the following WORP Traps:
-- - oriWORPStationRegister
-- - oriWORPStationDeRegister
-- Added the following traps for System
-- Feature based License:
-- - oriTrapIncompatibleLicenseFile
-- - oriTrapFeatureNotSupported
-- - oriTrapZeroLicenseFiles
-- - oriTrapInvalidLicenseFile
-- - oriTrapUselessLicense
-- Added oriTrapVarInterface to the trap
-- variable group.
-- Changed type from Gauge32 to Integer32
-- and configured ranges for the following
-- objects:
-- - oriWORPIfStatTableAverageLocalSignal
-- - oriWORPIfStatTableAverageLocalNoise
-- - oriWORPIfStatTableAverageRemoteSignal
-- - oriWORPIfStatTableAverageRemoteNoise
-- - oriStationStatTableInSignal
-- - oriStationStatTableInNoise
-- - oriStationStatTableRemoteSignal
-- - oriStationStatTableRemoteNoise
-- Configured ranges for the following
-- objects:
-- - oriStationStatTableIndex
-- Updated description for the following
-- objects:
-- - oriStationStatTableAdminStatus
-- - oriStationStatTableOperStatus
-- - oriTrapAuthenticationFailure
-- - oriSystemFeatureTable
-- Removed the following objects from the
-- oriWORPIfStatTable:
-- - oriWORPIfStatTableRegistrationAborts
-- - oriWORPIfStatTableRequestIgnored
-- - oriWORPIfStatTableQueueLength
-- Added oriWORPIfConfigTableNetworkSecret
-- to oriWORPIfTable.
-- Removed orinocoNetRIP subgroup.
--=============================================================================
-- v3.21 Apr 01 DRB, Agere Updated the ADSL Interface Group with
-- 2002 requirements provided by BG team.
-- Changed object descriptions to be
-- generic and providing more information.
-- oriWirelessIfMACAddress status has been
-- changed to deprecated.
-- oriTelnetSessions status has been
-- changed to deprecated.
-- Added Trap for invalid VLAN ID
-- configuration.
-- Changed the data type and range for
-- oriWirelessIfEncryptionTxKey to
-- integer32 and size of 0-3.
-- Removed wep enumerated value from the
-- oriSecurityConfiguration object.
--=============================================================================
-- v3.22 Apr 24 DRB, Agere Added rekeying interval object to the
-- 2002 Security Group.
--=============================================================================
-- v3.23 June 25 DRB, Agere Added the following groups/subgroups/
-- 2002 objects to support AP-2000 2.1 release:
-- - Packet Forwarding
-- - IBSS Traffic Control
-- - Syslog
-- - DNS Client
-- - Syslog
-- Added RADIUS MAC Address format object
-- to RADIUS group. Added RADIUS Server
-- name and addressing type to both
-- Authentication and Accounting RADIUS
-- Server tables.
--=============================================================================
-- v3.24 June 28 DRB, Agere Changed RADIUS IP Address object status
-- 2002 to obsolete. Added two enumerated
-- values to PPPoE Session Connect Mode.
-- Added object to configure the interface
-- where the PPPoE client should try to
-- establish a PPPoE connection.
--=============================================================================
-- v3.25 July 2 DRB, Agere Added default value for RADIUS Server
-- 2002 Addressing Format. Added object to HTTP
-- group for enabling/disabling SSL.
--=============================================================================
-- v3.26 July 17 DRB, Agere Added certificate to TFTP File Type
-- 2002 Object. Added SSL password to HTTP
-- group. Added AlphaOne to the orinoco
-- product tree.
--=============================================================================
-- v3.27 July 23 DRB, Agere Added two additional values to RADIUS
-- 2002 MAC address delimiters. Changed DNS
-- Client status default value to disable.
-- Removed PPPoE Connection Interface obj.
-- Removed value from PPPoE connect mode.
-- Added Trap for when the DNS client can
-- not resolve a specified host name.
-- Added Turbo Mode obj in Wireless If
-- properties table. Updated description
-- on the data rates obj to address Turbo
-- mode speeds. Added value to key length
-- table for wide-key support. Added trap
-- for Radar Interference detected.
-- Corrected values in the encryption key
-- lenght table. Added object to enable
-- or disable the HTTP setup wizard.
--=============================================================================
-- v3.28 Aug 20 DRB, Agere Added orinocoSNTP group and respective
-- 2002 mgmt objs. Removed SSL and HereUare
-- objs since not supported.
--=============================================================================
-- v3.29 Sept 04 DRB, Proxim Added trap for SNTP failure. Changed
-- 2002 MIB header and Module Identity to
-- Proxim Corporation.
--=============================================================================
-- v3.30 Sept 18 DRB, Proxim Removed certificate from the TFTP File
-- 2002 type values. Removed AlwaysOnForRADIUS
-- from the PPPoE WAN connect mode values.
--=============================================================================
-- v3.31 Sept 24 DRB, Proxim Add AP-25000 (SmartAP) to
-- 2002 orinocoProducts tree. Added trap for
-- maximum number of subscribers reached.
--=============================================================================
-- v3.32.0 Sept 25 DRB, Proxim Changed the default value of RADIUS
-- 2002 Authorization Lifetime to 900.
--=============================================================================
-- v3.33.0 Oct 15 DRB, Proxim Corrected Index to the PPPoE Session
-- 2002 Table. Added textual convention for
-- status type objects. Removed default
-- value for frequency channel since it
-- depends on regulatory domain.
--=============================================================================
-- v3.34.0 Dec 05 DRB, Proxim Corrected the product name for AlphaOne
-- 2002 project to AP-600.
--=============================================================================
-- v3.35.0 Dec 17 DRB, Proxim Removed 152 bit option (for 11a cards)
-- 2002 from oriSecurityEncryptionKeyLength.
--=============================================================================
-- v3.36.1 March 25 DRB, Proxim Added objects to the wireless
-- 2003 interface properties table for 802.11g
-- feature support.
-- Removed the following groups/objects:
-- - oriSystemAdminState
-- - oriSystemAdminStateTimer
-- - orinocoADSLIf
-- - orinocoNetIPX
-- - orinocoECP
-- - orinocoPPP
-- - orinocoPing
-- - oriIAPPTerminatePPPSessionPDUsSent
-- - oriIAPPTerminatePPPSessionPDUsReceived
-- - oriIAPPTerminatePPPSessionACKsSent
-- - oriIAPPTerminatePPPSessionACKsReceived
-- - oriTrapIPAddrAssignmentNotConfigured
-- - oriTrapWINSIPNotConfigured
-- - oriTrapChangeInAdminState
-- - oriADSLIfTraps
--=============================================================================
-- v3.36.2 April 04 DRB, Proxim Udpate description Allowed TxRates and
-- 2003 TxRate object to reflect 802.11g data
-- rates. Added object to display the
-- supported wireless operational modes.
-- Corrected UTC time format in MIB
-- module identity.
--=============================================================================
-- v3.36.3 April 04 DRB, Proxim Added 802.11a only mode to operational
-- 2003 modes and corrected enumerated values.
--=============================================================================
-- v3.36.4 April 17 DRB, Proxim Changed multicast rate values and added
-- 2003 new object for supported multicast
-- rates. Added wireless operational
-- mode value. Changed syntax of
-- preamble type to DisplayString.
--=============================================================================
-- v3.36.5 April 21 DRB, Proxim Corrected typo with wireless
-- 2003 operational mode object.
--=============================================================================
-- v3.36.6 May 1 DRB, Proxim Deprecated deny-non encrypted data obj.
-- 2003 Added range for DHCP server lease
-- times. Updated description for
-- encryption options and regulatory
-- domain list objects.
--=============================================================================
-- v3.36.7 May 1 DRB, Proxim Changed range for RADIUS (Auth and
-- 2003 Acct) server maximum retransmission.
--=============================================================================
-- v3.37.0 May 16 DRB, Proxim Modified Textual convention for Vlanid.
-- 2003 Modified range for DTIM Period to
-- 1-255. Added Wireless Interface SSID
-- table. Added new value for ethernet
-- interface speed and transmission mode.
-- Deprecated old security table. Added
-- new security table to allow security
-- configuration per wireless NIC.
-- Deprecated VLAN table since now VLAN
-- is configured in the SSID table.
-- Deprecated system inventory management
-- component interface table.
--=============================================================================
-- v3.37.1 June 03 DRB, Proxim Added wireless capability object.
-- 2003 Changed oriSyslogHeartbeat to
-- oriSyslogHeartbeatStatus.
--=============================================================================
-- v3.38.0 May 16 DRB, Proxim Added RAD Security Group. Added SNMPv3
-- 2003 mgmt objects. Deprecated data rate
-- objects in remote link test table and
-- added new table for link test data
-- rates. Added new value for TFTP file
-- type to support SSL feature. Added SSL
-- objects to the HTTP group.
-- Added 802.11g value to monitoring
-- station statistics MACProtocol type.
--=============================================================================
-- v3.39.0 June 03 DRB, Proxim Added object to system group for
-- 2003 configuration of the country code.
-- Added load balancing objects to
-- wireless interface properties table.
-- Added security mode, broadcast SSID,
-- and closed system to SSID table.
-- Added UPSD group and relevant objects.
--=============================================================================
-- v3.40.0 June 05 DRB, Proxim Added object to system group for
-- 2003 IBSS power control. Changed default
-- value of Link Test time out object.
--=============================================================================
-- v3.41.0 June 12 DRB, Proxim Added values to the SSID Table for
-- 2003 security configuration object. Added
-- objects security configuration table
-- and deprecated objects that are no
-- longer required. Corrected name of the
-- IBSSPowerControl object.
--=============================================================================
-- v3.42.0 June 27 DRB, Proxim Added mgmt objects and trap for the
-- 2003 Auto config feature for release 2.4.
--=============================================================================
-- v3.43.0 July 08 DRB, Proxim Added trap for an invalid digital
-- 2003 signature when a softwre image is
-- loaded on the access point. Added enum
-- value to RADIUS Server Type. Changed
-- range for RADInterval Object. Added
-- system location object and component
-- ELIN for Lite AP.
--=============================================================================
-- v3.44.0 July 18 DRB, Proxim Added range definition to following
-- 2003 tables indices:
-- - oriSyslogHostTableIndex
-- - oriSNMPAccessTableIndex
-- - oriSNMPTrapHostTableIndex
-- - oriProtocolFilterTableIndex
-- - oriAccessControlTableIndex
-- - oriStaticMACAddressFilterTableIndex
-- - oriBroadcastFilteringTableIndex
-- - oriRADIUSAuthServerTableIndex
-- - oriRADIUSAcctServerTableIndex
-- - oriLinkTestTableIndex
-- - oriLinkIntTableIndex
-- - oriDHCPServerIPPoolTableIndex
-- Added static WEP keys objects to SSID
-- table.
--=============================================================================
-- v3.45.0 July 28 DRB, Proxim Removed System Location. Added
-- 2003 encryption key length table to SSID
-- table. Modified values for security
-- mode in SSID table. Added ACS
-- frequency band configuration to
-- wireless interface table. Removed ELIN
-- component object.
--=============================================================================
-- v3.46.0 Aug 05 DRB, Proxim Decprecated Encryption Status object
-- 2003 in the SSID table. Updated contact
-- info in the module identity.
--=============================================================================
-- v3.47.0 Aug 19 DRB, Proxim Added total number of clients object
-- 2003 to stations statistics group.
--=============================================================================
-- v3.48.0 Sept 11 DRB, Proxim Changed the name of IBSS Power Control
-- 2003 object to Tx Power Control.
--=============================================================================
-- v3.49.0 Sept 18 DRB, Proxim Added definition for Flanker Pro Dual
-- 2003 radio system OID.
--=============================================================================
-- v3.49.1 Oct 28 DRB, Proxim Added PSK Value and PSK Passphrase
-- 2003 objects to wireless interface SSID
-- table.
--=============================================================================
-- v3.49.2 Oct 31 DRB, Proxim Changed the range and default value of
-- 2003 the RADIUS authorization lifetime obj.
--=============================================================================
-- v3.49.3 Nov 03 DRB, Proxim Deprecated Wireless Interface security
-- 2003 table and its elements, since the
-- Wireless Interface SSID table will be
-- used to configure the security objs.
--=============================================================================
-- v3.49.4 Nov 11 DRB, Proxim Added traps for last known good
-- 2003 configuration file. Added WDS Security
-- table and table objects. Added object
-- wireless interface properties table for
-- enabling/disabling security per SSID.
--=============================================================================
-- v3.50.0 Nov 17 DRB, Proxim Updated FP2 and FP1 product names.
-- 2003
--=============================================================================
-- v3.51.0 Dec 01 DRB, Proxim Removed security per SSID status object
-- 2003 from SSID table and security config
-- table. Changed status of encryption
-- key objects from read-write to
-- read-create. Removed encryption status
-- object from SSID table since not used.
-- Corrected range for the wireless if
-- load balancing objects. Deprecated
-- objects in the security config table
-- since not supported anymore.
--=============================================================================
-- v3.52.0 Dec 05 DRB, Proxim Updated RAD Interval description to
-- 2003 include the units. Added default value
-- for Wireless Interface ACS Band scan
-- objected. Corrected definition of
-- WEPKeyType textual convention. Changed
-- enumeration of WDS Security mode.
--=============================================================================
-- v3.53.0 Dec 29 DRB, Proxim Added WORP Satellite Subgroups.
-- 2003 Updated description for System Event
-- log object for OR-2000. Changed and
-- added values in System Feature Table.
-- Changed status of Link Test group from
-- deprecated to current since still
-- supported by some ORiNOCO products.
--=============================================================================
-- v3.54.0 Jan 05 DRB, Proxim Modifications made to rekeying interval
-- 2004 range in the Wireless Interface SSID
-- table. Defined range for IP TTL obj.
--=============================================================================
-- v3.55.0 Jan 16 DRB, Proxim Added object to wireless interface
-- 2004 properties table for enabling/disabling
-- security per SSID. Changed the range
-- of the Telnet login and session idle
-- timeouts. Changed the default value
-- of the login timeout to 60 seconds.
-- Upadated descriptions of WORP Interface
-- DDRS objects.
--=============================================================================
-- v3.56.0 Jan 22 DRB, Proxim Added three objects to WORP Stat Table:
-- 2004 - Local Tx Rate
-- - Remote Tx Rate
-- - Table Index
-- Added two new subgroups to WORP If:
-- - orinocoWORPIfBSU
-- - orinocoWORPIfBSUStat
-- Added objects to WORP If Stat group:
-- - MAC Address
-- - Local Tx Rate
-- - Remote Tx Rate
-- - Average Local Signal
-- - Average Local Noise
-- - Average Remote Signal
-- - Average Remote Noise
--=============================================================================
-- v3.57.0 Feb 03 DRB, Proxim Added object to SSID table for deny
-- 2004 non encrypted data functionality.
--=============================================================================
-- v3.58.0 Mar 10 DRB, Proxim Added enums to the oriTFTPFileType
-- 2004 object. Added the following new objs
-- and traps for CLI Batch feature:
-- - oriTrapVarBatchCliFilename
-- - oriTrapVarBatchCliMessage
-- - oriTrapVarBatchCliLineNo
-- - oriTrapBatchExecFailure
-- - oriTrapBatchFileExecStart
-- - oriTrapBatchFileExecEnd
-- Added the following objs to the Telnet
-- group for SSH feature:
-- - oriTelnetSSHStatus
-- - oriTelnetSSHHostKeyStatus
-- - oriTelnetSSHFingerPrint
-- - oriTelnetRADIUSAccessControl
-- Added oriHTTPRADIUSAccessControl to
-- HTTP group. Changed syntax of
-- spectralink status object to ObjStatus.
-- Added object for spectralink legacy
-- support. Added RAD Scan mgmt objs per
-- FSD. Added Wireless System Shutdown
-- mgmt objs per FSD. Added the following
-- objs to the security group:
-- - oriSecurityHwConfigResetStatus
-- - oriSecurityConfigurationResetPassword
-- Added the following objs to the RADIUS
-- group:
-- - oriRADIUSLocalUserStatus
-- - oriRADIUSLocalUserPassword
-- Added oriRADIUSAcctUpdateInterval to
-- RADIUS accounting group. Added
-- security profile table to security
-- group. As a result relevant objs in
-- the wireless interface SSID table were
-- deprecated. Added RADIUS server
-- profile table to RADIUS group. As a
-- result relevant objs in the previous
-- RADIUS Auth and Acct tables were
-- deprecated. Added the following two
-- objects to wireless interface
-- properties table:
-- - oriWirelessIfSupportedAuthenticationModes
-- - oriWirelessIfSupportedCipherModes
--=============================================================================
-- v3.59.0 Mar 19 DRB, Proxim Added object to wireless interface
-- 2004 properties table for TPC. Added
-- security gateway group for TMP 11
-- device. Corrected range and value of
-- WORP DDRS objects. Added required objs
-- to WORP Roaming group.
-- Added trap for SSH Initialization
-- failure. Changed range of RADIUS
-- Authorization Lifetime object.
-- Deprecated RADIUS Server Auth and Acct
-- tables since RADIUS Server Profile
-- table will now be used. Added object
-- for configuring the RADIUS based
-- management access RADIUS server
-- profile.
--=============================================================================
-- v3.60.0 April 06 DRB, Proxim Changed the name of wireless antenna
-- 2004 diverity management object. Added
-- varbind to CLI Batch File Executed
-- trap. Added description object to
-- RADIUS server profile table.
--=============================================================================
-- v3.61.0 April 08 DRB, Proxim Added management objects for QoS/WME
-- 2004 feature.
--=============================================================================
-- v3.62.0 May 11 DRB, Proxim Added new country codes to the system
-- 2004 country code object.
--=============================================================================
-- v3.63.0 May 17 DRB, Proxim Added Traps for DHCP renewal and VLAN
-- 2004 ID assignment by RADIUS server.
-- Added objects to SSID table for:
-- - SSID Authorization
-- - MAC Access Control
-- - RADIUS based MAC Access Control
-- - Accounting Status
-- Deprecated scalar objects that were
-- introduced in SSID table.
-- Made changes to Rogue Scan group and
-- results table.
-- Changed range for RADIUS Accounting
-- update object.
-- Made changes to CLI Batch file traps.
-- Added object to select whih security
-- profile will use four WEP keys.
-- Added object for QoS/WME admission
-- control maximum medium threshold.
--=============================================================================
-- v3.64.0 May 24 DRB, Proxim Removed RADIUS Profile description
-- 2004 object. Corrected typo on RADIUS
-- Accounting Status object in Wireless If
-- SSID table. Changed the name of the
-- Watch Dog Timer Trap to Unrecoverable
-- Software Error Trap and updated the
-- description (RFC 11911). Removed
-- create(4) from the Link Intergrity
-- Table Status object since this table
-- has a static number of entries and the
-- admin can not create an entry (RFC
-- 12917). Enhanced the description in
-- the security profile table specifying
-- wireless STA types and authentication
-- and cipher modes for each the different
-- wirless STA types.
--=============================================================================
-- v3.65.0 May 24 DRB, Proxim Added variable binding for Device
-- 2004 Rebooting trap to provide information
-- on whether a manual reboot was issued
-- (RFC 10762).
--=============================================================================
-- v3.66.0 June 09 DRB, Proxim Added object to SSID table for
-- 2004 selecting QoS Policy. Changed the name
-- of the CommentString textual convention
-- to DisplayString80. Correct spelling
-- on country name.
--=============================================================================
-- v3.67.0 June 16 DRB, Proxim Added DisplayString55 as textual
-- 2004 convention. Changed or2000 product
-- name to tmp11. Added orinocoTempLog
-- subgroup and relevant objects to that
-- group. Added new country codes
-- to the system country code object.
-- Added object to system group to
-- identify the hardware type.
-- Changed objects in
-- oriWirelessIfSecurityTable to current.
-- Modified definition of
-- oriWirelessIfEncryptionOptions.
-- Changed objects in
-- orinocoRADIUSAuth and orinocoRADIUSAcct
-- to current. Changed range for
-- RADIUS authorization liftetime object.
-- Added eventlog and templog to TFTP File
-- type object. Added trap to indicate
-- a temperature alert. Modified
-- description of interface bitmask obj to
-- include TMP 11. Changed TPCMode object
-- to integer32 and modified the range.
-- Removed objects from WORPIfConfigTable
-- that were not used and added one obj.
-- Added size definition for SSID obj in
-- Wireless interface SSID table.
--=============================================================================
-- Version: 3.68.0
-- Date: July 16, 2004
-- Author: Daniel R. Borges - Proxim Corporation
-- Changes:
-- Removed rekeying interval object from security profile table.
-- Changed status of rekeing object in SSID to current.
-- Specified size for PSK passphrase and PSK value.
-- Added varbind to reboot trap in order to provide the number of seconds
-- until the next reboot.
--=============================================================================
-- Version: 3.69.0
-- Date: July 16, 2004
-- Author: Daniel R. Borges - Proxim Corporation
-- Changes:
-- Added antenna gain object to wireless interface table.
-- Deprecated old antenna gain object in wireless interface table.
-- Added TFTP downgrade object to TFTP group.
--=============================================================================
-- Version: 3.70.0
-- Date: July 23, 2004
-- Author: Daniel R. Borges - Proxim Corporation
-- Changes:
-- Changed RAD Last Scan Time object data type to TimeTicks (MR 17199).
-- Created textual convention for DisplayString32.
-- Changed QoS Policy name to DisplayString32.
-- Changed SSH Trap initialization failure to initialization status.
-- Added varbind to SSH Trap initialization status.
-- Enhanced description of DisplayString55.
-- Fixed naming convention of 802.1p to 802.1D mapping table and IP DSCP
-- to 802.1D mapping table.
-- Changed QoS Policy type object to read-only.
-- Changed AuthMode and CipherMode in security profile table to read-only.
--=============================================================================
-- Version: 3.71.0
-- Date: August 6, 2004
-- Author: Daniel R. Borges - Proxim Corporation
-- Changes:
-- Changed TFTPFiletype enumeration for CLI batch file log (MR 17326).
-- Changed PSK value in security profile table to DisplayString (MR 16331).
--=============================================================================
--
-- COMPILERS: NuDesign, MG-Soft, VxWorks, and HP-OpenView MIB Compilers
--
--=============================================================================
--=============================================================================
-- Copyright (C) 2004 Proxim Corporation
-- Proxim Corporation - PROPRIETARY
-- Disclosure to third parties or reproduction in any from
-- whatsoever, without prior written consent, is strictly forbiden.
--=============================================================================
--=============================================================================
-- ORiNOCO MIB Begin
--=============================================================================
ORiNOCO-MIB DEFINITIONS ::= BEGIN
--=============================================================================
-- ORiNOCO MIB Imports
--=============================================================================
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, OBJECT-IDENTITY,
enterprises, IpAddress, Counter32, Gauge32, TimeTicks, Integer32,
Counter64
FROM SNMPv2-SMI
DisplayString, PhysAddress, MacAddress, TruthValue, TimeStamp,
TimeInterval, DateAndTime, RowStatus, TEXTUAL-CONVENTION
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
ifIndex
FROM RFC1213-MIB;
--=============================================================================
-- ORiNOCO MIB Module Identity: orinoco
--=============================================================================
orinoco MODULE-IDENTITY
LAST-UPDATED "0408100000Z"
ORGANIZATION "Proxim Corporation"
CONTACT-INFO
"Daniel R. Borges
Proxim Corporation
WiFi Research and Development
935 Stewart Drive
Sunnyvale, CA 94085
USA
Tel: +1.408.731.2654
Fax: +1.408.731.3673
Email: drborges@proxim.com"
DESCRIPTION
"MIB Definition used in the ORiNOCO Wireless Product Line:
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).
agere(11898).orinoco(2)"
::= { agere 2 }
--=============================================================================
-- Definition of Textual Conventions
--=============================================================================
VlanId ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A 12-bit VLAN ID used in the VLAN Tag header."
SYNTAX Integer32 (-1..4094)
InterfaceBitmask ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An Interface Bitmask used to enable or disable access or
functionality of an interface in the system. Each bit in this
object represents a network interface in the system consistent
with the ifIndex object in MIB-II. The value for this object is
interpreted as a bitfield, where the value of 1 means enabled.
Examples of Usage:
1. For a system with the following interfaces (AP-2000 & AP-4000):
- Ethernet If = 1
- Loopback If = 2
- Wireless If A = 3
- Wireless If B = 4
Interface Bitmask usage:
- 00000000 (0x00): All Interfaces disabled
- 00000001 (0x01): Ethernet If enabled
- 00000010 (0x02): All Interfaces disabled
- 00000011 (0x03): Ethernet If enabled
- 00000100 (0x04): Wireless If A enabled
- 00000110 (0x06): Wireless If A enabled
- 00001000 (0x08): Wireless If B enabled
- 00001010 (0x0A): Wireless If B enabled
- 00001101 (0x0D): All Interfaces enabled
- 00001111 (0x0F): All Interfaces enabled (see Note)
Note: The software loopback interface bit is ignored in the
usage of the interface bitmask object.
2. For a system with the following interfaces (AP-600, AP-700 &
Tsunami Multipoint Devices):
- Ethernet If = 1
- Loopback If = 2
- Wireless If A = 3
Interface Bitmask usage:
- 00000000 (0x00): All Interfaces disabled
- 00000001 (0x01): Ethernet If enabled
- 00000010 (0x02): All Interfaces disabled
- 00000011 (0x03): Ethernet If enabled
- 00000100 (0x04): Wireless If A enabled
- 00000101 (0x05): All Interfaces enabled
- 00000110 (0x06): Wireless If A enabled
- 00000111 (0x07): All Interfaces enabled (see Note)
Note: The software loopback interface bit is ignored in the
usage of the interface bitmask object.
3. For a system with the following interfaces (BG-2000):
- Ethernet WAN If = 1
- Ethernet LAN If = 2
- Wireless If A = 3
Inteface Bitmask usage:
- 00000000 (0x00): all Interfaces disabled
- 00000001 (0x01): Ethernet WAN If enabled
- 00000010 (0x02): Ethernet LAN If enabled
- 00000011 (0x03): Ethernet WAN and LAN If enabled
- 00000100 (0x04): Wireless If A enabled
- 00000101 (0x05): Ethernet WAN and Wireless If A enabled
- 00000110 (0x06): Ethernet LAN and Wireless If A enabled
- 00000111 (0x07): All Interfaces enabled"
SYNTAX Integer32 (0..255)
ObjStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The status textual convention is used to enable or disable
functionality or a feature."
SYNTAX INTEGER
{
enable(1),
disable(2)
}
WEPKeyType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The WEPKeyType textual convention is used to define the object
type used to configured WEP Keys."
SYNTAX DisplayString (SIZE(0..32))
ObjStatusActive ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The status textual convention is used to activate, deactivate, and
delete a table row."
SYNTAX INTEGER
{
active(1),
inactive(2),
deleted(3)
}
DisplayString80 ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The DisplayString80 textual convention is used to define a
string that can consist of 0 - 80 alphanumeric characters."
SYNTAX DisplayString (SIZE(0..80))
DisplayString55 ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The DisplayString55 textual convention is used to define a
string that can consist of 0 - 55 alphanumeric characters this textual
convention is used for Temperature log messages."
SYNTAX DisplayString (SIZE(0..55))
DisplayString32 ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The DisplayString32 textual convention is used to define a
string that can consist of 0 - 32 alphanumeric characters."
SYNTAX DisplayString (SIZE(0..32))
--=============================================================================
-- Definition of Agere MIB OID Tree
--=============================================================================
agere OBJECT IDENTIFIER ::= { enterprises 11898 }
--=============================================================================
-- Definition of the ORiNOCO MIB Objects: orincoObjects
--=============================================================================
orinocoObjects OBJECT IDENTIFIER ::= { orinoco 1 }
--=============================================================================
-- Definition of the ORiNOCO Notifications: orinocoNotifications
--=============================================================================
orinocoNotifications OBJECT IDENTIFIER ::= { orinoco 2 }
--=============================================================================
-- Definition of the ORiNOCO Conformance: orinocoConformance
--=============================================================================
orinocoConformance OBJECT IDENTIFIER ::= { orinoco 3 }
orinocoGroups OBJECT IDENTIFIER ::= { orinocoConformance 1 }
orinocoCompliances OBJECT IDENTIFIER ::= { orinocoConformance 2 }
--=============================================================================
-- Definition of the ORiNOCO Products: orinocoProducts
--=============================================================================
orinocoProducts OBJECT IDENTIFIER ::= { orinoco 4 }
ap1000 OBJECT IDENTIFIER ::= { orinocoProducts 1 }
rg1000 OBJECT IDENTIFIER ::= { orinocoProducts 2 }
as1000 OBJECT IDENTIFIER ::= { orinocoProducts 3 }
as2000 OBJECT IDENTIFIER ::= { orinocoProducts 4 }
ap500 OBJECT IDENTIFIER ::= { orinocoProducts 5 }
ap2000 OBJECT IDENTIFIER ::= { orinocoProducts 6 }
bg2000 OBJECT IDENTIFIER ::= { orinocoProducts 7 }
rg1100 OBJECT IDENTIFIER ::= { orinocoProducts 8 }
tmp11 OBJECT IDENTIFIER ::= { orinocoProducts 9 }
ap600 OBJECT IDENTIFIER ::= { orinocoProducts 10 }
ap2500 OBJECT IDENTIFIER ::= { orinocoProducts 11 }
ap4000 OBJECT IDENTIFIER ::= { orinocoProducts 12 }
ap700 OBJECT IDENTIFIER ::= { orinocoProducts 13 }
--=============================================================================
-- Definition of the ORiNOCO MIB Object Groups and Subgroups
--=============================================================================
-- System Group and System Inventory Management Group
orinocoSys OBJECT IDENTIFIER ::= { orinocoObjects 1 }
-- Interface Group
orinocoIf OBJECT IDENTIFIER ::= { orinocoObjects 2 }
-- Network Group
orinocoNet OBJECT IDENTIFIER ::= { orinocoObjects 3 }
-- SNMP Group
orinocoSNMP OBJECT IDENTIFIER ::= { orinocoObjects 4 }
-- Filtering Group
orinocoFiltering OBJECT IDENTIFIER ::= { orinocoObjects 5 }
-- Remote Authentication Dial In User Service Group
orinocoRADIUS OBJECT IDENTIFIER ::= { orinocoObjects 6 }
-- Telnet Group
orinocoTelnet OBJECT IDENTIFIER ::= { orinocoObjects 7 }
-- TFTP Group
orinocoTFTP OBJECT IDENTIFIER ::= { orinocoObjects 8 }
-- Serial Group
orinocoSerial OBJECT IDENTIFIER ::= { orinocoObjects 9 }
-- Inter-Access Point Protocol Group
orinocoIAPP OBJECT IDENTIFIER ::= { orinocoObjects 10 }
-- Link Test Group
orinocoLinkTest OBJECT IDENTIFIER ::= { orinocoObjects 11 }
-- Link Integrity Group
orinocoLinkInt OBJECT IDENTIFIER ::= { orinocoObjects 12 }
-- Uplink Power Saving Devices Group
orinocoUPSD OBJECT IDENTIFIER ::= { orinocoObjects 13 }
-- Quality of Service (QoS) Group
orinocoQoS OBJECT IDENTIFIER ::= { orinocoObjects 14 }
-- Dynamic Host Configuration Protocol Group
orinocoDHCP OBJECT IDENTIFIER ::= { orinocoObjects 15 }
-- HTTP (web) Group
orinocoHTTP OBJECT IDENTIFIER ::= { orinocoObjects 16 }
-- WDS Group
orinocoWDS OBJECT IDENTIFIER ::= { orinocoObjects 17 }
-- Traps Group
orinocoTrap OBJECT IDENTIFIER ::= { orinocoObjects 18 }
-- IP/ARP Group
orinocoIPARP OBJECT IDENTIFIER ::= { orinocoObjects 19 }
-- Spanning Tree Group
orinocoSpanningTree OBJECT IDENTIFIER ::= { orinocoObjects 20 }
-- Security Group
orinocoSecurity OBJECT IDENTIFIER ::= { orinocoObjects 21 }
-- PPPoE Group
orinocoPPPoE OBJECT IDENTIFIER ::= { orinocoObjects 22 }
-- Configuration Group
orinocoConfig OBJECT IDENTIFIER ::= { orinocoObjects 23 }
-- DNS Group
orinocoDNS OBJECT IDENTIFIER ::= { orinocoObjects 24 }
-- AOL Group
orinocoAOL OBJECT IDENTIFIER ::= { orinocoObjects 25 }
-- NAT Group
orinocoNAT OBJECT IDENTIFIER ::= { orinocoObjects 26 }
-- SpectraLink VoIP Group
orinocoSpectraLink OBJECT IDENTIFIER ::= { orinocoObjects 29 }
-- VLAN Group
orinocoVLAN OBJECT IDENTIFIER ::= { orinocoObjects 30 }
-- DMZ Group
orinocoDMZ OBJECT IDENTIFIER ::= { orinocoObjects 31 }
-- OEM Group
orinocoOEM OBJECT IDENTIFIER ::= { orinocoObjects 32 }
-- Station Statistics Group
orinocoStationStatistics OBJECT IDENTIFIER ::= { orinocoObjects 33 }
-- Simple Network Time Protocol Group
orinocoSNTP OBJECT IDENTIFIER ::= { orinocoObjects 34 }
--=============================================================================
-- Definition of the System Subgroups
--=============================================================================
-- System Inventory Management Subgroup
orinocoSysInvMgmt OBJECT IDENTIFIER ::= { orinocoSys 1 }
-- System Feature based License Subgroup
orinocoSysFeature OBJECT IDENTIFIER ::= { orinocoSys 19 }
-- System Log (Syslog) Subgroup
orinocoSyslog OBJECT IDENTIFIER ::= { orinocoSys 21 }
-- System Temperature Log Subgroup
orinocoTempLog OBJECT IDENTIFIER ::= { orinocoSys 23 }
--=============================================================================
-- Definition of the Interface Subgroups
--=============================================================================
-- Wireless Interface Subgroup
orinocoWirelessIf OBJECT IDENTIFIER ::= { orinocoIf 1 }
-- Ethernet Interface Subgroup
orinocoEthernetIf OBJECT IDENTIFIER ::= { orinocoIf 2 }
-- WORP Interface Subgroup
orinocoWORPIf OBJECT IDENTIFIER ::= { orinocoIf 5 }
--=============================================================================
-- Definition of the WORP Satellite Subgroups
--=============================================================================
-- This subgroup is only used for performing per-Sat config or per-Sat
-- statistics on the base station.
orinocoWORPIfSat OBJECT IDENTIFIER ::= { orinocoWORPIf 3 }
-- This subgroup is only used for Site Survey Mode.
orinocoWORPIfSiteSurvey OBJECT IDENTIFIER ::= { orinocoWORPIf 4 }
-- This subgroup is only used for WORP Roaming.
orinocoWORPIfRoaming OBJECT IDENTIFIER ::= { orinocoWORPIf 5 }
-- This subgroup is only used for WORP DDRS.
orinocoWORPIfDDRS OBJECT IDENTIFIER ::= { orinocoWORPIf 6 }
-- This subgroup is only used for doing BSU statistics on the SU/RSU station.
orinocoWORPIfBSU OBJECT IDENTIFIER ::= { orinocoWORPIf 7 }
-- WORP Interface Satellite Config Subgroup
orinocoWORPIfSatConfig OBJECT IDENTIFIER ::= { orinocoWORPIfSat 1 }
-- WORP Interface Satellite Statistics Subgroup
orinocoWORPIfSatStat OBJECT IDENTIFIER ::= { orinocoWORPIfSat 2 }
-- WORP Interface BSU Statistics Subgroup
orinocoWORPIfBSUStat OBJECT IDENTIFIER ::= { orinocoWORPIfBSU 1 }
--=============================================================================
-- Definition of the Network Subgroups
--=============================================================================
-- IP Network Subgroup
orinocoNetIP OBJECT IDENTIFIER ::= { orinocoNet 1 }
--=============================================================================
-- Definition of the RADIUS Subgroups
--=============================================================================
-- RADIUS Authentication Subgroup
orinocoRADIUSAuth OBJECT IDENTIFIER ::= { orinocoRADIUS 1 }
-- RADIUS Accounting Subgroup
orinocoRADIUSAcct OBJECT IDENTIFIER ::= { orinocoRADIUS 2 }
-- RADIUS Server Profile Subgroup
orinocoRADIUSSvrProfiles OBJECT IDENTIFIER ::= { orinocoRADIUS 10 }
--=============================================================================
-- Definition of the Filtering Subgroups
--=============================================================================
-- Protocol Filtering Subgroup
orinocoProtocolFilter OBJECT IDENTIFIER ::= { orinocoFiltering 1 }
-- Access Control Filter Subgroup
orinocoAccessControl OBJECT IDENTIFIER ::= { orinocoFiltering 2 }
-- Static MAC Address Filter Subgroup
orinocoStaticMACAddressFilter
OBJECT IDENTIFIER ::= { orinocoFiltering 3 }
-- Storm Threshold Filter Subgroup
orinocoStormThreshold OBJECT IDENTIFIER ::= { orinocoFiltering 4 }
-- IP Packet and Port Filtering Subgroup
orinocoPortFilter OBJECT IDENTIFIER ::= { orinocoFiltering 5 }
-- Advanced Bridging Filter Subgroup
orinocoAdvancedFiltering OBJECT IDENTIFIER ::= { orinocoFiltering 6 }
-- Packet Forwarding Subgroup
orinocoPacketForwarding OBJECT IDENTIFIER ::= { orinocoFiltering 7 }
-- IBSS Traffic Control Subgroup
orinocoIBSSTraffic OBJECT IDENTIFIER ::= { orinocoFiltering 8 }
-- IntraCellBlocking Subgroup
orinocoIntraCellBlocking OBJECT IDENTIFIER ::= { orinocoFiltering 9 }
-- TMP 11 Packet Forwarding to Security Gateway Subgroup
orinocoSecurityGw OBJECT IDENTIFIER ::= { orinocoFiltering 10 }
--=============================================================================
-- Definition of the DHCP Subgroups
--=============================================================================
-- DHCP Server Subgroup
orinocoDHCPServer OBJECT IDENTIFIER ::= { orinocoDHCP 1 }
-- DHCP Client Subgroup
orinocoDHCPClient OBJECT IDENTIFIER ::= { orinocoDHCP 2 }
-- DHCP Relay Agent Subgroup
orinocoDHCPRelay OBJECT IDENTIFIER ::= { orinocoDHCP 3 }
--=============================================================================
-- Definition of the DNS Subgroups
--=============================================================================
-- DNS Client Subgroup
orinocoDNSClient OBJECT IDENTIFIER ::= { orinocoDNS 5 }
--=============================================================================
-- Definition of the Security Subgroups
--=============================================================================
-- Rogue AP Detection (RAD) Subgroup
orinocoRAD OBJECT IDENTIFIER ::= { orinocoSecurity 4 }
-- Rogue Scan Subgroup
orinocoRogueScan OBJECT IDENTIFIER ::= { orinocoSecurity 8 }
--=============================================================================
-- The System Group: orinocoSys
--=============================================================================
oriSystemReboot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to reboot the device. The value assigned
to this object is the number of seconds until the next reboot."
