-- SiteBoss 350 MIB
-- v 4.11 December 11 2014
-- Copyright (c) 2014 by Asentria Corporation. All rights reserved.
SITEBOSS-350-STD-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayString
FROM SNMPv2-TC
IpAddress, TimeTicks, Integer32,
MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE
FROM SNMPv2-SMI
asentria
FROM ASENTRIA-ROOT-MIB;
--***************************************************************************************
--MODULE IDENTITY
--***************************************************************************************
s350 MODULE-IDENTITY
LAST-UPDATED "201412110411Z"
ORGANIZATION "Asentria Corporation"
CONTACT-INFO
"Phone: 206-344-8800
Fax: 206-344-2116
Email: support@asentria.com"
DESCRIPTION
"MIB module for managing Asentria SiteBoss 350"
REVISION "201412110411Z"
DESCRIPTION
"-v4.11
-Changed analog-input fuel sensor objects from Integer32 to DisplayString (OMX-1177).
-Added missing ipv6DefaultRouter object (OMX-1175).
-Applicable since unit version 2.10.580."
REVISION "201410160410Z"
DESCRIPTION
"-v4.10
-Added espcAIDisplayFormat object (OMX-1112).
-Removed espcAIPolarity, espcAIConvHighSign, espcAIConvLowSign objects (OMX-1113).
-Applicable since unit version 2.10.460."
REVISION "201410030409Z"
DESCRIPTION
"-v4.09
-Changed analog input objects from Integer32 to DisplayString.
-Applicable since unit version 2.10.460."
REVISION "201408140408Z"
DESCRIPTION
"-v4.08
-Fixed description for wirelessConnIP objects (OMX-1061).
-Applicable since unit version 2.10.390."
REVISION "201407030407Z"
DESCRIPTION
"-v4.07
-Fixed wirelessIdleTimeout (OMX-1037).
-Fixed CPE status objects (OMX-1036).
-Applicable since unit version 2.10.390."
REVISION "201406240406Z"
DESCRIPTION
"-v4.06
-Fixed CPE status objects.
-Fixed ipRestrictionMask wrong type (OMX-743).
-Applicable since unit version 2.10.340."
REVISION "201406170405Z"
DESCRIPTION
"-v4.05
-Added various missing objects (OMX-751).
-Added CPE objects (OMX-162).
-Added ACDM objects (OMX-683).
-Removed CRDB/MLR objects (OMX-1014).
-Applicable since unit version 2.10.340."
REVISION "201404110404Z"
DESCRIPTION
"-v4.04
-Clarified relay and power output function and documentation (OMX-926).
-Applicable since unit version 2.10.300."
REVISION "201401170403Z"
DESCRIPTION
"-v4.03
-Added IPv6 objects (OMX-705).
-Added power distribution objects (powerDistributionStatus branch) (OMX-708).
-Added ftpPushPermissions (OMX-737).
-Added snmpProxy objects (OMX-747).
-Applicable since unit version 2.10.150."
REVISION "201312040402Z"
DESCRIPTION
"-v4.02
-Added fsGenEnable (OMX-661).
-Applicable since unit version 2.10.110."
REVISION "201310160401Z"
DESCRIPTION
"-v4.01
-Added genSetRelayTable for multiple genset ignition relays (OMX-577).
-Added genSetCCDelay object (OMX-589).
-Applicable since unit version 2.09.625."
REVISION "201308190400Z"
DESCRIPTION
"-v4.00
-New MIB for S350.
-Applicable since unit version 2.09.610."
::= { asentria 18 }
--1.3.6.1.4.1.3052.18
--***************************************************************************************
--Concise MIB View: Top Level Branches
--***************************************************************************************
-- status .1
-- eventSensorStatus .1.1
-- esPointTable .1.1.1
-- dataEventStatus .1.2
-- deStatusTable .1.2.1
-- powerDistributionStatus .1.5
-- fuelSensorStatus .1.6
-- fsStatusTable .1.6.1
-- wirelessModemStatus .1.7
-- acPowerMonitorStatus .1.8
-- acpmStatusTable .1.8.1
-- batteryMonitorStatus .1.10
-- bmStatusTable .1.10.1
-- bmJarStatusTable .1.10.2
-- config .2
-- eventSensorBasics .2.1
-- esNumberEventSensors .2.1.1
-- esTable .2.1.2
-- esNewSensors .2.1.3
-- eventSensorPointConfig .2.2
-- esPointConfigTempTable .2.2.1
-- esPointConfigCCTable .2.2.2
-- esPointConfigHumidTable .2.2.3
-- esPointConfigAITable .2.2.5
-- esPointConfigOutputTable .2.2.6
-- serialPorts .2.3
-- numberPorts .2.3.1
-- portConfigTable .2.3.2
-- network .2.4
-- interface .2.4.1
-- defaultRouter .2.4.2
-- dnsTable .2.4.3
-- hostname .2.4.4
-- hostTable .2.4.5
-- ncpDuplex .2.4.6
-- ncpTimeout .2.4.7
-- snmp .2.4.8
-- ftpPush .2.4.9
-- routing .2.4.11
-- netSecurity .2.4.12
-- trap .2.4.14
-- wireless .2.4.16
-- email .2.4.17
-- netAdvanced .2.4.18
-- web .2.4.19
-- ipv6 .2.4.21
-- cpe .2.4.22
-- time .2.8
-- clock .2.8.1
-- console .2.10
-- unitSecurity .2.11
-- secCore .2.11.1
-- secUserTable .2.11.2
-- secFactory .2.11.3
-- event .2.12
-- evCore .2.12.1
-- evSched1 .2.12.5
-- evSched2 .2.12.6
-- evShskLowTable .2.12.7
-- evShskHighTable .2.12.8
-- evNoSensor .2.12.9
-- fuelSensor .2.12.11
-- fuelSensorGeneralTable .2.12.11.1
-- fuelSensorTankTable .2.12.11.2
-- fuelSensorCustomTankTable .2.12.11.3
-- fuelSensorVolumeTable .2.12.11.4
-- fuelSensorDisconnectTable .2.12.11.5
-- fuelSensorSuddenChangeTable .2.12.11.6
-- fuelSensorSlowChangeTable .2.12.11.7
-- fuelSensorLevelsAutoAdjustTable .2.12.11.8
-- acPowerMonitor .2.12.12
-- batteryMonitor .2.12.14
-- evLocation .2.12.15
-- evReset .2.12.16
-- evSleep .2.12.17
-- evGlobal .2.12.18
-- accessControl .2.12.21
-- action .2.14
-- actionSched .2.14.3
-- actionAsentria .2.14.4
-- actionHostTable .2.14.6
-- actionEmailTable .2.14.7
-- actionParseError .2.14.8
-- sys .2.16
-- sysTime .2.16.1
-- sysPT .2.16.2
-- sysMTU .2.16.3
-- sysAnswerString .2.16.4
-- sysEventFileID .2.16.6
-- sysEscapeCharacter .2.16.7
-- sysTimeStamp .2.16.8
-- sysLog .2.16.9
-- sysCRDB .2.16.10
-- sysCharMask .2.16.11
-- sysPrompt .2.16.12
-- sysBootStatus .2.16.13
-- sysLoc .2.16.14
-- sysSleep .2.16.16
-- sysFileTransfer .2.16.17
-- sysUpdate .2.16.18
-- auditLog .2.17
-- scripting .2.18
-- scrGlobalEnable .2.18.1
-- scrDTRCtrlPortEnableTable .2.18.2
-- scrTable .2.18.3
-- scrVolatileStringTable .2.18.4
-- scrVolatileIntTable .2.18.5
-- scrNonVolatileStringTable .2.18.6
-- scrNonVolatileIntTable .2.18.7
-- generator .2.19
-- genSet .2.19.1
-- genSetRelay .2.19.1.2
-- genSetCc .2.19.1.3
-- genRun .2.19.2
-- genRunNonstartEvent .2.19.2.7
-- calendar .2.20
-- productIds .3
-- siteName 3.1
-- thisProduct .3.2
-- stockTrapString .3.3
-- trapEventTypeNumber .3.4
-- trapEventTypeName .3.5
-- trapIncludedValue .3.6
-- trapIncludedString .3.7
-- trapTypeString .3.8
-- trapEventClassNumber .3.9
-- trapEventClassName .3.10
-- keyInterface .4.0
--***************************************************************************************
--Complete MIB View: All Objects
--***************************************************************************************
-- status .1
-- eventSensorStatus .1.1
-- esPointTable .1.1.1
-- esPointEntry .1.1.1.1
-- esIndexES .1.1.1.1.1
-- esIndexPC .1.1.1.1.2
-- esIndexPoint .1.1.1.1.3
-- esPointName .1.1.1.1.4
-- esPointInEventState .1.1.1.1.5
-- esPointValueInt .1.1.1.1.6
-- esPointValueStr .1.1.1.1.7
-- esPointTimeLastChange .1.1.1.1.8
-- esPointTimetickLastChange .1.1.1.1.9
-- esPointAliasValueStr .1.1.1.1.10
-- dataEventStatus .1.2
-- deStatusTable .1.2.1
-- deStatusEntry .1.2.1.1
-- deStatusIndex .1.2.1.1.1
-- deStatusName .1.2.1.1.2
-- deStatusCounter .1.2.1.1.3
-- deStatusThreshold .1.2.1.1.4
-- powerDistributionStatus .1.5
-- pdConfig .1.5.1
-- pdNextGen .1.5.4
-- pdnTable .1.5.4.1
-- pdnEntry .1.5.4.1.1
-- pdnIndexPD .1.5.4.1.1.1
-- pdnIndexOutput .1.5.4.1.1.2
-- pdnConfig .1.5.4.1.1.3
-- pdnMainCurrentInEventState .1.5.4.1.1.4
-- pdnMainCurrentValue .1.5.4.1.1.5
-- pdnMainCurrentValueStr .1.5.4.1.1.6
-- pdnMainCurrentDeadband .1.5.4.1.1.7
-- pdnMainCurrentVHighCurrent .1.5.4.1.1.8
-- pdnMainCurrentHighCurrent .1.5.4.1.1.9
-- pdnMainCurrentLowCurrent .1.5.4.1.1.10
-- pdnMainCurrentVLowCurrent .1.5.4.1.1.11
-- pdnMainVoltageInEventState .1.5.4.1.1.12
-- pdnMainVoltageValue .1.5.4.1.1.13
-- pdnMainVoltageValueStr .1.5.4.1.1.14
-- pdnMainVoltageDeadband .1.5.4.1.1.15
-- pdnMainVoltageVHighVoltage .1.5.4.1.1.16
-- pdnMainVoltageHighVoltage .1.5.4.1.1.17
-- pdnMainVoltageLowVoltage .1.5.4.1.1.18
-- pdnMainVoltageVLowVoltage .1.5.4.1.1.19
-- pdnMainPowerValue .1.5.4.1.1.20
-- pdnMainPowerValueStr .1.5.4.1.1.21
-- pdnOutputCurrentInEventState .1.5.4.1.1.22
-- pdnOutputCurrentValue .1.5.4.1.1.23
-- pdnOutputCurrentValueStr .1.5.4.1.1.24
-- pdnOutputCurrentDeadband .1.5.4.1.1.25
-- pdnOutputCurrentVHighCurrent .1.5.4.1.1.26
-- pdnOutputCurrentHighCurrent .1.5.4.1.1.27
-- pdnOutputCurrentLowCurrent .1.5.4.1.1.28
-- pdnOutputCurrentVLowCurrent .1.5.4.1.1.29
-- pdnOutputFuseInEventState .1.5.4.1.1.30
-- pdnOutputFuseValueStr .1.5.4.1.1.31
-- pdnMainCombinedStatus .1.5.4.1.1.32
-- pdnOutputCombinedStatusBlock1 .1.5.4.1.1.33
-- pdnOutputCombinedStatusBlock2 .1.5.4.1.1.34
-- pdnDeviceCurrentValue .1.5.4.1.1.35
-- pdnDeviceCurrentValueStr .1.5.4.1.1.36
-- pdSystem .1.5.5
-- pdSystemCurrent .1.5.5.1
-- pdSystemPower .1.5.5.2
-- fuelSensorStatus .1.6
-- fsStatusTable .1.6.1
-- fsStatusEntry .1.6.1.1
-- fsStatusIndex .1.6.1.1.1
-- fsStatusName .1.6.1.1.2
-- fsStatusDeviceState .1.6.1.1.3
-- fsStatusVolumeValueString .1.6.1.1.4
-- fsStatusVolumePercentLevel .1.6.1.1.7
-- fsStatusVolumeInEventState .1.6.1.1.8
-- fsStatusCombined .1.6.1.1.9
-- wirelessModemStatus .1.7
-- wmsStatus .1.7.1
-- wmsSignal .1.7.2
-- wmsRSSI .1.7.3
-- wmsBER .1.7.4
-- wmsUpdated .1.7.5
-- wmsRegistration .1.7.6
-- wmsLAC .1.7.7
-- wmsCellID .1.7.8
-- wmsIMSI .1.7.9
-- wmsPhnum .1.7.10
-- wmsLocalIP .1.7.11
-- wmsMgfID .1.7.12
-- wmsModelID .1.7.13
-- wmsIMEI .1.7.14
-- wmsRevID .1.7.15
-- wmsNetName .1.7.16
-- wmsGPRSStatus .1.7.17
-- wmsBand .1.7.18
-- wmsChannel .1.7.19
-- wmsCountryCode .1.7.20
-- wmsNetCode .1.7.21
-- wmsPLMNColor .1.7.22
-- wmsBScolor .1.7.23
-- wmsMpRACH .1.7.24
-- wmsMinRxLevel .1.7.25
-- wmsBaseCoeff .1.7.26
-- wmsSIMStatus .1.7.27
-- wmsICCID .1.7.28
-- wmsModemType .1.7.29
-- acPowerMonitorStatus .1.8
-- acpmStatusTable .1.8.1
-- acpmStatusEntry .1.8.1.1
-- acpmsIndex .1.8.1.1.1
-- acpmsName .1.8.1.1.2
-- acpmsAvgVoltageValueStr .1.8.1.1.3
-- acpmsAvgVoltageMinStr .1.8.1.1.4
-- acpmsAvgVoltageMaxStr .1.8.1.1.5
-- acpmsAvgVoltageAvgStr .1.8.1.1.6
-- acpmsAvgVoltageInEventState .1.8.1.1.7
-- acpmsVoltagePhaseAValueStr .1.8.1.1.8
-- acpmsVoltagePhaseBValueStr .1.8.1.1.9
-- acpmsVoltagePhaseCValueStr .1.8.1.1.10
-- acpmsAvgCurrentValueStr .1.8.1.1.11
-- acpmsAvgCurrentMinStr .1.8.1.1.12
-- acpmsAvgCurrentMaxStr .1.8.1.1.13
-- acpmsAvgCurrentAvgStr .1.8.1.1.14
-- acpmsAvgCurrentInEventState .1.8.1.1.15
-- acpmsCurrentPhaseAValueStr .1.8.1.1.16
-- acpmsCurrentPhaseBValueStr .1.8.1.1.17
-- acpmsCurrentPhaseCValueStr .1.8.1.1.18
-- acpmsFreqValueStr .1.8.1.1.19
-- acpmsFreqMinStr .1.8.1.1.20
-- acpmsFreqMaxStr .1.8.1.1.21
-- acpmsFreqAvgStr .1.8.1.1.22
-- acpmsFreqInEventState .1.8.1.1.23
-- acpmsTRPValueStr .1.8.1.1.24
-- acpmsTRPMinStr .1.8.1.1.25
-- acpmsTRPMaxStr .1.8.1.1.26
-- acpmsTRPAvgStr .1.8.1.1.27
-- acpmsTRPInEventState .1.8.1.1.28
-- acpmsRPPhaseAValueStr .1.8.1.1.29
-- acpmsRPPhaseBValueStr .1.8.1.1.30
-- acpmsRPPhaseCValueStr .1.8.1.1.31
-- acpmsCombined .1.8.1.1.32
-- acpmsTPFValueStr .1.8.1.1.33
-- acpmsTPFMinStr .1.8.1.1.34
-- acpmsTPFMaxStr .1.8.1.1.35
-- acpmsTPFAvgStr .1.8.1.1.36
-- acpmsTPFInEventState .1.8.1.1.37
-- acpmsPFPhaseAValueStr .1.8.1.1.38
-- acpmsPFPhaseBValueStr .1.8.1.1.39
-- acpmsPFPhaseCValueStr .1.8.1.1.40
-- acpmsTRcPValueStr .1.8.1.1.41
-- acpmsTRcPMinStr .1.8.1.1.42
-- acpmsTRcPMaxStr .1.8.1.1.43
-- acpmsTRcPAvgStr .1.8.1.1.44
-- acpmsRcPPhaseAValueStr .1.8.1.1.45
-- acpmsRcPPhaseBValueStr .1.8.1.1.46
-- acpmsRcPPhaseCValueStr .1.8.1.1.47
-- acpmsTAPValueStr .1.8.1.1.48
-- acpmsTAPMinStr .1.8.1.1.49
-- acpmsTAPMaxStr .1.8.1.1.50
-- acpmsTAPAvgStr .1.8.1.1.51
-- acpmsAPPhaseAValueStr .1.8.1.1.52
-- acpmsAPPhaseBValueStr .1.8.1.1.53
-- acpmsAPPhaseCValueStr .1.8.1.1.54
-- acpmsTotalEnergyWh .1.8.1.1.55
-- acpmsTotalEnergyVAR .1.8.1.1.56
-- acpmsTotalEnergyVA .1.8.1.1.57
-- batteryMonitorStatus .1.10
-- bmStatusTable .1.10.1
-- bmStatusEntry .1.10.1.1
-- bmsIndex .1.10.1.1.1
-- bmsEnable .1.10.1.1.2
-- bmsName .1.10.1.1.3
-- bmsState .1.10.1.1.4
-- bmsStringState .1.10.1.1.5
-- bmsTempValue .1.10.1.1.6
-- bmsTempValueStr .1.10.1.1.7
-- bmsTempEvent .1.10.1.1.8
-- bmsDiffTempValue .1.10.1.1.9
-- bmsDiffTempValueStr .1.10.1.1.10
-- bmsDiffTempEvent .1.10.1.1.11
-- bmsVoltageValue .1.10.1.1.12
-- bmsVoltageEvent .1.10.1.1.13
-- bmsDiffVoltValue .1.10.1.1.14
-- bmsDiffVoltEvent .1.10.1.1.15
-- bmsCurrentValue .1.10.1.1.16
-- bmsChargingCurrentEvent .1.10.1.1.17
-- bmsDischargingCurrentEvent .1.10.1.1.18
-- bmsChargeLevelValue .1.10.1.1.19
-- bmsChargeLevelEvent .1.10.1.1.20
-- bmsJarHealthValue .1.10.1.1.21
-- bmsJarHealthEvent .1.10.1.1.22
-- bmsCombined .1.10.1.1.23
-- bmJarStatusTable .1.10.2
-- bmJarStatusEntry .1.10.2.1
-- bmjsIndexBM .1.10.2.1.1
-- bmjsIndexJar .1.10.2.1.2
-- bmjsVoltageValue .1.10.2.1.3
-- bmjsTempValue .1.10.2.1.4
-- bmjsAdmittanceValue .1.10.2.1.5
-- bmjsAdmittanceChangeValue .1.10.2.1.6
-- config .2
-- eventSensorBasics .2.1
-- esNumberEventSensors .2.1.1
-- esTable .2.1.2
-- esEntry .2.1.2.1
-- esIndex .2.1.2.1.1
-- esName .2.1.2.1.2
-- esID .2.1.2.1.3
-- esNumberTempSensors .2.1.2.1.4
-- esTempReportingMode .2.1.2.1.5
-- esNumberCCs .2.1.2.1.6
-- esCCReportingMode .2.1.2.1.7
-- esNumberHumidSensors .2.1.2.1.8
-- esHumidReportingMode .2.1.2.1.9
-- esNumberNoiseSensors .2.1.2.1.10
-- esNoiseReportingMode .2.1.2.1.11
-- esNumberAirflowSensors .2.1.2.1.12
-- esAirflowReportingMode .2.1.2.1.13
-- esNumberAnalog .2.1.2.1.14
-- esAnalogReportingMode .2.1.2.1.15
-- esNumberOutputs .2.1.2.1.16
-- esOutputReportingMode .2.1.2.1.17
-- esTempCombinedStatus .2.1.2.1.18
-- esCCCombinedStatusBlock1 .2.1.2.1.19
-- esCCCombinedStatusBlock2 .2.1.2.1.20
-- esCCCombinedStatusBlock3 .2.1.2.1.21
-- esCCCombinedStatusBlock4 .2.1.2.1.22
-- esCCCombinedStatusBlock5 .2.1.2.1.23
-- esCCCombinedStatusBlock6 .2.1.2.1.24
-- esCCCombinedStatusBlock7 .2.1.2.1.25
-- esCCCombinedStatusBlock8 .2.1.2.1.26
-- esHumidCombinedStatus .2.1.2.1.27
-- esAnalogCombinedStatusBlock1 .2.1.2.1.28
-- esAnalogCombinedStatusBlock2 .2.1.2.1.29
-- esAnalogCombinedStatusBlock3 .2.1.2.1.30
-- esAnalogCombinedStatusBlock4 .2.1.2.1.31
-- esAnalogCombinedStatusBlock5 .2.1.2.1.32
-- esAnalogCombinedStatusBlock6 .2.1.2.1.33
-- esOutputCombinedStatusBlock1 .2.1.2.1.34
-- esOutputCombinedStatusBlock2 .2.1.2.1.35
-- esNewSensors .2.1.3
-- eventSensorPointConfig .2.2
-- esPointConfigTempTable .2.2.1
-- esPointConfigTempEntry .2.2.1.1
-- espcTempIndexES .2.2.1.1.1
-- espcTempIndexPoint .2.2.1.1.2
-- espcTempEnable .2.2.1.1.3
-- espcTempScale .2.2.1.1.4
-- espcTempDeadband .2.2.1.1.5
-- espcTempVHighTemp .2.2.1.1.6
-- espcTempVHighActions .2.2.1.1.7
-- espcTempVHighTrapnum .2.2.1.1.8
-- espcTempVHighClass .2.2.1.1.9
-- espcTempHighTemp .2.2.1.1.10
-- espcTempHighActions .2.2.1.1.11
-- espcTempHighTrapnum .2.2.1.1.12
-- espcTempHighClass .2.2.1.1.13
-- espcTempNormalActions .2.2.1.1.14
-- espcTempNormalTrapnum .2.2.1.1.15
-- espcTempNormalClass .2.2.1.1.16
-- espcTempLowTemp .2.2.1.1.17
-- espcTempLowActions .2.2.1.1.18
-- espcTempLowTrapnum .2.2.1.1.19
-- espcTempLowClass .2.2.1.1.20
-- espcTempVLowTemp .2.2.1.1.21
-- espcTempVLowActions .2.2.1.1.22
-- espcTempVLowTrapnum .2.2.1.1.23
-- espcTempVLowClass .2.2.1.1.24
-- esPointConfigCCTable .2.2.2
-- esPointConfigCCEntry .2.2.2.1
-- espcCCIndexES .2.2.2.1.1
-- espcCCIndexPoint .2.2.2.1.2
-- espcCCEnable .2.2.2.1.3
-- espcCCName .2.2.2.1.4
-- espcCCEventState .2.2.2.1.5
-- espcCCThreshold .2.2.2.1.6
-- espcCCEventActions .2.2.2.1.7
-- espcCCEventTrapnum .2.2.2.1.8
-- espcCCEventClass .2.2.2.1.9
-- espcCCNormalActions .2.2.2.1.10
-- espcCCNormalTrapnum .2.2.2.1.11
-- espcCCNormalClass .2.2.2.1.12
-- espcCCAlarmAlias .2.2.2.1.13
-- espcCCNormalAlias .2.2.2.1.14
-- espcCCNormalThreshold .2.2.2.1.15
-- espcCCOverrideGlobalReminder .2.2.2.1.16
-- espcCCReminderInterval .2.2.2.1.17
-- esPointConfigHumidTable .2.2.3
-- esPointConfigHumidEntry .2.2.3.1
-- espcHumidIndexES .2.2.3.1.1
-- espcHumidIndexPoint .2.2.3.1.2
-- espcHumidEnable .2.2.3.1.3
-- espcHumidDeadband .2.2.3.1.4
-- espcHumidVHighHumid .2.2.3.1.5
-- espcHumidVHighActions .2.2.3.1.6
-- espcHumidVHighTrapnum .2.2.3.1.7
-- espcHumidVHighClass .2.2.3.1.8
-- espcHumidHighHumid .2.2.3.1.9
-- espcHumidHighActions .2.2.3.1.10
-- espcHumidHighTrapnum .2.2.3.1.11
-- espcHumidHighClass .2.2.3.1.12
-- espcHumidNormalActions .2.2.3.1.13
-- espcHumidNormalTrapnum .2.2.3.1.14
-- espcHumidNormalClass .2.2.3.1.15
-- espcHumidLowHumid .2.2.3.1.16
-- espcHumidLowActions .2.2.3.1.17
-- espcHumidLowTrapnum .2.2.3.1.18
-- espcHumidLowClass .2.2.3.1.19
-- espcHumidVLowHumid .2.2.3.1.20
-- espcHumidVLowActions .2.2.3.1.21
-- espcHumidVLowTrapnum .2.2.3.1.22
-- espcHumidVLowClass .2.2.3.1.23
-- esPointConfigAITable .2.2.5
-- esPointConfigAIEntry .2.2.5.1
-- espcAIIndexES .2.2.5.1.1
-- espcAIIndexPoint .2.2.5.1.2
-- espcAIEnable .2.2.5.1.3
-- espcAIDeadband .2.2.5.1.5
-- espcAIVhighValue .2.2.5.1.6
-- espcAIVhighActions .2.2.5.1.7
-- espcAIVhighTrapnum .2.2.5.1.8
-- espcAIVhighClass .2.2.5.1.9
-- espcAIHighValue .2.2.5.1.10
-- espcAIHighActions .2.2.5.1.11
-- espcAIHighTrapnum .2.2.5.1.12
-- espcAIHighClass .2.2.5.1.13
-- espcAINormalActions .2.2.5.1.14
-- espcAINormalTrapnum .2.2.5.1.15
-- espcAINormalClass .2.2.5.1.16
-- espcAILowValue .2.2.5.1.17
-- espcAILowActions .2.2.5.1.18
-- espcAILowTrapnum .2.2.5.1.19
-- espcAILowClass .2.2.5.1.20
-- espcAIVlowValue .2.2.5.1.21
-- espcAIVlowActions .2.2.5.1.22
-- espcAIVlowTrapnum .2.2.5.1.23
-- espcAIVlowClass .2.2.5.1.24
-- espcAIConvUnitName .2.2.5.1.25
-- espcAIConvHighValue .2.2.5.1.26
-- espcAIConvHighUnit .2.2.5.1.27
-- espcAIConvLowValue .2.2.5.1.29
-- espcAIConvLowUnit .2.2.5.1.30
-- espcAIDisplayFormat .2.2.5.1.32
-- esPointConfigOutputTable .2.2.6
-- esPointConfigOutputEntry .2.2.6.1
-- espcOutputIndexES .2.2.6.1.1
-- espcOutputIndexPoint .2.2.6.1.2
-- espcOutputEnable .2.2.6.1.3
-- espcOutputActiveState .2.2.6.1.4
-- espcOutputType .2.2.6.1.5
-- espcOutputAliasValue .2.2.6.1.6
-- espcOutputAliasColor .2.2.6.1.7
-- espcOutputActiveAlias .2.2.6.1.10
-- espcOutputActiveColor .2.2.6.1.11
-- espcOutputActiveActions .2.2.6.1.12
-- espcOutputActiveTrapnum .2.2.6.1.13
-- espcOutputActiveClass .2.2.6.1.14
-- espcOutputInactiveAlias .2.2.6.1.20
-- espcOutputInactiveColor .2.2.6.1.21
-- espcOutputInactiveActions .2.2.6.1.22
-- espcOutputInactiveTrapnum .2.2.6.1.23
-- espcOutputInactiveClass .2.2.6.1.24
-- serialPorts .2.3
-- numberPorts .2.3.1
-- portConfigTable .2.3.2
-- portConfigEntry .2.3.2.1
-- portConfigIndex .2.3.2.1.1
-- portConfigBaud .2.3.2.1.2
-- portConfigDataFormat .2.3.2.1.3
-- portConfigId .2.3.2.1.27
-- portConfigMode .2.3.2.1.28
-- portConfigHsk .2.3.2.1.29
-- network .2.4
-- interface .2.4.1
-- ethernet .2.4.1.1
-- ethernet1 .2.4.1.1.1
-- eth1Mode .2.4.1.1.1.1
-- eth1Address .2.4.1.1.1.2
-- eth1SubnetMask .2.4.1.1.1.3
-- eth1Router .2.4.1.1.1.4
-- eth1VLAN .2.4.1.1.1.5
-- eth1VLAN1 .2.4.1.1.1.5.1
-- eth1VLAN1ID .2.4.1.1.1.5.1.1
-- eth1VLAN1Priority .2.4.1.1.1.5.1.2
-- eth1VLAN1Address .2.4.1.1.1.5.1.3
-- eth1VLAN1SubnetMask .2.4.1.1.1.5.1.4
-- eth1VLAN1Router .2.4.1.1.1.5.1.5
-- eth1VLAN2 .2.4.1.1.1.5.2
-- eth1VLAN2ID .2.4.1.1.1.5.2.1
-- eth1VLAN2Priority .2.4.1.1.1.5.2.2
-- eth1VLAN2Address .2.4.1.1.1.5.2.3
-- eth1VLAN2SubnetMask .2.4.1.1.1.5.2.4
-- eth1VLAN2Router .2.4.1.1.1.5.2.5
-- eth1VLAN3 .2.4.1.1.1.5.3
-- eth1VLAN3ID .2.4.1.1.1.5.3.1
-- eth1VLAN3Priority .2.4.1.1.1.5.3.2
-- eth1VLAN3Address .2.4.1.1.1.5.3.3
-- eth1VLAN3SubnetMask .2.4.1.1.1.5.3.4
-- eth1VLAN3Router .2.4.1.1.1.5.3.5
-- eth1VLAN4 .2.4.1.1.1.5.4
-- eth1VLAN4ID .2.4.1.1.1.5.4.1
-- eth1VLAN4Priority .2.4.1.1.1.5.4.2
-- eth1VLAN4Address .2.4.1.1.1.5.4.3
-- eth1VLAN4SubnetMask .2.4.1.1.1.5.4.4
-- eth1VLAN4Router .2.4.1.1.1.5.4.5
-- eth1VLAN5 .2.4.1.1.1.5.5
-- eth1VLAN5ID .2.4.1.1.1.5.5.1
-- eth1VLAN5Priority .2.4.1.1.1.5.5.2
-- eth1VLAN5Address .2.4.1.1.1.5.5.3
-- eth1VLAN5SubnetMask .2.4.1.1.1.5.5.4
-- eth1VLAN5Router .2.4.1.1.1.5.5.5
-- eth1VLAN6 .2.4.1.1.1.5.6
-- eth1VLAN6ID .2.4.1.1.1.5.6.1
-- eth1VLAN6Priority .2.4.1.1.1.5.6.2
-- eth1VLAN6Address .2.4.1.1.1.5.6.3
-- eth1VLAN6SubnetMask .2.4.1.1.1.5.6.4
-- eth1VLAN6Router .2.4.1.1.1.5.6.5
-- eth1MAC .2.4.1.1.1.6
-- eth1IPv6 .2.4.1.1.1.7
-- eth1IPv6Mode .2.4.1.1.1.7.1
-- eth1IPv6Static .2.4.1.1.1.7.2
-- eth1IPv6StaticAddress .2.4.1.1.1.7.2.1
-- eth1IPv6StaticRouter .2.4.1.1.1.7.2.2
-- eth1IPv6Auto .2.4.1.1.1.7.3
-- eth1IPv6AutoAddress1 .2.4.1.1.1.7.3.1
-- eth1IPv6AutoAddress2 .2.4.1.1.1.7.3.2
-- eth1IPv6AutoAddress3 .2.4.1.1.1.7.3.3
-- eth1IPv6AutoAddress4 .2.4.1.1.1.7.3.4
-- eth1IPv6LinkLocalAddress .2.4.1.1.1.7.4
-- ethernet2 .2.4.1.1.2
-- eth2Mode .2.4.1.1.2.1
-- eth2Address .2.4.1.1.2.2
-- eth2SubnetMask .2.4.1.1.2.3
-- eth2Router .2.4.1.1.2.4
-- eth2VLAN .2.4.1.1.2.5
-- eth2VLAN1 .2.4.1.1.2.5.1
-- eth2VLAN1ID .2.4.1.1.2.5.1.1
-- eth2VLAN1Priority .2.4.1.1.2.5.1.2
-- eth2VLAN1Address .2.4.1.1.2.5.1.3
-- eth2VLAN1SubnetMask .2.4.1.1.2.5.1.4
-- eth2VLAN1Router .2.4.1.1.2.5.1.5
-- eth2VLAN2 .2.4.1.1.2.5.2
-- eth2VLAN2ID .2.4.1.1.2.5.2.1
-- eth2VLAN2Priority .2.4.1.1.2.5.2.2
-- eth2VLAN2Address .2.4.1.1.2.5.2.3
-- eth2VLAN2SubnetMask .2.4.1.1.2.5.2.4
-- eth2VLAN2Router .2.4.1.1.2.5.2.5
-- eth2VLAN3 .2.4.1.1.2.5.3
-- eth2VLAN3ID .2.4.1.1.2.5.3.1
-- eth2VLAN3Priority .2.4.1.1.2.5.3.2
-- eth2VLAN3Address .2.4.1.1.2.5.3.3
-- eth2VLAN3SubnetMask .2.4.1.1.2.5.3.4
-- eth2VLAN3Router .2.4.1.1.2.5.3.5
-- eth2VLAN4 .2.4.1.1.2.5.4
-- eth2VLAN4ID .2.4.1.1.2.5.4.1
-- eth2VLAN4Priority .2.4.1.1.2.5.4.2
-- eth2VLAN4Address .2.4.1.1.2.5.4.3
-- eth2VLAN4SubnetMask .2.4.1.1.2.5.4.4
-- eth2VLAN4Router .2.4.1.1.2.5.4.5
-- eth2VLAN5 .2.4.1.1.2.5.5
-- eth2VLAN5ID .2.4.1.1.2.5.5.1
-- eth2VLAN5Priority .2.4.1.1.2.5.5.2
-- eth2VLAN5Address .2.4.1.1.2.5.5.3
-- eth2VLAN5SubnetMask .2.4.1.1.2.5.5.4
-- eth2VLAN5Router .2.4.1.1.2.5.5.5
-- eth2VLAN6 .2.4.1.1.2.5.6
-- eth2VLAN6ID .2.4.1.1.2.5.6.1
-- eth2VLAN6Priority .2.4.1.1.2.5.6.2
-- eth2VLAN6Address .2.4.1.1.2.5.6.3
-- eth2VLAN6SubnetMask .2.4.1.1.2.5.6.4
-- eth2VLAN6Router .2.4.1.1.2.5.6.5
-- eth2MAC .2.4.1.1.2.6
-- eth2IPv6 .2.4.1.1.2.7
-- eth2IPv6Mode .2.4.1.1.2.7.1
-- eth2IPv6Static .2.4.1.1.2.7.2
-- eth2IPv6StaticAddress .2.4.1.1.2.7.2.1
-- eth2IPv6StaticRouter .2.4.1.1.2.7.2.2
-- eth2IPv6Auto .2.4.1.1.2.7.3
-- eth2IPv6AutoAddress1 .2.4.1.1.2.7.3.1
-- eth2IPv6AutoAddress2 .2.4.1.1.2.7.3.2
-- eth2IPv6AutoAddress3 .2.4.1.1.2.7.3.3
-- eth2IPv6AutoAddress4 .2.4.1.1.2.7.3.4
-- eth2IPv6LinkLocalAddress .2.4.1.1.2.7.4
-- defaultRouter .2.4.2
-- dnsTable .2.4.3
-- dnsEntry .2.4.3.1
-- dnsIndex .2.4.3.1.1
-- dnsAddress .2.4.3.1.2
-- hostname .2.4.4
-- hostTable .2.4.5
-- hostEntry .2.4.5.1
-- hostIndex .2.4.5.1.1
-- hostDeclaration .2.4.5.1.2
-- ncpDuplex .2.4.6
-- ncpTimeout .2.4.7
-- snmp .2.4.8
-- snmpAgentEnable .2.4.8.1
-- snmpNotificationTx .2.4.8.7
-- snmpNtfnAttempts .2.4.8.7.1
-- snmpNtfnTimeout .2.4.8.7.2
-- snmpNtfnCycles .2.4.8.7.3
-- snmpNtfnSnooze .2.4.8.7.4
-- snmpProxy .2.4.8.8
-- snmpProxyTable .2.4.8.8.1
-- snmpProxyEntry .2.4.8.8.1.1
-- snmpProxyIndex .2.4.8.8.1.1.1
-- snmpProxyEgressOIDBranch .2.4.8.8.1.1.2
-- snmpProxyIP .2.4.8.8.1.1.3
-- snmpProxyPort .2.4.8.8.1.1.4
-- snmpProxyIngressOIDBranch .2.4.8.8.1.1.5
-- snmpProxyName .2.4.8.8.1.1.6
-- snmpPoll .2.4.8.9
-- snmpPMode .2.4.8.9.1
-- snmpPRequestTable .2.4.8.9.4
-- snmpPRequestEntry .2.4.8.9.4.1
-- snmpPRequestIndex .2.4.8.9.4.1.1
-- snmpPRequestDescription .2.4.8.9.4.1.2
-- snmpPRequestAgent .2.4.8.9.4.1.3
-- snmpPRequestReadcom .2.4.8.9.4.1.4
-- snmpPRequestOID .2.4.8.9.4.1.5
-- snmpPRequestPeriod .2.4.8.9.4.1.6
-- snmpPRequestResultStatus .2.4.8.9.4.1.10
-- snmpPRequestResultValue .2.4.8.9.4.1.11
-- snmpPRequestResultTime .2.4.8.9.4.1.12
-- snmpPRequestResultType .2.4.8.9.4.1.13
-- ftpPush .2.4.9
-- ftpPushEnable .2.4.9.1
-- ftpPushServer .2.4.9.2
-- ftpPushAccount .2.4.9.5
-- ftpPushDirectory .2.4.9.6
-- ftpPushperiod .2.4.9.7
-- ftpPushPushFileTable .2.4.9.8
-- ftpPushPushFileEntry .2.4.9.8.1
-- ftpPushPushFileIndex .2.4.9.8.1.1
-- ftpPushPushFile .2.4.9.8.1.2
-- ftpPushPushAudit .2.4.9.9
-- ftpPushPushAlarms .2.4.9.10
-- ftpPushRemoteFileTable .2.4.9.11
-- ftpPushRemoteFileEntry .2.4.9.11.1
-- ftpPushRemoteFileIndex .2.4.9.11.1.1
-- ftpPushRemoteFileName .2.4.9.11.1.2
-- ftpPushRemoteAlarmName .2.4.9.12
-- ftpPushPassive .2.4.9.13
-- ftpPushIncludeDate .2.4.9.14
-- ftpPushIncludeTime .2.4.9.15
-- ftpPushIncludeSeq .2.4.9.16
-- ftpPushPermissions .2.4.9.17
-- routing .2.4.11
-- ethRoutingEnable .2.4.11.2
-- ethRoutingNATEnable .2.4.11.3
-- netSecurity .2.4.12
-- ipRestriction .2.4.12.1
-- ipRestrictionTable .2.4.12.1.1
-- ipRestrictionEntry .2.4.12.1.1.1
-- ipRestrictionIndex .2.4.12.1.1.1.1
-- ipRestrictionEnable .2.4.12.1.1.1.2
-- ipRestrictionMask .2.4.12.1.1.1.3
-- trap .2.4.14
-- trapInclude .2.4.14.1
-- trapIncludeDateTime .2.4.14.1.1
-- trapIncludeSiteName .2.4.14.1.2
-- trapIncludeSensorID .2.4.14.1.3
-- trapIncludeUDName .2.4.14.1.4
-- trapIncludeUDState .2.4.14.1.5
-- trapIncludeSourceAddress .2.4.14.1.6
-- trapAuthFailEnable .2.4.14.2
-- wireless .2.4.16
-- wirelessMode .2.4.16.1
-- wirelessAPN .2.4.16.2
-- wirelessIdleTimeout .2.4.16.3
-- wirelessPIN .2.4.16.5
-- wirelessDRE .2.4.16.9
-- wirelessPPPUsername .2.4.16.10
-- wirelessFirewall .2.4.16.11
-- wirelessKeepaliveThreshold .2.4.16.12
-- wirelessPPPDebug .2.4.16.13
-- wirelessConnectivity .2.4.16.20
-- wirelessConnEnable .2.4.16.20.1
-- wirelessConnCheckInterval .2.4.16.20.2
-- wirelessConnFailThreshold .2.4.16.20.3
-- wirelessConnIP1 .2.4.16.20.10
-- wirelessConnIP2 .2.4.16.20.11
-- email .2.4.17
-- emailServer .2.4.17.1
-- emailDomain .2.4.17.2
-- emailAuthEnable .2.4.17.3
-- netAdvanced .2.4.18
-- arpFilter .2.4.18.1
-- web .2.4.19
-- webEnable .2.4.19.1
-- webPort .2.4.19.1
-- webTimeout .2.4.19.1
-- ipv6 .2.4.21
-- ipv6DefaultRouter .2.4.21.1
-- cpe .2.4.22
-- cpeTable .2.4.22.1
-- cpeEntry .2.4.22.1.1
-- cpeIndex .2.4.22.1.1.1
-- cpeHost .2.4.22.1.1.2
-- cpeName .2.4.22.1.1.3
-- cpeDescription .2.4.22.1.1.4
-- cpeKeepalive .2.4.22.1.1.5
-- cpeThreshold .2.4.22.1.1.6
-- cpeEventReminderInterval .2.4.22.1.1.7
-- cpeKeepaliveTicks .2.4.22.1.1.20
-- cpePingSize .2.4.22.1.1.21
-- cpeInfoReset .2.4.22.1.1.30
-- cpeInfoNumReq .2.4.22.1.1.31
-- cpeInfoNumGoodResp .2.4.22.1.1.32
-- cpeInfoNumBadResp .2.4.22.1.1.33
-- cpeInfoNumLostResp .2.4.22.1.1.34
-- cpeInfoPercentLoss .2.4.22.1.1.35
-- cpeInfoPercentBad .2.4.22.1.1.36
-- time .2.8
-- clock .2.8.1
-- console .2.10
-- consoleDuplex .2.10.1
-- consoleTimeout .2.10.2
-- consoleConfirm .2.10.7
-- unitSecurity .2.11
-- secCore .2.11.1
-- scShowPasswordPrompt .2.11.1.1
-- scConsoleLoginRequired .2.11.1.2
-- scTelnetLoginRequired .2.11.1.4
-- scTelnetPTLoginRequired .2.11.1.5
-- scAuthMode .2.11.1.7
-- scRightsGroup .2.11.1.8
-- scSecret .2.11.1.9
-- secUserTable .2.11.2
-- secUserEntry .2.11.2.1
-- secUserIndex .2.11.2.1.1
-- secUserEnable .2.11.2.1.2
-- secUserConnectVia .2.11.2.1.5
-- secUserLoginTo .2.11.2.1.6
-- secUserAccessFile .2.11.2.1.7
-- secUserPTEscapeTo .2.11.2.1.9
-- secUserRights .2.11.2.1.11
-- secUserEventsReadAccess .2.11.2.1.13
-- secUserAuditReadAccess .2.11.2.1.14
-- secUserEventsWriteAccess .2.11.2.1.16
-- secUserAuditWriteAccess .2.11.2.1.17
-- secUserExpiration .2.11.2.1.18
-- secUserChallengeConsoleMode .2.11.2.1.24
-- secUserChallengeExpiration .2.11.2.1.27
-- secFactory .2.11.3
-- sfEnable .2.11.3.1
-- sfSecret .2.11.3.2
-- event .2.12
-- evCore .2.12.1
-- evClassNameTable .2.12.1.1
-- evClassNameEntry .2.12.1.1.1
-- evClassNameIndex .2.12.1.1.1.1
-- evClassName .2.12.1.1.1.2
-- evReminderInterval .2.12.1.2
-- evLog .2.12.1.3
-- evLogEnable .2.12.1.3.1
-- evLogStoreAlarm .2.12.1.3.2
-- evLogMaxSize .2.12.1.3.3
-- evLogStoreSensor .2.12.1.3.4
-- evLogTimeStampAlarms .2.12.1.3.5
-- evLogPrependName .2.12.1.3.6
-- evMgmt .2.12.1.4
-- evMgmtReprocess .2.12.1.4.3
-- evSched1 .2.12.5
-- evSched1Enable .2.12.5.1
-- evSched1Actions .2.12.5.2
-- evSched1Message .2.12.5.3
-- evSched1TrapNum .2.12.5.4
-- evSched1Class .2.12.5.5
-- evSched1Sunday .2.12.5.6
-- evSched1Monday .2.12.5.7
-- evSched1Tuesday .2.12.5.8
-- evSched1Wednesday .2.12.5.9
-- evSched1Thursday .2.12.5.10
-- evSched1Friday .2.12.5.11
-- evSched1Saturday .2.12.5.12
-- evSched1Exclusions .2.12.5.13
-- evSched2 .2.12.6
-- evSched2Enable .2.12.6.1
-- evSched2Actions .2.12.6.2
-- evSched2Message .2.12.6.3
-- evSched2TrapNum .2.12.6.4
-- evSched2Class .2.12.6.5
-- evSched2Sunday .2.12.6.6
-- evSched2Monday .2.12.6.7
-- evSched2Tuesday .2.12.6.8
-- evSched2Wednesday .2.12.6.9
-- evSched2Thursday .2.12.6.10
-- evSched2Friday .2.12.6.11
-- evSched2Saturday .2.12.6.12
-- evSched2Exclusions .2.12.6.13
-- evShskLowTable .2.12.7
-- evShskLowEntry .2.12.7.1
-- evShskLowIndex .2.12.7.1.1
-- evShskLowEnable .2.12.7.1.2
-- evShskLowActions .2.12.7.1.3
-- evShskLowMessage .2.12.7.1.4
-- evShskLowClass .2.12.7.1.5
-- evShskLowTrapNum .2.12.7.1.6
-- evShskHighTable .2.12.8
-- evShskHighEntry .2.12.8.1
-- evShskHighIndex .2.12.8.1.1
-- evShskHighEnable .2.12.8.1.2
-- evShskHighActions .2.12.8.1.3
-- evShskHighMessage .2.12.8.1.4
-- evShskHighClass .2.12.8.1.5
-- evShskHighTrapNum .2.12.8.1.6
-- evNoSensor .2.12.9
-- evNoSensorTimeout .2.12.9.1
-- evNoSensorActions .2.12.9.2
-- evNoSensorTrapNum .2.12.9.3
-- evNoSensorClass .2.12.9.4
-- fuelSensor .2.12.11
-- fuelSensorGeneralTable .2.12.11.1
-- fsGenEntry .2.12.11.1.1
-- fsGenIndex .2.12.11.1.1.1
-- fsGenName .2.12.11.1.1.2
-- fsGenSensorType .2.12.11.1.1.3
-- fsGenDistanceUnit .2.12.11.1.1.4
-- fsGenRawValueTop .2.12.11.1.1.5
-- fsGenTopOffset .2.12.11.1.1.6
-- fsGenRawValueBottom .2.12.11.1.1.7
-- fsGenBottomOffset .2.12.11.1.1.8
-- fsGenInputES .2.12.11.1.1.9
-- fsGenInputPoint .2.12.11.1.1.10
-- fsGenFilterAveraging .2.12.11.1.1.11
-- fsGenSysrepEnable .2.12.11.1.1.12
-- fsGenSysrepThreshold .2.12.11.1.1.13
-- fsGenSysrepLimit .2.12.11.1.1.14
-- fsGenSysrepPackage .2.12.11.1.1.15
-- fsGenSysrepType .2.12.11.1.1.16
-- fsGenEnable .2.12.11.1.1.17
-- fuelSensorTankTable .2.12.11.2
-- fsTankEntry .2.12.11.2.1
-- fsTankIndex .2.12.11.2.1.1
-- fsTankHeight .2.12.11.2.1.2
-- fsTankDimA .2.12.11.2.1.3
-- fsTankDimB .2.12.11.2.1.4
-- fsTankVolume .2.12.11.2.1.5
-- fsTankVolumeUnit .2.12.11.2.1.6
-- fsTankShape .2.12.11.2.1.7
-- fuelSensorCustomTankTable .2.12.11.3
-- fsCustomTankEntry .2.12.11.3.1
-- fsCustomTankIndexFS .2.12.11.3.1.1
-- fsCustomTankIndexDatum .2.12.11.3.1.2
-- fsCustomTankHeight .2.12.11.3.1.3
-- fsCustomTankVolume .2.12.11.3.1.4
-- fuelSensorVolumeTable .2.12.11.4
-- fsVolumeEntry .2.12.11.4.1
-- fsVolumeIndex .2.12.11.4.1.1
-- fsVolumeEnable .2.12.11.4.1.2
-- fsVolumeDeadband .2.12.11.4.1.3
-- fsVolumeVHighValue .2.12.11.4.1.4
-- fsVolumeVHighActions .2.12.11.4.1.5
-- fsVolumeVHighTrapNum .2.12.11.4.1.6
-- fsVolumeVHighClass .2.12.11.4.1.7
-- fsVolumeHighValue .2.12.11.4.1.8
-- fsVolumeHighActions .2.12.11.4.1.9
-- fsVolumeHighTrapNum .2.12.11.4.1.10
-- fsVolumeHighClass .2.12.11.4.1.11
-- fsVolumeNormalActions .2.12.11.4.1.12
-- fsVolumeNormalTrapNum .2.12.11.4.1.13
-- fsVolumeNormalClass .2.12.11.4.1.14
-- fsVolumeLowValue .2.12.11.4.1.15
-- fsVolumeLowActions .2.12.11.4.1.16
-- fsVolumeLowTrapNum .2.12.11.4.1.17
-- fsVolumeLowClass .2.12.11.4.1.18
-- fsVolumeVLowValue .2.12.11.4.1.19
-- fsVolumeVLowActions .2.12.11.4.1.20
-- fsVolumeVLowTrapNum .2.12.11.4.1.21
-- fsVolumeVLowClass .2.12.11.4.1.22
-- fuelSensorDisconnectTable .2.12.11.5
-- fsDiscEntry .2.12.11.5.1
-- fsDiscIndex .2.12.11.5.1.1
-- fsDiscEnable .2.12.11.5.1.2
-- fsDiscHighValue .2.12.11.5.1.3
-- fsDiscLowValue .2.12.11.5.1.4
-- fsDiscActions .2.12.11.5.1.5
-- fsDiscTrapNum .2.12.11.5.1.6
-- fsDiscClass .2.12.11.5.1.7
-- fsDiscNormalActions .2.12.11.5.1.8
-- fsDiscNormalTrapNum .2.12.11.5.1.9
-- fsDiscNormalClass .2.12.11.5.1.10
-- fuelSensorSuddenChangeTable .2.12.11.6
-- fsSuddenChangeEntry .2.12.11.6.1
-- fsSuddenChangeIndex .2.12.11.6.1.1
-- fsSuddenChangeEnable .2.12.11.6.1.2
-- fsSuddenChangeTime .2.12.11.6.1.3
-- fsSuddenChangeAmplitude .2.12.11.6.1.4
-- fsSuddenChangeActions .2.12.11.6.1.5
-- fsSuddenChangeTrapNum .2.12.11.6.1.6
-- fsSuddenChangeClass .2.12.11.6.1.7
-- fuelSensorSlowChangeTable .2.12.11.7
-- fuelSensorSlowChangeEntry .2.12.11.7.1
