Observium_CE/mibs/fscom/NGPON-MIB

11998 lines
378 KiB
Plaintext
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

------------------------------------------------------------------------------
--
-- File : ngponMib.mi2
-- Description : gpon new platform configuration MIB
-- Version : 1.0
-- Date : July 14, 2016
-- Copyright (c) 2016-2020 Genexis Systems, Inc. All Rights Reserved.
--
------------------------------------------------------------------------------
NGPON-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Counter32, Unsigned32, TimeTicks FROM SNMPv2-SMI
TimeInterval, RowStatus, TruthValue,
TEXTUAL-CONVENTION, MacAddress FROM SNMPv2-TC
dataCom FROM ADMIN-MASTER-MIB
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF;
ngpon OBJECT IDENTIFIER ::= { dataCom 14 }
-- gpon function ------------------------------------------
gponConfig OBJECT IDENTIFIER ::= { ngpon 1 }
gponStatus OBJECT IDENTIFIER ::= { ngpon 2 }
oemTrue OBJECT IDENTIFIER ::= { ngpon 3 }
gponSwitch OBJECT IDENTIFIER ::= { ngpon 4 }
configDevice OBJECT IDENTIFIER ::= { gponConfig 1 }
configSlot OBJECT IDENTIFIER ::= { gponConfig 2 }
configPport OBJECT IDENTIFIER ::= { gponConfig 3 }
configOnt OBJECT IDENTIFIER ::= { gponConfig 4 }
statusDevice OBJECT IDENTIFIER ::= { gponStatus 1 }
statusSlot OBJECT IDENTIFIER ::= { gponStatus 2 }
statusPport OBJECT IDENTIFIER ::= { gponStatus 3 }
statusOnt OBJECT IDENTIFIER ::= { gponStatus 4 }
statusTrap OBJECT IDENTIFIER ::= { gponStatus 5 }
--------------------------------------------------------------
------------------ 1.1. config device ----------------------
--------------------------------------------------------------
-- 1.1.1. deployControl
-- 1.1.2. deployInactive
-- 1.1.3. deployActive
-- 1.1.4. deployDemo
-- 1.1.5. configDeviceBaseInfo
-- 1.1.1. deployControl ------------------------------------
deployControl OBJECT IDENTIFIER ::= { configDevice 1 }
deployPermission OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set deployPermission = 0 to request permission.
Set deployPermission = 1 to release permission.
When read, the value is always 0."
::= { deployControl 1 }
deployAction OBJECT-TYPE
SYNTAX INTEGER (0..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set deployAction = 0 to active the deploy.
Set deployAction = 1 to rebuild the deploy.
Set deployAction = 2 to clear the deploy.
When read, the value is always 0."
::= { deployControl 2 }
-- 1.1.2. deployInactive ----------------------------------
deployInactive OBJECT IDENTIFIER ::= { configDevice 2 }
-- 1.1.2.1. inactiveTrafficConfig
-- 1.1.2.2. inactiveDbaTable
-- 1.1.2.3. inactiveLineCommonConfig
-- 1.1.2.4. inactiveLineSFUConfig
-- 1.1.2.5. inactiveLineHGUConfig
-- 1.1.2.6. inactiveRuleTable
-- 1.1.2.7. inactiveUniqueConfig
-- 1.1.2.8. inactiveCtrlMcastConfig
-- 1.1.2.9. inactiveCtrlAlarmConfig
-- 1.1.2.1. inactiveTrafficConfig --------------------------
inactiveTrafficConfig OBJECT IDENTIFIER ::= { deployInactive 1 }
-- 1.1.2.1.1. inactiveVlanTable
-- 1.1.2.1.2. inactiveUsTrafficTable
-- 1.1.2.1.3. inactiveDsTrafficTable
-- 1.1.2.1.4. inactiveVlanPrimaryTable
-- 1.1.2.1.1. inactiveVlanTable --------------------------
inactiveVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive vlan table."
::= { inactiveTrafficConfig 1 }
inactiveVlanEntry OBJECT-TYPE
SYNTAX InactiveVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive vlan table"
INDEX { inactiveVlanIndex, inactiveVlanSubIndex }
::= { inactiveVlanTable 1 }
InactiveVlanEntry ::=
SEQUENCE
{
inactiveVlanIndex INTEGER,
inactiveVlanSubIndex INTEGER,
inactiveVlanAction INTEGER,
inactiveVlanOldVid INTEGER,
inactiveVlanOldPriority INTEGER,
inactiveVlanNewVid INTEGER,
inactiveVlanNewPriority INTEGER,
inactiveVlanRowStatus RowStatus
}
inactiveVlanIndex OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of inactive vlan table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveVlanEntry 1 }
inactiveVlanSubIndex OBJECT-TYPE
SYNTAX INTEGER(1..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 2nd index of inactive vlan table, should be inputted with <1-32>."
::= { inactiveVlanEntry 2 }
inactiveVlanAction OBJECT-TYPE
SYNTAX INTEGER(0..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveVlanAction:
0 NULL
1 translate
2 add
3 add default"
::= { inactiveVlanEntry 3 }
inactiveVlanOldVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"old vid, or inner vid, should in <1-4094>."
::= { inactiveVlanEntry 4 }
inactiveVlanOldPriority OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"old priority, or inner priority, should in <0-7>."
::= { inactiveVlanEntry 5 }
inactiveVlanNewVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"new vid, or outer vid, or default vid, should in <1-4094>."
::= { inactiveVlanEntry 6 }
inactiveVlanNewPriority OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"new priority, or outer priority, or default priority, should in <0-7>."
::= { inactiveVlanEntry 7 }
inactiveVlanRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveVlanEntry 8 }
-- 1.1.2.1.2. inactiveUsTrafficTable --------------------------
inactiveUsTrafficTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveUsTrafficEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive us traffic table."
::= { inactiveTrafficConfig 2 }
inactiveUsTrafficEntry OBJECT-TYPE
SYNTAX InactiveUsTrafficEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive us traffic table"
INDEX { inactiveUsTrafficIndex }
::= { inactiveUsTrafficTable 1 }
InactiveUsTrafficEntry ::=
SEQUENCE
{
inactiveUsTrafficIndex INTEGER,
inactiveUsTrafficName OCTET STRING,
inactiveUsTrafficPq INTEGER,
inactiveUsTrafficCir INTEGER,
inactiveUsTrafficPir INTEGER,
inactiveUsTrafficCbs INTEGER,
inactiveUsTrafficPbs INTEGER,
inactiveUsTrafficRowStatus RowStatus
}
inactiveUsTrafficIndex OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of inactive us traffic table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveUsTrafficEntry 1 }
inactiveUsTrafficName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"us traffic name, max length: 128."
::= { inactiveUsTrafficEntry 2 }
inactiveUsTrafficPq OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gemport priority queue, should be inputted with <0-7>."
::= { inactiveUsTrafficEntry 3 }
inactiveUsTrafficCir OBJECT-TYPE
SYNTAX INTEGER(64..1310720)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gemport committed infomation rate, should be inputted with <64-10240000>.
must to be divisible by 64kbps,must not less than 64 kbps."
::= { inactiveUsTrafficEntry 4 }
inactiveUsTrafficPir OBJECT-TYPE
SYNTAX INTEGER(64..1310720)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gemport peek infomation rate, should be inputted with <64-10240000>.
must to be divisible by 64kbps,must not less than 64 kbps."
::= { inactiveUsTrafficEntry 5 }
inactiveUsTrafficCbs OBJECT-TYPE
SYNTAX INTEGER(2000..1310720)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gemport committed burst size, should be inputted with <2000-10240000>."
::= { inactiveUsTrafficEntry 6 }
inactiveUsTrafficPbs OBJECT-TYPE
SYNTAX INTEGER(2000..1310720)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gemport peek burst size, should be inputted with <2000-10240000>."
::= { inactiveUsTrafficEntry 7 }
inactiveUsTrafficRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveUsTrafficEntry 8 }
-- 1.1.2.1.2. inactiveDsTrafficTable --------------------------
inactiveDsTrafficTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveDsTrafficEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive ds traffic table."
::= { inactiveTrafficConfig 3 }
inactiveDsTrafficEntry OBJECT-TYPE
SYNTAX InactiveDsTrafficEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive ds traffic table"
INDEX { inactiveDsTrafficIndex }
::= { inactiveDsTrafficTable 1 }
InactiveDsTrafficEntry ::=
SEQUENCE
{
inactiveDsTrafficIndex INTEGER,
inactiveDsTrafficName OCTET STRING,
inactiveDsTrafficRate INTEGER,
inactiveDsTrafficBurst INTEGER,
inactiveDsTrafficRowStatus RowStatus
}
inactiveDsTrafficIndex OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of inactive ds traffic table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveDsTrafficEntry 1 }
inactiveDsTrafficName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ds traffic name, max length: 128."
::= { inactiveDsTrafficEntry 2 }
inactiveDsTrafficRate OBJECT-TYPE
SYNTAX INTEGER(0..1677215)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gemport ds bandwidth rate, should be inputted with <0-1677215>."
::= { inactiveDsTrafficEntry 3 }
inactiveDsTrafficBurst OBJECT-TYPE
SYNTAX INTEGER(0..1677215)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gemport ds burst size, should be inputted with <0-1677215>."
::= { inactiveDsTrafficEntry 4 }
inactiveDsTrafficRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveDsTrafficEntry 5 }
-- 1.1.2.1.1. inactiveVlanPrimaryTable --------------------------
inactiveVlanPrimaryTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveVlanPrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive vlan primary table."
::= { inactiveTrafficConfig 4 }
inactiveVlanPrimaryEntry OBJECT-TYPE
SYNTAX InactiveVlanPrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive vlan primary table"
INDEX { inactiveVlanPriIndex }
::= { inactiveVlanPrimaryTable 1 }
InactiveVlanPrimaryEntry ::=
SEQUENCE
{
inactiveVlanPriIndex INTEGER,
inactiveVlanPriName OCTET STRING,
inactiveVlanPriRowStatus RowStatus
}
inactiveVlanPriIndex OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of inactive vlan table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveVlanPrimaryEntry 1 }
inactiveVlanPriName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"name of inactive vlan entry."
::= { inactiveVlanPrimaryEntry 2 }
inactiveVlanPriRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveVlanPrimaryEntry 3 }
-- 1.1.2.2. inactiveDbaTable ------------------------------
inactiveDbaTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveDbaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain dba table"
::= { deployInactive 2 }
inactiveDbaEntry OBJECT-TYPE
SYNTAX InactiveDbaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive dba table"
INDEX { inactiveDbaIndex }
::= { inactiveDbaTable 1 }
InactiveDbaEntry ::=
SEQUENCE
{
inactiveDbaIndex INTEGER,
inactiveDbaName OCTET STRING,
inactiveDbaType INTEGER,
inactiveDbaFixBandwidth INTEGER,
inactiveDbaAssuredBandwidth INTEGER,
inactiveDbaMaxBandwidth INTEGER,
inactiveDbaRowStatus RowStatus,
inactiveDbaMethod INTEGER
}
inactiveDbaIndex OBJECT-TYPE
SYNTAX INTEGER(0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of inactive dba table, should be inputted with <0-127>."
::= { inactiveDbaEntry 1 }
inactiveDbaName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactive dba name, max length: 128."
::= { inactiveDbaEntry 2 }
inactiveDbaType OBJECT-TYPE
SYNTAX INTEGER(1..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveDbaType,
1 fixed bandwidth
2 assured bandwidth
3 assured and max bandwidth
4 max bandwidth
5 fixed and assured and max bandwidth"
::= { inactiveDbaEntry 3 }
inactiveDbaFixBandwidth OBJECT-TYPE
SYNTAX INTEGER(128..1310720)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Must to be divisible by 64kbps, must not less than 128 kbps."
::= { inactiveDbaEntry 4 }
inactiveDbaAssuredBandwidth OBJECT-TYPE
SYNTAX INTEGER(0..1310592)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Must to be divisible by 64kbps, Can be 0.
If not 0, it must be at least 256 kbps."
::= { inactiveDbaEntry 5 }
inactiveDbaMaxBandwidth OBJECT-TYPE
SYNTAX INTEGER(0..1310720)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Must to be divisible by 64kbps, and must not be less than
the sum of assured BW plus fixedBW.
Must less than 1310720 kbps"
::= { inactiveDbaEntry 6 }
inactiveDbaRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveDbaEntry 7 }
inactiveDbaMethod OBJECT-TYPE
SYNTAX INTEGER {
NSR(0),
SR(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"dba method.
0(default): not SR
1: SR"
::= { inactiveDbaEntry 8 }
-- 1.1.2.3. inactiveLineCommonConfig ----------------------
inactiveLineCommonConfig OBJECT IDENTIFIER ::= { deployInactive 3 }
-- 1.1.2.3.1. inactiveLinePrimaryTable
-- 1.1.2.3.2. inactiveLineTcontTable
-- 1.1.2.3.3. inactiveLineGemportTable
-- 1.1.2.3.4. inactiveLineFlowmappingTable
-- 1.1.2.3.5. inactiveLineAttrMgmtTable
-- 1.1.2.3.6. inactiveLineCportTable
-- 1.1.2.3.7. inactiveLineAlarmRefTable
-- 1.1.2.3.1. inactiveLinePrimaryTable --------------------
inactiveLinePrimaryTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveLinePrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain line primary table"
::= { inactiveLineCommonConfig 1 }
inactiveLinePrimaryEntry OBJECT-TYPE
SYNTAX InactiveLinePrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive line primary table"
INDEX { inactiveLineIndex }
::= { inactiveLinePrimaryTable 1 }
InactiveLinePrimaryEntry ::=
SEQUENCE
{
inactiveLineIndex INTEGER,
inactiveLineDeviceType OCTET STRING,
inactiveLineName OCTET STRING,
inactiveLineTrafficMode INTEGER,
inactiveLineMappingMode INTEGER,
inactiveLineRowStatus RowStatus,
inactiveLineFecSwitch INTEGER
}
inactiveLineIndex OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of line primary table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveLinePrimaryEntry 1 }
inactiveLineDeviceType OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(7..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineDeviceType:
x30-420 4ETH+2POTS SFU
t10-100 1ETH SFU
t10-420 4ETH+2POTS SFU
t10-214 2ETH(1ETH+1iTV)+1POTS SFU
t10-423 4ETH+2POTS+WIFI+USB HGU
t10-427 4ETH(3ETH+1iTV)+2POTS+WIFI+USB HGU
t10-403 4ETH+WIFI+USB HGU
t60-100 1ETH SFU
c40-100 1ETH SFU
c30-420 4ETH+2POTS SFU
c40-427 4ETH(3ETH+1iTV)+2POTS+WIFI+USB HGU
c30-401 4ETH+WIFI HGU
c30-423 4ETH+2POTS+WIFI+USB HGU
c31-423 4ETH+2POTS+WIFI+USB HGU+SFU
c30-214 2ETH(1ETH+1iTV)+1POTS SFU
c40-210 1GE+1FE+1POTS HGU
c30-400 4ETH SFU
c40-201 2ETH+WIFI HGU
c40-429 4ETH+2POTS+CATV+WIFI HGU
c40-428 4ETH+2POTS+CATV HGU
c40-218 2ETH+1POTS+CATV HGU
m50-420 4ETH+2POTS SFU
f10-427 4ETH(3ETH+1iTV)+2POTS+WIFI+USB HGU
h60-100 1ETH SFU
s10-214 2ETH(1ETH+1iTV)+1POTS HGU
s30-100 1ETH SFU
n20-100 1ETH SFU
n20-400 4ETH SFU
n40-100 1ETH SFU
n70-400 4ETH SFU
n71-400 4ETH SFU
n71-408 4ETH+CATV SFU
n71-401 4ETH+WIFI HGU
n71-409 4ETH+CATV+WIFI HGU
n40-428-1 4ETH+2POTS+CATV+PoE HGU
n40-100-1 1ETH+PoE SFU
n40-400-1 4ETH+PoE SFU
n40-420-1 4ETH+2POTS+PoE HGU
n40-429 4ETH+2POTS+CATV+WIFI HGU
n40-800-1 8ETH+PoE MDU
d10-423 4ETH+2POTS+WIFI+USB HGU
l30-100 1ETH SFU
l30-210 2ETH+1POTS SFU
g40-108 1ETH+CATV SFU"
::= { inactiveLinePrimaryEntry 2 }
inactiveLineName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"line name, max length: 128."
::= { inactiveLinePrimaryEntry 3 }
inactiveLineTrafficMode OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineTrafficMode:
0 pri-queue: priority queue scheduling
1 gem-car: GEM traffic control"
::= { inactiveLinePrimaryEntry 4 }
inactiveLineMappingMode OBJECT-TYPE
SYNTAX INTEGER(0..6)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineMappingMode:
0 vlan
1 priority
2 vlan-priority
3 port
4 port-vlan
5 port-priority
6 port-vlan-priority"
::= { inactiveLinePrimaryEntry 5 }
inactiveLineRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveLinePrimaryEntry 6 }
inactiveLineFecSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineFecSwitch:
0 false (default)
1 true"
::= { inactiveLinePrimaryEntry 7 }
-- 1.1.2.3.2. inactiveLineTcontTable ----------------------
inactiveLineTcontTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveLineTcontEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain line tcont table, now only for tcont bind dba."
::= { inactiveLineCommonConfig 2 }
inactiveLineTcontEntry OBJECT-TYPE
SYNTAX InactiveLineTcontEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive line tcont table"
INDEX { inactiveLineIndexI, inactiveLineTcontIndex }
::= { inactiveLineTcontTable 1 }
InactiveLineTcontEntry ::=
SEQUENCE
{
inactiveLineIndexI INTEGER,
inactiveLineTcontIndex INTEGER,
inactiveLineTcontDbaIndex INTEGER,
inactiveLineTcontRowStatus RowStatus
}
inactiveLineIndexI OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 1st index of this table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveLineTcontEntry 1 }
inactiveLineTcontIndex OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of tcont, the 2nd index of this table.
Should in <1-8>."
::= { inactiveLineTcontEntry 2 }
inactiveLineTcontDbaIndex OBJECT-TYPE
SYNTAX INTEGER(0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The index of tcont bind dba, should be inputted with <0-127>."
::= { inactiveLineTcontEntry 3 }
inactiveLineTcontRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveLineTcontEntry 4 }
-- 1.1.2.3.3. inactiveLineGemportTable --------------------
inactiveLineGemportTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveLineGemportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain line gemport table."
::= { inactiveLineCommonConfig 3 }
inactiveLineGemportEntry OBJECT-TYPE
SYNTAX InactiveLineGemportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive line gemport table"
INDEX { inactiveLineIndexII, inactiveLineGemportIndex }
::= { inactiveLineGemportTable 1 }
InactiveLineGemportEntry ::=
SEQUENCE
{
inactiveLineIndexII INTEGER,
inactiveLineGemportIndex INTEGER,
inactiveLineGemportTcontId INTEGER,
inactiveLineGemportVlanProfileId INTEGER,
inactiveLineGemportUsProfileId INTEGER,
inactiveLineGemportDsProfileId INTEGER,
inactiveLineGemportRowStatus RowStatus
}
inactiveLineIndexII OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 1st index of this table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveLineGemportEntry 1 }
inactiveLineGemportIndex OBJECT-TYPE
SYNTAX INTEGER(1..24)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of gemport, the 2nd index of this table.
Should in <1-24>."
::= { inactiveLineGemportEntry 2 }
inactiveLineGemportTcontId OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gemport bind tcont index, should be inputted with <1-8>."
::= { inactiveLineGemportEntry 3 }
inactiveLineGemportVlanProfileId OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gemport vlan profile id, should be inputted with <0-4095>."
::= { inactiveLineGemportEntry 4 }
inactiveLineGemportUsProfileId OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gemport us traffic profile id, should be inputted with <0-4095>."
::= { inactiveLineGemportEntry 5 }
inactiveLineGemportDsProfileId OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gemport ds traffic profile id, should be inputted with <0-4095>."
::= { inactiveLineGemportEntry 6 }
inactiveLineGemportRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveLineGemportEntry 7 }
-- 1.1.2.3.4. inactiveLineFlowmappingTable ----------------
inactiveLineFlowmappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveLineFlowmappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain line flow mapping table."
::= { inactiveLineCommonConfig 4 }
inactiveLineFlowmappingEntry OBJECT-TYPE
SYNTAX InactiveLineFlowmappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive line flow mapping table"
INDEX { inactiveLineIndexIII, inactiveLineFlowmappingIndex }
::= { inactiveLineFlowmappingTable 1 }
InactiveLineFlowmappingEntry ::=
SEQUENCE
{
inactiveLineIndexIII INTEGER,
inactiveLineFlowmappingIndex INTEGER,
inactiveLineFlowmappingVid INTEGER,
inactiveLineFlowmappingPriority INTEGER,
inactiveLineFlowmappingEthport INTEGER,
inactiveLineFlowmappingGemport INTEGER,
inactiveLineFlowmappingType INTEGER,
inactiveLineFlowmappingRowStatus RowStatus
}
inactiveLineIndexIII OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 1st index of this table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveLineFlowmappingEntry 1 }
inactiveLineFlowmappingIndex OBJECT-TYPE
SYNTAX INTEGER(0..47)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of flowmapping, the 2nd index of this table. Should in <1-48>.
The range is not always fit, please see range in commands."
::= { inactiveLineFlowmappingEntry 2 }
inactiveLineFlowmappingVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The flow mapping vid, should be inputted with <1-4094>."
::= { inactiveLineFlowmappingEntry 3 }
inactiveLineFlowmappingPriority OBJECT-TYPE
SYNTAX INTEGER(0..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The flow mapping priority, should be inputted with <0-8>.
default value 8 means don't care 802.1p priority."
::= { inactiveLineFlowmappingEntry 4 }
inactiveLineFlowmappingEthport OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The flow mapping ethernet port id, should be inputted with <1-8>."
::= { inactiveLineFlowmappingEntry 5 }
inactiveLineFlowmappingGemport OBJECT-TYPE
SYNTAX INTEGER(1..24)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The flow mapping gem port id, should be inputted with <1-24>."
::= { inactiveLineFlowmappingEntry 6 }
inactiveLineFlowmappingType OBJECT-TYPE
SYNTAX INTEGER(0..3)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineFlowmappingType:
0 flowmapping not base port.
1 flowmapping base eth port.
2 flowmapping base veip port.
3. flowmapping base iphost port."
::= { inactiveLineFlowmappingEntry 7 }
inactiveLineFlowmappingRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveLineFlowmappingEntry 8 }
-- 1.1.2.3.5. inactiveLineAttrMgmtTable --------------------
inactiveLineAttrMgmtTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveLineAttrMgmtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain line attribute management table."
::= { inactiveLineCommonConfig 5 }
inactiveLineAttrMgmtEntry OBJECT-TYPE
SYNTAX InactiveLineAttrMgmtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive line attribute management table"
INDEX { inactiveLineIndexIV, inactiveLineAttrMgmtIndex }
::= { inactiveLineAttrMgmtTable 1 }
InactiveLineAttrMgmtEntry ::=
SEQUENCE
{
inactiveLineIndexIV INTEGER,
inactiveLineAttrMgmtIndex INTEGER,
inactiveLineAttrMgmtNportType INTEGER,
inactiveLineAttrMgmtNport INTEGER,
inactiveLineAttrMgmtEtypeFilter INTEGER,
inactiveLineAttrMgmtVlanMode INTEGER,
inactiveLineAttrMgmtCvlanVid INTEGER,
inactiveLineAttrMgmtCvlanPri INTEGER,
inactiveLineAttrMgmtSvlanVid INTEGER,
inactiveLineAttrMgmtSvlanPri INTEGER,
inactiveLineAttrMgmtRowStatus RowStatus
}
inactiveLineIndexIV OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 1st index of this table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveLineAttrMgmtEntry 1 }
inactiveLineAttrMgmtIndex OBJECT-TYPE
SYNTAX INTEGER(0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of attribute management, the 2nd index of this table. Should in <1-64>."
::= { inactiveLineAttrMgmtEntry 2 }
inactiveLineAttrMgmtNportType OBJECT-TYPE
SYNTAX INTEGER(1..3)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineAttrMgmtNportType:
1 eth port in sfu
2 veip port in hgu
3 iphost virtual port, for voip, tdm, etc."
::= { inactiveLineAttrMgmtEntry 3 }
inactiveLineAttrMgmtNport OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port of attribute management, if eport, should in <1-8>."
::= { inactiveLineAttrMgmtEntry 4 }
inactiveLineAttrMgmtEtypeFilter OBJECT-TYPE
SYNTAX INTEGER(0..3)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineAttrMgmtEtypeFilter:
0 no filter
1 filter ipoe frame
2 filter pppoe frame
3 filter arp frame"
::= { inactiveLineAttrMgmtEntry 5 }
inactiveLineAttrMgmtVlanMode OBJECT-TYPE
SYNTAX INTEGER(0..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineAttrMgmtVlanMode:
0 transparent
1 tag
2 translation
3 trunk
4 QinQ"
::= { inactiveLineAttrMgmtEntry 6 }
inactiveLineAttrMgmtCvlanVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"cvlan vid, should be inputted with <1-4094>."
::= { inactiveLineAttrMgmtEntry 7 }
inactiveLineAttrMgmtCvlanPri OBJECT-TYPE
SYNTAX INTEGER(0..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The cvlan priority, should be inputted with <0-8>.
Value 8 means don't care vlan priority."
::= { inactiveLineAttrMgmtEntry 8 }
inactiveLineAttrMgmtSvlanVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"svlan vid, should be inputted with <1-4094>."
::= { inactiveLineAttrMgmtEntry 9 }
inactiveLineAttrMgmtSvlanPri OBJECT-TYPE
SYNTAX INTEGER(0..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"svlan priority, should be inputted with <0-8>.
Value 8 means don't care vlan priority."
::= { inactiveLineAttrMgmtEntry 10 }
inactiveLineAttrMgmtRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveLineAttrMgmtEntry 11 }
-- 1.1.2.3.6. inactiveLineCportTable --------------------
inactiveLineCportTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveLineCportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain line catv port management table."
::= { inactiveLineCommonConfig 6 }
inactiveLineCportEntry OBJECT-TYPE
SYNTAX InactiveLineCportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive line catv port management table"
INDEX { inactiveLineIndexX, inactiveLineCportIndex }
::= { inactiveLineCportTable 1 }
InactiveLineCportEntry ::=
SEQUENCE
{
inactiveLineIndexX INTEGER,
inactiveLineCportIndex INTEGER,
inactiveLineCportSwitch INTEGER,
inactiveLineCportAgcMode INTEGER,
inactiveLineCportAgcRange INTEGER
}
inactiveLineIndexX OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 1st index of this table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveLineCportEntry 1 }
inactiveLineCportIndex OBJECT-TYPE
SYNTAX INTEGER(1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of catv port management, the 2nd index of this table. Should in <1-4>."
::= { inactiveLineCportEntry 2 }
inactiveLineCportSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineCportSwitch:
0 disable
1 enable(default)"
::= { inactiveLineCportEntry 3 }
inactiveLineCportAgcMode OBJECT-TYPE
SYNTAX INTEGER(0..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineCportAgcMode:
0 No AGC
1 Broadband RF AGC
2 Optical AGC"
::= { inactiveLineCportEntry 4 }
inactiveLineCportAgcRange OBJECT-TYPE
SYNTAX INTEGER(-120..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"catv port agc range, default: 0."
::= { inactiveLineCportEntry 5 }
-- 1.1.2.3.7. inactiveLineAlarmRefTable --------------------
inactiveLineAlarmRefTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveLineAlarmRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive line alarm Reference table."
::= { inactiveLineCommonConfig 7 }
inactiveLineAlarmRefEntry OBJECT-TYPE
SYNTAX InactiveLineAlarmRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive line alarm Reference table"
INDEX { inactiveLineAlarmRefLIndex }
::= { inactiveLineAlarmRefTable 1 }
InactiveLineAlarmRefEntry ::=
SEQUENCE
{
inactiveLineAlarmRefLIndex INTEGER,
inactiveLineAlarmRefAIndex INTEGER,
inactiveLineAlarmRefAName OCTET STRING,
inactiveLineAlarmRefRowStatus RowStatus
}
inactiveLineAlarmRefLIndex OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The line index of this table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveLineAlarmRefEntry 1 }
inactiveLineAlarmRefAIndex OBJECT-TYPE
SYNTAX INTEGER(0..127)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The index of alarm table to reference, Should in <0-127>."
::= { inactiveLineAlarmRefEntry 2 }
inactiveLineAlarmRefAName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..128))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entry name of alarm table to reference, Should in <1-128>."
::= { inactiveLineAlarmRefEntry 3 }
inactiveLineAlarmRefRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of inactive line alarm Reference table."
::= { inactiveLineAlarmRefEntry 4 }
-- 1.1.2.4. inactiveLineSFUConfig --------------------------
inactiveLineSFUConfig OBJECT IDENTIFIER ::= { deployInactive 4 }
-- 1.1.2.4.1. inactiveLineSFUTable
-- 1.1.2.4.2. inactiveLineSFUEthportTable
-- 1.1.2.4.1. inactiveLineSFUTable ------------------------
inactiveLineSFUTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveLineSFUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain line SFU primary table."
::= { inactiveLineSFUConfig 1 }
inactiveLineSFUEntry OBJECT-TYPE
SYNTAX InactiveLineSFUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive line sfu primary table"
INDEX { inactiveLineIndexV }
::= { inactiveLineSFUTable 1 }
InactiveLineSFUEntry ::=
SEQUENCE
{
inactiveLineIndexV INTEGER,
inactiveLineSfuLocalSwitch INTEGER,
inactiveLineSfuLoopDetectSwitch INTEGER
}
inactiveLineIndexV OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 1st index of this table, should be inputted with <0-4095>.
The range is not always fit, please see range in commands."
::= { inactiveLineSFUEntry 1 }
inactiveLineSfuLocalSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineSfuLocalSwitch:
0 disable(default)
1 enable."
::= { inactiveLineSFUEntry 2 }
inactiveLineSfuLoopDetectSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineSfuLoopDetectSwitch:
0 disable(default)
1 enable."
::= { inactiveLineSFUEntry 3 }
-- 1.1.2.4.2. inactiveLineSFUEthportTable ------------------
inactiveLineSFUEthportTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveLineSFUEthportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain line SFU ethernet port table."
::= { inactiveLineSFUConfig 2 }
inactiveLineSFUEthportEntry OBJECT-TYPE
SYNTAX InactiveLineSFUEthportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive line SFU ethernet port table"
INDEX { inactiveLineIndexVI, inactiveLineSfuEthportIndex }
::= { inactiveLineSFUEthportTable 1 }
InactiveLineSFUEthportEntry ::=
SEQUENCE
{
inactiveLineIndexVI INTEGER,
inactiveLineSfuEthportIndex INTEGER,
inactiveLineSfuEthportSwitch INTEGER,
inactiveLineSfuEthportFlowCtrlSwitch INTEGER,
inactiveLineSfuEthportLoopbackSwitch INTEGER,
inactiveLineSfuEthportFastLeaveSwitch INTEGER,
inactiveLineSfuEthportMaxGroups INTEGER,
inactiveLineSfuEthportMaxMacCount INTEGER,
inactiveLineSfuEthportMcastMode INTEGER,
inactiveLineSfuEthportDsIgmpControlType INTEGER,
inactiveLineSfuEthportDsIgmpVid INTEGER,
inactiveLineSfuEthportDsIgmpPri INTEGER,
inactiveLineSfuEthportDsIgmpRowStatus RowStatus,
inactiveLineSfuEthportUsIgmpControlType INTEGER,
inactiveLineSfuEthportUsIgmpVid INTEGER,
inactiveLineSfuEthportUsIgmpPri INTEGER,
inactiveLineSfuEthportUsIgmpRowStatus RowStatus,
inactiveLineSfuEthportBwCir INTEGER,
inactiveLineSfuEthportBwCbs INTEGER,
inactiveLineSfuEthportBwPir INTEGER,
inactiveLineSfuEthportBwPbs INTEGER,
inactiveLineSfuEthportBwRowStatus RowStatus
}
inactiveLineIndexVI OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 1st index of this table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveLineSFUEthportEntry 1 }
inactiveLineSfuEthportIndex OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of SFU ethernet port, the 2nd index of this table. Should in <1-8>."
::= { inactiveLineSFUEthportEntry 2 }
inactiveLineSfuEthportSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineSfuEthportSwitch:
0 no shutdown(default)
1 shutdown"
::= { inactiveLineSFUEthportEntry 3 }
inactiveLineSfuEthportFlowCtrlSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineSfuEthportFlowCtrlSwitch:
0 disable(default)
1 enable"
::= { inactiveLineSFUEthportEntry 4 }
inactiveLineSfuEthportLoopbackSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineSfuEthportLoopbackSwitch:
0 disable(default)
1 enable"
::= { inactiveLineSFUEthportEntry 5 }
inactiveLineSfuEthportFastLeaveSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineSfuEthportFastLeaveSwitch:
0 disable(default)
1 enable"
::= { inactiveLineSFUEthportEntry 6 }
inactiveLineSfuEthportMaxGroups OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SFU ethernet port max igmp groups, should be inputted with <1-128>."
::= { inactiveLineSFUEthportEntry 7 }
inactiveLineSfuEthportMaxMacCount OBJECT-TYPE
SYNTAX INTEGER(1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SFU ethernet port max mac address count, should be inputted with <1-255>."
