-- Intel copyright information 2012/2013"
INTEL-SERVER-BASEBOARD7 DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, enterprises, Counter32, Integer32
FROM SNMPv2-SMI
DisplayString, TEXTUAL-CONVENTION
FROM SNMPv2-TC;
intel OBJECT IDENTIFIER ::= { enterprises 343 }
products OBJECT IDENTIFIER ::= { intel 2 }
server-management OBJECT IDENTIFIER ::= { products 10 }
software OBJECT IDENTIFIER ::= { server-management 3 }
baseboardGroup7 OBJECT IDENTIFIER ::= { software 5 }
systemManagementSoftwareGroup OBJECT IDENTIFIER ::= { baseboardGroup7 100 }
chassisInformationGroup OBJECT IDENTIFIER ::= { baseboardGroup7 200 }
processorGroup OBJECT IDENTIFIER ::= { baseboardGroup7 300 }
powerGroup OBJECT IDENTIFIER ::= { baseboardGroup7 400 }
memoryGroup OBJECT IDENTIFIER ::= { baseboardGroup7 500 }
thermalGroup OBJECT IDENTIFIER ::= { baseboardGroup7 600 }
driveSlotGroup OBJECT IDENTIFIER ::= { baseboardGroup7 700 }
miscellaneousGroup OBJECT IDENTIFIER ::= { baseboardGroup7 800 }
baseboard7EventGroup OBJECT IDENTIFIER ::= { baseboardGroup7 1000 }
--*****************************************************************************
--
-- MODULE IDENTITY AND REVISION GROUP
--
--*****************************************************************************
intelServerBaseboard7 MODULE-IDENTITY
LAST-UPDATED "201209151700Z" -- coordinated universal time UTC format is YYMMDDHHmmZ
ORGANIZATION "Intel, Server Management Software"
CONTACT-INFO " "
DESCRIPTION "This SNMP MIB module supports the Intel Server Baseboard SNMP subagent
for monitoring baseboard components, providing SNMP access to GET information
for baseboard components, SET sensor thresholds and support events through
the NOTIFICATION-TYPE construct.
Version: 2.0 9/15/2012
Intel copyright information 2012/2013"
::= { baseboardGroup7 1 }
IntelStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "The status used for the overall health of the server."
SYNTAX INTEGER {
unavailable(1),
healthy(2),
warning(3),
critical(4)}
IntelFeatureStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "The status of a particular feature."
SYNTAX INTEGER {
other(1),
unknown(2),
disabled(3),
enabled(4),
notImplemented(5) }
IntelRedundancyStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "The status of the redundancy capability if enabled on the server."
SYNTAX INTEGER {
other(1),
unknown(2),
full(3),
degraded(4),
lost(5),
notRedundant(6),
redundancyOffline(7),
notApplicable(8) }
OneBasedIndex ::= Integer32(1..2147483647)
--*****************************************************************************
--
-- SYSTEM MANAGEMENT SOFTWARE GROUP
--
--*****************************************************************************
systemManagementInfoOverallStatusHealth OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the overall health Status of the system."
::= { systemManagementSoftwareGroup 1 }
systemManagementInfoPlatformDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines an OEM configurable string to identify the
system. This value is set via the configuration file read during the SNMP agent
initialization."
::= { systemManagementSoftwareGroup 2 }
systemManagementInfoPlatformId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines an OEM configurable ID to identify the
system. This value is set via the configuration file read during the SNMP agent
initialization."
::= { systemManagementSoftwareGroup 3 }
systemManagementInfoTrapsEnabled OBJECT-TYPE
SYNTAX INTEGER {
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines whether or not TRAPs are enabled."
::= { systemManagementSoftwareGroup 4 }
systemManagementInfoSetsEnabled OBJECT-TYPE
SYNTAX INTEGER {
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines whether or not SETs are enabled."
::= { systemManagementSoftwareGroup 5 }
systemManagementManufacturerName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of the product manufacturer."
::= { systemManagementSoftwareGroup 6 }
systemManagementProductName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The display name of this software product."
::= { systemManagementSoftwareGroup 7 }
systemManagementProductVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The version of this software product."
::= { systemManagementSoftwareGroup 8 }
systemManagementProductBuildNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The build number of this software product."
::= { systemManagementSoftwareGroup 9 }
systemManagementProductDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of this software product."
::= { systemManagementSoftwareGroup 10 }
--*****************************************************************************
--
-- CHASIS INFORMATION GROUP
--
--*****************************************************************************
chassisStatus OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute maps the chassisSecurityState to the intelStatus value."
::= { chassisInformationGroup 1 }
chassisSecurityState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
ok(3),
breachdetected(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines whether the security is breached or not on the chassis."
::= { chassisInformationGroup 2 }
chassisBootState OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the boot state of the system."
::= { chassisInformationGroup 3 }
chassisThermalState OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the thermal state of the chassis."
::= { chassisInformationGroup 4 }
chassisPowerState OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the thermal state of the chassis."
::= { chassisInformationGroup 5 }
chassisLockState OBJECT-TYPE
SYNTAX INTEGER {
notpresent(1),
present(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines whether a lock is present on the chassis."
::= { chassisInformationGroup 6 }
chassisKeyboardPasswordStatus OBJECT-TYPE
SYNTAX IntelFeatureStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the keyboard password status."
::= { chassisInformationGroup 7 }
chassisPowerOnPasswordStatus OBJECT-TYPE
SYNTAX IntelFeatureStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the power on password status."
::= { chassisInformationGroup 8 }
chassisAdministratorPasswordStatus OBJECT-TYPE
SYNTAX IntelFeatureStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the administrator password status."
::= { chassisInformationGroup 9 }
chassisFrontPanelResetStatus OBJECT-TYPE
SYNTAX IntelFeatureStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the front panel reset status."
::= { chassisInformationGroup 10 }
chassisContainerType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
desktop(3),
lowProfileDesktop(4),
pizzaBox(5),
miniTower(6),
tower(7),
portable(8),
laptop(9),
notebook(10),
handHeld(11),
dockingStation(12),
allInOne(13),
subNoteBook(14),
spaceSaving(15),
lunchBox(16),
mainSystemChassis(17),
expansionChassis(18),
subChassis(19),
busExpansionChassis(20),
peripheralChassis(21),
raidChassis(22),
rackMountChassis(23),
sealedCasePC(24),
multiSystemChassis(25)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the container type of the chassis."
::= { chassisInformationGroup 11 }
chassisPartNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute provides the part number of the system."
::= { chassisInformationGroup 12 }
chassisSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute provides the serial number of the system."
::= { chassisInformationGroup 13 }
chassisName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute provides the name of the system."
::= { chassisInformationGroup 14 }
chassisAssetTag OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute of asset tag for the system."
::= { chassisInformationGroup 15 }
--*****************************************************************************
--
-- Processor Group
--
--*****************************************************************************
-------------------------------------------------------------------------------
-- Processor Device Table
-------------------------------------------------------------------------------
processorDeviceTable OBJECT-TYPE
SYNTAX SEQUENCE OF ProcessorDeviceTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This Group defines the Processor Device Table."
::= { processorGroup 10 }
processorDeviceTableEntry OBJECT-TYPE
SYNTAX ProcessorDeviceTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This Group defines the Processor Device Table Entry."
INDEX { processorIndex }
::= { processorDeviceTable 1 }
ProcessorDeviceTableEntry ::= SEQUENCE {
processorIndex OneBasedIndex,
processorCIMDeviceId INTEGER,
processorDescription DisplayString,
processorStatusString DisplayString,
processorStatus IntelStatus,
processorType INTEGER,
processorPartNumber DisplayString,
processorManufacturerName DisplayString,
processorFamily INTEGER,
processorVersionName DisplayString,
processorMaxSpeed INTEGER,
processorCurrentSpeed INTEGER,
processorExternalClockSpeed INTEGER,
processorVoltage INTEGER,
processorUpgradeMethod INTEGER,
processorSocketDesignation DisplayString,
processorID DisplayString
}
processorIndex OBJECT-TYPE
SYNTAX OneBasedIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the index of the Processor Device in the chassis."
::= { processorDeviceTableEntry 1 }
processorCIMDeviceId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the DeviceId used by the Intel CIM software to uniquely
identify the device. For processors it will be the sensor #."
::= { processorDeviceTableEntry 2 }
processorDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the status of the processor."
::= { processorDeviceTableEntry 3 }
processorStatusString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the status of the processor."
::= { processorDeviceTableEntry 4 }
processorStatus OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the health value for the processor."
::= { processorDeviceTableEntry 5 }
processorType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
centralProcessor(3),
mathProcessor(4),
dspProcessor(5),
videoProcessor(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the type of the Processor according
to the SMBIOS definitions."
::= { processorDeviceTableEntry 6 }
processorPartNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the part number of the Processor Device."
::= { processorDeviceTableEntry 7 }
processorManufacturerName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the name of manufacturer of the Processor Device."
::= { processorDeviceTableEntry 8 }
processorFamily OBJECT-TYPE
SYNTAX INTEGER {
vOther (1),
vUnknown (2),
v8086 (3),
v80286 (4),
v80386 (5),
v80486 (6),
v8087 (7),
v80287 (8),
v80387 (9),
v80487 (10),
vPentiumProcessor (11),
vPentiumProProcessor (12),
vPentiumIIProcessor (13),
vPentiumProcessorWithMMXTechnology (14),
vCeleronProcessor (15),
vPentiumIIXeonProcessor (16),
vPentiumIIIProcessor (17),
vM1Family (18),
vM2Family (19),
vK5Family (25),
vK6Family (26),
vPowerPcFamily (32),
vPowerPc601 (33),
vPowerPc603 (34),
vPowerPc603p (35),
vPowerPc604 (36),
vAlphaFamily (48),
vMipsFamily (64),
vSparcFamily (80),
v68040 (96),
v68xxxFamily (97),
v68000 (98),
v68010 (99),
v68020 (100),
v68030 (101),
vHobbitFamily (112),
vWeitek (128),
vItaniumProcessor (130),
vPa-riscFamily (144),
vV30Family (160),
vPentiumIIIXeonProcessor (176),
vPentiumIIIProcessorwithSpeedStepTechnology (177),
vPentium4Processor (178),
vIntelXeon (179),
vIntelXeonprocessorMP (181),
vIntelItanium2Processor (184)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the family of the Processor Device."
::= { processorDeviceTableEntry 9 }
processorVersionName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the name of the version of the Processor Device."
::= { processorDeviceTableEntry 10 }
processorMaxSpeed OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the current speed of the Processor
Device in MHz."
::= { processorDeviceTableEntry 11 }
processorCurrentSpeed OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the current speed of the Processor
Device in MHz."
::= { processorDeviceTableEntry 12 }
processorExternalClockSpeed OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the speed of the external clock for
the Processor Device in MHz."
::= { processorDeviceTableEntry 13 }
processorVoltage OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the voltage powering the Processor
Device in millivolts."
::= { processorDeviceTableEntry 14 }
processorUpgradeMethod OBJECT-TYPE
SYNTAX INTEGER {
vOther (1),
vUnknown (2),
vDaughterBoard (3),
vZifSocket (4),
vReplacementpiggyBack (5),
vNone (6),
vLIFSocket (7),
vSlot1 (8),
vSlot2 (9),
v370pinSocket (10),
vSlotA (11),
vSlotM (12),
vSocket423 (13),
vSocketASocket462 (14),
vSocket478 (15),
vSocket754 (16),
vSocket940 (17),
vSocket939 (18),
vSocketmPGA604 (19),
vSocketLGA771 (20),
vSocketLGA775 (21),
vSocketS1 (22),
vSocketAM2 (23),
vSocketF(1207) (24),
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the processor upgrade method for the
Processor Device."
