700 lines
18 KiB
Plaintext
700 lines
18 KiB
Plaintext
CYAN-DTM-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
Integer32,
|
|
Unsigned32
|
|
FROM SNMPv2-SMI
|
|
|
|
DisplayString
|
|
FROM SNMPv2-TC
|
|
|
|
CyanLEDTc,
|
|
CyanOffOnTc,
|
|
CyanActvStdbyTc,
|
|
CyanAdminStateTc,
|
|
CyanOpStateQualTc,
|
|
CyanSecServiceStateTc,
|
|
CyanOpStateTc
|
|
FROM CYAN-TC-MIB
|
|
|
|
CyanTypeTc,
|
|
cyanEntityModules
|
|
FROM CYAN-MIB
|
|
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF;
|
|
|
|
|
|
cyanDtmModule MODULE-IDENTITY
|
|
LAST-UPDATED "201412070545Z" -- Sun Dec 7 05:45:27 2014
|
|
ORGANIZATION "Cyan, Inc."
|
|
CONTACT-INFO
|
|
"
|
|
E-mail: support@cyaninc.com
|
|
|
|
Postal: Cyan, Inc.
|
|
1390 N. McDowell Blvd., # G-327
|
|
Petaluma, CA 94954
|
|
USA
|
|
|
|
Tel: +1-707-735-2300"
|
|
|
|
DESCRIPTION "MIB module for Digital Transmission Module (DTM)"
|
|
|
|
REVISION "201412070545Z" -- Sun Dec 7 05:45:27 2014
|
|
DESCRIPTION "Release 6.0 build 1416362081"
|
|
|
|
::= { cyanEntityModules 120 }
|
|
|
|
cyanDtmMibObjects OBJECT IDENTIFIER ::={ cyanDtmModule 1 }
|
|
|
|
cyanDtmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CyanDtmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of Dtm entries."
|
|
::= { cyanDtmMibObjects 1 }
|
|
|
|
cyanDtmEntry OBJECT-TYPE
|
|
SYNTAX CyanDtmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry of Dtm."
|
|
INDEX {
|
|
cyanDtmShelfId ,
|
|
cyanDtmDtmId
|
|
}
|
|
::= { cyanDtmTable 1 }
|
|
|
|
CyanDtmEntry ::=
|
|
SEQUENCE {
|
|
cyanDtmShelfId Unsigned32,
|
|
cyanDtmDtmId Unsigned32,
|
|
cyanDtmActiveLed CyanLEDTc,
|
|
cyanDtmActivestandbyState CyanActvStdbyTc,
|
|
cyanDtmAdminState CyanAdminStateTc,
|
|
cyanDtmAlarmLed CyanLEDTc,
|
|
cyanDtmAssetTag DisplayString,
|
|
cyanDtmAutoinserviceSoakTimeSec Integer32,
|
|
cyanDtmBaseMacAddress DisplayString,
|
|
cyanDtmCurrCyanSwBuildVersions DisplayString,
|
|
cyanDtmCurrCyanSwRelease DisplayString,
|
|
cyanDtmCurrent Integer32,
|
|
cyanDtmDescription DisplayString,
|
|
cyanDtmExhaustAirTemp Integer32,
|
|
cyanDtmExhaustTempAlarmHighThres Integer32,
|
|
cyanDtmExhaustTempAlarmLowThres Integer32,
|
|
cyanDtmExhaustTempWarnHighThres Integer32,
|
|
cyanDtmExhaustTempWarnLowThres Integer32,
|
|
cyanDtmExpectedTemperatureRise Integer32,
|
|
cyanDtmIdentifier DisplayString,
|
|
cyanDtmIntakeAirTemp Integer32,
|
|
cyanDtmIntakeTempAlarmHighThres Integer32,
|
|
cyanDtmIntakeTempAlarmLowThres Integer32,
|
|
cyanDtmIntakeTempWarnHighThres Integer32,
|
|
cyanDtmIntakeTempWarnLowThres Integer32,
|
|
cyanDtmLedTest Unsigned32,
|
|
cyanDtmMacBlockSize Unsigned32,
|
|
cyanDtmMfgCleiCode DisplayString,
|
|
cyanDtmMfgEciCode DisplayString,
|
|
cyanDtmMfgModuleId Unsigned32,
|
|
cyanDtmMfgPartNumber DisplayString,
|
|
cyanDtmMfgRevision DisplayString,
|
|
cyanDtmMfgSerialNumber DisplayString,
|
|
cyanDtmName DisplayString,
|
|
cyanDtmOidClass DisplayString,
|
|
cyanDtmOperState CyanOpStateTc,
|
|
cyanDtmOperStateQual CyanOpStateQualTc,
|
|
cyanDtmOssLabel DisplayString,
|
|
cyanDtmOvervoltageThreshold Integer32,
|
|
