2129 lines
70 KiB
Plaintext
2129 lines
70 KiB
Plaintext
|
|
-- File Name : LIGHTPAD-MIB.mib
|
|
-- Date : Thu Mar 31 16:01:25 BRST 2009
|
|
-- Author : AdventNet Agent Toolkit Java Edition - MIB Editor 6
|
|
-- Authors : Marcelo Uesono <uesono@padtec.com.br>, Lavoisier J.L.Farias <lavoisier@padtec.com.br>, Thiago Ribeiro Mendes <thiago.mendes@padtec.com.br>, Daniel Araujo <daniel@padtec.com.br>, Denis Neves <dsantos@padtec.com.br>
|
|
-- This MIB was changed at September 10th-2008 in order to add the field boarModel for the following traps: alarmStartNotification, alarmEndNotification, alarmAckNotification, eventNotification
|
|
-- This MIB was changed at September 22nd-2008 in order to remove the fields alarmAckDate, alarmAckUser, alarmAckDescription for the following traps: alarmStartNotification and alarmEndNotification
|
|
-- This MIB was updated at January 2009 to provide Network Management System alarms and information. The following tables were added: circuitTrailTable, networkAlarmTable, otsTrailTable and omsTrailTable. The following notification were added: networkAlarmStartNotification, networkAlarmEndNotification and networkAlarmAckNotification. When a trail is removed at the Management System, the current alarms of this trail are ended.
|
|
-- This MIB was changed at January 22nd-2009 in order to add the fields networkAlarmNeNameSource, networkAlarmBoardNameSource, networkAlarmPortNameSource, networkAlarmNeNameDestination, networkAlarmBoardNameDestination, and networkAlarmPortNameDestination to the networkAlarmTable, networkAlarmStartNotification, and networkAlarmEndNotification.
|
|
-- This MIB was changed at March 31st-2009 to support estimated BER Metric
|
|
-- This MIB was changed at April 23rd-2009 to include the networkAlarmChangeNotification
|
|
-- This MIB was changed at May 12th-2009 to include the field boardState in boardTable and new eventType: boardInOperation ( 4 ) and boardInTest ( 5 )
|
|
-- This MIB was changed at Sep 16th-2010 to add new types of performance
|
|
-- This MIB was changed at Aug 28th-2014 to add table boardPerformanceTable (but was only used in v3_13_1_20140114_patchs_GERLP881)
|
|
-- This MIB was updated at Jun 30th-2015 to add field alarmId for the following traps: alarmStartNotification, alarmEndNotification and alarmAckNotification
|
|
-- This MIB was updated at Jul 07th-2015 to add comment about alarmId not is sent when parameter -DsendalarmId as value false.
|
|
-- This MIB was updated at Jan 02nd-2017 to add table trailAssociationTable relation OtsId between OmsId.
|
|
-- This MIB was updated at Jan 02nd-2017 to add table circuitAssociationOmsTable relation CircuitId between OmsId.
|
|
-- This MIB was changed at Aug 03rd-2018 to use table boardPerformanceTable to fix SNIV-69 (Fixed OID for board performance measures)
|
|
-- This MIB was changed at Jul 15rd-2020 Refactoring to RFC-2580 compliance.
|
|
|
|
METROPAD3 DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
RowStatus, DateAndTime, TruthValue
|
|
FROM SNMPv2-TC
|
|
snmp
|
|
FROM RFC1213-MIB
|
|
enterprises, MODULE-IDENTITY, OBJECT-TYPE, Integer32, NOTIFICATION-TYPE, TimeTicks, IpAddress
|
|
FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF;
|
|
|
|
moduleIdentity MODULE-IDENTITY
|
|
LAST-UPDATED "200904231617Z"
|
|
ORGANIZATION "Padtec S/A http://www.padtec.com.br"
|
|
CONTACT-INFO "SAC: sac@padtec.com.br"
|
|
DESCRIPTION "This Module is responsible to map all the Padtec Manageable Equipment to SNMP."
|
|
REVISION "200904231617Z"
|
|
DESCRIPTION "This Revision contais the NMS capabilities."
|
|
::= { enterprises 1 }
|
|
|
|
org OBJECT IDENTIFIER
|
|
::= { iso 3 }
|
|
|
|
dod OBJECT IDENTIFIER
|
|
::= { org 6 }
|
|
|
|
internet OBJECT IDENTIFIER
|
|
::= { dod 1 }
|
|
|
|
private OBJECT IDENTIFIER
|
|
::= { internet 4 }
|
|
|
|
enterprises OBJECT IDENTIFIER
|
|
::= { private 1 }
|
|
|
|
padtec OBJECT IDENTIFIER
|
|
::= { enterprises 14846 }
|
|
|
|
metropad3 OBJECT IDENTIFIER
|
|
::= { padtec 3 }
|
|
|
|
lightpadMIBGroups OBJECT IDENTIFIER ::= { moduleIdentity 1 }
|
|
|
|
neTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Contains all the Network Elements which were associated at the Management System. A network element at Padtec platform is a supervisor unit that manages a bundle of boards and has a network transport function at the network."
|
|
::= { metropad3 1 }
|
|
|
|
neEntry OBJECT-TYPE
|
|
SYNTAX NeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The Network Element."
|
|
INDEX { neId }
|
|
::= { neTable 1 }
|
|
|
|
NeEntry ::= SEQUENCE {
|
|
neId Integer32,
|
|
neName OCTET STRING,
|
|
neNetwork OCTET STRING,
|
|
neMap OCTET STRING,
|
|
neRowStatus RowStatus
|
|
}
|
|
|
|
|
|
neId OBJECT-TYPE
|
|
SYNTAX Integer32 ( 1 .. 2147483647 )
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "It is a unique ID to identifiy a row of this table."
|
|
::= { neEntry 1 }
|
|
|
|
|
|
neName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is an unique identifier that describes the Name of Network Element. At Padtec system, this name is unique and duplication are not allowed."
|
|
::= { neEntry 2 }
|
|
|
|
|
|
neNetwork OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It describes the network or system which contains the current NE Name."
|
|
::= { neEntry 3 }
|
|
|
|
|
|
neMap OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It describes the map which contains the current NE Name."
|
|
::= { neEntry 4 }
|
|
|
|
|
|
neRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The RowStatus of this entry."
|
|
::= { neEntry 5 }
|
|
|
|
boardTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BoardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Contains all boards managed by Padtec Network Management System."
|
|
::= { metropad3 2 }
|
|
|
|
boardEntry OBJECT-TYPE
|
|
SYNTAX BoardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The managed board."
|
|
INDEX { boardId }
|
|
::= { boardTable 1 }
|
|
|
|
BoardEntry ::= SEQUENCE {
|
|
boardId Integer32,
|
|
boardPart Integer32,
|
|
boardSerial Integer32,
|
|
boardModel OCTET STRING,
|
|
boardName OCTET STRING,
|
|
boardDescription OCTET STRING,
|
|
boardSubRack Integer32,
|
|
boardSlot Integer32,
|
|
boardVersion OCTET STRING,
|
|
boardNeName OCTET STRING,
|
|
boardNeMap OCTET STRING,
|
|
boardState INTEGER,
|
|
boardRowStatus RowStatus,
|
|
boardRackPosition Integer32
|
|
}
|
|
|
|
|
|
boardId OBJECT-TYPE
|
|
SYNTAX Integer32 ( 1 .. 2147483647 )
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "It is a unique ID to identifiy a row of this table."
|
|
::= { boardEntry 1 }
|
|
|
|
|
|
boardPart OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the part number which defines the model of Padtec board which is being managed."
|
|
::= { boardEntry 2 }
|
|
|
|
|
|
boardSerial OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the serial number which defines the serial number of determined model of Padtec board which is being managed."
|
|
::= { boardEntry 3 }
|
|
|
|
|
|
boardModel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the model name of the Padtec board which is being managed."
|
|
::= { boardEntry 4 }
|
|
|
|
|
|
boardName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the name defined by the user of Padtec Network Management System."
|
|
::= { boardEntry 5 }
|
|
|
|
|
|
boardDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to the description fullfilled by the user of Padtec Network Management System."