::= { orinocoSys 4 }
oriSystemContactEmail OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to identify the email address of the
contact person for this managed device."
::= { orinocoSys 5 }
oriSystemContactPhoneNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to identify the phone number of the
contact person for this managed device."
::= { orinocoSys 6 }
oriSystemFlashUpdate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this variable is set, all the objects that are
to be comitted to flash will be written to flash. This
will be done immediately after the value is set, regardless
of the value set."
::= { orinocoSys 7 }
oriSystemFlashBackupInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for the backup time interval for flash
memory to be udpated."
::= { orinocoSys 8 }
oriSystemEmergencyResetToDefault OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to reset the device to factory default
values. When this variable is set to 1, all the objects shall be
set to factory default values. The default value for this object
should be 0."
DEFVAL { 0 }
::= { orinocoSys 9 }
oriSystemMode OBJECT-TYPE
SYNTAX INTEGER
{
bridge(1),
gateway(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the mode the system is configured to
operate in, either bridge or gateway/router mode."
DEFVAL { bridge }
::= { orinocoSys 10 }
oriSystemEventLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriSystemEventLogTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains system event log information that can include
events, errors, and informational messages. This is a circular
buffer with a limit 100 entries."
::= { orinocoSys 11 }
oriSystemEventLogTableEntry OBJECT-TYPE
SYNTAX OriSystemEventLogTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the system event log
table."
INDEX { oriSystemEventLogMessage }
::= { oriSystemEventLogTable 1 }
OriSystemEventLogTableEntry ::=
SEQUENCE
{
oriSystemEventLogMessage DisplayString
}
oriSystemEventLogMessage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to store system event log information.
This is also used as the index to the table."
::= { oriSystemEventLogTableEntry 1 }
oriSystemEventLogTableReset OBJECT-TYPE
SYNTAX Integer32 (1..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to reset/clear the event log table. When
this object is the set all entries in the event log table are
deleted/cleared."
::= { orinocoSys 12 }
oriSystemEventLogMask OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to control what events will be logged by
the event log facility. It is a mask, each bit is used to
enable/disable a corresponding set of log messages.
The OR2000 uses the standard syslog priorities and facilities.
The Mask should only be set to mask specific facilities.
The facilities are:
LOG_KERN (0<<3) kernel messages
LOG_USER (1<<3) random user-level messages
LOG_MAIL (2<<3) mail system
LOG_DAEMON (3<<3) system daemons
LOG_AUTH (4<<3) authorization messages
LOG_SYSLOG (5<<3) messages generated internally by syslogd
LOG_LPR (6<<3) line printer subsystem
LOG_NEWS (7<<3) network news subsystem
LOG_UUCP (8<<3) UUCP subsystem
LOG_CRON (9<<3) clock daemon
LOG_AUTHPRIV (10<<3) authorization messages (private)
LOG_FTP (11<<3) ftp daemon
LOG_NTP (12<<3) NTP subsystem
LOG_SECURITY (13<<3) security subsystems (firewalling, etc.)
LOG_CONSOLE (14<<3) /dev/console output
- other codes through 15 reserved for system use
LOG_LOCAL0 (16<<3) reserved for local use
LOG_LOCAL1 (17<<3) reserved for local use
LOG_LOCAL2 (18<<3) reserved for local use
LOG_LOCAL3 (19<<3) reserved for local use
LOG_LOCAL4 (20<<3) reserved for local use
LOG_LOCAL5 (21<<3) reserved for local use
LOG_LOCAL6 (22<<3) reserved for local use
LOG_LOCAL7 (23<<3) reserved for local use
On the BG2000:
Each nibble (4 bits == 1 hex digit == a nibble) represents a
category of log messages. There are 4 levels of messages per
category (1 bit per level per category). The least significant
bit is a higher priority message.
As follows:
security - nibble 1, bits 1-4
errors - nibble 2, bits 5-8
system startup - nibble 3, bits 9-12
warnings - nibble 4, bits 13-16
information - nibble 5, bits 17-20
0x00000 - No events will be logged.
0x000F0 - Only errors will be logged.
0x0F0F0 - Warnings and errors will be logged.
0xFFFFF - All events will be logged."
::= { orinocoSys 13 }
oriSystemAccessUserName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the system access user name for the
supported management interfaces (Telnet and HTTP)."
::= { orinocoSys 14 }
oriSystemAccessPassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the system access password for the
supported management interfaces (Telnet and HTTP). This object
should be treated as write-only and returned as asterisks."
::= { orinocoSys 15 }
oriSystemAccessLoginTimeout OBJECT-TYPE
SYNTAX Integer32 (0..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the login timeout in seconds. The
default value should be 60 seconds (1 minute)."
DEFVAL { 60 }
::= { orinocoSys 16 }
oriSystemAccessIdleTimeout OBJECT-TYPE
SYNTAX Integer32 (0..36000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the inactivity or idle timeout in
seconds. The default value should be 900 seconds (15 minutes)."
DEFVAL { 900 }
::= { orinocoSys 17 }
oriSystemEventLogNumberOfMessages OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of messages currently stored
in the event log table."
::= { orinocoSys 18 }
oriSystemAccessMaxSessions OBJECT-TYPE
SYNTAX Integer32 (0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object controls the maximum number of simultaneous telnet,
http, and serial managmenent sessions."
::= { orinocoSys 20 }
oriSystemCountryCode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute identifies the country in which the station is
operating. The first two octets of this string is the two character
country code as described in document ISO/IEC 3166-1. Below is the
list of mapping of country codes to country names.
AL - ALBANIA
DZ - ALGERIA
AR - ARGENTINA
AM - ARMENIA
AU - AUSTRALIA
AT - AUSTRIA
AZ - AZERBAIJAN
BH - BAHRAIN
BY - BELARUS
BE - BELGIUM
BZ - BELIZE
BO - BOLIVIA
BR - BRAZIL
BN - BRUNEI DARUSSALAM
BG - BULGARIA
CA - CANADA
CL - CHILE
CN - CHINA
CO - COLOMBIA
CR - COSTA RICA
HR - CROATIA
CY - CYPRUS
CZ - CZECH REPUBLIC
DK - DENMARK
DO - DOMINICAN REPUBLIC
EC - ECUADOR
EG - EGYPT
EE - ESTONIA
FI - FINLAND
FR - FRANCE
GE - GEORGIA
DE - GERMANY
GR - GREECE
GT - GUATEMALA
HK - HONG KONG
HU - HUNGARY
IS - ICELAND
IN - INDIA
ID - INDONESIA
IR - IRAN
IE - IRELAND
I1 - IRELAND - 5.8GHz
IL - ISRAEL
IT - ITALY
JP - JAPAN
J2 - JAPAN2
JO - JORDAN
KZ - KAZAKHSTAN
KP - NORTH KOREA
KR - KOREA REPUBLIC
K2 - KOREA REPUBLIC2
KW - KUWAIT
LV - LATVIA
LB - LEBANON
LI - LIECHTENSTEIN
LT - LITHUANIA
LU - LUXEMBOURG
MO - MACAU
MK - MACEDONIA
MY - MALAYSIA
MX - MEXICO
MC - MONACO
MA - MOROCCO
NL - NETHERLANDS
NZ - NEW ZEALAND
NO - NORWAY
OM - OMAN
PK - PAKISTAN
PA - PANAMA
PE - PERU
PH - PHILIPPINES
PL - POLAND
PT - PORTUGAL
PR - PUERTO RICO
QA - QATAR
RO - ROMANIA
RU - RUSSIA
SA - SAUDI ARABIA
SG - SINGAPORE
SK - SLOVAK REPUBLIC
SI - SLOVENIA
ZA - SOUTH AFRICA
ES - SPAIN
SE - SWEDEN
CH - SWITZERLAND
SY - SYRIA
TW - TAIWAN
TH - THAILAND
TR - TURKEY
UA - UKRAINE
AE - UNITED ARAB EMIRATES
GB - UNITED KINGDOM
G1 - UNITED KINGDOM - 5.8GHz
US - UNITED STATES
UW - UNITED STATES - World
U1 - UNITED STATES - DFS
UY - URUGUAY
VE - VENEZUELA
VN - VIETNAM"
::= { orinocoSys 22 }
oriSystemHwType OBJECT-TYPE
SYNTAX INTEGER
{
indoor(1),
outdoor(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute identifies the type of TMP11 hardware i.e. Indoor
or Outdoor."
DEFVAL { indoor }
::= { orinocoSys 24 }
--=============================================================================
-- The System Inventory Management Subgroup: orinocoSysInvMgmt
--=============================================================================
oriSystemInvMgmtComponentTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriSystemInvMgmtComponentTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the inventory management objects for the
system components."
::= { orinocoSysInvMgmt 1 }
oriSystemInvMgmtComponentTableEntry OBJECT-TYPE
SYNTAX OriSystemInvMgmtComponentTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the system inventory
management component table."
INDEX { oriSystemInvMgmtTableComponentIndex }
::= { oriSystemInvMgmtComponentTable 1 }
OriSystemInvMgmtComponentTableEntry ::=
SEQUENCE
{
oriSystemInvMgmtTableComponentIndex Integer32,
oriSystemInvMgmtTableComponentSerialNumber DisplayString,
oriSystemInvMgmtTableComponentName DisplayString,
oriSystemInvMgmtTableComponentId Integer32,
oriSystemInvMgmtTableComponentVariant Integer32,
oriSystemInvMgmtTableComponentReleaseVersion Integer32,
oriSystemInvMgmtTableComponentMajorVersion Integer32,
oriSystemInvMgmtTableComponentMinorVersion Integer32
}
oriSystemInvMgmtTableComponentIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the table index."
::= { oriSystemInvMgmtComponentTableEntry 1 }
oriSystemInvMgmtTableComponentSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the system component serial number."
::= { oriSystemInvMgmtComponentTableEntry 2 }
oriSystemInvMgmtTableComponentName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the system component name."
::= { oriSystemInvMgmtComponentTableEntry 3 }
oriSystemInvMgmtTableComponentId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the system component identification."
::= { oriSystemInvMgmtComponentTableEntry 4 }
oriSystemInvMgmtTableComponentVariant OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the system component variant number."
::= { oriSystemInvMgmtComponentTableEntry 5 }
oriSystemInvMgmtTableComponentReleaseVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the system component release version
number."
::= { oriSystemInvMgmtComponentTableEntry 6 }
oriSystemInvMgmtTableComponentMajorVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the system component major version
number."
::= { oriSystemInvMgmtComponentTableEntry 7 }
oriSystemInvMgmtTableComponentMinorVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the system component minor version
number."
::= { oriSystemInvMgmtComponentTableEntry 8 }
oriSystemInvMgmtTableComponentIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriSystemInvMgmtTableComponentIfTableEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This table contains the inventory management objects for the
system components. This table has been deprecated."
::= { orinocoSysInvMgmt 2 }
oriSystemInvMgmtTableComponentIfTableEntry OBJECT-TYPE
SYNTAX OriSystemInvMgmtTableComponentIfTableEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This object represents an entry in the system component
interface table. This object has been deprecated."
INDEX { oriSystemInvMgmtTableComponentIndex,
oriSystemInvMgmtInterfaceTableIndex }
::= { oriSystemInvMgmtTableComponentIfTable 1 }
OriSystemInvMgmtTableComponentIfTableEntry ::=
SEQUENCE
{
oriSystemInvMgmtInterfaceTableIndex Integer32,
oriSystemInvMgmtInterfaceId Integer32,
oriSystemInvMgmtInterfaceRole INTEGER,
oriSystemInvMgmtInterfaceVariant Integer32,
oriSystemInvMgmtInterfaceBottomNumber Integer32,
oriSystemInvMgmtInterfaceTopNumber Integer32
}
oriSystemInvMgmtInterfaceTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object identifies the interface table index.
This object has been deprecated."
::= { oriSystemInvMgmtTableComponentIfTableEntry 1 }
oriSystemInvMgmtInterfaceId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object identifies the system component interface
identification. This object has been deprecated."
::= { oriSystemInvMgmtTableComponentIfTableEntry 2 }
oriSystemInvMgmtInterfaceRole OBJECT-TYPE
SYNTAX INTEGER
{
actor(1),
supplier(2)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object identifies the system component interface role.
This object has been deprecated."
::= { oriSystemInvMgmtTableComponentIfTableEntry 3 }
oriSystemInvMgmtInterfaceVariant OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object identifies the system component's interface
variant number. This object has been deprecated."
::= { oriSystemInvMgmtTableComponentIfTableEntry 4 }
oriSystemInvMgmtInterfaceBottomNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object identifies the system component's interface
bottom number. This object has been deprecated."
::= { oriSystemInvMgmtTableComponentIfTableEntry 5 }
oriSystemInvMgmtInterfaceTopNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object identifies the system component's interface
top number. This object has been deprecated."
::= { oriSystemInvMgmtTableComponentIfTableEntry 6 }
--=============================================================================
-- The System Feature based License Subgroup: orinocoSysFeature
--=============================================================================
oriSystemFeatureTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriSystemFeatureTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains a list of features that the current image
supports and indicates if this features is licensed (enabled) or
not (disabled). Each row represents a supported and/or licensed
feature. Supported indicates if the current image supports the
image while Licensed indicates that a license is available to use
this feature. Based on the license information in this table,
some MIB groups/subgroups/tables will be enabled or disabled."
::= { orinocoSysFeature 1 }
oriSystemFeatureTableEntry OBJECT-TYPE
SYNTAX OriSystemFeatureTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the system feature license
table."
INDEX { oriSystemFeatureTableCode }
::= { oriSystemFeatureTable 1 }
OriSystemFeatureTableEntry ::=
SEQUENCE
{
oriSystemFeatureTableCode INTEGER,
oriSystemFeatureTableSupported Integer32,
oriSystemFeatureTableLicensed Integer32,
oriSystemFeatureTableDescription DisplayString
}
oriSystemFeatureTableCode OBJECT-TYPE
SYNTAX INTEGER
{
bandwidthWiFi(1),
bandwidthWDS(2),
bandwidthWORPUp(3),
bandwidthTurboCell(4),
bandwidthADSL(5),
bandwidthCable(6),
bandwidthPhone(7),
maxStationsWiFi(8),
maxLinksWDS(9),
maxStationsWORP(10),
maxStationsTurboCell(11),
maxPPPoESessions(12),
managementHTTP(13),
remoteLinkTest(14),
routingStatic(15),
routingRIP(16),
routingOSPF(17),
spanningTreeProtocol(18),
linkIntegrity(19),
dHCPServer(20),
dHCPRelayAgent(21),
proxyARP(22),
filteringStatic(23),
authRADIUS(24),
acctRADIUS(25),
throttlingRADIUS(26),
filterIP(27),
ieee802dot1x(28),
nse(29),
iAPP(30),
dNSRedirect(31),
aOLNATGateway(32),
hereUare(33),
spectralink(34),
vLANTagging(35),
satMaxUsers(36),
bandwidthWORPDown(37),
disableSecWifiIf(38),
initialProductType(39)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the code for the licensed feature and
is used as index for this table."
::= { oriSystemFeatureTableEntry 1 }
oriSystemFeatureTableSupported OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the maximum value for the feature as
supported by the current image. For boolean features zero means
not supported, non-zero value means supported."
::= { oriSystemFeatureTableEntry 2 }
oriSystemFeatureTableLicensed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the maximum value for the feature as
enforced by the license(s). For boolean features zero means
not licensed, non-zero value means licensed."
::= { oriSystemFeatureTableEntry 3 }
oriSystemFeatureTableDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents a textual description for the licensed
feature."
::= { oriSystemFeatureTableEntry 4 }
--=============================================================================
-- The System Log (Syslog) Subgroup: orinocoSyslog
--=============================================================================
oriSyslogStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the syslog feature."
::= { orinocoSyslog 1 }
oriSyslogPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the UDP destination port number for syslog
services. The standard syslog port is 514."
::= { orinocoSyslog 2 }
oriSyslogPriority OBJECT-TYPE
SYNTAX Integer32 (1..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the lowest message priority to be logged by
the syslog service."
::= { orinocoSyslog 3 }
oriSyslogHeartbeatStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable logging of heartbeat messages
by the syslog service."
DEFVAL { disable }
::= { orinocoSyslog 4 }
oriSyslogHeartbeatInterval OBJECT-TYPE
SYNTAX Integer32 (1..604800)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure interval (in seconds) for which
heartbeat messages will be logged."
DEFVAL { 900 }
::= { orinocoSyslog 5 }
oriSyslogHostTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriSyslogHostTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to configure syslog hosts."
::= { orinocoSyslog 6 }
oriSyslogHostTableEntry OBJECT-TYPE
SYNTAX OriSyslogHostTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry for the syslog host table."
INDEX { oriSyslogHostTableIndex }
::= { oriSyslogHostTable 1 }
OriSyslogHostTableEntry ::=
SEQUENCE
{
oriSyslogHostTableIndex Integer32,
oriSyslogHostIPAddress IpAddress,
oriSyslogHostComment DisplayString,
oriSyslogHostTableEntryStatus INTEGER
}
oriSyslogHostTableIndex OBJECT-TYPE
SYNTAX Integer32 (0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents an index in the syslog host table."
::= { oriSyslogHostTableEntry 1 }
oriSyslogHostIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the IP address of the host running the
syslog daemon."
::= { oriSyslogHostTableEntry 2 }
oriSyslogHostComment OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents an optional comment for the syslog host, for
example the host name or a reference."
::= { oriSyslogHostTableEntry 3 }
oriSyslogHostTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable, disable, delete, or create an
entry in the syslog host table."
::= { oriSyslogHostTableEntry 4 }
--=============================================================================
-- The Temperature Log Subgroup: orinocoTempLog
--=============================================================================
oriUnitTemp OBJECT-TYPE
SYNTAX Integer32 (-30..60)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used for the internal unit temperature in degrees
celsius. The range of the temperature is -30 to 60 degrees celsius."
::= { orinocoTempLog 1 }
oriTempLoggingInterval OBJECT-TYPE
SYNTAX Integer32 (1..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for logging interval. The valid values
are 1,5,10,15,20,25,30,35,40,45,50,55,and 60."
DEFVAL { 5 }
::= { orinocoTempLog 2 }
oriTempLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriTempLogTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains temperature log information. This is a
circular buffer with a limit 576 entries."
::= { orinocoTempLog 3 }
oriTempLogTableEntry OBJECT-TYPE
SYNTAX OriTempLogTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the temperature log
table."
INDEX { oriTempLogMessage }
::= { oriTempLogTable 1 }
OriTempLogTableEntry ::=
SEQUENCE
{
oriTempLogMessage DisplayString55
}
oriTempLogMessage OBJECT-TYPE
SYNTAX DisplayString55
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to store temperature log information.
This is also used as the index to the table."
::= { oriTempLogTableEntry 1 }
oriTempLogTableReset OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for resetting the temperature log
table."
DEFVAL { 0 }
::= { orinocoTempLog 4 }
--=============================================================================
-- The Interface Group: orinocoIf
--=============================================================================
--=============================================================================
-- The Wireless Interface Subgroup: orinocoWirelessIf
--=============================================================================
--=============================================================================
-- The Wireless Interface Properties Table: oriWirelessIfPropertiesTable
--=============================================================================
oriWirelessIfPropertiesTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriWirelessIfPropertiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains information on the properties and
capabilities of the wireless interface(s) present in the device."
::= { orinocoWirelessIf 1 }
oriWirelessIfPropertiesEntry OBJECT-TYPE
SYNTAX OriWirelessIfPropertiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the entry in the wireless interface
properties table."
INDEX { oriWirelessIfPropertiesIndex }
::= { oriWirelessIfPropertiesTable 1 }
OriWirelessIfPropertiesEntry ::=
SEQUENCE
{
oriWirelessIfPropertiesIndex Integer32,
oriWirelessIfNetworkName DisplayString,
oriWirelessIfMediumReservation Integer32,
oriWirelessIfInterferenceRobustness INTEGER,
oriWirelessIfDTIMPeriod Integer32,
oriWirelessIfChannel Integer32,
oriWirelessIfDistancebetweenAPs INTEGER,
oriWirelessIfMulticastRate Integer32,
oriWirelessIfClosedSystem INTEGER,
oriWirelessIfAllowedSupportedDataRates OCTET STRING,
oriWirelessIfRegulatoryDomainList OCTET STRING,
oriWirelessIfAllowedChannels OCTET STRING,
oriWirelessIfMACAddress PhysAddress,
oriWirelessIfLoadBalancing INTEGER,
oriWirelessIfMediumDensityDistribution INTEGER,
oriWirelessIfTxRate Integer32,
oriWirelessIfAutoChannelSelectStatus INTEGER,
oriWirelessIfBandwidthLimitIn Gauge32,
oriWirelessIfBandwidthLimitOut Gauge32,
oriWirelessIfTurboModeStatus ObjStatus,
oriWirelessIfSupportedOperationalModes DisplayString,
oriWirelessIfOperationalMode INTEGER,
oriWirelessIfPreambleType DisplayString,
oriWirelessIfProtectionMechanismStatus ObjStatus,
oriWirelessIfSupportedMulticastRates DisplayString,
oriWirelessIfCapabilities OCTET STRING,
oriWirelessIfLBTxTimeThreshold Integer32,
oriWirelessIfLBAdjAPTimeDiffThreshold Integer32,
oriWirelessIfACSFrequencyBandScan Integer32,
oriWirelessIfSecurityPerSSIDStatus ObjStatus,
oriWirelessIfDFSStatus ObjStatus,
oriWirelessIfAntenna INTEGER,
oriWirelessIfTPCMode Integer32,
oriWirelessIfSuperModeStatus ObjStatus,
oriWirelessIfWSSStatus INTEGER,
oriWirelessIfSupportedAuthenticationModes DisplayString,
oriWirelessIfSupportedCipherModes DisplayString,
oriWirelessIfQoSStatus ObjStatus,
oriWirelessIfQoSMaxMediumThreshold Integer32,
oriWirelessIfAntennaGain Integer32
}
oriWirelessIfPropertiesIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents a unique value for each interface in the
system and is used as index to this table."
::= { oriWirelessIfPropertiesEntry 1 }
oriWirelessIfNetworkName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the network name (SSID) for this wireless
interface."
DEFVAL { "My Wireless Network" }
::= { oriWirelessIfPropertiesEntry 2 }
oriWirelessIfMediumReservation OBJECT-TYPE
SYNTAX Integer32 (0..2347)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the medium reservation value. The range
for this parameter is 0 - 2347. The medium reservation specifies
the number of octects in a frame above which a RTS/CTS handshake is
performed. The default value should be 2347, which disables
RTS/CTS mode."
DEFVAL { 2347 }
::= { oriWirelessIfPropertiesEntry 3 }
oriWirelessIfInterferenceRobustness OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables or disables the interference robustness
feature. The default value for this object should be disable."
DEFVAL { disable }
::= { oriWirelessIfPropertiesEntry 4 }
oriWirelessIfDTIMPeriod OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the delivery traffic indication map
period. This is the interval between the transmission of multicast
frames on the wireless inteface. It is expressed in the Beacon
messages. The recommended default value for this object is 1."
DEFVAL { 1 }
::= { oriWirelessIfPropertiesEntry 5 }
oriWirelessIfChannel OBJECT-TYPE
SYNTAX Integer32 (1..14)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the radio frequency channel for this
wireless interface. The default value for the channel is based on the
regulatory domain."
::= { oriWirelessIfPropertiesEntry 6 }
oriWirelessIfDistancebetweenAPs OBJECT-TYPE
SYNTAX INTEGER
{
large(1),
medium(2),
small(3),
minicell(4),
microcell(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the distance between access points.
The default value for this parameter should be large."
DEFVAL { large }
::= { oriWirelessIfPropertiesEntry 7 }
oriWirelessIfMulticastRate OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the multicast rate, but it is
dependent on the type of wireless NIC. The value of this object is
given in 500 Kbps units. This object can be configured to one of the
values defined by the supported multicast rates objects
(oriWirelessIfSupportedMulticastRates).
For 802.11b Wireless NICs:
This object identifies multicast rate of the wireless interface.
This is dependent on the distance between APs. When the distance
between APs object is set to small, minicell, or microcell the
multicast rates can be set to 11 Mbit/s (22 in 500 Kbps units),
5.5 Mbit/s (11), 2 Mbit/s (4), and 1 Mbit/s (2). When this object
is set to medium, the allowed rates are 5.5 Mbit/s (11),
2 Mbit/s (4), 1 Mbit/s (2). When this object is set to large, then
the multicast rates can be set to 2 Mbits/s (4) or 1 Mbits/s (2).
The default value for this object should be 2 Mbits/sec (4).
For 802.11a, g, and a/g Wireless NICs:
This object is used to set the multicast rate for beacons, frames
used for protection mechanism (CTS), and other multicast and broadcast
frames."
::= { oriWirelessIfPropertiesEntry 8 }
oriWirelessIfClosedSystem OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used as a flag which identifies whether the
device will accept association requests to this interface, for
client stations configured with a network name of 'ANY'. When
this object is disabled, it will accept association requests
from client stations with a network name of 'ANY'. If this
object is set to enable then the interface will only accept
association requests that match the interface's network name
(SSID). The default value for this object should be disable."
DEFVAL { disable }
::= { oriWirelessIfPropertiesEntry 9 }
oriWirelessIfAllowedSupportedDataRates OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the transmit rates supported by the
wireless interface. The values of this object are given in
units of 500 kbps.
Examples for supported data rates:
- 802.11b PHY (DSSS - 2.4 GHz)
- 0 = Auto Fallback
- 2 = 1 Mbps
- 4 = 2 Mbps
- 11 = 5.5 Mbps
- 22 = 11 Mbps
- 802.11a PHY (OFDM - 5 GHz)
- 0 = Auto Fallback
- 12 = 6 Mbps
- 18 = 9 Mbps
- 24 = 12 Mbps
- 36 = 18 Mbps
- 48 = 24 Mbps
- 72 = 36 Mbps
- 96 = 48 Mbps
- 108 = 54 Mbps
- 802.11a PHY (OFDM - 5 GHz) with Turbo Mode Enabled
- 0 = Auto Fallback
- 24 = 12 Mbps
- 36 = 18 Mbps
- 48 = 24 Mbps
- 72 = 36 Mbps
- 96 = 48 Mbps
- 144 = 72 Mbps
- 192 = 96 Mbps
- 216 = 108 Mbps
- 802.11g PHY (ERP) in 802.11g only mode
- 0 = Auto Fallback
- 12 = 6 Mbps
- 18 = 9 Mbps
- 24 = 12 Mbps
- 36 = 18 Mbps
- 48 = 24 Mbps
- 72 = 36 Mbps
- 96 = 48 Mbps
- 108 = 54 Mbps
- 802.11g PHY (ERP) in 802.11b/g mode
- 0 = Auto Fallback
- 2 = 1 Mbps
- 4 = 2 Mbps
- 11 = 5.5 Mbps
- 12 = 6 Mbps
- 18 = 9 Mbps
- 22 = 11 Mbps
- 24 = 12 Mbps
- 36 = 18 Mbps
- 48 = 24 Mbps
- 72 = 36 Mbps
- 96 = 48 Mbps
- 108 = 54 Mbps"
::= { oriWirelessIfPropertiesEntry 10 }
oriWirelessIfRegulatoryDomainList OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies a single regulatory domain (not a list) which
is supported by the wireless interface."
::= { oriWirelessIfPropertiesEntry 11 }
oriWirelessIfAllowedChannels OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the radio frequency channels that the
interface supports."
::= { oriWirelessIfPropertiesEntry 12 }
oriWirelessIfMACAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object represents the MAC address of the wireless interface
present in the device. This object has been deprecated."
::= { oriWirelessIfPropertiesEntry 13 }
oriWirelessIfLoadBalancing OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the load balancing feature
for the wireless interface."
DEFVAL { enable }
::= { oriWirelessIfPropertiesEntry 14 }
oriWirelessIfMediumDensityDistribution OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the medium density distribution
feature for the wireless interface."
DEFVAL { enable }
::= { oriWirelessIfPropertiesEntry 15 }
oriWirelessIfTxRate OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the transmit rate for unicast
traffic for the wireless interface. This object is dependent on
the transmit rates supported by the wireless interface (refer
to MIB object - oriWirelessIfAllowedSupportedDataRates and
dot11PHYType). The values of this object are given in units of
500 kbps. A value of zero (0) is interpreted as auto fallback.
Examples for configuring this object:
- 802.11b PHY (DSSS - 2.4 GHz)
- 0 = Auto Fallback
- 2 = 1 Mbps
- 4 = 2 Mbps
- 11 = 5.5 Mbps
- 22 = 11 Mbps
- 802.11a PHY (OFDM - 5 GHz)
- 0 = Auto Fallback
- 12 = 6 Mbps
- 18 = 9 Mbps
- 24 = 12 Mbps
- 36 = 18 Mbps
- 48 = 24 Mbps
- 72 = 36 Mbps
- 96 = 48 Mbps
- 108 = 54 Mbps
- 802.11a PHY (OFDM - 5 GHz) with Turbo Mode Enabled
- 0 = Auto Fallback
- 24 = 12 Mbps
- 36 = 18 Mbps
- 48 = 24 Mbps
- 72 = 36 Mbps
- 96 = 48 Mbps
- 144 = 72 Mbps
- 192 = 96 Mbps
- 216 = 108 Mbps
- 802.11g PHY (ERP) in 802.11g only mode
- 0 = Auto Fallback
- 12 = 6 Mbps
- 18 = 9 Mbps
- 24 = 12 Mbps
- 36 = 18 Mbps
- 48 = 24 Mbps
- 72 = 36 Mbps
- 96 = 48 Mbps
- 108 = 54 Mbps
- 802.11g PHY (ERP) in 802.11b/g mode
- 0 = Auto Fallback
- 2 = 1 Mbps
- 4 = 2 Mbps
- 11 = 5.5 Mbps
- 12 = 6 Mbps
- 18 = 9 Mbps
- 22 = 11 Mbps
- 24 = 12 Mbps
- 36 = 18 Mbps
- 48 = 24 Mbps
- 72 = 36 Mbps
- 96 = 48 Mbps
- 108 = 54 Mbps
The default value for this object should be zero
(0) auto fallback."
DEFVAL { 0 }
::= { oriWirelessIfPropertiesEntry 16 }
oriWirelessIfAutoChannelSelectStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the automatic frequency channel
feature for the wireless interface. If this object is enabled, the
frequency channel object can not be set, but the frequency channel
selected will be given in that object. The default value for
this object should be enable."
DEFVAL { enable }
::= { oriWirelessIfPropertiesEntry 17 }
oriWirelessIfBandwidthLimitIn OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the input bandwidth limit of the interface
in increments of 64 kbps. The value can be limited by a previous
written value, the negotiation process during registration or by a
license. A written value will only take effect after reboot."
::= { oriWirelessIfPropertiesEntry 18 }
oriWirelessIfBandwidthLimitOut OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the output bandwidth limit of the interface
in increments of 64 kbps. The value can be limited by a previous
written value, the negotiation process during registration or by a
license. A written value will only take effect after reboot."
::= { oriWirelessIfPropertiesEntry 19 }
oriWirelessIfTurboModeStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable turbo mode support. Turbo
mode is only supported for 802.11a PHY (OFDM - 5 GHz) and 802.11g
(ERP - 2.4 GHz) wireless NICs and can only be enabled when super mode
is enabled. When Turbo mode is enabled the data rates will be
doubled (refer to oriWirelessIfAllowedSupportedDataRates object
description)."
::= { oriWirelessIfPropertiesEntry 20 }
oriWirelessIfSupportedOperationalModes OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides information on the wireless operational modes
supported by the NIC. Depending on the wireless NIC in the device
different wireless operational modes can be configured.
The possible supported modes can be:
- 802.11b only
- 802.11g only
- 802.11b/g
- 802.11a only
- 802.11g-wifi"
::= { oriWirelessIfPropertiesEntry 21 }
oriWirelessIfOperationalMode OBJECT-TYPE
SYNTAX INTEGER
{
dot11b-only(1),
dot11g-only(2),
dot11bg(3),
dot11a-only(4),
dot11g-wifi(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to set the wireless NIC Operational mode.
Depending on the wireless NIC in the device different wireless
operational modes can be configured. The supported modes are:
- 802.11b only
- 802.11g only
- 802.11b/g
- 802.11a only
- 802.11g-wifi"
::= { oriWirelessIfPropertiesEntry 22 }
oriWirelessIfPreambleType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the wireless interface preamble type
based on the wireless operational mode configured."
::= { oriWirelessIfPropertiesEntry 23 }
oriWirelessIfProtectionMechanismStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates if protection mechanism is enabled or not
based on the wireless operational mode configured."
::= { oriWirelessIfPropertiesEntry 24 }
oriWirelessIfSupportedMulticastRates OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the multicast rates supported by the wireless
NIC and the operational mode configured."
::= { oriWirelessIfPropertiesEntry 25 }
oriWirelessIfCapabilities OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides information on the wireless capabilities and
features supported by the wireless NIC. Each bit in this object
defines a capability/feature supported by the wireless NIC. If the
bit is set, the capability/feature is supported, otherwise it is not.
The following list provides a definition of the bits in this object:
b0 - Distance Between APs
b1 - Multicast Rate
b2 - Closed System
b3 - Load Balancing
b4 - Medium Density Distribution
b5 - Auto Channel Select
b6 - Turbo Mode
b7 - Interference Robustness
b8 - Wireless Distribution System (WDS)
b9 - Transmit Power Control (TPC)
b10 - Multiple SSIDs
b11 - SpectraLink VoIP
b12 - Remote Link Test
b13 to b255 - Reserved"
::= { oriWirelessIfPropertiesEntry 26 }
oriWirelessIfLBTxTimeThreshold OBJECT-TYPE
SYNTAX Integer32 (100..1000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum allowed Tx processing time, in mS, where Tx processing time
is measured from time a packet enters AP from the DS to the time it
successfully leaves the AP's Radio."
DEFVAL { 1000000 }
::= { oriWirelessIfPropertiesEntry 27 }
oriWirelessIfLBAdjAPTimeDiffThreshold OBJECT-TYPE
SYNTAX Integer32 (100..1000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum allowed difference in mS between adjacent AP's Tx processing
time."
DEFVAL { 1000000 }
::= { oriWirelessIfPropertiesEntry 28 }
oriWirelessIfACSFrequencyBandScan OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the frequency bands that the auto
channel select algorithm will scan through. Each bit in this object
represents a band or subset of channels in the 5 GHz or 2.4 GHz space.
The value of this object is interpreted as a bitfield, where the
value of 1 means enable ACS scan for that band.
The following list provides a definition of the bits in this object:
b0 - U-NII Lower Band = 5.15 - 5.25 GHz (36, 40, 44, 48)
b1 - U-NII Middle Band = 5.25 - 5.35 GHz (52, 56, 60, 64)
b2 - U-NII Upper Band = 5.725 - 5.825 GHz (149, 153, 157, 161)
b3 - H Band = 5.50 - 5.700 GHz (100, 104, 108, 112, 116, 120,
124, 128, 132, 136, 140)
b4 - 5 GHz ISM Band = 5.825 GHz (165)
b5 to b255 - Reserved"
DEFVAL { 3 }
::= { oriWirelessIfPropertiesEntry 29 }
oriWirelessIfSecurityPerSSIDStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the security per SSID
feature. Once this object is enabled, the administrator should use
the Wireless Interface SSID table (oriWirelessIfSSIDTable to
configure the security related management objects."