cyanDtmOwner DisplayString,
|
|
cyanDtmPartNumber DisplayString,
|
|
cyanDtmPowerLed CyanLEDTc,
|
|
cyanDtmPsuTemperature Integer32,
|
|
cyanDtmPwrFeedAStatus CyanOffOnTc,
|
|
cyanDtmPwrFeedAVoltage Integer32,
|
|
cyanDtmPwrFeedBStatus CyanOffOnTc,
|
|
cyanDtmPwrFeedBVoltage Integer32,
|
|
cyanDtmRevertCyanSwBuildVersions DisplayString,
|
|
cyanDtmRevertCyanSwRelease DisplayString,
|
|
cyanDtmSecServState CyanSecServiceStateTc,
|
|
cyanDtmSynchLed CyanLEDTc,
|
|
cyanDtmType CyanTypeTc,
|
|
cyanDtmUndervoltageThreshold Integer32,
|
|
cyanDtmUpgradeCyanSwBuildVersions DisplayString,
|
|
cyanDtmUpgradeCyanSwRelease DisplayString
|
|
}
|
|
|
|
cyanDtmShelfId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shelf Id"
|
|
|
|
::= { cyanDtmEntry 1 }
|
|
cyanDtmDtmId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Dtm Module Id"
|
|
|
|
::= { cyanDtmEntry 2 }
|
|
|
|
cyanDtmActiveLed OBJECT-TYPE
|
|
SYNTAX CyanLEDTc
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active LED status"
|
|
|
|
::= { cyanDtmEntry 3 }
|
|
|
|
cyanDtmActivestandbyState OBJECT-TYPE
|
|
SYNTAX CyanActvStdbyTc
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active/standby state"
|
|
|
|
::= { cyanDtmEntry 4 }
|
|
|
|
cyanDtmAdminState OBJECT-TYPE
|
|
SYNTAX CyanAdminStateTc
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Administrative state"
|
|
|
|
::= { cyanDtmEntry 5 }
|
|
|
|
cyanDtmAlarmLed OBJECT-TYPE
|
|
SYNTAX CyanLEDTc
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm LED status"
|
|
|
|
::= { cyanDtmEntry 6 }
|
|
|
|
cyanDtmAssetTag OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..124))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Asset Tag"
|
|
|
|
::= { cyanDtmEntry 7 }
|
|
|
|
cyanDtmAutoinserviceSoakTimeSec OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Auto-In-Service soak time"
|
|
|
|
::= { cyanDtmEntry 8 }
|
|
|
|
cyanDtmBaseMacAddress OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Base MAC address of a range of addresses"
|
|
|
|
::= { cyanDtmEntry 9 }
|
|
|
|
cyanDtmCurrCyanSwBuildVersions OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current Cyan software build versions"
|
|
|
|
::= { cyanDtmEntry 10 }
|
|
|
|
cyanDtmCurrCyanSwRelease OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current Cyan software release"
|
|
|
|
::= { cyanDtmEntry 11 }
|
|
|
|
cyanDtmCurrent OBJECT-TYPE
|
|
SYNTAX Integer32 -- real32 * 1000
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current Draw"
|
|
|
|
::= { cyanDtmEntry 12 }
|
|
|
|
cyanDtmDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description"
|
|
|
|
::= { cyanDtmEntry 13 }
|
|
|
|
cyanDtmExhaustAirTemp OBJECT-TYPE
|
|
SYNTAX Integer32 (-128000..128000) -- Float value * 1000
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Exhaust air temperature"
|
|
|
|
::= { cyanDtmEntry 14 }
|
|
|
|
cyanDtmExhaustTempAlarmHighThres OBJECT-TYPE
|
|
SYNTAX Integer32 (-128000..128000) -- Float value * 1000
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High alarm threshold for exhaust air temperature"
|
|
|
|