|
|
::= { boardEntry 6 }
|
|
|
|
|
|
boardRackPosition OBJECT-TYPE
|
|
SYNTAX Integer32 ( 0 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the number of rack position on which the board of correspondent entry is placed."
|
|
::= { boardEntry 14 }
|
|
|
|
|
|
boardSubRack OBJECT-TYPE
|
|
SYNTAX Integer32 ( 0 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the number of sub-rack on which the board of correspondent entry is placed."
|
|
::= { boardEntry 7 }
|
|
|
|
|
|
boardSlot OBJECT-TYPE
|
|
SYNTAX Integer32 ( 0 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the number of slot on which the board of correspondent entry is placed."
|
|
::= { boardEntry 8 }
|
|
|
|
|
|
boardVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the board Version"
|
|
::= { boardEntry 9 }
|
|
|
|
|
|
boardNeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the name of NE which the correspondent board entry is placed."
|
|
::= { boardEntry 10 }
|
|
|
|
|
|
boardNeMap OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It describes the map which contains the current NE Name."
|
|
::= { boardEntry 11 }
|
|
|
|
boardState OBJECT-TYPE
|
|
SYNTAX INTEGER { operation ( 1 ) , test ( 2 ) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It identifies the state of the board."
|
|
::= { boardEntry 12 }
|
|
|
|
|
|
boardRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The RowStatus of this entry."
|
|
::= { boardEntry 13 }
|
|
|
|
alarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Contains all the alarms which are raised by Padtec Network Management System. This table does NOT have events."
|
|
::= { metropad3 3 }
|
|
|
|
alarmEntry OBJECT-TYPE
|
|
SYNTAX AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The alarm at Padtec Network Management System."
|
|
INDEX { alarmId }
|
|
::= { alarmTable 1 }
|
|
|
|
AlarmEntry ::= SEQUENCE {
|
|
alarmId Integer32,
|
|
alarmType Integer32,
|
|
alarmSeverity INTEGER,
|
|
alarmName OCTET STRING,
|
|
alarmBoardPart Integer32,
|
|
alarmBoardSerial Integer32,
|
|
alarmBoardSubRack Integer32,
|
|
alarmBoardSlot Integer32,
|
|
alarmStart DateAndTime,
|
|
alarmEnd DateAndTime,
|
|
alarmAckDate DateAndTime,
|
|
alarmAckDescription OCTET STRING,
|
|
alarmAckUser OCTET STRING,
|
|
alarmNeName OCTET STRING,
|
|
alarmNeMap OCTET STRING,
|
|
alarmRowStatus RowStatus,
|
|
alarmBoardRackPosition Integer32,
|
|
alarmResource OCTET STRING
|
|
}
|
|
|
|
|
|
alarmId OBJECT-TYPE
|
|
SYNTAX Integer32 ( 1 .. 2147483647 )
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "It is a unique ID to identifiy a row of this table."
|
|
::= { alarmEntry 1 }
|
|
|
|
|
|
alarmType OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is an integer which describes in a unique manner the alarm at Padtec Network Management System. Different types of boards have different numbers of alarmTypes. For instance, the LOS Alarm has an identifier for the Board amplifier, and has a different one for the OTN trasponder board."
|
|
::= { alarmEntry 2 }
|
|
|
|
|
|
alarmSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER { clear ( 1 ) , warning ( 2 ) , minor ( 3 ) , major ( 4 ) , critical ( 5 ) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It identifies the severity of each alarm."
|
|
::= { alarmEntry 3 }
|
|
|
|
|
|
alarmName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is a text that describes the name of the corresponding alarm. It has the same text as viewed by the user of Padtec Network Management System."
|
|
::= { alarmEntry 4 }
|
|
|
|
|
|
alarmBoardPart OBJECT-TYPE
|
|
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is a number corresponding to the part number at the boardTable. Every alarm has to have a associated board identified at boardTable."
|
|
::= { alarmEntry 5 }
|
|
|
|
|
|
alarmBoardSerial OBJECT-TYPE
|
|
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is a number corresponding to the serial number at the boardTable. Every alarm has to have a associated board identified at boardTable."
|
|
::= { alarmEntry 6 }
|
|
|
|
|
|
alarmBoardRackPosition OBJECT-TYPE
|
|
SYNTAX Integer32 ( 0 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the number of rack position on which the board of correspondent entry is placed."
|
|
::= { alarmEntry 17 }
|
|
|
|
|
|
alarmResource OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is a text that describes the name of the corresponding alarm. It has the same text as viewed by the user of Padtec Network Management System."
|
|
::= { alarmEntry 18 }
|
|
|
|
|
|
alarmBoardSubRack OBJECT-TYPE
|
|
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the number of sub-rack on which the board of correspondent entry is placed."
|
|
::= { alarmEntry 7 }
|
|
|
|
|
|
alarmBoardSlot OBJECT-TYPE
|
|
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the number of slot on which the board of correspondent entry is placed."
|
|
::= { alarmEntry 8 }
|
|
|
|
|
|
alarmStart OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the Date and Time when the alarm started, .i.e.,the date and time when the alarm was raised."
|
|
::= { alarmEntry 9 }
|
|
|
|
|
|
alarmEnd OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the Date and Time when the alarm ended, .i.e.,the date and time when the alarm was ended. All active alarms have this field as an empty value."
|
|
::= { alarmEntry 10 }
|
|
|
|
|
|
alarmAckDate OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the Date and Time when the alarm was acknowledged."
|
|
::= { alarmEntry 11 }
|
|
|
|
|
|
alarmAckDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the description corresponding to the text inputed by the user of Padtec Network Management System, or by anotehr NMS that acknowledge the corresponding alarm."
|
|
::= { alarmEntry 12 }
|
|
|
|
|
|
alarmAckUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the name of the user that acknowledged the alarm of Padtec Network Management System. If the alarm was acknowledged by another NMS, so this field will have the value equals to the word NMS."
|
|
::= { alarmEntry 13 }
|
|
|
|
|
|
alarmNeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the name of Network Element at neTable on which the event has been identified."
|
|
::= { alarmEntry 14 }
|
|
|
|
|
|
alarmNeMap OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It describes the map which contains the current NE Name."
|
|
::= { alarmEntry 15 }
|
|
|
|
|
|
alarmRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The RowStatus of this entry."
|
|
::= { alarmEntry 16 }
|
|
|
|
eventTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EventEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Contains all the events which are raised by Padtec Network Management System. This table does NOT have alarms. So, all the commands sent to the boards are registered at this table."
|
|
::= { metropad3 4 }
|
|
|
|
eventEntry OBJECT-TYPE
|
|
SYNTAX EventEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The event which is raised by Padtec Network Management System."
|
|
INDEX { eventId }
|
|
::= { eventTable 1 }
|
|
|
|
EventEntry ::= SEQUENCE {
|
|
eventId Integer32,
|
|
eventType INTEGER,
|
|
eventName OCTET STRING,
|
|
eventBoardPart Integer32,
|
|
eventBoardSerial Integer32,
|
|
eventBoardSubRack Integer32,
|
|
eventBoardSlot Integer32,
|
|
eventTime DateAndTime,
|
|
eventNeName OCTET STRING,
|
|
eventNeMap OCTET STRING,
|
|
eventRowStatus RowStatus,
|
|
eventBoardRackPosition Integer32
|
|
}
|
|
|
|
|
|
eventId OBJECT-TYPE
|
|
SYNTAX Integer32 ( 1 .. 2147483647 )
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "It is a unique ID to identifiy a row of this table."
|
|
::= { eventEntry 1 }
|
|
|
|
|
|
eventType OBJECT-TYPE
|
|
SYNTAX INTEGER { newNe ( 0 ) , removeNe ( 1 ) , newBoard ( 2 ) , removeBoard ( 3 ) , boardInOperation ( 4 ) , boardInTest ( 5 ), updateNE (6) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is an integer which describes in a unique manner the event at Padtec Network Management System."
|
|
::= { eventEntry 2 }
|
|
|
|
|
|
eventName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is a text that describes the name of the corresponding event. It has the same text as viewed by the user of Padtec Network Management System."