DEFVAL { disable }
::= { oriWirelessIfPropertiesEntry 30 }
oriWirelessIfDFSStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable/disable dynamic frequency selection.
This functionality is dependent on the regulatory domain of the
wireless NIC."
DEFVAL { disable }
::= { oriWirelessIfPropertiesEntry 31 }
oriWirelessIfAntenna OBJECT-TYPE
SYNTAX INTEGER
{
external(1),
internal(2),
controllable(3),
disabled(4)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object is used to configure the antenna. The administrator can
select controllable, external, internal, or disable the antenna."
DEFVAL { external }
::= { oriWirelessIfPropertiesEntry 32 }
oriWirelessIfTPCMode OBJECT-TYPE
SYNTAX Integer32 (0 | 3 | 6 | 9 | 12 | 15 | 18)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the transmit power control of
the wireless NIC. The transmit power is defined in dBm and can be
configured in increments 3 dBms."
DEFVAL { 0 }
::= { oriWirelessIfPropertiesEntry 33 }
oriWirelessIfSuperModeStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable/disable super mode support. Super Mode
increases the overall throughput of the wireless interface by
implementing fast frame, bursting, and compression. When super mode
is enabled, the channels that can be used in the 2.4 GHz and 5.0 GHz
spectrum are limited (refer to oriWirelessIfAllowedChannels for the
allowed channels). The super mode feature is only supported for
802.11a (OFDM - 5 GHz) and 802.11g (ERP - 2.4 GHz) wireless NICs."
DEFVAL { disable }
::= { oriWirelessIfPropertiesEntry 34 }
oriWirelessIfWSSStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for the Wireless System Shutdown feature. This
feature allows an administrator to shut down wireless services to
clients. When this object is set to down wireless client services
will be shutdown/disabled, but WDS links will still remain up."
DEFVAL { up }
::= { oriWirelessIfPropertiesEntry 35 }
oriWirelessIfSupportedAuthenticationModes OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to provide information on the authentication modes
supported by the wireless interface. The possible authentication modes
are:
- none: no authentication mode
- dot1x: 802.1x authentication mode
- psk: psk authentication mode"
::= { oriWirelessIfPropertiesEntry 36 }
oriWirelessIfSupportedCipherModes OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to provide information on the cipher modes/types
supported by the wireless interface. The possible cipher modes/types
are:
- none: no cipher/encryption mode
- wep: wep encryption mode
- tkip: tkip encryption mode
- aes: aes encryption mode"
::= { oriWirelessIfPropertiesEntry 37 }
oriWirelessIfQoSStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable/disable Quality of Service (QoS) on the
wireless interface."
DEFVAL { disable }
::= { oriWirelessIfPropertiesEntry 38 }
oriWirelessIfQoSMaxMediumThreshold OBJECT-TYPE
SYNTAX Integer32 (50..90)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to specify the QoS admission control maximum
medium threshold. The maximum medium threshold will apply to all
access categories and is given in a percentage of the medium."
::= { oriWirelessIfPropertiesEntry 39 }
oriWirelessIfAntennaGain OBJECT-TYPE
SYNTAX Integer32 (0..35)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents Antenna Gain value (including cable loss) that will be
added to the radar detetection parameters."
DEFVAL { 0 }
::= { oriWirelessIfPropertiesEntry 40 }
--=============================================================================
-- The Wireless Interface Security Table: oriWirelessIfSecurityTable
--=============================================================================
oriWirelessIfSecurityTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriWirelessIfSecurityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains information on the security management objects
for the wireless interface(s) present in the device."
::= { orinocoWirelessIf 2 }
oriWirelessIfSecurityEntry OBJECT-TYPE
SYNTAX OriWirelessIfSecurityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the wireless interface
security table."
INDEX { oriWirelessIfSecurityIndex }
::= { oriWirelessIfSecurityTable 1 }
OriWirelessIfSecurityEntry ::=
SEQUENCE
{
oriWirelessIfSecurityIndex Integer32,
oriWirelessIfEncryptionOptions INTEGER,
oriWirelessIfEncryptionStatus INTEGER,
oriWirelessIfEncryptionKey1 DisplayString,
oriWirelessIfEncryptionKey2 DisplayString,
oriWirelessIfEncryptionKey3 DisplayString,
oriWirelessIfEncryptionKey4 DisplayString,
oriWirelessIfEncryptionTxKey Integer32,
oriWirelessIfDenyNonEncryptedData INTEGER,
oriWirelessIfProfileCode Integer32
}
oriWirelessIfSecurityIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents a unique value for each interface in the
system and is used as index to this table."
::= { oriWirelessIfSecurityEntry 1 }
oriWirelessIfEncryptionOptions OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
wep(2),
rcFour128(3),
aes(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object sets the wireless interface's security
capabilities (such as WEP and other standard and proprietary
security features).
AES encryption is only for 802.11a and supports only OCB mode
integrity check."
::= { oriWirelessIfSecurityEntry 2 }
oriWirelessIfEncryptionStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object is used to enable or disable WEP encryption for the
wireless interface."
DEFVAL { disable }
::= { oriWirelessIfSecurityEntry 3 }
oriWirelessIfEncryptionKey1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents Encryption Key 1. This object should be
treated as write-only and returned as asterisks."
::= { oriWirelessIfSecurityEntry 4 }
oriWirelessIfEncryptionKey2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents Encryption Key 2. This object should be
treated as write-only and returned as asterisks."
::= { oriWirelessIfSecurityEntry 5 }
oriWirelessIfEncryptionKey3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents Encryption Key 3. This object should be
treated as write-only and returned as asterisks."
::= { oriWirelessIfSecurityEntry 6 }
oriWirelessIfEncryptionKey4 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents Encryption Key 4. This object should be
treated as write-only and returned as asterisks."
::= { oriWirelessIfSecurityEntry 7 }
oriWirelessIfEncryptionTxKey OBJECT-TYPE
SYNTAX Integer32 (0..3)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates which encryption key is used to encrypt
data that is sent via the wireless interfaces. When this object is
configured to 0, then Encryption Key 1 will be used. When this object
is configured to 1, then Encryption Key 2 will be used. When
this object is configured to 2, then Encryption Key 3 will be used.
When this object is configured to 3, then Encryption Key 4 will be
used. The default value for this object should be key 0."
DEFVAL { 0 }
::= { oriWirelessIfSecurityEntry 8 }
oriWirelessIfDenyNonEncryptedData OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates if this interface will accept or deny
non-encrypted data. The default value for this parameters is
disabled."
DEFVAL { disable }
::= { oriWirelessIfSecurityEntry 9 }
oriWirelessIfProfileCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object represents the profile code of the wirelesss interface.
This information is comprised of a vendor indication and a
capability indication (example: bronze or gold card)."
::= { oriWirelessIfSecurityEntry 10 }
--=============================================================================
-- The Wireless Interface SSID Table: oriWirelessIfSSIDTable
--=============================================================================
oriWirelessIfSSIDTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriWirelessIfSSIDTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to configure the SSIDs for the wireless interface
in the device."
::= { orinocoWirelessIf 3 }
oriWirelessIfSSIDTableEntry OBJECT-TYPE
SYNTAX OriWirelessIfSSIDTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the respective table.
In this case each table entry represents a VLAN ID."
INDEX { ifIndex, oriWirelessIfSSIDTableIndex }
::= { oriWirelessIfSSIDTable 1 }
OriWirelessIfSSIDTableEntry ::=
SEQUENCE
{
oriWirelessIfSSIDTableIndex Integer32,
oriWirelessIfSSIDTableSSID DisplayString,
oriWirelessIfSSIDTableVLANID VlanId,
oriWirelessIfSSIDTableStatus RowStatus,
oriWirelessIfSSIDTableSecurityMode INTEGER,
oriWirelessIfSSIDTableBroadcastSSID ObjStatus,
oriWirelessIfSSIDTableClosedSystem ObjStatus,
oriWirelessIfSSIDTableSupportedSecurityModes DisplayString,
oriWirelessIfSSIDTableEncryptionKey0 WEPKeyType,
oriWirelessIfSSIDTableEncryptionKey1 WEPKeyType,
oriWirelessIfSSIDTableEncryptionKey2 WEPKeyType,
oriWirelessIfSSIDTableEncryptionKey3 WEPKeyType,
oriWirelessIfSSIDTableEncryptionTxKey Integer32,
oriWirelessIfSSIDTableEncryptionKeyLength INTEGER,
oriWirelessIfSSIDTableRekeyingInterval Integer32,
oriWirelessIfSSIDTablePSKValue OCTET STRING,
oriWirelessIfSSIDTablePSKPassPhrase DisplayString,
oriWirelessIfSSIDTableDenyNonEncryptedData ObjStatus,
oriWirelessIfSSIDTableSSIDAuthorizationStatus ObjStatus,
oriWirelessIfSSIDTableMACAccessControl ObjStatus,
oriWirelessIfSSIDTableRADIUSMACAccessControl ObjStatus,
oriWirelessIfSSIDTableSecurityProfile Integer32,
oriWirelessIfSSIDTableRADIUSDot1xProfile DisplayString,
oriWirelessIfSSIDTableRADIUSMACAuthProfile DisplayString,
oriWirelessIfSSIDTableRADIUSAccountingStatus ObjStatus,
oriWirelessIfSSIDTableRADIUSAccountingProfile DisplayString,
oriWirelessIfSSIDTableQoSPolicy Integer32
}
oriWirelessIfSSIDTableIndex OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the index to the SSID Table."
::= { oriWirelessIfSSIDTableEntry 1 }
oriWirelessIfSSIDTableSSID OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the wireless card SSID string (wireless network
name)."
::= { oriWirelessIfSSIDTableEntry 2 }
oriWirelessIfSSIDTableVLANID OBJECT-TYPE
SYNTAX VlanId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the VLAN Identifier (ID)."
DEFVAL { -1 }
::= { oriWirelessIfSSIDTableEntry 3 }
oriWirelessIfSSIDTableStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the wireless SSID table row/entry status."
::= { oriWirelessIfSSIDTableEntry 4 }
oriWirelessIfSSIDTableSecurityMode OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
dot1x(2),
mixed(3),
wpa(4),
wpa-psk(5),
wep(6)
}
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"This object is used to configure the security mode for this table
entry (SSID). This object is deprecated."
DEFVAL { none }
::= { oriWirelessIfSSIDTableEntry 5 }
oriWirelessIfSSIDTableBroadcastSSID OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to enable/disable a broadcast SSID in the SSID
table. A single entry in the SSID table can be enabled to broadcast
SSID in beacon messages."
DEFVAL { disable }
::= { oriWirelessIfSSIDTableEntry 6 }
oriWirelessIfSSIDTableClosedSystem OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to enable/disable the closed system feature
for this table entry (SSID)."
DEFVAL { enable }
::= { oriWirelessIfSSIDTableEntry 7 }
oriWirelessIfSSIDTableSupportedSecurityModes OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "This object is used to provide information on the supported
security modes by the wireless interface(s). The possible security
modes can be:
- None: no security mode enabled.
- dot1x: 802.1x authentication enabled.
- mixed: mixed WEP and 802.1x.
- wpa: WiFi Protected Access enabled.
- wpa-psk: WiFi Protected Access with Preshared Keys enabled.
- wep: WEP Encryption enabled (no authentication)
This object is deprecated."
::= { oriWirelessIfSSIDTableEntry 8 }
oriWirelessIfSSIDTableEncryptionKey0 OBJECT-TYPE
SYNTAX WEPKeyType
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"This object represents Encryption Key 0. This object should be
treated as write-only and returned as asterisks. This object is
deprecated."
::= { oriWirelessIfSSIDTableEntry 9 }
oriWirelessIfSSIDTableEncryptionKey1 OBJECT-TYPE
SYNTAX WEPKeyType
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"This object represents Encryption Key 1. This object should be
treated as write-only and returned as asterisks. This object is
deprecated."
::= { oriWirelessIfSSIDTableEntry 10 }
oriWirelessIfSSIDTableEncryptionKey2 OBJECT-TYPE
SYNTAX WEPKeyType
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"This object represents Encryption Key 2. This object should be
treated as write-only and returned as asterisks. This object is
deprecated."
::= { oriWirelessIfSSIDTableEntry 11 }
oriWirelessIfSSIDTableEncryptionKey3 OBJECT-TYPE
SYNTAX WEPKeyType
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"This object represents Encryption Key 3. This object should be
treated as write-only and returned as asterisks. This object is
deprecated."
::= { oriWirelessIfSSIDTableEntry 12 }
oriWirelessIfSSIDTableEncryptionTxKey OBJECT-TYPE
SYNTAX Integer32 (0..3)
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"This object indicates which encryption key is used to encrypt
data that is sent via the wireless interfaces. The default value
for this object should be key 0. This object is deprecated."
DEFVAL { 0 }
::= { oriWirelessIfSSIDTableEntry 13 }
oriWirelessIfSSIDTableEncryptionKeyLength OBJECT-TYPE
SYNTAX INTEGER
{
sixtyFourBits(1),
oneHundredTwentyEightBits(2),
oneHundredFiftyTwoBits(3)
}
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"This object represents the encryption key length, the supported
key lengths are 64 bits (40 + 24 for IV), 128 bits
(104 + 24 for IV), and 152 bits (128 + 24 for IV). This object is
deprecated."
DEFVAL { sixtyFourBits }
::= { oriWirelessIfSSIDTableEntry 14 }
oriWirelessIfSSIDTableRekeyingInterval OBJECT-TYPE
SYNTAX Integer32 (0 | 300..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the encryption rekeying interval. if this
object is configured to zero (0) rekeying is disabled. The units
of this object is seconds."
DEFVAL { 900 }
::= { oriWirelessIfSSIDTableEntry 15 }
oriWirelessIfSSIDTablePSKValue OBJECT-TYPE
SYNTAX OCTET STRING ( SIZE (32) )
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"The Pre-Shared Key (PSK) for when RSN in PSK mode is the selected
authentication suite. In that case, the PMK will obtain its value
from this object.
This object is logically write-only. Reading this variable shall
return unsuccessful status or null or zero. This object is deprecated."
::= { oriWirelessIfSSIDTableEntry 16 }
oriWirelessIfSSIDTablePSKPassPhrase OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"The PSK, for when RSN in PSK mode is the selected authentication
suite, is configured by oriWirelessIfSSIDTablePSKValue. An alternative
manner of setting the PSK uses the password-to-key algorithm defined
in the standard. This variable provides a means to enter a pass phrase.
When this object is written, the RSN entity shall use the
password-to-key algorithm specified in the standard to derive a
pre-shared and populate oriWirelessIfSSIDTablePSKValue with this key.
This object is logically write-only. Reading this variable shall
return unsuccessful status or null or zero. This object is deprecated."
::= { oriWirelessIfSSIDTableEntry 17 }
oriWirelessIfSSIDTableDenyNonEncryptedData OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"This object is used to enable/disable deny non encrypted data. This
function is only supported when the security mode is configured to
WEP or Mixed Mode; it is not supported for 802.1x, WPA, and WPA-PSK
security modes. This object is deprecated."
DEFVAL { enable }
::= { oriWirelessIfSSIDTableEntry 18 }
oriWirelessIfSSIDTableSSIDAuthorizationStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable SSID Authorization."
DEFVAL { disable }
::= { oriWirelessIfSSIDTableEntry 19}
oriWirelessIfSSIDTableMACAccessControl OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable MAC Access Control
feature/filter for this SSID."
DEFVAL { disable }
::= { oriWirelessIfSSIDTableEntry 20 }
oriWirelessIfSSIDTableRADIUSMACAccessControl OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enables RADIUS Access Control based on
wireless stations MAC Address."
DEFVAL { disable }
::= { oriWirelessIfSSIDTableEntry 21 }
oriWirelessIfSSIDTableSecurityProfile OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to configure the security profile that will be
used for this SSID. The security profile is defined in the Security
Profile Table in the orinocoSecurity group."
::= { oriWirelessIfSSIDTableEntry 22 }
oriWirelessIfSSIDTableRADIUSDot1xProfile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to configure the RADIUS server profile that will be
used for 802.1x authentication for this SSID. The RADIUS profile is
defined in the RADIUS Server Table in the orinocoRADIUSSvrProfile
group."
::= { oriWirelessIfSSIDTableEntry 23 }
oriWirelessIfSSIDTableRADIUSMACAuthProfile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to configure the RADIUS server profile that will be
used for MAC based RADIUS authentication for this SSID. The RADIUS
profile is defined in the RADIUS Server Table in the
orinocoRADIUSSvrProfile group."
::= { oriWirelessIfSSIDTableEntry 24 }
oriWirelessIfSSIDTableRADIUSAccountingStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the RADIUS Accounting
service per SSID."
DEFVAL { disable }
::= { oriWirelessIfSSIDTableEntry 25 }
oriWirelessIfSSIDTableRADIUSAccountingProfile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to configure the RADIUS server profile that will
be used for Accounting for this SSID. The RADIUS profile is defined
in the RADIUS Server Table in the orinocoRADIUSSvrProfile group."
::= { oriWirelessIfSSIDTableEntry 26 }
oriWirelessIfSSIDTableQoSPolicy OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to configure the QoS policy that will be
used for this SSID. The QoS profile is defined in the QoS Policy
Table in the orinocoQoS group."
::= { oriWirelessIfSSIDTableEntry 27 }
--=============================================================================
-- The Wireless Interface Group Scalar Objects
--=============================================================================
oriWirelessIfTxPowerControl OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable Transmit (Tx) Power Control
feature."
DEFVAL { disable }
::= { orinocoWirelessIf 4 }
--=============================================================================
-- The Ethernet Interface Subgroup: orinocoEthernetIf
--=============================================================================
oriEthernetIfConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriEthernetIfConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to configure the ethernet interface(s) for the
device."
::= { orinocoEthernetIf 1 }
oriEthernetIfConfigTableEntry OBJECT-TYPE
SYNTAX OriEthernetIfConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the ethernet interface
configuration table."
INDEX { oriEthernetIfConfigTableIndex }
::= { oriEthernetIfConfigTable 1 }
OriEthernetIfConfigTableEntry ::=
SEQUENCE
{
oriEthernetIfConfigTableIndex Integer32,
oriEthernetIfConfigSettings INTEGER,
oriEthernetIfConfigBandwidthLimitIn Gauge32,
oriEthernetIfConfigBandwidthLimitOut Gauge32
}
oriEthernetIfConfigTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the index of the ethernet configuraiton
table."
::= { oriEthernetIfConfigTableEntry 1 }
oriEthernetIfConfigSettings OBJECT-TYPE
SYNTAX INTEGER
{
tenMegabitPerSecHalfDuplex(1),
tenMegabitPerSecFullDuplex(2),
tenMegabitPerSecAutoDuplex(3),
onehundredMegabitPerSecHalfDuplex(4),
onehundredMegabitPerSecFullDuplex(5),
autoSpeedHalfDuplex(6),
autoSpeedAutoDuplex(7),
onehundredMegabitPerSecAutoDuplex(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the Ethernet interface's speed.
Some devices support all the configuration options
listed above, while others support only a subset of the
configuration options."
::= { oriEthernetIfConfigTableEntry 2 }
oriEthernetIfConfigBandwidthLimitIn OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the input bandwidth limit of the interface
in increments of 64 kbps. The value can be limited by a previous
written value, the negotiation process during registration, or by
a license. A written value will only take effect after reboot."
::= { oriEthernetIfConfigTableEntry 3 }
oriEthernetIfConfigBandwidthLimitOut OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the output bandwidth limit of the interface
in increments of 64 kbps. The value can be limited by a previous
written value, the negotiation process during registration, or by
a license. A written value will only take effect after reboot."
::= { oriEthernetIfConfigTableEntry 4 }
--=============================================================================
-- The Interface Subgroup: orinocoIf
--=============================================================================
oriIfWANInterfaceMACAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the MAC address of the WAN interface."
::= { orinocoIf 4 }
--=============================================================================
-- The WORP Interface Subgroup: orinocoWORPIf
--=============================================================================
oriWORPIfConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriWORPIfConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to configure the mode, time-outs, and protocol
objects for wireless interface(s) that are configured to run WORP."
::= { orinocoWORPIf 1 }
oriWORPIfConfigTableEntry OBJECT-TYPE
SYNTAX OriWORPIfConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the WORP Interface
Configuration Table."
INDEX { ifIndex }
::= { oriWORPIfConfigTable 1 }
OriWORPIfConfigTableEntry ::=
SEQUENCE
{
oriWORPIfConfigTableMode INTEGER,
oriWORPIfConfigTableBaseStationName DisplayString,
oriWORPIfConfigTableMaxSatellites Integer32,
oriWORPIfConfigTableRegistrationTimeout Integer32,
oriWORPIfConfigTableRetries Integer32,
oriWORPIfConfigTableNetworkSecret DisplayString,
oriWORPIfConfigTableNoSleepMode ObjStatus
}
oriWORPIfConfigTableMode OBJECT-TYPE
SYNTAX INTEGER
{
disabled(1),
ap(2),
base(3),
satellite(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The running mode of this interface:
- If set to disabled, the interface is disabled.
- If set to AP, the interface will run in standard IEEE802.11
mode.
- If set to Base, the interface will be a WORP master
interface and be able to connect to multiple WORP satellites.
- If set to Satellite, the interface will be a WORP slave
interface."
DEFVAL { disabled }
::= { oriWORPIfConfigTableEntry 1 }
oriWORPIfConfigTableBaseStationName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the base station. For a base this name will default
to the MIB-II sysName; for a satellite to empty (if not registered
to any base) or the name it is registered to. When a name is set
for a satellite, the satellite will only register on a base
with this name."
::= { oriWORPIfConfigTableEntry 2 }
oriWORPIfConfigTableMaxSatellites OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum of remotes allowed on this interface. Please note
that this value will also be limited by the image and the
license."
::= { oriWORPIfConfigTableEntry 3 }
oriWORPIfConfigTableRegistrationTimeout OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the Timeout of regristration and
authentication, configurable between 1sec and 10sec."
::= { oriWORPIfConfigTableEntry 4 }
oriWORPIfConfigTableRetries OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of times a data message will be retransmitted,
configurable between 0 and 10. The value 0 allows unreliable
operation for streaming applications."
::= { oriWORPIfConfigTableEntry 5 }
oriWORPIfConfigTableNetworkSecret OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The NetworkSecret is a string that must be the same for all
stations in a certain network. If a station has another secret
configured as the base, the base will not allow the station to
register. This object should be treated as write-only and
returned as asterisks."
::= { oriWORPIfConfigTableEntry 6 }
oriWORPIfConfigTableNoSleepMode OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable sleep mode. If this object
is enabled, a subscriber unit will not go into sleep mode when
they have no data to send."
DEFVAL { disable }
::= { oriWORPIfConfigTableEntry 7 }
oriWORPIfStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriWORPIfStatTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to monitor the statistics of interfaces that
run WORP."
::= { orinocoWORPIf 2 }
oriWORPIfStatTableEntry OBJECT-TYPE
SYNTAX OriWORPIfStatTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the WORP Interface
Statistics Table."
INDEX { ifIndex }
::= { oriWORPIfStatTable 1 }
OriWORPIfStatTableEntry ::=
SEQUENCE
{
oriWORPIfStatTableRemotePartners Counter32,
oriWORPIfStatTableAverageLocalSignal Integer32,
oriWORPIfStatTableAverageLocalNoise Integer32,
oriWORPIfStatTableAverageRemoteSignal Integer32,
oriWORPIfStatTableAverageRemoteNoise Integer32,
oriWORPIfStatTableBaseStationAnnounces Counter32,
oriWORPIfStatTableRegistrationRequests Counter32,
oriWORPIfStatTableRegistrationRejects Counter32,
oriWORPIfStatTableAuthenticationRequests Counter32,
oriWORPIfStatTableAuthenticationConfirms Counter32,
oriWORPIfStatTableRegistrationAttempts Counter32,
oriWORPIfStatTableRegistrationIncompletes Counter32,
oriWORPIfStatTableRegistrationTimeouts Counter32,
oriWORPIfStatTableRegistrationLastReason INTEGER,
oriWORPIfStatTablePollData Counter32,
oriWORPIfStatTablePollNoData Counter32,
oriWORPIfStatTableReplyData Counter32,
oriWORPIfStatTableReplyMoreData Counter32,
oriWORPIfStatTableReplyNoData Counter32,
oriWORPIfStatTableRequestForService Counter32,
oriWORPIfStatTableSendSuccess Counter32,
oriWORPIfStatTableSendRetries Counter32,
oriWORPIfStatTableSendFailures Counter32,
oriWORPIfStatTableReceiveSuccess Counter32,
oriWORPIfStatTableReceiveRetries Counter32,
oriWORPIfStatTableReceiveFailures Counter32,
oriWORPIfStatTablePollNoReplies Counter32
}
oriWORPIfStatTableRemotePartners OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of remote partners. For a satellite, this parameter
will always be zero or one."
::= { oriWORPIfStatTableEntry 1 }
oriWORPIfStatTableAverageLocalSignal OBJECT-TYPE
SYNTAX Integer32 (-102..-10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current signal level calculated over all inbound packets.
This variable indicates the running average of the local signal
level using the algorithm (3/4*oldvalue + 1/4*newvalue)."
::= { oriWORPIfStatTableEntry 2 }
oriWORPIfStatTableAverageLocalNoise OBJECT-TYPE
SYNTAX Integer32 (-102..-10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current noise level calculated over all inbound packets.
This variable indicates the running average of the local noise
level using the algorithm (3/4*oldvalue + 1/4*newvalue)."
::= { oriWORPIfStatTableEntry 3 }
oriWORPIfStatTableAverageRemoteSignal OBJECT-TYPE
SYNTAX Integer32 (-102..-10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current remote signal level calculated over the inbound
packets send by this station. This variable indicates the
running average over all registered stations of the remote
signal level using the algorithm (3/4*oldvalue + 1/4*newvalue)."
::= { oriWORPIfStatTableEntry 4 }
oriWORPIfStatTableAverageRemoteNoise OBJECT-TYPE
SYNTAX Integer32 (-102..-10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current average remote noise level calculated over the
inbound packets send by this station. This variable indicates
the running average over all registered stations of the remote
noise level using the algorithm (3/4*oldvalue + 1/4*newvalue)."
::= { oriWORPIfStatTableEntry 5 }
oriWORPIfStatTableBaseStationAnnounces OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Base Station Announces Broadcasts (BSAB) sent
(base) or received (satellite) on this interface."
::= { oriWORPIfStatTableEntry 6 }
oriWORPIfStatTableRegistrationRequests OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Registration Requests (RREQ) sent (satellite) or
received (base) on this interface."
::= { oriWORPIfStatTableEntry 7 }
oriWORPIfStatTableRegistrationRejects OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Registration Rejects (RREJ) sent (base) or
received (satellite) on this interface."
::= { oriWORPIfStatTableEntry 8 }
oriWORPIfStatTableAuthenticationRequests OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Authentication Requests (AREQ) sent (satellite) or
received (base) on this interface."
::= { oriWORPIfStatTableEntry 9 }
oriWORPIfStatTableAuthenticationConfirms OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Authentication Confirms (ACFM) sent (base) or
received (satellite) on this interface."
::= { oriWORPIfStatTableEntry 10 }
oriWORPIfStatTableRegistrationAttempts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times a Registration Attempt has been initiated."
::= { oriWORPIfStatTableEntry 11 }
oriWORPIfStatTableRegistrationIncompletes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of registration attempts that is not completed yet.
For a satellite this parameters will always be zero or one."
::= { oriWORPIfStatTableEntry 12 }
oriWORPIfStatTableRegistrationTimeouts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the registration procedure timed out."
::= { oriWORPIfStatTableEntry 13 }
oriWORPIfStatTableRegistrationLastReason OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
noMoreAllowed(2),
incorrectParameter(3),
roaming(4),
timeout(5),
lowQuality(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The reason for why the last registration was aborted or failed."
::= { oriWORPIfStatTableEntry 14 }
oriWORPIfStatTablePollData OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of polls with data sent (base) or received
(satellite)."
::= { oriWORPIfStatTableEntry 15 }
oriWORPIfStatTablePollNoData OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of polls with no data sent (base) or received
(satellite)."
::= { oriWORPIfStatTableEntry 16 }
oriWORPIfStatTableReplyData OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of poll replies with data sent (satellite) or
received (base). This counter does not include replies with the
MoreData flag set (see ReplyMoreData)."
::= { oriWORPIfStatTableEntry 17 }
oriWORPIfStatTableReplyMoreData OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of poll replies with data sent (satellite) or
received (base) with the MoreData flag set (see also ReplyData)."
::= { oriWORPIfStatTableEntry 18 }
oriWORPIfStatTableReplyNoData OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of poll replies with no data sent (satellite) or
received (base)."
::= { oriWORPIfStatTableEntry 19 }
oriWORPIfStatTableRequestForService OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of requests for service sent (satellite) or
received (base)."
::= { oriWORPIfStatTableEntry 20 }
oriWORPIfStatTableSendSuccess OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data packets sent that were acknowledged and did
not need a retransmit."
::= { oriWORPIfStatTableEntry 21 }
oriWORPIfStatTableSendRetries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data packets sent that needed retransmition but
were finally received succesfully by the remote partner."
::= { oriWORPIfStatTableEntry 22 }
oriWORPIfStatTableSendFailures OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data packets sent that were (finally) not received
succesfully by the remote partner."
::= { oriWORPIfStatTableEntry 23 }
oriWORPIfStatTableReceiveSuccess OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data packets received that were acknowledged and
did not need a retransmit of the remote partner."
::= { oriWORPIfStatTableEntry 24 }
oriWORPIfStatTableReceiveRetries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data packets received that needed retransmition by
the remote partner but were finally received succesfully."
::= { oriWORPIfStatTableEntry 25 }
oriWORPIfStatTableReceiveFailures OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data packets that were (finally) not received
succesfully."
::= { oriWORPIfStatTableEntry 26 }
oriWORPIfStatTablePollNoReplies OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times a poll was sent but no reply was received.
This object only applies to the base."
::= { oriWORPIfStatTableEntry 27 }
--=============================================================================
-- Definition of the WORP Satellite Subgroups
-- orinocoWORPIfSatConfig
-- orinocoWORPIfSatStat
--=============================================================================
oriWORPIfSatConfigStatus OBJECT-TYPE
SYNTAX INTEGER
{
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the per-satellite config
from the base device."
DEFVAL { disabled }
::= { orinocoWORPIfSatConfig 1 }
oriWORPIfSatConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriWORPIfSatConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains wireless stations statistics."
::= { orinocoWORPIfSatConfig 2 }
oriWORPIfSatConfigTableEntry OBJECT-TYPE
SYNTAX OriWORPIfSatConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the WORP Interface
Satellite Statistics Table."
INDEX { oriWORPIfSatConfigTableIndex }
::= { oriWORPIfSatConfigTable 1 }
OriWORPIfSatConfigTableEntry ::=
SEQUENCE
{
oriWORPIfSatConfigTableIndex Integer32,
oriWORPIfSatConfigTableEntryStatus INTEGER,
oriWORPIfSatConfigTableMacAddress MacAddress,
oriWORPIfSatConfigTableMinimumBandwidthLimitDownlink Gauge32,
oriWORPIfSatConfigTableMaximumBandwidthLimitDownlink Gauge32,
oriWORPIfSatConfigTableMinimumBandwidthLimitUplink Gauge32,
oriWORPIfSatConfigTableMaximumBandwidthLimitUplink Gauge32,
oriWORPIfSatConfigTableComment DisplayString
}
oriWORPIfSatConfigTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to index the protocol filter table."
::= { oriWORPIfSatConfigTableEntry 1 }
oriWORPIfSatConfigTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable, disable, delete, create the
Ethernet protocols in this table."
::= { oriWORPIfSatConfigTableEntry 2 }
oriWORPIfSatConfigTableMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object represents the MAC address of the satellite
for which the statistics are gathered."
::= { oriWORPIfSatConfigTableEntry 3 }
oriWORPIfSatConfigTableMinimumBandwidthLimitDownlink OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the minimum input bandwidth limit of the
interface in increments of 64 kbps. The value can be limited by a
previous written value, the negotiation process during registration or
by a license. A written value will only take effect after reboot."
::= { oriWORPIfSatConfigTableEntry 4 }
oriWORPIfSatConfigTableMaximumBandwidthLimitDownlink OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the maximum input bandwidth limit of the
interface in increments of 64 kbps. The value can be limited by a
previous written value, the negotiation process during registration
or by a license. A written value will only take effect after reboot."
::= { oriWORPIfSatConfigTableEntry 5 }
oriWORPIfSatConfigTableMinimumBandwidthLimitUplink OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the minimum output bandwidth limit of the
interface in increments of 64 kbps. The value can be limited by a
previous written value, the negotiation process during registration or
by a license. A written value will only take effect after reboot."
::= { oriWORPIfSatConfigTableEntry 6 }
oriWORPIfSatConfigTableMaximumBandwidthLimitUplink OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the maximum output bandwidth limit of the
interface in increments of 64 kbps. The value can be limited by a
previous written value, the negotiation process during registration or
by a license. A written value will only take effect after reboot."
::= { oriWORPIfSatConfigTableEntry 7 }
oriWORPIfSatConfigTableComment OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for an optional comment associated to the
per Satellite config Table entry."
::= { oriWORPIfSatConfigTableEntry 8 }
oriWORPIfSatStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriWORPIfSatStatTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains wireless stations statistics."
::= { orinocoWORPIfSatStat 1 }
oriWORPIfSatStatTableEntry OBJECT-TYPE
SYNTAX OriWORPIfSatStatTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the WORP Interface
Satellite Statistics Table."
INDEX { oriStationStatTableIndex }
::= { oriWORPIfSatStatTable 1 }
OriWORPIfSatStatTableEntry ::=
SEQUENCE
{
oriWORPIfSatStatTableIndex Integer32,
oriWORPIfSatStatTableMacAddress MacAddress,
oriWORPIfSatStatTableAverageLocalSignal Integer32,
oriWORPIfSatStatTableAverageLocalNoise Integer32,
oriWORPIfSatStatTableAverageRemoteSignal Integer32,
oriWORPIfSatStatTableAverageRemoteNoise Integer32,
oriWORPIfSatStatTablePollData Counter32,
oriWORPIfSatStatTablePollNoData Counter32,
oriWORPIfSatStatTableReplyData Counter32,
oriWORPIfSatStatTableReplyNoData Counter32,
oriWORPIfSatStatTableRequestForService Counter32,
oriWORPIfSatStatTableSendSuccess Counter32,
oriWORPIfSatStatTableSendRetries Counter32,
oriWORPIfSatStatTableSendFailures Counter32,
oriWORPIfSatStatTableReceiveSuccess Counter32,
oriWORPIfSatStatTableReceiveRetries Counter32,
oriWORPIfSatStatTableReceiveFailures Counter32,
oriWORPIfSatStatTablePollNoReplies Counter32,
oriWORPIfSatStatTableLocalTxRate Integer32,
oriWORPIfSatStatTableRemoteTxRate Integer32
}
oriWORPIfSatStatTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the table index for SatStat Table."
::= { oriWORPIfSatStatTableEntry 1 }
oriWORPIfSatStatTableMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object represents the MAC address of the satellite
for which the statistics are gathered."
::= { oriWORPIfSatStatTableEntry 2 }
oriWORPIfSatStatTableAverageLocalSignal OBJECT-TYPE
SYNTAX Integer32 (-102..-10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current signal level calculated over all inbound packets.
This variable indicates the running average of the local signal
level using the algorithm (3/4*oldvalue + 1/4*newvalue)."
::= { oriWORPIfSatStatTableEntry 3 }
oriWORPIfSatStatTableAverageLocalNoise OBJECT-TYPE
SYNTAX Integer32 (-102..-10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current noise level calculated over all inbound packets.
This variable indicates the running average of the local noise
level using the algorithm (3/4*oldvalue + 1/4*newvalue)."
::= { oriWORPIfSatStatTableEntry 4 }
oriWORPIfSatStatTableAverageRemoteSignal OBJECT-TYPE
SYNTAX Integer32 (-102..-10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current remote signal level calculated over the inbound
packets send by this station. This variable indicates the
running average over all registered stations of the remote
signal level using the algorithm (3/4*oldvalue + 1/4*newvalue)."
::= { oriWORPIfSatStatTableEntry 5 }
oriWORPIfSatStatTableAverageRemoteNoise OBJECT-TYPE
SYNTAX Integer32 (-102..-10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current average remote noise level calculated over the
inbound packets send by this station. This variable indicates
the running average over all registered stations of the remote
noise level using the algorithm (3/4*oldvalue + 1/4*newvalue)."
::= { oriWORPIfSatStatTableEntry 6 }
oriWORPIfSatStatTablePollData OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of polls with data sent (base) or received
(satellite)."
::= { oriWORPIfSatStatTableEntry 7 }
oriWORPIfSatStatTablePollNoData OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of polls with no data sent (base) or received
(satellite)."
