2129 lines
70 KiB
Plaintext

-- File Name : LIGHTPAD-MIB.mib
-- Date : Thu Mar 31 16:01:25 BRST 2009
-- Author : AdventNet Agent Toolkit Java Edition - MIB Editor 6
-- Authors : Marcelo Uesono <uesono@padtec.com.br>, Lavoisier J.L.Farias <lavoisier@padtec.com.br>, Thiago Ribeiro Mendes <thiago.mendes@padtec.com.br>, Daniel Araujo <daniel@padtec.com.br>, Denis Neves <dsantos@padtec.com.br>
-- This MIB was changed at September 10th-2008 in order to add the field boarModel for the following traps: alarmStartNotification, alarmEndNotification, alarmAckNotification, eventNotification
-- This MIB was changed at September 22nd-2008 in order to remove the fields alarmAckDate, alarmAckUser, alarmAckDescription for the following traps: alarmStartNotification and alarmEndNotification
-- This MIB was updated at January 2009 to provide Network Management System alarms and information. The following tables were added: circuitTrailTable, networkAlarmTable, otsTrailTable and omsTrailTable. The following notification were added: networkAlarmStartNotification, networkAlarmEndNotification and networkAlarmAckNotification. When a trail is removed at the Management System, the current alarms of this trail are ended.
-- This MIB was changed at January 22nd-2009 in order to add the fields networkAlarmNeNameSource, networkAlarmBoardNameSource, networkAlarmPortNameSource, networkAlarmNeNameDestination, networkAlarmBoardNameDestination, and networkAlarmPortNameDestination to the networkAlarmTable, networkAlarmStartNotification, and networkAlarmEndNotification.
-- This MIB was changed at March 31st-2009 to support estimated BER Metric
-- This MIB was changed at April 23rd-2009 to include the networkAlarmChangeNotification
-- This MIB was changed at May 12th-2009 to include the field boardState in boardTable and new eventType: boardInOperation ( 4 ) and boardInTest ( 5 )
-- This MIB was changed at Sep 16th-2010 to add new types of performance
-- This MIB was changed at Aug 28th-2014 to add table boardPerformanceTable (but was only used in v3_13_1_20140114_patchs_GERLP881)
-- This MIB was updated at Jun 30th-2015 to add field alarmId for the following traps: alarmStartNotification, alarmEndNotification and alarmAckNotification
-- This MIB was updated at Jul 07th-2015 to add comment about alarmId not is sent when parameter -DsendalarmId as value false.
-- This MIB was updated at Jan 02nd-2017 to add table trailAssociationTable relation OtsId between OmsId.
-- This MIB was updated at Jan 02nd-2017 to add table circuitAssociationOmsTable relation CircuitId between OmsId.
-- This MIB was changed at Aug 03rd-2018 to use table boardPerformanceTable to fix SNIV-69 (Fixed OID for board performance measures)
-- This MIB was changed at Jul 15rd-2020 Refactoring to RFC-2580 compliance.
METROPAD3 DEFINITIONS ::= BEGIN
IMPORTS
RowStatus, DateAndTime, TruthValue
FROM SNMPv2-TC
snmp
FROM RFC1213-MIB
enterprises, MODULE-IDENTITY, OBJECT-TYPE, Integer32, NOTIFICATION-TYPE, TimeTicks, IpAddress
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF;
moduleIdentity MODULE-IDENTITY
LAST-UPDATED "200904231617Z"
ORGANIZATION "Padtec S/A http://www.padtec.com.br"
CONTACT-INFO "SAC: sac@padtec.com.br"
DESCRIPTION "This Module is responsible to map all the Padtec Manageable Equipment to SNMP."
REVISION "200904231617Z"
DESCRIPTION "This Revision contais the NMS capabilities."
::= { enterprises 1 }
org OBJECT IDENTIFIER
::= { iso 3 }
dod OBJECT IDENTIFIER
::= { org 6 }
internet OBJECT IDENTIFIER
::= { dod 1 }
private OBJECT IDENTIFIER
::= { internet 4 }
enterprises OBJECT IDENTIFIER
::= { private 1 }
padtec OBJECT IDENTIFIER
::= { enterprises 14846 }
metropad3 OBJECT IDENTIFIER
::= { padtec 3 }
lightpadMIBGroups OBJECT IDENTIFIER ::= { moduleIdentity 1 }
neTable OBJECT-TYPE
SYNTAX SEQUENCE OF NeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Contains all the Network Elements which were associated at the Management System. A network element at Padtec platform is a supervisor unit that manages a bundle of boards and has a network transport function at the network."
::= { metropad3 1 }
neEntry OBJECT-TYPE
SYNTAX NeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The Network Element."
INDEX { neId }
::= { neTable 1 }
NeEntry ::= SEQUENCE {
neId Integer32,
neName OCTET STRING,
neNetwork OCTET STRING,
neMap OCTET STRING,
neRowStatus RowStatus
}
neId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 2147483647 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "It is a unique ID to identifiy a row of this table."
::= { neEntry 1 }
neName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is an unique identifier that describes the Name of Network Element. At Padtec system, this name is unique and duplication are not allowed."
::= { neEntry 2 }
neNetwork OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It describes the network or system which contains the current NE Name."
::= { neEntry 3 }
neMap OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It describes the map which contains the current NE Name."
::= { neEntry 4 }
neRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The RowStatus of this entry."
::= { neEntry 5 }
boardTable OBJECT-TYPE
SYNTAX SEQUENCE OF BoardEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Contains all boards managed by Padtec Network Management System."
::= { metropad3 2 }
boardEntry OBJECT-TYPE
SYNTAX BoardEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The managed board."
INDEX { boardId }
::= { boardTable 1 }
BoardEntry ::= SEQUENCE {
boardId Integer32,
boardPart Integer32,
boardSerial Integer32,
boardModel OCTET STRING,
boardName OCTET STRING,
boardDescription OCTET STRING,
boardSubRack Integer32,
boardSlot Integer32,
boardVersion OCTET STRING,
boardNeName OCTET STRING,
boardNeMap OCTET STRING,
boardState INTEGER,
boardRowStatus RowStatus,
boardRackPosition Integer32
}
boardId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 2147483647 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "It is a unique ID to identifiy a row of this table."
::= { boardEntry 1 }
boardPart OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the part number which defines the model of Padtec board which is being managed."
::= { boardEntry 2 }
boardSerial OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the serial number which defines the serial number of determined model of Padtec board which is being managed."
::= { boardEntry 3 }
boardModel OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the model name of the Padtec board which is being managed."
::= { boardEntry 4 }
boardName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the name defined by the user of Padtec Network Management System."
::= { boardEntry 5 }
boardDescription OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It corresponds to the description fullfilled by the user of Padtec Network Management System."
