2011 lines
51 KiB
Plaintext
2011 lines
51 KiB
Plaintext
-- *****************************************************************
|
||
-- EKINOPS-pmora14.TXT: MIB
|
||
--
|
||
--MIB Part Number:3MI00216AAAB
|
||
--MIB Version:01
|
||
--
|
||
-- Copyright (c) 2016 by Ekinops
|
||
-- All rights reserved.
|
||
--
|
||
-- *****************************************************************
|
||
|
||
EKINOPS-Pmora14-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
ekinops,
|
||
EkiState,
|
||
EkiOnOff,
|
||
EkiMode,
|
||
EkiProtocol,
|
||
EkiApiState,
|
||
EkiSynchroMode,
|
||
EkiMeasureType
|
||
FROM EKINOPS-MIB
|
||
MODULE-IDENTITY,
|
||
OBJECT-TYPE,
|
||
NOTIFICATION-TYPE,
|
||
Unsigned32,
|
||
Integer32,
|
||
Counter32,
|
||
IpAddress
|
||
FROM SNMPv2-SMI
|
||
TEXTUAL-CONVENTION,
|
||
DisplayString
|
||
FROM SNMPv2-TC;
|
||
|
||
modulepmora14 MODULE-IDENTITY
|
||
LAST-UPDATED "201605230000Z"
|
||
ORGANIZATION "Ekinops"
|
||
CONTACT-INFO
|
||
"Ekinops
|
||
|
||
3, rue Blaise Pascal
|
||
F-22300 Lannion / FRANCE
|
||
|
||
Tel : +33 (0)2 96 05 00 30
|
||
Fax : +33 (0)2 96 48 62 39
|
||
|
||
E-mail: support@ekinops.net"
|
||
DESCRIPTION
|
||
"Creation"
|
||
|
||
REVISION "201508310000Z"
|
||
DESCRIPTION
|
||
"Creation"
|
||
REVISION "201605230000Z"
|
||
DESCRIPTION
|
||
"New AlarmType – synthesisAlarm (12)"
|
||
::= { ekinops 72 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF LEVEL 2
|
||
--- *****************************************************
|
||
|
||
|
||
pmora14alarms OBJECT IDENTIFIER ::= { modulepmora14 2 }
|
||
pmora14AlmOther OBJECT IDENTIFIER ::= { pmora14alarms 1 }
|
||
pmora14AlmOtherNurg OBJECT IDENTIFIER ::= { pmora14AlmOther 1 }
|
||
pmora14AlmOtherUrg OBJECT IDENTIFIER ::= { pmora14AlmOther 2 }
|
||
pmora14AlmOtherCrit OBJECT IDENTIFIER ::= { pmora14AlmOther 3 }
|
||
|
||
pmora14AlmClient OBJECT IDENTIFIER ::= { pmora14alarms 2 }
|
||
pmora14AlmClientNurg OBJECT IDENTIFIER ::= { pmora14AlmClient 1 }
|
||
pmora14AlmClientUrg OBJECT IDENTIFIER ::= { pmora14AlmClient 2 }
|
||
pmora14AlmClientCrit OBJECT IDENTIFIER ::= { pmora14AlmClient 3 }
|
||
|
||
pmora14AlmLine OBJECT IDENTIFIER ::= { pmora14alarms 3 }
|
||
pmora14AlmLineNurg OBJECT IDENTIFIER ::= { pmora14AlmLine 1 }
|
||
pmora14AlmLineUrg OBJECT IDENTIFIER ::= { pmora14AlmLine 2 }
|
||
pmora14AlmLineCrit OBJECT IDENTIFIER ::= { pmora14AlmLine 3 }
|
||
|
||
pmora14measures OBJECT IDENTIFIER ::= { modulepmora14 3 }
|
||
pmora14MesrOther OBJECT IDENTIFIER ::= { pmora14measures 1 }
|
||
pmora14MesrClient OBJECT IDENTIFIER ::= { pmora14measures 2 }
|
||
pmora14MesrLine OBJECT IDENTIFIER ::= { pmora14measures 3 }
|
||
|
||
pmora14counters OBJECT IDENTIFIER ::= { modulepmora14 4 }
|
||
pmora14CntOther OBJECT IDENTIFIER ::= { pmora14counters 1 }
|
||
pmora14CntClient OBJECT IDENTIFIER ::= { pmora14counters 2 }
|
||
pmora14CntLine OBJECT IDENTIFIER ::= { pmora14counters 3 }
|
||
|
||
pmora14controlsWrite OBJECT IDENTIFIER ::= { modulepmora14 6 }
|
||
pmora14CtrlOther OBJECT IDENTIFIER ::= { pmora14controlsWrite 1 }
|
||
pmora14CtrlClient OBJECT IDENTIFIER ::= { pmora14controlsWrite 2 }
|
||
pmora14CtrlLine OBJECT IDENTIFIER ::= { pmora14controlsWrite 3 }
|
||
|
||
pmora14ri OBJECT IDENTIFIER ::= { modulepmora14 7 }
|
||
pmora14riTable OBJECT IDENTIFIER ::= { pmora14ri 1 }
|
||
|
||
pmora14Config OBJECT IDENTIFIER ::= { modulepmora14 9 }
|
||
|
||
pmora14traps OBJECT IDENTIFIER ::= { modulepmora14 10 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- TEXTUAL-CONVENTION
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
Pmora14PumpsMode ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Different modes on the Raman Module"
|
||
SYNTAX INTEGER {
|
||
ora14maxpowermode(0),
|
||
ora14gaincontrolmode(1),
|
||
ora14manualcontrolmode(2)
|
||
|
||
}
|
||
|
||
|
||
|
||
Pmora14AprMode ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Different modes on APR"
|
||
SYNTAX INTEGER {
|
||
ora14aproffmode(0),
|
||
ora14aproscmode(1),
|
||
ora14aprbrratiomode(2)
|
||
ora14aprsbandmode(3)
|
||
ora14aprfullmode(4)
|
||
|
||
}
|
||
|
||
|
||
|
||
Pmora14LineFiberTypeMode ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Different modes on APR"
|
||
SYNTAX INTEGER {
|
||
ora14g652mode(0),
|
||
ora14g655leafmode(1),
|
||
ora14g655truewavemode(2)
|
||
ora14g654mode(3)
|
||
ora14g653mode(4)
|
||
|
||
}
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- REMOTE INVENTORY
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
pmora14RinvReloadInventory OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reload the inventory: This OID triggers an
|
||
inventory reload."
