Observium_CE/mibs/pandacom/SPEEDCARRIER-MIB

3742 lines
88 KiB
Plaintext

SPEEDCARRIER-MIB DEFINITIONS ::= BEGIN
--***** Version History ***************************************************************
--V1.0 09.11.2006 ML: first version SPEEDCARRIER-MIB
--V3.0 08.04.2009 GD: added new subtrees for multiplexer and ammplifier
--V5.0 20.04.2011 ML: added SW update and config handling over Backplane
-- Supported Modules:
-- SPEED-DUALLINE SFP 3R
-- SPEED-DUALLINE SFP 3R PROTECTION
-- SPEED-DUALLINE SFP
-- SPEED-SINGLELINE SFP
-- SPEED-SINGLELINE XFP (SPEEDSINGLELINE-XFP-MIB)
-- SPEED-SINGLELINE XFP 3R (SPEEDSINGLELINE-XFP-MIB)
-- SPEED-DUALLINE FC SFP+ and XFP (SPEED-DUALLINE-FC, also 16G cards)
-- SPEED-DUALLINE 10G SFP+ and XFP (obsolete. Is supported in SPEED-DUALLINE-FC)
-- SPEED-AMP's (EDFA and RAMAN) (SPEED-AMP-MIB)
IMPORTS
DisplayString FROM RFC1213-MIB
OBJECT-TYPE FROM RFC-1212
TRAP-TYPE FROM RFC-1215
enterprises, IpAddress, TimeTicks, MODULE-IDENTITY FROM SNMPv2-SMI
PanDacom FROM PanDacom-MIB;
-- SPEEDCARRIER OBJECT IDENTIFIER ::= { PanDacom 3 }
nmSPEEDCARRIER MODULE-IDENTITY
LAST-UPDATED "1312120000Z"
ORGANIZATION "Pan Dacom Direkt GmbH"
CONTACT-INFO
"Pan Dacom Direkt GmbH
Dreieich Plaza 1B
63303 Dreieich
Germany
Tel. : +49 6103/83483-333
Fax. : +49 6103/83483-444
email: kontakt@pandacomdirekt.de
web : www.pandacomdirekt.de"
DESCRIPTION "Revision 2.0"
REVISION "1312120000Z" -- Dec. 12, 2013
DESCRIPTION "Revision 5.2.0
- change of table indexes to slot or port
- IPv6 support. So changed parameters like Trapsinks, NTP
and RADIUS server address from IpAddress to
DisplayString
- new table for RADIUS server configs"
::= { PanDacom 3 }
nmAgent OBJECT IDENTIFIER ::= { nmSPEEDCARRIER 1 }
nmAgentGeneralInfo OBJECT IDENTIFIER ::= { nmAgent 1 }
nmAVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SPEED-NMS Ramdisk Version"
::= { nmAgentGeneralInfo 1 }
nmASlot OBJECT-TYPE
SYNTAX INTEGER (0..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot in which the SPEED-NMS card is inserted"
::= { nmAgentGeneralInfo 2 }
nmADate OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Date of the SPEED-NMS system"
::= { nmAgentGeneralInfo 3 }
nmATime OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual Time of the SPEED-NMS system"
::= { nmAgentGeneralInfo 4 }
nmAUpTime OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System uptime of the SPEED-NMS system"
::= { nmAgentGeneralInfo 5 }
nmATemperature OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Board temperature of the SPEED-NMS system"
::= { nmAgentGeneralInfo 6 }
nmAAlarmState OBJECT-TYPE
SYNTAX INTEGER
{
noAlarms(0),
activeAlarms(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm state of the SPEED-NMS system"
::= { nmAgentGeneralInfo 7 }
nmASerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial number of the SPEED-NMS system"
::= { nmAgentGeneralInfo 8 }
nmAKernelVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SPEED-NMS Kernel Version"
::= { nmAgentGeneralInfo 9 }
--*************************************************************
-- nmAgentConfig (2)
nmAgentConfig OBJECT IDENTIFIER ::= { nmAgent 2 }
--*************************************************************
-- nmAgentConfigNetwork (1)
nmAgentConfigNetwork OBJECT IDENTIFIER ::= { nmAgentConfig 1 }
nmAgentConfigNetworkIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP-address of the management boards Ethernet interface"
::= { nmAgentConfigNetwork 1 }
nmAgentConfigNetworkMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP-netmask of the management boards Ethernet interface"
::= { nmAgentConfigNetwork 2 }
nmAgentConfigNetworkGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"default gateway of the management boards Ethernet interface"
::= { nmAgentConfigNetwork 3 }
nmAgentConfigNetworkIPv6 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..50))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IPv6-address of the management boards Ethernet interface"
::= { nmAgentConfigNetwork 5 }
nmAgentConfigNetworkGatewayv6 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..50))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"default gatewayv6 of the management boards Ethernet interface"
::= { nmAgentConfigNetwork 6 }
--*************************************************************
-- nmAgentConfigSnmp (2)
nmAgentConfigSnmp OBJECT IDENTIFIER ::= { nmAgentConfig 2 }
nmAgentConfigSnmpReadCommunity OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SNMP read community name"
::= { nmAgentConfigSnmp 1 }
nmAgentConfigSnmpWriteCommunity OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SNMP write community name"
::= { nmAgentConfigSnmp 2 }
nmAgentConfigSnmpSysLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"location of the SPEED-CARRIER system"
::= { nmAgentConfigSnmp 3 }
nmAgentConfigSnmpSysContact OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"administrator of the SPEED-CARRIER system"
::= { nmAgentConfigSnmp 4 }
nmAgentConfigSnmpTrapSink1 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..50))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap destination 1 for SNMP traps. Clear value is 0.0.0.0"
::= { nmAgentConfigSnmp 5 }
nmAgentConfigSnmpTrapSink2 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..50))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap destination 2 for SNMP traps. Clear value is 0.0.0.0"
::= { nmAgentConfigSnmp 6 }
nmAgentConfigSnmpTrapSink3 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..50))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap destination 3 for SNMP traps. Clear value is 0.0.0.0"
::= { nmAgentConfigSnmp 7 }
nmAgentConfigSnmpTrapSink4 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..50))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap destination 4 for SNMP traps. Clear value is 0.0.0.0"
::= { nmAgentConfigSnmp 8 }
nmAgentConfigSnmpTrapSink5 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..50))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap destination 5 for SNMP traps. Clear value is 0.0.0.0"
::= { nmAgentConfigSnmp 9 }
nmAgentConfigSnmpAgent OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
snmpV1-V2c(1),
snmpV3(2),
notAvailable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"enable or disable the SNMP agent on the management board"
::= { nmAgentConfigSnmp 10 }
-- ****************************************************
nmAgentConfigSNMPv3UserConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF NMAgentConfigSNMPv3UserConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SNMPv3 user configuration table"
::= { nmAgentConfigSnmp 11 }
nmAgentConfigSNMPv3UserConfigEntry OBJECT-TYPE
SYNTAX NMAgentConfigSNMPv3UserConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SNMPv3 user configuration table"
INDEX { nmAgentConfigSNMPv3UserConfigIndex }
::= { nmAgentConfigSNMPv3UserConfigTable 1 }