::= { oriWORPIfSatStatTableEntry 8 }
oriWORPIfSatStatTableReplyData OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of poll replies with data sent (satellite) or
received (base). This counter does not include replies with the
MoreData flag set (see ReplyMoreData)."
::= { oriWORPIfSatStatTableEntry 9 }
oriWORPIfSatStatTableReplyNoData OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of poll replies with no data sent (satellite) or
received (base)."
::= { oriWORPIfSatStatTableEntry 10 }
oriWORPIfSatStatTableRequestForService OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of requests for service sent (satellite) or
received (base)."
::= { oriWORPIfSatStatTableEntry 11 }
oriWORPIfSatStatTableSendSuccess OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data packets sent that were acknowledged and did
not need a retransmit."
::= { oriWORPIfSatStatTableEntry 12 }
oriWORPIfSatStatTableSendRetries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data packets sent that needed retransmition but
were finally received succesfully by the remote partner."
::= { oriWORPIfSatStatTableEntry 13 }
oriWORPIfSatStatTableSendFailures OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data packets sent that were (finally) not received
succesfully by the remote partner."
::= { oriWORPIfSatStatTableEntry 14 }
oriWORPIfSatStatTableReceiveSuccess OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data packets received that were acknowledged and
did not need a retransmit of the remote partner."
::= { oriWORPIfSatStatTableEntry 15 }
oriWORPIfSatStatTableReceiveRetries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data packets received that needed retransmition by
the remote partner but were finally received succesfully."
::= { oriWORPIfSatStatTableEntry 16 }
oriWORPIfSatStatTableReceiveFailures OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data packets that were (finally) not received
succesfully."
::= { oriWORPIfSatStatTableEntry 17 }
oriWORPIfSatStatTablePollNoReplies OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times a poll was sent but no reply was received.
This object only applies to the base."
::= { oriWORPIfSatStatTableEntry 18 }
oriWORPIfSatStatTableLocalTxRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the Transmit Data Rate of the BSU."
::= { oriWORPIfSatStatTableEntry 19 }
oriWORPIfSatStatTableRemoteTxRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the Transmit Data Rate of the SU
which is registered to this SU."
::= { oriWORPIfSatStatTableEntry 20 }
oriWORPIfSiteSurveyOperation OBJECT-TYPE
SYNTAX INTEGER
{
enabled(1),
disabled(2),
test(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the site survey mode. The site
survey is going to show user the wireless signal level, noise level and
SNR value."
DEFVAL { disabled }
::= { orinocoWORPIfSiteSurvey 1 }
oriWORPIfSiteSurveyTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriWORPIfSiteSurveySignalQualityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the information for the stations currently
associated with the access point."
::= { orinocoWORPIfSiteSurvey 2 }
oriWORPIfSiteSurveySignalQualityTableEntry OBJECT-TYPE
SYNTAX OriWORPIfSiteSurveySignalQualityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the entry in the Remote Link Test table."
INDEX { oriWORPIfSiteSurveyTableIndex }
::= { oriWORPIfSiteSurveyTable 1 }
OriWORPIfSiteSurveySignalQualityTableEntry ::=
SEQUENCE
{
oriWORPIfSiteSurveyTableIndex Integer32,
oriWORPIfSiteSurveyBaseMACAddress PhysAddress,
oriWORPIfSiteSurveyBaseName DisplayString,
oriWORPIfSiteSurveyMaxSatAllowed Integer32,
oriWORPIfSiteSurveyNumSatRegistered Integer32,
oriWORPIfSiteSurveyCurrentSatRegistered Integer32,
oriWORPIfSiteSurveyLocalSignalLevel Integer32,
oriWORPIfSiteSurveyLocalNoiseLevel Integer32,
oriWORPIfSiteSurveyLocalSNR Integer32,
oriWORPIfSiteSurveyRemoteSignalLevel Integer32,
oriWORPIfSiteSurveyRemoteNoiseLevel Integer32,
oriWORPIfSiteSurveyRemoteSNR Integer32
}
oriWORPIfSiteSurveyTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents a unique entry in the table."
::= { oriWORPIfSiteSurveySignalQualityTableEntry 1 }
oriWORPIfSiteSurveyBaseMACAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the MAC address of the base unit being tested
with."
::= { oriWORPIfSiteSurveySignalQualityTableEntry 2 }
oriWORPIfSiteSurveyBaseName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the name of the base unit being tested with.."
::= { oriWORPIfSiteSurveySignalQualityTableEntry 3 }
oriWORPIfSiteSurveyMaxSatAllowed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the maximum number of satellites is allowed to
be registered with the base unit being tested with."
::= { oriWORPIfSiteSurveySignalQualityTableEntry 4 }
oriWORPIfSiteSurveyNumSatRegistered OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the maximum number of satellites is allowed to
be registered with the base unit being tested with."
::= { oriWORPIfSiteSurveySignalQualityTableEntry 5 }
oriWORPIfSiteSurveyCurrentSatRegistered OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the maximum number of satellites is allowed to
be registered with the base unit being tested with."
::= { oriWORPIfSiteSurveySignalQualityTableEntry 6 }
oriWORPIfSiteSurveyLocalSignalLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current signal level (in dB) for the Site Survey from this
station. This object indicates the running average of the local
signal level using the algorithm (3/4*oldvalue + 1/4*newvalue)."
::= { oriWORPIfSiteSurveySignalQualityTableEntry 7 }
oriWORPIfSiteSurveyLocalNoiseLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current noise level (in dB) for the Site Survey to this station.
This object indicates the running average of the local noise
level."
::= { oriWORPIfSiteSurveySignalQualityTableEntry 8 }
oriWORPIfSiteSurveyLocalSNR OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current signal to noise ratio for the Site Survey to this
station."
::= { oriWORPIfSiteSurveySignalQualityTableEntry 9 }
oriWORPIfSiteSurveyRemoteSignalLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current signal level (in dB) for the Site Survey from the base
with which the current satellite is registered. This object indicates
the running average of the local signal level using the
algorithm (3/4*oldvalue + 1/4*newvalue)."
::= { oriWORPIfSiteSurveySignalQualityTableEntry 10 }
oriWORPIfSiteSurveyRemoteNoiseLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current noise level (in dB) for the Site Survey from the base
with which the current satellite is registered."
::= { oriWORPIfSiteSurveySignalQualityTableEntry 11 }
oriWORPIfSiteSurveyRemoteSNR OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current SNR (in dB) for the Site Survey from the base
with which the current satellite is registered."
::= { oriWORPIfSiteSurveySignalQualityTableEntry 12 }
--=============================================================================
-- The DDRS sub group under orinoco WORP group - START
--=============================================================================
oriWORPIfDDRSStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is object is used to enable/disable the WORP DDRS feature on
the BSU."
DEFVAL { disable }
::= { orinocoWORPIfDDRS 1 }
oriWORPIfDDRSDefDataRate OBJECT-TYPE
SYNTAX Integer32 (6..108)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the data rate that shall be used only when DDRS
is enabled. This is to specify default data rate on BSU.
The possible values of the variable shall be:
1. 802.11a normal mode 6Mbps
2. 802.11a normal mode 9Mbps
3. 802.11a normal mode 12Mbps
4. 802.11a normal mode 18Mbps
5. 802.11a normal mode 24Mbps
6. 802.11a normal mode 36Mbps
7. 802.11a normal mode 48Mbps
8. 802.11a normal mode 54Mbps
9. 802.11a turbo mode 12Mbps
10. 802.11a turbo mode 18Mbps
11. 802.11a turbo mode 24Mbps
12. 802.11a turbo mode 36Mbps
13. 802.11a turbo mode 48Mbps
14. 802.11a turbo mode 72Mbps
15. 802.11a turbo mode 96Mbps
16. 802.11a turbo mode 108Mbps"
::= { orinocoWORPIfDDRS 2 }
oriWORPIfDDRSMaxDataRate OBJECT-TYPE
SYNTAX Integer32 (6..108)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the data rate that shall be used only when DDRS
is enabled. This is to limit maximum possible data rate
that is set by DDRS on BSU.
The possible values of the variable shall be:
1. 802.11a normal mode 6Mbps
2. 802.11a normal mode 9Mbps
3. 802.11a normal mode 12Mbps
4. 802.11a normal mode 18Mbps
5. 802.11a normal mode 24Mbps
6. 802.11a normal mode 36Mbps
7. 802.11a normal mode 48Mbps
8. 802.11a normal mode 54Mbps
9. 802.11a turbo mode 12Mbps
10. 802.11a turbo mode 18Mbps
11. 802.11a turbo mode 24Mbps
12. 802.11a turbo mode 36Mbps
13. 802.11a turbo mode 48Mbps
14. 802.11a turbo mode 72Mbps
15. 802.11a turbo mode 96Mbps
16. 802.11a turbo mode 108Mbps"
DEFVAL { 36 }
::= { orinocoWORPIfDDRS 3 }
oriWORPIfDDRSMinReqSNRdot11an6Mbps OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to specify the minimum required SNR for data rate
of 6Mbps on 802.11a radio, normal mode. The value should be
in dB and in the range 0..50 dB. The default value should be 6dB."
DEFVAL { 6 }
::= { orinocoWORPIfDDRS 4 }
oriWORPIfDDRSMinReqSNRdot11an9Mbps OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to specify the minimum required SNR for data rate
of 9Mbps on 802.11a radio, normal mode. The value should be
in dB and in the range 0..50 dB. The default value should be 7dB."
DEFVAL { 7 }
::= { orinocoWORPIfDDRS 5 }
oriWORPIfDDRSMinReqSNRdot11an12Mbps OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to specify the minimum required SNR for data rate
of 12Mbps on 802.11a radio, normal mode. The value should be
in dB and in the range 0..50 dB. The default value should be 9dB."
DEFVAL { 9 }
::= { orinocoWORPIfDDRS 6 }
oriWORPIfDDRSMinReqSNRdot11an18Mbps OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to specify the minimum required SNR for data rate
of 18Mbps on 802.11a radio, normal mode. The value should be
in dB and in the range 0..50 dB. The default value should be 11dB."
DEFVAL { 11 }
::= { orinocoWORPIfDDRS 7 }
oriWORPIfDDRSMinReqSNRdot11an24Mbps OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to specify the minimum required SNR for data rate
of 24Mbps on 802.11a radio, normal mode. The value should be
in dB and in the range 0..50 dB. The default value should be 14dB."
DEFVAL { 14 }
::= { orinocoWORPIfDDRS 8 }
oriWORPIfDDRSMinReqSNRdot11an36Mbps OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to specify the minimum required SNR for data rate
of 36Mbps on 802.11a radio, normal mode. The value should be
in dB and in the range 0..50 dB. The default value should be 18dB."
DEFVAL { 18 }
::= { orinocoWORPIfDDRS 9 }
oriWORPIfDDRSMinReqSNRdot11an48Mbps OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to specify the minimum required SNR for data rate
of 48Mbps on 802.11a radio, normal mode. The value should be
in dB and in the range 0..50 dB. The default value should be 22dB."
DEFVAL { 22 }
::= { orinocoWORPIfDDRS 10 }
oriWORPIfDDRSMinReqSNRdot11an54Mbps OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to specify the minimum required SNR for data rate
of 54Mbps on 802.11a radio, normal mode. The value should be
in dB and in the range 0..50 dB. The default value should be 25dB."
DEFVAL { 25 }
::= { orinocoWORPIfDDRS 11 }
oriWORPIfDDRSMinReqSNRdot11at12Mbps OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to specify the minimum required SNR for data rate
of 12Mbps on 802.11a radio, turbo mode. The value should be
in dB and in the range 0..50 dB. The default value should be 6dB."
DEFVAL { 6 }
::= { orinocoWORPIfDDRS 12 }
oriWORPIfDDRSMinReqSNRdot11at18Mbps OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to specify the minimum required SNR for data rate
of 18Mbps on 802.11a radio, turbo mode. The value should be
in dB and in the range 0..50 dB. The default value should be 7dB."
DEFVAL { 7 }
::= { orinocoWORPIfDDRS 13 }
oriWORPIfDDRSMinReqSNRdot11at24Mbps OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to specify the minimum required SNR for data rate
of 24Mbps on 802.11a radio, turbo mode. The value should be
in dB and in the range 0..50 dB. The default value should be 9dB."
DEFVAL { 7 }
::= { orinocoWORPIfDDRS 14 }
oriWORPIfDDRSMinReqSNRdot11at36Mbps OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to specify the minimum required SNR for data rate
of 36Mbps on 802.11a radio, turbo mode. The value should be
in dB and in the range 0..50 dB. The default value should be 11dB."
DEFVAL { 11 }
::= { orinocoWORPIfDDRS 15 }
oriWORPIfDDRSMinReqSNRdot11at48Mbps OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to specify the minimum required SNR for data rate
of 48Mbps on 802.11a radio, turbo mode. The value should be
in dB and in the range 0..50 dB. The default value should be 14dB."
DEFVAL { 14 }
::= { orinocoWORPIfDDRS 16 }
oriWORPIfDDRSMinReqSNRdot11at72Mbps OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to specify the minimum required SNR for data rate
of 72Mbps on 802.11a radio, turbo mode. The value should be
in dB and in the range 0..50 dB. The default value should be 18dB."
DEFVAL { 18 }
::= { orinocoWORPIfDDRS 17 }
oriWORPIfDDRSMinReqSNRdot11at96Mbps OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to specify the minimum required SNR for data rate
of 96Mbps on 802.11a radio, turbo mode. The value should be
in dB and in the range 0..50 dB. The default value should be 22dB."
DEFVAL { 22 }
::= { orinocoWORPIfDDRS 18 }
oriWORPIfDDRSMinReqSNRdot11at108Mbps OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to specify the minimum required SNR for data rate
of 108Mbps on 802.11a radio, turbo mode. The value should be
in dB and in the range 0..50 dB. The default value should be 25dB."
DEFVAL { 25 }
::= { orinocoWORPIfDDRS 19 }
oriWORPIfDDRSDataRateIncAvgSNRThreshold OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to specify average SNR threshold for data rate increase.
The value should be in dB and in the range 0..50 dB.
The default value should be 4 dB."
DEFVAL { 4 }
::= { orinocoWORPIfDDRS 20 }
oriWORPIfDDRSDataRateIncReqSNRThreshold OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to specify average SNR threshold for data rate decrease.
The value should be in dB and in the range 0..50 dB.
The default value should be 6 dB."
DEFVAL { 6 }
::= { orinocoWORPIfDDRS 21 }
oriWORPIfDDRSDataRateDecReqSNRThreshold OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to specify SNRreq threshold for data rate reduction.
The value should be in dB and in the range 0..50 dB.
The default value should be 3 dB."
DEFVAL { 3 }
::= { orinocoWORPIfDDRS 22 }
oriWORPIfDDRSDataRateIncPercentThreshold OBJECT-TYPE
SYNTAX INTEGER (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the threshold percentage of retransmissions for
DDRS data rate increase."
DEFVAL { 2 }
::= { orinocoWORPIfDDRS 23 }
oriWORPIfDDRSDataRateDecPercentThreshold OBJECT-TYPE
SYNTAX INTEGER (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the threshold percentage of retransmissions for
DDRS data rate decrease."
DEFVAL { 10 }
::= { orinocoWORPIfDDRS 24 }
--=============================================================================
-- The WORP Interface Roaming Group
--=============================================================================
oriWORPIfRoamingStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable/disable Roaming between BSUs."
::= { orinocoWORPIfRoaming 1 }
oriWORPIfRoamingSlowScanThreshold OBJECT-TYPE
SYNTAX Integer32 (0..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the threshold for initiating slow scanning
procedure. The units of this object is dBs."
DEFVAL { 12 }
::= { orinocoWORPIfRoaming 2 }
oriWORPIfRoamingFastScanThreshold OBJECT-TYPE
SYNTAX Integer32 (0..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the threshold for initiating fast scanning
procedure. The units of this object is dBs."
DEFVAL { 6 }
::= { orinocoWORPIfRoaming 3 }
oriWORPIfRoamingThreshold OBJECT-TYPE
SYNTAX Integer32 (0..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the threshold for roaming threshold.
The units of this object is dBs."
DEFVAL { 3 }
::= { orinocoWORPIfRoaming 4 }
oriWORPIfRoamingSlowScanPercentThreshold OBJECT-TYPE
SYNTAX INTEGER (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the threshold percentage of retransmissions for initiating slow scanning
procedure."
DEFVAL { 2 }
::= { orinocoWORPIfRoaming 5 }
oriWORPIfRoamingFastScanPercentThreshold OBJECT-TYPE
SYNTAX INTEGER (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the threshold percentage of retransmissions for initiating fast scanning
procedure."
DEFVAL { 10 }
::= { orinocoWORPIfRoaming 6 }
--=============================================================================
-- The orinocoWORPIfBSUStat sub group under orinoco WORP group - START
--=============================================================================
orinocoWORPIfBSUStatMACAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the MAC address of BSU to which the SU
is registered."
::= { orinocoWORPIfBSUStat 1 }
orinocoWORPIfBSUStatLocalTxRate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the Transmit Data Rate of the SU."
::= { orinocoWORPIfBSUStat 2 }
orinocoWORPIfBSUStatRemoteTxRate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the Transmit Data Rate of the BSU
to which the SU is registered."
::= { orinocoWORPIfBSUStat 3 }
orinocoWORPIfBSUStatAverageLocalSignal OBJECT-TYPE
SYNTAX Integer32 (-102..-10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current signal level calculated over all inbound packets.
This variable indicates the running average of the SU's local
signal level using the algorithm (3/4*oldvalue + 1/4*newvalue)."
::= { orinocoWORPIfBSUStat 4 }
orinocoWORPIfBSUStatAverageLocalNoise OBJECT-TYPE
SYNTAX Integer32 (-102..-10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current noise level calculated over all inbound packets.
This variable indicates the running average of the SU's
local noise level using the algorithm (3/4*oldvalue + 1/4*newvalue)."
::= { orinocoWORPIfBSUStat 5 }
orinocoWORPIfBSUStatAverageRemoteSignal OBJECT-TYPE
SYNTAX Integer32 (-102..-10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current remote signal level calculated over the inbound
packets received at SU, sent by the BSU. This variable indicates the
running average of the SU's Rx Signal level(i.e. BSU's Tx Signal level)
all registered stations of the remote signal level using the
algorithm (3/4*oldvalue + 1/4*newvalue)."
::= { orinocoWORPIfBSUStat 6 }
orinocoWORPIfBSUStatAverageRemoteNoise OBJECT-TYPE
SYNTAX Integer32 (-102..-10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current remote noise level calculated over the inbound
packets received at SU, sent by the BSU. This variable indicates the
running average of the SU's Rx Noise level(i.e. BSU's Tx Noise level)
all registered stations of the remote noise level using the
algorithm (3/4*oldvalue + 1/4*newvalue)."
::= { orinocoWORPIfBSUStat 7 }
--=============================================================================
-- The Network Group: orinocoNet
--=============================================================================
--=============================================================================
-- The Network IP Subgroup: orinocoNetIP
--=============================================================================
oriNetworkIPConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriNetworkIPConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the Network IP configuration for the network
interface(s) of the device. For bridge mode, only the address
assigned to the Ethernet interface (index 1) will be used."
::= { orinocoNetIP 1 }
oriNetworkIPConfigTableEntry OBJECT-TYPE
SYNTAX OriNetworkIPConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry for the network IP configuration
for each interface in the system."
INDEX { oriNetworkIPConfigTableIndex }
::= { oriNetworkIPConfigTable 1 }
OriNetworkIPConfigTableEntry ::=
SEQUENCE
{
oriNetworkIPConfigTableIndex Integer32,
oriNetworkIPConfigIPAddress IpAddress,
oriNetworkIPConfigSubnetMask IpAddress
}
oriNetworkIPConfigTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents an index or interface number in the
network IP configuration table."
::= { oriNetworkIPConfigTableEntry 1 }
oriNetworkIPConfigIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the IP Address of the network interface."
::= { oriNetworkIPConfigTableEntry 2 }
oriNetworkIPConfigSubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the subnet mask of the network interface."
::= { oriNetworkIPConfigTableEntry 3 }
oriNetworkIPDefaultRouterIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the IP address of the gateway or router
of the device."
::= { orinocoNetIP 3 }
oriNetworkIPDefaultTTL OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The default value inserted into the Time-To-Live (TTL) field of
the IP header of datagrams originated at this entity, whenever a
TTL value is not supplied by the transport layer protocol."
DEFVAL { 64 }
::= { orinocoNetIP 4 }
oriNetworkIPAddressType OBJECT-TYPE
SYNTAX INTEGER
{
static(1),
dynamic(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies if the device is configured to be
assigned a static or dynamic IP address using a DHCP client."
DEFVAL { dynamic }
::= { orinocoNetIP 5 }
--=============================================================================
-- The SNMP Group: orinocoSNMP
--=============================================================================
oriSNMPReadPassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the read-only community name used in the
SNMP protocol. This object is used for reading objects from the
SNMP agent. This object should be treated as write-only and
returned as asterisks."
DEFVAL { "public" }
::= { orinocoSNMP 1 }
oriSNMPReadWritePassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This objecgt represents the read-write community name used in
the SNMP protocol. This object is used for reading and writing
objects to and from the SNMP Agent. This object should be treated
as write-only and returned as asterisks."
DEFVAL { "public" }
::= { orinocoSNMP 2 }
oriSNMPAuthorizedManagerCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reflects the number of entries in the Management IP
Access Table."
::= { orinocoSNMP 3 }
oriSNMPAccessTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriSNMPAccessTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used configure management stations that are
authorized to manage the device. This table applies to the
supported management services/interfaces (SNMP, HTTP, and Telnet).
This table is limited to 20 entries."
::= { orinocoSNMP 4 }
oriSNMPAccessTableEntry OBJECT-TYPE
SYNTAX OriSNMPAccessTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object identifies an entry in the Management IP Access
Table."
INDEX { oriSNMPAccessTableIndex }
::= { oriSNMPAccessTable 1 }
OriSNMPAccessTableEntry ::=
SEQUENCE
{
oriSNMPAccessTableIndex Integer32,
oriSNMPAccessTableIPAddress IpAddress,
oriSNMPAccessTableIPMask IpAddress,
oriSNMPAccessTableInterfaceBitmask InterfaceBitmask,
oriSNMPAccessTableComment DisplayString,
oriSNMPAccessTableEntryStatus INTEGER
}
oriSNMPAccessTableIndex OBJECT-TYPE
SYNTAX Integer32 (0..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the index for the Management IP Access
Table."
::= { oriSNMPAccessTableEntry 1 }
oriSNMPAccessTableIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the IP address of the management station
authorized to manage the device."
::= { oriSNMPAccessTableEntry 2 }
oriSNMPAccessTableIPMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the IP subnet mask. This object can
be used to grant access to a complete subnet."
::= { oriSNMPAccessTableEntry 3 }
oriSNMPAccessTableInterfaceBitmask OBJECT-TYPE
SYNTAX InterfaceBitmask
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to control the interface access for each
table entry in the Management IP Access Table."
::= { oriSNMPAccessTableEntry 4 }
oriSNMPAccessTableComment OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for an optional comment associated to the
Management IP Access Table entry."
::= { oriSNMPAccessTableEntry 5 }
oriSNMPAccessTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable, disable, delete, or create an
entry in the Management IP Access Table."
::= { oriSNMPAccessTableEntry 6 }
oriSNMPTrapHostTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriSNMPTrapHostTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the information regarding the trap host that
will receive SNMP traps sent by the device. This table is limited
10 entries."
::= { orinocoSNMP 5 }
oriSNMPTrapHostTableEntry OBJECT-TYPE
SYNTAX OriSNMPTrapHostTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object identifies an entry in the SNMP Trap Host Table."
INDEX { oriSNMPTrapHostTableIndex }
::= { oriSNMPTrapHostTable 1 }
OriSNMPTrapHostTableEntry ::=
SEQUENCE
{
oriSNMPTrapHostTableIndex Integer32,
oriSNMPTrapHostTableIPAddress IpAddress,
oriSNMPTrapHostTablePassword DisplayString,
oriSNMPTrapHostTableComment DisplayString,
oriSNMPTrapHostTableEntryStatus INTEGER
}
oriSNMPTrapHostTableIndex OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as an index for the SNMP Trap Host Table."
::= { oriSNMPTrapHostTableEntry 1 }
oriSNMPTrapHostTableIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the IP address of the management station
that will receive SNMP Traps from the device."
::= { oriSNMPTrapHostTableEntry 2 }
oriSNMPTrapHostTablePassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the password that is sent with the SNMP
trap messages to allow the host to accept or reject the traps.
The trap host will only accept SNMP traps if this password matches
the host's password. This object should be treated as write-only
and returned as asterisks."
::= { oriSNMPTrapHostTableEntry 3 }
oriSNMPTrapHostTableComment OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for an optional comment associated to the
SNMP Trap Host Table entry."
::= { oriSNMPTrapHostTableEntry 4 }
oriSNMPTrapHostTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable, disable, delete, create an
entry in the SNMP Trap Host Table."
::= { oriSNMPTrapHostTableEntry 5 }
oriSNMPInterfaceBitmask OBJECT-TYPE
SYNTAX InterfaceBitmask
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to control the interface access for SNMP
based management (not HTTP and Telnet)."
::= { orinocoSNMP 7 }
oriSNMPErrorMessage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to provide additional information in case of
an SNMP error."
::= { orinocoSNMP 8 }
oriSNMPAccessTableStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the Management IP Access
Table. If this object is disabled, the check based on source IP
address for the enteries in the Management IP Access Table will not
be performed."
::= { orinocoSNMP 9 }
oriSNMPTrapType OBJECT-TYPE
SYNTAX INTEGER
{
snmp-v1(1),
snmp-v2c(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the SNMP trap/notification type
that will be generated."
DEFVAL { snmp-v1 }
::= { orinocoSNMP 10 }
oriSNMPSecureManagementStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the secure Management
feature for the Access Point. With this object enabled, view
based access control will be enforced on all forms of management
including SNMPv1/v2c, HTTP, WEB, HTTPS, SSH, serial, and Telnet.
Also SNMPv3 user security model will be enabled. The default SNMPv3
user is defined as userName 'administrator', with SHA authentication
and DES privacy protocols."
DEFVAL { disable }
::= { orinocoSNMP 11 }
oriSNMPV3AuthPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE(6..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the SNMPv3 administrator authentication
password. This object should be treated as write-only and returned
as asterisks."
DEFVAL { "public" }
::= { orinocoSNMP 12 }
oriSNMPV3PrivPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE(6..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the SNMPv3 administrator privacy password.
This object should be treated as write-only and returned as asterisks."
DEFVAL { "public" }
::= { orinocoSNMP 13 }
--=============================================================================
-- The Protocol Filtering Subgroup: orinocoProtocolFilter
--=============================================================================
oriProtocolFilterOperationType OBJECT-TYPE
SYNTAX INTEGER
{
passthru(1),
block(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to passthru (allow) or block (deny) packets
with protocols in the protocol filter table."
DEFVAL { block }
::= { orinocoProtocolFilter 1 }
oriProtocolFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriProtocolFilterTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the two byte hexadecimal values of the
protocols. The packets whose protocol field matches with any of
the entries in this table will be forwarded or dropped based on
value of oriProtocolFilterFlag. This table is limited to 256
ethernet protocols (enteries)."
::= { orinocoProtocolFilter 2 }
oriProtocolFilterTableEntry OBJECT-TYPE
SYNTAX OriProtocolFilterTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the protocol filter table."
INDEX { oriProtocolFilterTableIndex }
::= { oriProtocolFilterTable 1 }
OriProtocolFilterTableEntry ::=
SEQUENCE
{
oriProtocolFilterTableIndex Integer32,
oriProtocolFilterProtocol OCTET STRING,
oriProtocolFilterProtocolComment DisplayString,
oriProtocolFilterTableEntryStatus INTEGER,
oriProtocolFilterTableInterfaceBitmask InterfaceBitmask,
oriProtocolFilterProtocolString DisplayString
}
oriProtocolFilterTableIndex OBJECT-TYPE
SYNTAX Integer32 (0..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to index the protocol filter table."
::= { oriProtocolFilterTableEntry 1 }
oriProtocolFilterProtocol OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents a two byte hexadecimal value for the
Ethernet protocol to be filtered (the protocol field of the
Ethernet packet)."
::= { oriProtocolFilterTableEntry 2 }
oriProtocolFilterProtocolComment OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used as an optional comment for the ethernet
protocol to be filtered."
::= { oriProtocolFilterTableEntry 3 }
oriProtocolFilterTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable, disable, delete, create the
Ethernet protocols in this table."
::= { oriProtocolFilterTableEntry 4 }
oriProtocolFilterTableInterfaceBitmask OBJECT-TYPE
SYNTAX InterfaceBitmask
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is isued to control protocol filtering per interface
for each entry in this table."
::= { oriProtocolFilterTableEntry 5 }
oriProtocolFilterProtocolString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the value in the protocol field of the
Ethernet packet. The value is of 4-digit Hex format.
Example: The value of IP protocol is 0800.
The value of ARP protocol is 0806."
::= { oriProtocolFilterTableEntry 6}
oriProtocolFilterInterfaceBitmask OBJECT-TYPE
SYNTAX InterfaceBitmask
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is isued to control protocol filtering per interface
for the table."
::= { orinocoProtocolFilter 3 }
--=============================================================================
-- The Access Control Subgroup: orinocoAccessControl
--=============================================================================
oriAccessControlStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable MAC Access Control
feature/filter in the device."
DEFVAL { disable }
::= { orinocoAccessControl 1 }
oriAccessControlOperationType OBJECT-TYPE
SYNTAX INTEGER
{
passthru(1),
block(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This flag determines whether the stations with MAC addresses
listed in the access control table will be allowed or denied
access. This flag is used only if oriAccessControlStatus is
enabled. This table is limited to 1000 MAC Address entries."
DEFVAL { passthru }
::= { orinocoAccessControl 2 }
oriAccessControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriAccessControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the information about MAC addresses of the
wireless stations that are either allowed or disallowed access
(based on oriAccessControlOperation) through this device.
This table is used only if oriAccessControlStatus is enabled."
::= { orinocoAccessControl 3 }
oriAccessControlEntry OBJECT-TYPE
SYNTAX OriAccessControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the entry in the access control table."
INDEX { oriAccessControlTableIndex }
::= { oriAccessControlTable 1 }
OriAccessControlEntry ::=
SEQUENCE
{
oriAccessControlTableIndex Integer32,
oriAccessControlTableMACAddress PhysAddress,
oriAccessControlTableComment DisplayString,
oriAccessControlTableEntryStatus INTEGER
}
oriAccessControlTableIndex OBJECT-TYPE
SYNTAX Integer32 (0..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as an index for the access control table."
::= { oriAccessControlEntry 1 }
oriAccessControlTableMACAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the MAC address of the wireless station
that can access the device."
::= { oriAccessControlEntry 2 }
oriAccessControlTableComment OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used as an optional comment associated to the
access control table entry."
::= { oriAccessControlEntry 3 }
oriAccessControlTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable, disable, delete, create the entries
in the Access Control Table."
::= { oriAccessControlEntry 4 }
--=============================================================================
-- The Static MAC Address Filter Subgroup: orinocoStaticMACAddressFilter
--=============================================================================
oriStaticMACAddressFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriStaticMACAddressFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides the MAC address of the stations on the wired
and the wireless interface; the MAC addresses will be given in
pairs. Stations listed in the Static MAC Address filter will
have no traffic forwarded by the device. This way Multicast
traffic exchanged between stations or servers can be prevented,
from being transmitted over the wireless medium when both stations
are actually located on the wired backbone. This table is limited
to 200 entries."
::= { orinocoStaticMACAddressFilter 1 }
oriStaticMACAddressFilterEntry OBJECT-TYPE
SYNTAX OriStaticMACAddressFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object identifies the entry in the Static MAC address
filter table."
INDEX { oriStaticMACAddressFilterTableIndex }
::= { oriStaticMACAddressFilterTable 1 }
OriStaticMACAddressFilterEntry ::=
SEQUENCE
{
oriStaticMACAddressFilterTableIndex Integer32,
oriStaticMACAddressFilterWiredAddress PhysAddress,
oriStaticMACAddressFilterWiredMask PhysAddress,
oriStaticMACAddressFilterWirelessAddress PhysAddress,
oriStaticMACAddressFilterWirelessMask PhysAddress,
oriStaticMACAddressFilterTableEntryStatus INTEGER,
oriStaticMACAddressFilterComment DisplayString
}
oriStaticMACAddressFilterTableIndex OBJECT-TYPE
SYNTAX Integer32 (0..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as an index for the Static MAC address
filter table."
::= { oriStaticMACAddressFilterEntry 1 }
oriStaticMACAddressFilterWiredAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the MAC address of the station on the
wired interface of the device."
::= { oriStaticMACAddressFilterEntry 2 }
oriStaticMACAddressFilterWiredMask OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This mask determines the presence of wildcard characters in the
MAC address of the station on the wired interface. The value F
(hex digit) in the mask indicates the presence of a wildcard
character and the value 0 indicates its absence."
::= { oriStaticMACAddressFilterEntry 3 }
oriStaticMACAddressFilterWirelessAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the MAC address of the station on the
wireless interface."
::= { oriStaticMACAddressFilterEntry 4 }
oriStaticMACAddressFilterWirelessMask OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The mask that determines the presence of wildcard characters in
the MAC address of the station on the wireless side. The value F
(hex digit) indicates the presence of a wildcard character and the
hex digit 0 indicates its absense."
::= { oriStaticMACAddressFilterEntry 5 }
oriStaticMACAddressFilterTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable, disable, delete, create an entry
in the Static MAC Address Table."
::= { oriStaticMACAddressFilterEntry 6 }
oriStaticMACAddressFilterComment OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for an optional comment associated to the
access control table entry."
::= { oriStaticMACAddressFilterEntry 7 }
--=============================================================================
-- The Storm Threshold Subgroup: orinocoStormThreshold
--=============================================================================
oriBroadcastAddressThreshold OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If broadcast rate from any device (identified by its MAC address)
exceeds the limit specified by this value, the device will
ignore all subsequent messages issued by the particular network
device, or ignore all messages of that type. Valid values for
address threshold is between 0 - 255 frames per second. Initial
Value is 0 (Disable Storm Threshold Protection)."
DEFVAL { 0 }
::= { orinocoStormThreshold 1 }
oriMulticastAddressThreshold OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If multicast rate from any device (identified by its MAC address)
exceeds the limit specified by this value, the device will
ignore all subsequent messages issued by the particular network
device, or ignore all messages of that type. Valid values for
address threshold is between 0 - 255 frames per second. Initial
Value is 0 (Disable Storm Threshold Protection)."
DEFVAL { 0 }
::= { orinocoStormThreshold 2 }
oriStormThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriStormThresholdTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table containing broadcast and multicast threshold values for
each interface."
::= { orinocoStormThreshold 3 }
oriStormThresholdTableEntry OBJECT-TYPE
SYNTAX OriStormThresholdTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the storm threshold filter
table."
INDEX { ifIndex }
::= { oriStormThresholdTable 1 }
OriStormThresholdTableEntry ::=
SEQUENCE
{
oriStormThresholdIfBroadcast Integer32,
oriStormThresholdIfMulticast Integer32
}
oriStormThresholdIfBroadcast OBJECT-TYPE
SYNTAX Integer32 (0..9999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter specifies a set of Broadcast Storm thresholds for
each interface/port of the device, identifying separate
values for the number of Broadcast messages/second. Default value
is zero, which means disabled."
DEFVAL { 0 }
::= { oriStormThresholdTableEntry 1 }
oriStormThresholdIfMulticast OBJECT-TYPE
SYNTAX Integer32 (0..9999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter specifies a set of Multicast Storm thresholds for
each interface/port of the device, identifying separate
values for the number of Multicast messages/second. Default value
is zero, which means disabled."
DEFVAL { 0 }
::= { oriStormThresholdTableEntry 2 }
--=============================================================================
-- The Port Filtering Subgroup: orinocoPortFilter
-- Filtering per Interface based on IP Address and Port Number.
--=============================================================================
oriPortFilterStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable port filtering."
DEFVAL { disable }
::= { orinocoPortFilter 1 }
oriPortFilterOperationType OBJECT-TYPE
SYNTAX INTEGER
{
passthru(1),
block(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines whether the stations with ports
listed in the port filter table must be allowed (passthru) or
denied (block) to access the device. This object is used only if
oriPacketFilterStatus is enabled."
DEFVAL { passthru }
::= { orinocoPortFilter 2 }
oriPortFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriPortFilterTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the Port number of packets to be filtered.
The packets whose port field matches with any of the enabled entries in
this table will be blocked (dropped). This table is limited to
256 entries."
::= { orinocoPortFilter 3 }
oriPortFilterTableEntry OBJECT-TYPE
SYNTAX OriPortFilterTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This parameter represents the entry in the port filter table."
INDEX { oriPortFilterTableEntryIndex }
::= { oriPortFilterTable 1 }
OriPortFilterTableEntry ::=
SEQUENCE
{
oriPortFilterTableEntryIndex Integer32,
oriPortFilterTableEntryPort Integer32,
oriPortFilterTableEntryPortType INTEGER,
oriPortFilterTableEntryInterfaceBitmask InterfaceBitmask,
oriPortFilterTableEntryComment DisplayString,
oriPortFilterTableEntryStatus INTEGER
}
oriPortFilterTableEntryIndex OBJECT-TYPE
SYNTAX Integer32 (0..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as the index for the port filter table. This
table supports up to 256 entries."