|
||
::= { pmora14ri 2 }
|
||
|
||
pmora14RinvHwPlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"HW platform description: This OID contains the
|
||
description of the Hardware platform."
|
||
::= { pmora14ri 3 }
|
||
|
||
pmora14RinvModulePlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Module platform description: This OID contains the
|
||
description of the Module."
|
||
::= { pmora14ri 4 }
|
||
|
||
pmora14RinvSwPlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SW platform description: This OID contains the
|
||
description of the Software platform."
|
||
::= { pmora14ri 5 }
|
||
|
||
pmora14RinvGwPlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"GW platform description: This OID contains the
|
||
description of the gateware platform."
|
||
::= { pmora14ri 6 }
|
||
|
||
|
||
|
||
|
||
pmora14RinvLineTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmora14RinvLineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of the Lines on the selected module"
|
||
::= { pmora14riTable 2 }
|
||
|
||
pmora14RinvLineEntry OBJECT-TYPE
|
||
SYNTAX Pmora14RinvLineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Row definition for the Line table"
|
||
INDEX { pmora14RinvLineIndex }
|
||
::= { pmora14RinvLineTable 1 }
|
||
|
||
|
||
|
||
Pmora14RinvLineEntry::=
|
||
SEQUENCE {
|
||
pmora14RinvLineIndex
|
||
Integer32,
|
||
pmora14RinvportLine
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmora14RinvLineIndex OBJECT-TYPE
|
||
SYNTAX Integer32(1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for Line table"
|
||
::= { pmora14RinvLineEntry 1 }
|
||
|
||
|
||
pmora14RinvportLine OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Inventory for the Line: This OID contains the inventory for the Line"
|
||
::= { pmora14RinvLineEntry 2 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- ALARMS
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm0 article
|
||
--- *****************************************************
|
||
pmora14AlmsynthAlm0 OBJECT IDENTIFIER ::= { pmora14AlmOtherCrit 0 }
|
||
|
||
|
||
|
||
|
||
pmora14AlmDefFuseB OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Fuse B Fail :This OID indicates
|
||
that the fuse of the power input
|
||
B is in fail condition <Help>
|
||
Status of the Fuse B <Condtype>
|
||
DEF_FUSE_B <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmsynthAlm0 16 }
|
||
|
||
|
||
|
||
pmora14AlmDefFuseA OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Fuse A Fail :This OID indicates
|
||
that the fuse of the power input
|
||
A is in fail condition <Help>
|
||
Status of the Fuse A <Condtype>
|
||
DEF_FUSE_A <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmsynthAlm0 15 }
|
||
|
||
|
||
|
||
pmora14AlmInitNotCompl OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Raman Module Not Initialized :This
|
||
OID indicates that the initialisation
|
||
of the Raman module is not completed
|
||
<Help> This status indicates
|
||
if the Raman has been correctly
|
||
initialized <Condtype> INIT_NOT_COMPL
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmsynthAlm0 10 }
|
||
|
||
|
||
|
||
pmora14AlmModGlobFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Failure :This OID is set
|
||
on detection of a failure originating
|
||
from the PM <Help> This alarm
|
||
<Condtype> MOD_GLOB_FAIL <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmora14AlmsynthAlm0 9 }
|
||
|
||
|
||
|
||
pmora14AlmAprOn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Automatic Power Reduction :This
|
||
OID indicates that the APR algorithm
|
||
has been operated and the output
|
||
of the lasers are shutdown <Help>
|
||
The APR algorithm has been completed
|
||
<Condtype> APR_ON <Probcause>
|
||
other (1) <Alarmtype> other (1)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmora14AlmsynthAlm0 2 }
|
||
|
||
|
||
|
||
pmora14AlmMaintenanceMode OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Maintenance Mode :This OID indicates
|
||
that the PM is in maintenance mode
|
||
<Help> This status indiates
|
||
if the module is currently in
|
||
maintenance mode <Condtype> MAINTENANCE_MODE
|
||
<Probcause> other (1) <Alarmtype>
|
||
other (1) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmsynthAlm0 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm2 article
|
||
--- *****************************************************
|
||
pmora14AlmsynthAlm2 OBJECT IDENTIFIER ::= { pmora14AlmOtherNurg 2 }
|
||
|
||
|
||
|
||
|
||
pmora14AlmConfTableLoad OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Configuration Load :This OID
|
||
is at 1 during the loading of
|
||
configuration tables in the modules
|
||
RAM. <Condtype> CONF_TABLE_LOAD
|
||
<Probcause> other (1) <Alarmtype>
|
||
other (1) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmsynthAlm2 3 }
|
||
|
||
|
||
|
||
pmora14AlmInvUpload OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Inventory Upload :This OID is
|
||
at 1 during the uploading of PM
|
||
inventory information. <Condtype>
|
||
INV_UPLOAD <Probcause> other (1)
|
||
<Alarmtype> other (1) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmora14AlmsynthAlm2 2 }
|
||
|
||
|
||
|
||
pmora14AlmConfTableSave OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Configuration Save :This OID
|
||
is at 1 during the saving of a
|
||
new configuration table in the
|
||
module Flash memory. <Condtype>
|
||
CONF_TABLE_SAVE <Probcause> other
|
||
