Observium_CE/mibs/arris/CADANT-CMTS-SYSTEM-MIB

3950 lines
132 KiB
Plaintext

CADANT-CMTS-SYSTEM-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY, Counter32, Integer32, IpAddress, Unsigned32
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
TruthValue, DisplayString, MacAddress, DateAndTime, RowStatus
FROM SNMPv2-TC
InetAddressType, InetAddress, InetAddressIPv4, InetAddressIPv6
FROM INET-ADDRESS-MIB
InterfaceIndexOrZero
FROM IF-MIB
cadSystem
FROM CADANT-PRODUCTS-MIB
CardId, AdminState, ServerType, OverloadThreshold, AdminSrcAddrType
FROM CADANT-TC
BitRate
FROM DOCS-QOS3-MIB
TenthdB
FROM DOCS-IF-MIB
SnmpAdminString, SnmpEngineID
FROM SNMP-FRAMEWORK-MIB;
cadSystemMib MODULE-IDENTITY
LAST-UPDATED "201511110000Z" -- November 11, 2015
ORGANIZATION
"ARRIS Group, Inc."
CONTACT-INFO
"Arris Technical Support
Phone: +1 630 281 3000
E-Mail: support@arris.com"
DESCRIPTION
"Arris E6000 system parameters and constants"
-- REVISION "201512150000Z"
-- DESCRIPTION
-- "Add operation mode to prevent modems from using an upstream frequency beyond 42 MHz."
REVISION "201511110000Z" -- November 11, 2015
DESCRIPTION
"Add ofdmSparingCleanupOff(8) to cadSysSpOperMode"
REVISION "201511060000Z" -- November 6, 2015
DESCRIPTION
"Adjust default network packet/event rates."
REVISION "201509100000Z" -- Sept 10, 2015
DESCRIPTION
"Add upDownTrapIfDescrOff(7) to cadSysSpOperMode"
REVISION "201507210000Z" -- July 21, 2015
DESCRIPTION
"Change upper limit of cadSysLicensePorts from 1000 to 5000."
REVISION "201506030000Z" -- June 3, 2015
DESCRIPTION
"Change upper limit of cadSysLicensePorts from 256 to 1000."
REVISION "201503300000Z" -- March 30, 2015
DESCRIPTION
"Change default value of cadSysContact from support@arrisi.com to support@arris.com."
REVISION "201503050000Z" -- March 5, 2015
DESCRIPTION
"Increase the allowed IGMP throttle rate."
REVISION "201410070000Z" -- Oct 7, 2014
DESCRIPTION
"Add cadSysProcErmRpcPacketRate, cadSysProcErmRpcPacketsReceivedPassed and
cadSysProcErmRpcPacketsReceivedDropped."
REVISION "201408050000Z" -- Aug 5, 2014
DESCRIPTION
"Add cadSysAES128Enable."
REVISION "201406100000Z" -- June 10, 2014
DESCRIPTION
"Add configuration for flap list insertion."
REVISION "201405290000Z" -- May 29, 2014
DESCRIPTION
"Remove support for reduced TCS generation (i.e. remove tcsReducedOff(8) from cadSysSpOperMode)."
REVISION "201405210000Z" -- May 21, 2014
DESCRIPTION
"Changed cadSysMtceDULPacketInterval default from 30000 to 10000"
REVISION "201405140000Z" -- May 14, 2014
DESCRIPTION
"Remove cadSysModPriUsInTcsEnabled and cadSysModPriUsDbcEnabled"
REVISION "201404250000Z" -- April 25, 2014
DESCRIPTION
"Change default value of cadSysProcVrepPacketRate and cadSysProcVpmePacketRate"
REVISION "201404100000Z" -- April 10, 2014
DESCRIPTION
"Add cadSysProcVrepPacketRate, cadSysProcVpmePacketRate,
cadSysProcVrepPacketsReceivedPassed, cadSysProcVrepPacketsReceivedDropped,
cadSysProcVpmePacketsReceivedPassed and cadSysProcVpmePacketsReceivedDropped."
REVISION "201403130000Z" -- March 13, 2014
DESCRIPTION
"Add cadSysProcLacpPacketRate, cadSysProcLacpPacketsReceivedPassed and
cadSysProcLacpPacketsReceivedDropped."
REVISION "201403060000Z" -- March 6, 2014
DESCRIPTION
"Add cadSysPatchParams."
REVISION "201402210000Z" -- Feburary 21, 2014
DESCRIPTION
"Add cadSysModPriUsInTcsEnabled and cadSysModPriUsDbcEnabled"
REVISION "201401160000Z" -- January 16, 2014
DESCRIPTION
"remove rcsLoadBalOn(20) from cadSysSpOperMode."
REVISION "201311190000Z" -- November 19, 2013
DESCRIPTION
"Add operation mode for RCS load balancing control."
REVISION "201309060000Z" -- Sep 6, 2013
DESCRIPTION
"Add cadSysProcClearPolicingCounts."
REVISION "201308130000Z" -- August 13, 2013
DESCRIPTION
"Add support for LDP protocol throttling."
REVISION "201307220000Z" -- July 22, 2013
DESCRIPTION
"Add an additional reload status value for patch apply"
REVISION "201307100000Z" -- July 10, 2013
DESCRIPTION
"Removed factoryDCAMTestOff(7) from cadSysSpOperMode"
REVISION "201307010000Z" -- July 1, 2013
DESCRIPTION
"Add patch apply support."
REVISION "201306210000Z" -- June 21, 2013
DESCRIPTION
"Add support for reduced TCS generation."
REVISION "201306200000Z" -- June 20, 2013
DESCRIPTION
"Add cadSys1x1onCmAcPwrLossEnabled."
REVISION "201306190000Z" -- Jun 19, 2013
DESCRIPTION
"Add NPU Host Event throttling rate into CadSysProcPolicingConfig and related counts into CadSysProcPolicingCounts."
REVISION "201305150000Z" -- May 5, 2013
DESCRIPTION
"Add cadSysMICSecondarySecretTable."
REVISION "201301080000Z" -- January 8, 2013
DESCRIPTION
"Add patching operation support."
REVISION "201212030000Z" -- Dec 3, 2012
DESCRIPTION
"Remove fiveTapPtsOff(20) from cadSysSpOperMode."
REVISION "201211300000Z" -- Nov 30, 2012
DESCRIPTION
"Rename object names in cadLaesMdTimestampModeTable"
REVISION "201211150000Z" -- Oct 15, 2012
DESCRIPTION
"Add loadBalUnbondedVoipOn(6) and factoryDCAMTestOff(7) to cadSysSpOperMode"
REVISION "201210040000Z" -- Oct 4, 2012
DESCRIPTION
"Remove cadSysDownChannelAnnex"
REVISION "201210010000Z" -- Oct 1, 2012
DESCRIPTION
"Add cadLaesMdTimestampModeTable"
REVISION "201206150000Z" -- June 15, 2012
DESCRIPTION
"remove CadSysSourceInterface table and
remove cadSnmpSourceIpAddrType and
cadSnmpSourceIpAddr"
REVISION "201203220000Z" -- Mar 22, 2012
DESCRIPTION
"Add port licensing control."
REVISION "201203040000Z" -- Mar 4, 2012
DESCRIPTION
"Add new reload status values for standby firmware upgrade and standby write mem."
REVISION "201202230000Z" -- Feb 23, 2012
DESCRIPTION
"Add cadSysSourceAddressTable"
REVISION "201202080000Z" -- February 9, 2012
DESCRIPTION
"Add support for enhanced SNR with new TAPs."
REVISION "201201180000Z" -- Jan 18, 2012
DESCRIPTION
"Add new reload status value for image copy."
REVISION "201112130000Z" -- Dec 13, 2011
DESCRIPTION
"Add new reload status value."
REVISION "201111170000Z" -- Nov 17, 2011
DESCRIPTION
"Add new reload status values."
REVISION "201111080000Z" -- Nov 8, 2011
DESCRIPTION
"Removed upstreamLockupIgnore and upstreamLockupDetectLong.
Add support for maintenance lockup detection configuration."
REVISION "201111040000Z" -- Nov 4, 2011
DESCRIPTION
"Remove the following MIB objects:
cadSysProcScmGlobalPacketRate ,cadSysProcScmGlobalPacketsReceivedPassed,
cadSysProcScmGlobalPacketsReceivedDropped,cadSysProcOspfv3PacketsSent,
cadSysProcTftpIpv6PacketsSent,cadSysProcRouterControlGlobalPacketsSent,
cadSysProcArpPacketsSent, cadSysProcDhcpPacketsSent,
cadSysProcIcmpPacketsSent, cadSysProcOspfPacketsSent,
cadSysProcRipPacketsSent, cadSysProcIgmpPacketsSent,
cadSysProcRouterControlOtherPacketsSent, cadSysProcSnmpPacketsSent,
cadSysProcTftpPacketsSent, cadSysProcIsisPacketsSent,
cadSysProcScmGlobalPacketsSent, cadSysProcNdPacketsSent,
cadSysProcDhcpIpv6PacketsSent, cadSysProcIcmpIpv6PacketsSent,
cadSysProcMldPacketsSent, cadSysProcBgpPacketsSent,
cadSysProcPimPacketsSent, cadSysProcSnmpCmPacketsSent,
cadSysProcCopsPacketsSent, and cadSysProcTelnetPacketsSent."
REVISION "201107080000Z" -- July 8, 2011
DESCRIPTION
"Add support for maintenance control of fan speed."
REVISION "201105220000Z" -- May 22, 2011
DESCRIPTION
"Add support for maintenance overload configuration."
REVISION "201104050000Z" -- Apr 5, 2011
DESCRIPTION
"Modified allowed values of cadSysReloadStatus."
REVISION "201103030000Z" -- March 3, 2011
DESCRIPTION
"Add cadSysTftpProxy
cadSysProcTftpIpv6PacketRate
cadSysProcTftpIpv6PacketsReceivedPassed
cadSysProcTftpIpv6PacketsReceivedDropped
cadSysProcTftpIpv6PacketsSent"
REVISION "201102230000Z" -- Feb 23, 2011
DESCRIPTION
"Add cpeNacksForceCmReset bit back to cadSysSpOperMode"
REVISION "201012220000Z" -- Dec 22, 2010
DESCRIPTION
"Change cadSysDataServerSnmpRefreshTime to be in seconds"
REVISION "201012100000Z" -- Dec 10, 2010
DESCRIPTION
"Deprecated upstreamLockupIgnore and upstreamLockupDetectLong
and cadSysModemLossThreshold"
REVISION "201012010000Z" -- Dec 1, 2010
DESCRIPTION
"Add cadSysSnmpReadAheadMax and cadSysSnmpRefreshTime"
REVISION "201011180000Z" -- Nov 18, 2010
DESCRIPTION
"Add cadSysMacMoveBlockedOnRcptDhcpPkt"
REVISION "201009220000Z" -- Sep 22, 2010
DESCRIPTION
"Add support for DataServer variables."
REVISION "201009150000Z" -- Sep 15, 2010
DESCRIPTION
"Add pending(3), and none(4) to cadSysXDLicKeyStatus"
REVISION "201009020000Z" -- Sep 2, 2010
DESCRIPTION
"Add cadSysUnicastNpUsAcquisition"
REVISION "201007310000Z" -- July 31, 2010
DESCRIPTION
"Add support for OSPFv3 counts."