::= { oriPortFilterTableEntry 1 }
oriPortFilterTableEntryPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the port number of the packets to be
filtered."
::= { oriPortFilterTableEntry 2 }
oriPortFilterTableEntryPortType OBJECT-TYPE
SYNTAX INTEGER
{
tcp(1),
udp(2),
both(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the port type."
::= { oriPortFilterTableEntry 3 }
oriPortFilterTableEntryInterfaceBitmask OBJECT-TYPE
SYNTAX InterfaceBitmask
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to control port filtering per interface for
each entry in the table."
::= { oriPortFilterTableEntry 4 }
oriPortFilterTableEntryComment OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for an optional comment associated to the
port filter table entry."
::= { oriPortFilterTableEntry 5 }
oriPortFilterTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable, disable, delete, create an entry
in the Port Filter Table."
::= { oriPortFilterTableEntry 6 }
--=============================================================================
-- The Advanced Bridge Filtering Subgroup: orinocoAdvancedFiltering
--=============================================================================
oriBroadcastFilteringTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriBroadcastFilteringTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table entries for broadcast filters. This table shall contain
5 entries."
::= { orinocoAdvancedFiltering 1 }
oriBroadcastFilteringTableEntry OBJECT-TYPE
SYNTAX OriBroadcastFilteringTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the broadcast filtering
table."
INDEX { oriBroadcastFilteringTableIndex }
::= { oriBroadcastFilteringTable 1 }
OriBroadcastFilteringTableEntry ::=
SEQUENCE
{
oriBroadcastFilteringTableIndex Integer32,
oriBroadcastFilteringProtocolName DisplayString,
oriBroadcastFilteringDirection INTEGER,
oriBroadcastFilteringTableEntryStatus INTEGER
}
oriBroadcastFilteringTableIndex OBJECT-TYPE
SYNTAX Integer32 (0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the index of the Broadcast Filtering
table."
::= { oriBroadcastFilteringTableEntry 1 }
oriBroadcastFilteringProtocolName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the broadcast protocol name to
be filtered."
::= { oriBroadcastFilteringTableEntry 2 }
oriBroadcastFilteringDirection OBJECT-TYPE
SYNTAX INTEGER
{
ethernetToWireless(1),
wirelessToEthernet(2),
both(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the direction of the broadcast filter.
The filter can be enabled for Ethernet to Wireless, Wireless
to Ethernet, or both directions."
::= { oriBroadcastFilteringTableEntry 3 }
oriBroadcastFilteringTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the broadcast filter
table enteries."
::= { oriBroadcastFilteringTableEntry 4 }
--=============================================================================
-- The Packet Forwarding Subgroup: orinocoPacketForwarding
--=============================================================================
oriPacketForwardingStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the Packet Forwarding
feature."
DEFVAL { disable }
::= { orinocoPacketForwarding 1 }
oriPacketForwardingMACAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the MAC Address to which all frames will be
forwarded by the device."
::= { orinocoPacketForwarding 2 }
oriPacketForwardingInterface OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the interface or port that frames
will be forwarded to. If this object is not configured, value set
to zero, then the bridge will forward the packets on the interface
or port the MAC address was learned on. If this object is not
configured, value set to zero, and the bridge has not yet learned the
MAC address then the frames will be forwarded on all interfaces and
ports."
::= { orinocoPacketForwarding 3 }
--=============================================================================
-- The IntraBSS Traffic Control Subgroup
--=============================================================================
oriIBSSTrafficOperation OBJECT-TYPE
SYNTAX INTEGER
{
passthru(1),
block(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to control IntraBSS Traffic. If this object
is set to the passthru, then IBSS traffic will be allowed; if this
object is set to block, then IBSS traffic will be denied."
DEFVAL { passthru }
::= { orinocoIBSSTraffic 1 }
--=============================================================================
-- The IntraCellBlocking Subgroup
--=============================================================================
oriIntraCellBlockingStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable/disable IntraCell Blocking/Filtering."
DEFVAL { disable }
::= { orinocoIntraCellBlocking 1 }
oriIntraCellBlockingMACTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriIntraCellBlockingMACTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MAC table entries for IntraCell Blocking filters. This table
can contain up to a maximum of 250 entries."
::= { orinocoIntraCellBlocking 2 }
oriIntraCellBlockingMACTableEntry OBJECT-TYPE
SYNTAX OriIntraCellBlockingMACTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the entry in the IntraCell Blocking MAC Table."
INDEX { oriIntraCellBlockingMACTableIndex }
::= { oriIntraCellBlockingMACTable 1 }
OriIntraCellBlockingMACTableEntry ::=
SEQUENCE
{
oriIntraCellBlockingMACTableIndex Integer32,
oriIntraCellBlockingMACTableMACAddress PhysAddress,
oriIntraCellBlockingMACTableGroupID1 ObjStatusActive,
oriIntraCellBlockingMACTableGroupID2 ObjStatusActive,
oriIntraCellBlockingMACTableGroupID3 ObjStatusActive,
oriIntraCellBlockingMACTableGroupID4 ObjStatusActive,
oriIntraCellBlockingMACTableGroupID5 ObjStatusActive,
oriIntraCellBlockingMACTableGroupID6 ObjStatusActive,
oriIntraCellBlockingMACTableGroupID7 ObjStatusActive,
oriIntraCellBlockingMACTableGroupID8 ObjStatusActive,
oriIntraCellBlockingMACTableGroupID9 ObjStatusActive,
oriIntraCellBlockingMACTableGroupID10 ObjStatusActive,
oriIntraCellBlockingMACTableGroupID11 ObjStatusActive,
oriIntraCellBlockingMACTableGroupID12 ObjStatusActive,
oriIntraCellBlockingMACTableGroupID13 ObjStatusActive,
oriIntraCellBlockingMACTableGroupID14 ObjStatusActive,
oriIntraCellBlockingMACTableGroupID15 ObjStatusActive,
oriIntraCellBlockingMACTableGroupID16 ObjStatusActive,
oriIntraCellBlockingMACTableEntryStatus INTEGER
}
oriIntraCellBlockingMACTableIndex OBJECT-TYPE
SYNTAX Integer32 (1..250)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as the index to the IntraCell Blocking MAC Table."
::= { oriIntraCellBlockingMACTableEntry 1 }
oriIntraCellBlockingMACTableMACAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the MAC address of the SU which is allowed to
communicate with other SUs with the same group ID."
::= { oriIntraCellBlockingMACTableEntry 2 }
oriIntraCellBlockingMACTableGroupID1 OBJECT-TYPE
SYNTAX ObjStatusActive
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to activate/deactivate Group ID 1."
DEFVAL { inactive }
::= { oriIntraCellBlockingMACTableEntry 3 }
oriIntraCellBlockingMACTableGroupID2 OBJECT-TYPE
SYNTAX ObjStatusActive
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to activate/deactivate Group ID 2."
DEFVAL { inactive }
::= { oriIntraCellBlockingMACTableEntry 4 }
oriIntraCellBlockingMACTableGroupID3 OBJECT-TYPE
SYNTAX ObjStatusActive
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to activate/deactivate Group ID 3."
DEFVAL { inactive }
::= { oriIntraCellBlockingMACTableEntry 5 }
oriIntraCellBlockingMACTableGroupID4 OBJECT-TYPE
SYNTAX ObjStatusActive
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to activate/deactivate Group ID 4."
DEFVAL { inactive }
::= { oriIntraCellBlockingMACTableEntry 6 }
oriIntraCellBlockingMACTableGroupID5 OBJECT-TYPE
SYNTAX ObjStatusActive
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to activate/deactivate Group ID 5."
DEFVAL { inactive }
::= { oriIntraCellBlockingMACTableEntry 7 }
oriIntraCellBlockingMACTableGroupID6 OBJECT-TYPE
SYNTAX ObjStatusActive
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to activate/deactivate Group ID 6."
DEFVAL { inactive }
::= { oriIntraCellBlockingMACTableEntry 8 }
oriIntraCellBlockingMACTableGroupID7 OBJECT-TYPE
SYNTAX ObjStatusActive
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to activate/deactivate Group ID 7."
DEFVAL { inactive }
::= { oriIntraCellBlockingMACTableEntry 9 }
oriIntraCellBlockingMACTableGroupID8 OBJECT-TYPE
SYNTAX ObjStatusActive
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to activate/deactivate Group ID 8."
DEFVAL { inactive }
::= { oriIntraCellBlockingMACTableEntry 10 }
oriIntraCellBlockingMACTableGroupID9 OBJECT-TYPE
SYNTAX ObjStatusActive
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to activate/deactivate Group ID 9."
DEFVAL { inactive }
::= { oriIntraCellBlockingMACTableEntry 11 }
oriIntraCellBlockingMACTableGroupID10 OBJECT-TYPE
SYNTAX ObjStatusActive
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to activate/deactivate Group ID 10."
DEFVAL { inactive }
::= { oriIntraCellBlockingMACTableEntry 12 }
oriIntraCellBlockingMACTableGroupID11 OBJECT-TYPE
SYNTAX ObjStatusActive
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to activate/deactivate Group ID 11."
DEFVAL { inactive }
::= { oriIntraCellBlockingMACTableEntry 13 }
oriIntraCellBlockingMACTableGroupID12 OBJECT-TYPE
SYNTAX ObjStatusActive
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to activate/deactivate Group ID 12."
DEFVAL { inactive }
::= { oriIntraCellBlockingMACTableEntry 14 }
oriIntraCellBlockingMACTableGroupID13 OBJECT-TYPE
SYNTAX ObjStatusActive
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to activate/deactivate Group ID 13."
DEFVAL { inactive }
::= { oriIntraCellBlockingMACTableEntry 15 }
oriIntraCellBlockingMACTableGroupID14 OBJECT-TYPE
SYNTAX ObjStatusActive
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to activate/deactivate Group ID 14."
DEFVAL { inactive }
::= { oriIntraCellBlockingMACTableEntry 16 }
oriIntraCellBlockingMACTableGroupID15 OBJECT-TYPE
SYNTAX ObjStatusActive
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to activate/deactivate Group ID 15."
DEFVAL { inactive }
::= { oriIntraCellBlockingMACTableEntry 17 }
oriIntraCellBlockingMACTableGroupID16 OBJECT-TYPE
SYNTAX ObjStatusActive
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to activate/deactivate Group ID 16."
DEFVAL { inactive }
::= { oriIntraCellBlockingMACTableEntry 18 }
oriIntraCellBlockingMACTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable, disable, delete, create the entries
in the IntraCell Blocking MAC Table."
DEFVAL { enable }
::= { oriIntraCellBlockingMACTableEntry 19 }
oriIntraCellBlockingGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriIntraCellBlockingGroupTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Group table entries for IntraCell Blocking Group IDs.
This table can contain a maximum of 16 entries."
::= { orinocoIntraCellBlocking 3 }
oriIntraCellBlockingGroupTableEntry OBJECT-TYPE
SYNTAX OriIntraCellBlockingGroupTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the entry in the IntraCell Blocking
Group Table."
INDEX { oriIntraCellBlockingGroupTableIndex }
::= { oriIntraCellBlockingGroupTable 1 }
OriIntraCellBlockingGroupTableEntry ::=
SEQUENCE
{
oriIntraCellBlockingGroupTableIndex Integer32,
oriIntraCellBlockingGroupTableName DisplayString,
oriIntraCellBlockingGroupTableEntryStatus INTEGER
}
oriIntraCellBlockingGroupTableIndex OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as the index to the IntraCell Blocking
Group Table."
::= { oriIntraCellBlockingGroupTableEntry 1 }
oriIntraCellBlockingGroupTableName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the group name."
::= { oriIntraCellBlockingGroupTableEntry 2 }
oriIntraCellBlockingGroupTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable, disable, delete, create the entries
in the IntraCell Blocking Group Table."
DEFVAL { disable }
::= { oriIntraCellBlockingGroupTableEntry 3 }
--=============================================================================
-- Packet Forwarding to Security Gateway Subgroup: orinocoSecurityGw
--=============================================================================
oriSecurityGwStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable/disable the Security Gateway feature."
DEFVAL { disable }
::= { orinocoSecurityGw 1 }
oriSecurityGwMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the Security Gateway MAC Address to which
all frames will be forwarded by the device."
::= { orinocoSecurityGw 2 }
--=============================================================================
-- The RADIUS Group: orinocoRADIUS
--=============================================================================
oriRADIUSClientInvalidServerAddress OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter represents the total number of RADIUS access-response
messages received from an unknown address since system startup."
::= { orinocoRADIUS 3 }
oriRADIUSMACAccessControl OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enables RADIUS Access Control based on
wireless stations MAC Address."
DEFVAL { disable }
::= { orinocoRADIUS 4 }
oriRADIUSAuthorizationLifeTime OBJECT-TYPE
SYNTAX Integer32 (0|7200..43200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the authorization lifetime for a certain
MAC based RADIUS authenticated client. A value of zero (0) means that
re-authorization is disabled. The units for this object is seconds."
DEFVAL { 0 }
::= { orinocoRADIUS 5 }
oriRADIUSMACAddressFormat OBJECT-TYPE
SYNTAX INTEGER
{
dashDelimited(1),
colonDelimited(2),
singleDashDelimited(3),
noDelimiter(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the MAC Address format that is to be
used for communication with the RADIUS Server.
Examples of MAC Address Format are:
- Dash Delimited: 00-11-22-AA-BB-CC
- Colon Delimited: 00:11:22:AA:BB:CC
- Single Dash Delimited: 001122-AABBCC
- No Delimiter: 001122AABBCC"
DEFVAL { dashDelimited }
::= { orinocoRADIUS 6 }
oriRADIUSLocalUserStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable/disable local user support when RADIUS
based management is enabled."
DEFVAL { disable }
::= { orinocoRADIUS 7 }
oriRADIUSLocalUserPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE(6..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the password to access the device when using the
local username - root. This object should be treated as write-only and
returned as asterisks."
DEFVAL { "public" }
::= { orinocoRADIUS 8 }
oriRADIUSbasedManagementAccessProfile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the RADIUS Server profile that will
be used for RADIUS based management access. The RADIUS profile is
defined in the RADIUS Server Table in the orinocoRADIUSSvrProfile
group."
::= { orinocoRADIUS 9 }
--=============================================================================
-- The RADIUS Authentication Group: orinocoRADIUSAuth
--=============================================================================
oriRADIUSAuthServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriRADIUSAuthServerTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table represents the RADIUS servers that the device will
communicated with for client authentication. Usually this table
should have two members representing the primary and secondary
(backup) RADIUS Authentication Servers."
::= { orinocoRADIUSAuth 1 }
oriRADIUSAuthServerTableEntry OBJECT-TYPE
SYNTAX OriRADIUSAuthServerTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the RADIUS Authentication
Server Table."
INDEX { oriRADIUSAuthServerTableIndex }
::= { oriRADIUSAuthServerTable 1 }
OriRADIUSAuthServerTableEntry ::=
SEQUENCE
{
oriRADIUSAuthServerTableIndex Integer32,
oriRADIUSAuthServerType INTEGER,
oriRADIUSAuthServerTableEntryStatus INTEGER,
oriRADIUSAuthServerIPAddress IpAddress,
oriRADIUSAuthServerDestPort Integer32,
oriRADIUSAuthServerSharedSecret DisplayString,
oriRADIUSAuthServerResponseTime Integer32,
oriRADIUSAuthServerMaximumRetransmission Integer32,
oriRADIUSAuthClientAccessRequests Counter32,
oriRADIUSAuthClientAccessRetransmissions Counter32,
oriRADIUSAuthClientAccessAccepts Counter32,
oriRADIUSAuthClientAccessChallenges Counter32,
oriRADIUSAuthClientAccessRejects Counter32,
oriRADIUSAuthClientMalformedAccessResponses Counter32,
oriRADIUSAuthClientAuthInvalidAuthenticators Counter32,
oriRADIUSAuthClientTimeouts Counter32,
oriRADIUSAuthServerNameOrIPAddress DisplayString,
oriRADIUSAuthServerAddressingFormat INTEGER
}
oriRADIUSAuthServerTableIndex OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as an index to the RADIUS Authentication
Server Table."
::= { oriRADIUSAuthServerTableEntry 1 }
oriRADIUSAuthServerType OBJECT-TYPE
SYNTAX INTEGER
{
authentication(1),
accounting(2),
authAndAcct(3),
authdot1x(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates if the RADIUS server will provide
Authentication service, Accounting service, or both."
::= { oriRADIUSAuthServerTableEntry 2 }
oriRADIUSAuthServerTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies if the RADIUS server entry is enabled or
disabled."
::= { oriRADIUSAuthServerTableEntry 3 }
oriRADIUSAuthServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object represents the IP address of the RADIUS server."
::= { oriRADIUSAuthServerTableEntry 4 }
oriRADIUSAuthServerDestPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the RADIUS server authentication port -
the default value is 1812."
DEFVAL { 1812 }
::= { oriRADIUSAuthServerTableEntry 5 }
oriRADIUSAuthServerSharedSecret OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the shared secret between the RADIUS
server and client. This object should be treated as write-only
and returned as asterisks."
::= { oriRADIUSAuthServerTableEntry 6 }
oriRADIUSAuthServerResponseTime OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the time (in seconds) for which the
RADIUS client will wait, until another authentication request is
sent to the server."
DEFVAL { 3 }
::= { oriRADIUSAuthServerTableEntry 7 }
oriRADIUSAuthServerMaximumRetransmission OBJECT-TYPE
SYNTAX Integer32 (0..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the number of retransmissions of
authentication requests by the RADIUS Client to the Server."
DEFVAL { 3 }
::= { oriRADIUSAuthServerTableEntry 8 }
oriRADIUSAuthClientAccessRequests OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of RADIUS Access Requests
messages transmitted from the client to the server since client
startup."
::= { oriRADIUSAuthServerTableEntry 9 }
oriRADIUSAuthClientAccessRetransmissions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of RADIUS Access Requests
retransmitted by the client to the server since system startup."
::= { oriRADIUSAuthServerTableEntry 10 }
oriRADIUSAuthClientAccessAccepts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of RADIUS Access Accept messages
received since system startup."
::= { oriRADIUSAuthServerTableEntry 11 }
oriRADIUSAuthClientAccessChallenges OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of RADIUS Access Challenges
messages received since system startup."
::= { oriRADIUSAuthServerTableEntry 12 }
oriRADIUSAuthClientAccessRejects OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of RADIUS Access Rejects
messages received since system startup."
::= { oriRADIUSAuthServerTableEntry 13 }
oriRADIUSAuthClientMalformedAccessResponses OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of malformed RADIUS Access
Response messages received since system startup."
::= { oriRADIUSAuthServerTableEntry 14 }
oriRADIUSAuthClientAuthInvalidAuthenticators OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of malformed RADIUS Access
Response messages containing invalid authenticators received since
system startup."
::= { oriRADIUSAuthServerTableEntry 15 }
oriRADIUSAuthClientTimeouts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the total number of timeouts for RADIUS
Access Request messages since system startup."
::= { oriRADIUSAuthServerTableEntry 16 }
oriRADIUSAuthServerNameOrIPAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to specify the RADIUS Server host name or
IP Address."
::= { oriRADIUSAuthServerTableEntry 17 }
oriRADIUSAuthServerAddressingFormat OBJECT-TYPE
SYNTAX INTEGER
{
ipAddress(1),
name(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to specify the addressing format for configuring
the RADIUS Server. If this object is configured to IP Address, then
IP address should be used to specify the server. If this object is
configured to name, then the host name should be specified."
DEFVAL { ipAddress }
::= { oriRADIUSAuthServerTableEntry 18 }
--=============================================================================
-- The RADIUS Accounting Group: orinocoRADIUSAcct
--=============================================================================
oriRADIUSAcctStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object is used to enable or disable the RADIUS Accounting
service. This object has been deprecated."
DEFVAL { disable }
::= { orinocoRADIUSAcct 1 }
oriRADIUSAcctInactivityTimer OBJECT-TYPE
SYNTAX Integer32 (1..60)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter represents the inactivity or idle timeout in
minutes after which an Accounting Stop request is sent to the
RADIUS Accounting server - the default value is 5 minutes.
This object has been deprecated."
DEFVAL { 5 }
::= { orinocoRADIUSAcct 2 }
oriRADIUSAcctServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriRADIUSAcctServerTableEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This table represents the RADIUS servers that the device will
communicated with for accounting. Usually this table should
have two members representing the primary and secondary (backup)
RADIUS Accounting Servers. This object has been deprecated."
::= { orinocoRADIUSAcct 3 }
oriRADIUSAcctServerTableEntry OBJECT-TYPE
SYNTAX OriRADIUSAcctServerTableEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This object represents an entry into the RADIUS Accouting
Server Table. This object has been deprecated."
INDEX { oriRADIUSAcctServerTableIndex }
::= { oriRADIUSAcctServerTable 1 }
OriRADIUSAcctServerTableEntry ::=
SEQUENCE
{
oriRADIUSAcctServerTableIndex Integer32,
oriRADIUSAcctServerType INTEGER,
oriRADIUSAcctServerTableEntryStatus INTEGER,
oriRADIUSAcctServerIPAddress IpAddress,
oriRADIUSAcctServerDestPort Integer32,
oriRADIUSAcctServerSharedSecret DisplayString,
oriRADIUSAcctServerResponseTime Integer32,
oriRADIUSAcctServerMaximumRetransmission Integer32,
oriRADIUSAcctClientAccountingRequests Counter32,
oriRADIUSAcctClientAccountingRetransmissions Counter32,
oriRADIUSAcctClientAccountingResponses Counter32,
oriRADIUSAcctClientAcctInvalidAuthenticators Counter32,
oriRADIUSAcctServerNameOrIPAddress DisplayString,
oriRADIUSAcctServerAddressingFormat INTEGER
}
oriRADIUSAcctServerTableIndex OBJECT-TYPE
SYNTAX Integer32 (0..2)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object is used as the index to the RADIUS Server Accounting
table. This object has been deprecated."
::= { oriRADIUSAcctServerTableEntry 1 }
oriRADIUSAcctServerType OBJECT-TYPE
SYNTAX INTEGER
{
authentication(1),
accounting(2),
authAndAcct(3)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object indicates if the RADIUS server will provide
Authentication service, Accounting service, or both.
This object has been deprecated."
::= { oriRADIUSAcctServerTableEntry 2 }
oriRADIUSAcctServerTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object identifies if the RADIUS server entry is enabled or
disabled. This object has been deprecated."
::= { oriRADIUSAcctServerTableEntry 3 }
oriRADIUSAcctServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object represents the IP address of the RADIUS server.
This object has been deprecated."
::= { oriRADIUSAcctServerTableEntry 4 }
oriRADIUSAcctServerDestPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object represents the RADIUS server accounting port -
the default value is 1813. This object has been deprecated."
DEFVAL { 1813 }
::= { oriRADIUSAcctServerTableEntry 5 }
oriRADIUSAcctServerSharedSecret OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object represents the shared secret between the RADIUS
server and client. This object should be treated as write-only
and returned as asterisks. This object has been deprecated."
::= { oriRADIUSAcctServerTableEntry 6 }
oriRADIUSAcctServerResponseTime OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object represents the time (in seconds) for which the
RADIUS client will wait, until another accounting request is
sent to the server. This object has been deprecated."
DEFVAL { 3 }
::= { oriRADIUSAcctServerTableEntry 7 }
oriRADIUSAcctServerMaximumRetransmission OBJECT-TYPE
SYNTAX Integer32 (0..4)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object represents the number of retransmissions of
accounting requests by the RADIUS Client to the Server.
This object has been deprecated."
DEFVAL { 3 }
::= { oriRADIUSAcctServerTableEntry 8 }
oriRADIUSAcctClientAccountingRequests OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object represents the number of Accounting Requests messages
sent since system startup. This object has been deprecated."
::= { oriRADIUSAcctServerTableEntry 9 }
oriRADIUSAcctClientAccountingRetransmissions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object represents the number of Accounting Requests
messages retransmitted sent since system startup.
This object has been deprecated."
::= { oriRADIUSAcctServerTableEntry 10 }
oriRADIUSAcctClientAccountingResponses OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object represents the number of Accounting Response messages
received since system startup. This object has been deprecated."
::= { oriRADIUSAcctServerTableEntry 11 }
oriRADIUSAcctClientAcctInvalidAuthenticators OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object represents the number of Accounting Response
messages which contain invalid authenticators received since system
startup. This object has been deprecated."
::= { oriRADIUSAcctServerTableEntry 12 }
oriRADIUSAcctServerNameOrIPAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object is used to specify the RADIUS Server host name or the
IP Address. This object has been deprecated."
::= { oriRADIUSAcctServerTableEntry 13 }
oriRADIUSAcctServerAddressingFormat OBJECT-TYPE
SYNTAX INTEGER
{
ipAddress(1),
name(2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object is used to specify the addressing format for configuring
the RADIUS Server. If this object is configured to IP Address, then
IP address should be used to specify the server. If this object is
configured to name, then the host name should be specified.
This object has been deprecated."
DEFVAL { ipAddress }
::= { oriRADIUSAcctServerTableEntry 14 }
oriRADIUSAcctUpdateInterval OBJECT-TYPE
SYNTAX Integer32 (0..3600)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object is used to specify the interval in seconds at which
RADIUS accounting update messages will be sent.
This object has been deprecated."
::= { orinocoRADIUSAcct 4 }
--=============================================================================
-- The RADIUS Server Profile Table
--=============================================================================
oriRADIUSSvrTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriRADIUSSvrTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table represents the RADIUS server profile that the device will
communicated with for client authentication and/or accounting. This
table has two indices - the first index indicates the profile number
and the second index indicates primary and secondary/backup servers."
::= { orinocoRADIUSSvrProfiles 1 }
oriRADIUSSvrTableEntry OBJECT-TYPE
SYNTAX OriRADIUSSvrTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the RADIUS Server Table."
INDEX { oriRADIUSSvrTableProfileIndex,
oriRADIUSSvrTablePrimaryOrSecondaryIndex }
::= { oriRADIUSSvrTable 1 }
OriRADIUSSvrTableEntry ::=
SEQUENCE
{
oriRADIUSSvrTableProfileIndex Integer32,
oriRADIUSSvrTablePrimaryOrSecondaryIndex Integer32,
oriRADIUSSvrTableProfileName DisplayString,
oriRADIUSSvrTableAddressingFormat INTEGER,
oriRADIUSSvrTableNameOrIPAddress DisplayString,
oriRADIUSSvrTableDestPort Integer32,
oriRADIUSSvrTableSharedSecret DisplayString,
oriRADIUSSvrTableResponseTime Integer32,
oriRADIUSSvrTableMaximumRetransmission Integer32,
oriRADIUSSvrTableVLANID VlanId,
oriRADIUSSvrTableMACAddressFormat INTEGER,
oriRADIUSSvrTableAuthorizationLifeTime Integer32,
oriRADIUSSvrTableAccountingInactivityTimer Integer32,
oriRADIUSSvrTableAccountingUpdateInterval Integer32,
oriRADIUSSvrTableRowStatus RowStatus
}
oriRADIUSSvrTableProfileIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the RADIUS Server profile index."
::= { oriRADIUSSvrTableEntry 1 }
oriRADIUSSvrTablePrimaryOrSecondaryIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is a second index to the RADIUS Server table, which
identifies a server bein primary or secondary/backup."
::= { oriRADIUSSvrTableEntry 2 }
oriRADIUSSvrTableProfileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to specify a unique name for the RADIUS server
profile."
::= { oriRADIUSSvrTableEntry 3 }
oriRADIUSSvrTableAddressingFormat OBJECT-TYPE
SYNTAX INTEGER
{
ipAddress(1),
name(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to specify the addressing format for configuring
the RADIUS Server. If this object is configured to IP Address, then
IP address should be used to specify the server. If this object is
configured to name, then the host name should be specified."
DEFVAL { ipAddress }
::= { oriRADIUSSvrTableEntry 4 }
oriRADIUSSvrTableNameOrIPAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to specify the RADIUS Server host name or
IP Address."
::= { oriRADIUSSvrTableEntry 5 }
oriRADIUSSvrTableDestPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the RADIUS server authentication port -
the default value is 1812."
DEFVAL { 1812 }
::= { oriRADIUSSvrTableEntry 6 }
oriRADIUSSvrTableSharedSecret OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the shared secret between the RADIUS
server and client. This object should be treated as write-only
and returned as asterisks."
::= { oriRADIUSSvrTableEntry 7 }
oriRADIUSSvrTableResponseTime OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the time (in seconds) for which the
RADIUS client will wait, until another authentication request is
sent to the server."
DEFVAL { 3 }
::= { oriRADIUSSvrTableEntry 8 }
oriRADIUSSvrTableMaximumRetransmission OBJECT-TYPE
SYNTAX Integer32 (0..4)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the number of retransmissions of
authentication requests by the RADIUS Client to the Server."
DEFVAL { 3 }
::= { oriRADIUSSvrTableEntry 9 }
oriRADIUSSvrTableVLANID OBJECT-TYPE
SYNTAX VlanId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the VLAND ID that will be used to tag
RADIUS messages from the client to the server."
::= { oriRADIUSSvrTableEntry 10 }
oriRADIUSSvrTableMACAddressFormat OBJECT-TYPE
SYNTAX INTEGER
{
dashDelimited(1),
colonDelimited(2),
singleDashDelimited(3),
noDelimiter(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the MAC Address format that is to be
used for communication with the RADIUS Server.
Examples of MAC Address Format are:
- Dash Delimited: 00-11-22-AA-BB-CC
- Colon Delimited: 00:11:22:AA:BB:CC
- Single Dash Delimited: 001122-AABBCC
- No Delimiter: 001122AABBCC"
DEFVAL { dashDelimited }
::= { oriRADIUSSvrTableEntry 11 }
oriRADIUSSvrTableAuthorizationLifeTime OBJECT-TYPE
SYNTAX Integer32 (0|900..43200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the authorization lifetime for a certain
MAC based RADIUS authenticated client. A value of zero (0) means that
re-authorization is disabled. The units for this object is seconds."
DEFVAL { 0 }
::= { oriRADIUSSvrTableEntry 12 }
oriRADIUSSvrTableAccountingInactivityTimer OBJECT-TYPE
SYNTAX Integer32 (1..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter represents the client idle timeout in
minutes. Once this timer has expired an Accounting Stop request
is sent to the RADIUS Accounting Server."
DEFVAL { 5 }
::= { oriRADIUSSvrTableEntry 13 }
oriRADIUSSvrTableAccountingUpdateInterval OBJECT-TYPE
SYNTAX Integer32 (0|10..10080)
UNITS "minutes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to specify the interval in seconds at which
RADIUS accounting update messages will be sent. This object is defined
in minutes; a value of zero (0) disables the accouting updates."
::= { oriRADIUSSvrTableEntry 14 }
oriRADIUSSvrTableRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the status of the RADIUS Server profile."
::= { oriRADIUSSvrTableEntry 15 }
--=============================================================================
-- The RADIUS Authentication Client Statistics Table
--=============================================================================
oriRADIUSClientInvalidSvrAddress OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter represents the total number of RADIUS access-response
messages received from an unknown address since system startup."
::= { orinocoRADIUSSvrProfiles 2 }
oriRADIUSAuthClientStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriRADIUSAuthClientStatTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to store RADIUS Authentication Client Statistics
for the configured profiles."
::= { orinocoRADIUSSvrProfiles 3 }
oriRADIUSAuthClientStatTableEntry OBJECT-TYPE
SYNTAX OriRADIUSAuthClientStatTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry, primary and secondary/backup,
in the RADIUS Authentication Client Statistics table."
INDEX { oriRADIUSAuthClientStatTableIndex,
oriRADIUSAuthClientStatTablePrimaryOrSecondaryIndex }
::= { oriRADIUSAuthClientStatTable 1 }
OriRADIUSAuthClientStatTableEntry ::=
SEQUENCE
{
oriRADIUSAuthClientStatTableIndex Integer32,
oriRADIUSAuthClientStatTablePrimaryOrSecondaryIndex Integer32,
oriRADIUSAuthClientStatTableAccessRequests Counter32,
oriRADIUSAuthClientStatTableAccessRetransmissions Counter32,
oriRADIUSAuthClientStatTableAccessAccepts Counter32,
oriRADIUSAuthClientStatTableAccessRejects Counter32,
oriRADIUSAuthClientStatTableAccessChallenges Counter32,
oriRADIUSAuthClientStatTableMalformedAccessResponses Counter32,
oriRADIUSAuthClientStatTableBadAuthenticators Counter32,
oriRADIUSAuthClientStatTableTimeouts Counter32
}
oriRADIUSAuthClientStatTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as an index to the RADIUS Authentication Client
Statistics Table."
::= { oriRADIUSAuthClientStatTableEntry 1 }
oriRADIUSAuthClientStatTablePrimaryOrSecondaryIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as an secondary index to the RADIUS
Authentication Client Statistics Table, which is used to indicate
primary and secondary/backup server statistics."
::= { oriRADIUSAuthClientStatTableEntry 2 }
oriRADIUSAuthClientStatTableAccessRequests OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of RADIUS Access Requests
messages transmitted from the client to the server since client
startup."
::= { oriRADIUSAuthClientStatTableEntry 3 }
oriRADIUSAuthClientStatTableAccessRetransmissions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of RADIUS Access Requests
retransmitted by the client to the server since system startup."
::= { oriRADIUSAuthClientStatTableEntry 4 }
oriRADIUSAuthClientStatTableAccessAccepts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of RADIUS Access Accept messages
received since system startup."
::= { oriRADIUSAuthClientStatTableEntry 5 }
oriRADIUSAuthClientStatTableAccessChallenges OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of RADIUS Access Challenges
messages received since system startup."
::= { oriRADIUSAuthClientStatTableEntry 6 }
oriRADIUSAuthClientStatTableAccessRejects OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of RADIUS Access Rejects
messages received since system startup."
::= { oriRADIUSAuthClientStatTableEntry 7 }
oriRADIUSAuthClientStatTableMalformedAccessResponses OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of malformed RADIUS Access
Response messages received since system startup."
::= { oriRADIUSAuthClientStatTableEntry 8 }
oriRADIUSAuthClientStatTableBadAuthenticators OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of malformed RADIUS Access
Response messages containing invalid authenticators received since
system startup."
::= { oriRADIUSAuthClientStatTableEntry 9 }
oriRADIUSAuthClientStatTableTimeouts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the total number of timeouts for RADIUS
Access Request messages since system startup."
::= { oriRADIUSAuthClientStatTableEntry 10 }
--=============================================================================
-- The RADIUS Accounting Client Statistics Table
--=============================================================================
oriRADIUSAcctClientStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriRADIUSAcctClientStatTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to store RADIUS Accounting Client Statistics
for the configured profiles."
::= { orinocoRADIUSSvrProfiles 4 }
oriRADIUSAcctClientStatTableEntry OBJECT-TYPE
SYNTAX OriRADIUSAcctClientStatTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry, primary and secondary/backup,
in the RADIUS Accounting Client Statistics table."
INDEX { oriRADIUSAcctClientStatTableIndex,
oriRADIUSAcctClientStatTablePrimaryOrSecondaryIndex }
::= { oriRADIUSAcctClientStatTable 1 }
OriRADIUSAcctClientStatTableEntry ::=
SEQUENCE
{
oriRADIUSAcctClientStatTableIndex Integer32,
oriRADIUSAcctClientStatTablePrimaryOrSecondaryIndex Integer32,
oriRADIUSAcctClientStatTableAccountingRequests Counter32,
oriRADIUSAcctClientStatTableAccountingRetransmissions Counter32,
oriRADIUSAcctClientStatTableAccountingResponses Counter32,
oriRADIUSAcctClientStatTableBadAuthenticators Counter32
}
oriRADIUSAcctClientStatTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as an index to the RADIUS Accounting Client
Statistics Table."
::= { oriRADIUSAcctClientStatTableEntry 1 }
oriRADIUSAcctClientStatTablePrimaryOrSecondaryIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as an secondary index to the RADIUS
Accounting Client Statistics Table, which is used to indicate
primary and secondary/backup server statistics."
::= { oriRADIUSAcctClientStatTableEntry 2 }
oriRADIUSAcctClientStatTableAccountingRequests OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of RADIUS Accounting Requests
messages transmitted from the client to the server since client
startup."
::= { oriRADIUSAcctClientStatTableEntry 3 }
oriRADIUSAcctClientStatTableAccountingRetransmissions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of RADIUS Accounting Requests
retransmitted by the client to the server since system startup."
::= { oriRADIUSAcctClientStatTableEntry 4 }
oriRADIUSAcctClientStatTableAccountingResponses OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of RADIUS Accounting Response
messages received since system startup."
::= { oriRADIUSAcctClientStatTableEntry 5 }
oriRADIUSAcctClientStatTableBadAuthenticators OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of malformed RADIUS Access
Response messages containing invalid authenticators received since
system startup."