::= { boardEntry 6 }
boardRackPosition OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the number of rack position on which the board of correspondent entry is placed."
::= { boardEntry 14 }
boardSubRack OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the number of sub-rack on which the board of correspondent entry is placed."
::= { boardEntry 7 }
boardSlot OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the number of slot on which the board of correspondent entry is placed."
::= { boardEntry 8 }
boardVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the board Version"
::= { boardEntry 9 }
boardNeName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the name of NE which the correspondent board entry is placed."
::= { boardEntry 10 }
boardNeMap OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It describes the map which contains the current NE Name."
::= { boardEntry 11 }
boardState OBJECT-TYPE
SYNTAX INTEGER { operation ( 1 ) , test ( 2 ) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It identifies the state of the board."
::= { boardEntry 12 }
boardRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The RowStatus of this entry."
::= { boardEntry 13 }
alarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Contains all the alarms which are raised by Padtec Network Management System. This table does NOT have events."
::= { metropad3 3 }
alarmEntry OBJECT-TYPE
SYNTAX AlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The alarm at Padtec Network Management System."
INDEX { alarmId }
::= { alarmTable 1 }
AlarmEntry ::= SEQUENCE {
alarmId Integer32,
alarmType Integer32,
alarmSeverity INTEGER,
alarmName OCTET STRING,
alarmBoardPart Integer32,
alarmBoardSerial Integer32,
alarmBoardSubRack Integer32,
alarmBoardSlot Integer32,
alarmStart DateAndTime,
alarmEnd DateAndTime,
alarmAckDate DateAndTime,
alarmAckDescription OCTET STRING,
alarmAckUser OCTET STRING,
alarmNeName OCTET STRING,
alarmNeMap OCTET STRING,
alarmRowStatus RowStatus,
alarmBoardRackPosition Integer32,
alarmResource OCTET STRING
}
alarmId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 2147483647 )
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "It is a unique ID to identifiy a row of this table."
::= { alarmEntry 1 }
alarmType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is an integer which describes in a unique manner the alarm at Padtec Network Management System. Different types of boards have different numbers of alarmTypes. For instance, the LOS Alarm has an identifier for the Board amplifier, and has a different one for the OTN trasponder board."
::= { alarmEntry 2 }
alarmSeverity OBJECT-TYPE
SYNTAX INTEGER { clear ( 1 ) , warning ( 2 ) , minor ( 3 ) , major ( 4 ) , critical ( 5 ) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It identifies the severity of each alarm."
::= { alarmEntry 3 }
alarmName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is a text that describes the name of the corresponding alarm. It has the same text as viewed by the user of Padtec Network Management System."
::= { alarmEntry 4 }
alarmBoardPart OBJECT-TYPE
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is a number corresponding to the part number at the boardTable. Every alarm has to have a associated board identified at boardTable."
::= { alarmEntry 5 }
alarmBoardSerial OBJECT-TYPE
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is a number corresponding to the serial number at the boardTable. Every alarm has to have a associated board identified at boardTable."
::= { alarmEntry 6 }
alarmBoardRackPosition OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the number of rack position on which the board of correspondent entry is placed."
::= { alarmEntry 17 }
alarmResource OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is a text that describes the name of the corresponding alarm. It has the same text as viewed by the user of Padtec Network Management System."
::= { alarmEntry 18 }
alarmBoardSubRack OBJECT-TYPE
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the number of sub-rack on which the board of correspondent entry is placed."
::= { alarmEntry 7 }
alarmBoardSlot OBJECT-TYPE
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the number of slot on which the board of correspondent entry is placed."
::= { alarmEntry 8 }
alarmStart OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the Date and Time when the alarm started, .i.e.,the date and time when the alarm was raised."
::= { alarmEntry 9 }
alarmEnd OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the Date and Time when the alarm ended, .i.e.,the date and time when the alarm was ended. All active alarms have this field as an empty value."
::= { alarmEntry 10 }
alarmAckDate OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the Date and Time when the alarm was acknowledged."
::= { alarmEntry 11 }
alarmAckDescription OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the description corresponding to the text inputed by the user of Padtec Network Management System, or by anotehr NMS that acknowledge the corresponding alarm."
::= { alarmEntry 12 }
alarmAckUser OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the name of the user that acknowledged the alarm of Padtec Network Management System. If the alarm was acknowledged by another NMS, so this field will have the value equals to the word NMS."
::= { alarmEntry 13 }
alarmNeName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the name of Network Element at neTable on which the event has been identified."
::= { alarmEntry 14 }
alarmNeMap OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It describes the map which contains the current NE Name."
::= { alarmEntry 15 }
alarmRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The RowStatus of this entry."
::= { alarmEntry 16 }
eventTable OBJECT-TYPE
SYNTAX SEQUENCE OF EventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Contains all the events which are raised by Padtec Network Management System. This table does NOT have alarms. So, all the commands sent to the boards are registered at this table."
::= { metropad3 4 }
eventEntry OBJECT-TYPE
SYNTAX EventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The event which is raised by Padtec Network Management System."
INDEX { eventId }
::= { eventTable 1 }
EventEntry ::= SEQUENCE {
eventId Integer32,
eventType INTEGER,
eventName OCTET STRING,
eventBoardPart Integer32,
eventBoardSerial Integer32,
eventBoardSubRack Integer32,
eventBoardSlot Integer32,
eventTime DateAndTime,
eventNeName OCTET STRING,
eventNeMap OCTET STRING,
eventRowStatus RowStatus,
eventBoardRackPosition Integer32
}
eventId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 2147483647 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "It is a unique ID to identifiy a row of this table."
::= { eventEntry 1 }
eventType OBJECT-TYPE
SYNTAX INTEGER { newNe ( 0 ) , removeNe ( 1 ) , newBoard ( 2 ) , removeBoard ( 3 ) , boardInOperation ( 4 ) , boardInTest ( 5 ), updateNE (6) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is an integer which describes in a unique manner the event at Padtec Network Management System."
::= { eventEntry 2 }
eventName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is a text that describes the name of the corresponding event. It has the same text as viewed by the user of Padtec Network Management System."
::= { eventEntry 3 }
eventBoardPart OBJECT-TYPE
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is a number corresponding to the part number at the boardTable. Every event has to have a associated board identified at boardTable."
::= { eventEntry 4 }
eventBoardSerial OBJECT-TYPE
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is a number corresponding to the serial number at the boardTable. Every event has to have a associated board identified at boardTable."
::= { eventEntry 5 }
eventBoardRackPosition OBJECT-TYPE
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the number of rack position on which the board of correspondent entry is placed."
::= { eventEntry 12 }
eventBoardSubRack OBJECT-TYPE
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the number of sub-rack on which the board of correspondent entry is placed."
