1412 lines
39 KiB
Plaintext
1412 lines
39 KiB
Plaintext
MICROSENS-CWDM8-MIB --{ iso org(3) dod(6) internet(1) private(4) enterprises(1) microsens(3181) }
|
|
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
DisplayString FROM SNMPv2-TC
|
|
TRAP-TYPE FROM RFC-1215
|
|
enterprises, OBJECT-TYPE, IpAddress, Counter, Gauge, TimeTicks
|
|
FROM RFC1155-SMI;
|
|
|
|
-- Title: Microsens MIB/ 8-Channel-CWDM
|
|
-- Version : 1.0
|
|
-- Date : 02.07.2002
|
|
-- By: Joerg Johann
|
|
-- File: miccwdm8.mib
|
|
|
|
microsens OBJECT IDENTIFIER ::= { enterprises 3181 }
|
|
|
|
cwdm OBJECT IDENTIFIER ::= { microsens 6 }
|
|
|
|
eightChannelCwdm OBJECT IDENTIFIER ::= { cwdm 4 }
|
|
|
|
|
|
-- device status table
|
|
|
|
deviceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DeviceList
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table describes the device-status of the CWDM-system."
|
|
::= { eightChannelCwdm 1 }
|
|
|
|
deviceTableEntry OBJECT-TYPE
|
|
SYNTAX DeviceList
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry in the port table."
|
|
INDEX
|
|
{ deviceId } ::= { deviceTable 1 }
|
|
|
|
DeviceList ::= SEQUENCE {
|
|
deviceId INTEGER,
|
|
deviceArtNo DisplayString,
|
|
deviceSerNo DisplayString,
|
|
deviceDesc DisplayString,
|
|
deviceTemperature INTEGER,
|
|
deviceTempAlarmThreshold INTEGER,
|
|
deviceTempAlarm INTEGER,
|
|
deviceTempShutdown INTEGER,
|
|
deviceTrPowerFailureAlarm INTEGER,
|
|
deviceMinorAlarm INTEGER,
|
|
deviceMajorAlarm INTEGER
|
|
}
|
|
|
|
deviceId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the device id."
|
|
::= { deviceTableEntry 1 }
|
|
|
|
deviceArtNo OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the article number of the device."
|
|
::= { deviceTableEntry 2 }
|
|
|
|
deviceSerNo OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the serial number of the device."
|
|
::= { deviceTableEntry 3 }
|
|
|
|
deviceDesc OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry provides a detailed description of the device."
|
|
::= { deviceTableEntry 4 }
|
|
|
|
deviceTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the temperature of the device in degree centigrade."
|
|
::= { deviceTableEntry 5 }
|
|
|
|
deviceTempAlarmThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the current temperature-alarm threshold value of the device
|
|
in degree centigrade."
|
|
::= { deviceTableEntry 6 }
|
|
|
|
deviceTempAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
alarm (1),
|
|
no-alarm (0),
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes if a temperature-alarm condition has occurred or not."
|
|
::= { deviceTableEntry 7 }
|
|
|
|
deviceTempShutdown OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
alarm (1),
|
|
no-alarm (0),
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes if a temperature-shutdown condition has occurred or not."
|
|
::= { deviceTableEntry 8 }
|
|
|
|
deviceTrPowerFailureAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no-alarm (0),
|
|
alarm-channel-1-4 (1),
|
|
alarm-channel-5-8 (2),
|
|
alarm-channel-1-8 (3),
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes if a transceiver-board power-supply-alarm condition has occurred or not."
|
|
::= { deviceTableEntry 9 }
|
|
|
|
deviceMinorAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
alarm (1),
|
|
no-alarm (0),
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes if a minor-alarm condition has occurred or not."
|
|
::= { deviceTableEntry 10 }
|
|
|
|
deviceMajorAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
alarm (1),
|
|
no-alarm (0),
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes if a major-alarm condition has occurred or not."
|
|
::= { deviceTableEntry 11 }
|
|
|
|
|
|
|
|
-- port information table
|
|
|
|
portTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PortList
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table describes the port-status of the CWDM-system."
|
|
::= { eightChannelCwdm 2 }
|
|
|
|
portTableEntry OBJECT-TYPE
|
|
SYNTAX PortList
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry in the port table."