-- fsSlowChangeIndex .2.12.11.7.1.1
-- fsSlowChangeEnable .2.12.11.7.1.2
-- fsSlowChangeTime .2.12.11.7.1.3
-- fsSlowChangeAmplitude .2.12.11.7.1.4
-- fsSlowChangeActions .2.12.11.7.1.5
-- fsSlowChangeTrapNum .2.12.11.7.1.6
-- fsSlowChangeClass .2.12.11.7.1.7
-- fuelSensorLevelsAutoAdjustTable .2.12.11.8
-- fsLAAEntry .2.12.11.8.1
-- fsLAAIndex .2.12.11.8.1.1
-- fsLAAEnable .2.12.11.8.1.2
-- fsLAAEventEnable .2.12.11.8.1.3
-- fsLAAEventThreshold .2.12.11.8.1.4
-- fsLAAEventActions .2.12.11.8.1.5
-- fsLAAEventClass .2.12.11.8.1.6
-- fsLAAEventTrapNum .2.12.11.8.1.7
-- acPowerMonitor .2.12.12
-- acpmGeneralTable .2.12.12.1
-- acpmGenEntry .2.12.12.1.1
-- acpmGenIndex .2.12.12.1.1.1
-- acpmGenDevice .2.12.12.1.1.2
-- acpmGenName .2.12.12.1.1.3
-- acpmGenAddress .2.12.12.1.1.4
-- acpmGenPtRatio .2.12.12.1.1.5
-- acpmGenCtRatio .2.12.12.1.1.6
-- acpmGenPowerType .2.12.12.1.1.7
-- acpmGenSysrepPackage .2.12.12.1.1.8
-- acpmGenSysrepType .2.12.12.1.1.9
-- acpmGenEnable .2.12.12.1.1.10
-- acpmAvgVoltageTable .2.12.12.2
-- acpmAvgVoltageEntry .2.12.12.2.1
-- acpmAvgVoltageIndex .2.12.12.2.1.1
-- acpmAvgVoltageEnable .2.12.12.2.1.2
-- acpmAvgVoltageDeadband .2.12.12.2.1.3
-- acpmAvgVoltageVHighValue .2.12.12.2.1.4
-- acpmAvgVoltageVHighActions .2.12.12.2.1.5
-- acpmAvgVoltageVHighTrapNum .2.12.12.2.1.6
-- acpmAvgVoltageVHighClass .2.12.12.2.1.7
-- acpmAvgVoltageHighValue .2.12.12.2.1.8
-- acpmAvgVoltageHighActions .2.12.12.2.1.9
-- acpmAvgVoltageHighTrapNum .2.12.12.2.1.10
-- acpmAvgVoltageHighClass .2.12.12.2.1.11
-- acpmAvgVoltageNormalActions .2.12.12.2.1.12
-- acpmAvgVoltageNormalTrapNum .2.12.12.2.1.13
-- acpmAvgVoltageNormalClass .2.12.12.2.1.14
-- acpmAvgVoltageLowValue .2.12.12.2.1.15
-- acpmAvgVoltageLowActions .2.12.12.2.1.16
-- acpmAvgVoltageLowTrapNum .2.12.12.2.1.17
-- acpmAvgVoltageLowClass .2.12.12.2.1.18
-- acpmAvgVoltageVLowValue .2.12.12.2.1.19
-- acpmAvgVoltageVLowActions .2.12.12.2.1.20
-- acpmAvgVoltageVLowTrapNum .2.12.12.2.1.21
-- acpmAvgVoltageVLowClass .2.12.12.2.1.22
-- acpmAvgVoltageSysrepEnable .2.12.12.2.1.23
-- acpmAvgVoltageSysrepThreshold .2.12.12.2.1.24
-- acpmAvgVoltageSysrepLimit .2.12.12.2.1.25
-- acpmAvgCurrentTable .2.12.12.3
-- acpmAvgCurrentEntry .2.12.12.3.1
-- acpmAvgCurrentIndex .2.12.12.3.1.1
-- acpmAvgCurrentEnable .2.12.12.3.1.2
-- acpmAvgCurrentDeadband .2.12.12.3.1.3
-- acpmAvgCurrentVHighValue .2.12.12.3.1.4
-- acpmAvgCurrentVHighActions .2.12.12.3.1.5
-- acpmAvgCurrentVHighTrapNum .2.12.12.3.1.6
-- acpmAvgCurrentVHighClass .2.12.12.3.1.7
-- acpmAvgCurrentHighValue .2.12.12.3.1.8
-- acpmAvgCurrentHighActions .2.12.12.3.1.9
-- acpmAvgCurrentHighTrapNum .2.12.12.3.1.10
-- acpmAvgCurrentHighClass .2.12.12.3.1.11
-- acpmAvgCurrentNormalActions .2.12.12.3.1.12
-- acpmAvgCurrentNormalTrapNum .2.12.12.3.1.13
-- acpmAvgCurrentNormalClass .2.12.12.3.1.14
-- acpmAvgCurrentLowValue .2.12.12.3.1.15
-- acpmAvgCurrentLowActions .2.12.12.3.1.16
-- acpmAvgCurrentLowTrapNum .2.12.12.3.1.17
-- acpmAvgCurrentLowClass .2.12.12.3.1.18
-- acpmAvgCurrentVLowValue .2.12.12.3.1.19
-- acpmAvgCurrentVLowActions .2.12.12.3.1.20
-- acpmAvgCurrentVLowTrapNum .2.12.12.3.1.21
-- acpmAvgCurrentVLowClass .2.12.12.3.1.22
-- acpmAvgCurrentSysrepEnable .2.12.12.3.1.23
-- acpmAvgCurrentSysrepThreshold .2.12.12.3.1.24
-- acpmAvgCurrentSysrepLimit .2.12.12.3.1.25
-- acpmFreqTable .2.12.12.4
-- acpmFreqEntry .2.12.12.4.1
-- acpmFreqIndex .2.12.12.4.1.1
-- acpmFreqEnable .2.12.12.4.1.2
-- acpmFreqDeadband .2.12.12.4.1.3
-- acpmFreqVHighValue .2.12.12.4.1.4
-- acpmFreqVHighActions .2.12.12.4.1.5
-- acpmFreqVHighTrapNum .2.12.12.4.1.6
-- acpmFreqVHighClass .2.12.12.4.1.7
-- acpmFreqHighValue .2.12.12.4.1.8
-- acpmFreqHighActions .2.12.12.4.1.9
-- acpmFreqHighTrapNum .2.12.12.4.1.10
-- acpmFreqHighClass .2.12.12.4.1.11
-- acpmFreqNormalActions .2.12.12.4.1.12
-- acpmFreqNormalTrapNum .2.12.12.4.1.13
-- acpmFreqNormalClass .2.12.12.4.1.14
-- acpmFreqLowValue .2.12.12.4.1.15
-- acpmFreqLowActions .2.12.12.4.1.16
-- acpmFreqLowTrapNum .2.12.12.4.1.17
-- acpmFreqLowClass .2.12.12.4.1.18
-- acpmFreqVLowValue .2.12.12.4.1.19
-- acpmFreqVLowActions .2.12.12.4.1.20
-- acpmFreqVLowTrapNum .2.12.12.4.1.21
-- acpmFreqVLowClass .2.12.12.4.1.22
-- acpmFreqSysrepEnable .2.12.12.4.1.23
-- acpmFreqSysrepThreshold .2.12.12.4.1.24
-- acpmFreqSysrepLimit .2.12.12.4.1.25
-- acpmTotalRealPowerTable .2.12.12.5
-- acpmTRPEntry .2.12.12.5.1
-- acpmTRPIndex .2.12.12.5.1.1
-- acpmTRPEnable .2.12.12.5.1.2
-- acpmTRPDeadband .2.12.12.5.1.3
-- acpmTRPVHighValue .2.12.12.5.1.4
-- acpmTRPVHighActions .2.12.12.5.1.5
-- acpmTRPVHighTrapNum .2.12.12.5.1.6
-- acpmTRPVHighClass .2.12.12.5.1.7
-- acpmTRPHighValue .2.12.12.5.1.8
-- acpmTRPHighActions .2.12.12.5.1.9
-- acpmTRPHighTrapNum .2.12.12.5.1.10
-- acpmTRPHighClass .2.12.12.5.1.11
-- acpmTRPNormalActions .2.12.12.5.1.12
-- acpmTRPNormalTrapNum .2.12.12.5.1.13
-- acpmTRPNormalClass .2.12.12.5.1.14
-- acpmTRPLowValue .2.12.12.5.1.15
-- acpmTRPLowActions .2.12.12.5.1.16
-- acpmTRPLowTrapNum .2.12.12.5.1.17
-- acpmTRPLowClass .2.12.12.5.1.18
-- acpmTRPVLowValue .2.12.12.5.1.19
-- acpmTRPVLowActions .2.12.12.5.1.20
-- acpmTRPVLowTrapNum .2.12.12.5.1.21
-- acpmTRPVLowClass .2.12.12.5.1.22
-- acpmTRPSysrepEnable .2.12.12.5.1.23
-- acpmTRPSysrepThreshold .2.12.12.5.1.24
-- acpmTRPSysrepLimit .2.12.12.5.1.25
-- acpmDisconnectTable .2.12.12.6
-- acpmDisconnectEntry .2.12.12.6.1
-- acpmDisconnectIndex .2.12.12.6.1.1
-- acpmDisconnectEnable .2.12.12.6.1.2
-- acpmDisconnectActions .2.12.12.6.1.3
-- acpmDisconnectTrapNum .2.12.12.6.1.4
-- acpmDisconnectClass .2.12.12.6.1.5
-- acpmDisconnectNormalActions .2.12.12.6.1.6
-- acpmDisconnectNormalTrapNum .2.12.12.6.1.7
-- acpmDisconnectNormalClass .2.12.12.6.1.8
-- batteryMonitor .2.12.14
-- batteryMonitorGeneralTable .2.12.14.1
-- bmGenEntry .2.12.14.1.1
-- bmGenIndex .2.12.14.1.1.1
-- bmGenEnable .2.12.14.1.1.2
-- bmGenName .2.12.14.1.1.3
-- bmGenBatteryQuantity .2.12.14.1.1.4
-- bmGenBatteryCapacity .2.12.14.1.1.5
-- bmGenBatteryNominalVoltage .2.12.14.1.1.6
-- bmGenSysrepPackage .2.12.14.1.1.7
-- bmGenSysrepType .2.12.14.1.1.8
-- batteryMonitorDeviceTable .2.12.14.2
-- bmDeviceEntry .2.12.14.2.1
-- bmDeviceIndex .2.12.14.2.1.1
-- bmDeviceType .2.12.14.2.1.2
-- bmDeviceES .2.12.14.2.1.3
-- bmDeviceIP .2.12.14.2.1.4
-- bmDeviceReadcom .2.12.14.2.1.5
-- bmDeviceInputString .2.12.14.2.1.6
-- bmDeviceCTSize .2.12.14.2.1.7
-- batteryMonitorTempTable .2.12.14.3
-- bmTempEntry .2.12.14.3.1
-- bmTempIndex .2.12.14.3.1.1
-- bmTempEnable .2.12.14.3.1.2
-- bmTempDeadband .2.12.14.3.1.3
-- bmTempScale .2.12.14.3.1.4
-- bmTempHighValue .2.12.14.3.1.5
-- bmTempHighActions .2.12.14.3.1.6
-- bmTempHighTrapNum .2.12.14.3.1.7
-- bmTempHighClass .2.12.14.3.1.8
-- bmTempNormalActions .2.12.14.3.1.9
-- bmTempNormalTrapNum .2.12.14.3.1.10
-- bmTempNormalClass .2.12.14.3.1.11
-- bmTempLowValue .2.12.14.3.1.12
-- bmTempLowActions .2.12.14.3.1.13
-- bmTempLowTrapNum .2.12.14.3.1.14
-- bmTempLowClass .2.12.14.3.1.15
-- bmTempSysrepEnable .2.12.14.3.1.16
-- bmTempSysrepThreshold .2.12.14.3.1.17
-- bmTempSysrepLimit .2.12.14.3.1.18
-- batteryMonitorDiffTempTable .2.12.14.4
-- bmDiffTempEntry .2.12.14.4.1
-- bmDiffTempIndex .2.12.14.4.1.1
-- bmDiffTempEnable .2.12.14.4.1.2
-- bmDiffTempDeadband .2.12.14.4.1.3
-- bmDiffTempVHighValue .2.12.14.4.1.4
-- bmDiffTempVHighActions .2.12.14.4.1.5
-- bmDiffTempVHighTrapNum .2.12.14.4.1.6
-- bmDiffTempVHighClass .2.12.14.4.1.7
-- bmDiffTempHighValue .2.12.14.4.1.8
-- bmDiffTempHighActions .2.12.14.4.1.9
-- bmDiffTempHighTrapNum .2.12.14.4.1.10
-- bmDiffTempHighClass .2.12.14.4.1.11
-- bmDiffTempNormalActions .2.12.14.4.1.12
-- bmDiffTempNormalTrapNum .2.12.14.4.1.13
-- bmDiffTempNormalClass .2.12.14.4.1.14
-- bmDiffTempSysrepEnable .2.12.14.4.1.15
-- bmDiffTempSysrepThreshold .2.12.14.4.1.16
-- bmDiffTempSysrepLimit .2.12.14.4.1.17
-- batteryMonitorVoltageTable .2.12.14.5
-- bmVoltageEntry .2.12.14.5.1
-- bmVoltageIndex .2.12.14.5.1.1
-- bmVoltageEnable .2.12.14.5.1.2
-- bmVoltageDeadband .2.12.14.5.1.3
-- bmVoltageVHighValue .2.12.14.5.1.4
-- bmVoltageVHighActions .2.12.14.5.1.5
-- bmVoltageVHighTrapNum .2.12.14.5.1.6
-- bmVoltageVHighClass .2.12.14.5.1.7
-- bmVoltageHighValue .2.12.14.5.1.8
-- bmVoltageHighActions .2.12.14.5.1.9
-- bmVoltageHighTrapNum .2.12.14.5.1.10
-- bmVoltageHighClass .2.12.14.5.1.11
-- bmVoltageNormalActions .2.12.14.5.1.12
-- bmVoltageNormalTrapNum .2.12.14.5.1.13
-- bmVoltageNormalClass .2.12.14.5.1.14
-- bmVoltageLowValue .2.12.14.5.1.15
-- bmVoltageLowActions .2.12.14.5.1.16
-- bmVoltageLowTrapNum .2.12.14.5.1.17
-- bmVoltageLowClass .2.12.14.5.1.18
-- bmVoltageVLowValue .2.12.14.5.1.19
-- bmVoltageVLowActions .2.12.14.5.1.20
-- bmVoltageVLowTrapNum .2.12.14.5.1.21
-- bmVoltageVLowClass .2.12.14.5.1.22
-- bmVoltageSysrepEnable .2.12.14.5.1.23
-- bmVoltageSysrepThreshold .2.12.14.5.1.24
-- bmVoltageSysrepLimit .2.12.14.5.1.25
-- batteryMonitorDiffVoltTable .2.12.14.6
-- bmDiffVoltEntry .2.12.14.6.1
-- bmDiffVoltIndex .2.12.14.6.1.1
-- bmDiffVoltEnable .2.12.14.6.1.2
-- bmDiffVoltDeadband .2.12.14.6.1.3
-- bmDiffVoltVHighValue .2.12.14.6.1.4
-- bmDiffVoltVHighActions .2.12.14.6.1.5
-- bmDiffVoltVHighTrapNum .2.12.14.6.1.6
-- bmDiffVoltVHighClass .2.12.14.6.1.7
-- bmDiffVoltHighValue .2.12.14.6.1.8
-- bmDiffVoltHighActions .2.12.14.6.1.9
-- bmDiffVoltHighTrapNum .2.12.14.6.1.10
-- bmDiffVoltHighClass .2.12.14.6.1.11
-- bmDiffVoltNormalActions .2.12.14.6.1.12
-- bmDiffVoltNormalTrapNum .2.12.14.6.1.13
-- bmDiffVoltNormalClass .2.12.14.6.1.14
-- bmDiffVoltSysrepEnable .2.12.14.6.1.15
-- bmDiffVoltSysrepThreshold .2.12.14.6.1.16
-- bmDiffVoltSysrepLimit .2.12.14.6.1.17
-- batteryMonitorChargingCurrentTable .2.12.14.7
-- bmChargingCurrentEntry .2.12.14.7.1
-- bmChargingCurrentIndex .2.12.14.7.1.1
-- bmChargingCurrentEnable .2.12.14.7.1.2
-- bmChargingCurrentDeadband .2.12.14.7.1.3
-- bmChargingCurrentVHighValue .2.12.14.7.1.4
-- bmChargingCurrentVHighActions .2.12.14.7.1.5
-- bmChargingCurrentVHighTrapNum .2.12.14.7.1.6
-- bmChargingCurrentVHighClass .2.12.14.7.1.7
-- bmChargingCurrentHighValue .2.12.14.7.1.8
-- bmChargingCurrentHighActions .2.12.14.7.1.9
-- bmChargingCurrentHighTrapNum .2.12.14.7.1.10
-- bmChargingCurrentHighClass .2.12.14.7.1.11
-- bmChargingCurrentNormalActions .2.12.14.7.1.12
-- bmChargingCurrentNormalTrapNum .2.12.14.7.1.13
-- bmChargingCurrentNormalClass .2.12.14.7.1.14
-- bmChargingCurrentSysrepEnable .2.12.14.7.1.15
-- bmChargingCurrentSysrepThreshold .2.12.14.7.1.16
-- bmChargingCurrentSysrepLimit .2.12.14.7.1.17
-- batteryMonitorDischargingCurrentTable .2.12.14.8
-- bmDischargingCurrentEntry .2.12.14.8.1
-- bmDischargingCurrentIndex .2.12.14.8.1.1
-- bmDischargingCurrentEnable .2.12.14.8.1.2
-- bmDischargingCurrentDeadband .2.12.14.8.1.3
-- bmDischargingCurrentVHighValue .2.12.14.8.1.4
-- bmDischargingCurrentVHighActions .2.12.14.8.1.5
-- bmDischargingCurrentVHighTrapNum .2.12.14.8.1.6
-- bmDischargingCurrentVHighClass .2.12.14.8.1.7
-- bmDischargingCurrentHighValue .2.12.14.8.1.8
-- bmDischargingCurrentHighActions .2.12.14.8.1.9
-- bmDischargingCurrentHighTrapNum .2.12.14.8.1.10
-- bmDischargingCurrentHighClass .2.12.14.8.1.11
-- bmDischargingCurrentNormalActions .2.12.14.8.1.12
-- bmDischargingCurrentNormalTrapNum .2.12.14.8.1.13
-- bmDischargingCurrentNormalClass .2.12.14.8.1.14
-- bmDischargingCurrentSysrepEnable .2.12.14.8.1.15
-- bmDischargingCurrentSysrepThreshold .2.12.14.8.1.16
-- bmDischargingCurrentSysrepLimit .2.12.14.8.1.17
-- batteryMonitorChargeLevelTable .2.12.14.9
-- bmChargeLevelEntry .2.12.14.9.1
-- bmChargeLevelIndex .2.12.14.9.1.1
-- bmChargeLevelEnable .2.12.14.9.1.2
-- bmChargeLevelNormalActions .2.12.14.9.1.3
-- bmChargeLevelNormalTrapNum .2.12.14.9.1.4
-- bmChargeLevelNormalClass .2.12.14.9.1.5
-- bmChargeLevelLowActions .2.12.14.9.1.6
-- bmChargeLevelLowTrapNum .2.12.14.9.1.7
-- bmChargeLevelLowClass .2.12.14.9.1.8
-- bmChargeLevelVLowActions .2.12.14.9.1.9
-- bmChargeLevelVLowTrapNum .2.12.14.9.1.10
-- bmChargeLevelVLowClass .2.12.14.9.1.11
-- bmChargeLevelSysrepEnable .2.12.14.9.1.12
-- batteryMonitorJarHealthTable .2.12.14.10
-- bmJarHealthEntry .2.12.14.10.1
-- bmJarHealthIndex .2.12.14.10.1.1
-- bmJarHealthEnable .2.12.14.10.1.2
-- bmJarHealthNormalActions .2.12.14.10.1.3
-- bmJarHealthNormalTrapNum .2.12.14.10.1.4
-- bmJarHealthNormalClass .2.12.14.10.1.5
-- bmJarHealthLowActions .2.12.14.10.1.6
-- bmJarHealthLowTrapNum .2.12.14.10.1.7
-- bmJarHealthLowClass .2.12.14.10.1.8
-- bmJarHealthVLowActions .2.12.14.10.1.9
-- bmJarHealthVLowTrapNum .2.12.14.10.1.10
-- bmJarHealthVLowClass .2.12.14.10.1.11
-- bmJarHealthSysrepEnable .2.12.14.10.1.12
-- evLocation .2.12.15
-- evLocationEnable .2.12.15.1
-- evLocationTimeout .2.12.15.2
-- evLocationActions .2.12.15.3
-- evLocationMsgSuccess .2.12.15.4
-- evLocationMsgFail .2.12.15.5
-- evLocationIncludeLocation .2.12.15.6
-- evLocationTrapnum .2.12.15.7
-- evLocationClass .2.12.15.8
-- evReset .2.12.16
-- evResetEnable .2.12.16.1
-- evResetDelay .2.12.16.2
-- evResetActions .2.12.16.3
-- evResetMessage .2.12.16.4
-- evResetTrapnum .2.12.16.5
-- evResetClass .2.12.16.6
-- evSleep .2.12.17
-- evSleepEnable .2.12.17.1
-- evSleepActions .2.12.17.3
-- evSleepMessage .2.12.17.4
-- evSleepTrapnum .2.12.17.5
-- evSleepClass .2.12.17.6
-- evGlobal .2.12.18
-- evGlobalActions .2.12.18.1
-- evGlobalTrapnum .2.12.18.2
-- accessControl .2.12.21
-- acActions .2.12.21.2
-- acTrapnum .2.12.21.3
-- acClass .2.12.21.4
-- accessControlDeviceTable .2.12.21.10
-- accessControlDeviceEntry .2.12.21.10.1
-- acdIndex .2.12.21.10.1.1
-- acdEnable .2.12.21.10.1.2
-- acdName .2.12.21.10.1.3
-- acdReader .2.12.21.10.1.4
-- acdWiegandES .2.12.21.10.1.6
-- acdRelayType .2.12.21.10.1.7
-- acdRelayES .2.12.21.10.1.8
-- acdRelayPoint .2.12.21.10.1.9
-- acdOpenTime .2.12.21.10.1.10
-- acdUserGroup .2.12.21.10.1.11
-- accessControlUserTable .2.12.21.11
-- accessControlUserEntry .2.12.21.11.1
-- acuIndexUserGroup .2.12.21.11.1.1
-- acuIndexUser .2.12.21.11.1.2
-- acuEnable .2.12.21.11.1.3
-- acuName .2.12.21.11.1.4
-- acuSn .2.12.21.11.1.5
-- acuSunBegin .2.12.21.11.1.6
-- acuSunEnd .2.12.21.11.1.7
-- acuMonBegin .2.12.21.11.1.8
-- acuMonEnd .2.12.21.11.1.9
-- acuTueBegin .2.12.21.11.1.10
-- acuTueEnd .2.12.21.11.1.11
-- acuWedBegin .2.12.21.11.1.12
-- acuWedEnd .2.12.21.11.1.13
-- acuThuBegin .2.12.21.11.1.14
-- acuThuEnd .2.12.21.11.1.15
-- acuFriBegin .2.12.21.11.1.16
-- acuFriEnd .2.12.21.11.1.17
-- acuSatBegin .2.12.21.11.1.18
-- acuSatEnd .2.12.21.11.1.19
-- action .2.14
-- actionSched .2.14.3
-- actionSchedEnable .2.14.3.1
-- actionSchedBegin .2.14.3.2
-- actionSchedEnd .2.14.3.3
-- actionSchedWeekdaysOnly .2.14.3.4
-- actionAsentria .2.14.4
-- actionAsentriaRequireAck .2.14.4.1
-- actionAsentriaVersion .2.14.4.2
-- actionAsentriaTCPPort .2.14.4.3
-- actionHostTable .2.14.6
-- actionHostEntry .2.14.6.1
-- actionHostIndex .2.14.6.1.1
-- actionHost .2.14.6.1.2
-- actionEmailTable .2.14.7
-- actionEmailEntry .2.14.7.1
-- actionEmailIndex .2.14.7.1.1
-- actionEmail .2.14.7.1.2
-- actionParseError .2.14.8
-- sys .2.16
-- sysTime .2.16.1
-- sysTimeAutoDST .2.16.1.1
-- sysTimeGMTOffset .2.16.1.2
-- sysTimeGMTDirection .2.16.1.3
-- sysTimeNet .2.16.1.4
-- sysTimeNetEnable .2.16.1.4.1
-- sysTimeNetHostTable .2.16.1.4.2
-- sysTimeNetHostEntry .2.16.1.4.2.1
-- sysTimeNetHostIndex .2.16.1.4.2.1.1
-- sysTimeNetHost .2.16.1.4.2.1.2
-- sysPT .2.16.2
-- sysPTTimeout .2.16.2.1
-- sysPTEndPause .2.16.2.2
-- sysPTJoinable .2.16.2.3
-- sysMTU .2.16.3
-- sysAnswerString .2.16.4
-- sysEventFileID .2.16.6
-- sysEscapeCharacter .2.16.7
-- sysTimeStamp .2.16.8
-- sysTimeStampTimeFormat .2.16.8.1
-- sysTimeStampDateFormat .2.16.8.2
-- sysTimeStampSpaceAfter .2.16.8.3
-- sysLog .2.16.9
-- sysLogMode .2.16.9.1
-- sysLoghost .2.16.9.2
-- sysLogFilter .2.16.9.3
-- sysLogFileSize .2.16.9.4
-- sysLogFileCount .2.16.9.5
-- sysLogListenPort .2.16.9.6
-- sysCRDB .2.16.10
-- sysCRDBCapacity .2.16.10.1
-- sysCRDBPercentFull .2.16.10.2
-- sysCRDBFileIDTable .2.16.10.3
-- sysCRDBFileIDEntry .2.16.10.3.1
-- sysCRDBFileIDIndex .2.16.10.3.1.1
-- sysCRDBFileID .2.16.10.3.1.2
-- sysCRDBFileEnforceMinTable .2.16.10.4
-- sysCRDBFileEnforceMinEntry .2.16.10.4.1
-- sysCRDBFileEnforceMinIndex .2.16.10.4.1.1
-- sysCRDBFileEnforceMin .2.16.10.4.1.2
-- sysCharMask .2.16.11
-- sysPrompt .2.16.12
-- sysBootStatus .2.16.13
-- sysLoc .2.16.14
-- sysLocLatitude .2.16.14.1
-- sysLocLongitude .2.16.14.2
-- sysLocXOffset .2.16.14.3
-- sysLocYOffset .2.16.14.4
-- sysLocAngle .2.16.14.5
-- sysLocAltitude .2.16.14.6
-- sysSleep .2.16.16
-- sysSleepEnable .2.16.16.1
-- sysSleepSleep .2.16.16.2
-- sysSleepForceSleep .2.16.16.2.1
-- sysSleepSleepTimer .2.16.16.2.2
-- sysSleepWake .2.16.16.3
-- sysSleepWakeTimerNormal .2.16.16.3.1
-- sysSleepWakeTimerMotion .2.16.16.3.2
-- sysSleepWakeMotionEnable .2.16.16.3.3
-- sysSleepWakeScheduledEnable .2.16.16.3.4
-- sysSleepWakeScheduledTimeOfDay .2.16.16.3.5
-- sysSleepPowerDetectCC .2.16.16.4
-- sysSleepPowerDetectCCEnable .2.16.16.4.1
-- sysSleepPowerDetectCCPowerOnState .2.16.16.4.2
-- sysSleepPowerDetectCCThreshold .2.16.16.4.3
-- sysFileTransfer .2.16.17
-- sysFileTransferStatus .2.16.17.1
-- sysFileTransferURL .2.16.17.2
-- sysFileTransferUsername .2.16.17.3
-- sysFileTransferPassword .2.16.17.4
-- sysUpdate .2.16.18
-- sysUpdateStatus .2.16.18.1
-- auditLog .2.17
-- auditLogEnable .2.17.1
-- auditLogStoreResets .2.17.2
-- auditLogStoreCommands .2.17.3
-- auditLogStoreOutputs .2.17.4
-- auditLogStoreAlarmActions .2.17.5
-- auditLogStorePwdFailures .2.17.6
-- auditLogStoreLogins .2.17.7
-- auditLogStoreSHSK .2.17.8
-- auditLogStorePassthrough .2.17.9
-- auditLogStoreInactivity .2.17.10
-- auditLogStorePolling .2.17.11
-- auditLogMaxSize .2.17.12
-- auditLogSoreSleepActivity .2.17.13
-- scripting .2.18
-- scrGlobalEnable .2.18.1
-- scrDTRCtrlPortEnableTable .2.18.2
-- scrDTRCtrlPortEnableEnabletry .2.18.2.1
-- scrDTRCtrlPortEnableIndex .2.18.2.1.1
-- scrDTRCtrlPortEnable .2.18.2.1.2
-- scrTable .2.18.3
-- scrEntry .2.18.3.1
-- scrIndex .2.18.3.1.1
-- scrEnable .2.18.3.1.2
-- scrName .2.18.3.1.3
-- scrFilename .2.18.3.1.4
-- scrRunAlways .2.18.3.1.5
-- scrRunAtStartup .2.18.3.1.6
-- scrRunScheduled .2.18.3.1.7
-- scrScheduleTime .2.18.3.1.8
-- scrArguments .2.18.3.1.9
-- scrRepeatInterval .2.18.3.1.10
-- scrVolatileStringTable .2.18.4
-- scrVolatileStringEntry .2.18.4.1
-- scrVolatileStringIndex .2.18.4.1.1
-- scrVolatileString .2.18.4.1.2
-- scrVolatileIntTable .2.18.5
-- scrVolatileIntEntry .2.18.5.1
-- scrVolatileIntIndex .2.18.5.1.1
-- scrVolatileInt .2.18.5.1.2
-- scrNonVolatileStringTable .2.18.6
-- scrNonVolatileStringEntry .2.18.6.1
-- scrNonVolatileStringIndex .2.18.6.1.1
-- scrNonVolatileString .2.18.6.1.2
-- scrNonVolatileIntTable .2.18.7
-- scrNonVolatileIntEntry .2.18.7.1
-- scrNonVolatileIntIndex .2.18.7.1.1
-- scrNonVolatileInt .2.18.7.1.2
-- generator .2.19
-- genSet .2.19.1
-- genSetEnable .2.19.1.1
-- genSetRelay .2.19.1.2
-- genSetRelayEs .2.19.1.2.1
-- genSetRelayPoint .2.19.1.2.2
-- genSetRelayRunningstate .2.19.1.2.3
-- genSetRelayTable .2.19.1.2.5
-- genSetRelayTableEntry .2.19.1.2.5.1
-- genSetRelayTableIndex .2.19.1.2.5.1.1
-- genSetRelayTableEnable .2.19.1.2.5.1.2
-- genSetRelayTableEs .2.19.1.2.5.1.3
-- genSetRelayTablePoint .2.19.1.2.5.1.4
-- genSetRelayTableRunningstate .2.19.1.2.5.1.5
-- genSetCc .2.19.1.3
-- genSetCcEnable .2.19.1.3.1
-- genSetCcEs .2.19.1.3.2
-- genSetCcPoint .2.19.1.3.3
-- genSetCcRunningstate .2.19.1.3.4
-- genSetCCDelay .2.19.1.3.5
-- genRun .2.19.2
-- genRunMode .2.19.2.1
-- genRunSched .2.19.2.2
-- genRunDuration .2.19.2.3
-- genRunForce .2.19.2.4
-- genRunReqasm .2.19.2.5
-- genRunStatus .2.19.2.6
-- genRunNonstartEvent .2.19.2.7
-- genRunNonstartEventEnable .2.19.2.7.1
-- genRunNonstartEventActions .2.19.2.7.2
-- genRunNonstartEventTrap .2.19.2.7.3
-- genRunNonstartEventClass .2.19.2.7.4
-- calendar .2.20
-- schedTable .2.20.1
-- schedEntry .2.20.1.1
-- schedIndex .2.20.1.1.1
-- schedEnable .2.20.1.1.2
-- schedStart .2.20.1.1.3
-- schedRepeatMode .2.20.1.1.4
-- schedRepeatFreq .2.20.1.1.5
-- schedRepeatEndMode .2.20.1.1.6
-- schedRepeatEndAfter .2.20.1.1.7
-- schedRepeatEndOn .2.20.1.1.8
-- schedRepeatWeeklySun .2.20.1.1.9
-- schedRepeatWeeklyMon .2.20.1.1.10
-- schedRepeatWeeklyTue .2.20.1.1.11
-- schedRepeatWeeklyWed .2.20.1.1.12
-- schedRepeatWeeklyThu .2.20.1.1.13
-- schedRepeatWeeklyFri .2.20.1.1.14
-- schedRepeatWeeklySat .2.20.1.1.15
-- schedRepeatMonthlyMode .2.20.1.1.16
-- schedRepeatMonthlyDates .2.20.1.1.17
-- schedRepeatMonthlyOnThe .2.20.1.1.18
-- schedRepeatMonthlyOnDay .2.20.1.1.19
-- schedRepeatYearlyJan .2.20.1.1.20
-- schedRepeatYearlyFeb .2.20.1.1.21
-- schedRepeatYearlyMar .2.20.1.1.22
-- schedRepeatYearlyApr .2.20.1.1.23
-- schedRepeatYearlyMay .2.20.1.1.24
-- schedRepeatYearlyJun .2.20.1.1.25
-- schedRepeatYearlyJul .2.20.1.1.26
-- schedRepeatYearlyAug .2.20.1.1.27
-- schedRepeatYearlySep .2.20.1.1.28
-- schedRepeatYearlyOct .2.20.1.1.29
-- schedRepeatYearlyNov .2.20.1.1.30
-- schedRepeatYearlyDec .2.20.1.1.31
-- schedRepeatYearlyOnThe .2.20.1.1.32
-- schedRepeatYearlyOnDay .2.20.1.1.33
-- schedNextTrigger .2.20.1.1.34
-- productIds .3
-- siteName 3.1
-- thisProduct .3.2
-- stockTrapString .3.3
-- trapEventTypeNumber .3.4
-- trapEventTypeName .3.5
-- trapIncludedValue .3.6
-- trapIncludedString .3.7
-- trapTypeString .3.8
-- trapEventClassNumber .3.9
-- trapEventClassName .3.10
-- keyInterface .4.0
--***************************************************************************************
--TOP-LEVEL OBJECT IDENTIFIERS
--***************************************************************************************
s350Notifications OBJECT IDENTIFIER ::= { s350 0 }
--1.3.6.1.4.1.3052.18.0
status OBJECT IDENTIFIER ::= { s350 1 }
--1.3.6.1.4.1.3052.18.1
eventSensorStatus OBJECT IDENTIFIER ::= { status 1 }
--1.3.6.1.4.1.3052.18.1.1
dataEventStatus OBJECT IDENTIFIER ::= { status 2 }
--1.3.6.1.4.1.3052.18.1.2
powerDistributionStatus OBJECT IDENTIFIER ::= { status 5 }
--1.3.6.1.4.1.3052.18.1.5
pdNextGen OBJECT IDENTIFIER ::= { powerDistributionStatus 4 }
--1.3.6.1.4.1.3052.18.1.5.4
pdSystem OBJECT IDENTIFIER ::= { powerDistributionStatus 5 }
--1.3.6.1.4.1.3052.18.1.5.5
fuelSensorStatus OBJECT IDENTIFIER ::= { status 6 }
--1.3.6.1.4.1.3052.18.1.6
wirelessModemStatus OBJECT IDENTIFIER ::= { status 7 }
--1.3.6.1.4.1.3052.18.1.7
acPowerMonitorStatus OBJECT IDENTIFIER ::= { status 8 }
--1.3.6.1.4.1.3052.18.1.8
batteryMonitorStatus OBJECT IDENTIFIER ::= { status 10 }
--1.3.6.1.4.1.3052.18.1.10
config OBJECT IDENTIFIER ::= { s350 2 }
--1.3.6.1.4.1.3052.18.2
eventSensorBasics OBJECT IDENTIFIER ::= { config 1 }
--1.3.6.1.4.1.3052.18.2.1
eventSensorPointConfig OBJECT IDENTIFIER ::= { config 2 }
--1.3.6.1.4.1.3052.18.2.2
serialPorts OBJECT IDENTIFIER ::= { config 3 }
--1.3.6.1.4.1.3052.18.2.3
network OBJECT IDENTIFIER ::= { config 4 }
--1.3.6.1.4.1.3052.18.2.4
interface OBJECT IDENTIFIER ::= { network 1 }
--1.3.6.1.4.1.3052.18.2.4
ethernet OBJECT IDENTIFIER ::= { interface 1 }
--1.3.6.1.4.1.3052.18.2.4.1
ethernet1 OBJECT IDENTIFIER ::= { ethernet 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1
eth1VLAN OBJECT IDENTIFIER ::= { ethernet1 5 }
--1.3.6.1.4.1.3052.18.2.4.1.1.5
eth1VLAN1 OBJECT IDENTIFIER ::= { eth1VLAN 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.5.1
eth1VLAN2 OBJECT IDENTIFIER ::= { eth1VLAN 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.5.2
eth1VLAN3 OBJECT IDENTIFIER ::= { eth1VLAN 3 }
--1.3.6.1.4.1.3052.18.2.4.1.1.5.3
eth1VLAN4 OBJECT IDENTIFIER ::= { eth1VLAN 4 }
--1.3.6.1.4.1.3052.18.2.4.1.1.5.4
eth1VLAN5 OBJECT IDENTIFIER ::= { eth1VLAN 5 }
--1.3.6.1.4.1.3052.18.2.4.1.1.5.5
eth1VLAN6 OBJECT IDENTIFIER ::= { eth1VLAN 6 }
--1.3.6.1.4.1.3052.18.2.4.1.1.5.6
eth1IPv6 OBJECT IDENTIFIER ::= { ethernet1 7 }
--1.3.6.1.4.1.3052.18.2.4.1.1.7
eth1IPv6Static OBJECT IDENTIFIER ::= { eth1IPv6 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.7.2
eth1IPv6Auto OBJECT IDENTIFIER ::= { eth1IPv6 3 }
--1.3.6.1.4.1.3052.18.2.4.1.1.7.3
ethernet2 OBJECT IDENTIFIER ::= { ethernet 2 }
--1.3.6.1.4.1.3052.18.2.4.1.2
eth2VLAN OBJECT IDENTIFIER ::= { ethernet2 5 }
--1.3.6.1.4.1.3052.18.2.4.1.2.5
eth2VLAN1 OBJECT IDENTIFIER ::= { eth2VLAN 1 }
--1.3.6.1.4.1.3052.18.2.4.1.2.5.1
eth2VLAN2 OBJECT IDENTIFIER ::= { eth2VLAN 2 }
--1.3.6.1.4.1.3052.18.2.4.1.2.5.2
eth2VLAN3 OBJECT IDENTIFIER ::= { eth2VLAN 3 }
--1.3.6.1.4.1.3052.18.2.4.1.2.5.3
eth2VLAN4 OBJECT IDENTIFIER ::= { eth2VLAN 4 }
--1.3.6.1.4.1.3052.18.2.4.1.2.5.4
eth2VLAN5 OBJECT IDENTIFIER ::= { eth2VLAN 5 }
--1.3.6.1.4.1.3052.18.2.4.1.2.5.5
eth2VLAN6 OBJECT IDENTIFIER ::= { eth2VLAN 6 }
--1.3.6.1.4.1.3052.18.2.4.1.2.5.6
eth2IPv6 OBJECT IDENTIFIER ::= { ethernet2 7 }
--1.3.6.1.4.1.3052.18.2.4.1.2.7
eth2IPv6Static OBJECT IDENTIFIER ::= { eth2IPv6 2 }
--1.3.6.1.4.1.3052.18.2.4.1.2.7.2
eth2IPv6Auto OBJECT IDENTIFIER ::= { eth2IPv6 3 }
--1.3.6.1.4.1.3052.18.2.4.1.2.7.3
snmp OBJECT IDENTIFIER ::= { network 8 }
--1.3.6.1.4.1.3052.18.2.4.8
snmpNotificationTx OBJECT IDENTIFIER ::= { snmp 7 }
--1.3.6.1.4.1.3052.18.2.4.8.7
snmpProxy OBJECT IDENTIFIER ::= { snmp 8 }
--1.3.6.1.4.1.3052.18.2.4.8.8
snmpPoll OBJECT IDENTIFIER ::= { snmp 9 }
--1.3.6.1.4.1.3052.18.2.4.8.9
ftpPush OBJECT IDENTIFIER ::= { network 9 }
--1.3.6.1.4.1.3052.18.2.4.9
routing OBJECT IDENTIFIER ::= { network 11 }
--1.3.6.1.4.1.3052.18.2.4.11
netSecurity OBJECT IDENTIFIER ::= { network 12 }
--1.3.6.1.4.1.3052.18.2.4.12
ipRestriction OBJECT IDENTIFIER ::= { netSecurity 1 }
--1.3.6.1.4.1.3052.18.2.4.12.1
trap OBJECT IDENTIFIER ::= { network 14 }
--1.3.6.1.4.1.3052.18.2.4.14
trapInclude OBJECT IDENTIFIER ::= { trap 1}
--1.3.6.1.4.1.3052.18.2.4.14.1
wireless OBJECT IDENTIFIER ::= { network 16 }
--1.3.6.1.4.1.3052.18.2.4.16
wirelessConnectivity OBJECT IDENTIFIER ::= { wireless 20 }
--1.3.6.1.4.1.3052.18.2.4.16.20
email OBJECT IDENTIFIER ::= { network 17 }
--1.3.6.1.4.1.3052.18.2.4.17
netAdvanced OBJECT IDENTIFIER ::= { network 18 }
--1.3.6.1.4.1.3052.18.2.4.18
web OBJECT IDENTIFIER ::= { network 19 }
--1.3.6.1.4.1.3052.18.2.4.19
ipv6 OBJECT IDENTIFIER ::= { network 21 }
--1.3.6.1.4.1.3052.18.2.4.21
cpe OBJECT IDENTIFIER ::= { network 22 }
--1.3.6.1.4.1.3052.18.2.4.22
time OBJECT IDENTIFIER ::= { config 8 }
--1.3.6.1.4.1.3052.18.2.8
console OBJECT IDENTIFIER ::= { config 10 }
--1.3.6.1.4.1.3052.18.2.10
unitSecurity OBJECT IDENTIFIER ::= { config 11 }
--1.3.6.1.4.1.3052.18.2.11
secCore OBJECT IDENTIFIER ::= { unitSecurity 1 }
--1.3.6.1.4.1.3052.18.2.11.1
secFactory OBJECT IDENTIFIER ::= { unitSecurity 3 }
--1.3.6.1.4.1.3052.18.2.11.3
event OBJECT IDENTIFIER ::= { config 12 }
--1.3.6.1.4.1.3052.18.2.12
evCore OBJECT IDENTIFIER ::= { event 1 }
--1.3.6.1.4.1.3052.18.2.12.1
evLog OBJECT IDENTIFIER ::= { evCore 3 }
--1.3.6.1.4.1.3052.18.2.12.1.3
evMgmt OBJECT IDENTIFIER ::= { evCore 4 }
--1.3.6.1.4.1.3052.18.2.12.1.4
evSched1 OBJECT IDENTIFIER ::= { event 5 }
--1.3.6.1.4.1.3052.18.2.12.5
evSched2 OBJECT IDENTIFIER ::= { event 6 }
--1.3.6.1.4.1.3052.18.2.12.6
evNoSensor OBJECT IDENTIFIER ::= { event 9 }
--1.3.6.1.4.1.3052.18.2.12.9
fuelSensor OBJECT IDENTIFIER ::= { event 11 }
--1.3.6.1.4.1.3052.18.2.12.11
acPowerMonitor OBJECT IDENTIFIER ::= { event 12 }
--1.3.6.1.4.1.3052.18.2.12.12
batteryMonitor OBJECT IDENTIFIER ::= { event 14 }
--1.3.6.1.4.1.3052.18.2.12.14
evLocation OBJECT IDENTIFIER ::= { event 15 }
--1.3.6.1.4.1.3052.18.2.12.15
evReset OBJECT IDENTIFIER ::= { event 16 }
--1.3.6.1.4.1.3052.18.2.12.16
evSleep OBJECT IDENTIFIER ::= { event 17 }
--1.3.6.1.4.1.3052.18.2.12.17
evGlobal OBJECT IDENTIFIER ::= { event 18 }
--1.3.6.1.4.1.3052.18.2.12.18
accessControl OBJECT IDENTIFIER ::= { event 21 }
--1.3.6.1.4.1.3052.18.2.12.21
action OBJECT IDENTIFIER ::= { config 14 }
--1.3.6.1.4.1.3052.18.2.14
actionSched OBJECT IDENTIFIER ::= { action 3 }
--1.3.6.1.4.1.3052.18.2.14.3
actionAsentria OBJECT IDENTIFIER ::= { action 4 }
--1.3.6.1.4.1.3052.18.2.14.4
sys OBJECT IDENTIFIER ::= { config 16 }
--1.3.6.1.4.1.3052.18.2.16
sysTime OBJECT IDENTIFIER ::= { sys 1 }
--1.3.6.1.4.1.3052.18.2.16.1
sysTimeNet OBJECT IDENTIFIER ::= { sysTime 4 }
--1.3.6.1.4.1.3052.18.2.16.1.4
sysPT OBJECT IDENTIFIER ::= { sys 2 }
--1.3.6.1.4.1.3052.18.2.16.2
sysTimeStamp OBJECT IDENTIFIER ::= { sys 8 }
--1.3.6.1.4.1.3052.18.2.16.8
sysLog OBJECT IDENTIFIER ::= { sys 9 }
--1.3.6.1.4.1.3052.18.2.16.9
sysCRDB OBJECT IDENTIFIER ::= { sys 10 }
--1.3.6.1.4.1.3052.18.2.16.10
sysLoc OBJECT IDENTIFIER ::= { sys 14 }
--1.3.6.1.4.1.3052.18.2.16.14
sysSleep OBJECT IDENTIFIER ::= { sys 16 }
--1.3.6.1.4.1.3052.18.2.16.16
sysSleepSleep OBJECT IDENTIFIER ::= { sysSleep 2 }
--1.3.6.1.4.1.3052.18.2.16.16.2
sysSleepWake OBJECT IDENTIFIER ::= { sysSleep 3 }
--1.3.6.1.4.1.3052.18.2.16.16.3
sysSleepPowerDetectCC OBJECT IDENTIFIER ::= { sysSleep 4 }
--1.3.6.1.4.1.3052.18.2.16.16.4
sysFileTransfer OBJECT IDENTIFIER ::= { sys 17 }
--1.3.6.1.4.1.3052.18.2.16.17
sysUpdate OBJECT IDENTIFIER ::= { sys 18 }
--1.3.6.1.4.1.3052.18.2.16.18
auditLog OBJECT IDENTIFIER ::= { config 17 }
--1.3.6.1.4.1.3052.18.2.17
scripting OBJECT IDENTIFIER ::= { config 18 }
--1.3.6.1.4.1.3052.18.2.18
generator OBJECT IDENTIFIER ::= { config 19 }
--1.3.6.1.4.1.3052.18.2.19
genSet OBJECT IDENTIFIER ::= { generator 1 }
--1.3.6.1.4.1.3052.18.2.19.1
genSetRelay OBJECT IDENTIFIER ::= { genSet 2 }
--1.3.6.1.4.1.3052.18.2.19.1.2
genSetCC OBJECT IDENTIFIER ::= { genSet 3 }
--1.3.6.1.4.1.3052.18.2.19.1.3
genRun OBJECT IDENTIFIER ::= { generator 2 }
--1.3.6.1.4.1.3052.18.2.19.2
genRunNonstartEvent OBJECT IDENTIFIER ::= { genRun 7 }
--1.3.6.1.4.1.3052.18.2.19.2.7
calendar OBJECT IDENTIFIER ::= { config 20 }
--1.3.6.1.4.1.3052.18.2.20
productIds OBJECT IDENTIFIER ::= { s350 3 }
--1.3.6.1.4.1.3052.18.3
--***************************************************************************************
--OBJECT DEFINITIONS
--***************************************************************************************
--***************************************************************************************
--EventSensor Status Section 1.1
--***************************************************************************************
esPointTable OBJECT-TYPE
SYNTAX SEQUENCE OF ESPoint
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
This table organizes 4 basic attributes of points. A point
is a particular sensor on an EventSensor (e.g., temperature,
humidity, contact closure 2, output 5, etc.). The 4 point
attributes are its name, whether it's in its event state,
the point's value as a number and its value as a string.
Points are referenced by a point index. The point index
is a string of 3 numbers separated by periods.
It contains all the information necessary for getting a piece
of data off an event sensor; namely, which EventSensor,
point class, and which-sensor-of-that-class (a.k.a. point).
"
::= { eventSensorStatus 1 }
--1.3.6.1.4.1.3052.18.1.1.1
esPointEntry OBJECT-TYPE
SYNTAX ESPoint
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for EventSensor point table"
INDEX { esIndexES, esIndexPC, esIndexPoint }
::= { esPointTable 1 }
--1.3.6.1.4.1.3052.18.1.1.1.1
esIndexES OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that refers to an
EventSensor.
The point index is a string of 3 numbers separated
by periods. It contains all the information
necessary for getting a piece of data off an event
sensor; namely, which EventSensor, point class,
and which-sensor-of-that-class (a.k.a. point).
This object's allowable values are 1 through 16,
and 200. 200 always refers to the EventSensor
inside the unit. 1 through 16 refer to additional
attached EventSensors.
The number corresponding to an EventSensor is
determined by the user at the initial configuration
time. If there is an internal sensor in the unit,
it will always be the first item in the Sensor
Events setup menu.
For example, if a new EventSensor is configured as
the 2nd entry AFTER the internal EventSensor (if
one exists) in the Sensor Events Setup Menu, then
that EventSensor will be known from then on as
EventSensor 2. All point indeces with esIndexES=2
will now refer to that particular EventSensor.