::= { processorDeviceTableEntry 15 }
processorSocketDesignation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the string number for reference designation. "
::= { processorDeviceTableEntry 16 }
processorID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute corresponds to the Processor ID field from the
SMBIOS specification. This attribute contains processor specific information
that describes the processor's features. "
::= { processorDeviceTableEntry 17 }
-------------------------------------------------------------------------------
-- Discrete Processor Sensor Table
-------------------------------------------------------------------------------
discreteProcessorTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiscreteProcessorTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Discrete Processor Sensor Table."
::= { processorGroup 20 }
discreteProcessorTableEntry OBJECT-TYPE
SYNTAX DiscreteProcessorTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Discrete Processor Sensor Table Entry."
INDEX { discreteProcessorIndex }
::= { discreteProcessorTable 1 }
DiscreteProcessorTableEntry ::= SEQUENCE {
discreteProcessorIndex OneBasedIndex,
discreteProcessorCIMDeviceId INTEGER,
discreteProcessorDescription DisplayString,
discreteProcessorStatusString DisplayString,
discreteProcessorStatus IntelStatus
}
discreteProcessorIndex OBJECT-TYPE
SYNTAX OneBasedIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the index (one based) of the discrete processor sensor."
::= { discreteProcessorTableEntry 1 }
discreteProcessorCIMDeviceId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the DeviceId used by the Intel CIM software
to uniquely identify the device, it represents the [channel#][sensor#][IPMB OwnerID][LUN]."
::= { discreteProcessorTableEntry 2 }
discreteProcessorDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute textually describes the discrete processor sensor."
::= { discreteProcessorTableEntry 3 }
discreteProcessorStatusString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current status of the discrete processor sensor will be one of the
following strings: ok, critical, or unknown."
::= { discreteProcessorTableEntry 4 }
discreteProcessorStatus OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current health status of the discrete processor sensor."
::= { discreteProcessorTableEntry 5 }
--*****************************************************************************
--
-- POWER GROUP
--
--*****************************************************************************
-------------------------------------------------------------------------------
-- Power Unit Table
-------------------------------------------------------------------------------
powerUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF PowerUnitTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Power Unit Table. If power redundancy
is enabled on the server, there will be a single entry in the table coresponding
to the single sensor for redundancy implemented in the BMC. If power redundancy
is not implemented on the server, then there will be no entries in the powerUnitTable."
::= { powerGroup 10 }
powerUnitTableEntry OBJECT-TYPE
SYNTAX PowerUnitTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Power Unit Table Entry."
INDEX { powerUnitIndex }
::= { powerUnitTable 1 }
PowerUnitTableEntry ::= SEQUENCE {
powerUnitIndex OneBasedIndex,
powerUnitCIMDeviceId INTEGER,
powerUnitDescription DisplayString,
powerUnitStatusString DisplayString,
powerUnitStatus IntelStatus,
powerUnitRedundancyStatus IntelRedundancyStatus
}
powerUnitIndex OBJECT-TYPE
SYNTAX OneBasedIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the index (one based) of the power unit."
::= { powerUnitTableEntry 1 }
powerUnitCIMDeviceId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the DeviceId used by the Intel CIM software
to uniquely identify the device, it represents the [channel#][sensor#][IPMB OwnerID][LUN]."
::= { powerUnitTableEntry 2 }
powerUnitDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute provides the description of the power unit."
::= { powerUnitTableEntry 3 }
powerUnitStatusString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current status of the sensor will be one of the
following strings: other, unknown, ok, nonCritical, critical, nonRecoverable."
::= { powerUnitTableEntry 4 }
powerUnitStatus OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current health status of the sensor."
::= { powerUnitTableEntry 5 }
powerUnitRedundancyStatus OBJECT-TYPE
SYNTAX IntelRedundancyStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the redundancy status of the power unit."
::= { powerUnitTableEntry 6 }
-------------------------------------------------------------------------------
-- Power Supply Table
-------------------------------------------------------------------------------
powerSupplyTable OBJECT-TYPE
SYNTAX SEQUENCE OF PowerSupplyTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Power Supply Table."
::= { powerGroup 20 }
powerSupplyTableEntry OBJECT-TYPE
SYNTAX PowerSupplyTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Power Supply Table Entry."
INDEX { powerSupplyIndex }
::= { powerSupplyTable 1 }
PowerSupplyTableEntry ::= SEQUENCE {
powerSupplyIndex OneBasedIndex,
powerSupplyCIMDeviceId INTEGER,
powerSupplyDescription DisplayString,
powerSupplyStatusString DisplayString,
powerSupplyStatus IntelStatus
}
powerSupplyIndex OBJECT-TYPE
SYNTAX OneBasedIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the index (one based) of the power supply."
::= { powerSupplyTableEntry 1 }
powerSupplyCIMDeviceId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the DeviceId used by the Intel CIM software
to uniquely identify the device, it represents the [channel#][sensor#][IPMB OwnerID][LUN]."
::= { powerSupplyTableEntry 2 }
powerSupplyDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute textually describes the power supply."
::= { powerSupplyTableEntry 3 }
powerSupplyStatusString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current status of the sensor will be one of the
following strings: other, unknown, ok, nonCritical, critical, nonRecoverable."
::= { powerSupplyTableEntry 4 }
powerSupplyStatus OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current health status of the sensor."
::= { powerSupplyTableEntry 5 }
-------------------------------------------------------------------------------
-- Voltage Probe Table
-------------------------------------------------------------------------------
voltageProbeTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoltageProbeTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Voltage Probe Table."
::= { powerGroup 30 }
voltageProbeTableEntry OBJECT-TYPE
SYNTAX VoltageProbeTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Voltage Probe Table Entry."
INDEX { voltageIndex }
::= { voltageProbeTable 1 }
VoltageProbeTableEntry ::= SEQUENCE {
voltageIndex OneBasedIndex,
voltageCIMDeviceId INTEGER,
voltageDescription DisplayString,
voltageStatusString DisplayString,
voltageStatus IntelStatus,
voltageReading INTEGER,
voltageUpperNonRecoverableThreshold INTEGER,
voltageUpperCriticalThreshold INTEGER,
voltageUpperNonCriticalThreshold INTEGER,
voltageLowerNonCriticalThreshold INTEGER,
voltageLowerCriticalThreshold INTEGER,
voltageLowerNonRecoverableThreshold INTEGER,
voltageResolution INTEGER,
voltageTolerance INTEGER,
voltageAccuracy INTEGER
}
voltageIndex OBJECT-TYPE
SYNTAX OneBasedIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the index (one based) of the voltage probe."
::= { voltageProbeTableEntry 1 }
voltageCIMDeviceId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the DeviceId used by the Intel CIM software
to uniquely identify the device, it represents the [channel#][sensor#][IPMB OwnerID][LUN]."
::= { voltageProbeTableEntry 2 }
voltageDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute textually describes the voltage probe."
::= { voltageProbeTableEntry 3}
voltageStatusString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current status of the sensor will be one of the
following strings: other, unknown, ok, nonCritical, critical, nonRecoverable."
::= { voltageProbeTableEntry 4}
voltageStatus OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current health status of the sensor."
::= { voltageProbeTableEntry 5 }
voltageReading OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current reading of the voltage probe in millivolts."
::= { voltageProbeTableEntry 6 }
voltageUpperNonRecoverableThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The upper non-recoverable threshold for the voltage probe,in
millivolts. 0x7fffffff (2147483647) denotes 'unknown'."
::= { voltageProbeTableEntry 7 }
voltageUpperCriticalThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The upper critical threshold for the voltage probe, in
millivolts. 0x7fffffff (2147483647) denotes 'unknown'."
::= { voltageProbeTableEntry 8 }
voltageUpperNonCriticalThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The upper non-critical threshold for the voltage probe, in
millivolts. 0x7fffffff (2147483647) denotes 'unknown'."
::= { voltageProbeTableEntry 9 }
voltageLowerNonCriticalThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The lower non-critical threshold for the voltage probe, in
millivolts. 0x7fffffff (2147483647) denotes 'unknown'."
::= { voltageProbeTableEntry 10 }
voltageLowerCriticalThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The lower non-critical threshold for the voltage probe, in
millivolts. 0x7fffffff (2147483647) denotes 'unknown'."
::= { voltageProbeTableEntry 11 }
voltageLowerNonRecoverableThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The lower non-recoverable threshold for the voltage probe, in
millivolts. 0x7fffffff (2147483647) denotes 'unknown'."
::= { voltageProbeTableEntry 12 }
voltageResolution OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The resolution for the reading from this voltage probe, in
tenths of millivolts. '0x7fffffff (2147483647) denotes 'unknown'."
::= { voltageProbeTableEntry 13 }
voltageTolerance OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The tolerance for the reading from this voltage probe, in
plus/minusmillivolts. 0x7fffffff (2147483647) denotes 'unknown'."
::= { voltageProbeTableEntry 14 }
voltageAccuracy OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The accuracy for the reading from this voltage probe, in
plus/minus hundredths of a percent. 0x7fffffff (2147483647) denotes 'unknown'."
::= { voltageProbeTableEntry 15 }
-------------------------------------------------------------------------------
-- Discrete Voltage Probe Table
-------------------------------------------------------------------------------
discreteVoltageProbeTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiscreteVoltageProbeTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Discrete Voltage Probe Table."
::= { powerGroup 40 }
discreteVoltageProbeTableEntry OBJECT-TYPE
SYNTAX DiscreteVoltageProbeTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Discrete Voltage Probe Table Entry."
INDEX { discreteVoltageIndex }
::= { discreteVoltageProbeTable 1 }
DiscreteVoltageProbeTableEntry ::= SEQUENCE {
discreteVoltageIndex OneBasedIndex,
discreteVoltageCIMDeviceId INTEGER,
discreteVoltageDescription DisplayString,
discreteVoltageStatusString DisplayString,
discreteVoltageStatus IntelStatus,
discreteVoltagePerformance INTEGER
}
discreteVoltageIndex OBJECT-TYPE
SYNTAX OneBasedIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the index (one based) of the voltage probe."
::= { discreteVoltageProbeTableEntry 1 }
discreteVoltageCIMDeviceId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the DeviceId used by the Intel CIM software
to uniquely identify the device, it represents the [channel#][sensor#][IPMB OwnerID][LUN]."
::= { discreteVoltageProbeTableEntry 2 }
discreteVoltageDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute textually describes the discrete voltage probe."
::= { discreteVoltageProbeTableEntry 3 }
discreteVoltageStatusString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current status of the sensor will be one of the
following strings: other, unknown, ok, nonCritical, critical, nonRecoverable."
::= { discreteVoltageProbeTableEntry 4 }
discreteVoltageStatus OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current health status of the sensor."
::= { discreteVoltageProbeTableEntry 5 }
discreteVoltagePerformance OBJECT-TYPE
SYNTAX INTEGER {
met(1),
lags(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Describes whether or not the discrete voltage probe meets performance
standards, or is lagging."
::= { discreteVoltageProbeTableEntry 6 }
-------------------------------------------------------------------------------
-- Current Probe Table
-------------------------------------------------------------------------------
currentProbeTable OBJECT-TYPE
SYNTAX SEQUENCE OF CurrentProbeTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Voltage Probe Table."
::= { powerGroup 50 }
currentProbeTableEntry OBJECT-TYPE
SYNTAX CurrentProbeTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Voltage Probe Table Entry."