::= { eventEntry 6 }
eventBoardSlot OBJECT-TYPE
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the number of slot on which the board of correspondent entry is placed."
::= { eventEntry 7 }
eventTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the Date and Time when the event happen."
::= { eventEntry 8 }
eventNeName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the name of Network Element at NE Table on which the event has been identified."
::= { eventEntry 9 }
eventNeMap OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It describes the map which contains the current NE Name."
::= { eventEntry 10 }
eventRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The RowStatus of this entry."
::= { eventEntry 11 }
performanceTable OBJECT-TYPE
SYNTAX SEQUENCE OF PerformanceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Contains all the measurements which are stored by Padtec Network Management System. "
::= { metropad3 5 }
performanceEntry OBJECT-TYPE
SYNTAX PerformanceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A performance measure stored by Padtec Network Management System."
INDEX { performanceId }
::= { performanceTable 1 }
PerformanceEntry ::= SEQUENCE {
performanceId Integer32,
performanceBoardPart Integer32,
performanceBoardSerial Integer32,
performanceType INTEGER,
performancePortType INTEGER,
performancePortNumber Integer32,
performanceValue Integer32,
performanceRate OCTET STRING,
performanceTime DateAndTime,
performanceNeName OCTET STRING,
performanceNeMap OCTET STRING,
performanceRowStatus RowStatus,
performanceOid Integer32
}
performanceId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 2147483647 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "It is a unique ID to identifiy a row of this table."
::= { performanceEntry 1 }
performanceBoardPart OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is a number corresponding to the part number at the boardTable. Every performance measurement is associated with a board identified at boardTable."
::= { performanceEntry 2 }
performanceBoardSerial OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is a number corresponding to the serial number at the boardTable. Every performance measurement is associated with a board identified at boardTable."
::= { performanceEntry 3 }
performanceType OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It corresponds to the type of the performance measurement has been taken. See the list of types at the manual."
::= { performanceEntry 5 }
performancePortType OBJECT-TYPE
SYNTAX INTEGER { client ( 1 ) , wdm ( 2 ) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It corresponds to the type of port of the Padtec Board on which the performance measurement has been taken."
::= { performanceEntry 6 }
performancePortNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It corresponds the port number of the Padtec Board on which the performance measurenebt has been taken."
::= { performanceEntry 7 }
performanceValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It corresponds to the performance measurements multipled by 100, in such way that is possible to represent measurements with 2 number precisions. For instance, if the value is 12.25 dBm, then the corresponding value at this table will be 1225."
::= { performanceEntry 8 }
performanceRate OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It describes the performance measurements which are displayed at scientific notation. Therefore, all the error rates, transmission rates are mapped at this column."
::= { performanceEntry 9 }
performanceTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It corresponds to the Date and Time when the performance measurement was stored by the Padtec Network Management System."
::= { performanceEntry 10 }
performanceNeName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the name of NE which the correspondent board entry is placed."
::= { performanceEntry 11 }
performanceNeMap OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It describes the map which contains the current NE Name."
::= { performanceEntry 12 }
performanceOid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is a number corresponding to the part number at the boardTable. Every performance measurement is associated with a board identified at boardTable."
::= { performanceEntry 14 }
performanceRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The RowStatus of this entry."
::= { performanceEntry 13 }
serverStatus OBJECT IDENTIFIER
::= { metropad3 6 }
alarmStartNotification NOTIFICATION-TYPE
OBJECTS { alarmName, alarmBoardPart, alarmBoardSerial, alarmBoardRackPosition, alarmBoardSlot, alarmBoardSubRack, alarmNeName, alarmNeMap, alarmType, alarmSeverity, alarmStart, alarmRowStatus, boardModel, alarmId }
STATUS current
DESCRIPTION "It corresponds to a notification when an alarm is raised. alarmId not is sent when parameter -DsendalarmId as value false."
::= { metropad3 7 }
alarmEndNotification NOTIFICATION-TYPE
OBJECTS { alarmName, alarmBoardPart, alarmBoardSerial, alarmBoardRackPosition, alarmBoardSlot, alarmBoardSubRack, alarmNeName, alarmNeMap, alarmType, alarmSeverity, alarmEnd, alarmRowStatus, boardModel, alarmId }
STATUS current
DESCRIPTION "It corresponds to a notification when an alarm is terminated. obs alarmId not is sent when parameter -DsendalarmId as value false."
::= { metropad3 8 }
alarmAckNotification NOTIFICATION-TYPE
OBJECTS { alarmName, alarmBoardPart, alarmBoardSerial, alarmBoardRackPosition, alarmBoardSlot, alarmBoardSubRack, alarmNeName, alarmNeMap, alarmType, alarmSeverity, alarmStart, alarmEnd, alarmAckDate, alarmAckUser, alarmAckDescription, alarmRowStatus, boardModel, alarmId }
STATUS current
DESCRIPTION "It corresponds to a notification when an alarm is acknowledge. obs alarmId not is sent when parameter -DsendalarmId as value false."
::= { metropad3 9 }
eventNotification NOTIFICATION-TYPE
OBJECTS { eventName, eventBoardPart, eventBoardSerial, eventBoardRackPosition, eventBoardSlot, eventBoardSubRack, eventNeName, eventNeMap, eventType, eventTime, eventRowStatus, boardModel }
STATUS current
DESCRIPTION "It corresponds to a notification when an event happen."
::= { metropad3 10 }
isAliveNotification NOTIFICATION-TYPE
STATUS current
DESCRIPTION "It corresponds to a notification to show system is still alive."
::= { metropad3 11 }
isRecreateAlarmsNotification NOTIFICATION-TYPE
OBJECTS { alarmsNotificationBoardPart, alarmsNotificationBoardSerial, alarmsNotificationBoardName, alarmsNotificationNeName }
STATUS current
DESCRIPTION "It corresponds to a notification to recreate Alarmes"
::= { metropad3 24 }
isStatusNotification NOTIFICATION-TYPE
OBJECTS { statusAgente, uptimeAgente }
STATUS current
DESCRIPTION "It corresponds to a notification to show system is still alive."
::= { metropad3 25 }
statusAgente OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is a text that describes the name of the corresponding event. It has the same text as viewed by the user of Padtec Network Management System."
::= { isStatusNotification 1 }
uptimeAgente OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is a text that describes the name of the corresponding event. It has the same text as viewed by the user of Padtec Network Management System."
::= { isStatusNotification 2 }
alarmsNotificationBoardPart OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is a text that describes the name of the corresponding event. It has the same text as viewed by the user of Padtec Network Management System."
::= { isRecreateAlarmsNotification 1 }
alarmsNotificationBoardSerial OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is a text that describes the name of the corresponding event. It has the same text as viewed by the user of Padtec Network Management System."