::= { inactiveLineSFUEthportEntry 8 }
inactiveLineSfuEthportMcastMode OBJECT-TYPE
SYNTAX INTEGER(0..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineSfuEthportMcastMode(some ont not support):
0 control
1 igmp snooping
2 unconcern(default)"
::= { inactiveLineSFUEthportEntry 9 }
inactiveLineSfuEthportDsIgmpControlType OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineSfuEthportDsIgmpControlType:
0 transparent(default, only for read)
1 strip outer tag
2 add tag
3 replace tag
4 replace only vid
5 add only vid"
::= { inactiveLineSFUEthportEntry 10 }
inactiveLineSfuEthportDsIgmpVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SFU ethernet port downstream igmp and multicast control vid,
should be inputted with <1-4094>."
::= { inactiveLineSFUEthportEntry 11 }
inactiveLineSfuEthportDsIgmpPri OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The vlan priority, should be inputted with <0-7>."
::= { inactiveLineSFUEthportEntry 12 }
inactiveLineSfuEthportDsIgmpRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus for ethport ds igmp tag control."
::= { inactiveLineSFUEthportEntry 13 }
inactiveLineSfuEthportUsIgmpControlType OBJECT-TYPE
SYNTAX INTEGER(0..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineSfuEthportUsIgmpControlType:
0 transparent(default, only for read)
1 add tag
2 replace tag
3 replace only vid
4 add only vid"
::= { inactiveLineSFUEthportEntry 14 }
inactiveLineSfuEthportUsIgmpVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SFU ethernet port upstream igmp and multicast control vid,
should be inputted with <1-4094>."
::= { inactiveLineSFUEthportEntry 15 }
inactiveLineSfuEthportUsIgmpPri OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The vlan priority, should be inputted with <0-7>."
::= { inactiveLineSFUEthportEntry 16 }
inactiveLineSfuEthportUsIgmpRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus for ethport us igmp tag control."
::= { inactiveLineSFUEthportEntry 17 }
inactiveLineSfuEthportBwCir OBJECT-TYPE
SYNTAX INTEGER(64..1024000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SFU ethernet port bandwidth egress cir, should be inputted with <64-1024000>."
::= { inactiveLineSFUEthportEntry 18 }
inactiveLineSfuEthportBwCbs OBJECT-TYPE
SYNTAX INTEGER(2..32000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SFU ethernet port bandwidth egress cbs, should be inputted with <2-32000>."
::= { inactiveLineSFUEthportEntry 19 }
inactiveLineSfuEthportBwPir OBJECT-TYPE
SYNTAX INTEGER(64..1024000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SFU ethernet port bandwidth egress pir, should be inputted with <64-1024000>."
::= { inactiveLineSFUEthportEntry 20 }
inactiveLineSfuEthportBwPbs OBJECT-TYPE
SYNTAX INTEGER(2..32000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SFU ethernet port bandwidth egress pbs, should be inputted with <2-32000>."
::= { inactiveLineSFUEthportEntry 21 }
inactiveLineSfuEthportBwRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus for ethernet port bandwidth egress."
::= { inactiveLineSFUEthportEntry 22 }
-- 1.1.2.5. inactiveLineHGUConfig --------------------------
inactiveLineHGUConfig OBJECT IDENTIFIER ::= { deployInactive 5 }
-- 1.1.2.5.1. inactiveLineHGUTable
-- 1.1.2.5.1. inactiveLineHGUTable ------------------------
inactiveLineHGUTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveLineHGUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain line HGU table."
::= { inactiveLineHGUConfig 1 }
inactiveLineHGUEntry OBJECT-TYPE
SYNTAX InactiveLineHGUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive line HGU table"
INDEX { inactiveLineIndexVIII }
::= { inactiveLineHGUTable 1 }
InactiveLineHGUEntry ::=
SEQUENCE
{
inactiveLineIndexVIII INTEGER,
inactiveLineHguSwitch INTEGER,
inactiveLineHguFastLeaveSwitch INTEGER,
inactiveLineHguMaxGroups INTEGER,
inactiveLineHguMaxMacCount INTEGER,
inactiveLineHguMcastMode INTEGER,
inactiveLineHguDsIgmpControlType INTEGER,
inactiveLineHguDsIgmpVid INTEGER,
inactiveLineHguDsIgmpPri INTEGER,
inactiveLineHguDsIgmpRowStatus RowStatus,
inactiveLineHguUsIgmpControlType INTEGER,
inactiveLineHguUsIgmpVid INTEGER,
inactiveLineHguUsIgmpPri INTEGER,
inactiveLineHguUsIgmpRowStatus RowStatus,
inactiveLineHguMcastEportSwitch INTEGER
}
inactiveLineIndexVIII OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 1st index of this table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveLineHGUEntry 1 }
inactiveLineHguSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineHguSwitch:
0 no shutdown(default)
1 shutdown"
::= { inactiveLineHGUEntry 2 }
inactiveLineHguFastLeaveSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineHguFlowCtrlSwitch:
0 disable(default)
1 enable"
::= { inactiveLineHGUEntry 3 }
inactiveLineHguMaxGroups OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The HGU max igmp groups, should be inputted with <1-128>."
::= { inactiveLineHGUEntry 4 }
inactiveLineHguMaxMacCount OBJECT-TYPE
SYNTAX INTEGER(1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The HGU max mac address count, should be inputted with <1-255>."
::= { inactiveLineHGUEntry 5 }
inactiveLineHguMcastMode OBJECT-TYPE
SYNTAX INTEGER(0..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineHguMcastMode(some ont not support):
0 control
1 igmp snooping
2 unconcern(default)"
::= { inactiveLineHGUEntry 6 }
inactiveLineHguDsIgmpControlType OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineHguDsIgmpControlType:
0 transparent(default)
1 strip outer tag
2 add tag
3 replace tag
4 replace only vid
5 add only vid"
::= { inactiveLineHGUEntry 7 }
inactiveLineHguDsIgmpVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The HGU downstream igmp and multicast control vid,
should be inputted with <1-4094>."
::= { inactiveLineHGUEntry 8 }
inactiveLineHguDsIgmpPri OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The vlan priority, should be inputted with <0-7>."
::= { inactiveLineHGUEntry 9 }
inactiveLineHguDsIgmpRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus for ds igmp tag control."
::= { inactiveLineHGUEntry 10 }
inactiveLineHguUsIgmpControlType OBJECT-TYPE
SYNTAX INTEGER(0..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineHguUsIgmpControlType:
0 transparent(default)
1 add tag
2 replace tag
3 replace only vid
4 add only vid"
::= { inactiveLineHGUEntry 11 }
inactiveLineHguUsIgmpVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The HGU upstream igmp and multicast control vid,
should be inputted with <1-4094>."
::= { inactiveLineHGUEntry 12 }
inactiveLineHguUsIgmpPri OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The vlan priority, should be inputted with <0-7>."
::= { inactiveLineHGUEntry 13 }
inactiveLineHguUsIgmpRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus for us igmp tag control."
::= { inactiveLineHGUEntry 14 }
inactiveLineHguMcastEportSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveLineHguMcastEportSwitch:
0 disable Hgu ctrl mcast base on eport(default)
1 enable Hgu ctrl mcast base on eport"
::= { inactiveLineHGUEntry 15 }
-- 1.1.2.6. inactiveRuleTable ------------------------------
inactiveRuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveRuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain rule table"
::= { deployInactive 6 }
inactiveRuleEntry OBJECT-TYPE
SYNTAX InactiveRuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive rule table"
INDEX { inactiveRuleIndex }
::= { inactiveRuleTable 1 }
InactiveRuleEntry ::=
SEQUENCE
{
inactiveRuleIndex INTEGER,
inactiveRuleName OCTET STRING,
inactiveRuleAction INTEGER,
inactiveRuleAuthMode INTEGER,
inactiveRuleAuthSn OCTET STRING,
inactiveRuleAuthPw OCTET STRING,
inactiveRuleAuthLoid OCTET STRING,
inactiveRuleAuthLopw OCTET STRING,
inactiveRuleAssignedSlot OCTET STRING,
inactiveRuleAssignedPport OCTET STRING,
inactiveRuleAssignedOnt OCTET STRING,
inactiveRuleLineIndexesStr OCTET STRING,
inactiveRuleDefaultLine INTEGER,
inactiveRuleRowStatus RowStatus,
inactiveRuleOnceOnSwitch INTEGER,
inactiveRuleOnceOnAgingTime INTEGER,
inactiveRuleAuthSnFmt INTEGER,
inactiveRuleAuthPwFmt INTEGER,
inactiveRuleOntStatus INTEGER
}
inactiveRuleIndex OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of rule table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveRuleEntry 1 }
inactiveRuleName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"rule description, max length: 128."
::= { inactiveRuleEntry 2 }
inactiveRuleAction OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveRuleAction:
0 permit
1 deny"
::= { inactiveRuleEntry 3 }
inactiveRuleAuthMode OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveRuleAuthMode:
0 auth mode sn
1 auth mode pw
2 auth mode sn_pw
3 auth mode loid
4 auth mode lopw
5 auth mode loid_lopw"
::= { inactiveRuleEntry 4 }
inactiveRuleAuthSn OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(13..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"auth sn, mix(string-hex) format or hex format.
length:
mix: 13
hex: 16
you can use '*' represents any one character or hexadecimal number."
::= { inactiveRuleEntry 5 }
inactiveRuleAuthPw OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"auth password, string format or hex format.
max length:
string: 10
hex: 20
you can use '*' represents any one character or hexadecimal number"
::= { inactiveRuleEntry 6 }
inactiveRuleAuthLoid OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"auth loid, string format, max length: 24.
you can use '*' represents any one character or hexadecimal number"
::= { inactiveRuleEntry 7 }
inactiveRuleAuthLopw OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"auth logic password, string format, max length: 12.
you can use '*' represents any one character or hexadecimal number"
::= { inactiveRuleEntry 8 }
inactiveRuleAssignedSlot OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"slot id pre assigned. if not configed, its '-'."
::= { inactiveRuleEntry 9 }
inactiveRuleAssignedPport OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"pon port id pre assigned. if not configed, its '-'."
::= { inactiveRuleEntry 10 }
inactiveRuleAssignedOnt OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ont id pre assigned. if not configed, its '-'."
::= { inactiveRuleEntry 11 }
inactiveRuleLineIndexesStr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"String joined by rule bind line indexes, such as '12,56,1023'.
A rule can at most bind 8 line models."
::= { inactiveRuleEntry 12 }
inactiveRuleDefaultLine OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The index of rule default line, should be inputted with <1-4096>
The range is not always fit, please see range in commands."
::= { inactiveRuleEntry 13 }
inactiveRuleRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveRuleEntry 14 }
inactiveRuleOnceOnSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveUniqueOnceOnSwitch:
0 always on(default)
1 once on."
::= { inactiveRuleEntry 15 }
inactiveRuleOnceOnAgingTime OBJECT-TYPE
SYNTAX INTEGER(0..168)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"aging time, hour, default value 0, means don't care aging time."
::= { inactiveRuleEntry 16 }
inactiveRuleAuthSnFmt OBJECT-TYPE
SYNTAX INTEGER {
mix(0),
hex(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Serial number format, mixed or hexadecimal."
::= { inactiveRuleEntry 17 }
inactiveRuleAuthPwFmt OBJECT-TYPE
SYNTAX INTEGER {
string(0),
hex(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Password format, string or hexadecimal."
::= { inactiveRuleEntry 18 }
inactiveRuleOntStatus OBJECT-TYPE
SYNTAX INTEGER {
Unused(0),
Inused(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ont status.
0: Ont has never been online
1: Ont online or offline"
::= { inactiveRuleEntry 19 }
-- 1.1.2.7. inactiveUniqueConfig --------------------------
inactiveUniqueConfig OBJECT IDENTIFIER ::= { deployInactive 7 }
-- 1.1.2.7.1. inactiveUniquePrimaryTable
-- 1.1.2.7.2. inactiveUniqueSipAgentInfoTable
-- 1.1.2.7.3. inactiveUniqueSipUserAddrTable
-- 1.1.2.7.4. inactiveUniqueSipUserInfoTable
-- 1.1.2.7.5. inactiveUniqueSipDigitMapTable
-- 1.1.2.7.6. inactiveUniqueGemportTable
-- 1.1.2.7.7. inactiveUniqueCportTable
-- 1.1.2.7.8. inactiveUniqueEportTable
-- 1.1.2.7.9. inactiveUniqueTcontTable
-- 1.1.2.7.10. inactiveUniqueAlarmRefTable
-- 1.1.2.7.11. inactiveUniqueManageTable
-- 1.1.2.7.12. inactiveUniqueWanTable
-- 1.1.2.7.1. inactiveUniquePrimaryTable ------------------
inactiveUniquePrimaryTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveUniquePrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain unique primary table"
::= { inactiveUniqueConfig 1 }
inactiveUniquePrimaryEntry OBJECT-TYPE
SYNTAX InactiveUniquePrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive unique primary table"
INDEX { inactiveUniqueIndex }
::= { inactiveUniquePrimaryTable 1 }
InactiveUniquePrimaryEntry ::=
SEQUENCE
{
inactiveUniqueIndex INTEGER,
inactiveUniqueName OCTET STRING,
inactiveUniqueSignFlag INTEGER,
inactiveUniqueSn OCTET STRING,
inactiveUniqueLoid OCTET STRING,
inactiveUniqueSlotId INTEGER,
inactiveUniquePportId INTEGER,
inactiveUniqueOntId INTEGER,
inactiveUniqueOntDesc OCTET STRING,
inactiveUniqueRowStatus RowStatus,
inactiveUniqueOnceOnSwitch INTEGER,
inactiveUniqueOnceOnAgingTime INTEGER,
inactiveUniqueRangingBalance INTEGER
}
inactiveUniqueIndex OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of unique primary table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveUniquePrimaryEntry 1 }
inactiveUniqueName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"unique name, max length: 128."
::= { inactiveUniquePrimaryEntry 2 }
inactiveUniqueSignFlag OBJECT-TYPE
SYNTAX INTEGER(1..3)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveUniqueSignFlag:
1 mode sn
2 mode loid
3 mode slot-id/pport-id/ont-id."
::= { inactiveUniquePrimaryEntry 3 }
inactiveUniqueSn OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"unique sn, now only support string-hex format, not support hex format, max length: 13."
::= { inactiveUniquePrimaryEntry 4 }
inactiveUniqueLoid OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"unique loid, now only support string format, max length: 24."
::= { inactiveUniquePrimaryEntry 5 }
inactiveUniqueSlotId OBJECT-TYPE
SYNTAX INTEGER(0..0)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"slot id."
::= { inactiveUniquePrimaryEntry 6 }
inactiveUniquePportId OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"pon port id."
::= { inactiveUniquePrimaryEntry 7 }
inactiveUniqueOntId OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ont id."
::= { inactiveUniquePrimaryEntry 8 }
inactiveUniqueOntDesc OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ont description, max length: 128."
::= { inactiveUniquePrimaryEntry 9 }
inactiveUniqueRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveUniquePrimaryEntry 10 }
inactiveUniqueOnceOnSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveUniqueOnceOnSwitch:
0 always on(default)
1 once on."
::= { inactiveUniquePrimaryEntry 11 }
inactiveUniqueOnceOnAgingTime OBJECT-TYPE
SYNTAX INTEGER(0..168)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"aging time, default value 0, means don't care aging time."
::= { inactiveUniquePrimaryEntry 12 }
inactiveUniqueRangingBalance OBJECT-TYPE
SYNTAX INTEGER(-10000..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ranging balance, default value 0, unit: m."
::= { inactiveUniquePrimaryEntry 13 }
-- 1.1.2.7.2. inactiveUniqueSipAgentInfoTable --------------
inactiveUniqueSipAgentInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveUniqueSipAgentInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain unique voip sip agent info table"
::= { inactiveUniqueConfig 2 }
inactiveUniqueSipAgentInfoEntry OBJECT-TYPE
SYNTAX InactiveUniqueSipAgentInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive unique voip sip agent info table"
INDEX { inactiveUniqueIndexI }
::= { inactiveUniqueSipAgentInfoTable 1 }
InactiveUniqueSipAgentInfoEntry ::=
SEQUENCE
{
inactiveUniqueIndexI INTEGER,
inactiveUniqueSipProxyServerIp OCTET STRING,
inactiveUniqueSipOutboundProxyIp OCTET STRING,
inactiveUniqueSipRegisterServerIp OCTET STRING,
inactiveUniqueSipAgentInfoPort INTEGER,
inactiveUniqueSipAgentInfoRowStatus RowStatus
}
inactiveUniqueIndexI OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of unique primary table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveUniqueSipAgentInfoEntry 1 }
inactiveUniqueSipProxyServerIp OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"voip sip agent info proxy server ip address."
::= { inactiveUniqueSipAgentInfoEntry 2 }
inactiveUniqueSipOutboundProxyIp OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"voip sip agent info outbound proxy ip address."
::= { inactiveUniqueSipAgentInfoEntry 3 }
inactiveUniqueSipRegisterServerIp OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"voip sip agent info register server ip address."
::= { inactiveUniqueSipAgentInfoEntry 4 }
inactiveUniqueSipAgentInfoPort OBJECT-TYPE
SYNTAX INTEGER(1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"voip sip agent info port."
::= { inactiveUniqueSipAgentInfoEntry 5 }
inactiveUniqueSipAgentInfoRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveUniqueSipAgentInfoEntry 6 }
-- 1.1.2.7.3. inactiveUniqueSipUserAddrTable --------------
inactiveUniqueSipUserAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveUniqueSipUserAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain unique voip sip user ip address table"
::= { inactiveUniqueConfig 3 }
inactiveUniqueSipUserAddrEntry OBJECT-TYPE
SYNTAX InactiveUniqueSipUserAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive unique voip sip user ip address table"
INDEX { inactiveUniqueIndexII }
::= { inactiveUniqueSipUserAddrTable 1 }
InactiveUniqueSipUserAddrEntry ::=
SEQUENCE
{
inactiveUniqueIndexII INTEGER,
inactiveUniqueSipuAddressIp IpAddress,
inactiveUniqueSipuAddressMask IpAddress,
inactiveUniqueSipuAddressVlan INTEGER,
inactiveUniqueSipuAddressPri INTEGER,
inactiveUniqueSipuAddressRowStatus RowStatus,
inactiveUniqueSipuAddressGateway IpAddress,
inactiveUniqueSipuAddressMasterDns IpAddress,
inactiveUniqueSipuAddressSlaveDns IpAddress,
inactiveUniqueSipuAddressHost INTEGER,
inactiveUniqueSipuAddressMode INTEGER
}
inactiveUniqueIndexII OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of unique primary table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveUniqueSipUserAddrEntry 1 }
inactiveUniqueSipuAddressIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"voip sip user ip address."
::= { inactiveUniqueSipUserAddrEntry 2 }
inactiveUniqueSipuAddressMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"voip sip user mask."
::= { inactiveUniqueSipUserAddrEntry 3 }
inactiveUniqueSipuAddressVlan OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"voip sip user vlan."
::= { inactiveUniqueSipUserAddrEntry 4 }
inactiveUniqueSipuAddressPri OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"voip sip user priroty."
::= { inactiveUniqueSipUserAddrEntry 5 }
inactiveUniqueSipuAddressRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveUniqueSipUserAddrEntry 6 }
inactiveUniqueSipuAddressGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"voip sip user gateway."
::= { inactiveUniqueSipUserAddrEntry 7 }
inactiveUniqueSipuAddressMasterDns OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"voip sip user master DNS."
::= { inactiveUniqueSipUserAddrEntry 8 }
inactiveUniqueSipuAddressSlaveDns OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"voip sip user slave DNS."
::= { inactiveUniqueSipUserAddrEntry 9 }
inactiveUniqueSipuAddressHost OBJECT-TYPE
SYNTAX INTEGER(1..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"voip sip user host."
::= { inactiveUniqueSipUserAddrEntry 10 }
inactiveUniqueSipuAddressMode OBJECT-TYPE
SYNTAX INTEGER {
static(0),
dhcp(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"voip sip user mode.
0(default): static ip mode;
1: dhcp mode."
::= { inactiveUniqueSipUserAddrEntry 11 }
-- 1.1.2.7.4. inactiveUniqueSipUserInfoTable --------------
inactiveUniqueSipUserInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveUniqueSipUserInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain unique voip sip user infomation table"
::= { inactiveUniqueConfig 4 }
inactiveUniqueSipUserInfoEntry OBJECT-TYPE
SYNTAX InactiveUniqueSipUserInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of unique voip sip user infomation table"
INDEX { inactiveUniqueIndexIII, inactiveUniqueSipuInfoIndex }
::= { inactiveUniqueSipUserInfoTable 1 }
InactiveUniqueSipUserInfoEntry ::=
SEQUENCE
{
inactiveUniqueIndexIII INTEGER,
inactiveUniqueSipuInfoIndex INTEGER,
inactiveUniqueSipuInfoUserName OCTET STRING,
inactiveUniqueSipuInfoPassword OCTET STRING,
inactiveUniqueSipuInfoTelephone OCTET STRING,
inactiveUniqueSipuInfoRowStatus RowStatus
}
inactiveUniqueIndexIII OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of unique primary table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveUniqueSipUserInfoEntry 1 }
inactiveUniqueSipuInfoIndex OBJECT-TYPE
SYNTAX INTEGER(1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of voip sip user info, the 2nd index of this table. Should in <1-2>."
::= { inactiveUniqueSipUserInfoEntry 2 }
inactiveUniqueSipuInfoUserName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..25))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"voip sip user infomation user name, max length: 25."
::= { inactiveUniqueSipUserInfoEntry 3 }
inactiveUniqueSipuInfoPassword OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..25))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"voip sip user infomation user name, max length: 25."
::= { inactiveUniqueSipUserInfoEntry 4 }
inactiveUniqueSipuInfoTelephone OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..25))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"voip sip user infomation user name, max length: 25."
::= { inactiveUniqueSipUserInfoEntry 5 }
inactiveUniqueSipuInfoRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveUniqueSipUserInfoEntry 6 }
-- 1.1.2.7.5. inactiveUniqueSipDigitMapTable --------------
inactiveUniqueSipDigitMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveUniqueSipDigitMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain unique voip sip digit map table"
::= { inactiveUniqueConfig 5 }
inactiveUniqueSipDigitMapEntry OBJECT-TYPE
SYNTAX InactiveUniqueSipDigitMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive unique voip sip digit map table"
INDEX { inactiveUniqueIndexIV, inactiveUniqueSipdMapIndex }
::= { inactiveUniqueSipDigitMapTable 1 }
InactiveUniqueSipDigitMapEntry ::=
SEQUENCE
{
inactiveUniqueIndexIV INTEGER,
inactiveUniqueSipdMapIndex INTEGER,
inactiveUniqueSipdMapDialPlanToken OCTET STRING,
inactiveUniqueSipdMapRowStatus RowStatus
}
inactiveUniqueIndexIV OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of unique primary table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveUniqueSipDigitMapEntry 1 }
inactiveUniqueSipdMapIndex OBJECT-TYPE
SYNTAX INTEGER(1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of voip digit map, the 2nd index of this table. Should in <1-10>."
::= { inactiveUniqueSipDigitMapEntry 2 }
inactiveUniqueSipdMapDialPlanToken OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..28))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"voip sip digit map dial plan token, max length: 28."
::= { inactiveUniqueSipDigitMapEntry 3 }
inactiveUniqueSipdMapRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveUniqueSipDigitMapEntry 4 }
-- 1.1.2.7.6. inactiveUniqueGemportTable --------------------
inactiveUniqueGemportTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveUniqueGemportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain unique gemport table."
::= { inactiveUniqueConfig 6 }
inactiveUniqueGemportEntry OBJECT-TYPE
SYNTAX InactiveUniqueGemportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive unique gemport table"
INDEX { inactiveUniqueIndexV, inactiveUniqueGemportIndex }
::= { inactiveUniqueGemportTable 1 }
InactiveUniqueGemportEntry ::=
SEQUENCE
{
inactiveUniqueIndexV INTEGER,
inactiveUniqueGemportIndex INTEGER,
inactiveUniqueGemportVlanProfileId INTEGER,
inactiveUniqueGemportUsProfileId INTEGER,
inactiveUniqueGemportDsProfileId INTEGER,
inactiveUniqueGemportRowStatus RowStatus
}
inactiveUniqueIndexV OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 1st index of this table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveUniqueGemportEntry 1 }
inactiveUniqueGemportIndex OBJECT-TYPE
SYNTAX INTEGER(1..24)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of gemport, the 2nd index of this table.
Should in <1-24>."
::= { inactiveUniqueGemportEntry 2 }
inactiveUniqueGemportVlanProfileId OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gemport vlan profile id, should be inputted with <0-4095>."
::= { inactiveUniqueGemportEntry 3 }
inactiveUniqueGemportUsProfileId OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gemport us traffic profile id, should be inputted with <0-4095>."
::= { inactiveUniqueGemportEntry 4 }
inactiveUniqueGemportDsProfileId OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gemport ds traffic profile id, should be inputted with <0-4095>."
::= { inactiveUniqueGemportEntry 5 }
inactiveUniqueGemportRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveUniqueGemportEntry 6 }
-- 1.1.2.7.7. inactiveUniqueCportTable --------------------
inactiveUniqueCportTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveUniqueCportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain unique catv port management table."
::= { inactiveUniqueConfig 7 }
inactiveUniqueCportEntry OBJECT-TYPE
SYNTAX InactiveUniqueCportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive unique catv port management table"
INDEX { inactiveUniqueIndexVI, inactiveUniqueCportIndex }
::= { inactiveUniqueCportTable 1 }
InactiveUniqueCportEntry ::=
SEQUENCE
{
inactiveUniqueIndexVI INTEGER,
inactiveUniqueCportIndex INTEGER,
inactiveUniqueCportSwitch INTEGER,
inactiveUniqueCportAgcMode INTEGER,
inactiveUniqueCportAgcRange INTEGER
}
inactiveUniqueIndexVI OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 1st index of this table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveUniqueCportEntry 1 }
inactiveUniqueCportIndex OBJECT-TYPE
SYNTAX INTEGER(1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of catv port management, the 2nd index of this table. Should in <1-4>."
::= { inactiveUniqueCportEntry 2 }
inactiveUniqueCportSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveUniqueCportSwitch:
0 disable
1 enable(default)"
::= { inactiveUniqueCportEntry 3 }
inactiveUniqueCportAgcMode OBJECT-TYPE
SYNTAX INTEGER(0..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveUniqueCportAgcMode:
0 No AGC
1 Broadband RF AGC
2 Optical AGC"
::= { inactiveUniqueCportEntry 4 }
inactiveUniqueCportAgcRange OBJECT-TYPE
SYNTAX INTEGER(-120..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"catv port agc range, default: 0."
::= { inactiveUniqueCportEntry 5 }
-- 1.1.2.7.8. inactiveUniqueEportTable --------------------
inactiveUniqueEportTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveUniqueEportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain unique ethernet port management table."
::= { inactiveUniqueConfig 8 }
inactiveUniqueEportEntry OBJECT-TYPE
SYNTAX InactiveUniqueEportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive unique ethernet port management table"
INDEX { inactiveUniqueIndexVII, inactiveUniqueEportIndex }
::= { inactiveUniqueEportTable 1 }
InactiveUniqueEportEntry ::=
SEQUENCE
{
inactiveUniqueIndexVII INTEGER,
inactiveUniqueEportIndex INTEGER,
inactiveUniqueEportSwitch INTEGER,
inactiveUniqueEportNegMode INTEGER
}
inactiveUniqueIndexVII OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 1st index of this table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveUniqueEportEntry 1 }
inactiveUniqueEportIndex OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ethernet port management, the 2nd index of this table. Should in <1-8>."
::= { inactiveUniqueEportEntry 2 }
inactiveUniqueEportSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveUniqueEportSwitch:
0 enable(default)
1 disable"
::= { inactiveUniqueEportEntry 3 }
-- <20><>ʱ<EFBFBD><CAB1>δʵ<CEB4><CAB5>
inactiveUniqueEportNegMode OBJECT-TYPE
SYNTAX INTEGER(0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"neg mode contains duplex and speed.
duplex: 0 auto, 1 full, 2 half
speed: 0 auto, 1 10M, 2 100M, 3 1000M
neg mode = duplex * 10 + speed.
neg mode value 0 means auto duplex auto speed,
value 11 means full duplex 10M, and so on."
-- ģʽ<C4A3><CABD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>Ҫͬʱ<CDAC><EFBFBD><E4A3AC><EFBFBD><EFBFBD><EFBFBD>ñȽ<C3B1><C8BD><EFBFBD><E9B7B3> rowstatus<75><73><EFBFBD><EFBFBD>һ<EFBFBD><D2BB><EFBFBD>ڵ<EFBFBD><DAB5><EFBFBD><E3B6A8><EFBFBD>ˡ<EFBFBD>
-- <20><>λ<EFBFBD><CEBB><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ʣ<EFBFBD>ʮλ<CAAE><CEBB><EFBFBD><EFBFBD>˫<EFBFBD><CBAB>ģʽ<C4A3><CABD><EFBFBD><EFBFBD><EFBFBD>磺ǧ<E7A3BA>װ<EFBFBD>˫<EFBFBD><CBAB><EFBFBD><EFBFBD><EFBFBD><EFBFBD> 23
::= { inactiveUniqueEportEntry 4 }
-- 1.1.2.7.9. inactiveUniqueTcontTable ----------------------
inactiveUniqueTcontTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveUniqueTcontEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain unique tcont table, now only for tcont bind dba."
::= { inactiveUniqueConfig 9 }
inactiveUniqueTcontEntry OBJECT-TYPE
SYNTAX InactiveUniqueTcontEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive unique tcont table"
INDEX { inactiveUniqueIndexVIII, inactiveUniqueTcontIndex }
::= { inactiveUniqueTcontTable 1 }
InactiveUniqueTcontEntry ::=
SEQUENCE
{
inactiveUniqueIndexVIII INTEGER,
inactiveUniqueTcontIndex INTEGER,
inactiveUniqueTcontDbaIndex INTEGER,
inactiveUniqueTcontRowStatus RowStatus
}
inactiveUniqueIndexVIII OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 1st index of this table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveUniqueTcontEntry 1 }
inactiveUniqueTcontIndex OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of tcont, the 2nd index of this table.
Should in <1-8>."
::= { inactiveUniqueTcontEntry 2 }
inactiveUniqueTcontDbaIndex OBJECT-TYPE
SYNTAX INTEGER(0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The index of tcont bind dba, should be inputted with <0-127>."
::= { inactiveUniqueTcontEntry 3 }
inactiveUniqueTcontRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveUniqueTcontEntry 4 }
-- 1.1.2.7.10. inactiveUniqueAlarmRefTable --------------------
inactiveUniqueAlarmRefTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveUniqueAlarmRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive unique alarm Reference table."
::= { inactiveUniqueConfig 10 }
inactiveUniqueAlarmRefEntry OBJECT-TYPE
SYNTAX InactiveUniqueAlarmRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive unique alarm Reference table"
INDEX { inactiveUniqueAlarmRefUIndex }
::= { inactiveUniqueAlarmRefTable 1 }
InactiveUniqueAlarmRefEntry ::=
SEQUENCE
{
inactiveUniqueAlarmRefUIndex INTEGER,
inactiveUniqueAlarmRefAIndex INTEGER,
inactiveUniqueAlarmRefAName OCTET STRING,
inactiveUniqueAlarmRefRowStatus RowStatus
}
inactiveUniqueAlarmRefUIndex OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unique index of this table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveUniqueAlarmRefEntry 1 }
inactiveUniqueAlarmRefAIndex OBJECT-TYPE
SYNTAX INTEGER(0..127)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The index of alarm table to reference, Should in <0-127>."
::= { inactiveUniqueAlarmRefEntry 2 }
inactiveUniqueAlarmRefAName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..128))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entry name of alarm table to reference, Should in <1-128>."
::= { inactiveUniqueAlarmRefEntry 3 }
inactiveUniqueAlarmRefRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of inactive unique alarm Reference table."
::= { inactiveUniqueAlarmRefEntry 4 }
-- 1.1.2.7.11. inactiveUniqueManageTable
inactiveUniqueManageTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveUniqueManageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive unique management table."
::= { inactiveUniqueConfig 11 }
inactiveUniqueManageEntry OBJECT-TYPE
SYNTAX InactiveUniqueManageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive unique management table"
INDEX { inactiveUniqueManageIndex }
::= { inactiveUniqueManageTable 1 }
InactiveUniqueManageEntry ::=
SEQUENCE
{
inactiveUniqueManageIndex INTEGER,
inactiveUniqueManageProtocolPort80 INTEGER
}
inactiveUniqueManageIndex OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unique index of this table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveUniqueManageEntry 1 }
inactiveUniqueManageProtocolPort80 OBJECT-TYPE
SYNTAX INTEGER { disable_discard(0),
disable_forward(1),
enable_discard(2),
enable_forward(3),
init(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set protocol-port-80 disable mode discard or enable mode forward."
::= { inactiveUniqueManageEntry 2 }
-- 1.1.2.7.12. inactiveUniqueWanTable
inactiveUniqueWanTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveUniqueWanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive unique wan table."