::= { cyanDtmEntry 15 }
|
|
|
|
cyanDtmExhaustTempAlarmLowThres OBJECT-TYPE
|
|
SYNTAX Integer32 (-128000..128000) -- Float value * 1000
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Low alarm threshold for exhaust air temperature"
|
|
|
|
::= { cyanDtmEntry 16 }
|
|
|
|
cyanDtmExhaustTempWarnHighThres OBJECT-TYPE
|
|
SYNTAX Integer32 (-128000..128000) -- Float value * 1000
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High warning threshold for exhaust air temperature"
|
|
|
|
::= { cyanDtmEntry 17 }
|
|
|
|
cyanDtmExhaustTempWarnLowThres OBJECT-TYPE
|
|
SYNTAX Integer32 (-128000..128000) -- Float value * 1000
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Low warning threshold for exhaust air temperature"
|
|
|
|
::= { cyanDtmEntry 18 }
|
|
|
|
cyanDtmExpectedTemperatureRise OBJECT-TYPE
|
|
SYNTAX Integer32 -- Float Value * 1000
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Expected temperature rise"
|
|
|
|
::= { cyanDtmEntry 19 }
|
|
|
|
cyanDtmIdentifier OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"string OID"
|
|
|
|
::= { cyanDtmEntry 20 }
|
|
|
|
cyanDtmIntakeAirTemp OBJECT-TYPE
|
|
SYNTAX Integer32 (-128000..128000) -- Float value * 1000
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In-take air temperature"
|
|
|
|
::= { cyanDtmEntry 21 }
|
|
|
|
cyanDtmIntakeTempAlarmHighThres OBJECT-TYPE
|
|
SYNTAX Integer32 (-128000..128000) -- Float value * 1000
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High alarm threshold for in-take air temperature"
|
|
|
|
::= { cyanDtmEntry 22 }
|
|
|
|
cyanDtmIntakeTempAlarmLowThres OBJECT-TYPE
|
|
SYNTAX Integer32 (-128000..128000) -- Float value * 1000
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Low alarm threshold for in-take air temperature"
|
|
|
|
::= { cyanDtmEntry 23 }
|
|
|
|
cyanDtmIntakeTempWarnHighThres OBJECT-TYPE
|
|
SYNTAX Integer32 (-128000..128000) -- Float value * 1000
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High warning threshold for in-take air temperature"
|
|
|
|
::= { cyanDtmEntry 24 }
|
|
|
|
cyanDtmIntakeTempWarnLowThres OBJECT-TYPE
|
|
SYNTAX Integer32 (-128000..128000) -- Float value * 1000
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Low warning threshold for in-take air temperature"
|
|
|
|
::= { cyanDtmEntry 25 }
|
|
|
|
cyanDtmLedTest OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Change value of this attribute to run LED test on this module"
|
|
|
|
::= { cyanDtmEntry 26 }
|
|
|
|
cyanDtmMacBlockSize OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of MAC addresses allocated from the base MAC address"
|
|
|
|
::= { cyanDtmEntry 27 }
|
|
|
|
cyanDtmMfgCleiCode OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..10))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Common Language Equipment Identifier"
|
|
|
|
::= { cyanDtmEntry 28 }
|
|
|
|
cyanDtmMfgEciCode OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..6))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Equipment Catalog Item"
|
|
|
|
::= { cyanDtmEntry 29 }
|
|
|
|