"
::= { esPointEntry 1 }
--1.3.6.1.4.1.3052.18.1.1.1.1.1
esIndexPC OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that refers to point class.
The point index is a string of 3 numbers separated by periods.
It contains all the information necessary for getting a piece
of data off an event sensor; namely, which EventSensor,
point class, and which-sensor-of-that-class (a.k.a. point).
The values for this object are:
1=temperature sensor
2=contact closure
3=humidity sensor
4=noise sensor
5=analog input
6=output (relay output or power output)
"
::= { esPointEntry 2 }
--1.3.6.1.4.1.3052.18.1.1.1.1.2
esIndexPoint OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that delineates which
sensor on the EventSensor.
So this combined with esIndexPC (Point Class or type)
and esIndexES (which EventSensor) uniquely defines each
point (sensor or output) attached to a unit. For
example, if esIndexES is 3, esIndexPC is 1 and
esIndexPoint is 4 then this is the Fourth Temperature
Sensor on EventSensor number 3."
::= { esPointEntry 3 }
--1.3.6.1.4.1.3052.18.1.1.1.1.3
esPointName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the point on an EventSensor. For example,
'AC temp' (in the case of the temperature sensor on an
EventSensor).
There can be multiple points of the same point class on an
EventSensor (e.g., 8 contact closures) and multiple sensor
classes on an EventSensor (e.g., temperature, contact closure,
humidity).
If the point referenced by a given point index is solitary
(e.g., temperature sensor, because there can be only one on
an EventSensor), then this object reads as '<EventSensor
name>'. Setting this object for solitary point indices sets
the EventSensor name only.
On the other hand, if a given point is among other points of
the same point class on an EventSensor, then this object reads
as '<Sensor name>'. Setting this object for these NON-
solitary point indices sets the sensor name only - not the
EventSensor name."
::= { esPointEntry 4 }
--1.3.6.1.4.1.3052.18.1.1.1.1.4
esPointInEventState OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A number referring to the event state of a point
on an EventSensor. This number can have different
meanings depending on the point class.
If the point class is temperature, humidity, or
analog input, then the values of this object are:
1=very low
2=low
3=normal
4=high
5=very high
For contact closures the values of this object are:
1=point in event state
2=point in normal state
For outputs the values of this object is the numeric
code for the logical state of the output: 1 or 2. The
logical state of the output is either active/inactive for
relay outputs or on/off for power outputs. The logical
state of the output has different nomenclature depending
on the type of the output (relay output or power output):
1=active (for relay output) or on (for power output)
2=inactive (for relay output) or off (for power output)
This is not necessarily representative of physical state
of the output. Physical state is energized/de-energized,
for both relay and power outputs. For relay outputs,
the active logical state corresponds to either the energized
physical state or the de-energized physical state depending
on how the relay output is configured. For power outputs,
the on logical state always corresponds to the energized
physical state.
For any point class and any point, if the event
state is undefined, then the value of this object
is 0.
For any point class except output, this object is read-only.
For outputs, setting this object to 1 puts the output into
its active logical state.
Setting this object to 2 puts the output into its inactive
logical state.
Setting this object to any value greater than 2 puts the
output into its active logical state for that many seconds
(up to 3600), after which time it puts the output into its
inactive logical state.
"
::= { esPointEntry 5 }
--1.3.6.1.4.1.3052.18.1.1.1.1.5
esPointValueInt OBJECT-TYPE
SYNTAX Integer32 (-2147483648..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A read-only number referring to the value of a
point on an EventSensor.
If the point class is temperature, then this object
is the temperature in its configured scale (default
is Fahrenheit).
If the point class is contact closure, then
this object is either 0 (open) or 1 (closed).
If the point class is humidity, then this object
is the percent relative humidity.
If the point class is analog input, then this
object is the signed input value in tenths of the
configured units.
If the point class is an output, then this object is
the numeric code for the physical state of the output.
0=de-energized
1=energized
This object cannot be used to control the output, i.e,
change its logical or physical state (instead use
the esPointInEventState object).
"
::= { esPointEntry 6 }
--1.3.6.1.4.1.3052.18.1.1.1.1.6
esPointValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A string referring to the value of a point on an
EventSensor.
For contact closures this object is either 'Open'
or 'Closed'.
For outputs this object is a concatenation of the
logical state and physical state, separated by '/'.
For a relay output this object can be one of the
following 4 possible values:
Active/Energized
Inactive/Energized
Active/De-energized
Inactve/De-energized
For a power output this object can be one of the
following 2 possible values:
On/Energized
Off/De-energized
For temperature and humidity point classes, this
object is the string representation of the
esPointValueInt object. For temperature, 'C' or
'F' is including in the string to indicate scale.
For analog inputs, this object is the string
representation of the plus/minus input in the
configured units appended with the unit name.
"
::= { esPointEntry 7 }
--1.3.6.1.4.1.3052.18.1.1.1.1.7
esPointTimeLastChange OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time of the last time an event was
triggerred for a point on an EventSensor in
MM/DD/YY HH:MM:SS format.
For contact closures, the possible events are
Active and Inactive. For temperature, humidity,
and analog inputs, the possible events are Normal,
High, Very High, Low, and Very Low.
For outputs, this object is a null string."
::= { esPointEntry 8 }
--1.3.6.1.4.1.3052.18.1.1.1.1.8
esPointTimetickLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time of the last time an event was
triggerred for a point on an EventSensor in
100ths of seconds since reset.
For contact closures, the possible events are
Active and Inactive. For temperature, humidity,
and analog inputs, the possible events are Normal,
High, Very High, Low, and Very Low.
For outputs, this object is a null string."
::= { esPointEntry 9 }
--1.3.6.1.4.1.3052.18.1.1.1.1.9
esPointAliasValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For CC inputs, this is the CC active/inactive alias setting
setting value that currently corresponds to the event state.
So if the CC input is in the event state, then this object
is the active alias setting value. If the CC input is in the
normal state, then this object is the inactive alias setting
value.
For relay/power outputs, this is the output active/inactive
alias setting value that currently corresponds to the output
state. So if the output is in the active state, then this
object is the active alias setting value. If the output is
in hte inactive state, then this object is the inactive alias
setting value.
For non-CC and non-output sensors, this is the same as the
esPointValueStr object."
::= { esPointEntry 10 }
--1.3.6.1.4.1.3052.18.1.1.1.1.10
--***************************************************************************************
--Data Event Status Section 1.2
--***************************************************************************************
deStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF DEStatus
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Data Event Status Table"
::= { dataEventStatus 1 }
--1.3.6.1.4.1.3052.18.1.2.1
deStatusEntry OBJECT-TYPE
SYNTAX DEStatus
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"EventSensor status entry"
INDEX { deStatusIndex }
::= { deStatusTable 1 }
--1.3.6.1.4.1.3052.18.1.2.1.1
deStatusIndex OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for Data Events"
::= { deStatusEntry 1 }
--1.3.6.1.4.1.3052.18.1.2.1.1.1
deStatusName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Data Event name"
::= { deStatusEntry 2 }
--1.3.6.1.4.1.3052.18.1.2.1.1.2
deStatusCounter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times a data record has matched this
event's equation.
Range: 1-999999999"
::= { deStatusEntry 3 }
--1.3.6.1.4.1.3052.18.1.2.1.1.3
deStatusThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times the equation is matched before
an event is triggered.
Range: 1-999999999"
::= { deStatusEntry 4 }
--1.3.6.1.4.1.3052.18.1.2.1.1.4
--***************************************************************************************
--Power Distribution Status Section 1.5
--***************************************************************************************
pdConfig OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power Distribution output configuration"
::= { powerDistributionStatus 1 }
--1.3.6.1.4.1.3052.18.1.5.1
PowerDistribNextGen ::=
SEQUENCE {
pdnIndexPD
Integer32,
pdnIndexOutput
Integer32,
pdnConfig
DisplayString,
pdnMainCurrentInEventState
DisplayString,
pdnMainCurrentValue
Integer32,
pdnMainCurrentValueStr
DisplayString,
pdnMainCurrentDeadband
Integer32,
pdnMainCurrentVHighCurrent
Integer32,
pdnMainCurrentHighCurrent
Integer32,
pdnMainCurrentLowCurrent
Integer32,
pdnMainCurrentVLowCurrent
Integer32,
pdnMainVoltageInEventState
DisplayString,
pdnMainVoltageValue
Integer32,
pdnMainVoltageValueStr
DisplayString,
pdnMainVoltageDeadband
Integer32,
pdnMainVoltageVHighVoltage
Integer32,
pdnMainVoltageHighVoltage
Integer32,
pdnMainVoltageLowVoltage
Integer32,
pdnMainVoltageVLowVoltage
Integer32,
pdnMainPowerValue
Integer32,
pdnMainPowerValueStr
DisplayString,
pdnOutputCurrentInEventState
DisplayString,
pdnOutputCurrentValue
Integer32,
pdnOutputCurrentValueStr
DisplayString,
pdnOutputCurrentDeadband
Integer32,
pdnOutputCurrentVHighCurrent
Integer32,
pdnOutputCurrentHighCurrent
Integer32,
pdnOutputCurrentLowCurrent
Integer32,
pdnOutputCurrentVLowCurrent
Integer32,
pdnOutputFuseInEventState
DisplayString,
pdnOutputFuseValueStr
DisplayString,
pdnMainCombinedStatus
DisplayString,
pdnOutputCombinedStatusBlock1
DisplayString,
pdnOutputCombinedStatusBlock2
DisplayString,
pdnDeviceCurrentValue
Integer32,
pdnDeviceCurrentValueStr
DisplayString
}
pdnTable OBJECT-TYPE
SYNTAX SEQUENCE OF PowerDistribNextGen
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of power distribution objects arranged according
to next-generation methodology (i.e., using multiple PowerBoss
power distributors in addition to the on-board power
distributor)."
::= { pdNextGen 1 }
--1.3.6.1.4.1.3052.18.1.5.4.1
pdnEntry OBJECT-TYPE
SYNTAX PowerDistribNextGen
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of power distribution objects arranged according
to next-generation methodology (i.e., using multiple PowerBoss
power distributors in addition to the on-board power
distributor)."
INDEX { pdnIndexPD, pdnIndexOutput }
::= { pdnTable 1 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1
pdnIndexPD OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of power distribution objects, specifically the
index that refers to which power distributor. A value of 200 means
the internal power distributor. A value from 1 to 16 refers to an
external power distributor (PowerBoss), and is the same value as esIndexES,
which refers to the PowerBoss as an EventSensor in the eventSensorStatus
object table. In other words, pdnIndexPD is the same as esIndexES:
esIndexES is used to refer to the PowerBoss as an eventsensor (i.e., control
outputs), while pdnIndexPD is used to refer to the PowerBoss when used for
power distribution monitoring (i.e., to alarm on output
current/voltage/fuse status)."
::= { pdnEntry 1 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.1
pdnIndexOutput OBJECT-TYPE
SYNTAX Integer32 (1..12)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of power distribution objects, specifically the
index that refers to which output on the power distributor specified
by pdnIndexPD. For objects where the output is irrelevant, this index
should be 1."
::= { pdnEntry 2 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.2
pdnConfig OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of outputs on the power distributor specified by pdnIndexPD.
pdnIndexOutput should be 1 for this object."
::= { pdnEntry 3 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.3
pdnMainCurrentInEventState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The event state of the current (i.e. Amps) event of the power distributor
specified by pdnIndexPD. pdnIndexOutput should be 1 for this object.
Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High',
'Very High'."
::= { pdnEntry 4 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.4
pdnMainCurrentValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current drawn, in mA, for the power distributor specified by pdnIndexPD.
If pdnIndexPD is 1-16 then this is an external power distributor (PowerBoss) and
refers to the current drawn by that PowerBoss and all equipment powered by that
PowerBoss. pdnIndexOutput should be 1 for this object."
::= { pdnEntry 5 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.5
pdnMainCurrentValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Essentially pdnMainCurrentValue formatted as a string in units of Amps, with
3 decimal places. pdnIndexOutput should be 1 for this object."
::= { pdnEntry 6 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.6
pdnMainCurrentDeadband OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The deadband, in mA, for the main current sensor for the power distributor
specified by pdIndexPD. pdnIndexOutput should be 1 for this object."
::= { pdnEntry 7 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.7
pdnMainCurrentVHighCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current, in mA, for the main current sensor's Very High event threshold,
for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
for this object."
::= { pdnEntry 8 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.8
pdnMainCurrentHighCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current, in mA, for the main current sensor's High event threshold,
for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
for this object."
::= { pdnEntry 9 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.9
pdnMainCurrentLowCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current, in mA, for the main current sensor's Low event threshold,
for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
for this object."
::= { pdnEntry 10 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.10
pdnMainCurrentVLowCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current, in mA, for the main current sensor's Very Low event threshold,
for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
for this object."
::= { pdnEntry 11 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.11
pdnMainVoltageInEventState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The event state of the voltage event of the power distributor
specified by pdnIndexPD. pdnIndexOutput should be 1 for this object.
Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High',
'Very High'."
::= { pdnEntry 12 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.12
pdnMainVoltageValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage, in mV, at the power distributor specified by pdnIndexPD.
If pdnIndexPD is 1-16 then this is an external power distributor (PowerBoss) and
refers to the voltage at that PowerBoss and all equipment powered by that
PowerBoss. pdnIndexOutput should be 1 for this object."
::= { pdnEntry 13 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.13
pdnMainVoltageValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Essentially pdnMainVoltageValue formatted as a string in units of Volts, with
3 decimal places. pdnIndexOutput should be 1 for this object."
::= { pdnEntry 14 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.14
pdnMainVoltageDeadband OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The deadband, in mV, for the main voltage sensor for the power distributor
specified by pdIndexPD. pdnIndexOutput should be 1 for this object."
::= { pdnEntry 15 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.15
pdnMainVoltageVHighVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage, in mA, for the main voltage sensor's Very High event threshold,
for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
for this object."
::= { pdnEntry 16 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.16
pdnMainVoltageHighVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage, in mV, for the main voltage sensor's High event threshold,
for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
for this object."
::= { pdnEntry 17 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.17
pdnMainVoltageLowVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage, in mV, for the main voltage sensor's Low event threshold,
for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
for this object."
::= { pdnEntry 18 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.18
pdnMainVoltageVLowVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage, in mV, for the main voltage sensor's Very Low event threshold,
for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1
for this object."
::= { pdnEntry 19 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.19
pdnMainPowerValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The power, in Watts, for the power distributor specified by pdIndexPD.
pdnIndexOutput should be 1 for this object."
::= { pdnEntry 20 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.20
pdnMainPowerValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The power, in Watts, for the power distributor specified by pdIndexPD,
formatted as a string with the unit name 'Watts'. pdnIndexOutput should be 1
for this object."
::= { pdnEntry 21 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.21
pdnOutputCurrentInEventState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The event state of the current (i.e. Amps) event of the power distributor
output specified by pdnIndexPD and pdnIndexOutput. E.g., for pdnIndexPD=200
and pdnIndexOutput=2, this refers to power output #2 of the internal power
distributor. Possible values for this object are: 'Very Low', 'Low', 'Normal',
'High', 'Very High'."
::= { pdnEntry 22 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.22
pdnOutputCurrentValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current drawn, in mA, for the power distributor output specified by
pdnIndexPD and pdIndexOutput. E.g., if pdIndexPD is 3 then this is an external
power distributor (PowerBoss) identified as 'power distributor 3' and refers to
the current drawn by a specific power output on that PowerBoss. The specific
power output is specified by pdIndexOutput."
::= { pdnEntry 23 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.23
pdnOutputCurrentValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Essentially pdnOutputCurrentValue formatted as a string in units of Amps, with
3 decimal places."
::= { pdnEntry 24 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.24
pdnOutputCurrentDeadband OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The deadband, in mA, for the main current sensor for the power distributor
specified by pdIndexPD. The power output is specified by pdnIndexOutput."
::= { pdnEntry 25 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.25
pdnOutputCurrentVHighCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current, in mA, for a specific power output's current sensor Very High
event threshold, for the power distributor specified by pdIndexPD. The power
output is specified by pdnIndexOutput."
::= { pdnEntry 26 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.26
pdnOutputCurrentHighCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current, in mA, for a specific power output's current sensor High event
threshold, for the power distributor specified by pdIndexPD. The power output
is specified by pdnIndexOutput for this object."
::= { pdnEntry 27 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.27
pdnOutputCurrentLowCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current, in mA, for a specific power output's current sensor Low event
threshold, for the power distributor specified by pdIndexPD. The power output
is specified by pdnIndexOutput for this object."
::= { pdnEntry 28 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.28
pdnOutputCurrentVLowCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current, in mA, for a specific power output's current sensor Very Low
event threshold, for the power distributor specified by pdIndexPD. The power
output is specified by pdnIndexOutput for this object."
::= { pdnEntry 29 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.29
pdnOutputFuseInEventState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The event state of the fuse event of the power distributor output specified
by pdnIndexPD and pdnIndexOutput. E.g., for pdnIndexPD=14 and pdnIndexOutput=2,
this refers to power output #2 of the external power distributor (PowerBoss),
identified as 'power distributor 14'. Possible values for this object are:
'Very Low', 'Low', 'Normal', 'High', 'Very High'. This object exists only for
power distributors with fuse monitoring support."
::= { pdnEntry 30 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.30
pdnOutputFuseValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of the fuse of the power distributor output specified
by pdnIndexPD and pdnIndexOutput. Possible values for this object are:
'BLOWN' and 'OK'. This object exists only for power distributors with
fuse monitoring support."
::= { pdnEntry 31 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.31
pdnMainCombinedStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
format: voltageColorCode`voltageEventState`voltageValue`mainCurrentColorCode`mainCurrentEventState`mainCurrentValue`deviceCurrentValue`mainPowerValue"
::= { pdnEntry 32 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.32
pdnOutputCombinedStatusBlock1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
format: numInBlock~outputCurrentColorCode1`outputCurrentEventState1`outputCurrentValue1`fuseColorCode1`fuseValue1~..."
::= { pdnEntry 33 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.33
pdnOutputCombinedStatusBlock2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
format: numInBlock~outputCurrentColorCode1`outputCurrentEventState1`outputCurrentValue1`fuseColorCode1`fuseValue1~..."
::= { pdnEntry 34 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.34
pdnDeviceCurrentValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current drawn by device in mA. For the internal power distributor device,
this is the current drawn by the SiteBoss 571. For an external power
distributor device (PowerBoss), this is the current drawn by the
PowerBoss. This object exists only for power distributors with device
current monitoring support."
::= { pdnEntry 35 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.35
pdnDeviceCurrentValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current drawn by device as a string with units (Amps). For the internal
power distributor device, this is the current drawn by the SiteBoss 571.
For an external power distributor device (PowerBoss), this is the
current drawn by the PowerBoss. This object exists only for power
distributors with device current monitoring support."
::= { pdnEntry 36 }
--1.3.6.1.4.1.3052.18.1.5.4.1.1.36
pdSystemCurrent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total current drawn by all power distributors in system; that is, the
sum of all pdnMainCurrentValue objects for all connected power
distributors: internal and external."
::= { pdSystem 1 }
--1.3.6.1.4.1.3052.18.1.5.5.1
pdSystemPower OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total power used by all power distributors in system; that is, the
sum of all pdnMainPowerValue objects for all connected power
distributors: internal and external."
::= { pdSystem 2 }
--1.3.6.1.4.1.3052.18.1.5.5.2
--***************************************************************************************
--Fuel Sensor 1.6
--***************************************************************************************
fsStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF FSStatus
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Fuel sensor status table"
::= { fuelSensorStatus 1 }
--1.3.6.1.4.1.3052.18.1.6.1
fsStatusEntry OBJECT-TYPE
SYNTAX FSStatus
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Fuel sensor status table entry"
INDEX { fsStatusIndex }
::= { fsStatusTable 1 }
--1.3.6.1.4.1.3052.18.1.6.1.1
fsStatusIndex OBJECT-TYPE
SYNTAX Integer32 (1..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for fuel sensors"
::= { fsStatusEntry 1 }
--1.3.6.1.4.1.3052.18.1.6.1.1.1
fsStatusName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fuel sensor name"
::= { fsStatusEntry 2 }
--1.3.6.1.4.1.3052.18.1.6.1.1.2
fsStatusDeviceState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fuel sensor device state"
::= { fsStatusEntry 3 }
--1.3.6.1.4.1.3052.18.1.6.1.1.3
fsStatusVolumeValueString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fuel volume. Range is -2,147,483,648 to 2,147,483,647. This value reads
-999 when the fuel sensor is disconnected"
::= { fsStatusEntry 4 }
--1.3.6.1.4.1.3052.18.1.6.1.1.4
fsStatusVolumePercentLevel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Height of the fluid in the tank expressed as a percentage of the tank
height, in hundredths of a percent."
::= { fsStatusEntry 7 }
--1.3.6.1.4.1.3052.18.1.6.1.1.7
fsStatusVolumeInEventState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current event status of the fuel sensor."
::= { fsStatusEntry 8 }
--1.3.6.1.4.1.3052.18.1.6.1.1.8
fsStatusCombined OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
deviceState`deviceStateColorCode`percentRounded`valueAsFloat`volumeEventState`volumeEventStateColorCode`capacity`units`name"
::= { fsStatusEntry 9 }
--1.3.6.1.4.1.3052.18.1.6.1.1.9
--***************************************************************************************
--Wireless Modem Status Section 1.7
--***************************************************************************************
wmsStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem status"
::= { wirelessModemStatus 1 }
--1.3.6.1.4.1.3052.18.1.7.1
wmsSignal OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem Signal strength"
::= { wirelessModemStatus 2 }
--1.3.6.1.4.1.3052.18.1.7.2
wmsRSSI OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem Signal strength (RSSI)"
::= { wirelessModemStatus 3 }
--1.3.6.1.4.1.3052.18.1.7.3
wmsBER OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem Bit Error Rate"
::= { wirelessModemStatus 4 }
--1.3.6.1.4.1.3052.18.1.7.4
wmsUpdated OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem info last update time"
::= { wirelessModemStatus 5 }
--1.3.6.1.4.1.3052.18.1.7.5
wmsRegistration OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem registration status"
::= { wirelessModemStatus 6 }
--1.3.6.1.4.1.3052.18.1.7.6
wmsLAC OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem Location Area Code"
::= { wirelessModemStatus 7 }
--1.3.6.1.4.1.3052.18.1.7.7
wmsCellID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem Cell ID"
::= { wirelessModemStatus 8 }
--1.3.6.1.4.1.3052.18.1.7.8
wmsIMSI OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem Internation Mobile Subscriber Identity number"
::= { wirelessModemStatus 9 }
--1.3.6.1.4.1.3052.18.1.7.9
wmsPhnum OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem phone number"
::= { wirelessModemStatus 10 }
--1.3.6.1.4.1.3052.18.1.7.10
wmsLocalIP OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Local IP address of modem on wireless network"
::= { wirelessModemStatus 11 }
--1.3.6.1.4.1.3052.18.1.7.11
wmsMgfID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem manufacturer ID"
::= { wirelessModemStatus 12 }
--1.3.6.1.4.1.3052.18.1.7.12
wmsModelID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem model ID"
::= { wirelessModemStatus 13 }
--1.3.6.1.4.1.3052.18.1.7.13
wmsIMEI OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem International Mobile Equipment Identity number"
::= { wirelessModemStatus 14 }
--1.3.6.1.4.1.3052.18.1.7.14
wmsRevID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem revision ID"
::= { wirelessModemStatus 15 }
--1.3.6.1.4.1.3052.18.1.7.15
wmsNetName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem network name"
::= { wirelessModemStatus 16 }
--1.3.6.1.4.1.3052.18.1.7.16
wmsGPRSStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem (E)GPRS status"
::= { wirelessModemStatus 17 }
--1.3.6.1.4.1.3052.18.1.7.17
wmsBand OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem band"
::= { wirelessModemStatus 18 }
--1.3.6.1.4.1.3052.18.1.7.18
wmsChannel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem channel"
::= { wirelessModemStatus 19 }
--1.3.6.1.4.1.3052.18.1.7.19
wmsCountryCode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem country code"
::= { wirelessModemStatus 20 }
--1.3.6.1.4.1.3052.18.1.7.20
wmsNetCode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem network code"
::= { wirelessModemStatus 21 }
--1.3.6.1.4.1.3052.18.1.7.21
wmsPLMNColor OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem PLMN color"
::= { wirelessModemStatus 22 }
--1.3.6.1.4.1.3052.18.1.7.22
wmsBScolor OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem BS color"
::= { wirelessModemStatus 23 }
--1.3.6.1.4.1.3052.18.1.7.23
wmsMpRACH OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem max power RACH"
::= { wirelessModemStatus 24 }
--1.3.6.1.4.1.3052.18.1.7.24
wmsMinRxLevel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem minimum receive level"
::= { wirelessModemStatus 25 }
--1.3.6.1.4.1.3052.18.1.7.25
wmsBaseCoeff OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem base coefficient"
::= { wirelessModemStatus 26 }
--1.3.6.1.4.1.3052.18.1.7.26
wmsSIMStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"WWireless modem SIM status"
::= { wirelessModemStatus 27 }
--1.3.6.1.4.1.3052.18.1.7.27
wmsICCID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem SIM ICCID"
::= { wirelessModemStatus 28 }
--1.3.6.1.4.1.3052.18.1.7.28
wmsModemType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wireless modem type"
::= { wirelessModemStatus 29 }
--1.3.6.1.4.1.3052.18.1.7.29
--***************************************************************************************
--AC Power Monitor Section 1.8
--***************************************************************************************
acpmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF ACPMStatus
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"AC power monitor status table"
::= { acPowerMonitorStatus 1 }
--1.3.6.1.4.1.3052.18.1.8.1
acpmStatusEntry OBJECT-TYPE
SYNTAX ACPMStatus
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"AC power monitor status table entry"
INDEX { acpmsIndex }
::= { acpmStatusTable 1 }
--1.3.6.1.4.1.3052.18.1.8.1.1
acpmsIndex OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for AC power monitors"
::= { acpmStatusEntry 1 }
--1.3.6.1.4.1.3052.18.1.8.1.1.1
acpmsName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name for the AC power monitor device."
::= { acpmStatusEntry 2 }
--1.3.6.1.4.1.3052.18.1.8.1.1.2
acpmsAvgVoltageValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average voltage, in volts. This is calculated using the formula
(register * PT ratio * 0.1). This could be either the average of
the phase voltages, or the sum of the phase voltages, depending
on device configuration."
::= { acpmStatusEntry 3 }
--1.3.6.1.4.1.3052.18.1.8.1.1.3
acpmsAvgVoltageMinStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum average voltage value since last reset, in volts."
::= { acpmStatusEntry 4 }
--1.3.6.1.4.1.3052.18.1.8.1.1.4
acpmsAvgVoltageMaxStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum average voltage value since last reset, in volts."
::= { acpmStatusEntry 5 }
--1.3.6.1.4.1.3052.18.1.8.1.1.5
acpmsAvgVoltageAvgStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average average voltage value since last reset, in volts. This is
the unit's average of its measurements of the average voltage
reported by the AC power monitor device."
::= { acpmStatusEntry 6 }
--1.3.6.1.4.1.3052.18.1.8.1.1.6
acpmsAvgVoltageInEventState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event state of this AC power monitor voltage (Low, Normal, High, etc.)."
::= { acpmStatusEntry 7 }
--1.3.6.1.4.1.3052.18.1.8.1.1.7
acpmsVoltagePhaseAValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phase A voltage, in volts. This is calculated using the formula
(register * PT ratio * 0.1)."
::= { acpmStatusEntry 8 }
--1.3.6.1.4.1.3052.18.1.8.1.1.8
acpmsVoltagePhaseBValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phase B voltage, in volts. This is calculated using the formula
(register * PT ratio * 0.1)."
::= { acpmStatusEntry 9 }
--1.3.6.1.4.1.3052.18.1.8.1.1.9
acpmsVoltagePhaseCValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phase C voltage, in volts. This is calculated using the formula
(register * PT ratio * 0.1)."
::= { acpmStatusEntry 10 }
--1.3.6.1.4.1.3052.18.1.8.1.1.10
acpmsAvgCurrentValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average current, in amps. This is calculated using the formula
(register * CT ratio * 0.001). This could be either the average of
the phase currents, or the sum of the phase currents, depending on
device configuration."
::= { acpmStatusEntry 11 }
--1.3.6.1.4.1.3052.18.1.8.1.1.11
acpmsAvgCurrentMinStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum average current value since last reset, in amps."
::= { acpmStatusEntry 12 }
--1.3.6.1.4.1.3052.18.1.8.1.1.12
acpmsAvgCurrentMaxStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum average current value since last reset, in amps."
::= { acpmStatusEntry 13 }
--1.3.6.1.4.1.3052.18.1.8.1.1.13
acpmsAvgCurrentAvgStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average average current value since last reset, in amps. This is
the unit's average of its measurements of the average current reported
by the AC power monitor device."
::= { acpmStatusEntry 14 }
--1.3.6.1.4.1.3052.18.1.8.1.1.14
acpmsAvgCurrentInEventState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event state of this AC power monitor current (Low, Normal, High, etc.)."
::= { acpmStatusEntry 15 }
--1.3.6.1.4.1.3052.18.1.8.1.1.15
acpmsCurrentPhaseAValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phase A current, in amps. This is calculated using the formula
(register * CT ratio * 0.001)."
::= { acpmStatusEntry 16 }
--1.3.6.1.4.1.3052.18.1.8.1.1.16
acpmsCurrentPhaseBValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phase B current, in amps. This is calculated using the formula
(register * CT ratio * 0.001)."
::= { acpmStatusEntry 17 }
--1.3.6.1.4.1.3052.18.1.8.1.1.17
acpmsCurrentPhaseCValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phase C current, in amps. This is calculated using the formula
(register * CT ratio * 0.001)."
::= { acpmStatusEntry 18 }
--1.3.6.1.4.1.3052.18.1.8.1.1.18
acpmsAvgFreqValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frequency, in hertz. On the YD2010, this is calculated using the
formula (register * 0.00106813). On the WattsOn, this is calculated
using the formula (register * 0.1)."
::= { acpmStatusEntry 19 }
--1.3.6.1.4.1.3052.18.1.8.1.1.19
acpmsAvgFreqMinStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum frequency value since last reset, in hertz."
::= { acpmStatusEntry 20 }
--1.3.6.1.4.1.3052.18.1.8.1.1.20
acpmsAvgFreqMaxStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum frequency value since last reset, in hertz."
::= { acpmStatusEntry 21 }
--1.3.6.1.4.1.3052.18.1.8.1.1.21
acpmsAvgFreqAvgStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average frequency value since last reset, in hertz. This is the
unit's average of its measurements of the average frequency reported
by the AC power monitor device."
::= { acpmStatusEntry 22 }
--1.3.6.1.4.1.3052.18.1.8.1.1.22
acpmsAvgFreqInEventState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event state of this AC power monitor frequency (Low, Normal, High, etc.)."
::= { acpmStatusEntry 23 }
--1.3.6.1.4.1.3052.18.1.8.1.1.23
acpmsTRPValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total real power, in watts. On the YD2010, this is calculated using
the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
the voltage range taken from register 0x30A. On the WattsOn models,
this is calculated using the formula (register * PT * CT)."
::= { acpmStatusEntry 24 }
--1.3.6.1.4.1.3052.18.1.8.1.1.24
acpmsTRPMinStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum total real power value since last reset, in watts."
::= { acpmStatusEntry 25 }
--1.3.6.1.4.1.3052.18.1.8.1.1.25
acpmsTRPMaxStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum total real power value since last reset, in watts."
::= { acpmStatusEntry 26 }
--1.3.6.1.4.1.3052.18.1.8.1.1.26
acpmsTRPAvgStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average total real power value since last reset, in watts. This is
the unit's average of its measurements of the average total real power
reported by the AC power monitor device."
::= { acpmStatusEntry 27 }
--1.3.6.1.4.1.3052.18.1.8.1.1.27
acpmsTRPInEventState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event state of this AC power monitor total real power (Low, Normal,
High, etc.)."
::= { acpmStatusEntry 28 }
--1.3.6.1.4.1.3052.18.1.8.1.1.28
acpmsRPPhaseAValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phase A real power, in watts. On the YD2010, this is calculated using
the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
the voltage range taken from register 0x30A. On the WattsOn, this is
calculated using the formula (register * PT * CT)."
::= { acpmStatusEntry 29 }
--1.3.6.1.4.1.3052.18.1.8.1.1.29
acpmsRPPhaseBValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phase B real power, in watts. On the YD2010, this is calculated using
the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
the voltage range taken from register 0x30A. On the WattsOn, this is
calculated using the formula (register * PT * CT)."
::= { acpmStatusEntry 30 }
--1.3.6.1.4.1.3052.18.1.8.1.1.30
acpmsRPPhaseCValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phase C real power, in watts. On the YD2010, this is calculated using
the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is
the voltage range taken from register 0x30A. On the WattsOn, this is
calculated using the formula (register * PT * CT)."
::= { acpmStatusEntry 31 }
--1.3.6.1.4.1.3052.18.1.8.1.1.31
acpmsCombined OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
name`deviceState`deviceStateColorCode`voltage`current`frequency`power~voltageEventState`voltageColorCode`currentEventState`currentColorCode`frequencyEventState`frequencyColorCode`powerEventState`powerColorCode"
::= { acpmStatusEntry 32 }
--1.3.6.1.4.1.3052.18.1.8.1.1.32
acpmsTPFValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total power factor."
::= { acpmStatusEntry 33 }
--1.3.6.1.4.1.3052.18.1.8.1.1.33
acpmsTPFMinStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total power factor minimum value since last reset."
::= { acpmStatusEntry 34 }
--1.3.6.1.4.1.3052.18.1.8.1.1.34
acpmsTPFMaxStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total power factor maximum value since last reset."
::= { acpmStatusEntry 35 }
--1.3.6.1.4.1.3052.18.1.8.1.1.35
acpmsTPFAvgStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total power factor average value since last reset."
::= { acpmStatusEntry 36 }
--1.3.6.1.4.1.3052.18.1.8.1.1.36
acpmsTPFInEventState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total power factor event state."
::= { acpmStatusEntry 37 }
--1.3.6.1.4.1.3052.18.1.8.1.1.37
acpmsPFPhaseAValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phase A power factor."
::= { acpmStatusEntry 38 }
--1.3.6.1.4.1.3052.18.1.8.1.1.38
acpmsPFPhaseBValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phase B power factor."
::= { acpmStatusEntry 39 }
--1.3.6.1.4.1.3052.18.1.8.1.1.39
acpmsPFPhaseCValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phase C power factor."
::= { acpmStatusEntry 40 }
--1.3.6.1.4.1.3052.18.1.8.1.1.40
acpmsTRcPValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total reactive power, in VAR."
::= { acpmStatusEntry 41 }
--1.3.6.1.4.1.3052.18.1.8.1.1.41
acpmsTRcPMinStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total reactive power minimum value since last reset, in VAR."
::= { acpmStatusEntry 42 }
--1.3.6.1.4.1.3052.18.1.8.1.1.42
acpmsTRcPMaxStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total reactive power maximum value since last reset, in VAR."
::= { acpmStatusEntry 43 }
--1.3.6.1.4.1.3052.18.1.8.1.1.43
acpmsTRcPAvgStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total reactive power average value since last reset, in VAR."
::= { acpmStatusEntry 44 }
--1.3.6.1.4.1.3052.18.1.8.1.1.44
acpmsRcPPhaseAValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phase A reactive power, in VAR."
::= { acpmStatusEntry 45 }
--1.3.6.1.4.1.3052.18.1.8.1.1.45
acpmsRcPPhaseBValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phase B reactive power, in VAR."
::= { acpmStatusEntry 46 }
--1.3.6.1.4.1.3052.18.1.8.1.1.46
acpmsRcPPhaseCValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phase C reactive power, in VAR."
::= { acpmStatusEntry 47 }
--1.3.6.1.4.1.3052.18.1.8.1.1.47
acpmsTAPValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total apparent power, in VA."
::= { acpmStatusEntry 48 }
--1.3.6.1.4.1.3052.18.1.8.1.1.48
acpmsTAPMinStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total apparent power minimum value since last reset, in VA."
::= { acpmStatusEntry 49 }
--1.3.6.1.4.1.3052.18.1.8.1.1.49
acpmsTAPMaxStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total apparent power maximum value since last reset, in VA."
::= { acpmStatusEntry 50 }
--1.3.6.1.4.1.3052.18.1.8.1.1.50
acpmsTAPAvgStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total apparent power average value since last reset, in VA."
::= { acpmStatusEntry 51 }
--1.3.6.1.4.1.3052.18.1.8.1.1.51
acpmsAPPhaseAValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phase A apparent power, in VA."
::= { acpmStatusEntry 52 }
--1.3.6.1.4.1.3052.18.1.8.1.1.52
acpmsAPPhaseBValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phase B apparent power, in VA."
::= { acpmStatusEntry 53 }
--1.3.6.1.4.1.3052.18.1.8.1.1.53
acpmsAPPhaseCValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phase C apparent power, in VA."
::= { acpmStatusEntry 54 }
--1.3.6.1.4.1.3052.18.1.8.1.1.54
acpmsTotalEnergyWh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total energy, in Wh."
::= { acpmStatusEntry 55 }
--1.3.6.1.4.1.3052.18.1.8.1.1.55
acpmsTotalEnergyVAR OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total reactive energy, in VAR."
::= { acpmStatusEntry 56 }
--1.3.6.1.4.1.3052.18.1.8.1.1.56
acpmsTotalEnergyVA OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total apparent energy, in VA."
::= { acpmStatusEntry 57 }
--1.3.6.1.4.1.3052.18.1.8.1.1.57
--***************************************************************************************
--Battery Monitor Status Section 1.10
--***************************************************************************************
bmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF BMStatus
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Battery monitor status table."
::= { batteryMonitorStatus 1 }
--1.3.6.1.4.1.3052.18.1.10.1
bmStatusEntry OBJECT-TYPE
SYNTAX BMStatus
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Battery monitor status table entry."
INDEX { bmsIndex }
::= { bmStatusTable 1 }
--1.3.6.1.4.1.3052.18.1.10.1.1
bmsIndex OBJECT-TYPE
SYNTAX Integer32 (1..9)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for battery monitors."
::= { bmStatusEntry 1 }
--1.3.6.1.4.1.3052.18.1.10.1.1.1
bmsEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ON/OFF enable for this battery monitor."
::= { bmStatusEntry 2 }
--1.3.6.1.4.1.3052.18.1.10.1.1.2
bmsName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name for this battery monitor."
::= { bmStatusEntry 3 }
--1.3.6.1.4.1.3052.18.1.10.1.1.3
bmsState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The connected state of the battery monitor. If you unplug the carrier
then all three of its battery monitor states will reflect the same
state change."
::= { bmStatusEntry 4 }
--1.3.6.1.4.1.3052.18.1.10.1.1.4
bmsStringState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the string monitored by its battery monitor."
::= { bmStatusEntry 5 }
--1.3.6.1.4.1.3052.18.1.10.1.1.5
bmsTempValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average jar temperature value in C or F, depending on scale setting.
Displayed as a floating point value. -999.0 means this is unknown."
::= { bmStatusEntry 6 }
--1.3.6.1.4.1.3052.18.1.10.1.1.6
bmsTempValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average jar temperature with appropriate scale appended. Displayed
as a floating point value. -999.0 means this is unknown."
::= { bmStatusEntry 7 }
--1.3.6.1.4.1.3052.18.1.10.1.1.7
bmsTempEvent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event state of this battery monitor average jar temperature (Low,
Normal, High)."
::= { bmStatusEntry 8 }
--1.3.6.1.4.1.3052.18.1.10.1.1.8
bmsDiffTempValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Differential temperature in C or F, depending on scale setting.
-999 means this is unknown."
::= { bmStatusEntry 9 }
--1.3.6.1.4.1.3052.18.1.10.1.1.9
bmsDiffTempValueStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Differential temperature with appropriate scale (C or F) appended.
-999 means this is unknown."
::= { bmStatusEntry 10 }
--1.3.6.1.4.1.3052.18.1.10.1.1.10
bmsDiffTempEvent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event state of this battery monitor differential temperature
(Very High, High, Normal)."
::= { bmStatusEntry 11 }
--1.3.6.1.4.1.3052.18.1.10.1.1.11
bmsVoltageValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total battery voltage on the string, in volts. Displayed as a
floating point value in format X.X. -999.0 means this is unknown."
::= { bmStatusEntry 12 }
--1.3.6.1.4.1.3052.18.1.10.1.1.12
bmsVoltageEvent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event state of this battery monitor string voltage (Low, Normal, High,
etc.)."
::= { bmStatusEntry 13 }
--1.3.6.1.4.1.3052.18.1.10.1.1.13
bmsDiffVoltValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Differential voltage in volts. Displayed as a floating point value
in format X.X. -999.0 means this is unknown."
::= { bmStatusEntry 14 }
--1.3.6.1.4.1.3052.18.1.10.1.1.14
bmsDiffVoltEvent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event state of this battery monitor differential voltage (Very High,
High, Normal.)"
::= { bmStatusEntry 15 }
--1.3.6.1.4.1.3052.18.1.10.1.1.15
bmsCurrentValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current flow on the string, in amperes. Displayed as a floating point
value in format X.X. A positive value means the battery string is
charging, and a negative value means the battery string is discharging.
-999.0 means this is unknown."
::= { bmStatusEntry 16 }
--1.3.6.1.4.1.3052.18.1.10.1.1.16
bmsChargingCurrentEvent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event state of this battery monitor charging current (Low, Normal,
High, etc.)."
::= { bmStatusEntry 17 }
--1.3.6.1.4.1.3052.18.1.10.1.1.17
bmsDischargingCurrentEvent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event state of this battery monitor discharging current (Low, Normal,
High, etc.)."
::= { bmStatusEntry 18 }
--1.3.6.1.4.1.3052.18.1.10.1.1.18
bmsChargeLevelValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Charge level of the battery string."
::= { bmStatusEntry 19 }
--1.3.6.1.4.1.3052.18.1.10.1.1.19
bmsChargeLevelEvent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event state of this battery monitor charge level (Very Low, Low,
Normal)."
::= { bmStatusEntry 20 }
--1.3.6.1.4.1.3052.18.1.10.1.1.20
bmsJarHealthValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Jar health of the battery string."
::= { bmStatusEntry 21 }
--1.3.6.1.4.1.3052.18.1.10.1.1.21
bmsJarHealthEvent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event state of this battery monitor jar health (Very Low, Low,
Normal)."
::= { bmStatusEntry 22 }
--1.3.6.1.4.1.3052.18.1.10.1.1.22
bmsCombined OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
name`deviceState`deviceStateColorCode`stringState`charge`voltage`temp`health~chargeEventState`chargeColorCode`voltageEventState`voltageColorCode`tempEventState`tempColorCode`healthEventState`healthColorCode`numActiveEvents"
::= { bmStatusEntry 23 }
--1.3.6.1.4.1.3052.18.1.10.1.1.23
bmsJarStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF BMJarStatus
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes per-jar attributes of a battery monitor:
1. voltage
2. temperature."
::= { batteryMonitorStatus 2 }
--1.3.6.1.4.1.3052.18.1.10.2
bmJarStatusEntry OBJECT-TYPE
SYNTAX BMJarStatus
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for battery monitor jar status table. Note this table uses
2 SNMP indexes: the first for which battery monitor and the second for
which jar."
INDEX { bmjsIndexBM, bmjsIndexJar }
::= { bmsJarStatusTable 1 }
--1.3.6.1.4.1.3052.18.1.10.2.1
bmjsIndexBM OBJECT-TYPE
SYNTAX Integer32 (1..9)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the index that refers to which battery monitor."
::= { bmJarStatusEntry 1 }
--1.3.6.1.4.1.3052.18.1.10.2.1.1
bmjsIndexJar OBJECT-TYPE
SYNTAX Integer32 (1..12)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the index that refers to which jar."
::= { bmJarStatusEntry 2 }
--1.3.6.1.4.1.3052.18.1.10.2.1.2
bmjsVoltageValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Voltage of individual battery cell. This is a floating point value
in format X.X. -999.0 means this is unknown."
::= { bmJarStatusEntry 3 }
--1.3.6.1.4.1.3052.18.1.10.2.1.3
bmjsTempValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature of individual battery jar. This is a floating point
value. -999.0 means unknown."
::= { bmJarStatusEntry 4 }
--1.3.6.1.4.1.3052.18.1.10.2.1.4
bmjsAdmittanceValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell admittance of individual jar. This is an integer value.
-999 means unknown."
::= { bmJarStatusEntry 5 }
--1.3.6.1.4.1.3052.18.1.10.2.1.5
bmjsAdmittanceChangeValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percent change of cell admittance of individual jar. This is an
integer value."
::= { bmJarStatusEntry 6 }
--1.3.6.1.4.1.3052.18.1.10.2.1.6
--***************************************************************************************
--EventSensor Basics Section 2.1
--***************************************************************************************
esNumberEventSensors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of EventSensors recognized by the unit,
including the internal EventSensor.
Range: 1-17"
::= { eventSensorBasics 1 }
--1.3.6.1.4.1.3052.18.2.1.1
esTable OBJECT-TYPE
SYNTAX SEQUENCE OF ESExist
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of what EventSensors are attached to the unit,
including the internal EventSensor"
::= { eventSensorBasics 2 }
--1.3.6.1.4.1.3052.18.2.1.2
esEntry OBJECT-TYPE
SYNTAX ESExist
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry for EventSensor table"
INDEX { esIndex }
::= { esTable 1 }
--1.3.6.1.4.1.3052.18.2.1.2.1
esIndex OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This number refers to an EventSensor; it has the
same meaning as the esIndexES object (see above),
except that this object is used only within the
esTable branch.
This object's allowable values are 1 through 16,
and 200. 200 always refers to the EventSensor
inside the unit. 1 through 16 refer to additional
attached EventSensors.
The number corresponding to an EventSensor is
determined by the user at the initial configuration
time. If there is an internal sensor in the unit,
it will always be the first item in the Sensor
Events setup menu.
For example, if a new EventSensor is configured as
the 2nd entry AFTER the internal EventSensor (if
one exists) in the Sensor Events Setup Menu, then
that EventSensor will be known from then on as
EventSensor 2. All point indeces with esIndex=2
will now refer to that particular EventSensor.
"
::= { esEntry 1 }
--1.3.6.1.4.1.3052.18.2.1.2.1.1
esName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the EventSensor"
::= { esEntry 2 }
--1.3.6.1.4.1.3052.18.2.1.2.1.2
esID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The factory-assigned ID of the EventSensor"
::= { esEntry 3 }
--1.3.6.1.4.1.3052.18.2.1.2.1.3
esNumberTempSensors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of temperature sensors on the EventSensor"
::= { esEntry 4 }
--1.3.6.1.4.1.3052.18.2.1.2.1.4
esTempReportingMode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of how temperature values should
be interpreted."
::= { esEntry 5 }
--1.3.6.1.4.1.3052.18.2.1.2.1.5
esNumberCCs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of contact closures on the EventSensor."
::= { esEntry 6 }
--1.3.6.1.4.1.3052.18.2.1.2.1.6
esCCReportingMode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of how CC values should be interpreted."
::= { esEntry 7 }
--1.3.6.1.4.1.3052.18.2.1.2.1.7
esNumberHumidSensors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of humidity sensors on the EventSensor."
::= { esEntry 8 }
--1.3.6.1.4.1.3052.18.2.1.2.1.8
esHumidReportingMode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of how humidity sensor values should be
interpreted."
::= { esEntry 9 }
--1.3.6.1.4.1.3052.18.2.1.2.1.9
esNumberNoiseSensors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of noise sensors on the EventSensor."
::= { esEntry 10 }
--1.3.6.1.4.1.3052.18.2.1.2.1.10
esNoiseReportingMode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of how noise sensor values should be
interpreted."
::= { esEntry 11 }
--1.3.6.1.4.1.3052.18.2.1.2.1.11
esNumberAirflowSensors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of airflow sensors on the EventSensor."
::= { esEntry 12 }
--1.3.6.1.4.1.3052.18.2.1.2.1.12
esAirflowReportingMode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of how airflow sensor values should be
interpreted."
::= { esEntry 13 }
--1.3.6.1.4.1.3052.18.2.1.2.1.13
esNumberAnalog OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of analog inputs on the EventSensor."
::= { esEntry 14 }
--1.3.6.1.4.1.3052.18.2.1.2.1.14
esAnalogReportingMode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of how analog input values should be
interpreted."
::= { esEntry 15 }
--1.3.6.1.4.1.3052.18.2.1.2.1.15
esNumberOutputs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of outputs (relay or power) on the EventSensor"
::= { esEntry 16 }
--1.3.6.1.4.1.3052.18.2.1.2.1.16
esOutputReportingMode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of how output values should be interpreted."
::= { esEntry 17 }
--1.3.6.1.4.1.3052.18.2.1.2.1.17
esTempCombinedStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
name`value`scale`eventState`eventColorCode"
::= { esEntry 18 }
--1.3.6.1.4.1.3052.18.2.1.2.1.18
esCCCombinedStatusBlock1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
numInBlock~name1`value1`eventColorCode1`alias1~name2`value2`eventColorCode2`alias2~...name8`value8`eventColorCode8`alias8"
::= { esEntry 19 }
--1.3.6.1.4.1.3052.18.2.1.2.1.19
esCCCombinedStatusBlock2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
numInBlock~name9`value9`eventColorCode9`alias9~name10`value10`eventColorCode10`alias10~...name16`value16`eventColorCode16`alias16"
::= { esEntry 20 }
--1.3.6.1.4.1.3052.18.2.1.2.1.20
esCCCombinedStatusBlock3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
numInBlock~name17`value17`eventColorCode17`alias17~name18`value18`eventColorCode18`alias18~...name24`value24`eventColorCode24`alias24"
::= { esEntry 21 }
--1.3.6.1.4.1.3052.18.2.1.2.1.21
esCCCombinedStatusBlock4 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
numInBlock~name25`value25`eventColorCode25`alias25~name26`value26`eventColorCode26`alias26~...name32`value32`eventColorCode32`alias32"
::= { esEntry 22 }
--1.3.6.1.4.1.3052.18.2.1.2.1.22
esCCCombinedStatusBlock5 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
numInBlock~name33`value33`eventColorCode33`alias33~name34`value34`eventColorCode34`alias35~...name40`value40`eventColorCode40`alias40"
::= { esEntry 23 }
--1.3.6.1.4.1.3052.18.2.1.2.1.23
esCCCombinedStatusBlock6 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
numInBlock~name41`value41`eventColorCode41`alias41~name42`value42`eventColorCode42`alias43~...name48`value48`eventColorCode48`alias48"
::= { esEntry 24 }
--1.3.6.1.4.1.3052.18.2.1.2.1.24
esCCCombinedStatusBlock7 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
numInBlock~name49`value49`eventColorCode49`alias49~name50`value50`eventColorCode50`alias50~...name56`value56`eventColorCode56`alias56"
::= { esEntry 25 }
--1.3.6.1.4.1.3052.18.2.1.2.1.25
esCCCombinedStatusBlock8 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
numInBlock~name57`value57`eventColorCode57`alias57~name57`value57`eventColorCode564`alias57~...name64`value64`eventColorCode64`alias64"
::= { esEntry 26 }
--1.3.6.1.4.1.3052.18.2.1.2.1.26
esHumidCombinedStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
name`value`eventState`eventColorCode"
::= { esEntry 27 }
--1.3.6.1.4.1.3052.18.2.1.2.1.27
esAnalogCombinedStatusBlock1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
numInBlock~name1`value1`units1`eventState`eventColorCode1~name2`value2`units2`eventState`eventColorCode2~..."
