-- Title: Microsens private MIB for Generation 6 Ethernet Switches
|
|
-- NOTIFICATION MIB
|
|
-- Version: 0.11
|
|
-- Date: 3 May 2017
|
|
|
|
-- REVISION HISTORY:
|
|
-- REVISION "201206260000Z" 25 june 2012
|
|
-- DESCRIPTION "File creation"
|
|
|
|
-- ***********************************************************************
|
|
|
|
MICROSENS-G6-NOTIFICATION-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE, Integer32, enterprises
|
|
FROM SNMPv2-SMI
|
|
DisplayString, MacAddress FROM SNMPv2-TC
|
|
TRAP-TYPE FROM RFC-1215;
|
|
-- NOTIFICATION-GROUP FROM SNMPv2-CONF;
|
|
-- g6 FROM MICROSENS-G6-MIB
|
|
|
|
microsens MODULE-IDENTITY
|
|
LAST-UPDATED "201705030000Z"
|
|
ORGANIZATION "MICROSENS GmbH & Co. KG"
|
|
CONTACT-INFO
|
|
"Kueferstrasse 16
|
|
D-59067 Hamm
|
|
Germany
|
|
support@microsens.de
|
|
http://www.microsens.de"
|
|
DESCRIPTION
|
|
"Microsens private NOTIFICATION for Generation 6 Software Platform"
|
|
|
|
|
|
REVISION "201705030000Z"
|
|
DESCRIPTION "Added event 125 and renamed SmartOfficeTraps"
|
|
|
|
REVISION "201702230000Z"
|
|
DESCRIPTION "Added event 106 to 124"
|
|
|
|
REVISION "201510050000Z"
|
|
DESCRIPTION "Added event 101 to 105"
|
|
|
|
REVISION "201504240000Z"
|
|
DESCRIPTION "Added event 97 to 100"
|
|
|
|
REVISION "201502020000Z"
|
|
DESCRIPTION "Added event 88 to 96"
|
|
|
|
REVISION "201408080000Z"
|
|
DESCRIPTION "Added event 87"
|
|
|
|
REVISION "201403170000Z"
|
|
DESCRIPTION "Added event 86 and MAC Binding to MAC related events"
|
|
|
|
REVISION "201311130000Z"
|
|
DESCRIPTION "Added event 49 to 85"
|
|
|
|
REVISION "201208260000Z"
|
|
DESCRIPTION "File creation"
|
|
|
|
::= { enterprises 3181 }
|
|
|
|
-- microsens OBJECT IDENTIFIER ::= { enterprises 3181 }
|
|
managedSwitches OBJECT IDENTIFIER ::= { microsens 10 }
|
|
g6 OBJECT IDENTIFIER ::= { managedSwitches 6 }
|
|
|
|
g6TrapGroup OBJECT IDENTIFIER ::= { g6 1 }
|
|
g6Trap OBJECT IDENTIFIER ::= { g6TrapGroup 1 }
|
|
g6TrapObjects OBJECT IDENTIFIER ::= { g6TrapGroup 2 }
|
|
|
|
|
|
-- ***********************************************************************
|
|
-- ***********************************************************************
|
|
-- ***********************************************************************
|
|
-- Define Objects to be appended with the traps / notifications
|
|
|
|
g6TrapObjEventName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Event name as text string."
|
|
::= { g6TrapObjects 1 }
|
|
|
|
|
|
g6TrapObjGroupName OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
internal (0), -- Not for customer use. Will not occure
|
|
debug (2),
|
|
test (3),
|
|
reset (4),
|
|
firmware (5),
|
|
system (6),
|
|
config (7),
|
|
login (8),
|
|
auth (9),
|
|
power (10),
|
|
temperature (11),
|
|
link (12),
|
|
sfp (13),
|
|
poe (14),
|
|
ring (15),
|
|
ntp (16),
|
|
signals (17),
|
|
script (18),
|
|
filter (19),
|
|
lacp (20),
|
|
app (21),
|
|
cable (22),
|
|
security (23),
|
|
msp1000 (24),
|
|
backup (25),
|
|
fan (26),
|
|
messaging (27),
|
|
terminalserver (28),
|
|
smartoffice (29)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Event group as text string."