REVISION "201007210000Z" -- July 21, 2010
DESCRIPTION
"Remove cadSysAttrFlowAssignStrictEnforcement"
REVISION "201007120000Z" -- July 12, 2010
DESCRIPTION
"Add cadSysAttrFlowAssignStrictEnforcement"
REVISION "201003150000Z" -- Mar 15, 2010
DESCRIPTION
"Add cadSysAllowAmbiguityOverride"
REVISION "201002230000Z" -- Feb 23, 2010
DESCRIPTION
"Deprecate cadSysControlGroup"
REVISION "201002110000Z" -- Feb 11, 2010
DESCRIPTION
"Add reloadWritemem and reloadEraseMem to cadSysReloadOperation
and eraseMem and remoteEraseMem to cadSysReloadStatus"
REVISION "201001080000Z" -- Jan 8, 2010
DESCRIPTION
"Add cadSysPeakTrRateUpstream and cadCosUpPeakTrafficRate for Upstream
Power Boot feature. Make cadSysPeakTrafRateFor11CMs obsolete"
REVISION "200910080000Z" -- Oct 8, 2009
DESCRIPTION
"change default value of cadSysDelayedCpeLearning from false(2) to true(1)"
REVISION "200909220000Z" -- Sep 22, 2009
DESCRIPTION
"chagne default value of cadSysProcNdPacketRate from 1000 to 700"
REVISION "200909140000Z" -- Sep 14, 2009
DESCRIPTION
"Add cadSysSendTccRefIdPerFragment"
REVISION "200908170000Z" -- Aug 17, 2009
DESCRIPTION
"Add cadSysModPriDsInRccEnabled"
REVISION "200905040000Z" -- May 4, 2009
DESCRIPTION
"Add new cadSysSpOperMode use16ForDSPeakTrafficRate"
REVISION "200904220000Z" -- Apr 22, 2009
DESCRIPTION
"Added cadSysSourceIpAddrCableIntercept, cadSysSourceInterfaceCableIntercept
and cadSnmpSourceIpAddrTypeCableIntercept."
REVISION "200901230000Z" -- Jan 23, 2009
DESCRIPTION
"Added cadSysDelayedCpeLearning."
REVISION "200812180000Z" -- December 18, 2008
DESCRIPTION
"cadSysProcArpPacketRate default value changed from 2500 to 700"
REVISION "200812080000Z" -- December 8, 2008
DESCRIPTION
"Add cadMtcmConditionalOverride."
REVISION "200810220000Z" -- October 22, 2008
DESCRIPTION
"Add cadSysLO1LeakDetect control for DMM LO1 spurs."
REVISION "200809240000Z" -- Sep 24, 2008
DESCRIPTION
"Add cadSysProcCopsPacketRate and cadSysProcTelnetPacketRate."
REVISION "200809150000Z" -- Sep 15, 2008
DESCRIPTION
"Change default value of cadSysProcSnmpPacketRate from 100 to 650."
REVISION "200808280000Z" -- Aug 28, 2008
DESCRIPTION
"Add cadSysMaxUcdBurstLength."
REVISION "200803170000Z" -- March 17, 2008
DESCRIPTION
"Add oper mode bit for policy TLV and protocol throttling for IPV6."
REVISION "200802190000Z" -- Feb 19, 2008
DESCRIPTION
"Modified allowed values of cadSysReloadStatus."
REVISION "200802040000Z" -- Feb 4, 2008
DESCRIPTION
"Added cadSysDownChannelAnnex. Annex is configured per CMTS bassis."
REVISION "200712020000Z" -- December 2, 2007
DESCRIPTION
"Added additional reload support"
REVISION "200611090000Z" -- November 9, 2006
DESCRIPTION
"Add oneDCmDSMaxTrafBurstOn to operation mode."
REVISION "200608290000Z" -- August 29, 2006
DESCRIPTION
"Add cadSysSourceInterfaceRemoteQuery to cadSysSourceInterface Object."
REVISION "200608100000Z" -- August 10, 2006
DESCRIPTION
"Add bpiHybridOff to cadSysSpOperMode object."
REVISION "200607120000Z"
DESCRIPTION
"Added SNMP remote engine support."
REVISION "200602220000Z"
DESCRIPTION
"Removed cpeNacksForceCmReset bit from cadSysSpOperMode"
REVISION "200601250000Z"
DESCRIPTION
"Added upstreamLockupDetectLong BIT to cadSysSpOperMode for longer upstream lockup detect sampling period."
REVISION "200601120000Z"
DESCRIPTION
"Added cadSysMtceParams for maintenance intervals and scheduling."
REVISION "200601030000Z"
DESCRIPTION
"Added cadSysCpeHostAuthorization for CPE Host Authorization (Motorola Style Anti-Spoofing) feature."
REVISION "200509230000Z"
DESCRIPTION
"Added cadSnmpSourceIp for Legal Intercept feature."
REVISION "200509210000Z"
DESCRIPTION
"Add support for suppressing downstream priority channel mapping
add support for virtual modems."
REVISION "200508300000Z"
DESCRIPTION
"Add support for disabling downstream override and supressing DCDs."
REVISION "200508240000Z"
DESCRIPTION
"Added cadSysPeakTrafRateFor11CMs."
REVISION "200508080000Z"
DESCRIPTION
"Add support for DOCSIS 1.0+"
REVISION "200507110000Z"
DESCRIPTION
"Added cadCosDnPeakTrafficRate for Traffic Shaping for 2D12U feature."
REVISION "200506200000Z"
DESCRIPTION
"Renamed showCmFormatCV bit to showCmFormatCVOff and flipped the semantics"
REVISION "200506080000Z"
DESCRIPTION
"Added SCM Global counts"
REVISION "200505180000Z"
DESCRIPTION
"Added bpiDynamicMulticastOff bit to cadSysSpOperMode"
REVISION "200504210000Z"
DESCRIPTION
"Added showCmFormatCV bit to cadSysSpOperMode"
REVISION "200504140000Z"
DESCRIPTION
"Merge with 4.6"
REVISION "200503010000Z"
DESCRIPTION
"Remove obsolete error recovery bits"
REVISION "200501060000Z"
DESCRIPTION
"Included support for Source Interface for SNMP Traps."
REVISION "200412030000Z"
DESCRIPTION
"Included support for TFTP Enforce feature."
REVISION "200410120000Z"
DESCRIPTION
"Included support for SNMP policing on the FCM."
REVISION "200409220000Z"
DESCRIPTION
"Included cadSysTcpSmoothingValue1D8U and cadSysTcpSmoothingValue2D12U in the cadSysParamsGroup."
REVISION "200404300000Z"
DESCRIPTION
"Added IS-IS counts."
REVISION "200404130000Z"
DESCRIPTION
"Included cadSysRemoteFSEnable and cadSysRemotePortEnable in the cadSysParamsGroup."
REVISION "200403230000Z"
DESCRIPTION
"Added cadSysRemoteFSEnable and cadSysRemotePortEnable for allowing
the active SCM to access filesystems and ports of the standby SCM."
REVISION "200402230000Z"
DESCRIPTION
"Added cadSysFlaplistPowerAdjustThreshold for FlapManager enhancement."
REVISION "200402200000Z"
DESCRIPTION
"Add automatic fan control switch to sysparams."
REVISION "200312050000Z"
DESCRIPTION
"Change default FCM other protocol policing rate for BGP."
REVISION "200310280000Z"
DESCRIPTION
"Removed mapgbdiff, mapgbsm1, mapgbsm2, ptcspec, and preeq10 from cadSysSpOperMode object."
REVISION "200310210000Z"
DESCRIPTION
"Changed cadCosToQosMapping scalar object to a table."
REVISION "200310200000Z"
DESCRIPTION
"Changed bootparams to rw."
REVISION "200308260000Z"
DESCRIPTION
"Added default maximum traffic burst for 1.1 CMs."
REVISION "200308250000Z"
DESCRIPTION
"Added percent additional downstream bandwidth allocated for dynamic service flows."
REVISION "200308180000Z"
DESCRIPTION
"Change default FCM policing default rates"
REVISION "200308060000Z"
DESCRIPTION
"Added upce bit to cadSysSpOperMode"
REVISION "200306160000Z"
DESCRIPTION
"Added cpeNacksForceCmReset bit to cadSysSpOperMode"
REVISION "200305230000Z"
DESCRIPTION
"Changed default of cadSysMaxQoSActiveTimeout from 0 to 30"
REVISION "200305080000Z"
DESCRIPTION
"Add server enable/disable support."
REVISION "200304300000Z"
DESCRIPTION
"Add both front panel addresses to bootparams."
REVISION "200304200000Z"
DESCRIPTION
"Changed maximum size of MIC authstring to 64 bytes."
REVISION "200304140000Z"
DESCRIPTION
"Added cmstatusoperational bit to cadSysSpOperMode object."
REVISION "200303200000Z"
DESCRIPTION
"Added ability to provision whether a CM in 1.0 can use concat and/or frag"
REVISION "200303140000Z"
DESCRIPTION
"Added maximum allowed QoS Active and Admitted Timeout values"
REVISION "200303070000Z"
DESCRIPTION
"Change length of MIC auth string"
REVISION "200302140000Z"
DESCRIPTION
"Added tables to support banner related objects.
Change encoding of MIC auth string"
REVISION "200212120000Z"
DESCRIPTION
"Removed special operating mode for preeq."
REVISION "200211220000Z"
DESCRIPTION
"Added control object for erasing NVRAM."
REVISION "200211200000Z"
DESCRIPTION
"Add processor protocol policing objects."
REVISION "200210040000Z"
DESCRIPTION
"Added special operating mode for preeq."
REVISION "200210030000Z"
DESCRIPTION
"Changed cadCosUpMaxTrafficBurst from 1522 to 3044, per RFI-N-02091."
REVISION "200207020000Z"
DESCRIPTION
"Changed cadSysCMConfiguration to read-write."
REVISION "200204250000Z"
DESCRIPTION
"Add key chain objects."
REVISION "200204230000Z"
DESCRIPTION
"Add enbudptcpfltr bit to cadSysSpOperMode object."
REVISION "200204220000Z"
DESCRIPTION
"Add global counts collection rate object."
REVISION "200204020001Z"
DESCRIPTION
"Add cadSysSpOperMode object."
REVISION "200204020000Z"
DESCRIPTION
"Add cosToQosMapping group."
REVISION "200201150000Z"
DESCRIPTION
"Add configuration save time."
REVISION "200111070000Z"
DESCRIPTION
"Add floating IP address and remove NAM support."
REVISION "200108180000Z"
DESCRIPTION
"Add system table dictionary."
REVISION "200107180000Z"
DESCRIPTION
"Add enable/disable for Mcard ports."
::= { cadSystem 1 }
--=========== System Objects ==============================
cadSysParams OBJECT IDENTIFIER ::= { cadSystemMib 1 }
cadSysSystem OBJECT IDENTIFIER ::= { cadSystemMib 2 }
cadSysControl OBJECT IDENTIFIER ::= { cadSystemMib 3 }
cadSysSnmp OBJECT IDENTIFIER ::= { cadSystemMib 4 }
cadSysBootParams OBJECT IDENTIFIER ::= { cadSystemMib 5 }
cadSysReload OBJECT IDENTIFIER ::= { cadSystemMib 6 }
cadSysImage OBJECT IDENTIFIER ::= { cadSystemMib 7 }
cadSysDictionary OBJECT IDENTIFIER ::= { cadSystemMib 8 }
cadSysConfiguration OBJECT IDENTIFIER ::= { cadSystemMib 9 }
cadCosToQosMapping OBJECT IDENTIFIER ::= { cadSystemMib 10 }
cadSysKeyChain OBJECT IDENTIFIER ::= { cadSystemMib 11 }
cadSysProcPolicingConfig OBJECT IDENTIFIER ::= { cadSystemMib 13 }
cadSysProcPolicingCounts OBJECT IDENTIFIER ::= { cadSystemMib 14 }
cadSysBanner OBJECT IDENTIFIER ::= { cadSystemMib 15 }
cadSysServer OBJECT IDENTIFIER ::= { cadSystemMib 16 }
cadSysPatchParams OBJECT IDENTIFIER ::= { cadSystemMib 17 }
cadSysMtceParams OBJECT IDENTIFIER ::= { cadSystemMib 19 }
cadSysDataServer OBJECT IDENTIFIER ::= { cadSystemMib 21 }
cadSysSourceAddress OBJECT IDENTIFIER ::= { cadSystemMib 22 }
cadSysLicenseControl OBJECT IDENTIFIER ::= { cadSystemMib 23 }
cadLaesMdTimestampMode OBJECT IDENTIFIER ::= { cadSystemMib 24 }
cadSysSharedSecret OBJECT IDENTIFIER ::= { cadSystemMib 25 }
--=========== Params Objects ==============================
cadSysSyncInterval OBJECT-TYPE
SYNTAX Integer32 (0..200)
UNITS "Milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Nominal time between transmission of SYNC messages. (ref 6.3.2)"
::= { cadSysParams 1 }
cadSysUCDInterval OBJECT-TYPE
SYNTAX Integer32 (0..2000)
UNITS "Milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time between transmission of UCD messages. (ref 6.3.3)"
::= { cadSysParams 2 }
cadSysMaxMAPPending OBJECT-TYPE
SYNTAX Integer32 (0..4096)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of mini-slots that a CMTS is allowed to map
into the future. (ref 6.3.4)"
::= { cadSysParams 3 }
cadSysRangingInterval OBJECT-TYPE
SYNTAX Integer32 (0..2000)
UNITS "Milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time between transmission of broadcast Ranging requests. (ref 7.3.3)"
::= { cadSysParams 4 }
cadSysInvitedRangingRetries OBJECT-TYPE
SYNTAX Integer32 (16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of retries on inviting ranging requests. (ref 9.2.4)"
::= { cadSysParams 5 }
cadSysRegistrationRequestRetries OBJECT-TYPE
SYNTAX Integer32 (3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of retries on registration requests/responses."