|
|
INDEX
|
|
{ portId } ::= { portTable 1 }
|
|
|
|
PortList ::= SEQUENCE {
|
|
portId INTEGER,
|
|
portChannelEnabled INTEGER,
|
|
portLinkThroughLocalLine INTEGER,
|
|
portLinkThroughLineLocal INTEGER,
|
|
portLocalModuleInstalled INTEGER,
|
|
portLineModuleInstalled INTEGER,
|
|
portLocalLink INTEGER,
|
|
portLineLink INTEGER,
|
|
portLocalTxFault INTEGER,
|
|
portLineTxFault INTEGER,
|
|
portLocalPowerFault INTEGER,
|
|
portLinePowerFault INTEGER,
|
|
portRateSelect INTEGER
|
|
}
|
|
|
|
portId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the port id. "
|
|
::= { portTableEntry 1 }
|
|
|
|
portChannelEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled (0),
|
|
enabled (1),
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the channel's status.
|
|
A value of 1 indicates that the channel is enabled,
|
|
a value of 0 indicates that the channel is not enabled."
|
|
::= { portTableEntry 2 }
|
|
|
|
portLinkThroughLocalLine OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled (0),
|
|
enabled (1),
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the local-line link-through-status of the port."
|
|
::= { portTableEntry 3 }
|
|
|
|
portLinkThroughLineLocal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled (0),
|
|
enabled (1),
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the line-local link-through-status of the port."
|
|
::= { portTableEntry 4 }
|
|
|
|
portLocalModuleInstalled OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
not-installed (0),
|
|
installed (1),
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes if a local transceiver module is installed or not."
|
|
::= { portTableEntry 5 }
|
|
|
|
portLineModuleInstalled OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
not-installed (0),
|
|
installed (1),
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes if a line transceiver module is installed or not."
|
|
::= { portTableEntry 6 }
|
|
|
|
portLocalLink OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (0),
|
|
on (1),
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the port's local link status."
|
|
::= { portTableEntry 7 }
|
|
|
|
portLineLink OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (0),
|
|
on (1),
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the port's line link status."
|
|
::= { portTableEntry 8 }
|
|
|
|
portLocalTxFault OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no-error (0),
|
|
error (1),
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the port's local-tx-fault status."
|
|
::= { portTableEntry 9 }
|
|
|
|
portLineTxFault OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no-error (0),
|
|
error (1),
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the port's line-tx-fault status."
|
|
::= { portTableEntry 10 }
|
|
|
|
portLocalPowerFault OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no-error (0),
|
|
error (1),
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the port's local-power-fault status."
|
|
::= { portTableEntry 11 }
|
|
|
|
portLinePowerFault OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no-error (0),
|
|
error (1),
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the port's line-power-fault status."
|
|
::= { portTableEntry 12 }
|
|
|
|
portRateSelect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
reduced (0),
|
|
full (1),
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the port's local data rate.
|
|
A value of 1 describes full data rate,
|
|
a value of 0 describes reduced data rate."
|
|
::= { portTableEntry 13 }
|
|
|
|
-- local module information table
|
|
|
|
localModuleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LocalModuleList
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table describes the local module status of the CWDM-system."
|
|
::= { eightChannelCwdm 3 }
|
|
|
|
localModuleTableEntry OBJECT-TYPE
|
|
SYNTAX LocalModuleList
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry in the local module table."
|
|
INDEX
|
|
{ localModuleId } ::= { localModuleTable 1 }
|
|
|
|
LocalModuleList ::= SEQUENCE {
|
|
localModuleId INTEGER,
|
|
localModuleConnector INTEGER,
|
|
localModuleTrCodeSonet INTEGER,
|
|
localModuleTrCodeGigabit INTEGER,
|
|
localModuleTrCodeFbLinkLength INTEGER,
|
|
localModuleTrCodeFbTrTech INTEGER,
|
|
localModuleTrCodeFbTrMedia INTEGER,
|
|
localModuleTrCodeFbSpeed INTEGER,
|
|
localModuleBrNominal INTEGER,
|
|
localModuleLength9km INTEGER,
|
|
localModuleLength9m INTEGER,
|
|
localModuleLength50 INTEGER,
|
|
localModuleLength62 INTEGER,
|
|
localModuleLengthCopper INTEGER,
|
|
localModuleVendorSN DisplayString,
|
|
localModuleDateCode DisplayString,
|
|
localModuleLaserCurrent INTEGER,
|
|
localModuleTransmittedPower INTEGER,
|
|
localModuleReceivedPower INTEGER,
|
|
localModuleLaserTemperature INTEGER,
|
|
localModuleVoltage INTEGER
|
|
}
|
|
|
|
localModuleId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the local module id. "
|
|
::= { localModuleTableEntry 1 }
|
|
|
|
localModuleConnector OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
sc (1),
|
|
style1-copper (2),
|
|
style2-copper (3),
|
|
bnc-tnc (4),
|
|
coaxial-headers (5),
|
|
fiberjack (6),
|
|
lc (7),
|
|
mt-rj (8),
|
|
mu (9),
|
|
sg (10),
|
|
opticalpigtail (11),
|
|
hssdc2 (32),
|
|
copperpigtail (33)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the connector-type of the port."
