Observium_CE/mibs/ekinops/EKINOPS-Pmora14-MIB

2011 lines
51 KiB
Plaintext
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

-- *****************************************************************
-- EKINOPS-pmora14.TXT: MIB
--
--MIB Part Number:3MI00216AAAB
--MIB Version:01
--
-- Copyright (c) 2016 by Ekinops
-- All rights reserved.
--
-- *****************************************************************
EKINOPS-Pmora14-MIB DEFINITIONS ::= BEGIN
IMPORTS
ekinops,
EkiState,
EkiOnOff,
EkiMode,
EkiProtocol,
EkiApiState,
EkiSynchroMode,
EkiMeasureType
FROM EKINOPS-MIB
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Unsigned32,
Integer32,
Counter32,
IpAddress
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
DisplayString
FROM SNMPv2-TC;
modulepmora14 MODULE-IDENTITY
LAST-UPDATED "201605230000Z"
ORGANIZATION "Ekinops"
CONTACT-INFO
"Ekinops
3, rue Blaise Pascal
F-22300 Lannion / FRANCE
Tel : +33 (0)2 96 05 00 30
Fax : +33 (0)2 96 48 62 39
E-mail: support@ekinops.net"
DESCRIPTION
"Creation"
REVISION "201508310000Z"
DESCRIPTION
"Creation"
REVISION "201605230000Z"
DESCRIPTION
"New AlarmType synthesisAlarm (12)"
::= { ekinops 72 }
--- *****************************************************
--- LEAF LEVEL 2
--- *****************************************************
pmora14alarms OBJECT IDENTIFIER ::= { modulepmora14 2 }
pmora14AlmOther OBJECT IDENTIFIER ::= { pmora14alarms 1 }
pmora14AlmOtherNurg OBJECT IDENTIFIER ::= { pmora14AlmOther 1 }
pmora14AlmOtherUrg OBJECT IDENTIFIER ::= { pmora14AlmOther 2 }
pmora14AlmOtherCrit OBJECT IDENTIFIER ::= { pmora14AlmOther 3 }
pmora14AlmClient OBJECT IDENTIFIER ::= { pmora14alarms 2 }
pmora14AlmClientNurg OBJECT IDENTIFIER ::= { pmora14AlmClient 1 }
pmora14AlmClientUrg OBJECT IDENTIFIER ::= { pmora14AlmClient 2 }
pmora14AlmClientCrit OBJECT IDENTIFIER ::= { pmora14AlmClient 3 }
pmora14AlmLine OBJECT IDENTIFIER ::= { pmora14alarms 3 }
pmora14AlmLineNurg OBJECT IDENTIFIER ::= { pmora14AlmLine 1 }
pmora14AlmLineUrg OBJECT IDENTIFIER ::= { pmora14AlmLine 2 }
pmora14AlmLineCrit OBJECT IDENTIFIER ::= { pmora14AlmLine 3 }
pmora14measures OBJECT IDENTIFIER ::= { modulepmora14 3 }
pmora14MesrOther OBJECT IDENTIFIER ::= { pmora14measures 1 }
pmora14MesrClient OBJECT IDENTIFIER ::= { pmora14measures 2 }
pmora14MesrLine OBJECT IDENTIFIER ::= { pmora14measures 3 }
pmora14counters OBJECT IDENTIFIER ::= { modulepmora14 4 }
pmora14CntOther OBJECT IDENTIFIER ::= { pmora14counters 1 }
pmora14CntClient OBJECT IDENTIFIER ::= { pmora14counters 2 }
pmora14CntLine OBJECT IDENTIFIER ::= { pmora14counters 3 }
pmora14controlsWrite OBJECT IDENTIFIER ::= { modulepmora14 6 }
pmora14CtrlOther OBJECT IDENTIFIER ::= { pmora14controlsWrite 1 }
pmora14CtrlClient OBJECT IDENTIFIER ::= { pmora14controlsWrite 2 }
pmora14CtrlLine OBJECT IDENTIFIER ::= { pmora14controlsWrite 3 }
pmora14ri OBJECT IDENTIFIER ::= { modulepmora14 7 }
pmora14riTable OBJECT IDENTIFIER ::= { pmora14ri 1 }
pmora14Config OBJECT IDENTIFIER ::= { modulepmora14 9 }
pmora14traps OBJECT IDENTIFIER ::= { modulepmora14 10 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- TEXTUAL-CONVENTION
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
Pmora14PumpsMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different modes on the Raman Module"
SYNTAX INTEGER {
ora14maxpowermode(0),
ora14gaincontrolmode(1),
ora14manualcontrolmode(2)
}
Pmora14AprMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different modes on APR"
SYNTAX INTEGER {
ora14aproffmode(0),
ora14aproscmode(1),
ora14aprbrratiomode(2)
ora14aprsbandmode(3)
ora14aprfullmode(4)
}
Pmora14LineFiberTypeMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different modes on APR"
SYNTAX INTEGER {
ora14g652mode(0),
ora14g655leafmode(1),
ora14g655truewavemode(2)
ora14g654mode(3)
ora14g653mode(4)
}
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- REMOTE INVENTORY
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
pmora14RinvReloadInventory OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reload the inventory: This OID triggers an
inventory reload."