::= { cadSysParams 6 }
cadSysCMMAPProcessingTime OBJECT-TYPE
SYNTAX Integer32 (200..2000)
UNITS "Microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time provided between arrival of the last bit of a MAP
at a CM and effectiveness of that MAP. (ref 7.1.1)"
::= { cadSysParams 7 }
cadSysCMRangingResponseProcessingTime OBJECT-TYPE
SYNTAX Integer32 (1..200)
UNITS "Milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum tile allowed fro a CM following receipt of a rangin
response before it is expected to reply to an invited ranging
request."
::= { cadSysParams 8 }
cadSysCMConfiguration OBJECT-TYPE
SYNTAX Integer32 (30..2000)
UNITS "Seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum time allowed for a CM, following receipt of a
configuration file, to send a Registration Request to a CMTS."
DEFVAL { 30 }
::= { cadSysParams 9 }
cadSysT5Timeout OBJECT-TYPE
SYNTAX Integer32 (0..2000)
UNITS "Milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wait for Upstream CHannel Change response."
::= { cadSysParams 10 }
cadSysT6Timeout OBJECT-TYPE
SYNTAX Integer32 (0..3000)
UNITS "Milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wait for REG-RSP and REG-ACK"
::= { cadSysParams 11 }
cadSysMiniSlotSize OBJECT-TYPE
SYNTAX Integer32 (32..300)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Size of mini-slotfor upstream transmission. Must be a
power of 2 (in units of the Timebase Tick)."
::= { cadSysParams 12 }
cadSysDSxRequestRetries OBJECT-TYPE
SYNTAX Integer32 (3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Timeout Retries on DSA/DSC/DSD Requests."
::= { cadSysParams 13 }
cadSysDSxResponseRetries OBJECT-TYPE
SYNTAX Integer32 (3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Timeout Retries on DSA/DSC/DSD Responses."
::= { cadSysParams 14 }
cadSysT7Timeout OBJECT-TYPE
SYNTAX Integer32 (0..1000)
UNITS "Milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wait for DSA/DSC/DSD Response timeout."
::= { cadSysParams 15 }
cadSysT8Timeout OBJECT-TYPE
SYNTAX Integer32 (0..300)
UNITS "Milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wait for DSA/DSC/DSD Acknowledge timeout."
::= { cadSysParams 16 }
cadSysT9Timeout OBJECT-TYPE
SYNTAX Integer32 (15..1500)
UNITS "Minutes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Registration timeout, the time allowed between the CMTS
sending a RNG-RSP(success) to a CM, and receiving a
REG-REQ from that same CM."
::= { cadSysParams 17 }
cadSysT10Timeout OBJECT-TYPE
SYNTAX Integer32 (0..3000)
UNITS "Milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wait for Transaction End timeout."
::= { cadSysParams 18 }
cadSysT11Timeout OBJECT-TYPE
SYNTAX Integer32 (0..300)
UNITS "Milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wait for a DCC Response on the old channel."
::= { cadSysParams 19 }
cadSysT13Timeout OBJECT-TYPE
SYNTAX Integer32 (0..1000)
UNITS "Milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum holding time for QOS resources for DCC."
::= { cadSysParams 20 }
cadSysDCCREQRetries OBJECT-TYPE
SYNTAX Integer32 (3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of retries on Dynamic Channel Change Request."
::= { cadSysParams 21 }
cadSysMICEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable MIC checking on the CMTS."
::= { cadSysParams 22 }
cadSysMICAuthString OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Encrypted MIC Authentication"
::= { cadSysParams 23 }
cadSysAutoRecoveryEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable automatic recovery of card/port/software in case
of component failure."
DEFVAL { true }
::= { cadSysParams 24 }
cadSysActiveIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ip Address of the active control complex."
DEFVAL { '00000000'h }
::= { cadSysParams 25 }
cadSysSpOperMode OBJECT-TYPE
SYNTAX BITS {
dqossf10cms(0),
adjrxpwrctl(1),
enbudptcpfltr(2),
upce(3),
use16ForDSPeakTrafficRate(4),
cpeNacksForceCmReset(5),
loadBalUnbondedVoipOn(6),
upDownTrapIfDescrOff(7),
ofdmSparingCleanupOff(8),
limitUsRngRspFreqOff(9),
reserved10(10),
cmstatusoperational(11),
reserved12(12),
docsis20test(13),
reserved14(14),
reserved15(15),
reserved16(16),
reserved17(17),
reserved18(18),
reserved19(19),
reserved20(20),
showCmFormatCVOff(21),
bpiDynamicMulticastOff(22),
docsis10plusOff(23),
downstreamOverrideOn(24),
supressDCDOff(25),
virtualCmOff(26),
bpiHybridOff(27),
oneDCmDSMaxTrafBurstOn(28),
docsis30ReqTxPolicyChkOff(29),
reserved30(30),
reserved31(31)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Special operational mode. Value of 1 indicates the mode is enabled.
dqossf10cms - Allow 1.0 CMs to be stored in DocsQosServiceFlowEntry
adjrxpwrctl - Allow rx power control to be adjusted by mod type usage
enbudptcpfltr - Allow combining of Udp and Tcp messages in a single filter
upce - Allow Upstream Packet Classifier Enforcement
use16ForDSPeakTrafficRate - use the defunct TLV type 16 for DS peak traffic rate
cpeNacksForceCmReset - - Force CM reset upon receiving 3 consecutive CPE NACKs
loadBalUnbondedVoipOn - Allow load balancing for non-bonded voice calls
limitUsRngRspFreqOff - Prevent CM from using an upstream frequency beyond 42 MHz
upDownTrapIfDescrOff - Allow linkup or linkdown trap to include ifDescr
ofdmSparingCleanupOff - Allow automatically reset any D3.1 CMs in a cable-mac that
has an OFDM channel on that DCAM in the CM's RCS after a
failover or fallback
cmstatusoperational - Support DOCS-IF-MIB draft-05 (cw26)'s change to
docsIfCmtsCmStatusValue, such that online modems take on a value of
operational(8) at the CMTS. If disabled, operational(8) is not used and
online modems take on a value of registrationComplete(6) at the CMTS.
docsis20test - Allow running of DOCSIS 2.0 Tests.
showCmFormatCVOff - show cable modem is formatted per CableVision's requirements if set to 0.
docsis10plusOff - DOCSIS 1.0+ support is enabled if set to 0.
downstreamOverrideOn - downstream overrides are disabled if this is set to 0.
supressDCDOff - DCDs are suppressed if set to 0.
virtualCmOff - support for virtual modems is enabled if set to 0.
bpiHybridOff - Allow DOCSIS 1.1 modems to operate in BPI instead of BPI+ if this is set to 0.
oneDCmDSMaxTrafBurstOn - Override Max Traffic Burst for DOCSIS 1.1 modems on a 1D CAM with E6000 setting if this is set to 0.
docsis30ReqTxPolicyChkOff - Override DOCSIS 3.0 checking for Request/Transmission Policy TLV on upstream flows.
"
DEFVAL { { dqossf10cms, adjrxpwrctl, enbudptcpfltr, use16ForDSPeakTrafficRate, cpeNacksForceCmReset,
loadBalUnbondedVoipOn, upDownTrapIfDescrOff, ofdmSparingCleanupOff, limitUsRngRspFreqOff, reserved10,
cmstatusoperational, reserved12, reserved14,
reserved15, reserved16, reserved17,
reserved18, reserved19, reserved20, showCmFormatCVOff, bpiDynamicMulticastOff,
docsis10plusOff, downstreamOverrideOn, supressDCDOff, virtualCmOff, bpiHybridOff,
oneDCmDSMaxTrafBurstOn, docsis30ReqTxPolicyChkOff, reserved30, reserved31
} } -- upce and docsis20test disabled and use16ForDSPeakTrafficRate by default
::= { cadSysParams 26 }
cadSysCountsCollectionRate OBJECT-TYPE
SYNTAX Unsigned32 (0|15..1440) -- disabled or from 15 minutes to 24 hours
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The period, in minutes, in which every count in the CMTS
is to be collected. If this object is set to 0, counts
collection will be disabled."
DEFVAL { 120 } -- 2 hours
::= { cadSysParams 27 }
cadSysMaxQoSActiveTimeout OBJECT-TYPE
SYNTAX Integer32 (0..65535)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the maximum QoS Active Timeout the E6000 is willing to allow. If
a larger value is received in a CM request the E6000 will return this value
instead in the response (Reference DOCSIS RFI Section c.2.2.5.6). Note a
value of 0 is infinite and is therefore treated as the largest value in the
range."
DEFVAL { 30 }
::= { cadSysParams 28 }
cadSysMaxQoSAdmittedTimeout OBJECT-TYPE
SYNTAX Integer32 (0..65535)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the maximum QoS Admitted Timeout the E6000 is willing to allow. If
a larger value is received in a CM request the E6000 will return this value
instead in the response (Reference DOCSIS RFI Section c.2.2.5.7). Note a
value of 0 is infinite and is therefore treated as the largest value in the
range."
DEFVAL { 200 }
::= { cadSysParams 29 }
cadSysAllow10CmConcatenation OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines whether or not the E6000 will allow a modem operating in DOCSIS 1.0
mode to utilize concatenation. If this value is false and a modem operating
in 1.0 mode sends up a modem capability indicating concatenation the E6000 will
respond by turning that capability off. If this value is true the modem will
be returned whatever it requests (on or off)."
DEFVAL { false }
::= { cadSysParams 30 }
cadSysAllow10CmFragmentation OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines whether or not the E6000 will allow a modem operating in DOCSIS 1.0
mode to utilize fragmentation. If this value is false and a modem operating
in 1.0 mode sends up a modem capability indicating fragmentation the E6000 will
respond by turning that capability off. If this value is true the modem will
be returned whatever it requests (on or off)."
DEFVAL { true }
::= { cadSysParams 31 }
cadSysPercentAddtlDsBwAllocated OBJECT-TYPE
SYNTAX Integer32 (0..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value of this setting is used to make a percentage increase to a dynamic
downstream service flows maximum traffic rate. This is flexiblity actually
causes the E6000 to operate outside the DOCSIS 1.1 specification by allocating and
allowing more traffic than was actually requested. The initial reason for
providing this capability is to mask problems produced in the Voice environment
where devices have been seen to violate the traffic rates. Examples of this are
MTAs that overuse the QI bit for long durations thus overdriving the downstream
burst interval and the Neura IPDT gateway introducing an additional 0.5% inband
signaling to the DS voice flow"
DEFVAL { 1 }
::= { cadSysParams 32 }
cadSysMaxTrafBurstFor11CMs OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the default value that will be used to populate the Maximum Traffic Burst
for a 1.1 modem unless the maximum traffic burst TLV is explicitly provided in either
the modems Request or in a Service Class Name definition. This value is being made
programmable for 2 reasons: 1) So that it can be set to the DOCSIS default of 3044 for
CableLabs testing and 2) it can be tuned for real world applications."
DEFVAL { 128000 }
::= { cadSysParams 33 }
cadSysFanSpeedControlEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Enable automatic fan speed control. "
DEFVAL { false }
::= { cadSysParams 34 }
cadSysFlaplistPowerAdjustThreshold OBJECT-TYPE
SYNTAX TenthdB (0|10..100)
UNITS "dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold is used to monitor the power adjust in the flap
list. For a range request received that results in a power adjust
exceeding the threshold value will cause the counter
cadIfCmtsCmCountsPowerAdjExceedsThreshold to be incremented.