::= { isRecreateAlarmsNotification 2 }
alarmsNotificationBoardName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is a text that describes the name of the corresponding event. It has the same text as viewed by the user of Padtec Network Management System."
::= { isRecreateAlarmsNotification 3 }
alarmsNotificationNeName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is a text that describes the name of the corresponding event. It has the same text as viewed by the user of Padtec Network Management System."
::= { isRecreateAlarmsNotification 4 }
networkAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF NetworkAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Contains the Padtec Network Management System alarms. This table does NOT have system events (see eventTable) neither EMS alarms (see alarmTable)."
::= { metropad3 12 }
networkAlarmEntry OBJECT-TYPE
SYNTAX NetworkAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The Padtec Network Management System alarms."
INDEX { networkAlarmId }
::= { networkAlarmTable 1 }
NetworkAlarmEntry ::= SEQUENCE {
networkAlarmId Integer32,
networkAlarmSeverity INTEGER,
networkAlarmKey Integer32,
networkAlarmGroup INTEGER,
networkAlarmStart DateAndTime,
networkAlarmEnd DateAndTime,
networkAlarmNetworkName OCTET STRING,
networkAlarmResource OCTET STRING,
networkAlarmLayer INTEGER,
networkAlarmNeName OCTET STRING,
networkAlarmBoardName OCTET STRING,
networkAlarmName OCTET STRING,
networkAlarmType INTEGER,
networkAlarmNeNameSource OCTET STRING,
networkAlarmBoardNameSource OCTET STRING,
networkAlarmPortNameSource OCTET STRING,
networkAlarmNeNameDestination OCTET STRING,
networkAlarmBoardNameDestination OCTET STRING,
networkAlarmPortNameDestination OCTET STRING,
networkAlarmAck TruthValue,
networkAlarmAckDate DateAndTime,
networkAlarmAckUser OCTET STRING,
networkAlarmRowStatus RowStatus
}
networkAlarmId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 2147483647 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "It is a unique ID to identifiy a row of this table."
::= { networkAlarmEntry 1 }
networkAlarmSeverity OBJECT-TYPE
SYNTAX INTEGER { indeterminated ( 0 ) , clear ( 1 ) , warning ( 2 ) , minor ( 3 ) , major ( 4 ) , critical ( 5 ) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It identifies the severity of each alarm."
::= { networkAlarmEntry 2 }
networkAlarmKey OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is an integer which describes in a unique manner the alarm at Padtec Network Management System."
::= { networkAlarmEntry 3 }
networkAlarmGroup OBJECT-TYPE
SYNTAX INTEGER { communicationsAlarm ( 2 ) , environmentalAlarm ( 3 ) , equipmentAlarm ( 4 ) , processingErrorAlarm ( 10 ) , qualityOfServiceAlarm ( 11 ) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The category of this alarm as defined by CCITT Recommendation X.733."
::= { networkAlarmEntry 4 }
networkAlarmStart OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the Date and Time when the alarm started, .i.e.,the date and time when the event happened."
::= { networkAlarmEntry 5 }
networkAlarmEnd OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the Date and Time when the alarm ended. All active (not cleared ones) alarms show the value 1969-12-31,22:0:0.0,-3:0."
::= { networkAlarmEntry 6 }
networkAlarmNetworkName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of the network affected by the alarm."
::= { networkAlarmEntry 7 }
networkAlarmResource OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of the affected trail or circuit."
::= { networkAlarmEntry 8 }
networkAlarmLayer OBJECT-TYPE
SYNTAX INTEGER { ots ( 1 ) , oms ( 2 ) , circuit ( 3 ) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Layer of the alarm: tranport (1), multiplex (2) or end-to-end (3)."
::= { networkAlarmEntry 9 }
networkAlarmNeName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the name of Network Element at NE Table on which the event has been identified."
::= { networkAlarmEntry 10 }
networkAlarmBoardName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of the affected board."
::= { networkAlarmEntry 11 }
networkAlarmName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is a text that describes the name of the corresponding alarm. It has the same text as viewed by the user of Padtec Network Management System."
::= { networkAlarmEntry 12 }
networkAlarmType OBJECT-TYPE
SYNTAX INTEGER { ots ( 1 ) , otsClient ( 2 ) , och ( 3 ) , circuit ( 4 ) , oam ( 5 ) , otn25G ( 6 ) , otu1 ( 7 ) , odu1 ( 8 ) , sdh ( 9 ) , otn10G ( 10 ) , otu2 ( 11 ) , odu2 ( 12 ) , opu2 ( 13 ) , equipment ( 14 ) , management ( 15 ) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Shows the kind of this network alarm."
::= { networkAlarmEntry 13 }
networkAlarmNeNameSource OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of the source NE of the affected trail or circuit."
::= { networkAlarmEntry 14 }
networkAlarmBoardNameSource OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of the source board of the affected trail or circuit."
::= { networkAlarmEntry 15 }
networkAlarmPortNameSource OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of the source port/interface of the affected trail or circuit."
::= { networkAlarmEntry 16 }
networkAlarmNeNameDestination OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of the destination NE of the affected trail or circuit."
::= { networkAlarmEntry 17 }
networkAlarmBoardNameDestination OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of the destination board of the affected trail or circuit."
::= { networkAlarmEntry 18 }
networkAlarmPortNameDestination OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of the destination port/interface of the affected trail or circuit."
::= { networkAlarmEntry 19 }
networkAlarmAck OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Identifies if the alarm was acknowledged. This object has the value 'true(1)', if this alarm was acknowledged and the value 'false(2)' otherwise."
::= { networkAlarmEntry 20 }
networkAlarmAckDate OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the Date and Time when the alarm was acknowledged or 1969-12-31,22:0:0.0,-3:0 for alarms not acknowledged."
::= { networkAlarmEntry 21 }
networkAlarmAckUser OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the name of the user that acknowledged the alarm of Padtec Network Management System. If the alarm was acknowledged by another NMS, so this field will have the value equals to the word NMS. This field will have the value equals to the word N/A if the corresponding alarm was not acknowledged."
::= { networkAlarmEntry 22 }
networkAlarmRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The RowStatus of this entry."
::= { networkAlarmEntry 23 }
otsTrailTable OBJECT-TYPE
SYNTAX SEQUENCE OF OtsTrailEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Contains all OTS trails."
::= { metropad3 13 }
otsTrailEntry OBJECT-TYPE
SYNTAX OtsTrailEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The OTS Trail."