::= { pmora14ri 2 }
pmora14RinvHwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HW platform description: This OID contains the
description of the Hardware platform."
::= { pmora14ri 3 }
pmora14RinvModulePlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module platform description: This OID contains the
description of the Module."
::= { pmora14ri 4 }
pmora14RinvSwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SW platform description: This OID contains the
description of the Software platform."
::= { pmora14ri 5 }
pmora14RinvGwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"GW platform description: This OID contains the
description of the gateware platform."
::= { pmora14ri 6 }
pmora14RinvLineTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pmora14RinvLineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of the Lines on the selected module"
::= { pmora14riTable 2 }
pmora14RinvLineEntry OBJECT-TYPE
SYNTAX Pmora14RinvLineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for the Line table"
INDEX { pmora14RinvLineIndex }
::= { pmora14RinvLineTable 1 }
Pmora14RinvLineEntry::=
SEQUENCE {
pmora14RinvLineIndex
Integer32,
pmora14RinvportLine
DisplayString
}
pmora14RinvLineIndex OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for Line table"
::= { pmora14RinvLineEntry 1 }
pmora14RinvportLine OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Inventory for the Line: This OID contains the inventory for the Line"
::= { pmora14RinvLineEntry 2 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- ALARMS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the synthAlm0 article
--- *****************************************************
pmora14AlmsynthAlm0 OBJECT IDENTIFIER ::= { pmora14AlmOtherCrit 0 }
pmora14AlmDefFuseB OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse B Fail :This OID indicates
that the fuse of the power input
B is in fail condition <Help>
Status of the Fuse B <Condtype>
DEF_FUSE_B <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmora14AlmsynthAlm0 16 }
pmora14AlmDefFuseA OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse A Fail :This OID indicates
that the fuse of the power input
A is in fail condition <Help>
Status of the Fuse A <Condtype>
DEF_FUSE_A <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmora14AlmsynthAlm0 15 }
pmora14AlmInitNotCompl OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Raman Module Not Initialized :This
OID indicates that the initialisation
of the Raman module is not completed
<Help> This status indicates
if the Raman has been correctly
initialized <Condtype> INIT_NOT_COMPL
<Probcause> equipmentMalfunction
(16) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmora14AlmsynthAlm0 10 }
pmora14AlmModGlobFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Failure :This OID is set
on detection of a failure originating
from the PM <Help> This alarm
<Condtype> MOD_GLOB_FAIL <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmora14AlmsynthAlm0 9 }
pmora14AlmAprOn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Automatic Power Reduction :This
OID indicates that the APR algorithm
has been operated and the output
of the lasers are shutdown <Help>
The APR algorithm has been completed
<Condtype> APR_ON <Probcause>
other (1) <Alarmtype> other (1)
<Polarity> (2)
"
::= { pmora14AlmsynthAlm0 2 }
pmora14AlmMaintenanceMode OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Maintenance Mode :This OID indicates
that the PM is in maintenance mode
<Help> This status indiates
if the module is currently in
maintenance mode <Condtype> MAINTENANCE_MODE
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmora14AlmsynthAlm0 1 }
--- *****************************************************
--- LEAF for the synthAlm2 article
--- *****************************************************
pmora14AlmsynthAlm2 OBJECT IDENTIFIER ::= { pmora14AlmOtherNurg 2 }
pmora14AlmConfTableLoad OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
PM Configuration Load :This OID
is at 1 during the loading of
configuration tables in the modules
RAM. <Condtype> CONF_TABLE_LOAD
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmora14AlmsynthAlm2 3 }
pmora14AlmInvUpload OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Inventory Upload :This OID is
at 1 during the uploading of PM
inventory information. <Condtype>
INV_UPLOAD <Probcause> other (1)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pmora14AlmsynthAlm2 2 }
pmora14AlmConfTableSave OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
PM Configuration Save :This OID
is at 1 during the saving of a
new configuration table in the
module Flash memory. <Condtype>
CONF_TABLE_SAVE <Probcause> other