If the threshold is set to 0, the monitoring of power adjustment
in the flap list is disabled."
DEFVAL { 30 }
::= { cadSysParams 35 }
cadSysRemoteFSEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the active SCM should allow mounting the
the filesystems of the standby SCM."
DEFVAL { true }
::= { cadSysParams 36 }
cadSysRemotePortEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the active SCM should allow redirection of
the serial console of the standby SCM."
DEFVAL { true }
::= { cadSysParams 37 }
cadSysTcpSmoothingValue1D8U OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TCP smoothing value to be programmed into hardware on 1D8U CAMs."
DEFVAL { 0 }
::= { cadSysParams 38 }
cadSysTcpSmoothingValue2D12U OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TCP smoothing value to be programmed into hardware on 2D12U CAMs."
DEFVAL { 0 }
::= { cadSysParams 39 }
cadSysModemLossThreshold OBJECT-TYPE
SYNTAX Unsigned32 (10..2000)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Minimum modem threshold triggering detection of an
upstream channel lockup."
DEFVAL { 10 }
::= { cadSysParams 40 }
cadSysPeakTrafRateFor11CMs OBJECT-TYPE
SYNTAX BitRate
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"This is the default value that will be used to populate the Peak Traffic Rate
for a 1.1 modem configuration file unless the peak traffic rate is explicitly
provided by a Service Class Name definition."
DEFVAL { 0 }
::= { cadSysParams 41 }
cadSysCpeHostAuthorization OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable enables the CPE Host Authorization feature."
DEFVAL { false }
::= { cadSysParams 44 }
cadSysMaxUcdBurstLength OBJECT-TYPE
SYNTAX Integer32(2048..16128)
UNITS "bytes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable limits the maximum UCD burst length."
DEFVAL { 16128 }
::= { cadSysParams 46 }
cadSysLO1LeakDetect OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable controls LO1 leak detection on the DMM."
DEFVAL { false }
::= { cadSysParams 47 }
cadMtcmConditionalOverride OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If set to 'true', for a MAC Domain configured for MTCM enabled operation,
the E6000 will set a registering MTCM-capable CM to be MTCM disabled (via REG-RSP message)
unless at least one of the config file's service flows was specifically configured
to have the Bonded bit set in the Required attribute mask
(in which case the CM will be set to MTCM enabled).
If set to false, standard DOCSIS 3.0 operation will result."
DEFVAL { false }
::= { cadSysParams 48 }
cadSysDelayedCpeLearning OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This setting only applies to modems that have BPI enabled.
When set to false(2), CPE learning is enabled during registration
when BPI initialization is initiated for those modems using BPI.
When set to true(1), CPE learning is delayed during registration
until BPI initialization is complete for those modems using BPI.
For modems not using BPI, CPE learning is enabled when registration is complete."
DEFVAL { true }
::= { cadSysParams 49 }
cadSysModPriDsInRccEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable modifying primary Downstream channel in RCC of Reg-Rsp-MP.
Refer ECN 690."
DEFVAL { false }
::= { cadSysParams 52 }
cadSysSendTccRefIdPerFragment OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Settings for sending the Transmit Channel Configuration (TCC) Reference sub-type 46.1 for type 46 TCC fragmentation.
If 'true', sends 46.1 Ref ID in every type 46 TCC fragment;
If 'false', only sends 46.1 Ref ID in the first TCC fragment (DOCSIS Compliant)."
DEFVAL { true }
::= { cadSysParams 53 }
cadSysPeakTrRateUpstream OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables support for Peak Traffic Rate in the upstream direction."
DEFVAL { false }
::= { cadSysParams 54 }
cadSysAllowAmbiguityOverride OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables ambiguity resolution channel-override actions."
DEFVAL { false }
::= { cadSysParams 55 }
cadSysUnicastNpUsAcquisition OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables unicast non-primary upstream channel acquisition."
DEFVAL { false }
::= { cadSysParams 56}
cadSysMacMoveBlockedOnRcptDhcpPkt OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"MAC movement is blocked on receipt of DHCP packets"
DEFVAL { true }
::= { cadSysParams 57 }
cadSysTftpProxy OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1),
ipv4only(2),
ipv6only(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter provides a global enable for the TFTP
Enforce and Dynamic Shared Secret features. In order for
the cadIfMacDomainTftpEnforce and cadIfMacDomainDynamicSecret
parameters to take effect, this parameter must also be enabled.
This parameter can also limit those features to only IPv4
transfers or IPv6 transfers."
DEFVAL { enable }
::= { cadSysParams 58 }
cadSysFanSpeedLevel OBJECT-TYPE
SYNTAX Integer32(0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the fan speed for the chassis."
DEFVAL { 0 }
::= { cadSysParams 59 }
cadSys1x1onCmAcPwrLossEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables/disables the CMTS reaction to a AC Power Loss CM-STATUS.
If true, the CMTS will wait until cadSys1x1onCmAcPwrLossHoldoff expires, and then
the CMTS will place the CM into a 1x1 (US/DS) channel mode to conserve CM battery power.
If false, the CMTS will not place a CM that reports an AC Power Loss into 1x1 mode."
DEFVAL { false }
::= { cadSysParams 60 }
cadSysFlapListInsertionThreshold OBJECT-TYPE
SYNTAX Integer32 (60..86400)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object shows the number of seconds between successive ranging
attempts that must pass before the modem is counted as flapped.
The modem must have also been in a provisioning or registered state
before the ranging request."
DEFVAL { 180 }
::= { cadSysParams 61 }
cadSysAES128Enable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables AES-128 Cryptography Suite for BPI+ when true."
DEFVAL { false }
::= { cadSysParams 62 }
--=========== System Objects ==============================
cadSysContact OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The textual identification of the contact person for this
managed node, together with information on how to contact
this person. If no contact information is known, the value
is the zero-length string."
DEFVAL { "support@arris.com" }
::= { cadSysSystem 1 }
cadSysName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An administratively-assigned name for this managed node.
By convention, this is the node's fully-qualified domain
name. If the name is unknown, the value is the zero-length
string."
::= { cadSysSystem 2 }
cadSysLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The physical location of this node (e.g., `telephone
closet, 3rd floor'). If the location is unknown, the value
is the zero-length string."
DEFVAL { "" }
::= { cadSysSystem 3 }
--=========== Control Objects =============================
cadSysWriteMem OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable always returns FALSE upon reading. When
set to TRUE, the configuration data currently resident
in volatile memory (RAM) is written to persistent memory (NVRAM)."
DEFVAL { false }
::= { cadSysControl 1 }
cadSysEraseMem OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable always returns FALSE upon reading. When
set to TRUE, the configuration data currently resident
in persistent memory (NVRAM) is erased."
DEFVAL { false }
::= { cadSysControl 2 }
--=========== SNMP Objects =============================
cadSysEnableAuthenTraps OBJECT-TYPE
SYNTAX INTEGER { enable(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the SNMP entity is permitted to generate
authentication traps."
::= { cadSysSnmp 1 }
cadSysSnmpReadAheadMax OBJECT-TYPE
SYNTAX Unsigned32 (0..20)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value is the maximum number of records to read ahead"
DEFVAL { 0 }
::= { cadSysSnmp 2 }
cadSysSnmpRefreshTime OBJECT-TYPE
SYNTAX Unsigned32 (0..1200)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value represents how old a database record can be to be used."
DEFVAL { 0 }
::= { cadSysSnmp 3 }
cadSnmpRemoteEngineTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadSnmpRemoteEngineEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Table containing information of remote SNMP engines."
::= { cadSysSnmp 4 }
cadSnmpRemoteEngineEntry OBJECT-TYPE
SYNTAX CadSnmpRemoteEngineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry containing information of remote SNMP engines."
INDEX { cadSnmpRemoteEngineIpAddress, cadSnmpRemoteEnginePortNumber }
::= { cadSnmpRemoteEngineTable 1 }
CadSnmpRemoteEngineEntry ::= SEQUENCE {
cadSnmpRemoteEngineIpAddress IpAddress,
cadSnmpRemoteEnginePortNumber Integer32,
cadSnmpRemoteEngineID SnmpEngineID,
cadSnmpRemoteUserName SnmpAdminString,
cadSnmpRemoteEngineType INTEGER,
cadSnmpRemoteEngineStatus RowStatus
}
cadSnmpRemoteEngineIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The IP address of a remote SNMP engine with which this user can communicate."
::= { cadSnmpRemoteEngineEntry 1 }
cadSnmpRemoteEnginePortNumber OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The UDP port of a remote SNMP engine with which this user can communicate."
::= { cadSnmpRemoteEngineEntry 2 }
cadSnmpRemoteEngineID OBJECT-TYPE
SYNTAX SnmpEngineID
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"An SNMP engine's administratively-unique identifier of a remote
SNMP engine with which this user can communicate."
::= { cadSnmpRemoteEngineEntry 3 }
cadSnmpRemoteUserName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A human readable string representing the name of the user of a remote
SNMP engine."
::= { cadSnmpRemoteEngineEntry 4 }
cadSnmpRemoteEngineType OBJECT-TYPE
SYNTAX INTEGER {
manual (1),
auto (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type to indicate the remote engineID is manually configured or
internally detected via SNMP V3 Informs probe response."
DEFVAL { manual }
::= { cadSnmpRemoteEngineEntry 5 }
cadSnmpRemoteEngineStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this conceptual row."
::= { cadSnmpRemoteEngineEntry 6 }
--=========== Boot Param Objects =============================
cadSysBootMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Mac address of system controller "
::= { cadSysBootParams 1 }
cadSysBootFpIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Ip address of E6000 front panel ethernet port "
::= { cadSysBootParams 2 }
cadSysBootFpSubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" E6000 front port interface subnet mask "
::= { cadSysBootParams 3 }
cadSysBootDefaultGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Default gateway "
::= { cadSysBootParams 6 }
cadSysBootTimeOffset OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Time offset (seconds) from UTC "
::= { cadSysBootParams 7 }
cadSysBootTimeServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Ip address of TOD server "
::= { cadSysBootParams 8 }
cadSysBootTimeServerConnType OBJECT-TYPE
SYNTAX INTEGER {
tcp(1),
udp(2),
none(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Protocol (tcp/udp) used to connect to TOD server "
DEFVAL { udp }
::= { cadSysBootParams 9 }
cadSysBootStartupApplication OBJECT-TYPE
SYNTAX INTEGER {
bootprobe(1),
bootapplication(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Startup mode of the E6000 "
DEFVAL { bootapplication }
::= { cadSysBootParams 10 }
cadSysBootStartupDelay OBJECT-TYPE
SYNTAX Integer32 (1..60)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Delay (in seconds) allowing changes before booting application "
DEFVAL { 1 }
::= { cadSysBootParams 11 }
cadSysBootSelection OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Bootloader to use (1 or 2) "
DEFVAL { 1 }
::= { cadSysBootParams 12 }
cadSysBootBaud OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
" Baud rate of front panel serial port "
DEFVAL { 9600 }
::= { cadSysBootParams 13 }
cadSysBootFpBIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Ip address of E6000 side B front panel ethernet port "
::= { cadSysBootParams 15 }
cadSysBootParity OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial parity of console port. Valid values are N (no parity),
E (even parity), and O (odd parity)."