(1) <Alarmtype> other (1) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmora14AlmsynthAlm2 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm7 article
|
||
--- *****************************************************
|
||
pmora14AlmsynthAlm7 OBJECT IDENTIFIER ::= { pmora14AlmLineUrg 7 }
|
||
|
||
|
||
|
||
|
||
pmora14AlmLineFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Port Failure :This OID indicates
|
||
a failure on the line port <Help>
|
||
This alarm indicates a failure
|
||
on the Line port <Condtype> LINE_FAIL
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmsynthAlm7 12 }
|
||
|
||
|
||
|
||
pmora14AlmPumpsTxOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pumps Laser Shutdown :This OID
|
||
indicates the power of the pumps
|
||
are both on <Help> This status
|
||
indicates if the pumps lasers are
|
||
both OFF <Condtype> PUMPS_TX_OFF
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
other (1) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmsynthAlm7 5 }
|
||
|
||
|
||
|
||
pmora14AlmLineHwFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Port HW Failure :This OID
|
||
indicates a failure on line port,
|
||
most probably caused by a HW issue
|
||
<Help> This alarm indicates a failure
|
||
on the HW Line port <Condtype>
|
||
LINE_HW_FAIL <Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmsynthAlm7 4 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientOraAlarms1 article
|
||
--- *****************************************************
|
||
pmora14AlmclientOraAlarms1 OBJECT IDENTIFIER ::= { pmora14AlmLineUrg 32 }
|
||
|
||
|
||
|
||
|
||
pmora14AlmPump2TecAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 2 TEC Alarm :This OID indicates
|
||
a transmit laser fail on pump 2
|
||
<Help> This alarm indicates if
|
||
the laser of the pump2 is in fail
|
||
condition <Condtype> PUMP2_TEC_ALARM
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmclientOraAlarms1 4 }
|
||
|
||
|
||
|
||
pmora14AlmPump1TecAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 1 TEC Alarm :This OID indicates
|
||
a transmit laser fail on pump 1
|
||
<Help> This alarm indicates if
|
||
the laser of the pump1 is in fail
|
||
condition <Condtype> PUMP1_TEC_ALARM
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmclientOraAlarms1 3 }
|
||
|
||
|
||
|
||
pmora14AlmPump2CurrentHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 2 Current High Alarm :This
|
||
OID indicates the Pump2 current
|
||
is higher than the alarm threshold
|
||
<Help> This alarm indicates if
|
||
the pump2 current is higher than
|
||
the alarm threshold <Condtype>
|
||
PUMP2_CURRENT_HIGH_ALARM <Probcause>
|
||
performanceDegraded (35) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmclientOraAlarms1 2 }
|
||
|
||
|
||
|
||
pmora14AlmPump1CurrentHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 1 Current High Alarm :This
|
||
OID indicates the Pump1 current
|
||
is higher than the alarm threshold
|
||
<Help> This alarm indicates if
|
||
the pump1 current is higher than
|
||
the alarm threshold <Condtype>
|
||
PUMP1_CURRENT_HIGH_ALARM <Probcause>
|
||
performanceDegraded (35) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmclientOraAlarms1 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientOraaWarnings article
|
||
--- *****************************************************
|
||
pmora14AlmclientOraaWarnings OBJECT IDENTIFIER ::= { pmora14AlmLineNurg 33 }
|
||
|
||
|
||
|
||
|
||
pmora14AlmPump2TecWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 2 TEC Warning :This OID indicates
|
||
a transmit laser fail on pump 2
|
||
<Help> This alarm indicates if
|
||
the laser of the pump2 is in fail
|
||
condition <Condtype> PUMP2_TEC_WARNING
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmclientOraaWarnings 4 }
|
||
|
||
|
||
|
||
pmora14AlmPump1TecWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 1 TEC Warning :This OID indicates
|
||
a transmit laser fail on pump 1
|
||
<Help> This alarm indicates if
|
||
the laser of the pump1 is in fail
|
||
condition <Condtype> PUMP1_TEC_WARNING
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmclientOraaWarnings 3 }
|
||
|
||
|
||
|
||
pmora14AlmPump2CurrentHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 2 Current High Warning :This
|
||
OID indicates the Pump2 current
|
||
is higher than the warning threshold
|
||
<Help> This alarm indicates if
|
||
the pump2 current is higher than
|
||
the warning threshold <Condtype>
|
||
PUMP2_CURRENT_HIGH_WARNING <Probcause>
|
||
performanceDegraded (35) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmclientOraaWarnings 2 }
|
||
|
||
|
||
|
||
pmora14AlmPump1CurrentHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 1 Current High Warning :This
|
||
OID indicates the Pump1 current
|
||
is higher than the warning threshold
|
||
<Help> This alarm indicates if
|
||
the pump1 current is higher than
|
||
the warning threshold <Condtype>
|
||
PUMP1_CURRENT_HIGH_WARNING <Probcause>
|
||
performanceDegraded (35) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmclientOraaWarnings 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the pump1Alarms article
|
||
--- *****************************************************
|
||
pmora14Almpump1Alarms OBJECT IDENTIFIER ::= { pmora14AlmLineCrit 35 }
|
||
|
||
|
||
|
||
|
||
pmora14AlmPump1TecFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 1 TEC Fail :This OID indicates
|
||
that the TEC is in fail condition