::= { inactiveUniqueConfig 12 }
inactiveUniqueWanEntry OBJECT-TYPE
SYNTAX InactiveUniqueWanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive unique wan table"
INDEX { inactiveUniqueWanIndex, inactiveUniqueWanNo }
::= { inactiveUniqueWanTable 1 }
InactiveUniqueWanEntry ::=
SEQUENCE
{
inactiveUniqueWanIndex INTEGER,
inactiveUniqueWanNo INTEGER,
inactiveUniqueWanMode INTEGER,
inactiveUniqueWanVlan INTEGER,
inactiveUniqueWanPriority INTEGER,
inactiveUniqueWanPppoeUsername OCTET STRING,
inactiveUniqueWanPppoePassword OCTET STRING,
inactiveUniqueWanPppoeSerName OCTET STRING,
inactiveUniqueWanPppoeAuthMode INTEGER,
inactiveUniqueWanPppoeConnMode INTEGER,
inactiveUniqueWanPppoeNat INTEGER,
inactiveUniqueWanPppoeReleTime INTEGER,
inactiveUniqueWanStaticIp IpAddress,
inactiveUniqueWanStaticMask IpAddress,
inactiveUniqueWanStaticGateway IpAddress,
inactiveUniqueWanStaticMasterDns IpAddress,
inactiveUniqueWanStaticSlaveDns IpAddress,
inactiveUniqueWanRowStatus RowStatus
}
inactiveUniqueWanIndex OBJECT-TYPE
SYNTAX INTEGER(0..2047)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unique index of this table, should be inputted with <0-2047>.
The range is not always fit, please see range in commands."
::= { inactiveUniqueWanEntry 1 }
inactiveUniqueWanNo OBJECT-TYPE
SYNTAX INTEGER(1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unique index of this table, should be inputted with <1-4>."
::= { inactiveUniqueWanEntry 2 }
inactiveUniqueWanMode OBJECT-TYPE
SYNTAX INTEGER { pppoe(1),
dhcp(2),
static_ip(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The unique wan mode of this table, should be inputted with <1-3>."
::= { inactiveUniqueWanEntry 3 }
inactiveUniqueWanVlan OBJECT-TYPE
SYNTAX INTEGER (0..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The unique wan vlan of this table, should be inputted with <1-4094>.
0 - Initial value and cannot be set to this value.
1..4094 - Valid Settings."
::= { inactiveUniqueWanEntry 4 }
inactiveUniqueWanPriority OBJECT-TYPE
SYNTAX INTEGER(0..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The unique wan vlan priority of this table, should be inputted with <0-7>.
0..7 - Valid Settings.
8 - Initial value and cannot be set to this value."
::= { inactiveUniqueWanEntry 5 }
inactiveUniqueWanPppoeUsername OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The unique wan pppoe mode user name of this table.
0 - Initial len and cannot be set to this len.
1..128 - Valid Settings."
::= { inactiveUniqueWanEntry 6 }
inactiveUniqueWanPppoePassword OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..25))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The unique wan pppoe mode password of this table.
0 - Initial len and cannot be set to this len.
1..25 - Valid Settings."
::= { inactiveUniqueWanEntry 7 }
inactiveUniqueWanPppoeSerName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The unique wan pppoe mode service name of this table.
0 - Initial len and cannot be set to this len.
1..128 - Valid Settings."
::= { inactiveUniqueWanEntry 8 }
inactiveUniqueWanPppoeAuthMode OBJECT-TYPE
SYNTAX INTEGER { auto(0),
chap(1),
pap(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The unique wan pppoe mode authentication mode of this table.
0 - auto (the default)
1 - chap
2 - pap"
::= { inactiveUniqueWanEntry 9 }
inactiveUniqueWanPppoeConnMode OBJECT-TYPE
SYNTAX INTEGER { always(0),
demand(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The unique wan pppoe mode connection mode of this table.
0 - always (the default)
1 - demand"
::= { inactiveUniqueWanEntry 10 }
inactiveUniqueWanPppoeNat OBJECT-TYPE
SYNTAX INTEGER { disable(0),
enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The unique wan pppoe mode NAT of this table.
0 - disable
1 - enable(the default)"
::= { inactiveUniqueWanEntry 11 }
inactiveUniqueWanPppoeReleTime OBJECT-TYPE
SYNTAX INTEGER(0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The unique wan pppoe mode release time of this table, should be inputted with <1-65535>.
0 - Initial value and cannot be set to this value.
1..65535 - Valid Settings."
::= { inactiveUniqueWanEntry 12 }
inactiveUniqueWanStaticIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The unique wan static ip mode ip address of this table."
::= { inactiveUniqueWanEntry 13 }
inactiveUniqueWanStaticMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The unique wan static ip mode ip mask of this table."
::= { inactiveUniqueWanEntry 14 }
inactiveUniqueWanStaticGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The unique wan static ip mode ip gateway of this table."
::= { inactiveUniqueWanEntry 15 }
inactiveUniqueWanStaticMasterDns OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The unique wan static ip mode master DNS of this table."
::= { inactiveUniqueWanEntry 16 }
inactiveUniqueWanStaticSlaveDns OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The unique wan static ip mode slave DNS of this table."
::= { inactiveUniqueWanEntry 17 }
inactiveUniqueWanRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveUniqueWanEntry 18 }
-- 1.1.2.8. inactiveCtrlMcastConfig --------------------------
inactiveCtrlMcastConfig OBJECT IDENTIFIER ::= { deployInactive 8 }
-- 1.1.2.8.1. inactiveCtrlMcastTable
-- 1.1.2.8.2. inactiveCtrlMcastOntTable
-- 1.1.2.8.1. inactiveCtrlMcastTable --------------------------
inactiveCtrlMcastTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveCtrlMcastEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive control multicast table."
::= { inactiveCtrlMcastConfig 1 }
inactiveCtrlMcastEntry OBJECT-TYPE
SYNTAX InactiveCtrlMcastEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive control muticast table"
INDEX { inactiveCtrlMcastIndex }
::= { inactiveCtrlMcastTable 1 }
InactiveCtrlMcastEntry ::=
SEQUENCE
{
inactiveCtrlMcastIndex INTEGER,
inactiveCtrlMcastName OCTET STRING,
inactiveCtrlMcastRowStatus RowStatus
}
inactiveCtrlMcastIndex OBJECT-TYPE
SYNTAX INTEGER(0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of inactive control multicast table, should be inputted with <0-127>.
The range is not always fit, please see range in commands."
::= { inactiveCtrlMcastEntry 1 }
inactiveCtrlMcastName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"name of inactive control multicast entry."
::= { inactiveCtrlMcastEntry 2 }
inactiveCtrlMcastRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveCtrlMcastEntry 3 }
-- 1.1.2.8.2. inactiveCtrlMcastOntTable ------------------------
inactiveCtrlMcastOntTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveCtrlMcastOntEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive domain control multicast base ont table."
::= { inactiveCtrlMcastConfig 2 }
inactiveCtrlMcastOntEntry OBJECT-TYPE
SYNTAX InactiveCtrlMcastOntEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive control multicast base ont table"
INDEX { inactiveCtrlMcastIndexI, inactiveCtrlMcastEntryIndex }
::= { inactiveCtrlMcastOntTable 1 }
InactiveCtrlMcastOntEntry ::=
SEQUENCE
{
inactiveCtrlMcastIndexI INTEGER,
inactiveCtrlMcastEntryIndex INTEGER,
inactiveCtrlMcastAccessType INTEGER,
inactiveCtrlMcastVid INTEGER,
inactiveCtrlMcastSrcIp IpAddress,
inactiveCtrlMcastDstStartIp IpAddress,
inactiveCtrlMcastDstEndIp IpAddress,
inactiveCtrlMcastGroupBw INTEGER,
inactiveCtrlMcastDurationTimes INTEGER,
inactiveCtrlMcastNumOfTimes INTEGER,
inactiveCtrlMcastTimeInterval INTEGER,
inactiveCtrlMcastResetTime INTEGER,
inactiveCtrlMcastNport INTEGER,
inactiveCtrlMcastOntRowStatus RowStatus
}
inactiveCtrlMcastIndexI OBJECT-TYPE
SYNTAX INTEGER(0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of control multicast profile. Should in <0-127>."
::= { inactiveCtrlMcastOntEntry 1 }
inactiveCtrlMcastEntryIndex OBJECT-TYPE
SYNTAX INTEGER(0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of control multicast entry, the 2nd index of this table. Should in <0-31>."
::= { inactiveCtrlMcastOntEntry 2 }
inactiveCtrlMcastAccessType OBJECT-TYPE
SYNTAX INTEGER(0..3)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"inactiveCtrlMcastAccessType:
0 del one entry
1 clear all entry
2 add permit entry
3 add preview entry"
::= { inactiveCtrlMcastOntEntry 3 }
inactiveCtrlMcastVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"control multicast vlan id, should be <1-4094>."
::= { inactiveCtrlMcastOntEntry 4 }
inactiveCtrlMcastSrcIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"control multicast source ip address."
::= { inactiveCtrlMcastOntEntry 5 }
inactiveCtrlMcastDstStartIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"control multicast destination start ip address."
::= { inactiveCtrlMcastOntEntry 6 }
inactiveCtrlMcastDstEndIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"control multicast destination end ip address."
::= { inactiveCtrlMcastOntEntry 7 }
inactiveCtrlMcastGroupBw OBJECT-TYPE
SYNTAX INTEGER(1..1024000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"control multicast group bandwidth, should be <1-1024000>."
::= { inactiveCtrlMcastOntEntry 8 }
inactiveCtrlMcastDurationTimes OBJECT-TYPE
SYNTAX INTEGER(10..6000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"control multicast duration times, should be <10-6000>."
::= { inactiveCtrlMcastOntEntry 9 }
inactiveCtrlMcastNumOfTimes OBJECT-TYPE
SYNTAX INTEGER(1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"control multicast number of times, should be <1-255>."
::= { inactiveCtrlMcastOntEntry 10 }
inactiveCtrlMcastTimeInterval OBJECT-TYPE
SYNTAX INTEGER(1..7200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"control multicast time interval, should be <1-7200>."
::= { inactiveCtrlMcastOntEntry 11 }
inactiveCtrlMcastResetTime OBJECT-TYPE
SYNTAX INTEGER(1..24)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"control multicast reset time o'clock, should be <1-24>."
::= { inactiveCtrlMcastOntEntry 12 }
inactiveCtrlMcastNport OBJECT-TYPE
SYNTAX INTEGER(1..25)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ethernet port number 1-24 of the entry assigned, default 25 means ctrl mcast base ont."
::= { inactiveCtrlMcastOntEntry 13 }
inactiveCtrlMcastOntRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { inactiveCtrlMcastOntEntry 14 }
-- 1.1.2.9. inactiveCtrlAlarmConfig --------------------------
inactiveCtrlAlarmConfig OBJECT IDENTIFIER ::= { deployInactive 9 }
-- 1.1.2.9.1. inactiveCtrlAlarmTable
-- 1.1.2.9.2. inactiveCtrlAlarmThrldTable
-- 1.1.2.9.1. inactiveCtrlAlarmTable --------------------------
inactiveCtrlAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveCtrlAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive control alarm table."
::= { inactiveCtrlAlarmConfig 1 }
inactiveCtrlAlarmEntry OBJECT-TYPE
SYNTAX InactiveCtrlAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive control alarm table"
INDEX { inactiveCtrlAlarmAimIndex }
::= { inactiveCtrlAlarmTable 1 }
InactiveCtrlAlarmEntry ::=
SEQUENCE
{
inactiveCtrlAlarmAimIndex INTEGER,
inactiveCtrlAlarmAimName OCTET STRING,
inactiveCtrlAlarmReferLine OCTET STRING,
inactiveCtrlAlarmReferUnique OCTET STRING,
inactiveCtrlAlarmRowStatus RowStatus
}
inactiveCtrlAlarmAimIndex OBJECT-TYPE
SYNTAX INTEGER(0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of inactive control alarm table, should be <0-127>.
The range is not always fit, please see range in commands."
::= { inactiveCtrlAlarmEntry 1 }
inactiveCtrlAlarmAimName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..128))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"the name of aim."
::= { inactiveCtrlAlarmEntry 2 }
inactiveCtrlAlarmReferLine OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line bitmap, each line references this aim."
::= { inactiveCtrlAlarmEntry 3 }
inactiveCtrlAlarmReferUnique OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique bitmap, each unique references this aim."
::= { inactiveCtrlAlarmEntry 4 }
inactiveCtrlAlarmRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The inactive control alarm table rowStatus."
::= { inactiveCtrlAlarmEntry 5 }
-- 1.1.2.9.2. inactiveCtrlAlarmThrldTable --------------------------
inactiveCtrlAlarmThrldTable OBJECT-TYPE
SYNTAX SEQUENCE OF InactiveCtrlAlarmThrldEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"inactive control alarm threshold table."
::= { inactiveCtrlAlarmConfig 2 }
inactiveCtrlAlarmThrldEntry OBJECT-TYPE
SYNTAX InactiveCtrlAlarmThrldEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of inactive control alarm threshold table"
INDEX { inactiveCtrlAlarmThrldAimIndex, inactiveCtrlAlarmThrldRxOrTx}
::= { inactiveCtrlAlarmThrldTable 1 }
InactiveCtrlAlarmThrldEntry ::=
SEQUENCE
{
inactiveCtrlAlarmThrldAimIndex INTEGER,
inactiveCtrlAlarmThrldRxOrTx INTEGER,
inactiveCtrlAlarmThrldHigh INTEGER,
inactiveCtrlAlarmThrldLow INTEGER
}
inactiveCtrlAlarmThrldAimIndex OBJECT-TYPE
SYNTAX INTEGER(0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of inactive control alarm threshold table, should be <0-127>.
The range is not always fit, please see range in commands."
::= { inactiveCtrlAlarmThrldEntry 1 }
inactiveCtrlAlarmThrldRxOrTx OBJECT-TYPE
SYNTAX INTEGER { none(0), rx(1), tx(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The secend index of inactive control alarm threshold entry."
::= { inactiveCtrlAlarmThrldEntry 2 }
inactiveCtrlAlarmThrldHigh OBJECT-TYPE
SYNTAX INTEGER(0..254)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The high threshold of rx or tx alarm, The actual value is half the input value,
if the threshold is rx, the actual value is the opposite."
::= { inactiveCtrlAlarmThrldEntry 3 }
inactiveCtrlAlarmThrldLow OBJECT-TYPE
SYNTAX INTEGER(0..254)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The low threshold of rx or tx alarm, The actual value is half the input value,
if the threshold is rx, the actual value is the opposite."
::= { inactiveCtrlAlarmThrldEntry 4 }
-- 1.1.3. deployActive ----------------------------------
deployActive OBJECT IDENTIFIER ::= { configDevice 3 }
-- 1.1.3.1. activeAuthTable
-- 1.1.3.2. activeDbaTable
-- 1.1.3.3. activeLineCommonConfig
-- 1.1.3.4. activeLineSFUConfig
-- 1.1.3.5. activeLineHGUConfig
-- 1.1.3.6. activeRuleTable
-- 1.1.3.7. activeUniqueConfig
-- 1.1.3.1. activeAuthTable ------------------------------
activeAuthTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActiveAuthEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"active domain auth table"
::= { deployActive 1 }
activeAuthEntry OBJECT-TYPE
SYNTAX ActiveAuthEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of active auth table"
INDEX { activeAuthIndex }
::= { activeAuthTable 1 }
ActiveAuthEntry ::=
SEQUENCE
{
activeAuthIndex INTEGER,
activeAuthDescription OCTET STRING,
activeAuthMode INTEGER,
activeAuthSn OCTET STRING,
activeAuthPw OCTET STRING,
activeAuthLoid OCTET STRING,
activeAuthLopw OCTET STRING,
activeAuthAssignedSlot OCTET STRING,
activeAuthAssignedPport OCTET STRING,
activeAuthAssignedOnt OCTET STRING
}
activeAuthIndex OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of active auth table, should be inputted with <0-4095>.
The range is not always fit, please see range in commands."
::= { activeAuthEntry 1 }
activeAuthDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"auth description, max length: 128."
::= { activeAuthEntry 2 }
activeAuthMode OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeAuthMode:
0 auth mode sn
1 auth mode pw
2 auth mode sn_pw
3 auth mode loid
4 auth mode lopw
5 auth mode loid_lopw"
::= { activeAuthEntry 3 }
activeAuthSn OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"auth sn, string-hex, max length: 16."
::= { activeAuthEntry 4 }
activeAuthPw OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"auth password, string, max length: 20."
::= { activeAuthEntry 5 }
activeAuthLoid OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"auth loid, max length: 24."
::= { activeAuthEntry 6 }
activeAuthLopw OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"auth logic password, max length: 12."
::= { activeAuthEntry 7 }
activeAuthAssignedSlot OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"slot id pre assigned. if not configed, its '-'."
::= { activeAuthEntry 8 }
activeAuthAssignedPport OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"pon port id pre assigned. if not configed, its '-'."
::= { activeAuthEntry 9 }
activeAuthAssignedOnt OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont id pre assigned. if not configed, its '-'."
::= { activeAuthEntry 10 }
-- 1.1.3.2. activeDbaTable ------------------------------
activeDbaTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActiveDbaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"active domain dba table"
::= { deployActive 2 }
activeDbaEntry OBJECT-TYPE
SYNTAX ActiveDbaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of active dba table"
INDEX { activeDbaIndex }
::= { activeDbaTable 1 }
ActiveDbaEntry ::=
SEQUENCE
{
activeDbaIndex INTEGER,
activeDbaDescription OCTET STRING,
activeDbaType INTEGER,
activeDbaFixBandwidth INTEGER,
activeDbaAssuredBandwidth INTEGER,
activeDbaMaxBandwidth INTEGER
}
activeDbaIndex OBJECT-TYPE
SYNTAX INTEGER(0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of active dba table, should be inputted with <0-127>."
::= { activeDbaEntry 1 }
activeDbaDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"active dba description, max length: 128."
::= { activeDbaEntry 2 }
activeDbaType OBJECT-TYPE
SYNTAX INTEGER(1..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeDbaType,
1 fixed bandwidth
2 assured bandwidth
3 assured and max bandwidth
4 max bandwidth
5 fixed and assured and max bandwidth"
::= { activeDbaEntry 3 }
activeDbaFixBandwidth OBJECT-TYPE
SYNTAX INTEGER(128..1310720)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Must to be divisible by 64kbps, must not less than 128 kbps."
::= { activeDbaEntry 4 }
activeDbaAssuredBandwidth OBJECT-TYPE
SYNTAX INTEGER(0..1310592)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Must to be divisible by 64kbps, Can be 0.
If not 0, it must be at least 256 kbps."
::= { activeDbaEntry 5 }
activeDbaMaxBandwidth OBJECT-TYPE
SYNTAX INTEGER(0..1310720)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Must to be divisible by 64kbps, and must not be less than
the sum of assured BW plus fixedBW.
Must less than 1310720 kbps"
::= { activeDbaEntry 6 }
-- 1.1.3.3. activeLineCommonConfig ----------------------
activeLineCommonConfig OBJECT IDENTIFIER ::= { deployActive 3 }
-- 1.1.3.3.1. activeLinePrimaryTable
-- 1.1.3.3.2. activeLineTcontTable
-- 1.1.3.3.3. activeLineGemportTable
-- 1.1.3.3.4. activeLineFlowmappingTable
-- 1.1.3.3.5. activeLineAttrMgmtTable
-- 1.1.3.3.1. activeLinePrimaryTable --------------------
activeLinePrimaryTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActiveLinePrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"active domain line primary table"
::= { activeLineCommonConfig 1 }
activeLinePrimaryEntry OBJECT-TYPE
SYNTAX ActiveLinePrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of active line primary table"
INDEX { activeLineIndex }
::= { activeLinePrimaryTable 1 }
ActiveLinePrimaryEntry ::=
SEQUENCE
{
activeLineIndex INTEGER,
activeLineDeviceType OCTET STRING,
activeLineDescription OCTET STRING,
activeLineTrafficMode INTEGER,
activeLineMappingMode INTEGER
}
activeLineIndex OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of line primary table, should be inputted with <0-4095>.
The range is not always fit, please see range in commands."
::= { activeLinePrimaryEntry 1 }
activeLineDeviceType OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(7..7))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineDeviceType:
c30-214 2ETH(1ETH+1iTV)+1POTS SFU
c30-400 4ETH SFU
c30-401 4ETH+WIFI HGU
c30-420 4ETH+2POTS SFU
c30-423 4ETH+2POTS+WIFI+USB HGU
c31-423 4ETH+2POTS+WIFI+USB HGU+SFU
c40-100 1ETH SFU
c40-201 2ETH+WIFI HGU
c40-210 1GE+1FE+1POTS HGU
c40-427 4ETH(3ETH+1iTV)+2POTS+WIFI+USB HGU
d10-423 4ETH+2POTS+WIFI+USB HGU
f10-427 4ETH(3ETH+1iTV)+2POTS+WIFI+USB HGU
h60-100 1ETH SFU
l30-100 1ETH SFU
l30-210 2ETH+1POTS SFU
m50-420 4ETH+2POTS SFU
n20-100 1ETH SFU
n20-400 4ETH SFU
n40-100 1ETH SFU
s10-214 2ETH(1ETH+1iTV)+1POTS HGU
s30-100 1ETH SFU
t10-100 1ETH SFU
t10-214 2ETH(1ETH+1iTV)+1POTS SFU
t10-403 4ETH+WIFI+USB HGU
t10-420 4ETH+2POTS SFU
t10-423 4ETH+2POTS+WIFI+USB HGU
t10-427 4ETH(3ETH+1iTV)+2POTS+WIFI+USB HGU
t60-100 1ETH SFU"
::= { activeLinePrimaryEntry 2 }
activeLineDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"line description, max length: 128."
::= { activeLinePrimaryEntry 3 }
activeLineTrafficMode OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineTrafficMode:
0 pri-queue: priority queue scheduling
1 gem-car: GEM traffic control"
::= { activeLinePrimaryEntry 4 }
activeLineMappingMode OBJECT-TYPE
SYNTAX INTEGER(0..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineMappingMode:
0 vlan
1 priority
2 vlan-priority
3 port
4 port-vlan
5 port-priority
6 port-vlan-priority"
::= { activeLinePrimaryEntry 5 }
-- 1.1.3.3.2. activeLineTcontTable ----------------------
activeLineTcontTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActiveLineTcontEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"active domain line tcont table, now only for tcont bind dba."
::= { activeLineCommonConfig 2 }
activeLineTcontEntry OBJECT-TYPE
SYNTAX ActiveLineTcontEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of active line tcont table"
INDEX { activeLineIndexI, activeLineTcontIndex }
::= { activeLineTcontTable 1 }
ActiveLineTcontEntry ::=
SEQUENCE
{
activeLineIndexI INTEGER,
activeLineTcontIndex INTEGER,
activeLineTcontDbaIndex INTEGER
}
activeLineIndexI OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of line primary table, should be inputted with <0-4095>.
The range is not always fit, please see range in commands."
::= { activeLineTcontEntry 1 }
activeLineTcontIndex OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of tcont, the 2nd index of this table.
Should in <1-8>."
::= { activeLineTcontEntry 2 }
activeLineTcontDbaIndex OBJECT-TYPE
SYNTAX INTEGER(0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of tcont bind dba, should be inputted with <0-127>."
::= { activeLineTcontEntry 3 }
-- 1.1.3.3.3. activeLineGemportTable --------------------
activeLineGemportTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActiveLineGemportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"active domain line gemport table."
::= { activeLineCommonConfig 3 }
activeLineGemportEntry OBJECT-TYPE
SYNTAX ActiveLineGemportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of active line gemport table"
INDEX { activeLineIndexII, activeLineGemportIndex }
::= { activeLineGemportTable 1 }
ActiveLineGemportEntry ::=
SEQUENCE
{
activeLineIndexII INTEGER,
activeLineGemportIndex INTEGER,
activeLineGemportVpStagged INTEGER,
activeLineGemportSvid INTEGER,
activeLineGemportPriority INTEGER,
activeLineGemportTcontId INTEGER,
activeLineGemportPq INTEGER,
activeLineGemportCir INTEGER,
activeLineGemportPir INTEGER,
activeLineGemportCbs INTEGER,
activeLineGemportPbs INTEGER
}
activeLineIndexII OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of line primary table, should be inputted with <0-4095>.
The range is not always fit, please see range in commands."
::= { activeLineGemportEntry 1 }
activeLineGemportIndex OBJECT-TYPE
SYNTAX INTEGER(1..24)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of gemport, the 2nd index of this table.
Should in <1-24>."
::= { activeLineGemportEntry 2 }
activeLineGemportVpStagged OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineGemportVpStagged:
0 false
1 true"
::= { activeLineGemportEntry 3 }
activeLineGemportSvid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The gemport service vlan index, should be inputted with <1-4094>."
::= { activeLineGemportEntry 4 }
activeLineGemportPriority OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The gemport priority, should be inputted with <0-7>. Now not use."
::= { activeLineGemportEntry 5 }
activeLineGemportTcontId OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The gemport bind tcont index, should be inputted with <1-8>."
::= { activeLineGemportEntry 6 }
activeLineGemportPq OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The gemport priority queue, should be inputted with <0-7>."
::= { activeLineGemportEntry 7 }
activeLineGemportCir OBJECT-TYPE
SYNTAX INTEGER(64..1310720)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The gemport committed infomation rate, should be inputted with <64-10240000>.
must to be divisible by 64kbps,must not less than 64 kbps."
::= { activeLineGemportEntry 8 }
activeLineGemportPir OBJECT-TYPE
SYNTAX INTEGER(64..1310720)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The gemport peek infomation rate, should be inputted with <64-10240000>.
must to be divisible by 64kbps,must not less than 64 kbps."
::= { activeLineGemportEntry 9 }
activeLineGemportCbs OBJECT-TYPE
SYNTAX INTEGER(2000..1310720)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The gemport committed burst size, should be inputted with <2000-10240000>."
::= { activeLineGemportEntry 10 }
activeLineGemportPbs OBJECT-TYPE
SYNTAX INTEGER(2000..1310720)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The gemport peek burst size, should be inputted with <2000-10240000>."
::= { activeLineGemportEntry 11 }
-- 1.1.3.3.4. activeLineFlowmappingTable ----------------
activeLineFlowmappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActiveLineFlowmappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"active domain line flow mapping table."
::= { activeLineCommonConfig 4 }
activeLineFlowmappingEntry OBJECT-TYPE
SYNTAX ActiveLineFlowmappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of active line flow mapping table"
INDEX { activeLineIndexIII, activeLineFlowmappingIndex }
::= { activeLineFlowmappingTable 1 }
ActiveLineFlowmappingEntry ::=
SEQUENCE
{
activeLineIndexIII INTEGER,
activeLineFlowmappingIndex INTEGER,
activeLineFlowmappingVid INTEGER,
activeLineFlowmappingPriority INTEGER,
activeLineFlowmappingEthport INTEGER,
activeLineFlowmappingGemport INTEGER,
activeLineFlowmappingType INTEGER
}
activeLineIndexIII OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of line primary table, should be inputted with <0-4095>.
The range is not always fit, please see range in commands."
::= { activeLineFlowmappingEntry 1 }
activeLineFlowmappingIndex OBJECT-TYPE
SYNTAX INTEGER(1..48)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of flowmapping, the 2nd index of this table. Should in <1-48>.
The range is not always fit, please see range in commands."
::= { activeLineFlowmappingEntry 2 }
activeLineFlowmappingVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The flow mapping vid, should be inputted with <1-4094>."
::= { activeLineFlowmappingEntry 3 }
activeLineFlowmappingPriority OBJECT-TYPE
SYNTAX INTEGER(0..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The flow mapping priority, should be inputted with <0-8>.
Value 8 means don't care 802.1p priority."
::= { activeLineFlowmappingEntry 4 }
activeLineFlowmappingEthport OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The flow mapping ethernet port id, should be inputted with <1-8>."
::= { activeLineFlowmappingEntry 5 }
activeLineFlowmappingGemport OBJECT-TYPE
SYNTAX INTEGER(1..24)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The flow mapping gem port id, should be inputted with <1-24>."
::= { activeLineFlowmappingEntry 6 }
activeLineFlowmappingType OBJECT-TYPE
SYNTAX INTEGER(0..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineFlowmappingType:
0 flowmapping not base port.
1 flowmapping base eth port.
2 flowmapping base veip port.
3. flowmapping base iphost port."
::= { activeLineFlowmappingEntry 7 }
-- 1.1.3.3.5. activeLineAttrMgmtTable --------------------
activeLineAttrMgmtTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActiveLineAttrMgmtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"active domain line attribute management table."
::= { activeLineCommonConfig 5 }
activeLineAttrMgmtEntry OBJECT-TYPE
SYNTAX ActiveLineAttrMgmtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of active line attribute management table"
INDEX { activeLineIndexIV, activeLineAttrMgmtIndex }
::= { activeLineAttrMgmtTable 1 }
ActiveLineAttrMgmtEntry ::=
SEQUENCE
{
activeLineIndexIV INTEGER,
activeLineAttrMgmtIndex INTEGER,
activeLineAttrMgmtNportType INTEGER,
activeLineAttrMgmtNport INTEGER,
activeLineAttrMgmtEtypeFilter INTEGER,
activeLineAttrMgmtVlanMode INTEGER,
activeLineAttrMgmtCvlanVid INTEGER,
activeLineAttrMgmtCvlanPri INTEGER,
activeLineAttrMgmtSvlanVid INTEGER,
activeLineAttrMgmtSvlanPri INTEGER
}
activeLineIndexIV OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of line primary table, should be inputted with <0-4095>.
The range is not always fit, please see range in commands."
::= { activeLineAttrMgmtEntry 1 }
activeLineAttrMgmtIndex OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of attribute management, the 2nd index of this table. Should in <1-64>."
::= { activeLineAttrMgmtEntry 2 }
activeLineAttrMgmtNportType OBJECT-TYPE
SYNTAX INTEGER(1..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineAttrMgmtNportType:
1 eth port in sfu
2 veip port in hgu
3 iphost virtual port, for voip, tdm, etc."
::= { activeLineAttrMgmtEntry 3 }
activeLineAttrMgmtNport OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port of attribute management, if eport, should in <1-8>."
::= { activeLineAttrMgmtEntry 4 }
activeLineAttrMgmtEtypeFilter OBJECT-TYPE
SYNTAX INTEGER(0..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineAttrMgmtEtypeFilter:
0 no filter
1 filter ipoe frame
2 filter pppoe frame
3 filter arp frame"
::= { activeLineAttrMgmtEntry 5 }
activeLineAttrMgmtVlanMode OBJECT-TYPE
SYNTAX INTEGER(0..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineAttrMgmtVlanMode:
0 transparent
1 tag
2 translation
3 trunk
4 QinQ"
::= { activeLineAttrMgmtEntry 6 }
activeLineAttrMgmtCvlanVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"cvlan vid, should be inputted with <1-4094>."
::= { activeLineAttrMgmtEntry 7 }
activeLineAttrMgmtCvlanPri OBJECT-TYPE
SYNTAX INTEGER(0..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The cvlan priority, should be inputted with <0-8>.
Value 8 means don't care vlan priority."
::= { activeLineAttrMgmtEntry 8 }
activeLineAttrMgmtSvlanVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"svlan vid, should be inputted with <1-4094>."
::= { activeLineAttrMgmtEntry 9 }
activeLineAttrMgmtSvlanPri OBJECT-TYPE
SYNTAX INTEGER(0..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"svlan priority, should be inputted with <0-8>.
Value 8 means don't care vlan priority."
::= { activeLineAttrMgmtEntry 10 }
-- 1.1.3.4. activeLineSFUConfig --------------------------
activeLineSFUConfig OBJECT IDENTIFIER ::= { deployActive 4 }
-- 1.1.3.4.1. activeLineSFUTable
-- 1.1.3.4.2. activeLineSFUEthportTable
-- 1.1.3.4.3. activeLineSFUCtrlMcastTable
-- 1.1.3.4.1. activeLineSFUTable ------------------------
activeLineSFUTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActiveLineSFUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"active domain line SFU primary table."
::= { activeLineSFUConfig 1 }
activeLineSFUEntry OBJECT-TYPE
SYNTAX ActiveLineSFUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of active line sfu primary table"
INDEX { activeLineIndexV }
::= { activeLineSFUTable 1 }
ActiveLineSFUEntry ::=
SEQUENCE
{
activeLineIndexV INTEGER,
activeLineSfuLocalSwitch INTEGER,
activeLineSfuLoopDetectSwitch INTEGER
}
activeLineIndexV OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of line primary table, should be inputted with <0-4095>.
The range is not always fit, please see range in commands."
::= { activeLineSFUEntry 1 }
activeLineSfuLocalSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineSfuLocalSwitch:
0 disable(default)
1 enable."
::= { activeLineSFUEntry 2 }
activeLineSfuLoopDetectSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineSfuLoopDetectSwitch:
0 disable(default)
1 enable."
::= { activeLineSFUEntry 3 }
-- 1.1.3.4.2. activeLineSFUEthportTable ------------------
activeLineSFUEthportTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActiveLineSFUEthportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"active domain line SFU ethernet port table."
::= { activeLineSFUConfig 2 }
activeLineSFUEthportEntry OBJECT-TYPE
SYNTAX ActiveLineSFUEthportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of active line SFU ethernet port table"
INDEX { activeLineIndexVI, activeLineSfuEthportIndex }
::= { activeLineSFUEthportTable 1 }
ActiveLineSFUEthportEntry ::=
SEQUENCE
{
activeLineIndexVI INTEGER,
activeLineSfuEthportIndex INTEGER,
activeLineSfuEthportSwitch INTEGER,
activeLineSfuEthportFlowCtrlSwitch INTEGER,
activeLineSfuEthportLoopbackSwitch INTEGER,
activeLineSfuEthportFastLeaveSwitch INTEGER,
activeLineSfuEthportMaxGroups INTEGER,
activeLineSfuEthportMaxMacCount INTEGER,
activeLineSfuEthportMcastMode INTEGER,
activeLineSfuEthportDsIgmpControlType INTEGER,
activeLineSfuEthportDsIgmpVid INTEGER,
activeLineSfuEthportDsIgmpPri INTEGER,
activeLineSfuEthportUsIgmpControlType INTEGER,
activeLineSfuEthportUsIgmpVid INTEGER,
activeLineSfuEthportUsIgmpPri INTEGER,
activeLineSfuEthportBwCir INTEGER,
activeLineSfuEthportBwCbs INTEGER,
activeLineSfuEthportBwPir INTEGER,
activeLineSfuEthportBwPbs INTEGER
}
activeLineIndexVI OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of line primary table, should be inputted with <0-4095>.