|
|
::= { eventEntry 3 }
|
|
|
|
|
|
eventBoardPart OBJECT-TYPE
|
|
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is a number corresponding to the part number at the boardTable. Every event has to have a associated board identified at boardTable."
|
|
::= { eventEntry 4 }
|
|
|
|
|
|
eventBoardSerial OBJECT-TYPE
|
|
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is a number corresponding to the serial number at the boardTable. Every event has to have a associated board identified at boardTable."
|
|
::= { eventEntry 5 }
|
|
|
|
eventBoardRackPosition OBJECT-TYPE
|
|
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the number of rack position on which the board of correspondent entry is placed."
|
|
::= { eventEntry 12 }
|
|
|
|
|
|
eventBoardSubRack OBJECT-TYPE
|
|
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the number of sub-rack on which the board of correspondent entry is placed."
|
|
::= { eventEntry 6 }
|
|
|
|
|
|
eventBoardSlot OBJECT-TYPE
|
|
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the number of slot on which the board of correspondent entry is placed."
|
|
::= { eventEntry 7 }
|
|
|
|
|
|
eventTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the Date and Time when the event happen."
|
|
::= { eventEntry 8 }
|
|
|
|
|
|
eventNeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the name of Network Element at NE Table on which the event has been identified."
|
|
::= { eventEntry 9 }
|
|
|
|
|
|
eventNeMap OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It describes the map which contains the current NE Name."
|
|
::= { eventEntry 10 }
|
|
|
|
|
|
eventRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The RowStatus of this entry."
|
|
::= { eventEntry 11 }
|
|
|
|
performanceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PerformanceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Contains all the measurements which are stored by Padtec Network Management System. "
|
|
::= { metropad3 5 }
|
|
|
|
performanceEntry OBJECT-TYPE
|
|
SYNTAX PerformanceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A performance measure stored by Padtec Network Management System."
|
|
INDEX { performanceId }
|
|
::= { performanceTable 1 }
|
|
|
|
PerformanceEntry ::= SEQUENCE {
|
|
performanceId Integer32,
|
|
performanceBoardPart Integer32,
|
|
performanceBoardSerial Integer32,
|
|
performanceType INTEGER,
|
|
performancePortType INTEGER,
|
|
performancePortNumber Integer32,
|
|
performanceValue Integer32,
|
|
performanceRate OCTET STRING,
|
|
performanceTime DateAndTime,
|
|
performanceNeName OCTET STRING,
|
|
performanceNeMap OCTET STRING,
|
|
performanceRowStatus RowStatus,
|
|
performanceOid Integer32
|
|
|
|
}
|
|
|
|
|
|
performanceId OBJECT-TYPE
|
|
SYNTAX Integer32 ( 1 .. 2147483647 )
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "It is a unique ID to identifiy a row of this table."
|
|
::= { performanceEntry 1 }
|
|
|
|
|
|
performanceBoardPart OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is a number corresponding to the part number at the boardTable. Every performance measurement is associated with a board identified at boardTable."
|
|
::= { performanceEntry 2 }
|
|
|
|
|
|
performanceBoardSerial OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is a number corresponding to the serial number at the boardTable. Every performance measurement is associated with a board identified at boardTable."
|
|
::= { performanceEntry 3 }
|
|
|
|
|
|
performanceType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to the type of the performance measurement has been taken. See the list of types at the manual."
|
|
::= { performanceEntry 5 }
|
|
|
|
|
|
performancePortType OBJECT-TYPE
|
|
SYNTAX INTEGER { client ( 1 ) , wdm ( 2 ) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to the type of port of the Padtec Board on which the performance measurement has been taken."
|
|
::= { performanceEntry 6 }
|
|
|
|
|
|
performancePortNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It corresponds the port number of the Padtec Board on which the performance measurenebt has been taken."
|
|
::= { performanceEntry 7 }
|
|
|
|
|
|
performanceValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to the performance measurements multipled by 100, in such way that is possible to represent measurements with 2 number precisions. For instance, if the value is 12.25 dBm, then the corresponding value at this table will be 1225."
|
|
::= { performanceEntry 8 }
|
|
|
|
|
|
performanceRate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It describes the performance measurements which are displayed at scientific notation. Therefore, all the error rates, transmission rates are mapped at this column."
|
|
::= { performanceEntry 9 }
|
|
|
|
|
|
performanceTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to the Date and Time when the performance measurement was stored by the Padtec Network Management System."
|
|
::= { performanceEntry 10 }
|
|
|
|
|
|
performanceNeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the name of NE which the correspondent board entry is placed."
|
|
::= { performanceEntry 11 }
|
|
|
|
|
|
performanceNeMap OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It describes the map which contains the current NE Name."
|
|
::= { performanceEntry 12 }
|
|
|
|
performanceOid OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is a number corresponding to the part number at the boardTable. Every performance measurement is associated with a board identified at boardTable."
|
|
::= { performanceEntry 14 }
|
|
|
|
|
|
performanceRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The RowStatus of this entry."
|
|
::= { performanceEntry 13 }
|
|
|
|
|
|
|
|
serverStatus OBJECT IDENTIFIER
|
|
::= { metropad3 6 }
|
|
|
|
alarmStartNotification NOTIFICATION-TYPE
|
|
OBJECTS { alarmName, alarmBoardPart, alarmBoardSerial, alarmBoardRackPosition, alarmBoardSlot, alarmBoardSubRack, alarmNeName, alarmNeMap, alarmType, alarmSeverity, alarmStart, alarmRowStatus, boardModel, alarmId }
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to a notification when an alarm is raised. alarmId not is sent when parameter -DsendalarmId as value false."
|
|
::= { metropad3 7 }
|
|
|
|
alarmEndNotification NOTIFICATION-TYPE
|
|
OBJECTS { alarmName, alarmBoardPart, alarmBoardSerial, alarmBoardRackPosition, alarmBoardSlot, alarmBoardSubRack, alarmNeName, alarmNeMap, alarmType, alarmSeverity, alarmEnd, alarmRowStatus, boardModel, alarmId }
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to a notification when an alarm is terminated. obs alarmId not is sent when parameter -DsendalarmId as value false."
|
|
::= { metropad3 8 }
|
|
|
|
alarmAckNotification NOTIFICATION-TYPE
|
|
OBJECTS { alarmName, alarmBoardPart, alarmBoardSerial, alarmBoardRackPosition, alarmBoardSlot, alarmBoardSubRack, alarmNeName, alarmNeMap, alarmType, alarmSeverity, alarmStart, alarmEnd, alarmAckDate, alarmAckUser, alarmAckDescription, alarmRowStatus, boardModel, alarmId }
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to a notification when an alarm is acknowledge. obs alarmId not is sent when parameter -DsendalarmId as value false."
|
|
::= { metropad3 9 }
|
|
|
|
eventNotification NOTIFICATION-TYPE
|
|
OBJECTS { eventName, eventBoardPart, eventBoardSerial, eventBoardRackPosition, eventBoardSlot, eventBoardSubRack, eventNeName, eventNeMap, eventType, eventTime, eventRowStatus, boardModel }
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to a notification when an event happen."
|
|
::= { metropad3 10 }
|
|
|
|
|
|
isAliveNotification NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to a notification to show system is still alive."
|
|
::= { metropad3 11 }
|
|
|
|
isRecreateAlarmsNotification NOTIFICATION-TYPE
|
|
OBJECTS { alarmsNotificationBoardPart, alarmsNotificationBoardSerial, alarmsNotificationBoardName, alarmsNotificationNeName }
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to a notification to recreate Alarmes"
|
|
::= { metropad3 24 }
|
|
|
|
isStatusNotification NOTIFICATION-TYPE
|
|
OBJECTS { statusAgente, uptimeAgente }
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to a notification to show system is still alive."
|
|
::= { metropad3 25 }
|
|
|
|
|
|
statusAgente OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is a text that describes the name of the corresponding event. It has the same text as viewed by the user of Padtec Network Management System."
|
|
::= { isStatusNotification 1 }
|
|
|
|
uptimeAgente OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is a text that describes the name of the corresponding event. It has the same text as viewed by the user of Padtec Network Management System."