INDEX { currentIndex }
::= { currentProbeTable 1 }
CurrentProbeTableEntry ::= SEQUENCE {
currentIndex OneBasedIndex,
currentCIMDeviceId INTEGER,
currentDescription DisplayString,
currentStatusString DisplayString,
currentStatus IntelStatus,
currentReading INTEGER,
currentUpperNonRecoverableThreshold INTEGER,
currentUpperCriticalThreshold INTEGER,
currentUpperNonCriticalThreshold INTEGER,
currentLowerNonCriticalThreshold INTEGER,
currentLowerCriticalThreshold INTEGER,
currentLowerNonRecoverableThreshold INTEGER,
currentResolution INTEGER,
currentTolerance INTEGER,
currentAccuracy INTEGER
}
currentIndex OBJECT-TYPE
SYNTAX OneBasedIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the index (one based) of the current probe."
::= { currentProbeTableEntry 1 }
currentCIMDeviceId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the DeviceId used by the Intel CIM software
to uniquely identify the device, it represents the [channel#][sensor#][IPMB OwnerID][LUN]."
::= { currentProbeTableEntry 2 }
currentDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute textually describes the current probe."
::= { currentProbeTableEntry 3}
currentStatusString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current status of the sensor will be one of the
following strings: other, unknown, ok, nonCritical, critical, nonRecoverable."
::= { currentProbeTableEntry 4}
currentStatus OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current health status of the sensor."
::= { currentProbeTableEntry 5 }
currentReading OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current reading of the current probe in millivolts."
::= { currentProbeTableEntry 6 }
currentUpperNonRecoverableThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The upper non-recoverable threshold for the current probe,in
millivolts. 0x7fffffff (2147483647) denotes 'unknown'."
::= { currentProbeTableEntry 7 }
currentUpperCriticalThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The upper critical threshold for the current probe, in
millivolts. 0x7fffffff (2147483647) denotes 'unknown'."
::= { currentProbeTableEntry 8 }
currentUpperNonCriticalThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The upper non-critical threshold for the current probe, in
millivolts. 0x7fffffff (2147483647) denotes 'unknown'."
::= { currentProbeTableEntry 9 }
currentLowerNonCriticalThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The lower non-critical threshold for the current probe, in
millivolts. 0x7fffffff (2147483647) denotes 'unknown'."
::= { currentProbeTableEntry 10 }
currentLowerCriticalThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The lower non-critical threshold for the current probe, in
millivolts. 0x7fffffff (2147483647) denotes 'unknown'."
::= { currentProbeTableEntry 11 }
currentLowerNonRecoverableThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The lower non-recoverable threshold for the current probe, in
millivolts. 0x7fffffff (2147483647) denotes 'unknown'."
::= { currentProbeTableEntry 12 }
currentResolution OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The resolution for the reading from this current probe, in
tenths of millivolts. '0x7fffffff (2147483647) denotes 'unknown'."
::= { currentProbeTableEntry 13 }
currentTolerance OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The tolerance for the reading from this current probe, in
plus/minusmillivolts. 0x7fffffff (2147483647) denotes 'unknown'."
::= { currentProbeTableEntry 14 }
currentAccuracy OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The accuracy for the reading from this current probe, in
plus/minus hundredths of a percent. 0x7fffffff (2147483647) denotes 'unknown'."
::= { currentProbeTableEntry 15 }
--*****************************************************************************
--
-- MEMORY GROUP
--
-- CURRENTLY UNDER CONSTRUCTION. This group requires data definition by
-- SMBIOS interface to be completed.
--
--*****************************************************************************
-------------------------------------------------------------------------------
-- Physical Memory Array Table
-------------------------------------------------------------------------------
physicalMemoryArrayTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhysicalMemoryArrayTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This Group defines the Physical Memory Array Table."
::= { memoryGroup 10 }
physicalMemoryArrayTableEntry OBJECT-TYPE
SYNTAX PhysicalMemoryArrayTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This Group defines the Physical Memory Array Table Entry."
INDEX { physicalMemoryArrayIndex }
::= { physicalMemoryArrayTable 1 }
PhysicalMemoryArrayTableEntry ::= SEQUENCE {
physicalMemoryArrayIndex OneBasedIndex,
physicalMemoryArrayCIMDeviceId INTEGER,
physicalMemoryArrayDescription DisplayString,
physicalMemoryArrayStatusString DisplayString,
physicalMemoryArrayStatus IntelStatus,
physicalMemoryArrayLocation INTEGER,
physicalMemoryArrayMaxCapacity INTEGER,
physicalMemoryArrayNumberOfDevices INTEGER,
physicalMemoryArrayErrorCorrection INTEGER,
physicalMemoryArrayHandle INTEGER,
physicalMemoryArrayUsageCode INTEGER,
physicalMemoryArrayTag DisplayString,
physicalMemoryArrayUsedSlot INTEGER
}
physicalMemoryArrayIndex OBJECT-TYPE
SYNTAX OneBasedIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the index of the Physical Memory Array in this chassis."
::= { physicalMemoryArrayTableEntry 1 }
physicalMemoryArrayCIMDeviceId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the DeviceId used by the Intel CIM software
to uniquely identify the device."
::= { physicalMemoryArrayTableEntry 2 }
physicalMemoryArrayDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines a textual description of the Physical Memory Array."
::= { physicalMemoryArrayTableEntry 3 }
physicalMemoryArrayStatusString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current status of the sensor will be one of the
following strings: other, unknown, ok, nonCritical, critical, nonRecoverable."
::= { physicalMemoryArrayTableEntry 4 }
physicalMemoryArrayStatus OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current health status of the sensor."
::= { physicalMemoryArrayTableEntry 5 }
physicalMemoryArrayLocation OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the of the Physical Memory Array."
::= { physicalMemoryArrayTableEntry 6 }
physicalMemoryArrayMaxCapacity OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the maximum capacity of the Physical Memory Array."
::= { physicalMemoryArrayTableEntry 7 }
physicalMemoryArrayNumberOfDevices OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the number of slots available for memory devices
in this array."
::= { physicalMemoryArrayTableEntry 8 }
physicalMemoryArrayErrorCorrection OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
none(3),
singleBitErrorCorrecting(4),
doubleBitErrorCorrecting(5),
errorScrubbing(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the error correction of the Physical Memory Array."
::= { physicalMemoryArrayTableEntry 9 }
physicalMemoryArrayHandle OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute is the handle, or instance number, associated with any error
that was previously detected for the array."
::= { physicalMemoryArrayTableEntry 10 }
physicalMemoryArrayUsageCode OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
systemMemory(3),
videoMemory(4),
flashMemory(5),
nonVolatileRAM(6),
cacheMemory(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute describes the usage for the memory array."
::= { physicalMemoryArrayTableEntry 11 }
physicalMemoryArrayTag OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute provides a textual description of the array, and
includes the handle integer in the description."
::= { physicalMemoryArrayTableEntry 12 }
physicalMemoryArrayUsedSlot OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute is the count of used slots."
::= { physicalMemoryArrayTableEntry 13 }
-------------------------------------------------------------------------------
-- Physical Memory Device Table
-------------------------------------------------------------------------------
physicalMemoryDeviceTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhysicalMemoryDeviceTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This Group defines the Physical Memory Device Table."
::= { memoryGroup 20 }
physicalMemoryDeviceTableEntry OBJECT-TYPE
SYNTAX PhysicalMemoryDeviceTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This Group defines the Physical Memory Device Table Entry."
INDEX { physicalMemoryDeviceIndex }
::= { physicalMemoryDeviceTable 1 }
PhysicalMemoryDeviceTableEntry ::= SEQUENCE {
physicalMemoryDeviceIndex OneBasedIndex,
physicalMemoryDeviceCIMDeviceId INTEGER,
physicalMemoryDeviceDescription DisplayString,
physicalMemoryDeviceStatusString DisplayString,
physicalMemoryDeviceStatus IntelStatus,
physicalMemoryDeviceTag DisplayString,
physicalMemoryDeviceHandle INTEGER,
physicalMemoryDeviceAssociatedArray INTEGER,
physicalMemoryDeviceTotalWidth INTEGER,
physicalMemoryDeviceDataWidth INTEGER,
physicalMemoryDeviceSize INTEGER,
physicalMemoryDeviceFormFactor INTEGER,
physicalMemoryDeviceLocator DisplayString,
physicalMemoryDeviceBankLabel DisplayString,
physicalMemoryDeviceMemoryType INTEGER,
physicalMemoryDeviceTypeDetail INTEGER,
physicalMemoryDeviceSpeed INTEGER,
physicalMemoryDeviceManufacturer DisplayString,
physicalMemoryDeviceSerialNumber DisplayString,
physicalMemoryDeviceAssetTag DisplayString,
physicalMemoryDevicePartNumber DisplayString
}
physicalMemoryDeviceIndex OBJECT-TYPE
SYNTAX OneBasedIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the index of the Physical Memory Device in this chassis."
::= { physicalMemoryDeviceTableEntry 1 }
physicalMemoryDeviceCIMDeviceId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the DeviceId used by the Intel CIM software
to uniquely identify the device."
::= { physicalMemoryDeviceTableEntry 2 }
physicalMemoryDeviceDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines a textual description of the Physical Memory Array."
::= { physicalMemoryDeviceTableEntry 3 }
physicalMemoryDeviceStatusString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current status of the sensor will be one of the
following strings: other, unknown, ok, nonCritical, critical, nonRecoverable."
::= { physicalMemoryDeviceTableEntry 4 }
physicalMemoryDeviceStatus OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current health status of the sensor."
::= { physicalMemoryDeviceTableEntry 5 }
physicalMemoryDeviceTag OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines a textual description of the Physical Memory Device."
::= { physicalMemoryDeviceTableEntry 6 }
physicalMemoryDeviceHandle OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines a textual description of the Physical Memory Device."
::= { physicalMemoryDeviceTableEntry 7 }
physicalMemoryDeviceAssociatedArray OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the associated array of the Physical Memory Device."
::= { physicalMemoryDeviceTableEntry 8 }
physicalMemoryDeviceTotalWidth OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the total width in bits of the Physical Memory Device,
including any check or error correction bits. If there are no error correction bits, this
value should be equal to data width. If the width is unknown, the field is set to FFFFh."
::= { physicalMemoryDeviceTableEntry 9 }
physicalMemoryDeviceDataWidth OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the width in bits of the Physical Memory Device.
A data width of 0 and a total width of 8 indicates that the device is being used
solely to provide 8 error correction bits. If the width is unknown, the field
is set to FFFFh."
::= { physicalMemoryDeviceTableEntry 10 }
physicalMemoryDeviceSize OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the size of the memory device in MB. If the value
is 0, no memory device is installed in the socket. if the size is unknown, the field
value is FFFFh. The granularity in which the value is specified depends on the setting
of the most significant bit, bit 15. If the bit is 0, the value is specified in megabyte
units; if the bit is 1, the value is specified in kilobyte units. For example, the value
8100h identifies a 256KM memory device and 0100h identifies a 256MB memory device."
::= { physicalMemoryDeviceTableEntry 11 }
physicalMemoryDeviceFormFactor OBJECT-TYPE
SYNTAX INTEGER {
vOther (1),
vUnknown (2),
vSIMM (3),
vSIP (4),
vChip (5),
vDIP (6),
vZIP (7),
vProprietaryCard (8),
vDIMM (9),
vTSOP (10),
vRowOfChips (11),
vRIMM (12),
vSODIMM (13),
vSRIMM (14),
vFBDIMM (15)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the form factor of the Physical Memory Device."
::= { physicalMemoryDeviceTableEntry 12 }
physicalMemoryDeviceLocator OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string that identifies the physically labeled socket or board
position where the memory device is located."
::= { physicalMemoryDeviceTableEntry 13 }
physicalMemoryDeviceBankLabel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string that identifies the physically labeled bank where the
memory device is located."