INDEX { otsTrailId }
::= { otsTrailTable 1 }
OtsTrailEntry ::= SEQUENCE {
otsTrailId Integer32,
otsTrailName OCTET STRING,
otsTrailDescription OCTET STRING,
otsTrailFiberType OCTET STRING,
otsTrailDistance Integer32,
otsTrailSourceNE OCTET STRING,
otsTrailSourceBoard OCTET STRING,
otsTrailSourcePort OCTET STRING,
otsTrailDestinationNE OCTET STRING,
otsTrailDestinationBoard OCTET STRING,
otsTrailDestinationPort OCTET STRING,
otsTrailDatabaseId Integer32,
otsTrailRowStatus RowStatus
}
otsTrailId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 2147483647 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "It is a unique ID to identifiy a row of this table."
::= { otsTrailEntry 1 }
otsTrailName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this trail OTS."
::= { otsTrailEntry 2 }
otsTrailDescription OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of this trail OTS."
::= { otsTrailEntry 3 }
otsTrailFiberType OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of optical fiber."
::= { otsTrailEntry 4 }
otsTrailDistance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The distance of this OTS Trail in kilometers multipled by 100, in such way that is possible to represent measurements with 2 number precisions. For instance, if the value is 90.25 km, then the corresponding value at this table will be 9025."
::= { otsTrailEntry 5 }
otsTrailSourceNE OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this OTS trail's source NE. See neTable."
::= { otsTrailEntry 6 }
otsTrailSourceBoard OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this OTS trail's source board. See boardTable."
::= { otsTrailEntry 7 }
otsTrailSourcePort OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this OTS trail's source port/interface."
::= { otsTrailEntry 8 }
otsTrailDestinationNE OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this OTS trail's destination NE. See neTable."
::= { otsTrailEntry 9 }
otsTrailDestinationBoard OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this OTS trail's destination board. See boardTable."
::= { otsTrailEntry 10 }
otsTrailDestinationPort OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this OTS trail's destination port/interface."
::= { otsTrailEntry 11 }
otsTrailDatabaseId OBJECT-TYPE
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is a unique ID to identifiy a row of this table. The id's negatives represents back path."
::= { otsTrailEntry 12 }
otsTrailRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The RowStatus of this entry."
::= { otsTrailEntry 13 }
omsTrailTable OBJECT-TYPE
SYNTAX SEQUENCE OF OmsTrailEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Contains all Optical Multiplex Section (OMS) Trails."
::= { metropad3 14 }
omsTrailEntry OBJECT-TYPE
SYNTAX OmsTrailEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The Optical Multiplex Section (OMS)."
INDEX { omsTrailId }
::= { omsTrailTable 1 }
OmsTrailEntry ::= SEQUENCE {
omsTrailId Integer32,
omsTrailName OCTET STRING,
omsTrailDescription OCTET STRING,
omsTrailSourceNE OCTET STRING,
omsTrailSourceBoard OCTET STRING,
omsTrailSourcePort OCTET STRING,
omsTrailDestinationNE OCTET STRING,
omsTrailDestinationBoard OCTET STRING,
omsTrailDestinationPort OCTET STRING,
omsTrailDatabaseId Integer32,
omsTrailRowStatus RowStatus
}
omsTrailId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 2147483647 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "It is a unique ID to identifiy a row of this table."
::= { omsTrailEntry 1 }
omsTrailName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The identifier of the OMS Trail."
::= { omsTrailEntry 2 }
omsTrailDescription OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the OMS Trail."
::= { omsTrailEntry 3 }
omsTrailSourceNE OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this OMS trail's source NE. See neTable."
::= { omsTrailEntry 4 }
omsTrailSourceBoard OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this OMS trail's source board. See boardTable."
::= { omsTrailEntry 5 }
omsTrailSourcePort OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this OMS trail's source port/interface."
::= { omsTrailEntry 6 }
omsTrailDestinationNE OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this OMS trail's destination NE. See neTable."
::= { omsTrailEntry 7 }
omsTrailDestinationBoard OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this OMS trail's destination board. See boardTable."
::= { omsTrailEntry 8 }
omsTrailDestinationPort OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this OMS trail's destination port/interface."
::= { omsTrailEntry 9 }
omsTrailDatabaseId OBJECT-TYPE
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The identifier of the OMS Trail. The id's negatives represents back path."
::= { omsTrailEntry 10 }
omsTrailRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The RowStatus of this entry."
::= { omsTrailEntry 11 }
circuitTrailTable OBJECT-TYPE
SYNTAX SEQUENCE OF CircuitTrailEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Contains all circuit end-to-end trails."
::= { metropad3 15 }
circuitTrailEntry OBJECT-TYPE
SYNTAX CircuitTrailEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The circuit end-to-end trail."
INDEX { circuitTrailId }
::= { circuitTrailTable 1 }
CircuitTrailEntry ::= SEQUENCE {
circuitTrailId Integer32,
circuitTrailName OCTET STRING,
circuitTrailDescription OCTET STRING,
circuitTrailClientName OCTET STRING,
circuitTrailClientId OCTET STRING,
circuitTrailService OCTET STRING,
circuitTrailSourceNetwork OCTET STRING,
circuitTrailSourceNE OCTET STRING,
circuitTrailSourceBoard OCTET STRING,
circuitTrailSourcePort OCTET STRING,
circuitTrailDestinationNetwork OCTET STRING,
circuitTrailDestinationNE OCTET STRING,
circuitTrailDestinationBoard OCTET STRING,
circuitTrailDestinationPort OCTET STRING,
circuitTrailDatabaseId Integer32,
circuitTrailRowStatus RowStatus
}
circuitTrailId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 2147483647 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "It is a unique ID to identifiy a row of this table."
::= { circuitTrailEntry 1 }
circuitTrailName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Identifier of the end-to-end circuit."
::= { circuitTrailEntry 2 }
circuitTrailDescription OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the end-to-end circuit"
::= { circuitTrailEntry 3 }
circuitTrailClientName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of the client of the circuit."
::= { circuitTrailEntry 4 }
circuitTrailClientId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The identifier of the client of circuit."
::= { circuitTrailEntry 5 }
circuitTrailService OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The service of the end-to-end circuit."
::= { circuitTrailEntry 6 }
circuitTrailSourceNetwork OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of the circuit's source network."
::= { circuitTrailEntry 7 }
circuitTrailSourceNE OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this circuit's source NE. See neTable."
::= { circuitTrailEntry 8 }
circuitTrailSourceBoard OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this circuit's source board. See boardTable."
::= { circuitTrailEntry 9 }
circuitTrailSourcePort OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this circuit's source port/interface."
::= { circuitTrailEntry 10 }
circuitTrailDestinationNetwork OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this circuit's destination network."
::= { circuitTrailEntry 11 }
circuitTrailDestinationNE OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this circuit's destination NE. See neTable."