|
||
on pump 1 <Help> This alarm indicates
|
||
if the TEC of the pump1 is in fail
|
||
condition <Condtype> PUMP1_TEC_FAIL
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmora14Almpump1Alarms 2 }
|
||
|
||
|
||
|
||
pmora14AlmPump1Shutdown OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 1 Laser Shutdown :This OID
|
||
indicates that the pump 1 is shutdown
|
||
<Help> This status indicates
|
||
if the pump1 is shutdown <Condtype>
|
||
PUMP1_SHUTDOWN <Probcause> informationalStatus(1000)
|
||
<Alarmtype> other(1) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmora14Almpump1Alarms 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the pump2Alarms article
|
||
--- *****************************************************
|
||
pmora14Almpump2Alarms OBJECT IDENTIFIER ::= { pmora14AlmLineCrit 36 }
|
||
|
||
|
||
|
||
|
||
pmora14AlmPump2TecFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 2 TEC Fail :This OID indicates
|
||
that the TEC is in fail condition
|
||
on pump 2 <Help> This alarm indicates
|
||
if the TEC of the pump2 is in fail
|
||
condition <Condtype> PUMP2_TEC_FAIL
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmora14Almpump2Alarms 2 }
|
||
|
||
|
||
|
||
pmora14AlmPump2Shutdown OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 2 Laser Shutdown :This OID
|
||
indicates that the pump 2 is shutdown
|
||
<Help> This status indicates
|
||
if the pump2 is shutdown <Condtype>
|
||
PUMP2_SHUTDOWN <Probcause> informationalStatus(1000)
|
||
<Alarmtype> other(1) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmora14Almpump2Alarms 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the fiberAlarms article
|
||
--- *****************************************************
|
||
pmora14AlmfiberAlarms OBJECT IDENTIFIER ::= { pmora14AlmLineUrg 72 }
|
||
|
||
|
||
|
||
|
||
pmora14AlmStartupHighBackReflection OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Startup High Back Reflection :This
|
||
OID indicates that a High Back
|
||
Reflection ratio is too high on
|
||
startup <Help> This alarm indicates
|
||
that a High Back Reflection ratio
|
||
is too high on startup <Condtype>
|
||
STARTUP_HIGH_BACK_REFLECTION <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmfiberAlarms 9 }
|
||
|
||
|
||
|
||
pmora14AlmStartupLowSBand OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Startup Low S Band :This OID
|
||
indicates that the input power
|
||
over the S-Band is too low on startup
|
||
<Help> This alarm indicates that
|
||
the input power over the S-Band
|
||
is too low on startup <Condtype>
|
||
STARTUP_LOW_S_BAND <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmfiberAlarms 8 }
|
||
|
||
|
||
|
||
pmora14AlmPartialAprSecurity OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Partial APR Security :This OID
|
||
indicates at least one APR security
|
||
switch has been disabled <Help>
|
||
This alarm indicates at least
|
||
one APR security switch has been
|
||
disabled <Condtype> PARTIAL_APR_SECURITY
|
||
<Probcause> other (1) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmfiberAlarms 7 }
|
||
|
||
|
||
|
||
pmora14AlmOscFailed OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Osc Failed :This OID indicates
|
||
that an OSC Loss of Frame is reported
|
||
by the linked HCS amplifier <Help>
|
||
This alarm indicates that an
|
||
OSC Loss of Frame is reported
|
||
by the linked HCS amplifier <Condtype>
|
||
OSC_FAILED <Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmfiberAlarms 6 }
|
||
|
||
|
||
|
||
pmora14AlmLineConnectorUnlocked OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Connector Unlocked :This
|
||
OID indicates the Fonrt panel
|
||
Line connector is not locked <Help>
|
||
This alarm indicates the Fonrt
|
||
panel Line connector is not locked
|
||
<Condtype> LINE_CONNECTOR_UNLOCKED
|
||
<Probcause> other (1) <Alarmtype>
|
||
operationalViolation (8) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmora14AlmfiberAlarms 5 }
|
||
|
||
|
||
|
||
pmora14AlmHighBackReflection OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
High Back Reflection :This OID
|
||
indicates that a High Back Reflection
|
||
ratio is too high <Help> This
|
||
alarm indicates that a High Back
|
||
Reflection ratio is too high <Condtype>
|
||
HIGH_BACK_REFLECTION <Probcause>
|
||
other (1) <Alarmtype> operationalViolation
|
||
(8) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmfiberAlarms 4 }
|
||
|
||
|
||
|
||
pmora14AlmCBandLossOfSignal OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
C Band Loss Of Signal :This OID
|
||
indicates that a Loss of Signal
|
||
is detected over the C-Band <Help>
|
||
This alarm indicates that a
|
||
Loss of Signal is detected over
|
||
the C-Band <Condtype> C_BAND_LOSS_OF_SIGNAL
|
||
<Probcause> lossOfSignal (30) <Alarmtype>
|
||
operationalViolation (8) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmora14AlmfiberAlarms 3 }
|
||
|
||
|
||
|
||
pmora14AlmLowSBand OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Low S Band :This OID indicates
|
||
that the input power over the S-Band
|
||
is too low <Help> This alarm
|
||
indicates that the input power
|
||
over the S-Band is too low <Condtype>
|
||
LOW_S_BAND <Probcause> other (1)
|
||
<Alarmtype> operationalViolation
|
||
(8) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmfiberAlarms 2 }
|
||
|
||
|
||
|
||
pmora14AlmSBandLossOfSignal OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