The range is not always fit, please see range in commands."
::= { activeLineSFUEthportEntry 1 }
activeLineSfuEthportIndex OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of SFU ethernet port, the 2nd index of this table. Should in <1-8>."
::= { activeLineSFUEthportEntry 2 }
activeLineSfuEthportSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineSfuEthportSwitch:
0 no shutdown(default)
1 shutdown"
::= { activeLineSFUEthportEntry 3 }
activeLineSfuEthportFlowCtrlSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineSfuEthportFlowCtrlSwitch:
0 disable(default)
1 enable"
::= { activeLineSFUEthportEntry 4 }
activeLineSfuEthportLoopbackSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineSfuEthportLoopbackSwitch:
0 disable(default)
1 enable"
::= { activeLineSFUEthportEntry 5 }
activeLineSfuEthportFastLeaveSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineSfuEthportFastLeaveSwitch:
0 disable(default)
1 enable"
::= { activeLineSFUEthportEntry 6 }
activeLineSfuEthportMaxGroups OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SFU ethernet port max igmp groups, should be inputted with <1-128>."
::= { activeLineSFUEthportEntry 7 }
activeLineSfuEthportMaxMacCount OBJECT-TYPE
SYNTAX INTEGER(1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SFU ethernet port max mac address count, should be inputted with <1-255>."
::= { activeLineSFUEthportEntry 8 }
activeLineSfuEthportMcastMode OBJECT-TYPE
SYNTAX INTEGER(0..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineSfuEthportMcastMode(some ont not support):
0 unconcern(default)
1 control
2 igmp snooping"
::= { activeLineSFUEthportEntry 9 }
activeLineSfuEthportDsIgmpControlType OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineSfuEthportDsIgmpControlType:
0 transparent(default)
1 strip outer tag
2 add tag
3 replace tag
4 replace only vid
5 add only vid"
::= { activeLineSFUEthportEntry 10 }
activeLineSfuEthportDsIgmpVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SFU ethernet port downstream igmp and multicast control vid,
should be inputted with <1-4094>."
::= { activeLineSFUEthportEntry 11 }
activeLineSfuEthportDsIgmpPri OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vlan priority, should be inputted with <0-7>."
::= { activeLineSFUEthportEntry 12 }
activeLineSfuEthportUsIgmpControlType OBJECT-TYPE
SYNTAX INTEGER(0..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineSfuEthportUsIgmpControlType:
0 transparent(default, only for read)
1 add tag
2 replace tag
3 replace only vid
4 add only vid"
::= { activeLineSFUEthportEntry 13 }
activeLineSfuEthportUsIgmpVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SFU ethernet port upstream igmp and multicast control vid,
should be inputted with <1-4094>."
::= { activeLineSFUEthportEntry 14 }
activeLineSfuEthportUsIgmpPri OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vlan priority, should be inputted with <0-7>."
::= { activeLineSFUEthportEntry 15 }
activeLineSfuEthportBwCir OBJECT-TYPE
SYNTAX INTEGER(64..1024000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SFU ethernet port bandwidth egress cir, should be inputted with <64-1024000>."
::= { activeLineSFUEthportEntry 16 }
activeLineSfuEthportBwCbs OBJECT-TYPE
SYNTAX INTEGER(2..32000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SFU ethernet port bandwidth egress cbs, should be inputted with <2-32000>."
::= { activeLineSFUEthportEntry 17 }
activeLineSfuEthportBwPir OBJECT-TYPE
SYNTAX INTEGER(64..1024000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SFU ethernet port bandwidth egress pir, should be inputted with <64-1024000>."
::= { activeLineSFUEthportEntry 18 }
activeLineSfuEthportBwPbs OBJECT-TYPE
SYNTAX INTEGER(2..32000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SFU ethernet port bandwidth egress pbs, should be inputted with <2-32000>."
::= { activeLineSFUEthportEntry 19 }
-- 1.1.3.4.3. activeLineSFUCtrlMcastTable ----------------
activeLineSFUCtrlMcastTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActiveLineSFUCtrlMcastEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"active domain line SFU ethernet port control multicast table."
::= { activeLineSFUConfig 3 }
activeLineSFUCtrlMcastEntry OBJECT-TYPE
SYNTAX ActiveLineSFUCtrlMcastEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of active line SFU ethernet port control multicast table"
INDEX { activeLineIndexVII, activeLineSfuEthportIndexI, activeLineSfuCtrlMcastIndex }
::= { activeLineSFUCtrlMcastTable 1 }
ActiveLineSFUCtrlMcastEntry ::=
SEQUENCE
{
activeLineIndexVII INTEGER,
activeLineSfuEthportIndexI INTEGER,
activeLineSfuCtrlMcastIndex INTEGER,
activeLineSfuCtrlMcastAccessType INTEGER,
activeLineSfuCtrlMcastVid INTEGER,
activeLineSfuCtrlMcastSrcIp IpAddress,
activeLineSfuCtrlMcastDstStartIp IpAddress,
activeLineSfuCtrlMcastDstEndIp IpAddress,
activeLineSfuCtrlMcastGroupBw INTEGER,
activeLineSfuCtrlMcastDurationTimes INTEGER,
activeLineSfuCtrlMcastNumOfTimes INTEGER,
activeLineSfuCtrlMcastTimeInterval INTEGER,
activeLineSfuCtrlMcastResetTime INTEGER
}
activeLineIndexVII OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of line primary table, should be inputted with <0-4095>.
The range is not always fit, please see range in commands."
::= { activeLineSFUCtrlMcastEntry 1 }
activeLineSfuEthportIndexI OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of SFU ethernet port, the 2nd index of this table. Should in <1-8>."
::= { activeLineSFUCtrlMcastEntry 2 }
activeLineSfuCtrlMcastIndex OBJECT-TYPE
SYNTAX INTEGER(0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of SFU ethernet port control multicast, the 3rd index of this table. Should in <0-31>."
::= { activeLineSFUCtrlMcastEntry 3 }
activeLineSfuCtrlMcastAccessType OBJECT-TYPE
SYNTAX INTEGER(2..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineSfuCtrlMcastAccessType:
0 del one entry -- no use
1 clear all entry -- no use
2 add permit entry
3 add preview entry"
::= { activeLineSFUCtrlMcastEntry 4 }
activeLineSfuCtrlMcastVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfu control multicast vlan id, should be <1-4094>."
::= { activeLineSFUCtrlMcastEntry 5 }
activeLineSfuCtrlMcastSrcIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfu control multicast source ip address."
::= { activeLineSFUCtrlMcastEntry 6 }
activeLineSfuCtrlMcastDstStartIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfu control multicast destination start ip address. 224.0.1.0-239.255.255.255"
::= { activeLineSFUCtrlMcastEntry 7 }
activeLineSfuCtrlMcastDstEndIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfu control multicast destination end ip address. 224.0.1.0-239.255.255.255,
must not smaller than the start ip address. "
::= { activeLineSFUCtrlMcastEntry 8 }
activeLineSfuCtrlMcastGroupBw OBJECT-TYPE
SYNTAX INTEGER(1..1024000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfu control multicast group bandwidth, should be <1-1024000>. default 5000."
::= { activeLineSFUCtrlMcastEntry 9 }
activeLineSfuCtrlMcastDurationTimes OBJECT-TYPE
SYNTAX INTEGER(10..6000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfu control multicast duration times, should be <10-6000>. default 120(s)."
::= { activeLineSFUCtrlMcastEntry 10 }
activeLineSfuCtrlMcastNumOfTimes OBJECT-TYPE
SYNTAX INTEGER(1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfu control multicast number of times, should be <1-255>. default 5."
::= { activeLineSFUCtrlMcastEntry 11 }
activeLineSfuCtrlMcastTimeInterval OBJECT-TYPE
SYNTAX INTEGER(1..7200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfu control multicast time interval, should be <1-7200>. default 120(s)."
::= { activeLineSFUCtrlMcastEntry 12 }
activeLineSfuCtrlMcastResetTime OBJECT-TYPE
SYNTAX INTEGER(1..24)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfu control multicast reset time, should be <1-24>. default 5(o'clock)"
::= { activeLineSFUCtrlMcastEntry 13 }
-- 1.1.3.5. activeLineHGUConfig --------------------------
activeLineHGUConfig OBJECT IDENTIFIER ::= { deployActive 5 }
-- 1.1.3.5.1. activeLineHGUTable
-- 1.1.3.5.2. activeLineHGUCtrlMcastTable
-- 1.1.3.5.1. activeLineHGUTable ------------------------
activeLineHGUTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActiveLineHGUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"active domain line HGU table."
::= { activeLineHGUConfig 1 }
activeLineHGUEntry OBJECT-TYPE
SYNTAX ActiveLineHGUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of active line HGU table"
INDEX { activeLineIndexVIII }
::= { activeLineHGUTable 1 }
ActiveLineHGUEntry ::=
SEQUENCE
{
activeLineIndexVIII INTEGER,
activeLineHguSwitch INTEGER,
activeLineHguFastLeaveSwitch INTEGER,
activeLineHguMaxGroups INTEGER,
activeLineHguMaxMacCount INTEGER,
activeLineHguMcastMode INTEGER,
activeLineHguDsIgmpControlType INTEGER,
activeLineHguDsIgmpVid INTEGER,
activeLineHguDsIgmpPri INTEGER,
activeLineHguUsIgmpControlType INTEGER,
activeLineHguUsIgmpVid INTEGER,
activeLineHguUsIgmpPri INTEGER
}
activeLineIndexVIII OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of line primary table, should be inputted with <0-4095>.
The range is not always fit, please see range in commands."
::= { activeLineHGUEntry 1 }
activeLineHguSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineHguSwitch:
0 no shutdown(default)
1 shutdown"
::= { activeLineHGUEntry 2 }
activeLineHguFastLeaveSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineHguFlowCtrlSwitch:
0 disable(default)
1 enable"
::= { activeLineHGUEntry 3 }
activeLineHguMaxGroups OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The HGU max igmp groups, should be inputted with <1-128>."
::= { activeLineHGUEntry 4 }
activeLineHguMaxMacCount OBJECT-TYPE
SYNTAX INTEGER(1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The HGU max mac address count, should be inputted with <1-255>."
::= { activeLineHGUEntry 5 }
activeLineHguMcastMode OBJECT-TYPE
SYNTAX INTEGER(0..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineHguMcastMode(some ont not support):
0 unconcern(default)
1 control
2 igmp snooping"
::= { activeLineHGUEntry 6 }
activeLineHguDsIgmpControlType OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineHguDsIgmpControlType:
0 transparent(default)
1 strip outer tag
2 add tag
3 replace tag
4 replace only vid
5 add only vid"
::= { activeLineHGUEntry 7 }
activeLineHguDsIgmpVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The HGU downstream igmp and multicast control vid,
should be inputted with <1-4094>."
::= { activeLineHGUEntry 8 }
activeLineHguDsIgmpPri OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vlan priority, should be inputted with <0-7>."
::= { activeLineHGUEntry 9 }
activeLineHguUsIgmpControlType OBJECT-TYPE
SYNTAX INTEGER(0..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineHguUsIgmpControlType:
0 transparent(default)
1 add tag
2 replace tag
3 replace only vid
4 add only vid"
::= { activeLineHGUEntry 10 }
activeLineHguUsIgmpVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The HGU upstream igmp and multicast control vid,
should be inputted with <1-4094>."
::= { activeLineHGUEntry 11 }
activeLineHguUsIgmpPri OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vlan priority, should be inputted with <0-7>."
::= { activeLineHGUEntry 12 }
-- 1.1.3.5.2. activeLineHGUCtrlMcastTable ----------------
activeLineHGUCtrlMcastTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActiveLineHGUCtrlMcastEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"active domain line HGU control multicast table."
::= { activeLineHGUConfig 2 }
activeLineHGUCtrlMcastEntry OBJECT-TYPE
SYNTAX ActiveLineHGUCtrlMcastEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of active line HGU control multicast table"
INDEX { activeLineIndexIX, activeLineHguCtrlMcastIndex }
::= { activeLineHGUCtrlMcastTable 1 }
ActiveLineHGUCtrlMcastEntry ::=
SEQUENCE
{
activeLineIndexIX INTEGER,
activeLineHguCtrlMcastIndex INTEGER,
activeLineHguCtrlMcastAccessType INTEGER,
activeLineHguCtrlMcastVid INTEGER,
activeLineHguCtrlMcastSrcIp IpAddress,
activeLineHguCtrlMcastDstStartIp IpAddress,
activeLineHguCtrlMcastDstEndIp IpAddress,
activeLineHguCtrlMcastGroupBw INTEGER,
activeLineHguCtrlMcastDurationTimes INTEGER,
activeLineHguCtrlMcastNumOfTimes INTEGER,
activeLineHguCtrlMcastTimeInterval INTEGER,
activeLineHguCtrlMcastResetTime INTEGER
}
activeLineIndexIX OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of line primary table, should be inputted with <0-4095>.
The range is not always fit, please see range in commands."
::= { activeLineHGUCtrlMcastEntry 1 }
activeLineHguCtrlMcastIndex OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of HGU control multicast, the 2nd index of this table. Should in <1-16>."
::= { activeLineHGUCtrlMcastEntry 2 }
activeLineHguCtrlMcastAccessType OBJECT-TYPE
SYNTAX INTEGER(0..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeLineHGUCtrlMcastAccessType:
0 del one entry
1 clear all entry
2 add permit entry
3 add preview entry"
::= { activeLineHGUCtrlMcastEntry 3 }
activeLineHguCtrlMcastVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"hgu control multicast vlan id, should be <1-4094>."
::= { activeLineHGUCtrlMcastEntry 4 }
activeLineHguCtrlMcastSrcIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"hgu control multicast source ip address."
::= { activeLineHGUCtrlMcastEntry 5 }
activeLineHguCtrlMcastDstStartIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"hgu control multicast destination start ip address."
::= { activeLineHGUCtrlMcastEntry 6 }
activeLineHguCtrlMcastDstEndIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"hgu control multicast destination end ip address."
::= { activeLineHGUCtrlMcastEntry 7 }
activeLineHguCtrlMcastGroupBw OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"hgu control multicast group bandwidth, should be <x-x>."
::= { activeLineHGUCtrlMcastEntry 8 }
activeLineHguCtrlMcastDurationTimes OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"hgu control multicast duration times, should be <x-x>."
::= { activeLineHGUCtrlMcastEntry 9 }
activeLineHguCtrlMcastNumOfTimes OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"hgu control multicast number of times, should be <x-x>."
::= { activeLineHGUCtrlMcastEntry 10 }
activeLineHguCtrlMcastTimeInterval OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"hgu control multicast time interval, should be <x-x>."
::= { activeLineHGUCtrlMcastEntry 11 }
activeLineHguCtrlMcastResetTime OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"hgu control multicast reset time, should be <x-x>."
::= { activeLineHGUCtrlMcastEntry 12 }
-- 1.1.3.6. activeRuleTable ------------------------------
activeRuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActiveRuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"active domain rule table"
::= { deployActive 6 }
activeRuleEntry OBJECT-TYPE
SYNTAX ActiveRuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of active rule table"
INDEX { activeRuleIndex }
::= { activeRuleTable 1 }
ActiveRuleEntry ::=
SEQUENCE
{
activeRuleIndex INTEGER,
activeRuleDescription OCTET STRING,
activeRuleAction INTEGER,
activeRuleAuthIndex INTEGER,
activeRuleLineIndexesStr OCTET STRING,
activeRuleDefaultLine INTEGER
}
activeRuleIndex OBJECT-TYPE
SYNTAX INTEGER(1..4096)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of rule table, should be inputted with <1-4096>.
The range is not always fit, please see range in commands."
::= { activeRuleEntry 1 }
activeRuleDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"rule description, max length: 128."
::= { activeRuleEntry 2 }
activeRuleAction OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activeRuleAction:
0 permit
1 deny"
::= { activeRuleEntry 3 }
activeRuleAuthIndex OBJECT-TYPE
SYNTAX INTEGER(1..4096)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of rule bind auth, should be inputted with <1-4096>
The range is not always fit, please see range in commands."
::= { activeRuleEntry 4 }
activeRuleLineIndexesStr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"String joined by rule bind line indexes, such as '12,56,1023'.
A rule can at most bind 8 line models."
::= { activeRuleEntry 5 }
activeRuleDefaultLine OBJECT-TYPE
SYNTAX INTEGER(1..4096)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of rule default line, should be inputted with <1-4096>
The range is not always fit, please see range in commands."
::= { activeRuleEntry 6 }
-- 1.1.3.7. activeUniqueConfig --------------------------
activeUniqueConfig OBJECT IDENTIFIER ::= { deployActive 7 }
-- 1.1.3.7.1. activeUniquePrimaryTable
-- 1.1.3.7.2. activeUniqueSipAgentInfoTable
-- 1.1.3.7.3. activeUniqueSipUserAddrTable
-- 1.1.3.7.4. activeUniqueSipUserInfoTable
-- 1.1.3.7.5. activeUniqueSipDigitMapTable
-- 1.1.3.7.1. activeUniquePrimaryTable ------------------
activeUniquePrimaryTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActiveUniquePrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"active domain unique primary table"
::= { activeUniqueConfig 1 }
activeUniquePrimaryEntry OBJECT-TYPE
SYNTAX ActiveUniquePrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of active unique primary table"
INDEX { activeUniqueIndex }
::= { activeUniquePrimaryTable 1 }
ActiveUniquePrimaryEntry ::=
SEQUENCE
{
activeUniqueIndex INTEGER,
activeUniqueDescription OCTET STRING,
activeUniqueSn OCTET STRING
}
activeUniqueIndex OBJECT-TYPE
SYNTAX INTEGER(1..4096)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of unique primary table, should be inputted with <1-4096>.
The range is not always fit, please see range in commands."
::= { activeUniquePrimaryEntry 1 }
activeUniqueDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"unique description, max length: 128."
::= { activeUniquePrimaryEntry 2 }
activeUniqueSn OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"unique sn, string-hex format, max length: 16."
::= { activeUniquePrimaryEntry 3 }
-- 1.1.3.7.2. activeUniqueSipAgentInfoTable --------------
activeUniqueSipAgentInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActiveUniqueSipAgentInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"active domain unique voip sip agent info table"
::= { activeUniqueConfig 2 }
activeUniqueSipAgentInfoEntry OBJECT-TYPE
SYNTAX ActiveUniqueSipAgentInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of active unique voip sip agent info table"
INDEX { activeUniqueIndexI }
::= { activeUniqueSipAgentInfoTable 1 }
ActiveUniqueSipAgentInfoEntry ::=
SEQUENCE
{
activeUniqueIndexI INTEGER,
activeUniqueSipProxyServerIp IpAddress,
activeUniqueSipOutboundProxyIp IpAddress,
activeUniqueSipRegisterServerIp IpAddress,
activeUniqueSipAgentInfoPort INTEGER
}
activeUniqueIndexI OBJECT-TYPE
SYNTAX INTEGER(1..4096)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of unique primary table, should be inputted with <1-4096>.
The range is not always fit, please see range in commands."
::= { activeUniqueSipAgentInfoEntry 1 }
activeUniqueSipProxyServerIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip agent info proxy server ip address."
::= { activeUniqueSipAgentInfoEntry 2 }
activeUniqueSipOutboundProxyIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip agent info outbound proxy ip address."
::= { activeUniqueSipAgentInfoEntry 3 }
activeUniqueSipRegisterServerIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip agent info register server ip address."
::= { activeUniqueSipAgentInfoEntry 4 }
activeUniqueSipAgentInfoPort OBJECT-TYPE
SYNTAX INTEGER(1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip agent info port."
::= { activeUniqueSipAgentInfoEntry 5 }
-- 1.1.3.7.3. activeUniqueSipUserAddrTable --------------
activeUniqueSipUserAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActiveUniqueSipUserAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"active domain unique voip sip user ip address table"
::= { activeUniqueConfig 3 }
activeUniqueSipUserAddrEntry OBJECT-TYPE
SYNTAX ActiveUniqueSipUserAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of active unique voip sip user ip address table"
INDEX { activeUniqueIndexII }
::= { activeUniqueSipUserAddrTable 1 }
ActiveUniqueSipUserAddrEntry ::=
SEQUENCE
{
activeUniqueIndexII INTEGER,
activeUniqueSipuAddressIp IpAddress,
activeUniqueSipuAddressMask IpAddress,
activeUniqueSipuAddressVlan INTEGER,
activeUniqueSipuAddressPri INTEGER
}
activeUniqueIndexII OBJECT-TYPE
SYNTAX INTEGER(1..4096)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of unique primary table, should be inputted with <1-4096>.
The range is not always fit, please see range in commands."
::= { activeUniqueSipUserAddrEntry 1 }
activeUniqueSipuAddressIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip user ip address."
::= { activeUniqueSipUserAddrEntry 2 }
activeUniqueSipuAddressMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip user mask."
::= { activeUniqueSipUserAddrEntry 3 }
activeUniqueSipuAddressVlan OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip user vlan."
::= { activeUniqueSipUserAddrEntry 4 }
activeUniqueSipuAddressPri OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip user priroty."
::= { activeUniqueSipUserAddrEntry 5 }
-- 1.1.3.7.4. activeUniqueSipUserInfoTable --------------
activeUniqueSipUserInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActiveUniqueSipUserInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"active domain unique voip sip user infomation table"
::= { activeUniqueConfig 4 }
activeUniqueSipUserInfoEntry OBJECT-TYPE
SYNTAX ActiveUniqueSipUserInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of unique voip sip user infomation table"
INDEX { activeUniqueIndexIII, activeUniqueSipuInfoIndex }
::= { activeUniqueSipUserInfoTable 1 }
ActiveUniqueSipUserInfoEntry ::=
SEQUENCE
{
activeUniqueIndexIII INTEGER,
activeUniqueSipuInfoIndex INTEGER,
activeUniqueSipuInfoUserName OCTET STRING,
activeUniqueSipuInfoPassword OCTET STRING,
activeUniqueSipuInfoTelephone OCTET STRING
}
activeUniqueIndexIII OBJECT-TYPE
SYNTAX INTEGER(1..4096)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of unique primary table, should be inputted with <1-4096>.
The range is not always fit, please see range in commands."
::= { activeUniqueSipUserInfoEntry 1 }
activeUniqueSipuInfoIndex OBJECT-TYPE
SYNTAX INTEGER(1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of voip sip user info, the 2nd index of this table. Should in <1-2>."
::= { activeUniqueSipUserInfoEntry 2 }
activeUniqueSipuInfoUserName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..25))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip user infomation user name, max length: 25."
::= { activeUniqueSipUserInfoEntry 3 }
activeUniqueSipuInfoPassword OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..25))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip user infomation user name, max length: 25."
::= { activeUniqueSipUserInfoEntry 4 }
activeUniqueSipuInfoTelephone OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..25))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip user infomation user name, max length: 25."
::= { activeUniqueSipUserInfoEntry 5 }
-- 1.1.3.7.5. activeUniqueSipDigitMapTable --------------
activeUniqueSipDigitMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActiveUniqueSipDigitMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"active domain unique voip sip digit map table"
::= { activeUniqueConfig 5 }
activeUniqueSipDigitMapEntry OBJECT-TYPE
SYNTAX ActiveUniqueSipDigitMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of active unique voip sip digit map table"
INDEX { activeUniqueIndexIV, activeUniqueSipdMapIndex }
::= { activeUniqueSipDigitMapTable 1 }
ActiveUniqueSipDigitMapEntry ::=
SEQUENCE
{
activeUniqueIndexIV INTEGER,
activeUniqueSipdMapIndex INTEGER,
activeUniqueSipdMapDialPlanToken OCTET STRING
}
activeUniqueIndexIV OBJECT-TYPE
SYNTAX INTEGER(1..4096)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of unique primary table, should be inputted with <1-4096>.
The range is not always fit, please see range in commands."
::= { activeUniqueSipDigitMapEntry 1 }
activeUniqueSipdMapIndex OBJECT-TYPE
SYNTAX INTEGER(1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of voip digit map, the 2nd index of this table. Should in <1-10>."
::= { activeUniqueSipDigitMapEntry 2 }
activeUniqueSipdMapDialPlanToken OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..28))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip digit map dial plan token, max length: 28."
::= { activeUniqueSipDigitMapEntry 3 }
-- 1.1.4. deployDemo ----------------------------------
deployDemo OBJECT IDENTIFIER ::= { configDevice 4 }
-- 1.1.4.1. demoAuthTable
-- 1.1.4.2. demoDbaTable
-- 1.1.4.3. demoLineCommonConfig
-- 1.1.4.4. demoLineSFUConfig
-- 1.1.4.5. demoLineHGUConfig
-- 1.1.4.6. demoRuleTable
-- 1.1.4.7. demoUniqueConfig
-- 1.1.4.1. demoAuthTable ------------------------------
demoAuthTable OBJECT-TYPE
SYNTAX SEQUENCE OF DemoAuthEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"demo domain auth table"
::= { deployDemo 1 }
demoAuthEntry OBJECT-TYPE
SYNTAX DemoAuthEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of demo auth table"
INDEX { demoAuthIndex }
::= { demoAuthTable 1 }
DemoAuthEntry ::=
SEQUENCE
{
demoAuthIndex INTEGER,
demoAuthDescription OCTET STRING,
demoAuthMode INTEGER,
demoAuthSn OCTET STRING,
demoAuthPw OCTET STRING,
demoAuthLoid OCTET STRING,
demoAuthLopw OCTET STRING,
demoAuthAssignedSlot OCTET STRING,
demoAuthAssignedPport OCTET STRING,
demoAuthAssignedOnt OCTET STRING
}
demoAuthIndex OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of demo auth table, should be inputted with <0-4095>.
The range is not always fit, please see range in commands."
::= { demoAuthEntry 1 }
demoAuthDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"auth description, max length: 128."
::= { demoAuthEntry 2 }
demoAuthMode OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoAuthMode:
0 auth mode sn
1 auth mode pw
2 auth mode sn_pw
3 auth mode loid
4 auth mode lopw
5 auth mode loid_lopw"
::= { demoAuthEntry 3 }
demoAuthSn OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"auth sn, hex string, max length: 16."
::= { demoAuthEntry 4 }
demoAuthPw OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"auth password, hex string, max length: 20."
::= { demoAuthEntry 5 }
demoAuthLoid OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"auth loid, max length: 24."
::= { demoAuthEntry 6 }
demoAuthLopw OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"auth logic password, max length: 12."
::= { demoAuthEntry 7 }
demoAuthAssignedSlot OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"slot id pre assigned."
::= { demoAuthEntry 8 }
demoAuthAssignedPport OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"pon port id pre assigned."
::= { demoAuthEntry 9 }
demoAuthAssignedOnt OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont id pre assigned."
::= { demoAuthEntry 10 }
-- 1.1.4.2. demoDbaTable ------------------------------
demoDbaTable OBJECT-TYPE
SYNTAX SEQUENCE OF DemoDbaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"demo domain dba table"
::= { deployDemo 2 }
demoDbaEntry OBJECT-TYPE
SYNTAX DemoDbaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of demo dba table"
INDEX { demoDbaIndex }
::= { demoDbaTable 1 }
DemoDbaEntry ::=
SEQUENCE
{
demoDbaIndex INTEGER,
demoDbaDescription OCTET STRING,
demoDbaType INTEGER,
demoDbaFixBandwidth INTEGER,
demoDbaAssuredBandwidth INTEGER,
demoDbaMaxBandwidth INTEGER
}
demoDbaIndex OBJECT-TYPE
SYNTAX INTEGER(0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of demo dba table, should be inputted with <0-127>."
::= { demoDbaEntry 1 }
demoDbaDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demo dba description, max length: 128."
::= { demoDbaEntry 2 }
demoDbaType OBJECT-TYPE
SYNTAX INTEGER(1..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoDbaType,
1 fixed bandwidth
2 assured bandwidth
3 assured and max bandwidth
4 max bandwidth
5 fixed and assured and max bandwidth"
::= { demoDbaEntry 3 }
demoDbaFixBandwidth OBJECT-TYPE
SYNTAX INTEGER(128..1310720)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Must to be divisible by 64kbps, must not less than 128 kbps."
::= { demoDbaEntry 4 }
demoDbaAssuredBandwidth OBJECT-TYPE
SYNTAX INTEGER(0..1310592)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Must to be divisible by 64kbps, Can be 0.
If not 0, it must be at least 256 kbps."
::= { demoDbaEntry 5 }
demoDbaMaxBandwidth OBJECT-TYPE
SYNTAX INTEGER(0..1310720)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Must to be divisible by 64kbps, and must not be less than
the sum of assured BW plus fixedBW.
Must less than 1310720 kbps"
::= { demoDbaEntry 6 }
-- 1.1.4.3. demoLineCommonConfig ----------------------
demoLineCommonConfig OBJECT IDENTIFIER ::= { deployDemo 3 }
-- 1.1.4.3.1. demoLinePrimaryTable
-- 1.1.4.3.2. demoLineTcontTable
-- 1.1.4.3.3. demoLineGemportTable
-- 1.1.4.3.4. demoLineFlowmappingTable
-- 1.1.4.3.5. demoLineAttrMgmtTable
-- 1.1.4.3.1. demoLinePrimaryTable --------------------
demoLinePrimaryTable OBJECT-TYPE
SYNTAX SEQUENCE OF DemoLinePrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"demo domain line primary table"
::= { demoLineCommonConfig 1 }
demoLinePrimaryEntry OBJECT-TYPE
SYNTAX DemoLinePrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of demo line primary table"
INDEX { demoLineIndex }
::= { demoLinePrimaryTable 1 }
DemoLinePrimaryEntry ::=
SEQUENCE
{
demoLineIndex INTEGER,
demoLineDeviceType OCTET STRING,
demoLineDescription OCTET STRING,
demoLineTrafficMode INTEGER,
demoLineMappingMode INTEGER
}
demoLineIndex OBJECT-TYPE
SYNTAX INTEGER(0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of line primary table, should be inputted with <0-4095>.
The range is not always fit, please see range in commands."
::= { demoLinePrimaryEntry 1 }
demoLineDeviceType OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(7..7))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineDeviceType:
c30-214 2ETH(1ETH+1iTV)+1POTS SFU
c30-400 4ETH SFU
c30-401 4ETH+WIFI HGU
c30-420 4ETH+2POTS SFU
c30-423 4ETH+2POTS+WIFI+USB HGU
c31-423 4ETH+2POTS+WIFI+USB HGU+SFU
c40-100 1ETH SFU
c40-201 2ETH+WIFI HGU
c40-210 1GE+1FE+1POTS HGU
c40-427 4ETH(3ETH+1iTV)+2POTS+WIFI+USB HGU
d10-423 4ETH+2POTS+WIFI+USB HGU
f10-427 4ETH(3ETH+1iTV)+2POTS+WIFI+USB HGU
h60-100 1ETH SFU
l30-100 1ETH SFU
l30-210 2ETH+1POTS SFU
m50-420 4ETH+2POTS SFU
n20-100 1ETH SFU
n20-400 4ETH SFU
n40-100 1ETH SFU
s10-214 2ETH(1ETH+1iTV)+1POTS HGU
s30-100 1ETH SFU
t10-100 1ETH SFU
t10-214 2ETH(1ETH+1iTV)+1POTS SFU
t10-403 4ETH+WIFI+USB HGU
t10-420 4ETH+2POTS SFU
t10-423 4ETH+2POTS+WIFI+USB HGU
t10-427 4ETH(3ETH+1iTV)+2POTS+WIFI+USB HGU
t60-100 1ETH SFU"
::= { demoLinePrimaryEntry 2 }
demoLineDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"line description, max length: 128."
::= { demoLinePrimaryEntry 3 }
demoLineTrafficMode OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineTrafficMode:
0 pri-queue: priority queue scheduling
1 gem-car: GEM traffic control"
::= { demoLinePrimaryEntry 4 }
demoLineMappingMode OBJECT-TYPE
SYNTAX INTEGER(0..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineMappingMode:
0 vlan
1 priority
2 vlan-priority
3 port
4 port-vlan
5 port-priority
6 port-vlan-priority"
::= { demoLinePrimaryEntry 5 }
-- 1.1.4.3.2. demoLineTcontTable ----------------------
demoLineTcontTable OBJECT-TYPE
SYNTAX SEQUENCE OF DemoLineTcontEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"demo domain line tcont table, now only for tcont bind dba."
::= { demoLineCommonConfig 2 }
demoLineTcontEntry OBJECT-TYPE
SYNTAX DemoLineTcontEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of demo line tcont table"
INDEX { demoLineIndex, demoLineTcontIndex }
::= { demoLineTcontTable 1 }
DemoLineTcontEntry ::=
SEQUENCE
{
demoLineTcontIndex INTEGER,
demoLineTcontDbaIndex INTEGER
}
demoLineTcontIndex OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of tcont, the 2nd index of this table.
Should in <1-8>."
::= { demoLineTcontEntry 1 }
demoLineTcontDbaIndex OBJECT-TYPE
SYNTAX INTEGER(0..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of tcont bind dba, should be inputted with <0-127>."
::= { demoLineTcontEntry 2 }
-- 1.1.4.3.3. demoLineGemportTable --------------------
demoLineGemportTable OBJECT-TYPE
SYNTAX SEQUENCE OF DemoLineGemportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"demo domain line gemport table."