NMAgentConfigSNMPv3UserConfigEntry ::= SEQUENCE
{
nmAgentConfigSNMPv3UserConfigIndex INTEGER,
nmAgentConfigSnmpv3UserConfigName DisplayString,
nmAgentConfigSnmpv3UserConfigUserLevel INTEGER,
nmAgentConfigSnmpv3UserConfigAuthType INTEGER,
nmAgentConfigSnmpv3UserConfigAuthPassPhrase DisplayString,
nmAgentConfigSnmpv3UserConfigEncType INTEGER,
nmAgentConfigSnmpv3UserConfigPrivPassPhrase DisplayString
}
nmAgentConfigSNMPv3UserConfigIndex OBJECT-TYPE
SYNTAX INTEGER (0..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"user index"
::= { nmAgentConfigSNMPv3UserConfigEntry 1 }
nmAgentConfigSnmpv3UserConfigName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"user name"
::= { nmAgentConfigSNMPv3UserConfigEntry 2 }
nmAgentConfigSnmpv3UserConfigUserLevel OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable(0),
rouser(1),
rwuser(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"user rights read-only (ro) or read-write (rw)"
::= { nmAgentConfigSNMPv3UserConfigEntry 3 }
nmAgentConfigSnmpv3UserConfigAuthType OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable(0),
mD5(1),
sHA(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"authentication types"
::= { nmAgentConfigSNMPv3UserConfigEntry 4 }
nmAgentConfigSnmpv3UserConfigAuthPassPhrase OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"authentication passphrase"
::= { nmAgentConfigSNMPv3UserConfigEntry 5 }
nmAgentConfigSnmpv3UserConfigEncType OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable(0),
dES(1),
aES(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"privacy protocols"
::= { nmAgentConfigSNMPv3UserConfigEntry 6 }
nmAgentConfigSnmpv3UserConfigPrivPassPhrase OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"privacy passphrase"
::= { nmAgentConfigSNMPv3UserConfigEntry 7 }
--*************************************************************
-- nmAgentConfigSlotAlarms(3)
nmAgentConfigSlotAlarmsTable OBJECT-TYPE
SYNTAX SEQUENCE OF NMAgentConfigSlotAlarmsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table for Slot 'alarm relay' configuration"
::= { nmAgentConfig 3 }
nmAgentConfigSlotAlarmsEntry OBJECT-TYPE
SYNTAX NMAgentConfigSlotAlarmsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"activate or deactivate slot for 'alarm relay' configuration"
INDEX { nmAgentConfigSlotAlarmsSlotNumber }
::= { nmAgentConfigSlotAlarmsTable 1 }
NMAgentConfigSlotAlarmsEntry ::= SEQUENCE
{
nmAgentConfigSlotAlarmsSlotNumber INTEGER,
nmAgentConfigSlotAlarmsInsertedCard DisplayString,
nmAgentConfigSlotAlarmsConfig INTEGER
}
nmAgentConfigSlotAlarmsSlotNumber OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number for alarm relay configuration"
::= { nmAgentConfigSlotAlarmsEntry 1 }
nmAgentConfigSlotAlarmsInsertedCard OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Card type of inserted card in this slot"
::= { nmAgentConfigSlotAlarmsEntry 2 }
nmAgentConfigSlotAlarmsConfig OBJECT-TYPE
SYNTAX INTEGER
{
alarmsEnabled(0),
alarmsDisabled(1),
fail(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set alarm reporting to 'on' or 'off' for this slot"
::= { nmAgentConfigSlotAlarmsEntry 3 }
--*************************************************************
-- nmAgentConfigModules (4)
nmAgentConfigSlotModulesTable OBJECT-TYPE
SYNTAX SEQUENCE OF NMAgentConfigSlotModulesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table for card configuration"
::= { nmAgentConfig 4 }
nmAgentConfigSlotModulesEntry OBJECT-TYPE
SYNTAX NMAgentConfigSlotModulesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table for card configuration"
INDEX { nmAgentConfigModulesSlotNumber }
::= { nmAgentConfigSlotModulesTable 1 }
NMAgentConfigSlotModulesEntry ::= SEQUENCE
{
nmAgentConfigModulesSlotNumber INTEGER,
nmAgentConfigModulesInstalledCard DisplayString,
nmAgentConfigModulesExpectedCard INTEGER,
nmAgentConfigModulesSlotText DisplayString,
nmAgentConfigModulesInstalledState DisplayString
}
nmAgentConfigModulesSlotNumber OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"slot number for card configuration"
::= { nmAgentConfigSlotModulesEntry 1 }
nmAgentConfigModulesInstalledCard OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Card type of inserted card in this slot"
::= { nmAgentConfigSlotModulesEntry 2 }
nmAgentConfigModulesExpectedCard OBJECT-TYPE
SYNTAX INTEGER
{
notConfigured(0),
speedCWDM21(11),
speedCWDM41(12),
speedCWDM41E(13),
speedCWDM51(14),
speedCWDM81(15),
speedCWDM81E(16),
speedCWDM91(17),
speedADCWDM(18),
oneSlotPassiveCard(19),
twoSlotPassiveCard(20),
speedNMS(50),
speedProtect3R(51),
speedDuallineSfp3R(52),
speedDuallineSfp(53),
speedSinglelineSfp(54),
speedSinglelineXFP3R(55),
speedSinglelineXFP(56),
speedDuallineFcXFP(57),
speedDuallineFcSfp(58),
speedDualline10GXFP(59),
speedDualline10GSfp(60),
speedDualline16GXFP(61),
speedDualline16GSfp(62),
speedAmpEdfaPREAMP14(101),
speedAmpEdfaBOOSTER17(102),
speedAmpEdfaBOOSTER17OSC(103),
speedAmpEdfaBOOSTER23OSC(104),
speedAmpEdfaINLINE17OSC(105),
speedAmpEdfaINLINE23OSC(106),
speedAmpRamanMASTER10(107),
speedAmpRamanMASTER15(108),
speedAmpRamanSLAVE10(109),
speedAmpRamanSLAVE15(110),
speedAmpRamanSTANDALONE10(111),
speedAmpRamanSTANDALONE15(112),
reserved(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set the type of card, which is inserted in slot"
::= { nmAgentConfigSlotModulesEntry 3 }
nmAgentConfigModulesSlotText OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set the user defined text for passive card, which is inserted in slot"
::= { nmAgentConfigSlotModulesEntry 4 }
nmAgentConfigModulesInstalledState OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Check the installed module against the expected module"
::= { nmAgentConfigSlotModulesEntry 5 }
--*************************************************************
-- nmAgentConfigAgentPorts (5) (for later RELEASE)
-- nmAgentConfigAgentPorts OBJECT IDENTIFIER ::= { nmAgentConfig 5 }
--*************************************************************
-- nmAgentConfig (2)
nmAgentConfigCarrierName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..60))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"name or location of the SPEED-CARRIER system"
::= { nmAgentConfig 6 }
nmAgentConfigAlarmRelay OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
psu(1),
fan(2),
psuFan(3),
slots(4),
psuSlots(5),
fanSlots(6),
psuFanSlots(7),
notAvailable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"configure alarm relay for different sources"
::= { nmAgentConfig 7 }
nmAgentConfigFAN OBJECT-TYPE
SYNTAX INTEGER
{
allOn(1),
auto(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"configure fans to 'allOn' or 'auto'"
::= { nmAgentConfig 8 }
nmAgentConfigNtpServer OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..50))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP address of the Network Time Protocol server. Clear value is '0.0.0.0'."