S Band Loss Of Signal :This OID
|
||
indicates that a Loss of Signal
|
||
is detected over the S-Band <Help>
|
||
This alarm indicates that a
|
||
Loss of Signal is detected over
|
||
the S-Band <Condtype> S_BAND_LOSS_OF_SIGNAL
|
||
<Probcause> lossOfSignal (30) <Alarmtype>
|
||
operationalViolation (8) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmora14AlmfiberAlarms 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the moduleAlarms article
|
||
--- *****************************************************
|
||
pmora14AlmmoduleAlarms OBJECT IDENTIFIER ::= { pmora14AlmOtherUrg 74 }
|
||
|
||
|
||
|
||
|
||
pmora14AlmModuleTempHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Temperature High Alarm
|
||
:This OID indicates that the PM
|
||
temperature is higher than the
|
||
alarm threshold <Help> This
|
||
alarm indicates if the module
|
||
temperature is higher than the
|
||
alarm threshold <Condtype> MODULE_TEMP_HIGH_ALARM
|
||
<Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmmoduleAlarms 2 }
|
||
|
||
|
||
|
||
pmora14AlmModuleTempLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Temperature Low Alarm :This
|
||
OID indicates that the PM temperature
|
||
if lower than the alarm threshold
|
||
<Help> This alarm indicates if
|
||
the module temperature is lower
|
||
than the alarm threshold <Condtype>
|
||
MODULE_TEMP_LOW_ALARM <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmmoduleAlarms 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the moduleWarnings article
|
||
--- *****************************************************
|
||
pmora14AlmmoduleWarnings OBJECT IDENTIFIER ::= { pmora14AlmOtherNurg 75 }
|
||
|
||
|
||
|
||
|
||
pmora14AlmModuleTempHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Temperature High Warning
|
||
:This OID indicates that the PM
|
||
temperature if higher than the
|
||
Warning threshold <Help> This
|
||
alarm indicates if the module temperature
|
||
is higher than the warning threshold
|
||
<Condtype> MODULE_TEMP_HIGH_WARNING
|
||
<Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmmoduleWarnings 2 }
|
||
|
||
|
||
|
||
pmora14AlmModuleTempLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Temperature Low Warning
|
||
:This OID indicates that the PM
|
||
temperature if lower than the Warning
|
||
threshold <Help> This alarm indicates
|
||
if the module temperature is lower
|
||
than the warning threshold <Condtype>
|
||
MODULE_TEMP_LOW_WARNING <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmora14AlmmoduleWarnings 1 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- CONTROLS
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synth0 article
|
||
--- *****************************************************
|
||
pmora14Ctrlsynth0 OBJECT IDENTIFIER ::= { pmora14CtrlOther 0 }
|
||
|
||
|
||
|
||
|
||
pmora14CtrlConfClear OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Clear Configuration Tables :This
|
||
bit clears the configuration tables
|
||
from configuration in the flash.
|
||
<Help> This control restores
|
||
the default configuration of the
|
||
module
|
||
"
|
||
::= { pmora14Ctrlsynth0 13 }
|
||
|
||
|
||
|
||
pmora14CtrlConfFlash OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Write Configuration Tables :This
|
||
bit saves the current configuration
|
||
of the module as configuration
|
||
in the flash. <Help> This control
|
||
saves the customer configuration
|
||
on the module
|
||
"
|
||
::= { pmora14Ctrlsynth0 9 }
|
||
|
||
|
||
|
||
pmora14CtrlConfLoad OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Load Configuration Tables :When
|
||
set this enables loading from flash
|
||
configuration1 into the module.
|
||
"
|
||
::= { pmora14Ctrlsynth0 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the swMgnt article
|
||
--- *****************************************************
|
||
pmora14CtrlswMgnt OBJECT IDENTIFIER ::= { pmora14CtrlOther 5 }
|
||
|
||
|
||
|
||
|
||
pmora14CtrlWarmReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Warm Reset :This OID, when
|
||
set, causes a warm reset of the
|
||
Software. This reset is not traffic
|
||
affecting, and the configuration
|
||
of the Sofwtare remains unchanged.
|
||
<Help> This control initiates
|
||
a warm reset of the module.
|
||
"
|
||
::= { pmora14CtrlswMgnt 3 }
|
||
|
||
|
||
|
||
pmora14CtrlColdReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Cold Reset :This OID, when
|
||
set, causes a cold reset of the
|
||
Software. This reset is traffic
|
||
affecting, and the configuration
|
||
of Software is reloaded on start-up.
|
||
<Help> This control initiates
|
||
a cold reset of the module.
|
||
"
|
||
::= { pmora14CtrlswMgnt 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the aprMode article
|
||
--- *****************************************************
|
||
|
||
pmora14CtrlaprMode OBJECT-TYPE
|
||
SYNTAX Pmora14AprMode
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
APR Mode :This OID selects the
|
||
APR Mode <Help> This control
|
||
initiates the APR Mode
|
||
"
|
||
::= { pmora14CtrlOther 16 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the ledTest article
|
||
--- *****************************************************
|
||
pmora14CtrlledTest OBJECT IDENTIFIER ::= { pmora14CtrlOther 73 }
|
||
|
||
|
||
|
||
|
||
pmora14CtrlLedOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Leds Off :This OID switches off
|
||
all the Leds as a test feature.