::= { circuitTrailEntry 12 }
circuitTrailDestinationBoard OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this circuit's destination board. See boardTable."
::= { circuitTrailEntry 13 }
circuitTrailDestinationPort OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of this circuit's destination port/interface."
::= { circuitTrailEntry 14 }
circuitTrailDatabaseId OBJECT-TYPE
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is a unique ID to identifiy a row of this table. The id's negatives represents back path."
::= { circuitTrailEntry 15 }
circuitTrailRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The RowStatus of this entry."
::= { circuitTrailEntry 16 }
networkAlarmStartNotification NOTIFICATION-TYPE
OBJECTS { networkAlarmSeverity, networkAlarmKey, networkAlarmGroup, networkAlarmStart, networkAlarmNetworkName, networkAlarmResource, networkAlarmLayer, networkAlarmNeName, networkAlarmBoardName, networkAlarmName, networkAlarmType, networkAlarmNeNameSource, networkAlarmBoardNameSource, networkAlarmPortNameSource, networkAlarmNeNameDestination, networkAlarmBoardNameDestination, networkAlarmPortNameDestination, networkAlarmAck }
STATUS current
DESCRIPTION "Start of an alarm. Contains all the information of the alarm and should be used for logging purposes."
::= { metropad3 16 }
networkAlarmEndNotification NOTIFICATION-TYPE
OBJECTS { networkAlarmSeverity, networkAlarmKey, networkAlarmGroup, networkAlarmStart, networkAlarmEnd, networkAlarmNetworkName, networkAlarmResource, networkAlarmLayer, networkAlarmNeName, networkAlarmBoardName, networkAlarmName, networkAlarmType, networkAlarmNeNameSource, networkAlarmBoardNameSource, networkAlarmPortNameSource, networkAlarmNeNameDestination, networkAlarmBoardNameDestination, networkAlarmPortNameDestination, networkAlarmAck }
STATUS current
DESCRIPTION "End of an alarm. Contains all the information of the alarm and should be used for logging purposes."
::= { metropad3 17 }
networkAlarmAckNotification NOTIFICATION-TYPE
OBJECTS { networkAlarmSeverity, networkAlarmKey, networkAlarmGroup, networkAlarmStart, networkAlarmEnd, networkAlarmNetworkName, networkAlarmResource, networkAlarmLayer, networkAlarmNeName, networkAlarmBoardName, networkAlarmName, networkAlarmType, networkAlarmAck, networkAlarmAckDate, networkAlarmAckUser }
STATUS current
DESCRIPTION "Acknowledgement of an alarm. The alarm may not be terminated."
::= { metropad3 18 }
serverMasterIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It corresponds to the IP Address of the configured Master Server."
::= { serverStatus 1 }
serverSlaveIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It corresponds to the IP Address of the configured Slave Server."
::= { serverStatus 2 }
serverIsActive OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It corresponds to the IP Address of the current server which is as active."
::= { serverStatus 3 }
serverVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It has the version of the Padtec Network Management System."
::= { serverStatus 4 }
serverBuild OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION " It has the number of the build at the following notation yyyymmdd. Therefore, this field has a value like yyyymmdd. Where yyyy corresponds to the year, mm to the month (1..12) and dd to the day (1..31)."
::= { serverStatus 5 }
serverUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It describes the period of time that happened since the current Active Master is running."
::= { serverStatus 6 }
serverSo OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It describes the operating system on whoch the server is being installed."
::= { serverStatus 7 }
serverFreeDiskSpace OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It has the total of free space at the partition on which the server is running. This partition to be monitored can be configured at the Padtec Network Management System. Padtec strongly advice to set this partittion to that one on which the database keep the data tables stored."
::= { serverStatus 8 }
serverSync OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It identifies if the master and slave servers have the database synchronized."
::= { serverStatus 9 }
networkEventLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF NetworkEventLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table has the events which are raised by Padtec Network Management System."
::= { metropad3 19 }
networkEventLogEntry OBJECT-TYPE
SYNTAX NetworkEventLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The event which is raised by Padtec Network Management System."
INDEX { networkEventLogId }
::= { networkEventLogTable 1 }
NetworkEventLogEntry ::= SEQUENCE {
networkEventLogId Integer32,
networkEventLogTime DateAndTime,
networkEventLogResourceType INTEGER,
networkEventLogResourceName OCTET STRING,
networkEventLogAction INTEGER,
networkEventLogRowStatus RowStatus
}
networkEventLogId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 2147483647 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "It is unique ID to identifiy a row of this table."
::= { networkEventLogEntry 1 }
networkEventLogTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the Date and Time when the event happen."
::= { networkEventLogEntry 2 }
networkEventLogResourceType OBJECT-TYPE
SYNTAX INTEGER {network ( 1 ) , ots ( 2 ) , oms ( 3 ) , circuit ( 4 ), omsotsrelation( 5 ), circuitomsrelation( 6 )}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of the resource affected by this event."
::= { networkEventLogEntry 3 }
networkEventLogResourceName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of the resource affected by this event."
::= { networkEventLogEntry 4 }
networkEventLogAction OBJECT-TYPE
SYNTAX INTEGER { add ( 1 ) , change ( 2 ) , remove ( 3 ) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The executed action."
::= { networkEventLogEntry 5 }
networkEventLogRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The RowStatus of this entry."
::= { networkEventLogEntry 6 }
networkEventLogNotification NOTIFICATION-TYPE
OBJECTS { networkEventLogTime, networkEventLogResourceType, networkEventLogResourceName, networkEventLogAction, networkEventLogRowStatus }
STATUS current
DESCRIPTION "It corresponds to a notification when an event is raised by Padtec Network Management System."
::= { metropad3 20 }
networkAlarmChangeNotification NOTIFICATION-TYPE
OBJECTS { networkAlarmSeverity, networkAlarmKey, networkAlarmGroup, networkAlarmStart, networkAlarmNetworkName, networkAlarmResource, networkAlarmLayer, networkAlarmNeName, networkAlarmBoardName, networkAlarmName, networkAlarmType, networkAlarmNeNameSource, networkAlarmBoardNameSource, networkAlarmPortNameSource, networkAlarmNeNameDestination, networkAlarmBoardNameDestination, networkAlarmPortNameDestination, networkAlarmAck }
STATUS current
DESCRIPTION "Change of a network alarm. Contains all the information of a network alarm and should be used for logging purposes."
::= { metropad3 21 }
trailAssociationTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrailAssociationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table represents all the contained OTS belonging to the same OMS Trail."
::= { metropad3 22 }
trailAssociationEntry OBJECT-TYPE
SYNTAX TrailAssociationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The event which is raised by Padtec Network Management System."