DEFVAL { "N" }
::= { cadSysBootParams 16 }
--=========== Reload Control Objects =============================
cadSysReloadOperation OBJECT-TYPE
SYNTAX INTEGER {
reloadImage(1),
reloadCommit(2),
reloadActive(3),
reloadHitless(4),
reloadWritemem(5),
reloadErasemem(6),
reloadPatchInstall(7),
reloadPatchRemove(8),
reloadPatchApply(9),
none(99)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Control object for E6000 reload, reading this object always returns none(99) "
DEFVAL { none }
::= { cadSysReload 1 }
cadSysReloadImageName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Image name to use in reloadImage operation "
DEFVAL { "" }
::= { cadSysReload 2 }
cadSysReloadStatus OBJECT-TYPE
SYNTAX BITS {
idle(0),
inProgress(1),
localCheckImage(2),
localCommit(3),
remoteCommit(4),
remoteCopyImage(5),
remoteCheckImage(6),
patchInstall(7),
localReboot(8),
patchRemove(9),
remoteFirmwareUpdate(10),
firmwareUpdate(11),
waitStandby(12),
remotePatchInstall(13),
writeMem(14),
bundling(15),
unbundling(16),
complete(17),
abort(18),
remotePatchRemove(19),
remoteWriteMem(20),
eraseMem(21),
remoteEraseMem(22),
preloadCams(23),
localInstallImage(24),
remoteInstallImage(25),
localPreloadRsm(26),
remotePreloadRsm(27),
remoteCommitRsm(28),
copyImage(29),
remoteFirmwareUpdateRsm(30),
patchApplyCheck(31),
waitSoftswitch(32),
waitSpareCamsReset(33),
waitCamsReset(34)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Status object for E6000 reload "
DEFVAL { { idle } }
::= { cadSysReload 3 }
cadSysReloadStatusDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Textual description of reload status "
DEFVAL { "" }
::= { cadSysReload 4 }
cadSysReloadPatchName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Patch image name to use in patch operations "
DEFVAL { "" }
::= { cadSysReload 5 }
--=========== Image Status Objects =============================
cadSysImageFile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Image filename for current E6000 image "
::= { cadSysImage 1 }
cadSysImageId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Image identifier for current E6000 image "
::= { cadSysImage 2 }
cadSysImageName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Image name for current E6000 image "
::= { cadSysImage 3 }
cadSysImageComponentCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Image component count for current E6000 image "
::= { cadSysImage 4 }
--=========== Dictionary Objects =============================
cadSysDictionaryTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadSysDictionaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Table describing internal state of database. "
::= { cadSysDictionary 1 }
cadSysDictionaryEntry OBJECT-TYPE
SYNTAX CadSysDictionaryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Describes the internal state of an individual table. "
INDEX { cadSysDictionaryTableId }
::= { cadSysDictionaryTable 1 }
CadSysDictionaryEntry ::= SEQUENCE {
cadSysDictionaryTableId Unsigned32,
cadSysDictionaryName DisplayString,
cadSysDictionaryDynamic TruthValue,
cadSysDictionaryNumberEntries Integer32,
cadSysDictionaryCurrentVer Unsigned32,
cadSysDictionaryPersistentVer Unsigned32,
cadSysDictionaryModuleVer Unsigned32
}
cadSysDictionaryTableId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Internal identifier for this MIB data."
::= { cadSysDictionaryEntry 1 }
cadSysDictionaryName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Internal name for this MIB data."
::= { cadSysDictionaryEntry 2 }
cadSysDictionaryDynamic OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether table is persistent or volatile only."
::= { cadSysDictionaryEntry 3 }
cadSysDictionaryNumberEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current number of rows contained in the MIB table."
::= { cadSysDictionaryEntry 4 }
cadSysDictionaryCurrentVer OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current internal dynamic version number of the MIB table."
::= { cadSysDictionaryEntry 5 }
cadSysDictionaryPersistentVer OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current internal version number of the MIB table on flash."
::= { cadSysDictionaryEntry 6 }
cadSysDictionaryModuleVer OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current internal version number of the schema of the MIB table."
::= { cadSysDictionaryEntry 7 }
--=========== Configuration Objects =============================
cadSysConfigSaveTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The date and time of the last write of the configuration to nvram. "
::= { cadSysConfiguration 1 }
--== Class of Service to Quality of Service Mapping Objects ====
--
-- These cadCostoQosMapping objects only apply to 1.0 flows.
-- To configure 1.1 flows, the objects in the docsQosParamSetTable
-- should be used.
--
cadCosToQosMappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadCosToQosMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of COS to QOS Mapping data"
::= { cadCosToQosMapping 9 }
cadCosToQosMappingEntry OBJECT-TYPE
SYNTAX CadCosToQosMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This entry contains all of the data to map
1.0 COS to 1.1 QOS parameters."
INDEX { cadCosToQosMappingIndex }
::= { cadCosToQosMappingTable 1 }
CadCosToQosMappingEntry ::= SEQUENCE {
cadCosToQosMappingIndex Integer32,
cadCosUpMaxTrafficBurst Unsigned32,
cadCosDnMaxTrafficBurst Unsigned32,
cadCosDnMinReservedRate BitRate,
cadCosUpMinReservedPkt Integer32,
cadCosDnMinReservedPkt Integer32,
cadCosUpTosAndMask OCTET STRING,
cadCosUpTosOrMask OCTET STRING,
cadCosDnMaxLatency Unsigned32,
cadCosDnPriority Integer32,
cadCosDnPeakTrafficRate BitRate,
cadCosUpPeakTrafficRate BitRate
}
cadCosToQosMappingIndex OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB
object docsQosParamSetMaxTrafficBurst"
::= { cadCosToQosMappingEntry 1 }
cadCosUpMaxTrafficBurst OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB
object docsQosParamSetMaxTrafficBurst"
DEFVAL { 3044 }
::= { cadCosToQosMappingEntry 2 }
cadCosDnMaxTrafficBurst OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The downstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB
object docsQosParamSetMaxTrafficBurst"
DEFVAL { 96000 }
::= { cadCosToQosMappingEntry 3 }
cadCosDnMinReservedRate OBJECT-TYPE
SYNTAX BitRate
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The downstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB
object docsQosParamSetMinReservedRate"
DEFVAL { 0 }
::= { cadCosToQosMappingEntry 4 }
cadCosUpMinReservedPkt OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB
object docsQosParamSetMinReservedPkt"
DEFVAL { 0 }
::= { cadCosToQosMappingEntry 5 }
cadCosDnMinReservedPkt OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The downstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB
object docsQosParamSetMinReservedPkt"
DEFVAL { 0 }
::= { cadCosToQosMappingEntry 6 }
cadCosUpTosAndMask OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB
object docsQosParamSetTosAndMask"
DEFVAL { 'ff'h }
::= { cadCosToQosMappingEntry 7 }
cadCosUpTosOrMask OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB
object docsQosParamSetTosOrMask"
DEFVAL { '00'h }
::= { cadCosToQosMappingEntry 8 }
cadCosDnMaxLatency OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB
object docsQosParamSetMaxLatency"
DEFVAL { 0 }
::= { cadCosToQosMappingEntry 9 }
cadCosDnPriority OBJECT-TYPE
SYNTAX Integer32 (-1|0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The downstream channel priority to use. A -1 indicates
that the current method of using the upstream channel
priority should be used."
DEFVAL { -1 }
::= { cadCosToQosMappingEntry 10 }
cadCosDnPeakTrafficRate OBJECT-TYPE
SYNTAX BitRate
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Peak traffic rate shaped to while traffic still conforms to
the policing parameters (Tmax and Burst). If the peak rate is set to a
value greater than Tmax, then the traffic will be shaped to the peak
rate until the traffic is non-conforming to the policing parameters,
and then the traffic will be shaped to the Tmax rate. If the peak rate
is less than the Tmax for a flow, then all traffic for that flow will shaped
to the Tmax rate. Setting the peak rate to a value of 0 will result in all
flows being limited to Tmax at all times. Setting the peak rate to a
value of 0xffffffff will result in flows having virtually unlimited
bandwidth until their burst size is used up. This parameter only has
meaning for flows on downstreams that are shaped."
DEFVAL { 0 }
::= { cadCosToQosMappingEntry 11 }
cadCosUpPeakTrafficRate OBJECT-TYPE
SYNTAX BitRate
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Peak traffic rate shaped to while traffic still conforms to
the policing parameters (Tmax and Burst). If the peak rate is set to a
value greater than Tmax, then the traffic will be shaped to the peak
rate until the traffic is non-conforming to the policing parameters,
and then the traffic will be shaped to the Tmax rate. If the peak rate
is less than the Tmax for a flow, then all traffic for that flow will shaped
to the Tmax rate. Setting the peak rate to a value of 0 will result in all
flows being limited to Tmax at all times. Setting the peak rate to a
value of 0xffffffff will result in flows having virtually unlimited
bandwidth until their burst size is used up. This parameter only has
meaning for upstream flows."
DEFVAL { 0 }
::= { cadCosToQosMappingEntry 12 }
--=========== Key Chain Objects =============================
cadSysKeyChainKeyTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadSysKeyChainKeyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Table describing key-chain key provisioned data. "
::= { cadSysKeyChain 1 }
cadSysKeyChainKeyEntry OBJECT-TYPE
SYNTAX CadSysKeyChainKeyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Describes the provisioned data for a key in a key-chain. "
INDEX { cadSysKeyChainName, cadSysKeyChainKeySequenceId }
::= { cadSysKeyChainKeyTable 1 }
CadSysKeyChainKeyEntry ::= SEQUENCE {
cadSysKeyChainName OCTET STRING,
cadSysKeyChainKeySequenceId Unsigned32,
cadSysKeyChainKey OCTET STRING,
cadSysKeyChainKeyAcceptStartTime DateAndTime,
cadSysKeyChainKeyAcceptStopTime DateAndTime,
cadSysKeyChainKeyAcceptInfiniteLifetime TruthValue,
cadSysKeyChainKeySendStartTime DateAndTime,
cadSysKeyChainKeySendStopTime DateAndTime,
cadSysKeyChainKeySendInfiniteLifetime TruthValue,
cadSysKeyChainKeyRowStatus RowStatus
}
cadSysKeyChainName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..16))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The key-chain name."
::= { cadSysKeyChainKeyEntry 1 }
cadSysKeyChainKeySequenceId OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The sequence id of the key."
::= { cadSysKeyChainKeyEntry 2 }
cadSysKeyChainKey OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..16))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The key string."
::= { cadSysKeyChainKeyEntry 3 }
cadSysKeyChainKeyAcceptStartTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The start time when this key is valid for received packets."
::= { cadSysKeyChainKeyEntry 4 }
cadSysKeyChainKeyAcceptStopTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The stop time when this key is no longer valid for received packets."
::= { cadSysKeyChainKeyEntry 5 }
cadSysKeyChainKeyAcceptInfiniteLifetime OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If this value is set to true, the key has an infinite lifetime for
received packets. Otherwise use the accept start and stop time to
determine the lifetime."
DEFVAL { true }
::= { cadSysKeyChainKeyEntry 6 }
cadSysKeyChainKeySendStartTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The start time when this key is valid for sending packets."
::= { cadSysKeyChainKeyEntry 7 }
cadSysKeyChainKeySendStopTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The stop time when this key is no longer valid for sending packets."
::= { cadSysKeyChainKeyEntry 8 }
cadSysKeyChainKeySendInfiniteLifetime OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If this value is set to true, the key has an infinite lifetime for
sending packets. Otherwise use the send start and stop time to
determine the lifetime."
DEFVAL { true }
::= { cadSysKeyChainKeyEntry 9 }
cadSysKeyChainKeyRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status variable used according to row installation
and removal convention. In our case, we have simplified this
to the usage of only the following states - active, createAndGo,
and destroy. Other three states notInService, notReady and
createAndWait are not permitted."
::= { cadSysKeyChainKeyEntry 10 }
--=========== Processor Protocol Policing Objects =============================
-- configuration objects
cadSysProcRouterControlGlobalPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted global protocol packet throttle rate to
the Router Control processor."
DEFVAL { 2500 }
::= { cadSysProcPolicingConfig 1 }
cadSysProcArpPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted ARP packet rate to the Router Control processor."
DEFVAL { 700 }
::= { cadSysProcPolicingConfig 2 }
cadSysProcDhcpPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maxmimu permitted DHCP packet rate to the Router Control processor."
DEFVAL { 750 }
::= { cadSysProcPolicingConfig 3 }
cadSysProcIcmpPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted ICMP(IPv4) packet rate to the Router Control processor."
DEFVAL { 500 }
::= { cadSysProcPolicingConfig 4 }
cadSysProcOspfPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted OSPFv2 packet rate to the Router Control processor."
DEFVAL { 750 }
::= { cadSysProcPolicingConfig 5 }
cadSysProcRipPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted RIP packet rate to the Router Control processor."
DEFVAL { 500 }
::= { cadSysProcPolicingConfig 6 }
cadSysProcIgmpPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted IGMP packet rate to the Router Control processor."
DEFVAL { 500 }
::= { cadSysProcPolicingConfig 7 }
cadSysProcRouterControlOtherPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The other protocol packet rate to the Router Control processor."
DEFVAL { 500 }
::= { cadSysProcPolicingConfig 8 }
cadSysProcSnmpPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SNMP packet rate to the System Control processor."