::= { demoLineCommonConfig 3 }
demoLineGemportEntry OBJECT-TYPE
SYNTAX DemoLineGemportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of demo line gemport table"
INDEX { demoLineIndex, demoLineGemportIndex }
::= { demoLineGemportTable 1 }
DemoLineGemportEntry ::=
SEQUENCE
{
demoLineGemportIndex INTEGER,
demoLineGemportSvid INTEGER,
demoLineGemportTcontId INTEGER,
demoLineGemportCir INTEGER,
demoLineGemportPir INTEGER,
demoLineGemportCbs INTEGER,
demoLineGemportPbs INTEGER,
demoLineGemportPq INTEGER
}
demoLineGemportIndex OBJECT-TYPE
SYNTAX INTEGER(1..24)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of gemport, the 2nd index of this table.
Should in <1-24>."
::= { demoLineGemportEntry 1 }
demoLineGemportSvid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The gemport service vlan index, should be inputted with <1-4094>."
::= { demoLineGemportEntry 2 }
demoLineGemportTcontId OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The gemport bind tcont index, should be inputted with <1-8>."
::= { demoLineGemportEntry 3 }
demoLineGemportCir OBJECT-TYPE
SYNTAX INTEGER(64..1310720)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The gemport committed infomation rate, should be inputted with <64-1310720>.
must to be divisible by 64kbps,must not less than 64 kbps."
::= { demoLineGemportEntry 4 }
demoLineGemportPir OBJECT-TYPE
SYNTAX INTEGER(64..1310720)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The gemport peek infomation rate, should be inputted with <64-1310720>.
must to be divisible by 64kbps,must not less than 64 kbps."
::= { demoLineGemportEntry 5 }
demoLineGemportCbs OBJECT-TYPE
SYNTAX INTEGER(2000..1310720)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The gemport committed burst size, should be inputted with <2000-1310720>."
::= { demoLineGemportEntry 6 }
demoLineGemportPbs OBJECT-TYPE
SYNTAX INTEGER(2000..1310720)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The gemport peek burst size, should be inputted with <2000-1310720>."
::= { demoLineGemportEntry 7 }
demoLineGemportPq OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The gemport priority queue, should be inputted with <0-7>."
::= { demoLineGemportEntry 8 }
-- 1.1.4.3.4. demoLineFlowmappingTable ----------------
demoLineFlowmappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF DemoLineFlowmappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"demo domain line flow mapping table."
::= { demoLineCommonConfig 4 }
demoLineFlowmappingEntry OBJECT-TYPE
SYNTAX DemoLineFlowmappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of demo line flow mapping table"
INDEX { demoLineIndex, demoLineFlowmappingIndex }
::= { demoLineFlowmappingTable 1 }
DemoLineFlowmappingEntry ::=
SEQUENCE
{
demoLineFlowmappingIndex INTEGER,
demoLineFlowmappingVid INTEGER,
demoLineFlowmappingPriority INTEGER,
demoLineFlowmappingEthport INTEGER,
demoLineFlowmappingGemport INTEGER,
demoLineFlowmappingType INTEGER
}
demoLineFlowmappingIndex OBJECT-TYPE
SYNTAX INTEGER(1..48)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of flowmapping, the 2nd index of this table. Should in <1-48>.
The range is not always fit, please see range in commands."
::= { demoLineFlowmappingEntry 1 }
demoLineFlowmappingVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The flow mapping vid, should be inputted with <1-4094>."
::= { demoLineFlowmappingEntry 2 }
demoLineFlowmappingPriority OBJECT-TYPE
SYNTAX INTEGER(0..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The flow mapping priority, should be inputted with <0-8>.
Value 8 means don't care 802.1p priority."
::= { demoLineFlowmappingEntry 3 }
demoLineFlowmappingEthport OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The flow mapping ethernet port id, should be inputted with <1-8>."
::= { demoLineFlowmappingEntry 4 }
demoLineFlowmappingGemport OBJECT-TYPE
SYNTAX INTEGER(1..24)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The flow mapping gem port id, should be inputted with <1-24>."
::= { demoLineFlowmappingEntry 5 }
demoLineFlowmappingType OBJECT-TYPE
SYNTAX INTEGER(0..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineFlowmappingType:
0 flowmapping not base port.
1 flowmapping base eth port.
2 flowmapping base veip port.
3. flowmapping base iphost port."
::= { demoLineFlowmappingEntry 6 }
-- 1.1.4.3.5. demoLineAttrMgmtTable --------------------
demoLineAttrMgmtTable OBJECT-TYPE
SYNTAX SEQUENCE OF DemoLineAttrMgmtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"demo domain line attribute management table."
::= { demoLineCommonConfig 5 }
demoLineAttrMgmtEntry OBJECT-TYPE
SYNTAX DemoLineAttrMgmtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of demo line attribute management table"
INDEX { demoLineIndex, demoLineAttrMgmtIndex }
::= { demoLineAttrMgmtTable 1 }
DemoLineAttrMgmtEntry ::=
SEQUENCE
{
demoLineAttrMgmtIndex INTEGER,
demoLineAttrMgmtNport INTEGER,
demoLineAttrMgmtVlanMode INTEGER,
demoLineAttrMgmtNportType INTEGER,
demoLineAttrMgmtEtypeFilter INTEGER,
demoLineAttrMgmtCvlanVid INTEGER,
demoLineAttrMgmtCvlanPri INTEGER,
demoLineAttrMgmtSvlanVid INTEGER,
demoLineAttrMgmtSvlanPri INTEGER
}
demoLineAttrMgmtIndex OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of attribute management, the 2nd index of this table. Should in <1-64>."
::= { demoLineAttrMgmtEntry 1 }
demoLineAttrMgmtNport OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port of attribute management, if eport, should in <1-8>."
::= { demoLineAttrMgmtEntry 2 }
demoLineAttrMgmtVlanMode OBJECT-TYPE
SYNTAX INTEGER(0..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineAttrMgmtVlanMode:
0 transparent
1 tag
2 translation
3 trunk
4 QinQ"
::= { demoLineAttrMgmtEntry 3 }
demoLineAttrMgmtNportType OBJECT-TYPE
SYNTAX INTEGER(1..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineAttrMgmtNportType:
1 eth port in sfu
2 veip port in hgu
3 iphost virtual port, for voip, tdm, etc."
::= { demoLineAttrMgmtEntry 4 }
demoLineAttrMgmtEtypeFilter OBJECT-TYPE
SYNTAX INTEGER(0..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineAttrMgmtEtypeFilter:
0 no filter
1 filter ipoe frame
2 filter pppoe frame
3 filter arp frame"
::= { demoLineAttrMgmtEntry 5 }
demoLineAttrMgmtCvlanVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"cvlan vid, should be inputted with <1-4094>."
::= { demoLineAttrMgmtEntry 6 }
demoLineAttrMgmtCvlanPri OBJECT-TYPE
SYNTAX INTEGER(0..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The cvlan priority, should be inputted with <0-8>.
Value 8 means don't care vlan priority."
::= { demoLineAttrMgmtEntry 7 }
demoLineAttrMgmtSvlanVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"svlan vid, should be inputted with <1-4094>."
::= { demoLineAttrMgmtEntry 8 }
demoLineAttrMgmtSvlanPri OBJECT-TYPE
SYNTAX INTEGER(0..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"svlan priority, should be inputted with <0-8>.
Value 8 means don't care vlan priority."
::= { demoLineAttrMgmtEntry 9 }
-- 1.1.4.4. demoLineSFUConfig --------------------------
demoLineSFUConfig OBJECT IDENTIFIER ::= { deployDemo 4 }
-- 1.1.4.4.1. demoLineSFUTable
-- 1.1.4.4.2. demoLineSFUEthportTable
-- 1.1.4.4.3. demoLineSFUCtrlMcastTable
-- 1.1.4.4.1. demoLineSFUTable ------------------------
demoLineSFUTable OBJECT-TYPE
SYNTAX SEQUENCE OF DemoLineSFUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"demo domain line SFU primary table."
::= { demoLineSFUConfig 1 }
demoLineSFUEntry OBJECT-TYPE
SYNTAX DemoLineSFUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of demo line sfu primary table"
INDEX { demoLineIndex }
::= { demoLineSFUTable 1 }
DemoLineSFUEntry ::=
SEQUENCE
{
demoLineSfuLocalSwitch INTEGER,
demoLineSfuLoopDetectSwitch INTEGER
}
demoLineSfuLocalSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineSfuLocalSwitch:
0 disable(default)
1 enable."
::= { demoLineSFUEntry 1 }
demoLineSfuLoopDetectSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineSfuLoopDetectSwitch:
0 disable(default)
1 enable."
::= { demoLineSFUEntry 2 }
-- 1.1.4.4.2. demoLineSFUEthportTable ------------------
demoLineSFUEthportTable OBJECT-TYPE
SYNTAX SEQUENCE OF DemoLineSFUEthportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"demo domain line SFU ethernet port table."
::= { demoLineSFUConfig 2 }
demoLineSFUEthportEntry OBJECT-TYPE
SYNTAX DemoLineSFUEthportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of demo line SFU ethernet port table"
INDEX { demoLineIndex, demoLineSfuEthportIndex }
::= { demoLineSFUEthportTable 1 }
DemoLineSFUEthportEntry ::=
SEQUENCE
{
demoLineSfuEthportIndex INTEGER,
demoLineSfuEthportSwitch INTEGER,
demoLineSfuEthportFlowCtrlSwitch INTEGER,
demoLineSfuEthportLoopbackSwitch INTEGER,
demoLineSfuEthportBwEgress INTEGER,
demoLineSfuEthportFastLeaveSwitch INTEGER,
demoLineSfuEthportMaxGroups INTEGER,
demoLineSfuEthportMaxMacCount INTEGER,
demoLineSfuEthportMcastMode INTEGER,
demoLineSfuEthportDsIgmpControlType INTEGER,
demoLineSfuEthportDsIgmpVid INTEGER,
demoLineSfuEthportDsIgmpPri INTEGER,
demoLineSfuEthportUsIgmpControlType INTEGER,
demoLineSfuEthportUsIgmpVid INTEGER,
demoLineSfuEthportUsIgmpPri INTEGER
}
demoLineSfuEthportIndex OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of SFU ethernet port, the 2nd index of this table. Should in <1-8>."
::= { demoLineSFUEthportEntry 1 }
demoLineSfuEthportSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineSfuEthportSwitch:
0 no shutdown(default)
1 shutdown"
::= { demoLineSFUEthportEntry 2 }
demoLineSfuEthportFlowCtrlSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineSfuEthportFlowCtrlSwitch:
0 disable(default)
1 enable"
::= { demoLineSFUEthportEntry 3 }
demoLineSfuEthportLoopbackSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineSfuEthportLoopbackSwitch:
0 disable(default)
1 enable"
::= { demoLineSFUEthportEntry 4 }
demoLineSfuEthportBwEgress OBJECT-TYPE
SYNTAX INTEGER(64..1023936)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SFU ethernet port max bandwidth egress, should be inputted with <64-1023936>."
::= { demoLineSFUEthportEntry 5 }
demoLineSfuEthportFastLeaveSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineSfuEthportFastLeaveSwitch:
0 disable(default)
1 enable"
::= { demoLineSFUEthportEntry 6 }
demoLineSfuEthportMaxGroups OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SFU ethernet port max igmp groups, should be inputted with <1-128>."
::= { demoLineSFUEthportEntry 7 }
demoLineSfuEthportMaxMacCount OBJECT-TYPE
SYNTAX INTEGER(1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SFU ethernet port max mac address count, should be inputted with <1-255>."
::= { demoLineSFUEthportEntry 8 }
demoLineSfuEthportMcastMode OBJECT-TYPE
SYNTAX INTEGER(0..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineSfuEthportMcastMode(some ont not support):
0 unconcern(default)
1 control
2 igmp snooping"
::= { demoLineSFUEthportEntry 9 }
demoLineSfuEthportDsIgmpControlType OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineSfuEthportDsIgmpControlType:
0 transparent(default)
1 strip outer tag
2 add tag
3 replace tag
4 replace only vid
5 add only vid"
::= { demoLineSFUEthportEntry 10 }
demoLineSfuEthportDsIgmpVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SFU ethernet port downstream igmp and multicast control vid,
should be inputted with <1-4094>."
::= { demoLineSFUEthportEntry 11 }
demoLineSfuEthportDsIgmpPri OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vlan priority, should be inputted with <0-7>."
::= { demoLineSFUEthportEntry 12 }
demoLineSfuEthportUsIgmpControlType OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineSfuEthportUsIgmpControlType:
0 transparent(default)
1 strip outer tag
2 add tag
3 replace tag
4 replace only vid
5 add only vid"
::= { demoLineSFUEthportEntry 13 }
demoLineSfuEthportUsIgmpVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SFU ethernet port upstream igmp and multicast control vid,
should be inputted with <1-4094>."
::= { demoLineSFUEthportEntry 14 }
demoLineSfuEthportUsIgmpPri OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vlan priority, should be inputted with <0-7>."
::= { demoLineSFUEthportEntry 15 }
-- 1.1.4.4.3. demoLineSFUCtrlMcastTable ----------------
demoLineSFUCtrlMcastTable OBJECT-TYPE
SYNTAX SEQUENCE OF DemoLineSFUCtrlMcastEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"demo domain line SFU ethernet port control multicast table."
::= { demoLineSFUConfig 3 }
demoLineSFUCtrlMcastEntry OBJECT-TYPE
SYNTAX DemoLineSFUCtrlMcastEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of demo line SFU ethernet port control multicast table"
INDEX { demoLineIndex, demoLineSfuEthportIndex, demoLineSfuCtrlMcastIndex }
::= { demoLineSFUCtrlMcastTable 1 }
DemoLineSFUCtrlMcastEntry ::=
SEQUENCE
{
demoLineSfuCtrlMcastIndex INTEGER,
demoLineSfuCtrlMcastAccessType INTEGER,
demoLineSfuCtrlMcastVid INTEGER,
demoLineSfuCtrlMcastSrcIp IpAddress,
demoLineSfuCtrlMcastDstStartIp IpAddress,
demoLineSfuCtrlMcastDstEndIp IpAddress,
demoLineSfuCtrlMcastGroupBw INTEGER,
demoLineSfuCtrlMcastDurationTimes INTEGER,
demoLineSfuCtrlMcastNumOfTimes INTEGER,
demoLineSfuCtrlMcastTimeInterval INTEGER,
demoLineSfuCtrlMcastResetTime INTEGER
}
demoLineSfuCtrlMcastIndex OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of SFU ethernet port control multicast, the 3rd index of this table. Should in <1-16>."
::= { demoLineSFUCtrlMcastEntry 1 }
demoLineSfuCtrlMcastAccessType OBJECT-TYPE
SYNTAX INTEGER(0..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineSfuCtrlMcastAccessType:
0 del one entry
1 clear all entry
2 add permit entry
3 add preview entry"
::= { demoLineSFUCtrlMcastEntry 2 }
demoLineSfuCtrlMcastVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfu control multicast vlan id, should be <1-4094>."
::= { demoLineSFUCtrlMcastEntry 3 }
demoLineSfuCtrlMcastSrcIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfu control multicast source ip address."
::= { demoLineSFUCtrlMcastEntry 4 }
demoLineSfuCtrlMcastDstStartIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfu control multicast destination start ip address."
::= { demoLineSFUCtrlMcastEntry 5 }
demoLineSfuCtrlMcastDstEndIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfu control multicast destination end ip address."
::= { demoLineSFUCtrlMcastEntry 6 }
demoLineSfuCtrlMcastGroupBw OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfu control multicast group bandwidth, should be <x-x>."
::= { demoLineSFUCtrlMcastEntry 7 }
demoLineSfuCtrlMcastDurationTimes OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfu control multicast duration times, should be <x-x>."
::= { demoLineSFUCtrlMcastEntry 8 }
demoLineSfuCtrlMcastNumOfTimes OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfu control multicast number of times, should be <x-x>."
::= { demoLineSFUCtrlMcastEntry 9 }
demoLineSfuCtrlMcastTimeInterval OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfu control multicast time interval, should be <x-x>."
::= { demoLineSFUCtrlMcastEntry 10 }
demoLineSfuCtrlMcastResetTime OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfu control multicast reset time, should be <x-x>."
::= { demoLineSFUCtrlMcastEntry 11 }
-- 1.1.4.5. demoLineHGUConfig --------------------------
demoLineHGUConfig OBJECT IDENTIFIER ::= { deployDemo 5 }
-- 1.1.4.5.1. demoLineHGUTable
-- 1.1.4.5.2. demoLineHGUCtrlMcastTable
-- 1.1.4.5.1. demoLineHGUTable ------------------------
demoLineHGUTable OBJECT-TYPE
SYNTAX SEQUENCE OF DemoLineHGUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"demo domain line HGU table."
::= { demoLineHGUConfig 1 }
demoLineHGUEntry OBJECT-TYPE
SYNTAX DemoLineHGUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of demo line HGU table"
INDEX { demoLineIndex }
::= { demoLineHGUTable 1 }
DemoLineHGUEntry ::=
SEQUENCE
{
demoLineHguSwitch INTEGER,
demoLineHguFastLeaveSwitch INTEGER,
demoLineHguMaxGroups INTEGER,
demoLineHguMaxMacCount INTEGER,
demoLineHguMcastMode INTEGER,
demoLineHguDsIgmpControlType INTEGER,
demoLineHguDsIgmpVid INTEGER,
demoLineHguDsIgmpPri INTEGER,
demoLineHguUsIgmpControlType INTEGER,
demoLineHguUsIgmpVid INTEGER,
demoLineHguUsIgmpPri INTEGER
}
demoLineHguSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineHguSwitch:
0 no shutdown(default)
1 shutdown"
::= { demoLineHGUEntry 1 }
demoLineHguFastLeaveSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineHguFlowCtrlSwitch:
0 disable(default)
1 enable"
::= { demoLineHGUEntry 2 }
demoLineHguMaxGroups OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The HGU max igmp groups, should be inputted with <1-128>."
::= { demoLineHGUEntry 3 }
demoLineHguMaxMacCount OBJECT-TYPE
SYNTAX INTEGER(1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The HGU max mac address count, should be inputted with <1-255>."
::= { demoLineHGUEntry 4 }
demoLineHguMcastMode OBJECT-TYPE
SYNTAX INTEGER(0..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineHguMcastMode(some ont not support):
0 unconcern(default)
1 control
2 igmp snooping"
::= { demoLineHGUEntry 5 }
demoLineHguDsIgmpControlType OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineHguDsIgmpControlType:
0 transparent(default)
1 strip outer tag
2 add tag
3 replace tag
4 replace only vid
5 add only vid"
::= { demoLineHGUEntry 6 }
demoLineHguDsIgmpVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The HGU downstream igmp and multicast control vid,
should be inputted with <1-4094>."
::= { demoLineHGUEntry 7 }
demoLineHguDsIgmpPri OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vlan priority, should be inputted with <0-7>."
::= { demoLineHGUEntry 8 }
demoLineHguUsIgmpControlType OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineHguUsIgmpControlType:
0 transparent(default)
1 strip outer tag
2 add tag
3 replace tag
4 replace only vid
5 add only vid"
::= { demoLineHGUEntry 9 }
demoLineHguUsIgmpVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The HGU upstream igmp and multicast control vid,
should be inputted with <1-4094>."
::= { demoLineHGUEntry 10 }
demoLineHguUsIgmpPri OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vlan priority, should be inputted with <0-7>."
::= { demoLineHGUEntry 11 }
-- 1.1.4.5.2. demoLineHGUCtrlMcastTable ----------------
demoLineHGUCtrlMcastTable OBJECT-TYPE
SYNTAX SEQUENCE OF DemoLineHGUCtrlMcastEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"demo domain line HGU control multicast table."
::= { demoLineHGUConfig 2 }
demoLineHGUCtrlMcastEntry OBJECT-TYPE
SYNTAX DemoLineHGUCtrlMcastEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of demo line HGU control multicast table"
INDEX { demoLineIndex, demoLineHguCtrlMcastIndex }
::= { demoLineHGUCtrlMcastTable 1 }
DemoLineHGUCtrlMcastEntry ::=
SEQUENCE
{
demoLineHguCtrlMcastIndex INTEGER,
demoLineHguCtrlMcastAccessType INTEGER,
demoLineHguCtrlMcastVid INTEGER,
demoLineHguCtrlMcastSrcIp IpAddress,
demoLineHguCtrlMcastDstStartIp IpAddress,
demoLineHguCtrlMcastDstEndIp IpAddress,
demoLineHguCtrlMcastGroupBw INTEGER,
demoLineHguCtrlMcastDurationTimes INTEGER,
demoLineHguCtrlMcastNumOfTimes INTEGER,
demoLineHguCtrlMcastTimeInterval INTEGER,
demoLineHguCtrlMcastResetTime INTEGER
}
demoLineHguCtrlMcastIndex OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of HGU control multicast, the 2nd index of this table. Should in <1-16>."
::= { demoLineHGUCtrlMcastEntry 1 }
demoLineHguCtrlMcastAccessType OBJECT-TYPE
SYNTAX INTEGER(0..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoLineHGUCtrlMcastAccessType:
0 del one entry
1 clear all entry
2 add permit entry
3 add preview entry"
::= { demoLineHGUCtrlMcastEntry 2 }
demoLineHguCtrlMcastVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"hgu control multicast vlan id, should be <1-4094>."
::= { demoLineHGUCtrlMcastEntry 3 }
demoLineHguCtrlMcastSrcIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"hgu control multicast source ip address."
::= { demoLineHGUCtrlMcastEntry 4 }
demoLineHguCtrlMcastDstStartIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"hgu control multicast destination start ip address."
::= { demoLineHGUCtrlMcastEntry 5 }
demoLineHguCtrlMcastDstEndIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"hgu control multicast destination end ip address."
::= { demoLineHGUCtrlMcastEntry 6 }
demoLineHguCtrlMcastGroupBw OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"hgu control multicast group bandwidth, should be <x-x>."
::= { demoLineHGUCtrlMcastEntry 7 }
demoLineHguCtrlMcastDurationTimes OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"hgu control multicast duration times, should be <x-x>."
::= { demoLineHGUCtrlMcastEntry 8 }
demoLineHguCtrlMcastNumOfTimes OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"hgu control multicast number of times, should be <x-x>."
::= { demoLineHGUCtrlMcastEntry 9 }
demoLineHguCtrlMcastTimeInterval OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"hgu control multicast time interval, should be <x-x>."
::= { demoLineHGUCtrlMcastEntry 10 }
demoLineHguCtrlMcastResetTime OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"hgu control multicast reset time, should be <x-x>."
::= { demoLineHGUCtrlMcastEntry 11 }
-- 1.1.4.6. demoRuleTable ------------------------------
demoRuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF DemoRuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"demo domain rule table"
::= { deployDemo 6 }
demoRuleEntry OBJECT-TYPE
SYNTAX DemoRuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of demo rule table"
INDEX { demoRuleIndex }
::= { demoRuleTable 1 }
DemoRuleEntry ::=
SEQUENCE
{
demoRuleIndex INTEGER,
demoRuleDescription OCTET STRING,
demoRuleAction INTEGER,
demoRuleAuthIndex INTEGER,
demoRuleLineIndexesStr OCTET STRING
}
demoRuleIndex OBJECT-TYPE
SYNTAX INTEGER(1..4096)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of rule table, should be inputted with <1-4096>.
The range is not always fit, please see range in commands."
::= { demoRuleEntry 1 }
demoRuleDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"rule description, max length: 128."
::= { demoRuleEntry 2 }
demoRuleAction OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"demoRuleAction:
0 permit
1 deny"
::= { demoRuleEntry 3 }
demoRuleAuthIndex OBJECT-TYPE
SYNTAX INTEGER(1..4096)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of rule bind auth, should be inputted with <1-4096>
The range is not always fit, please see range in commands."
::= { demoRuleEntry 4 }
demoRuleLineIndexesStr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"String joined by rule bind line indexes, such as '12,56,1023'.
A rule can at most bind 8 line models."
::= { demoRuleEntry 5 }
-- 1.1.4.7. demoUniqueConfig --------------------------
demoUniqueConfig OBJECT IDENTIFIER ::= { deployDemo 7 }
-- 1.1.4.7.1. demoUniquePrimaryTable
-- 1.1.4.7.2. demoUniqueSipAgentInfoTable
-- 1.1.4.7.3. demoUniqueSipUserAddrTable
-- 1.1.4.7.4. demoUniqueSipUserInfoTable
-- 1.1.4.7.5. demoUniqueSipDigitMapTable
-- 1.1.4.7.1. demoUniquePrimaryTable ------------------
demoUniquePrimaryTable OBJECT-TYPE
SYNTAX SEQUENCE OF DemoUniquePrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"demo domain unique primary table"
::= { demoUniqueConfig 1 }
demoUniquePrimaryEntry OBJECT-TYPE
SYNTAX DemoUniquePrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of demo unique primary table"
INDEX { demoUniqueIndex }
::= { demoUniquePrimaryTable 1 }
DemoUniquePrimaryEntry ::=
SEQUENCE
{
demoUniqueIndex INTEGER,
demoUniqueDescription OCTET STRING,
demoUniqueSn OCTET STRING
}
demoUniqueIndex OBJECT-TYPE
SYNTAX INTEGER(1..4096)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of unique primary table, should be inputted with <1-4096>.
The range is not always fit, please see range in commands."
::= { demoUniquePrimaryEntry 1 }
demoUniqueDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"unique description, max length: 128."
::= { demoUniquePrimaryEntry 2 }
demoUniqueSn OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"unique sn, hex format, max length: 16."
::= { demoUniquePrimaryEntry 3 }
-- 1.1.4.7.2. demoUniqueSipAgentInfoTable --------------
demoUniqueSipAgentInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF DemoUniqueSipAgentInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"demo domain unique voip sip agent info table"
::= { demoUniqueConfig 2 }
demoUniqueSipAgentInfoEntry OBJECT-TYPE
SYNTAX DemoUniqueSipAgentInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of demo unique voip sip agent info table"
INDEX { demoUniqueIndex }
::= { demoUniqueSipAgentInfoTable 1 }
DemoUniqueSipAgentInfoEntry ::=
SEQUENCE
{
demoUniqueSipProxyServerIp IpAddress,
demoUniqueSipOutboundProxyIp IpAddress,
demoUniqueSipRegisterServerIp IpAddress,
demoUniqueSipAgentInfoPort INTEGER
}
demoUniqueSipProxyServerIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip agent info proxy server ip address."
::= { demoUniqueSipAgentInfoEntry 1 }
demoUniqueSipOutboundProxyIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip agent info outbound proxy ip address."
::= { demoUniqueSipAgentInfoEntry 2 }
demoUniqueSipRegisterServerIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip agent info register server ip address."
::= { demoUniqueSipAgentInfoEntry 3 }
demoUniqueSipAgentInfoPort OBJECT-TYPE
SYNTAX INTEGER(1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip agent info port."
::= { demoUniqueSipAgentInfoEntry 4 }
-- 1.1.4.7.3. demoUniqueSipUserAddrTable --------------
demoUniqueSipUserAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF DemoUniqueSipUserAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"demo domain unique voip sip user ip address table"
::= { demoUniqueConfig 3 }
demoUniqueSipUserAddrEntry OBJECT-TYPE
SYNTAX DemoUniqueSipUserAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of demo unique voip sip user ip address table"
INDEX { demoUniqueIndex }
::= { demoUniqueSipUserAddrTable 1 }
DemoUniqueSipUserAddrEntry ::=
SEQUENCE
{
demoUniqueSipuAddressIp IpAddress,
demoUniqueSipuAddressMask IpAddress,
demoUniqueSipuAddressVlan INTEGER
}
demoUniqueSipuAddressIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip user ip address."
::= { demoUniqueSipUserAddrEntry 1 }
demoUniqueSipuAddressMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip user mask."
::= { demoUniqueSipUserAddrEntry 2 }
demoUniqueSipuAddressVlan OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip user vlan."
::= { demoUniqueSipUserAddrEntry 3 }
-- 1.1.4.7.4. demoUniqueSipUserInfoTable --------------
demoUniqueSipUserInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF DemoUniqueSipUserInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"demo domain unique voip sip user infomation table"
::= { demoUniqueConfig 4 }
demoUniqueSipUserInfoEntry OBJECT-TYPE
SYNTAX DemoUniqueSipUserInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of unique voip sip user infomation table"
INDEX { demoUniqueIndex, demoUniqueSipuInfoIndex }
::= { demoUniqueSipUserInfoTable 1 }
DemoUniqueSipUserInfoEntry ::=
SEQUENCE
{
demoUniqueSipuInfoIndex INTEGER,
demoUniqueSipuInfoUserName OCTET STRING,
demoUniqueSipuInfoPassword OCTET STRING,
demoUniqueSipuInfoTelephone OCTET STRING
}
demoUniqueSipuInfoIndex OBJECT-TYPE
SYNTAX INTEGER(1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of voip sip user info, the 2nd index of this table. Should in <1-2>."
::= { demoUniqueSipUserInfoEntry 1 }
demoUniqueSipuInfoUserName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..25))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip user infomation user name, max length: 25."
::= { demoUniqueSipUserInfoEntry 2 }
demoUniqueSipuInfoPassword OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..25))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip user infomation user name, max length: 25."
::= { demoUniqueSipUserInfoEntry 3 }
demoUniqueSipuInfoTelephone OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..25))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip user infomation user name, max length: 25."
::= { demoUniqueSipUserInfoEntry 4 }
-- 1.1.4.7.5. demoUniqueSipDigitMapTable --------------
demoUniqueSipDigitMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF DemoUniqueSipDigitMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"demo domain unique voip sip digit map table"
::= { demoUniqueConfig 5 }
demoUniqueSipDigitMapEntry OBJECT-TYPE
SYNTAX DemoUniqueSipDigitMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of demo unique voip sip digit map table"
INDEX { demoUniqueIndex, demoUniqueSipdMapIndex }
::= { demoUniqueSipDigitMapTable 1 }
DemoUniqueSipDigitMapEntry ::=
SEQUENCE
{
demoUniqueSipdMapIndex INTEGER,
demoUniqueSipdMapDialPlanToken OCTET STRING
}
demoUniqueSipdMapIndex OBJECT-TYPE
SYNTAX INTEGER(1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of voip digit map, the 2nd index of this table. Should in <1-10>."
::= { demoUniqueSipDigitMapEntry 1 }
demoUniqueSipdMapDialPlanToken OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..28))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voip sip digit map dial plan token, max length: 28."
::= { demoUniqueSipDigitMapEntry 2 }
-- 1.1.5. configDeviceBaseInfo ----------------------------
configDeviceBaseInfo OBJECT IDENTIFIER ::= { configDevice 5 }
idleTimeout OBJECT-TYPE
SYNTAX INTEGER(0..480)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"system idle timout, unit is minute."
::= { configDeviceBaseInfo 1 }
loggingDisplaySwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"loggingDisplaySwitch:
0 off(default)
1 on"
::= { configDeviceBaseInfo 2 }
ontLoggingDisplaySwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ontLoggingDisplaySwitch:
0 off(default)
1 on."
::= { configDeviceBaseInfo 3 }
ponSwitchTable OBJECT-TYPE
SYNTAX SEQUENCE OF PonSwitchEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"pon switch table."
::= { configDeviceBaseInfo 4 }
ponSwitchEntry OBJECT-TYPE
SYNTAX PonSwitchEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of pon switch table"
INDEX { ponSwitchVlanIndex }
::= { ponSwitchTable 1 }
PonSwitchEntry ::=
SEQUENCE
{
ponSwitchVlanIndex INTEGER,
ponSwitchEnable INTEGER,
ponSwitchRowStatus RowStatus
}
ponSwitchVlanIndex OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of this table, should be inputted with <1-4094>.
The range is not always fit, please see range in commands."
::= { ponSwitchEntry 1 }
ponSwitchEnable OBJECT-TYPE
SYNTAX INTEGER(1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1 -- enable pon-switch."
::= { ponSwitchEntry 2 }
ponSwitchRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { ponSwitchEntry 3 }
deactiveOntIdList OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"deactive ont id list, such as 0/8/1-0/8/10,0/10/10"
::= { configDeviceBaseInfo 5 }
-- 1.1.6. configEdfa --------------------------------------
configEdfa OBJECT IDENTIFIER ::= { configDevice 6 }
-- fixme: <20><>֪<EFBFBD><D6AA><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>С<EFBFBD><D0A1><EFBFBD>ģ<EFBFBD><C4A3><EFBFBD>ͳһ<CDB3><D2BB><EFBFBD><EFBFBD><EFBFBD>ַ<EFBFBD><D6B7><EFBFBD><EFBFBD><EFBFBD>ʽ<EFBFBD><CABD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>н<EFBFBD><D0BD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>Ҫ<EFBFBD>ĸ<EFBFBD>ʽ<EFBFBD><CABD>
edfaInternalTemperature OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"edfa internal temperature, unit is <20><>."
::= { configEdfa 1 }
edfaInputPower1 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"edfa input power1, unit is dBm."
::= { configEdfa 2 }
edfaInputPower2 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"edfa input power2, unit is dBm."
::= { configEdfa 3 }
edfaActualOutputPower OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"edfa actual output power, unit is dBm."
::= { configEdfa 4 }
edfaOutputAttenuator OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"edfa setting output attenuator, unit is dBm.
range is -0.5 to 3."
::= { configEdfa 5 }
edfaSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"edfa serial number."
::= { configEdfa 6 }
edfaPumpBias1 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"edfa pump bias, unit is A."
::= { configEdfa 7 }
edfaPumpTemperature1 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"edfa pump temperature, unit is <20><>."
::= { configEdfa 8 }
edfaPumpTec1 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"edfa pump temperature control current, unit is A."
::= { configEdfa 9 }
edfaPumpBias2 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"edfa pump bias, unit is A."