::= { oriRADIUSAcctClientStatTableEntry 6 }
--=============================================================================
-- The Telnet Group: orinocoTelnet
--=============================================================================
oriTelnetSessions OBJECT-TYPE
SYNTAX Integer32 (0..5)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object is used to enable or disable telnet access and
to specify the maximum number of active telnet sessions. When this
object is set to 0, telnet access is disabled. When this object
is set to something greater than 0, then it specifies the maximum
number of active telnet sessions. This object has been deprecated."
DEFVAL { 1 }
::= { orinocoTelnet 1 }
oriTelnetPassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the password to access the device via the telnet
interface. This object should be treated as write-only and
returned as asterisks."
DEFVAL { "public" }
::= { orinocoTelnet 2 }
oriTelnetPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the TCP/IP port for which the telnet
daemon/server will be accessible."
DEFVAL { 23 }
::= { orinocoTelnet 3 }
oriTelnetLoginTimeout OBJECT-TYPE
SYNTAX Integer32 (30..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the telnet login timeout in seconds."
DEFVAL { 60 }
::= { orinocoTelnet 4 }
oriTelnetIdleTimeout OBJECT-TYPE
SYNTAX Integer32 (60..36000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the telnet inactivity/idle timeout in
seconds."
DEFVAL { 900 }
::= { orinocoTelnet 5 }
oriTelnetInterfaceBitmask OBJECT-TYPE
SYNTAX InterfaceBitmask
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to control interface access for telnet based
management."
::= { orinocoTelnet 6 }
oriTelnetSSHStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable CLI access configuration
using secure shell."
DEFVAL { disable }
::= { orinocoTelnet 7 }
oriTelnetSSHHostKeyStatus OBJECT-TYPE
SYNTAX INTEGER
{
create(1),
delete(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used create or delete the SSH Public Host key of the
device."
::= { orinocoTelnet 8 }
oriTelnetSSHFingerPrint OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the fingerprint of the SSH Public Host key stored
on the device."
::= { orinocoTelnet 9 }
oriTelnetRADIUSAccessControl OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable/disable RADIUS Based Authentication for
telnet based management."
DEFVAL { disable }
::= { orinocoTelnet 10 }
--=============================================================================
-- The TFTP Group: orinocoTFTP
--=============================================================================
oriTFTPServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the IP address of the TFTP server."
DEFVAL { '0a000002'H }
::= { orinocoTFTP 1 }
oriTFTPFileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the filename to upload or download to the
TFTP server."
DEFVAL { "Filename" }
::= { orinocoTFTP 2 }
oriTFTPFileType OBJECT-TYPE
SYNTAX INTEGER
{
config(1),
image(2),
bootloader(3),
license(4),
certificate(5),
privatekey(6),
sshHostPublicKey(7),
sshHostPrivateKey(8),
cliBatchFile(9),
cliBatchLog(10),
templog(11),
eventlog(12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for the device to know what type of file is
being uploaded or downloaded."
::= { orinocoTFTP 3 }
oriTFTPOperation OBJECT-TYPE
SYNTAX INTEGER
{
upload(1),
download(2),
downloadAndReboot(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the TFTP operation to be executed. The
upload function shall transfer the specified file from the
device to the TFTP server. The download function shall transfer
the specified file from the TFTP server to the device. The
download and reboot option, will perform the download and then
reboot the device."
::= { orinocoTFTP 4 }
oriTFTPFileMode OBJECT-TYPE
SYNTAX INTEGER
{
ascii(1),
bin(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This objects represents the file transfer mode for the TFTP
protocol."
::= { orinocoTFTP 5 }
oriTFTPOperationStatus OBJECT-TYPE
SYNTAX INTEGER
{
idle(1),
inProgress(2),
successful(3),
failure(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the TFTP operation status. When a TFTP
operation is idle (not in progress) this object will be set to 1.
When a TFTP operation is in progress this object will be set to 2.
When a TFTP operation has been successful this object will be set
to 3. When a TFTP operation has failed this object will be set
to 4."
::= { orinocoTFTP 6 }
oriTFTPAutoConfigStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This objects is used to enable/disable the Auto Configuration feature.
This feature allows for a configuration file to be downloaded from
a TFTP server so the AP can be configured via a config file."
::= { orinocoTFTP 7 }
oriTFTPAutoConfigFilename OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the name of the configuration file
to be downloaded using the Auto Configuration feature. This filename
can be configured directly via the end user or can be retrieved in the
DHCP response message when the AP is configured for dynamic IP address
assignment type."
::= { orinocoTFTP 8 }
oriTFTPAutoConfigServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the TFTP server IP Address. This
object can be configured directly via the end user or can be retrieved
in the DHCP response message when the AP is configured for dynamic IP
address assignment type."
::= { orinocoTFTP 9 }
oriTFTPDowngrade OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
rel201(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"On selection of this option, the software will downgrade the
configuration file to the specified release from the current
release"
DEFVAL { none }
::= { orinocoTFTP 10 }
--=============================================================================
-- The Serial Group: orinocoSerial
--=============================================================================
oriSerialBaudRate OBJECT-TYPE
SYNTAX INTEGER
{
baud2400(1),
baud4800(2),
baud9600(3),
baud19200(4),
baud38400(5),
baud57600(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the baud rate for the serial interface -
the default value is 9600."
DEFVAL { baud9600 }
::= { orinocoSerial 1 }
oriSerialDataBits OBJECT-TYPE
SYNTAX Integer32 (4..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the serial interface data bits - the
default value is 8."
DEFVAL { 8 }
::= { orinocoSerial 2 }
oriSerialParity OBJECT-TYPE
SYNTAX INTEGER
{
even(1),
odd(2),
none(3),
mark(4),
space(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used for the serial interface parity check - the
default value is none."
DEFVAL { none }
::= { orinocoSerial 3 }
oriSerialStopBits OBJECT-TYPE
SYNTAX INTEGER
{
bit1(1),
bit1dot5(2),
bit2(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the serial interface stop bits - the
default value is 1."
DEFVAL { bit1 }
::= { orinocoSerial 4 }
oriSerialFlowControl OBJECT-TYPE
SYNTAX INTEGER
{
xonxoff(1),
none(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for the serial interface flow control - the
default value is none."
DEFVAL { none }
::= { orinocoSerial 5 }
--=============================================================================
-- The IAPP Group: orinocoIAPP
--=============================================================================
oriIAPPStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the IAPP feature."
DEFVAL { enable }
::= { orinocoIAPP 1 }
oriIAPPPeriodicAnnounceInterval OBJECT-TYPE
SYNTAX INTEGER
{
eighty(80),
oneHundredTwenty(120),
oneHundredSixty(160),
twoHundred(200)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents interval in seconds for performing an
IAPP announce operation by the device."
DEFVAL { oneHundredTwenty }
::= { orinocoIAPP 2 }
oriIAPPAnnounceResponseTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the amount of time in seconds the
device waits to send an IAPP announce response after an announce
request message is sent."
::= { orinocoIAPP 3 }
oriIAPPHandoverTimeout OBJECT-TYPE
SYNTAX INTEGER
{
fourHundredTen(410),
fiveHundredTwelve(512),
sixHundredFourteen(614),
sevenHundredSeventeen(717),
eightHundredNineteen(819)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the time in milliseconds the device
waits before it resends a handover response message. This
object is originally given in kuseconds, but has been converted
to milliseconds."
DEFVAL { fiveHundredTwelve }
::= { orinocoIAPP 4 }
oriIAPPMaximumHandoverRetransmissions OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the maximum amount of retransmission sent
by the device for a handover request message."
DEFVAL { 4 }
::= { orinocoIAPP 5 }
oriIAPPAnnounceRequestSent OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the total number of IAPP Announce
Request Messages sent since system startup."
::= { orinocoIAPP 6 }
oriIAPPAnnounceRequestReceived OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the total number of IAPP Announce
Request Messages received since system startup."
::= { orinocoIAPP 7 }
oriIAPPAnnounceResponseSent OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the total number of IAPP Announce
Response Messages sent since system startup."
::= { orinocoIAPP 8 }
oriIAPPAnnounceResponseReceived OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the total number of IAPP Announce
Response Messages received since system startup."
::= { orinocoIAPP 9 }
oriIAPPHandoverRequestSent OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the total number of IAPP Handover
Request messages sent since system startup."
::= { orinocoIAPP 10 }
oriIAPPHandoverRequestReceived OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the total number of IAPP Handover
Request messages received since system startup."
::= { orinocoIAPP 11 }
oriIAPPHandoverRequestRetransmissions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the total number of IAPP Handover
Request retransmissions since system startup."
::= { orinocoIAPP 12 }
oriIAPPHandoverResponseSent OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the total number of IAPP Handover
Response messages sent since system startup."
::= { orinocoIAPP 13 }
oriIAPPHandoverResponseReceived OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the total number of IAPP Handover
Response messages received since system startup."
::= { orinocoIAPP 14 }
oriIAPPPDUsDropped OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the total number of IAPP packets dropped
due to erroneous information within the packet since system
startup."
::= { orinocoIAPP 15 }
oriIAPPRoamingClients OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the total number of client that have
roamed from one device to another. This parameter is per device
and not a total counter of all the roaming clients for all devices
on the network."
::= { orinocoIAPP 16 }
oriIAPPMACIPTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriIAPPMACIPTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains a list of devices on the network that support
IAPP and have the feature enabled."
::= { orinocoIAPP 21 }
oriIAPPMACIPTableEntry OBJECT-TYPE
SYNTAX OriIAPPMACIPTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the IAPP table, which
essentially is a device that supports IAPP and has the feature
enabled."
INDEX { oriIAPPMACIPTableIndex }
::= { oriIAPPMACIPTable 1 }
OriIAPPMACIPTableEntry ::=
SEQUENCE
{
oriIAPPMACIPTableIndex Integer32,
oriIAPPMACIPTableSystemName DisplayString,
oriIAPPMACIPTableIPAddress IpAddress,
oriIAPPMACIPTableBSSID PhysAddress,
oriIAPPMACIPTableESSID DisplayString
}
oriIAPPMACIPTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as the index for the IAPP MAC-IP table."
::= { oriIAPPMACIPTableEntry 1 }
oriIAPPMACIPTableSystemName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the System Name of the IAPP enabled
device."
::= { oriIAPPMACIPTableEntry 2 }
oriIAPPMACIPTableIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the IP Address of the IAPP enabled device."
::= { oriIAPPMACIPTableEntry 3 }
oriIAPPMACIPTableBSSID OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the BSSID (MAC address of wireless
interface) of the IAPP enabled device."
::= { oriIAPPMACIPTableEntry 4 }
oriIAPPMACIPTableESSID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the ESSID (network name) of the IAPP
enabled device."
::= { oriIAPPMACIPTableEntry 5 }
oriIAPPSendAnnounceRequestOnStart OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to determine whether to send announce request
on start."
DEFVAL { enable }
::= { orinocoIAPP 22 }
--=============================================================================
-- The Link Test Group: orinocoLinkTest
--=============================================================================
oriLinkTestTimeOut OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object determines the time (in seconds) that a
link test will continue without any SNMP requests for a Link Test
Table entry. When the time expires the Link Test Table is
cleared."
DEFVAL { 300 }
::= { orinocoLinkTest 1 }
oriLinkTestInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the interval (in milliseconds) between
sending link test frames to a station."
DEFVAL { 200 }
::= { orinocoLinkTest 3 }
oriLinkTestExplore OBJECT-TYPE
SYNTAX INTEGER
{
tableTimedOut(1),
exploring(2),
exploreResultsAvailable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is set to 2, the device will send out an explore
request on all 802.11 interfaces and from the results build the
Link Test table. This table is valid only while this object is
set to 3."
::= { orinocoLinkTest 4 }
oriLinkTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriLinkTestTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the information for the stations currently
associated with the access point."
::= { orinocoLinkTest 5 }
oriLinkTestTableEntry OBJECT-TYPE
SYNTAX OriLinkTestTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the entry in the Remote Link Test table."
INDEX { oriLinkTestTableIndex }
::= { oriLinkTestTable 1 }
OriLinkTestTableEntry ::=
SEQUENCE
{
oriLinkTestTableIndex Integer32,
oriLinkTestInProgress INTEGER,
oriLinkTestStationName DisplayString,
oriLinkTestMACAddress PhysAddress,
oriLinkTestStationProfile Integer32,
oriLinkTestOurCurSignalLevel Integer32,
oriLinkTestOurCurNoiseLevel Integer32,
oriLinkTestOurCurSNR Integer32,
oriLinkTestOurMinSignalLevel Integer32,
oriLinkTestOurMinNoiseLevel Integer32,
oriLinkTestOurMinSNR Integer32,
oriLinkTestOurMaxSignalLevel Integer32,
oriLinkTestOurMaxNoiseLevel Integer32,
oriLinkTestOurMaxSNR Integer32,
oriLinkTestOurLowFrameCount Integer32,
oriLinkTestOurStandardFrameCount Integer32,
oriLinkTestOurMediumFrameCount Integer32,
oriLinkTestOurHighFrameCount Integer32,
oriLinkTestHisCurSignalLevel Integer32,
oriLinkTestHisCurNoiseLevel Integer32,
oriLinkTestHisCurSNR Integer32,
oriLinkTestHisMinSignalLevel Integer32,
oriLinkTestHisMinNoiseLevel Integer32,
oriLinkTestHisMinSNR Integer32,
oriLinkTestHisMaxSignalLevel Integer32,
oriLinkTestHisMaxNoiseLevel Integer32,
oriLinkTestHisMaxSNR Integer32,
oriLinkTestHisLowFrameCount Integer32,
oriLinkTestHisStandardFrameCount Integer32,
oriLinkTestHisMediumFrameCount Integer32,
oriLinkTestHisHighFrameCount Integer32,
oriLinkTestInterface DisplayString,
oriLinkTestRadioType DisplayString
}
oriLinkTestTableIndex OBJECT-TYPE
SYNTAX Integer32 (0..500)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents a unique value for each station. The
value for each station must remain constant at least from one
explore to the next."
::= { oriLinkTestTableEntry 1 }
oriLinkTestInProgress OBJECT-TYPE
SYNTAX INTEGER
{
noLinkTestInProgress(1),
linkTestIinProgress(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is set to 2 the device will initiate a link test
sequence with this station."
::= { oriLinkTestTableEntry 2 }
oriLinkTestStationName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the name of the station whom which the
link test is being performed."
::= { oriLinkTestTableEntry 3 }
oriLinkTestMACAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the MAC address that will be mapped to
the IP Address of the station."
::= { oriLinkTestTableEntry 4 }
oriLinkTestStationProfile OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the profile/capabilities for this station."
::= { oriLinkTestTableEntry 5 }
oriLinkTestOurCurSignalLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current signal level (in dB) for the link test from this
station. This object indicates the running average of the local
signal level using the algorithm (3/4*oldvalue + 1/4*newvalue)."
::= { oriLinkTestTableEntry 6 }
oriLinkTestOurCurNoiseLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current noise level (in dB) for the link test to this station.
This object indicates the running average of the local noise
level."
::= { oriLinkTestTableEntry 7 }
oriLinkTestOurCurSNR OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current signal to noise ratio for the link test to this
station."
::= { oriLinkTestTableEntry 8 }
oriLinkTestOurMinSignalLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum signal level during the link test to this station."
::= { oriLinkTestTableEntry 9 }
oriLinkTestOurMinNoiseLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum noise level during the link test to this station."
::= { oriLinkTestTableEntry 10 }
oriLinkTestOurMinSNR OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum signal to noise ratio during the link test to this
station."
::= { oriLinkTestTableEntry 11 }
oriLinkTestOurMaxSignalLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum signal level during the link test to this station."
::= { oriLinkTestTableEntry 12 }
oriLinkTestOurMaxNoiseLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum noise level during the link test to this station."
::= { oriLinkTestTableEntry 13 }
oriLinkTestOurMaxSNR OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum signal to noise ratio during the link test to this
station."
::= { oriLinkTestTableEntry 14 }
oriLinkTestOurLowFrameCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames sent at 1 Mbit/s speed during the link
test to this station."
::= { oriLinkTestTableEntry 15 }
oriLinkTestOurStandardFrameCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames sent at 2 Mbit/s speed during the link
test to this station."
::= { oriLinkTestTableEntry 16 }
oriLinkTestOurMediumFrameCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames sent at 5.5 Mbit/s (for Turbo-8, it is
5 Mbit/s) speed during the link test to this station."
::= { oriLinkTestTableEntry 17 }
oriLinkTestOurHighFrameCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames sent at 11 Mbit/s (for Turbo-8, it is
8 Mbit/s) speed during the link test to this station."
::= { oriLinkTestTableEntry 18 }
oriLinkTestHisCurSignalLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current signal level for the link test to the remote station
or access point."
::= { oriLinkTestTableEntry 19 }
oriLinkTestHisCurNoiseLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current noise level for the link test to the remote station
or access point device."
::= { oriLinkTestTableEntry 20 }
oriLinkTestHisCurSNR OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current signal to noise ratio for the link test to the remote
station or access point device."
::= { oriLinkTestTableEntry 21 }
oriLinkTestHisMinSignalLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum signal level during the link test to the remote station
or access point device."
::= { oriLinkTestTableEntry 22 }
oriLinkTestHisMinNoiseLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum noise level during the link test to the remote station
or access point device."
::= { oriLinkTestTableEntry 23 }
oriLinkTestHisMinSNR OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum signal to noise ratio during the link test to the
remote station or access point device."
::= { oriLinkTestTableEntry 24 }
oriLinkTestHisMaxSignalLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum signal level during the link test to the remote
station or access point device."
::= { oriLinkTestTableEntry 25 }
oriLinkTestHisMaxNoiseLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum noise level during the link test to the remote station
or access point device."
::= { oriLinkTestTableEntry 26 }
oriLinkTestHisMaxSNR OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum signal to noise ratio during the link test to the
remote station or access point device."
::= { oriLinkTestTableEntry 27 }
oriLinkTestHisLowFrameCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames sent at 1 Mbit/s speed during the link
test to the remote station or access point device."
::= { oriLinkTestTableEntry 28 }
oriLinkTestHisStandardFrameCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames sent at 2 Mbit/s speed during the link
test to the remote station or access point device."
::= { oriLinkTestTableEntry 29 }
oriLinkTestHisMediumFrameCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames sent at 5.5 Mbit/s (for Turbo-8, it is
5 Mbit/s) speed during the link test to the remote station or
access point device."
::= { oriLinkTestTableEntry 30 }
oriLinkTestHisHighFrameCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames sent at 11 Mbit/s (for Turbo-8, it is
5 Mbit/s) speed during the link test to the remote station or
access point device."
::= { oriLinkTestTableEntry 31 }
oriLinkTestInterface OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the wireless interface number to which the
Client has sent the Explore Response Message."
::= { oriLinkTestTableEntry 32 }
oriLinkTestRadioType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Wireless Standard for example IEEE 802.11, 802.11b, 802.11a, or
802.11g being used by the remote station."
::= { oriLinkTestTableEntry 33 }
oriLinkTestDataRateTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriLinkTestDataRateTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains counters for the data rates for the stations
currently associated to the access point."
::= { orinocoLinkTest 6 }
oriLinkTestDataRateTableEntry OBJECT-TYPE
SYNTAX OriLinkTestDataRateTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the entry in the Remote Link Test data
rate counter table."
INDEX { oriLinkTestTableIndex, oriLinkTestDataRateTableIndex }
::= { oriLinkTestDataRateTable 1 }
OriLinkTestDataRateTableEntry ::=
SEQUENCE
{
oriLinkTestDataRateTableIndex Integer32,
oriLinkTestDataRateTableRemoteCount Counter32,
oriLinkTestDataRateTableLocalCount Counter32
}
oriLinkTestDataRateTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the second index to the Link Test Data Rate Counter
Table. The data rates negotiated by the access point and client
station will represent an index into this table. The data rates are
defined in units of 500 Kbps."
::= { oriLinkTestDataRateTableEntry 1 }
oriLinkTestDataRateTableRemoteCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames sent at the data rate value of the index
during the link test to the remote station or access point device."
::= { oriLinkTestDataRateTableEntry 2 }
oriLinkTestDataRateTableLocalCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames sent at the data rate value of the index
(oriLinkTestDataRateTableindex) during the link test to the client
station indenfied by the index (oriLinkTestTableIndex)."
::= { oriLinkTestDataRateTableEntry 3 }
--=============================================================================
-- The Link Integrity Group: orinocoLinkInt
--=============================================================================
oriLinkIntStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the link integrity
functionality."
::= { orinocoLinkInt 1 }
oriLinkIntPollInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to set the poll interval (in milliseconds)
for the link integrity check. The valid values for this objects
are multiples of 500 milliseconds, a value of zero is not
supported."
DEFVAL { 500 }
::= { orinocoLinkInt 2 }
oriLinkIntPollRetransmissions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to set the number of retransmissions for
the link integrity check."
::= { orinocoLinkInt 3 }
oriLinkIntTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriLinkIntTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the target IP addresses in order to perform
the link integrity check. This table is limited to 5 entries."
::= { orinocoLinkInt 4 }
oriLinkIntTableEntry OBJECT-TYPE
SYNTAX OriLinkIntTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object identifies the entry in the link integrity target
table."
INDEX { oriLinkIntTableIndex }
::= { oriLinkIntTable 1 }
OriLinkIntTableEntry ::=
SEQUENCE
{
oriLinkIntTableIndex Integer32,
oriLinkIntTableTargetIPAddress IpAddress,
oriLinkIntTableComment DisplayString,
oriLinkIntTableEntryStatus INTEGER
}
oriLinkIntTableIndex OBJECT-TYPE
SYNTAX Integer32 (0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as an index for the link integrity target
table."
::= { oriLinkIntTableEntry 1 }
oriLinkIntTableTargetIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the IP address of the target machine for
the link integrity check."
::= { oriLinkIntTableEntry 2 }
oriLinkIntTableComment OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used as an optional comment associated to the
link integrity table entry."
::= { oriLinkIntTableEntry 3 }
oriLinkIntTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable, disable, or delete an
entry in the link integrity table."
::= { oriLinkIntTableEntry 4 }
--=============================================================================
-- The Uplink Power Saving Devices Group: orinocoUPSD
--=============================================================================
oriUPSDGPRInterval OBJECT-TYPE
SYNTAX Integer32 (0..25)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to set the interval of GPR message (in 5ms step),
0 = disable GPR."
DEFVAL { 0 }
::= { orinocoUPSD 1 }
oriUPSDMaxActiveSU OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to set the maximum actived SU per AP."
DEFVAL { 32 }
::= { orinocoUPSD 2 }
oriUPSDE911Reserved OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to set the bandwidth allocated for E911calls."
DEFVAL { 16 }
::= { orinocoUPSD 3 }
oriUPSDRoamingReserved OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to set the bandwidth allocated for roaming SU."
DEFVAL { 16 }
::= { orinocoUPSD 4 }
--=============================================================================
-- The Quality of Service Group: orinocoQoS
--=============================================================================
oriQoSPolicyTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriQoSPolicyTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to configure Quality of Service policies to be used
in the Access Point."
::= { orinocoQoS 1 }
oriQoSPolicyTableEntry OBJECT-TYPE
SYNTAX OriQoSPolicyTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents entries in the QoS Policy Table."
INDEX { oriQoSPolicyTableIndex, oriQoSPolicyTableSecIndex }
::= { oriQoSPolicyTable 1 }
OriQoSPolicyTableEntry ::=
SEQUENCE
{
oriQoSPolicyTableIndex Integer32,
oriQoSPolicyTableSecIndex Integer32,
oriQoSPolicyName DisplayString32,
oriQoSPolicyType INTEGER,
oriQoSPolicyPriorityMapping Integer32,
oriQoSPolicyMarkingStatus ObjStatus,
oriQoSPolicyTableRowStatus RowStatus
}
oriQoSPolicyTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as the primary index to the QoS Policy Table."
::= { oriQoSPolicyTableEntry 1 }
oriQoSPolicyTableSecIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as the secondary index to the QoS Policy Table."
::= { oriQoSPolicyTableEntry 2 }
oriQoSPolicyName OBJECT-TYPE
SYNTAX DisplayString32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to specify a name for the QoS Policy."
::= { oriQoSPolicyTableEntry 3 }
oriQoSPolicyType OBJECT-TYPE
SYNTAX INTEGER
{
inboundLayer2(1),
inboundLayer3(2),
outboundLayer2(3),
outboundLayer3(4),
spectralink(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to specify the QoS policy type."
DEFVAL { inboundLayer2 }
::= { oriQoSPolicyTableEntry 4 }
oriQoSPolicyPriorityMapping OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the QoS priority mapping. The index
from either the QoS 802.1D to 802.1p mapping table or the index from
the 802.1D to IP DSCP mapping table should be specified depending on the
policy type. For Layer 2 polices, an index from the QoS 802.1D to
802.1p mapping table should be specified. For Layer 3 policies, an
index from the QoS 802.1D to IP DSCP mapping table should be specified.
If a spectralink policy is configured, then this object is not used."
::= { oriQoSPolicyTableEntry 5 }
oriQoSPolicyMarkingStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable QoS markings."
::= { oriQoSPolicyTableEntry 6 }
oriQoSPolicyTableRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object is used to configure the QoS Policy Table row status."
::= { oriQoSPolicyTableEntry 7 }
oriQoSDot1DToDot1pMappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriQoSDot1DToDot1pMappingTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to configure Quality of Service mappings between
802.1D and 802.1p priorities."
::= { orinocoQoS 2 }
oriQoSDot1DToDot1pMappingTableEntry OBJECT-TYPE
SYNTAX OriQoSDot1DToDot1pMappingTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents entries in the QoS 802.1D to 802.1p Mapping
Table."
INDEX { oriQoSDot1DToDot1pMappingTableIndex, oriQoSDot1dPriority }
::= { oriQoSDot1DToDot1pMappingTable 1 }
OriQoSDot1DToDot1pMappingTableEntry ::=
SEQUENCE
{
oriQoSDot1DToDot1pMappingTableIndex Integer32,
oriQoSDot1dPriority Integer32,
oriQoSDot1pPriority Integer32,
oriQoSDot1DToDot1pMappingTableRowStatus RowStatus
}
oriQoSDot1DToDot1pMappingTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as the primary index to the QoS 802.1D to 802.1p
mapping table."
::= { oriQoSDot1DToDot1pMappingTableEntry 1 }
oriQoSDot1dPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to specify the 802.1d priority and is used as
the secondary index to the 802.1D to 802.1p mapping table."
::= { oriQoSDot1DToDot1pMappingTableEntry 2 }
oriQoSDot1pPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to specify the 802.1D priority to be mapped to a
802.1p priority."
::= { oriQoSDot1DToDot1pMappingTableEntry 3 }
oriQoSDot1DToDot1pMappingTableRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object is used to configure the QoS 802.1D to 802.1p mapping table
row status."
::= { oriQoSDot1DToDot1pMappingTableEntry 4 }
oriQoSDot1DToIPDSCPMappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriQoSDot1DToIPDSCPMappingTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to configure Quality of Service mappings between
802.1D to IP DSCP priorities."
::= { orinocoQoS 3 }
oriQoSDot1DToIPDSCPMappingTableEntry OBJECT-TYPE
SYNTAX OriQoSDot1DToIPDSCPMappingTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents entries in the 802.1D to IP DSCP Mapping
Table."
INDEX { oriQoSDot1DToIPDSCPMappingTableIndex,
oriQoSDot1DToIPDSCPPriority }
::= { oriQoSDot1DToIPDSCPMappingTable 1 }
OriQoSDot1DToIPDSCPMappingTableEntry ::=
SEQUENCE
{
oriQoSDot1DToIPDSCPMappingTableIndex Integer32,
oriQoSDot1DToIPDSCPPriority Integer32,
oriQoSIPDSCPLowerLimit Integer32,
oriQoSIPDSCPUpperLimit Integer32,
oriQoSDot1DToIPDSCPMappingTableRowStatus RowStatus
}
oriQoSDot1DToIPDSCPMappingTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as the primary index to the 802.1D to IP DSCP
mapping table."
::= { oriQoSDot1DToIPDSCPMappingTableEntry 1 }
oriQoSDot1DToIPDSCPPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to specify the 802.1D priority and is used as
the secondary index to the 802.1D to IP DSCP mapping table."
::= { oriQoSDot1DToIPDSCPMappingTableEntry 2 }
oriQoSIPDSCPLowerLimit OBJECT-TYPE
SYNTAX Integer32 (0..62)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to specify IP DSCP lower limit."
DEFVAL { 0 }
::= { oriQoSDot1DToIPDSCPMappingTableEntry 3 }
oriQoSIPDSCPUpperLimit OBJECT-TYPE
SYNTAX Integer32 (1..63)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to specify IP DSCP upper limit."
DEFVAL { 1 }
::= { oriQoSDot1DToIPDSCPMappingTableEntry 4 }
oriQoSDot1DToIPDSCPMappingTableRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object is used to configure the 802.1D to IP DSCP mapping
table row status."
::= { oriQoSDot1DToIPDSCPMappingTableEntry 5 }
--=============================================================================
-- The DHCP Group: orinocoDHCP
--=============================================================================
--=============================================================================
-- The DHCP Server Subgroup: orinocoDHCPServer
--=============================================================================
oriDHCPServerStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if the DHCP server is enabled or disabled
in the device."
::= { orinocoDHCPServer 1 }
oriDHCPServerIPPoolTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriDHCPServerIPPoolTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the pools of IP Addresses that the DHCP server
will assign to the DHCP clients. This table is limited to
20."
::= { orinocoDHCPServer 2 }
oriDHCPServerIPPoolTableEntry OBJECT-TYPE
SYNTAX OriDHCPServerIPPoolTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents entries in the DHCP IP Address Pool Table."
INDEX { oriDHCPServerIPPoolTableIndex }
::= { oriDHCPServerIPPoolTable 1 }
OriDHCPServerIPPoolTableEntry ::=
SEQUENCE
{
oriDHCPServerIPPoolTableIndex Integer32,
oriDHCPServerIPPoolTableStartIPAddress IpAddress,
oriDHCPServerIPPoolTableEndIPAddress IpAddress,
oriDHCPServerIPPoolTableWidth Integer32,
oriDHCPServerIPPoolTableDefaultLeaseTime Integer32,
oriDHCPServerIPPoolTableMaximumLeaseTime Integer32,
oriDHCPServerIPPoolTableComment DisplayString,
oriDHCPServerIPPoolTableEntryStatus INTEGER
}
oriDHCPServerIPPoolTableIndex OBJECT-TYPE
SYNTAX Integer32 (1..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as the index for the IP Address Pool table."
::= { oriDHCPServerIPPoolTableEntry 1 }
oriDHCPServerIPPoolTableStartIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the start IP address for this DHCP IP
Address IP Pool Table entry."
::= { oriDHCPServerIPPoolTableEntry 2 }
oriDHCPServerIPPoolTableEndIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the end IP address for this DHCP IP
Address IP Pool Table entry."
::= { oriDHCPServerIPPoolTableEntry 3 }
oriDHCPServerIPPoolTableWidth OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the width or number of IP Address in the
DHCP IP Address Pool table entry."
::= { oriDHCPServerIPPoolTableEntry 4 }
oriDHCPServerIPPoolTableDefaultLeaseTime OBJECT-TYPE
SYNTAX Integer32 (3600..86400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the default lease time, in seconds, for
the IP address assigned by the DHCP server to the DHCP client."
::= { oriDHCPServerIPPoolTableEntry 5 }
oriDHCPServerIPPoolTableMaximumLeaseTime OBJECT-TYPE
SYNTAX Integer32 (3600..86400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the maximum lease time in seconds for
the IP address assigned by the DHCP server to the DHCP client."
::= { oriDHCPServerIPPoolTableEntry 6 }
oriDHCPServerIPPoolTableComment OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents an optional comment for this table entry."
::= { oriDHCPServerIPPoolTableEntry 7 }
oriDHCPServerIPPoolTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object indicates the status of the DHCP IP Address Pool
Table entry."
::= { oriDHCPServerIPPoolTableEntry 8 }
oriDHCPServerDefaultGatewayIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the IP Address of the gateway or router
that the DHCP Server will assign to the DHCP client."
::= { orinocoDHCPServer 3 }
oriDHCPServerSubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the subnet mask to be provided to
DHCP clients. This object is the same as the subnet mask for
the device."
::= { orinocoDHCPServer 4 }
oriDHCPServerNumIPPoolTableEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of entries in the DHCP IP
Address Pool Table."
::= { orinocoDHCPServer 5 }
oriDHCPServerPrimaryDNSIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the primary DNS Server IP Address to be
assinged to a DHCP Client."
::= { orinocoDHCPServer 6 }
oriDHCPServerSecondaryDNSIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the secondary DNS Server IP Address to be
assinged to a DHCP Client."
::= { orinocoDHCPServer 7 }
--=============================================================================
-- The DHCP Client Subgroup: orinocoDHCPClient
--=============================================================================
oriDHCPClientID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the DHCP client ID."
::= { orinocoDHCPClient 1 }
oriDHCPClientInterfaceBitmask OBJECT-TYPE
SYNTAX InterfaceBitmask
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates to which interface a DHCP Request
in sent when the unit is in routing mode"
::= { orinocoDHCPClient 2 }
--=============================================================================
-- The DHCP Relay Agent Subgroup: orinocoDHCPRelay
--=============================================================================
oriDHCPRelayStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable and disable the DHCP Relay
functionality."
DEFVAL { disable }
::= { orinocoDHCPRelay 1 }
oriDHCPRelayDHCPServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriDHCPRelayDHCPServerTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains a list of DHCP servers to which the
DHCP Agent will communicate with."
::= { orinocoDHCPRelay 2 }
oriDHCPRelayDHCPServerTableEntry OBJECT-TYPE
SYNTAX OriDHCPRelayDHCPServerTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents and entry in the DHCP Server table."
INDEX {oriDHCPRelayDHCPServerTableIndex }
::= { oriDHCPRelayDHCPServerTable 1 }
OriDHCPRelayDHCPServerTableEntry ::=
SEQUENCE
{
oriDHCPRelayDHCPServerTableIndex Integer32,
oriDHCPRelayDHCPServerTableIpAddress IpAddress,
oriDHCPRelayDHCPServerTableComment DisplayString,
oriDHCPRelayDHCPServerTableEntryStatus INTEGER
}
oriDHCPRelayDHCPServerTableIndex OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as the index to this table. This table is
limited to 10 entries."
::= { oriDHCPRelayDHCPServerTableEntry 1 }
oriDHCPRelayDHCPServerTableIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the IP address of the DHCP server
that shall receive DHCP requests from the device."
::= { oriDHCPRelayDHCPServerTableEntry 2 }
oriDHCPRelayDHCPServerTableComment OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents an optional comment in order to provide
additional information or a unique identifier for the DHCP server
(for example the server system name)."
::= { oriDHCPRelayDHCPServerTableEntry 3 }
oriDHCPRelayDHCPServerTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable, disable, delete or create an
entry in the DHCP Server Table."
DEFVAL {disable}
::= { oriDHCPRelayDHCPServerTableEntry 4 }
--=============================================================================
-- The HTTP Server Group: orinocoHTTP
--=============================================================================
oriHTTPInterfaceBitmask OBJECT-TYPE
SYNTAX InterfaceBitmask
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to control interface access for HTTP based
management."
::= { orinocoHTTP 1 }
oriHTTPPassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the login password in order to manage
the device via a standard web browser. This object should be
treated as write-only and returned as asterisks."
::= { orinocoHTTP 2 }
oriHTTPPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the TCP/IP port by which the HTTP server
will be accessible."
::= { orinocoHTTP 3 }
oriHTTPWebSitenameTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriHTTPWebSitenameTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to store the different website interfaces
stored in the device. Different interfaces can be used to
support multiple languages, user levels (novice, expert), etc."
::= { orinocoHTTP 4 }
oriHTTPWebSitenameTableEntry OBJECT-TYPE
SYNTAX OriHTTPWebSitenameTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry is the HTTP website name table."
INDEX { oriHTTPWebSitenameTableIndex }
::= { oriHTTPWebSitenameTable 1 }
OriHTTPWebSitenameTableEntry ::=
SEQUENCE
{
oriHTTPWebSitenameTableIndex Integer32,
oriHTTPWebSiteFilename DisplayString,
oriHTTPWebSiteLanguage DisplayString,
oriHTTPWebSiteDescription DisplayString,
oriHTTPWebSitenameTableStatus INTEGER
}
oriHTTPWebSitenameTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This objects represents the index to the website interface
table."
::= { oriHTTPWebSitenameTableEntry 1 }
oriHTTPWebSiteFilename OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the filename under which the website
interface is stored in the device."
::= { oriHTTPWebSitenameTableEntry 2 }
oriHTTPWebSiteLanguage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the language of the website interface."
::= { oriHTTPWebSitenameTableEntry 3 }
oriHTTPWebSiteDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides a description for the website interface."
::= { oriHTTPWebSitenameTableEntry 4 }
oriHTTPWebSitenameTableStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable, disable, or delete a website
interface file."
::= { oriHTTPWebSitenameTableEntry 5 }
oriHTTPRefreshDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for the automatic refresh delay for the
website pages."