::= { physicalMemoryDeviceTableEntry 14 }
physicalMemoryDeviceMemoryType OBJECT-TYPE
SYNTAX INTEGER {
vOther (1),
vUnknown (2),
vDRAM (3),
vEDRAM (4),
vVRAM (5),
vSRAM (6),
vRAM (7),
vROM (8),
vFLASH (9),
vEEPROM (10),
vFEPROM (11),
vEPROM (12),
vCDRAM (13),
v3DRAM (14),
vSDRAM (15),
vSGRAM (16),
vRDRAM (17),
vDDR (18),
vDDR2 (19),
vFBDIMM (20),
vDDR3 (21),
vDDR4 (22)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the type of the Physical Memory Device as per
the SMBIOS 2.3.4 specification."
::= { physicalMemoryDeviceTableEntry 15 }
physicalMemoryDeviceTypeDetail OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute is bit encoded and specifies additional detail
about the physical Memory Device. SMBIOS 2.3.4 specification defines that
multiple bits can be set if more then one of the following attributes applies:
bit 0 reserved, set to 0 bit 7 synchronous
bit 1 other bit 8 CMOS
bit 2 unknown bit 9 EDO
bit 3 fast-paged bit 10 Window DRAM
bit 4 static column bit 11 cache DRAM
bit 5 pseudo-static bit 12 non-volatile
bit 6 RAMBUS bits 13:15 reserves, set to 0"
::= { physicalMemoryDeviceTableEntry 16 }
physicalMemoryDeviceSpeed OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The speed of the device in MHz, or 0 if unknown."
::= { physicalMemoryDeviceTableEntry 17 }
physicalMemoryDeviceManufacturer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string number for the manufacturer of this device."
::= { physicalMemoryDeviceTableEntry 18 }
physicalMemoryDeviceSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string number for the serial number of this memory device."
::= { physicalMemoryDeviceTableEntry 19 }
physicalMemoryDeviceAssetTag OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string number for the asset tag of this memory device."
::= { physicalMemoryDeviceTableEntry 20 }
physicalMemoryDevicePartNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string part number if this memory device."
::= { physicalMemoryDeviceTableEntry 21 }
-------------------------------------------------------------------------------
-- Discrete Memory Sensor Table
-------------------------------------------------------------------------------
discreteMemoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiscreteMemoryTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Discrete Memory Sensor Table."
::= { memoryGroup 30 }
discreteMemoryTableEntry OBJECT-TYPE
SYNTAX DiscreteMemoryTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Discrete Memory Sensor Table Entry."
INDEX { discreteMemoryIndex }
::= { discreteMemoryTable 1 }
DiscreteMemoryTableEntry ::= SEQUENCE {
discreteMemoryIndex OneBasedIndex,
discreteMemoryCIMDeviceId INTEGER,
discreteMemoryDescription DisplayString,
discreteMemoryStatusString DisplayString,
discreteMemoryStatus IntelStatus
}
discreteMemoryIndex OBJECT-TYPE
SYNTAX OneBasedIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the index (one based) of the discrete memory sensor."
::= { discreteMemoryTableEntry 1 }
discreteMemoryCIMDeviceId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the DeviceId used by the Intel CIM software
to uniquely identify the device, it represents the [channel#][sensor#][IPMB OwnerID][LUN]."
::= { discreteMemoryTableEntry 2 }
discreteMemoryDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute textually describes the discrete memory sensor."
::= { discreteMemoryTableEntry 3 }
discreteMemoryStatusString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current status of the discrete memory sensor will be one of the
following strings: ok, critical, or unknown."
::= { discreteMemoryTableEntry 4 }
discreteMemoryStatus OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current health status of the discrete memory sensor."
::= { discreteMemoryTableEntry 5 }
--*****************************************************************************
--
-- THERMAL GROUP
--
--*****************************************************************************
-------------------------------------------------------------------------------
-- Cooling Unit Table
-------------------------------------------------------------------------------
coolingUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF CoolingUnitTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Cooling Unit Table. If cooling redundancy
is enabled on the server, there will be a single entry in the table coresponding
to the single sensor for redundancy implemented in the BMC. If cooling redundancy
is not implemented on the server, then there will be no entries in the coolingUnitTable."
::= { thermalGroup 10 }
coolingUnitTableEntry OBJECT-TYPE
SYNTAX CoolingUnitTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Cooling Unit Table Entry."
INDEX { coolingUnitIndex }
::= { coolingUnitTable 1 }
CoolingUnitTableEntry ::= SEQUENCE {
coolingUnitIndex OneBasedIndex,
coolingUnitCIMDeviceId INTEGER,
coolingUnitDescription DisplayString,
coolingUnitStatusString DisplayString,
coolingUnitStatus IntelStatus,
coolingUnitRedundancyStatus IntelRedundancyStatus,
coolingUnitCaption DisplayString
}
coolingUnitIndex OBJECT-TYPE
SYNTAX OneBasedIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the index (one based) of the cooling unit."
::= { coolingUnitTableEntry 1}
coolingUnitCIMDeviceId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the DeviceId used by the Intel CIM software
to uniquely identify the device, it represents the [channel#][sensor#][IPMB OwnerID][LUN]."
::= { coolingUnitTableEntry 2 }
coolingUnitDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute textually describes the cooling unit."
::= { coolingUnitTableEntry 3 }
coolingUnitStatusString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current status of the sensor will be one of the
following strings: other, unknown, ok, nonCritical, critical, nonRecoverable."
::= { coolingUnitTableEntry 4 }
coolingUnitStatus OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current health status of the sensor."
::= { coolingUnitTableEntry 5 }
coolingUnitRedundancyStatus OBJECT-TYPE
SYNTAX IntelRedundancyStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Gives the redundancy status of the Cooling Unit. 'Fully Redundan
' means that all of the configured redundancy is still available; 'Degraded
Redundancy' means that some failures have been experienced but some reduced
amount of redundancy is still available; 'Redundancy Lost' means that a sufficie
t number of failures have been experienced that no redundancy is available
and the next failure experienced within the Cooling Unit will cause overall
Cooling Unit failure. "
::= { coolingUnitTableEntry 6 }
coolingUnitCaption OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute provides the caption for the cooling unit."
::= { coolingUnitTableEntry 7 }
-------------------------------------------------------------------------------
-- Cooling Device Table
-------------------------------------------------------------------------------
coolingDeviceTable OBJECT-TYPE
SYNTAX SEQUENCE OF CoolingDeviceTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Cooling Device Table."
::= { thermalGroup 20 }
coolingDeviceTableEntry OBJECT-TYPE
SYNTAX CoolingDeviceTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Cooling Device Table Entry"
INDEX { coolingDeviceIndex }
::= { coolingDeviceTable 1 }
CoolingDeviceTableEntry ::= SEQUENCE {
coolingDeviceIndex OneBasedIndex,
coolingDeviceCIMDeviceId INTEGER,
coolingDeviceDescription DisplayString,
coolingDeviceStatusString DisplayString,
coolingDeviceStatus IntelStatus,
coolingDeviceReading INTEGER,
coolingDeviceUpperNonRecoverableThreshold INTEGER,
coolingDeviceUpperCriticalThreshold INTEGER,
coolingDeviceUpperNonCriticalThreshold INTEGER,
coolingDeviceLowerNonCriticalThreshold INTEGER,
coolingDeviceLowerCriticalThreshold INTEGER,
coolingDeviceLowerNonRecoverableThreshold INTEGER,
coolingDeviceResolution INTEGER,
coolingDeviceTolerance INTEGER,
coolingDeviceAccuracy INTEGER
}
coolingDeviceIndex OBJECT-TYPE
SYNTAX OneBasedIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the index (one based) of the cooling device."
::= { coolingDeviceTableEntry 1 }
coolingDeviceCIMDeviceId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the DeviceId used by the Intel CIM software
to uniquely identify the device, it represents the [channel#][sensor#][IPMB OwnerID][LUN]."
::= { coolingDeviceTableEntry 2 }
coolingDeviceDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute textually describes the cooling device."
::= { coolingDeviceTableEntry 3 }
coolingDeviceStatusString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current status of the sensor will be one of the
following strings: other, unknown, ok, nonCritical, critical, nonRecoverable."
::= { coolingDeviceTableEntry 4}
coolingDeviceStatus OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current health status of the sensor."
::= { coolingDeviceTableEntry 5 }
coolingDeviceReading OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute contains the current fan sensor
reading, measured in the units specified by the Fan Units attribute. 0x7fffffff (2147483647) denotes 'unknown'."
::= { coolingDeviceTableEntry 6 }
coolingDeviceUpperNonRecoverableThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This attribute contains the fatal error threshold
level for the fan. The threshold is given in the units specified by the Fan Units
attribute. This attribute may not apply to all fan types. 0x7fffffff (2147483647) denotes 'unknown'."
::= { coolingDeviceTableEntry 7 }
coolingDeviceUpperCriticalThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This attribute contains the major error threshold
level for the fan. The threshold is given in the units specified by the Fan Units
attribute. This attribute may not apply to all fan types. 0x7fffffff (2147483647) denotes 'unknown'."
::= { coolingDeviceTableEntry 8 }
coolingDeviceUpperNonCriticalThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This attribute contains the warning threshold level
for the fan. The threshold is given in the units specified by the Fan Units
attribute. This attribute may not apply to all fan types. 0x7fffffff (2147483647) denotes 'unknown'."
::= { coolingDeviceTableEntry 9 }
coolingDeviceLowerNonCriticalThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This attribute contains the lower warning threshold level
for the fan. The threshold is given in the units specified by the Fan Units
attribute. This attribute may not apply to all fan types. 0x7fffffff (2147483647) denotes 'unknown'."
::= { coolingDeviceTableEntry 10 }
coolingDeviceLowerCriticalThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This attribute contains the lower critical threshold level
for the fan. The threshold is given in the units specified by the Fan Units
attribute. This attribute may not apply to all fan types. 0x7fffffff (2147483647) denotes 'unknown'."
::= { coolingDeviceTableEntry 11 }
coolingDeviceLowerNonRecoverableThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This attribute contains the fatal error threshold
level for the fan. The threshold is given in the units specified by the Fan Units
attribute. This attribute may not apply to all fan types. 0x7fffffff (2147483647) denotes 'unknown'."
::= { coolingDeviceTableEntry 12 }
coolingDeviceResolution OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute describes the sensor's resolution. 0x7fffffff (2147483647) denotes 'unknown'."
::= { coolingDeviceTableEntry 13 }
coolingDeviceTolerance OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute describes the sensor's tolerance in
the units specified by the cooling device's units attrubite. 0x7fffffff (2147483647) denotes 'unknown'."
::= { coolingDeviceTableEntry 14 }
coolingDeviceAccuracy OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute describes the sensor's accuracy in
+/- hundredth of a percent. 0x7fffffff (2147483647) denotes 'unknown'."
::= { coolingDeviceTableEntry 15 }
-------------------------------------------------------------------------------
-- Discrete Cooling Device Table
-------------------------------------------------------------------------------
discreteCoolingDeviceTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiscreteCoolingDeviceTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Discrete Cooling Device Table."
::= { thermalGroup 30 }
discreteCoolingDeviceTableEntry OBJECT-TYPE
SYNTAX DiscreteCoolingDeviceTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Discrete Cooling Device Table Entry."
INDEX { discreteCoolingDeviceIndex }
::= { discreteCoolingDeviceTable 1 }
DiscreteCoolingDeviceTableEntry ::= SEQUENCE {
discreteCoolingDeviceIndex OneBasedIndex,
discreteCoolingDeviceCIMDeviceId INTEGER,
discreteCoolingDeviceDescription DisplayString,
discreteCoolingDeviceStatusString DisplayString,
discreteCoolingDeviceStatus IntelStatus,
discreteCoolingDevicePerformance INTEGER
}
discreteCoolingDeviceIndex OBJECT-TYPE
SYNTAX OneBasedIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the index (one based) of the discrete cooling device."