|
|
::= { g6TrapObjects 2 }
|
|
|
|
|
|
g6TrapObjRelevance OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
positive(0),
|
|
negative(1),
|
|
information(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "pos neg info"
|
|
::= { g6TrapObjects 3 }
|
|
|
|
|
|
g6TrapObjSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (0), -- No Output
|
|
debug (1), -- Internal system debugging information
|
|
info (2), -- Information with no important consequnces
|
|
notice (3), -- Notification about normal occurance
|
|
warning (4), -- Warning about a normal problem
|
|
error (5), -- Unexpected error has occured
|
|
critical (6), -- Critical error which compromises traffic or stability
|
|
alert (7), -- Very important error condition
|
|
emergency (8) -- Highest possible error condition (unused)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Severity level of this event."
|
|
::= { g6TrapObjects 4 }
|
|
|
|
|
|
g6TrapObjSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unit(0),
|
|
port(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Unit or port related event."
|
|
::= { g6TrapObjects 5 }
|
|
|
|
|
|
g6TrapObjSysName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "User defined system name of the device originating this event."
|
|
::= { g6TrapObjects 6 }
|
|
|
|
|
|
g6TrapObjPortId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Port identification in snmp compliant integer format. Value is calculated as (slot * 100) + port."
|
|
::= { g6TrapObjects 7 }
|
|
|
|
|
|
g6TrapObjPortString OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Port identification in slot/port notation."
|
|
::= { g6TrapObjects 8 }
|
|
|
|
|
|
g6TrapObjPortAlias OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Port identification using a possible user assigned alias or nickname."
|
|
::= { g6TrapObjects 9 }
|
|
|
|
|
|
g6TrapObjDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Detailed human readable full description of the event."
|
|
::= { g6TrapObjects 10 }
|
|
|
|
|
|
g6TrapObjMac OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "MAC address related with authentication trap."
|
|
::= { g6TrapObjects 11 }
|
|
|
|
|
|
g6TrapObjVlanId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Associated VLAN id."
|
|
::= { g6TrapObjects 12 }
|
|
|
|
|
|
g6TrapObjOfficeGroupName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "SmartOffice actor or sensor group name."
|
|
::= { g6TrapObjects 13 }
|
|
|
|
|
|
g6TrapObjAvgValue OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "SmartOffice group data value. Contains the average value of all elements in the same group"
|
|
::= { g6TrapObjects 14 }
|
|
|
|
|
|
g6TrapObjTotalValue OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "SmartOffice group data value. Contains the total value of all elements in the same group"
|
|
::= { g6TrapObjects 15 }
|
|
|
|
-- ***************************************************************************************************************
|
|
-- ***************************************************************************************************************
|
|
-- ***************************************************************************************************************
|
|
-- Define the Traps themselves
|
|
|
|
-- DEBUG
|
|
g6TrapDebug NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Internal Debug Messages."
|
|
::= { g6Trap 3 }
|
|
|
|
-- ALIVE_TEST
|
|
g6TrapAliveTest NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Can be used to check out event and notification system with no effect to the system operation."
|
|
::= { g6Trap 4 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- FIRMWARE_UPDATE_OK
|
|
g6TrapFirmwareUpdateOk NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Firmware installation has successfully taken place."
|
|
::= { g6Trap 5 }
|
|
|
|
-- FIRMWARE_UPDATE_FAIL
|
|
g6TrapFirmwareUpdateFail NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Firmware installation has FAILED."
|
|
::= { g6Trap 6 }
|
|
|
|
-- LICENSE_VIOLATION
|
|
g6TrapLicenseViolation NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Firmware is used for which no license has been granted. Please contact sales representant."
|
|
::= { g6Trap 7 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- COLDSTART
|
|
g6TrapColdStart NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "The device has booted. Data transmission was interrupted."
|
|
::= { g6Trap 8 }
|
|
|
|
-- WARMSTART
|
|
g6TrapWarmStart NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "The device has (partially) booted without interupting data transmission services."