::= { esEntry 28 }
--1.3.6.1.4.1.3052.18.2.1.2.1.28
esAnalogCombinedStatusBlock2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
numInBlock~name9`value9`units9`eventState9`eventColorCode9~..."
::= { esEntry 29 }
--1.3.6.1.4.1.3052.18.2.1.2.1.29
esAnalogCombinedStatusBlock3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
::= { esEntry 30 }
--1.3.6.1.4.1.3052.18.2.1.2.1.31
esAnalogCombinedStatusBlock4 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
::= { esEntry 31 }
--1.3.6.1.4.1.3052.18.2.1.2.1.31
esAnalogCombinedStatusBlock5 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
::= { esEntry 32 }
--1.3.6.1.4.1.3052.18.2.1.2.1.32
esAnalogCombinedStatusBlock6 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
::= { esEntry 33 }
--1.3.6.1.4.1.3052.18.2.1.2.1.33
esOutputCombinedStatusBlock1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..."
::= { esEntry 34 }
--1.3.6.1.4.1.3052.18.2.1.2.1.34
esOutputCombinedStatusBlock2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Combined status string intended to be parsed by NMS:
numInBlock`namex`valuex`aliasx~namey`valuey`aliasy~...namez`valuez`aliasz"
::= { esEntry 35 }
--1.3.6.1.4.1.3052.18.2.1.2.1.35
esNewSensors OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"String representing the number of new (attached but unconfigured) EventSensors"
::= { eventSensorBasics 3 }
--1.3.6.1.4.1.3052.18.2.1.3
--***************************************************************************************
--EventSensor Point Config Section 2.2
--***************************************************************************************
esPointConfigTempTable OBJECT-TYPE
SYNTAX SEQUENCE OF ESPointConfigTemp
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes 3 basic attributes of temperature
sensor points. A point is a particular sensor on an
EventSensor. The 3 point attributes organizes in this table
are:
1. the configuration item (e.g., enable, name, etc.)
2. the eventsensor on which this point resides
3. the point number (always 1 for temp sensors)
Points are referenced by a point config index. The point
config index is a string of 2 numbers separated by periods.
It contains all the information necessary for getting a
piece of data off an event sensor within the context of this
emperature point config table ; namely, which EventSensor,
and which sensor (a.k.a. point) (always 1 for temperature
sensors).
"
::= { eventSensorPointConfig 1 }
--1.3.6.1.4.1.3052.18.2.2.1
esPointConfigTempEntry OBJECT-TYPE
SYNTAX ESPointConfigTemp
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for EventSensor point config temperature table"
INDEX { espcTempIndexES, espcTempIndexPoint }
::= { esPointConfigTempTable 1 }
--1.3.6.1.4.1.3052.18.2.2.1.1
espcTempIndexES OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that refers to an
EventSensor.
The point config index is a string of 2 numbers separated
by a period. It contains all the information
necessary for getting a piece of data off an event
sensor within the the context of the eventsensor point
config temperature table; namely, which EventSensor,
and which sensor (a.k.a. point).
This object's allowable values are 1 through 16,
and 200. 200 always refers to the EventSensor
inside the unit. 1 through 16 refer to additional
attached EventSensors.
The number corresponding to an EventSensor is
determined by the user at the initial configuration
time. If there is an internal sensor in the unit,
it will always be the first item in the Sensor
Events setup menu.
For example, if a new EventSensor is configured as
the 2nd entry AFTER the internal EventSensor (if
one exists) in the Sensor Events Setup Menu, then
that EventSensor will be known from then on as
EventSensor 2. All point indeces with esIndexES=2
will now refer to that particular EventSensor.
"
::= { esPointConfigTempEntry 1 }
--1.3.6.1.4.1.3052.18.2.2.1.1.1
espcTempIndexPoint OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that delineates which
sensor on the EventSensor.
So this combined with espcTempIndexES (which EventSensor)
uniquely defines each point attached to a unit within the
context of temperature point configuration."
::= { esPointConfigTempEntry 2 }
--1.3.6.1.4.1.3052.18.2.2.1.1.2
espcTempEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable this temperature sensor"
::= { esPointConfigTempEntry 3 }
--1.3.6.1.4.1.3052.18.2.2.1.1.3
espcTempScale OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Scale (C/F) for this temperature sensor"
::= { esPointConfigTempEntry 4 }
--1.3.6.1.4.1.3052.18.2.2.1.1.4
espcTempDeadband OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Deadband for this temperature sensor (in floating-point format)"
::= { esPointConfigTempEntry 5 }
--1.3.6.1.4.1.3052.18.2.2.1.1.5
espcTempVHighTemp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high temperature event threshold for this temperature
sensor (in floating-point format)"
::= { esPointConfigTempEntry 6 }
--1.3.6.1.4.1.3052.18.2.2.1.1.6
espcTempVHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high temperature event actions for this temperature
sensor"
::= { esPointConfigTempEntry 7 }
--1.3.6.1.4.1.3052.18.2.2.1.1.7
espcTempVHighTrapnum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high temperature event trap number for this
temperature sensor"
::= { esPointConfigTempEntry 8 }
--1.3.6.1.4.1.3052.18.2.2.1.1.8
espcTempVHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high temperature event class for this temperature
sensor"
::= { esPointConfigTempEntry 9 }
--1.3.6.1.4.1.3052.18.2.2.1.1.9
espcTempHighTemp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High temperature event threshold for this temperature
sensor (in floating-point format)"
::= { esPointConfigTempEntry 10 }
--1.3.6.1.4.1.3052.18.2.2.1.1.10
espcTempHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High temperature event actions for this temperature sensor"
::= { esPointConfigTempEntry 11 }
--1.3.6.1.4.1.3052.18.2.2.1.1.11
espcTempHighTrapnum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High temperature event trap number for this temperature
sensor"
::= { esPointConfigTempEntry 12 }
--1.3.6.1.4.1.3052.18.2.2.1.1.12
espcTempHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High temperature event class for this temperature sensor"
::= { esPointConfigTempEntry 13 }
--1.3.6.1.4.1.3052.18.2.2.1.1.13
espcTempNormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return-to-normal event actions for this temperature sensor"
::= { esPointConfigTempEntry 14 }
--1.3.6.1.4.1.3052.18.2.2.1.1.14
espcTempNormalTrapnum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return-to-normal event trap number for this temperature
sensor"
::= { esPointConfigTempEntry 15 }
--1.3.6.1.4.1.3052.18.2.2.1.1.15
espcTempNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return-to-normal event class for this temperature sensor"
::= { esPointConfigTempEntry 16 }
--1.3.6.1.4.1.3052.18.2.2.1.1.16
espcTempLowTemp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low temperature event threshold for this temperature sensor
(in floating-point format)"
::= { esPointConfigTempEntry 17 }
--1.3.6.1.4.1.3052.18.2.2.1.1.17
espcTempLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low temperature event actions for this temperature sensor"
::= { esPointConfigTempEntry 18 }
--1.3.6.1.4.1.3052.18.2.2.1.1.18
espcTempLowTrapnum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low temperature event trap number for this temperature
sensor"
::= { esPointConfigTempEntry 19 }
--1.3.6.1.4.1.3052.18.2.2.1.1.19
espcTempLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low temperature event class for this temperature sensor"
::= { esPointConfigTempEntry 20 }
--1.3.6.1.4.1.3052.18.2.2.1.1.20
espcTempVLowTemp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very Low temperature event threshold for this temperature
sensor (in floating-point format)"
::= { esPointConfigTempEntry 21 }
--1.3.6.1.4.1.3052.18.2.2.1.1.21
espcTempVLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very Low temperature event actions for this temperature
sensor"
::= { esPointConfigTempEntry 22 }
--1.3.6.1.4.1.3052.18.2.2.1.1.22
espcTempVLowTrapnum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very Low temperature event trap number for this temperature
sensor"
::= { esPointConfigTempEntry 23 }
--1.3.6.1.4.1.3052.18.2.2.1.1.23
espcTempVLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very Low temperature event class for this temperature sensor"
::= { esPointConfigTempEntry 24 }
--1.3.6.1.4.1.3052.18.2.2.1.1.24
esPointConfigCCTable OBJECT-TYPE
SYNTAX SEQUENCE OF ESPointConfigCC
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes 3 basic attributes of contact closure
points. A point is a particular sensor on an EventSensor.
The 3 point attributes organizes in this table are:
1. the configuration item (e.g., enable, name, etc.)
2. the eventsensor on which this point resides
3. the point number
Points are referenced by a point config index. The point
config index is a string of 2 numbers separated by a period.
It contains all the information necessary for getting a piece
of data off an event sensor within the context of this
contact closure point config table ; namely, which
EventSensor and which sensor.
"
::= { eventSensorPointConfig 2 }
--1.3.6.1.4.1.3052.18.2.2.2
esPointConfigCCEntry OBJECT-TYPE
SYNTAX ESPointConfigCC
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for EventSensor point config contact closure table"
INDEX { espcCCIndexES, espcCCIndexPoint }
::= { esPointConfigCCTable 1 }
--1.3.6.1.4.1.3052.18.2.2.2.1
espcCCIndexES OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that refers to an
EventSensor.
The point config index is a string of 2 numbers separated
by a period. It contains all the information
necessary for getting a piece of data off an event
sensor within the the context of the eventsensor point
config contact closure table; namely, which EventSensor
and which sensor (a.k.a. point).
This object's allowable values are 1 through 16,
and 200. 200 always refers to the EventSensor
inside the unit. 1 through 16 refer to additional
attached EventSensors.
"
::= { esPointConfigCCEntry 1 }
--1.3.6.1.4.1.3052.18.2.2.2.1.1
espcCCIndexPoint OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that delineates which
sensor on the EventSensor.
So this combined with espcCCIndexES (which EventSensor)
uniquely defines each point attached to a unit within the
context of contact closure point configuration."
::= { esPointConfigCCEntry 2 }
--1.3.6.1.4.1.3052.18.2.2.2.1.2
espcCCEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable for this contact closure"
::= { esPointConfigCCEntry 3 }
--1.3.6.1.4.1.3052.18.2.2.2.1.3
espcCCName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name for this contact closure"
::= { esPointConfigCCEntry 4 }
--1.3.6.1.4.1.3052.18.2.2.2.1.4
espcCCEventState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Event state for this contact closure"
::= { esPointConfigCCEntry 5 }
--1.3.6.1.4.1.3052.18.2.2.2.1.5
espcCCThreshold OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Event threshold (seconds) for this contact closure"
::= { esPointConfigCCEntry 6 }
--1.3.6.1.4.1.3052.18.2.2.2.1.6
espcCCEventActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Event actions for this contact closure"
::= { esPointConfigCCEntry 7 }
--1.3.6.1.4.1.3052.18.2.2.2.1.7
espcCCEventTrapnum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Event trap number for this contact closure"
::= { esPointConfigCCEntry 8 }
--1.3.6.1.4.1.3052.18.2.2.2.1.8
espcCCEventClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Event class for this contact closure"
::= { esPointConfigCCEntry 9 }
--1.3.6.1.4.1.3052.18.2.2.2.1.9
espcCCNormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return-to-normal actions for this contact closure"
::= { esPointConfigCCEntry 10 }
--1.3.6.1.4.1.3052.18.2.2.2.1.10
espcCCNormalTrapnum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return-to-normal trap number for this contact closure"
::= { esPointConfigCCEntry 11 }
--1.3.6.1.4.1.3052.18.2.2.2.1.11
espcCCNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return-to-normal class for this contact closure"
::= { esPointConfigCCEntry 12 }
--1.3.6.1.4.1.3052.18.2.2.2.1.12
espcCCAlarmAlias OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Event alias for this contact closure"
::= { esPointConfigCCEntry 13 }
--1.3.6.1.4.1.3052.18.2.2.2.1.13
espcCCNormalAlias OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return-to-normal alias for this contact closure"
::= { esPointConfigCCEntry 14 }
--1.3.6.1.4.1.3052.18.2.2.2.1.14
espcCCNormalThreshold OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Event threshold (seconds) for this contact closure to return to normal"
::= { esPointConfigCCEntry 15 }
--1.3.6.1.4.1.3052.18.2.2.2.1.15
espcCCOverrideGlobalReminder OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Override global reminder interval (evReminderInterval) for this CC."
::= { esPointConfigCCEntry 16 }
--1.3.6.1.4.1.3052.18.2.2.2.1.16
espcCCReminderInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Individual reminder interval for this CC, applicable when the global
reminder is overriden."
::= { esPointConfigCCEntry 17 }
--1.3.6.1.4.1.3052.18.2.2.2.1.17
esPointConfigHumidTable OBJECT-TYPE
SYNTAX SEQUENCE OF ESPointConfigHumid
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes 3 basic attributes of humidity points.
A point is a particular sensor on an EventSensor. The 3
point attributes organizes in this table are:
1. the configuration item (e.g., enable, name, etc.)
2. the eventsensor on which this point resides
3. the point number (always 1 for humidity sensors)
Points are referenced by a point config index. The point
config index is a string of 2 numbers separated by a period.
It contains all the information necessary for getting a piece
of data off an event sensor within the context of this
humidity point config table ; namely, which EventSensor and
which sensor.
"
::= { eventSensorPointConfig 3 }
--1.3.6.1.4.1.3052.18.2.2.3
esPointConfigHumidEntry OBJECT-TYPE
SYNTAX ESPointConfigHumid
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for EventSensor point config humidity table"
INDEX { espcHumidIndexES, espcHumidIndexPoint }
::= { esPointConfigHumidTable 1 }
--1.3.6.1.4.1.3052.18.2.2.3.1
espcHumidIndexES OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that refers to an
EventSensor.
The point config index is a string of 2 numbers separated
by a period. It contains all the information
necessary for getting a piece of data off an event
sensor within the the context of the eventsensor point
config contact closure table; namely, which EventSensor
and which sensor (a.k.a. point).
This object's allowable values are 1 through 16,
and 200. 200 always refers to the EventSensor
inside the unit. 1 through 16 refer to additional
attached EventSensors.
"
::= { esPointConfigHumidEntry 1 }
--1.3.6.1.4.1.3052.18.2.2.3.1.1
espcHumidIndexPoint OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that delineates which
sensor on the EventSensor.
So this combined with espcHumidIndexES (which EventSensor)
uniquely defines each point attached to a unit within the
context of contact closure point configuration."
::= { esPointConfigHumidEntry 2 }
--1.3.6.1.4.1.3052.18.2.2.3.1.2
espcHumidEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable for this humidity sensor"
::= { esPointConfigHumidEntry 3 }
--1.3.6.1.4.1.3052.18.2.2.3.1.3
espcHumidDeadband OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Deadband for this humidity sensor"
::= { esPointConfigHumidEntry 4 }
--1.3.6.1.4.1.3052.18.2.2.3.1.4
espcHumidVHighHumid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event threshold for this humidity sensor"
::= { esPointConfigHumidEntry 5 }
--1.3.6.1.4.1.3052.18.2.2.3.1.5
espcHumidVHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event actions for this humidity sensor"
::= { esPointConfigHumidEntry 6 }
--1.3.6.1.4.1.3052.18.2.2.3.1.6
espcHumidVHighTrapnum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event trap number for this humidity sensor"
::= { esPointConfigHumidEntry 7 }
--1.3.6.1.4.1.3052.18.2.2.3.1.7
espcHumidVHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event class for this humidity sensor"
::= { esPointConfigHumidEntry 8 }
--1.3.6.1.4.1.3052.18.2.2.3.1.8
espcHumidHighHumid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event threshold for this humidity sensor"
::= { esPointConfigHumidEntry 9 }
--1.3.6.1.4.1.3052.18.2.2.3.1.9
espcHumidHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event actions for this humidity sensor"
::= { esPointConfigHumidEntry 10 }
--1.3.6.1.4.1.3052.18.2.2.3.1.10
espcHumidHighTrapnum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event trap number for this humidity sensor"
::= { esPointConfigHumidEntry 11 }
--1.3.6.1.4.1.3052.18.2.2.3.1.11
espcHumidHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event class for this humidity sensor"
::= { esPointConfigHumidEntry 12 }
--1.3.6.1.4.1.3052.18.2.2.3.1.12
espcHumidNormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return-to-normal actions for this humidity sensor"
::= { esPointConfigHumidEntry 13 }
--1.3.6.1.4.1.3052.18.2.2.3.1.13
espcHumidNormalTrapnum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return-to-normal trap number for this humidity sensor"
::= { esPointConfigHumidEntry 14 }
--1.3.6.1.4.1.3052.18.2.2.3.1.14
espcHumidNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return-to-normal class for this humidity sensor"
::= { esPointConfigHumidEntry 15 }
--1.3.6.1.4.1.3052.18.2.2.3.1.15
espcHumidLowHumid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event threshold for this humidity sensor"
::= { esPointConfigHumidEntry 16 }
--1.3.6.1.4.1.3052.18.2.2.3.1.16
espcHumidLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event actions for this humidity sensor"
::= { esPointConfigHumidEntry 17 }
--1.3.6.1.4.1.3052.18.2.2.3.1.17
espcHumidLowTrapnum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event trap number for this humidity sensor"
::= { esPointConfigHumidEntry 18 }
--1.3.6.1.4.1.3052.18.2.2.3.1.18
espcHumidLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event class for this humidity sensor"
::= { esPointConfigHumidEntry 19 }
--1.3.6.1.4.1.3052.18.2.2.3.1.19
espcHumidVLowHumid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event threshold for this humidity sensor"
::= { esPointConfigHumidEntry 20 }
--1.3.6.1.4.1.3052.18.2.2.3.1.20
espcHumidVLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event actions for this humidity sensor"
::= { esPointConfigHumidEntry 21 }
--1.3.6.1.4.1.3052.18.2.2.3.1.21
espcHumidVLowTrapnum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event trap number for this humidity sensor"
::= { esPointConfigHumidEntry 22 }
--1.3.6.1.4.1.3052.18.2.2.3.1.22
espcHumidVLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event class for this humidity sensor"
::= { esPointConfigHumidEntry 23 }
--1.3.6.1.4.1.3052.18.2.2.3.1.23
esPointConfigAITable OBJECT-TYPE
SYNTAX SEQUENCE OF ESPointConfigAnalogInput
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes 3 basic attributes of analog input
points. A point is a particular sensor on an EventSensor.
The 3 point attributes organizes in this table are:
1. the configuration item (e.g., enable, name, etc.)
2. the eventsensor on which this point resides
3. the point number
Points are referenced by a point config index. The point
config index is a string of 2 numbers separated by a period.
It contains all the information necessary for getting a
piece of data off an event sensor within the context of this
analog input point config table ; namely, which EventSensor
and which sensor.
"
::= { eventSensorPointConfig 5 }
--1.3.6.1.4.1.3052.18.2.2.5
esPointConfigAIEntry OBJECT-TYPE
SYNTAX ESPointConfigAnalogInput
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for EventSensor point config analog input table"
INDEX { espcHumidIndexES, espcHumidIndexPoint }
::= { esPointConfigAITable 1 }
--1.3.6.1.4.1.3052.18.2.2.5.1
espcAIIndexES OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that refers to an
EventSensor.
The point config index is a string of 2 numbers separated
by a period. It contains all the information
necessary for getting a piece of data off an event
sensor within the the context of the eventsensor point
config contact closure table; namely, which EventSensor
and which sensor (a.k.a. point).
This object's allowable values are 1 through 16,
and 200. 200 always refers to the EventSensor
inside the unit. 1 through 16 refer to additional
attached EventSensors.
"
::= { esPointConfigAIEntry 1 }
--1.3.6.1.4.1.3052.18.2.2.5.1.1
espcAIIndexPoint OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that delineates which
sensor on the EventSensor.
So this combined with espcAIIndexES (which EventSensor)
uniquely defines each point attached to a unit within the
context of contact closure point configuration."
::= { esPointConfigAIEntry 2 }
--1.3.6.1.4.1.3052.18.2.2.5.1.2
espcAIEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF for this analog input sensor"
::= { esPointConfigAIEntry 3 }
--1.3.6.1.4.1.3052.18.2.2.5.1.3
espcAIDeadband OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Deadband for this analog input sensor"
::= { esPointConfigAIEntry 5 }
--1.3.6.1.4.1.3052.18.2.2.5.1.5
espcAIVhighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event threshold (decivolts or tenths of
milliamps) for this analog input sensor"
::= { esPointConfigAIEntry 6 }
--1.3.6.1.4.1.3052.18.2.2.5.1.6
espcAIVhighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event actions for this analog input sensor"
::= { esPointConfigAIEntry 7 }
--1.3.6.1.4.1.3052.18.2.2.5.1.7
espcAIVhighTrapnum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event trap number for this analog input sensor"
::= { esPointConfigAIEntry 8 }
--1.3.6.1.4.1.3052.18.2.2.5.1.8
espcAIVhighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event class for this analog input sensor"
::= { esPointConfigAIEntry 9 }
--1.3.6.1.4.1.3052.18.2.2.5.1.9
espcAIHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event threshold (decivolts or tenths of milliamps) for
this analog input sensor"
::= { esPointConfigAIEntry 10 }
--1.3.6.1.4.1.3052.18.2.2.5.1.10
espcAIHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event actions for this analog input sensor"
::= { esPointConfigAIEntry 11 }
--1.3.6.1.4.1.3052.18.2.2.5.1.11
espcAIHighTrapnum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event trap number for this analog input sensor"
::= { esPointConfigAIEntry 12 }
--1.3.6.1.4.1.3052.18.2.2.5.1.12
espcAIHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event class for this analog input sensor"
::= { esPointConfigAIEntry 13 }
--1.3.6.1.4.1.3052.18.2.2.5.1.13
espcAINormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return-to-normal actions for this analog input sensor"
::= { esPointConfigAIEntry 14 }
--1.3.6.1.4.1.3052.18.2.2.5.1.14
espcAINormalTrapnum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return-to-normal trap number for this analog input sensor"
::= { esPointConfigAIEntry 15 }
--1.3.6.1.4.1.3052.18.2.2.5.1.15
espcAINormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return-to-normal class for this analog input sensor"
::= { esPointConfigAIEntry 16 }
--1.3.6.1.4.1.3052.18.2.2.5.1.16
espcAILowValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event threshold (decivolts or tenths of milliamps) for
this analog input sensor"
::= { esPointConfigAIEntry 17 }
--1.3.6.1.4.1.3052.18.2.2.5.1.17
espcAILowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event actions for this analog input sensor"
::= { esPointConfigAIEntry 18 }
--1.3.6.1.4.1.3052.18.2.2.5.1.18
espcAILowTrapnum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event trap number for this analog input sensor"
::= { esPointConfigAIEntry 19 }
--1.3.6.1.4.1.3052.18.2.2.5.1.19
espcAILowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event class for this analog input sensor"
::= { esPointConfigAIEntry 20 }
--1.3.6.1.4.1.3052.18.2.2.5.1.20
espcAIVlowValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event threshold (decivolts or tenths of milliamps)
for this analog input sensor"
::= { esPointConfigAIEntry 21 }
--1.3.6.1.4.1.3052.18.2.2.5.1.21
espcAIVlowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event actions for this analog input sensor"
::= { esPointConfigAIEntry 22 }
--1.3.6.1.4.1.3052.18.2.2.5.1.22
espcAIVlowTrapnum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event actions for this analog input sensor"
::= { esPointConfigAIEntry 23 }
--1.3.6.1.4.1.3052.18.2.2.5.1.23
espcAIVlowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event class for this analog input sensor"
::= { esPointConfigAIEntry 24 }
--1.3.6.1.4.1.3052.18.2.2.5.1.24
espcAIConvUnitName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Converstion unit name for this analog input sensor"
::= { esPointConfigAIEntry 25 }
--1.3.6.1.4.1.3052.18.2.2.5.1.25
espcAIConvHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Conversion high value for this analog input sensor"
::= { esPointConfigAIEntry 26 }
--1.3.6.1.4.1.3052.18.2.2.5.1.26
espcAIConvHighUnit OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Conversion high unit value for this analog input sensor"
::= { esPointConfigAIEntry 27 }
--1.3.6.1.4.1.3052.18.2.2.5.1.27
espcAIConvLowValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Conversion low value for this analog input sensor"
::= { esPointConfigAIEntry 29 }
--1.3.6.1.4.1.3052.18.2.2.5.1.29
espcAIConvLowUnit OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Conversion unit low unit value for this analog input sensor"
::= { esPointConfigAIEntry 30 }
--1.3.6.1.4.1.3052.18.2.2.5.1.30
espcAIDisplayFormat OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Analog input display format"
::= { esPointConfigAIEntry 32 }
--1.3.6.1.4.1.3052.18.2.2.5.1.32
esPointConfigOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF ESPointConfigOutput
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes configuration items for output
points. A point is a particular sensor on an EventSensor.
The 3 point attributes organized in this table are:
1. the configuration item (e.g., enable, name, etc.)
2. the eventsensor on which this point resides
3. the point number
Points are referenced by a point config index. The point
config index is a string of 2 numbers separated by a period.
It contains all the information necessary for getting a
piece of data off an event sensor within the context of this
output config table ; namely, which EventSensor
and which sensor.
"
::= { eventSensorPointConfig 6 }
--1.3.6.1.4.1.3052.18.2.2.6
esPointConfigOutputEntry OBJECT-TYPE
SYNTAX ESPointConfigOutput
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for EventSensor point config output table"
INDEX { espcOutputIndexES, espcOutputIndexPoint }
::= { esPointConfigOutputTable 1 }
--1.3.6.1.4.1.3052.18.2.2.6.1
espcOutputIndexES OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that refers to an
EventSensor.
The point config index is a string of 2 numbers separated
by a period. It contains all the information
necessary for getting a piece of data off an event
sensor within the the context of the eventsensor point
config contact closure table; namely, which EventSensor
and which sensor (a.k.a. point).
This object's allowable values are 1 through 16,
and 200. 200 always refers to the EventSensor
inside the unit. 1 through 16 refer to additional
attached EventSensors.
"
::= { esPointConfigOutputEntry 1 }
--1.3.6.1.4.1.3052.18.2.2.6.1.1
espcOutputIndexPoint OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part of the point index that delineates which
sensor on the EventSensor.
So this combined with espcOutputIndexES (which EventSensor)
uniquely defines each point attached to a unit within the
context of output point configuration."
::= { esPointConfigOutputEntry 2 }
--1.3.6.1.4.1.3052.18.2.2.6.1.2
espcOutputEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables the output event for this output. This has no effect
on whether the relay changes state, only on whether a state change
triggers an event."
::= { esPointConfigOutputEntry 3 }
--1.3.6.1.4.1.3052.18.2.2.6.1.3
espcOutputActiveState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Which state is considered the active state: energized/de-energized."
::= { esPointConfigOutputEntry 4 }
--1.3.6.1.4.1.3052.18.2.2.6.1.4
espcOutputType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Output type: RELAY, POWER, SSR, TTL."
::= { esPointConfigOutputEntry 5 }
--1.3.6.1.4.1.3052.18.2.2.6.1.5
espcOutputAliasValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Output alias corresponding to its event state."
::= { esPointConfigOutputEntry 6 }
--1.3.6.1.4.1.3052.18.2.2.6.1.6
espcOutputAliasColor OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Output color corresponding to its event state."
::= { esPointConfigOutputEntry 7 }
--1.3.6.1.4.1.3052.18.2.2.6.1.7
espcOutputActiveAlias OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Alias for the output active state."
::= { esPointConfigOutputEntry 10 }
--1.3.6.1.4.1.3052.18.2.2.6.1.10
espcOutputActiveColor OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Output color (as rendered in the web UI, in RGB hex format) corresponding
to the output active state."
::= { esPointConfigOutputEntry 11 }
--1.3.6.1.4.1.3052.18.2.2.6.1.11
espcOutputActiveActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for the output active event."
::= { esPointConfigOutputEntry 12 }
--1.3.6.1.4.1.3052.18.2.2.6.1.12
espcOutputActiveTrapnum OBJECT-TYPE
SYNTAX Integer32 (150..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for the output active event."
::= { esPointConfigOutputEntry 13 }
--1.3.6.1.4.1.3052.18.2.2.6.1.13
espcOutputActiveClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class (severity) for the output active event."
::= { esPointConfigOutputEntry 14 }
--1.3.6.1.4.1.3052.18.2.2.6.1.14
espcOutputInactiveAlias OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Alias for the output inactive state."
::= { esPointConfigOutputEntry 20 }
--1.3.6.1.4.1.3052.18.2.2.6.1.20
espcOutputInactiveColor OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Output color (as rendered in the web UI, in RGB hex format) corresponding
to the output inactive state."
::= { esPointConfigOutputEntry 21 }
--1.3.6.1.4.1.3052.18.2.2.6.1.21
espcOutputInactiveActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for the output inactive event."
::= { esPointConfigOutputEntry 22 }
--1.3.6.1.4.1.3052.18.2.2.6.1.22
espcOutputInactiveTrapnum OBJECT-TYPE
SYNTAX Integer32 (150..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for the output inactive event."
::= { esPointConfigOutputEntry 23 }
--1.3.6.1.4.1.3052.18.2.2.6.1.23
espcOutputInactiveClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class (severity) for the output inactive event."
::= { esPointConfigOutputEntry 24 }
--1.3.6.1.4.1.3052.18.2.2.6.1.24
--***************************************************************************************
--Serial Port Section 2.3
--***************************************************************************************
numberPorts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of RS-232 ports found.
Range: 2 or 4"
::= { serialPorts 1 }
--1.3.6.1.4.1.3052.18.2.3.1
portConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Port config table"
::= { serialPorts 2 }
--1.3.6.1.4.1.3052.18.2.3.2
portConfigEntry OBJECT-TYPE
SYNTAX PortConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Port config entry"
INDEX { portConfigIndex }
::= { portConfigTable 1 }
--1.3.6.1.4.1.3052.18.2.3.2.1
portConfigIndex OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for ports"
::= { portConfigEntry 1 }
--1.3.6.1.4.1.3052.18.2.3.2.1.1
portConfigBaud OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Baud rate, 19200, 9600, etc."
::= { portConfigEntry 2 }
--1.3.6.1.4.1.3052.18.2.3.2.1.2
portConfigDataFormat OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Value representing word length, parity, and
stop bits: 0=8N1, 1=7E1, 2=7O1, 3=7N1, 4=8O2"
::= { portConfigEntry 3 }
--1.3.6.1.4.1.3052.18.2.3.2.1.3
portConfigStripPtOutputLfs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Strip passthrough LFs sent to device on this port:
1=yes, 0=no."
::= { portConfigEntry 4 }
--1.3.6.1.4.1.3052.18.2.3.2.1.4
portConfigStripPtInputLfs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Strip passthrough LFs received from device on this
port: 1=yes, 0=no."
::= { portConfigEntry 5 }
--1.3.6.1.4.1.3052.18.2.3.2.1.5
portConfigId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The text identifer for the port"
::= { portConfigEntry 27 }
--1.3.6.1.4.1.3052.18.2.3.2.1.27
portConfigMode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mode of the serial port."
::= { portConfigEntry 28 }
--1.3.6.1.4.1.3052.18.2.3.2.1.28
portConfigHsk OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Handshaking mode of the serial port."
::= { portConfigEntry 29 }
--1.3.6.1.4.1.3052.18.2.3.2.1.29
--***************************************************************************************
--Network Section 2.4
--***************************************************************************************
eth1Mode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mode of the Ethernet1 interface: STATIC,DHCP,VLAN"
::= { ethernet1 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.1
eth1Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 IP address"
::= { ethernet1 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.2
eth1SubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 subnet mask"
::= { ethernet1 3 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.3
eth1Router OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 router"
::= { ethernet1 4 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.4
-- Ethernet1 VLAN1
eth1VLAN1ID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN1 ID"
::= { eth1VLAN1 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.1.1
eth1VLAN1Priority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN1 priority"
::= { eth1VLAN1 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.1.2
eth1VLAN1Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN1 IP address"
::= { eth1VLAN1 3 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.1.3
eth1VLAN1SubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN1 subnet mask"
::= { eth1VLAN1 4 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.1.4
eth1VLAN1Router OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN1 router"
::= { eth1VLAN1 5 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.1.5
-- Ethernet1 VLAN2
eth1VLAN2ID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN2 ID"
::= { eth1VLAN2 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.2.1
eth1VLAN2Priority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN2 priority"
::= { eth1VLAN2 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.2.2
eth1VLAN2Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN2 IP address"
::= { eth1VLAN2 3 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.2.3
eth1VLAN2SubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN2 subnet mask"
::= { eth1VLAN2 4 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.2.4
eth1VLAN2Router OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN2 router"
::= { eth1VLAN2 5 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.2.5
-- Ethernet1 VLAN3
eth1VLAN3ID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN3 ID"
::= { eth1VLAN3 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.3.1
eth1VLAN3Priority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN3 priority"
::= { eth1VLAN3 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.3.2
eth1VLAN3Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN3 IP address"
::= { eth1VLAN3 3 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.3.3
eth1VLAN3SubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN3 subnet mask"
::= { eth1VLAN3 4 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.3.4
eth1VLAN3Router OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN3 router"
::= { eth1VLAN3 5 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.3.5
-- Ethernet1 VLAN4
eth1VLAN4ID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN4 ID"
::= { eth1VLAN4 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.4.1
eth1VLAN4Priority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN4 priority"
::= { eth1VLAN4 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.4.2
eth1VLAN4Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN4 IP address"
::= { eth1VLAN4 3 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.4.3
eth1VLAN4SubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN4 subnet mask"
::= { eth1VLAN4 4 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.4.4
eth1VLAN4Router OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN4 router"
::= { eth1VLAN4 5 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.4.5
-- Ethernet1 VLAN5
eth1VLAN5ID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN5 ID"
::= { eth1VLAN5 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.5.1
eth1VLAN5Priority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN5 priority"
::= { eth1VLAN5 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.5.2
eth1VLAN5Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN5 IP address"
::= { eth1VLAN5 3 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.5.3
eth1VLAN5SubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN5 subnet mask"
::= { eth1VLAN5 4 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.5.4
eth1VLAN5Router OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN5 router"
::= { eth1VLAN5 5 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.5.5
-- Ethernet1 VLAN6
eth1VLAN6ID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN6 ID"
::= { eth1VLAN6 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.6.1
eth1VLAN6Priority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN6 priority"
::= { eth1VLAN6 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.6.2
eth1VLAN6Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN6 IP address"
::= { eth1VLAN6 3 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.6.3
eth1VLAN6SubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN6 subnet mask"
::= { eth1VLAN6 4 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.6.4
eth1VLAN6Router OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet1 VLAN6 router"
::= { eth1VLAN6 5 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.5.6.5
eth1MAC OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ethernet1 MAC"
::= { ethernet1 6 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.6
eth1IPv6Mode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls IPv6 operation for this Ethernet interface."
::= { eth1IPv6 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.7.1
eth1IPv6StaticAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"he static IPv6 address to use for this interface when in
operating in STATIC mode."
::= { eth1IPv6Static 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.7.2.1
eth1IPv6StaticRouter OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv6 router to engage as the default router when this
interface operates in STATIC mode."
::= { eth1IPv6Static 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.7.2.1
eth1IPv6AutoAddress1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"One of the automatically-acquired IPv6 addresses."
::= { eth1IPv6Auto 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.7.3.1
eth1IPv6AutoAddress2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"One of the automatically-acquired IPv6 addresses."
::= { eth1IPv6Auto 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.7.3.2
eth1IPv6AutoAddress3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"One of the automatically-acquired IPv6 addresses."
::= { eth1IPv6Auto 3 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.7.3.3
eth1IPv6AutoAddress4 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"One of the automatically-acquired IPv6 addresses."
::= { eth1IPv6Auto 4 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.7.3.4
eth1IPv6LinkLocalAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link local IPv6 address for this interface. This is
present when the IPv6 mode is not OFF."
::= { eth1IPv6 4 }
--1.3.6.1.4.1.3052.18.2.4.1.1.1.7.4
eth2Mode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mode of the Ethernet2 interface: STATIC,DHCP,VLAN"
::= { ethernet2 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.1
eth2Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 IP address"
::= { ethernet2 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.2
eth2SubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 subnet mask"
::= { ethernet2 3 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.3
eth2Router OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 router"
::= { ethernet2 4 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.4
-- Ethernet2 VLAN1
eth2VLAN1ID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN1 ID"
::= { eth2VLAN1 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.1.1
eth2VLAN1Priority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN1 priority"
::= { eth2VLAN1 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.1.2
eth2VLAN1Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN1 IP address"
::= { eth2VLAN1 3 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.1.3
eth2VLAN1SubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN1 subnet mask"
::= { eth2VLAN1 4 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.1.4
eth2VLAN1Router OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN1 router"
::= { eth2VLAN1 5 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.1.5
-- Ethernet2 VLAN2
eth2VLAN2ID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN2 ID"
::= { eth2VLAN2 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.2.1
eth2VLAN2Priority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN2 priority"
::= { eth2VLAN2 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.2.2
eth2VLAN2Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN2 IP address"
::= { eth2VLAN2 3 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.2.3
eth2VLAN2SubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN2 subnet mask"
::= { eth2VLAN2 4 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.2.4
eth2VLAN2Router OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN2 router"
::= { eth2VLAN2 5 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.2.5
-- Ethernet2 VLAN3
eth2VLAN3ID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN3 ID"
::= { eth2VLAN3 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.3.1
eth2VLAN3Priority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN3 priority"
::= { eth2VLAN3 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.3.2
eth2VLAN3Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN3 IP address"
::= { eth2VLAN3 3 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.3.3
eth2VLAN3SubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN3 subnet mask"
::= { eth2VLAN3 4 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.3.4
eth2VLAN3Router OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN3 router"
::= { eth2VLAN3 5 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.3.5
-- Ethernet2 VLAN4
eth2VLAN4ID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN4 ID"
::= { eth2VLAN4 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.4.1
eth2VLAN4Priority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN4 priority"
::= { eth2VLAN4 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.4.2
eth2VLAN4Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN4 IP address"
::= { eth2VLAN4 3 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.4.3
eth2VLAN4SubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN4 subnet mask"
::= { eth2VLAN4 4 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.4.4
eth2VLAN4Router OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN4 router"
::= { eth2VLAN4 5 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.4.5
-- Ethernet2 VLAN5
eth2VLAN5ID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN5 ID"
::= { eth2VLAN5 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.5.1
eth2VLAN5Priority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN5 priority"
::= { eth2VLAN5 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.5.2
eth2VLAN5Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN5 IP address"
::= { eth2VLAN5 3 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.5.3
eth2VLAN5SubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN5 subnet mask"
::= { eth2VLAN5 4 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.5.4
eth2VLAN5Router OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN5 router"
::= { eth2VLAN5 5 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.5.5
-- Ethernet2 VLAN6
eth2VLAN6ID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN6 ID"
::= { eth2VLAN6 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.6.1
eth2VLAN6Priority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN6 priority"
::= { eth2VLAN6 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.6.2
eth2VLAN6Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN6 IP address"
::= { eth2VLAN6 3 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.6.3
eth2VLAN6SubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN6 subnet mask"
::= { eth2VLAN6 4 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.6.4
eth2VLAN6Router OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet2 VLAN6 router"
::= { eth2VLAN6 5 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.5.6.5
eth2MAC OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ethernet2 MAC"
::= { ethernet2 6 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.6
eth2IPv6Mode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls IPv6 operation for this Ethernet interface."
::= { eth2IPv6 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.7.1
eth2IPv6StaticAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"he static IPv6 address to use for this interface when in
operating in STATIC mode."
::= { eth2IPv6Static 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.7.2.1
eth2IPv6StaticRouter OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv6 router to engage as the default router when this
interface operates in STATIC mode."
::= { eth2IPv6Static 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.7.2.1
eth2IPv6AutoAddress1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"One of the automatically-acquired IPv6 addresses."
::= { eth2IPv6Auto 1 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.7.3.1
eth2IPv6AutoAddress2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"One of the automatically-acquired IPv6 addresses."
::= { eth2IPv6Auto 2 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.7.3.2
eth2IPv6AutoAddress3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"One of the automatically-acquired IPv6 addresses."
::= { eth2IPv6Auto 3 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.7.3.3
eth2IPv6AutoAddress4 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"One of the automatically-acquired IPv6 addresses."
::= { eth2IPv6Auto 4 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.7.3.4
eth2IPv6LinkLocalAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link local IPv6 address for this interface. This is
present when the IPv6 mode is not OFF."
::= { eth2IPv6 4 }
--1.3.6.1.4.1.3052.18.2.4.1.1.2.7.4
defaultRouter OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The default router/gateway"
::= { network 2 }
--1.3.6.1.4.1.3052.18.2.4.2
-- DNS
dnsTable OBJECT-TYPE
SYNTAX SEQUENCE OF DNSConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DNS server address table"
::= { network 3 }
--1.3.6.1.4.1.3052.18.2.4.3
dnsEntry OBJECT-TYPE
SYNTAX DNSConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DNS server address entry"
INDEX { dnsIndex }
::= { dnsTable 1 }
--1.3.6.1.4.1.3052.18.2.4.3.1
dnsIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for DNS server address"
::= { dnsEntry 1 }
--1.3.6.1.4.1.3052.18.2.4.3.1.1
dnsAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DNS server address"
::= { dnsEntry 2 }
--1.3.6.1.4.1.3052.18.2.4.3.1.2
hostname OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The hostname of the unit"
::= { network 4 }
--1.3.6.1.4.1.3052.18.2.4.4
hostTable OBJECT-TYPE
SYNTAX SEQUENCE OF HostConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Static host table"
::= { network 5 }
--1.3.6.1.4.1.3052.18.2.4.5
hostEntry OBJECT-TYPE
SYNTAX HostConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Static host entry"
INDEX { hostIndex }
::= { hostTable 1 }
--1.3.6.1.4.1.3052.18.2.4.5.1
hostIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for static host"
::= { hostEntry 1 }
--1.3.6.1.4.1.3052.18.2.4.5.1.1
hostDeclaration OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Static host declaration string (i.e. 'address hostname')"
::= { hostEntry 2 }
--1.3.6.1.4.1.3052.18.2.4.5.1.2
-- Network Command Processor
ncpDuplex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For network command processor: 1=Input characters are echoed; 0=no echo."
::= { network 6 }
--1.3.6.1.4.1.3052.18.2.4.6
ncpTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Network command processor inactivity timeout"
::= { network 7 }
--1.3.6.1.4.1.3052.18.2.4.7
-- SNMP
snmpAgentEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF for snmp agent"
::= { snmp 1 }
--1.3.6.1.4.1.3052.18.2.4.8.1
snmpNtfnAttempts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum of times the unit attempts to send a notification
(trap/inform) in 1 cycle"
::= { snmpNotificationTx 1 }
--1.3.6.1.4.1.3052.18.2.4.8.7.1
snmpNtfnTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of seconds between retries of sending a notification"
::= { snmpNotificationTx 2 }
--1.3.6.1.4.1.3052.18.2.4.8.7.2
snmpNtfnCycles OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of times the unit attempts a group of attempts to send
a notification (a cycle)"
::= { snmpNotificationTx 3 }
--1.3.6.1.4.1.3052.18.2.4.8.7.3
snmpNtfnSnooze OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes between cycles"
::= { snmpNotificationTx 4 }
--1.3.6.1.4.1.3052.18.2.4.8.7.4
-- SNMP proxy
snmpProxyTable OBJECT-TYPE
SYNTAX SEQUENCE OF SNMPProxyTable
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of SNMP proxy entries"
::= { snmpProxy 1 }
--1.3.6.1.4.1.3052.18.2.4.8.8.1
snmpProxyEntry OBJECT-TYPE
SYNTAX SNMPProxyTable
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for SNMP proxy table"
INDEX { snmpProxyIndex }
::= { snmpProxyTable 1 }
--1.3.6.1.4.1.3052.18.2.4.8.8.1.1
snmpProxyIndex OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for SNMP proxy table"
::= { snmpProxyEntry 1 }
--1.3.6.1.4.1.3052.18.2.4.8.8.1.1.1
snmpProxyEgressOIDBranch OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The OID branch to trigger the proxy function. This should cover
the device to proxy. If blank then this proxy entry is disabled."
::= { snmpProxyEntry 2 }
--1.3.6.1.4.1.3052.18.2.4.8.8.1.1.2
snmpProxyIP OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the device to proxy."
::= { snmpProxyEntry 3 }
--1.3.6.1.4.1.3052.18.2.4.8.8.1.1.3
snmpProxyPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP port on which the device to proxy listens."
::= { snmpProxyEntry 4 }
--1.3.6.1.4.1.3052.18.2.4.8.8.1.1.4
snmpProxyIngressOIDBranch OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The OID branch to be remapped to egress OID branch to trigger the
proxy function. If blank then the egress OID branch is proxied
without remapping."
::= { snmpProxyEntry 5 }
--1.3.6.1.4.1.3052.18.2.4.8.8.1.1.5
snmpProxyName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of this proxy entry."
::= { snmpProxyEntry 6 }
--1.3.6.1.4.1.3052.18.2.4.8.8.1.1.6
-- SNMP Poll
snmpPMode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mode of poll operation: OFF or POLL ONLY (just make the results
available to view)."
::= { snmpPoll 1 }
--1.3.6.1.4.1.3052.18.2.4.8.9.1
snmpPRequestTable OBJECT-TYPE
SYNTAX SEQUENCE OF SNMPPollRequestConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of SNMP Poll requests."
::= { snmpPoll 4 }
--1.3.6.1.4.1.3052.18.2.4.8.9.4
snmpPRequestEntry OBJECT-TYPE
SYNTAX SNMPPollRequestConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table pf SNMP Poll requests."
INDEX { snmpPRequestIndex }
::= { snmpPRequestTable 1 }
--1.3.6.1.4.1.3052.18.2.4.8.9.4.1
snmpPRequestIndex OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of SNMP Poll requests."
::= { snmpPRequestEntry 1 }
--1.3.6.1.4.1.3052.18.2.4.8.9.4.1.1
snmpPRequestDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A description for this single telemetry request; no functional effect."
::= { snmpPRequestEntry 2 }
--1.3.6.1.4.1.3052.18.2.4.8.9.4.1.2
snmpPRequestAgent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SNMP Agent IP address or hostname for this single telemetry request."
::= { snmpPRequestEntry 3 }
--1.3.6.1.4.1.3052.18.2.4.8.9.4.1.3
snmpPRequestReadcom OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SNMP read community for this single telemetry request."
::= { snmpPRequestEntry 4 }
--1.3.6.1.4.1.3052.18.2.4.8.9.4.1.4
snmpPRequestOID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SNMP object identifier for this single telemetry request."
::= { snmpPRequestEntry 5 }
--1.3.6.1.4.1.3052.18.2.4.8.9.4.1.5
snmpPRequestPeriod OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"How many seconds between periodic SNMP polls of this
single telemetry request."
::= { snmpPRequestEntry 6 }
--1.3.6.1.4.1.3052.18.2.4.8.9.4.1.6
snmpPRequestResultStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the last attempt for this telemetry request."
::= { snmpPRequestEntry 10 }
--1.3.6.1.4.1.3052.18.2.4.8.9.4.1.10
snmpPRequestResultValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The telemetry value if the last request was successful."
::= { snmpPRequestEntry 11 }
--1.3.6.1.4.1.3052.18.2.4.8.9.4.1.11
snmpPRequestResultTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The timestamp of the last telemetry request."
::= { snmpPRequestEntry 12 }
--1.3.6.1.4.1.3052.18.2.4.8.9.4.1.12
snmpPRequestResultType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the telemetry as reported by the agent."
::= { snmpPRequestEntry 13 }
--1.3.6.1.4.1.3052.18.2.4.8.9.4.1.13
-- FTP
ftpPushEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable FTP push for REGULAR (protocol: FTP) or SECURE (protocol:
SFTP) operation, or disable it (OFF)"
::= { ftpPush 1 }
--1.3.6.1.4.1.3052.18.2.4.9.1
ftpPushServer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"FTP server to which data should be pushed"
::= { ftpPush 2 }
--1.3.6.1.4.1.3052.18.2.4.9.2
ftpPushAccount OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"FTP push account"
::= { ftpPush 5 }
--1.3.6.1.4.1.3052.18.2.4.9.5
ftpPushDirectory OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"FTP push directory"
::= { ftpPush 6 }
--1.3.6.1.4.1.3052.18.2.4.9.6
ftpPushperiod OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes between pushes"
::= { ftpPush 7 }
--1.3.6.1.4.1.3052.18.2.4.9.7
ftpPushPushFileTable OBJECT-TYPE
SYNTAX SEQUENCE OF FTPPushPushFileConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of files to push"
::= { ftpPush 8 }
--1.3.6.1.4.1.3052.18.2.4.9.8
ftpPushPushFileEntry OBJECT-TYPE
SYNTAX FTPPushPushFileConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of files to push"
INDEX { ftpPushPushFileIndex }
::= { ftpPushPushFileTable 1 }
--1.3.6.1.4.1.3052.18.2.4.9.8.1
ftpPushPushFileIndex OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of files to push"
::= { ftpPushPushFileEntry 1 }
--1.3.6.1.4.1.3052.18.2.4.9.8.1.1
ftpPushPushFile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF push this local FILEx"
::= { ftpPushPushFileEntry 2 }
--1.3.6.1.4.1.3052.18.2.4.9.8.1.2
ftpPushPushAudit OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF push the audit log"
::= { ftpPush 9 }
--1.3.6.1.4.1.3052.18.2.4.9.9
ftpPushPushAlarms OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF push the alarms/events file"
::= { ftpPush 10 }
--1.3.6.1.4.1.3052.18.2.4.9.10
ftpPushRemoteFileTable OBJECT-TYPE
SYNTAX SEQUENCE OF FTPPushRemoteFileConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of remote names of files to push"
::= { ftpPush 11 }
--1.3.6.1.4.1.3052.18.2.4.9.11
ftpPushRemoteFileEntry OBJECT-TYPE
SYNTAX FTPPushRemoteFileConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of remote names of files to push"
INDEX { ftpPushRemoteFileIndex }
::= { ftpPushRemoteFileTable 1 }
--1.3.6.1.4.1.3052.18.2.4.9.11.1
ftpPushRemoteFileIndex OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of remote names of files to push"
::= { ftpPushRemoteFileEntry 1 }
--1.3.6.1.4.1.3052.18.2.4.9.11.1
ftpPushRemoteFileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"remote name of pushed FILEx (name on server)"
::= { ftpPushRemoteFileEntry 2 }
--1.3.6.1.4.1.3052.18.2.4.9.11.2
ftpPushRemoteAlarmName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Filename on server for alarms"
::= { ftpPush 12 }
--1.3.6.1.4.1.3052.18.2.4.9.12
ftpPushPassive OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF use ftp passive mode"
::= { ftpPush 13 }
--1.3.6.1.4.1.3052.18.2.4.9.13
ftpPushIncludeDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF include the date in the name of the pushed file"
::= { ftpPush 14 }
--1.3.6.1.4.1.3052.18.2.4.9.14
ftpPushIncludeTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF include the time in the name of the pushed file"
::= { ftpPush 15 }
--1.3.6.1.4.1.3052.18.2.4.9.15
ftpPushIncludeSeq OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF include a sequence number in the name of the pushed file"
::= { ftpPush 16 }
--1.3.6.1.4.1.3052.18.2.4.9.16
ftpPushPermissions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Unix permissions to apply to pushed files (octal notation)."