::= { configEdfa 10 }
edfaPumpTemperature2 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"edfa pump temperature, unit is <20><>."
::= { configEdfa 11 }
edfaPumpTec2 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"edfa pump temperature control current, unit is A."
::= { configEdfa 12 }
edfaPowerVoltage OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"edfa power voltage, unit is V."
::= { configEdfa 13 }
edfaHostname OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"edfa name of equipment."
::= { configEdfa 14 }
edfaReset OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set edfaReset = 1 to reset all parameter."
::= { configEdfa 15 }
--------------------------------------------------------------
------------------ 1.2. config slot ------------------------
--------------------------------------------------------------
--------------------------------------------------------------
------------------ 1.3. config pport ----------------------
--------------------------------------------------------------
-- 1.3.1. ontFindConfigTable
-- 1.3.2. ontSilentConfigTable
-- 1.3.3. configPportPrimaryTable
-- 1.3.4. configPportFecTable
-- 1.3.1. ontFindConfigTable ------------------------------
ontFindConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntFindConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont find config table"
::= { configPport 1 }
ontFindConfigEntry OBJECT-TYPE
SYNTAX OntFindConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont find config table"
INDEX { cpSlotIndex, cpPportIndex }
::= { ontFindConfigTable 1 }
OntFindConfigEntry ::=
SEQUENCE
{
cpSlotIndex INTEGER,
cpPportIndex INTEGER,
ontFindConfigEnable INTEGER,
ontFindConfigInterval INTEGER,
ontFindConfigAgeEnable INTEGER,
ontFindConfigAgingTime INTEGER,
ontFindConfigMinDistance INTEGER,
ontFindConfigMaxDistance INTEGER,
ontFindDistanceRowStatus RowStatus
}
cpSlotIndex OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"slot index, range <0-5>."
::= { ontFindConfigEntry 1 }
cpPportIndex OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"pon port index, range <1-16>."
::= { ontFindConfigEntry 2 }
ontFindConfigEnable OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ontFindConfigEnable:
0 disable
1 enable"
::= { ontFindConfigEntry 3 }
ontFindConfigInterval OBJECT-TYPE
SYNTAX INTEGER(3..30)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ont find interval time,range <3-30> seconds."
::= { ontFindConfigEntry 4 }
ontFindConfigAgeEnable OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ontFindConfigAgeEnable:
0 disable
1 enable"
::= { ontFindConfigEntry 5 }
ontFindConfigAgingTime OBJECT-TYPE
SYNTAX INTEGER(1..86400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ont find list aging time,range <1-86400> seconds."
::= { ontFindConfigEntry 6 }
ontFindConfigMinDistance OBJECT-TYPE
SYNTAX INTEGER(0..40)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ont find min distance,range <0-40> km."
::= { ontFindConfigEntry 7 }
ontFindConfigMaxDistance OBJECT-TYPE
SYNTAX INTEGER(0..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ont find min distance,range <0-60> km."
::= { ontFindConfigEntry 8 }
ontFindDistanceRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { ontFindConfigEntry 9 }
-- 1.3.2. ontSilentConfigTable ----------------------------
ontSilentConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntSilentConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont silent config table"
::= { configPport 2 }
ontSilentConfigEntry OBJECT-TYPE
SYNTAX OntSilentConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont silent config table"
INDEX { cpSlotIndexI, cpPportIndexI }
::= { ontSilentConfigTable 1 }
OntSilentConfigEntry ::=
SEQUENCE
{
cpSlotIndexI INTEGER,
cpPportIndexI INTEGER,
ontSilentConfigAuthFailEnable INTEGER,
ontSilentConfigAuthFailTime INTEGER,
ontSilentConfigOfflineEnable INTEGER,
ontSilentConfigOfflineTime INTEGER
}
cpSlotIndexI OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"slot index, range <0-5>."
::= { ontSilentConfigEntry 1 }
cpPportIndexI OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"pon port index, range <1-16>."
::= { ontSilentConfigEntry 2 }
ontSilentConfigAuthFailEnable OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ontSilentConfigAuthFailEnable:
0 disable
1 enable"
::= { ontSilentConfigEntry 3 }
ontSilentConfigAuthFailTime OBJECT-TYPE
SYNTAX INTEGER(1..86400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ont silent auth fail silence time, range <1-86400> seconds."
::= { ontSilentConfigEntry 4 }
ontSilentConfigOfflineEnable OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ontSilentConfigOfflineEnable:
0 disable
1 enable"
::= { ontSilentConfigEntry 5 }
ontSilentConfigOfflineTime OBJECT-TYPE
SYNTAX INTEGER(1..86400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ont silent offline silence time, range <1-86400> seconds."
::= { ontSilentConfigEntry 6 }
-- config pport primary table ------------------------------------
configPportPrimaryTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConfigPportPrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"status pport primary table"
::= { configPport 3 }
configPportPrimaryEntry OBJECT-TYPE
SYNTAX ConfigPportPrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont find list table"
INDEX { cpSlotIndexII, cpPportIndexII }
::= { configPportPrimaryTable 1 }
ConfigPportPrimaryEntry ::=
SEQUENCE
{
cpSlotIndexII INTEGER,
cpPportIndexII INTEGER,
pportAdminStatus INTEGER,
pportLaserEnable INTEGER
}
cpSlotIndexII OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { configPportPrimaryEntry 1 }
cpPportIndexII OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { configPportPrimaryEntry 2 }
pportAdminStatus OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"pportAdminStatus:
0 shutdown
1 no shutdown(default)"
::= { configPportPrimaryEntry 3 }
pportLaserEnable OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"pportLaserEnable:
0 disable
1 enable(default)"
::= { configPportPrimaryEntry 4 }
-- config pport fec table ------------------------------------
configPportFecTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConfigPportFecEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"config pon port fec table"
::= { configPport 4 }
configPportFecEntry OBJECT-TYPE
SYNTAX ConfigPportFecEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of pon port fec table"
INDEX { cpSlotIndexII, cpPportIndexII }
::= { configPportFecTable 1 }
ConfigPportFecEntry ::=
SEQUENCE
{
cpSlotIndexIII INTEGER,
cpPportIndexIII INTEGER,
pportFecStatus INTEGER
}
cpSlotIndexIII OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { configPportFecEntry 1 }
cpPportIndexIII OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { configPportFecEntry 2 }
pportFecStatus OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"pportFecStatus:
0 disable(default)
1 enable"
::= { configPportFecEntry 3 }
--------------------------------------------------------------
------------------ 1.4. config ont ------------------------
--------------------------------------------------------------
-- 1.4.1. ontManageTable
-- 1.4.2. ontUpgradeTable
-- 1.4.3. ontPortTable
-- 1.4.1. ontManageTable ----------------------------------
ontManageTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntManageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont management table, such as reboot, ont statistics ethport switch, etc."
::= { configOnt 1 }
ontManageEntry OBJECT-TYPE
SYNTAX OntManageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont silent config table"
INDEX { coSlotIndex, coPportIndex, coOntOnlineIndex }
::= { ontManageTable 1 }
OntManageEntry ::=
SEQUENCE
{
coSlotIndex INTEGER,
coPportIndex INTEGER,
coOntOnlineIndex INTEGER,
ontStatisticsEth INTEGER,
ontStatisticsGem INTEGER,
ontReboot INTEGER,
ontAdminState INTEGER,
ontFactorySet INTEGER,
protocolPort80 INTEGER,
restoreFactory INTEGER
}
coSlotIndex OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontManageEntry 1 }
coPportIndex OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontManageEntry 2 }
coOntOnlineIndex OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ont online index, the 3rd index of this table. range is <1-128>"
::= { ontManageEntry 3 }
ontStatisticsEth OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ontStatisticsEth:
0 disable(default)
1 enable."
::= { ontManageEntry 4 }
ontStatisticsGem OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ontStatisticsGem:
0 disable(default)
1 enable"
::= { ontManageEntry 5 }
ontReboot OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set ontReboot=1 to reboot the ont, when read, always 0."
::= { ontManageEntry 6 }
ontAdminState OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ontAdminState:
0 deactive
1 active(default)"
::= { ontManageEntry 7 }
ontFactorySet OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set ontFactorySet=1 to factory setting the ont, when read, always 0."
::= { ontManageEntry 8 }
protocolPort80 OBJECT-TYPE
SYNTAX INTEGER { disable_discard(0),
disable_forward(1),
enable_discard(2),
enable_forward(3),
init(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set protocol-port-80 disable mode discard or enable mode forward."
::= { ontManageEntry 9 }
restoreFactory OBJECT-TYPE
SYNTAX INTEGER { wan(0),
wifi(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"factory setting restore.
0: wan
1: wifi"
::= { ontManageEntry 10 }
-- 1.4.2. ontUpgradeTable ----------------------------------
ontUpgradeTable OBJECT-IDENTITY
STATUS current
DESCRIPTION
"ont upgrade table"
::= { configOnt 2 }
ontUpgradeEntry OBJECT IDENTIFIER ::= { ontUpgradeTable 1 }
OntUpgradeEntry ::=
SEQUENCE
{
ontUpgradeIdList OCTET STRING,
ontUpgradeSn OCTET STRING,
ontUpgradeParams INTEGER,
ontUpgradeRowStatus RowStatus
}
ontUpgradeIdList OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ont upgrade ont-id list."
::= { ontUpgradeEntry 1 }
ontUpgradeSn OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..8))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ont upgrade ont sn."
::= { ontUpgradeEntry 2 }
ontUpgradeParams OBJECT-TYPE
SYNTAX INTEGER(0..3)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ontUpgradeParams:
0 ont upgrade
1 ont upgrade commit.
2 ont auto-reboot
3 ont manual-reboot"
::= { ontUpgradeEntry 3 }
ontUpgradeRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus"
::= { ontUpgradeEntry 4 }
-- 1.4.3. ontPortTable ----------------------------------
ontPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont port table, port config."
::= { configOnt 3 }
ontPortEntry OBJECT-TYPE
SYNTAX OntPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont port config table"
INDEX { ontPortSlotIndex, ontPortPportIndex, ontPortOntOnlineIndex, ontPortOntPortIndex }
::= { ontPortTable 1 }
OntPortEntry ::=
SEQUENCE
{
ontPortSlotIndex INTEGER,
ontPortPportIndex INTEGER,
ontPortOntOnlineIndex INTEGER,
ontPortOntPortIndex INTEGER,
ontPortShutdown INTEGER
}
ontPortSlotIndex OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontPortEntry 1 }
ontPortPportIndex OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontPortEntry 2 }
ontPortOntOnlineIndex OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ont online index, the 3rd index of this table. range is <1-128>"
::= { ontPortEntry 3 }
ontPortOntPortIndex OBJECT-TYPE
SYNTAX INTEGER(1..24)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ont port index, the 4th index of this table, range is <1-24>"
::= { ontPortEntry 4 }
ontPortShutdown OBJECT-TYPE
SYNTAX INTEGER { enable(0), disable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ontPortShutdown:
0 enable(default)
1 disable"
::= { ontPortEntry 5 }
--------------------------------------------------------------
------------------ 2.1. status device ----------------------
--------------------------------------------------------------
-- 2.1.1. deployStatus
-- 2.1.2. deployHistoryTable
-- 2.1.3. statusDeviceBaseInfo
-- 2.1.1. deployStatus ------------------------------------
deployStatus OBJECT IDENTIFIER ::= { statusDevice 1 }
deployStatusUserName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"user name of deploy permission owner."
::= { deployStatus 1 }
deployStatusTerminal OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"terminal of deploy permission owner."
::= { deployStatus 2 }
deployStatusUserIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ip address of deploy permission owner."
::= { deployStatus 3 }
deployStatusRequestTime OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"request time of deploy permission owner."
::= { deployStatus 4 }
deployStatusLastActiveTime OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"last active time of deploy permission owner."
::= { deployStatus 5 }
-- 2.1.2. deployHistoryTable ------------------------------
deployHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF DeployHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"deploy history table"
::= { statusDevice 2 }
deployHistoryEntry OBJECT-TYPE
SYNTAX DeployHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of deploy history table"
INDEX { deployHistoryIndex }
::= { deployHistoryTable 1 }
DeployHistoryEntry ::=
SEQUENCE
{
deployHistoryIndex INTEGER,
deployHistoryUserName OCTET STRING,
deployHistoryTerminal OCTET STRING,
deployHistoryUserIp IpAddress,
deployHistoryRequestTime OCTET STRING,
deployHistoryActiveTimeList OCTET STRING,
deployHistoryReleaseTime OCTET STRING
}
deployHistoryIndex OBJECT-TYPE
SYNTAX INTEGER(0..19)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"index of deploy history table."
::= { deployHistoryEntry 1 }
deployHistoryUserName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"user name of deploy history entry."
::= { deployHistoryEntry 2 }
deployHistoryTerminal OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"terminal of deploy history entry."
::= { deployHistoryEntry 3 }
deployHistoryUserIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ip address of deploy history entry."
::= { deployHistoryEntry 4 }
deployHistoryRequestTime OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"request time of deploy history entry. format: yyyy-mm-dd hh:mm:ss"
::= { deployHistoryEntry 5 }
deployHistoryActiveTimeList OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"active time list of deploy history entry. format: yyyy-mm-dd hh:mm:ss,...,.."
::= { deployHistoryEntry 6 }
deployHistoryReleaseTime OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"release time of deploy history entry. format: yyyy-mm-dd hh:mm:ss"
::= { deployHistoryEntry 7 }
-- 2.1.3. statusDeviceBaseInfo ----------------------------
statusDeviceBaseInfo OBJECT IDENTIFIER ::= { statusDevice 3 }
cpuUsePercent OBJECT-TYPE
SYNTAX INTEGER(0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The percentage of use CPU in current system."
::= { statusDeviceBaseInfo 1 }
memUsePercent OBJECT-TYPE
SYNTAX INTEGER(0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The percentage of use memory in current system."
::= { statusDeviceBaseInfo 2 }
switchChipTemperature OBJECT-TYPE
SYNTAX INTEGER(0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature of switch chip in current system."
::= { statusDeviceBaseInfo 3 }
ponChipTemperature OBJECT-TYPE
SYNTAX INTEGER(0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature of pon chip in current system."
::= { statusDeviceBaseInfo 4 }
ontImageName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont image name "
::= { statusDeviceBaseInfo 5 }
ontImageLen OBJECT-TYPE
SYNTAX INTEGER (0..26214400)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont image length "
::= { statusDeviceBaseInfo 6 }
--------------------------------------------------------------
------------------ 2.2. status slot ------------------------
--------------------------------------------------------------
-- 2.2.1. statusSlotPrimaryTable
-- slot status primary table ------------------------------
statusSlotPrimaryTable OBJECT-TYPE
SYNTAX SEQUENCE OF StatusSlotPrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"slot status primary table"
::= { statusSlot 1 }
statusSlotPrimaryEntry OBJECT-TYPE
SYNTAX StatusSlotPrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of slot status primary table"
INDEX { ssSlotIndex }
::= { statusSlotPrimaryTable 1 }
StatusSlotPrimaryEntry ::=
SEQUENCE
{
ssSlotIndex INTEGER,
slotState INTEGER,
slotConfigType INTEGER,
slotTrueType INTEGER,
slotTypeIsPon INTEGER,
slotConnected INTEGER,
slotMac MacAddress,
slotSwVersion OCTET STRING,
slotHwVersion OCTET STRING
}
ssSlotIndex OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"slot index rang is 0 to 5"
::= { statusSlotPrimaryEntry 1 }
slotState OBJECT-TYPE
SYNTAX INTEGER(0..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"typedef enum
{
STATUS_DOWN = 0,
STATUS_INIT,
STATUS_LOAD,
STATUS_REG,
STATUS_CONFIG,
STATUS_ONLINE
}SLOT_STATUS_ENUM;"
::= { statusSlotPrimaryEntry 2 }
slotConfigType OBJECT-TYPE
SYNTAX INTEGER(0..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"typedef enum tag_BOARD_TYPE
{
BOARD_TYPE_NULL = 0,
BOARD_TYPE_CONTROL_BCM5670,
BOARD_TYPE_LINE_24_GE_FIBER_BCM56504,
BOARD_TYPE_LINE_24_GE_COPPER_BCM56504,
BOARD_TYPE_LINE_24_GE_COPPER_BCM56524,
BOARD_TYPE_LINE_8_10GE_FIBER_BCM56820,
BOARD_TYPE_LINE_8PON_6GE_BCM56524,
BOARD_TYPE_CONTROL_BCM56720,
BOARD_TYPE_LINE_8GPON_8GE_BCM56684,
BOARD_TYPE_LINE_4pon_4_10GE_BCM56821,
BOARD_TYPE_NUM
}BOARD_TYPE;
"
::= { statusSlotPrimaryEntry 3 }
slotTrueType OBJECT-TYPE
SYNTAX INTEGER(0..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"typedef enum tag_BOARD_TYPE
{
BOARD_TYPE_NULL = 0,
BOARD_TYPE_CONTROL_BCM5670,
BOARD_TYPE_LINE_24_GE_FIBER_BCM56504,
BOARD_TYPE_LINE_24_GE_COPPER_BCM56504,
BOARD_TYPE_LINE_24_GE_COPPER_BCM56524,
BOARD_TYPE_LINE_8_10GE_FIBER_BCM56820,
BOARD_TYPE_LINE_8PON_6GE_BCM56524,
BOARD_TYPE_CONTROL_BCM56720,
BOARD_TYPE_LINE_8GPON_8GE_BCM56684,
BOARD_TYPE_LINE_4pon_4_10GE_BCM56821,
BOARD_TYPE_NUM
}BOARD_TYPE;"
::= { statusSlotPrimaryEntry 4 }
slotTypeIsPon OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"slotTypeIsPon:
1 true
0 false"
::= { statusSlotPrimaryEntry 5 }
slotConnected OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"slotConnected:
1 true
0 false"
::= { statusSlotPrimaryEntry 6 }
slotMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"slot mac address"
::= { statusSlotPrimaryEntry 7 }
slotSwVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"slotSwVersion"
::= { statusSlotPrimaryEntry 8 }
slotHwVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"slotHwVersion"
::= { statusSlotPrimaryEntry 9 }
--------------------------------------------------------------
------------------ 2.3. status pport ----------------------
--------------------------------------------------------------
-- 2.3.1. ontFindListTable
-- 2.3.2. ontSilentListTable
-- 2.3.3. pportSfpTable
-- 2.3.4. statusPportPrimaryTable
-- 2.3.5. portUtilizationTable
-- ont find list table ------------------------------------
ontFindListTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntFindListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont find list table"
::= { statusPport 1 }
ontFindListEntry OBJECT-TYPE
SYNTAX OntFindListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont find list table"
INDEX { spSlotIndex, spPportIndex, ontFindListListId }
::= { ontFindListTable 1 }
OntFindListEntry ::=
SEQUENCE
{
spSlotIndex INTEGER,
spPportIndex INTEGER,
ontFindListListId INTEGER,
ontFindListSn OCTET STRING,
ontFindListPw OCTET STRING,
ontFindListLoid OCTET STRING,
ontFindListLopw OCTET STRING,
ontFindListVendorId OCTET STRING,
ontFindListPriSwVer OCTET STRING,
ontFindListSecSwVer OCTET STRING,
ontFindListHwVer OCTET STRING,
ontFindListEquipId OCTET STRING,
ontFindListFirstFindTime OCTET STRING,
ontFindListLastFindTime OCTET STRING,
ontFindListFindCnt OCTET STRING
}
spSlotIndex OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontFindListEntry 1 }
spPportIndex OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontFindListEntry 2 }
ontFindListListId OBJECT-TYPE
SYNTAX INTEGER(0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont find list table."
::= { ontFindListEntry 3 }
ontFindListSn OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"serial number of ont find list entry."
::= { ontFindListEntry 4 }
ontFindListPw OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"password of ont find list entry."
::= { ontFindListEntry 5 }
ontFindListLoid OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"logic id of ont find list entry."
::= { ontFindListEntry 6 }
ontFindListLopw OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"logic password of ont find list entry."
::= { ontFindListEntry 7 }
ontFindListVendorId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"vendor id of ont find list entry."
::= { ontFindListEntry 8 }
ontFindListPriSwVer OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"primary software version of ont find list entry."
::= { ontFindListEntry 9 }
ontFindListSecSwVer OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"secondary software version of ont find list entry."
::= { ontFindListEntry 10 }
ontFindListHwVer OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"hardware version of ont find list entry."
::= { ontFindListEntry 11 }
ontFindListEquipId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"equipment id of ont find list entry."
::= { ontFindListEntry 12 }
ontFindListFirstFindTime OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"first find time of ont find list entry."
::= { ontFindListEntry 13 }
ontFindListLastFindTime OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"last find time of ont find list entry."
::= { ontFindListEntry 14 }
ontFindListFindCnt OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"find count of ont find list entry."
::= { ontFindListEntry 15 }
-- ont silent list table ----------------------------------
ontSilentListTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntSilentListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont silent list table"
::= { statusPport 2 }
ontSilentListEntry OBJECT-TYPE
SYNTAX OntSilentListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont find list table"
INDEX { spSlotIndexI, spPportIndexI, ontSilentListListId }
::= { ontSilentListTable 1 }
OntSilentListEntry ::=
SEQUENCE
{
spSlotIndexI INTEGER,
spPportIndexI INTEGER,
ontSilentListListId INTEGER,
ontSilentListSn OCTET STRING,
ontSilentListTime INTEGER,
ontSilentListReason OCTET STRING
}
spSlotIndexI OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontSilentListEntry 1 }
spPportIndexI OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontSilentListEntry 2 }
ontSilentListListId OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont silent list table."
::= { ontSilentListEntry 3 }
ontSilentListSn OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"serial number of ont silent list entry."
::= { ontSilentListEntry 4 }
ontSilentListTime OBJECT-TYPE
SYNTAX INTEGER(1..86400)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"remain time of ont silent list entry, unit is second."
::= { ontSilentListEntry 5 }
ontSilentListReason OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"silent reason of ont silent list entry."
::= { ontSilentListEntry 6 }
-- 2.3.1. pportSfpTable ------------------------------
pportSfpTable OBJECT-TYPE
SYNTAX SEQUENCE OF PportSfpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"pport sfp info table"
::= { statusPport 3 }
pportSfpEntry OBJECT-TYPE
SYNTAX PportSfpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of pport sfp info table"
INDEX { spSlotIndexII, spPportIndexII }
::= { pportSfpTable 1 }
PportSfpEntry ::=
SEQUENCE
{
spSlotIndexII INTEGER,
spPportIndexII INTEGER,
sfpTransceiverType OCTET STRING,
sfpCompliance OCTET STRING,
sfpConnectorType OCTET STRING,
sfpWaveLength OCTET STRING,
sfpTransferDistance OCTET STRING,
sfpDigitalDiagMonitor OCTET STRING,
sfpManuSerialNumber OCTET STRING,
sfpManufacturingDate OCTET STRING,
sfpVendorName OCTET STRING,
sfpTemperature OCTET STRING,
sfpVoltage OCTET STRING,
sfpBiasCurrent OCTET STRING,
sfpBiasHighThreshold OCTET STRING,
sfpBiasLowThreshold OCTET STRING,
sfpRXPower OCTET STRING,
sfpRXPowerHighThreshold OCTET STRING,
sfpRXPowerLowThreshold OCTET STRING,
sfpTXPower OCTET STRING,
sfpTXPowerHighThreshold OCTET STRING,
sfpTXPowerLowThreshold OCTET STRING,
sfpExist INTEGER,
sfpLinkState INTEGER,
sfpModuleType INTEGER,
sfpModuleSubType INTEGER,
sfpUsedType INTEGER,
sfpPartNumber OCTET STRING
}
spSlotIndexII OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { pportSfpEntry 1 }
spPportIndexII OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { pportSfpEntry 2 }
sfpTransceiverType OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp transceiver type."
::= { pportSfpEntry 3 }
sfpCompliance OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp compliance."
::= { pportSfpEntry 4 }
sfpConnectorType OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp connector type."
::= { pportSfpEntry 5 }
sfpWaveLength OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp wave length."
::= { pportSfpEntry 6 }
sfpTransferDistance OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp transfer distance."
::= { pportSfpEntry 7 }
sfpDigitalDiagMonitor OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp digital diagnostic monitoring."
::= { pportSfpEntry 8 }
sfpManuSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp manufacturing serial number."
::= { pportSfpEntry 9 }
sfpManufacturingDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp manufacturing date."
::= { pportSfpEntry 10 }
sfpVendorName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp vendor name."
::= { pportSfpEntry 11 }
sfpTemperature OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp temperature(<28><>C)."
::= { pportSfpEntry 12 }
sfpVoltage OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp voltage(V)."
::= { pportSfpEntry 13 }
sfpBiasCurrent OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp bias current(mA)."
::= { pportSfpEntry 14 }
sfpBiasHighThreshold OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp bias high threshold(mA)."
::= { pportSfpEntry 15 }
sfpBiasLowThreshold OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp bias low threshold(mA)."
::= { pportSfpEntry 16 }
sfpRXPower OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp rx power(dBm)."
::= { pportSfpEntry 17 }
sfpRXPowerHighThreshold OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp rx power high threshold(dBm)."
::= { pportSfpEntry 18 }
sfpRXPowerLowThreshold OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp rx power low threshold(dBm)."
::= { pportSfpEntry 19 }
sfpTXPower OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp tx power(dBm)."
::= { pportSfpEntry 20 }
sfpTXPowerHighThreshold OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp tx power high threshold(dBm)."
::= { pportSfpEntry 21 }
sfpTXPowerLowThreshold OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp tx power low threshold(dBm)."
::= { pportSfpEntry 22 }
sfpExist OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfpExist:
0 false
1 true"
::= { pportSfpEntry 23 }
sfpLinkState OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfpLinkState:
0 link down
1 link up"
::= { pportSfpEntry 24 }
sfpModuleType OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfpModuleType:
0 unknown
1 GPON"
::= { pportSfpEntry 25 }
sfpModuleSubType OBJECT-TYPE
SYNTAX INTEGER(0..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfpModuleSubType:
0 unknown
1 Class B+
2 Class C+"
::= { pportSfpEntry 26 }
sfpUsedType OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sfpModuleSubType:
0 unknown
1 ONT"
::= { pportSfpEntry 27 }
sfpPartNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sfp manufacturing type."
::= { pportSfpEntry 28 }
-- status pport primary table
statusPportPrimaryTable OBJECT-TYPE
SYNTAX SEQUENCE OF StatusPportPrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"status pport primary table"
::= { statusPport 4 }
statusPportPrimaryEntry OBJECT-TYPE
SYNTAX StatusPportPrimaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont find list table"
INDEX { spSlotIndexIII, spPportIndexIII }
::= { statusPportPrimaryTable 1 }
StatusPportPrimaryEntry ::=
SEQUENCE
{
spSlotIndexIII INTEGER,
spPportIndexIII INTEGER,
pportLinkStatus INTEGER
}
spSlotIndexIII OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { statusPportPrimaryEntry 1 }
spPportIndexIII OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { statusPportPrimaryEntry 2 }
pportLinkStatus OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"pportLinkStatus:
0 link down
1 link up"
::= { statusPportPrimaryEntry 3 }
-- port utilization table ------------------------------------
portUtilizationTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortUtilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"port utilization table"
::= { statusPport 5 }
portUtilizationEntry OBJECT-TYPE
SYNTAX PortUtilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of port utilization table"
INDEX { spSlotIndexPort, spPortIndex }
::= { portUtilizationTable 1 }
PortUtilizationEntry ::=
SEQUENCE
{
spSlotIndexPort INTEGER,
spPortIndex INTEGER,
spUtilizeTxOctetsRate INTEGER,
spUtilizeRxOctetsRate INTEGER,
spUtilizeTxBwThoughput INTEGER,
spUtilizeRxBwThoughput INTEGER,
spUtilizeTxPktsRate INTEGER,
spUtilizeRxPktsRate INTEGER,
spUtilizeTxOctetsMaxRate INTEGER,
spUtilizeRxOctetsMaxRate INTEGER
}
spSlotIndexPort OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { portUtilizationEntry 1 }
spPortIndex OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of port, should in <1-16>."
::= { portUtilizationEntry 2 }
spUtilizeTxOctetsRate OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port tx octets rate."
::= { portUtilizationEntry 3 }
spUtilizeRxOctetsRate OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port rx octets rate."
::= { portUtilizationEntry 4 }
spUtilizeTxBwThoughput OBJECT-TYPE
SYNTAX INTEGER(0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port tx bandwidth thoughput."
::= { portUtilizationEntry 5 }
spUtilizeRxBwThoughput OBJECT-TYPE
SYNTAX INTEGER(0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port rx bandwidth thoughput."
::= { portUtilizationEntry 6 }
spUtilizeTxPktsRate OBJECT-TYPE
SYNTAX INTEGER(0..1600000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port tx packets rate."
::= { portUtilizationEntry 7 }
spUtilizeRxPktsRate OBJECT-TYPE
SYNTAX INTEGER(0..1600000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port rx packets rate."
::= { portUtilizationEntry 8 }
spUtilizeTxOctetsMaxRate OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port tx octets max rate."
::= { portUtilizationEntry 9 }
spUtilizeRxOctetsMaxRate OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port rx octets max rate."
::= { portUtilizationEntry 10 }
--------------------------------------------------------------
------------------ 2.4. status ont ------------------------
--------------------------------------------------------------
-- 2.4.1 ontInfo
-- 2.4.2 ontEthPortInfo
-- 2.4.3 ontGemPortInfo
-- 2.4.4 ontWanInfo
-- 2.4.5 ontPotsInfo
-- ont infomation ------------------------------------------
ontInfo OBJECT IDENTIFIER ::= { statusOnt 1 }
-- 2.4.1.1 ontBaseInfoTable
-- 2.4.1.2 ontVersionInfoTable
-- 2.4.1.3 ontCapabilityTable
-- 2.4.1.4 ontOpticalInfoTable
-- 2.4.1.5 ontProfileInfoTable
-- 2.4.1.6 ontUpgradeStatusTable
-- 2.4.1.7 ontStatisticsTable
-- 2.4.1.8 ontUtilizationTable
-- 2.4.1.9 ontOpticalSwTable
-- 2.4.1.10 ontMacAddrTable
-- ont base status table ----------------------------------
ontBaseInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntBaseInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont base infomation table"
::= { ontInfo 1 }
ontBaseInfoEntry OBJECT-TYPE
SYNTAX OntBaseInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont base infomation table"
INDEX { soSlotIndex, soPportIndex, soOntIndex }
::= { ontBaseInfoTable 1 }
OntBaseInfoEntry ::=
SEQUENCE
{
soSlotIndex INTEGER,
soPportIndex INTEGER,
soOntIndex INTEGER,
ontDescription OCTET STRING,
ontDeviceType OCTET STRING,
ontRunStatus INTEGER,
ontDistance OCTET STRING,
ontSn OCTET STRING,
ontPw OCTET STRING,
ontLoid OCTET STRING,
ontLopw OCTET STRING,
ontOfflineReason OCTET STRING,
ontOnOfflineTime OCTET STRING,
ontUpDownTime OCTET STRING
}
soSlotIndex OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontBaseInfoEntry 1 }
soPportIndex OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontBaseInfoEntry 2 }
soOntIndex OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont, the 3rd index of this table.
Should in <1-128>."
::= { ontBaseInfoEntry 3 }
ontDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont description."
::= { ontBaseInfoEntry 4 }
ontDeviceType OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont device type."
::= { ontBaseInfoEntry 5 }
ontRunStatus OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ontRunStatus:
0 offline
1 online"
::= { ontBaseInfoEntry 6 }
ontDistance OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont distance."
::= { ontBaseInfoEntry 7 }
ontSn OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont serial number, hex string format."
::= { ontBaseInfoEntry 8 }
ontPw OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont password, hex string format."
::= { ontBaseInfoEntry 9 }
ontLoid OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"logical ont id, Charactor format."
::= { ontBaseInfoEntry 10 }
ontLopw OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"logical ont password, Charactor format."
::= { ontBaseInfoEntry 11 }
ontOfflineReason OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont off line reason.
0: NONE Reason get fail ԭ<><D4AD><EFBFBD><EFBFBD>ȡʧ<C8A1><CAA7>
1: DEACTIVATION ONT DEACTIVED ONTȥ<54><C8A5><EFBFBD><EFBFBD>
2: ACK_TIMEOUT ONT acknowledge time out ONTȷ<54><C8B7><EFBFBD><EFBFBD>Ӧ<EFBFBD><D3A6>ʱ
3: SFI Signal fail of ONT ONT<4E>ź<EFBFBD>ʧЧ
4: TIWI Transmission interface warning ONT<4E><54><EFBFBD><EFBFBD><EFBFBD>˿ھ<CBBF>ʾ
5: PASSWORD_AUTHENTICATION ONT password authentication fail ONT<4E><54><EFBFBD><EFBFBD><EFBFBD><EFBFBD>֤ʧ<D6A4><CAA7>
6: LOSI Loss of signal for ONT ONT<4E><54><EFBFBD><EFBFBD><EFBFBD>źŶ<C5BA>ʧ
7: LOS Loss of signal for OLT OLT<4C><54><EFBFBD><EFBFBD><EFBFBD>źŶ<C5BA>ʧ
8: LOKI Loss of key synch with ONT ONTͬ<54><CDAC><EFBFBD><EFBFBD>Կ<EFBFBD><D4BF>ʧ
9: RERANGE_FAILURE ONT re-ranging fail ONT<4E>ز<EFBFBD><D8B2><EFBFBD>ʧ<EFBFBD><CAA7>
10: LOFI Loss of frame of ONT ONT<4E><54><EFBFBD><EFBFBD>֡<EFBFBD><D6A1>ʧ
11: POWER_OFF ONT power off ONT<4E><54><EFBFBD><EFBFBD>
12: UNKNOWN UNKNOWN δ֪
13: LOAMI Loss of PLOAM for ONT ONT<4E><54><EFBFBD><EFBFBD>PLOAM<41><4D>ʧ
"
::= { ontBaseInfoEntry 12 }
ontOnOfflineTime OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont on/off line time."