::= { nmAgentConfig 9 }
nmAgentConfigTftpServer OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1),
notAvailable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"enable or disable the TFTP server on the management board"
::= { nmAgentConfig 10 }
nmAgentConfigWebServer OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
http(1),
https(2),
notAvailable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"enable or disable the web server on the management board"
::= { nmAgentConfig 11 }
nmAgentConfigMyWebView OBJECT-TYPE
SYNTAX INTEGER
{
pictureAndDeviceList(1),
pictureAndActiveAlarms(2),
deviceListAndActiveAlarms(3),
notAvailable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"configures the start screen of WebView for the web interface"
::= { nmAgentConfig 12 }
nmAgentConfigPSU1Type OBJECT-TYPE
SYNTAX INTEGER
{
slotEmpty(0),
psu230VAC75W(1),
psu230VAC160W(2),
psu48VDC75W(3),
psu48VDC150W(4),
psu48VDC60W(5),
psu230VAC60W(6),
psu48VDC250W(7),
psu230VAC250W(8),
notDefined(254),
notAvailable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"configures the type of PSU 1"
::= { nmAgentConfig 13 }
nmAgentConfigPSU2Type OBJECT-TYPE
SYNTAX INTEGER
{
slotEmpty(0),
psu230VAC75W(1),
psu230VAC160W(2),
psu48VDC75W(3),
psu48VDC150W(4),
psu48VDC60W(5),
psu230VAC60W(6),
psu48VDC250W(7),
psu230VAC250W(8),
notDefined(254),
notAvailable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"configures the type of PSU 2"
::= { nmAgentConfig 14 }
nmAgentConfigTimezone OBJECT-TYPE
SYNTAX INTEGER
{
utc(0),
met(1),
notAvailable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"sets the system time zone. Has only effect after reboot"
::= { nmAgentConfig 15 }
nmAgentConfigAccess OBJECT-TYPE
SYNTAX INTEGER
{
unknown(0),
off(1),
telnet(2),
ssh2(3),
sshWithPreSharedKeys(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"sets system access to telnet, SSH version 2 or off"
::= { nmAgentConfig 16 }
nmAgentConfigCliTimeout OBJECT-TYPE
SYNTAX INTEGER (120..3600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"time without user interaction before exiting CLI. Valid range 120-3600 seconds."
::= { nmAgentConfig 17 }
nmAgentConfigRadiusServerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP address of the radius server"
::= { nmAgentConfig 18 }
nmAgentConfigRadiusStateConfig OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable(0),
useLocalPasswords(1),
useRadiusAuthentication(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP address of the radius server"
::= { nmAgentConfig 19 }
nmAgentConfigRadiusSharedSecret OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"shared secret for RADIUS server communication"
::= { nmAgentConfig 20 }
nmAgentConfigNMSState OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable(0),
running(1),
resetSystem(2),
resetConfig(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"running state of NMS module. Reboot is NOT traffic effecting!"