|
|
::= { g6Trap 9 }
|
|
|
|
-- FACTORY_RESET
|
|
g6TrapFactoryReset NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Configuration factory reset is executed via local push button on the device."
|
|
::= { g6Trap 10 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- CONFIGURATION_LOADED
|
|
g6TrapConfigurationLoaded NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "All or a specific configuration file(s) has been restored and activated."
|
|
::= { g6Trap 11 }
|
|
|
|
-- CHANGE_CONFIG
|
|
g6TrapChangeConfig NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A configuration parameter has been modified and activated."
|
|
::= { g6Trap 12 }
|
|
|
|
-- CHANGE_OFFLINE_CONFIG
|
|
g6TrapChangeOfflineConfig NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "An offline configuration parameter has been modified. The running system is not affected."
|
|
::= { g6Trap 13 }
|
|
|
|
-- ACTION_RESPONSE
|
|
g6TrapActionResponse NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Not a customer event. Contains the reponse string to an action command."
|
|
::= { g6Trap 14 }
|
|
|
|
-- COMMIT_CONFIG
|
|
g6TrapCommitConfig NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Not a customer event. Recent configuration changes should now be stored and activated."
|
|
::= { g6Trap 15 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- POWER_SUPPLY_OK
|
|
g6TrapPowerSupplyOk NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Power supply has been restored. Applies to units with redundant supplies only."
|
|
::= { g6Trap 16 }
|
|
|
|
-- POWER_SUPPLY_FAIL
|
|
g6TrapPowerSupplyFail NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Power supply has FAILED. Applies to units with redundant supplies only."
|
|
::= { g6Trap 17 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- LOGIN
|
|
g6TrapLogin NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "An operator has logged onto the system."
|
|
::= { g6Trap 18 }
|
|
|
|
-- LOGOUT
|
|
g6TrapLogout NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "An operator has logged off from the system."
|
|
::= { g6Trap 19 }
|
|
|
|
-- LOGIN_ATTEMPT
|
|
g6TrapLoginAttempt NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "An operator login has failed due to invalid login or password."
|
|
::= { g6Trap 20 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- LINK_UP
|
|
g6TrapLinkUp NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A port has gone online and is ready to transport data."
|
|
::= { g6Trap 21 }
|
|
|
|
-- LINK_DOWN
|
|
g6TrapLinkDown NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A port has gone down. Data transport on this port is no longer possible."
|
|
::= { g6Trap 22 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- RING_NORMAL
|
|
g6TrapRingNormal NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A ring is back to normal operation. Protection is available."
|
|
::= { g6Trap 23 }
|
|
|
|
-- RING_BACKUP
|
|
g6TrapRingBackup NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A ring has switched to the redundant backup path."
|
|
::= { g6Trap 24 }
|
|
|
|
-- RING_FAILURE
|
|
g6TrapRingFailure NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A ring has FAILED. Normal and backup path are unavailable."
|
|
::= { g6Trap 25 }
|
|
|
|
-- COUPLING_STATE
|
|
g6TrapCouplingState NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Coupling controller state change."
|
|
::= { g6Trap 26 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- TEMPERATURE_OK
|
|
g6TrapTemperatureOk NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Operating temperature is within acceptable limits."
|
|
::= { g6Trap 27 }
|
|
|
|
-- TEMPERATURE_WARNING
|
|
g6TrapTemperatureWarning NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Operating temperature is low or high. Performance my be degraded. Do not run under this condition for prolonged time."
|
|
::= { g6Trap 28 }
|
|
|
|
-- TEMPERATURE_FAILURE
|
|
g6TrapTemperatureFailure NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Operating temperature is too low or too high. The unit may switch itself off to protect itself anytime soon."
|
|
::= { g6Trap 29 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- MAC_ACCEPTED
|
|
g6TrapMacAccepted NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjMac, g6TrapObjVlanId, g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A MAC address has been authorized."