|
|
::= { isStatusNotification 2 }
|
|
|
|
alarmsNotificationBoardPart OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is a text that describes the name of the corresponding event. It has the same text as viewed by the user of Padtec Network Management System."
|
|
::= { isRecreateAlarmsNotification 1 }
|
|
|
|
|
|
alarmsNotificationBoardSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is a text that describes the name of the corresponding event. It has the same text as viewed by the user of Padtec Network Management System."
|
|
::= { isRecreateAlarmsNotification 2 }
|
|
|
|
alarmsNotificationBoardName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is a text that describes the name of the corresponding event. It has the same text as viewed by the user of Padtec Network Management System."
|
|
::= { isRecreateAlarmsNotification 3 }
|
|
|
|
|
|
alarmsNotificationNeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is a text that describes the name of the corresponding event. It has the same text as viewed by the user of Padtec Network Management System."
|
|
::= { isRecreateAlarmsNotification 4 }
|
|
|
|
networkAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NetworkAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Contains the Padtec Network Management System alarms. This table does NOT have system events (see eventTable) neither EMS alarms (see alarmTable)."
|
|
::= { metropad3 12 }
|
|
|
|
networkAlarmEntry OBJECT-TYPE
|
|
SYNTAX NetworkAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The Padtec Network Management System alarms."
|
|
INDEX { networkAlarmId }
|
|
::= { networkAlarmTable 1 }
|
|
|
|
NetworkAlarmEntry ::= SEQUENCE {
|
|
networkAlarmId Integer32,
|
|
networkAlarmSeverity INTEGER,
|
|
networkAlarmKey Integer32,
|
|
networkAlarmGroup INTEGER,
|
|
networkAlarmStart DateAndTime,
|
|
networkAlarmEnd DateAndTime,
|
|
networkAlarmNetworkName OCTET STRING,
|
|
networkAlarmResource OCTET STRING,
|
|
networkAlarmLayer INTEGER,
|
|
networkAlarmNeName OCTET STRING,
|
|
networkAlarmBoardName OCTET STRING,
|
|
networkAlarmName OCTET STRING,
|
|
networkAlarmType INTEGER,
|
|
networkAlarmNeNameSource OCTET STRING,
|
|
networkAlarmBoardNameSource OCTET STRING,
|
|
networkAlarmPortNameSource OCTET STRING,
|
|
networkAlarmNeNameDestination OCTET STRING,
|
|
networkAlarmBoardNameDestination OCTET STRING,
|
|
networkAlarmPortNameDestination OCTET STRING,
|
|
networkAlarmAck TruthValue,
|
|
networkAlarmAckDate DateAndTime,
|
|
networkAlarmAckUser OCTET STRING,
|
|
networkAlarmRowStatus RowStatus
|
|
}
|
|
|
|
|
|
networkAlarmId OBJECT-TYPE
|
|
SYNTAX Integer32 ( 1 .. 2147483647 )
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "It is a unique ID to identifiy a row of this table."
|
|
::= { networkAlarmEntry 1 }
|
|
|
|
|
|
networkAlarmSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER { indeterminated ( 0 ) , clear ( 1 ) , warning ( 2 ) , minor ( 3 ) , major ( 4 ) , critical ( 5 ) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It identifies the severity of each alarm."
|
|
::= { networkAlarmEntry 2 }
|
|
|
|
|
|
networkAlarmKey OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is an integer which describes in a unique manner the alarm at Padtec Network Management System."
|
|
::= { networkAlarmEntry 3 }
|
|
|
|
|
|
networkAlarmGroup OBJECT-TYPE
|
|
SYNTAX INTEGER { communicationsAlarm ( 2 ) , environmentalAlarm ( 3 ) , equipmentAlarm ( 4 ) , processingErrorAlarm ( 10 ) , qualityOfServiceAlarm ( 11 ) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The category of this alarm as defined by CCITT Recommendation X.733."
|
|
::= { networkAlarmEntry 4 }
|
|
|
|
|
|
networkAlarmStart OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the Date and Time when the alarm started, .i.e.,the date and time when the event happened."
|
|
::= { networkAlarmEntry 5 }
|
|
|
|
|
|
networkAlarmEnd OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the Date and Time when the alarm ended. All active (not cleared ones) alarms show the value 1969-12-31,22:0:0.0,-3:0."
|
|
::= { networkAlarmEntry 6 }
|
|
|
|
|
|
networkAlarmNetworkName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the network affected by the alarm."
|
|
::= { networkAlarmEntry 7 }
|
|
|
|
|
|
networkAlarmResource OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the affected trail or circuit."
|
|
::= { networkAlarmEntry 8 }
|
|
|
|
|
|
networkAlarmLayer OBJECT-TYPE
|
|
SYNTAX INTEGER { ots ( 1 ) , oms ( 2 ) , circuit ( 3 ) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The Layer of the alarm: tranport (1), multiplex (2) or end-to-end (3)."
|
|
::= { networkAlarmEntry 9 }
|
|
|
|
|
|
networkAlarmNeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the name of Network Element at NE Table on which the event has been identified."
|
|
::= { networkAlarmEntry 10 }
|
|
|
|
|
|
networkAlarmBoardName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the affected board."
|
|
::= { networkAlarmEntry 11 }
|
|
|
|
|
|
networkAlarmName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is a text that describes the name of the corresponding alarm. It has the same text as viewed by the user of Padtec Network Management System."
|
|
::= { networkAlarmEntry 12 }
|
|
|
|
|
|
networkAlarmType OBJECT-TYPE
|
|
SYNTAX INTEGER { ots ( 1 ) , otsClient ( 2 ) , och ( 3 ) , circuit ( 4 ) , oam ( 5 ) , otn25G ( 6 ) , otu1 ( 7 ) , odu1 ( 8 ) , sdh ( 9 ) , otn10G ( 10 ) , otu2 ( 11 ) , odu2 ( 12 ) , opu2 ( 13 ) , equipment ( 14 ) , management ( 15 ) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Shows the kind of this network alarm."
|
|
::= { networkAlarmEntry 13 }
|
|
|
|
networkAlarmNeNameSource OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the source NE of the affected trail or circuit."
|
|
::= { networkAlarmEntry 14 }
|
|
|
|
networkAlarmBoardNameSource OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the source board of the affected trail or circuit."
|
|
::= { networkAlarmEntry 15 }
|
|
|
|
networkAlarmPortNameSource OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the source port/interface of the affected trail or circuit."
|
|
::= { networkAlarmEntry 16 }
|
|
|
|
networkAlarmNeNameDestination OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the destination NE of the affected trail or circuit."
|
|
::= { networkAlarmEntry 17 }
|
|
|
|
networkAlarmBoardNameDestination OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the destination board of the affected trail or circuit."
|
|
::= { networkAlarmEntry 18 }
|
|
|
|
networkAlarmPortNameDestination OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the destination port/interface of the affected trail or circuit."
|
|
::= { networkAlarmEntry 19 }
|
|
|
|
|
|
networkAlarmAck OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Identifies if the alarm was acknowledged. This object has the value 'true(1)', if this alarm was acknowledged and the value 'false(2)' otherwise."
|
|
::= { networkAlarmEntry 20 }
|
|
|
|
|
|
networkAlarmAckDate OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the Date and Time when the alarm was acknowledged or 1969-12-31,22:0:0.0,-3:0 for alarms not acknowledged."
|
|
::= { networkAlarmEntry 21 }
|
|
|
|
|
|
networkAlarmAckUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the name of the user that acknowledged the alarm of Padtec Network Management System. If the alarm was acknowledged by another NMS, so this field will have the value equals to the word NMS. This field will have the value equals to the word N/A if the corresponding alarm was not acknowledged."
|
|
::= { networkAlarmEntry 22 }
|
|
|
|
|
|
networkAlarmRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The RowStatus of this entry."
|
|
::= { networkAlarmEntry 23 }
|
|
|
|
otsTrailTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OtsTrailEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Contains all OTS trails."
|
|
::= { metropad3 13 }
|
|
|
|
otsTrailEntry OBJECT-TYPE
|
|
SYNTAX OtsTrailEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The OTS Trail."