INDEX { omsOtsAssociationTrailIdIndex }
::= { trailAssociationTable 1 }
TrailAssociationEntry ::= SEQUENCE {
omsOtsAssociationTrailIdIndex Integer32,
omsOtsAssociationOtsTrailId Integer32,
omsOtsAssociationOmsTrailId Integer32,
omsOtsAssociationRowStatus RowStatus
}
omsOtsAssociationTrailIdIndex OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 2147483647 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "It is unique ID to identifiy a row of this table."
::= { trailAssociationEntry 1 }
omsOtsAssociationOtsTrailId OBJECT-TYPE
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is unique ID to identifiy a row of the OTS Trail table. The id's negatives represents back path."
::= { trailAssociationEntry 2 }
omsOtsAssociationOmsTrailId OBJECT-TYPE
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is unique ID to identifiy a row of the OMS Trail table. The id's negatives represents back path."
::= { trailAssociationEntry 3 }
omsOtsAssociationRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The RowStatus of this entry."
::= { trailAssociationEntry 4 }
circuitAssociationOmsTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrailAssociationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table represents all the contained OTS belonging to the same OMS Trail."
::= { metropad3 23 }
circuitAssociationOmsEntry OBJECT-TYPE
SYNTAX CircuitAssociationOmsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The event which is raised by Padtec Network Management System."
INDEX { circuitOmsAssociationTrailIdIndex }
::= { circuitAssociationOmsTable 1 }
CircuitAssociationOmsEntry ::= SEQUENCE {
circuitOmsAssociationTrailIdIndex Integer32,
circuitOmsAssociationCircuitTrailId Integer32,
circuitOmsAssociationOmsTrailId Integer32,
circuitOmsAssociationRowStatus RowStatus
}
circuitOmsAssociationTrailIdIndex OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 2147483647 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "It is unique ID to identifiy a row of this table. The id's negatives represents back path."
::= { circuitAssociationOmsEntry 1 }
circuitOmsAssociationCircuitTrailId OBJECT-TYPE
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is unique ID to identifiy a row of the Circuit Trail table. The id's negatives represents back path."
::= { circuitAssociationOmsEntry 2 }
circuitOmsAssociationOmsTrailId OBJECT-TYPE
SYNTAX Integer32 ( -2147483648 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is unique ID to identifiy a row of the OMS Trail table. "
::= { circuitAssociationOmsEntry 3 }
circuitOmsAssociationRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The RowStatus of this entry."
::= { circuitAssociationOmsEntry 4 }
boardPerformanceTable OBJECT-TYPE
SYNTAX SEQUENCE OF BoardPerformanceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Contains all the measurements which are stored by Padtec Network Management System. "
::= { metropad3 26 }
boardPerformanceEntry OBJECT-TYPE
SYNTAX BoardPerformanceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A performance measure stored by Padtec Network Management System."
INDEX { boardPerformanceBoardPart, boardPerformanceBoardSerial, boardPerformanceType, boardPerformancePortNumber, boardPerformancePortType }
::= { boardPerformanceTable 1 }
BoardPerformanceEntry ::= SEQUENCE {
boardPerformanceBoardPart Integer32,
boardPerformanceBoardSerial Integer32,
boardPerformanceType INTEGER,
boardPerformancePortNumber Integer32,
boardPerformancePortType INTEGER,
boardPerformanceValue Integer32,
boardPerformanceRate OCTET STRING,
boardPerformanceTime DateAndTime,
boardPerformanceNeName OCTET STRING,
boardPerformanceNeMap OCTET STRING,
boardPerformanceRowStatus RowStatus
}
boardPerformanceBoardPart OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 2147483647 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "It is a number corresponding to the part number at the boardTable. Every performance measurement is associated with a board identified at boardTable."
::= { boardPerformanceEntry 1 }
boardPerformanceBoardSerial OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 2147483647 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "It is a number corresponding to the serial number at the boardTable. Every performance measurement is associated with a board identified at boardTable."
::= { boardPerformanceEntry 2 }
boardPerformanceType OBJECT-TYPE
SYNTAX INTEGER ( 1 .. 2147483647 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "It corresponds to the type of the performance measurement has been taken. See the list of types at the manual."
::= { boardPerformanceEntry 3 }
boardPerformancePortNumber OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 2147483647 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "It corresponds the port number of the Padtec Board on which the performance measurenebt has been taken."
::= { boardPerformanceEntry 4 }
boardPerformancePortType OBJECT-TYPE
SYNTAX INTEGER { client ( 1 ) , wdm ( 2 ) }
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "It corresponds to the type of port of the Padtec Board on which the performance measurement has been taken."
::= { boardPerformanceEntry 5 }
boardPerformanceValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It corresponds to the performance measurements multipled by 100, in such way that is possible to represent measurements with 2 number precisions. For instance, if the value is 12.25 dBm, then the corresponding value at this table will be 1225."
::= { boardPerformanceEntry 6 }
boardPerformanceRate OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It describes the performance measurements which are displayed at scientific notation. Therefore, all the error rates, transmission rates are mapped at this column."
::= { boardPerformanceEntry 7 }
boardPerformanceTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It corresponds to the Date and Time when the performance measurement was stored by the Padtec Network Management System."
::= { boardPerformanceEntry 8 }
boardPerformanceNeName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It is the name of NE which the correspondent board entry is placed."
::= { boardPerformanceEntry 9 }
boardPerformanceNeMap OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "It describes the map which contains the current NE Name."
::= { boardPerformanceEntry 10 }
boardPerformanceRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The RowStatus of this entry."
::= { boardPerformanceEntry 11 }
lightpadNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS
{
networkAlarmChangeNotification,
networkEventLogNotification,
networkAlarmAckNotification,
networkAlarmEndNotification,
networkAlarmStartNotification,
isStatusNotification,
isRecreateAlarmsNotification,
isAliveNotification,
eventNotification,
alarmEndNotification,
alarmStartNotification,
alarmAckNotification
}
STATUS current
DESCRIPTION
"The collection of notifications used to indicate lightpad MIB
data consistency and general status information."
::= { lightpadMIBGroups 1 }
lightpadGroup OBJECT-GROUP
OBJECTS {
uptimeAgente,
statusAgente,
neRowStatus,
neMap,
neNetwork,
neName
}
STATUS current
DESCRIPTION
"A collection of objects providing basic instrumentation and
control of an SNMPv2 entity."
::= { lightpadMIBGroups 2 }
boardPerformanceGroup OBJECT-GROUP
OBJECTS {
boardPerformanceRowStatus,
boardPerformanceNeMap,
boardPerformanceNeName,
boardPerformanceTime,
boardPerformanceRate,
boardPerformanceValue
}
STATUS current
DESCRIPTION
"A collection of objects providing basic instrumentation and
control of an SNMPv2 entity."