::= { nmAgentConfig 21 }
nmAgentConfigPSU1Text OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"configures passive text of PSU 1"
::= { nmAgentConfig 22 }
nmAgentConfigPSU2Text OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"configures passive text of PSU 2"
::= { nmAgentConfig 23 }
nmAgentConfigPSU3Text OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"configures passive text of PSU 3"
::= { nmAgentConfig 24 }
nmAgentConfigPSU3Type OBJECT-TYPE
SYNTAX INTEGER
{
slotEmpty(0),
psu48VDC250W(7),
psu230VAC250W(8),
notDefined(254),
notAvailable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"configures the type of PSU 3"
::= { nmAgentConfig 25 }
-- ****************************************************
nmAgentConfigRadiusServerConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF NMAgentConfigRadiusServerConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RADIUS server configuration table"
::= { nmAgentConfig 26 }
nmAgentConfigRadiusServerConfigEntry OBJECT-TYPE
SYNTAX NMAgentConfigRadiusServerConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RADIUS server configuration table"
INDEX { nmAgentConfigRadiusServerConfigNumber }
::= { nmAgentConfigRadiusServerConfigTable 1 }
NMAgentConfigRadiusServerConfigEntry ::= SEQUENCE
{
nmAgentConfigRadiusServerConfigNumber INTEGER,
nmAgentConfigRadiusServerConfigIPAddress DisplayString,
nmAgentConfigRadiusServerConfigSharedSecret DisplayString
}
nmAgentConfigRadiusServerConfigNumber OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"RADIUS server number"
::= { nmAgentConfigRadiusServerConfigEntry 1 }
nmAgentConfigRadiusServerConfigIPAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..50))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RADIUS server IPv4 or IPv6 address"
::= { nmAgentConfigRadiusServerConfigEntry 2 }
nmAgentConfigRadiusServerConfigSharedSecret OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RADIUS server shared secret"
::= { nmAgentConfigRadiusServerConfigEntry 3 }
--*************************************************************
nmAgentPortsStatus OBJECT IDENTIFIER ::= { nmAgent 3 }
nmAgentPort1OperStatus OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable(0),
notInserted(1),
up(2),
down(3),
txFault(4),
txDisabled(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"first SFP port operational status"
::= { nmAgentPortsStatus 1 }
nmAgentPort2OperStatus OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable(0),
notInserted(1),
up(2),
down(3),
txFault(4),
txDisabled(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"second SFP port operational status"
::= { nmAgentPortsStatus 2 }
--*************************************************************
-- nmCarrier (2)
nmCarrier OBJECT IDENTIFIER ::= { nmSPEEDCARRIER 2 }
--*************************************************************
-- nmCarrierGerneralInfo (1)
nmCarrierGerneralInfo OBJECT IDENTIFIER ::= { nmCarrier 1 }
nmCarrierName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"name or location of the SPEED-CARRIER system. Allowed characters are 0-9 a-z A-Z '-' and '_'"
::= { nmCarrierGerneralInfo 1 }
nmCarrierType OBJECT-TYPE
SYNTAX INTEGER
{
unknown (0),
carrier4U (1),
carrier1U (2),
carrier45U (3),
carrier5U (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of SPEED-CARRIER system (1U / 4 slots, 4U or 4,5U with 17 slots)"
::= { nmCarrierGerneralInfo 2 }
nmPSU1Status OBJECT-TYPE
SYNTAX INTEGER
{
notInstalled (0),
fail (1),
temperatureWarning (2),
pass (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of PSU 1"
::= { nmCarrierGerneralInfo 3 }
nmPSU2Status OBJECT-TYPE
SYNTAX INTEGER
{
notInstalled (0),
fail (1),
temperatureWarning (2),
pass (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of PSU 2"
::= { nmCarrierGerneralInfo 4 }
nmFanState OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable (0),
pass (3),
fail (4),
notInstalled (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fan state of the SPEED-CARRIER system"
::= { nmCarrierGerneralInfo 5 }
nmCarrierPSU1Type OBJECT-TYPE
SYNTAX INTEGER
{
notConfigured(0),
psu230VAC75W(1),
psu230VAC160W(2),
psu48VDC75W(3),
psu48VDC150W(4),
psu48VDC60W(5),
psu230VAC60W(6),
psu48VDC250W(7),
psu230VAC250W(8),
notAvailable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"type of PSU 1"
::= { nmCarrierGerneralInfo 6 }
nmCarrierPSU2Type OBJECT-TYPE
SYNTAX INTEGER
{
notConfigured(0),
psu230VAC75W(1),
psu230VAC160W(2),
psu48VDC75W(3),
psu48VDC150W(4),
psu48VDC60W(5),
psu230VAC60W(6),
psu48VDC250W(7),
psu230VAC250W(8),
notAvailable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"type of PSU 2"
::= { nmCarrierGerneralInfo 7 }
nmCarrierPSU1Text OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU 1 customer description"
::= { nmCarrierGerneralInfo 8 }
nmCarrierPSU2Text OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU 2 customer description"
::= { nmCarrierGerneralInfo 9 }
nmCarrierPSU3Text OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSU 3 customer description"
::= { nmCarrierGerneralInfo 10 }
nmCarrierPSU3Type OBJECT-TYPE
SYNTAX INTEGER
{
notConfigured(0),
psu230VAC75W(1),
psu230VAC160W(2),
psu48VDC75W(3),
psu48VDC150W(4),
psu48VDC60W(5),
psu230VAC60W(6),
psu48VDC250W(7),
psu230VAC250W(8),
notAvailable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"type of PSU 3"
::= { nmCarrierGerneralInfo 11 }
nmPSU3Status OBJECT-TYPE
SYNTAX INTEGER
{
notInstalled (0),
fail (1),
temperatureWarning (2),
pass (3),
notAvailable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of PSU 3"
::= { nmCarrierGerneralInfo 12 }
--*************************************************************
-- nmCarrierSlotOverviewTable (2)
nmCarrierSlotOverviewTable OBJECT-TYPE
SYNTAX SEQUENCE OF NMCarrierSlotOverviewEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Carrier slot overview table"
::= { nmCarrier 2 }
nmCarrierSlotOverviewEntry OBJECT-TYPE
SYNTAX NMCarrierSlotOverviewEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Carrier slot overview"
INDEX { nmCarrierSlotNumber }
::= { nmCarrierSlotOverviewTable 1 }
NMCarrierSlotOverviewEntry ::= SEQUENCE
{
nmCarrierSlotNumber INTEGER,
nmCarrierSlotType DisplayString,
nmCarrierSlotPassiveText DisplayString
}
nmCarrierSlotNumber OBJECT-TYPE
SYNTAX INTEGER (1..17)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot Number 1..17 for 4,xU Carrier or 1..4 for 1U Carrier"
::= { nmCarrierSlotOverviewEntry 1 }
nmCarrierSlotType OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"installed card type in this slot"
::= { nmCarrierSlotOverviewEntry 2 }
nmCarrierSlotPassiveText OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"user defined text for passive cards. Is only available, if passive card is configured"
::= { nmCarrierSlotOverviewEntry 3 }
--*************************************************************
-- nmFanOverview(3)
nmFanOverviewTable OBJECT-TYPE
SYNTAX SEQUENCE OF NMFanOverviewEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Fan overview table"
::= { nmCarrier 3 }
nmFanOverviewEntry OBJECT-TYPE
SYNTAX NMFanOverviewEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Fan overview table"
INDEX { nmFanGroupNumber }
::= { nmFanOverviewTable 1 }
NMFanOverviewEntry ::= SEQUENCE
{
nmFanGroupNumber INTEGER,
nmFanGroupStatus INTEGER
}
nmFanGroupNumber OBJECT-TYPE
SYNTAX INTEGER (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fan group number"
::= { nmFanOverviewEntry 1 }
nmFanGroupStatus OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable (0),
on (1),
off (2),
pass (3),
fail (4),
notInstalled (5),
auto(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For 1U Carrier group1 is the front fan and group2 the rear fan
For 4.5U Carrier: group 1 and 2 are PSU 1 and 2. group 3 is the
front fan below the slots and group 4 the rear fans."
