-- Trend Micro, Inc.
|
|
-- Copyright information is in the DESCRIPTION section of the MODULE-IDENTITY.
|
|
--
|
|
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
|
|
|
TPT-HEALTH-MIB
|
|
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
Unsigned32
|
|
FROM SNMPv2-SMI
|
|
|
|
TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
|
|
tpt-tpa-objs
|
|
FROM TPT-TPAMIBS-MIB
|
|
;
|
|
|
|
tpt-health-objs MODULE-IDENTITY
|
|
LAST-UPDATED "201605251854Z" -- May 25, 2016
|
|
ORGANIZATION "Trend Micro, Inc."
|
|
CONTACT-INFO "www.trendmicro.com"
|
|
DESCRIPTION
|
|
"Health information: temperatures, fan speeds, and voltage levels.
|
|
|
|
Copyright (C) 2016 Trend Micro Incorporated. All Rights Reserved.
|
|
|
|
Trend Micro makes no warranty of any kind with regard to this material,
|
|
including, but not limited to, the implied warranties of merchantability
|
|
and fitness for a particular purpose. Trend Micro shall not be liable for
|
|
errors contained herein or for incidental or consequential damages in
|
|
connection with the furnishing, performance, or use of this material. This
|
|
document contains proprietary information, which is protected by copyright. No
|
|
part of this document may be photocopied, reproduced, or translated into
|
|
another language without the prior written consent of Trend Micro. The
|
|
information is provided 'as is' without warranty of any kind and is subject to
|
|
change without notice. The only warranties for Trend Micro products and
|
|
services are set forth in the express warranty statements accompanying such
|
|
products and services. Nothing herein should be construed as constituting an
|
|
additional warranty. Trend Micro shall not be liable for technical or editorial
|
|
errors or omissions contained herein. TippingPoint(R), the TippingPoint logo, and
|
|
Digital Vaccine(R) are registered trademarks of Trend Micro. All other company
|
|
and product names may be trademarks of their respective holders. All rights
|
|
reserved. This document contains confidential information, trade secrets or
|
|
both, which are the property of Trend Micro. No part of this documentation may
|
|
be reproduced in any form or by any means or used to make any derivative work
|
|
(such as translation, transformation, or adaptation) without written permission
|
|
from Trend Micro or one of its subsidiaries. All other company and product
|
|
names may be trademarks of their respective holders.
|
|
"
|
|
|
|
REVISION "201605251854Z" -- May 25, 2016
|
|
DESCRIPTION "Updated copyright information. Minor MIB syntax fixes."
|
|
|
|
::= { tpt-tpa-objs 13 }
|
|
|
|
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
|
--
|
|
-- Textual conventions for health objects
|
|
--
|
|
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
|
|
|
HealthSeverity ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A qualitative description of the state of a health value."
|
|
SYNTAX INTEGER { normal(0), info(1), minor(2), major(3), critical(4) }
|
|
|
|
HealthThresholdType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"How to apply thresholds to see if a value is operating correctly:
|
|
- minimum: value should not go below thresholds.
|
|
- range: value should be within nominal plus or minus thresholds.
|
|
- maximum: value should not go above thresholds."
|
|
SYNTAX INTEGER { minimum(1), range(2), maximum(3) }
|
|
|
|
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
|
--
|
|
-- Table of temperatures
|
|
--
|
|
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
|
|
|
healthTempTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HealthTempEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of temperatures at various places inside the device."
|
|
::= { tpt-health-objs 1 }
|
|
|
|
healthTempEntry OBJECT-TYPE
|
|
SYNTAX HealthTempEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the temperature table.
|
|
Rows cannot be created or deleted."