::= { ftpPush 17 }
--1.3.6.1.4.1.3052.18.2.4.9.17
-- Routing
ethRoutingEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF unit routes IP traffic from Ethernet to PPP/Wireless"
::= { routing 2 }
--1.3.6.1.4.1.3052.18.2.4.11.2
ethRoutingNATEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF unit applies NAT on routed IP frames egressing the
unit on its PPP interface"
::= { routing 3 }
--1.3.6.1.4.1.3052.18.2.4.11.3
-- IP Restrictions
ipRestrictionTable OBJECT-TYPE
SYNTAX SEQUENCE OF IPRestrictionConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of IP restrictions"
::= { ipRestriction 1 }
--1.3.6.1.4.1.3052.18.2.4.12.1.1
ipRestrictionEntry OBJECT-TYPE
SYNTAX IPRestrictionConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of IP restrictions"
INDEX { ipRestrictionIndex }
::= { ipRestrictionTable 1 }
--1.3.6.1.4.1.3052.18.2.4.12.1.1
ipRestrictionIndex OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of IP restrictions"
::= { ipRestrictionEntry 1 }
--1.3.6.1.4.1.3052.18.2.4.12.1.1.1.1
ipRestrictionEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable this IP restriction"
::= { ipRestrictionEntry 2 }
--1.3.6.1.4.1.3052.18.2.4.12.1.1.1.2
ipRestrictionMask OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP restriction mask"
::= { ipRestrictionEntry 3 }
--1.3.6.1.4.1.3052.18.2.4.12.1.1.1.3
-- Traps
trapIncludeDateTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF include date and time in stock trap message"
::= { trapInclude 1 }
--1.3.6.1.4.1.3052.18.2.4.14.1.1
trapIncludeSiteName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF include site name in stock trap message"
::= { trapInclude 2 }
--1.3.6.1.4.1.3052.18.2.4.14.1.2
trapIncludeSensorID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF include sensor ID in stock trap message"
::= { trapInclude 3 }
--1.3.6.1.4.1.3052.18.2.4.14.1.3
trapIncludeUDName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF include user defined name in stock trap message"
::= { trapInclude 4 }
--1.3.6.1.4.1.3052.18.2.4.14.1.4
trapIncludeUDState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF include user defined state in stock trap message"
::= { trapInclude 5 }
--1.3.6.1.4.1.3052.18.2.4.14.1.5
trapIncludeSourceAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF include source IP address in stock trap message"
::= { trapInclude 6 }
--1.3.6.1.4.1.3052.18.2.4.14.1.6
trapAuthFailEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable trap sent upon SNMP authentication failure"
::= { trap 2 }
--1.3.6.1.4.1.3052.18.2.4.14.2
-- Wireless
wirelessMode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Wireless mode (OFF,PERMANENT-EDGE)"
::= { wireless 1 }
--1.3.6.1.4.1.3052.18.2.4.16.1
wirelessAPN OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Wireless access point name"
::= { wireless 2 }
--1.3.6.1.4.1.3052.18.2.4.16.2
wirelessIdleTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Wireless idle timeout"
::= { wireless 3 }
--1.3.6.1.4.1.3052.18.2.4.16.3
wirelessPIN OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Wireless modem SIM PIN"
::= { wireless 5 }
--1.3.6.1.4.1.3052.18.2.4.16.5
wirelessDRE OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default route enable for wireless network interface.
When this is ON, the wireless link, if up, becomes
the default route, overriding the default route setting
(defaultRouter object). When OFF, the default route
setting controls the default route and the wireless link
does not become the default route."
::= { wireless 9 }
--1.3.6.1.4.1.3052.18.2.4.16.9
wirelessPPPUsername OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Username for PPP-based wireless modem connections."
::= { wireless 10 }
--1.3.6.1.4.1.3052.18.2.4.16.10
wirelessFirewall OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable wireless modem firewall."
::= { wireless 11 }
--1.3.6.1.4.1.3052.18.2.4.16.11
wirelessKeepaliveThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes of no RX activity before sending keep-alive."
::= { wireless 12 }
--1.3.6.1.4.1.3052.18.2.4.16.12
wirelessPPPDebug OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable wireless modem PPP debug."
::= { wireless 13 }
--1.3.6.1.4.1.3052.18.2.4.16.13
wirelessConnEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable wireless modem connectivity check."
::= { wirelessConnectivity 1 }
--1.3.6.1.4.1.3052.18.2.4.16.20.1
wirelessConnCheckInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Wireless connectivity check interval in minutes."
::= { wirelessConnectivity 2 }
--1.3.6.1.4.1.3052.18.2.4.16.20.2
wirelessConnFailThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Wireless connectivity fail threshold."
::= { wirelessConnectivity 3 }
--1.3.6.1.4.1.3052.18.2.4.16.20.3
wirelessConnIP1 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Wireless connectivity check IP address 1."
::= { wirelessConnectivity 10 }
--1.3.6.1.4.1.3052.18.2.4.16.20.10
wirelessConnIP2 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Wireless connectivity check IP address 2."
::= { wirelessConnectivity 11 }
--1.3.6.1.4.1.3052.18.2.4.16.20.11
-- Email
emailServer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SMTP server to which the unit sends email"
::= { email 1 }
--1.3.6.1.4.1.3052.18.2.4.17.1
emailDomain OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Domain to use in recipient address"
::= { email 2 }
--1.3.6.1.4.1.3052.18.2.4.17.2
emailAuthEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable SMTP authentication"
::= { email 3 }
--1.3.6.1.4.1.3052.18.2.4.17.3
-- Advanced network config
arpFilter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ARP filter code"
::= { netAdvanced 1 }
--1.3.6.1.4.1.3052.18.2.4.18.1
-- Web interface
webEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF for the web interface"
::= { web 1 }
--1.3.6.1.4.1.3052.18.2.4.19.1
webPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TCP port on which web interface listens"
::= { web 2 }
--1.3.6.1.4.1.3052.18.2.4.19.2
webTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Web interface session timeout (seconds)"
::= { web 3 }
--1.3.6.1.4.1.3052.18.2.4.19.3
-- IPv6
ipv6DefaultRouter OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv6 default router in use."
::= { ipv6 1 }
--1.3.6.1.4.1.3052.18.2.4.21.1
-- CPE table
cpeTable OBJECT-TYPE
SYNTAX SEQUENCE OF CPEConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of CPEs"
::= { cpe 1 }
--1.3.6.1.4.1.3052.18.2.4.22.1
cpeEntry OBJECT-TYPE
SYNTAX CPEConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of CPEs"
INDEX { cpeIndex }
::= { cpeTable 1 }
--1.3.6.1.4.1.3052.18.2.4.22.1.1
cpeIndex OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of CPEs"
::= { cpeEntry 1 }
--1.3.6.1.4.1.3052.18.2.4.22.1.1.1
cpeHost OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CPE host (IP address or DNS name)"
::= { cpeEntry 2 }
--1.3.6.1.4.1.3052.18.2.4.22.1.1.2
cpeName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CPE name, informational only"
::= { cpeEntry 3 }
--1.3.6.1.4.1.3052.18.2.4.22.1.1.3
cpeDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CPE description, informational only"
::= { cpeEntry 4 }
--1.3.6.1.4.1.3052.18.2.4.22.1.1.4
cpeKeepalive OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of seconds between each successful ping request."
::= { cpeEntry 5 }
--1.3.6.1.4.1.3052.18.2.4.22.1.1.5
cpeThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of unsuccessful pings that triggers the CPE event."
::= { cpeEntry 6 }
--1.3.6.1.4.1.3052.18.2.4.22.1.1.6
cpeEventReminderInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CPE event reminder interval (minutes)."
::= { cpeEntry 7 }
--1.3.6.1.4.1.3052.18.2.4.22.1.1.7
cpeKeepaliveTicks OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CPE ping period in 16ths of a second (nonzero overrides keepalive)."
::= { cpeEntry 20 }
--1.3.6.1.4.1.3052.18.2.4.22.1.1.20
cpePingSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of bytes in CPE ping payload"
::= { cpeEntry 21 }
--1.3.6.1.4.1.3052.18.2.4.22.1.11
cpeInfoReset OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set any number to reset CPE ping stats."
::= { cpeEntry 30 }
--1.3.6.1.4.1.3052.18.2.4.22.1.1.30
cpeInfoNumReq OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of requests transmitted."
::= { cpeEntry 31 }
--1.3.6.1.4.1.3052.18.2.4.22.1.1.31
cpeInfoNumGoodResp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of non-corrupt responses."
::= { cpeEntry 32 }
--1.3.6.1.4.1.3052.18.2.4.22.1.1.32
cpeInfoNumBadResp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of corrupt responses."
::= { cpeEntry 33 }
--1.3.6.1.4.1.3052.18.2.4.22.1.1.33
cpeInfoNumLostResp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of requests with no response."
::= { cpeEntry 34 }
--1.3.6.1.4.1.3052.18.2.4.22.1.1.34
cpeInfoPercentLoss OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percent loss (missing responses / total requests)."
::= { cpeEntry 35 }
--1.3.6.1.4.1.3052.18.2.4.22.1.1.35
cpeInfoPercentBad OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percent corrupt (corrupt responses / total requests)."
::= { cpeEntry 36 }
--1.3.6.1.4.1.3052.18.2.4.22.1.1.36
--***************************************************************************************
--Time Section 2.8
--***************************************************************************************
clock OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Text string for date and time;
e.g. 'SUN 01/02/98 12:34:27'. When setting
this object, only the date and time are
required; the unit will ignore a specified
day of week because it is calculated from
the date and time. When this object is included
in a notification as a varbind, it represents
the time that the triggering event occurred."
::= { time 1 }
--1.3.6.1.4.1.3052.18.2.8.1
--***************************************************************************************
--Console Section 2.10
--***************************************************************************************
consoleDuplex OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF characters echoed on telnet command session"
::= { console 1 }
--1.3.6.1.4.1.3052.18.2.10.1
consoleTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes of inactivity after which telnet command session is terminated"
::= { console 2 }
--1.3.6.1.4.1.3052.18.2.10.2
consoleConfirm OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF Prompt to confirm certain actions"
::= { console 7 }
--1.3.6.1.4.1.3052.18.2.10.7
--***************************************************************************************
--Core Security Section 2.11.1
--***************************************************************************************
scShowPasswordPrompt OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF show password prompt upon login"
::= { secCore 1 }
--1.3.6.1.4.1.3052.18.2.11.1.1
scConsoleLoginRequired OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF login required upon connecting via console"
::= { secCore 2 }
--1.3.6.1.4.1.3052.18.2.11.1.2
scAuthMode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Authentication mode (USERNAME/PW,PW/USERNAME,PASSWORD ONLY)"
::= { secCore 7 }
--1.3.6.1.4.1.3052.18.2.11.1.7
scRightsGroup OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The set of aliases used for the 8 available rights levels"
::= { secCore 8 }
--1.3.6.1.4.1.3052.18.2.11.1.8
scSecret OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shared secret for challenges"
::= { secCore 9 }
--1.3.6.1.4.1.3052.18.2.11.1.9
--***************************************************************************************
--User Security Section 2.11.2
--***************************************************************************************
secUserTable OBJECT-TYPE
SYNTAX SEQUENCE OF SecUserConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of users"
::= { unitSecurity 2 }
--1.3.6.1.4.1.3052.18.2.11.2
secUserEntry OBJECT-TYPE
SYNTAX SecUserConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of users"
INDEX { secUserIndex }
::= { secUserTable 1 }
--1.3.6.1.4.1.3052.18.2.11.2.1
secUserIndex OBJECT-TYPE
SYNTAX Integer32 (1..12)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of users"
::= { secUserEntry 1 }
--1.3.6.1.4.1.3052.18.2.11.2.1.1
secUserEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable user"
::= { secUserEntry 2 }
--1.3.6.1.4.1.3052.18.2.11.2.1.2
secUserConnectVia OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Methods by which user is allowed to connect:
L=local (console)
T=Telnet
F=FTP
Ss=SSH
W=Web
"
::= { secUserEntry 5 }
--1.3.6.1.4.1.3052.18.2.11.2.1.5
secUserLoginTo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The function presented to the user upon login (COMMAND,
PASSTHROUGH,MENU)"
::= { secUserEntry 6 }
--1.3.6.1.4.1.3052.18.2.11.2.1.6
secUserAccessFile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The default access file associated with the user"
::= { secUserEntry 7 }
--1.3.6.1.4.1.3052.18.2.11.2.1.7
secUserPTEscapeTo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The function presented to the user upon escaping pass-
through: currently only MENU"
::= { secUserEntry 9 }
--1.3.6.1.4.1.3052.18.2.11.2.1.9
secUserRights OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The rights level granted to this user"
::= { secUserEntry 11 }
--1.3.6.1.4.1.3052.18.2.11.2.1.11
secUserEventsReadAccess OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DENY/ALLOW user to read the events/alarms file"
::= { secUserEntry 13 }
--1.3.6.1.4.1.3052.18.2.11.2.1.13
secUserAuditReadAccess OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DENY/ALLOW user to read the audit log"
::= { secUserEntry 14 }
--1.3.6.1.4.1.3052.18.2.11.2.1.14
secUserEventsWriteAccess OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DENY/ALLOW user to delete the events file"
::= { secUserEntry 16 }
--1.3.6.1.4.1.3052.18.2.11.2.1.16
secUserAuditWriteAccess OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DENY/ALLOW user to write to the audit log"
::= { secUserEntry 17 }
--1.3.6.1.4.1.3052.18.2.11.2.1.17
secUserExpiration OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Expiration date/time of this user"
::= { secUserEntry 18 }
--1.3.6.1.4.1.3052.18.2.11.2.1.18
secUserChallengeConsoleMode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Console challenge mode: when user logs in via console, unit
allows access (OFF), or presents a challenge (CHALLENGE)"
::= { secUserEntry 24 }
--1.3.6.1.4.1.3052.18.2.11.2.1.24
secUserChallengeExpiration OBJECT-TYPE
SYNTAX Integer32 (0..180)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time (in minutes) after which a one-time-password is sent
that it can be used to log in"
::= { secUserEntry 27 }
--1.3.6.1.4.1.3052.18.2.11.2.1.27
--***************************************************************************************
--Factory Security Section 2.11.3
--***************************************************************************************
sfEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable factory access"
::= { secFactory 1 }
--1.3.6.1.4.1.3052.18.2.11.3.1
sfSecret OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Secret used for factory access"
::= { secFactory 2 }
--1.3.6.1.4.1.3052.18.2.11.3.2
--***************************************************************************************
--Event Section 2.12
--***************************************************************************************
--***************************************************************************************
--Event Core Section 2.12.1
--***************************************************************************************
evClassNameTable OBJECT-TYPE
SYNTAX SEQUENCE OF EventClassConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of classes"
::= { evCore 1 }
--1.3.6.1.4.1.3052.18.2.12.1.1
evClassNameEntry OBJECT-TYPE
SYNTAX EventClassConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of classes"
INDEX { evClassNameIndex }
::= { evClassNameTable 1 }
--1.3.6.1.4.1.3052.18.2.12.1.1.1
evClassNameIndex OBJECT-TYPE
SYNTAX Integer32 (1..12)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of classes"
::= { evClassNameEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.1.1.1.1
evClassName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class name for this slot"
::= { evClassNameEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.1.1.1.2
evReminderInterval OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Interval (minutes) between EventSensor reminder events"
::= { evCore 2 }
--1.3.6.1.4.1.3052.18.2.12.1.2
evLogEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable event log"
::= { evLog 1 }
--1.3.6.1.4.1.3052.18.2.12.1.3.1
evLogStoreAlarm OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF store data alarms in event log"
::= { evLog 2 }
--1.3.6.1.4.1.3052.18.2.12.1.3.2
evLogMaxSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"max size (in KB) of event log"
::= { evLog 3 }
--1.3.6.1.4.1.3052.18.2.12.1.3.3
evLogStoreSensor OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF store EventSensor events in event log"
::= { evLog 4 }
--1.3.6.1.4.1.3052.18.2.12.1.3.4
evLogTimeStampAlarms OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF put timestamps on event log entries"
::= { evLog 5 }
--1.3.6.1.4.1.3052.18.2.12.1.3.5
evLogPrependName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF prepend data event name to data alarm records in event
log"
::= { evLog 6 }
--1.3.6.1.4.1.3052.18.2.12.1.3.6
evMgmtReprocess OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of sensors that have generated events since reset.
Write this to reprocess each sensor's last generated event
since reset. The value to write determines what kind of
events should be reprocessed:
'all': all sensor events
'cc': cc events
'temperature': temperature events
'humidity': humidity events
'analog': analog input events
'fuel': fuel sensor events
'acpm': AC power monitor events
'battery': battery monitor events"
::= { evMgmt 3 }
--1.3.6.1.4.1.3052.18.2.12.1.4.3
--***************************************************************************************
--Scheduled Event 1 Section 2.12.5
--***************************************************************************************
evSched1Enable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable this scheduled event"
::= { evSched1 1 }
--1.3.6.1.4.1.3052.18.2.12.5.1
evSched1Actions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for this scheduled event"
::= { evSched1 2 }
--1.3.6.1.4.1.3052.18.2.12.5.2
evSched1Message OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Message for this scheduled event"
::= { evSched1 3 }
--1.3.6.1.4.1.3052.18.2.12.5.3
evSched1TrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for this scheduled event"
::= { evSched1 4 }
--1.3.6.1.4.1.3052.18.2.12.5.4
evSched1Class OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for this scheduled event"
::= { evSched1 5 }
--1.3.6.1.4.1.3052.18.2.12.5.5
evSched1Sunday OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time on Sunday (HH:MM) when this scheduled event triggers"
::= { evSched1 6 }
--1.3.6.1.4.1.3052.18.2.12.5.6
evSched1Monday OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time on Monday (HH:MM) when this scheduled event triggers"
::= { evSched1 7 }
--1.3.6.1.4.1.3052.18.2.12.5.7
evSched1Tuesday OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time on Tuesday (HH:MM) when this scheduled event triggers"
::= { evSched1 8 }
--1.3.6.1.4.1.3052.18.2.12.5.8
evSched1Wednesday OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time on Wednesday (HH:MM) when this scheduled event triggers"
::= { evSched1 9 }
--1.3.6.1.4.1.3052.18.2.12.5.9
evSched1Thursday OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time on Thursday (HH:MM) when this scheduled event triggers"
::= { evSched1 10 }
--1.3.6.1.4.1.3052.18.2.12.5.10
evSched1Friday OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time on Friday (HH:MM) when this scheduled event triggers"
::= { evSched1 11 }
--1.3.6.1.4.1.3052.18.2.12.5.11
evSched1Saturday OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time on Saturday (HH:MM) when this scheduled event triggers"
::= { evSched1 12 }
--1.3.6.1.4.1.3052.18.2.12.5.12
evSched1Exclusions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Exclusions (space-separated MM/DD-formatted dates) for this
scheduled event"
::= { evSched1 13 }
--1.3.6.1.4.1.3052.18.2.12.5.13
--***************************************************************************************
--Scheduled Event 2 Section 2.12.6
--***************************************************************************************
evSched2Enable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable this scheduled event"
::= { evSched2 1 }
--1.3.6.1.4.1.3052.18.2.12.6.1
evSched2Actions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for this scheduled event"
::= { evSched2 2 }
--1.3.6.1.4.1.3052.18.2.12.6.2
evSched2Message OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Message for this scheduled event"
::= { evSched2 3 }
--1.3.6.1.4.1.3052.18.2.12.6.3
evSched2TrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for this scheduled event"
::= { evSched2 4 }
--1.3.6.1.4.1.3052.18.2.12.6.4
evSched2Class OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for this scheduled event"
::= { evSched2 5 }
--1.3.6.1.4.1.3052.18.2.12.6.5
evSched2Sunday OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time on Sunday (HH:MM) when this scheduled event triggers"
::= { evSched2 6 }
--1.3.6.1.4.1.3052.18.2.12.6.6
evSched2Monday OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time on Monday (HH:MM) when this scheduled event triggers"
::= { evSched2 7 }
--1.3.6.1.4.1.3052.18.2.12.6.7
evSched2Tuesday OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time on Tuesday (HH:MM) when this scheduled event triggers"
::= { evSched2 8 }
--1.3.6.1.4.1.3052.18.2.12.6.8
evSched2Wednesday OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time on Wednesday (HH:MM) when this scheduled event triggers"
::= { evSched2 9 }
--1.3.6.1.4.1.3052.18.2.12.6.9
evSched2Thursday OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time on Thursday (HH:MM) when this scheduled event triggers"
::= { evSched2 10 }
--1.3.6.1.4.1.3052.18.2.12.6.10
evSched2Friday OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time on Friday (HH:MM) when this scheduled event triggers"
::= { evSched2 11 }
--1.3.6.1.4.1.3052.18.2.12.6.11
evSched2Saturday OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time on Saturday (HH:MM) when this scheduled event triggers"
::= { evSched2 12 }
--1.3.6.1.4.1.3052.18.2.12.6.12
evSched2Exclusions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Exclusions (space-separated MM/DD-formatted dates) for this
scheduled event"
::= { evSched2 13 }
--1.3.6.1.4.1.3052.18.2.12.6.13
--***************************************************************************************
--Serial Handshaking Low Section 2.12.7
--***************************************************************************************
evShskLowTable OBJECT-TYPE
SYNTAX SEQUENCE OF SerialHandshakingLowEventConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of serial handshaking low events"
::= { event 7 }
--1.3.6.1.4.1.3052.18.2.12.7
evShskLowEntry OBJECT-TYPE
SYNTAX SerialHandshakingLowEventConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of serial handshaking low events"
INDEX { evShskLowIndex }
::= { evShskLowTable 1 }
--1.3.6.1.4.1.3052.18.2.12.7.1
evShskLowIndex OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of serial handshaking low events"
::= { evShskLowEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.7.1.1
evShskLowEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF: enable the serial handshaking low event for this port"
::= { evShskLowEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.7.1.2
evShskLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for the serial handshaking low event for this port"
::= { evShskLowEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.7.1.3
evShskLowMessage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Message for the serial handshaking low event for this port"
::= { evShskLowEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.7.1.4
evShskLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for the serial handshaking low event for this port"
::= { evShskLowEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.7.1.5
evShskLowTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for the serial handshaking low event for this port"
::= { evShskLowEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.7.1.6
--***************************************************************************************
--Serial Handshaking High Section 2.12.8
--***************************************************************************************
evShskHighTable OBJECT-TYPE
SYNTAX SEQUENCE OF SerialHandshakingHighEventConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of serial handshaking high events"
::= { event 8 }
--1.3.6.1.4.1.3052.18.2.12.8
evShskHighEntry OBJECT-TYPE
SYNTAX SerialHandshakingHighEventConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of serial handshaking high events"
INDEX { evShskHighIndex }
::= { evShskHighTable 1 }
--1.3.6.1.4.1.3052.18.2.12.8.1
evShskHighIndex OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of serial handshaking high events"
::= { evShskHighEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.8.1.1
evShskHighEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF: enable the serial handshaking high event for this
port"
::= { evShskHighEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.8.1.2
evShskHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for the serial handshaking high event for this port"
::= { evShskHighEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.8.1.3
evShskHighMessage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Message for the serial handshaking high event for this port"
::= { evShskHighEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.8.1.4
evShskHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for the serial handshaking high event for this port"
::= { evShskHighEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.8.1.5
evShskHighTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for the serial handshaking high event for this
port"
::= { evShskHighEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.8.1.6
--***************************************************************************************
--No Sensor Event Section 2.12.9
--***************************************************************************************
evNoSensorTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Timeout (seconds) after which an EventSensor becomes
unresponsive that this event is triggered"
::= { evNoSensor 1 }
--1.3.6.1.4.1.3052.18.2.12.9.1
evNoSensorActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for no sensor event"
::= { evNoSensor 2 }
--1.3.6.1.4.1.3052.18.2.12.9.2
evNoSensorTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for no sensor event"
::= { evNoSensor 3 }
--1.3.6.1.4.1.3052.18.2.12.9.3
evNoSensorClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for no sensor event"
::= { evNoSensor 4 }
--1.3.6.1.4.1.3052.18.2.12.9.4
--***************************************************************************************
--Fuel Sensor Config Section 2.12.11
--***************************************************************************************
fuelSensorGeneralTable OBJECT-TYPE
SYNTAX SEQUENCE OF FuelSensorConfigGeneral
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes general fuel sensor attributes."
::= { fuelSensor 1 }
--1.3.6.1.4.1.3052.18.2.12.11.1
fsGenEntry OBJECT-TYPE
SYNTAX FuelSensorConfigGeneral
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for fuel sensor general config table."
INDEX { fsGenIndex }
::= { fuelSensorGeneralTable 1 }
--1.3.6.1.4.1.3052.18.2.12.11.1.1
fsGenIndex OBJECT-TYPE
SYNTAX Integer32 (1..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which fuel sensor in the fuel sensor general config table."
::= { fsGenEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.11.1.1.1
fsGenName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor name."
::= { fsGenEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.11.1.1.2
fsGenSensorType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Type of fuel sensor in use; NONE disables the fuel sensor."
::= { fsGenEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.11.1.1.3
fsGenDistanceUnit OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Distance units in use when setting and indicating tank dimensions."
::= { fsGenEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.11.1.1.4
fsGenRawValueTop OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Analog input reading corresponding to the SENSOR FULL point."
::= { fsGenEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.11.1.1.5
fsGenTopOffset OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Distance, in the specified distance unit, between the SENSOR FULL
point and the TANK FULL point. The value is positive if the
SENSOR FULL point is above the TANK FULL point, and negative if it is
below."
::= { fsGenEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.11.1.1.6
fsGenRawValueBottom OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Analog input reading corresponding to the minimum fluid height
measurable by the fuel sensor."
::= { fsGenEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.11.1.1.7
fsGenBottomOffset OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Distance, in the specified distance unit, between the SENSOR EMPTY
point and the TANK EMPTY point. The value is positive if the
SENSOR EMPTY point is above the TANK EMPTY point, and negative if it
is below."
::= { fsGenEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.11.1.1.8
fsGenInputES OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Which eventsensor contains the analog input associated with this fuel
sensor. Allowed values are 200 (for internal ES), or 1-16."
::= { fsGenEntry 9 }
--1.3.6.1.4.1.3052.18.2.12.11.1.1.9
fsGenInputPoint OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Which analog input point, on the specified eventsensor, that is
associated with the fuel sensor."
::= { fsGenEntry 10 }
--1.3.6.1.4.1.3052.18.2.12.11.1.1.10
fsGenFilterAveraging OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor filter averaging factor."
::= { fsGenEntry 11 }
--1.3.6.1.4.1.3052.18.2.12.11.1.1.11
fsGenSysrepEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor System Reporting enable."
::= { fsGenEntry 12 }
--1.3.6.1.4.1.3052.18.2.12.11.1.1.12
fsGenSysrepThreshold OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor System Reporting threshold (floating point value)."
::= { fsGenEntry 13 }
--1.3.6.1.4.1.3052.18.2.12.11.1.1.13
fsGenSysrepLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor System Reporting limit."
::= { fsGenEntry 14 }
--1.3.6.1.4.1.3052.18.2.12.11.1.1.14
fsGenSysrepPackage OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor System Reporting package number."
::= { fsGenEntry 15 }
--1.3.6.1.4.1.3052.18.2.12.11.1.1.15
fsGenSysrepType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor ASM profile type."
::= { fsGenEntry 16 }
--1.3.6.1.4.1.3052.18.2.12.11.1.1.16
fsGenEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor enable."
::= { fsGenEntry 17 }
--1.3.6.1.4.1.3052.18.2.12.11.1.1.17
fuelSensorTankTable OBJECT-TYPE
SYNTAX SEQUENCE OF FuelSensorConfigTank
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes tank-specific fuel sensor attributes."
::= { fuelSensor 2 }
--1.3.6.1.4.1.3052.18.2.12.11.2
fsTankEntry OBJECT-TYPE
SYNTAX FuelSensorConfigTank
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for fuel sensor tank config table."
INDEX { fsTankIndex }
::= { fuelSensorTankTable 1 }
--1.3.6.1.4.1.3052.18.2.12.11.2.1
fsTankIndex OBJECT-TYPE
SYNTAX Integer32 (1..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which fuel sensor in the fuel sensor tank config table."
::= { fsTankEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.11.2.1.1
fsTankHeight OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Height of the tank, from the TANK EMPTY point to the TANK FULL point,
in the specified distance unit (i.e. TANK HEIGHT). This is a
floating point value."
::= { fsTankEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.11.2.1.2
fsTankDimA OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tank dimension measurement A for certain tank profiles. For
HORIZ OVAL, this is the length of the straight section. This is a
floating point value."
::= { fsTankEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.11.2.1.3
fsTankDimB OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tank dimension measurement B for certain tank profiles. For
HORIZ OVAL, this is the radius of the curved section. This is a
floating point value."
::= { fsTankEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.11.2.1.4
fsTankVolume OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"How many volume units the tank contains, when full. This is a
floating point value."
::= { fsTankEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.11.2.1.5
fsTankVolumeUnit OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of the unit representing fluid volume in the tank. This is only
used for display purposes; it does not affect the volume calculation."
::= { fsTankEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.11.2.1.6
fsTankShape OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The shape of the fuel tank. A value of LINEAR produces a fluid
volume reading that is directly proportional to fluid height. The
HORIZ CYL and HORIZ OVAL settings use a hard-coded formula to
calculate the volume. The CUSTOM setting uses a strapping table that
must be configured as well (see fuelSensorCustomTankTable)."
::= { fsTankEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.11.2.1.7
fuelSensorCustomTankTable OBJECT-TYPE
SYNTAX SEQUENCE OF FuelSensorConfigCustomTankStrapping
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes the custom tank strapping table. Each fuel
sensor has a table of height/volume pairs in service only when the tank
shape (fsTankShape) in CUSTOM. This allows the unit to calculate
volumes for nonstandard tank shapes, to the degree that accurate
height/volume measurements can be configured. This SNMP table has two
indexes: the first for which fuel sensor and the second for which
height/volume pair."
::= { fuelSensor 3 }
--1.3.6.1.4.1.3052.18.2.12.11.3
fsCustomTankEntry OBJECT-TYPE
SYNTAX FuelSensorConfigCustomTankStrapping
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for fuel sensor custom tank config table."
INDEX { fsCustomTankIndexFS, fsCustomTankIndexDatum }
::= { fuelSensorCustomTankTable 1 }
--1.3.6.1.4.1.3052.18.2.12.11.3.1
fsCustomTankIndexFS OBJECT-TYPE
SYNTAX Integer32 (1..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which fuel sensor in the fuel sensor tank config table. This is the
first of two indexes for this SNMP table."
::= { fsCustomTankEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.11.3.1.1
fsCustomTankIndexDatum OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which hight/volume pair: there are 32 pairs per fuel sensor. This is
the second of two indexes for this SNMP table."
::= { fsCustomTankEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.11.3.1.2
fsCustomTankHeight OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Height of custom tank height/volume pair. This is a floating point
value."
::= { fsCustomTankEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.11.3.1.3
fsCustomTankVolume OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Volume of custom tank height/volume pair. This is a floating point
value."
::= { fsCustomTankEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.11.3.1.4
fuelSensorVolumeTable OBJECT-TYPE
SYNTAX SEQUENCE OF FuelSensorConfigVolume
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes volume-event-specific fuel sensor attributes."
::= { fuelSensor 4 }
--1.3.6.1.4.1.3052.18.2.12.11.4
fsVolumeEntry OBJECT-TYPE
SYNTAX FuelSensorConfigVolume
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for fuel sensor volume event config table."
INDEX { fsVolumeIndex }
::= { fuelSensorVolumeTable 1 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1
fsVolumeIndex OBJECT-TYPE
SYNTAX Integer32 (1..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which fuel sensor in the fuel sensor volume event config table."
::= { fsVolumeEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.1
fsVolumeEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable fuel sensor volume events."
::= { fsVolumeEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.2
fsVolumeDeadband OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor deadband (hysteresis). This is a floating point value."
::= { fsVolumeEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.3
fsVolumeVHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor volume very high event threshold value. This is a
floating point value."
::= { fsVolumeEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.4
fsVolumeVHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor volume very high event threshold actions."
::= { fsVolumeEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.5
fsVolumeVHighTrapNum OBJECT-TYPE
SYNTAX Integer32 (519..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor volume very high event threshold trap number."
::= { fsVolumeEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.6
fsVolumeVHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor volume very high event threshold class (severity)."
::= { fsVolumeEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.7
fsVolumeHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor volume high event threshold value. This is a floating
point value."
::= { fsVolumeEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.8
fsVolumeHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor volume high event threshold actions."
::= { fsVolumeEntry 9 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.9
fsVolumeHighTrapNum OBJECT-TYPE
SYNTAX Integer32 (519..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor volume high event threshold trap number."
::= { fsVolumeEntry 10 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.10
fsVolumeHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor volume high event threshold class (severity)."
::= { fsVolumeEntry 11 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.11
fsVolumeNormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor volume return to normal actions."
::= { fsVolumeEntry 12 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.12
fsVolumeNormalTrapNum OBJECT-TYPE
SYNTAX Integer32 (519..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor volume return to normal trap number."
::= { fsVolumeEntry 13 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.13
fsVolumeNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor volume return to normal class (severity)."
::= { fsVolumeEntry 14 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.14
fsVolumeLowValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor volume low event threshold value. This is a floating
point value."
::= { fsVolumeEntry 15 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.15
fsVolumeLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor volume low event threshold actions."
::= { fsVolumeEntry 16 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.16
fsVolumeLowTrapNum OBJECT-TYPE
SYNTAX Integer32 (519..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor volume low event threshold trap number."
::= { fsVolumeEntry 17 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.17
fsVolumeLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor volume low event threshold class (severity)."
::= { fsVolumeEntry 18 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.18
fsVolumeVLowValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor volume very low event threshold value. This is a
floating point value."
::= { fsVolumeEntry 19 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.19
fsVolumeVLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor volume very low event threshold actions."
::= { fsVolumeEntry 20 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.20
fsVolumeVLowTrapNum OBJECT-TYPE
SYNTAX Integer32 (519..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor volume very low event threshold trap number."
::= { fsVolumeEntry 21 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.21
fsVolumeVLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor volume very low event threshold class (severity)."
::= { fsVolumeEntry 22 }
--1.3.6.1.4.1.3052.18.2.12.11.4.1.22
fuelSensorDisconnectTable OBJECT-TYPE
SYNTAX SEQUENCE OF FuelSensorConfigDisconnect
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes disconnect-event-specific fuel sensor attributes."
::= { fuelSensor 5 }
--1.3.6.1.4.1.3052.18.2.12.11.5
fsDiscEntry OBJECT-TYPE
SYNTAX FuelSensorConfigDisconnect
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for fuel sensor disconnect event config table."
INDEX { fsDiscIndex }
::= { fuelSensorDisconnectTable 1 }
--1.3.6.1.4.1.3052.18.2.12.11.5.1
fsDiscIndex OBJECT-TYPE
SYNTAX Integer32 (1..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which fuel sensor in the fuel sensor disconnect event config table."
::= { fsDiscEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.11.5.1.1
fsDiscEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor disconnect event enable."
::= { fsDiscEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.11.5.1.2
fsDiscHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High end of input value range when fuel sensor is disconnected. This
is in the units of the analog input value."
::= { fsDiscEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.11.5.1.3
fsDiscLowValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low end of input value range when fuel sensor is disconnected. This
is in the units of the analog input value."
::= { fsDiscEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.11.5.1.4
fsDiscActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor disconnect event actions."
::= { fsDiscEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.11.5.1.5
fsDiscTrapNum OBJECT-TYPE
SYNTAX Integer32 (515..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor disconnect event trap number."
::= { fsDiscEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.11.5.1.6
fsDiscClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor disconnect event class (severity)."
::= { fsDiscEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.11.5.1.7
fsDiscNormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor disconnect return to normal actions."
::= { fsDiscEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.11.5.1.8
fsDiscNormalTrapNum OBJECT-TYPE
SYNTAX Integer32 (515..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor disconnect return to normal trap number."
::= { fsDiscEntry 9 }
--1.3.6.1.4.1.3052.18.2.12.11.5.1.9
fsDiscNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel sensor disconnect return to normal class (severity)."
::= { fsDiscEntry 10 }
--1.3.6.1.4.1.3052.18.2.12.11.5.1.10
fuelSensorSuddenChangeTable OBJECT-TYPE
SYNTAX SEQUENCE OF FuelSensorConfigSuddenChange
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes sudden-change-event-specific fuel sensor
attributes."
::= { fuelSensor 6 }
--1.3.6.1.4.1.3052.18.2.12.11.6
fsSuddenChangeEntry OBJECT-TYPE
SYNTAX FuelSensorConfigSuddenChange
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for fuel sensor sudden change event config table."
INDEX { fsSuddenChangeIndex }
::= { fuelSensorSuddenChangeTable 1 }
--1.3.6.1.4.1.3052.18.2.12.11.6.1
fsSuddenChangeIndex OBJECT-TYPE
SYNTAX Integer32 (1..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which fuel sensor in the fuel sensor sudden change event
config table."
::= { fsSuddenChangeEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.11.6.1.1
fsSuddenChangeEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel volume sudden change event enable."
::= { fsSuddenChangeEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.11.6.1.2
fsSuddenChangeTime OBJECT-TYPE
SYNTAX Integer32 (5..360)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel volume sudden change event time (minutes): what duration defines
'sudden'."
::= { fsSuddenChangeEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.11.6.1.3
fsSuddenChangeAmplitude OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel volume sudden change event amplitude: what amount (in fuel
volume units) over the duration (fsSuddenChangeTime) defines enough
change."
::= { fsSuddenChangeEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.11.6.1.4
fsSuddenChangeActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel volume sudden change event actions."
::= { fsSuddenChangeEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.11.6.1.5
fsSuddenChangeTrapNum OBJECT-TYPE
SYNTAX Integer32 (527..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel volume sudden change event trap number."
::= { fsSuddenChangeEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.11.6.1.6
fsSuddenChangeClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel volume sudden change event class (severity)."
::= { fsSuddenChangeEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.11.6.1.7
fuelSensorSlowChangeTable OBJECT-TYPE
SYNTAX SEQUENCE OF FuelSensorConfigSlowChange
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes slow-change-event-specific fuel sensor attributes."
::= { fuelSensor 7 }
--1.3.6.1.4.1.3052.18.2.12.11.7
fsSlowChangeEntry OBJECT-TYPE
SYNTAX FuelSensorConfigSlowChange
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for fuel sensor slow change event config table."
INDEX { fsSlowChangeIndex }
::= { fuelSensorSlowChangeTable 1 }
--1.3.6.1.4.1.3052.18.2.12.11.7.1
fsSlowChangeIndex OBJECT-TYPE
SYNTAX Integer32 (1..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which fuel sensor in the fuel sensor slow change event
config table."
::= { fsSlowChangeEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.11.7.1.1
fsSlowChangeEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel volume slow change event enable."
::= { fsSlowChangeEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.11.7.1.2
fsSlowChangeTime OBJECT-TYPE
SYNTAX Integer32 (1..168)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel volume slow change event time (minutes): what duration defines
'slow'."
::= { fsSlowChangeEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.11.7.1.3
fsSlowChangeAmplitude OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel volume slow change event amplitude: what amount (in fuel volume
units) over the duration (fsSlowChangeTime) defines enough change."
::= { fsSlowChangeEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.11.7.1.4
fsSlowChangeActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel volume slow change event actions."
::= { fsSlowChangeEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.11.7.1.5
fsSlowChangeTrapNum OBJECT-TYPE
SYNTAX Integer32 (528..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel volume slow change event trap number."
::= { fsSlowChangeEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.11.7.1.6
fsSlowChangeClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fuel volume slow change event class (severity)."
::= { fsSlowChangeEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.11.7.1.7
fuelSensorLevelsAutoAdjustTable OBJECT-TYPE
SYNTAX SEQUENCE OF FuelSensorConfigLevelsAutoAdjust
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes fuel sensor attributes for levels
auto-adjustment."
::= { fuelSensor 8 }
--1.3.6.1.4.1.3052.18.2.12.11.8
fsLAAEntry OBJECT-TYPE
SYNTAX FuelSensorConfigLevelsAutoAdjust
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for fuel sensor levels auto-adjust config table."
INDEX { fsLAAIndex }
::= { fuelSensorLevelsAutoAdjustTable 1 }
--1.3.6.1.4.1.3052.18.2.12.11.8.1
fsLAAIndex OBJECT-TYPE
SYNTAX Integer32 (1..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which fuel sensor in the fuel sensor levels auto-adjust
config table."
::= { fsLAAEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.11.8.1.1
fsLAAEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable fuel sensor levels auto-adjustment."
::= { fsLAAEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.11.8.1.2
fsLAAEventEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable fuel sensor levels auto-adjust event."
::= { fsLAAEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.11.8.1.3
fsLAAEventThreshold OBJECT-TYPE
SYNTAX Integer32 (2..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets level auto-adjust event threshold as percentage of raw
value top value. In other words, the event is triggered if
the cumulative auto-adjustment, as a percentage of the
pre-adjusted value, exceeds this threshold."
::= { fsLAAEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.11.8.1.4
fsLAAEventActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for fuel sensor levels auto-adjust event."
::= { fsLAAEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.11.8.1.5
fsLAAEventClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for fuel sensor levels auto-adjust event."
::= { fsLAAEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.11.8.1.6
fsLAAEventTrapNum OBJECT-TYPE
SYNTAX Integer32 (544..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for fuel sensor levels auto-adjust event."
::= { fsLAAEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.11.8.1.7
--***************************************************************************************
--AC Power Monitor Config Section 2.12.12
--***************************************************************************************
acpmGeneralTable OBJECT-TYPE
SYNTAX SEQUENCE OF ACPMConfigGeneral
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes general AC power monitor attributes."
::= { acPowerMonitor 1 }
--1.3.6.1.4.1.3052.18.2.12.12.1
acpmGenEntry OBJECT-TYPE
SYNTAX ACPMConfigGeneral
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for AC power monitor general config table."
INDEX { acpmGenIndex }
::= { acpmGeneralTable 1 }
--1.3.6.1.4.1.3052.18.2.12.12.1.1
acpmGenIndex OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which AC power monitor in the AC power monitor general config table."
::= { acpmGenEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.12.1.1.1
acpmGenDevice OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Model of the AC power monitor device. The unit needs this setting to
know which registers to poll for the various data items, among other
things."
::= { acpmGenEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.12.1.1.2
acpmGenName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name for the AC power monitor device."
::= { acpmGenEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.12.1.1.3
acpmGenAddress OBJECT-TYPE
SYNTAX Integer32 (1..247)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Modbus address of the AC power monitor device."
::= { acpmGenEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.12.1.1.4
acpmGenPtRatio OBJECT-TYPE
SYNTAX Integer32 (1..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ratio of secondary turns to primary turns on potential transformers
(PT)."
::= { acpmGenEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.12.1.1.5
acpmGenCtRatio OBJECT-TYPE
SYNTAX Integer32 (1..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ratio of secondary turns to primary turns on current transformers
(CT)."
::= { acpmGenEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.12.1.1.6
acpmGenPowerType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Type of power being monitored."
::= { acpmGenEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.12.1.1.7
acpmGenSysrepPackage OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting package number."
::= { acpmGenEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.12.1.1.8
acpmGenSysrepType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ASM profile type."
::= { acpmGenEntry 9 }
--1.3.6.1.4.1.3052.18.2.12.12.1.1.9
acpmGenEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"AC power monitor enable."
::= { acpmGenEntry 10 }
--1.3.6.1.4.1.3052.18.2.12.12.1.1.10
acpmAvgVoltageTable OBJECT-TYPE
SYNTAX SEQUENCE OF ACPMConfigAvgVoltage
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes AC power monitor average voltage attributes."
::= { acPowerMonitor 2 }
--1.3.6.1.4.1.3052.18.2.12.12.2
acpmAvgVoltageEntry OBJECT-TYPE
SYNTAX ACPMConfigAvgVoltage
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for AC power monitor average voltage config table."
INDEX { acpmAvgVoltageIndex }
::= { acpmAvgVoltageTable 1 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1
acpmAvgVoltageIndex OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which AC power monitor in the AC power monitor average voltage config
table."
::= { acpmAvgVoltageEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.1
acpmAvgVoltageEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable AC power monitor average voltage events."
::= { acpmAvgVoltageEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.2
acpmAvgVoltageDeadband OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Deadband (hysteresis) for average voltage event. This is a floating
point value."
::= { acpmAvgVoltageEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.3
acpmAvgVoltageVHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event threshold. This is a floating point value."
::= { acpmAvgVoltageEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.4
acpmAvgVoltageVHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event actions."
::= { acpmAvgVoltageEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.5
acpmAvgVoltageVHighTrapNum OBJECT-TYPE
SYNTAX Integer32 (520..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event trap number."
::= { acpmAvgVoltageEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.6
acpmAvgVoltageVHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event class."
::= { acpmAvgVoltageEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.7
acpmAvgVoltageHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event threshold. This is a floating point value."
::= { acpmAvgVoltageEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.8
acpmAvgVoltageHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event actions."
::= { acpmAvgVoltageEntry 9 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.9
acpmAvgVoltageHighTrapNum OBJECT-TYPE
SYNTAX Integer32 (520..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event trap number."
::= { acpmAvgVoltageEntry 10 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.10
acpmAvgVoltageHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event class."
::= { acpmAvgVoltageEntry 11 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.11
acpmAvgVoltageNormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return to normal actions."
::= { acpmAvgVoltageEntry 12 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.12
acpmAvgVoltageNormalTrapNum OBJECT-TYPE
SYNTAX Integer32 (520..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return to normal trap number."
::= { acpmAvgVoltageEntry 13 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.13
acpmAvgVoltageNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return to normal class."
::= { acpmAvgVoltageEntry 14 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.14
acpmAvgVoltageLowValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event threshold. This is a floating point value."
::= { acpmAvgVoltageEntry 15 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.15
acpmAvgVoltageLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event actions."
::= { acpmAvgVoltageEntry 16 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.16
acpmAvgVoltageLowTrapNum OBJECT-TYPE
SYNTAX Integer32 (520..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event trap number."
::= { acpmAvgVoltageEntry 17 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.17
acpmAvgVoltageLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event class."
::= { acpmAvgVoltageEntry 18 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.18
acpmAvgVoltageVLowValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event threshold. This is a floating point value."
::= { acpmAvgVoltageEntry 19 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.19
acpmAvgVoltageVLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event actions."
::= { acpmAvgVoltageEntry 20 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.20
acpmAvgVoltageVLowTrapNum OBJECT-TYPE
SYNTAX Integer32 (520..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event trap number."
::= { acpmAvgVoltageEntry 21 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.21
acpmAvgVoltageVLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event class."
::= { acpmAvgVoltageEntry 22 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.22
acpmAvgVoltageSysrepEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting enable for average voltage telemetry."
::= { acpmAvgVoltageEntry 23 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.23
acpmAvgVoltageSysrepThreshold OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting threshold for average voltage telemetry. This is a
floating point value."
::= { acpmAvgVoltageEntry 24 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.24
acpmAvgVoltageSysrepLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting limit for average voltage telemetry."
::= { acpmAvgVoltageEntry 25 }
--1.3.6.1.4.1.3052.18.2.12.12.2.1.25
acpmAvgCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF ACPMConfigAvgCurrent
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes AC power monitor average current attributes."
::= { acPowerMonitor 3 }
--1.3.6.1.4.1.3052.18.2.12.12.3
acpmAvgCurrentEntry OBJECT-TYPE
SYNTAX ACPMConfigAvgCurrent
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for AC power monitor average current config table."
INDEX { acpmAvgCurrentIndex }
::= { acpmAvgCurrentTable 1 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1
acpmAvgCurrentIndex OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which AC power monitor in the AC power monitor average current config
table."
::= { acpmAvgCurrentEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.1
acpmAvgCurrentEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable AC power monitor average current events."
::= { acpmAvgCurrentEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.2
acpmAvgCurrentDeadband OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Deadband (hysteresis) for average current event. This is a floating
point value."
::= { acpmAvgCurrentEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.3
acpmAvgCurrentVHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event threshold. This is a floating point value."
::= { acpmAvgCurrentEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.4
acpmAvgCurrentVHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event actions."
::= { acpmAvgCurrentEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.5
acpmAvgCurrentVHighTrapNum OBJECT-TYPE
SYNTAX Integer32 (521..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event trap number."
::= { acpmAvgCurrentEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.6
acpmAvgCurrentVHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event class."
::= { acpmAvgCurrentEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.7
acpmAvgCurrentHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event threshold. This is a floating point value."
::= { acpmAvgCurrentEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.8
acpmAvgCurrentHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event actions."
::= { acpmAvgCurrentEntry 9 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.9
acpmAvgCurrentHighTrapNum OBJECT-TYPE
SYNTAX Integer32 (521..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event trap number."
::= { acpmAvgCurrentEntry 10 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.10
acpmAvgCurrentHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event class."
::= { acpmAvgCurrentEntry 11 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.11
acpmAvgCurrentNormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return to normal actions."
::= { acpmAvgCurrentEntry 12 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.12
acpmAvgCurrentNormalTrapNum OBJECT-TYPE
SYNTAX Integer32 (521..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return to normal trap number."
::= { acpmAvgCurrentEntry 13 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.13
acpmAvgCurrentNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return to normal class."
::= { acpmAvgCurrentEntry 14 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.14
acpmAvgCurrentLowValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event threshold. This is a floating point value."
::= { acpmAvgCurrentEntry 15 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.15
acpmAvgCurrentLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event actions."
::= { acpmAvgCurrentEntry 16 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.16
acpmAvgCurrentLowTrapNum OBJECT-TYPE
SYNTAX Integer32 (521..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event trap number."
::= { acpmAvgCurrentEntry 17 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.17
acpmAvgCurrentLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event class."
::= { acpmAvgCurrentEntry 18 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.18
acpmAvgCurrentVLowValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event threshold. This is a floating point value."
::= { acpmAvgCurrentEntry 19 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.19
acpmAvgCurrentVLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event actions."
::= { acpmAvgCurrentEntry 20 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.20
acpmAvgCurrentVLowTrapNum OBJECT-TYPE
SYNTAX Integer32 (521..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event trap number."