DEFVAL { 650 }
::= { cadSysProcPolicingConfig 10 }
cadSysProcTftpPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TFTP packet rate to the processor."
DEFVAL { 750 }
::= { cadSysProcPolicingConfig 11 }
cadSysProcIsisPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IS-IS packet rate to the processor."
DEFVAL { 750 }
::= { cadSysProcPolicingConfig 12 }
cadSysProcNdPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted Neighbor Discover (ND) packet throttle
rate to the Router Control processor. This includes IPv6 Router
Solicitation, Router Advertise, Neighbor Solicitation, Neighbor
Advertise, and Redirect messages."
DEFVAL { 700 }
::= { cadSysProcPolicingConfig 13 }
cadSysProcDhcpIpv6PacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted DHCP (Ipv6) packet throttle
rate to the Router Control processor."
DEFVAL { 500 }
::= { cadSysProcPolicingConfig 14 }
cadSysProcIcmpIpv6PacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted ICMP (Ipv6 other than Neighbor
Discover and MLD) packet throttle rate to the Router
Control processor."
DEFVAL { 500 }
::= { cadSysProcPolicingConfig 15 }
cadSysProcMldPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted MLD (version 1 and version 2)
packet throttle rate to the Router Control processor."
DEFVAL { 500 }
::= { cadSysProcPolicingConfig 16 }
cadSysProcBgpPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted BGP packet throttle rate to
the Router Control processor."
DEFVAL { 500 }
::= { cadSysProcPolicingConfig 17 }
cadSysProcPimPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted PIM packet throttle rate to
the Router Control processor."
DEFVAL { 100 }
::= { cadSysProcPolicingConfig 18 }
cadSysProcSnmpCmPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted SNMP (from CMs) packet throttle rate to
the Router Control processor."
DEFVAL { 100 }
::= { cadSysProcPolicingConfig 19 }
cadSysProcCopsPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted Cops packet throttle rate to
the Router Control processor."
DEFVAL { 300 }
::= { cadSysProcPolicingConfig 20 }
cadSysProcTelnetPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted Telnet packet throttle rate to
the Router Control processor."
DEFVAL { 300 }
::= { cadSysProcPolicingConfig 21 }
cadSysProcOspfv3PacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted OSPFv3 packet rate to the Router Control processor."
DEFVAL { 750 }
::= { cadSysProcPolicingConfig 22 }
cadSysProcTftpIpv6PacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The TFTP (IPv6) packet rate to the processor."
DEFVAL { 750 }
::= { cadSysProcPolicingConfig 23 }
cadSysProcEventIcmpPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted ICMP event packet rate to the Router Control processor."
DEFVAL { 700 }
::= { cadSysProcPolicingConfig 24 }
cadSysProcEventNoRoutePacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted No Route event packet rate to the Router Control processor."
DEFVAL { 700 }
::= { cadSysProcPolicingConfig 25 }
cadSysProcEventIcmpIpv6PacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted ICMP (IPv6) event packet rate to the Router Control processor."
DEFVAL { 700 }
::= { cadSysProcPolicingConfig 26 }
cadSysProcEventNoRouteIpv6PacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted No Route (IPv6) event packet rate to the Router Control processor."
DEFVAL { 700 }
::= { cadSysProcPolicingConfig 27 }
cadSysProcEventArpPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted ARP event packet rate to the Router Control processor."
DEFVAL { 700 }
::= { cadSysProcPolicingConfig 28 }
cadSysProcEventNdPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted ND event packet rate to the Router Control processor."
DEFVAL { 700 }
::= { cadSysProcPolicingConfig 29 }
cadSysProcEventTtlPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted TTL event packet rate to the Router Control processor."
DEFVAL { 100 }
::= { cadSysProcPolicingConfig 30 }
cadSysProcEventTtlIpv6PacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted TTL (IPv6) event packet rate to the Router Control processor."
DEFVAL { 100 }
::= { cadSysProcPolicingConfig 31 }
cadSysProcEventDadPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted DAD event packet rate to the Router Control processor."
DEFVAL { 500 }
::= { cadSysProcPolicingConfig 32 }
cadSysProcEventDefaultPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted Default event packet rate to the Router Control processor."
DEFVAL { 3000 }
::= { cadSysProcPolicingConfig 33 }
cadSysProcLdpPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The LDP (UDP and TCP) packet rate to the processor."
DEFVAL { 750 }
::= { cadSysProcPolicingConfig 34 }
cadSysProcClearPolicingCounts OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable always returns false(2) upon reading.
When set to true(1), all objects under cadSysProcPolicingCounts are cleared."
::= { cadSysProcPolicingConfig 35 }
cadSysProcLacpPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The total LACP packet rate to the processor."
DEFVAL { 200 }
::= { cadSysProcPolicingConfig 36 }
cadSysProcVrepPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The maximum permitted D6/VREP packet rate to the processor."
DEFVAL { 500 }
::= { cadSysProcPolicingConfig 37 }
cadSysProcVpmePacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The maximum permitted VPME packet rate to the processor."
DEFVAL { 30 }
::= { cadSysProcPolicingConfig 38 }
cadSysProcErmRpcPacketRate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "packets/second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum permitted RPC packet rate from an RPC ERM processor."
DEFVAL { 300 }
::= { cadSysProcPolicingConfig 39 }
--
-- count objects
--
cadSysProcRouterControlGlobalPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets received passed to the Router Control processor."
::= { cadSysProcPolicingCounts 1 }
cadSysProcRouterControlGlobalPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets received that are dropped by the Router Control processor."
::= { cadSysProcPolicingCounts 2 }
cadSysProcArpPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ARP packets received passed to the processor."
::= { cadSysProcPolicingCounts 4 }
cadSysProcArpPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ARP packets received that are dropped."
::= { cadSysProcPolicingCounts 5 }
cadSysProcDhcpPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of DHCP packets received passed to the processor."
::= { cadSysProcPolicingCounts 7 }
cadSysProcDhcpPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of DHCP packets received that are dropped."
::= { cadSysProcPolicingCounts 8 }
-- cadSysProcDhcpPacketsSent removed. do NOT reuse the OID
-- ::= { cadSysProcPolicingCounts 9 }
cadSysProcIcmpPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ICMP packets received passed to the processor."
::= { cadSysProcPolicingCounts 10 }
cadSysProcIcmpPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ICMP packets received that are dropped."
::= { cadSysProcPolicingCounts 11 }
cadSysProcOspfPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of OSPFv2 packets received passed to the processor."
::= { cadSysProcPolicingCounts 13 }
cadSysProcOspfPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of OSPFv2 packets received that are dropped."
::= { cadSysProcPolicingCounts 14 }
cadSysProcRipPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of RIP packets received passed to the processor."
::= { cadSysProcPolicingCounts 16 }
cadSysProcRipPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of RIP packets received that are dropped."
::= { cadSysProcPolicingCounts 17 }
cadSysProcIgmpPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of IGMP packets received passed to the processor."
::= { cadSysProcPolicingCounts 19 }
cadSysProcIgmpPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of IGMP packets received that are dropped."
::= { cadSysProcPolicingCounts 20 }
cadSysProcRouterControlOtherPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of other packets received passed to the Router Control processor."
::= { cadSysProcPolicingCounts 22 }
cadSysProcRouterControlOtherPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of other packets received that are dropped by the Router Control processor."
::= { cadSysProcPolicingCounts 23 }
cadSysProcSnmpPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of SNMP packets received passed to the System Control processor."
::= { cadSysProcPolicingCounts 25 }
cadSysProcSnmpPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of SNMP packets received that are dropped."
::= { cadSysProcPolicingCounts 26 }
cadSysProcTftpPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of TFTP packets received passed to the processor."
::= { cadSysProcPolicingCounts 28 }
cadSysProcTftpPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of TFTP packets received that are dropped."
::= { cadSysProcPolicingCounts 29 }
cadSysProcIsisPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of IS-IS packets received passed to the processor."
::= { cadSysProcPolicingCounts 31 }
cadSysProcIsisPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of IS-IS packets received that are dropped."
::= { cadSysProcPolicingCounts 32 }
cadSysProcNdPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Neighbor Discover packets received passed to the processor."
::= { cadSysProcPolicingCounts 37 }
cadSysProcNdPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Neighbor Discover packets received that are dropped."
::= { cadSysProcPolicingCounts 38 }
cadSysProcDhcpIpv6PacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of DHCP(Ipv6) packets received passed to the processor."
::= { cadSysProcPolicingCounts 40 }
cadSysProcDhcpIpv6PacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of DHCP(IPv6) packets received that are dropped."
::= { cadSysProcPolicingCounts 41 }
cadSysProcIcmpIpv6PacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ICMP(Ipv6) packets received passed to the processor."
::= { cadSysProcPolicingCounts 43 }
cadSysProcIcmpIpv6PacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ICMP(IPv6) packets received that are dropped."
::= { cadSysProcPolicingCounts 44 }
cadSysProcMldPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of MLD packets received passed to the processor."
::= { cadSysProcPolicingCounts 46 }
cadSysProcMldPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of MLD packets received that are dropped."
::= { cadSysProcPolicingCounts 47 }
cadSysProcBgpPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of BGP packets received passed to the processor."
::= { cadSysProcPolicingCounts 49 }
cadSysProcBgpPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of BGP packets received that are dropped."
::= { cadSysProcPolicingCounts 50 }
cadSysProcPimPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of PIM packets received passed to the processor."
::= { cadSysProcPolicingCounts 52 }
cadSysProcPimPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of PIM packets received that are dropped."
::= { cadSysProcPolicingCounts 53 }
cadSysProcSnmpCmPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of SNMP (from CMs) packets received passed to the processor."
::= { cadSysProcPolicingCounts 55 }
cadSysProcSnmpCmPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of SNMP (from CMs) packets received that are dropped."
::= { cadSysProcPolicingCounts 56 }
cadSysProcCopsPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of COPS packets received passed to the System Control processor."
::= { cadSysProcPolicingCounts 58 }
cadSysProcCopsPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of COPS packets received that are dropped."
::= { cadSysProcPolicingCounts 59 }
cadSysProcTelnetPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of TELNET packets received passed to the System Control processor."
::= { cadSysProcPolicingCounts 61 }
cadSysProcTelnetPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of TELNET packets received that are dropped."
::= { cadSysProcPolicingCounts 62 }
cadSysProcOspfv3PacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of OSPFv3 packets received passed to the processor."
::= { cadSysProcPolicingCounts 64 }
cadSysProcOspfv3PacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of OSPFv3 packets received that are dropped."
::= { cadSysProcPolicingCounts 65 }
-- cadSysProcOspfv3PacketsSent removed
-- ::= { cadSysProcPolicingCounts 66 }
cadSysProcTftpIpv6PacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of TFTP (IPv6) packets received passed to the processor."
::= { cadSysProcPolicingCounts 67 }
cadSysProcTftpIpv6PacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of TFTP (IPv6) packets received that are dropped."
::= { cadSysProcPolicingCounts 68 }
-- cadSysProcTftpIpv6PacketsSent removed, do NOT reuse the OID
-- ::= { cadSysProcPolicingCounts 69 }
cadSysProcLdpPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of LDP (UDP and TCP) packets received passed to the processor."
::= { cadSysProcPolicingCounts 70 }
cadSysProcLdpPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of LDP (UDP and TCP) packets received that are dropped."
::= { cadSysProcPolicingCounts 71 }
-- cadSysProcLdpPacketsSent removed, do NOT reuse the OID
-- ::= { cadSysProcPolicingCounts 72 }
--=========== NPU events to the host Objects ==============================
cadSysProcEventIcmpPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of ICMP event packets received passed to the processor."
::= { cadSysProcPolicingCounts 73 }
cadSysProcEventIcmpPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of ICMP event packets received that are dropped."
::= { cadSysProcPolicingCounts 74 }
cadSysProcEventNoRoutePacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of No Route event packets received passed to the processor."
::= { cadSysProcPolicingCounts 75 }
cadSysProcEventNoRoutePacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of No Route event packets received that are dropped."
::= { cadSysProcPolicingCounts 76 }
cadSysProcEventIcmpIpv6PacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of ICMP (IPv6) event packets received passed to the processor."