|
|
::= { localModuleTableEntry 2 }
|
|
|
|
localModuleTrCodeSonet OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
oc3-multi-mode-short-reach (1),
|
|
oc3-single-mode-intermediate-reach (2),
|
|
oc3-single-mode-long-reach (4),
|
|
oc12-multi-mode-short-reach (16),
|
|
oc12-single-mode-intermediate-reach (32),
|
|
oc12-single-mode-long-reach (64),
|
|
oc48-short-reach (128),
|
|
oc48-intermediate-reach (256),
|
|
oc48-long-reach (512)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the SONET compliance of the transceiver."
|
|
::= { localModuleTableEntry 3 }
|
|
|
|
localModuleTrCodeGigabit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
base-1000-sx (1),
|
|
base-1000-lx (2),
|
|
base-1000-cx (4),
|
|
base-1000-t (8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the Gigabit Ethernet compliance of the transceiver."
|
|
::= { localModuleTableEntry 4 }
|
|
|
|
localModuleTrCodeFbLinkLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
long-distance (1),
|
|
intermediate-distance (2),
|
|
short-distance (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the fibre channel link length of the transceiver."
|
|
::= { localModuleTableEntry 5 }
|
|
|
|
localModuleTrCodeFbTrTech OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
longwave-laser-LL (1),
|
|
shortwave-laser-OFC (2),
|
|
shortwave-laser-no-OFC (4),
|
|
electrical-intra-enclosure (8),
|
|
electrical-inter-enclosure (16),
|
|
longwave-laser-LC (32)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the fibre channel transmitter technology of the transceiver."
|
|
::= { localModuleTableEntry 6 }
|
|
|
|
localModuleTrCodeFbTrMedia OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
single-mode (1),
|
|
multi-mode-50 (4),
|
|
multi-mode-62-5 (8),
|
|
video-coax (16),
|
|
miniature-coax (32),
|
|
shielded-twisted-pair (64),
|
|
twin-axial-pair (128)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the fibre channel transmission media of the transceiver."
|
|
::= { localModuleTableEntry 7 }
|
|
|
|
localModuleTrCodeFbSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
speed-100MBytes-per-sec (1),
|
|
speed-200MBytes-per-sec (4),
|
|
speed-400MBytes-per-sec (16)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the fibre channel speed of the transceiver."
|
|
::= { localModuleTableEntry 8 }
|
|
|
|
localModuleBrNominal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the nominal bit rate, specified in units of 100 Megabits per second."
|
|
::= { localModuleTableEntry 9 }
|
|
|
|
localModuleLength9km OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the link length supported by the transceiver using single-mode fibers.
|
|
The value is in units of kilometers. A value of 255 means that the transceiver supports a
|
|
link length greater than 254 km. A value of zero means that the transceiver does not support
|
|
single-mode fibers."
|
|
::= { localModuleTableEntry 10 }
|
|
|
|
localModuleLength9m OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the link length supported by the transceiver using single-mode fibers.
|
|
The value is in units of 100 meters. A value of 255 means that the transceiver supports a
|
|
link length greater than 25.4 km. A value of zero means that the transceiver does not support
|
|
single-mode fibers."
|
|
::= { localModuleTableEntry 11 }
|
|
|
|
localModuleLength50 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the link length supported by the transceiver using 50 micron
|
|
multi-mode mode fibers. The value is in units of 10 meters.
|
|
A value of 255 means that the transceiver supports a link length greater than 2.54 km.
|
|
A value of zero means that the transceiver does not support 50 micron multi-mode fibers."
|
|
::= { localModuleTableEntry 12 }
|
|
|
|
localModuleLength62 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the link length supported by the transceiver using 62.5 micron
|
|
multi-mode mode fibers. The value is in units of 10 meters.