::= { acpmAvgCurrentEntry 21 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.21
acpmAvgCurrentVLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event class."
::= { acpmAvgCurrentEntry 22 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.22
acpmAvgCurrentSysrepEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting enable for average current telemetry."
::= { acpmAvgCurrentEntry 23 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.23
acpmAvgCurrentSysrepThreshold OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting threshold for average current telemetry. This is
a floating point value."
::= { acpmAvgCurrentEntry 24 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.24
acpmAvgCurrentSysrepLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting limit for average current telemetry."
::= { acpmAvgCurrentEntry 25 }
--1.3.6.1.4.1.3052.18.2.12.12.3.1.25
acpmFreqTable OBJECT-TYPE
SYNTAX SEQUENCE OF ACPMConfigFreq
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes AC power monitor frequency attributes."
::= { acPowerMonitor 4 }
--1.3.6.1.4.1.3052.18.2.12.12.4
acpmFreqEntry OBJECT-TYPE
SYNTAX ACPMConfigFreq
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for AC power monitor frequency config table."
INDEX { acpmFreqIndex }
::= { acpmFreqTable 1 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1
acpmFreqIndex OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which AC power monitor in the AC power monitor frequency config table."
::= { acpmFreqEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.1
acpmFreqEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable AC power monitor frequency events."
::= { acpmFreqEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.2
acpmFreqDeadband OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Deadband (hysteresis) for frequency event. This is a floating point
value."
::= { acpmFreqEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.3
acpmFreqVHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event threshold. This is a floating point value."
::= { acpmFreqEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.4
acpmFreqVHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event actions."
::= { acpmFreqEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.5
acpmFreqVHighTrapNum OBJECT-TYPE
SYNTAX Integer32 (522..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event trap number."
::= { acpmFreqEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.6
acpmFreqVHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event class."
::= { acpmFreqEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.7
acpmFreqHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event threshold. This is a floating point value."
::= { acpmFreqEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.8
acpmFreqHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event actions."
::= { acpmFreqEntry 9 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.9
acpmFreqHighTrapNum OBJECT-TYPE
SYNTAX Integer32 (522..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event trap number."
::= { acpmFreqEntry 10 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.10
acpmFreqHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event class."
::= { acpmFreqEntry 11 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.11
acpmFreqNormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return to normal actions."
::= { acpmFreqEntry 12 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.12
acpmFreqNormalTrapNum OBJECT-TYPE
SYNTAX Integer32 (522..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return to normal trap number."
::= { acpmFreqEntry 13 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.13
acpmFreqNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return to normal class."
::= { acpmFreqEntry 14 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.14
acpmFreqLowValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event threshold. This is a floating point value."
::= { acpmFreqEntry 15 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.15
acpmFreqLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event actions."
::= { acpmFreqEntry 16 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.16
acpmFreqLowTrapNum OBJECT-TYPE
SYNTAX Integer32 (522..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event trap number."
::= { acpmFreqEntry 17 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.17
acpmFreqLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event class."
::= { acpmFreqEntry 18 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.18
acpmFreqVLowValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event threshold. This is a floating point value."
::= { acpmFreqEntry 19 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.19
acpmFreqVLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event actions."
::= { acpmFreqEntry 20 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.20
acpmFreqVLowTrapNum OBJECT-TYPE
SYNTAX Integer32 (522..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event trap number."
::= { acpmFreqEntry 21 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.21
acpmFreqVLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event class."
::= { acpmFreqEntry 22 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.22
acpmFreqSysrepEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting enable for frequency telemetry."
::= { acpmFreqEntry 23 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.23
acpmFreqSysrepThreshold OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting threshold for frequency telemetry. This is a
floating point value."
::= { acpmFreqEntry 24 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.24
acpmFreqSysrepLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting limit for frequency telemetry."
::= { acpmFreqEntry 25 }
--1.3.6.1.4.1.3052.18.2.12.12.4.1.25
acpmTotalRealPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF ACPMConfigTRP
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes AC power monitor total real power attributes."
::= { acPowerMonitor 5 }
--1.3.6.1.4.1.3052.18.2.12.12.5
acpmTRPEntry OBJECT-TYPE
SYNTAX ACPMConfigTRP
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for AC power monitor total real power config table."
INDEX { acpmTRPIndex }
::= { acpmTotalRealPowerTable 1 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1
acpmTRPIndex OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which AC power monitor in the AC power monitor total real power
config table."
::= { acpmTRPEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.1
acpmTRPEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable AC power monitor total real power events."
::= { acpmTRPEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.2
acpmTRPDeadband OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Deadband (hysteresis) for total real power event. This is a
floating point value."
::= { acpmTRPEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.3
acpmTRPVHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event threshold. This is a floating point value."
::= { acpmTRPEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.4
acpmTRPVHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event actions."
::= { acpmTRPEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.5
acpmTRPVHighTrapNum OBJECT-TYPE
SYNTAX Integer32 (523..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event trap number."
::= { acpmTRPEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.6
acpmTRPVHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event class."
::= { acpmTRPEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.7
acpmTRPHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event threshold. This is a floating point value."
::= { acpmTRPEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.8
acpmTRPHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event actions."
::= { acpmTRPEntry 9 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.9
acpmTRPHighTrapNum OBJECT-TYPE
SYNTAX Integer32 (523..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event trap number."
::= { acpmTRPEntry 10 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.10
acpmTRPHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event class."
::= { acpmTRPEntry 11 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.11
acpmTRPNormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return to normal actions."
::= { acpmTRPEntry 12 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.12
acpmTRPNormalTrapNum OBJECT-TYPE
SYNTAX Integer32 (523..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return to normal trap number."
::= { acpmTRPEntry 13 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.13
acpmTRPNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Return to normal class."
::= { acpmTRPEntry 14 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.14
acpmTRPLowValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event threshold. This is a floating point value."
::= { acpmTRPEntry 15 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.15
acpmTRPLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event actions."
::= { acpmTRPEntry 16 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.16
acpmTRPLowTrapNum OBJECT-TYPE
SYNTAX Integer32 (523..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event trap number."
::= { acpmTRPEntry 17 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.17
acpmTRPLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event class."
::= { acpmTRPEntry 18 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.18
acpmTRPVLowValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event threshold. This is a floating point value."
::= { acpmTRPEntry 19 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.19
acpmTRPVLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event actions."
::= { acpmTRPEntry 20 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.20
acpmTRPVLowTrapNum OBJECT-TYPE
SYNTAX Integer32 (523..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event trap number."
::= { acpmTRPEntry 21 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.21
acpmTRPVLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very low event class."
::= { acpmTRPEntry 22 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.22
acpmTRPSysrepEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting enable for total real power telemetry."
::= { acpmTRPEntry 23 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.23
acpmTRPSysrepThreshold OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting threshold for total real power telemetry. This is a
floating point value."
::= { acpmTRPEntry 24 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.24
acpmTRPSysrepLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting limit for total real power telemetry."
::= { acpmTRPEntry 25 }
--1.3.6.1.4.1.3052.18.2.12.12.5.1.25
acpmDisconnectTable OBJECT-TYPE
SYNTAX SEQUENCE OF ACPMConfigDisconnect
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes AC power monitor device disconnect event
attributes."
::= { acPowerMonitor 6 }
--1.3.6.1.4.1.3052.18.2.12.12.6
acpmDisconnectEntry OBJECT-TYPE
SYNTAX ACPMConfigDisconnect
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for AC power monitor device disconnect event config table."
INDEX { acpmDisconnectIndex }
::= { acpmDisconnectTable 1 }
--1.3.6.1.4.1.3052.18.2.12.12.6.1
acpmDisconnectIndex OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which AC power monitor in the AC power monitor device disconnect event
config table."
::= { acpmDisconnectEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.12.6.1.1
acpmDisconnectEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable AC power monitor device disconnect event."
::= { acpmDisconnectEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.12.6.1.2
acpmDisconnectActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for disconnect event."
::= { acpmDisconnectEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.12.6.1.3
acpmDisconnectTrapNum OBJECT-TYPE
SYNTAX Integer32 (524..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for disconnect event."
::= { acpmDisconnectEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.12.6.1.4
acpmDisconnectClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for disconnect event."
::= { acpmDisconnectEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.12.6.1.5
acpmDisconnectNormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for disconnect return to normal event."
::= { acpmDisconnectEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.12.6.1.6
acpmDisconnectNormalTrapNum OBJECT-TYPE
SYNTAX Integer32 (524..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for disconnect return to normal event."
::= { acpmDisconnectEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.12.6.1.7
acpmDisconnectNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for disconnect return to normal event."
::= { acpmDisconnectEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.12.6.1.8
acpmTotalPowerFactorTable OBJECT-TYPE
SYNTAX SEQUENCE OF ACPMConfigTotalPowerFactor
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes AC power monitor device total power factor
event attributes."
::= { acPowerMonitor 7 }
--1.3.6.1.4.1.3052.18.2.12.12.7
acpmTPFEntry OBJECT-TYPE
SYNTAX ACPMConfigTotalPowerFactor
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for AC power monitor device total power factor event config
table."
INDEX { acpmTPFIndex }
::= { acpmTotalPowerFactorTable 1 }
--1.3.6.1.4.1.3052.18.2.12.12.7.1
acpmTPFIndex OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which AC power monitor in the AC power monitor device disconnect
event config table."
::= { acpmTPFEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.12.7.1.1
acpmTPFEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable AC power monitor device disconnect event."
::= { acpmTPFEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.12.7.1.2
acpmTPFDeadband OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Deadband (hysteresis)."
::= { acpmTPFEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.12.7.1.3
acpmTPFNormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Normal actions."
::= { acpmTPFEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.12.7.1.4
acpmTPFNormalTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Normal trap number."
::= { acpmTPFEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.12.7.1.5
acpmTPFNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Normal class."
::= { acpmTPFEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.12.7.1.6
acpmTPFLowValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low threshold."
::= { acpmTPFEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.12.7.1.7
acpmTPFLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low actions."
::= { acpmTPFEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.12.7.1.8
acpmTPFLowTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low trap number."
::= { acpmTPFEntry 9 }
--1.3.6.1.4.1.3052.18.2.12.12.7.1.9
acpmTPFLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low class."
::= { acpmTPFEntry 10 }
--1.3.6.1.4.1.3052.18.2.12.12.7.1.10
acpmTPFVLowValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very Low threshold."
::= { acpmTPFEntry 11 }
--1.3.6.1.4.1.3052.18.2.12.12.7.1.11
acpmTPFVLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very Low actions."
::= { acpmTPFEntry 12 }
--1.3.6.1.4.1.3052.18.2.12.12.7.1.12
acpmTPFVLowTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very Low trap number."
::= { acpmTPFEntry 13 }
--1.3.6.1.4.1.3052.18.2.12.12.7.1.13
acpmTPFVLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very Low class."
::= { acpmTPFEntry 14 }
--1.3.6.1.4.1.3052.18.2.12.12.7.1.14
acpmTPFSysrepEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting enable."
::= { acpmTPFEntry 15 }
--1.3.6.1.4.1.3052.18.2.12.12.7.1.15
acpmTPFSysrepThreshold OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting threshold."
::= { acpmTPFEntry 16 }
--1.3.6.1.4.1.3052.18.2.12.12.7.1.16
acpmTPFSysrepLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting limit."
::= { acpmTPFEntry 17 }
--1.3.6.1.4.1.3052.18.2.12.12.7.1.17
--***************************************************************************************
--Battery Monitor Config Section 2.12.14
--***************************************************************************************
batteryMonitorGeneralTable OBJECT-TYPE
SYNTAX SEQUENCE OF BatteryMonitorConfigGeneral
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes general battery monitor attributes."
::= { batteryMonitor 1 }
--1.3.6.1.4.1.3052.18.2.12.14.1
bmGenEntry OBJECT-TYPE
SYNTAX BatteryMonitorConfigGeneral
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for battery monitor general config table."
INDEX { bmGenIndex }
::= { batteryMonitorGeneralTable 1 }
--1.3.6.1.4.1.3052.18.2.12.14.1.1
bmGenIndex OBJECT-TYPE
SYNTAX Integer32 (1..9)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which battery monitor in the battery monitor general config table."
::= { bmGenEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.14.1.1.1
bmGenEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Which battery monitor in the battery monitor general config table."
::= { bmGenEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.14.1.1.2
bmGenName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name for this battery monitor."
::= { bmGenEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.14.1.1.3
bmGenBatteryQuantity OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of batteries in the string."
::= { bmGenEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.14.1.1.4
bmGenBatteryCapacity OBJECT-TYPE
SYNTAX Integer32 (5..500)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Capacity of the individual batteries in the string, in amp-hours. A
single value applies to all batteries; that is, they are assumed to be
all of the same capacity."
::= { bmGenEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.14.1.1.5
bmGenBatteryNominalVoltage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Nominal voltage of the individual batteries in the string, in volts.
A single value applies to all batteres; that is, they are assumed to
be all of the same voltage. This is a floating point value."
::= { bmGenEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.14.1.1.6
bmGenSysrepPackage OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting package number."
::= { bmGenEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.14.1.1.7
bmGenSysrepType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting ASM profile type."
::= { bmGenEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.14.1.1.8
batteryMonitorDeviceTable OBJECT-TYPE
SYNTAX SEQUENCE OF BatteryMonitorConfigDevice
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes temperature battery monitor attributes."
::= { batteryMonitor 2 }
--1.3.6.1.4.1.3052.18.2.12.14.2
bmDeviceEntry OBJECT-TYPE
SYNTAX BatteryMonitorConfigDevice
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for battery monitor temperature config table."
INDEX { bmDeviceIndex }
::= { batteryMonitorDeviceTable 1 }
--1.3.6.1.4.1.3052.18.2.12.14.2.1
bmDeviceIndex OBJECT-TYPE
SYNTAX Integer32 (1..9)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which battery monitor in the battery monitor device config table."
::= { bmDeviceEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.14.2.1.1
bmDeviceType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of hardware battery monitor unit associated with this battery
monitor."
::= { bmDeviceEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.14.2.1.2
bmDeviceES OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ES index of the hardware battery monitor unit associated with this
battery monitor. This setting only pertains to the ES-BMU."
::= { bmDeviceEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.14.2.1.3
bmDeviceIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the hardware battery monitor unit associated with
this battery monitor."
::= { bmDeviceEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.14.2.1.4
bmDeviceReadcom OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SNMP read community of the hardware battery monitor unit
associated with this battery monitor."
::= { bmDeviceEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.14.2.1.5
bmDeviceInputString OBJECT-TYPE
SYNTAX Integer32 (1..3)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Which string on the hardware battery monitor unit is
associated with this battery monitor. "
::= { bmDeviceEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.14.2.1.6
bmDeviceCTSize OBJECT-TYPE
SYNTAX Integer32 (0..999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The rating of the DC current sensor, in amperes. If this value is set
to 0, then string current will not be measured. This setting only
pertains to the ES-BMU."
::= { bmDeviceEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.14.2.1.7
batteryMonitorTempTable OBJECT-TYPE
SYNTAX SEQUENCE OF BatteryMonitorConfigTemp
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes temperature battery monitor attributes."
::= { batteryMonitor 3 }
--1.3.6.1.4.1.3052.18.2.12.14.3
bmTempEntry OBJECT-TYPE
SYNTAX BatteryMonitorConfigTemp
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for battery monitor temperature config table."
INDEX { bmTempIndex }
::= { batteryMonitorTempTable 1 }
--1.3.6.1.4.1.3052.18.2.12.14.3.1
bmTempIndex OBJECT-TYPE
SYNTAX Integer32 (1..9)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which battery monitor in the battery monitor temperature config table."
::= { bmTempEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.14.3.1.1
bmTempEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable temperature event. This event is based on the average
temperature of the jars in the string."
::= { bmTempEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.14.3.1.2
bmTempDeadband OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Deadband in degrees F or C, depending on scale setting of sensor
referenced by bmGenDeviceES. This is a floating point value."
::= { bmTempEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.14.3.1.3
bmTempScale OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Temperature scale; this affects how temperature values are
represented, and also how the temperature alarm thresholds and
deadbands are interpreted."
::= { bmTempEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.14.3.1.4
bmTempHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event threshold in degrees F or C, depending on scale
setting referenced by bmGenDeviceES. This is a floating point value."
::= { bmTempEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.14.3.1.5
bmTempHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for very high temperature event."
::= { bmTempEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.14.3.1.6
bmTempHighTrapNum OBJECT-TYPE
SYNTAX Integer32 (530..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for high temperature event."
::= { bmTempEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.14.3.1.7
bmTempHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for high temperature event."
::= { bmTempEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.14.3.1.8
bmTempNormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for return to normal temperature event."
::= { bmTempEntry 9 }
--1.3.6.1.4.1.3052.18.2.12.14.3.1.9
bmTempNormalTrapNum OBJECT-TYPE
SYNTAX Integer32 (530..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for return to normal temperature event."
::= { bmTempEntry 10 }
--1.3.6.1.4.1.3052.18.2.12.14.3.1.10
bmTempNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for return to normal temperature event."
::= { bmTempEntry 11 }
--1.3.6.1.4.1.3052.18.2.12.14.3.1.11
bmTempLowValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event threshold in degrees F or C, depending on scale setting.
This is a floating point value."
::= { bmTempEntry 12 }
--1.3.6.1.4.1.3052.18.2.12.14.3.1.12
bmTempLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for low temperature event."
::= { bmTempEntry 13 }
--1.3.6.1.4.1.3052.18.2.12.14.3.1.13
bmTempLowTrapNum OBJECT-TYPE
SYNTAX Integer32 (530..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for low temperature event."
::= { bmTempEntry 14 }
--1.3.6.1.4.1.3052.18.2.12.14.3.1.14
bmTempLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for low temperature event."
::= { bmTempEntry 15 }
--1.3.6.1.4.1.3052.18.2.12.14.3.1.15
bmTempSysrepEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting enable for temperature telemetry."
::= { bmTempEntry 16 }
--1.3.6.1.4.1.3052.18.2.12.14.3.1.16
bmTempSysrepThreshold OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting threshold for temperature telemetry. This is a
floating point value."
::= { bmTempEntry 17 }
--1.3.6.1.4.1.3052.18.2.12.14.3.1.17
bmTempSysrepLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting limit for temperature telemetry."
::= { bmTempEntry 18 }
--1.3.6.1.4.1.3052.18.2.12.14.3.1.18
batteryMonitorDiffTempTable OBJECT-TYPE
SYNTAX SEQUENCE OF BatteryMonitorConfigDiffTemp
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes differential temperature battery monitor
attributes."
::= { batteryMonitor 4 }
--1.3.6.1.4.1.3052.18.2.12.14.4
bmDiffTempEntry OBJECT-TYPE
SYNTAX BatteryMonitorConfigDiffTemp
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for battery monitor differential temperature config table."
INDEX { bmDiffTempIndex }
::= { batteryMonitorDiffTempTable 1 }
--1.3.6.1.4.1.3052.18.2.12.14.4.1
bmDiffTempIndex OBJECT-TYPE
SYNTAX Integer32 (1..9)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which battery monitor in the battery monitor differential
temperature config table."
::= { bmDiffTempEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.14.4.1.1
bmDiffTempEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable differential temperature event. This event is based on
the differential between the average temperature of the batteries in
the string, and ambient temperature (ambient - string temperature)."
::= { bmDiffTempEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.14.4.1.2
bmDiffTempDeadband OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Deadband in degrees F or C, depending on scale setting."
::= { bmDiffTempEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.14.4.1.3
bmDiffTempVHighValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event threshold in degrees F or C, depending on scale
setting."
::= { bmDiffTempEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.14.4.1.4
bmDiffTempVHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for very high differential temperature event."
::= { bmDiffTempEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.14.4.1.5
bmDiffTempVHighTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for very high differential temperature event."
::= { bmDiffTempEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.14.4.1.6
bmDiffTempVHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for very high differential temperature event."
::= { bmDiffTempEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.14.4.1.7
bmDiffTempHighValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event threshold in degrees F or C, depending on scale setting."
::= { bmDiffTempEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.14.4.1.8
bmDiffTempHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for high differential temperature event."
::= { bmDiffTempEntry 9 }
--1.3.6.1.4.1.3052.18.2.12.14.4.1.9
bmDiffTempHighTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for high differential temperature event."
::= { bmDiffTempEntry 10 }
--1.3.6.1.4.1.3052.18.2.12.14.4.1.10
bmDiffTempHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for high differential temperature event."
::= { bmDiffTempEntry 11 }
--1.3.6.1.4.1.3052.18.2.12.14.4.1.11
bmDiffTempNormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for return to normal differential temperature event."
::= { bmDiffTempEntry 12 }
--1.3.6.1.4.1.3052.18.2.12.14.4.1.12
bmDiffTempNormalTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for return to normal differential temperature event."
::= { bmDiffTempEntry 13 }
--1.3.6.1.4.1.3052.18.2.12.14.4.1.13
bmDiffTempNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for return to normal differential temperature event."
::= { bmDiffTempEntry 14 }
--1.3.6.1.4.1.3052.18.2.12.14.4.1.14
bmDiffTempSysrepEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting enable for differential temperature telemetry."
::= { bmDiffTempEntry 15 }
--1.3.6.1.4.1.3052.18.2.12.14.4.1.15
bmDiffTempSysrepThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting threshold for differential temperature telemetry."
::= { bmDiffTempEntry 16 }
--1.3.6.1.4.1.3052.18.2.12.14.4.1.16
bmDiffTempSysrepLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting limit for differential temperature telemetry."
::= { bmDiffTempEntry 17 }
--1.3.6.1.4.1.3052.18.2.12.14.4.1.17
batteryMonitorVoltageTable OBJECT-TYPE
SYNTAX SEQUENCE OF BatteryMonitorConfigVoltage
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes battery monitor voltage attributes."
::= { batteryMonitor 5 }
--1.3.6.1.4.1.3052.18.2.12.14.5
bmVoltageEntry OBJECT-TYPE
SYNTAX BatteryMonitorConfigVoltage
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for battery monitor voltage config table."
INDEX { bmVoltageIndex }
::= { batteryMonitorVoltageTable 1 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1
bmVoltageIndex OBJECT-TYPE
SYNTAX Integer32 (1..9)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which battery monitor in the battery monitor voltage config table."
::= { bmVoltageEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.1
bmVoltageEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable voltage event. This event is based on the total
voltage output of the batteries in the string."
::= { bmVoltageEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.2
bmVoltageDeadband OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Deadband in volts. This is a floating point value."
::= { bmVoltageEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.3
bmVoltageVHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event threshold, in volts. This is a floating point value."
::= { bmVoltageEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.4
bmVoltageVHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for very high voltage event."
::= { bmVoltageEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.5
bmVoltageVHighTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for very high voltage event."
::= { bmVoltageEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.6
bmVoltageVHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for very high voltage event."
::= { bmVoltageEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.7
bmVoltageHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event threshold, in volts. This is a floating point value."
::= { bmVoltageEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.8
bmVoltageHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for high voltage event."
::= { bmVoltageEntry 9 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.9
bmVoltageHighTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for high voltage event."
::= { bmVoltageEntry 10 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.10
bmVoltageHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for high voltage event."
::= { bmVoltageEntry 11 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.11
bmVoltageNormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for return to normal voltage event."
::= { bmVoltageEntry 12 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.12
bmVoltageNormalTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for return to normal voltage event."
::= { bmVoltageEntry 13 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.13
bmVoltageNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for return to normal voltage event."
::= { bmVoltageEntry 14 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.14
bmVoltageLowValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low event threshold, in volts. This is a floating point value."
::= { bmVoltageEntry 15 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.15
bmVoltageLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for low voltage event."
::= { bmVoltageEntry 16 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.16
bmVoltageLowTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for low voltage event."
::= { bmVoltageEntry 17 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.17
bmVoltageLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for low voltage event."
::= { bmVoltageEntry 18 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.18
bmVoltageVLowValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very Low event threshold, in volts. This is a floating point value."
::= { bmVoltageEntry 19 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.19
bmVoltageVLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for very low voltage event."
::= { bmVoltageEntry 20 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.20
bmVoltageVLowTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for very low voltage event."
::= { bmVoltageEntry 21 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.21
bmVoltageVLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for very low voltage event."
::= { bmVoltageEntry 22 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.22
bmVoltageSysrepEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting enable for voltage telemetry."
::= { bmVoltageEntry 23 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.23
bmVoltageSysrepThreshold OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting threshold for voltage telemetry. This is a floating
point value."
::= { bmVoltageEntry 24 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.24
bmVoltageSysrepLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting limit for voltage telemetry."
::= { bmVoltageEntry 25 }
--1.3.6.1.4.1.3052.18.2.12.14.5.1.25
batteryMonitorDiffVoltTable OBJECT-TYPE
SYNTAX SEQUENCE OF BatteryMonitorConfigDiffVolt
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes differential voltage battery monitor
attributes."
::= { batteryMonitor 6 }
--1.3.6.1.4.1.3052.18.2.12.14.6
bmDiffVoltEntry OBJECT-TYPE
SYNTAX BatteryMonitorConfigDiffVolt
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for battery monitor differential voltage config table."
INDEX { bmDiffVoltIndex }
::= { batteryMonitorDiffVoltTable 1 }
--1.3.6.1.4.1.3052.18.2.12.14.6.1
bmDiffVoltIndex OBJECT-TYPE
SYNTAX Integer32 (1..9)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which battery monitor in the battery monitor differential
voltage config table."
::= { bmDiffVoltEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.14.6.1.1
bmDiffVoltEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable differential voltage event. This event is based on
the differential between the highest and lowest jar voltages within
the string."
::= { bmDiffVoltEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.14.6.1.2
bmDiffVoltDeadband OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Deadband in volts."
::= { bmDiffVoltEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.14.6.1.3
bmDiffVoltVHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event threshold in volts. This is a floating point value."
::= { bmDiffVoltEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.14.6.1.4
bmDiffVoltVHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for very high differential voltage event."
::= { bmDiffVoltEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.14.6.1.5
bmDiffVoltVHighTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for very high differential voltage event."
::= { bmDiffVoltEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.14.6.1.6
bmDiffVoltVHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for very high differential voltage event."
::= { bmDiffVoltEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.14.6.1.7
bmDiffVoltHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event threshold in volts. This is a floating point value."
::= { bmDiffVoltEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.14.6.1.8
bmDiffVoltHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for high differential voltage event."
::= { bmDiffVoltEntry 9 }
--1.3.6.1.4.1.3052.18.2.12.14.6.1.9
bmDiffVoltHighTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for high differential voltage event."
::= { bmDiffVoltEntry 10 }
--1.3.6.1.4.1.3052.18.2.12.14.6.1.10
bmDiffVoltHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for high differential voltage event."
::= { bmDiffVoltEntry 11 }
--1.3.6.1.4.1.3052.18.2.12.14.6.1.11
bmDiffVoltNormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for return to normal differential voltage event."
::= { bmDiffVoltEntry 12 }
--1.3.6.1.4.1.3052.18.2.12.14.6.1.12
bmDiffVoltNormalTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for return to normal differential voltage event."
::= { bmDiffVoltEntry 13 }
--1.3.6.1.4.1.3052.18.2.12.14.6.1.13
bmDiffVoltNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for return to normal differential voltage event."
::= { bmDiffVoltEntry 14 }
--1.3.6.1.4.1.3052.18.2.12.14.6.1.14
bmDiffVoltSysrepEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting enable for differential voltage telemetry."
::= { bmDiffVoltEntry 15 }
--1.3.6.1.4.1.3052.18.2.12.14.6.1.15
bmDiffVoltSysrepThreshold OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting threshold for differential voltage telemetry."
::= { bmDiffVoltEntry 16 }
--1.3.6.1.4.1.3052.18.2.12.14.6.1.16
bmDiffVoltSysrepLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting limit for differential voltage telemetry."
::= { bmDiffVoltEntry 17 }
--1.3.6.1.4.1.3052.18.2.12.14.6.1.17
batteryMonitorChargingCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF BatteryMonitorConfigChargingCurrent
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes battery monitor charging current attributes."
::= { batteryMonitor 7 }
--1.3.6.1.4.1.3052.18.2.12.14.7
bmChargingCurrentEntry OBJECT-TYPE
SYNTAX BatteryMonitorConfigChargingCurrent
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for battery monitor differential charging current config table."
INDEX { bmChargingCurrentIndex }
::= { batteryMonitorChargingCurrentTable 1 }
--1.3.6.1.4.1.3052.18.2.12.14.7.1
bmChargingCurrentIndex OBJECT-TYPE
SYNTAX Integer32 (1..9)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which battery monitor in the battery monitor charging current config table."
::= { bmChargingCurrentEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.14.7.1.1
bmChargingCurrentEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable charging current event. This event is based on
positive current flow (i.e. current flowing into the battery string)."
::= { bmChargingCurrentEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.14.7.1.2
bmChargingCurrentDeadband OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Deadband in amperes. This is a floating point value."
::= { bmChargingCurrentEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.14.7.1.3
bmChargingCurrentVHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event threshold, in volts. This is a floating point value."
::= { bmChargingCurrentEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.14.7.1.4
bmChargingCurrentVHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for very high charging current event."
::= { bmChargingCurrentEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.14.7.1.5
bmChargingCurrentVHighTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for very high charging current event."
::= { bmChargingCurrentEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.14.7.1.6
bmChargingCurrentVHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for very high charging current event."
::= { bmChargingCurrentEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.14.7.1.7
bmChargingCurrentHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event threshold, in volts. This is a floating point value."
::= { bmChargingCurrentEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.14.7.1.8
bmChargingCurrentHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for high charging current event."
::= { bmChargingCurrentEntry 9 }
--1.3.6.1.4.1.3052.18.2.12.14.7.1.9
bmChargingCurrentHighTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for high charging current event."
::= { bmChargingCurrentEntry 10 }
--1.3.6.1.4.1.3052.18.2.12.14.7.1.10
bmChargingCurrentHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for high charging current event."
::= { bmChargingCurrentEntry 11 }
--1.3.6.1.4.1.3052.18.2.12.14.7.1.11
bmChargingCurrentNormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for return to normal charging current event."
::= { bmChargingCurrentEntry 12 }
--1.3.6.1.4.1.3052.18.2.12.14.7.1.12
bmChargingCurrentNormalTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for return to normal charging current event."
::= { bmChargingCurrentEntry 13 }
--1.3.6.1.4.1.3052.18.2.12.14.7.1.13
bmChargingCurrentNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for return to normal charging current event."
::= { bmChargingCurrentEntry 14 }
--1.3.6.1.4.1.3052.18.2.12.14.7.1.14
bmChargingCurrentSysrepEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting enable for charging current telemetry."
::= { bmChargingCurrentEntry 15 }
--1.3.6.1.4.1.3052.18.2.12.14.7.1.15
bmChargingCurrentSysrepThreshold OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting threshold for charging current telemetry. This is a
floating point value."
::= { bmChargingCurrentEntry 16 }
--1.3.6.1.4.1.3052.18.2.12.14.7.1.16
bmChargingCurrentSysrepLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting limit for charging current telemetry."
::= { bmChargingCurrentEntry 17 }
--1.3.6.1.4.1.3052.18.2.12.14.7.1.17
batteryMonitorDischargingCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF BatteryMonitorConfigDischargingCurrent
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes battery monitor discharging current attributes."
::= { batteryMonitor 8 }
--1.3.6.1.4.1.3052.18.2.12.14.8
bmDischargingCurrentEntry OBJECT-TYPE
SYNTAX BatteryMonitorConfigDischargingCurrent
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for battery monitor differential discharging current config
table."
INDEX { bmDischargingCurrentIndex }
::= { batteryMonitorDischargingCurrentTable 1 }
--1.3.6.1.4.1.3052.18.2.12.14.8.1
bmDischargingCurrentIndex OBJECT-TYPE
SYNTAX Integer32 (1..9)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which battery monitor in the battery monitor discharging current
config table."
::= { bmDischargingCurrentEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.14.8.1.1
bmDischargingCurrentEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable discharging current event. This event is based on
positive current flow (i.e. current flowing into the battery string)."
::= { bmDischargingCurrentEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.14.8.1.2
bmDischargingCurrentDeadband OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Deadband in amperes. This is a floating point value."
::= { bmDischargingCurrentEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.14.8.1.3
bmDischargingCurrentVHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Very high event threshold, in volts. This is a floating point value."
::= { bmDischargingCurrentEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.14.8.1.4
bmDischargingCurrentVHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for very high discharging current event."
::= { bmDischargingCurrentEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.14.8.1.5
bmDischargingCurrentVHighTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for very high discharging current event."
::= { bmDischargingCurrentEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.14.8.1.6
bmDischargingCurrentVHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for very high discharging current event."
::= { bmDischargingCurrentEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.14.8.1.7
bmDischargingCurrentHighValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High event threshold, in volts. This is a floating point value."
::= { bmDischargingCurrentEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.14.8.1.8
bmDischargingCurrentHighActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for high discharging current event."
::= { bmDischargingCurrentEntry 9 }
--1.3.6.1.4.1.3052.18.2.12.14.8.1.9
bmDischargingCurrentHighTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for high discharging current event."
::= { bmDischargingCurrentEntry 10 }
--1.3.6.1.4.1.3052.18.2.12.14.8.1.10
bmDischargingCurrentHighClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for high discharging current event."
::= { bmDischargingCurrentEntry 11 }
--1.3.6.1.4.1.3052.18.2.12.14.8.1.11
bmDischargingCurrentNormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for return to normal discharging current event."
::= { bmDischargingCurrentEntry 12 }
--1.3.6.1.4.1.3052.18.2.12.14.8.1.12
bmDischargingCurrentNormalTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for return to normal discharging current event."
::= { bmDischargingCurrentEntry 13 }
--1.3.6.1.4.1.3052.18.2.12.14.8.1.13
bmDischargingCurrentNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for return to normal discharging current event."
::= { bmDischargingCurrentEntry 14 }
--1.3.6.1.4.1.3052.18.2.12.14.8.1.14
bmDischargingCurrentSysrepEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting enable for discharging current telemetry."
::= { bmDischargingCurrentEntry 15 }
--1.3.6.1.4.1.3052.18.2.12.14.8.1.15
bmDischargingCurrentSysrepThreshold OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting threshold for discharging current telemetry. This is
a floating point value."
::= { bmDischargingCurrentEntry 16 }
--1.3.6.1.4.1.3052.18.2.12.14.8.1.16
bmDischargingCurrentSysrepLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting limit for discharging current telemetry."
::= { bmDischargingCurrentEntry 17 }
--1.3.6.1.4.1.3052.18.2.12.14.8.1.17
batteryMonitorChargeLevelTable OBJECT-TYPE
SYNTAX SEQUENCE OF BatteryMonitorConfigChargeLevel
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes battery monitor charge level attributes."
::= { batteryMonitor 9 }
--1.3.6.1.4.1.3052.18.2.12.14.9
bmChargeLevelEntry OBJECT-TYPE
SYNTAX BatteryMonitorConfigChargeLevel
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for battery monitor charge level config table."
INDEX { bmChargeLevelIndex }
::= { batteryMonitorChargeLevelTable 1 }
--1.3.6.1.4.1.3052.18.2.12.14.9.1
bmChargeLevelIndex OBJECT-TYPE
SYNTAX Integer32 (1..9)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which battery monitor in the battery monitor charge level config table."
::= { bmChargeLevelEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.14.9.1.1
bmChargeLevelEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable charge level event."
::= { bmChargeLevelEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.14.9.1.2
bmChargeLevelNormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for return to normal charge level event."
::= { bmChargeLevelEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.14.9.1.3
bmChargeLevelNormalTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for return to normal charge level event."
::= { bmChargeLevelEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.14.9.1.4
bmChargeLevelNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for return to normal charge level event."
::= { bmChargeLevelEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.14.9.1.5
bmChargeLevelLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for low charge level event."
::= { bmChargeLevelEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.14.9.1.6
bmChargeLevelLowTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for low charge level event."
::= { bmChargeLevelEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.14.9.1.7
bmChargeLevelLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for low charge level event."
::= { bmChargeLevelEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.14.9.1.8
bmChargeLevelVLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for very low charge level event."
::= { bmChargeLevelEntry 9 }
--1.3.6.1.4.1.3052.18.2.12.14.9.1.9
bmChargeLevelVLowTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for very low charge level event."
::= { bmChargeLevelEntry 10 }
--1.3.6.1.4.1.3052.18.2.12.14.9.1.10
bmChargeLevelVLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for very low charge level event."
::= { bmChargeLevelEntry 11 }
--1.3.6.1.4.1.3052.18.2.12.14.9.1.11
bmChargeLevelSysrepEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting enable for charge level telemetry."
::= { bmChargeLevelEntry 12 }
--1.3.6.1.4.1.3052.18.2.12.14.9.1.12
batteryMonitorJarHealthTable OBJECT-TYPE
SYNTAX SEQUENCE OF BatteryMonitorConfigJarHealth
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table organizes battery monitor jar health attributes."
::= { batteryMonitor 10 }
--1.3.6.1.4.1.3052.18.2.12.14.10
bmJarHealthEntry OBJECT-TYPE
SYNTAX BatteryMonitorConfigJarHealth
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for battery monitor jar health config table."
INDEX { bmJarHealthIndex }
::= { batteryMonitorJarHealthTable 1 }
--1.3.6.1.4.1.3052.18.2.12.14.10.1
bmJarHealthIndex OBJECT-TYPE
SYNTAX Integer32 (1..9)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which battery monitor in the battery monitor jar health config table."
::= { bmJarHealthEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.14.10.1.1
bmJarHealthEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable jar health event."
::= { bmJarHealthEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.14.10.1.2
bmJarHealthNormalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for return to normal jar health event."
::= { bmJarHealthEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.14.10.1.3
bmJarHealthNormalTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for return to normal jar health event."
::= { bmJarHealthEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.14.10.1.4
bmJarHealthNormalClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for return to normal jar health event."
::= { bmJarHealthEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.14.10.1.5
bmJarHealthLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for low jar health event."
::= { bmJarHealthEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.14.10.1.6
bmJarHealthLowTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for low jar health event."
::= { bmJarHealthEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.14.10.1.7
bmJarHealthLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for low jar health event."
::= { bmJarHealthEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.14.10.1.8
bmJarHealthVLowActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for very low jar health event."
::= { bmJarHealthEntry 9 }
--1.3.6.1.4.1.3052.18.2.12.14.10.1.9
bmJarHealthVLowTrapNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for very low jar health event."
::= { bmJarHealthEntry 10 }
--1.3.6.1.4.1.3052.18.2.12.14.10.1.10
bmJarHealthVLowClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for very low jar health event."
::= { bmJarHealthEntry 11 }
--1.3.6.1.4.1.3052.18.2.12.14.10.1.11
bmJarHealthSysrepEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System reporting enable for jar health telemetry."
::= { bmJarHealthEntry 12 }
--1.3.6.1.4.1.3052.18.2.12.14.10.1.12
--***************************************************************************************
--Location Event Section 2.14.15
--***************************************************************************************
evLocationEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable location event. This event is triggered after the unit boots
and gets a valid location fix from the GPS, or a timeout expires."
::= { evLocation 1 }
--1.3.6.1.4.1.3052.18.2.12.15.1
evLocationTimeout OBJECT-TYPE
SYNTAX Integer32 (5..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"How long the unit waits for valid location fix before giving up and
generating location event anyhow."
::= { evLocation 2 }
--1.3.6.1.4.1.3052.18.2.12.15.2
evLocationActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for location event."
::= { evLocation 3 }
--1.3.6.1.4.1.3052.18.2.12.15.3
evLocationMsgSuccess OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Event message string that is used when location is successfully detected."
::= { evLocation 4 }
--1.3.6.1.4.1.3052.18.2.12.15.4
evLocationMsgFail OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Event message string that is used when location is cannot be detected."
::= { evLocation 5 }
--1.3.6.1.4.1.3052.18.2.12.15.5
evLocationIncludeLocation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable appending the location information to the event message."
::= { evLocation 6 }
--1.3.6.1.4.1.3052.18.2.12.15.6
evLocationTrapnum OBJECT-TYPE
SYNTAX Integer32 (541..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for the location event."
::= { evLocation 7 }
--1.3.6.1.4.1.3052.18.2.12.15.7
evLocationClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class for the location event."
::= { evLocation 8 }
--1.3.6.1.4.1.3052.18.2.12.15.8
--***************************************************************************************
--Reset Event Section 2.12.16
--***************************************************************************************
evResetEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable reset event. This event is triggered when the unit
finishes booting."
::= { evReset 1 }
--1.3.6.1.4.1.3052.18.2.12.16.1
evResetDelay OBJECT-TYPE
SYNTAX Integer32 (0..3600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of seconds to wait after unit finishes booting before triggering
the reset event."
::= { evReset 2 }
--1.3.6.1.4.1.3052.18.2.12.16.2
evResetActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for reset event."
::= { evReset 3 }
--1.3.6.1.4.1.3052.18.2.12.16.3
evResetMessage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Message for reset event."
::= { evReset 4 }
--1.3.6.1.4.1.3052.18.2.12.16.4
evResetTrapnum OBJECT-TYPE
SYNTAX Integer32 (543..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for reset event."
::= { evReset 5 }
--1.3.6.1.4.1.3052.18.2.12.16.5
evResetClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class (severity) for reset event."
::= { evReset 6 }
--1.3.6.1.4.1.3052.18.2.12.16.6
--***************************************************************************************
--Sleep Event Section 2.12.17
--***************************************************************************************
evSleepEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable sleep event. This event is triggered when the unit is imminently
going to sleep."
::= { evSleep 1 }
--1.3.6.1.4.1.3052.18.2.12.17.1
evSleepActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for sleep event."
::= { evSleep 3 }
--1.3.6.1.4.1.3052.18.2.12.17.3
evSleepMessage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Message for sleep event."
::= { evSleep 4 }
--1.3.6.1.4.1.3052.18.2.12.17.4
evSleepTrapnum OBJECT-TYPE
SYNTAX Integer32 (542..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for sleep event."
::= { evSleep 5 }
--1.3.6.1.4.1.3052.18.2.12.17.5
evSleepClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class (severity) for sleep event."
::= { evSleep 6 }
--1.3.6.1.4.1.3052.18.2.12.17.6
--***************************************************************************************
--Global Event Section 2.12.18
--***************************************************************************************
evGlobalActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Global event actions."
::= { evGlobal 2 }
--1.3.6.1.4.1.3052.18.2.12.18.2
evGlobalTrapnum OBJECT-TYPE
SYNTAX Integer32 (0..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Global trap number."
::= { evGlobal 3 }
--1.3.6.1.4.1.3052.18.2.12.18.3
--***************************************************************************************
--Access Control Device Management Section 2.12.21
--***************************************************************************************
acActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for the access control event."
::= { accessControl 2 }
--1.3.6.1.4.1.3052.18.2.12.21.2
acTrapnum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for the access control event."
::= { accessControl 3 }
--1.3.6.1.4.1.3052.18.2.12.21.3
acClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class (severity) for the access control event."
::= { accessControl 4 }
--1.3.6.1.4.1.3052.18.2.12.21.4
accessControlDeviceTable OBJECT-TYPE
SYNTAX SEQUENCE OF AccessControlDevice
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of access control devices for Access Control Device Management."
::= { accessControl 10 }
--1.3.6.1.4.1.3052.18.2.12.21.10
accessControlDeviceEntry OBJECT-TYPE
SYNTAX AccessControlDevice
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of access control devices for Access Control Device Management."
INDEX { acdIndex }
::= { accessControlDeviceTable 1 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1
acdIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of access control devices for Access Control Device Management."
::= { accessControlDeviceEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.1
acdEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable management for this access control device."
::= { accessControlDeviceEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.2
acdName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the access control device for informational purpose only."
::= { accessControlDeviceEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.3
acdReader OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The kind of access control device."
::= { accessControlDeviceEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.4
acdWiegandES OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Index of the Wiegand interface hardware instance allocated as the access control device."
::= { accessControlDeviceEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.6
acdRelayType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Type of relay which activates the door strike."
::= { accessControlDeviceEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.7
acdRelayES OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Which relay EventSensor is connected to the door strike."
::= { accessControlDeviceEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.8
acdRelayPoint OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Which relay on the relay EventSensor is connected to the door strike."
::= { accessControlDeviceEntry 9 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.9
acdOpenTime OBJECT-TYPE
SYNTAX Integer32 (1..25)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { accessControlDeviceEntry 10 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.10
acdUserGroup OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User group to which this access control device applies."
::= { accessControlDeviceEntry 11 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.11
accessControlUserTable OBJECT-TYPE
SYNTAX SEQUENCE OF AccessControlUser
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of access control users for Access Control Device Management."
::= { accessControl 11 }
--1.3.6.1.4.1.3052.18.2.12.21.11
accessControlUserEntry OBJECT-TYPE
SYNTAX AccessControlUser
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of access control users for Access Control Device Management."
INDEX { acuIndexUserGroup, acuIndexUser }
::= { accessControlUserTable 1 }
--1.3.6.1.4.1.3052.18.2.12.21.11.1
acuIndexUserGroup OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of access control devices for Access Control Device Management
which corresponds to the user group containing the user."
::= { accessControlUserEntry 1 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.1
acuIndexUser OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of access control devices for Access Control Device Management
which corresponds to the user within the user group."
::= { accessControlUserEntry 2 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.2
acuEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable this access control user."
::= { accessControlUserEntry 3 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.3
acuName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name for this access control user."
::= { accessControlUserEntry 4 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.4
acuSn OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Serial number of the card associated with the user."
::= { accessControlUserEntry 5 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.5
acuSunBegin OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time of day (HH:MM) on Sundays when this user should be granted access."
::= { accessControlUserEntry 6 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.6
acuSunEnd OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time of day (HH:MM) on Sundays when this user should be forbidden access."
::= { accessControlUserEntry 7 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.7
acuMonBegin OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time of day (HH:MM) on Mondays when this user should be granted access."
::= { accessControlUserEntry 8 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.8
acuMonEnd OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time of day (HH:MM) on Mondays when this user should be forbidden access."
::= { accessControlUserEntry 9 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.9
acuTueBegin OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time of day (HH:MM) on Tuesdays when this user should be granted access."
::= { accessControlUserEntry 10 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.10
acuTueEnd OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time of day (HH:MM) on Tuesdays when this user should be forbidden access."
::= { accessControlUserEntry 11 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.11
acuWedBegin OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time of day (HH:MM) on Wednesdays when this user should be granted access."
::= { accessControlUserEntry 12 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.12
acuWedEnd OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time of day (HH:MM) on Wednesdays when this user should be forbidden access."
::= { accessControlUserEntry 13 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.13
acuThuBegin OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time of day (HH:MM) on Thursdays when this user should be granted access."
::= { accessControlUserEntry 14 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.14
acuThuEnd OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time of day (HH:MM) on Thursdays when this user should be forbidden access."
::= { accessControlUserEntry 15 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.15
acuFriBegin OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time of day (HH:MM) on Fridays when this user should be granted access."
::= { accessControlUserEntry 16 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.16
acuFriEnd OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time of day (HH:MM) on Fridays when this user should be forbidden access."
::= { accessControlUserEntry 17 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.17
acuSatBegin OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time of day (HH:MM) on Saturdays when this user should be granted access."
::= { accessControlUserEntry 18 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.18
acuSatEnd OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time of day (HH:MM) on Saturdays when this user should be forbidden access."
::= { accessControlUserEntry 19 }
--1.3.6.1.4.1.3052.18.2.12.21.10.1.19
--***************************************************************************************
--Action Section 2.14
--***************************************************************************************
actionSchedEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable action schedule"
::= { actionSched 1 }
--1.3.6.1.4.1.3052.18.2.14.3.1
actionSchedBegin OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"action schedule begin time (HH:MM)"
::= { actionSched 2 }
--1.3.6.1.4.1.3052.18.2.14.3.2
actionSchedEnd OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"action schedule end time (HH:MM)"
::= { actionSched 3 }
--1.3.6.1.4.1.3052.18.2.14.3.3
actionSchedWeekdaysOnly OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF whether the action schedule applies to weekdays only
(ON) or all days (OFF)"
::= { actionSched 4 }
--1.3.6.1.4.1.3052.18.2.14.3.4
actionAsentriaRequireAck OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF Asentria action requires an ack from the receiver"
::= { actionAsentria 1 }
--1.3.6.1.4.1.3052.18.2.14.4.1
actionAsentriaVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"version 1.0 or 1.1"
::= { actionAsentria 2 }
--1.3.6.1.4.1.3052.18.2.14.4.2
actionAsentriaTCPPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TCP port used for TCP-based Asentria alarms"
::= { actionAsentria 3 }
--1.3.6.1.4.1.3052.18.2.14.4.3
actionHostTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActionHostConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of network hosts to use for network-based actions"
::= { action 6 }
--1.3.6.1.4.1.3052.18.2.14.6
actionHostEntry OBJECT-TYPE
SYNTAX ActionHostConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of network hosts to use for network-based
actions"
INDEX { actionHostIndex }
::= { actionHostTable 1 }
--1.3.6.1.4.1.3052.18.2.14.6.1
actionHostIndex OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of network hosts to use for network-based
actions"
::= { actionHostEntry 1 }
--1.3.6.1.4.1.3052.18.2.14.6.1.1
actionHost OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hostname/IP address used as destination for network-based
action (e.g., trap)"
::= { actionHostEntry 2 }
--1.3.6.1.4.1.3052.18.2.14.6.1.2
actionEmailTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActionEmailConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of email addresses to use for email actions"
::= { action 7 }
--1.3.6.1.4.1.3052.18.2.14.7
actionEmailEntry OBJECT-TYPE
SYNTAX ActionEmailConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of email addresses to use for email actions"
INDEX { actionEmailIndex }
::= { actionEmailTable 1 }
--1.3.6.1.4.1.3052.18.2.14.7.1
actionEmailIndex OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of email addresses to use for email actions"
::= { actionEmailEntry 1 }
--1.3.6.1.4.1.3052.18.2.14.7.1.1
actionEmail OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"email address"
::= { actionEmailEntry 2 }
--1.3.6.1.4.1.3052.18.2.14.7.1.2
actionParseError OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When a user attempts to configure an invalid action setting/
object, this object says why it was invalid."