::= { discreteCoolingDeviceTableEntry 1 }
discreteCoolingDeviceCIMDeviceId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the DeviceId used by the Intel CIM software
to uniquely identify the device, it represents the [channel#][sensor#][IPMB OwnerID][LUN]."
::= { discreteCoolingDeviceTableEntry 2 }
discreteCoolingDeviceDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute textually describes the discrete cooling device."
::= { discreteCoolingDeviceTableEntry 3 }
discreteCoolingDeviceStatusString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current status of the sensor will be one of the
following strings: other, unknown, ok, nonCritical, critical, nonRecoverable."
::= { discreteCoolingDeviceTableEntry 4 }
discreteCoolingDeviceStatus OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current health status of the sensor."
::= { discreteCoolingDeviceTableEntry 5 }
discreteCoolingDevicePerformance OBJECT-TYPE
SYNTAX INTEGER {
met(1),
lags(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Describes whether or not the discrete cooling device meets performance
standards, or is lagging."
::= { discreteCoolingDeviceTableEntry 6 }
-------------------------------------------------------------------------------
-- Temperature Probe Table
-------------------------------------------------------------------------------
temperatureProbeTable OBJECT-TYPE
SYNTAX SEQUENCE OF TemperatureProbeTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Temperature Probe Table."
::= { thermalGroup 40 }
temperatureProbeTableEntry OBJECT-TYPE
SYNTAX TemperatureProbeTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Temperature Probe Table Entry."
INDEX { temperatureIndex }
::= { temperatureProbeTable 1 }
TemperatureProbeTableEntry ::= SEQUENCE {
temperatureIndex OneBasedIndex,
temperatureCIMDeviceId INTEGER,
temperatureDescription DisplayString,
temperatureStatusString DisplayString,
temperatureStatus IntelStatus,
temperatureReading INTEGER,
temperatureUpperNonRecoverableThreshold INTEGER,
temperatureUpperCriticalThreshold INTEGER,
temperatureUpperNonCriticalThreshold INTEGER,
temperatureLowerNonCriticalThreshold INTEGER,
temperatureLowerCriticalThreshold INTEGER,
temperatureLowerNonRecoverableThreshold INTEGER,
temperatureResolution INTEGER,
temperatureTolerance INTEGER,
temperatureAccuracy INTEGER
}
temperatureIndex OBJECT-TYPE
SYNTAX OneBasedIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the index (one based) of the temperature probe."
::= { temperatureProbeTableEntry 1}
temperatureCIMDeviceId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the DeviceId used by the Intel CIM software
to uniquely identify the device, it represents the [channel#][sensor#][IPMB OwnerID][LUN]."
::= { temperatureProbeTableEntry 2 }
temperatureDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute textually describes the temperature probe."
::= { temperatureProbeTableEntry 3}
temperatureStatusString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current status of the sensor will be one of the
following strings: other, unknown, ok, nonCritical, critical, nonRecoverable."
::= { temperatureProbeTableEntry 4}
temperatureStatus OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current health status of the sensor."
::= { temperatureProbeTableEntry 5 }
temperatureReading OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The present temperature reading of this temperature probe
in 1/10th degrees C. 0x7fffffff (2147483647) denotes 'unknown'."
::= { temperatureProbeTableEntry 6 }
temperatureUpperNonRecoverableThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The upper non-recoverable threshold for the temperature probe,
in 1/10th degrees C. 0x7fffffff (2147483647) denotes 'unknown'."
::= { temperatureProbeTableEntry 7 }
temperatureUpperCriticalThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The upper critical threshold for the temperature probe, in
/10th degrees C. 0x7fffffff (2147483647) denotes 'unknown'."
::= { temperatureProbeTableEntry 8 }
temperatureUpperNonCriticalThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The upper non-critical threshold for the temperature probe,
in 1/10th degrees C. 0x7fffffff (2147483647) denotes 'unknown'."
::= { temperatureProbeTableEntry 9 }
temperatureLowerNonCriticalThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The lower non-critical threshold for the temperature reading
setby the user, in 1/10th degrees C. 0x7fffffff (2147483647) denotes 'unknown'."
::= { temperatureProbeTableEntry 10 }
temperatureLowerCriticalThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The lower critical threshold for the temperature probe, in
1/10 degrees C. 0x7fffffff (2147483647) denotes 'unknown'."
::= { temperatureProbeTableEntry 11 }
temperatureLowerNonRecoverableThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The lower non-recoverable threshold for the temperature probe,
in 1/10th degrees C. 0x7fffffff (2147483647) denotes 'unknown'."
::= { temperatureProbeTableEntry 12 }
temperatureResolution OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The resolution for the reading from this temperature probe,
in tenths of 1/10th degrees C. '0x7fffffff (2147483647) denotes 'unknown'."
::= { temperatureProbeTableEntry 13 }
temperatureTolerance OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The tolerance for the reading from this temperature probe,
in plus/minus 1/10 degrees C. 0x7fffffff (2147483647) denotes 'unknown'."
::= { temperatureProbeTableEntry 14 }
temperatureAccuracy OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The accuracy for the reading from this temperature probe, in
plus/minus hundredths of a percent. 0x7fffffff (2147483647) denotes 'unknown' or'unsupported'."
::= { temperatureProbeTableEntry 15 }
--*****************************************************************************
--
-- DRIVE SLOT GROUP
--
--*****************************************************************************
-------------------------------------------------------------------------------
-- Drive Slot Presence Sensor Table
-------------------------------------------------------------------------------
driveSlotPresenceSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF DriveSlotPresenceSensorTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Drive Slot Presence Sensor Table."
::= { driveSlotGroup 10 }
driveSlotPresenceSensorTableEntry OBJECT-TYPE
SYNTAX DriveSlotPresenceSensorTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the Drive Slot Presence Sensor Table Entry."
INDEX { driveSlotPresenceSensorIndex }
::= { driveSlotPresenceSensorTable 1 }
DriveSlotPresenceSensorTableEntry ::= SEQUENCE {
driveSlotPresenceSensorIndex OneBasedIndex,
driveSlotPresenceSensorCIMDeviceId INTEGER,
driveSlotPresenceSensorDescription DisplayString,
driveSlotPresenceSensorStatusString DisplayString,
driveSlotPresenceSensorStatus IntelStatus,
driveSlotPresenceSensorPresenceStatusString DisplayString
}
driveSlotPresenceSensorIndex OBJECT-TYPE
SYNTAX OneBasedIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the index (one based) of the drive slot presence sensor."
::= { driveSlotPresenceSensorTableEntry 1 }
driveSlotPresenceSensorCIMDeviceId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the DeviceId used by the Intel CIM software
to uniquely identify the device, it represents the [channel#][sensor#][IPMB OwnerID][LUN]."
::= { driveSlotPresenceSensorTableEntry 2 }
driveSlotPresenceSensorDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute textually describes the drive slot presence sensor."
::= { driveSlotPresenceSensorTableEntry 3 }
driveSlotPresenceSensorStatusString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current status of the sensor will be one of the
following strings: ok, critical, or unknown."
::= { driveSlotPresenceSensorTableEntry 4 }
driveSlotPresenceSensorStatus OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current health status of the sensor."
::= { driveSlotPresenceSensorTableEntry 5 }
driveSlotPresenceSensorPresenceStatusString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current status of the sensor will be one of the
following strings: Device Removed/Absent or Device Inserted/Present."
::= { driveSlotPresenceSensorTableEntry 6 }
-------------------------------------------------------------------------------
-- MISCELLANEOUS Sensor Table
-------------------------------------------------------------------------------
miscellaneousSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF MiscellaneousSensorTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the miscellaneous Presence Sensor Table."
::= { miscellaneousGroup 10 }
miscellaneousSensorTableEntry OBJECT-TYPE
SYNTAX MiscellaneousSensorTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object defines the miscellaneous Sensor Table Entry."
INDEX { miscellaneousSensorIndex }
::= { miscellaneousSensorTable 1 }
MiscellaneousSensorTableEntry ::= SEQUENCE {
miscellaneousSensorIndex OneBasedIndex,
miscellaneousSensorCIMDeviceId INTEGER,
miscellaneousSensorDescription DisplayString,
miscellaneousSensorStatusString DisplayString,
miscellaneousSensorStatus IntelStatus
}
miscellaneousSensorIndex OBJECT-TYPE
SYNTAX OneBasedIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the index (one based) of the miscellaneous sensor."
::= { miscellaneousSensorTableEntry 1 }
miscellaneousSensorCIMDeviceId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute defines the DeviceId used by the Intel CIM software
to uniquely identify the device, it represents the [channel#][sensor#][IPMB OwnerID][LUN]."
::= { miscellaneousSensorTableEntry 2 }
miscellaneousSensorDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute textually describes the miscellaneous sensor."
::= { miscellaneousSensorTableEntry 3 }
miscellaneousSensorStatusString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current status of the miscellaneous sensor will be one of the
following strings: ok, critical, or unknown."
::= { miscellaneousSensorTableEntry 4 }
miscellaneousSensorStatus OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current health status of the miscellaneous sensor."
::= { miscellaneousSensorTableEntry 5 }
--*****************************************************************************
--
-- EVENTS
--
--*****************************************************************************
eventVariables OBJECT IDENTIFIER ::= { baseboard7EventGroup 10 }
eventDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Descriptive information about the event."
::= { eventVariables 1 }
eventSeverity OBJECT-TYPE
SYNTAX IntelStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Severity of the event"
::= { eventVariables 2 }
eventSlotDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Test string identifying the PHP slot group."
::= { eventVariables 3 }
eventSlotCIMDeviceId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The CIM Device ID of the slot reported on by the event."
::= { eventVariables 4 }
systemManagementSWEvents OBJECT IDENTIFIER ::= { baseboard7EventGroup 20 }
chassisEvents OBJECT IDENTIFIER ::= { baseboard7EventGroup 30 }
processorEvents OBJECT IDENTIFIER ::= { baseboard7EventGroup 40 }
powerEvents OBJECT IDENTIFIER ::= { baseboard7EventGroup 50 }
memoryEvents OBJECT IDENTIFIER ::= { baseboard7EventGroup 60 }
thermalEvents OBJECT IDENTIFIER ::= { baseboard7EventGroup 70 }
slotEvents OBJECT IDENTIFIER ::= { baseboard7EventGroup 80 }
systemEvents OBJECT IDENTIFIER ::= { baseboard7EventGroup 90 }
driveSlotEvents OBJECT IDENTIFIER ::= { baseboard7EventGroup 100 }
nmsmartclstEvents OBJECT IDENTIFIER ::= { baseboard7EventGroup 110 }
-------------------------------------------------------------------------------
-- System Management SW Events
-------------------------------------------------------------------------------
systemHealthOtherEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
systemManagementInfoOverallStatusHealth
}
STATUS current
DESCRIPTION "The overall server health is now a non-standard value of other."
--Novell NMS trap annotation
--TYPE "Server Health Other"
--SEVERITY INFORMATIONAL
--SUMMARY "The overall health of the server is other."
--CATEGORY "Error Alarms"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { systemManagementSWEvents 1 }
systemHealthUnknownEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
systemManagementInfoOverallStatusHealth
}
STATUS current
DESCRIPTION "The overall server health is now unknown."
--Novell NMS trap annotation
--TYPE "Server Health Unknown"
--SEVERITY INFORMATIONAL
--SUMMARY "The overall health of the server is unknown."