(1) <Alarmtype> other (1) <Polarity>
(2)
"
::= { pmora14AlmsynthAlm2 1 }
--- *****************************************************
--- LEAF for the synthAlm7 article
--- *****************************************************
pmora14AlmsynthAlm7 OBJECT IDENTIFIER ::= { pmora14AlmLineUrg 7 }
pmora14AlmLineFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Port Failure :This OID indicates
a failure on the line port <Help>
This alarm indicates a failure
on the Line port <Condtype> LINE_FAIL
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmora14AlmsynthAlm7 12 }
pmora14AlmPumpsTxOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pumps Laser Shutdown :This OID
indicates the power of the pumps
are both on <Help> This status
indicates if the pumps lasers are
both OFF <Condtype> PUMPS_TX_OFF
<Probcause> pumpFailure (39) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmora14AlmsynthAlm7 5 }
pmora14AlmLineHwFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Port HW Failure :This OID
indicates a failure on line port,
most probably caused by a HW issue
<Help> This alarm indicates a failure
on the HW Line port <Condtype>
LINE_HW_FAIL <Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmora14AlmsynthAlm7 4 }
--- *****************************************************
--- LEAF for the clientOraAlarms1 article
--- *****************************************************
pmora14AlmclientOraAlarms1 OBJECT IDENTIFIER ::= { pmora14AlmLineUrg 32 }
pmora14AlmPump2TecAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 2 TEC Alarm :This OID indicates
a transmit laser fail on pump 2
<Help> This alarm indicates if
the laser of the pump2 is in fail
condition <Condtype> PUMP2_TEC_ALARM
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmora14AlmclientOraAlarms1 4 }
pmora14AlmPump1TecAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 1 TEC Alarm :This OID indicates
a transmit laser fail on pump 1
<Help> This alarm indicates if
the laser of the pump1 is in fail
condition <Condtype> PUMP1_TEC_ALARM
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmora14AlmclientOraAlarms1 3 }
pmora14AlmPump2CurrentHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 2 Current High Alarm :This
OID indicates the Pump2 current
is higher than the alarm threshold
<Help> This alarm indicates if
the pump2 current is higher than
the alarm threshold <Condtype>
PUMP2_CURRENT_HIGH_ALARM <Probcause>
performanceDegraded (35) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmora14AlmclientOraAlarms1 2 }
pmora14AlmPump1CurrentHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 1 Current High Alarm :This
OID indicates the Pump1 current
is higher than the alarm threshold
<Help> This alarm indicates if
the pump1 current is higher than
the alarm threshold <Condtype>
PUMP1_CURRENT_HIGH_ALARM <Probcause>
performanceDegraded (35) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmora14AlmclientOraAlarms1 1 }
--- *****************************************************
--- LEAF for the clientOraaWarnings article
--- *****************************************************
pmora14AlmclientOraaWarnings OBJECT IDENTIFIER ::= { pmora14AlmLineNurg 33 }
pmora14AlmPump2TecWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 2 TEC Warning :This OID indicates
a transmit laser fail on pump 2
<Help> This alarm indicates if
the laser of the pump2 is in fail
condition <Condtype> PUMP2_TEC_WARNING
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmora14AlmclientOraaWarnings 4 }
pmora14AlmPump1TecWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 1 TEC Warning :This OID indicates
a transmit laser fail on pump 1
<Help> This alarm indicates if
the laser of the pump1 is in fail
condition <Condtype> PUMP1_TEC_WARNING
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmora14AlmclientOraaWarnings 3 }
pmora14AlmPump2CurrentHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 2 Current High Warning :This
OID indicates the Pump2 current
is higher than the warning threshold
<Help> This alarm indicates if
the pump2 current is higher than
the warning threshold <Condtype>
PUMP2_CURRENT_HIGH_WARNING <Probcause>
performanceDegraded (35) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmora14AlmclientOraaWarnings 2 }
pmora14AlmPump1CurrentHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 1 Current High Warning :This
OID indicates the Pump1 current
is higher than the warning threshold
<Help> This alarm indicates if
the pump1 current is higher than
the warning threshold <Condtype>
PUMP1_CURRENT_HIGH_WARNING <Probcause>
performanceDegraded (35) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmora14AlmclientOraaWarnings 1 }
--- *****************************************************