::= { action 8 }
--1.3.6.1.4.1.3052.18.2.14.8
--***************************************************************************************
--System Section 2.16
--***************************************************************************************
sysTimeAutoDST OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF automatically adjust for Daylight Savings Time"
::= { sysTime 1 }
--1.3.6.1.4.1.3052.18.2.16.1.1
sysTimeGMTOffset OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Absolute value of offset (hours) from GMT of the timezone"
::= { sysTime 2 }
--1.3.6.1.4.1.3052.18.2.16.1.2
sysTimeGMTDirection OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Direction (AHEAD/BEHIND) of timezone relative to GMT"
::= { sysTime 3 }
--1.3.6.1.4.1.3052.18.2.16.1.3
sysTimeNetEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Network time mode"
::= { sysTimeNet 1 }
--1.3.6.1.4.1.3052.18.2.16.1.4.1
sysTimeNetHostTable OBJECT-TYPE
SYNTAX SEQUENCE OF NetworkTimeHostConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of hosts to use for network time services"
::= { sysTimeNet 2 }
--1.3.6.1.4.1.3052.18.2.16.1.4.2
sysTimeNetHostEntry OBJECT-TYPE
SYNTAX NetworkTimeHostConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of hosts to use for network time services"
INDEX { sysTimeNetHostIndex }
::= { sysTimeNetHostTable 1 }
--1.3.6.1.4.1.3052.18.2.16.1.4.2.1
sysTimeNetHostIndex OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of hosts to use for network time services"
::= { sysTimeNetHostEntry 1 }
--1.3.6.1.4.1.3052.18.2.16.1.4.2.1.1
sysTimeNetHost OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"host to use for network time services"
::= { sysTimeNetHostEntry 2 }
--1.3.6.1.4.1.3052.18.2.16.1.4.2.1.2
sysPTTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Timeout (minutes) of inactivity after which a pass-through
session is terminated (0 means it never terminates)"
::= { sysPT 1 }
--1.3.6.1.4.1.3052.18.2.16.2.1
sysPTEndPause OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"number of 16ths of a second between escape characters
received on pass-through origin IO handle that are reuired
for the escape characters to register as pass-through escape
characters in the pass-through escape sequence. Set to 0 to
make the escape character register as part of the pass-
through escape sequence without requiring a pause."
::= { sysPT 2 }
--1.3.6.1.4.1.3052.18.2.16.2.2
sysPTJoinable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable joinable pass-through sessions."
::= { sysPT 3 }
--1.3.6.1.4.1.3052.18.2.16.2.3
sysMTU OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum transfer unit for ethernet interfaces"
::= { sys 3 }
--1.3.6.1.4.1.3052.18.2.16.3
sysAnswerString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"String displayed upon login"
::= { sys 4 }
--1.3.6.1.4.1.3052.18.2.16.4
sysEventFileID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ID string for events file"
::= { sys 6 }
--1.3.6.1.4.1.3052.18.2.16.6
sysEscapeCharacter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Decimal ASCII code of the system escape character"
::= { sys 7 }
--1.3.6.1.4.1.3052.18.2.16.7
sysTimeStampTimeFormat OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Format of time stamp: HH:MM,HH:MM:SS,BLANK"
::= { sysTimeStamp 1 }
--1.3.6.1.4.1.3052.18.2.16.8.1
sysTimeStampDateFormat OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Format of date stamp: MM/DD,MM/DD/YY,MM/DD/YYYY,BLANK"
::= { sysTimeStamp 2 }
--1.3.6.1.4.1.3052.18.2.16.8.2
sysTimeStampSpaceAfter OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF Inlude a space after timestamp"
::= { sysTimeStamp 3 }
--1.3.6.1.4.1.3052.18.2.16.8.3
sysLogMode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Syslog mode: disabled, emit UDP (REMOTE), save in a
rotating file set (FILE), or emit on a listening socket
(SERVER)"
::= { sysLog 1 }
--1.3.6.1.4.1.3052.18.2.16.9.1
sysLoghost OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Syslog host: destination machine when syslog mode is REMOTE"
::= { sysLog 2 }
--1.3.6.1.4.1.3052.18.2.16.9.2
sysLogFilter OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"String describing what functions place data in the syslog"
::= { sysLog 3 }
--1.3.6.1.4.1.3052.18.2.16.9.3
sysLogFileSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Size (in KB) of syslog files (when syslog mode is SERVER or
FILE)"
::= { sysLog 4 }
--1.3.6.1.4.1.3052.18.2.16.9.4
sysLogFileCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of files in syslog file set (when syslog mode is
SERVER or FILE)"
::= { sysLog 5 }
--1.3.6.1.4.1.3052.18.2.16.9.5
sysLogListenPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TCP port on which the unit listens for a connection on
which syslog data is dumped (when syslog mode is SERVER)"
::= { sysLog 6 }
--1.3.6.1.4.1.3052.18.2.16.9.6
sysCRDBCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Capacity of Call Record Database (in KB)"
::= { sysCRDB 1 }
--1.3.6.1.4.1.3052.18.2.16.10.1
sysCRDBPercentFull OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percent of the CRDB used"
::= { sysCRDB 2 }
--1.3.6.1.4.1.3052.18.2.16.10.2
sysCRDBFileIDTable OBJECT-TYPE
SYNTAX SEQUENCE OF CRDBFileIDConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of CRDB file IDs"
::= { sysCRDB 3 }
--1.3.6.1.4.1.3052.18.2.16.10.3
sysCRDBFileIDEntry OBJECT-TYPE
SYNTAX CRDBFileIDConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of CRDB file IDs"
INDEX { sysCRDBFileIDIndex }
::= { sysCRDBFileIDTable 1 }
--1.3.6.1.4.1.3052.18.2.16.10.3.1
sysCRDBFileIDIndex OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of CRDB file IDs"
::= { sysCRDBFileIDEntry 1 }
--1.3.6.1.4.1.3052.18.2.16.10.3.1.1
sysCRDBFileID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ID of CRDB file for this port-associated file x"
::= { sysCRDBFileIDEntry 2 }
--1.3.6.1.4.1.3052.18.2.16.10.3.1.2
sysCRDBFileEnforceMinTable OBJECT-TYPE
SYNTAX SEQUENCE OF CRDBFileEnforceMinConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of CRDB file minimum size enforcement settings"
::= { sysCRDB 4 }
--1.3.6.1.4.1.3052.18.2.16.10.4
sysCRDBFileEnforceMinEntry OBJECT-TYPE
SYNTAX CRDBFileEnforceMinConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of CRDB file minimum size enforcement
settings"
INDEX { sysCRDBFileEnforceMinIndex }
::= { sysCRDBFileEnforceMinTable 1 }
--1.3.6.1.4.1.3052.18.2.16.10.4.1
sysCRDBFileEnforceMinIndex OBJECT-TYPE
SYNTAX Integer32 (1..24)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of CRDB file minimum size enforcement
settings"
::= { sysCRDBFileEnforceMinEntry 1 }
--1.3.6.1.4.1.3052.18.2.16.10.4.1.1
sysCRDBFileEnforceMin OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF: enforce minimum size for this CRDB file x"
::= { sysCRDBFileEnforceMinEntry 2 }
--1.3.6.1.4.1.3052.18.2.16.10.4.1.2
sysCharMask OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Character mask used for ignoring certain characters on
serial ports when assembling data records (when port mode is
ASCII)"
::= { sys 11 }
--1.3.6.1.4.1.3052.18.2.16.11
sysPrompt OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Prompt to use in a commnand session"
::= { sys 12 }
--1.3.6.1.4.1.3052.18.2.16.12
sysBootStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"String describing the boot status of the unit (Booted OK/
still booting"
::= { sys 13 }
--1.3.6.1.4.1.3052.18.2.16.13
--***************************************************************************************
--Sys Location Section 2.16.14
--***************************************************************************************
sysLocLatitude OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Latitude portion of geographic coordinates as string"
::= { sysLoc 1 }
--1.3.6.1.4.1.3052.18.2.16.14.1
sysLocLongitude OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Longitude portion of geographic coordinates as string"
::= { sysLoc 2 }
--1.3.6.1.4.1.3052.18.2.16.14.2
sysLocXOffset OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"X-offset portion of geographic coordinates as string"
::= { sysLoc 3 }
--1.3.6.1.4.1.3052.18.2.16.14.3
sysLocYOffset OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Y offset portion of geographic coordinates as string"
::= { sysLoc 4 }
--1.3.6.1.4.1.3052.18.2.16.14.4
sysLocAngle OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Angle portion of geographic coordinates as string"
::= { sysLoc 5 }
--1.3.6.1.4.1.3052.18.2.16.14.5
sysLocAltitude OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Altitude as string"
::= { sysLoc 6 }
--1.3.6.1.4.1.3052.18.2.16.14.6
--***************************************************************************************
--Sleep Mode Section 2.16.16
--***************************************************************************************
sysSleepEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/disables sleep mode. The unit will go into sleep mode only
if this is set to ON."
::= { sysSleep 1 }
--1.3.6.1.4.1.3052.18.2.16.16.1
sysSleepForceSleep OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Write any value to this object to put the unit into sleep mode immediately
(provided sleep mode is enabled)"
::= { sysSleepSleep 1 }
--1.3.6.1.4.1.3052.18.2.16.16.2.1
sysSleepSleepTimer OBJECT-TYPE
SYNTAX Integer32 (10..240)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"How long, in minutes, before the unit will go into sleep mode, measured from
the time it is fully started up, or from the time generator/shore power is lost.
A command could cause the unit to sleep sooner."
::= { sysSleepSleep 2 }
--1.3.6.1.4.1.3052.18.2.16.16.2.2
sysSleepWakeTimerNormal OBJECT-TYPE
SYNTAX Integer32 (1..10800)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"How long, in minutes, the unit will sleep once it goes into sleep mode, unless
something else, such as generator/shore power restoration or movement, causes
wake-up. This timer is used if the unit is not in motion when it goes to sleep."
::= { sysSleepWake 1 }
--1.3.6.1.4.1.3052.18.2.16.16.3.1
sysSleepWakeTimerMotion OBJECT-TYPE
SYNTAX Integer32 (1..10800)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"How long, in minutes, the unit will sleep once it goes into sleep mode, unless
something else, such as generator/shore power restoration, causes wake-up.
This timer is used if the unit goes to sleep while it is in motion, as determined
by the GPS receiver."
::= { sysSleepWake 2 }
--1.3.6.1.4.1.3052.18.2.16.16.3.2
sysSleepWakeMotionEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/disables waking on detected motion."
::= { sysSleepWake 3 }
--1.3.6.1.4.1.3052.18.2.16.16.3.3
sysSleepWakeScheduledEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enabled/disables waking at a specified time of day."
::= { sysSleepWake 4 }
--1.3.6.1.4.1.3052.18.2.16.16.3.4
sysSleepWakeScheduledTimeOfDay OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies what time of day to wake up. Value is in HH:MM format."
::= { sysSleepWake 5 }
--1.3.6.1.4.1.3052.18.2.16.16.3.5
sysSleepPowerDetectCCEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/disables detection of generator/shore power via contact closure 1."
::= { sysSleepPowerDetectCC 1 }
--1.3.6.1.4.1.3052.18.2.16.16.4.1
sysSleepPowerDetectCCPowerOnState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the state (open or closed) that represents generator/shore power being
present."
::= { sysSleepPowerDetectCC 2 }
--1.3.6.1.4.1.3052.18.2.16.16.4.2
sysSleepPowerDetectCCThreshold OBJECT-TYPE
SYNTAX Integer32 (0..99)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the time period, in seconds, for how long the CC must be in a given state
for generator/shore power to be considered present or not."
::= { sysSleepPowerDetectCC 3 }
--1.3.6.1.4.1.3052.18.2.16.16.4.3
--***************************************************************************************
--Sys File Transfer Section 2.16.17
--***************************************************************************************
sysFileTransferStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Start/cancel file transfer, or check transfer status. To start, set this object
to 'start'. To cancel, set this object to 'cancel'. To check status, get the
object"
::= { sysFileTransfer 1 }
--1.3.6.1.4.1.3052.18.2.16.17.1
sysFileTransferURL OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"URL (describing protocol, host, directory, and file) on which file transfer
function operates."
::= { sysFileTransfer 2 }
--1.3.6.1.4.1.3052.18.2.16.17.2
sysFileTransferUsername OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Username for user account at the resource specified by sysFileTransferURL."
::= { sysFileTransfer 3 }
--1.3.6.1.4.1.3052.18.2.16.17.3
sysFileTransferPassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Password for user account at the resource specified by sysFileTransferURL."
::= { sysFileTransfer 4 }
--1.3.6.1.4.1.3052.18.2.16.17.4
--***************************************************************************************
--Sys Update Section 2.16.18
--***************************************************************************************
sysUpdateStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Check time/result of last update attempt."
::= { sysUpdate 1 }
--1.3.6.1.4.1.3052.18.2.16.18.1
--***************************************************************************************
--Audit Log Section 2.17
--***************************************************************************************
auditLogEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable audit log"
::= { auditLog 1 }
--1.3.6.1.4.1.3052.18.2.17.1
auditLogStoreResets OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF audit log stores when the unit resets"
::= { auditLog 2 }
--1.3.6.1.4.1.3052.18.2.17.2
auditLogStoreCommands OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF audit log stores commands entered in a command
session"
::= { auditLog 3 }
--1.3.6.1.4.1.3052.18.2.17.3
auditLogStoreOutputs OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF audit log stores output (relay output and power output)
activity"
::= { auditLog 4 }
--1.3.6.1.4.1.3052.18.2.17.4
auditLogStoreAlarmActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF audit log stores action delivery activity"
::= { auditLog 5 }
--1.3.6.1.4.1.3052.18.2.17.5
auditLogStorePwdFailures OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF audit log stores when user was denied login"
::= { auditLog 6 }
--1.3.6.1.4.1.3052.18.2.17.6
auditLogStoreLogins OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF audit log stores when a user was allowed login"
::= { auditLog 7 }
--1.3.6.1.4.1.3052.18.2.17.7
auditLogStoreSHSK OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF audit log stores serial handshaking status
(regardless of serial handshaking event)"
::= { auditLog 8 }
--1.3.6.1.4.1.3052.18.2.17.8
auditLogStorePassthrough OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF audit log stores pass-through activity"
::= { auditLog 9 }
--1.3.6.1.4.1.3052.18.2.17.9
auditLogStoreInactivity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF audit log stores when sessions expire due to
inactivity"
::= { auditLog 10 }
--1.3.6.1.4.1.3052.18.2.17.10
auditLogStorePolling OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF audit log stores CRDB polling activity"
::= { auditLog 11 }
--1.3.6.1.4.1.3052.18.2.17.11
auditLogMaxSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum size (in KB) of audit log"
::= { auditLog 12 }
--1.3.6.1.4.1.3052.18.2.17.12
auditLogSoreSleepActivity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF audit log stores sleep activity"
::= { auditLog 13 }
--1.3.6.1.4.1.3052.18.2.17.13
--***************************************************************************************
--Scripting Section 2.17
--***************************************************************************************
scrGlobalEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable scripting"
::= { scripting 1 }
--1.3.6.1.4.1.3052.18.2.18.1
scrDTRCtrlPortEnableTable OBJECT-TYPE
SYNTAX SEQUENCE OF ScriptingDTRCtrlPortEnableConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of DTR control port enables"
::= { scripting 2 }
--1.3.6.1.4.1.3052.18.2.18.2
scrDTRCtrlPortEnableEntry OBJECT-TYPE
SYNTAX ScriptingDTRCtrlPortEnableConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of DTR control port enables"
INDEX { scrDTRCtrlPortEnableIndex }
::= { scrDTRCtrlPortEnableTable 1 }
--1.3.6.1.4.1.3052.18.2.18.2.1
scrDTRCtrlPortEnableIndex OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of DTR control port enables"
::= { scrDTRCtrlPortEnableEntry 1 }
--1.3.6.1.4.1.3052.18.2.18.2.1.1
scrDTRCtrlPortEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable DTR control of scripting for this port"
::= { scrDTRCtrlPortEnableEntry 2 }
--1.3.6.1.4.1.3052.18.2.18.2.1.2
scrTable OBJECT-TYPE
SYNTAX SEQUENCE OF ScriptingConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of scripts"
::= { scripting 3 }
--1.3.6.1.4.1.3052.18.2.18.3
scrEntry OBJECT-TYPE
SYNTAX ScriptingConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of scripts"
INDEX { scrIndex }
::= { scrTable 1 }
--1.3.6.1.4.1.3052.18.2.18.3.1
scrIndex OBJECT-TYPE
SYNTAX Integer32 (1..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of scripts"
::= { scrEntry 1 }
--1.3.6.1.4.1.3052.18.2.18.3.1.1
scrEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF enable this script"
::= { scrEntry 2 }
--1.3.6.1.4.1.3052.18.2.18.3.1.2
scrName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of this script"
::= { scrEntry 3 }
--1.3.6.1.4.1.3052.18.2.18.3.1.3
scrFilename OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Filename for this script"
::= { scrEntry 4 }
--1.3.6.1.4.1.3052.18.2.18.3.1.4
scrRunAlways OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF: this script always runs"
::= { scrEntry 5 }
--1.3.6.1.4.1.3052.18.2.18.3.1.5
scrRunAtStartup OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF: this script runs at startup"
::= { scrEntry 6 }
--1.3.6.1.4.1.3052.18.2.18.3.1.6
scrRunScheduled OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ON/OFF: this script runs at a certain time of day"
::= { scrEntry 7 }
--1.3.6.1.4.1.3052.18.2.18.3.1.7
scrScheduleTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time of day (HH:MM) this script is scheduled to run"
::= { scrEntry 8 }
--1.3.6.1.4.1.3052.18.2.18.3.1.8
scrArguments OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Arguments for this script"
::= { scrEntry 9 }
--1.3.6.1.4.1.3052.18.2.18.3.1.9
scrRepeatInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"How often this script runs (minutes)"
::= { scrEntry 10 }
--1.3.6.1.4.1.3052.18.2.18.3.1.10
scrVolatileStringTable OBJECT-TYPE
SYNTAX SEQUENCE OF ScriptingVolatileString
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of volatile string settings for use in
scripts."
::= { scripting 4 }
--1.3.6.1.4.1.3052.18.2.18.4
scrVolatileStringEntry OBJECT-TYPE
SYNTAX ScriptingVolatileString
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of volatile script string
settings"
INDEX { scrVolatileStringIndex }
::= { scrVolatileStringTable 1 }
--1.3.6.1.4.1.3052.18.2.18.4.1
scrVolatileStringIndex OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of volatile script string
settings"
::= { scrVolatileStringEntry 1 }
--1.3.6.1.4.1.3052.18.2.18.4.1.1
scrVolatileString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Volatile string for use in scripts. Use this
object to cache frequently-changing string values
or string values that do not need to persist
through reset. This object corresponds to the
scripting.vstring[] setting key branch; use those
keys in scripts and you can view or change their
values with this object."
::= { scrVolatileStringEntry 2 }
--1.3.6.1.4.1.3052.18.2.18.4.1.2
scrVolatileIntTable OBJECT-TYPE
SYNTAX SEQUENCE OF ScriptingVolatileInt
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of volatile integer settings for use in
scripts."
::= { scripting 5 }
--1.3.6.1.4.1.3052.18.2.18.5
scrVolatileIntEntry OBJECT-TYPE
SYNTAX ScriptingVolatileInt
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of volatile script integer
settings"
INDEX { scrVolatileIntIndex }
::= { scrVolatileIntTable 1 }
--1.3.6.1.4.1.3052.18.2.18.5.1
scrVolatileIntIndex OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of volatile script integer
settings"
::= { scrVolatileIntEntry 1 }
--1.3.6.1.4.1.3052.18.2.18.5.1.1
scrVolatileInt OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Volatile integer for use in scripts. Use this
object to cache frequently-changing integer values
or integer values that do not need to persist
through reset. This object corresponds to the
scripting.vint[] setting key branch; use those
keys in scripts and you can view or change their
values with this object."
::= { scrVolatileIntEntry 2 }
--1.3.6.1.4.1.3052.18.2.18.5.1.2
scrNonVolatileStringTable OBJECT-TYPE
SYNTAX SEQUENCE OF ScriptingNonVolatileString
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of non-volatile string settings for use in
scripts."
::= { scripting 6 }
--1.3.6.1.4.1.3052.18.2.18.6
scrNonVolatileStringEntry OBJECT-TYPE
SYNTAX ScriptingNonVolatileString
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of non-volatile script string
settings"
INDEX { scrNonVolatileStringIndex }
::= { scrNonVolatileStringTable 1 }
--1.3.6.1.4.1.3052.18.2.18.6.1
scrNonVolatileStringIndex OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of non-volatile script string
settings"
::= { scrNonVolatileStringEntry 1 }
--1.3.6.1.4.1.3052.18.2.18.6.1.1
scrNonVolatileString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Non-volatile string for use in scripts. Use this
object to store values that need to persist
through reset. This object corresponds to the
scripting.nvstring[] setting key branch; use those
keys in scripts and you can view or change their
values with this object. Note: to store frequently-
changing integers, use the scrVolatileString object,
otherwise your scripts may cause unnecessary wear of
the non-volatile storage medium on the unit."
::= { scrNonVolatileStringEntry 2 }
--1.3.6.1.4.1.3052.18.2.18.6.1.2
scrNonVolatileIntTable OBJECT-TYPE
SYNTAX SEQUENCE OF ScriptingNonVolatileInt
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of non-volatile integer settings for use in
scripts."
::= { scripting 7 }
--1.3.6.1.4.1.3052.18.2.18.7
scrNonVolatileIntEntry OBJECT-TYPE
SYNTAX ScriptingNonVolatileInt
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of non-volatile script integer
settings"
INDEX { scrNonVolatileIntIndex }
::= { scrNonVolatileIntTable 1 }
--1.3.6.1.4.1.3052.18.2.18.7.1
scrNonVolatileIntIndex OBJECT-TYPE
SYNTAX Integer32 (1..50)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of non-volatile script integer
settings"
::= { scrNonVolatileIntEntry 1 }
--1.3.6.1.4.1.3052.18.2.18.7.1.1
scrNonVolatileInt OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Non-volatile integer for use in scripts. Use this
object to store integer values that need to persist
through reset. This object corresponds to the
scripting.nvint[] setting key branch; use those
keys in scripts and you can view or change their
values with this object. Note: to store frequently-
changing integers, use the scrVolatileInt object,
otherwise your scripts may cause unnecessary wear of
the non-volatile storage medium on the unit."
::= { scrNonVolatileIntEntry 2 }
--1.3.6.1.4.1.3052.18.2.18.7.1.2
--***************************************************************************************
--Generator Section 2.19
--***************************************************************************************
genSetEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable genset functionality; that is, a generator is in use."
::= { genSet 1 }
--1.3.6.1.4.1.3052.18.2.19.1.1
genSetRelayEs OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Which EventSensor has the relay which starts the generator,
for genset relay configuration 1 only. This object maps to the
same setting as genSetRelayTableEs.1."
::= { genSetRelay 1 }
--1.3.6.1.4.1.3052.18.2.19.1.2.1
genSetRelayPoint OBJECT-TYPE
SYNTAX Integer32 (1..13)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Which relay starts the generator, for genset relay configuration
1 only. This object maps to the same setting as genSetRelayTablePoint.1."
::= { genSetRelay 2 }
--1.3.6.1.4.1.3052.18.2.19.1.2.2
genSetRelayRunningstate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Which relay state corresponds with the generator starting/running.
This object maps to the same setting as genSetRelayTableRunningstate.1."
::= { genSetRelay 3 }
--1.3.6.1.4.1.3052.18.2.19.1.2.3
genSetRelayTable OBJECT-TYPE
SYNTAX SEQUENCE OF GenSetRelaySequence
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of relays for genset ignition."
::= { genSetRelay 5 }
--1.3.6.1.4.1.3052.18.2.19.1.2.5
genSetRelayTableEntry OBJECT-TYPE
SYNTAX GenSetRelaySequence
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of relays for genset ignition."
INDEX { genSetRelayTableIndex }
::= { genSetRelayTable 1 }
--1.3.6.1.4.1.3052.18.2.19.1.2.5.1
genSetRelayTableIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of relays for genset ignition."
::= { genSetRelayTableEntry 1 }
--1.3.6.1.4.1.3052.18.2.19.1.2.5.1.1
genSetRelayTableEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable this relay for starting the generator."
::= { genSetRelayTableEntry 2 }
--1.3.6.1.4.1.3052.18.2.19.1.2.5.1.2
genSetRelayTableEs OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Which EventSensor has the relay which starts the generator, for this
genset relay configuration specified by the table index."
::= { genSetRelayTableEntry 3 }
--1.3.6.1.4.1.3052.18.2.19.1.2.5.1.3
genSetRelayTablePoint OBJECT-TYPE
SYNTAX Integer32 (1..13)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Which relay point on the EventSensor used for starting the generator,
for this genset relay configuration specified by the table index."
::= { genSetRelayTableEntry 4 }
--1.3.6.1.4.1.3052.18.2.19.1.2.5.1.4
genSetRelayTableRunningstate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Which relay state corresponds with the generator starting/running,
for this genset relay configuration specified by the table index."
::= { genSetRelayTableEntry 5 }
--1.3.6.1.4.1.3052.18.2.19.1.2.5.1.5
genSetCCEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable generator running detection functionality; that is, the
associated CC is valid for determining if generator is running."
::= { genSetCC 1 }
--1.3.6.1.4.1.3052.18.2.19.1.3.1
genSetCCEs OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Which CC EventSensor has the CC which is connected to the genertor
running detection monitor."
::= { genSetCC 2 }
--1.3.6.1.4.1.3052.18.2.19.1.3.2
genSetCCPoint OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Which CC is connected to the genertor running detection monitor."
::= { genSetCC 3 }
--1.3.6.1.4.1.3052.18.2.19.1.3.3
genSetCCRunningState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Which CC physical state corresponds with the generator running."
::= { genSetCC 4 }
--1.3.6.1.4.1.3052.18.2.19.1.3.4
genSetCCDelay OBJECT-TYPE
SYNTAX Integer32 (0..600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"How long (in seconds) to wait for the generator to indicate
itself as running after engaging the generator-starting mechanism."
::= { genSetCC 5 }
--1.3.6.1.4.1.3052.18.2.19.1.3.5
genRunMode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Generator Exercising function main operating mode; set to INHIBIT
to inhibit exercising the generator."
::= { genRun 1 }
--1.3.6.1.4.1.3052.18.2.19.2.1
genRunSched OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Schedule number(s) which govern(s) when Generator Exercising function
runs."
::= { genRun 2 }
--1.3.6.1.4.1.3052.18.2.19.2.2
genRunDuration OBJECT-TYPE
SYNTAX Integer32 (600..3600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of seconds that generator should run, started when the
generator needs to start by SCHEDULE or by being forced to start."
::= { genRun 3 }
--1.3.6.1.4.1.3052.18.2.19.2.3
genRunForce OBJECT-TYPE
SYNTAX Integer32 (0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Write 1 to this to force the generator exercising to start. Always
reads as 0."
::= { genRun 4 }
--1.3.6.1.4.1.3052.18.2.19.2.4
genRunReqasm OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Require ASM connectivity before starting the generator from a schedule."
::= { genRun 5 }
--1.3.6.1.4.1.3052.18.2.19.2.5
genRunStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of Generator Exercising function."
::= { genRun 6 }
--1.3.6.1.4.1.3052.18.2.19.2.6
genRunNonstartEventEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable generator non-start event."
::= { genRunNonstartEvent 1 }
--1.3.6.1.4.1.3052.18.2.19.2.7.1
genRunNonstartEventActions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actions for generator non-start event."
::= { genRunNonstartEvent 2 }
--1.3.6.1.4.1.3052.18.2.19.2.7.2
genRunNonstartEventTrap OBJECT-TYPE
SYNTAX Integer32 (536..1199)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap number for generator non-start event."
::= { genRunNonstartEvent 3 }
--1.3.6.1.4.1.3052.18.2.19.2.7.3
genRunNonstartEventClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Class (severity) for generator non-start event."
::= { genRunNonstartEvent 4 }
--1.3.6.1.4.1.3052.18.2.19.2.7.4
--***************************************************************************************
--Calendar Section 2.20
--***************************************************************************************
schedTable OBJECT-TYPE
SYNTAX SEQUENCE OF ScheduleConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of schedules"
::= { calendar 1 }
--1.3.6.1.4.1.3052.18.2.20.1
schedEntry OBJECT-TYPE
SYNTAX ScheduleConfig
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for table of schedules."
INDEX { schedIndex }
::= { schedTable 1 }
--1.3.6.1.4.1.3052.18.2.20.1.1
schedIndex OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table of schedules."
::= { schedEntry 1 }
--1.3.6.1.4.1.3052.18.2.20.1.1.1
schedEnable OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable this schedule."
::= { schedEntry 2 }
--1.3.6.1.4.1.3052.18.2.20.1.1.2
schedStart OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is of the form 'mm/dd/yy hh:mm:ss'. This controls on which
date/time the schedule starts."
::= { schedEntry 3 }
--1.3.6.1.4.1.3052.18.2.20.1.1.3
schedRepeatMode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls in which way the schedule should repeat."
::= { schedEntry 4 }
--1.3.6.1.4.1.3052.18.2.20.1.1.4
schedRepeatFreq OBJECT-TYPE
SYNTAX Integer32 (1..400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls how often the schedule should repeat: every nth day, week,
month, or year."
::= { schedEntry 5 }
--1.3.6.1.4.1.3052.18.2.20.1.1.5
schedRepeatEndMode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls how the repeating schedule should end."
::= { schedEntry 6 }
--1.3.6.1.4.1.3052.18.2.20.1.1.6
schedRepeatEndAfter OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of times this schedule should be repeated; relevant when the
repeat end mode is AFTER."
::= { schedEntry 7 }
--1.3.6.1.4.1.3052.18.2.20.1.1.7
schedRepeatEndOn OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Date/time (in the form 'mm/yy/dd hh:mm:ss' or blank string) after
which repeating should end, relevant when repeat end mode is ON DATE."
::= { schedEntry 8 }
--1.3.6.1.4.1.3052.18.2.20.1.1.8
schedRepeatWeeklySun OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Run this schedule on Sunday(s); relevant when repeat mode is weekly."
::= { schedEntry 9 }
--1.3.6.1.4.1.3052.18.2.20.1.1.9
schedRepeatWeeklyMon OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Run this schedule on Monday(s); relevant when repeat mode is weekly."
::= { schedEntry 10 }
--1.3.6.1.4.1.3052.18.2.20.1.1.10
schedRepeatWeeklyTue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Run this schedule on Tuesday(s); relevant when repeat mode is weekly."
::= { schedEntry 11 }
--1.3.6.1.4.1.3052.18.2.20.1.1.11
schedRepeatWeeklyWed OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Run this schedule on Wednesday(s); relevant when repeat mode is weekly."
::= { schedEntry 12 }
--1.3.6.1.4.1.3052.18.2.20.1.1.12
schedRepeatWeeklyThu OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Run this schedule on Thursday(s); relevant when repeat mode is weekly."
::= { schedEntry 13 }
--1.3.6.1.4.1.3052.18.2.20.1.1.13
schedRepeatWeeklyFri OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Run this schedule on Friday(s); relevant when repeat mode is weekly."
::= { schedEntry 14 }
--1.3.6.1.4.1.3052.18.2.20.1.1.14
schedRepeatWeeklySat OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Run this schedule on Saturday(s); relevant when repeat mode is weekly."
::= { schedEntry 15 }
--1.3.6.1.4.1.3052.18.2.20.1.1.15
schedRepeatMonthlyMode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"EACH means the schedule runs on specific dates of the month. ON THE
means the schedule runs on calculated dates of the month according to
which day that month starts."
::= { schedEntry 16 }
--1.3.6.1.4.1.3052.18.2.20.1.1.16
schedRepeatMonthlyDates OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Comma-separated list of dates of a month on which this schedule should
run, relevant when repeat monthly mode is EACH."
::= { schedEntry 17 }
--1.3.6.1.4.1.3052.18.2.20.1.1.17
schedRepeatMonthlyOnThe OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls on which day of the month this schedule should run, relevant
when repeat monthly mode is ON THE."
::= { schedEntry 18 }
--1.3.6.1.4.1.3052.18.2.20.1.1.18
schedRepeatMonthlyOnDay OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls the day of week on which this schedule is run, relevant when
repeat monthly mode is ON THE"
::= { schedEntry 19 }
--1.3.6.1.4.1.3052.18.2.20.1.1.19
schedRepeatYearlyJan OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Run this schedule in January, relevant when repeat mode is YEARLY."
::= { schedEntry 20 }
--1.3.6.1.4.1.3052.18.2.20.1.1.20
schedRepeatYearlyFeb OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Run this schedule in February, relevant when repeat mode is YEARLY."
::= { schedEntry 21 }
--1.3.6.1.4.1.3052.18.2.20.1.1.21
schedRepeatYearlyMar OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Run this schedule in March, relevant when repeat mode is YEARLY."
::= { schedEntry 22 }
--1.3.6.1.4.1.3052.18.2.20.1.1.22
schedRepeatYearlyApr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Run this schedule in April, relevant when repeat mode is YEARLY."
::= { schedEntry 23 }
--1.3.6.1.4.1.3052.18.2.20.1.1.23
schedRepeatYearlyMay OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Run this schedule in May, relevant when repeat mode is YEARLY."
::= { schedEntry 24 }
--1.3.6.1.4.1.3052.18.2.20.1.1.24
schedRepeatYearlyJun OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Run this schedule in June, relevant when repeat mode is YEARLY."
::= { schedEntry 25 }
--1.3.6.1.4.1.3052.18.2.20.1.1.25
schedRepeatYearlyJul OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Run this schedule in July, relevant when repeat mode is YEARLY."
::= { schedEntry 26 }
--1.3.6.1.4.1.3052.18.2.20.1.1.26
schedRepeatYearlyAug OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Run this schedule in August, relevant when repeat mode is YEARLY."
::= { schedEntry 27 }
--1.3.6.1.4.1.3052.18.2.20.1.1.27
schedRepeatYearlySep OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Run this schedule in September, relevant when repeat mode is YEARLY."
::= { schedEntry 28 }
--1.3.6.1.4.1.3052.18.2.20.1.1.28
schedRepeatYearlyOct OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Run this schedule in October, relevant when repeat mode is YEARLY."
::= { schedEntry 29 }
--1.3.6.1.4.1.3052.18.2.20.1.1.29
schedRepeatYearlyNov OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Run this schedule in November, relevant when repeat mode is YEARLY."
::= { schedEntry 30 }
--1.3.6.1.4.1.3052.18.2.20.1.1.30
schedRepeatYearlyDec OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Run this schedule in December, relevant when repeat mode is YEARLY."
::= { schedEntry 31 }
--1.3.6.1.4.1.3052.18.2.20.1.1.31
schedRepeatYearlyOnThe OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls on which day of the month this schedule should run, relevant
when repeat mode is YEARLY."
::= { schedEntry 32 }
--1.3.6.1.4.1.3052.18.2.20.1.1.32
schedRepeatYearlyOnDay OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls the day of week on which this schedule is run, relevant when
repeat mode is YEARLY."
::= { schedEntry 33 }
--1.3.6.1.4.1.3052.18.2.20.1.1.33
schedNextTrigger OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When this schedule will next trigger."
::= { schedEntry 34 }
--1.3.6.1.4.1.3052.18.2.20.1.1.34
--***************************************************************************************
--Product IDs Section 3
--***************************************************************************************
siteName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Site Name string; Max 40 characters."
::= { productIds 1 }
--1.3.6.1.4.1.3052.18.3.1
thisProduct OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a factory configured string for the
product name."
::= { productIds 2 }
--1.3.6.1.4.1.3052.18.3.2
stockTrapString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The message defined for the event that triggers a trap."
::= { productIds 3 }
--1.3.6.1.4.1.3052.18.3.3
trapEventTypeNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user-defined trap variable for the type of
event that happened. Definitions:
4 Scheduled
7 Serial Handshaking Low
8 Serial Handshaking High
10 Contact Closure Active
11 Contact Closure Inactive
12 Temperature High
13 Temperature Very High
14 Temperature Low
15 Temperature Very Low
16 Temperature Return to Normal
17 Humidity High
18 Humidity Very High
19 Humidity Low
20 Humidity Very Low
21 Humidity Return to Normal
26 Analog High
27 Analog Very High
28 Analog Low
29 Analog Very Low
30 Analog Normal
40 EventSensor Unresponsive
41 Custom
42 CPE Down
44 CPE Normal
49 Fuel Sensor Disconnect
50 Fuel Sensor Disconnect Return to Normal
56 Fuel Sensor
57 AC Power Monitor Average Voltage Very Low
58 AC Power Monitor Average Voltage Low
59 AC Power Monitor Average Voltage Return to Normal
60 AC Power Monitor Average Voltage High
61 AC Power Monitor Average Voltage Very High
62 AC Power Monitor Average Current Very Low
63 AC Power Monitor Average Current Low
64 AC Power Monitor Average Current Return to Normal
65 AC Power Monitor Average Current High
66 AC Power Monitor Average Current Very High
67 AC Power Monitor Frequency Very Low
68 AC Power Monitor Frequency Low
69 AC Power Monitor Frequency Return to Normal
70 AC Power Monitor Frequency High
71 AC Power Monitor Frequency Very High
72 AC Power Monitor Total Real Power Very Low
73 AC Power Monitor Total Real Power Low
74 AC Power Monitor Total Real Power Return to Normal
75 AC Power Monitor Total Real Power High
76 AC Power Monitor Total Real Power Very High
77 AC Power Monitor Disconnect
78 AC Power Monitor Disconnect Return to Normal
81 Fuel Sensor Volume Sudden Change
82 Fuel Sensor Volume Slow Change
83 CPE Down Reminder
84 AC Power Monitor Total Power Factor Very Low
85 AC Power Monitor Total Power Factor Low
86 AC Power Monitor Total Power Factor Return to Normal
100 Contact Closure Active Reminder
101 Temperature High Reminder
102 Temperature High Very Reminder
103 Temperature Low Reminder
104 Temperature Very Low Reminder
105 Humidity High Reminder
106 Humidity Very High Reminder
107 Humidity Low Reminder
108 Humidity Very Low Reminder
109 Analog High Reminder
110 Analog Very High Reminder
111 Analog Low Reminder
112 Analog Very Low Reminder
130 Relay Output Active
131 Relay Output Inactive
132 Power Output On
133 Power Output Off
134 Battery Monitor Temperature High
135 Battery Monitor Temperature Return to Normal
136 Battery Monitor Temperature Low
137 Battery Monitor Differential Temperature High
138 Battery Monitor Differential Temperature Return to Normal
139 Battery Monitor Differential Temperature Low
140 Battery Monitor Voltage Very High
141 Battery Monitor Voltage High
142 Battery Monitor Voltage Return to Normal
143 Battery Monitor Voltage Low
144 Battery Monitor Voltage Very Low
145 Battery Monitor Differential Voltage Very High
146 Battery Monitor Differential Voltage High
147 Battery Monitor Differential Voltage Return to Normal
148 Battery Monitor Charge Level Return to Normal
149 Battery Monitor Charge Level Low
150 Battery Monitor Charge Level Very Low
151 Battery Monitor Health Return to Normal
152 Battery Monitor Health Low
153 Battery Monitor Health Very Low
154 Battery Monitor Charge Current Very High
155 Battery Monitor Charge Current High
156 Battery Monitor Charge Current Return to Normal
157 Battery Monitor Discharge Current Very High
158 Battery Monitor Discharge Current High
159 Battery Monitor Discharge Return to Normal
160 Generator Failed to Start
162 Location Fix Failure
163 Location Fix Success
164 Reset
165 Sleep
166 Fuel Sensor Levels Auto Adjust
"
::= { productIds 4 }
--1.3.6.1.4.1.3052.18.3.4
trapEventTypeName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user-defined trap variable for the string
corresponding to the event type."
::= { productIds 5 }
--1.3.6.1.4.1.3052.18.3.5
trapIncludedValue OBJECT-TYPE
SYNTAX Integer32 (-2147483648..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user-defined trap variable for the generic
included value."
::= { productIds 6 }
--1.3.6.1.4.1.3052.18.3.6
trapIncludedString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user-defined trap variable for the generic
included string."
::= { productIds 7 }
--1.3.6.1.4.1.3052.18.3.7
trapTypeString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The cause of the trap, added for DL880 compatibility."
::= { productIds 8 }
--1.3.6.1.4.1.3052.18.3.8
trapEventClassNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user-defined trap variable for the configurable
class number associated with the triggering event."
::= { productIds 9 }
--1.3.6.1.4.1.3052.18.3.9
trapEventClassName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user-defined trap variable for the configurable
class name associated with the class number."
::= { productIds 10 }
--1.3.6.1.4.1.3052.18.3.10
--***************************************************************************************
--Key Interface Section 4
--***************************************************************************************
keyInterface OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents a setting key interface. When
setting this object, the value to set is the 'sk' command
you would enter on the command line (without the 'sk'). To
get the result of the operation, read this object after you
write it.
For example, to configure EventSensor 1 contact closure 34
event actions to be an SNMP InformRequest to host foo, set
this object to:
'event.sensor[1].cc[34].eventactions=inform(foo)'. The SNMP
response is the result of the operation: if setting that key
to that value was a success then the SNMP response will be a
success and the response value will be what you had set. If
you subsequently read this object then you will see a
message 'OK: ...'.
If setting that key to that value failed then the SNMP
response will be a failure (a badValue response). If you
subsequently read this object then the value returned is the
reason that setting that key to that value failed.
For another example, to read user 3's pass-through access
for port 7, set this object to:
'sec.user[3].port[7].ptaccess'. The SNMP response is the
result of the operation: if reading that key is a success
then the SNMP response will be a success and the response
value will be what you had SET (i.e., the opertion of
reading a key, which is just the key itself with no '='
operator, and this is not the key value you want to read).
If you subsequently read this object then the value
returned is the value of the key you want to read.
If reading that key failed (e.g., if the key is invalid)
then the SNMP response to your SNMP set operation (the
value you set being the invalid key to read) will be a
failure (a badValue response). If you subsequently read
this object then the value returned is the reason that
reading that key failed (i.e., 'invalid key')."