--CATEGORY "Error Alarms"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { systemManagementSWEvents 2 }
systemHealthOKEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
systemManagementInfoOverallStatusHealth
}
STATUS current
DESCRIPTION "The overall server health is now OK."
--Novell NMS trap annotation
--TYPE "Server Health OK"
--SEVERITY INFORMATIONAL
--SUMMARY "The overall health of the server is OK."
--CATEGORY "Error Alarms"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { systemManagementSWEvents 3 }
systemHealthNonCriticalEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
systemManagementInfoOverallStatusHealth
}
STATUS current
DESCRIPTION "The overall server health is now Degraded."
--Novell NMS trap annotation
--TYPE "Server Health Non-Critical"
--SEVERITY MAJOR
--SUMMARY "The overall health of the server is non-critical."
--CATEGORY "Error Alarms"
--STATE DEGRADED
--STATUS MANDATORY
::= { systemManagementSWEvents 4 }
systemHealthCriticalEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
systemManagementInfoOverallStatusHealth
}
STATUS current
DESCRIPTION "The overall server health is now Critical."
--Novell NMS trap annotation
--TYPE "Server Health Critical"
--SEVERITY CRITICAL
--SUMMARY "The overall health of the server is critical."
--CATEGORY "Error Alarms"
--STATE FAILED
--STATUS MANDATORY
::= { systemManagementSWEvents 5 }
systemHealthNonRecoverableEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
systemManagementInfoOverallStatusHealth
}
STATUS current
DESCRIPTION "The overall server health is now non-recoverable."
--Novell NMS trap annotation
--TYPE "Syerver Health Non-Recoverable"
--SEVERITY CRITICAL
--SUMMARY "The overall health of the server is non-recoverable."
--CATEGORY "Error Alarms"
--STATE FAILED
--STATUS MANDATORY
::= { systemManagementSWEvents 6 }
-------------------------------------------------------------------------------
-- Chassis Events
-------------------------------------------------------------------------------
chassisIntrusionDetectedEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
eventSeverity
}
STATUS current
DESCRIPTION "An intrusion to the chassis has been detected."
--Novell NMS trap annotation
--TYPE "Server Chassis Intrusion Detected"
--SEVERITY MINOR
--SUMMARY "An intrusion into the chassis has been detected."
--CATEGORY "Error Alarms"
--STATE OPERATIONAL
--STATUS OPTIONAL
::= { chassisEvents 1 }
chassisIntrusionClearedEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
eventSeverity
}
STATUS current
DESCRIPTION "The chassis intrusion is no longer detected."
--Novell NMS trap annotation
--TYPE "Server Chassis Intrusion Cleared"
--SEVERITY INFORMATIONAL
--SUMMARY "The intrusion into the chassis has been cleared."
--CATEGORY "Error Alarms"
--STATE OPERATIONAL
--STATUS OPTIONAL
::= { chassisEvents 2 }
-------------------------------------------------------------------------------
-- Processor Events
-------------------------------------------------------------------------------
processorIERREvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
processorStatus,
processorDescription,
processorCIMDeviceId
}
STATUS current
DESCRIPTION "The processor experienced an IERR (Internal Error)."
--Novell NMS trap annotation
--TYPE "Server Processor IERR"
--SEVERITY CRITICAL
--SUMMARY "Processor %s experienced an Internal Error."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE FAILED
--STATUS MANDATORY
::= { processorEvents 1 }
processorThermalTripEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
processorStatus,
processorDescription,
processorCIMDeviceId
}
STATUS current
DESCRIPTION "The proessor experienced a thermal trip."
--Novell NMS trap annotation
--TYPE "Server Processor Thermal Trip"
--SEVERITY CRITICAL
--SUMMARY "Processor %s experienced a thermal trip."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE FAILED
--STATUS MANDATORY
::= { processorEvents 2 }
processorFRB1Event NOTIFICATION-TYPE
OBJECTS {
eventDescription,
processorStatus,
processorDescription,
processorCIMDeviceId
}
STATUS current
DESCRIPTION "The processor experienced an FRB1 error, BIST failure."
--Novell NMS trap annotation
--TYPE "Server Processor FRB1 Error"
--SEVERITY CRITICAL
--SUMMARY "Processor %s experienced an FRB1 error, BIST failure."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE FAILED
--STATUS MANDATORY
::= { processorEvents 3 }
processorFRB2Event NOTIFICATION-TYPE
OBJECTS {
eventDescription,
processorStatus,
processorDescription,
processorCIMDeviceId
}
STATUS current
DESCRIPTION "The processor experienced an FRB2 error, hang in POST failure."
--Novell NMS trap annotation
--TYPE "Server Processor FRB2 Error"
--SEVERITY CRITICAL
--SUMMARY "Processor %s experienced an FRB2 error, hang in POST failure."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE FAILED
--STATUS MANDATORY
::= { processorEvents 4 }
processorFRB3Event NOTIFICATION-TYPE
OBJECTS {
eventDescription,
processorStatus,
processorDescription,
processorCIMDeviceId
}
STATUS current
DESCRIPTION "The processor experienced an FRB3 error, initialization failure."
--Novell NMS trap annotation
--TYPE "Server Processor FRB3 Error"
--SEVERITY CRITICAL
--SUMMARY "Processor %s experienced an FRB3 error, initialization failure."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE FAILED
--STATUS MANDATORY
::= { processorEvents 5 }
processorConfigurationErrorEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
processorStatus,
processorDescription,
processorCIMDeviceId
}
STATUS current
DESCRIPTION "The processor experienced a configuration error."
--Novell NMS trap annotation
--TYPE "Server Processor Configuration Error"
--SEVERITY CRITICAL
--SUMMARY "Processor %s experienced a configuration error."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE FAILED
--STATUS MANDATORY
::= { processorEvents 6 }
processorPresenceEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
processorStatus,
processorDescription,
processorCIMDeviceId
}
STATUS current
DESCRIPTION "The processor presence has been detected."
--Novell NMS trap annotation
--TYPE "Server Processor Detected"
--SEVERITY INFORMATIONAL
--SUMMARY "Processor %s has been detected."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { processorEvents 7 }
processorDisabledEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
processorStatus,
processorDescription,
processorCIMDeviceId
}
STATUS current
DESCRIPTION "The processor has been disabled."
--Novell NMS trap annotation
--TYPE "Server Processor Disabled"
--SEVERITY CRITICAL
--SUMMARY "Processor %s has been disabled."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE FAILED
--STATUS MANDATORY
::= { processorEvents 8 }
processorTerminatorEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
processorStatus,
processorDescription,
processorCIMDeviceId
}
STATUS current
DESCRIPTION "The processor terminator has been detected."
--Novell NMS trap annotation
--TYPE "Server Processor Terminator Detected"
--SEVERITY INFORMATIONAL
--SUMMARY "Processor %s terminator has been detected."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { processorEvents 9 }
processorSMBIOSUncorrectableCPUEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
processorStatus,
processorDescription,
processorCIMDeviceId
}
STATUS current
DESCRIPTION "The processor has encountered an SMBIOS Uncorrectable CPU-Complex error."
--Novell NMS trap annotation
--TYPE "Server Processor SMBIOS Error"
--SEVERITY CRITICAL
--SUMMARY "Processor %s has encountered an SMBIOS uncorrectable CPU-complex error."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE FAILED
--STATUS MANDATORY
::= { processorEvents 10 }
-------------------------------------------------------------------------------
-- Power Events - Power Unit Redundancy Events
-------------------------------------------------------------------------------
powerUnitFullyRedundantEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
powerUnitStatus,
powerUnitDescription,
powerUnitCIMDeviceId
}
STATUS current
DESCRIPTION "The power supply unit is fully redundant."
--Novell NMS trap annotation
--TYPE "Server Power Unit Redundancy Normal"
--SEVERITY INFORMATIONAL
--SUMMARY "The power unit is fully redundant."
--CATEGORY "Error Alarms"
--STATE OPERATIONAL
--STATUS OPTIONAL
::= { powerEvents 1}
powerUnitRedundancyDegradedEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
powerUnitStatus,
powerUnitDescription,
powerUnitCIMDeviceId
}
STATUS current
DESCRIPTION "The power supply unit redundancy has been degraded."
--Novell NMS trap annotation
--TYPE "Server Power Unit Redundancy Degraded"
--SEVERITY MINOR
--SUMMARY "The power unit redundancy has degraded."
--CATEGORY "Error Alarms"
--STATE DEGRADED
--STATUS OPTIONAL
::= { powerEvents 2 }
powerUnitRedundancyLostEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
powerUnitStatus,
powerUnitDescription,
powerUnitCIMDeviceId
}
STATUS current
DESCRIPTION "The power supply unit redundancy has been lost."
--Novell NMS trap annotation
--TYPE "Server Power Unit Redundancy Lost"
--SEVERITY MAJOR
--SUMMARY "The power unit redundancy has been lost."
--CATEGORY "Error Alarms"
--STATE DEGRADED
--STATUS OPTIONAL
::= { powerEvents 3 }
-------------------------------------------------------------------------------
-- Power Events - Power Supply Events
-------------------------------------------------------------------------------
powerSupplyPresentEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
powerSupplyStatus,
powerSupplyDescription,
powerSupplyCIMDeviceId
}
STATUS current
DESCRIPTION "The power supply presence has been detected."
--Novell NMS trap annotation
--TYPE "Server Power Supply Detected"
--SEVERITY INFORMATIONAL
--SUMMARY "The power supply %s has been detected."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { powerEvents 4 }
powerSupplyRemovalEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
powerSupplyStatus,
powerSupplyDescription,
powerSupplyCIMDeviceId
}
STATUS current
DESCRIPTION "The power supply is no longer detected as present."
--Novell NMS trap annotation
--TYPE "Server Power Supply Removed"
--SEVERITY INFORMATIONAL
--SUMMARY "The power supply %s has been removed."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE DEGRADED
--STATUS MANDATORY
::= { powerEvents 5 }
powerSupplyFailureEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
powerSupplyStatus,
powerSupplyDescription,
powerSupplyCIMDeviceId
}
STATUS current
DESCRIPTION "The power supply has failed."
--Novell NMS trap annotation
--TYPE "Server Power Supply Failed"
--SEVERITY CRITICAL
--SUMMARY "The power supply %s has failed."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE DEGRADED
--STATUS MANDATORY
::= { powerEvents 6 }
powerSupplyPredictedFailureEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
powerSupplyStatus,
powerSupplyDescription,
powerSupplyCIMDeviceId
}
STATUS current
DESCRIPTION "Failure of this power supply has been predicted."
--Novell NMS trap annotation
--TYPE "Server Power Supply Failure Predicted"
--SEVERITY MINOR
--SUMMARY "A failure has been predicted for power supply %d %s"
--ARGUMENTS {1,2}
--CATEGORY "Error Alarms"
--STATE DEGRADED
--STATUS MANDATORY
::= { powerEvents 7 }
powerSupplyACLostEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
powerSupplyStatus,
powerSupplyDescription,
powerSupplyCIMDeviceId
}
STATUS current
DESCRIPTION "The power supply A/C connection has been lost."
--Novell NMS trap annotation
--TYPE "Server Power Supply AC Connection Lost"
--SEVERITY MAJOR
--SUMMARY "The power supply %s has lost the AC connection."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE DEGRADED
--STATUS MANDATORY
::= { powerEvents 8 }
powerSupplyACOKEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
powerSupplyStatus,
powerSupplyDescription,
powerSupplyCIMDeviceId
}
STATUS current
DESCRIPTION "The power supply A/C connection is now OK."