::= { orinocoHTTP 5 }
oriHTTPHelpInformationLink OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the link in the web
interface for where help information can be retrieved."
::= { orinocoHTTP 6 }
oriHTTPSSLStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable SSL on HTTP based
management."
DEFVAL { disable }
::= { orinocoHTTP 7 }
oriHTTPSSLPassphrase OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to specify the SSL certificate
passphrase on HTTP based management. This object should
be treated as write-only and returned as asterisks."
::= { orinocoHTTP 8 }
oriHTTPSetupWizardStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the HTT setup wizard. The
user can manually disable this functionality or when the setup wizard
completes it process successfully it sets this object to disable."
DEFVAL { enable }
::= { orinocoHTTP 9 }
oriHTTPRADIUSAccessControl OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable/disable RADIUS Based Authentication
for HTTP based management."
DEFVAL { disable }
::= { orinocoHTTP 10 }
--=============================================================================
-- The WDS Group: orinocoWDS
--=============================================================================
oriWDSSetupTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriWDSSetupTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used in to configure the WDS feature in the device."
::= { orinocoWDS 1 }
oriWDSSetupTableEntry OBJECT-TYPE
SYNTAX OriWDSSetupTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the WDS table. Note this
table is index by ifIndex and WDS table index."
INDEX { ifIndex, oriWDSSetupTablePortIndex }
::= { oriWDSSetupTable 1 }
OriWDSSetupTableEntry ::=
SEQUENCE
{
oriWDSSetupTablePortIndex Integer32,
oriWDSSetupTableEntryStatus INTEGER,
oriWDSSetupTablePartnerMACAddress PhysAddress
}
oriWDSSetupTablePortIndex OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the WDS port number."
::= { oriWDSSetupTableEntry 1 }
oriWDSSetupTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable a WDS table entry (link)."
::= { oriWDSSetupTableEntry 2 }
oriWDSSetupTablePartnerMACAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the partner MAC address for a WDS table
entry (link)."
::= { oriWDSSetupTableEntry 3 }
oriWDSSecurityTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriWDSSecurityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used in to configure the WDS security modes for all
entries in the WDS table."
::= { orinocoWDS 2 }
oriWDSSecurityTableEntry OBJECT-TYPE
SYNTAX OriWDSSecurityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the WDS security table. Note this
table is index by ifIndex since the security configuration will apply
for all the WDS links per interface."
INDEX { ifIndex }
::= { oriWDSSecurityTable 1 }
OriWDSSecurityTableEntry ::=
SEQUENCE
{
oriWDSSecurityTableSecurityMode INTEGER,
oriWDSSecurityTableEncryptionKey0 WEPKeyType
}
oriWDSSecurityTableSecurityMode OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
wep(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the WDS security mode. Currently
the supported WDS security modes are none and wep."
::= { oriWDSSecurityTableEntry 1 }
oriWDSSecurityTableEncryptionKey0 OBJECT-TYPE
SYNTAX WEPKeyType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the WDS Encryption Key 0. When the WDS
security mode is configured to wep, this object must be configured to
a valid value. This object should be treated as write-only and
returned as asterisks."
::= { oriWDSSecurityTableEntry 2 }
--=============================================================================
-- The Trap Group: orinocoTrap
--=============================================================================
--=============================================================================
-- The Trap Variables: oriTrapVariable
--=============================================================================
oriTrapVariable OBJECT IDENTIFIER
::= { orinocoTrap 1 }
oriGenericTrapVariable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to provide additional information on traps."
::= { oriTrapVariable 1 }
oriTrapVarMACAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to store the MAC address of the device
that has sent a trap."
::= { oriTrapVariable 2 }
oriTrapVarTFTPIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to store the IP Address of the TFTP server."
::= { oriTrapVariable 3 }
oriTrapVarTFTPFilename OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to store the name of the file on which the
TFTP operation has occurred."
::= { oriTrapVariable 4 }
oriTrapVarTFTPOperation OBJECT-TYPE
SYNTAX INTEGER
{
upload(1),
download(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to store the TFTP operation that failed,
either download or upload."
::= { oriTrapVariable 5 }
oriTrapVarUnauthorizedManagerIPaddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to store the IP address of the unauthorized
manager that has attempted to manage the device."
::= { oriTrapVariable 6 }
oriTrapVarFailedAuthenticationType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This trap variable is used to specify the client authentication
method/type that failed. The authentication methods/types are
dependant on the device and can range from the following:
- MAC Access Control Table
- RADIUS MAC Authentication
- 802.1x Authentication specifying the EAP-Type
- WORP Mutual Authentication
- SSID Authorization Failure specifying the SSID
- VLAN ID Authorization Failure specifying the VLAN ID"
::= { oriTrapVariable 7 }
oriTrapVarUnAuthorizedManagerCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents a counter for the number of unauthorized
SNMP managers that have attempted to modify and/or view the devices
setup. When this number is incremented a trap should be sent out
notifying the trap host(s) that an unauthorized station has
attempted to configure or monitor the device the count should also
be sent out in the trap message."
::= { oriTrapVariable 8 }
oriTrapVarTaskSuspended OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to inform what task has been suspended
on the device."
::= { oriTrapVariable 9 }
oriTrapVarUnauthorizedClientMACAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to store the MAC Address of an
unauthorized client station."
::= { oriTrapVariable 17 }
oriTrapVarWirelessCard OBJECT-TYPE
SYNTAX INTEGER
{
pcCardA(1),
pcCardB(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to determine on which Wireless Card,
PC Card A or PC Card B, a wireless TRAP has occured on."
::= { oriTrapVariable 18 }
oriTrapVarInterface OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to store the interface number."
::= { oriTrapVariable 21 }
oriTrapVarBatchCLIFilename OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to store filename used for Batch CLI execution."
::= { oriTrapVariable 22 }
oriTrapVarBatchCLIMessage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to store message from Batch CLI execution."
::= { oriTrapVariable 23 }
oriTrapVarBatchCLILineNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to store line number of command executed in Batch
CLI."
::= { oriTrapVariable 24 }
oriTrapVarDHCPServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to store the DHCP Server IP Address from which
the access point has received an IP address as a result of the a DHCP
client request."
::= { oriTrapVariable 25 }
oriTrapVarIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is a trap variable/object to store an IP address."
::= { oriTrapVariable 26 }
oriTrapVarSubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is a trap variable/object to store a subnet mask."
::= { oriTrapVariable 27 }
oriTrapVarDefaultRouterIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is a trap variable/object to store a default router
or gateway IP address."
::= { oriTrapVariable 28 }
--=============================================================================
-- The Enable/Disable Trap Group Variables
--=============================================================================
oriConfigurationTrapsStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the configuration
related traps."
::= { oriTrapVariable 10 }
oriSecurityTrapsStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the security
related traps."
::= { oriTrapVariable 11 }
oriWirelessIfTrapsStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the wireless
interface/card related traps."
::= { oriTrapVariable 12 }
oriOperationalTrapsStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the operational
related traps."
::= { oriTrapVariable 13 }
oriFlashMemoryTrapsStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the flash memory
related traps."
::= { oriTrapVariable 14 }
oriTFTPTrapsStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the TFTP
related traps."
::= { oriTrapVariable 15 }
oriTrapsImageStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the Image
related traps."
::= { oriTrapVariable 16 }
oriADSLIfTrapsStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the ADSL
interface related traps."
::= { oriTrapVariable 19 }
oriWORPTrapsStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the WORP related traps."
::= { oriTrapVariable 20 }
--=============================================================================
-- The IP/ARP Group: orinocoIPARP
--=============================================================================
oriProxyARPStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable/disable the Proxy ARP functionality
in the device."
DEFVAL { enable }
::= { orinocoIPARP 1 }
oriIPARPFilteringStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable/disable the IP/ARP functionality
in the device."
DEFVAL { disable }
::= { orinocoIPARP 2 }
oriIPARPFilteringIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to specify the IP/ARP Filtering address
in the device."
::= { orinocoIPARP 3 }
oriIPARPFilteringSubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to specify the IP/ARP Subnet Mask
in the device."
::= { orinocoIPARP 4 }
--=============================================================================
-- The Spanning Tree Group: orinocoSpanningTree
--=============================================================================
oriSpanningTreeStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable/disable the spanning tree protocol
in the device."
DEFVAL { enable }
::= { orinocoSpanningTree 1 }
--=============================================================================
-- The Security Group: orinocoSecurity
--=============================================================================
oriSecurityConfiguration OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
dot1x(2),
mixedWepAnddot1x(3)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object represents the supported security configuration options.
This object has been deprecated."
DEFVAL { none }
::= { orinocoSecurity 1 }
oriSecurityEncryptionKeyLengthTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriSecurityEncryptionKeyLengthTableEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This table is used to specify the encryption key length for
the wireless interface(s). This table has been deprecated."
::= { orinocoSecurity 2 }
oriSecurityEncryptionKeyLengthTableEntry OBJECT-TYPE
SYNTAX OriSecurityEncryptionKeyLengthTableEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This object represents an entry in the encryption key
length table. This object has been deprecated."
INDEX { ifIndex }
::= { oriSecurityEncryptionKeyLengthTable 1 }
OriSecurityEncryptionKeyLengthTableEntry ::=
SEQUENCE
{
oriSecurityEncryptionKeyLength INTEGER
}
oriSecurityEncryptionKeyLength OBJECT-TYPE
SYNTAX INTEGER
{
sixtyFourBits(1),
oneHundredTwentyEightBits(2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object represents the encryption key length, the supported
key lengths are 64 bits (40 + 24 for IV), and 128 bits
(104 + 24 for IV). This object has been deprecated."
DEFVAL { sixtyFourBits }
::= { oriSecurityEncryptionKeyLengthTableEntry 1 }
oriSecurityRekeyingInterval OBJECT-TYPE
SYNTAX Integer32 (60..65535)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object represents the encryption rekeying interval in seconds.
This object has been deprecated."
::= { orinocoSecurity 3 }
--=============================================================================
-- The Rogue AP Detection Subgroup: orinocoRAD
--=============================================================================
oriRADStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows to enable or disable the RAD service in the
device."
DEFVAL { disable }
::= { orinocoRAD 1 }
oriRADInterval OBJECT-TYPE
SYNTAX Integer32 (15..1440)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to identify the interval at which the RAD feature
will initialize. The units of this object is minutes."
DEFVAL { 15 }
::= { orinocoRAD 2 }
oriRADInterfaceBitmask OBJECT-TYPE
SYNTAX InterfaceBitmask
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the interface(s) on which the RAD
feature will operate on."
::= { orinocoRAD 3 }
oriRADLastSuccessfulScanTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the number of seconds that have elapsed since the
last successful RAD scan since the AP has started up."
::= { orinocoRAD 4 }
oriRADAccessPointCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of access points that were
discovered since the last RAD scan."
::= { orinocoRAD 5 }
oriRADScanResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriRADScanResultsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to store the RAD scan results. Each entry
represents an access point scanned in the network."
::= { orinocoRAD 6 }
oriRADScanResultsTableEntry OBJECT-TYPE
SYNTAX OriRADScanResultsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the RAD scan results table."
INDEX { oriRADScanResultsTableIndex }
::= { oriRADScanResultsTable 1 }
OriRADScanResultsTableEntry ::=
SEQUENCE
{
oriRADScanResultsTableIndex Integer32,
oriRADScanResultsMACAddress PhysAddress,
oriRADScanResultsFrequencyChannel Integer32
}
oriRADScanResultsTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as the index to the scan results table."
::= { oriRADScanResultsTableEntry 1 }
oriRADScanResultsMACAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the MAC address of the access point detected during
a RAD scan."
::= { oriRADScanResultsTableEntry 2 }
oriRADScanResultsFrequencyChannel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the frequency channel of the access point."
::= { oriRADScanResultsTableEntry 3 }
--=============================================================================
-- The Rogue Scan Subgroup: orinocoRogueScan
--=============================================================================
oriRogueScanConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriRogueScanConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to configure the Rogue Scan feature per wireless
network interface card."
::= { orinocoRogueScan 1 }
oriRogueScanConfigTableEntry OBJECT-TYPE
SYNTAX OriRogueScanConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the Rogue Scan Config Table."
INDEX { ifIndex }
::= { oriRogueScanConfigTable 1 }
OriRogueScanConfigTableEntry ::=
SEQUENCE
{
oriRogueScanConfigTableScanMode INTEGER,
oriRogueScanConfigTableScanCycleTime Integer32,
oriRogueScanConfigTableScanStatus ObjStatus
}
oriRogueScanConfigTableScanMode OBJECT-TYPE
SYNTAX INTEGER
{
bkScanMode(1),
contScanMode(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to configure the scan mode for the wireless NIC."
DEFVAL { bkScanMode }
::= { oriRogueScanConfigTableEntry 1 }
oriRogueScanConfigTableScanCycleTime OBJECT-TYPE
SYNTAX Integer32 (1..1440)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to configure the rogue scan cycle time for the
wireless NIC."
DEFVAL { 1 }
::= { oriRogueScanConfigTableEntry 2 }
oriRogueScanConfigTableScanStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to enable/disable rogue scan on the wireless
NIC."
::= { oriRogueScanConfigTableEntry 3 }
oriRogueScanStationCountWirelessCardA OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of stations that were
discovered/detected on the device's wireless NIC A."
::= { orinocoRogueScan 2 }
oriRogueScanStationCountWirelessCardB OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of stations that were
discovered/detected on the device's wireless NIC B."
::= { orinocoRogueScan 3 }
oriRogueScanResultsTableAgingTime OBJECT-TYPE
SYNTAX Integer32 (60..7200)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the aging time for the entries in
RogueScanResultsTable, after which the entries are removed from
RogueScanResultsTable."
DEFVAL { 60 }
::= { orinocoRogueScan 4 }
oriRogueScanResultsTableClearEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to remove the content/entries of
RogueScanResultsTable. When this object is set, the content of the
table shall be cleared."
::= { orinocoRogueScan 5 }
oriRogueScanResultsNotificationMode OBJECT-TYPE
SYNTAX INTEGER
{
noNotification(1),
notifyAP(2),
notifyClient(3),
notifyAll(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to configure the trap/notification mode for
detected stations during Rogue Scan."
DEFVAL { notifyAll }
::= { orinocoRogueScan 6 }
oriRogueScanResultsTrapReportType OBJECT-TYPE
SYNTAX INTEGER
{
reportSinceLastScan(1),
reportSinceStartOfScan(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to configure the trap/notification report type
for detected stations during Rogue Scan."
DEFVAL { reportSinceLastScan }
::= { orinocoRogueScan 7 }
oriRogueScanResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriRogueScanResultsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to store the rogue scan results. Each entry
represents a rogue wireless station detected in the network."
::= { orinocoRogueScan 8 }
oriRogueScanResultsTableEntry OBJECT-TYPE
SYNTAX OriRogueScanResultsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the rogue scan results table."
INDEX { oriRogueScanResultsTableIndex }
::= { oriRogueScanResultsTable 1 }
OriRogueScanResultsTableEntry ::=
SEQUENCE
{
oriRogueScanResultsTableIndex Integer32,
oriRogueScanResultsStationType INTEGER,
oriRogueScanResultsMACAddress PhysAddress,
oriRogueScanResultsFrequencyChannel DisplayString,
oriRogueScanResultsSNR Integer32,
oriRogueScanResultsBSSID MacAddress
}
oriRogueScanResultsTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as the index to the rogue scan results table."
::= { oriRogueScanResultsTableEntry 1 }
oriRogueScanResultsStationType OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
infrastructureClient(2),
accessPoint(3),
ibssClient(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the type of station detected during a
rogue scan."
::= { oriRogueScanResultsTableEntry 2 }
oriRogueScanResultsMACAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the MAC address of the station detected during
a rogue scan."
::= { oriRogueScanResultsTableEntry 3 }
oriRogueScanResultsFrequencyChannel OBJECT-TYPE
SYNTAX DisplayString (SIZE(32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the frequency channel on which the rogue
wireless stations was detected."
::= { oriRogueScanResultsTableEntry 5 }
oriRogueScanResultsSNR OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the signal to noise ration (SNR) for the
station detected during a rogue scan."
::= { oriRogueScanResultsTableEntry 6 }
oriRogueScanResultsBSSID OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents BSSID of the station detected during a
rogue scan."
::= { oriRogueScanResultsTableEntry 7 }
--=============================================================================
-- The Security Configuration Table: oriSecurityConfigTable
--=============================================================================
oriSecurityConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriSecurityConfigTableEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This table is used to specify the security configuration for
the wireless interface(s) in the access point."
::= { orinocoSecurity 5 }
oriSecurityConfigTableEntry OBJECT-TYPE
SYNTAX OriSecurityConfigTableEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This object represents an entry in the security configuration table."
INDEX { ifIndex }
::= { oriSecurityConfigTable 1 }
OriSecurityConfigTableEntry ::=
SEQUENCE
{
oriSecurityConfigTableSupportedSecurityModes DisplayString,
oriSecurityConfigTableSecurityMode INTEGER,
oriSecurityConfigTableRekeyingInterval Integer32,
oriSecurityConfigTableEncryptionKeyLength INTEGER
}
oriSecurityConfigTableSupportedSecurityModes OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object is used to provide information on the supported
security modes by the wireless interface(s). The possible security
modes can be:
- None: no security mode enabled.
- dot1x: 802.1x authentication enabled.
- mixed: mixed WEP and 802.1x.
- wpa: WiFi Protected Access enabled.
- wpa-psk: WiFi Protected Access with Preshared Keys enabled."
::= { oriSecurityConfigTableEntry 1 }
oriSecurityConfigTableSecurityMode OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
dot1x(2),
mixed(3),
wpa(4),
wpa-psk(5)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object is used to configure the security mode. The supported
security modes are:
- None: no security mode enabled.
- dot1x: 802.1x authentication enabled.
- mixed: mixed WEP and 802.1x.
- wpa: WiFi Protected Access enabled.
- wpa-psk: WiFi Protected Access with Preshared Keys enabled."
DEFVAL { none }
::= { oriSecurityConfigTableEntry 2 }
oriSecurityConfigTableRekeyingInterval OBJECT-TYPE
SYNTAX Integer32 (60..65535)
UNITS "seconds"
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object represents the encryption rekeying interval in seconds."
::= { oriSecurityConfigTableEntry 3 }
oriSecurityConfigTableEncryptionKeyLength OBJECT-TYPE
SYNTAX INTEGER
{
sixtyFourBits(1),
oneHundredTwentyEightBits(2),
oneHundredFiftyTwoBits(3)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object represents the encryption key length, the supported
key lengths are 64 bits (40 + 24 for IV), 128 bits
(104 + 24 for IV), and 152 bits (128 + 24 for IV)."
DEFVAL { sixtyFourBits }
::= { oriSecurityConfigTableEntry 4 }
oriSecurityHwConfigResetStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable/disable the status of configuration
reset using the hardware reset button."
DEFVAL { enable }
::= { orinocoSecurity 6 }
oriSecurityHwConfigResetPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE(6..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the configuration reset password. This object
should be treated as write-only and returned as asterisks."
::= { orinocoSecurity 7 }
--=============================================================================
-- The Security Profile Table: oriSecurityProfileTable
--=============================================================================
oriSecurityProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriSecurityProfileTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to configure a security profile. A security
profile can consist of single or muliple security modes."
::= { orinocoSecurity 9 }
oriSecurityProfileTableEntry OBJECT-TYPE
SYNTAX OriSecurityProfileTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the security profile table.
This table is index by two indices - the first/primary index defines
the security profile, the second index defines a single or multiple
security policies per profile. The primary index is used in the
wireless interface SSID table to specify which security profile to
use per SSID.
The admin/user can configure policies for different wireless station
types by specifying a authentication and cipher mode/type. Below are
examples of how to configure different STA types.
STA Type Authentication Mode Cipher Mode
======== =================== ===========
Non Secure None None
WEP None WEP (64, 128, 152)
802.1x 802.1x WEP (64, 128)
WPA 802.1x TKIP
WPA-PSK PSK TKIP
802.11i 802.1x AES
802.11i-PSK PSK AES
In the case of None, WEP, WPA-PSK, and 802.11i-PSK, MAC Access Control
Table/List and RADIUS based MAC access control can be used to
authenticate the wireless STA."
INDEX { oriSecurityProfileTableIndex,
oriSecurityProfileTableSecModeIndex }
::= { oriSecurityProfileTable 1 }
OriSecurityProfileTableEntry ::=
SEQUENCE
{
oriSecurityProfileTableIndex Integer32,
oriSecurityProfileTableSecModeIndex Integer32,
oriSecurityProfileTableAuthenticationMode INTEGER,
oriSecurityProfileTableCipherMode INTEGER,
oriSecurityProfileTableEncryptionKey0 WEPKeyType,
oriSecurityProfileTableEncryptionKey1 WEPKeyType,
oriSecurityProfileTableEncryptionKey2 WEPKeyType,
oriSecurityProfileTableEncryptionKey3 WEPKeyType,
oriSecurityProfileTableEncryptionTxKey Integer32,
oriSecurityProfileTableEncryptionKeyLength INTEGER,
oriSecurityProfileTablePSKValue OCTET STRING,
oriSecurityProfileTablePSKPassPhrase DisplayString,
oriSecurityProfileTableStatus RowStatus
}
oriSecurityProfileTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the primary index of the Security Policy
Table. This index is used to specify which security policy will
be used per SSID, in the Wireless Interface SSID Table. A security
policy can consist of a single or multiple security modes."
::= { oriSecurityProfileTableEntry 1 }
oriSecurityProfileTableSecModeIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the secondary index to the Security Policy Table.
This index will represent the different security modes per security
profile."
::= { oriSecurityProfileTableEntry 2 }
oriSecurityProfileTableAuthenticationMode OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
dot1x(2),
psk(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to specify the authentication mode for the
security mode."
DEFVAL { none }
::= { oriSecurityProfileTableEntry 3 }
oriSecurityProfileTableCipherMode OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
wep(2),
tkip(3),
aes(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to specify the cipher mode/type for the security
mode."
DEFVAL { none }
::= { oriSecurityProfileTableEntry 4 }
oriSecurityProfileTableEncryptionKey0 OBJECT-TYPE
SYNTAX WEPKeyType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents Encryption Key 0. This object should be
treated as write-only and returned as asterisks."
::= { oriSecurityProfileTableEntry 5 }
oriSecurityProfileTableEncryptionKey1 OBJECT-TYPE
SYNTAX WEPKeyType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents Encryption Key 1. This object should be
treated as write-only and returned as asterisks."
::= { oriSecurityProfileTableEntry 6 }
oriSecurityProfileTableEncryptionKey2 OBJECT-TYPE
SYNTAX WEPKeyType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents Encryption Key 2. This object should be
treated as write-only and returned as asterisks."
::= { oriSecurityProfileTableEntry 7 }
oriSecurityProfileTableEncryptionKey3 OBJECT-TYPE
SYNTAX WEPKeyType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents Encryption Key 3. This object should be
treated as write-only and returned as asterisks."
::= { oriSecurityProfileTableEntry 8 }
oriSecurityProfileTableEncryptionTxKey OBJECT-TYPE
SYNTAX Integer32 (0..3)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates which encryption key is used to encrypt
data that is sent via the wireless interfaces. The default value
for this object should be key 0."
DEFVAL { 0 }
::= { oriSecurityProfileTableEntry 9 }
oriSecurityProfileTableEncryptionKeyLength OBJECT-TYPE
SYNTAX INTEGER
{
sixtyFourBits(1),
oneHundredTwentyEightBits(2),
oneHundredFiftyTwoBits(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the encryption key length, the supported
key lengths are 64 bits (40 + 24 for IV), 128 bits
(104 + 24 for IV), and 152 bits (128 + 24 for IV)."
DEFVAL { sixtyFourBits }
::= { oriSecurityProfileTableEntry 10 }
oriSecurityProfileTablePSKValue OBJECT-TYPE
SYNTAX OCTET STRING ( SIZE (32) )
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Pre-Shared Key (PSK) for when RSN in PSK mode is the selected
authentication suite. In that case, the PMK will obtain its value
from this object.
This object is logically write-only. Reading this variable shall
return unsuccessful status or null or zero."
::= { oriSecurityProfileTableEntry 11 }
oriSecurityProfileTablePSKPassPhrase OBJECT-TYPE
SYNTAX DisplayString ( SIZE( 8..63) )
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The PSK, for when RSN in PSK mode is the selected authentication
suite, is configured by oriWirelessIfSSIDTablePSKValue. An alternative
manner of setting the PSK uses the password-to-key algorithm defined
in the standard. This variable provides a means to enter a pass phrase.
When this object is written, the RSN entity shall use the
password-to-key algorithm specified in the standard to derive a
pre-shared and populate oriWirelessIfSSIDTablePSKValue with this key.
This object is logically write-only. Reading this variable shall
return unsuccessful status or null or zero."
::= { oriSecurityProfileTableEntry 12 }
oriSecurityProfileTableStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the Table row status."
::= { oriSecurityProfileTableEntry 14 }
oriSecurityProfileFourWEPKeySupport OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to configure the security profile to use
with four WEP keys. Currently only one security profile can be active
which supports four WEP keys. Therefore this object is used to
specify which profile will be using four WEP keys. The purpose of
this object is to support legacy products/users that are still using
four WEP keys."
::= { orinocoSecurity 10 }
--=============================================================================
-- The PPPoE Group: orinocoPPPoE
--=============================================================================
oriPPPoEStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows to enable or disable the PPPoE service in the
device."
DEFVAL { disable }
::= { orinocoPPPoE 1 }
oriPPPoEMaximumNumberOfSessions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the maximum number of PPPoE sessions."
DEFVAL { 10 }
::= { orinocoPPPoE 2 }
oriPPPoENumberOfActiveSessions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of active PPPoE sessions."
::= { orinocoPPPoE 3 }
oriPPPoESessionTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriPPPoESessionTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to configure the PPPoE session information."
::= { orinocoPPPoE 4 }
oriPPPoESessionTableEntry OBJECT-TYPE
SYNTAX OriPPPoESessionTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the PPPoE session table."
INDEX { oriPPPoESessionTableIndex }
::= { oriPPPoESessionTable 1 }
OriPPPoESessionTableEntry ::=
SEQUENCE
{
oriPPPoESessionTableIndex Integer32,
oriPPPoESessionWANConnectMode INTEGER,
oriPPPoESessionIdleTimeOut Integer32,
oriPPPoESessionConnectTime Counter32,
oriPPPoESessionConnectTimeLimitation Integer32,
oriPPPoESessionConfigPADITxInterval Integer32,
oriPPPoESessionConfigPADIMaxNumberOfRetries Integer32,
oriPPPoESessionBindingsNumberPADITx Counter32,
oriPPPoESessionBindingsNumberPADTTx Counter32,
oriPPPoESessionBindingsNumberServiceNameErrors Counter32,
oriPPPoESessionBindingsNumberACSystemErrors Counter32,
oriPPPoESessionBindingsNumberGenericErrorsRx Counter32,
oriPPPoESessionBindingsNumberGenericErrorsTx Counter32,
oriPPPoESessionBindingsNumberMalformedPackets Counter32,
oriPPPoESessionBindingsNumberMultiplePADORx Counter32,
oriPPPoESessionUserName DisplayString,
oriPPPoESessionUserNamePassword DisplayString,
oriPPPoESessionServiceName DisplayString,
oriPPPoESessionISPName DisplayString,
oriPPPoESessionTableStatus INTEGER,
oriPPPoESessionWANManualConnect INTEGER,
oriPPPoESessionWANConnectionStatus INTEGER
}
oriPPPoESessionTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as the index to the PPPoE Session Table."
::= { oriPPPoESessionTableEntry 1 }
oriPPPoESessionWANConnectMode OBJECT-TYPE
SYNTAX INTEGER
{
alwaysOn(1),
onDemand(2),
manual(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the WAN connect mode."
DEFVAL { alwaysOn }
::= { oriPPPoESessionTableEntry 2 }
oriPPPoESessionIdleTimeOut OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used as a timeout for the PPPoE session to be
disconnected from public side if idle for specified amount of
time."
::= { oriPPPoESessionTableEntry 3 }
oriPPPoESessionConnectTime OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the PPPoE session connect time."
::= { oriPPPoESessionTableEntry 4 }
oriPPPoESessionConnectTimeLimitation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the maximum connection time per session."
DEFVAL { 0 }
::= { oriPPPoESessionTableEntry 5 }
oriPPPoESessionConfigPADITxInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the time in seconds between PADI retries
from the Host."
::= { oriPPPoESessionTableEntry 6 }
oriPPPoESessionConfigPADIMaxNumberOfRetries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the number of times the Host sends
a PADI."
::= { oriPPPoESessionTableEntry 7 }
oriPPPoESessionBindingsNumberPADITx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of PPPoE PADI transmitted."
::= { oriPPPoESessionTableEntry 8 }
oriPPPoESessionBindingsNumberPADTTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of PPPoE PADT transmitted."
::= { oriPPPoESessionTableEntry 9 }
oriPPPoESessionBindingsNumberServiceNameErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of PPPoE Service-Name-Error
tags received/transmitted."
::= { oriPPPoESessionTableEntry 10 }
oriPPPoESessionBindingsNumberACSystemErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of PPPoE AC-System-Error
tags received/transmitted."
::= { oriPPPoESessionTableEntry 11 }
oriPPPoESessionBindingsNumberGenericErrorsRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of PPPoE Generic-Error
tags received."
::= { oriPPPoESessionTableEntry 12 }
oriPPPoESessionBindingsNumberGenericErrorsTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of PPPoE Generic Error
tags transmitted."
::= { oriPPPoESessionTableEntry 13 }
oriPPPoESessionBindingsNumberMalformedPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents teh number of malformed PPPoE
packets received."
::= { oriPPPoESessionTableEntry 14 }
oriPPPoESessionBindingsNumberMultiplePADORx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of PPPoE multiple PADO's
received after a PADI request."
::= { oriPPPoESessionTableEntry 15 }
oriPPPoESessionUserName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the PPPoE user name."
::= { oriPPPoESessionTableEntry 16 }
oriPPPoESessionUserNamePassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the PPPoE user name password. This object
should be treated as write-only and returned as asterisks."
::= { oriPPPoESessionTableEntry 17 }
oriPPPoESessionServiceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the PPPoE service name."
::= { oriPPPoESessionTableEntry 18 }
oriPPPoESessionISPName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the PPPoE ISP name."
::= { oriPPPoESessionTableEntry 19 }
oriPPPoESessionTableStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the PPPoE ISP table entry status."
::= { oriPPPoESessionTableEntry 20 }
oriPPPoESessionWANManualConnect OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to connect of disconnect the PPPoE session
when the connect mode is set to manual."
::= { oriPPPoESessionTableEntry 21 }
oriPPPoESessionWANConnectionStatus OBJECT-TYPE
SYNTAX INTEGER
{
null(1),
start(2),
addingStack(3),
stackAdded(4),
stackAddError(5),
connectFailed(6),
authFailed(7),
up(8),
down(9),
suspended(10),
unknown(11)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the state of the PPPoE WAN connection
interface."
::= { oriPPPoESessionTableEntry 22 }
oriPPPoEMACtoSessionTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriPPPoEMACtoSessionTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to map client MAC address to PPPoE Session
information for an ISP."
::= { orinocoPPPoE 5 }
oriPPPoEMACtoSessionTableEntry OBJECT-TYPE
SYNTAX OriPPPoEMACtoSessionTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the PPPoE MAC to
Session table."
INDEX { oriPPPoEMACtoSessionTableIndex }
::= { oriPPPoEMACtoSessionTable 1 }
OriPPPoEMACtoSessionTableEntry ::=
SEQUENCE
{
oriPPPoEMACtoSessionTableIndex Integer32,
oriPPPoEMACtoSessionTableMACAddress PhysAddress,
oriPPPoEMACtoSessionTableISPName DisplayString,
oriPPPoEMACtoSessionTableStatus INTEGER
}
oriPPPoEMACtoSessionTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as the index to the PPPoE Session Table."
::= { oriPPPoEMACtoSessionTableEntry 1 }
oriPPPoEMACtoSessionTableMACAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the client MAC address."
::= { oriPPPoEMACtoSessionTableEntry 2 }
oriPPPoEMACtoSessionTableISPName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the ISP name."
::= { oriPPPoEMACtoSessionTableEntry 3 }
oriPPPoEMACtoSessionTableStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the PPPoE MAC to Session table
entry status."
::= { oriPPPoEMACtoSessionTableEntry 4 }
--=============================================================================
-- The Configuration Group: orinocoConfig
--=============================================================================
oriConfigResetToDefaults OBJECT-TYPE
SYNTAX INTEGER
{
bridgeMode(1),
gatewayMode(2),
gatewayModeDHCPClient(3),
gatewayModePPPoE(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the quickstart modes that the
device can be configured in."
DEFVAL { gatewayMode }
::= { orinocoConfig 1 }
oriConfigFileTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriConfigFileTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the current configuration files stored in the
device. This table is used to manage the different configuration
files."
::= { orinocoConfig 2 }
oriConfigFileTableEntry OBJECT-TYPE
SYNTAX OriConfigFileTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the configuration file table."
INDEX { oriConfigFileTableIndex }
::= { oriConfigFileTable 1 }
OriConfigFileTableEntry ::=
SEQUENCE
{
oriConfigFileTableIndex Integer32,
oriConfigFileName DisplayString,
oriConfigFileStatus INTEGER
}
oriConfigFileTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the index to the configuration file
table."
::= { oriConfigFileTableEntry 1 }
oriConfigFileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the configuration file name."
::= { oriConfigFileTableEntry 2 }
oriConfigFileStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the status of the configuration file.
The possible options are:
- Enable: active configuration file
- Disable: inactive configuration file
- Delete: in order to delete the configuration file"
::= { oriConfigFileTableEntry 3 }
oriConfigSaveFile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object saves the configuration to the specified name."
::= { orinocoConfig 3 }
oriConfigSaveKnownGood OBJECT-TYPE
SYNTAX INTEGER
{
saveKnownGood(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to identify the last know good configuration
file used. Setting a value of 1 to this objecgt saves the current
configuration as the known good configuration."
::= { orinocoConfig 4 }
--=============================================================================
-- The DNS Group: orinocoDNS
--=============================================================================
--=============================================================================
-- The DNS Redirect Group: orinocoDNS
--=============================================================================
oriDNSRedirectStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the DNS Redirect
functionality."
DEFVAL { enable }
::= { orinocoDNS 1 }
oriDNSRedirectMaxResponseWaitTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the maximum response wait time for
DNS redirect. The units for this object is seconds."
DEFVAL { 10 }
::= { orinocoDNS 2 }
oriDNSPrimaryDNSIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the Primary DNS IP Address."
::= { orinocoDNS 3 }
oriDNSSecondaryDNSIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the Secondary DNS IP Address."
::= { orinocoDNS 4 }
--=============================================================================
-- The DNS Client Subgroup: orinocoDNSClient
--=============================================================================
oriDNSClientStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the DNS Client feature."
DEFVAL { disable }
::= { orinocoDNSClient 1 }
oriDNSClientPrimaryServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the Primary Server DNS IP Address."
::= { orinocoDNSClient 2 }
oriDNSClientSecondaryServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the Secondary Server DNS IP Address."
::= { orinocoDNSClient 3 }
oriDNSClientDefaultDomainName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the default domain name for the DNS Client."
::= { orinocoDNSClient 4 }
--=============================================================================
-- The AOL Group: orinocoAOL
--=============================================================================
oriAOLNATALGStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable/disable the AOL NAT Application
Level Gateway (ALG) support."
DEFVAL { disable }
::= { orinocoAOL 1 }
--=============================================================================
-- The NAT Group: orinocoNAT
--=============================================================================
oriNATStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable/disable the NAT feature."
DEFVAL { disable }
::= { orinocoNAT 1 }
oriNATType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A Bit Mask documenting the NAT device's actual
configuration according to natTypeMask above.
Its value may be one and only one of the options below:
- Basic-NAT (Bit 0)
- NAPT (Bit 1)
- Bi-directional-NAT (Bit 2)
- Twice-NAT (Bit 3)
- RSA-IP-Server (Bit 4)
- RSAP-IP-Server (Bit 5)
- Bit 0, if set, indicates that Basic-NAT is configured.
- Bit 1, if set, indicates that NAPT is configured.
- Bit 2, if set, indicates that Bi-directional-NAT
is configured.
- Bit 3, if set, indicates that Twice-NAT is configured.
- Bit 4, if set, indicates that RSA-IP-Server is
configured.
- Bit 5, if set, indicates that RSAP-IP-Server
is configured."
::= { orinocoNAT 2 }
oriNATStaticBindStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable static bind entries
on the NAT device."
::= { orinocoNAT 3 }
oriNATPublicIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to provide information on the NAT public IP
Address."
::= { orinocoNAT 4 }
oriNATStaticIPBindTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriNATStaticIPBindTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains NAT IP bind specific information."
::= { orinocoNAT 5 }
oriNATStaticIPBindTableEntry OBJECT-TYPE
SYNTAX OriNATStaticIPBindTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is an entry in the NAT Static IP Bind Table."