::= { lightpadMIBGroups 3 }
circuitOmsAssociationGroup OBJECT-GROUP
OBJECTS {
circuitOmsAssociationRowStatus,
circuitOmsAssociationOmsTrailId,
circuitOmsAssociationCircuitTrailId
}
STATUS current
DESCRIPTION
"A collection of objects providing basic instrumentation and
control of an SNMPv2 entity."
::= { lightpadMIBGroups 4 }
omsOtsAssociationGroup OBJECT-GROUP
OBJECTS {
omsOtsAssociationRowStatus,
omsOtsAssociationOmsTrailId,
omsOtsAssociationOtsTrailId
}
STATUS current
DESCRIPTION
"A collection of objects providing basic instrumentation and
control of an SNMPv2 entity."
::= { lightpadMIBGroups 5 }
networkEventLogGroup OBJECT-GROUP
OBJECTS {
networkEventLogRowStatus,
networkEventLogAction,
networkEventLogResourceName,
networkEventLogResourceType,
networkEventLogTime
}
STATUS current
DESCRIPTION
"A collection of objects providing basic instrumentation and
control of an SNMPv2 entity."
::= { lightpadMIBGroups 6 }
serverGroup OBJECT-GROUP
OBJECTS {
serverSync,
serverFreeDiskSpace,
serverSo,
serverUpTime,
serverBuild,
serverVersion,
serverIsActive,
serverSlaveIp,
serverMasterIp
}
STATUS current
DESCRIPTION
"A collection of objects providing basic instrumentation and
control of an SNMPv2 entity."
::= { lightpadMIBGroups 7 }
circuitTrailGroup OBJECT-GROUP
OBJECTS {
circuitTrailRowStatus,
circuitTrailDatabaseId,
circuitTrailDestinationPort,
circuitTrailDestinationBoard,
circuitTrailDestinationNE,
circuitTrailDestinationNetwork,
circuitTrailSourcePort,
circuitTrailSourceBoard,
circuitTrailSourceNE,
circuitTrailSourceNetwork,
circuitTrailService,
circuitTrailClientId,
circuitTrailClientName,
circuitTrailDescription,
circuitTrailName
}
STATUS current
DESCRIPTION
"A collection of objects providing basic instrumentation and
control of an SNMPv2 entity."
::= { lightpadMIBGroups 8 }
omsTrailGroup OBJECT-GROUP
OBJECTS {
omsTrailRowStatus,
omsTrailDatabaseId,
omsTrailDestinationPort,
omsTrailDestinationBoard,
omsTrailDestinationNE,
omsTrailSourcePort,
omsTrailSourceBoard,
omsTrailSourceNE,
omsTrailDescription,
omsTrailName
}
STATUS current
DESCRIPTION
"A collection of objects providing basic instrumentation and
control of an SNMPv2 entity."
::= { lightpadMIBGroups 9 }
otsTrailGroup OBJECT-GROUP
OBJECTS {
otsTrailRowStatus,
otsTrailDatabaseId,
otsTrailDestinationPort,
otsTrailDestinationBoard,
otsTrailDestinationNE,
otsTrailSourcePort,
otsTrailSourceBoard,
otsTrailSourceNE,
otsTrailDistance,
otsTrailFiberType,
otsTrailDescription,
otsTrailName
}
STATUS current
DESCRIPTION
"A collection of objects providing basic instrumentation and
control of an SNMPv2 entity."
::= { lightpadMIBGroups 10 }
networkAlarmObjectGroup OBJECT-GROUP
OBJECTS {
networkAlarmRowStatus,
networkAlarmAckUser,
networkAlarmAckDate,
networkAlarmAck,
networkAlarmPortNameDestination,
networkAlarmBoardNameDestination,
networkAlarmNeNameDestination,
networkAlarmPortNameSource,
networkAlarmBoardNameSource,
networkAlarmNeNameSource,
networkAlarmType,
networkAlarmName,
networkAlarmBoardName,
networkAlarmNeName,
networkAlarmLayer,
networkAlarmResource,
networkAlarmNetworkName,
networkAlarmEnd,
networkAlarmStart,
networkAlarmGroup,
networkAlarmKey,
networkAlarmSeverity
}
STATUS current
DESCRIPTION
"A collection of objects providing basic instrumentation and
control of an SNMPv2 entity."
::= { lightpadMIBGroups 11 }
alarmsNotificationGroup OBJECT-GROUP
OBJECTS {
alarmsNotificationNeName,
alarmsNotificationBoardName,
alarmsNotificationBoardSerial,
alarmsNotificationBoardPart
}
STATUS current
DESCRIPTION
"A collection of objects providing basic instrumentation and
control of an SNMPv2 entity."
::= { lightpadMIBGroups 12 }
performanceGroup OBJECT-GROUP
OBJECTS {
performanceRowStatus,
performanceOid,
performanceNeMap,
performanceNeName,
performanceTime,
performanceRate,
performanceValue,
performancePortNumber,
performancePortType,
performanceType,
performanceBoardSerial,
performanceBoardPart
}
STATUS current
DESCRIPTION
"A collection of objects providing basic instrumentation and
control of an SNMPv2 entity."
::= { lightpadMIBGroups 13 }
eventGroup OBJECT-GROUP
OBJECTS {
eventRowStatus,
eventNeMap,
eventNeName,
eventTime,
eventBoardSlot,
eventBoardSubRack,
eventBoardRackPosition,
eventBoardSerial,
eventBoardPart,
eventName,
eventType
}
STATUS current
DESCRIPTION
"A collection of objects providing basic instrumentation and
control of an SNMPv2 entity."
::= { lightpadMIBGroups 14 }
alarmGroup OBJECT-GROUP
OBJECTS {
alarmRowStatus,
alarmNeMap,
alarmNeName,
alarmAckUser,
alarmAckDescription,
alarmAckDate,
alarmEnd,
alarmStart,
alarmBoardSlot,
alarmBoardSubRack,
alarmResource,
alarmBoardRackPosition,
alarmBoardSerial,
alarmBoardPart,
alarmName,
alarmSeverity,
alarmType,
alarmId
}
STATUS current
DESCRIPTION
"A collection of objects providing basic instrumentation and
control of an SNMPv2 entity."
::= { lightpadMIBGroups 15 }
boardGroup OBJECT-GROUP
OBJECTS {
boardRowStatus,
boardState,
boardNeMap,
boardNeName,
boardVersion,
boardSlot,
boardSubRack,
boardRackPosition,
boardDescription,
boardName,
boardModel,
boardSerial,
boardPart
}
STATUS current
DESCRIPTION
"A collection of objects providing basic instrumentation and
control of an SNMPv2 entity."
::= { lightpadMIBGroups 16 }
END