|
|
A value of 255 means that the transceiver supports a link length greater than 2.54 km.
|
|
A value of zero means that the transceiver does not support 62.5 micron multi-mode fibers."
|
|
::= { localModuleTableEntry 13 }
|
|
|
|
localModuleLengthCopper OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the link length supported by the transceiver using copper cables.
|
|
The value is in units of 1 meter.
|
|
A value of 255 means that the transceiver supports a link length greater than 254 m.
|
|
A value of zero means that the transceiver does not support copper cables."
|
|
::= { localModuleTableEntry 14 }
|
|
|
|
localModuleVendorSN OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the vendor's serial number of the transceiver."
|
|
::= { localModuleTableEntry 15 }
|
|
|
|
localModuleDateCode OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the vendor's date code in the [yymmdd]-format."
|
|
::= { localModuleTableEntry 16 }
|
|
|
|
localModuleLaserCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"This entry describes the transmitter laser's bias current in milli ampere."
|
|
::= { localModuleTableEntry 17 }
|
|
|
|
localModuleTransmittedPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"This entry describes the transmitter optical output power in micro watt."
|
|
::= { localModuleTableEntry 18 }
|
|
|
|
localModuleReceivedPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"This entry describes the transmitter optical received power in micro watt."
|
|
::= { localModuleTableEntry 19 }
|
|
|
|
localModuleLaserTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"This entry describes the laser temperature in degree centigrade."
|
|
::= { localModuleTableEntry 20 }
|
|
|
|
localModuleVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"This entry describes the transceiver supply voltage in mV."
|
|
::= { localModuleTableEntry 21 }
|
|
|
|
-- line module information table
|
|
|
|
lineModuleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LineModuleList
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table describes the line module status of the CWDM-system."
|
|
::= { eightChannelCwdm 4 }
|
|
|
|
lineModuleTableEntry OBJECT-TYPE
|
|
SYNTAX LineModuleList
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry in the line module table."
|
|
INDEX
|
|
{ lineModuleId } ::= { lineModuleTable 1 }
|
|
|
|
LineModuleList ::= SEQUENCE {
|
|
lineModuleId INTEGER,
|
|
lineModuleConnector INTEGER,
|
|
lineModuleTrCodeSonet INTEGER,
|
|
lineModuleTrCodeGigabit INTEGER,
|
|
lineModuleTrCodeFbLinkLength INTEGER,
|
|
lineModuleTrCodeFbTrTech INTEGER,
|
|
lineModuleTrCodeFbTrMedia INTEGER,
|
|
lineModuleTrCodeFbSpeed INTEGER,
|
|
lineModuleBrNominal INTEGER,
|
|
lineModuleLength9km INTEGER,
|
|
lineModuleLength9m INTEGER,
|
|
lineModuleLength50 INTEGER,
|
|
lineModuleLength62 INTEGER,
|
|
lineModuleLengthCopper INTEGER,
|
|
lineModuleVendorSN DisplayString,
|
|
lineModuleDateCode DisplayString,
|
|
lineModuleLaserCurrent INTEGER,
|
|
lineModuleTransmittedPower INTEGER,
|
|
lineModuleReceivedPower INTEGER,
|
|
lineModuleLaserTemperature INTEGER,
|
|
lineModuleVoltage INTEGER
|
|
}
|
|
|
|
lineModuleId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the line module id. "
|
|
::= { lineModuleTableEntry 1 }
|
|
|
|
lineModuleConnector OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
sc (1),
|
|
style1-copper (2),
|
|
style2-copper (3),
|
|
bnc-tnc (4),
|
|
coaxial-headers (5),
|
|
fiberjack (6),
|
|
lc (7),
|
|
mt-rj (8),
|
|
mu (9),
|
|
sg (10),
|
|
opticalpigtail (11),
|
|
hssdc2 (32),
|
|
copperpigtail (33)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the connector-type of the port."
|
|
::= { lineModuleTableEntry 2 }
|
|
|
|
lineModuleTrCodeSonet OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
oc3-multi-mode-short-reach (1),
|
|
oc3-single-mode-intermediate-reach (2),
|
|
oc3-single-mode-long-reach (4),
|
|
oc12-multi-mode-short-reach (16),
|
|
oc12-single-mode-intermediate-reach (32),
|
|
oc12-single-mode-long-reach (64),
|
|
oc48-short-reach (128),
|
|
oc48-intermediate-reach (256),
|
|
oc48-long-reach (512)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the SONET compliance of the transceiver."