|
||
<Help> This control initiates
|
||
a test leds turning all the LEDs
|
||
to OFF
|
||
"
|
||
::= { pmora14CtrlledTest 3 }
|
||
|
||
|
||
|
||
pmora14CtrlRedLed OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Red Leds Test :This OID switches
|
||
on all the red Leds as a test feature.
|
||
<Help> This control initiates
|
||
a test leds turning all the LEDs
|
||
to red
|
||
"
|
||
::= { pmora14CtrlledTest 2 }
|
||
|
||
|
||
|
||
pmora14CtrlGreenLed OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Green Leds Test :This OID switches
|
||
on all the green Leds as a test
|
||
feature. <Help> This control
|
||
initiates a test leds turning
|
||
all the LEDs to green
|
||
"
|
||
::= { pmora14CtrlledTest 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the maintMode article
|
||
--- *****************************************************
|
||
pmora14CtrlmaintMode OBJECT IDENTIFIER ::= { pmora14CtrlOther 74 }
|
||
|
||
|
||
|
||
|
||
pmora14CtrlMaintenance OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Maintenance Mode :This OID
|
||
sets the PM in maintenance mode
|
||
<Help> This control enables the
|
||
maintenance mode of the module
|
||
"
|
||
::= { pmora14CtrlmaintMode 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the aprManualRestart article
|
||
--- *****************************************************
|
||
pmora14CtrlaprManualRestart OBJECT IDENTIFIER ::= { pmora14CtrlLine 75 }
|
||
|
||
|
||
|
||
|
||
pmora14CtrlAprManualRestart OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
APR Manual Restart :This OID initiates
|
||
the Restart mechanism to retrieve
|
||
from the APR state.<Help> This
|
||
control initiates the Restart
|
||
mechanism to retrieve from the
|
||
APR state.
|
||
"
|
||
::= { pmora14CtrlaprManualRestart 1 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- COUNTERS
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
pmora14CntCountersReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Counters Reset:This OID resets and restarts all the counters"
|
||
::= { pmora14counters 259 }
|
||
|
||
pmora14CntCountersStop OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Counters stop:This OID stops all the counters"
|
||
::= { pmora14counters 260 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- MEASURES
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the pump1CurrentMeas article
|
||
--- *****************************************************
|
||
|
||
pmora14Mesrpump1CurrentMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 1 Laser Current :This OID
|
||
gives the Pump1 laser current (Current
|
||
=AV/10) (Unit = mA) <Help> This
|
||
measure gives the Pump1 Laser current
|
||
"
|
||
::= { pmora14MesrLine 64 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the pump1PowerMeas article
|
||
--- *****************************************************
|
||
|
||
pmora14Mesrpump1PowerMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 1 Tx Power :This OID gives
|
||
the Pump1 power value (Power =AV/20)
|
||
(Unit = mW) <Help> This measure
|
||
gives the Pump1 Power value
|
||
"
|
||
::= { pmora14MesrLine 65 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the pump1TempMeas article
|
||
--- *****************************************************
|
||
|
||
pmora14Mesrpump1TempMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 1 Temperature :This OID gives
|
||
the Pump1 TEC temperature (Temperature
|
||
=AV/256) (Unit = C)<Help> This
|
||
measure gives the Pump1 TEC temperature
|
||
"
|
||
::= { pmora14MesrLine 66 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the pump1TecCurrentMeas article
|
||
--- *****************************************************
|
||
|
||
pmora14Mesrpump1TecCurrentMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 1 TEC Current :This OID gives
|
||
the Pump1 TEC current (Current
|
||
=AV/10) (Unit = mA) <Help> This
|
||
measure gives the Pump1 TEC current
|
||
"
|
||
::= { pmora14MesrLine 67 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the pump2CurrentMeas article
|
||
--- *****************************************************
|
||
|
||
pmora14Mesrpump2CurrentMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 2 Laser Current :This OID
|
||
gives the Pump2 laser current (Current
|
||
=AV/10) (Unit = mA) <Help> This
|
||
measure gives the Pump2 Laser current
|
||
"
|
||
::= { pmora14MesrLine 68 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the pump2PowerMeas article
|
||
--- *****************************************************
|
||
|
||
pmora14Mesrpump2PowerMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 2 Tx Power :This OID gives
|
||
the Pump2 power value (Power =AV/20)
|
||
(Unit = mW) <Help> This measure
|
||
gives the Pump2 Power value
|
||
"
|
||
::= { pmora14MesrLine 69 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the pump2TempMeas article
|
||
--- *****************************************************
|
||
|
||
pmora14Mesrpump2TempMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 2 Temperature :This OID gives
|
||
the Pump2 TEC temperature (Temperature
|
||
=AV/256) (Unit = C) <Help> This
|
||
measure gives the Pump2 TEC temperature
|
||
"
|
||
::= { pmora14MesrLine 70 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the pump2TecCurrentMeas article
|
||
--- *****************************************************
|
||
|
||
pmora14Mesrpump2TecCurrentMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pump 2 TEC Current :This OID gives
|
||
the Pump2 TEC current (Current
|
||
=AV/10) (Unit = mA) <Help> This
|
||
measure gives the Pump2 TEC current
|
||
"
|
||
::= { pmora14MesrLine 71 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the totalPumpsPower article
|
||
--- *****************************************************
|
||
|
||
pmora14MesrtotalPumpsPower OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Total Pumps Power :This OID indicates
|
||
the total pumps power (Power =
|
||
AV/20) (Unit = mW) <Help> This
|
||
measure indicates the total pump
|
||
power
|
||
"
|
||
::= { pmora14MesrLine 72 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the inputCBandPower article
|
||