|
|
INDEX { otsTrailId }
|
|
::= { otsTrailTable 1 }
|
|
|
|
OtsTrailEntry ::= SEQUENCE {
|
|
otsTrailId Integer32,
|
|
otsTrailName OCTET STRING,
|
|
otsTrailDescription OCTET STRING,
|
|
otsTrailFiberType OCTET STRING,
|
|
otsTrailDistance Integer32,
|
|
otsTrailSourceNE OCTET STRING,
|
|
otsTrailSourceBoard OCTET STRING,
|
|
otsTrailSourcePort OCTET STRING,
|
|
otsTrailDestinationNE OCTET STRING,
|
|
otsTrailDestinationBoard OCTET STRING,
|
|
otsTrailDestinationPort OCTET STRING,
|
|
otsTrailDatabaseId Integer32,
|
|
otsTrailRowStatus RowStatus
|
|
}
|
|
|
|
|
|
otsTrailId OBJECT-TYPE
|
|
SYNTAX Integer32 ( 1 .. 2147483647 )
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "It is a unique ID to identifiy a row of this table."
|
|
::= { otsTrailEntry 1 }
|
|
|
|
otsTrailName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this trail OTS."
|
|
::= { otsTrailEntry 2 }
|
|
|
|
|
|
otsTrailDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The description of this trail OTS."
|
|
::= { otsTrailEntry 3 }
|
|
|
|
|
|
otsTrailFiberType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The type of optical fiber."
|
|
::= { otsTrailEntry 4 }
|
|
|
|
otsTrailDistance OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The distance of this OTS Trail in kilometers multipled by 100, in such way that is possible to represent measurements with 2 number precisions. For instance, if the value is 90.25 km, then the corresponding value at this table will be 9025."
|
|
::= { otsTrailEntry 5 }
|
|
|
|
|
|
otsTrailSourceNE OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this OTS trail's source NE. See neTable."
|
|
::= { otsTrailEntry 6 }
|
|
|
|
|
|
otsTrailSourceBoard OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this OTS trail's source board. See boardTable."
|
|
::= { otsTrailEntry 7 }
|
|
|
|
|
|
otsTrailSourcePort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this OTS trail's source port/interface."
|
|
::= { otsTrailEntry 8 }
|
|
|
|
|
|
otsTrailDestinationNE OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this OTS trail's destination NE. See neTable."
|
|
::= { otsTrailEntry 9 }
|
|
|
|
|
|
otsTrailDestinationBoard OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this OTS trail's destination board. See boardTable."
|
|
::= { otsTrailEntry 10 }
|
|
|
|
|
|
otsTrailDestinationPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this OTS trail's destination port/interface."
|
|
::= { otsTrailEntry 11 }
|
|
|
|
otsTrailDatabaseId OBJECT-TYPE
|
|
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is a unique ID to identifiy a row of this table. The id's negatives represents back path."
|
|
::= { otsTrailEntry 12 }
|
|
|
|
|
|
otsTrailRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The RowStatus of this entry."
|
|
::= { otsTrailEntry 13 }
|
|
|
|
omsTrailTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OmsTrailEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Contains all Optical Multiplex Section (OMS) Trails."
|
|
::= { metropad3 14 }
|
|
|
|
omsTrailEntry OBJECT-TYPE
|
|
SYNTAX OmsTrailEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The Optical Multiplex Section (OMS)."
|
|
INDEX { omsTrailId }
|
|
::= { omsTrailTable 1 }
|
|
|
|
OmsTrailEntry ::= SEQUENCE {
|
|
omsTrailId Integer32,
|
|
omsTrailName OCTET STRING,
|
|
omsTrailDescription OCTET STRING,
|
|
omsTrailSourceNE OCTET STRING,
|
|
omsTrailSourceBoard OCTET STRING,
|
|
omsTrailSourcePort OCTET STRING,
|
|
omsTrailDestinationNE OCTET STRING,
|
|
omsTrailDestinationBoard OCTET STRING,
|
|
omsTrailDestinationPort OCTET STRING,
|
|
omsTrailDatabaseId Integer32,
|
|
omsTrailRowStatus RowStatus
|
|
}
|
|
|
|
|
|
omsTrailId OBJECT-TYPE
|
|
SYNTAX Integer32 ( 1 .. 2147483647 )
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "It is a unique ID to identifiy a row of this table."
|
|
::= { omsTrailEntry 1 }
|
|
|
|
|
|
omsTrailName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The identifier of the OMS Trail."
|
|
::= { omsTrailEntry 2 }
|
|
|
|
|
|
omsTrailDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The description of the OMS Trail."
|
|
::= { omsTrailEntry 3 }
|
|
|
|
|
|
omsTrailSourceNE OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this OMS trail's source NE. See neTable."
|
|
::= { omsTrailEntry 4 }
|
|
|
|
|
|
omsTrailSourceBoard OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this OMS trail's source board. See boardTable."
|
|
::= { omsTrailEntry 5 }
|
|
|
|
|
|
omsTrailSourcePort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this OMS trail's source port/interface."
|
|
::= { omsTrailEntry 6 }
|
|
|
|
|
|
omsTrailDestinationNE OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this OMS trail's destination NE. See neTable."
|
|
::= { omsTrailEntry 7 }
|
|
|
|
|
|
omsTrailDestinationBoard OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this OMS trail's destination board. See boardTable."
|
|
::= { omsTrailEntry 8 }
|
|
|
|
|
|
omsTrailDestinationPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this OMS trail's destination port/interface."
|
|
::= { omsTrailEntry 9 }
|
|
|
|
omsTrailDatabaseId OBJECT-TYPE
|
|
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The identifier of the OMS Trail. The id's negatives represents back path."
|
|
::= { omsTrailEntry 10 }
|
|
|
|
|
|
omsTrailRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The RowStatus of this entry."
|
|
::= { omsTrailEntry 11 }
|
|
|
|
circuitTrailTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CircuitTrailEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Contains all circuit end-to-end trails."
|
|
::= { metropad3 15 }
|
|
|
|
circuitTrailEntry OBJECT-TYPE
|
|
SYNTAX CircuitTrailEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The circuit end-to-end trail."
|
|
INDEX { circuitTrailId }
|
|
::= { circuitTrailTable 1 }
|
|
|
|
CircuitTrailEntry ::= SEQUENCE {
|
|
circuitTrailId Integer32,
|
|
circuitTrailName OCTET STRING,
|
|
circuitTrailDescription OCTET STRING,
|
|
circuitTrailClientName OCTET STRING,
|
|
circuitTrailClientId OCTET STRING,
|
|
circuitTrailService OCTET STRING,
|
|
circuitTrailSourceNetwork OCTET STRING,
|
|
circuitTrailSourceNE OCTET STRING,
|
|
circuitTrailSourceBoard OCTET STRING,
|
|
circuitTrailSourcePort OCTET STRING,
|
|
circuitTrailDestinationNetwork OCTET STRING,
|
|
circuitTrailDestinationNE OCTET STRING,
|
|
circuitTrailDestinationBoard OCTET STRING,
|
|
circuitTrailDestinationPort OCTET STRING,
|
|
circuitTrailDatabaseId Integer32,
|
|
circuitTrailRowStatus RowStatus
|
|
}
|
|
|
|
|
|
circuitTrailId OBJECT-TYPE
|
|
SYNTAX Integer32 ( 1 .. 2147483647 )
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "It is a unique ID to identifiy a row of this table."
|
|
::= { circuitTrailEntry 1 }
|
|
|
|
|
|
circuitTrailName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Identifier of the end-to-end circuit."
|
|
::= { circuitTrailEntry 2 }
|
|
|
|
|
|
circuitTrailDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The description of the end-to-end circuit"
|
|
::= { circuitTrailEntry 3 }
|
|
|
|
|
|
circuitTrailClientName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the client of the circuit."
|
|
::= { circuitTrailEntry 4 }
|
|
|
|
|
|
circuitTrailClientId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The identifier of the client of circuit."
|
|
::= { circuitTrailEntry 5 }
|
|
|
|
|
|
circuitTrailService OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The service of the end-to-end circuit."