--- LEAF for the pump1Alarms article
--- *****************************************************
pmora14Almpump1Alarms OBJECT IDENTIFIER ::= { pmora14AlmLineCrit 35 }
pmora14AlmPump1TecFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 1 TEC Fail :This OID indicates
that the TEC is in fail condition
on pump 1 <Help> This alarm indicates
if the TEC of the pump1 is in fail
condition <Condtype> PUMP1_TEC_FAIL
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmora14Almpump1Alarms 2 }
pmora14AlmPump1Shutdown OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 1 Laser Shutdown :This OID
indicates that the pump 1 is shutdown
<Help> This status indicates
if the pump1 is shutdown <Condtype>
PUMP1_SHUTDOWN <Probcause> informationalStatus(1000)
<Alarmtype> other(1) <Polarity>
(2)
"
::= { pmora14Almpump1Alarms 1 }
--- *****************************************************
--- LEAF for the pump2Alarms article
--- *****************************************************
pmora14Almpump2Alarms OBJECT IDENTIFIER ::= { pmora14AlmLineCrit 36 }
pmora14AlmPump2TecFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 2 TEC Fail :This OID indicates
that the TEC is in fail condition
on pump 2 <Help> This alarm indicates
if the TEC of the pump2 is in fail
condition <Condtype> PUMP2_TEC_FAIL
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmora14Almpump2Alarms 2 }
pmora14AlmPump2Shutdown OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 2 Laser Shutdown :This OID
indicates that the pump 2 is shutdown
<Help> This status indicates
if the pump2 is shutdown <Condtype>
PUMP2_SHUTDOWN <Probcause> informationalStatus(1000)
<Alarmtype> other(1) <Polarity>
(2)
"
::= { pmora14Almpump2Alarms 1 }
--- *****************************************************
--- LEAF for the fiberAlarms article
--- *****************************************************
pmora14AlmfiberAlarms OBJECT IDENTIFIER ::= { pmora14AlmLineUrg 72 }
pmora14AlmStartupHighBackReflection OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Startup High Back Reflection :This
OID indicates that a High Back
Reflection ratio is too high on
startup <Help> This alarm indicates
that a High Back Reflection ratio
is too high on startup <Condtype>
STARTUP_HIGH_BACK_REFLECTION <Probcause>
equipmentMalfunction (16) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmora14AlmfiberAlarms 9 }
pmora14AlmStartupLowSBand OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Startup Low S Band :This OID
indicates that the input power
over the S-Band is too low on startup
<Help> This alarm indicates that
the input power over the S-Band
is too low on startup <Condtype>
STARTUP_LOW_S_BAND <Probcause>
equipmentMalfunction (16) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmora14AlmfiberAlarms 8 }
pmora14AlmPartialAprSecurity OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Partial APR Security :This OID
indicates at least one APR security
switch has been disabled <Help>
This alarm indicates at least
one APR security switch has been
disabled <Condtype> PARTIAL_APR_SECURITY
<Probcause> other (1) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmora14AlmfiberAlarms 7 }
pmora14AlmOscFailed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Osc Failed :This OID indicates
that an OSC Loss of Frame is reported
by the linked HCS amplifier <Help>
This alarm indicates that an
OSC Loss of Frame is reported
by the linked HCS amplifier <Condtype>
OSC_FAILED <Probcause> equipmentMalfunction
(16) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmora14AlmfiberAlarms 6 }
pmora14AlmLineConnectorUnlocked OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Connector Unlocked :This
OID indicates the Fonrt panel
Line connector is not locked <Help>
This alarm indicates the Fonrt
panel Line connector is not locked
<Condtype> LINE_CONNECTOR_UNLOCKED
<Probcause> other (1) <Alarmtype>
operationalViolation (8) <Polarity>
(2)
"
::= { pmora14AlmfiberAlarms 5 }
pmora14AlmHighBackReflection OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
High Back Reflection :This OID
indicates that a High Back Reflection
ratio is too high <Help> This
alarm indicates that a High Back
Reflection ratio is too high <Condtype>
HIGH_BACK_REFLECTION <Probcause>
other (1) <Alarmtype> operationalViolation
(8) <Polarity> (2)
"
::= { pmora14AlmfiberAlarms 4 }
pmora14AlmCBandLossOfSignal OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
C Band Loss Of Signal :This OID
indicates that a Loss of Signal
is detected over the C-Band <Help>
This alarm indicates that a
Loss of Signal is detected over
the C-Band <Condtype> C_BAND_LOSS_OF_SIGNAL
<Probcause> lossOfSignal (30) <Alarmtype>
operationalViolation (8) <Polarity>
(2)