|
|
INDEX { healthTempIndex }
|
|
::= { healthTempTable 1 }
|
|
|
|
HealthTempEntry ::= SEQUENCE {
|
|
healthTempIndex Unsigned32,
|
|
healthTempChannel OCTET STRING (SIZE (0..64)),
|
|
healthTempValue Unsigned32,
|
|
healthTempSeverity HealthSeverity,
|
|
healthTempThresholdType HealthThresholdType,
|
|
healthTempMajor Unsigned32,
|
|
healthTempCritical Unsigned32
|
|
}
|
|
|
|
healthTempIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index into the temperature table, starting with 1."
|
|
::= { healthTempEntry 1 }
|
|
|
|
healthTempChannel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String description of the location of this temperature sensor."
|
|
::= { healthTempEntry 2 }
|
|
|
|
healthTempValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature in degrees centigrade at this sensor."
|
|
::= { healthTempEntry 3 }
|
|
|
|
healthTempSeverity OBJECT-TYPE
|
|
SYNTAX HealthSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Whether this temperature is normal or too hot."
|
|
::= { healthTempEntry 4 }
|
|
|
|
healthTempThresholdType OBJECT-TYPE
|
|
SYNTAX HealthThresholdType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"How to apply thresholds to see if this value is within operating range."
|
|
::= { healthTempEntry 5 }
|
|
|
|
healthTempMajor OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The major threshold temperature (degrees C)."
|
|
::= { healthTempEntry 6 }
|
|
|
|
healthTempCritical OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The critical threshold temperature (degrees C)."
|
|
::= { healthTempEntry 7 }
|
|
|
|
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
|
--
|
|
-- Table of fans
|
|
--
|
|
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
|
|
|
healthFanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HealthFanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of fans for the device."
|
|
::= { tpt-health-objs 2 }
|
|
|
|
healthFanEntry OBJECT-TYPE
|
|
SYNTAX HealthFanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the fan table.
|
|
Rows cannot be created or deleted."
|
|
INDEX { healthFanIndex }
|
|
::= { healthFanTable 1 }
|
|
|
|
HealthFanEntry ::= SEQUENCE {
|
|
healthFanIndex Unsigned32,
|
|
healthFanChannel OCTET STRING (SIZE (0..64)),
|
|
healthFanValue Unsigned32,
|
|
healthFanSeverity HealthSeverity,
|
|
healthFanThresholdType HealthThresholdType,
|
|
healthFanMajor Unsigned32,
|
|
healthFanCritical Unsigned32
|
|
}
|
|
|
|
healthFanIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index into the fan table, starting with 1."
|
|
::= { healthFanEntry 1 }
|
|
|
|
healthFanChannel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifier of this fan."
|
|
::= { healthFanEntry 2 }
|
|
|
|
healthFanValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The speed of this fan in RPM."
|
|
::= { healthFanEntry 3 }
|
|
|
|
healthFanSeverity OBJECT-TYPE
|
|
SYNTAX HealthSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Whether this fan speed is normal or too slow."
|
|
::= { healthFanEntry 4 }
|
|
|
|
healthFanThresholdType OBJECT-TYPE
|
|
SYNTAX HealthThresholdType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"How to apply thresholds to see if this value is within operating range."
|
|
::= { healthFanEntry 5 }
|
|
|
|
healthFanMajor OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The major threshold fan speed (RPM)."
|
|
::= { healthFanEntry 6 }
|
|
|
|
healthFanCritical OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The critical threshold fan speed (RPM)."
|
|
::= { healthFanEntry 7 }
|
|
|
|
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
|
--
|
|
-- Table of voltages
|
|
--
|
|
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
|
|
|
healthVoltageTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HealthVoltageEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of voltages at various places inside the device."
|
|
::= { tpt-health-objs 3 }
|
|
|
|
healthVoltageEntry OBJECT-TYPE
|
|
SYNTAX HealthVoltageEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the voltage table.
|
|
Rows cannot be created or deleted."