--Novell NMS trap annotation
--TYPE "Server Power Supply AC Connection OK"
--SEVERITY INFORMATIONAL
--SUMMARY "The power supply %s AC connection is OK."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { powerEvents 9 }
-------------------------------------------------------------------------------
-- Power Events - Voltage Events
-------------------------------------------------------------------------------
voltageLowerNonRecoverableEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
voltageStatus,
voltageDescription,
voltageCIMDeviceId
}
STATUS current
DESCRIPTION "Current reading is below lower non-recoverable threshold. Status for
this sensor is non-recoverable."
--Novell NMS trap annotation
--TYPE "Server Voltage Non-Recoverable"
--SEVERITY CRITICAL
--SUMMARY "The voltage probe %s is below lower non-recoverable threshold."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE DEGRADED
--STATUS MANDATORY
::= { powerEvents 10 }
voltageLowerCriticalEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
voltageStatus,
voltageDescription,
voltageCIMDeviceId
}
STATUS current
DESCRIPTION "Current reading is below lower critical threshold. Status for this
sensor is critical."
--Novell NMS trap annotation
--TYPE "Server Voltage Critical"
--SEVERITY CRITICAL
--SUMMARY "The voltage probe %s is below lower critical threshold."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE DEGRADED
--STATUS MANDATORY
::= { powerEvents 11 }
voltageLowerNonCriticalEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
voltageStatus,
voltageDescription,
voltageCIMDeviceId
}
STATUS current
DESCRIPTION "Curret reading is below lower non-critical threshold. Status for this
sensor is non-critical."
--Novell NMS trap annotation
--TYPE "Server Voltage Non-Critical"
--SEVERITY MINOR
--SUMMARY "The voltage probe %s is below lower non-critical threshold."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE DEGRADED
--STATUS MANDATORY
::= { powerEvents 12 }
voltageOKEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
voltageStatus,
voltageDescription,
voltageCIMDeviceId
}
STATUS current
DESCRIPTION "Current reading is within normal thresholds, status is OK."
--Novell NMS trap annotation
--TYPE "Server Voltage OK"
--SEVERITY INFORMATIONAL
--SUMMARY "The voltage probe %s is OK."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { powerEvents 13 }
voltageUpperNonCriticalEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
voltageStatus,
voltageDescription,
voltageCIMDeviceId
}
STATUS current
DESCRIPTION "Current reading exceeds upper non-critical threshold. Status for this
sensor is non-critical."
--Novell NMS trap annotation
--TYPE "Server Voltage Upper Non-Critical"
--SEVERITY MINOR
--SUMMARY "The voltage probe %s exceeded upper non-critical threshold."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE DEGRADED
--STATUS MANDATORY
::= { powerEvents 14 }
voltageUpperCriticalEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
voltageStatus,
voltageDescription,
voltageCIMDeviceId
}
STATUS current
DESCRIPTION "Current reading exceeds upper critical threshold. Status for this
sensor is critical."
--Novell NMS trap annotation
--TYPE "Server Voltage Upper Critical"
--SEVERITY CRITICAL
--SUMMARY "The voltage probe %s excees upper critical threshold."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE FAILED
--STATUS MANDATORY
::= { powerEvents 15 }
voltageUpperNonRecoverableEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
voltageStatus,
voltageDescription,
voltageCIMDeviceId
}
STATUS current
DESCRIPTION "Current reading exceeds upper non-recoverable threshold. Status for this
sensor is non-recoverable."
--Novell NMS trap annotation
--TYPE "Server Voltage Upper Non-Recoverable"
--SEVERITY CRITICAL
--SUMMARY "Voltage probe %s exceeds upper non-recoverable threshold."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE FAILED
--STATUS OPTIONAL
::= { powerEvents 16 }
-------------------------------------------------------------------------------
-- Power Events - Discrete Voltage Events
-------------------------------------------------------------------------------
discreteVoltagePerformanceMetEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
discreteVoltageStatus,
discreteVoltageDescription,
discreteVoltageCIMDeviceId
}
STATUS current
DESCRIPTION "The discrete voltage sensor meets performance standards."
--Novell NMS trap annotation
--TYPE "Server Discrete Voltage OK"
--SEVERITY INFORMATIONAL
--SUMMARY "Discrete voltage probe %s performance met."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { powerEvents 17 }
discreteVoltagePerformanceLagsEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
discreteVoltageStatus,
discreteVoltageDescription,
discreteVoltageCIMDeviceId
}
STATUS current
DESCRIPTION "The discrete voltage sensor lags from performance standards."
--Novell NMS trap annotation
--TYPE "Server Discrete Voltage Probe Critical"
--SEVERITY CRITICAL
--SUMMARY "Discrete voltage probe %s performance lags."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE FAILED
--STATUS MANDATORY
::= { powerEvents 18 }
-------------------------------------------------------------------------------
-- Memory Events
-------------------------------------------------------------------------------
memorySingleBitErrorEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
physicalMemoryDeviceStatus,
physicalMemoryDeviceDescription,
physicalMemoryDeviceCIMDeviceId
}
STATUS current
DESCRIPTION "A single bit error occured in memory."
--Novell NMS trap annotation
--TYPE "Server Single Bit Memory Error"
--SEVERITY MINOR
--SUMMARY "Memory device %s experienced a single bit memory error."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE DEGRADED
--STATUS MANDATORY
::= { memoryEvents 1 }
memoryMultiBitErrorEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
physicalMemoryDeviceStatus,
physicalMemoryDeviceDescription,
physicalMemoryDeviceCIMDeviceId
}
STATUS current
DESCRIPTION "A multi-bit error occured in memory."
--Novell NMS trap annotation
--TYPE "Server Multi-Bit Memory Error"
--SEVERITY MAJOR
--SUMMARY "Memory device %s experienced a multi-bit memory error."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE DEGRADED
--STATUS MANDATORY
::= { memoryEvents 2 }
memoryParityErrorEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
physicalMemoryDeviceStatus,
physicalMemoryDeviceDescription,
physicalMemoryDeviceCIMDeviceId
}
STATUS current
DESCRIPTION "A parity error occured in memory."
--Novell NMS trap annotation
--TYPE "Server Parity Memory Error"
--SEVERITY MAJOR
--SUMMARY "Memory device %s experienced a parity error."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE DEGRADED
--STATUS MANDATORY
::= { memoryEvents 3 }
memoryScrubFailedEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
physicalMemoryDeviceStatus,
physicalMemoryDeviceDescription,
physicalMemoryDeviceCIMDeviceId
}
STATUS current
DESCRIPTION "Memory scrub failed (stuck bit) error occured in memory."
--Novell NMS trap annotation
--TYPE "Server Memory Scrub Failed Error"
--SEVERITY MAJOR
--SUMMARY "Memory device %s experienced a scrub failure (stuck bit) error."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE DEGRADED
--STATUS MANDATORY
::= { memoryEvents 4 }
memoryDeviceDisabledEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
physicalMemoryDeviceStatus,
physicalMemoryDeviceDescription,
physicalMemoryDeviceCIMDeviceId
}
STATUS current
DESCRIPTION "Memory device was disabled."
--Novell NMS trap annotation
--TYPE "Memory Device Disabled"
--SEVERITY MAJOR
--SUMMARY "Memory device %s was disabled."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE DEGRADED
--STATUS MANDATORY
::= { memoryEvents 5 }
memoryCorrectableErrorLimitReachedEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
physicalMemoryDeviceStatus,
physicalMemoryDeviceDescription,
physicalMemoryDeviceCIMDeviceId
}
STATUS current
DESCRIPTION "Correctable error logging limit reached for memory device."
--Novell NMS trap annotation
--TYPE "Memory Correctable Error Limit Reached"
--SEVERITY MAJOR
--SUMMARY "Memory device %s correctable error logging limit reached."
--ARGUMENTS {3}
--CATEGORY "Error Alarms"
--STATE DEGRADED
--STATUS MANDATORY
::= { memoryEvents 6 }
-------------------------------------------------------------------------------
-- Thermal Events - Cooling Unit Events
-------------------------------------------------------------------------------
coolingUnitFullyRedundantEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
coolingUnitStatus,
coolingUnitDescription,
coolingUnitCIMDeviceId
}
STATUS current
DESCRIPTION "Cooling Unit is fully redundany."
--Novell NMS trap annotation
--TYPE "Server Cooling Unit Redundancy Normal"
--SEVERITY INFORMATIONAL
--SUMMARY "The cooling unit is fully redundant."
--CATEGORY "Threshold Alarms"
--STATE OPERATIONAL
--STATUS OPTIONAL
::= { thermalEvents 1 }
coolingUnitRedundancyDegradedEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
coolingUnitStatus,
coolingUnitDescription,
coolingUnitCIMDeviceId
}
STATUS current
DESCRIPTION "Cooling Unit redundancy has been degraded."
--Novell NMS trap annotation
--TYPE "Cooling Unit "
--SEVERITY MINOR
--SUMMARY "The cooling unit redundancy has degraded."
--CATEGORY "Threshold Alarms"
--STATE DEGRADED
--STATUS OPTIONAL
::= { thermalEvents 2 }
coolingUnitRedundancyLostEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
coolingUnitStatus,
coolingUnitDescription,
coolingUnitCIMDeviceId
}
STATUS current
DESCRIPTION "Cooling Unit redundancy has been lost."
--Novell NMS trap annotation
--TYPE "Server Cooling Unit Redundancy Lost"
--SEVERITY MAJOR
--SUMMARY "The cooling unit redundancy has been lost."
--CATEGORY "Threshold Alarms"
--STATE DEGRADED
--STATUS OPTIONAL
::= { thermalEvents 3 }
-------------------------------------------------------------------------------
-- Thermal Events - Cooling Device Events
-------------------------------------------------------------------------------
coolingDeviceLowerNonRecoverableEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
coolingDeviceStatus,
coolingDeviceDescription,
coolingDeviceCIMDeviceId
}
STATUS current
DESCRIPTION "Current reading is below lower non-recoverable threshold. Status for
this sensor is non-recoverable."
--Novell NMS trap annotation
--TYPE "Server Cooling Device Lower Non-Recoverable"
--SEVERITY CRITICAL
--SUMMARY "Cooling device %s is below lower non-recoverable threshold."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE FAILED
--STATUS OPTIONAL
::= { thermalEvents 4 }
coolingDeviceLowerCriticalEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
coolingDeviceStatus,
coolingDeviceDescription,
coolingDeviceCIMDeviceId
}
STATUS current
DESCRIPTION "Current reading is below lower critical threshold. Status for this
sensor is critical."
--Novell NMS trap annotation
--TYPE "Server Cooling Device Critical"
--SEVERITY CRITICAL
--SUMMARY "Cooling device %s is below lowre critical threshold."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE FAILED
--STATUS MANDATORY
::= { thermalEvents 5 }
coolingDeviceLowerNonCriticalEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
coolingDeviceStatus,
coolingDeviceDescription,
coolingDeviceCIMDeviceId
}
STATUS current
DESCRIPTION "Curret reading is below lower non-critical threshold. Status for this
sensor is non-critical."
--Novell NMS trap annotation
--TYPE "Server Cooling Device Lower Non-Critical"
--SEVERITY MINOR
--SUMMARY "Cooling device %s is below lower non-critical threshold."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE DEGRADED
--STATUS MANDATORY
::= { thermalEvents 6 }
coolingDeviceOKEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
coolingDeviceStatus,
coolingDeviceDescription,
coolingDeviceCIMDeviceId
}
STATUS current
DESCRIPTION "Current reading is within normal thresholds, status is OK."
--Novell NMS trap annotation
--TYPE "Server Cooling Device OK"
--SEVERITY INFORMATIONAL
--SUMMARY "Cooling device %s is OK"
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { thermalEvents 7 }
coolingDeviceUpperNonCriticalEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
coolingDeviceStatus,
coolingDeviceDescription,
coolingDeviceCIMDeviceId
}
STATUS current
DESCRIPTION "Current reading exceeds upper non-critical threshold. Status for this
sensor is non-critical."