::= { nmFanOverviewEntry 2 }
--**********************
-- nmCarrierFWUpdate(4)
nmCarrierFWUpdate OBJECT IDENTIFIER ::= { nmCarrier 4 }
nmCarrierFWUpdateFilename OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"filename for copying to slots"
::= { nmCarrierFWUpdate 1 }
nmCarrierFirmwareTransferConfig OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable(0),
idle(1),
startTransfer(2),
transferReady(3),
transferActive(4),
transferFailure(5),
abortTransfer(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control and status of upload procedure"
::= { nmCarrierFWUpdate 2 }
nmCarrierFWTransferProgress OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"copy progress in percent"
::= { nmCarrierFWUpdate 3 }
nmCarrierFWUpdateConfig OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable(0),
idle(1),
updateRunning(2),
updateReady(3),
copyToFlash(4),
copyToFlashAndRestart(5),
restartOnly(6),
updateFailure(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"copy and activates SW-images after next restart"
::= { nmCarrierFWUpdate 4 }
--**********************
nmCarrierFWUpdatePolicyTable OBJECT-TYPE
SYNTAX SEQUENCE OF NMCarrierFWUpdatePolicy
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"update policy table"
::= { nmCarrier 5 }
nmCarrierFWUpdatePolicyEntry OBJECT-TYPE
SYNTAX NMCarrierFWUpdatePolicy
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"update policy"
INDEX { nmCarrierFWUpdatePolicySlot }
::= { nmCarrierFWUpdatePolicyTable 1 }
NMCarrierFWUpdatePolicy ::= SEQUENCE
{
nmCarrierFWUpdatePolicySlot INTEGER,
nmCarrierFWUpdatePolicyCardName DisplayString,
nmCarrierFWUpdatePolicyConfig INTEGER,
nmCarrierFWUpdatePolicyTransferState INTEGER
}
nmCarrierFWUpdatePolicySlot OBJECT-TYPE
SYNTAX INTEGER (1..17)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"slot address"
::= { nmCarrierFWUpdatePolicyEntry 1 }
nmCarrierFWUpdatePolicyCardName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"card name"
::= { nmCarrierFWUpdatePolicyEntry 2 }
nmCarrierFWUpdatePolicyConfig OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable(0),
updatesEnabled(1),
updatesDisabled(2),
notApplicable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"enable or disable updates for this slot"
::= { nmCarrierFWUpdatePolicyEntry 3 }
nmCarrierFWUpdatePolicyTransferState OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable(0),
idle(1),
running(2),
ready(3),
fail(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"file transfer state"
::= { nmCarrierFWUpdatePolicyEntry 4 }
--**********************
nmCarrierConfigTransferTable OBJECT-TYPE
SYNTAX SEQUENCE OF NMCarrierFWConfigTransfer
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"update policy table"
::= { nmCarrier 6 }
nmCarrierConfigTransferEntry OBJECT-TYPE
SYNTAX NMCarrierFWConfigTransfer
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"update policy"
INDEX { nmCarrierConfigSlot }
::= { nmCarrierConfigTransferTable 1 }
NMCarrierFWConfigTransfer ::= SEQUENCE
{
nmCarrierConfigSlot INTEGER,
nmCarrierConfigModuleName DisplayString,
nmCarrierConfigTransferState INTEGER,
nmCarrierConfigTransfer INTEGER,
nmCarrierConfigFilename DisplayString,
nmCarrierConfigActivation INTEGER
}
nmCarrierConfigSlot OBJECT-TYPE
SYNTAX INTEGER (1..17)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module slot index"
::= { nmCarrierConfigTransferEntry 1 }
nmCarrierConfigModuleName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module name"
::= { nmCarrierConfigTransferEntry 2 }
nmCarrierConfigTransferState OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable (0),
upToDate (1),
fileUpdateScheduled (2),
updating (3),
invalidConfigFile (4),
error (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"config state"
::= { nmCarrierConfigTransferEntry 3 }
nmCarrierConfigTransfer OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable (0),
idle(1),
pushToSlot(2),
updateFromSlot(3),
transferReady(4),
transferRunning(5),
transferERROR(6),
abortTransfer(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"config command for transfering files"
::= { nmCarrierConfigTransferEntry 4 }
nmCarrierConfigFilename OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..256))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"actual stored config file or filename to be send"
::= { nmCarrierConfigTransferEntry 5 }
nmCarrierConfigActivation OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable(0),
idle(1),
activating(2),
ready(3),
copyToFlash(4),
copyToFlashAndRestart(5),
restartOnly(6),
failure(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"config file activation at slot"
::= { nmCarrierConfigTransferEntry 6 }
--*************************************************************
-- nmCarrierInventoryTable (7)
nmCarrierInventoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF NMCarrierInventoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Carrier inventory table"
::= { nmCarrier 7 }
nmCarrierInventoryEntry OBJECT-TYPE
SYNTAX NMCarrierInventoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Carrier inventory"
INDEX { nmCarrierInventoryIndex }
::= { nmCarrierInventoryTable 1 }
NMCarrierInventoryEntry ::= SEQUENCE
{
nmCarrierInventoryIndex INTEGER,
nmCarrierInventorySlotNumber INTEGER,
nmCarrierInventoryPort DisplayString,
nmCarrierInventoryModuleName DisplayString,
nmCarrierInventoryPartNumber DisplayString,
nmCarrierInventorySerialNumber DisplayString,
nmCarrierInventoryFirmwareRelease DisplayString,
nmCarrierInventoryKernelLoader DisplayString
}
nmCarrierInventoryIndex OBJECT-TYPE
SYNTAX INTEGER (1..18000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Inventory Index"
::= { nmCarrierInventoryEntry 1 }
nmCarrierInventorySlotNumber OBJECT-TYPE
SYNTAX INTEGER (1..17)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot Number 1..17 for 4,xU Carrier or 1..4 for 1U Carrier"
::= { nmCarrierInventoryEntry 2 }
nmCarrierInventoryPort OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port number in this slot"
::= { nmCarrierInventoryEntry 3 }
nmCarrierInventoryModuleName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"name of the module"
::= { nmCarrierInventoryEntry 4 }
nmCarrierInventoryPartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"part number"
::= { nmCarrierInventoryEntry 5 }
nmCarrierInventorySerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"serial number"
::= { nmCarrierInventoryEntry 6 }
nmCarrierInventoryFirmwareRelease OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"firmware release of the module"