|
|
INDEX { healthVoltageIndex }
|
|
::= { healthVoltageTable 1 }
|
|
|
|
HealthVoltageEntry ::= SEQUENCE {
|
|
healthVoltageIndex Unsigned32,
|
|
healthVoltageChannel OCTET STRING (SIZE (0..64)),
|
|
healthVoltageValue Unsigned32,
|
|
healthVoltageSeverity HealthSeverity,
|
|
healthVoltageThresholdType HealthThresholdType,
|
|
healthVoltageMajor Unsigned32,
|
|
healthVoltageCritical Unsigned32,
|
|
healthVoltageNominal Unsigned32
|
|
}
|
|
|
|
healthVoltageIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index into the voltage table, starting with 1."
|
|
::= { healthVoltageEntry 1 }
|
|
|
|
healthVoltageChannel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String description of the location of this voltage sensor."
|
|
::= { healthVoltageEntry 2 }
|
|
|
|
healthVoltageValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The voltage reading in millivolts at this sensor."
|
|
::= { healthVoltageEntry 3 }
|
|
|
|
healthVoltageSeverity OBJECT-TYPE
|
|
SYNTAX HealthSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Whether this voltage is within the normal operating range or not."
|
|
::= { healthVoltageEntry 4 }
|
|
|
|
healthVoltageThresholdType OBJECT-TYPE
|
|
SYNTAX HealthThresholdType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"How to apply thresholds to see if this value is within operating range."
|
|
::= { healthVoltageEntry 5 }
|
|
|
|
healthVoltageMajor OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The major threshold voltage (mV) delta (above or below nominal)."
|
|
::= { healthVoltageEntry 6 }
|
|
|
|
healthVoltageCritical OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The critical threshold voltage (mV) delta (above or below nominal)."
|
|
::= { healthVoltageEntry 7 }
|
|
|
|
healthVoltageNominal OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"What the voltage (mV) reading at this sensor should be."
|
|
::= { healthVoltageEntry 8 }
|
|
|
|
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
|
--
|
|
-- Table of I2C bus timeouts
|
|
--
|
|
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
|
|
|
|
healthI2CTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HealthI2CEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of I2C bus timsouts."
|
|
::= { tpt-health-objs 4 }
|
|
|
|
healthI2CEntry OBJECT-TYPE
|
|
SYNTAX HealthI2CEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the I2C bus table.
|
|
Rows cannot be created or deleted."
|
|
INDEX { healthI2CIndex }
|
|
::= { healthI2CTable 1 }
|
|
|
|
HealthI2CEntry ::= SEQUENCE {
|
|
healthI2CIndex Unsigned32,
|
|
healthI2CChannel OCTET STRING (SIZE (0..64)),
|
|
healthI2CValue Unsigned32,
|
|
healthI2CSeverity HealthSeverity,
|
|
healthI2CThresholdType HealthThresholdType,
|
|
healthI2CMajor Unsigned32,
|
|
healthI2CCritical Unsigned32
|
|
}
|
|
|
|
healthI2CIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index into the I2C bus table, starting with 1."
|
|
::= { healthI2CEntry 1 }
|
|
|
|
healthI2CChannel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String description of this I2C bus."
|
|
::= { healthI2CEntry 2 }
|
|
|
|
healthI2CValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of timeouts on this I2C bus since boot."
|
|
::= { healthI2CEntry 3 }
|
|
|
|
healthI2CSeverity OBJECT-TYPE
|
|
SYNTAX HealthSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Whether this number of I2C bus timeouts is acceptable or excessive."
|
|
::= { healthI2CEntry 4 }
|
|
|
|
healthI2CThresholdType OBJECT-TYPE
|
|
SYNTAX HealthThresholdType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"How to apply thresholds to see if this value is within operating range."
|
|
::= { healthI2CEntry 5 }
|
|
|
|
healthI2CMajor OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The major threshold number of I2C bus timeouts."
|
|
::= { healthI2CEntry 6 }
|
|
|
|
healthI2CCritical OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The critical threshold number of I2C bus timeouts."
|
|
::= { healthI2CEntry 7 }
|
|
|
|
|
|
END
|
|
|