cyanDtmMfgModuleId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module ID"
|
|
|
|
::= { cyanDtmEntry 30 }
|
|
|
|
cyanDtmMfgPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manufacturing part number"
|
|
|
|
::= { cyanDtmEntry 31 }
|
|
|
|
cyanDtmMfgRevision OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..4))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mfg revision number"
|
|
|
|
::= { cyanDtmEntry 32 }
|
|
|
|
cyanDtmMfgSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mfg serial number"
|
|
|
|
::= { cyanDtmEntry 33 }
|
|
|
|
cyanDtmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cyan name"
|
|
|
|
::= { cyanDtmEntry 34 }
|
|
|
|
cyanDtmOidClass OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OID Class"
|
|
|
|
::= { cyanDtmEntry 35 }
|
|
|
|
cyanDtmOperState OBJECT-TYPE
|
|
SYNTAX CyanOpStateTc
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Primary Operation State"
|
|
|
|
::= { cyanDtmEntry 36 }
|
|
|
|
cyanDtmOperStateQual OBJECT-TYPE
|
|
SYNTAX CyanOpStateQualTc
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation state qualifier"
|
|
|
|
::= { cyanDtmEntry 37 }
|
|
|
|
cyanDtmOssLabel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CyMS label"
|
|
|
|
::= { cyanDtmEntry 38 }
|
|
|
|
cyanDtmOvervoltageThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 -- real32 * 1000
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Over-voltage warning threshold"
|
|
|
|
::= { cyanDtmEntry 39 }
|
|
|
|
cyanDtmOwner OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Owner"
|
|
|
|
::= { cyanDtmEntry 40 }
|
|
|
|
cyanDtmPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..11))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cyan part number"
|
|
|
|
::= { cyanDtmEntry 41 }
|
|
|
|
cyanDtmPowerLed OBJECT-TYPE
|
|
SYNTAX CyanLEDTc
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power LED status"
|
|
|
|
::= { cyanDtmEntry 42 }
|
|
|
|
cyanDtmPsuTemperature OBJECT-TYPE
|
|
SYNTAX Integer32 (-25000..85000) -- Float value * 1000
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature reading in the power supply"
|
|
|
|
::= { cyanDtmEntry 43 }
|
|
|
|
cyanDtmPwrFeedAStatus OBJECT-TYPE
|
|
SYNTAX CyanOffOnTc
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of power supply A"
|
|
|
|
::= { cyanDtmEntry 44 }
|
|
|
|
cyanDtmPwrFeedAVoltage OBJECT-TYPE
|
|
SYNTAX Integer32 -- real32 * 1000
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Voltage level of power supply A"
|
|
|
|
::= { cyanDtmEntry 45 }
|
|
|
|
cyanDtmPwrFeedBStatus OBJECT-TYPE
|
|
SYNTAX CyanOffOnTc
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of power supply B"
|
|
|
|
::= { cyanDtmEntry 46 }
|
|
|
|
cyanDtmPwrFeedBVoltage OBJECT-TYPE
|
|
SYNTAX Integer32 -- real32 * 1000
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Voltage level of power supply B"
|
|
|
|
::= { cyanDtmEntry 47 }
|
|
|
|
cyanDtmRevertCyanSwBuildVersions OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Revert Cyan software build versions"
|
|
|
|
::= { cyanDtmEntry 48 }
|
|
|
|
