98 lines
3.4 KiB
Plaintext
98 lines
3.4 KiB
Plaintext
ELTEX-MES-IpRouter DEFINITIONS ::= BEGIN
|
|
|
|
-- Title: Eltex MES IP Router Private Extension
|
|
-- Version: 1.1
|
|
-- Date: 29 Mar 2018
|
|
|
|
-- OSPF md5 authentication table
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE,
|
|
MODULE-IDENTITY FROM SNMPv2-SMI
|
|
eltMesOspf FROM ELTEX-MES-IP
|
|
rlOspfGeneralGroupEntry FROM RADLAN-OSPF-MIB
|
|
Unsigned32, IpAddress FROM SNMPv2-SMI
|
|
RowStatus FROM SNMPv2-TC
|
|
AreaID FROM OSPF-MIB;
|
|
|
|
--
|
|
-- eltOspfGeneralGroupTable
|
|
--
|
|
|
|
eltOspfGeneralGroupTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EltOspfGeneralGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table augments existing rlOspfGeneralGroupTable."
|
|
::= { eltMesOspf 4 }
|
|
|
|
eltOspfGeneralGroupEntry OBJECT-TYPE
|
|
SYNTAX EltOspfGeneralGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Information describing the configured global parame-
|
|
ters to the Router OSPF Process."
|
|
AUGMENTS { rlOspfGeneralGroupEntry }
|
|
::= { eltOspfGeneralGroupTable 1 }
|
|
|
|
EltOspfGeneralGroupEntry ::=
|
|
SEQUENCE {
|
|
eltOspfLsaMinInterval Unsigned32,
|
|
eltOspfLsaHoldInterval Unsigned32,
|
|
eltOspfLsaMaxInterval Unsigned32,
|
|
eltOspfLsaMinArrival Unsigned32
|
|
}
|
|
|
|
eltOspfLsaMinInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..600000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum time, in milliseconds, between distinct
|
|
originations of any particular LSA."
|
|
DEFVAL { 5000 }
|
|
::= { eltOspfGeneralGroupEntry 1 }
|
|
|
|
eltOspfLsaHoldInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..600000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time, in milliseconds, that the minimum time between
|
|
distinct originations of any particular LSA is increased
|
|
when the network is unstable.
|
|
|
|
If an event occurs within the minimum time for LSA
|
|
regeneration, the origination is delayed until the end of
|
|
the eltOspfLsaHoldInterval and the length of the interval
|
|
doubled. Doubling of the hold interval contuinues until
|
|
the interval reaches eltOspfLsaMaxInterval."
|
|
DEFVAL { 0 }
|
|
::= { eltOspfGeneralGroupEntry 2 }
|
|
|
|
eltOspfLsaMaxInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..600000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum value, in milliseconds, that an origination of
|
|
any particular LSA is delayed."
|
|
DEFVAL { 0 }
|
|
::= { eltOspfGeneralGroupEntry 3 }
|
|
|
|
eltOspfLsaMinArrival OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..600000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For any particular LSA, the minimum time in milliseconds
|
|
that must elapse between reception of new LSA instances
|
|
during flooding. LSA instances received at higher
|
|
frequencies are discarded."
|
|
DEFVAL { 1000 }
|
|
::= { eltOspfGeneralGroupEntry 4 }
|
|
|
|
END
|