|
|
::= { g6Trap 30 }
|
|
|
|
-- MAC_AUTH_ERROR
|
|
g6TrapMacAuthError NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjMac, g6TrapObjVlanId, g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "MAC authorization error."
|
|
::= { g6Trap 31 }
|
|
|
|
-- MAC_BLOCKED
|
|
g6TrapMacBlocked NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjMac, g6TrapObjVlanId, g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A MAC address has been blocked."
|
|
::= { g6Trap 32 }
|
|
|
|
-- MACS_BLOCKED_VLAN
|
|
g6TrapMacBlockedVlan NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjMac, g6TrapObjVlanId, g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A MAC address has been blocked. Assigned to unauthorized VLAN."
|
|
::= { g6Trap 33 }
|
|
|
|
-- MAC_DISCONNECTED
|
|
g6TrapMacDisconnected NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjMac, g6TrapObjVlanId, g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A MAC address has been disconnected."
|
|
::= { g6Trap 34 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- SFP_INSERTED
|
|
g6TrapSfpInserted NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "An SFP (pluggable optical or electrical port module) has been inserted."
|
|
::= { g6Trap 35 }
|
|
|
|
-- SFP_REMOVED
|
|
g6TrapSfpRemoved NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "An SFP (pluggable optical or electrical port module) has been removed from the device."
|
|
::= { g6Trap 36 }
|
|
|
|
-- SFP_SIGNAL_PRESENT
|
|
g6TrapSfpSignalPresent NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "An SFP (pluggable optical or electrical port module) has detected an optical receive signal."
|
|
::= { g6Trap 37 }
|
|
|
|
-- SFP_SIGNAL_LOSS
|
|
g6TrapSfpSignalLoss NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "An SFP (pluggable optical or electrical port module) has lost its receive signal."
|
|
::= { g6Trap 38 }
|
|
|
|
-- SFP_SIGNAL_CHANGE
|
|
g6TrapSfpSignalChange NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "An SFP (pluggable optical or electrical port module) has detected a change in the optical input power level."
|
|
::= { g6Trap 39 }
|
|
|
|
-- SFP_MISMATCH
|
|
g6TrapSfpMismatch NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "An SFP (pluggable optical or electrical port module) has been inserted which does not match the required feature(s)."
|
|
::= { g6Trap 40 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- POE_CONNECT
|
|
g6TrapPoeConnect NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A POE (Power over Ethernet) device is connected an powered."
|
|
::= { g6Trap 41 }
|
|
|
|
-- POE_VOLTAGE
|
|
g6TrapPoeVoltage NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "The POE (Power over Ethernet) operating voltage is too low."
|
|
::= { g6Trap 42 }
|
|
|
|
-- POE_ERROR
|
|
g6TrapPoeError NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A POE (Power over Ethernet) error has occurred."
|
|
::= { g6Trap 43 }
|
|
|
|
-- POE_CLASSMISMATCH
|
|
g6TrapPoeClassmismatch NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A POE (Power over Ethernet) powered device requires a power level not enabled or available at this port."
|
|
::= { g6Trap 44 }
|
|
|
|
-- POE_DISCONNECT
|
|
g6TrapPoeDisconnect NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A POE (Power over Ethernet) device has been disconnected."
|
|
::= { g6Trap 45 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- NTP_FAIL
|
|
g6TrapNtpFail NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "The NTP client (Network Time Protocol) has a failure condition."
|
|
::= { g6Trap 46 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- HARDWARE_ERROR
|
|
g6TrapHardwareError NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A hardware error has been detected."
|
|
::= { g6Trap 47 }
|
|
|
|
|
|
-- SOFTWARE_ERROR
|
|
g6TrapSoftwareError NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A software error has occured."
|
|
::= { g6Trap 48 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- BUTTON_PRESSED
|
|
g6TrapButtonPressed NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "System button pressed."
|
|
::= { g6Trap 49 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- SIGNALS
|
|
g6TrapInputSignalNormal NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "An external input signal has been deactivated and returned to normal state."
|
|
::= { g6Trap 67 }
|
|
|
|
g6TrapInputSignalActivated NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "An external input signal has been activated."