--- *****************************************************
|
||
|
||
pmora14MesrinputCBandPower OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Input C Band Power :This OID indicates
|
||
the input power over the C-Band
|
||
(Power =(AV-32768)*0,005) (Unit
|
||
= dBm) <Help> This measure indicates
|
||
the input power over the C-Band
|
||
"
|
||
::= { pmora14MesrLine 73 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the sBandPower article
|
||
--- *****************************************************
|
||
|
||
pmora14MesrsBandPower OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
S Band Power :This OID indicates
|
||
the input power over the S-band
|
||
(Power =(AV-32768)*0,005) (Unit
|
||
= dBm) <Help> This measure indicates
|
||
the input power over the S-Band
|
||
"
|
||
::= { pmora14MesrLine 74 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the backReflectionPumpPower article
|
||
--- *****************************************************
|
||
|
||
pmora14MesrbackReflectionPumpPower OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Back Reflection Pump Power :This
|
||
OID indicates the Back Reflection
|
||
Pump power (Power =(AV-32768)*0,005)
|
||
(Unit = dBm) <Help> This measure
|
||
indicates the Back Reflection Pump
|
||
power
|
||
"
|
||
::= { pmora14MesrLine 75 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the backReflectionPumpRatio article
|
||
--- *****************************************************
|
||
|
||
pmora14MesrbackReflectionPumpRatio OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Back Reflection Pump Ratio :This
|
||
OID indicates the Back Relfection
|
||
Pump ration (Power =(AV-32768)*0,005)
|
||
(Unit = dB) <Help> This measure
|
||
indicates the Back Reflection Pump
|
||
ratio
|
||
"
|
||
::= { pmora14MesrLine 76 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the pmTempMeas article
|
||
--- *****************************************************
|
||
|
||
pmora14MesrpmTempMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Temperature :This OID gives
|
||
the temperature of the PM (Temperature
|
||
=AV/256) (Unit = C)<Help> This
|
||
measure gives the temperature of
|
||
the module
|
||
"
|
||
::= { pmora14MesrOther 80 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- CONFIG
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group noValue
|
||
--- *****************************************************
|
||
|
||
pmora14CfgNoValue OBJECT IDENTIFIER ::= { pmora14Config 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 2191
|
||
--- *****************************************************
|
||
|
||
pmora14tablelineStartup OBJECT IDENTIFIER ::= { pmora14CfgNoValue 1 }
|
||
|
||
|
||
|
||
pmora14CfgoraModuleCtrl OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on the module
|
||
:This OID configures the default
|
||
initialisation settings of the
|
||
Raman module
|
||
"
|
||
::= { pmora14tablelineStartup 2 }
|
||
|
||
|
||
|
||
pmora14CfgautoRestartDelay OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on autorestart
|
||
delay :This OID configures the
|
||
default period on the autorestart
|
||
"
|
||
::= { pmora14tablelineStartup 3 }
|
||
|
||
|
||
|
||
pmora14CfgramanGain OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on the Raman
|
||
Gain :This OID configures the
|
||
default gain on the Raman module
|
||
"
|
||
::= { pmora14tablelineStartup 4 }
|
||
|
||
|
||
|
||
pmora14CfgramanMode OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Raman mode
|
||
:This OID configures the default
|
||
Raman mode
|
||
"
|
||
::= { pmora14tablelineStartup 5 }
|
||
|
||
|
||
|
||
pmora14CfgtiltValue OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on the tilt value
|
||
:This OID configures the default
|
||
tilt on the line amplifier.
|
||
"
|
||
::= { pmora14tablelineStartup 6 }
|
||
|
||
|
||
|
||
pmora14CfghighBackreflectionThreshold OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on the backreflection
|
||
threshold :This OID configures
|
||
the default threshold on the backreflection
|
||
"
|
||
::= { pmora14tablelineStartup 7 }
|
||
|
||
|
||
|
||
pmora14CfgsBandThreshold OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on the S band
|
||
threshold :This OID configures
|
||
the default threshold on the S
|
||
band
|
||
"
|
||
::= { pmora14tablelineStartup 8 }
|
||
|
||
|
||
|
||
pmora14Cfgpump1ManualPower OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on the pump power
|
||
:This OID configures the default
|
||
value on the power
|
||
"
|
||
::= { pmora14tablelineStartup 9 }
|
||
|
||
|
||
|
||
pmora14Cfgpump2ManualPower OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on the pump power
|
||
:This OID configures the default
|
||
value on the power
|
||
"
|
||
::= { pmora14tablelineStartup 10 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group labels
|
||
--- *****************************************************
|
||
|
||
pmora14CfgLabels OBJECT IDENTIFIER ::= { pmora14Config 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table NO_VALUE
|
||
--- *****************************************************
|
||
|
||
pmora14CfgLabelclientTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmora14CfgLabelclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pmora14CfgLabels 1 }
|
||
|
||
|
||
pmora14CfgLabelclientEntry OBJECT-TYPE
|
||
SYNTAX Pmora14CfgLabelclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the labels
|
||
table
|
||
"
|
||
INDEX { pmora14CfgLabelclientIndex }
|
||
::= { pmora14CfgLabelclientTable 1 }
|
||
|
||
|
||
Pmora14CfgLabelclientEntry ::=
|
||
SEQUENCE {
|
||
pmora14CfgLabelclientIndex
|
||
INTEGER,
|
||
pmora14CfgLabelclientPortn
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmora14CfgLabelclientIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the labelclient
|
||
table
|
||
"
|
||
::= { pmora14CfgLabelclientEntry 1 }
|
||
|
||
|
||
pmora14CfgLabelclientPortn OBJECT-TYPE
|
||
SYNTAX DisplayString( SIZE(1..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default settings on the label
|
||
of the Ports :These registers
|
||
configures the default initialisation
|
||
settings of the labels of the ports.