|
|
::= { lineModuleTableEntry 3 }
|
|
|
|
lineModuleTrCodeGigabit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
base-1000-SX (1),
|
|
base-1000-LX (2),
|
|
base-1000-CX (4),
|
|
base-1000-T (8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the Gigabit Ethernet compliance of the transceiver."
|
|
::= { lineModuleTableEntry 4 }
|
|
|
|
lineModuleTrCodeFbLinkLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
long-distance (1),
|
|
intermediate-distance (2),
|
|
short-distance (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the fibre channel link length of the transceiver."
|
|
::= { lineModuleTableEntry 5 }
|
|
|
|
lineModuleTrCodeFbTrTech OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
longwave-laser-LL (1),
|
|
shortwave-laser-OFC (2),
|
|
shortwave-laser-no-OFC (4),
|
|
electrical-intra-enclosure (8),
|
|
electrical-inter-enclosure (16),
|
|
longwave-laser-LC (32)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the fibre channel transmitter technology of the transceiver."
|
|
::= { lineModuleTableEntry 6 }
|
|
|
|
lineModuleTrCodeFbTrMedia OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
single-mode (1),
|
|
multi-mode-50 (4),
|
|
multi-mode-62-5 (8),
|
|
video-coax (16),
|
|
miniature-coax (32),
|
|
shielded-twisted-pair (64),
|
|
twin-axial-pair (128)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the fibre channel transmission media of the transceiver."
|
|
::= { lineModuleTableEntry 7 }
|
|
|
|
lineModuleTrCodeFbSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
speed-100MBytes-per-sec (1),
|
|
speed-200MBytes-per-sec (4),
|
|
speed-400MBytes-per-sec (16)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the fibre channel speed of the transceiver."
|
|
::= { lineModuleTableEntry 8 }
|
|
|
|
lineModuleBrNominal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the nominal bit rate, specified in units of 100 Megabits per second."
|
|
::= { lineModuleTableEntry 9 }
|
|
|
|
lineModuleLength9km OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the link length supported by the transceiver using single-mode fibers.
|
|
The value is in units of kilometers. A value of 255 means that the transceiver supports a
|
|
link length greater than 254 km. A value of zero means that the transceiver does not support
|
|
single-mode fibers."
|
|
::= { lineModuleTableEntry 10 }
|
|
|
|
lineModuleLength9m OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the link length supported by the transceiver using single-mode fibers.
|
|
The value is in units of 100 meters. A value of 255 means that the transceiver supports a
|
|
link length greater than 25.4 km. A value of zero means that the transceiver does not support
|
|
single-mode fibers."
|
|
::= { lineModuleTableEntry 11 }
|
|
|
|
lineModuleLength50 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the link length supported by the transceiver using 50 micron
|
|
multi-mode mode fibers. The value is in units of 10 meters.
|
|
A value of 255 means that the transceiver supports a link length greater than 2.54 km.
|
|
A value of zero means that the transceiver does not support 50 micron multi-mode fibers."
|
|
::= { lineModuleTableEntry 12 }
|
|
|
|
lineModuleLength62 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the link length supported by the transceiver using 62.5 micron
|
|
multi-mode mode fibers. The value is in units of 10 meters.
|
|
A value of 255 means that the transceiver supports a link length greater than 2.54 km.
|
|
A value of zero means that the transceiver does not support 62.5 micron multi-mode fibers."
|
|
::= { lineModuleTableEntry 13 }
|
|
|
|
lineModuleLengthCopper OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the link length supported by the transceiver using copper cables.
|
|
The value is in units of 1 meter.
|
|
A value of 255 means that the transceiver supports a link length greater than 254 m.
|
|
A value of zero means that the transceiver does not support copper cables."
|
|
::= { lineModuleTableEntry 14 }
|
|
|
|
lineModuleVendorSN OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the vendor's serial number of the transceiver."
|
|
::= { lineModuleTableEntry 15 }
|
|
|
|
lineModuleDateCode OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the vendor's date code in the [yymmdd]-format."
|
|
::= { lineModuleTableEntry 16 }
|
|
|
|
lineModuleLaserCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the transmitter laser's bias current in milli ampere."
|
|
::= { lineModuleTableEntry 17 }
|
|
|
|
lineModuleTransmittedPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the transmitter optical output power in micro watt."