"
::= { pmora14AlmfiberAlarms 3 }
pmora14AlmLowSBand OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Low S Band :This OID indicates
that the input power over the S-Band
is too low <Help> This alarm
indicates that the input power
over the S-Band is too low <Condtype>
LOW_S_BAND <Probcause> other (1)
<Alarmtype> operationalViolation
(8) <Polarity> (2)
"
::= { pmora14AlmfiberAlarms 2 }
pmora14AlmSBandLossOfSignal OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
S Band Loss Of Signal :This OID
indicates that a Loss of Signal
is detected over the S-Band <Help>
This alarm indicates that a
Loss of Signal is detected over
the S-Band <Condtype> S_BAND_LOSS_OF_SIGNAL
<Probcause> lossOfSignal (30) <Alarmtype>
operationalViolation (8) <Polarity>
(2)
"
::= { pmora14AlmfiberAlarms 1 }
--- *****************************************************
--- LEAF for the moduleAlarms article
--- *****************************************************
pmora14AlmmoduleAlarms OBJECT IDENTIFIER ::= { pmora14AlmOtherUrg 74 }
pmora14AlmModuleTempHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Temperature High Alarm
:This OID indicates that the PM
temperature is higher than the
alarm threshold <Help> This
alarm indicates if the module
temperature is higher than the
alarm threshold <Condtype> MODULE_TEMP_HIGH_ALARM
<Probcause> temperatureUnacceptable
(51) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmora14AlmmoduleAlarms 2 }
pmora14AlmModuleTempLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Temperature Low Alarm :This
OID indicates that the PM temperature
if lower than the alarm threshold
<Help> This alarm indicates if
the module temperature is lower
than the alarm threshold <Condtype>
MODULE_TEMP_LOW_ALARM <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmora14AlmmoduleAlarms 1 }
--- *****************************************************
--- LEAF for the moduleWarnings article
--- *****************************************************
pmora14AlmmoduleWarnings OBJECT IDENTIFIER ::= { pmora14AlmOtherNurg 75 }
pmora14AlmModuleTempHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Temperature High Warning
:This OID indicates that the PM
temperature if higher than the
Warning threshold <Help> This
alarm indicates if the module temperature
is higher than the warning threshold
<Condtype> MODULE_TEMP_HIGH_WARNING
<Probcause> temperatureUnacceptable
(51) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmora14AlmmoduleWarnings 2 }
pmora14AlmModuleTempLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Temperature Low Warning
:This OID indicates that the PM
temperature if lower than the Warning
threshold <Help> This alarm indicates
if the module temperature is lower
than the warning threshold <Condtype>
MODULE_TEMP_LOW_WARNING <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmora14AlmmoduleWarnings 1 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONTROLS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the synth0 article
--- *****************************************************
pmora14Ctrlsynth0 OBJECT IDENTIFIER ::= { pmora14CtrlOther 0 }
pmora14CtrlConfClear OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Clear Configuration Tables :This
bit clears the configuration tables
from configuration in the flash.
<Help> This control restores
the default configuration of the
module
"
::= { pmora14Ctrlsynth0 13 }
pmora14CtrlConfFlash OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Write Configuration Tables :This
bit saves the current configuration
of the module as configuration
in the flash. <Help> This control
saves the customer configuration
on the module
"
::= { pmora14Ctrlsynth0 9 }
pmora14CtrlConfLoad OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Load Configuration Tables :When
set this enables loading from flash
configuration1 into the module.
"
::= { pmora14Ctrlsynth0 1 }
--- *****************************************************
--- LEAF for the swMgnt article
--- *****************************************************
pmora14CtrlswMgnt OBJECT IDENTIFIER ::= { pmora14CtrlOther 5 }
pmora14CtrlWarmReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
PM Warm Reset :This OID, when
set, causes a warm reset of the
Software. This reset is not traffic
affecting, and the configuration
of the Sofwtare remains unchanged.
<Help> This control initiates
a warm reset of the module.
"
::= { pmora14CtrlswMgnt 3 }
pmora14CtrlColdReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
PM Cold Reset :This OID, when
set, causes a cold reset of the
Software. This reset is traffic
affecting, and the configuration
of Software is reloaded on start-up.
<Help> This control initiates
a cold reset of the module.