::= { ontBaseInfoEntry 13 }
ontUpDownTime OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont up/down time."
::= { ontBaseInfoEntry 14 }
-- ont version info table ----------------------------------
ontVersionInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntVersionInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont version info table"
::= { ontInfo 2 }
ontVersionInfoEntry OBJECT-TYPE
SYNTAX OntVersionInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont version info table"
INDEX { soSlotIndexI, soPportIndexI, soOntIndexI }
::= { ontVersionInfoTable 1 }
OntVersionInfoEntry ::=
SEQUENCE
{
soSlotIndexI INTEGER,
soPportIndexI INTEGER,
soOntIndexI INTEGER,
ontVendorId OCTET STRING,
ontVersion OCTET STRING,
ontEquipmentId OCTET STRING,
ontMainSwVersion OCTET STRING,
ontSecondSwVersion OCTET STRING
}
soSlotIndexI OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontVersionInfoEntry 1 }
soPportIndexI OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontVersionInfoEntry 2 }
soOntIndexI OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont, the 3rd index of this table.
Should in <1-128>."
::= { ontVersionInfoEntry 3 }
ontVendorId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont vendor id."
::= { ontVersionInfoEntry 4 }
ontVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont version."
::= { ontVersionInfoEntry 5 }
ontEquipmentId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont equipment id."
::= { ontVersionInfoEntry 6 }
ontMainSwVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont primary software version."
::= { ontVersionInfoEntry 7 }
ontSecondSwVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont secondary software version."
::= { ontVersionInfoEntry 8 }
-- ont capability info table ------------------------------
ontCapabilityTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntCapabilityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont capability info table."
::= { ontInfo 3 }
ontCapabilityEntry OBJECT-TYPE
SYNTAX OntCapabilityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont capability info table"
INDEX { soSlotIndexII, soPportIndexII, soOntIndexII }
::= { ontCapabilityTable 1 }
OntCapabilityEntry ::=
SEQUENCE
{
soSlotIndexII INTEGER,
soPportIndexII INTEGER,
soOntIndexII INTEGER,
ontCapEquipId OCTET STRING,
ontUplinkPonPortsNum INTEGER,
ontPotsPortsNum INTEGER,
ontEthPortsNum INTEGER,
ontTdmPortsNum INTEGER,
ontMocaPortsNum INTEGER,
ontCatvAniPortsNum INTEGER,
ontCatvUniPortsNum INTEGER,
ontTcontsNum INTEGER,
ontGemPortsNum INTEGER,
ontTrafficSchedulersNum INTEGER,
ontPqsInTconts OCTET STRING,
ontIpConfigSupport OCTET STRING,
ontFlowCtrlType OCTET STRING,
ontTXpowerCutOffSupport OCTET STRING,
ontDbaMethod OCTET STRING
}
soSlotIndexII OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontCapabilityEntry 1 }
soPportIndexII OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontCapabilityEntry 2 }
soOntIndexII OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont, the 3rd index of this table.
Should in <1-128>."
::= { ontCapabilityEntry 3 }
ontCapEquipId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont equipment id."
::= { ontCapabilityEntry 4 }
ontUplinkPonPortsNum OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of uplink PON ports."
::= { ontCapabilityEntry 5 }
ontPotsPortsNum OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of POTS ports."
::= { ontCapabilityEntry 6 }
ontEthPortsNum OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of ETH ports."
::= { ontCapabilityEntry 7 }
ontTdmPortsNum OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of TDM ports."
::= { ontCapabilityEntry 8 }
ontMocaPortsNum OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of MOCA ports."
::= { ontCapabilityEntry 9 }
ontCatvAniPortsNum OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of CATV ANI ports."
::= { ontCapabilityEntry 10 }
ontCatvUniPortsNum OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of CATV UNI ports."
::= { ontCapabilityEntry 11 }
ontTcontsNum OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of T-CONTs."
::= { ontCapabilityEntry 12 }
ontGemPortsNum OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of GEM ports."
::= { ontCapabilityEntry 13 }
ontTrafficSchedulersNum OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number of traffic schedulers."
::= { ontCapabilityEntry 14 }
ontPqsInTconts OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont support ip configuration or not."
::= { ontCapabilityEntry 15 }
ontIpConfigSupport OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont support ip configuration or not."
::= { ontCapabilityEntry 16 }
ontFlowCtrlType OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont flow control type."
::= { ontCapabilityEntry 17 }
ontTXpowerCutOffSupport OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont support TX power cut off or not."
::= { ontCapabilityEntry 18 }
ontDbaMethod OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont dba method.
NSR(default): not support SR
SR: support SR
-: invalid"
::= { ontCapabilityEntry 19 }
-- ont optical info table ----------------------------------
ontOpticalInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntOpticalInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont optical info table"
::= { ontInfo 4 }
ontOpticalInfoEntry OBJECT-TYPE
SYNTAX OntOpticalInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont optical info table"
INDEX { soSlotIndexIII, soPportIndexIII, soOntIndexIII }
::= { ontOpticalInfoTable 1 }
OntOpticalInfoEntry ::=
SEQUENCE
{
soSlotIndexIII INTEGER,
soPportIndexIII INTEGER,
soOntIndexIII INTEGER,
ontVoltage OCTET STRING,
ontRXPower OCTET STRING,
ontTXPower OCTET STRING,
ontBiasCurrent OCTET STRING,
ontTemperature OCTET STRING,
ontRxCatvPower OCTET STRING,
ontTxCatvPower OCTET STRING,
ontOltRxPower OCTET STRING,
ontOltTxPower OCTET STRING
}
soSlotIndexIII OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontOpticalInfoEntry 1 }
soPportIndexIII OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontOpticalInfoEntry 2 }
soOntIndexIII OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont, the 3rd index of this table.
Should in <1-128>."
::= { ontOpticalInfoEntry 3 }
ontVoltage OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont power feed voltage(V)."
::= { ontOpticalInfoEntry 4 }
ontRXPower OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont received optical power(dBm)."
::= { ontOpticalInfoEntry 5 }
ontTXPower OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont mean optical launch power(dBm)."
::= { ontOpticalInfoEntry 6 }
ontBiasCurrent OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont laser bias current(uA)."
::= { ontOpticalInfoEntry 7 }
ontTemperature OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont temperature(<28><>C)."
::= { ontOpticalInfoEntry 8 }
ontRxCatvPower OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont received catv power(dBm)."
::= { ontOpticalInfoEntry 9 }
ontTxCatvPower OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont transmitted catv power(dBmV)."
::= { ontOpticalInfoEntry 10 }
ontOltRxPower OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"olt received ont power(dBm)."
::= { ontOpticalInfoEntry 11 }
ontOltTxPower OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"olt transmitted power(dBm)."
::= { ontOpticalInfoEntry 12 }
-- ont profile info table ----------------------------------
ontProfileInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntProfileInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont optical info table"
::= { ontInfo 5 }
ontProfileInfoEntry OBJECT-TYPE
SYNTAX OntProfileInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont profile info table"
INDEX { soSlotIndexIV, soPportIndexIV, soOntIndexIV }
::= { ontProfileInfoTable 1 }
OntProfileInfoEntry ::=
SEQUENCE
{
soSlotIndexIV INTEGER,
soPportIndexIV INTEGER,
soOntIndexIV INTEGER,
ontProfileSn OCTET STRING,
ontProfileVlanIdxes OCTET STRING,
ontProfileVlanNames OCTET STRING,
ontProfileUsIdxes OCTET STRING,
ontProfileUsNames OCTET STRING,
ontProfileDsIdxes OCTET STRING,
ontProfileDsNames OCTET STRING,
ontProfileDbaIdxes OCTET STRING,
ontProfileDbaNames OCTET STRING,
ontProfileLineIdx INTEGER,
ontProfileLineName OCTET STRING,
ontProfileRuleIdx INTEGER,
ontProfileRuleName OCTET STRING,
ontProfileUniqueIdx OCTET STRING,
ontProfileUniqueName OCTET STRING
}
soSlotIndexIV OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontProfileInfoEntry 1 }
soPportIndexIV OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontProfileInfoEntry 2 }
soOntIndexIV OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont, the 3rd index of this table.
Should in <1-128>."
::= { ontProfileInfoEntry 3 }
ontProfileSn OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont sn"
::= { ontProfileInfoEntry 4 }
ontProfileVlanIdxes OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"vlan indexes ont used, such as '100,200,233'. if no vlan used, '-'."
::= { ontProfileInfoEntry 5 }
ontProfileVlanNames OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"vlan names ont used, such as 'INDEX_100,INDEX_200,INDEX_233'. if no vlan used, '-'.
Name list may too long to show. Suggest use ontProfileVlanIdxes above."
-- ÿ<><C3BF> name <20><><EFBFBD><EFBFBD><EFBFBD>󳤶<EFBFBD><F3B3A4B6><EFBFBD> 127<32><37><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ĺܳ<C4BA><DCB3><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ʹ<EFBFBD><CAB9><EFBFBD>˶<EFBFBD><CBB6><EFBFBD><EFBFBD><EFBFBD>Ŀ<EFBFBD><C4BF><EFBFBD><EFBFBD><EFBFBD>п<EFBFBD><D0BF>ܳ<EFBFBD><DCB3><EFBFBD> 255 <20><>
-- <20>ֽڡ<D6BD><DAA1><EFBFBD>ʱ<EFBFBD><CAB1><EFBFBD><EFBFBD>ֵ<EFBFBD><D6B5><EFBFBD><EFBFBD>ȡ<EFBFBD><C8A1><EFBFBD><EFBFBD><EFBFBD><EFBFBD> 255 <20>ֽڣ<D6BD><DAA3><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ص<EFBFBD><D8B5><EFBFBD><EFBFBD><EFBFBD>һ<EFBFBD><D2BB><EFBFBD><EFBFBD><EFBFBD><EFBFBD>','<27><><EFBFBD>Ա<EFBFBD>ʾ<EFBFBD><CABE><EFBFBD><EFBFBD>û<EFBFBD><C3BB><EFBFBD>صģ<D8B5>
::= { ontProfileInfoEntry 6 }
ontProfileUsIdxes OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"us traffic indexes ont used, such as '100,200,233'. if no us traffic used, '-'."
::= { ontProfileInfoEntry 7 }
ontProfileUsNames OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"us traffic names ont used, such as 'INDEX_100,INDEX_200,INDEX_233'. if no us used, '-'.
Name list may too long to show. Suggest use ontProfileVlanIdxes above."
-- ÿ<><C3BF> name <20><><EFBFBD><EFBFBD><EFBFBD>󳤶<EFBFBD><F3B3A4B6><EFBFBD> 127<32><37><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ĺܳ<C4BA><DCB3><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ʹ<EFBFBD><CAB9><EFBFBD>˶<EFBFBD><CBB6><EFBFBD><EFBFBD><EFBFBD>Ŀ<EFBFBD><C4BF><EFBFBD><EFBFBD><EFBFBD>п<EFBFBD><D0BF>ܳ<EFBFBD><DCB3><EFBFBD> 255 <20><>
-- <20>ֽڡ<D6BD><DAA1><EFBFBD>ʱ<EFBFBD><CAB1><EFBFBD><EFBFBD>ֵ<EFBFBD><D6B5><EFBFBD><EFBFBD>ȡ<EFBFBD><C8A1><EFBFBD><EFBFBD><EFBFBD><EFBFBD> 255 <20>ֽڣ<D6BD><DAA3><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ص<EFBFBD><D8B5><EFBFBD><EFBFBD><EFBFBD>һ<EFBFBD><D2BB><EFBFBD><EFBFBD><EFBFBD><EFBFBD>','<27><><EFBFBD>Ա<EFBFBD>ʾ<EFBFBD><CABE><EFBFBD><EFBFBD>û<EFBFBD><C3BB><EFBFBD>صģ<D8B5>
::= { ontProfileInfoEntry 8 }
ontProfileDsIdxes OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ds traffic indexes ont used, such as '100,200,233'. if no ds traffic used, '-'."
::= { ontProfileInfoEntry 9 }
ontProfileDsNames OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ds traffic names ont used, such as 'INDEX_100,INDEX_200,INDEX_233'. if no ds used, '-'.
Name list may too long to show. Suggest use ontProfileVlanIdxes above."
-- ÿ<><C3BF> name <20><><EFBFBD><EFBFBD><EFBFBD>󳤶<EFBFBD><F3B3A4B6><EFBFBD> 127<32><37><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ĺܳ<C4BA><DCB3><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ʹ<EFBFBD><CAB9><EFBFBD>˶<EFBFBD><CBB6><EFBFBD><EFBFBD><EFBFBD>Ŀ<EFBFBD><C4BF><EFBFBD><EFBFBD><EFBFBD>п<EFBFBD><D0BF>ܳ<EFBFBD><DCB3><EFBFBD> 255 <20><>
-- <20>ֽڡ<D6BD><DAA1><EFBFBD>ʱ<EFBFBD><CAB1><EFBFBD><EFBFBD>ֵ<EFBFBD><D6B5><EFBFBD><EFBFBD>ȡ<EFBFBD><C8A1><EFBFBD><EFBFBD><EFBFBD><EFBFBD> 255 <20>ֽڣ<D6BD><DAA3><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ص<EFBFBD><D8B5><EFBFBD><EFBFBD><EFBFBD>һ<EFBFBD><D2BB><EFBFBD><EFBFBD><EFBFBD><EFBFBD>','<27><><EFBFBD>Ա<EFBFBD>ʾ<EFBFBD><CABE><EFBFBD><EFBFBD>û<EFBFBD><C3BB><EFBFBD>صģ<D8B5>
::= { ontProfileInfoEntry 10 }
ontProfileDbaIdxes OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"dba indexes ont used, such as '100,200,233'. if no dba used, '-'."
::= { ontProfileInfoEntry 11 }
ontProfileDbaNames OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"dba names ont used, such as 'INDEX_100,INDEX_200,INDEX_233'. if no dba used, '-'.
Name list may too long to show. Suggest use ontProfileVlanIdxes above."
-- ÿ<><C3BF> name <20><><EFBFBD><EFBFBD><EFBFBD>󳤶<EFBFBD><F3B3A4B6><EFBFBD> 127<32><37><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ĺܳ<C4BA><DCB3><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ʹ<EFBFBD><CAB9><EFBFBD>˶<EFBFBD><CBB6><EFBFBD><EFBFBD><EFBFBD>Ŀ<EFBFBD><C4BF><EFBFBD><EFBFBD><EFBFBD>п<EFBFBD><D0BF>ܳ<EFBFBD><DCB3><EFBFBD> 255 <20><>
-- <20>ֽڡ<D6BD><DAA1><EFBFBD>ʱ<EFBFBD><CAB1><EFBFBD><EFBFBD>ֵ<EFBFBD><D6B5><EFBFBD><EFBFBD>ȡ<EFBFBD><C8A1><EFBFBD><EFBFBD><EFBFBD><EFBFBD> 255 <20>ֽڣ<D6BD><DAA3><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ص<EFBFBD><D8B5><EFBFBD><EFBFBD><EFBFBD>һ<EFBFBD><D2BB><EFBFBD><EFBFBD><EFBFBD><EFBFBD>','<27><><EFBFBD>Ա<EFBFBD>ʾ<EFBFBD><CABE><EFBFBD><EFBFBD>û<EFBFBD><C3BB><EFBFBD>صģ<D8B5>
::= { ontProfileInfoEntry 12 }
ontProfileLineIdx OBJECT-TYPE
SYNTAX INTEGER(1..4096)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"line id ont used."
::= { ontProfileInfoEntry 13 }
ontProfileLineName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"line name ont used."
::= { ontProfileInfoEntry 14 }
ontProfileRuleIdx OBJECT-TYPE
SYNTAX INTEGER(1..4096)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"rule id ont used."
::= { ontProfileInfoEntry 15 }
ontProfileRuleName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"rule name ont used."
::= { ontProfileInfoEntry 16 }
ontProfileUniqueIdx OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"unique id ont used. if no unique used, '-'"
::= { ontProfileInfoEntry 17 }
ontProfileUniqueName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"unique name ont used. if no unique used, '-'"
::= { ontProfileInfoEntry 18 }
-- ont upgrade status table --------------------------------
ontUpgradeStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntUpgradeStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont upgrade status table"
::= { ontInfo 6 }
ontUpgradeStatusEntry OBJECT-TYPE
SYNTAX OntUpgradeStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont upgrade status table"
INDEX { soSlotIndexV, soPportIndexV, soOntIndexV }
::= { ontUpgradeStatusTable 1 }
OntUpgradeStatusEntry ::=
SEQUENCE
{
soSlotIndexV INTEGER,
soPportIndexV INTEGER,
soOntIndexV INTEGER,
ontUpgradeActiveVer OCTET STRING,
ontUpgradeInactiveVer OCTET STRING,
ontUpgradeStatus OCTET STRING
}
soSlotIndexV OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontUpgradeStatusEntry 1 }
soPportIndexV OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontUpgradeStatusEntry 2 }
soOntIndexV OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont, the 3rd index of this table.
Should in <1-128>."
::= { ontUpgradeStatusEntry 3 }
ontUpgradeActiveVer OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont upgrade active version."
::= { ontUpgradeStatusEntry 4 }
ontUpgradeInactiveVer OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont upgrade inactive version."
::= { ontUpgradeStatusEntry 5 }
ontUpgradeStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont upgrade status, such as success, crc error, timeout, offline, 0%-100%."
::= { ontUpgradeStatusEntry 6 }
-- ont statistics table ------------------------------------
ontStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont statistics table"
::= { ontInfo 7 }
ontStatisticsEntry OBJECT-TYPE
SYNTAX OntStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont statistics table"
INDEX { soSlotIndexX, soPportIndexX, soOntIndexX }
::= { ontStatisticsTable 1 }
OntStatisticsEntry ::=
SEQUENCE
{
soSlotIndexX INTEGER,
soPportIndexX INTEGER,
soOntIndexX INTEGER,
ontUsFrames OCTET STRING,
ontUsBytes OCTET STRING,
ontDsFrames OCTET STRING,
ontDsBytes OCTET STRING,
ontUsRate OCTET STRING,
ontDsRate OCTET STRING
}
soSlotIndexX OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontStatisticsEntry 1 }
soPportIndexX OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontStatisticsEntry 2 }
soOntIndexX OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont, the 3rd index of this table.
Should in <1-128>."
::= { ontStatisticsEntry 3 }
ontUsFrames OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont upstream frames."
::= { ontStatisticsEntry 4 }
ontUsBytes OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont upstream bytes."
::= { ontStatisticsEntry 5 }
ontDsFrames OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont downstream frames."
::= { ontStatisticsEntry 6 }
ontDsBytes OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont downstream bytes."
::= { ontStatisticsEntry 7 }
ontUsRate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont upstream rate."
::= { ontStatisticsEntry 8 }
ontDsRate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont downstream rate."
::= { ontStatisticsEntry 9 }
-- ont utilization table ------------------------------------
ontUtilizationTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntUtilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont utilization table"
::= { ontInfo 8 }
ontUtilizationEntry OBJECT-TYPE
SYNTAX OntUtilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont utilization table"
INDEX { soSlotIndexXII, soPportIndexXII, soOntIndexXII }
::= { ontUtilizationTable 1 }
OntUtilizationEntry ::=
SEQUENCE
{
soSlotIndexXII INTEGER,
soPportIndexXII INTEGER,
soOntIndexXII INTEGER,
soUtilizeTxOctetsRate INTEGER,
soUtilizeRxOctetsRate INTEGER,
soUtilizeTxPktsRate INTEGER,
soUtilizeRxPktsRate INTEGER,
soUtilizeTxOctets INTEGER,
soUtilizeRxOctets INTEGER,
soUtilizeTxPktsError INTEGER,
soUtilizeRxPktsError INTEGER,
soUtilizeTxPktsDiscard INTEGER,
soUtilizeRxPktsDiscard INTEGER,
soUtilizeTxThroughput INTEGER,
soUtilizeRxThroughput INTEGER
}
soSlotIndexXII OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontUtilizationEntry 1 }
soPportIndexXII OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontUtilizationEntry 2 }
soOntIndexXII OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont, the 3rd index of this table.
Should in <1-128>."
::= { ontUtilizationEntry 3 }
soUtilizeTxOctetsRate OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont tx octets rate."
::= { ontUtilizationEntry 4 }
soUtilizeRxOctetsRate OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont rx octets rate."
::= { ontUtilizationEntry 5 }
soUtilizeTxPktsRate OBJECT-TYPE
SYNTAX INTEGER(0..1600000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont tx packets rate(pps)."
::= { ontUtilizationEntry 6 }
soUtilizeRxPktsRate OBJECT-TYPE
SYNTAX INTEGER(0..1600000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont rx packets rate(pps)."
::= { ontUtilizationEntry 7 }
soUtilizeTxOctets OBJECT-TYPE
SYNTAX INTEGER(0..1600000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont tx octets in 15 minutes."
::= { ontUtilizationEntry 8 }
soUtilizeRxOctets OBJECT-TYPE
SYNTAX INTEGER(0..1600000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont rx octets in 15 minutes."
::= { ontUtilizationEntry 9 }
soUtilizeTxPktsError OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port tx packets error in 15 minute."
::= { ontUtilizationEntry 10 }
soUtilizeRxPktsError OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port rx packets error in 15 minute."
::= { ontUtilizationEntry 11 }
soUtilizeTxPktsDiscard OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port tx packets discard in 15 minute."
::= { ontUtilizationEntry 12 }
soUtilizeRxPktsDiscard OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port rx packets discard in 15 minute."
::= { ontUtilizationEntry 13 }
soUtilizeTxThroughput OBJECT-TYPE
SYNTAX INTEGER(0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port tx throughput."
::= { ontUtilizationEntry 14 }
soUtilizeRxThroughput OBJECT-TYPE
SYNTAX INTEGER(0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port rx throughput."
::= { ontUtilizationEntry 15 }
-- ont optical software table ----------------------------------
ontOpticalSwTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntOpticalSwEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont optical software table"
::= { ontInfo 9 }
ontOpticalSwEntry OBJECT-TYPE
SYNTAX OntOpticalSwEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont optical software table"
INDEX { soSlotIndexXV, soPportIndexXV, soOntIndexXV }
::= { ontOpticalSwTable 1 }
OntOpticalSwEntry ::=
SEQUENCE
{
soSlotIndexXV INTEGER,
soPportIndexXV INTEGER,
soOntIndexXV INTEGER,
ontVoltageI OCTET STRING,
ontRXPowerI OCTET STRING,
ontTXPowerI OCTET STRING,
ontBiasCurrentI OCTET STRING,
ontTemperatureI OCTET STRING,
ontRxCatvPowerI OCTET STRING,
ontTxCatvPowerI OCTET STRING
}
soSlotIndexXV OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontOpticalSwEntry 1 }
soPportIndexXV OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontOpticalSwEntry 2 }
soOntIndexXV OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont, the 3rd index of this table.
Should in <1-128>."
::= { ontOpticalSwEntry 3 }
ontVoltageI OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont power feed voltage(V)."
::= { ontOpticalSwEntry 4 }
ontRXPowerI OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont received optical power(dBm)."
::= { ontOpticalSwEntry 5 }
ontTXPowerI OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont mean optical launch power(dBm)."
::= { ontOpticalSwEntry 6 }
ontBiasCurrentI OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont laser bias current(uA)."
::= { ontOpticalSwEntry 7 }
ontTemperatureI OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont temperature(<28><>C)."
::= { ontOpticalSwEntry 8 }
ontRxCatvPowerI OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont received catv power(dBm)."
::= { ontOpticalSwEntry 9 }
ontTxCatvPowerI OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont transmitted catv power(dBmV)."
::= { ontOpticalSwEntry 10 }
-- ont mac address table ----------------------------------
ontMacAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntMacAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont mac address table"
::= { ontInfo 10 }
ontMacAddrEntry OBJECT-TYPE
SYNTAX OntMacAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont mac address table"
INDEX { ontMacAddrVid, ontMacAddress}
::= { ontMacAddrTable 1 }
OntMacAddrEntry ::=
SEQUENCE
{
ontMacAddrVid INTEGER,
ontMacAddress MacAddress,
ontMacAddrSlot INTEGER,
ontMacAddrPport INTEGER,
ontMacAddrOnt INTEGER,
ontMacAddrSn OCTET STRING,
ontMacAddrGemU INTEGER,
ontMacAddrGem INTEGER
}
ontMacAddrVid OBJECT-TYPE
SYNTAX INTEGER(1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vlan id index of ontMacAddrTable, should in <1-4094>."
::= { ontMacAddrEntry 1 }
ontMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mac address index of ontMacAddrTable."
::= { ontMacAddrEntry 2 }
ontMacAddrSlot OBJECT-TYPE
SYNTAX INTEGER(0..11)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot of ontMacAddrEntry, should in <0-11>.
Should in <1-128>."
::= { ontMacAddrEntry 3 }
ontMacAddrPport OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The pon port of ontMacAddrEntry, should in <1-16>"
::= { ontMacAddrEntry 4 }
ontMacAddrOnt OBJECT-TYPE
SYNTAX INTEGER (1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ont id of ontMacAddrEntry, should in <1-128>"
::= { ontMacAddrEntry 5 }
ontMacAddrSn OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ont sn of ontMacAddrEntry."
::= { ontMacAddrEntry 6 }
ontMacAddrGemU OBJECT-TYPE
SYNTAX INTEGER (0..1024)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ont user gem of ontMacAddrEntry, should in <1-1024>
0: none
1-1024: valid"
::= { ontMacAddrEntry 7 }
ontMacAddrGem OBJECT-TYPE
SYNTAX INTEGER (0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ont gem of ontMacAddrEntry, should in <0-4095>"
::= { ontMacAddrEntry 8 }
-- ont ethernet port infomation ----------------------------
ontEthPortInfo OBJECT IDENTIFIER ::= { statusOnt 2 }
-- 2.4.2.1 ontEthportStateTable
-- 2.4.2.2 ontEthportStatisRecTable
-- 2.4.2.3 ontEthportStatisSentTable
-- 2.4.2.4 ontEthportUtilizationTable
-- ont ethport state table --------------------------------
ontEthportStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntEthportStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont ethport state table"
::= { ontEthPortInfo 1 }
ontEthportStateEntry OBJECT-TYPE
SYNTAX OntEthportStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont ethport state table"
INDEX { soSlotIndexVI, soPportIndexVI, soOntIndexVI, soOntEthportIndex }
::= { ontEthportStateTable 1 }
OntEthportStateEntry ::=
SEQUENCE
{
soSlotIndexVI INTEGER,
soPportIndexVI INTEGER,
soOntIndexVI INTEGER,
soOntEthportIndex INTEGER,
ontEthportAdminStatus OCTET STRING,
ontEthportConnectState OCTET STRING,
ontEthportPortSpeed OCTET STRING
}
soSlotIndexVI OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontEthportStateEntry 1 }
soPportIndexVI OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontEthportStateEntry 2 }
soOntIndexVI OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont, the 3rd index of this table.
Should in <1-128>."
::= { ontEthportStateEntry 3 }
soOntEthportIndex OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont ethernet port, the 4th index of this table.
range <1-n> is determined by ont type, the max n is 2.4."
::= { ontEthportStateEntry 4 }
ontEthportAdminStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont ethernet port admin status:
0 enable
1 disable."
::= { ontEthportStateEntry 5 }
ontEthportConnectState OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont ethernet port connect state."
::= { ontEthportStateEntry 6 }
ontEthportPortSpeed OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont ethernet port speed."
-- 1<><31>2<EFBFBD><32>3 <20>ֱ<EFBFBD><D6B1><EFBFBD>ʮ<EFBFBD>װ<EFBFBD><D7B0><EFBFBD>ǧ<EFBFBD><C7A7>ȫ˫<C8AB><CBAB>
-- 17,18,19 <20>ֱ<EFBFBD><D6B1><EFBFBD>ʮ<EFBFBD>װ<EFBFBD><D7B0><EFBFBD>ǧ<EFBFBD>װ<EFBFBD>˫<EFBFBD><CBAB>
::= { ontEthportStateEntry 7 }
-- ont etherport statistics receive table ----------------------
ontEthportStatisRecTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntEthportStatisRecEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont etherport statistics receive table"
::= { ontEthPortInfo 2 }
ontEthportStatisRecEntry OBJECT-TYPE
SYNTAX OntEthportStatisRecEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont etherport statistics receive table"
INDEX { soSlotIndexVII, soPportIndexVII, soOntIndexVII, soOntEthportIndexI }
::= { ontEthportStatisRecTable 1 }
OntEthportStatisRecEntry ::=
SEQUENCE
{
soSlotIndexVII INTEGER,
soPportIndexVII INTEGER,
soOntIndexVII INTEGER,
soOntEthportIndexI INTEGER,
ontEthportRecFrames INTEGER,
ontEthportRecUniFrames INTEGER,
ontEthportRecMulFrames INTEGER,
ontEthportRecBroFrames INTEGER,
ontEthportRec64Frames INTEGER,
ontEthportRec65Frames INTEGER,
ontEthportRec128Frames INTEGER,
ontEthportRec256Frames INTEGER,
ontEthportRec512Frames INTEGER,
ontEthportRec1024Frames INTEGER,
ontEthportRecUndFrames INTEGER,
ontEthportRecOveFrames INTEGER,
ontEthportRecFragments INTEGER,
ontEthportRecJabbers INTEGER,
ontEthportRecFcsFrames INTEGER,
ontEthportDisFrames INTEGER,
ontEthportRecAliFrames INTEGER,
ontEthportMacRecFrames INTEGER,
ontEthportPppFrames INTEGER,
ontEthportBufReceive INTEGER,
ontEthportRecBytes INTEGER
}
soSlotIndexVII OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontEthportStatisRecEntry 1 }
soPportIndexVII OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontEthportStatisRecEntry 2 }
soOntIndexVII OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont, the 3rd index of this table.
Should in <1-128>."
::= { ontEthportStatisRecEntry 3 }
soOntEthportIndexI OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont ethernet port, the 4th index of this table.
range <1-n> is determined by ont type, the max n is 2.4."
::= { ontEthportStatisRecEntry 4 }
ontEthportRecFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received frames"
::= { ontEthportStatisRecEntry 5 }
ontEthportRecUniFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received unicast frames"
::= { ontEthportStatisRecEntry 6 }
ontEthportRecMulFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received multicast frames"
::= { ontEthportStatisRecEntry 7 }
ontEthportRecBroFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received broadcast frames"
::= { ontEthportStatisRecEntry 8 }
ontEthportRec64Frames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 64-byte frames"
::= { ontEthportStatisRecEntry 9 }
ontEthportRec65Frames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 65~127-byte frames"
::= { ontEthportStatisRecEntry 10 }
ontEthportRec128Frames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 128~255-byte frames"
::= { ontEthportStatisRecEntry 11 }
ontEthportRec256Frames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 256~511-byte frames"
::= { ontEthportStatisRecEntry 12 }
ontEthportRec512Frames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 512~1023-byte frames"
::= { ontEthportStatisRecEntry 13 }
ontEthportRec1024Frames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 1024~1518-byte frames"
::= { ontEthportStatisRecEntry 14 }
ontEthportRecUndFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received undersize frames"
::= { ontEthportStatisRecEntry 15 }
ontEthportRecOveFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received oversize frames"
::= { ontEthportStatisRecEntry 16 }
ontEthportRecFragments OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received fragments"
::= { ontEthportStatisRecEntry 17 }
ontEthportRecJabbers OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received jabbers"
::= { ontEthportStatisRecEntry 18 }
ontEthportRecFcsFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received FCS error frames"
::= { ontEthportStatisRecEntry 19 }
ontEthportDisFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Discard frames"
::= { ontEthportStatisRecEntry 20 }
ontEthportRecAliFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received alignment error frames"
::= { ontEthportStatisRecEntry 21 }
ontEthportMacRecFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC sub-layer received error frames"
::= { ontEthportStatisRecEntry 22 }
ontEthportPppFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PPPOE filtered frames"
::= { ontEthportStatisRecEntry 23 }
ontEthportBufReceive OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Buffer overflows on receive"
::= { ontEthportStatisRecEntry 24 }
ontEthportRecBytes OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received bytes"
::= { ontEthportStatisRecEntry 25 }
-- ont etherport statistics sent table ----------------------
ontEthportStatisSentTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntEthportStatisSentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont etherport statistics sent table"
::= { ontEthPortInfo 3 }
ontEthportStatisSentEntry OBJECT-TYPE
SYNTAX OntEthportStatisSentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont etherport statistics sent table"
INDEX { soSlotIndexXI, soPportIndexXI, soOntIndexXI, soOntEthportIndexIII }
::= { ontEthportStatisSentTable 1 }
OntEthportStatisSentEntry ::=
SEQUENCE
{
soSlotIndexXI INTEGER,
soPportIndexXI INTEGER,
soOntIndexXI INTEGER,
soOntEthportIndexIII INTEGER,
ontEthportSenFrames INTEGER,
ontEthportSenUniFrames INTEGER,
ontEthportSenMulFrames INTEGER,
ontEthportSenBroFrames INTEGER,
ontEthportCarFrames INTEGER,
ontEthportSqeMessages INTEGER,
ontEthportSenSinFrames INTEGER,
ontEthportSenMulColFrames INTEGER,
ontEthportSenExcFrames INTEGER,
ontEthportLatFrames INTEGER,
ontEthportMacSenFrames INTEGER,
ontEthportBufTransmit INTEGER,
ontEthportSentBytes INTEGER
}
soSlotIndexXI OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontEthportStatisSentEntry 1 }
soPportIndexXI OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontEthportStatisSentEntry 2 }
soOntIndexXI OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont, the 3rd index of this table.