|
|
::= { lineModuleTableEntry 18 }
|
|
|
|
lineModuleReceivedPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the transmitter optical received power in micro watt."
|
|
::= { lineModuleTableEntry 19 }
|
|
|
|
lineModuleLaserTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the laser temperature in degree centigrade."
|
|
::= { lineModuleTableEntry 20 }
|
|
|
|
lineModuleVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the transceiver supply voltage in mV."
|
|
::= { lineModuleTableEntry 21 }
|
|
|
|
|
|
-- power supply table
|
|
|
|
powerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PowerList
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table describes the power-supply-status of the CWDM-system."
|
|
::= { eightChannelCwdm 5 }
|
|
|
|
powerTableEntry OBJECT-TYPE
|
|
SYNTAX PowerList
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry in the power-supply table."
|
|
INDEX
|
|
{ powerId } ::= { powerTable 1 }
|
|
|
|
PowerList ::= SEQUENCE {
|
|
powerId INTEGER,
|
|
powerArtNo DisplayString,
|
|
powerSerNo DisplayString,
|
|
powerDesc DisplayString,
|
|
powerTemperature INTEGER,
|
|
powerStatus INTEGER,
|
|
powerSuppliedPower INTEGER,
|
|
powerLoad INTEGER,
|
|
powerFanStatus INTEGER
|
|
}
|
|
|
|
powerId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the power-supply module id. "
|
|
::= { powerTableEntry 1 }
|
|
|
|
powerArtNo OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the article number of the power-supply module."
|
|
::= { powerTableEntry 2 }
|
|
|
|
powerSerNo OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the serial number of the power-supply module."
|
|
::= { powerTableEntry 3 }
|
|
|
|
powerDesc OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry provides a detailed description of the power-supply module."
|
|
::= { powerTableEntry 4 }
|
|
|
|
powerTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the temperature of the power-supply module."
|
|
::= { powerTableEntry 5 }
|
|
|
|
powerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255),
|
|
not-active (0),
|
|
active (1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the operational status of the power-supply module."
|
|
::= { powerTableEntry 6 }
|
|
|
|
powerSuppliedPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the power output of the power-supply module in watt."
|
|
::= { powerTableEntry 7 }
|
|
|
|
powerLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the load level of the power-supply module in percent."
|
|
::= { powerTableEntry 8 }
|
|
|
|
powerFanStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255),
|
|
not-active (0),
|
|
active (1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the fan status of the power-supply module."
|
|
::= { powerTableEntry 9 }
|
|
|
|
|
|
-- line interface table
|
|
|
|
lineIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LineIfList
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table describes the line-interface status of the CWDM-system."
|
|
::= { eightChannelCwdm 6 }
|
|
|
|
lineIfTableEntry OBJECT-TYPE
|
|
SYNTAX LineIfList
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry in the line-interface table."
|
|
INDEX
|
|
{ lineIfId } ::= { lineIfTable 1 }
|
|
|
|
LineIfList ::= SEQUENCE {
|
|
lineIfId INTEGER,
|
|
lineIfArtNo DisplayString,
|
|
lineIfSerNo DisplayString,
|
|
lineIfWestLinkStatus INTEGER,
|
|
lineIfEastLinkStatus INTEGER,
|
|
lineIfWestChannelStatus INTEGER,
|
|
lineIfEastChannelStatus INTEGER,
|
|
lineIfWestLinkRcvPower INTEGER,
|
|
lineIfEastLinkRcvPower INTEGER
|
|
}
|
|
|
|
lineIfId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the power-supply module id. "
|
|
::= { lineIfTableEntry 1 }
|
|
|
|
lineIfArtNo OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the article number of the power-supply module."
|
|
::= { lineIfTableEntry 2 }
|
|
|
|
lineIfSerNo OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the serial number of the power-supply module."
|
|
::= { lineIfTableEntry 3 }
|
|
|
|
lineIfWestLinkStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255),
|
|
off (0),
|
|
on (1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"This entry describes the west-link status of the interface module."
|
|
::= { lineIfTableEntry 4 }
|
|
|
|
lineIfEastLinkStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255),
|
|
off (0),
|
|
on (1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"This entry describes the east-link status of the interface module."
|
|
::= { lineIfTableEntry 5 }
|
|
|
|
lineIfWestChannelStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255),
|
|
not-in-use (0),
|
|
in-use (1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"This entry describes the west-channel status of the interface module."