"
::= { pmora14CtrlswMgnt 2 }
--- *****************************************************
--- LEAF for the aprMode article
--- *****************************************************
pmora14CtrlaprMode OBJECT-TYPE
SYNTAX Pmora14AprMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
APR Mode :This OID selects the
APR Mode <Help> This control
initiates the APR Mode
"
::= { pmora14CtrlOther 16 }
--- *****************************************************
--- LEAF for the ledTest article
--- *****************************************************
pmora14CtrlledTest OBJECT IDENTIFIER ::= { pmora14CtrlOther 73 }
pmora14CtrlLedOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Leds Off :This OID switches off
all the Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to OFF
"
::= { pmora14CtrlledTest 3 }
pmora14CtrlRedLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Red Leds Test :This OID switches
on all the red Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to red
"
::= { pmora14CtrlledTest 2 }
pmora14CtrlGreenLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Green Leds Test :This OID switches
on all the green Leds as a test
feature. <Help> This control
initiates a test leds turning
all the LEDs to green
"
::= { pmora14CtrlledTest 1 }
--- *****************************************************
--- LEAF for the maintMode article
--- *****************************************************
pmora14CtrlmaintMode OBJECT IDENTIFIER ::= { pmora14CtrlOther 74 }
pmora14CtrlMaintenance OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
PM Maintenance Mode :This OID
sets the PM in maintenance mode
<Help> This control enables the
maintenance mode of the module
"
::= { pmora14CtrlmaintMode 1 }
--- *****************************************************
--- LEAF for the aprManualRestart article
--- *****************************************************
pmora14CtrlaprManualRestart OBJECT IDENTIFIER ::= { pmora14CtrlLine 75 }
pmora14CtrlAprManualRestart OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
APR Manual Restart :This OID initiates
the Restart mechanism to retrieve
from the APR state.<Help> This
control initiates the Restart
mechanism to retrieve from the
APR state.
"
::= { pmora14CtrlaprManualRestart 1 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- COUNTERS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
pmora14CntCountersReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Counters Reset:This OID resets and restarts all the counters"
::= { pmora14counters 259 }
pmora14CntCountersStop OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Counters stop:This OID stops all the counters"
::= { pmora14counters 260 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- MEASURES
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the pump1CurrentMeas article
--- *****************************************************
pmora14Mesrpump1CurrentMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 1 Laser Current :This OID
gives the Pump1 laser current (Current
=AV/10) (Unit = mA) <Help> This
measure gives the Pump1 Laser current
"
::= { pmora14MesrLine 64 }
--- *****************************************************
--- LEAF for the pump1PowerMeas article
--- *****************************************************
pmora14Mesrpump1PowerMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 1 Tx Power :This OID gives
the Pump1 power value (Power =AV/20)
(Unit = mW) <Help> This measure
gives the Pump1 Power value
"
::= { pmora14MesrLine 65 }
--- *****************************************************
--- LEAF for the pump1TempMeas article
--- *****************************************************
pmora14Mesrpump1TempMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 1 Temperature :This OID gives
the Pump1 TEC temperature (Temperature
=AV/256) (Unit = C)<Help> This
measure gives the Pump1 TEC temperature
"
::= { pmora14MesrLine 66 }
--- *****************************************************
--- LEAF for the pump1TecCurrentMeas article
--- *****************************************************
pmora14Mesrpump1TecCurrentMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 1 TEC Current :This OID gives
the Pump1 TEC current (Current
=AV/10) (Unit = mA) <Help> This
measure gives the Pump1 TEC current
"
::= { pmora14MesrLine 67 }
--- *****************************************************
--- LEAF for the pump2CurrentMeas article
--- *****************************************************
pmora14Mesrpump2CurrentMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 2 Laser Current :This OID
gives the Pump2 laser current (Current
=AV/10) (Unit = mA) <Help> This
measure gives the Pump2 Laser current
"
::= { pmora14MesrLine 68 }
--- *****************************************************
--- LEAF for the pump2PowerMeas article
--- *****************************************************
pmora14Mesrpump2PowerMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 2 Tx Power :This OID gives
the Pump2 power value (Power =AV/20)
(Unit = mW) <Help> This measure
gives the Pump2 Power value
"
::= { pmora14MesrLine 69 }
--- *****************************************************
--- LEAF for the pump2TempMeas article
--- *****************************************************
pmora14Mesrpump2TempMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 2 Temperature :This OID gives
the Pump2 TEC temperature (Temperature
=AV/256) (Unit = C) <Help> This
measure gives the Pump2 TEC temperature
"
::= { pmora14MesrLine 70 }
--- *****************************************************
--- LEAF for the pump2TecCurrentMeas article
--- *****************************************************
pmora14Mesrpump2TecCurrentMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pump 2 TEC Current :This OID gives
the Pump2 TEC current (Current
=AV/10) (Unit = mA) <Help> This
measure gives the Pump2 TEC current
"
::= { pmora14MesrLine 71 }