::= { nmCarrierInventoryEntry 7 }
nmCarrierInventoryKernelLoader OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Kernel/Loader version of the module"
::= { nmCarrierInventoryEntry 8 }
--*******************************************************************
converter OBJECT IDENTIFIER ::= { nmSPEEDCARRIER 3 }
multiplexer OBJECT IDENTIFIER ::= { nmSPEEDCARRIER 4 }
amplifier OBJECT IDENTIFIER ::= { nmSPEEDCARRIER 5 }
convSPEEDDUALLINE OBJECT IDENTIFIER ::= { converter 1 }
--*******************************************************************
convSxLModuleOverviewTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConvSxLModuleOverviewEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SPEEDDUALLINE module overview table"
::= { convSPEEDDUALLINE 1 }
convSxLModuleOverviewEntry OBJECT-TYPE
SYNTAX ConvSxLModuleOverviewEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Module overview entries"
INDEX { convSxLMSlot }
::= { convSxLModuleOverviewTable 1 }
ConvSxLModuleOverviewEntry ::=
SEQUENCE
{
convSxLMSlot INTEGER,
convSxLMDevice INTEGER,
convSxLMStatus INTEGER,
convSxLMSysUpTime TimeTicks,
convSxLMTemp INTEGER,
convSxLMAlarmState INTEGER,
convSxLMBootSWVersion DisplayString,
convSxLMAppSWVersion DisplayString,
convSxLMHWVersion DisplayString,
convSxLMPLDVersion DisplayString,
convSxLMSerialNumber DisplayString
}
convSxLMSlot OBJECT-TYPE
SYNTAX INTEGER (1..17)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot No. in Carrier"
::= { convSxLModuleOverviewEntry 2 }
convSxLMDevice OBJECT-TYPE
SYNTAX INTEGER
{
devSPEEDSINGLELINE (0),
devSPEEDDUALLINE (1),
devSPEEDDUALLINE3R (2),
devSPEEDPROTECT3R (3),
devunknown (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module DeviceType"
::= { convSxLModuleOverviewEntry 3 }
convSxLMStatus OBJECT-TYPE
SYNTAX INTEGER
{
running (0),
resetHardware (1),
resetConfig (2),
resetCAN (3),
resetSoftware (4),
unknown (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Status of inserted module. resetSoftware does not affect traffic"
::= { convSxLModuleOverviewEntry 4 }
convSxLMSysUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System uptime in seconds"
::= { convSxLModuleOverviewEntry 5 }
convSxLMTemp OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module temperature"
::= { convSxLModuleOverviewEntry 6 }
convSxLMAlarmState OBJECT-TYPE
SYNTAX INTEGER
{
noAlarm (0),
activeAlarms (1),
unknown (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module alarm states, if they are active see Event-Table"
::= { convSxLModuleOverviewEntry 7 }
convSxLMBootSWVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module bootloader software version"
::= { convSxLModuleOverviewEntry 8 }
convSxLMAppSWVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module application software Version"
::= { convSxLModuleOverviewEntry 9 }
convSxLMHWVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module board hardware version"
::= { convSxLModuleOverviewEntry 10 }
convSxLMPLDVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module firmware version"
::= { convSxLModuleOverviewEntry 11 }
convSxLMSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..17))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modules serial number"
::= { convSxLModuleOverviewEntry 12 }
--************************Table**************************************
convSxLSWImagesOverviewTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConvSxLSWImagesOverviewEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SPEEDDUALLINE software images Overview Table"
::= { convSPEEDDUALLINE 2 }
convSxLSWImagesOverviewEntry OBJECT-TYPE
SYNTAX ConvSxLSWImagesOverviewEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Module overview entries"
INDEX { convSxLSWSlot }
::= { convSxLSWImagesOverviewTable 1 }
ConvSxLSWImagesOverviewEntry ::=
SEQUENCE
{
convSxLSWSlot INTEGER,
convSxLSWBootImage DisplayString,
convSxLSWAppImage1 DisplayString,
convSxLSWAppImage2 DisplayString,
convSxLSWUploadStatus INTEGER,
convSxLSWUpdateStatus INTEGER
}
convSxLSWSlot OBJECT-TYPE
SYNTAX INTEGER (1..17)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot No. in Carrier"
::= { convSxLSWImagesOverviewEntry 2 }
convSxLSWBootImage OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..36))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identification of bootimage"
::= { convSxLSWImagesOverviewEntry 3 }
convSxLSWAppImage1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..36))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identification of application image1"
::= { convSxLSWImagesOverviewEntry 4 }
convSxLSWAppImage2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..36))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identification of application image2"
::= { convSxLSWImagesOverviewEntry 5 }
convSxLSWUploadStatus OBJECT-TYPE
SYNTAX INTEGER
{
ready (0),
startUpload (1),
uploadActive (2),
uploadFailure (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Control and status of upload procedure"
::= { convSxLSWImagesOverviewEntry 6 }
convSxLSWUpdateStatus OBJECT-TYPE
SYNTAX INTEGER
{
idle (0),
activateImage1 (1),
activateImage2 (2),
invalidImages (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"activates SW-image after next reset"
::= { convSxLSWImagesOverviewEntry 7 }
--************************Table**************************************
convSxLModuleConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConvSxLModuleConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SPEEDDUALLINE config table"
::= { convSPEEDDUALLINE 3 }
convSxLModuleConfigEntry OBJECT-TYPE
SYNTAX ConvSxLModuleConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Module config entries"
INDEX { convSxLMSlot }
::= { convSxLModuleConfigTable 1 }
ConvSxLModuleConfigEntry ::=
SEQUENCE
{
convSxLMSlot INTEGER,
convSxLMIpAddress IpAddress,
convSxLMIpNetmask IpAddress,
convSxLMIpGateway IpAddress,
convSxLMIpTftpServer IpAddress,
convSxLMIpTrapSink IpAddress,
convSxLMSNMPReadCommunity DisplayString,
convSxLMSNMPWriteCommunity DisplayString,
convSxLMTempWarningLevel INTEGER,
convSxLMTempAlarmLevel INTEGER,
convSxLMAlarmReport INTEGER,
convSxLMEthPortConfig INTEGER,
convSxLMEthPortState INTEGER,
convSxLMCliUserTimeout INTEGER
}
convSxLMIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module IP address"
::= { convSxLModuleConfigEntry 3 }
convSxLMIpNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module netmask"
::= { convSxLModuleConfigEntry 4 }
convSxLMIpGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Default gateway"