::= { cadSysProcPolicingCounts 77 }
cadSysProcEventIcmpIpv6PacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of ICMP (IPv6) event packets received that are dropped."
::= { cadSysProcPolicingCounts 78 }
cadSysProcEventNoRouteIpv6PacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of No Route (IPv6) event packets received passed to the processor."
::= { cadSysProcPolicingCounts 79 }
cadSysProcEventNoRouteIpv6PacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of No Route (IPv6) event packets received that are dropped."
::= { cadSysProcPolicingCounts 80 }
cadSysProcEventArpPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of ARP event packets received passed to the processor."
::= { cadSysProcPolicingCounts 81 }
cadSysProcEventArpPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of ARP event packets received that are dropped."
::= { cadSysProcPolicingCounts 82 }
cadSysProcEventNdPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of ND event packets received passed to the processor."
::= { cadSysProcPolicingCounts 83 }
cadSysProcEventNdPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of ND event packets received that are dropped."
::= { cadSysProcPolicingCounts 84 }
cadSysProcEventTtlPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of TTL event packets received passed to the processor."
::= { cadSysProcPolicingCounts 85 }
cadSysProcEventTtlPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of TTL event packets received that are dropped."
::= { cadSysProcPolicingCounts 86 }
cadSysProcEventTtlIpv6PacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of TTL (IPv6) event packets received passed to the processor."
::= { cadSysProcPolicingCounts 87 }
cadSysProcEventTtlIpv6PacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of TTL (IPv6) event packets received that are dropped."
::= { cadSysProcPolicingCounts 88 }
cadSysProcEventDadPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of DAD event packets received passed to the processor."
::= { cadSysProcPolicingCounts 89 }
cadSysProcEventDadPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of DAD event packets received that are dropped."
::= { cadSysProcPolicingCounts 90 }
cadSysProcEventDefaultPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of Default event packets received passed to the processor."
::= { cadSysProcPolicingCounts 91 }
cadSysProcEventDefaultPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of Default event packets received that are dropped."
::= { cadSysProcPolicingCounts 92 }
cadSysProcLacpPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of LACP packets received passed to the processor."
::= { cadSysProcPolicingCounts 93 }
cadSysProcLacpPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of LACP packets received that are dropped."
::= { cadSysProcPolicingCounts 94 }
cadSysProcVrepPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of D6/VREP packets received passed to the processor."
::= { cadSysProcPolicingCounts 95 }
cadSysProcVrepPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of D6/VREP packets received that are dropped."
::= { cadSysProcPolicingCounts 96 }
cadSysProcVpmePacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of VPME packets received passed to the processor."
::= { cadSysProcPolicingCounts 97 }
cadSysProcVpmePacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of VPME packets received that are dropped."
::= { cadSysProcPolicingCounts 98 }
cadSysProcErmRpcPacketsReceivedPassed OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ERM RPC packets received passed to the processor."
::= { cadSysProcPolicingCounts 99 }
cadSysProcErmRpcPacketsReceivedDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ERM RPC packets received that are dropped."
::= { cadSysProcPolicingCounts 100 }
--=========== Banner Objects ==============================
cadSysBannerMotdTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadSysBannerMotdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Table describing the MOTD banner that is displayed before the login: prompt"
::= { cadSysBanner 1 }
cadSysBannerMotdEntry OBJECT-TYPE
SYNTAX CadSysBannerMotdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Describes a line in the MOTD banner"
INDEX { cadSysBannerMotdLine }
::= { cadSysBannerMotdTable 1 }
CadSysBannerMotdEntry ::= SEQUENCE {
cadSysBannerMotdLine Integer32,
cadSysBannerMotdText DisplayString,
cadSysBannerMotdRowStatus RowStatus
}
cadSysBannerMotdLine OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The line number"
::= { cadSysBannerMotdEntry 1 }
cadSysBannerMotdText OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The MOTD banner text"
::= { cadSysBannerMotdEntry 2 }
cadSysBannerMotdRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status variable used according to row installation
and removal convention. In our case, we have simplified this
to the usage of only the following states - active, createAndGo,
and destroy. Other three states notInService, notReady and
createAndWait are not permitted."
::= { cadSysBannerMotdEntry 3 }
cadSysBannerLoginTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadSysBannerLoginEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Table describing the login banner that is displayed after the MOTD banner and before the login: prompt"
::= { cadSysBanner 2 }
cadSysBannerLoginEntry OBJECT-TYPE
SYNTAX CadSysBannerLoginEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Describes a line in the login banner"
INDEX { cadSysBannerLoginLine }
::= { cadSysBannerLoginTable 1 }
CadSysBannerLoginEntry ::= SEQUENCE {
cadSysBannerLoginLine Integer32,
cadSysBannerLoginText DisplayString,
cadSysBannerLoginRowStatus RowStatus
}
cadSysBannerLoginLine OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The line number"
::= { cadSysBannerLoginEntry 1 }
cadSysBannerLoginText OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The login banner text"
::= { cadSysBannerLoginEntry 2 }
cadSysBannerLoginRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status variable used according to row installation
and removal convention. In our case, we have simplified this
to the usage of only the following states - active, createAndGo,
and destroy. Other three states notInService, notReady and
createAndWait are not permitted."
::= { cadSysBannerLoginEntry 3 }
cadSysBannerExecTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadSysBannerExecEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { cadSysBanner 3 }
cadSysBannerExecEntry OBJECT-TYPE
SYNTAX CadSysBannerExecEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { cadSysBannerExecLine }
::= { cadSysBannerExecTable 1 }
CadSysBannerExecEntry ::= SEQUENCE {
cadSysBannerExecLine Integer32,
cadSysBannerExecText DisplayString,
cadSysBannerExecRowStatus RowStatus
}
cadSysBannerExecLine OBJECT-TYPE
SYNTAX Integer32 (1..25)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of this banner line."
::= { cadSysBannerExecEntry 1 }
cadSysBannerExecText OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Ascii text of this banner line."
::= { cadSysBannerExecEntry 2 }
cadSysBannerExecRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status variable used according to row installation
and removal convention. In our case, we have simplified this
to the usage of only the following states - active, createAndGo,
and destroy. Other three states notInService, notReady and
createAndWait are not permitted."
::= { cadSysBannerExecEntry 3 }
cadSysBannerIncomingTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadSysBannerIncomingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { cadSysBanner 4 }
cadSysBannerIncomingEntry OBJECT-TYPE
SYNTAX CadSysBannerIncomingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { cadSysBannerIncomingLine }
::= { cadSysBannerIncomingTable 1 }
CadSysBannerIncomingEntry ::= SEQUENCE {
cadSysBannerIncomingLine Integer32,
cadSysBannerIncomingText DisplayString,
cadSysBannerIncomingRowStatus RowStatus
}
cadSysBannerIncomingLine OBJECT-TYPE
SYNTAX Integer32 (1..25)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { cadSysBannerIncomingEntry 1 }
cadSysBannerIncomingText OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
""
::= { cadSysBannerIncomingEntry 2 }
cadSysBannerIncomingRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status variable used according to row installation
and removal convention. In our case, we have simplified this
to the usage of only the following states - active, createAndGo,
and destroy. Other three states notInService, notReady and
createAndWait are not permitted."
::= { cadSysBannerIncomingEntry 3 }
--=========== Server Objects ==============================
cadSysServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadSysServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Table describing the (INET) services that should run on the SCM."
::= { cadSysServer 1 }
cadSysServerEntry OBJECT-TYPE
SYNTAX CadSysServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Describes an INET service and whether it is enabled "
INDEX { cadSysServerType }
::= { cadSysServerTable 1 }
CadSysServerEntry ::= SEQUENCE {
cadSysServerType ServerType,
cadSysServerAdminState AdminState
}
cadSysServerType OBJECT-TYPE
SYNTAX ServerType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The service type"
::= { cadSysServerEntry 1 }
cadSysServerAdminState OBJECT-TYPE
SYNTAX AdminState
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The administrative state of the server."
DEFVAL { up }
::= { cadSysServerEntry 2 }
--=========== Patch Parameter Objects =============================
cadSysPatchParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadSysPatchParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of patch parameters."
::= { cadSysPatchParams 1 }
cadSysPatchParamEntry OBJECT-TYPE
SYNTAX CadSysPatchParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry of an individual patch parameter."
INDEX { cadSysPatchParamIndex }
::= { cadSysPatchParamTable 1 }
CadSysPatchParamEntry ::= SEQUENCE {
cadSysPatchParamIndex Integer32,
cadSysPatchParamName DisplayString,
cadSysPatchParamValue DisplayString,
cadSysPatchParamDescription DisplayString,
cadSysPatchParamRowStatus RowStatus
}
cadSysPatchParamIndex OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The patch parameter index."
::= { cadSysPatchParamEntry 1 }
cadSysPatchParamName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The patch parameter name."
::= { cadSysPatchParamEntry 2 }
cadSysPatchParamValue OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The patch parameter value."
::= { cadSysPatchParamEntry 3 }
cadSysPatchParamDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The patch parameter description."
::= { cadSysPatchParamEntry 4 }
cadSysPatchParamRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status variable used according to row installation
and removal convention. In our case, we have simplified this
to the usage of only the following states - active, createAndGo,
and destroy. Other three states notInService, notReady and
createAndWait are not permitted."
::= { cadSysPatchParamEntry 5 }
--=========== Maintenance Configuration ==============================
cadSysMtceStatusCloneMonitorThreshold OBJECT-TYPE
SYNTAX Unsigned32 (2750..6250)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Timeout during normal operation."
DEFVAL { 6000 }
::= { cadSysMtceParams 8 }
cadSysMtceStatusCloneInitThreshold OBJECT-TYPE
SYNTAX Unsigned32 (3000..9000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Timeout on initialization for first status message."
DEFVAL { 7500 }
::= { cadSysMtceParams 9 }
cadSysMtceStatusCloneRcvyThreshold OBJECT-TYPE
SYNTAX Unsigned32 (120000..360000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Timeout following clone side recovery."
DEFVAL { 240000 }
::= { cadSysMtceParams 10 }
cadSysMtceBasePingRate OBJECT-TYPE
SYNTAX Unsigned32 (750..2250)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Interval between system maintenance polling of monitored threads."
DEFVAL { 2000 }
::= { cadSysMtceParams 11 }
cadSysMtceOvSensitivity OBJECT-TYPE
SYNTAX OverloadThreshold
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the sensitivity of user overload to changes in
internal work load. Higher sensitivity results in more
rapid change of user overload in response to a change in
the internal work load."
DEFVAL { med }
::= { cadSysMtceParams 12 }
cadSysMtceOvThreshold OBJECT-TYPE
SYNTAX OverloadThreshold
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the overall threshold of user overload transitions.
Higher thresholds require a longer time in an internal overload
state before user overload transitions occur."
DEFVAL { med }
::= { cadSysMtceParams 13 }
cadSysMtceDULPacketInterval OBJECT-TYPE
SYNTAX Unsigned32(0|10000..900000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Interval between maintenance polling of monitored BroadCom devices.
Setting the value to zero will disable BroadCom device monitoring."
DEFVAL { 10000 }
::= { cadSysMtceParams 14 }
--=========== Data Management ==============================--
cadSysDataServerDataTimeout OBJECT-TYPE
SYNTAX Unsigned32 (50000..500000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time allowed for Data Query/Update to be processed."
DEFVAL { 50000 }
::= { cadSysDataServer 1 }
cadSysDataServerDataEventsPerCycle OBJECT-TYPE
SYNTAX Unsigned32 (10..200)
UNITS "events/cycle"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of data events allowed per cycle."
DEFVAL { 40 }
::= { cadSysDataServer 2 }
cadSysDataServerDataSyncTimeout OBJECT-TYPE
SYNTAX Unsigned32 (8000..100000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of data events allowed per cycle."
DEFVAL { 80000 }
::= { cadSysDataServer 3 }
cadSysDataServerSnmpReadAheadEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this value is set to true Snmp read ahead
is performed."
DEFVAL { true }
::= { cadSysDataServer 4 }
cadSysDataServerSnmpReadAheadMax OBJECT-TYPE
SYNTAX Unsigned32 (0..20)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value is the maximum number of records to read ahead"
DEFVAL { 1 }
::= { cadSysDataServer 5 }
cadSysDataServerSnmpRefreshTime OBJECT-TYPE
SYNTAX Unsigned32 (1..1200)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value represents how old a database record can be to be used."