--Novell NMS trap annotation
--TYPE "Server Cooling Device "
--SEVERITY MINOR
--SUMMARY "Cooling device %s exceeds upper non-critical threshold."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE DEGRADED
--STATUS MANDATORY
::= { thermalEvents 8 }
coolingDeviceUpperCriticalEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
coolingDeviceStatus,
coolingDeviceDescription,
coolingDeviceCIMDeviceId
}
STATUS current
DESCRIPTION "Current reading exceeds upper critical threshold. Status for this
sensor is critical."
--Novell NMS trap annotation
--TYPE "Server Cooling Device Upper Critical"
--SEVERITY CRITICAL
--SUMMARY "Cooling device %s exceeds upper critical threshold."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE FAILED
--STATUS MANDATORY
::= { thermalEvents 9 }
coolingDeviceUpperNonRecoverableEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
coolingDeviceStatus,
coolingDeviceDescription,
coolingDeviceCIMDeviceId
}
STATUS current
DESCRIPTION "Current reading exceeds upper non-recoverable threshold. Status for this
sensor is non-recoverable."
--Novell NMS trap annotation
--TYPE "Server Cooling Upper Non-Recoverable"
--SEVERITY CRITICAL
--SUMMARY "Cooling device %s exceeded upper non-recoverable threshold."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE FAILED
--STATUS OPTIONAL
::= { thermalEvents 10 }
-------------------------------------------------------------------------------
-- Thermal Events - Discrete Cooling Device Events
-------------------------------------------------------------------------------
discreteCoolingDevicePerformanceMetEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
discreteCoolingDeviceStatus,
discreteCoolingDeviceDescription,
discreteCoolingDeviceCIMDeviceId
}
STATUS current
DESCRIPTION "The discrete cooling device meets performance standards."
--Novell NMS trap annotation
--TYPE "Server Discrete Cooling Device OK"
--SEVERITY INFORMATIONAL
--SUMMARY "Discrete cooling device %s performance met."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { thermalEvents 11 }
discreteCoolingDevicePerformanceLagsEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
discreteCoolingDeviceStatus,
discreteCoolingDeviceDescription,
discreteCoolingDeviceCIMDeviceId
}
STATUS current
DESCRIPTION "The discrete cooling device lags from performance standards."
--Novell NMS trap annotation
--TYPE "Server Discrete Cooling Device Critical"
--SEVERITY CRITICAL
--SUMMARY "Discrete cooling device %s performance lags."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE FAILED
--STATUS MANDATORY
::= { thermalEvents 12 }
-------------------------------------------------------------------------------
-- Thermal Events - Temperature Probe Events
-------------------------------------------------------------------------------
temperatureLowerNonRecoverableEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
temperatureStatus,
temperatureDescription,
temperatureCIMDeviceId
}
STATUS current
DESCRIPTION "Current reading is below lower non-recoverable threshold. Status for
this sensor is non-recoverable."
--Novell NMS trap annotation
--TYPE "Server Temperature Lower Non-Recoverable"
--SEVERITY CRITICAL
--SUMMARY "Temperature %s is below lower non-recoverable threshold."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE FAILED
--STATUS OPTIONAL
::= { thermalEvents 13 }
temperatureLowerCriticalEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
temperatureStatus,
temperatureDescription,
temperatureCIMDeviceId
}
STATUS current
DESCRIPTION "Current reading is below lower critical threshold. Status for this
sensor is critical."
--Novell NMS trap annotation
--TYPE "Server Temperature Lower Critical"
--SEVERITY CRITICAL
--SUMMARY "Temperature probe %s is below lower critical threshold."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE FAILED
--STATUS MANDATORY
::= { thermalEvents 14 }
temperatureLowerNonCriticalEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
temperatureStatus,
temperatureDescription,
temperatureCIMDeviceId
}
STATUS current
DESCRIPTION "Curret reading is below lower non-critical threshold. Status for this
sensor is non-critical."
--Novell NMS trap annotation
--TYPE "Server Temperature Lower Non-Critical"
--SEVERITY MINOR
--SUMMARY "Temperature probe %s is below lower non-critical threshold."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE DEGRADED
--STATUS MANDATORY
::= { thermalEvents 15 }
temperatureOKEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
temperatureStatus,
temperatureDescription,
temperatureCIMDeviceId
}
STATUS current
DESCRIPTION "Current reading is within normal thresholds, status is OK."
--Novell NMS trap annotation
--TYPE "Server Temperature OK"
--SEVERITY INFORMATIONAL
--SUMMARY "Temperature probe %s is OK."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { thermalEvents 16 }
temperatureUpperNonCriticalEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
temperatureStatus,
temperatureDescription,
temperatureCIMDeviceId
}
STATUS current
DESCRIPTION "Current reading exceeds upper non-critical threshold. Status for this
sensor is non-critical."
--Novell NMS trap annotation
--TYPE "Server Temperature Upper Non-Critical"
--SEVERITY MINOR
--SUMMARY "Temperature probe %s exceeded upper non-critical threshold."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE DEGRADED
--STATUS MANDATORY
::= { thermalEvents 17 }
temperatureUpperCriticalEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
temperatureStatus,
temperatureDescription,
temperatureCIMDeviceId
}
STATUS current
DESCRIPTION "Current reading exceeds upper critical threshold. Status for this
sensor is critical."
--Novell NMS trap annotation
--TYPE "Server Temperature Upper Critical"
--SEVERITY CRITICAL
--SUMMARY "Temperature probe %s exceeded upper critical threshold."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE FAILED
--STATUS MANDATORY
::= { thermalEvents 18 }
temperatureUpperNonRecoverableEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
temperatureStatus,
temperatureDescription,
temperatureCIMDeviceId
}
STATUS current
DESCRIPTION "Current reading exceeds upper non-recoverable threshold. Status for this
sensor is non-recoverable."
--Novell NMS trap annotation
--TYPE "Server Temperature Upper Non-Recoverable"
--SEVERITY CRITICAL
--SUMMARY "Temperature probe %s exceeds upper non-recoverable threshold."
--ARGUMENTS {3}
--CATEGORY "Threshold Alarms"
--STATE FAILED
--STATUS OPTIONAL
::= { thermalEvents 19 }
-------------------------------------------------------------------------------
-- Slot Events
-------------------------------------------------------------------------------
slotOKEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
eventSeverity,
eventSlotDescription,
eventSlotCIMDeviceId
}
STATUS current
DESCRIPTION "The slot is OK."
--Novell NMS trap annotation
--TYPE "Server Slot OK"
--SEVERITY INFORMATIONAL
--SUMMARY "Slot %d is now OK."
--ARGUMENTS {4}
--CATEGORY "Error Alarms"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { slotEvents 1 }
slotFaultAssertedEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
eventSeverity,
eventSlotDescription,
eventSlotCIMDeviceId
}
STATUS current
DESCRIPTION "A fault has been detected on the slot."
--Novell NMS trap annotation
--TYPE "Server Slot Faulted"
--SEVERITY MAJOR
--SUMMARY "Slot %d has experienced a fault."
--ARGUMENTS {4}
--CATEGORY "Error Alarms"
--STATE FAILED
--STATUS MANDATORY
::= { slotEvents 2 }
slotPowerIsOffEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
eventSeverity,
eventSlotDescription,
eventSlotCIMDeviceId
}
STATUS current
DESCRIPTION "The slot is powered OFF."
--Novell NMS trap annotation
--TYPE "Server Slot Powered OFF"
--SEVERITY INFORMATIONAL
--SUMMARY "Slot %d is now powered OFF."
--ARGUMENTS {4}
--CATEGORY "Error Alarms"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { slotEvents 3 }
slotPowerIsOnEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
eventSeverity,
eventSlotDescription,
eventSlotCIMDeviceId
}
STATUS current
DESCRIPTION "Server slot powered ON."
--Novell NMS trap annotation
--TYPE "Server Slot Powered ON"
--SEVERITY INFORMATIONAL
--SUMMARY "Slot %d is now powered ON."
--ARGUMENTS {4}
--CATEGORY "Error Alarms"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { slotEvents 4 }
-------------------------------------------------------------------------------
-- System Events
-------------------------------------------------------------------------------
systemReconfiguredEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
eventSeverity
}
STATUS current
DESCRIPTION "The system BIOS has been reconfigured."
--Novell NMS trap annotation
--TYPE "System BIOS reconfigured"
--SEVERITY INFORMATIONAL
--SUMMARY "The system BIOS has been reconfigured."
--CATEGORY "LOGONLY"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { systemEvents 1 }
systemBootEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
eventSeverity
}
STATUS current
DESCRIPTION "The system has booted."
--Novell NMS trap annotation
--TYPE "System boot event"
--SEVERITY INFORMATIONAL
--SUMMARY "The system has booted."
--CATEGORY "LOGONLY"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { systemEvents 2 }
systemUndeterminedHardwareFailureEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
eventSeverity
}
STATUS current
DESCRIPTION "The system has experienced an undetermined hardware failure."
--Novell NMS trap annotation
--TYPE "System undetermined hardware failure"
--SEVERITY INFORMATIONAL
--SUMMARY "The system experienced an undetermined hardware failure."
--CATEGORY "Error Alarms"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { systemEvents 3 }
-------------------------------------------------------------------------------
-- Drive Slot Events - Drive Slot Presence Sensor Events
-------------------------------------------------------------------------------
driveSlotDeviceRemovedEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
driveSlotPresenceSensorStatus,
driveSlotPresenceSensorDescription,
driveSlotPresenceSensorCIMDeviceId
}
STATUS current
DESCRIPTION "The device has been removed from the drive slot."
--Novell NMS trap annotation
--TYPE "Server Drive Slot Device Removed"
--SEVERITY INFORMATIONAL
--SUMMARY "The device has been removed from the drive slot %s."
--ARGUMENTS {2}
--CATEGORY "Error Alarms"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { driveSlotEvents 1 }
driveSlotDeviceInsertedEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
driveSlotPresenceSensorStatus,
driveSlotPresenceSensorDescription,
driveSlotPresenceSensorCIMDeviceId
}
STATUS current
DESCRIPTION "The device has been inserted in the drive slot."
--Novell NMS trap annotation
--TYPE "Server Drive Slot Device Inserted"
--SEVERITY INFORMATIONAL
--SUMMARY "The device has been inserted in the drive slot %s."
--ARGUMENTS {2}
--CATEGORY "Error Alarms"
--STATE OPERATIONAL
--STATUS MANDATORY
::= { driveSlotEvents 2 }
-------------------------------------------------------------------------------
-- NMSmaRTCLST Events
-------------------------------------------------------------------------------
nmSmartclstAssertedEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
eventSeverity
}
STATUS current
DESCRIPTION "NM SmaRTCLST has been asserted."
--Novell NMS trap annotation
--TYPE "NM SmaRTCLST asserted."
--SEVERITY CRITICAL
--SUMMARY "NM SmaRTCLST has been asserted."
--CATEGORY "Error Alarms"
--STATE OPERATIONAL
--STATUS OPTIONAL
::= { nmsmartclstEvents 1 }
nmSmartclstDeassertedEvent NOTIFICATION-TYPE
OBJECTS {
eventDescription,
eventSeverity
}
STATUS current
DESCRIPTION "NM SmaRTCLST has been deasserted."
--Novell NMS trap annotation
--TYPE "NM SmaRTCLST deasserted."
--SEVERITY INFORMATIONAL
--SUMMARY "NM SmaRTCLST has been deasserted."
--CATEGORY "Error Alarms"
--STATE OPERATIONAL
--STATUS OPTIONAL
::= { nmsmartclstEvents 2 }
END