INDEX { oriNATStaticIPBindTableIndex }
::= { oriNATStaticIPBindTable 1 }
OriNATStaticIPBindTableEntry ::=
SEQUENCE
{
oriNATStaticIPBindTableIndex Integer32,
oriNATStaticIPBindLocalAddress IpAddress,
oriNATStaticIPBindRemoteAddress IpAddress,
oriNATStaticIPBindTableEntryStatus INTEGER
}
oriNATStaticIPBindTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as the index for the NAT static IP
bind table."
::= { oriNATStaticIPBindTableEntry 1 }
oriNATStaticIPBindLocalAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the local IP address for this NAT
Static IP bind Table entry."
::= { oriNATStaticIPBindTableEntry 2 }
oriNATStaticIPBindRemoteAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the remote IP address for this NAT
Static IP bind Table entry."
::= { oriNATStaticIPBindTableEntry 3 }
oriNATStaticIPBindTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object indicates the status of the NAT Static IP Bind
Table entry."
::= { oriNATStaticIPBindTableEntry 4 }
oriNATStaticPortBindTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriNATStaticPortBindTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to configure NAT Port bind specific
information."
::= { orinocoNAT 6 }
oriNATStaticPortBindTableEntry OBJECT-TYPE
SYNTAX OriNATStaticPortBindTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the NAT Static Port Bind
Table."
INDEX { oriNATStaticPortBindTableIndex }
::= { oriNATStaticPortBindTable 1 }
OriNATStaticPortBindTableEntry ::=
SEQUENCE
{
oriNATStaticPortBindTableIndex Integer32,
oriNATStaticPortBindLocalAddress IpAddress,
oriNATStaticPortBindStartPortNumber Integer32,
oriNATStaticPortBindEndPortNumber Integer32,
oriNATStaticPortBindPortType INTEGER,
oriNATStaticPortBindTableEntryStatus INTEGER
}
oriNATStaticPortBindTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as the index for the NAT static Port
bind table."
::= { oriNATStaticPortBindTableEntry 1 }
oriNATStaticPortBindLocalAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the local IP address for this NAT Static
Port bind Table entry."
::= { oriNATStaticPortBindTableEntry 2 }
oriNATStaticPortBindStartPortNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the start port number for this NAT Static
Port bind Table entry."
::= { oriNATStaticPortBindTableEntry 3 }
oriNATStaticPortBindEndPortNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the end port number for this NAT Static
Port bind Table entry."
::= { oriNATStaticPortBindTableEntry 4 }
oriNATStaticPortBindPortType OBJECT-TYPE
SYNTAX INTEGER
{
tcp(1),
udp(2),
both(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the port type for this NAT Static
Port bind Table entry."
::= { oriNATStaticPortBindTableEntry 5 }
oriNATStaticPortBindTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object indicates the status of the NAT Static Port Bind
Table entry."
::= { oriNATStaticPortBindTableEntry 6 }
--=============================================================================
-- The SpectraLink VoIP Group: orinocoSpectraLink
--=============================================================================
oriSpectraLinkStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the SpectraLink VoIP
feature."
DEFVAL { disable }
::= { orinocoSpectraLink 1 }
oriSpectraLinkLegacyDeviceSupport OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable/disable SpectraLink VoIP support for
legacy SpectraLink devices/phones."
DEFVAL { disable }
::= { orinocoSpectraLink 2 }
--=============================================================================
-- The VLAN Group: orinocoVLAN
--=============================================================================
oriVLANStatus OBJECT-TYPE
SYNTAX ObjStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the VLAN feature."
DEFVAL { disable }
::= { orinocoVLAN 1 }
oriVLANMgmtIdentifier OBJECT-TYPE
SYNTAX VlanId
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the VLAN management Identifier (ID)."
DEFVAL { -1 }
::= { orinocoVLAN 2 }
oriVLANIDTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriVLANIDTableEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This table is used to configure the VLAN IDs for the device. This
table has been deprecated."
::= { orinocoVLAN 3 }
oriVLANIDTableEntry OBJECT-TYPE
SYNTAX OriVLANIDTableEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This object represents an entry in the respective table. In this
case each table entry represents a VLAN ID. This object has been
deprecated."
INDEX { oriVLANIDTableIndex }
::= { oriVLANIDTable 1 }
OriVLANIDTableEntry ::=
SEQUENCE
{
oriVLANIDTableIndex Integer32,
oriVLANIDTableIdentifier VlanId
}
oriVLANIDTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object represents the index to the VLAN ID Table. This object
has been deprecated."
::= { oriVLANIDTableEntry 1 }
oriVLANIDTableIdentifier OBJECT-TYPE
SYNTAX VlanId
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object represents the VLAN Identifier (ID). This object has been
deprecated."
DEFVAL { 0 }
::= { oriVLANIDTableEntry 2 }
--=============================================================================
-- The DMZ Group: orinocoDMZ
--=============================================================================
oriDMZHostTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriDMZHostTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing DMZ host IP information.
Only if the system is in Gateway mode, and the NAT is enabled,
and this table has valid 'enabled' entry, the DMZ takes effect."
::= { orinocoDMZ 1 }
oriDMZHostTableEntry OBJECT-TYPE
SYNTAX OriDMZHostTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the DMZ host IP Table."
INDEX { oriDMZHostTableIndex }
::= { oriDMZHostTable 1 }
OriDMZHostTableEntry ::=
SEQUENCE
{
oriDMZHostTableIndex Integer32,
oriDMZHostTableHostIP IpAddress,
oriDMZHostTableComment DisplayString,
oriDMZHostTableEntryStatus INTEGER
}
oriDMZHostTableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as the index for the DMZ host IP Table."
::= { oriDMZHostTableEntry 1 }
oriDMZHostTableHostIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the DMZ host IP address."
::= { oriDMZHostTableEntry 2 }
oriDMZHostTableComment OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This objecgt is used for an optional comment associated to the
DMZ host IP Table entry."
::= { oriDMZHostTableEntry 3 }
oriDMZHostTableEntryStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object indicates the status of the DMZ host IP Table entry."
::= { oriDMZHostTableEntry 4 }
--=============================================================================
-- The OEM Group: orinocoOEM
--=============================================================================
oriOEMName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to specify the OEM name."
::= { orinocoOEM 1 }
oriOEMHomeUrl OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to specify the OEM home URL."
::= { orinocoOEM 2 }
oriOEMProductName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the product name. It is the same name as
shown in all management Web pages."
::= { orinocoOEM 3 }
oriOEMProductModel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the product model."
::= { orinocoOEM 4 }
oriOEMLogoImageFile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the name of logo image file."
::= { orinocoOEM 5 }
oriOEMNoNavLogoImageFile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the name of no nav. logo image file."
::= { orinocoOEM 6 }
--=============================================================================
-- The Station Statistics Group: orinocoStationsStatistics
--=============================================================================
oriStationStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF OriStationStatTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains wireless stations statistics."
::= { orinocoStationStatistics 1 }
oriStationStatTableEntry OBJECT-TYPE
SYNTAX OriStationStatTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents an entry in the respective table. In this
case each table entry represents a wireless station."
INDEX { oriStationStatTableIndex }
::= { oriStationStatTable 1 }
OriStationStatTableEntry ::=
SEQUENCE
{
oriStationStatTableIndex Integer32,
oriStationStatTableMACAddress MacAddress,
oriStationStatTableIPAddress IpAddress,
oriStationStatTableInterface Integer32,
oriStationStatTableName DisplayString,
oriStationStatTableType INTEGER,
oriStationStatTableMACProtocol INTEGER,
oriStationStatTableAdminStatus INTEGER,
oriStationStatTableOperStatus INTEGER,
oriStationStatTableLastChange TimeTicks,
oriStationStatTableLastState INTEGER,
oriStationStatTableInOctets Counter32,
oriStationStatTableInUcastPkts Counter32,
oriStationStatTableInNUcastPkts Counter32,
oriStationStatTableInDiscards Counter32,
oriStationStatTableOutOctets Counter32,
oriStationStatTableOutUcastPkts Counter32,
oriStationStatTableOutNUcastPkts Counter32,
oriStationStatTableOutDiscards Counter32,
oriStationStatTableInSignal Integer32,
oriStationStatTableInNoise Integer32,
oriStationStatTableRemoteSignal Integer32,
oriStationStatTableRemoteNoise Integer32,
oriStationStatTableLastInPktTime TimeTicks
}
oriStationStatTableIndex OBJECT-TYPE
SYNTAX Integer32 (0..500)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the index of the stations statistics
table. This table is limited to 500 entries."
::= { oriStationStatTableEntry 1 }
oriStationStatTableMACAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the MAC address of the station for which
the statistics are gathered."
::= { oriStationStatTableEntry 2 }
oriStationStatTableIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the IP address of the stations for which
the statistics are gathered. If the IP address is not known,
0.0.0.0 will be returned."
::= { oriStationStatTableEntry 3 }
oriStationStatTableInterface OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of the interface on which the
station is last seen."
::= { oriStationStatTableEntry 4 }
oriStationStatTableName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the name of the station. If the name is
not known, an empty string will be returned."
::= { oriStationStatTableEntry 5 }
oriStationStatTableType OBJECT-TYPE
SYNTAX INTEGER
{
sta(1),
wds(2),
worpBase(3),
worpSatellite(4),
norc(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the type of station."
::= { oriStationStatTableEntry 6 }
oriStationStatTableMACProtocol OBJECT-TYPE
SYNTAX INTEGER
{
ieee802dot11(1),
ieee802dot11a(2),
ieee802dot11b(3),
worp(4),
ieee802dot11g(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the MAC protocol for this station."
::= { oriStationStatTableEntry 7 }
oriStationStatTableAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2),
testing(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the administrative state for the station.
The testing(3) state indicates that no operational packets can
be passed."
::= { oriStationStatTableEntry 8 }
oriStationStatTableOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2),
testing(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the current operational state of the
interface. The testing(3) state indicates that no operational
packets can be passed."
::= { oriStationStatTableEntry 9 }
oriStationStatTableLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the value of sysUpTime at the time the
station entered its current operational state. If the current
state was entered prior to the last re-initialization of the
local network management subsystem, then this object contains a
zero value."
::= { oriStationStatTableEntry 10 }
oriStationStatTableLastState OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
registering(2),
authenticating(3),
registered(4),
timeout(5),
aborded(6),
rejected(7),
linktest(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the last state of this station."
::= { oriStationStatTableEntry 11 }
oriStationStatTableInOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets received from the station,
including framing characters."
::= { oriStationStatTableEntry 12 }
oriStationStatTableInUcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of unicast packets from the
station that are further processed by either by the bridge/router
or by the internal host."
::= { oriStationStatTableEntry 13 }
oriStationStatTableInNUcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of non-unicast packets
(i.e. broadcast or multicast) from the station that are further
processed by either by the bridge/router or by the internal host."
::= { oriStationStatTableEntry 14 }
oriStationStatTableInDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of inbound packets which were
chosen to be discarded even though no errors had been detected to
prevent their being deliverable to the internal bridge/router or
the internal host. One possible reason for discarding such a
packet could be to lack of buffer space."
::= { oriStationStatTableEntry 15 }
oriStationStatTableOutOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the total number of octets send to the
station, including framing characters."
::= { oriStationStatTableEntry 16 }
oriStationStatTableOutUcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of packets that the internal
bridge/router or the internal host requested be transmitted to the
station, including those that were discarded or not sent."
::= { oriStationStatTableEntry 17 }
oriStationStatTableOutNUcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of packets that the internal
bridge/router or the internal host requested be transmitted to a
non-unicast (i.e. broadcast or multicast) address that includes
the station. This counter includes those packets that were
discarded or not sent."
::= { oriStationStatTableEntry 18 }
oriStationStatTableOutDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of outbound packets which were
chosen to be discarded even though no errors had been detected to
prevent their being deliverable to the internal bridge/router or
the internal host. One possible reason for discarding such a
packet could be to lack of buffer space."
::= { oriStationStatTableEntry 19 }
oriStationStatTableInSignal OBJECT-TYPE
SYNTAX Integer32 (-102..-10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the current signal level calculated over
the inbound packets from this station. This variable indicates
the running average of the local signal level using the algorithm
(3/4*oldvalue + 1/4*newvalue)."
::= { oriStationStatTableEntry 20 }
oriStationStatTableInNoise OBJECT-TYPE
SYNTAX Integer32 (-102..-10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the current noise level calculated over
the inbound packets from this station. This variable indicates
the running average of the local noise level using the algorithm
(3/4*oldvalue + 1/4*newvalue)."
::= { oriStationStatTableEntry 21 }
oriStationStatTableRemoteSignal OBJECT-TYPE
SYNTAX Integer32 (-102..-10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the current remote signal level calculated
over the inbound packets from this station on the remote station.
This variable indicates the running average of the remote signal
level using the algorithm (3/4*oldvalue + 1/4*newvalue)."
::= { oriStationStatTableEntry 22 }
oriStationStatTableRemoteNoise OBJECT-TYPE
SYNTAX Integer32 (-102..-10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the current remote noise level calculated
over the inbound packets from this station on the remote station.
This variable indicates the running average of the remote noise
level using the algorithm (3/4*oldvalue + 1/4*newvalue)."
::= { oriStationStatTableEntry 23 }
oriStationStatTableLastInPktTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the value of sysUpTime at the time the
last packet from the remote station was received."
::= { oriStationStatTableEntry 24 }
oriStationStatStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the monitoring of the
wireless station statistics."
DEFVAL { disable }
::= { orinocoStationStatistics 2 }
oriStationStatNumberOfClients OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the number of active wireless clients
associated to the access point."
::= { orinocoStationStatistics 3 }
--=============================================================================
-- The Simple Network Time Protocol (SNTP) Group: orinocoSNTP
--=============================================================================
oriSNTPStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable the SNTP functionality."
DEFVAL { disable }
::= { orinocoSNTP 1 }
oriSNTPPrimaryServerNameOrIPAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the primary SNTP server IP address or host
name."
::= { orinocoSNTP 2 }
oriSNTPSecondaryServerNameOrIPAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the secondary SNTP server IP address or host
name."
::= { orinocoSNTP 3 }
oriSNTPTimeZone OBJECT-TYPE
SYNTAX INTEGER
{
dateline(1),
samoa(2),
hawaii(3),
alaska(4),
pacific-us(5),
mountain-us(6),
arizona(7),
central-us(8),
mexico-city(9),
eastern-us(10),
indiana(11),
atlantic-canada(12),
santiago(13),
newfoundland(14),
brasilia(15),
buenos-aires(16),
mid-atlantic(17),
azores(18),
london(19),
western-europe(20),
eastern-europe(21),
cairo(22),
russia-iraq(23),
iran(24),
arabian(25),
afghanistan(26),
pakistan(27),
india(28),
bangladesh(29),
burma(30),
bangkok(31),
australia-wt(32),
hong-kong(33),
beijing(34),
japan-korea(35),
australia-ct(36),
australia-et(37),
central-pacific(38),
new-zealand(39),
tonga(40),
western-samoa(41)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is used for the device to know how to adjust GMT for
local time."
::= { orinocoSNTP 4 }
oriSNTPDateAndTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the Date and Time. The format of this object
is the same as the DateAndTime textual convention."
::= { orinocoSNTP 5 }
oriSNTPDayLightSavingTime OBJECT-TYPE
SYNTAX INTEGER
{
plus-two(1),
plus-one(2),
unchanged(3),
minus-one(4),
minus-two(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the number of hours to adjust for
Daylight Saving Time."
DEFVAL { unchanged }
::= { orinocoSNTP 6 }
oriSNTPYear OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the year. This object can be used to manually
configure the year in case the Date and Time is not retrieved from an
SNTP server."
::= { orinocoSNTP 7 }
oriSNTPMonth OBJECT-TYPE
SYNTAX Integer32 (1..12)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the month. This object can be used to manually
configure the month in case the Date and Time is not retrieved from an
SNTP server."
::= { orinocoSNTP 8 }
oriSNTPDay OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the day of the month. This object can be used
to manually configure the year in case the Date and Time is not
retrieved from an SNTP server."
::= { orinocoSNTP 9 }
oriSNTPHour OBJECT-TYPE
SYNTAX Integer32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the hour of day. This object can be used
to manually configure the hour in case the Date and Time is not
retrieved from an SNTP server."
::= { orinocoSNTP 10 }
oriSNTPMinutes OBJECT-TYPE
SYNTAX Integer32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the minutes. This object can be used to
manually configure the minutes in case the Date and Time is not
retrieved from an SNTP server."
::= { orinocoSNTP 11 }
oriSNTPSeconds OBJECT-TYPE
SYNTAX Integer32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the number of seconds. This object can be used
to manually configure the seconds in case the Date and Time is not
retrieved from an SNTP server."
::= { orinocoSNTP 12 }
--=============================================================================
-- The Configuration Related Trap Group: oriConfigurationTraps
--=============================================================================
oriConfigurationTraps OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This is the configuration related trap/notification group."
::= { orinocoTrap 2 }
oriTrapDNSIPNotConfigured NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable, oriTrapVarMACAddress }
STATUS current
DESCRIPTION
"This traps is generated when the DNS IP Address has not been
configured.
Trap Severity Level: Major."
::= { oriConfigurationTraps 0 3 }
oriTrapRADIUSAuthenticationNotConfigured NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable, oriTrapVarMACAddress }
STATUS current
DESCRIPTION
"This trap is generated when the RADIUS authentication information
has not been configured.
Trap Severity Level: Major."
::= { oriConfigurationTraps 0 5 }
oriTrapRADIUSAccountingNotConfigured NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable, oriTrapVarMACAddress }
STATUS current
DESCRIPTION
"This trap is generated when the RADIUS accounting information
has not been configured.
Trap Severity Level: Major."
::= { oriConfigurationTraps 0 6 }
oriTrapDuplicateIPAddressEncountered NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable, oriTrapVarMACAddress }
STATUS current
DESCRIPTION
"This trap is generated when the device has encountered another
network device with he same IP Address.
Trap Severity Level: Major."
::= { oriConfigurationTraps 0 7 }
oriTrapDHCPRelayServerTableNotConfigured NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is generated when the DHCP relay agent server table is
empty or not configured.
Trap Severity Level: Major."
::= { oriConfigurationTraps 0 8 }
oriTrapWORPIfNetworkSecretNotConfigured NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is generated when the system network authentication
shared secret is not configured.
Trap Severity Level: Major."
::= { oriConfigurationTraps 0 9 }
oriTrapVLANIDInvalidConfiguration NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable, oriWirelessIfNetworkName,
oriVLANIDTableIdentifier }
STATUS current
DESCRIPTION
"This trap is generated when a VLAN ID configuration is invalid.
Trap Severity Level: Major."
::= { oriConfigurationTraps 0 10 }
oriTrapAutoConfigFailure NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable, oriTFTPAutoConfigFilename,
oriTFTPAutoConfigServerIPAddress }
STATUS current
DESCRIPTION
"This trap is generated when the auto configuration failed.
Trap Severity Level: Minor."
::= { oriConfigurationTraps 0 11 }
oriTrapBatchExecFailure NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable, oriTrapVarBatchCLIFilename,
oriTrapVarBatchCLILineNumber, oriTrapVarBatchCLIMessage}
STATUS current
DESCRIPTION
"This trap is generated when the CLI Batch execution fails for the
following reasons.
- Illegal Command is parsed in the CLI Batch File.
- Execution error is encountered while executing CLI Batch file.
- Bigger File Size than 100 Kbytes
Trap Severity Level: Minor."
::= { oriConfigurationTraps 0 12 }
oriTrapBatchFileExecStart NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable, oriTrapVarBatchCLIFilename}
STATUS current
DESCRIPTION
"This trap is generated when the CLI Batch execution begins after
file is uploaded.
Trap Severity Level: Minor."
::= { oriConfigurationTraps 0 13 }
oriTrapBatchFileExecEnd NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable, oriTrapVarBatchCLIFilename,
oriTrapVarBatchCLIMessage }
STATUS current
DESCRIPTION
"This trap is generated when the execution of CLI Batch File Ends.
Trap Severity Level: Minor."
::= { oriConfigurationTraps 0 14 }
--=============================================================================
-- The Security Related Trap Group: oriSecurityTraps
--=============================================================================
oriSecurityTraps OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This is the security related trap/notification group."
::= { orinocoTrap 3 }
oriTrapInvalidEncryptionKey NOTIFICATION-TYPE
OBJECTS { oriTrapVarUnauthorizedClientMACAddress }
STATUS current
DESCRIPTION
"This trap is generated when an invalid encryption key has been
detected.
Trap Severity Level: Critical."
::= { oriSecurityTraps 0 1 }
oriTrapAuthenticationFailure NOTIFICATION-TYPE
OBJECTS { oriTrapVarUnauthorizedClientMACAddress,
oriTrapVarFailedAuthenticationType }
STATUS current
DESCRIPTION
"This trap is generated when a client authentication failure
has occurred. The authentication failures can range from:
- MAC Access Control Table
- RADIUS MAC Authentication
- 802.1x Authentication specifying the EAP-Type
- WORP Mutual Authentication
- SSID Authorization Failure specifying the SSID
- VLAN ID Authorization Failure specifying the VLAN ID
Trap Severity Level: Major."
::= { oriSecurityTraps 0 2 }
oriTrapUnauthorizedManagerDetected NOTIFICATION-TYPE
OBJECTS { oriTrapVarUnauthorizedManagerIPaddress,
oriTrapVarUnAuthorizedManagerCount }
STATUS current
DESCRIPTION
"This trap is generated when an unauthorized manager has
attempted to view and/or modify parameters.
Trap Severity Level: Major."
::= { oriSecurityTraps 0 3 }
oriTrapRADScanComplete NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable }
STATUS current
DESCRIPTION
"This trap is generated when an a RAD scan is successfully completed.
Trap Severity Level: Informational."
::= { oriSecurityTraps 0 4 }
oriTrapRADScanResults NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable }
STATUS current
DESCRIPTION
"This trap is generated in order to provide information on the RAD
Scan results.
Trap Severity Level: Informational."
::= { oriSecurityTraps 0 5 }
oriTrapRogueScanStationDetected NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable }
STATUS current
DESCRIPTION
"This trap is generated when a rogue station is detected.
Trap Severity Level: Informational."
::= { oriSecurityTraps 0 6 }
oriTrapRogueScanCycleComplete NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable }
STATUS current
DESCRIPTION
"This trap is generated when an a rogue scan is successfully completed.
Trap Severity Level: Informational."
::= { oriSecurityTraps 0 7 }
--=============================================================================
-- The Wireless Interface Card Related Trap Group: oriWirelessIfTraps
--=============================================================================
oriWirelessIfTraps OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This is the wireless interface or wireless card related
trap/notification group."
::= { orinocoTrap 4 }
oriTrapWLCNotPresent NOTIFICATION-TYPE
OBJECTS { oriTrapVarWirelessCard }
STATUS current
DESCRIPTION
"This trap is generated when a wireless interface/card is not
present in the device.
Trap Severity Level: Informational."
::= { oriWirelessIfTraps 0 1 }
oriTrapWLCFailure NOTIFICATION-TYPE
OBJECTS { oriTrapVarWirelessCard }
STATUS current
DESCRIPTION
"This trap is generated when a general failure has occured with
the wireless interface/card.
Trap Severity Level: Critical."
::= { oriWirelessIfTraps 0 2 }
oriTrapWLCRemoval NOTIFICATION-TYPE
OBJECTS { oriTrapVarWirelessCard }
STATUS current
DESCRIPTION
"This trap is generated when the wireless interface/card has been
removed from the device.
Trap Severity Level: Critical."
::= { oriWirelessIfTraps 0 3 }
oriTrapWLCIncompatibleFirmware NOTIFICATION-TYPE
OBJECTS { oriTrapVarWirelessCard }
STATUS current
DESCRIPTION
"This trap is generated when the firmware of the wireless
interface/card is incompatible.
Trap Severity Level: Critical."
::= { oriWirelessIfTraps 0 4 }
oriTrapWLCVoltageDiscrepancy NOTIFICATION-TYPE
OBJECTS { oriTrapVarWirelessCard }
STATUS current
DESCRIPTION
"This trap is generated when a non 5 volt card or 3.3 volt
wireless interface/card is inserted in the device.
Trap Severity Level: Critical."
::= { oriWirelessIfTraps 0 5 }
oriTrapWLCIncompatibleVendor NOTIFICATION-TYPE
OBJECTS { oriTrapVarWirelessCard }
STATUS current
DESCRIPTION
"This trap is generated when an incompatible wireless vendor card
is inserted or present in the device.
Trap Severity Level: Critical."
::= { oriWirelessIfTraps 0 6 }
oriTrapWLCFirmwareDownloadFailure NOTIFICATION-TYPE
OBJECTS { oriTrapVarWirelessCard }
STATUS current
DESCRIPTION
"This trap is generated when a failure occurs during the firmware
download process of the wireless interface/card.
Trap Severity Level: Critical."
::= { oriWirelessIfTraps 0 7 }
oriTrapWLCFirmwareFailure NOTIFICATION-TYPE
OBJECTS { oriTrapVarWirelessCard, oriGenericTrapVariable }
STATUS current
DESCRIPTION
"This trap is generated when a failure occurs in the wireless
interface/card firmware.
Trap Severity Level: Critical."
::= { oriWirelessIfTraps 0 8 }
oriTrapWLCRadarInterferenceDetected NOTIFICATION-TYPE
OBJECTS { oriTrapVarWirelessCard, oriGenericTrapVariable }
STATUS current
DESCRIPTION
"This trap is generated when radar interference is detected on the
channel being used by the wireless interface. The generic trap
varible provides information on the channel where interference
was detected.
Trap Severity Level: Major."
::= { oriWirelessIfTraps 0 9 }
--=============================================================================
-- The Operational Related Trap Group: oriOperationalTraps
--=============================================================================
oriOperationalTraps OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This is the operational related trap group group."
::= { orinocoTrap 5 }
oriTrapUnrecoverableSoftwareErrorDetected NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable, oriTrapVarMACAddress,
oriTrapVarTaskSuspended }
STATUS current
DESCRIPTION
"This trap is generated when an unrecoverable software error has
been detected. This trap can signify that a problem/error has occurred
with one or more software modules. This error would cause the software
watch dog timer to expire which would then cause the device to reboot.
Trap Severity Level: Critical."
::= { oriOperationalTraps 0 1 }
oriTrapRADIUSServerNotResponding NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable }
STATUS current
DESCRIPTION
"This trap is generated when no response is received from the
RADIUS server(s) for authentication requests sent from the RADIUS
client in the device.
Trap Severity Level: Major."
::= { oriOperationalTraps 0 2 }
oriTrapModuleNotInitialized NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable }
STATUS current
DESCRIPTION
"This trap is generated when a certain software or hardware module
has not been initialized or failed to be initialized.
Trap Severity Level: Major."
::= { oriOperationalTraps 0 3 }
oriTrapDeviceRebooting NOTIFICATION-TYPE
OBJECTS { oriTrapVarMACAddress, oriGenericTrapVariable,
oriSystemReboot }
STATUS current
DESCRIPTION
"This trap is generated when the device has received a request
to be rebooted.
Trap Severity Level: Informational."
::= { oriOperationalTraps 0 5 }
oriTrapTaskSuspended NOTIFICATION-TYPE
OBJECTS { oriTrapVarTaskSuspended }
STATUS current
DESCRIPTION
"This trap is generated when a task in the device has suspended.
Trap Severity Level: Critical."
::= { oriOperationalTraps 0 6 }
oriTrapBootPFailed NOTIFICATION-TYPE
OBJECTS { oriTrapVarMACAddress }
STATUS current
DESCRIPTION
"This trap is generated when a response to the BootP request is
not received, hence the access point device is not dynamically
assigned an IP Address.
Trap Severity Level: Major."
::= { oriOperationalTraps 0 7 }
oriTrapDHCPFailed NOTIFICATION-TYPE
OBJECTS { oriTrapVarMACAddress }
STATUS current
DESCRIPTION
"This trap is generated when a response to the DHCP client request
is not received, hence the access point device is not dynamically
assigned an IP Address.
Trap Severity Level: Major."
::= { oriOperationalTraps 0 8 }
oriTrapDNSClientLookupFailure NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable }
STATUS current
DESCRIPTION
"This trap is generated when the DNS client attempts to resolve a
specified hostname (DNS lookup) and a failure occurs. This could be
the result of the DNS server being unreachable or returning an error
for the hostname lookup. This trap specified the hostname that was
being resolved.
Trap Severity Level: Major."
::= { oriOperationalTraps 0 9 }
oriTrapSNTPFailure NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is generated when SNTP service is enabled and no response
is received from the configured SNTP servers.
Trap Severity Level: Major."
::= { oriOperationalTraps 0 10 }
oriTrapMaximumNumberOfSubscribersReached NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is generated when maximum number of suscribers has been
reached.
Trap Severity Level: Major."
::= { oriOperationalTraps 0 11 }
oriTrapSSLInitializationFailure NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is generated when the SSL initialization fails.
Trap Severity Level: Major."
::= { oriOperationalTraps 0 12 }
oriTrapWirelessServiceShutdown NOTIFICATION-TYPE
OBJECTS { oriTrapVarWirelessCard }
STATUS current
DESCRIPTION
"This trap is generated when the Wireless Service Shutdown object is
configured to down; in other words the wireless interface has shutdown
services for wireless clients.
Trap Severity Level: Informational."
::= { oriOperationalTraps 0 13 }
oriTrapWirelessServiceResumed NOTIFICATION-TYPE
OBJECTS { oriTrapVarWirelessCard }
STATUS current
DESCRIPTION
"This trap is generated when the Wireless Service Shutdown object is
configured to up; in other words the wireless interface has resumed
service and is ready for wireless client connections.
Trap Severity Level: Informational."
::= { oriOperationalTraps 0 14 }
oriTrapSSHInitializationStatus NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable }
STATUS current
DESCRIPTION
"This trap is generated to provide information on SSH initialization.
Trap Severity Level: Major."
::= { oriOperationalTraps 0 15 }
oriTrapVLANIDUserAssignment NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable }
STATUS current
DESCRIPTION
"This trap is generated when a user gets assigned a VLAN ID from the
RADIUS server.
Trap Severity Level: Informational."
::= { oriOperationalTraps 0 16 }
oriTrapDHCPLeaseRenewal NOTIFICATION-TYPE
OBJECTS { oriTrapVarDHCPServerIPAddress,
oriTrapVarIPAddress,
oriTrapVarSubnetMask,
oriTrapVarDefaultRouterIPAddress }
STATUS current
DESCRIPTION
"This trap is generated when the access point does a DHCP renewal
request and receives new information from the DHCP server.
The variables/objects bound to this trap will provide information on
the DHCP server IP address that replied to the DHCP client request, and
the IP address, subnet mask, and gateway IP address returned from the
DHCP server.
Trap Severity Level: Informational."
::= { oriOperationalTraps 0 17 }
oriTrapTemperatureAlert NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable, oriUnitTemp }
STATUS current
DESCRIPTION
"This trap is generated when the temperature crosses the limit of -30
to 60 degrees celsius.
Trap Severity Level: Major."
::= { oriOperationalTraps 0 18 }
--=============================================================================
-- The Flash Memory Related Trap Group: oriFlashTraps
--=============================================================================
oriFlashTraps OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This is the flash memory related trap group."
::= { orinocoTrap 6 }
oriTrapFlashMemoryEmpty NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is generated when there is no data present in flash
memory - either on the flash card or the onboard flash memory.
Trap Severity Level: Informational."
::= { oriFlashTraps 0 1 }
oriTrapFlashMemoryCorrupted NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable }
STATUS current
DESCRIPTION
"This trap is generated when the data content of flash memory is
corrupted.
Trap Severity Level: Critical."
::= { oriFlashTraps 0 2 }
oriTrapFlashMemoryRestoringLastKnownGoodConfiguration NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is generated when the current/original configuration data
file is found to be corrupted, therefore the device will load the last
known good configuration file.
Trap Severity Level: Informational."
::= { oriFlashTraps 0 3 }
--=============================================================================
-- The TFTP Related Trap Group: oriTFTPTraps
--=============================================================================
oriTFTPTraps OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This is the TFTP related trap group."
::= { orinocoTrap 7 }
oriTrapTFTPFailedOperation NOTIFICATION-TYPE
OBJECTS { oriTrapVarTFTPIPAddress, oriTrapVarTFTPFilename,
oriTrapVarTFTPOperation }
STATUS current
DESCRIPTION
"This trap is generated when a failure has occurred with the TFTP
operation.
Trap Severity Level: Major."
::= { oriTFTPTraps 0 1 }
oriTrapTFTPOperationInitiated NOTIFICATION-TYPE
OBJECTS { oriTrapVarTFTPIPAddress, oriTrapVarTFTPFilename,
oriTrapVarTFTPOperation }
STATUS current
DESCRIPTION
"This trap is generated when a TFTP operation has been initiated.
Trap Severity Level: Informational."
::= { oriTFTPTraps 0 2 }
oriTrapTFTPOperationCompleted NOTIFICATION-TYPE
OBJECTS { oriTrapVarTFTPIPAddress, oriTrapVarTFTPFilename,
oriTrapVarTFTPOperation }
STATUS current
DESCRIPTION
"This trap is generated when a TFTP operation has been completed.
Trap Severity Level: Informational."
::= { oriTFTPTraps 0 3 }
--=============================================================================
-- The Miscellaneous Trap Group: oriMiscTraps
--=============================================================================
oriMiscTraps OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This is the miscellaneous trap group."
::= { orinocoTrap 8 }
--=============================================================================
-- The Image Related Trap Group: oriImageTraps
--=============================================================================
oriImageTraps OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This is the image related trap group."
::= { orinocoTrap 9 }
oriTrapZeroSizeImage NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is generated when a zero size image is loaded on the
device.
Trap Severity Level: Major."
::= { oriImageTraps 0 1 }
oriTrapInvalidImage NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is generated when an invalid image is loaded on the
device.
Trap Severity Level: Major."
::= { oriImageTraps 0 2 }
oriTrapImageTooLarge NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is generated when the image loaded on the device
exceeds the size limitation of flash.
Trap Severity Level: Major."
::= { oriImageTraps 0 3 }
oriTrapIncompatibleImage NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is generated when an incompatible image is loaded on
the device.
Trap Severity Level: Major."
::= { oriImageTraps 0 4 }
oriTrapInvalidImageDigitalSignature NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is generated when an image with an invalid Digital
Signature is loaded in the device.
Trap Severity Level: Major."
::= { oriImageTraps 0 5 }
--=============================================================================
-- The WORP Related Trap Group: oriWORPTraps
--=============================================================================
oriWORPTraps OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This is the WORP related trap group."
::= { orinocoTrap 11 }
oriWORPStationRegister NOTIFICATION-TYPE
OBJECTS { oriTrapVarInterface, oriTrapVarMACAddress }
STATUS current
DESCRIPTION
"This trap is generated when a WORP satellite has registered on
and interface of a base; a satellite will not generate this trap,
but use oriWORPLinkUp instead. For the station indicated, the
oriStationStatTableOperStatus will be up.
Trap Severity Level: Informational."
::= { oriWORPTraps 0 1 }
oriWORPStationDeRegister NOTIFICATION-TYPE
OBJECTS { oriTrapVarInterface, oriTrapVarMACAddress }
STATUS current
DESCRIPTION
"This trap is generated when a WORP satellite has been deleted
from an interface of a base; a satellite will not generate this
trap, but use oriWORPLinkDown instead. For the station indicated,
the oriStationStatTableOperStatus will be down.
Trap Severity Level: Informational."
::= { oriWORPTraps 0 2 }
--=============================================================================
-- The System Feature based License Related Trap Group: oriSysFeatureTraps
--=============================================================================
oriSysFeatureTraps OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This is the System Feature based License related trap group."
::= { orinocoTrap 12 }
oriTrapIncompatibleLicenseFile NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable }
STATUS current
DESCRIPTION
"This trap is generated when a license file in the device's flash
memory is not compatible with the current bootloader.
Trap Severity Level: Major."
::= { oriSysFeatureTraps 0 1 }
oriTrapFeatureNotSupported NOTIFICATION-TYPE
OBJECTS { oriSystemFeatureTableCode }
STATUS current
DESCRIPTION
"This trap is generated when a feature present in the license
codes is not supported by the current embedded software image.
A newer embedded software image could support the feature or
there are more license that needed.
Trap Severity Level: Informational."
::= { oriSysFeatureTraps 0 2 }
oriTrapZeroLicenseFiles NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is generated when a single license file is not present
in flash. This causes the device to operate in default mode
with very limited features enabled.
Trap Severity Level: Critical."
::= { oriSysFeatureTraps 0 3 }
oriTrapInvalidLicenseFile NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable }
STATUS current
DESCRIPTION
"This trap is generated when a license file in the device's flash
memory has an invalid signature and will be ignored.
Trap Severity Level: Minor."
::= { oriSysFeatureTraps 0 4 }
oriTrapUselessLicense NOTIFICATION-TYPE
OBJECTS { oriGenericTrapVariable }
STATUS current
DESCRIPTION
"This trap is generated when a license code file does not contain
any valid feature code. The probably reason for this is that
after verification, not any of the features was meant for this
units MAC address.
Trap Severity Level: Informational."
::= { oriSysFeatureTraps 0 5 }
--=============================================================================
-- ORiNOCO MIBs End
--=============================================================================
END