::= { s350 4 }
--1.3.6.1.4.1.3052.18.4
--***************************************************************************************
--TABLE DEFINITIONS
--***************************************************************************************
ESPointConfigTemp ::=
SEQUENCE {
espcTempIndexES
Integer32,
espcTempIndexPoint
Integer32,
espcTempEnable
DisplayString,
espcTempScale
DisplayString,
espcTempDeadband
DisplayString,
espcTempVHighTemp
DisplayString,
espcTempVHighActions
DisplayString,
espcTempVHighTrapnum
Integer32,
espcTempVHighClass
DisplayString,
espcTempHighTemp
DisplayString,
espcTempHighActions
DisplayString,
espcTempHighTrapnum
Integer32,
espcTempHighClass
DisplayString,
espcTempNormalActions
DisplayString,
espcTempNormalTrapnum
Integer32,
espcTempNormalClass
DisplayString,
espcTempLowTemp
DisplayString,
espcTempLowActions
DisplayString,
espcTempLowTrapnum
Integer32,
espcTempLowClass
DisplayString,
espcTempVLowTemp
DisplayString,
espcTempVLowActions
DisplayString,
espcTempVLowTrapnum
Integer32,
espcTempVLowClass
DisplayString
}
ESPointConfigCC ::=
SEQUENCE {
espcCCIndexES
Integer32,
espcCCIndexPoint
Integer32,
espcCCEnable
DisplayString,
espcCCName
DisplayString,
espcCCEventState
DisplayString,
espcCCThreshold
Integer32,
espcCCEventActions
DisplayString,
espcCCEventTrapnum
Integer32,
espcCCEventClass
DisplayString,
espcCCNormalActions
DisplayString,
espcCCNormalTrapnum
Integer32,
espcCCNormalClass
DisplayString,
espcCCAlarmAlias
DisplayString,
espcCCNormalAlias
DisplayString,
espcCCNormalThreshold
Integer32,
espcCCOverrideGlobalReminder
DisplayString,
espcCCReminderInterval
Integer32
}
ESPointConfigHumid ::=
SEQUENCE {
espcHumidIndexES
Integer32,
espcHumidIndexPoint
Integer32,
espcHumidEnable
DisplayString,
espcHumidDeadband
Integer32,
espcHumidVHighHumid
Integer32,
espcHumidVHighActions
DisplayString,
espcHumidVHighTrapnum
Integer32,
espcHumidVHighClass
DisplayString,
espcHumidHighHumid
Integer32,
espcHumidHighActions
DisplayString,
espcHumidHighTrapnum
Integer32,
espcHumidHighClass
DisplayString,
espcHumidNormalActions
DisplayString,
espcHumidNormalTrapnum
Integer32,
espcHumidNormalClass
DisplayString,
espcHumidLowHumid
Integer32,
espcHumidLowActions
DisplayString,
espcHumidLowTrapnum
Integer32,
espcHumidLowClass
DisplayString,
espcHumidVLowHumid
Integer32,
espcHumidVLowActions
DisplayString,
espcHumidVLowTrapnum
Integer32,
espcHumidVLowClass
DisplayString
}
ESPointConfigAnalogInput ::=
SEQUENCE {
espcAIIndexES
Integer32,
espcAIIndexPoint
Integer32,
espcAIEnable
DisplayString,
espcAIDeadband
DisplayString,
espcAIVhighValue
DisplayString,
espcAIVhighActions
DisplayString,
espcAIVhighTrapnum
Integer32,
espcAIVhighClass
DisplayString,
espcAIHighValue
DisplayString,
espcAIHighActions
DisplayString,
espcAIHighTrapnum
Integer32,
espcAIHighClass
DisplayString,
espcAINormalActions
DisplayString,
espcAINormalTrapnum
Integer32,
espcAINormalClass
DisplayString,
espcAILowValue
DisplayString,
espcAILowActions
DisplayString,
espcAILowTrapnum
Integer32,
espcAILowClass
DisplayString,
espcAIVlowValue
DisplayString,
espcAIVlowActions
DisplayString,
espcAIVlowTrapnum
Integer32,
espcAIVlowClass
DisplayString,
espcAIConvUnitName
DisplayString,
espcAIConvHighValue
DisplayString,
espcAIConvHighUnit
DisplayString,
espcAIConvLowValue
DisplayString,
espcAIConvLowUnit
DisplayString,
espcAIDisplayFormat
DisplayString
}
ESPointConfigOutput ::=
SEQUENCE {
espcOutputIndexES
Integer32,
espcOutputIndexPoint
Integer32,
espcOutputEnable
DisplayString,
espcOutputActiveState
DisplayString,
espcOutputType
DisplayString,
espcOutputAliasValue
DisplayString,
espcOutputAliasColor
DisplayString,
espcOutputActiveAlias
DisplayString,
espcOutputActiveColor
DisplayString,
espcOutputActiveActions
DisplayString,
espcOutputActiveTrapnum
Integer32,
espcOutputActiveClass
DisplayString,
espcOutputInactiveAlias
DisplayString,
espcOutputInactiveColor
DisplayString,
espcOutputInactiveActions
DisplayString,
espcOutputInactiveTrapnum
Integer32,
espcOutputInactiveClass
DisplayString
}
EventClassConfig ::=
SEQUENCE {
evClassNameIndex
Integer32,
evClassName
DisplayString
}
CPEConfig ::=
SEQUENCE {
cpeIndex
Integer32,
cpeHost
DisplayString,
cpeName
DisplayString,
cpeDescription
DisplayString,
cpeKeepalive
Integer32,
cpeThreshold
Integer32,
cpeEventReminderInterval
Integer32,
cpeKeepaliveTicks
Integer32,
cpePingSize
Integer32,
cpeInfoReset
Integer32,
cpeInfoNumReq
Integer32,
cpeInfoNumGoodResp
Integer32,
cpeInfoNumBadResp
Integer32,
cpeInfoNumLostResp
Integer32,
cpeInfoPercentLoss
DisplayString,
cpeInfoPercentBad
DisplayString
}
ScriptingConfig ::=
SEQUENCE {
scrIndex
Integer32,
scrEnable
DisplayString,
scrName
DisplayString,
scrFilename
DisplayString,
scrRunAlways
DisplayString,
scrRunAtStartup
DisplayString,
scrRunScheduled
DisplayString,
scrScheduleTime
DisplayString,
scrArguments
DisplayString,
scrRepeatInterval
Integer32
}
ScriptingDTRCtrlPortEnableConfig ::=
SEQUENCE {
scrDTRCtrlPortEnableIndex
Integer32,
scrDTRCtrlPortEnable
DisplayString
}
ScriptingVolatileString ::=
SEQUENCE {
scrVolatileStringIndex
Integer32,
scrVolatileString
DisplayString
}
ScriptingVolatileInt ::=
SEQUENCE {
scrVolatileIntIndex
Integer32,
scrVolatileInt
Integer32
}
ScriptingNonVolatileString ::=
SEQUENCE {
scrNonVolatileStringIndex
Integer32,
scrNonVolatileString
DisplayString
}
ScriptingNonVolatileInt ::=
SEQUENCE {
scrNonVolatileIntIndex
Integer32,
scrNonVolatileInt
Integer32
}
GenSetRelaySequence ::=
SEQUENCE {
genSetRelayTableIndex
Integer32,
genSetRelayTableEnable
DisplayString,
genSetRelayTableEs
Integer32,
genSetRelayTablePoint
Integer32,
genSetRelayTableRunningstate
DisplayString
}
CRDBFileEnforceMinConfig ::=
SEQUENCE {
sysCRDBFileEnforceMinIndex
Integer32,
sysCRDBFileEnforceMin
DisplayString
}
CRDBFileIDConfig ::=
SEQUENCE {
sysCRDBFileIDIndex
Integer32,
sysCRDBFileID
DisplayString
}
NetworkTimeHostConfig ::=
SEQUENCE {
sysTimeNetHostIndex
Integer32,
sysTimeNetHost
DisplayString
}
ActionHostConfig ::=
SEQUENCE {
actionHostIndex
Integer32,
actionHost
DisplayString
}
ActionEmailConfig ::=
SEQUENCE {
actionEmailIndex
Integer32,
actionEmail
DisplayString
}
FileEnforceMinimumConfig ::=
SEQUENCE {
sysCRDBFileEnforceMinIndex
Integer32,
sysCRDBFileEnforceMin
DisplayString
}
SerialHandshakingLowEventConfig ::=
SEQUENCE {
evShskLowIndex
Integer32,
evShskLowEnable
DisplayString,
evShskLowActions
DisplayString,
evShskLowMessage
DisplayString,
evShskLowClass
DisplayString,
evShskLowTrapNum
Integer32
}
SerialHandshakingHighEventConfig ::=
SEQUENCE {
evShskHighIndex
Integer32,
evShskHighEnable
DisplayString,
evShskHighActions
DisplayString,
evShskHighMessage
DisplayString,
evShskHighClass
DisplayString,
evShskHighTrapNum
Integer32
}
SecUserConfig ::=
SEQUENCE {
secUserIndex
Integer32,
secUserEnable
DisplayString,
secUserConnectVia
DisplayString,
secUserLoginTo
DisplayString,
secUserAccessFile
DisplayString,
secUserPTEscapeTo
DisplayString,
secUserRights
DisplayString,
secUserEventsReadAccess
DisplayString,
secUserAuditReadAccess
DisplayString,
secUserEventsWriteAccess
DisplayString,
secUserAuditWriteAccess
DisplayString,
secUserExpiration
DisplayString,
secUserChallengeConsoleMode
DisplayString,
secUserChallengeExpiration
Integer32
}
IPRestrictionConfig ::=
SEQUENCE {
ipRestrictionIndex
Integer32,
ipRestrictionEnable
DisplayString,
ipRestrictionMask
DisplayString
}
DNSConfig ::=
SEQUENCE {
dnsIndex
Integer32,
dnsAddress
IpAddress
}
HostConfig ::=
SEQUENCE {
hostIndex
Integer32,
hostDeclaration
DisplayString
}
SNMPProxyTable ::=
SEQUENCE {
snmpProxyIndex
Integer32,
snmpProxyEgressOIDBranch
DisplayString,
snmpProxyIP
DisplayString,
snmpProxyPort
Integer32,
snmpProxyIngressOIDBranch
DisplayString,
snmpProxyName
DisplayString
}
SNMPPollRequestConfig ::=
SEQUENCE {
snmpPRequestIndex
Integer32,
snmpPRequestDescription
DisplayString,
snmpPRequestAgent
DisplayString,
snmpPRequestReadcom
DisplayString,
snmpPRequestOID
DisplayString,
snmpPRequestPeriod
Integer32,
snmpPRequestResultStatus
DisplayString,
snmpPRequestResultValue
DisplayString,
snmpPRequestResultTime
DisplayString,
snmpPRequestResultType
DisplayString
}
FTPPushPushFileConfig ::=
SEQUENCE {
ftpPushPushFileIndex
Integer32,
ftpPushPushFile
DisplayString
}
FTPPushRemoteFileConfig ::=
SEQUENCE {
ftpPushRemoteFileIndex
Integer32,
ftpPushRemoteFileName
DisplayString
}
PortConfig ::=
SEQUENCE {
portConfigIndex
Integer32,
portConfigBaud
Integer32,
portConfigDataFormat
Integer32,
portConfigStripPtOutputLfs
Integer32,
portConfigStripPtInputLfs
Integer32,
portConfigId
DisplayString,
portConfigMode
DisplayString,
portConfigHsk
DisplayString
}
ESPoint ::=
SEQUENCE {
esIndexES
Integer32,
esIndexPC
Integer32,
esIndexPoint
Integer32,
esPointName
DisplayString,
esPointInEventState
Integer32,
esPointValueInt
Integer32,
esPointValueStr
DisplayString,
esPointTimeLastChange
DisplayString,
esPointTimetickLastChange
TimeTicks,
esPointAliasValueStr
DisplayString
}
ESExist ::=
SEQUENCE {
esIndex
Integer32,
esName
DisplayString,
esID
DisplayString,
esNumberTempSensors
Integer32,
esTempReportingMode
DisplayString,
esNumberCCs
Integer32,
esCCReportingMode
DisplayString,
esNumberHumidSensors
Integer32,
esHumidReportingMode
DisplayString,
esNumberNoiseSensors
Integer32,
esNoiseReportingMode
DisplayString,
esNumberAirflowSensors
Integer32,
esAirflowReportingMode
DisplayString,
esNumberAnalog
Integer32,
esAnalogReportingMode
DisplayString,
esNumberOutputs
Integer32,
esOutputReportingMode
DisplayString,
esTempCombinedStatus
DisplayString,
esCCCombinedStatusBlock1
DisplayString,
esCCCombinedStatusBlock2
DisplayString,
esCCCombinedStatusBlock3
DisplayString,
esCCCombinedStatusBlock4
DisplayString,
esCCCombinedStatusBlock5
DisplayString,
esCCCombinedStatusBlock6
DisplayString,
esCCCombinedStatusBlock7
DisplayString,
esCCCombinedStatusBlock8
DisplayString,
esHumidCombinedStatus
DisplayString,
esAnalogCombinedStatusBlock1
DisplayString,
esAnalogCombinedStatusBlock2
DisplayString,
esAnalogCombinedStatusBlock3
DisplayString,
esAnalogCombinedStatusBlock4
DisplayString,
esAnalogCombinedStatusBlock5
DisplayString,
esAnalogCombinedStatusBlock6
DisplayString,
esOutputCombinedStatusBlock1
DisplayString,
esOutputCombinedStatusBlock2
DisplayString
}
DEStatus ::=
SEQUENCE {
deStatusIndex
Integer32,
deStatusName
DisplayString,
deStatusCounter
Integer32,
deStatusThreshold
Integer32
}
FSStatus ::=
SEQUENCE {
fsStatusIndex
Integer32,
fsStatusName
DisplayString,
fsStatusDeviceState
DisplayString,
fsStatusVolumeValueString
DisplayString,
fsStatusVolumePercentLevel
DisplayString,
fsStatusVolumeInEventState
DisplayString,
fsStatusCombined
DisplayString
}
ACPMStatus ::=
SEQUENCE {
acpmsIndex
Integer32,
acpmsName
DisplayString,
acpmsAvgVoltageValueStr
DisplayString,
acpmsAvgVoltageMinStr
DisplayString,
acpmsAvgVoltageMaxStr
DisplayString,
acpmsAvgVoltageAvgStr
DisplayString,
acpmsAvgVoltageInEventState
DisplayString,
acpmsVoltagePhaseAValueStr
DisplayString,
acpmsVoltagePhaseBValueStr
DisplayString,
acpmsVoltagePhaseCValueStr
DisplayString,
acpmsAvgCurrentValueStr
DisplayString,
acpmsAvgCurrentMinStr
DisplayString,
acpmsAvgCurrentMaxStr
DisplayString,
acpmsAvgCurrentAvgStr
DisplayString,
acpmsAvgCurrentInEventState
DisplayString,
acpmsCurrentPhaseAValueStr
DisplayString,
acpmsCurrentPhaseBValueStr
DisplayString,
acpmsCurrentPhaseCValueStr
DisplayString,
acpmsAvgFreqValueStr
DisplayString,
acpmsAvgFreqMinStr
DisplayString,
acpmsAvgFreqMaxStr
DisplayString,
acpmsAvgFreqAvgStr
DisplayString,
acpmsAvgFreqInEventState
DisplayString,
acpmsTRPValueStr
DisplayString,
acpmsTRPMinStr
DisplayString,
acpmsTRPMaxStr
DisplayString,
acpmsTRPAvgStr
DisplayString,
acpmsTRPInEventState
DisplayString,
acpmsRPPhaseAValueStr
DisplayString,
acpmsRPPhaseBValueStr
DisplayString,
acpmsRPPhaseCValueStr
DisplayString,
acpmsCombined
DisplayString,
acpmsTPFValueStr
DisplayString,
acpmsTPFMinStr
DisplayString,
acpmsTPFMaxStr
DisplayString,
acpmsTPFAvgStr
DisplayString,
acpmsTPFInEventState
DisplayString,
acpmsPFPhaseAValueStr
DisplayString,
acpmsPFPhaseBValueStr
DisplayString,
acpmsPFPhaseCValueStr
DisplayString,
acpmsTRcPValueStr
DisplayString,
acpmsTRcPMinStr
DisplayString,
acpmsTRcPMaxStr
DisplayString,
acpmsTRcPAvgStr
DisplayString,
acpmsRcPPhaseAValueStr
DisplayString,
acpmsRcPPhaseBValueStr
DisplayString,
acpmsRcPPhaseCValueStr
DisplayString,
acpmsTAPValueStr
DisplayString,
acpmsTAPMinStr
DisplayString,
acpmsTAPMaxStr
DisplayString,
acpmsTAPAvgStr
DisplayString,
acpmsAPPhaseAValueStr
DisplayString,
acpmsAPPhaseBValueStr
DisplayString,
acpmsAPPhaseCValueStr
DisplayString,
acpmsTotalEnergyWh
Integer32,
acpmsTotalEnergyVAR
Integer32,
acpmsTotalEnergyVA
Integer32
}
ScheduleConfig ::=
SEQUENCE {
schedIndex
Integer32,
schedEnable
DisplayString,
schedStart
DisplayString,
schedRepeatMode
DisplayString,
schedRepeatFreq
Integer32,
schedRepeatEndMode
DisplayString,
schedRepeatEndAfter
Integer32,
schedRepeatEndOn
DisplayString,
schedRepeatWeeklySun
DisplayString,
schedRepeatWeeklyMon
DisplayString,
schedRepeatWeeklyTue
DisplayString,
schedRepeatWeeklyWed
DisplayString,
schedRepeatWeeklyThu
DisplayString,
schedRepeatWeeklyFri
DisplayString,
schedRepeatWeeklySat
DisplayString,
schedRepeatMonthlyMode
DisplayString,
schedRepeatMonthlyDates
DisplayString,
schedRepeatMonthlyOnThe
DisplayString,
schedRepeatMonthlyOnDay
DisplayString,
schedRepeatYearlyJan
DisplayString,
schedRepeatYearlyFeb
DisplayString,
schedRepeatYearlyMar
DisplayString,
schedRepeatYearlyApr
DisplayString,
schedRepeatYearlyMay
DisplayString,
schedRepeatYearlyJun
DisplayString,
schedRepeatYearlyJul
DisplayString,
schedRepeatYearlyAug
DisplayString,
schedRepeatYearlySep
DisplayString,
schedRepeatYearlyOct
DisplayString,
schedRepeatYearlyNov
DisplayString,
schedRepeatYearlyDec
DisplayString,
schedRepeatYearlyOnThe
DisplayString,
schedRepeatYearlyOnDay
DisplayString,
schedNextTrigger
DisplayString
}
FuelSensorConfigGeneral ::=
SEQUENCE {
fsGenIndex
Integer32,
fsGenName
DisplayString,
fsGenSensorType
DisplayString,
fsGenDistanceUnit
DisplayString,
fsGenRawValueTop
DisplayString,
fsGenTopOffset
DisplayString,
fsGenRawValueBottom
DisplayString,
fsGenBottomOffset
DisplayString,
fsGenInputES
Integer32,
fsGenInputPoint
Integer32,
fsGenFilterAveraging
Integer32,
fsGenSysrepEnable
DisplayString,
fsGenSysrepThreshold
DisplayString,
fsGenSysrepLimit
Integer32,
fsGenSysrepPackage
Integer32,
fsGenSysrepType
DisplayString,
fsGenEnable
DisplayString
}
FuelSensorConfigTank ::=
SEQUENCE {
fsTankIndex
Integer32,
fsTankHeight
DisplayString,
fsTankDimA
DisplayString,
fsTankDimB
DisplayString,
fsTankVolume
DisplayString,
fsTankVolumeUnit
DisplayString,
fsTankShape
DisplayString
}
FuelSensorConfigCustomTankStrapping ::=
SEQUENCE {
fsCustomTankIndexFS
Integer32,
fsCustomTankIndexDatum
Integer32,
fsCustomTankHeight
DisplayString,
fsCustomTankVolume
DisplayString
}
FuelSensorConfigVolume ::=
SEQUENCE {
fsVolumeIndex
Integer32,
fsVolumeEnable
DisplayString,
fsVolumeDeadband
DisplayString,
fsVolumeVHighValue
DisplayString,
fsVolumeVHighActions
DisplayString,
fsVolumeVHighTrapNum
Integer32,
fsVolumeVHighClass
DisplayString,
fsVolumeHighValue
DisplayString,
fsVolumeHighActions
DisplayString,
fsVolumeHighTrapNum
Integer32,
fsVolumeHighClass
DisplayString,
fsVolumeNormalActions
DisplayString,
fsVolumeNormalTrapNum
Integer32,
fsVolumeNormalClass
DisplayString,
fsVolumeLowValue
DisplayString,
fsVolumeLowActions
DisplayString,
fsVolumeLowTrapNum
Integer32,
fsVolumeLowClass
DisplayString,
fsVolumeVLowValue
DisplayString,
fsVolumeVLowActions
DisplayString,
fsVolumeVLowTrapNum
Integer32,
fsVolumeVLowClass
DisplayString
}
FuelSensorConfigDisconnect ::=
SEQUENCE {
fsDiscIndex
Integer32,
fsDiscEnable
DisplayString,
fsDiscHighValue
DisplayString,
fsDiscLowValue
DisplayString,
fsDiscActions
DisplayString,
fsDiscTrapNum
Integer32,
fsDiscClass
DisplayString,
fsDiscNormalActions
DisplayString,
fsDiscNormalTrapNum
Integer32,
fsDiscNormalClass
DisplayString
}
FuelSensorConfigSuddenChange ::=
SEQUENCE {
fsSuddenChangeIndex
Integer32,
fsSuddenChangeEnable
DisplayString,
fsSuddenChangeTime
Integer32,
fsSuddenChangeAmplitude
DisplayString,
fsSuddenChangeActions
DisplayString,
fsSuddenChangeTrapNum
Integer32,
fsSuddenChangeClass
DisplayString
}
FuelSensorConfigSlowChange ::=
SEQUENCE {
fsSlowChangeIndex
Integer32,
fsSlowChangeEnable
DisplayString,
fsSlowChangeTime
Integer32,
fsSlowChangeAmplitude
DisplayString,
fsSlowChangeActions
DisplayString,
fsSlowChangeTrapNum
Integer32,
fsSlowChangeClass
DisplayString
}
FuelSensorConfigLevelsAutoAdjust ::=
SEQUENCE {
fsLAAIndex
Integer32,
fsLAAEnable
DisplayString,
fsLAAEventEnable
DisplayString,
fsLAAEventThreshold
Integer32,
fsLAAEventActions
DisplayString,
fsLAAEventClass
DisplayString,
fsLAAEventTrapNum
Integer32
}
ACPMConfigGeneral ::=
SEQUENCE {
acpmGenIndex
Integer32,
acpmGenDevice
DisplayString,
acpmGenName
DisplayString,
acpmGenAddress
Integer32,
acpmGenPtRatio
Integer32,
acpmGenCtRatio
Integer32,
acpmGenPowerType
DisplayString,
acpmGenSysrepPackage
Integer32,
acpmGenSysrepType
DisplayString,
acpmGenEnable
DisplayString
}
ACPMConfigAvgVoltage ::=
SEQUENCE {
acpmAvgVoltageIndex
Integer32,
acpmAvgVoltageEnable
DisplayString,
acpmAvgVoltageDeadband
DisplayString,
acpmAvgVoltageVHighValue
DisplayString,
acpmAvgVoltageVHighActions
DisplayString,
acpmAvgVoltageVHighTrapNum
Integer32,
acpmAvgVoltageVHighClass
DisplayString,
acpmAvgVoltageHighValue
DisplayString,
acpmAvgVoltageHighActions
DisplayString,
acpmAvgVoltageHighTrapNum
Integer32,
acpmAvgVoltageHighClass
DisplayString,
acpmAvgVoltageNormalActions
DisplayString,
acpmAvgVoltageNormalTrapNum
Integer32,
acpmAvgVoltageNormalClass
DisplayString,
acpmAvgVoltageLowValue
DisplayString,
acpmAvgVoltageLowActions
DisplayString,
acpmAvgVoltageLowTrapNum
Integer32,
acpmAvgVoltageLowClass
DisplayString,
acpmAvgVoltageVLowValue
DisplayString,
acpmAvgVoltageVLowActions
DisplayString,
acpmAvgVoltageVLowTrapNum
Integer32,
acpmAvgVoltageVLowClass
DisplayString,
acpmAvgVoltageSysrepEnable
DisplayString,
acpmAvgVoltageSysrepThreshold
DisplayString,
acpmAvgVoltageSysrepLimit
Integer32
}
ACPMConfigAvgCurrent ::=
SEQUENCE {
acpmAvgCurrentIndex
Integer32,
acpmAvgCurrentEnable
DisplayString,
acpmAvgCurrentDeadband
DisplayString,
acpmAvgCurrentVHighValue
DisplayString,
acpmAvgCurrentVHighActions
DisplayString,
acpmAvgCurrentVHighTrapNum
Integer32,
acpmAvgCurrentVHighClass
DisplayString,
acpmAvgCurrentHighValue
DisplayString,
acpmAvgCurrentHighActions
DisplayString,
acpmAvgCurrentHighTrapNum
Integer32,
acpmAvgCurrentHighClass
DisplayString,
acpmAvgCurrentNormalActions
DisplayString,
acpmAvgCurrentNormalTrapNum
Integer32,
acpmAvgCurrentNormalClass
DisplayString,
acpmAvgCurrentLowValue
DisplayString,
acpmAvgCurrentLowActions
DisplayString,
acpmAvgCurrentLowTrapNum
Integer32,
acpmAvgCurrentLowClass
DisplayString,
acpmAvgCurrentVLowValue
DisplayString,
acpmAvgCurrentVLowActions
DisplayString,
acpmAvgCurrentVLowTrapNum
Integer32,
acpmAvgCurrentVLowClass
DisplayString,
acpmAvgCurrentSysrepEnable
DisplayString,
acpmAvgCurrentSysrepThreshold
DisplayString,
acpmAvgCurrentSysrepLimit
Integer32
}
ACPMConfigFreq ::=
SEQUENCE {
acpmFreqIndex
Integer32,
acpmFreqEnable
DisplayString,
acpmFreqDeadband
DisplayString,
acpmFreqVHighValue
DisplayString,
acpmFreqVHighActions
DisplayString,
acpmFreqVHighTrapNum
Integer32,
acpmFreqVHighClass
DisplayString,
acpmFreqHighValue
DisplayString,
acpmFreqHighActions
DisplayString,
acpmFreqHighTrapNum
Integer32,
acpmFreqHighClass
DisplayString,
acpmFreqNormalActions
DisplayString,
acpmFreqNormalTrapNum
Integer32,
acpmFreqNormalClass
DisplayString,
acpmFreqLowValue
DisplayString,
acpmFreqLowActions
DisplayString,
acpmFreqLowTrapNum
Integer32,
acpmFreqLowClass
DisplayString,
acpmFreqVLowValue
DisplayString,
acpmFreqVLowActions
DisplayString,
acpmFreqVLowTrapNum
Integer32,
acpmFreqVLowClass
DisplayString,
acpmFreqSysrepEnable
DisplayString,
acpmFreqSysrepThreshold
DisplayString,
acpmFreqSysrepLimit
Integer32
}
ACPMConfigTRP ::=
SEQUENCE {
acpmTRPIndex
Integer32,
acpmTRPEnable
DisplayString,
acpmTRPDeadband
DisplayString,
acpmTRPVHighValue
DisplayString,
acpmTRPVHighActions
DisplayString,
acpmTRPVHighTrapNum
Integer32,
acpmTRPVHighClass
DisplayString,
acpmTRPHighValue
DisplayString,
acpmTRPHighActions
DisplayString,
acpmTRPHighTrapNum
Integer32,
acpmTRPHighClass
DisplayString,
acpmTRPNormalActions
DisplayString,
acpmTRPNormalTrapNum
Integer32,
acpmTRPNormalClass
DisplayString,
acpmTRPLowValue
DisplayString,
acpmTRPLowActions
DisplayString,
acpmTRPLowTrapNum
Integer32,
acpmTRPLowClass
DisplayString,
acpmTRPVLowValue
DisplayString,
acpmTRPVLowActions
DisplayString,
acpmTRPVLowTrapNum
Integer32,
acpmTRPVLowClass
DisplayString,
acpmTRPSysrepEnable
DisplayString,
acpmTRPSysrepThreshold
DisplayString,
acpmTRPSysrepLimit
Integer32
}
ACPMConfigDisconnect ::=
SEQUENCE {
acpmDisconnectIndex
Integer32,
acpmDisconnectEnable
DisplayString,
acpmDisconnectActions
DisplayString,
acpmDisconnectTrapNum
Integer32,
acpmDisconnectClass
DisplayString,
acpmDisconnectNormalActions
DisplayString,
acpmDisconnectNormalTrapNum
Integer32,
acpmDisconnectNormalClass
DisplayString
}
ACPMConfigTotalPowerFactor ::=
SEQUENCE {
acpmTPFIndex
Integer32,
acpmTPFEnable
DisplayString,
acpmTPFDeadband
DisplayString,
acpmTPFNormalActions
DisplayString,
acpmTPFNormalTrapNum
Integer32,
acpmTPFNormalClass
DisplayString,
acpmTPFLowValue
DisplayString,
acpmTPFLowActions
DisplayString,
acpmTPFLowTrapNum
Integer32,
acpmTPFLowClass
DisplayString,
acpmTPFVLowValue
DisplayString,
acpmTPFVLowActions
DisplayString,
acpmTPFVLowTrapNum
Integer32,
acpmTPFVLowClass
DisplayString,
acpmTPFSysrepEnable
DisplayString,
acpmTPFSysrepThreshold
DisplayString,
acpmTPFSysrepLimit
Integer32
}
BatteryMonitorConfigGeneral ::=
SEQUENCE {
bmGenIndex
Integer32,
bmGenEnable
DisplayString,
bmGenName
DisplayString,
bmGenBatteryQuantity
Integer32,
bmGenBatteryCapacity
Integer32,
bmGenBatteryNominalVoltage
DisplayString,
bmGenSysrepPackage
Integer32,
bmGenSysrepType
DisplayString
}
BatteryMonitorConfigDevice ::=
SEQUENCE {
bmDeviceIndex
Integer32,
bmDeviceType
DisplayString,
bmDeviceES
Integer32,
bmDeviceIP
IpAddress,
bmDeviceReadcom
DisplayString,
bmDeviceInputString
Integer32,
bmDeviceCTSize
Integer32
}
BatteryMonitorConfigTemp ::=
SEQUENCE {
bmTempIndex
Integer32,
bmTempEnable
DisplayString,
bmTempDeadband
DisplayString,
bmTempScale
DisplayString,
bmTempHighValue
DisplayString,
bmTempHighActions
DisplayString,
bmTempHighTrapNum
Integer32,
bmTempHighClass
DisplayString,
bmTempNormalActions
DisplayString,
bmTempNormalTrapNum
Integer32,
bmTempNormalClass
DisplayString,
bmTempLowValue
DisplayString,
bmTempLowActions
DisplayString,
bmTempLowTrapNum
Integer32,
bmTempLowClass
DisplayString,
bmTempSysrepEnable
DisplayString,
bmTempSysrepThreshold
DisplayString,
bmTempSysrepLimit
Integer32
}
BatteryMonitorConfigDiffTemp ::=
SEQUENCE {
bmDiffTempIndex
Integer32,
bmDiffTempEnable
DisplayString,
bmDiffTempDeadband
Integer32,
bmDiffTempVHighValue
Integer32,
bmDiffTempVHighActions
DisplayString,
bmDiffTempVHighTrapNum
Integer32,
bmDiffTempVHighClass
DisplayString,
bmDiffTempHighValue
Integer32,
bmDiffTempHighActions
DisplayString,
bmDiffTempHighTrapNum
Integer32,
bmDiffTempHighClass
DisplayString,
bmDiffTempNormalActions
DisplayString,
bmDiffTempNormalTrapNum
Integer32,
bmDiffTempNormalClass
DisplayString,
bmDiffTempSysrepEnable
DisplayString,
bmDiffTempSysrepThreshold
Integer32,
bmDiffTempSysrepLimit
Integer32
}
BatteryMonitorConfigVoltage ::=
SEQUENCE {
bmVoltageIndex
Integer32,
bmVoltageEnable
DisplayString,
bmVoltageDeadband
DisplayString,
bmVoltageVHighValue
DisplayString,
bmVoltageVHighActions
DisplayString,
bmVoltageVHighTrapNum
Integer32,
bmVoltageVHighClass
DisplayString,
bmVoltageHighValue
DisplayString,
bmVoltageHighActions
DisplayString,
bmVoltageHighTrapNum
Integer32,
bmVoltageHighClass
DisplayString,
bmVoltageNormalActions
DisplayString,
bmVoltageNormalTrapNum
Integer32,
bmVoltageNormalClass
DisplayString,
bmVoltageLowValue
DisplayString,
bmVoltageLowActions
DisplayString,
bmVoltageLowTrapNum
Integer32,
bmVoltageLowClass
DisplayString,
bmVoltageVLowValue
DisplayString,
bmVoltageVLowActions
DisplayString,
bmVoltageVLowTrapNum
Integer32,
bmVoltageVLowClass
DisplayString,
bmVoltageSysrepEnable
DisplayString,
bmVoltageSysrepThreshold
DisplayString,
bmVoltageSysrepLimit
Integer32
}
BatteryMonitorConfigDiffVolt ::=
SEQUENCE {
bmDiffVoltIndex
Integer32,
bmDiffVoltEnable
DisplayString,
bmDiffVoltDeadband
DisplayString,
bmDiffVoltVHighValue
DisplayString,
bmDiffVoltVHighActions
DisplayString,
bmDiffVoltVHighTrapNum
Integer32,
bmDiffVoltVHighClass
DisplayString,
bmDiffVoltHighValue
DisplayString,
bmDiffVoltHighActions
DisplayString,
bmDiffVoltHighTrapNum
Integer32,
bmDiffVoltHighClass
DisplayString,
bmDiffVoltNormalActions
DisplayString,
bmDiffVoltNormalTrapNum
Integer32,
bmDiffVoltNormalClass
DisplayString,
bmDiffVoltSysrepEnable
DisplayString,
bmDiffVoltSysrepThreshold
DisplayString,
bmDiffVoltSysrepLimit
Integer32
}
BatteryMonitorConfigChargingCurrent ::=
SEQUENCE {
bmChargingCurrentIndex
Integer32,
bmChargingCurrentEnable
DisplayString,
bmChargingCurrentDeadband
DisplayString,
bmChargingCurrentVHighValue
DisplayString,
bmChargingCurrentVHighActions
DisplayString,
bmChargingCurrentVHighTrapNum
Integer32,
bmChargingCurrentVHighClass
DisplayString,
bmChargingCurrentHighValue
DisplayString,
bmChargingCurrentHighActions
DisplayString,
bmChargingCurrentHighTrapNum
Integer32,
bmChargingCurrentHighClass
DisplayString,
bmChargingCurrentNormalActions
DisplayString,
bmChargingCurrentNormalTrapNum
Integer32,
bmChargingCurrentNormalClass
DisplayString,
bmChargingCurrentSysrepEnable
DisplayString,
bmChargingCurrentSysrepThreshold
DisplayString,
bmChargingCurrentSysrepLimit
Integer32
}
BatteryMonitorConfigDischargingCurrent ::=
SEQUENCE {
bmDischargingCurrentIndex
Integer32,
bmDischargingCurrentEnable
DisplayString,
bmDischargingCurrentDeadband
DisplayString,
bmDischargingCurrentVHighValue
DisplayString,
bmDischargingCurrentVHighActions
DisplayString,
bmDischargingCurrentVHighTrapNum
Integer32,
bmDischargingCurrentVHighClass
DisplayString,
bmDischargingCurrentHighValue
DisplayString,
bmDischargingCurrentHighActions
DisplayString,
bmDischargingCurrentHighTrapNum
Integer32,
bmDischargingCurrentHighClass
DisplayString,
bmDischargingCurrentNormalActions
DisplayString,
bmDischargingCurrentNormalTrapNum
Integer32,
bmDischargingCurrentNormalClass
DisplayString,
bmDischargingCurrentSysrepEnable
DisplayString,
bmDischargingCurrentSysrepThreshold
DisplayString,
bmDischargingCurrentSysrepLimit
Integer32
}
BatteryMonitorConfigChargeLevel ::=
SEQUENCE {
bmChargeLevelIndex
Integer32,
bmChargeLevelEnable
DisplayString,
bmChargeLevelNormalActions
DisplayString,
bmChargeLevelNormalTrapNum
Integer32,
bmChargeLevelNormalClass
DisplayString,
bmChargeLevelLowActions
DisplayString,
bmChargeLevelLowTrapNum
Integer32,
bmChargeLevelLowClass
DisplayString,
bmChargeLevelVLowActions
DisplayString,
bmChargeLevelVLowTrapNum
Integer32,
bmChargeLevelVLowClass
DisplayString,
bmChargeLevelSysrepEnable
DisplayString
}
BatteryMonitorConfigJarHealth ::=
SEQUENCE {
bmJarHealthIndex
Integer32,
bmJarHealthEnable
DisplayString,
bmJarHealthNormalActions
DisplayString,
bmJarHealthNormalTrapNum
Integer32,
bmJarHealthNormalClass
DisplayString,
bmJarHealthLowActions
DisplayString,
bmJarHealthLowTrapNum
Integer32,
bmJarHealthLowClass
DisplayString,
bmJarHealthVLowActions
DisplayString,
bmJarHealthVLowTrapNum
Integer32,
bmJarHealthVLowClass
DisplayString,
bmJarHealthSysrepEnable
DisplayString
}
BMStatus ::=
SEQUENCE {
bmsIndex
Integer32,
bmsEnable
DisplayString,
bmsName
DisplayString,
bmsState
DisplayString,
bmsStringState
DisplayString,
bmsTempValue
DisplayString,
bmsTempValueStr
DisplayString,
bmsTempEvent
DisplayString,
bmsDiffTempValue
Integer32,
bmsDiffTempValueStr
DisplayString,
bmsDiffTempEvent
DisplayString,
bmsVoltageValue
DisplayString,
bmsVoltageEvent
DisplayString,
bmsDiffVoltValue
DisplayString,
bmsDiffVoltEvent
DisplayString,
bmsCurrentValue
DisplayString,
bmsChargingCurrentEvent
DisplayString,
bmsDischargingCurrentEvent
DisplayString,
bmsChargeLevelValue
DisplayString,
bmsChargeLevelEvent
DisplayString,
bmsJarHealthValue
DisplayString,
bmsJarHealthEvent
DisplayString,
bmsCombined
DisplayString
}
BMJarStatus ::=
SEQUENCE {
bmjsIndexBM
Integer32,
bmjsIndexJar
Integer32,
bmjsVoltageValue
DisplayString,
bmjsTempValue
DisplayString,
bmjsAdmittanceValue
Integer32,
bmjsAdmittanceChangeValue
Integer32
}
AccessControlDevice ::=
SEQUENCE {
acdIndex
Integer32,
acdEnable
DisplayString,
acdName
DisplayString,
acdReader
DisplayString,
acdWiegandES
Integer32,
acdRelayType
DisplayString,
acdRelayES
Integer32,
acdRelayPoint
Integer32,
acdOpenTime
Integer32,
acdUserGroup
Integer32
}
AccessControlUser ::=
SEQUENCE {
acuIndexUserGroup
Integer32,
acuIndexUser
Integer32,
acuEnable
DisplayString,
acuName
DisplayString,
acuSn
DisplayString,
acuSunBegin
DisplayString,
acuSunEnd
DisplayString,
acuMonBegin
DisplayString,
acuMonEnd
DisplayString,
acuTueBegin
DisplayString,
acuTueEnd
DisplayString,
acuWedBegin
DisplayString,
acuWedEnd
DisplayString,
acuThuBegin
DisplayString,
acuThuEnd
DisplayString,
acuFriBegin
DisplayString,
acuFriEnd
DisplayString,
acuSatBegin
DisplayString,
acuSatEnd
DisplayString
}
--***************************************************************************************
--TRAP DEFINITIONS
--***************************************************************************************
s350StockContactClosureTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock contact closure trap is issued when a contact closure
event happens."
::= { s350Notifications 110 }
s350StockTempTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock temperature trap is issued when a temperature event
happens."
::= { s350Notifications 120 }
s350StockHumidityTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock humidity trap is issued when a humidity event
happens."
::= { s350Notifications 130 }
s350StockAnalogTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock analog trap is issued when an analog sensor event
happens."
::= { s350Notifications 140 }
s350StockOutputTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock output trap is issued when an output event
happens. That is, depending on the configuration,
when an output changes state for any reason, this
trap will be sent."
::= { s350Notifications 150 }
s350StockPDCurrentTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock analog trap is issued when a power distribution
current event happens."
::= { s350Notifications 180 }
s350StockPDVoltageTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock analog trap is issued when a power distribution
voltage event happens."
::= { s350Notifications 190 }
s350StockPDFuseTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock analog trap is issued when a power distribution
fuse event happens."
::= { s350Notifications 210 }
s350StockSchedTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"The stock scheduled alarm trap is issued
when the current time reaches the scheduled
alarm time."
::= { s350Notifications 506 }
s350StockImmediateTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"The stock immediate alarm trap is issued
when the user enters the DOTRAP command."
::= { s350Notifications 507 }
s350StockCTSTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock CTS trap is issued when an RS-232 CTS event
happens."
::= { s350Notifications 510 }
s350CPEDownTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock CPE Down trap is issued when a CPE Down event
happens."
::= { s350Notifications 511 }
s350FuelSensorDisconnectTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock Fuel Sensor Disconnect trap is issued when a Fuel
Sensor Disconnect or Connect (Return to Normal) event happens."
::= { s350Notifications 515 }
s350FuelSensorVolumeTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock Fuel Sensor Volume trap is issued when a Fuel
Sensor Volume event happens"
::= { s350Notifications 519 }
s350ACPowerMonitorAvgVoltageTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock AC power monitor average voltage trap is issued when an
AC power monitor average voltage event happens."
::= { s350Notifications 520 }
s350ACPowerMonitorAvgCurrentTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock AC power monitor average current trap is issued when an
AC power monitor average current event happens."
::= { s350Notifications 521 }
s350ACPowerMonitorFrequencyTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock AC power monitor frequency trap is issued when an
AC power monitor frequency event happens."
::= { s350Notifications 522 }
s350ACPowerMonitorTRPTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock AC power monitor TRP (total real power) trap is issued
when an AC power monitor TRP event happens."
::= { s350Notifications 523 }
s350ACPowerMonitorDisconnectTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock AC power monitor disconnect trap is issued
when an AC power monitor disconnect event happens."
::= { s350Notifications 524 }
s350StockScriptTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock script trap is issued when a script triggers
an event via a_lib.PostEvent() called with no trap
number (or this trap number) specified."
::= { s350Notifications 526 }
s350FuelSensorVolumeSuddenChangeTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock Fuel Sensor Volume Sudden Change trap is issued
when a Fuel Sensor Volume Sudden Change event happens"
::= { s350Notifications 527 }
s350FuelSensorVolumeSlowChangeTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock Fuel Sensor Volume Slow Change trap is issued
when a Fuel Sensor Volume Slow Change event happens"
::= { s350Notifications 528 }
s350BattMonStringTemperatureTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock Battery Monitor String Temperature trap is issued
when a Battery Monitor String Temperature event happens."
::= { s350Notifications 530 }
s350BattMonStringDiffTemperatureTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock Battery Monitor String Differential Temperature
trap is issued when a Battery Monitor String Differential
Temperature event happens."
::= { s350Notifications 531 }
s350BattMonStringVoltageTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock Battery Monitor String Voltage trap is issued
when a Battery Monitor String Voltage event happens."
::= { s350Notifications 532 }
s350BattMonStringChargeLevelTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock Battery Monitor String Charge Level trap is issued
when a Battery Monitor String Charge Level event happens."
::= { s350Notifications 533 }
s350BattMonStringChargingCurrentTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock Battery Monitor String Charging Current trap is issued
when a Battery Monitor String Charging Current event happens."
::= { s350Notifications 534 }
s350BattMonStringDischargingCurrentTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock Battery Monitor String Discharging Current trap is issued
when a Battery Monitor String Discharging Current event happens."
::= { s350Notifications 535 }
s350GeneratorNonStartTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock Generator Non-start trap is issued
when the unit commands the generator to start as
part of the generator exercising feature, and the
generator fails to register as started after 30
seconds (as detected by CC generator running
detection)."
::= { s350Notifications 536 }
s350BattMonStringDifferentialVoltageTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock Battery Monitor String Differential Voltage trap is issued
when a Battery Monitor String Differential Voltage event happens."
::= { s350Notifications 537 }
s350BattMonStringJarHealthTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock Battery Monitor String Jar Health trap is issued
when a Battery Monitor String Jar Health event happens."
::= { s350Notifications 538 }
s350CameraTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock camera trap is issued when a camera event happens."
::= { s350Notifications 539 }
s350ACTotalPowerFactorTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock AC power monitor total power factor trap is issued
when an AC power monitor total power factor event happens."
::= { s350Notifications 540 }
s350LocationTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock location trap is issued when a location event happens."
::= { s350Notifications 541 }
s350SleepTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock sleep trap is issued when a sleep event happens."
::= { s350Notifications 542 }
s350ResetTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock reset trap is issued when a reset event happens."
::= { s350Notifications 543 }
s350FuelSensorLevelsAutoAdjustTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock fuel sensor levels auto-adjust trap is issued when
a fuel sensor levels auto-adjust event happens."
::= { s350Notifications 544 }
s350AccessControlTrap NOTIFICATION-TYPE
OBJECTS { siteName, stockTrapString, trapTypeString }
STATUS current
DESCRIPTION
"A stock access control trap is issued when an access control
device management event happens."
::= { s350Notifications 547 }
s350UserTrap1000 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1000."
::= { s350Notifications 1000 }
s350UserTrap1001 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1001."
::= { s350Notifications 1001 }
s350UserTrap1002 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1002."
::= { s350Notifications 1002 }
s350UserTrap1003 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1003."
::= { s350Notifications 1003 }
s350UserTrap1004 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1004."
::= { s350Notifications 1004 }
s350UserTrap1005 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1005."
::= { s350Notifications 1005 }
s350UserTrap1006 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1006."
::= { s350Notifications 1006 }
s350UserTrap1007 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1007."
::= { s350Notifications 1007 }
s350UserTrap1008 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1008."
::= { s350Notifications 1008 }
s350UserTrap1009 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1009."
::= { s350Notifications 1009 }
s350UserTrap1010 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1010."
::= { s350Notifications 1010 }
s350UserTrap1011 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1011."
::= { s350Notifications 1011 }
s350UserTrap1012 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1012."
::= { s350Notifications 1012 }
s350UserTrap1013 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1013."
::= { s350Notifications 1013 }
s350UserTrap1014 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1014."
::= { s350Notifications 1014 }
s350UserTrap1015 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1015."
::= { s350Notifications 1015 }
s350UserTrap1016 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1016."
::= { s350Notifications 1016 }
s350UserTrap1017 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1017."
::= { s350Notifications 1017 }
s350UserTrap1018 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1018."
::= { s350Notifications 1018 }
s350UserTrap1019 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1019."
::= { s350Notifications 1019 }
s350UserTrap1020 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1020."
::= { s350Notifications 1020 }
s350UserTrap1021 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1021."
::= { s350Notifications 1021 }
s350UserTrap1022 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1022."
::= { s350Notifications 1022 }
s350UserTrap1023 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1023."
::= { s350Notifications 1023 }
s350UserTrap1024 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1024."
::= { s350Notifications 1024 }
s350UserTrap1025 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1025."
::= { s350Notifications 1025 }
s350UserTrap1026 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1026."
::= { s350Notifications 1026 }
s350UserTrap1027 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1027."
::= { s350Notifications 1027 }
s350UserTrap1028 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1028."
::= { s350Notifications 1028 }
s350UserTrap1029 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1029."
::= { s350Notifications 1029 }
s350UserTrap1030 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1030."
::= { s350Notifications 1030 }
s350UserTrap1031 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1031."
::= { s350Notifications 1031 }
s350UserTrap1032 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1032."
::= { s350Notifications 1032 }
s350UserTrap1033 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1033."
::= { s350Notifications 1033 }
s350UserTrap1034 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1034."
::= { s350Notifications 1034 }
s350UserTrap1035 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1035."
::= { s350Notifications 1035 }
s350UserTrap1036 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1036."
::= { s350Notifications 1036 }
s350UserTrap1037 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1037."
::= { s350Notifications 1037 }
s350UserTrap1038 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1038."
::= { s350Notifications 1038 }
s350UserTrap1039 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1039."
::= { s350Notifications 1039 }
s350UserTrap1040 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1040."
::= { s350Notifications 1040 }
s350UserTrap1041 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1041."
::= { s350Notifications 1041 }
s350UserTrap1042 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1042."
::= { s350Notifications 1042 }
s350UserTrap1043 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1043."
::= { s350Notifications 1043 }
s350UserTrap1044 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1044."
::= { s350Notifications 1044 }
s350UserTrap1045 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1045."
::= { s350Notifications 1045 }
s350UserTrap1046 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1046."
::= { s350Notifications 1046 }
s350UserTrap1047 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1047."
::= { s350Notifications 1047 }
s350UserTrap1048 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1048."
::= { s350Notifications 1048 }
s350UserTrap1049 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1049."
::= { s350Notifications 1049 }
s350UserTrap1050 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1050."
::= { s350Notifications 1050 }
s350UserTrap1051 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1051."
::= { s350Notifications 1051 }
s350UserTrap1052 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1052."
::= { s350Notifications 1052 }
s350UserTrap1053 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1053."
::= { s350Notifications 1053 }
s350UserTrap1054 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1054."
::= { s350Notifications 1054 }
s350UserTrap1055 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1055."
::= { s350Notifications 1055 }
s350UserTrap1056 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1056."
::= { s350Notifications 1056 }
s350UserTrap1057 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1057."
::= { s350Notifications 1057 }
s350UserTrap1058 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1058."
::= { s350Notifications 1058 }
s350UserTrap1059 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1059."
::= { s350Notifications 1059 }
s350UserTrap1060 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1060."
::= { s350Notifications 1060 }
s350UserTrap1061 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1061."
::= { s350Notifications 1061 }
s350UserTrap1062 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1062."
::= { s350Notifications 1062 }
s350UserTrap1063 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1063."
::= { s350Notifications 1063 }
s350UserTrap1064 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1064."
::= { s350Notifications 1064 }
s350UserTrap1065 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1065."
::= { s350Notifications 1065 }
s350UserTrap1066 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1066."
::= { s350Notifications 1066 }
s350UserTrap1067 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1067."
::= { s350Notifications 1067 }
s350UserTrap1068 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1068."
::= { s350Notifications 1068 }
s350UserTrap1069 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1069."
::= { s350Notifications 1069 }
s350UserTrap1070 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1070."
::= { s350Notifications 1070 }
s350UserTrap1071 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1071."
::= { s350Notifications 1071 }
s350UserTrap1072 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1072."
::= { s350Notifications 1072 }
s350UserTrap1073 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1073."
::= { s350Notifications 1073 }
s350UserTrap1074 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1074."
::= { s350Notifications 1074 }
s350UserTrap1075 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1075."
::= { s350Notifications 1075 }
s350UserTrap1076 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1076."
::= { s350Notifications 1076 }
s350UserTrap1077 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1077."
::= { s350Notifications 1077 }
s350UserTrap1078 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1078."
::= { s350Notifications 1078 }
s350UserTrap1079 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1079."
::= { s350Notifications 1079 }
s350UserTrap1080 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1080."
::= { s350Notifications 1080 }
s350UserTrap1081 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1081."
::= { s350Notifications 1081 }
s350UserTrap1082 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1082."
::= { s350Notifications 1082 }
s350UserTrap1083 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1083."
::= { s350Notifications 1083 }
s350UserTrap1084 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1084."
::= { s350Notifications 1084 }
s350UserTrap1085 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1085."
::= { s350Notifications 1085 }
s350UserTrap1086 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1086."
::= { s350Notifications 1086 }
s350UserTrap1087 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1087."
::= { s350Notifications 1087 }
s350UserTrap1088 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1088."
::= { s350Notifications 1088 }
s350UserTrap1089 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1089."
::= { s350Notifications 1089 }
s350UserTrap1090 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1090."
::= { s350Notifications 1090 }
s350UserTrap1091 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1091."
::= { s350Notifications 1091 }
s350UserTrap1092 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1092."
::= { s350Notifications 1092 }
s350UserTrap1093 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1093."
::= { s350Notifications 1093 }
s350UserTrap1094 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1094."
::= { s350Notifications 1094 }
s350UserTrap1095 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1095."
::= { s350Notifications 1095 }
s350UserTrap1096 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1096."
::= { s350Notifications 1096 }
s350UserTrap1097 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1097."
::= { s350Notifications 1097 }
s350UserTrap1098 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1098."
::= { s350Notifications 1098 }
s350UserTrap1099 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1099."
::= { s350Notifications 1099 }
s350UserTrap1100 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1100."
::= { s350Notifications 1100 }
s350UserTrap1101 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1101."
::= { s350Notifications 1101 }
s350UserTrap1102 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1102."
::= { s350Notifications 1102 }
s350UserTrap1103 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1103."
::= { s350Notifications 1103 }
s350UserTrap1104 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1104."
::= { s350Notifications 1104 }
s350UserTrap1105 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1105."
::= { s350Notifications 1105 }
s350UserTrap1106 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1106."
::= { s350Notifications 1106 }
s350UserTrap1107 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1107."
::= { s350Notifications 1107 }
s350UserTrap1108 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1108."
::= { s350Notifications 1108 }
s350UserTrap1109 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1109."
::= { s350Notifications 1109 }
s350UserTrap1110 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1110."
::= { s350Notifications 1110 }
s350UserTrap1111 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1111."
::= { s350Notifications 1111 }
s350UserTrap1112 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1112."
::= { s350Notifications 1112 }
s350UserTrap1113 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1113."
::= { s350Notifications 1113 }
s350UserTrap1114 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1114."
::= { s350Notifications 1114 }
s350UserTrap1115 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1115."
::= { s350Notifications 1115 }
s350UserTrap1116 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1116."
::= { s350Notifications 1116 }
s350UserTrap1117 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1117."
::= { s350Notifications 1117 }
s350UserTrap1118 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1118."
::= { s350Notifications 1118 }
s350UserTrap1119 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1119."
::= { s350Notifications 1119 }
s350UserTrap1120 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1120."
::= { s350Notifications 1120 }
s350UserTrap1121 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1121."
::= { s350Notifications 1121 }
s350UserTrap1122 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1122."
::= { s350Notifications 1122 }
s350UserTrap1123 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1123."
::= { s350Notifications 1123 }
s350UserTrap1124 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1124."
::= { s350Notifications 1124 }
s350UserTrap1125 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1125."
::= { s350Notifications 1125 }
s350UserTrap1126 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1126."
::= { s350Notifications 1126 }
s350UserTrap1127 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1127."
::= { s350Notifications 1127 }
s350UserTrap1128 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1128."
::= { s350Notifications 1128 }
s350UserTrap1129 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1129."
::= { s350Notifications 1129 }
s350UserTrap1130 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1130."
::= { s350Notifications 1130 }
s350UserTrap1131 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1131."
::= { s350Notifications 1131 }
s350UserTrap1132 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1132."
::= { s350Notifications 1132 }
s350UserTrap1133 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1133."
::= { s350Notifications 1133 }
s350UserTrap1134 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1134."
::= { s350Notifications 1134 }
s350UserTrap1135 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1135."
::= { s350Notifications 1135 }
s350UserTrap1136 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1136."
::= { s350Notifications 1136 }
s350UserTrap1137 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1137."
::= { s350Notifications 1137 }
s350UserTrap1138 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1138."
::= { s350Notifications 1138 }
s350UserTrap1139 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1139."
::= { s350Notifications 1139 }
s350UserTrap1140 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1140."
::= { s350Notifications 1140 }
s350UserTrap1141 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1141."
::= { s350Notifications 1141 }
s350UserTrap1142 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1142."
::= { s350Notifications 1142 }
s350UserTrap1143 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1143."
::= { s350Notifications 1143 }
s350UserTrap1144 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1144."
::= { s350Notifications 1144 }
s350UserTrap1145 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1145."
::= { s350Notifications 1145 }
s350UserTrap1146 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1146."
::= { s350Notifications 1146 }
s350UserTrap1147 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1147."
::= { s350Notifications 1147 }
s350UserTrap1148 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1148."
::= { s350Notifications 1148 }
s350UserTrap1149 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1149."
::= { s350Notifications 1149 }
s350UserTrap1150 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1150."
::= { s350Notifications 1150 }
s350UserTrap1151 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1151."
::= { s350Notifications 1151 }
s350UserTrap1152 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1152."
::= { s350Notifications 1152 }
s350UserTrap1153 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1153."
::= { s350Notifications 1153 }
s350UserTrap1154 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1154."
::= { s350Notifications 1154 }
s350UserTrap1155 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1155."
::= { s350Notifications 1155 }
s350UserTrap1156 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1156."
::= { s350Notifications 1156 }
s350UserTrap1157 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1157."
::= { s350Notifications 1157 }
s350UserTrap1158 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1158."
::= { s350Notifications 1158 }
s350UserTrap1159 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1159."
::= { s350Notifications 1159 }
s350UserTrap1160 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1160."
::= { s350Notifications 1160 }
s350UserTrap1161 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1161."
::= { s350Notifications 1161 }
s350UserTrap1162 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1162."
::= { s350Notifications 1162 }
s350UserTrap1163 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1163."
::= { s350Notifications 1163 }
s350UserTrap1164 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1164."
::= { s350Notifications 1164 }
s350UserTrap1165 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1165."
::= { s350Notifications 1165 }
s350UserTrap1166 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1166."
::= { s350Notifications 1166 }
s350UserTrap1167 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1167."
::= { s350Notifications 1167 }
s350UserTrap1168 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1168."
::= { s350Notifications 1168 }
s350UserTrap1169 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1169."
::= { s350Notifications 1169 }
s350UserTrap1170 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1170."
::= { s350Notifications 1170 }
s350UserTrap1171 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1171."
::= { s350Notifications 1171 }
s350UserTrap1172 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1172."
::= { s350Notifications 1172 }
s350UserTrap1173 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1173."
::= { s350Notifications 1173 }
s350UserTrap1174 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1174."
::= { s350Notifications 1174 }
s350UserTrap1175 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1175."
::= { s350Notifications 1175 }
s350UserTrap1176 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1176."
::= { s350Notifications 1176 }
s350UserTrap1177 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1177."
::= { s350Notifications 1177 }
s350UserTrap1178 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1178."
::= { s350Notifications 1178 }
s350UserTrap1179 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1179."
::= { s350Notifications 1179 }
s350UserTrap1180 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1180."
::= { s350Notifications 1180 }
s350UserTrap1181 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1181."
::= { s350Notifications 1181 }
s350UserTrap1182 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1182."
::= { s350Notifications 1182 }
s350UserTrap1183 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1183."
::= { s350Notifications 1183 }
s350UserTrap1184 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1184."
::= { s350Notifications 1184 }
s350UserTrap1185 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1185."
::= { s350Notifications 1185 }
s350UserTrap1186 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1186."
::= { s350Notifications 1186 }
s350UserTrap1187 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1187."
::= { s350Notifications 1187 }
s350UserTrap1188 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1188."
::= { s350Notifications 1188 }
s350UserTrap1189 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1189."
::= { s350Notifications 1189 }
s350UserTrap1190 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1190."
::= { s350Notifications 1190 }
s350UserTrap1191 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1191."
::= { s350Notifications 1191 }
s350UserTrap1192 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1192."
::= { s350Notifications 1192 }
s350UserTrap1193 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1193."
::= { s350Notifications 1193 }
s350UserTrap1194 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1194."
::= { s350Notifications 1194 }
s350UserTrap1195 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1195."
::= { s350Notifications 1195 }
s350UserTrap1196 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1196."
::= { s350Notifications 1196 }
s350UserTrap1197 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1197."
::= { s350Notifications 1197 }
s350UserTrap1198 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1198."
::= { s350Notifications 1198 }
s350UserTrap1199 NOTIFICATION-TYPE
OBJECTS { siteName, esIndex, esName, trapEventTypeNumber,
trapEventTypeName, esIndexPoint, esPointName, esID,
clock, trapIncludedValue, trapIncludedString,
trapEventClassNumber, trapEventClassName }
STATUS current
DESCRIPTION
"This user-defined trap is issued when an event happens that causes a
trap with specific trap type 1199."
::= { s350Notifications 1199 }
END