--- *****************************************************
--- LEAF for the totalPumpsPower article
--- *****************************************************
pmora14MesrtotalPumpsPower OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Total Pumps Power :This OID indicates
the total pumps power (Power =
AV/20) (Unit = mW) <Help> This
measure indicates the total pump
power
"
::= { pmora14MesrLine 72 }
--- *****************************************************
--- LEAF for the inputCBandPower article
--- *****************************************************
pmora14MesrinputCBandPower OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Input C Band Power :This OID indicates
the input power over the C-Band
(Power =(AV-32768)*0,005) (Unit
= dBm) <Help> This measure indicates
the input power over the C-Band
"
::= { pmora14MesrLine 73 }
--- *****************************************************
--- LEAF for the sBandPower article
--- *****************************************************
pmora14MesrsBandPower OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
S Band Power :This OID indicates
the input power over the S-band
(Power =(AV-32768)*0,005) (Unit
= dBm) <Help> This measure indicates
the input power over the S-Band
"
::= { pmora14MesrLine 74 }
--- *****************************************************
--- LEAF for the backReflectionPumpPower article
--- *****************************************************
pmora14MesrbackReflectionPumpPower OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Back Reflection Pump Power :This
OID indicates the Back Reflection
Pump power (Power =(AV-32768)*0,005)
(Unit = dBm) <Help> This measure
indicates the Back Reflection Pump
power
"
::= { pmora14MesrLine 75 }
--- *****************************************************
--- LEAF for the backReflectionPumpRatio article
--- *****************************************************
pmora14MesrbackReflectionPumpRatio OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Back Reflection Pump Ratio :This
OID indicates the Back Relfection
Pump ration (Power =(AV-32768)*0,005)
(Unit = dB) <Help> This measure
indicates the Back Reflection Pump
ratio
"
::= { pmora14MesrLine 76 }
--- *****************************************************
--- LEAF for the pmTempMeas article
--- *****************************************************
pmora14MesrpmTempMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Temperature :This OID gives
the temperature of the PM (Temperature
=AV/256) (Unit = C)<Help> This
measure gives the temperature of
the module
"
::= { pmora14MesrOther 80 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONFIG
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the table Group noValue
--- *****************************************************
pmora14CfgNoValue OBJECT IDENTIFIER ::= { pmora14Config 1 }
--- *****************************************************
--- LEAF for the table 2191
--- *****************************************************
pmora14tablelineStartup OBJECT IDENTIFIER ::= { pmora14CfgNoValue 1 }
pmora14CfgoraModuleCtrl OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on the module
:This OID configures the default
initialisation settings of the
Raman module
"
::= { pmora14tablelineStartup 2 }
pmora14CfgautoRestartDelay OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on autorestart
delay :This OID configures the
default period on the autorestart
"
::= { pmora14tablelineStartup 3 }
pmora14CfgramanGain OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on the Raman
Gain :This OID configures the
default gain on the Raman module
"
::= { pmora14tablelineStartup 4 }
pmora14CfgramanMode OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Raman mode
:This OID configures the default
Raman mode
"
::= { pmora14tablelineStartup 5 }
pmora14CfgtiltValue OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on the tilt value
:This OID configures the default
tilt on the line amplifier.
"
::= { pmora14tablelineStartup 6 }
pmora14CfghighBackreflectionThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on the backreflection
threshold :This OID configures
the default threshold on the backreflection
"
::= { pmora14tablelineStartup 7 }
pmora14CfgsBandThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on the S band
threshold :This OID configures
the default threshold on the S
band
"
::= { pmora14tablelineStartup 8 }
pmora14Cfgpump1ManualPower OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on the pump power
:This OID configures the default
value on the power
"
::= { pmora14tablelineStartup 9 }
pmora14Cfgpump2ManualPower OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on the pump power
:This OID configures the default
value on the power
"
::= { pmora14tablelineStartup 10 }
--- *****************************************************
--- LEAF for the table Group labels
--- *****************************************************
pmora14CfgLabels OBJECT IDENTIFIER ::= { pmora14Config 2 }
--- *****************************************************
--- LEAF for the table NO_VALUE
--- *****************************************************
pmora14CfgLabelclientTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pmora14CfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pmora14CfgLabels 1 }
pmora14CfgLabelclientEntry OBJECT-TYPE
SYNTAX Pmora14CfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pmora14CfgLabelclientIndex }
::= { pmora14CfgLabelclientTable 1 }
Pmora14CfgLabelclientEntry ::=
SEQUENCE {
pmora14CfgLabelclientIndex
INTEGER,
pmora14CfgLabelclientPortn
DisplayString
}
pmora14CfgLabelclientIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelclient
table
"
::= { pmora14CfgLabelclientEntry 1 }
pmora14CfgLabelclientPortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the Ports :These registers
configures the default initialisation
settings of the labels of the ports.