Should in <1-128>."
::= { ontEthportStatisSentEntry 3 }
soOntEthportIndexIII OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont ethernet port, the 4th index of this table.
range <1-n> is determined by ont type, the max n is 2.4."
::= { ontEthportStatisSentEntry 4 }
ontEthportSenFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent frames"
::= { ontEthportStatisSentEntry 5 }
ontEthportSenUniFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent unicast frames"
::= { ontEthportStatisSentEntry 6 }
ontEthportSenMulFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent multicast frames"
::= { ontEthportStatisSentEntry 7 }
ontEthportSenBroFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent broadcast frames"
::= { ontEthportStatisSentEntry 8 }
ontEthportCarFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Carrier sense error frames"
::= { ontEthportStatisSentEntry 9 }
ontEthportSqeMessages OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SQE test error messages"
::= { ontEthportStatisSentEntry 10 }
ontEthportSenSinFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent single collision frames"
::= { ontEthportStatisSentEntry 11 }
ontEthportSenMulColFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent multiple collision frames"
::= { ontEthportStatisSentEntry 12 }
ontEthportSenExcFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent excessive collision frames"
::= { ontEthportStatisSentEntry 13 }
ontEthportLatFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Late collision frames"
::= { ontEthportStatisSentEntry 14 }
ontEthportMacSenFrames OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC sub-layer sent error frames"
::= { ontEthportStatisSentEntry 15 }
ontEthportBufTransmit OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Buffer overflows on transmit"
::= { ontEthportStatisSentEntry 16 }
ontEthportSentBytes OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent bytes "
::= { ontEthportStatisSentEntry 17 }
-- ont ethport utilization table ------------------------
ontEthportUtilizationTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntEthportUtilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont ethport multicast mac table"
::= { ontEthPortInfo 4 }
ontEthportUtilizationEntry OBJECT-TYPE
SYNTAX OntEthportUtilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont ethport multicast mac table"
INDEX { soSlotIndexVIII, soPportIndexVIII, soOntIndexVIII, soOntEthportIndexII }
::= { ontEthportUtilizationTable 1 }
OntEthportUtilizationEntry ::=
SEQUENCE
{
soSlotIndexVIII INTEGER,
soPportIndexVIII INTEGER,
soOntIndexVIII INTEGER,
soOntEthportIndexII INTEGER,
soEportUtilizeTxOctetsRate INTEGER,
soEportUtilizeRxOctetsRate INTEGER,
soEportUtilizeTxPktsRate INTEGER,
soEportUtilizeRxPktsRate INTEGER,
soEportUtilizeTxOctets INTEGER,
soEportUtilizeRxOctets INTEGER,
soEportUtilizeTxPktsError INTEGER,
soEportUtilizeRxPktsError INTEGER,
soEportUtilizeTxPktsDiscard INTEGER,
soEportUtilizeRxPktsDiscard INTEGER
}
soSlotIndexVIII OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontEthportUtilizationEntry 1 }
soPportIndexVIII OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontEthportUtilizationEntry 2 }
soOntIndexVIII OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont, the 3rd index of this table.
Should in <1-128>."
::= { ontEthportUtilizationEntry 3 }
soOntEthportIndexII OBJECT-TYPE
SYNTAX INTEGER(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont ethernet port, the 4th index of this table.
range <1-n> is determined by ont type, the max n is 2.4."
::= { ontEthportUtilizationEntry 4 }
soEportUtilizeTxOctetsRate OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont tx octets rate."
::= { ontEthportUtilizationEntry 5 }
soEportUtilizeRxOctetsRate OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont rx octets rate."
::= { ontEthportUtilizationEntry 6 }
soEportUtilizeTxPktsRate OBJECT-TYPE
SYNTAX INTEGER(0..1600000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont tx packets rate(pps)."
::= { ontEthportUtilizationEntry 7 }
soEportUtilizeRxPktsRate OBJECT-TYPE
SYNTAX INTEGER(0..1600000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont rx packets rate(pps)."
::= { ontEthportUtilizationEntry 8 }
soEportUtilizeTxOctets OBJECT-TYPE
SYNTAX INTEGER(0..1600000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont tx octets in 15 minutes."
::= { ontEthportUtilizationEntry 9 }
soEportUtilizeRxOctets OBJECT-TYPE
SYNTAX INTEGER(0..1600000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ont rx octets in 15 minutes."
::= { ontEthportUtilizationEntry 10 }
soEportUtilizeTxPktsError OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port tx packets error in 15 minute."
::= { ontEthportUtilizationEntry 11 }
soEportUtilizeRxPktsError OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port rx packets error in 15 minute."
::= { ontEthportUtilizationEntry 12 }
soEportUtilizeTxPktsDiscard OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port tx packets discard in 15 minute."
::= { ontEthportUtilizationEntry 13 }
soEportUtilizeRxPktsDiscard OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port rx packets discard in 15 minute."
::= { ontEthportUtilizationEntry 14 }
-- ont gemport infomation ----------------------------------
ontGemPortInfo OBJECT IDENTIFIER ::= { statusOnt 3 }
-- 2.4.3.1 ontGemportStatisticsTable
-- ont gemport statistics table ----------------------------
ontGemportStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntGemportStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont gemport statistics table"
::= { ontGemPortInfo 1 }
ontGemportStatisticsEntry OBJECT-TYPE
SYNTAX OntGemportStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont gemport statistics table"
INDEX { soSlotIndexIX, soPportIndexIX, soOntIndexIX, ontGemportStaFrameType, ontGemportStaIndex }
::= { ontGemportStatisticsTable 1 }
OntGemportStatisticsEntry ::=
SEQUENCE
{
soSlotIndexIX INTEGER,
soPportIndexIX INTEGER,
soOntIndexIX INTEGER,
ontGemportStaFrameType INTEGER,
ontGemportStaIndex INTEGER,
ontGemportStaUpdateData INTEGER,
ontGemportLostFrame INTEGER,
ontGemportRecFrame INTEGER,
ontGemportRecBlock INTEGER,
ontGemportSentFrame INTEGER,
ontGemportSentBlock INTEGER
}
soSlotIndexIX OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontGemportStatisticsEntry 1 }
soPportIndexIX OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontGemportStatisticsEntry 2 }
soOntIndexIX OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont, the 3rd index of this table.
Should in <1-128>."
::= { ontGemportStatisticsEntry 3 }
ontGemportStaFrameType OBJECT-TYPE
SYNTAX INTEGER(0..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ontGemportStaFrameTpte:
0----unicast
1----multicast
2----broadcast"
::= { ontGemportStatisticsEntry 4 }
ontGemportStaIndex OBJECT-TYPE
SYNTAX INTEGER(1..24)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ontGemportStaIndex:
The index should be inputed with <1-24>"
::= { ontGemportStatisticsEntry 5 }
ontGemportStaUpdateData OBJECT-TYPE
SYNTAX INTEGER(0..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set ontGemportStaUpdateData=2 to update data of the entry.
then you can read this node. still 2 means update incomplete,
0 means update successfully, 1 means update failed.
If you don't update the data of the entry, the value you get
maybe not newest."
::= { ontGemportStatisticsEntry 6 }
ontGemportLostFrame OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ontGemportLostFrame"
::= { ontGemportStatisticsEntry 7 }
ontGemportRecFrame OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ontGemportRecFrame"
::= { ontGemportStatisticsEntry 8 }
ontGemportRecBlock OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ontGemportRecBlock"
::= { ontGemportStatisticsEntry 9 }
ontGemportSentFrame OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ontGemportSentFrame"
::= { ontGemportStatisticsEntry 10 }
ontGemportSentBlock OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ontGemportSentBlock"
::= { ontGemportStatisticsEntry 11 }
-- ont wan infomation --------------------------------------
ontWanInfo OBJECT IDENTIFIER ::= { statusOnt 4 }
-- 2.4.4.1 ontWanInfoTable
-- ont wan infomation table --------------------------------
ontWanInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntWanInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont wan infomation table"
::= { ontWanInfo 1 }
ontWanInfoEntry OBJECT-TYPE
SYNTAX OntWanInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont wan infomation table"
INDEX { soSlotIndexXIII, soPportIndexXIII, soOntIndexXIII, ontWanIndex}
::= { ontWanInfoTable 1 }
OntWanInfoEntry ::=
SEQUENCE
{
soSlotIndexXIII INTEGER,
soPportIndexXIII INTEGER,
soOntIndexXIII INTEGER,
ontWanIndex INTEGER,
ontWanServerType OCTET STRING,
ontWanIp IpAddress,
ontWanMask IpAddress,
ontWanGateway IpAddress,
ontWanPriDns IpAddress,
ontWanSecDns IpAddress
}
soSlotIndexXIII OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontWanInfoEntry 1 }
soPportIndexXIII OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontWanInfoEntry 2 }
soOntIndexXIII OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont, the 3rd index of this table.
Should in <1-128>."
::= { ontWanInfoEntry 3 }
ontWanIndex OBJECT-TYPE
SYNTAX INTEGER(1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ontWanIndex:
The index should be inputed with <1-4>"
::= { ontWanInfoEntry 4 }
ontWanServerType OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ont wan server type."
-- ҵ<><D2B5><EFBFBD><EFBFBD><EFBFBD><EFBFBD>(IPTV TR069 INTERNET VOIP<49><50><EFBFBD><EFBFBD><EFBFBD>ϣ<EFBFBD><CFA3><EFBFBD>IPTV_TR069_INTERNET_VOIP)
::= { ontWanInfoEntry 5 }
ontWanIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ontGemportLostFrame"
::= { ontWanInfoEntry 6 }
ontWanMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ontGemportRecFrame"
::= { ontWanInfoEntry 7 }
ontWanGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ontGemportRecBlock"
::= { ontWanInfoEntry 8 }
ontWanPriDns OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ontWanInfoEntry"
::= { ontWanInfoEntry 9 }
ontWanSecDns OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ontGemportSentBlock"
::= { ontWanInfoEntry 10 }
-- ont pots infomation --------------------------------------
ontPotsInfo OBJECT IDENTIFIER ::= { statusOnt 5 }
-- 2.4.5.1 ontPotsInfoTable
-- ont pots infomation table --------------------------------
ontPotsInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF OntPotsInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ont pots infomation table"
::= { ontPotsInfo 1 }
ontPotsInfoEntry OBJECT-TYPE
SYNTAX OntPotsInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of ont pots infomation table"
INDEX { soSlotIndexXIV, soPportIndexXIV, soOntIndexXIV, ontPotsIndex}
::= { ontPotsInfoTable 1 }
OntPotsInfoEntry ::=
SEQUENCE
{
soSlotIndexXIV INTEGER,
soPportIndexXIV INTEGER,
soOntIndexXIV INTEGER,
ontPotsIndex INTEGER,
ontPotsStatus INTEGER
}
soSlotIndexXIV OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { ontPotsInfoEntry 1 }
soPportIndexXIV OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of pon port, should in <1-16>."
::= { ontPotsInfoEntry 2 }
soOntIndexXIV OBJECT-TYPE
SYNTAX INTEGER(1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of ont, the 3rd index of this table.
Should in <1-128>."
::= { ontPotsInfoEntry 3 }
ontPotsIndex OBJECT-TYPE
SYNTAX INTEGER(1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ontWanIndex:
The index should be inputed with <1-2>"
::= { ontPotsInfoEntry 4 }
ontPotsStatus OBJECT-TYPE
SYNTAX INTEGER(0..14)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"typedef enum tag_M_ONT_POTS_STATUS
{
/* 0 */ POTS_STATUS_INIT = 0, /* None/initial */
/* 1 */ POTS_STATUS_REGISTERED, /* Registered */
/* 2 */ POTS_STATUS_IN_SESSION, /* In session */
/* 3 */ POTS_STATUS_REG_ICMP_ERR, /* Failed registration <20>Cicmp error */
/* 4 */ POTS_STATUS_REG_TCP_FAIL, /* Failed registration <20>Cfailed tcp */
/* 5 */ POTS_STATUS_REG_TMOUT, /* Failed registration <20>Ctimeout */
/* 6 */ POTS_STATUS_REG_AUTH_FAIL, /* Failed registration - failed authentication */
/* 7 */ POTS_STATUS_REG_SRV_FAIL, /* Failed registration - server fail code */
/* 8 */ POTS_STATUS_INV_ICMP_ERR, /* Failed invite <20>Cicmp error */
/* 9 */ POTS_STATUS_INV_TCP_FAIL, /* Failed invite <20>Cfailed tcp */
/* 10 */ POTS_STATUS_INV_AUTH_FAIL, /* Failed invite <20>Cfailed authentication */
/* 11 */ POTS_STATUS_INV_TMOUT, /* Failed invite <20>Ctimeout */
/* 12 */ POTS_STATUS_INV_SRV_FAIL, /* Failed invite <20>Cserver fail code */
/* 13 */ POTS_STATUS_PORT_NOT_CFG, /* Port not configured */
/* 14 */ POTS_STATUS_CFG_DONE, /* Config done */
POTS_STATUS_SUM
}M_ONT_POTS_STATUS;"
::= { ontPotsInfoEntry 5 }
--------------------------------------------------------------
------------------ 2.5. status trap ------------------------
--------------------------------------------------------------
-- 2.5.1. deviceTrap
-- 2.5.2. slotTrap
-- 2.5.3. portTrap
-- 2.5.4. ontTrap
-- 2.5.5. ontPortTrap
-- 2.5.6. trapInfo
-- 2.5.7. trapSetThreshold
-- 2.5.8. trapClearThreshold
------ deviceTrap ------------------------------------------
deviceTrap OBJECT IDENTIFIER ::= { statusTrap 1 }
oltSwitchOverTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"olt contrl-board switchover trap."
--olt<6C><74><EFBFBD>ذ<EFBFBD><D8B0><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>
::= { deviceTrap 1 }
oltFanStatusTrap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapExtraInfo }
STATUS current
DESCRIPTION
"olt fan status change trap.
gponTrapExtraInfo:
1 stop
2 start
3 remove
4 insert"
--olt<6C><74><EFBFBD><EFBFBD>״̬trap
::= { deviceTrap 2 }
oltPowerStatusTrap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapExtraInfo }
STATUS current
DESCRIPTION
"olt power status trap."
--olt<6C><74>Դ״̬trap true
::= { deviceTrap 3 }
oltTemperatureTrap NOTIFICATION-TYPE
OBJECTS { gponTrapStatus, gponTrapExtraInfo }
STATUS current
DESCRIPTION
"olt switch chip temperature trap.
gponTrapExtraInfo:
1 low
2 high"
--olt <20><><EFBFBD><EFBFBD>оƬ<D0BE><EFBFBD>trap true
::= { deviceTrap 4 }
oltPonTemperatureTrap NOTIFICATION-TYPE
OBJECTS { gponTrapStatus, gponTrapExtraInfo }
STATUS current
DESCRIPTION
"olt pon chip temperature trap.
gponTrapExtraInfo:
1 low
2 high"
--olt pon оƬ<D0BE><EFBFBD>trap true
::= { deviceTrap 5 }
unitOfflineAlarmTrap NOTIFICATION-TYPE
OBJECTS { gponTrapStatus }
STATUS current
DESCRIPTION
"unit offline alarm trap."
--olt offline <20>澯 true
::= { deviceTrap 6 }
oltDgTrap NOTIFICATION-TYPE
OBJECTS { gponTrapStatus }
STATUS current
DESCRIPTION
"unit dying gasp trap."
--olt <20><><EFBFBD><EFBFBD><EFBFBD>
::= { deviceTrap 7 }
edfaTrap NOTIFICATION-TYPE
OBJECTS { gponTrapExtraInfo, gponTrapSfpPerformanceStatus }
STATUS current
DESCRIPTION
"edfa trap.
gponTrapExtraInfo:
1 Optical Input Power 1
2 Optical Input Power 2
3 Optical Output Power
4 Pump 1 Bias Current
5 Pump 1 Pump Temperature
6 Pump 1 Pump Tec
7 Pump 2 Bias Current
8 Pump 2 Pump Temperature
9 Pump 2 Pump Tec
10 DC Voltage
11 Internal Temperature"
::= { deviceTrap 8 }
oltDooralmTrap NOTIFICATION-TYPE
OBJECTS { gponTrapStatus }
STATUS current
DESCRIPTION
"olt door alarm trap."
--olt <20><><EFBFBD><EFBFBD><EFBFBD>
::= { deviceTrap 9 }
warningPortAlarmTrap NOTIFICATION-TYPE
OBJECTS { gponTrapWarnPortIndex, gponTrapWarnPortAlarm }
STATUS current
DESCRIPTION
"Warning port alarm."
--olt <20><EFBFBD>˿ڸ澯
::= { deviceTrap 10 }
------ slotTrap --------------------------------------------
slotTrap OBJECT IDENTIFIER ::= { statusTrap 2 }
oltBoardStatusTrap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapExtraInfo }
STATUS current
DESCRIPTION
"olt board status trap."
--olt <20><>״̬<D7B4>ı<C4B1><E4A3A8><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>أ<EFBFBD>ҵ<EFBFBD><D2B5><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>Ƴ<EFBFBD><C6B3><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ӣ<EFBFBD>
::= { slotTrap 1 }
------ portTrap ------------------------------------------
portTrap OBJECT IDENTIFIER ::= { statusTrap 3 }
oltPortRingTrap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapPortId, gponTrapStatus }
STATUS current
DESCRIPTION
"olt port ring trap."
--olt<6C>˿ڻ<CBBF>·trap
::= { portTrap 1 }
oltPortSdTrap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapPortId, gponTrapStatus }
STATUS current
DESCRIPTION
"olt port sd trap."
--olt<6C>˿<EFBFBD> sd trap true
::= { portTrap 2 }
oltPportLOSTrap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapPortId, gponTrapStatus }
STATUS current
DESCRIPTION
"olt pon port LOS trap. "
--olt pon <20>˿<EFBFBD> LOS trap true
::= { portTrap 3 }
oltPortSfpTcrossTrap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapPortId, gponTrapOntId, gponTrapStatus, gponTrapExtraInfo }
STATUS current
DESCRIPTION
"olt sfp threshold crossing alert trap.
gponTrapExtraInfo:
1 recieve high
2 recieve low
3 send high
4 send low"
--olt <20><>ģ<EFBFBD><C4A3><EFBFBD><EFBFBD><EFBFBD><EFBFBD>Խ<EFBFBD>޸澯 trap
::= { portTrap 4 }
oltPortSfpUnplugTrap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapPortId, gponTrapStatus, gponTrapSn }
STATUS current
DESCRIPTION
"olt pon port sfp unplug trap. "
--olt pon <20>˿ڹ<CBBF>ģ<EFBFBD><EFBFBD>γ<EFBFBD> trap true
::= { portTrap 5 }
oltPortUdldTrap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapPortId, gponTrapExtraInfo }
STATUS current
DESCRIPTION
"UniDirectional Link Detection trap.
gponTrapExtraInfo:
1 Undetermined
2 Unidirectional
3 Bidirectional"
--olt <20>˿ڵ<CBBF><DAB5><EFBFBD><EFBFBD><EFBFBD>·<EFBFBD><C2B7><EFBFBD><EFBFBD> trap true
-- 1 δȷ<CEB4><C8B7> 2 <20><>ͨ 3 ˫ͨ
::= { portTrap 6 }
oltPportLOFTrap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapPortId, gponTrapStatus }
STATUS current
DESCRIPTION
"olt pon port LOF trap. "
--olt pon <20>˿<EFBFBD> LOF trap true
::= { portTrap 7 }
oltPortCRCTrap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapPortId, gponTrapStatus }
STATUS current
DESCRIPTION
"olt port CRC trap. "
--olt <20>˿<EFBFBD> CRC trap
::= { portTrap 8 }
oltPportRegOverTrap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapPortId, gponTrapStatus }
STATUS current
DESCRIPTION
"olt pon port register over trap. "
--olt pon <20>˿<EFBFBD>ע<EFBFBD><D7A2><EFBFBD><EFBFBD><EFBFBD><EFBFBD>Խ<EFBFBD><D4BD> trap
::= { portTrap 9 }
------ ontTrap --------------------------------------------
ontTrap OBJECT IDENTIFIER ::= { statusTrap 4 }
ontOnlineStatusTrap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapPortId, gponTrapOntId, gponTrapStatus, gponTrapSn, gponTrapLoid }
STATUS current
DESCRIPTION
"ont online status trap."
--ont<6E><74><EFBFBD><EFBFBD><EFBFBD><EFBFBD>״̬trap true
::= { ontTrap 1 }
ont9843Trap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapPortId, gponTrapOntId, gponTrapExtraInfo }
STATUS current
DESCRIPTION
"ont 984.3 warning trap.
gponTrapExtraInfo: warning type:
1 LOSi
2 LOFi
3 DOWi
4 SFi
5 SDi
6 LCDGi
7 RDIi
8 SUFi
9 DFi
10 LOAi
11 LOKi
12 TIWi
13 DGi
14 LOAMi
15 MEMi
16 MISi
17 PEEi
18 ERRi
19 REIi"
--ont 984.3 <20>澯 trap true
::= { ontTrap 2 }
ontRogueTrap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapPortId, gponTrapOntId, gponTrapStatus, gponTrapExtraInfo }
STATUS current
DESCRIPTION
"Rogue ont trap.
gponTrapExtraInfo: rogue type:
1 continuous
2 intermittent "
--<2D><>åont trap<61><70><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ͼ<EFBFBD>Ъ<EFBFBD>Է<EFBFBD><D4B7>
::= { ontTrap 3 }
ontAuthFailTrap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapPortId, gponTrapSn }
STATUS current
DESCRIPTION
"ont authentication failure trap."
--ont<6E><74>֤ʧ<D6A4><CAA7>trap
::= { ontTrap 4 }
ontSfpTcrossTrap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapPortId, gponTrapOntId, gponTrapStatus, gponTrapExtraInfo }
STATUS current
DESCRIPTION
"ont sfp threshold crossing alert trap.
gponTrapExtraInfo:
1 recieve high
2 recieve low
3 send high
4 send low"
--olt <20><>ģ<EFBFBD><C4A3><EFBFBD><EFBFBD><EFBFBD><EFBFBD>Խ<EFBFBD>޸澯 trap
::= { ontTrap 5 }
------ ontPortTrap ------------------------------------------
ontPortTrap OBJECT IDENTIFIER ::= { statusTrap 5 }
ontEthPortStatusTrap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapPortId, gponTrapOntId, gponTrapOntEthportId, gponTrapStatus }
STATUS current
DESCRIPTION
"ont ethernet port status trap."
--ont<6E><74>̫<EFBFBD><CCAB><EFBFBD>˿<EFBFBD>״̬trap
::= { ontPortTrap 1 }
ontEthPortRingTrap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapPortId, gponTrapOntId, gponTrapOntEthportId, gponTrapStatus }
STATUS current
DESCRIPTION
"ont ethernet port ring trap."
--ont<6E><74>̫<EFBFBD><CCAB><EFBFBD>˿ڻ<CBBF>·trap
::= { ontPortTrap 2 }
ontPotsH248Trap NOTIFICATION-TYPE
OBJECTS { gponTrapSlotId, gponTrapPortId, gponTrapOntId, gponTrapExtraId, gponTrapStatus }
STATUS current
DESCRIPTION
"ont pots h248 link trap.
gponTrapExtraId: ont pots number"
--ont<6E><74><EFBFBD><EFBFBD><EFBFBD>˿<EFBFBD><CBBF><EFBFBD>·<EFBFBD>澯trap
::= { ontPortTrap 3 }
------ trapInfo --------------------------------------
trapInfo OBJECT IDENTIFIER ::= { statusTrap 6 }
gponTrapSlotId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"slot-id/fan-id/power-id in trap "
::= { trapInfo 1 }
gponTrapPortId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"port id in trap "
::= { trapInfo 2 }
gponTrapOntId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"ont id in trap "
::= { trapInfo 3 }
gponTrapOntEthportId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"ont ethernet port id in trap "
::= { trapInfo 4 }
gponTrapExtraId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"other id in trap, etc."
::= { trapInfo 5 }
gponTrapStatus OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"1 alarm/linkdown/offline/open box
0 clear/linkup/online/close box"
::= { trapInfo 6 }
gponTrapExtraInfo OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"trap extra infomation"
::= { trapInfo 7 }
gponTrapSn OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"sn use for trap."
::= { trapInfo 8 }
gponTrapLoid OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"sn use for trap."
::= { trapInfo 9 }
gponTrapSfpPerformanceStatus OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"0 normal
1 lolo
2 lo
3 hi
4 hihi"
::= { trapInfo 10 }
gponTrapWarnPortIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Warn index 1 to 8"
::= { trapInfo 11 }
gponTrapWarnPortAlarm OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"0 clear
1 warn"
::= { trapInfo 12 }
------ trapSetThreshold --------------------------------------
trapSetThreshold OBJECT IDENTIFIER ::= { statusTrap 7 }
thresholdTemperatureHigh OBJECT-TYPE
SYNTAX INTEGER (-99..99)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"temperature high threshold, default 60(<28><>)."
::= { trapSetThreshold 1 }
thresholdTemperatureLow OBJECT-TYPE
SYNTAX INTEGER (-99..99)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"temperature low threshold, default -25(<28><>)."
::= { trapSetThreshold 2 }
thresholdRegOnt OBJECT-TYPE
SYNTAX INTEGER (0..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ont register number threshold, default 64."
::= { trapSetThreshold 3 }
edfaThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF EdfaThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"edfa threshold table"
::= { trapSetThreshold 4 }
edfaThresholdEntry OBJECT-TYPE
SYNTAX EdfaThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of edfa threshold table"
INDEX { tntitInputId }
::= { edfaThresholdTable 1 }
EdfaThresholdEntry ::=
SEQUENCE
{
edfaTrapIndex INTEGER,
edfaTrapDescription OCTET STRING,
edfaTrapEnableSwitch INTEGER,
edfaThresholdLoLo OCTET STRING,
edfaThresholdLo OCTET STRING,
edfaThresholdHi OCTET STRING,
edfaThresholdHiHi OCTET STRING
}
edfaTrapIndex OBJECT-TYPE
SYNTAX INTEGER(1..11)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of edfa trap, see gponTrapExtraInfo in edfaTrap description."
::= { edfaThresholdEntry 1 }
edfaTrapDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of edfa trap, see gponTrapExtraInfo in edfaTrap description."
::= { edfaThresholdEntry 2 }
edfaTrapEnableSwitch OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"edfaTrapEnableSwitch:
0 disable
1 enable."
::= { edfaThresholdEntry 3 }
edfaThresholdLoLo OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"edfa threshold lolo."
::= { edfaThresholdEntry 4 }
edfaThresholdLo OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"edfa threshold lo."
::= { edfaThresholdEntry 5 }
edfaThresholdHi OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"edfa threshold hi."
::= { edfaThresholdEntry 6 }
edfaThresholdHiHi OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"edfa threshold hihi."
::= { edfaThresholdEntry 7 }
------ trapClearThreshold --------------------------------------
trapClearThreshold OBJECT IDENTIFIER ::= { statusTrap 8 }
--------------------------------------------------------------
------------------ 3. oemTrue ------------------------------
--------------------------------------------------------------
trueXmlOntConfig OBJECT IDENTIFIER ::= { oemTrue 1 }
txocSlotId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ont slot id. "
::= { trueXmlOntConfig 1 }
txocPportId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ont pport id. "
::= { trueXmlOntConfig 2 }
txocOntId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ont id. "
::= { trueXmlOntConfig 3 }
txocServerIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"xml tftp server ip address."
::= { trueXmlOntConfig 4 }
txocSn OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"xml sn."
::= { trueXmlOntConfig 5 }
txocCrc OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"xml crc. "
::= { trueXmlOntConfig 6 }
trueNameToIndex OBJECT IDENTIFIER ::= { oemTrue 2 }
-- <20><>ģ<EFBFBD><C4A3><EFBFBD><EFBFBD><EFBFBD><EFBFBD>ת<EFBFBD><D7AA><EFBFBD><EFBFBD> index
tntiName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"profile name."
::= { trueNameToIndex 1 }
tntiType OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"tntiType:
1 dba
2 vlan
3 us traffic
4 ds traffic
5 line
6 rule
7 unique."
::= { trueNameToIndex 2 }
tntiStatus OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"tntiStatus:
1 exist
2 not exist
3 full(& not exist)."
::= { trueNameToIndex 3 }
tntiIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1. if tntiStatus is 1(exist), tntiIndex is the index of tntiName.
2. if tntiStatus is 2(not exist), tntiIndex is the index of an empty entry.
3. if titiStatus is 3(full), tntiIndex is M_INVALID((ulong)-20)."
::= { trueNameToIndex 4 }
-- true name to index table ----------------------------------
trueNameToIndexTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrueNameToIndexEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"true name to index table"
::= { oemTrue 3 }
trueNameToIndexEntry OBJECT-TYPE
SYNTAX TrueNameToIndexEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of true name to index table"
INDEX { tntitInputId }
::= { trueNameToIndexTable 1 }
TrueNameToIndexEntry ::=
SEQUENCE
{
tntitInputId INTEGER,
tntitName OCTET STRING,
tntitType INTEGER,
tntitStatus INTEGER,
tntitProfileId INTEGER
}
tntitInputId OBJECT-TYPE
SYNTAX INTEGER(0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of socket, should in <0-4294967295>."
::= { trueNameToIndexEntry 1 }
tntitName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"profile name."
::= { trueNameToIndexEntry 2 }
tntitType OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"tntiType:
1 dba
2 vlan
3 us traffic
4 ds traffic
5 line
6 rule
7 unique."
::= { trueNameToIndexEntry 3 }
tntitStatus OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"tntiStatus:
1 exist
2 not exist
3 full(& not exist)."
::= { trueNameToIndexEntry 4 }
tntitProfileId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1. if tntiStatus is 1(exist), tntitProfileId is the index of tntiName.
2. if tntiStatus is 2(not exist), tntitProfileId is the index of an empty entry.
3. if titiStatus is 3(full), tntitProfileId is M_INVALID((ulong)-20)."
::= { trueNameToIndexEntry 5 }
--------------------------------------------------------------
------------------ 4. gponSwitch --------------------------
--------------------------------------------------------------
gponUdld OBJECT IDENTIFIER ::= { gponSwitch 1 }
gponPower OBJECT IDENTIFIER ::= { gponSwitch 2 }
gponFan OBJECT IDENTIFIER ::= { gponSwitch 3 }
-- gpon udld if table ----------------------------------
gponUdldIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF GponUdldIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"gpon udld if table"
::= { gponUdld 1 }
gponUdldIfEntry OBJECT-TYPE
SYNTAX GponUdldIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of gpon udld if table"
INDEX { guIfSlotIndex, guIfEportIndex }
::= { gponUdldIfTable 1 }
GponUdldIfEntry ::=
SEQUENCE
{
guIfSlotIndex INTEGER,
guIfEportIndex INTEGER,
guIfWorkmode INTEGER
}
guIfSlotIndex OBJECT-TYPE
SYNTAX INTEGER(0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of slot, should in <0-5>."
::= { gponUdldIfEntry 1 }
guIfEportIndex OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of eth port, should in <1-16>."
::= { gponUdldIfEntry 2 }
guIfWorkmode OBJECT-TYPE
SYNTAX INTEGER(0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"guIfWorkmode:
0 normal
1 aggressive."
::= { gponUdldIfEntry 3 }
guDelaydownTime OBJECT-TYPE
SYNTAX INTEGER(1..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"udld delaydown-time, default 1(s). "
::= { gponUdld 2 }
-- gpon udld if table ----------------------------------
gponPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF GponPowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"gpon power table"
::= { gponPower 1 }
gponPowerEntry OBJECT-TYPE
SYNTAX GponPowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of gpon power table"
INDEX { powerIndex }
::= { gponPowerTable 1 }
GponPowerEntry ::=
SEQUENCE
{
powerIndex INTEGER,
powerInsertedStaus INTEGER,
powerRunningStatus INTEGER
}
powerIndex OBJECT-TYPE
SYNTAX INTEGER {
power_0(0),
power_1(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power index."
::= { gponPowerEntry 1 }
powerInsertedStaus OBJECT-TYPE
SYNTAX INTEGER {
empty(0),
inserted(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power inserted status."
::= { gponPowerEntry 2 }
powerRunningStatus OBJECT-TYPE
SYNTAX INTEGER {
no_good(0),
good(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power running status."
::= { gponPowerEntry 3 }
gponFanInsertStatus OBJECT-TYPE
SYNTAX INTEGER {
empty(0),
insert(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fan insert status. "
::= { gponFan 1 }
gponFanTable OBJECT-TYPE
SYNTAX SEQUENCE OF GponFanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"gpon fan table"
::= { gponFan 2 }
gponFanEntry OBJECT-TYPE
SYNTAX GponFanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"entry of gpon fan table"
INDEX { fanIndex }
::= { gponFanTable 1 }
GponFanEntry ::=
SEQUENCE
{
fanIndex INTEGER,
fanSpeed INTEGER
}
fanIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fan index."
::= { gponFanEntry 1 }
fanSpeed OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fan speed in rpm."
::= { gponFanEntry 2 }
END