|
|
::= { circuitTrailEntry 6 }
|
|
|
|
|
|
circuitTrailSourceNetwork OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the circuit's source network."
|
|
::= { circuitTrailEntry 7 }
|
|
|
|
|
|
circuitTrailSourceNE OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this circuit's source NE. See neTable."
|
|
::= { circuitTrailEntry 8 }
|
|
|
|
|
|
circuitTrailSourceBoard OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this circuit's source board. See boardTable."
|
|
::= { circuitTrailEntry 9 }
|
|
|
|
|
|
circuitTrailSourcePort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this circuit's source port/interface."
|
|
::= { circuitTrailEntry 10 }
|
|
|
|
|
|
circuitTrailDestinationNetwork OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this circuit's destination network."
|
|
::= { circuitTrailEntry 11 }
|
|
|
|
|
|
circuitTrailDestinationNE OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this circuit's destination NE. See neTable."
|
|
::= { circuitTrailEntry 12 }
|
|
|
|
|
|
circuitTrailDestinationBoard OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this circuit's destination board. See boardTable."
|
|
::= { circuitTrailEntry 13 }
|
|
|
|
|
|
circuitTrailDestinationPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of this circuit's destination port/interface."
|
|
::= { circuitTrailEntry 14 }
|
|
|
|
circuitTrailDatabaseId OBJECT-TYPE
|
|
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is a unique ID to identifiy a row of this table. The id's negatives represents back path."
|
|
::= { circuitTrailEntry 15 }
|
|
|
|
|
|
|
|
circuitTrailRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The RowStatus of this entry."
|
|
::= { circuitTrailEntry 16 }
|
|
|
|
networkAlarmStartNotification NOTIFICATION-TYPE
|
|
OBJECTS { networkAlarmSeverity, networkAlarmKey, networkAlarmGroup, networkAlarmStart, networkAlarmNetworkName, networkAlarmResource, networkAlarmLayer, networkAlarmNeName, networkAlarmBoardName, networkAlarmName, networkAlarmType, networkAlarmNeNameSource, networkAlarmBoardNameSource, networkAlarmPortNameSource, networkAlarmNeNameDestination, networkAlarmBoardNameDestination, networkAlarmPortNameDestination, networkAlarmAck }
|
|
STATUS current
|
|
DESCRIPTION "Start of an alarm. Contains all the information of the alarm and should be used for logging purposes."
|
|
::= { metropad3 16 }
|
|
|
|
networkAlarmEndNotification NOTIFICATION-TYPE
|
|
OBJECTS { networkAlarmSeverity, networkAlarmKey, networkAlarmGroup, networkAlarmStart, networkAlarmEnd, networkAlarmNetworkName, networkAlarmResource, networkAlarmLayer, networkAlarmNeName, networkAlarmBoardName, networkAlarmName, networkAlarmType, networkAlarmNeNameSource, networkAlarmBoardNameSource, networkAlarmPortNameSource, networkAlarmNeNameDestination, networkAlarmBoardNameDestination, networkAlarmPortNameDestination, networkAlarmAck }
|
|
STATUS current
|
|
DESCRIPTION "End of an alarm. Contains all the information of the alarm and should be used for logging purposes."
|
|
::= { metropad3 17 }
|
|
|
|
networkAlarmAckNotification NOTIFICATION-TYPE
|
|
OBJECTS { networkAlarmSeverity, networkAlarmKey, networkAlarmGroup, networkAlarmStart, networkAlarmEnd, networkAlarmNetworkName, networkAlarmResource, networkAlarmLayer, networkAlarmNeName, networkAlarmBoardName, networkAlarmName, networkAlarmType, networkAlarmAck, networkAlarmAckDate, networkAlarmAckUser }
|
|
STATUS current
|
|
DESCRIPTION "Acknowledgement of an alarm. The alarm may not be terminated."
|
|
::= { metropad3 18 }
|
|
|
|
serverMasterIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to the IP Address of the configured Master Server."
|
|
::= { serverStatus 1 }
|
|
|
|
serverSlaveIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to the IP Address of the configured Slave Server."
|
|
::= { serverStatus 2 }
|
|
|
|
serverIsActive OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to the IP Address of the current server which is as active."
|
|
::= { serverStatus 3 }
|
|
|
|
serverVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It has the version of the Padtec Network Management System."
|
|
::= { serverStatus 4 }
|
|
|
|
serverBuild OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " It has the number of the build at the following notation yyyymmdd. Therefore, this field has a value like yyyymmdd. Where yyyy corresponds to the year, mm to the month (1..12) and dd to the day (1..31)."
|
|
::= { serverStatus 5 }
|
|
|
|
serverUpTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It describes the period of time that happened since the current Active Master is running."
|
|
::= { serverStatus 6 }
|
|
|
|
serverSo OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It describes the operating system on whoch the server is being installed."
|
|
::= { serverStatus 7 }
|
|
|
|
serverFreeDiskSpace OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It has the total of free space at the partition on which the server is running. This partition to be monitored can be configured at the Padtec Network Management System. Padtec strongly advice to set this partittion to that one on which the database keep the data tables stored."
|
|
::= { serverStatus 8 }
|
|
|
|
serverSync OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It identifies if the master and slave servers have the database synchronized."
|
|
::= { serverStatus 9 }
|
|
|
|
networkEventLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NetworkEventLogEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table has the events which are raised by Padtec Network Management System."
|
|
::= { metropad3 19 }
|
|
|
|
networkEventLogEntry OBJECT-TYPE
|
|
SYNTAX NetworkEventLogEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The event which is raised by Padtec Network Management System."
|
|
INDEX { networkEventLogId }
|
|
::= { networkEventLogTable 1 }
|
|
|
|
NetworkEventLogEntry ::= SEQUENCE {
|
|
networkEventLogId Integer32,
|
|
networkEventLogTime DateAndTime,
|
|
networkEventLogResourceType INTEGER,
|
|
networkEventLogResourceName OCTET STRING,
|
|
networkEventLogAction INTEGER,
|
|
networkEventLogRowStatus RowStatus
|
|
}
|
|
|
|
|
|
networkEventLogId OBJECT-TYPE
|
|
SYNTAX Integer32 ( 1 .. 2147483647 )
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "It is unique ID to identifiy a row of this table."
|
|
::= { networkEventLogEntry 1 }
|
|
|
|
|
|
networkEventLogTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the Date and Time when the event happen."
|
|
::= { networkEventLogEntry 2 }
|
|
|
|
networkEventLogResourceType OBJECT-TYPE
|
|
SYNTAX INTEGER {network ( 1 ) , ots ( 2 ) , oms ( 3 ) , circuit ( 4 ), omsotsrelation( 5 ), circuitomsrelation( 6 )}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The type of the resource affected by this event."
|
|
::= { networkEventLogEntry 3 }
|
|
|
|
|
|
networkEventLogResourceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the resource affected by this event."
|
|
::= { networkEventLogEntry 4 }
|
|
|
|
|
|
networkEventLogAction OBJECT-TYPE
|
|
SYNTAX INTEGER { add ( 1 ) , change ( 2 ) , remove ( 3 ) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The executed action."
|
|
::= { networkEventLogEntry 5 }
|
|
|
|
|
|
networkEventLogRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The RowStatus of this entry."
|
|
::= { networkEventLogEntry 6 }
|
|
|
|
networkEventLogNotification NOTIFICATION-TYPE
|
|
OBJECTS { networkEventLogTime, networkEventLogResourceType, networkEventLogResourceName, networkEventLogAction, networkEventLogRowStatus }
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to a notification when an event is raised by Padtec Network Management System."
|
|
::= { metropad3 20 }
|
|
|
|
networkAlarmChangeNotification NOTIFICATION-TYPE
|
|
OBJECTS { networkAlarmSeverity, networkAlarmKey, networkAlarmGroup, networkAlarmStart, networkAlarmNetworkName, networkAlarmResource, networkAlarmLayer, networkAlarmNeName, networkAlarmBoardName, networkAlarmName, networkAlarmType, networkAlarmNeNameSource, networkAlarmBoardNameSource, networkAlarmPortNameSource, networkAlarmNeNameDestination, networkAlarmBoardNameDestination, networkAlarmPortNameDestination, networkAlarmAck }
|
|
STATUS current
|
|
DESCRIPTION "Change of a network alarm. Contains all the information of a network alarm and should be used for logging purposes."