::= { convSxLModuleConfigEntry 5 }
convSxLMIpTftpServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TFTP server address for SW-Update"
::= { convSxLModuleConfigEntry 6 }
convSxLMIpTrapSink OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SNMP TrapSink-address"
::= { convSxLModuleConfigEntry 7 }
convSxLMSNMPReadCommunity OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..17))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SNMP ReadCommunity"
::= { convSxLModuleConfigEntry 8 }
convSxLMSNMPWriteCommunity OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..17))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SNMP WriteCommunity"
::= { convSxLModuleConfigEntry 9 }
convSxLMTempWarningLevel OBJECT-TYPE
SYNTAX INTEGER(0..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Warning level for module ambient temperature (0 - 60 degree Celsius)"
::= { convSxLModuleConfigEntry 10 }
convSxLMTempAlarmLevel OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm level for module ambient temperature"
::= { convSxLModuleConfigEntry 11 }
convSxLMAlarmReport OBJECT-TYPE
SYNTAX INTEGER
{
disable (0),
toNMA (1),
toETH (2),
toNMAandETH (3),
notavailable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Controls alarm signaling modes of module"
::= { convSxLModuleConfigEntry 12 }
convSxLMEthPortConfig OBJECT-TYPE
SYNTAX INTEGER
{
unknown (0),
portDown (1),
portUp (2),
notavailable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Module Ethernet Port config"
::= { convSxLModuleConfigEntry 13 }
convSxLMEthPortState OBJECT-TYPE
SYNTAX INTEGER
{
unknown (0),
portDown (1),
portUp (2),
notavailable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module Ethernet Port state"
::= { convSxLModuleConfigEntry 14 }
convSxLMCliUserTimeout OBJECT-TYPE
SYNTAX INTEGER(120..3600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Module CLI User Timeout"
::= { convSxLModuleConfigEntry 15 }
--************************Table**************************************
convSxLModuleProtectionTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConvSxLModuleProtectionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SPEEDDUALLINE protection table"
::= { convSPEEDDUALLINE 4 }
convSxLModuleProtectionEntry OBJECT-TYPE
SYNTAX ConvSxLModuleProtectionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Protection table entries"
INDEX { convSxLMSlot }
::= { convSxLModuleProtectionTable 1 }
ConvSxLModuleProtectionEntry ::=
SEQUENCE
{
convSxLMSlot INTEGER,
convSxLMLinkProtectionConfig INTEGER,
convSxLMLinkProtectionStatus INTEGER,
convSxLMLinkProtectionFallback INTEGER
}
convSxLMLinkProtectionConfig OBJECT-TYPE
SYNTAX INTEGER
{
unknown(0),
fallbackPort1(1),
fallbackPort2(2),
staticPort1(3),
staticPort2(4),
protectionOFF(5),
notAvailable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Status of protection module"
::= { convSxLModuleProtectionEntry 3 }
convSxLMLinkProtectionStatus OBJECT-TYPE
SYNTAX INTEGER
{
unknown(0),
port1active(1),
port2active(2),
testing(3),
noneActive(4),
notAvailable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of protection functionality regarding the link port. The link port are always port1 (main) and port2 (backup). The local port is port4"
::= { convSxLModuleProtectionEntry 4 }
convSxLMLinkProtectionFallback OBJECT-TYPE
SYNTAX INTEGER(5..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fallback time of errorfree seconds before switching back to MainPath. If there is an error during the Fallback-Time the timer will be restarted again"
::= { convSxLModuleProtectionEntry 5 }
--************************Table**************************************
convSxLPortOverviewTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConvSxLPortOverviewEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Port status table"
::= { convSPEEDDUALLINE 5 }
convSxLPortOverviewEntry OBJECT-TYPE
SYNTAX ConvSxLPortOverviewEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Port status entries"
INDEX { convSxLPortIndex }
::= { convSxLPortOverviewTable 1 }
ConvSxLPortOverviewEntry ::=
SEQUENCE
{
convSxLPortIndex INTEGER,
convSxLSlot INTEGER,
convSxLPort INTEGER,
convSxLDescription DisplayString,
convSxLAdminState INTEGER,
convSxLOperState INTEGER,
convSxLAlarmState INTEGER,
convSxLSFPState INTEGER,
convSxLLLCFState INTEGER,
convSxLLoopState INTEGER,
convSxLSpeed INTEGER,
convSxLTxPortConnection INTEGER,
convSxLDMIState INTEGER
}
convSxLPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..1800)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port Index"
::= { convSxLPortOverviewEntry 1 }
convSxLSlot OBJECT-TYPE
SYNTAX INTEGER (1..17)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number"
::= { convSxLPortOverviewEntry 2 }
convSxLPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port number"
::= { convSxLPortOverviewEntry 3 }
convSxLDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port desription string"
::= { convSxLPortOverviewEntry 4 }
convSxLAdminState OBJECT-TYPE
SYNTAX INTEGER
{
adminDown (0),
adminUp (1),
notAvailable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port configuration mode"
::= { convSxLPortOverviewEntry 5 }
convSxLOperState OBJECT-TYPE
SYNTAX INTEGER
{
down(0),
up(1),
loop(2),
downLLCF(3),
downTxFault(4),
downRxLevel(5),
downTxLevel(6),
notAvailable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port operational state"
::= { convSxLPortOverviewEntry 6 }
convSxLSFPState OBJECT-TYPE
SYNTAX INTEGER
{
sfpRemoved (0),
sfpInstalled (1),
sfpTxFault (2),
notAvailable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SFP-Port state"
::= { convSxLPortOverviewEntry 7 }
convSxLLLCFState OBJECT-TYPE
SYNTAX INTEGER
{
off (0),
on (1),
notAvailable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of linkloss configuration"
::= { convSxLPortOverviewEntry 8 }
convSxLLoopState OBJECT-TYPE
SYNTAX INTEGER
{
off (0),
on (1),
notAvailable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of loop configuration"
::= { convSxLPortOverviewEntry 9 }
convSxLSpeed OBJECT-TYPE
SYNTAX INTEGER
{
speedTransparent (0),
speedSTM1-155Mbit (1),
speedSTM4-622Mbit (2),
speedSTM16-2488Mbit (3),
sSTM16FEC2666Mbit (4),
sFastEthernet125Mbit (5),
sGigabitEthernet1250Mbit (6),
sFibreChannel133Mbit (7),
sFibreChannel266Mbit (8),
sFibreChannel531Mbit (9),
sFibreChannel1062Mbit (10),
sFibreChannel2125Mbit (11),
sESCON200Mbit (12),
notAvailable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TxPort 3R regeneration speed and protocol"