DEFVAL { 1 }
::= { cadSysDataServer 6 }
cadSysDataServerSyncDataEventsPerCycle OBJECT-TYPE
SYNTAX Unsigned32 (40..100)
UNITS "events/cycle"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value is the maximum number of Sync events that will be
processed per cycle."
DEFVAL { 40 }
::= { cadSysDataServer 7 }
cadSysDataServerLoPriDataEventsPerCycle OBJECT-TYPE
SYNTAX Unsigned32 (10..100)
UNITS "events/cycle"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value is the maximum number of Low Priority Sync events
to be processed per cycle."
DEFVAL { 10 }
::= { cadSysDataServer 8 }
--============================ Source Interface and Address ===========================
cadSysSourceAddressTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadSysSourceAddressEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of source interface addresses for administrative services"
::= { cadSysSourceAddress 1 }
cadSysSourceAddressEntry OBJECT-TYPE
SYNTAX CadSysSourceAddressEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This entry contains the configured source IPv4 and/or IPv6 address for each administrative service.
If configured, it also contains the global default address."
INDEX { cadSysSourceAddressIndex }
::= { cadSysSourceAddressTable 1 }
CadSysSourceAddressEntry ::= SEQUENCE {
cadSysSourceAddressIndex AdminSrcAddrType,
cadSysSourceInterfaceIpv4IfIndex InterfaceIndexOrZero,
cadSysSourceAddressIpv4Address InetAddressIPv4,
cadSysSourceInterfaceIpv6IfIndex InterfaceIndexOrZero,
cadSysSourceAddressIpv6Address InetAddressIPv6
}
cadSysSourceAddressIndex OBJECT-TYPE
SYNTAX AdminSrcAddrType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The type of administrative service."
::= { cadSysSourceAddressEntry 1 }
cadSysSourceInterfaceIpv4IfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ifIndex of the interface from which all IPv4 packets are sourced.
For a server service, it is also the only DIP allowed for incoming requests.
A value of 0 indicates no source interface override."
DEFVAL { 0 }
::= { cadSysSourceAddressEntry 2 }
cadSysSourceAddressIpv4Address OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IPv4 address of the IPv4 interface at the time the row ipv4 ifIndex was populated.
Used as the source address for the service if the state is in-service.
For a server service, it is also the only DIP allowed for incoming requests.
A value of null indicates no source address has been assigned."
DEFVAL { "" }
::= { cadSysSourceAddressEntry 3 }
cadSysSourceInterfaceIpv6IfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ifIndex of the interface from which all IPv6 packets are sourced (not currently supported).
For a server service, it is also the only DIP allowed for incoming requests.
A value of 0 indicates no source interface override."
DEFVAL { 0 }
::= { cadSysSourceAddressEntry 4 }
cadSysSourceAddressIpv6Address OBJECT-TYPE
SYNTAX InetAddressIPv6
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IPv6 address of the IPv6 interface
at the time the ipv6 ifIndex was populated.
Used as the source address for the service if the state is in-service.
For a server service, it is also the only DIP allowed for incoming requests.
A value of null indicates no source address has been assigned."
DEFVAL { "" }
::= { cadSysSourceAddressEntry 5}
--========================== License Control ==========================--
cadSysLicenseCardId OBJECT-TYPE
SYNTAX CardId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"CAM to be licensed."
DEFVAL { 0 }
::= { cadSysLicenseControl 1 }
cadSysLicenseKey OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"License key to apply to the CAM."
DEFVAL { ''h }
::= { cadSysLicenseControl 2 }
cadSysLicensePorts OBJECT-TYPE
SYNTAX Integer32(0..5000)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of CAM ports associated with the license."
DEFVAL { 0 }
::= { cadSysLicenseControl 3 }
cadSysLicenseAnnex OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
annexA(3),
annexB(4),
annexC(5)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This attribute defines the ITU-J-83 Annex being used
for this E6000 CMTS License."
DEFVAL { unknown }
::= { cadSysLicenseControl 4 }
cadSysLicenseStatus OBJECT-TYPE
SYNTAX INTEGER
{
success(1),
fail(2),
pending(3),
none(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of licensing operation."
DEFVAL { none }
::= { cadSysLicenseControl 5 }
--============================ LAES Mediation Device Timestamp Mode Table ===========================
cadLaesMdTimestampModeTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadLaesMdTimestampModeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of LAES Mediation Device Timestamp mode table"
::= { cadLaesMdTimestampMode 1 }
cadLaesMdTimestampModeEntry OBJECT-TYPE
SYNTAX CadLaesMdTimestampModeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This entry contains the configured MD IPv4.
If configured, then all encapsulated tap packets going to that MD will contain
a timestamp in the tap header."
INDEX { cadLaesMdTimestampModeInetAddrType, cadLaesMdTimestampModeInetAddr}
::= { cadLaesMdTimestampModeTable 1 }
CadLaesMdTimestampModeEntry ::= SEQUENCE {
cadLaesMdTimestampModeInetAddrType InetAddressType,
cadLaesMdTimestampModeInetAddr InetAddress,
cadLaesMdTimestampModRowStatus RowStatus
}
cadLaesMdTimestampModeInetAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The IP Address type of Mediation Device"
::= { cadLaesMdTimestampModeEntry 1 }
cadLaesMdTimestampModeInetAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The IP Address of the Mediation Device."
::= { cadLaesMdTimestampModeEntry 2 }
cadLaesMdTimestampModRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of this entry"
::= { cadLaesMdTimestampModeEntry 3 }
---========================= cadSysMICSecondarySecretTable ==========================--
cadSysMICSecondarySecretTable OBJECT-TYPE
SYNTAX SEQUENCE OF CadSysMICSecondarySecretEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table containing secondary shared secret strings for
cable modem configuration file authentication. This
table is not used unless cadSysMICEnable is set to
true."
::= { cadSysSharedSecret 1 }
cadSysMICSecondarySecretEntry OBJECT-TYPE
SYNTAX CadSysMICSecondarySecretEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry containing secondary shared secret strings for
cable modem configuration file authentication."
INDEX { cadSysMICSecondarySecretIndex }
::= { cadSysMICSecondarySecretTable 1 }
CadSysMICSecondarySecretEntry ::= SEQUENCE {
cadSysMICSecondarySecretIndex INTEGER,
cadSysMICSecondarySecretString OCTET STRING,
cadSysMICSecondarySecretStatus RowStatus
}
cadSysMICSecondarySecretIndex OBJECT-TYPE
SYNTAX INTEGER (1..1)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Internal index for this MIB row."
::= { cadSysMICSecondarySecretEntry 1 }
cadSysMICSecondarySecretString OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..64))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" Encrypted MIC Authentication shared secret string."
::= { cadSysMICSecondarySecretEntry 2 }
cadSysMICSecondarySecretStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this conceptual row."
::= { cadSysMICSecondarySecretEntry 3 }
---
--- Conformance information
---
cadSystemMibConformance OBJECT IDENTIFIER ::= { cadSystemMib 12 }
cadSystemCompliances OBJECT IDENTIFIER ::= { cadSystemMibConformance 1 }
cadSystemGroups OBJECT IDENTIFIER ::= { cadSystemMibConformance 2 }
cadSystemCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for entities implementing the Cadant System Mib."
MODULE -- this module
MANDATORY-GROUPS {
cadSysParamsGroup, cadSysSystemGroup,
cadSysControlGroup, cadSysSnmpGroup,
cadSysBootParamsGroup, cadSysReloadGroup,
cadSysImageGroup, cadSysDataServerGroup,
cadSysSourceAddressGroup }
::= { cadSystemCompliances 1 }
cadSysParamsGroup OBJECT-GROUP
OBJECTS {
cadSysSyncInterval,
cadSysUCDInterval,
cadSysMaxMAPPending,
cadSysRangingInterval,
cadSysInvitedRangingRetries,
cadSysRegistrationRequestRetries,
cadSysCMMAPProcessingTime,
cadSysCMConfiguration,
cadSysT5Timeout,
cadSysT6Timeout,
cadSysMiniSlotSize,
cadSysDSxRequestRetries,
cadSysT7Timeout,
cadSysT8Timeout,
cadSysT9Timeout,
cadSysT10Timeout,
cadSysT11Timeout,
cadSysT13Timeout,
cadSysDCCREQRetries,
cadSysMICEnable,
cadSysMICAuthString,
cadSysAutoRecoveryEnable,
cadSysActiveIpAddress,
cadSysSpOperMode,
cadSysMaxQoSActiveTimeout,
cadSysMaxQoSAdmittedTimeout,
cadSysAllow10CmConcatenation,
cadSysAllow10CmFragmentation,
cadSysPercentAddtlDsBwAllocated,
cadSysMaxTrafBurstFor11CMs,
cadSysRemoteFSEnable,
cadSysRemotePortEnable,
cadSysTcpSmoothingValue1D8U,
cadSysTcpSmoothingValue2D12U,
cadSysModemLossThreshold,
cadSysPeakTrafRateFor11CMs,
cadSysCpeHostAuthorization
}
STATUS current
DESCRIPTION
"System parameter objects"
::= { cadSystemGroups 1 }
cadSysSystemGroup OBJECT-GROUP
OBJECTS {
cadSysContact,
cadSysName,
cadSysLocation
}
STATUS current
DESCRIPTION
"System description objects"
::= { cadSystemGroups 2 }
cadSysControlGroup OBJECT-GROUP
OBJECTS {
cadSysWriteMem,
cadSysEraseMem
}
STATUS deprecated
DESCRIPTION
"System control objects"
::= { cadSystemGroups 3 }
cadSysSnmpGroup OBJECT-GROUP
OBJECTS {
cadSysEnableAuthenTraps,
cadSysSnmpReadAheadMax,
cadSysSnmpRefreshTime
}
STATUS current
DESCRIPTION
"System snmp control object"
::= { cadSystemGroups 4 }
cadSysBootParamsGroup OBJECT-GROUP
OBJECTS {
cadSysBootMacAddress,
cadSysBootFpIpAddress,
cadSysBootFpSubnetMask,
cadSysBootDefaultGateway,
cadSysBootTimeOffset,
cadSysBootTimeServer,
cadSysBootTimeServerConnType,
cadSysBootStartupApplication,
cadSysBootStartupDelay,
cadSysBootSelection
}
STATUS current
DESCRIPTION
"System boot parameters objects"
::= { cadSystemGroups 5 }
cadSysReloadGroup OBJECT-GROUP
OBJECTS {
cadSysReloadImageName,
cadSysReloadOperation,
cadSysReloadStatus
}
STATUS current
DESCRIPTION
"System reload control objects"
::= { cadSystemGroups 6 }
cadSysImageGroup OBJECT-GROUP
OBJECTS {
cadSysImageFile,
cadSysImageId,
cadSysImageName,
cadSysImageComponentCount
}
STATUS current
DESCRIPTION
"System image status objects"
::= { cadSystemGroups 7 }
cadSysConfigurationGroup OBJECT-GROUP
OBJECTS {
cadSysConfigSaveTime
}
STATUS current
DESCRIPTION
"Configuration objects"
::= { cadSystemGroups 8 }
cadSysDataServerGroup OBJECT-GROUP
OBJECTS {
cadSysDataServerDataTimeout,
cadSysDataServerDataEventsPerCycle,
cadSysDataServerDataSyncTimeout,
cadSysDataServerSnmpReadAheadEnable,
cadSysDataServerSnmpReadAheadMax,
cadSysDataServerSnmpRefreshTime,
cadSysDataServerSyncDataEventsPerCycle,
cadSysDataServerLoPriDataEventsPerCycle
}
STATUS current
DESCRIPTION
"Configuration objects"
::= { cadSystemGroups 9 }
cadSysSourceAddressGroup OBJECT-GROUP
OBJECTS {
cadSysSourceInterfaceIpv4IfIndex,
cadSysSourceAddressIpv4Address,
cadSysSourceInterfaceIpv6IfIndex,
cadSysSourceAddressIpv6Address
}
STATUS current
DESCRIPTION
"Source Interface objects."
::= { cadSystemGroups 10 }
END -- end of CADANT-CMTS-SYSTEM-MIB