|
||
"
|
||
::= { pmora14CfgLabelclientEntry 3 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table NO_VALUE
|
||
--- *****************************************************
|
||
|
||
pmora14CfgLabellineTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmora14CfgLabellineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pmora14CfgLabels 2 }
|
||
|
||
|
||
pmora14CfgLabellineEntry OBJECT-TYPE
|
||
SYNTAX Pmora14CfgLabellineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the labels
|
||
table
|
||
"
|
||
INDEX { pmora14CfgLabellineIndex }
|
||
::= { pmora14CfgLabellineTable 1 }
|
||
|
||
|
||
Pmora14CfgLabellineEntry ::=
|
||
SEQUENCE {
|
||
pmora14CfgLabellineIndex
|
||
INTEGER,
|
||
pmora14CfgLabellinePortn
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmora14CfgLabellineIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the labelline
|
||
table
|
||
"
|
||
::= { pmora14CfgLabellineEntry 1 }
|
||
|
||
|
||
pmora14CfgLabellinePortn OBJECT-TYPE
|
||
SYNTAX DisplayString( SIZE(1..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default settings on the label
|
||
of the lines :These registers
|
||
configures the default initialisation
|
||
settings of the labels of the lines.
|
||
"
|
||
::= { pmora14CfgLabellineEntry 3 }
|
||
|
||
|
||
|
||
pmora14CfgWriteConfiguration OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Write configuration to module:This OID
|
||
writes the complete configuration to the module"
|
||
::= { pmora14Config 257 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- TRAP OBJECTS
|
||
--- *****************************************************
|
||
|
||
pmora14trapBoardNumber OBJECT-TYPE
|
||
SYNTAX INTEGER(1..64)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Last module which generates a trap"
|
||
::= { pmora14traps 4 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- GLOBAL TRAPS
|
||
--- *****************************************************
|
||
|
||
pmora14LineTrapCritGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmora14AlmLineFail, pmora14AlmLineHwFail, pmora14trapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMORA14 Line Fail ON"
|
||
--&ACTIONS { log, critical }
|
||
--&MATCH { pmora14AlmLineFail "on", pmora14AlmLineHwFail "*", pmora14trapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm appears on PMORA14 in slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMORA14 Line HW Fail ON (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmora14AlmLineFail "*", pmora14AlmLineHwFail "on", pmora14trapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm appears on PMORA14 in slot $3 ($A)"
|
||
DESCRIPTION "Critical Line default is activated"
|
||
::= { pmora14traps 34 }
|
||
|
||
pmora14LineTrapCritGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmora14AlmLineFail, pmora14AlmLineHwFail, pmora14trapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMORA14 Line Fail OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS {"PMORA14 Line Fail ON"}
|
||
--&MATCH { pmora14AlmLineFail "on", pmora14AlmLineHwFail "*", pmora14trapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm disappears on PMORA14 in slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMORA14 Line HW Fail OFF (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmora14AlmLineFail "*", pmora14AlmLineHwFail "on", pmora14trapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm disappears on PMORA14 in slot $3 ($A)"
|
||
DESCRIPTION "Critical Line default disappeared"
|
||
::= { pmora14traps 35 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- PORTS TRAPS
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- HW TRAPS
|
||
--- *****************************************************
|
||
|
||
pmora14PowerTrapUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmora14AlmDefFuseB, pmora14AlmDefFuseA , pmora14trapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMORA Fuse A Fail ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmora14AlmDefFuseB "*", pmora14AlmDefFuseA "on", pmora14trapBoardNumber "$3"}
|
||
--&MESG "Power Input A Fail on PMORA in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMORA Fuse B Fail ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmora14AlmDefFuseB "on", pmora14AlmDefFuseA "*", pmora14trapBoardNumber "$3"}
|
||
--&MESG "Power Input B Fail on PMORA in Slot $3 ($A)"
|
||
DESCRIPTION "Urgent power supply default is activated"
|
||
::= { pmora14traps 50 }
|
||
pmora14PowerTrapUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmora14AlmDefFuseB, pmora14AlmDefFuseA , pmora14trapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMORA Fuse A&B Fail OFF"
|
||
--&ACTIONS { log, normal}
|
||
--&CLEARS { "PMORA Fuse A Fail ON", "PMORA Fuse B Fail ON" }
|
||
--&MATCH { pmora14AlmDefFuseB "on", pmora14AlmDefFuseA "on", pmora14trapBoardNumber "$3"}
|
||
--&MESG "Power Inputs A and B Present on PMORA in Slot $3 ($A)"
|
||
DESCRIPTION "Urgent power supply default disappeared"
|
||
::= { pmora14traps 51 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
END
|