"
::= { pmora14CfgLabelclientEntry 3 }
--- *****************************************************
--- LEAF for the table NO_VALUE
--- *****************************************************
pmora14CfgLabellineTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pmora14CfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pmora14CfgLabels 2 }
pmora14CfgLabellineEntry OBJECT-TYPE
SYNTAX Pmora14CfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pmora14CfgLabellineIndex }
::= { pmora14CfgLabellineTable 1 }
Pmora14CfgLabellineEntry ::=
SEQUENCE {
pmora14CfgLabellineIndex
INTEGER,
pmora14CfgLabellinePortn
DisplayString
}
pmora14CfgLabellineIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelline
table
"
::= { pmora14CfgLabellineEntry 1 }
pmora14CfgLabellinePortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the lines :These registers
configures the default initialisation
settings of the labels of the lines.
"
::= { pmora14CfgLabellineEntry 3 }
pmora14CfgWriteConfiguration OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Write configuration to module:This OID
writes the complete configuration to the module"
::= { pmora14Config 257 }
--- *****************************************************
--- TRAP OBJECTS
--- *****************************************************
pmora14trapBoardNumber OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last module which generates a trap"
::= { pmora14traps 4 }
--- *****************************************************
--- GLOBAL TRAPS
--- *****************************************************
pmora14LineTrapCritGoesOn NOTIFICATION-TYPE
OBJECTS {pmora14AlmLineFail, pmora14AlmLineHwFail, pmora14trapBoardNumber}
STATUS current
--&FILTNAME "PMORA14 Line Fail ON"
--&ACTIONS { log, critical }
--&MATCH { pmora14AlmLineFail "on", pmora14AlmLineHwFail "*", pmora14trapBoardNumber "$3"}
--&MESG "Critical Alarm appears on PMORA14 in slot $3 ($A)"
--&FILTNAME "PMORA14 Line HW Fail ON (Hidden)"
--&ACTIONS { info }
--&MATCH { pmora14AlmLineFail "*", pmora14AlmLineHwFail "on", pmora14trapBoardNumber "$3"}
--&MESG "Critical Alarm appears on PMORA14 in slot $3 ($A)"
DESCRIPTION "Critical Line default is activated"
::= { pmora14traps 34 }
pmora14LineTrapCritGoesOff NOTIFICATION-TYPE
OBJECTS {pmora14AlmLineFail, pmora14AlmLineHwFail, pmora14trapBoardNumber}
STATUS current
--&FILTNAME "PMORA14 Line Fail OFF"
--&ACTIONS { log, normal }
--&CLEARS {"PMORA14 Line Fail ON"}
--&MATCH { pmora14AlmLineFail "on", pmora14AlmLineHwFail "*", pmora14trapBoardNumber "$3"}
--&MESG "Critical Alarm disappears on PMORA14 in slot $3 ($A)"
--&FILTNAME "PMORA14 Line HW Fail OFF (Hidden)"
--&ACTIONS { info }
--&MATCH { pmora14AlmLineFail "*", pmora14AlmLineHwFail "on", pmora14trapBoardNumber "$3"}
--&MESG "Critical Alarm disappears on PMORA14 in slot $3 ($A)"
DESCRIPTION "Critical Line default disappeared"
::= { pmora14traps 35 }
--- *****************************************************
--- PORTS TRAPS
--- *****************************************************
--- *****************************************************
--- HW TRAPS
--- *****************************************************
pmora14PowerTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmora14AlmDefFuseB, pmora14AlmDefFuseA , pmora14trapBoardNumber}
STATUS current
--&FILTNAME "PMORA Fuse A Fail ON"
--&ACTIONS { log, major }
--&MATCH { pmora14AlmDefFuseB "*", pmora14AlmDefFuseA "on", pmora14trapBoardNumber "$3"}
--&MESG "Power Input A Fail on PMORA in Slot $3 ($A)"
--&FILTNAME "PMORA Fuse B Fail ON"
--&ACTIONS { log, major }
--&MATCH { pmora14AlmDefFuseB "on", pmora14AlmDefFuseA "*", pmora14trapBoardNumber "$3"}
--&MESG "Power Input B Fail on PMORA in Slot $3 ($A)"
DESCRIPTION "Urgent power supply default is activated"
::= { pmora14traps 50 }
pmora14PowerTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmora14AlmDefFuseB, pmora14AlmDefFuseA , pmora14trapBoardNumber}
STATUS current
--&FILTNAME "PMORA Fuse A&B Fail OFF"
--&ACTIONS { log, normal}
--&CLEARS { "PMORA Fuse A Fail ON", "PMORA Fuse B Fail ON" }
--&MATCH { pmora14AlmDefFuseB "on", pmora14AlmDefFuseA "on", pmora14trapBoardNumber "$3"}
--&MESG "Power Inputs A and B Present on PMORA in Slot $3 ($A)"
DESCRIPTION "Urgent power supply default disappeared"
::= { pmora14traps 51 }
END