|
|
::= { g6Trap 68 }
|
|
|
|
g6TrapOutputRelayNormal NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A relay output signal has been deactivated and returned to normal state."
|
|
::= { g6Trap 69 }
|
|
|
|
g6TrapOutputRelayActivated NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "An external input signal has been deactivated and returned to normal state."
|
|
::= { g6Trap 70 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- FILTER
|
|
g6TrapPacketIntercepted NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Special filter has intercepted a data packet."
|
|
::= { g6Trap 71 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- SCRIPT
|
|
g6TrapScriptUnitPositive NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A positive unit related user defined event created by script or app."
|
|
::= { g6Trap 72 }
|
|
|
|
g6TrapScriptUnitNegative NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A negative unit related user defined event created by script or app."
|
|
::= { g6Trap 73 }
|
|
|
|
g6TrapScriptPortPositive NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A positive port related user defined event created by script or app."
|
|
::= { g6Trap 74 }
|
|
|
|
g6TrapScriptPortNegative NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A negative port related user defined event created by script or app."
|
|
::= { g6Trap 75 }
|
|
|
|
g6TrapScriptExecuted NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A user defined script execution started."
|
|
::= { g6Trap 76 }
|
|
|
|
g6TrapScriptError NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Script execution error of a user defined script."
|
|
::= { g6Trap 77 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- LINK
|
|
g6TrapLoopRemoved NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Cable loop removed. Port unblocked."
|
|
::= { g6Trap 78 }
|
|
|
|
g6TrapLoopDetected NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Cable loop detected. Port blocked."
|
|
::= { g6Trap 79 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- LACP
|
|
g6TrapLacpConnect NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Aggregated link established."
|
|
::= { g6Trap 80 }
|
|
|
|
g6TrapLacpDisconnect NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Aggregated link down."
|
|
::= { g6Trap 81 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- APP
|
|
g6TrapAppInstalled NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "App installed ok."
|
|
::= { g6Trap 82 }
|
|
|
|
g6TrapAppInstallationFail NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "App installation has failed."
|
|
::= { g6Trap 83 }
|
|
|
|
g6TrapAppDeinstalled NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "App deinstalled."
|
|
::= { g6Trap 84 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- CABLE
|
|
g6TrapCableChangeDetected NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Change in cable termination detected."
|
|
::= { g6Trap 85 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- IMPLAUSIBLE CONFIG
|
|
g6TrapImplausibleConfig NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Implausible configuration detected"
|
|
::= { g6Trap 86 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- NETWORK ATTACK
|
|
g6TrapNetworkAttack NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Potential network attack detected"
|
|
::= { g6Trap 87 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- SYSTEM
|
|
g6TrapModuleInserted NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A hardware module has been inserted into the system."
|
|
::= { g6Trap 88 }
|
|
|
|
g6TrapModuleRemoved NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A hardware module has been removed from the system."
|
|
::= { g6Trap 89 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- MSP1000
|
|
g6TrapMsp1000UnitPositive NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A positive MSP1000 unit related event has occured."
|
|
::= { g6Trap 90 }
|
|
|
|
g6TrapMsp1000UnitNegative NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A negative MSP1000 unit related event has occured."
|
|
::= { g6Trap 91 }
|
|
|
|
g6TrapMsp1000PortPositive NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A positive MSP1000 port related event has occured."
|
|
::= { g6Trap 92 }
|
|
|
|
g6TrapMsp1000PortNegative NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A negative MSP1000 port related event has occured."
|
|
::= { g6Trap 93 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- BACKUP
|
|
g6TrapBackupTerminated NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Backup path not required."
|
|
::= { g6Trap 94 }
|
|
|
|
g6TrapBackupEngaged NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Backup path has been engaged."
|
|
::= { g6Trap 95 }
|
|
|
|
g6TrapBackupFailure NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Backup path could not be completed."
|
|
::= { g6Trap 96 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- FAN
|
|
g6TrapFanOk NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Cooling fan operating normally."