|
|
::= { metropad3 21 }
|
|
|
|
trailAssociationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TrailAssociationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table represents all the contained OTS belonging to the same OMS Trail."
|
|
::= { metropad3 22 }
|
|
|
|
trailAssociationEntry OBJECT-TYPE
|
|
SYNTAX TrailAssociationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The event which is raised by Padtec Network Management System."
|
|
INDEX { omsOtsAssociationTrailIdIndex }
|
|
::= { trailAssociationTable 1 }
|
|
|
|
TrailAssociationEntry ::= SEQUENCE {
|
|
omsOtsAssociationTrailIdIndex Integer32,
|
|
omsOtsAssociationOtsTrailId Integer32,
|
|
omsOtsAssociationOmsTrailId Integer32,
|
|
omsOtsAssociationRowStatus RowStatus
|
|
}
|
|
|
|
omsOtsAssociationTrailIdIndex OBJECT-TYPE
|
|
SYNTAX Integer32 ( 1 .. 2147483647 )
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "It is unique ID to identifiy a row of this table."
|
|
::= { trailAssociationEntry 1 }
|
|
|
|
omsOtsAssociationOtsTrailId OBJECT-TYPE
|
|
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is unique ID to identifiy a row of the OTS Trail table. The id's negatives represents back path."
|
|
::= { trailAssociationEntry 2 }
|
|
|
|
omsOtsAssociationOmsTrailId OBJECT-TYPE
|
|
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is unique ID to identifiy a row of the OMS Trail table. The id's negatives represents back path."
|
|
::= { trailAssociationEntry 3 }
|
|
|
|
omsOtsAssociationRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The RowStatus of this entry."
|
|
::= { trailAssociationEntry 4 }
|
|
|
|
circuitAssociationOmsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TrailAssociationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table represents all the contained OTS belonging to the same OMS Trail."
|
|
::= { metropad3 23 }
|
|
|
|
circuitAssociationOmsEntry OBJECT-TYPE
|
|
SYNTAX CircuitAssociationOmsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The event which is raised by Padtec Network Management System."
|
|
INDEX { circuitOmsAssociationTrailIdIndex }
|
|
::= { circuitAssociationOmsTable 1 }
|
|
|
|
CircuitAssociationOmsEntry ::= SEQUENCE {
|
|
circuitOmsAssociationTrailIdIndex Integer32,
|
|
circuitOmsAssociationCircuitTrailId Integer32,
|
|
circuitOmsAssociationOmsTrailId Integer32,
|
|
circuitOmsAssociationRowStatus RowStatus
|
|
}
|
|
|
|
circuitOmsAssociationTrailIdIndex OBJECT-TYPE
|
|
SYNTAX Integer32 ( 1 .. 2147483647 )
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "It is unique ID to identifiy a row of this table. The id's negatives represents back path."
|
|
::= { circuitAssociationOmsEntry 1 }
|
|
|
|
circuitOmsAssociationCircuitTrailId OBJECT-TYPE
|
|
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is unique ID to identifiy a row of the Circuit Trail table. The id's negatives represents back path."
|
|
::= { circuitAssociationOmsEntry 2 }
|
|
|
|
circuitOmsAssociationOmsTrailId OBJECT-TYPE
|
|
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is unique ID to identifiy a row of the OMS Trail table. "
|
|
::= { circuitAssociationOmsEntry 3 }
|
|
|
|
circuitOmsAssociationRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The RowStatus of this entry."
|
|
::= { circuitAssociationOmsEntry 4 }
|
|
|
|
boardPerformanceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BoardPerformanceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Contains all the measurements which are stored by Padtec Network Management System. "
|
|
::= { metropad3 26 }
|
|
|
|
boardPerformanceEntry OBJECT-TYPE
|
|
SYNTAX BoardPerformanceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A performance measure stored by Padtec Network Management System."
|
|
INDEX { boardPerformanceBoardPart, boardPerformanceBoardSerial, boardPerformanceType, boardPerformancePortNumber, boardPerformancePortType }
|
|
::= { boardPerformanceTable 1 }
|
|
|
|
BoardPerformanceEntry ::= SEQUENCE {
|
|
boardPerformanceBoardPart Integer32,
|
|
boardPerformanceBoardSerial Integer32,
|
|
boardPerformanceType INTEGER,
|
|
boardPerformancePortNumber Integer32,
|
|
boardPerformancePortType INTEGER,
|
|
boardPerformanceValue Integer32,
|
|
boardPerformanceRate OCTET STRING,
|
|
boardPerformanceTime DateAndTime,
|
|
boardPerformanceNeName OCTET STRING,
|
|
boardPerformanceNeMap OCTET STRING,
|
|
boardPerformanceRowStatus RowStatus
|
|
}
|
|
|
|
boardPerformanceBoardPart OBJECT-TYPE
|
|
SYNTAX Integer32 ( 1 .. 2147483647 )
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "It is a number corresponding to the part number at the boardTable. Every performance measurement is associated with a board identified at boardTable."
|
|
::= { boardPerformanceEntry 1 }
|
|
|
|
|
|
boardPerformanceBoardSerial OBJECT-TYPE
|
|
SYNTAX Integer32 ( 1 .. 2147483647 )
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "It is a number corresponding to the serial number at the boardTable. Every performance measurement is associated with a board identified at boardTable."
|
|
::= { boardPerformanceEntry 2 }
|
|
|
|
|
|
boardPerformanceType OBJECT-TYPE
|
|
SYNTAX INTEGER ( 1 .. 2147483647 )
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to the type of the performance measurement has been taken. See the list of types at the manual."
|
|
::= { boardPerformanceEntry 3 }
|
|
|
|
boardPerformancePortNumber OBJECT-TYPE
|
|
SYNTAX Integer32 ( 1 .. 2147483647 )
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "It corresponds the port number of the Padtec Board on which the performance measurenebt has been taken."
|
|
::= { boardPerformanceEntry 4 }
|
|
|
|
boardPerformancePortType OBJECT-TYPE
|
|
SYNTAX INTEGER { client ( 1 ) , wdm ( 2 ) }
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to the type of port of the Padtec Board on which the performance measurement has been taken."
|
|
::= { boardPerformanceEntry 5 }
|
|
|
|
boardPerformanceValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to the performance measurements multipled by 100, in such way that is possible to represent measurements with 2 number precisions. For instance, if the value is 12.25 dBm, then the corresponding value at this table will be 1225."
|
|
::= { boardPerformanceEntry 6 }
|
|
|
|
|
|
boardPerformanceRate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It describes the performance measurements which are displayed at scientific notation. Therefore, all the error rates, transmission rates are mapped at this column."
|
|
::= { boardPerformanceEntry 7 }
|
|
|
|
|
|
boardPerformanceTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It corresponds to the Date and Time when the performance measurement was stored by the Padtec Network Management System."
|
|
::= { boardPerformanceEntry 8 }
|
|
|
|
|
|
boardPerformanceNeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It is the name of NE which the correspondent board entry is placed."
|
|
::= { boardPerformanceEntry 9 }
|
|
|
|
|
|
boardPerformanceNeMap OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "It describes the map which contains the current NE Name."
|
|
::= { boardPerformanceEntry 10 }
|
|
|
|
|
|
boardPerformanceRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The RowStatus of this entry."
|
|
::= { boardPerformanceEntry 11 }
|
|
|
|
lightpadNotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS
|
|
{
|
|
networkAlarmChangeNotification,
|
|
networkEventLogNotification,
|
|
networkAlarmAckNotification,
|
|
networkAlarmEndNotification,
|
|
networkAlarmStartNotification,
|
|
isStatusNotification,
|
|
isRecreateAlarmsNotification,
|
|
isAliveNotification,
|
|
eventNotification,
|
|
alarmEndNotification,
|
|
alarmStartNotification,
|
|
alarmAckNotification
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of notifications used to indicate lightpad MIB
|
|
data consistency and general status information."