cyanDtmRevertCyanSwRelease OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Revert Cyan software release"
|
|
|
|
::= { cyanDtmEntry 49 }
|
|
|
|
cyanDtmSecServState OBJECT-TYPE
|
|
SYNTAX CyanSecServiceStateTc
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Secondary service state"
|
|
|
|
::= { cyanDtmEntry 50 }
|
|
|
|
cyanDtmSynchLed OBJECT-TYPE
|
|
SYNTAX CyanLEDTc
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Synch LED status"
|
|
|
|
::= { cyanDtmEntry 51 }
|
|
|
|
cyanDtmType OBJECT-TYPE
|
|
SYNTAX CyanTypeTc
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Equipment type"
|
|
|
|
::= { cyanDtmEntry 52 }
|
|
|
|
cyanDtmUndervoltageThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 -- real32 * 1000
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Under-voltage warning threshold"
|
|
|
|
::= { cyanDtmEntry 53 }
|
|
|
|
cyanDtmUpgradeCyanSwBuildVersions OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Upgrade Cyan software build versions"
|
|
|
|
::= { cyanDtmEntry 54 }
|
|
|
|
cyanDtmUpgradeCyanSwRelease OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Upgrade Cyan software release"
|
|
|
|
::= { cyanDtmEntry 55 }
|
|
|
|
cyanDtmObjectGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cyanDtmActiveLed,
|
|
cyanDtmActivestandbyState,
|
|
cyanDtmAdminState,
|
|
cyanDtmAlarmLed,
|
|
cyanDtmAssetTag,
|
|
cyanDtmAutoinserviceSoakTimeSec,
|
|
cyanDtmBaseMacAddress,
|
|
cyanDtmCurrCyanSwBuildVersions,
|
|
cyanDtmCurrCyanSwRelease,
|
|
cyanDtmCurrent,
|
|
cyanDtmDescription,
|
|
cyanDtmExhaustAirTemp,
|
|
cyanDtmExhaustTempAlarmHighThres,
|
|
cyanDtmExhaustTempAlarmLowThres,
|
|
cyanDtmExhaustTempWarnHighThres,
|
|
cyanDtmExhaustTempWarnLowThres,
|
|
cyanDtmExpectedTemperatureRise,
|
|
cyanDtmIdentifier,
|
|
cyanDtmIntakeAirTemp,
|
|
cyanDtmIntakeTempAlarmHighThres,
|
|
cyanDtmIntakeTempAlarmLowThres,
|
|
cyanDtmIntakeTempWarnHighThres,
|
|
cyanDtmIntakeTempWarnLowThres,
|
|
cyanDtmLedTest,
|
|
cyanDtmMacBlockSize,
|
|
cyanDtmMfgCleiCode,
|
|
cyanDtmMfgEciCode,
|
|
cyanDtmMfgModuleId,
|
|
cyanDtmMfgPartNumber,
|
|
cyanDtmMfgRevision,
|
|
cyanDtmMfgSerialNumber,
|
|
cyanDtmName,
|
|
cyanDtmOidClass,
|
|
cyanDtmOperState,
|
|
cyanDtmOperStateQual,
|
|
cyanDtmOssLabel,
|
|
cyanDtmOvervoltageThreshold,
|
|
cyanDtmOwner,
|
|
cyanDtmPartNumber,
|
|
cyanDtmPowerLed,
|
|
cyanDtmPsuTemperature,
|
|
cyanDtmPwrFeedAStatus,
|
|
cyanDtmPwrFeedAVoltage,
|
|
cyanDtmPwrFeedBStatus,
|
|
cyanDtmPwrFeedBVoltage,
|
|
cyanDtmRevertCyanSwBuildVersions,
|
|
cyanDtmRevertCyanSwRelease,
|
|
cyanDtmSecServState,
|
|
cyanDtmSynchLed,
|
|
cyanDtmType,
|
|
cyanDtmUndervoltageThreshold,
|
|
cyanDtmUpgradeCyanSwBuildVersions,
|
|
cyanDtmUpgradeCyanSwRelease
|
|
}
|
|
|
|
STATUS current
|
|
DESCRIPTION "Group of objects that comes with Dtm module"
|
|
::= {cyanDtmModule 20}
|
|
|
|
cyanDtmCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The basic info needed to be a cyan Dtm"
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
cyanDtmObjectGroup
|
|
}
|
|
::= { cyanDtmModule 30 }
|
|
|
|
|
|
END
|
|
|