|
|
::= { lineIfTableEntry 6 }
|
|
|
|
lineIfEastChannelStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255),
|
|
not-in-use (0),
|
|
in-use (1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"This entry describes the east-channel status of the interface module."
|
|
::= { lineIfTableEntry 7 }
|
|
|
|
lineIfWestLinkRcvPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"This entry describes the west-link receive power of the interface module in micro watts."
|
|
::= { lineIfTableEntry 8 }
|
|
|
|
lineIfEastLinkRcvPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (-255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"This entry describes the east-link receive power of the interface module in micro watts."
|
|
::= { lineIfTableEntry 9 }
|
|
|
|
|
|
-- passive optical module table
|
|
|
|
passiveTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PassiveList
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table describes the passive optical module status of the CWDM-system."
|
|
::= { eightChannelCwdm 7 }
|
|
|
|
passiveTableEntry OBJECT-TYPE
|
|
SYNTAX PassiveList
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry in the passive table."
|
|
INDEX
|
|
{ passiveId } ::= { passiveTable 1 }
|
|
|
|
PassiveList ::= SEQUENCE {
|
|
passiveId INTEGER,
|
|
passiveArtNo DisplayString,
|
|
passiveSerNo DisplayString
|
|
}
|
|
|
|
passiveId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the passive optical module id. "
|
|
::= { passiveTableEntry 1 }
|
|
|
|
passiveArtNo OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the article number of the power-supply module."
|
|
::= { passiveTableEntry 2 }
|
|
|
|
passiveSerNo OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the serial number of the power-supply module."
|
|
::= { passiveTableEntry 3 }
|
|
|
|
|
|
-- number of channel information :
|
|
|
|
channelCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry describes the number of channels in the CWDM-system."
|
|
::= { eightChannelCwdm 100 }
|
|
|
|
|
|
-- Trap Definitions :
|
|
|
|
minorAlarmRelayTrap TRAP-TYPE
|
|
ENTERPRISE eightChannelCwdm
|
|
VARIABLES { deviceMinorAlarm }
|
|
DESCRIPTION
|
|
"Trap indicating a change in the minor alarm relay status."
|
|
::= 0
|
|
|
|
majorAlarmRelayTrap TRAP-TYPE
|
|
ENTERPRISE eightChannelCwdm
|
|
VARIABLES { deviceMajorAlarm }
|
|
DESCRIPTION
|
|
"Trap indicating a change in the major alarm relay status."
|
|
::= 1
|
|
|
|
devicePowerSupplyTrap TRAP-TYPE
|
|
ENTERPRISE eightChannelCwdm
|
|
VARIABLES { powerId, powerStatus }
|
|
DESCRIPTION
|
|
"Trap indicating a change in the power-supply redundancy status."
|
|
::= 2
|
|
|
|
deviceTemperatureAlarmTrap TRAP-TYPE
|
|
ENTERPRISE eightChannelCwdm
|
|
VARIABLES { deviceTemperature,deviceTempAlarm }
|
|
DESCRIPTION
|
|
"Trap indicating a device temperature alarm event has occurred."
|
|
::= 3
|
|
|
|
deviceTemperatureShutdownTrap TRAP-TYPE
|
|
ENTERPRISE eightChannelCwdm
|
|
VARIABLES { deviceTemperature,deviceTempShutdown }
|
|
DESCRIPTION
|
|
"Trap indicating a device temperature shutdown event has occurred."
|
|
::= 4
|
|
|
|
fanAlarmTrap TRAP-TYPE
|
|
ENTERPRISE eightChannelCwdm
|
|
VARIABLES { powerId, powerFanStatus }
|
|
DESCRIPTION
|
|
"Trap indicating a fan alarm in a power supply module."
|
|
::= 5
|
|
|
|
portLocalLinkChangeTrap TRAP-TYPE
|
|
ENTERPRISE eightChannelCwdm
|
|
VARIABLES { portId, portLocalLink }
|
|
DESCRIPTION
|
|
"Trap indicating that a port's local link status has changed.
|
|
The port is identified by the portId variable."
|
|
::= 6
|
|
|
|
portLineLinkChangeTrap TRAP-TYPE
|
|
ENTERPRISE eightChannelCwdm
|
|
VARIABLES { portId, portLineLink }
|
|
DESCRIPTION
|
|
"Trap indicating that a port's line link status has changed.
|
|
The port is identified by the portId variable."
|
|
::= 7
|
|
|
|
END
|
|
|
|
|