|
|
::= { g6Trap 97 }
|
|
|
|
g6TrapFanDegraded NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Cooling fan degraded. Replace fan soon."
|
|
::= { g6Trap 98 }
|
|
|
|
g6TrapFanFailure NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Cooling fan failed. Replace fan immediately"
|
|
::= { g6Trap 99 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- MESSAGING
|
|
g6TrapIncomingAlert NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Externally received HTTP_GET_REQUEST or received SNMP TRAP."
|
|
::= { g6Trap 100 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- CABLE
|
|
g6TrapCableTerminationEstablished NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Cable termination established. Possible reason: A terminated remote device was connected to the cable."
|
|
::= { g6Trap 101 }
|
|
|
|
g6TrapCableTerminationLost NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Cable termination lost. Possible reason: A terminated remote device was disconnected from the cable or the cable was locally unplugged."
|
|
::= { g6Trap 102 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- TERMINAL_SERVER
|
|
g6TrapTerminalServerConnected NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Terminal server connected foreign host to local serial port."
|
|
::= { g6Trap 103 }
|
|
|
|
g6TrapTerminalServerDisconnected NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Terminal server disconnected foreign host from local serial port."
|
|
::= { g6Trap 104 }
|
|
|
|
g6TrapTerminalServerFail NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Terminal server failed in connecting foreign host to local serial port."
|
|
::= { g6Trap 105 }
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- SMART_OFFICE
|
|
g6TrapSensorGroupChange NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjOfficeGroupName, g6TrapObjAvgValue, g6TrapObjTotalValue,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Sensor group values have changed."
|
|
::= { g6Trap 108 }
|
|
|
|
g6TrapActorGroupChangeRequest NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Actor group is requested to change to a new value."
|
|
::= { g6Trap 110 }
|
|
|
|
g6TrapRegisterSmartDevice NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A new smart device is registered."
|
|
::= { g6Trap 111 }
|
|
|
|
g6TrapUpdateSmartDevice NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A smart device has changed its status."
|
|
::= { g6Trap 112 }
|
|
|
|
g6TrapRegisterSmartAttribute NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A new smart attribute is registered."
|
|
::= { g6Trap 115 }
|
|
|
|
g6TrapUnregisterSmartDevice NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A smart device is unregistered."
|
|
::= { g6Trap 117 }
|
|
|
|
g6TrapUnregisterSmartAttribute NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A smart attribute is unregistered."
|
|
::= { g6Trap 118 }
|
|
|
|
g6TrapSingleActorChange NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "An individual actor is set to a new value."
|
|
::= { g6Trap 119 }
|
|
|
|
g6TrapActorGroupChanged NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjOfficeGroupName, g6TrapObjAvgValue,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "An actor group has changed to a new value."
|
|
::= { g6Trap 120 }
|
|
|
|
g6TrapSmartOfficeInitializing NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Smart Office is being initialized."
|
|
::= { g6Trap 121 }
|
|
|
|
g6TrapSmartOfficeStarted NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Smart Office is started and ready."
|
|
::= { g6Trap 122 }
|
|
|
|
g6TrapSmartOfficeStopped NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "Smart Office is being stopped."
|
|
::= { g6Trap 123 }
|
|
|
|
g6TrapSmartOfficeError NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjSysName,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "A Smart Office error has occured."
|
|
::= { g6Trap 124 }
|
|
|
|
|
|
-- ===============================================================================================================
|
|
|
|
-- OTDR_MEASUREMENTS
|
|
g6TrapOtdrMeasurements NOTIFICATION-TYPE
|
|
OBJECTS { g6TrapObjEventName, g6TrapObjGroupName, g6TrapObjRelevance,
|
|
g6TrapObjSeverity, g6TrapObjSource,
|
|
g6TrapObjPortId, g6TrapObjPortString, g6TrapObjPortAlias,
|
|
g6TrapObjDescription }
|
|
STATUS current
|
|
DESCRIPTION "An OTDR measurement has taken place and detected a change in the optical characteristics of the cable."
|
|
::= { g6Trap 125 }
|
|
|
|
-- ===============================================================================================================
|
|
END
|