|
|
::= { lightpadMIBGroups 1 }
|
|
|
|
lightpadGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
uptimeAgente,
|
|
statusAgente,
|
|
neRowStatus,
|
|
neMap,
|
|
neNetwork,
|
|
neName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing basic instrumentation and
|
|
control of an SNMPv2 entity."
|
|
::= { lightpadMIBGroups 2 }
|
|
|
|
boardPerformanceGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
boardPerformanceRowStatus,
|
|
boardPerformanceNeMap,
|
|
boardPerformanceNeName,
|
|
boardPerformanceTime,
|
|
boardPerformanceRate,
|
|
boardPerformanceValue
|
|
}
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing basic instrumentation and
|
|
control of an SNMPv2 entity."
|
|
::= { lightpadMIBGroups 3 }
|
|
|
|
circuitOmsAssociationGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
circuitOmsAssociationRowStatus,
|
|
circuitOmsAssociationOmsTrailId,
|
|
circuitOmsAssociationCircuitTrailId
|
|
}
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing basic instrumentation and
|
|
control of an SNMPv2 entity."
|
|
::= { lightpadMIBGroups 4 }
|
|
|
|
omsOtsAssociationGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
omsOtsAssociationRowStatus,
|
|
omsOtsAssociationOmsTrailId,
|
|
omsOtsAssociationOtsTrailId
|
|
}
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing basic instrumentation and
|
|
control of an SNMPv2 entity."
|
|
::= { lightpadMIBGroups 5 }
|
|
|
|
networkEventLogGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
networkEventLogRowStatus,
|
|
networkEventLogAction,
|
|
networkEventLogResourceName,
|
|
networkEventLogResourceType,
|
|
networkEventLogTime
|
|
}
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing basic instrumentation and
|
|
control of an SNMPv2 entity."
|
|
::= { lightpadMIBGroups 6 }
|
|
|
|
serverGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
serverSync,
|
|
serverFreeDiskSpace,
|
|
serverSo,
|
|
serverUpTime,
|
|
serverBuild,
|
|
serverVersion,
|
|
serverIsActive,
|
|
serverSlaveIp,
|
|
serverMasterIp
|
|
}
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing basic instrumentation and
|
|
control of an SNMPv2 entity."
|
|
::= { lightpadMIBGroups 7 }
|
|
|
|
circuitTrailGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
circuitTrailRowStatus,
|
|
circuitTrailDatabaseId,
|
|
circuitTrailDestinationPort,
|
|
circuitTrailDestinationBoard,
|
|
circuitTrailDestinationNE,
|
|
circuitTrailDestinationNetwork,
|
|
circuitTrailSourcePort,
|
|
circuitTrailSourceBoard,
|
|
circuitTrailSourceNE,
|
|
circuitTrailSourceNetwork,
|
|
circuitTrailService,
|
|
circuitTrailClientId,
|
|
circuitTrailClientName,
|
|
circuitTrailDescription,
|
|
circuitTrailName
|
|
}
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing basic instrumentation and
|
|
control of an SNMPv2 entity."
|
|
::= { lightpadMIBGroups 8 }
|
|
|
|
omsTrailGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
omsTrailRowStatus,
|
|
omsTrailDatabaseId,
|
|
omsTrailDestinationPort,
|
|
omsTrailDestinationBoard,
|
|
omsTrailDestinationNE,
|
|
omsTrailSourcePort,
|
|
omsTrailSourceBoard,
|
|
omsTrailSourceNE,
|
|
omsTrailDescription,
|
|
omsTrailName
|
|
}
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing basic instrumentation and
|
|
control of an SNMPv2 entity."
|
|
::= { lightpadMIBGroups 9 }
|
|
|
|
otsTrailGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
otsTrailRowStatus,
|
|
otsTrailDatabaseId,
|
|
otsTrailDestinationPort,
|
|
otsTrailDestinationBoard,
|
|
otsTrailDestinationNE,
|
|
otsTrailSourcePort,
|
|
otsTrailSourceBoard,
|
|
otsTrailSourceNE,
|
|
otsTrailDistance,
|
|
otsTrailFiberType,
|
|
otsTrailDescription,
|
|
otsTrailName
|
|
}
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing basic instrumentation and
|
|
control of an SNMPv2 entity."
|
|
::= { lightpadMIBGroups 10 }
|
|
|
|
networkAlarmObjectGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
networkAlarmRowStatus,
|
|
networkAlarmAckUser,
|
|
networkAlarmAckDate,
|
|
networkAlarmAck,
|
|
networkAlarmPortNameDestination,
|
|
networkAlarmBoardNameDestination,
|
|
networkAlarmNeNameDestination,
|
|
networkAlarmPortNameSource,
|
|
networkAlarmBoardNameSource,
|
|
networkAlarmNeNameSource,
|
|
networkAlarmType,
|
|
networkAlarmName,
|
|
networkAlarmBoardName,
|
|
networkAlarmNeName,
|
|
networkAlarmLayer,
|
|
networkAlarmResource,
|
|
networkAlarmNetworkName,
|
|
networkAlarmEnd,
|
|
networkAlarmStart,
|
|
networkAlarmGroup,
|
|
networkAlarmKey,
|
|
networkAlarmSeverity
|
|
}
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing basic instrumentation and
|
|
control of an SNMPv2 entity."
|
|
::= { lightpadMIBGroups 11 }
|
|
|
|
alarmsNotificationGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
alarmsNotificationNeName,
|
|
alarmsNotificationBoardName,
|
|
alarmsNotificationBoardSerial,
|
|
alarmsNotificationBoardPart
|
|
}
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing basic instrumentation and
|
|
control of an SNMPv2 entity."
|
|
::= { lightpadMIBGroups 12 }
|
|
|
|
performanceGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
performanceRowStatus,
|
|
performanceOid,
|
|
performanceNeMap,
|
|
performanceNeName,
|
|
performanceTime,
|
|
performanceRate,
|
|
performanceValue,
|
|
performancePortNumber,
|
|
performancePortType,
|
|
performanceType,
|
|
performanceBoardSerial,
|
|
performanceBoardPart
|
|
}
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing basic instrumentation and
|
|
control of an SNMPv2 entity."
|
|
::= { lightpadMIBGroups 13 }
|
|
|
|
eventGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
eventRowStatus,
|
|
eventNeMap,
|
|
eventNeName,
|
|
eventTime,
|
|
eventBoardSlot,
|
|
eventBoardSubRack,
|
|
eventBoardRackPosition,
|
|
eventBoardSerial,
|
|
eventBoardPart,
|
|
eventName,
|
|
eventType
|
|
}
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing basic instrumentation and
|
|
control of an SNMPv2 entity."
|
|
::= { lightpadMIBGroups 14 }
|
|
|
|
alarmGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
alarmRowStatus,
|
|
alarmNeMap,
|
|
alarmNeName,
|
|
alarmAckUser,
|
|
alarmAckDescription,
|
|
alarmAckDate,
|
|
alarmEnd,
|
|
alarmStart,
|
|
alarmBoardSlot,
|
|
alarmBoardSubRack,
|
|
alarmResource,
|
|
alarmBoardRackPosition,
|
|
alarmBoardSerial,
|
|
alarmBoardPart,
|
|
alarmName,
|
|
alarmSeverity,
|
|
alarmType,
|
|
alarmId
|
|
}
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing basic instrumentation and
|
|
control of an SNMPv2 entity."
|
|
::= { lightpadMIBGroups 15 }
|
|
|
|
boardGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
boardRowStatus,
|
|
boardState,
|
|
boardNeMap,
|
|
boardNeName,
|
|
boardVersion,
|
|
boardSlot,
|
|
boardSubRack,
|
|
boardRackPosition,
|
|
boardDescription,
|
|
boardName,
|
|
boardModel,
|
|
boardSerial,
|
|
boardPart
|
|
}
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing basic instrumentation and
|
|
control of an SNMPv2 entity."
|
|
::= { lightpadMIBGroups 16 }
|
|
|
|
END |