::= { convSxLPortOverviewEntry 10 }
convSxLTxPortConnection OBJECT-TYPE
SYNTAX INTEGER
{
notConnected (0),
toPort1 (1),
toPort2 (2),
toPort3 (3),
toPort4 (4),
notAvailable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of port to port connection"
::= { convSxLPortOverviewEntry 11 }
convSxLAlarmState OBJECT-TYPE
SYNTAX INTEGER
{
noAlarm (0),
alarmLOS (1),
alarmCDR (2),
alarmTxFault (3),
alarmRxLevel (4),
warningRxLevel (5),
warningTxLevel (6),
activeAlarms (16),
activeWarnigs (32),
notAvailable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port warning / alarm states"
::= { convSxLPortOverviewEntry 12 }
convSxLDMIState OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable (0),
sff-8472Rev9-3 (1),
sff-8472Rev9-4 (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Availability or version of Diagnostic Monitoring Information (DMI)"
::= { convSxLPortOverviewEntry 13 }
--************************Table**************************************
convSxLPortConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConvSxLPortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Port config table"
::= { convSPEEDDUALLINE 6 }
convSxLPortConfigEntry OBJECT-TYPE
SYNTAX ConvSxLPortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Port config entry"
INDEX { convSxLPortIndex }
::= { convSxLPortConfigTable 1 }
ConvSxLPortConfigEntry ::=
SEQUENCE
{
convSxLPortIndex INTEGER,
convSxLSlot INTEGER,
convSxLPort INTEGER,
convSxLAdminConfig INTEGER,
convSxLLLCFConfig INTEGER,
convSxLLoopConfig INTEGER,
convSxLSpeedConfig INTEGER,
convSxLPortConnection INTEGER,
convSxLPortAlarmDeactivation INTEGER,
convSxLPortAlarmSchedule INTEGER
}
convSxLAdminConfig OBJECT-TYPE
SYNTAX INTEGER
{
adminDown (0),
adminUp (1),
notAvailable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Admin configuration of a specific port"
::= { convSxLPortConfigEntry 4 }
convSxLLLCFConfig OBJECT-TYPE
SYNTAX INTEGER
{
off (0),
on (1),
notAvailable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configuration of Link Loss Carry Forward (LLCF) function. If a link down event occurs on the link port the local port will be disabled to signal the error state to the locally connected device e.g. router"
::= { convSxLPortConfigEntry 5 }
convSxLLoopConfig OBJECT-TYPE
SYNTAX INTEGER
{
off (0),
on (1),
notAvailable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setup of loops. After a reset, all loops will be switched off"
::= { convSxLPortConfigEntry 6 }
convSxLSpeedConfig OBJECT-TYPE
SYNTAX INTEGER
{
speedTransparent (0),
speedSTM1-155Mbit (1),
speedSTM4-622Mbit (2),
speedSTM16-2488Mbit (3),
sSTM16FEC2666Mbit (4),
sFastEthernet125Mbit (5),
sGigabitEthernet1250Mbit (6),
sFibreChannel133Mbit (7),
sFibreChannel266Mbit (8),
sFibreChannel531Mbit (9),
sFibreChannel1062Mbit (10),
sFibreChannel2125Mbit (11),
sESCON200Mbit (12),
sVIDEO143Mbit (13),
sVIDEO177Mbit (14),
sVIDEO270Mbit (15),
sVIDEO360Mbit (16),
sVIDEO540Mbit (17),
sVIDEO1001Mbit (18),
sVIDEO1485Mbit (19),
sVIDEO2970Mbit (20),
notAvailable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TxPort 3R regeneration speed and protocol"
::= { convSxLPortConfigEntry 7 }
convSxLPortConnection OBJECT-TYPE
SYNTAX INTEGER
{
noConnection (0),
fromPort1 (1),
fromPort2 (2),
fromPort3 (3),
fromPort4 (4),
notPossible (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setup of connections. toPortx means a connection between Rx-input to Tx-output"
::= { convSxLPortConfigEntry 8 }
convSxLPortAlarmDeactivation OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable(0),
alarmReportingEnabled(1),
alarmReportingDisabledbySchedule(2),
alarmReportingDisabledPermanent(3),
unknown(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port alarm deactivation schedule"
::= { convSxLPortConfigEntry 9 }
convSxLPortAlarmSchedule OBJECT-TYPE
SYNTAX INTEGER (0..1200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port alarm deactivation schedule. Value in hours. After this time has elapsed, the alarms are active again. Valid range: 1..1200. 0 means less then 1 hour"
::= { convSxLPortConfigEntry 10 }
--*******************************************************************
convSxSFPIdentifikation OBJECT IDENTIFIER ::= { convSPEEDDUALLINE 7 }
--************************Table**************************************
convSXLSFPDescriptionTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConvSXLSFPDescriptionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Optical transceiver parameter table"
::= { convSxSFPIdentifikation 1 }
convSXLSFPDescriptionEntry OBJECT-TYPE
SYNTAX ConvSXLSFPDescriptionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Talbe entries"
INDEX { convSxLPortIndex }
::= { convSXLSFPDescriptionTable 1 }
ConvSXLSFPDescriptionEntry ::=
SEQUENCE
{
convSxLPortIndex INTEGER,
convSxLSlot INTEGER,
convSxLPort INTEGER,
convSxLSFPVendor DisplayString,
convSxLSFPVendorOUI DisplayString,
convSxLSFPVendorCode DisplayString,
convSxLSFPVendorRevisionCode DisplayString,
convSxLSFPVendorDateCode DisplayString,
convSxLSFPVendorSerialNumber DisplayString,
convSxLSFPType INTEGER,
convSxLSFPConnector INTEGER,
convSxLSFPWavelength DisplayString
}
convSxLSFPVendor OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SFP vendor name"
::= { convSXLSFPDescriptionEntry 4 }
convSxLSFPVendorOUI OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..3))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Vendor specific IEEE-OUI"
::= { convSXLSFPDescriptionEntry 5 }
convSxLSFPVendorCode OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..17))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Part identification code, vendor specific"
::= { convSXLSFPDescriptionEntry 6 }
convSxLSFPVendorRevisionCode OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..5))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Parts revision code, vendor specific"
::= { convSXLSFPDescriptionEntry 7 }
convSxLSFPVendorDateCode OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..9))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor date code for the transceiver. The date code is specified in the following format: YYYY.MM.DD/LL; YYYY = year; MM = month; DD = day of month; LL = vendor lot code"
::= { convSXLSFPDescriptionEntry 8 }
convSxLSFPVendorSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..17))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Parts serial number "
::= { convSXLSFPDescriptionEntry 9 }
convSxLSFPType OBJECT-TYPE
SYNTAX INTEGER
{
unspecified (0),
tGBIC (1),
tModuleSolderedToMotherboard (2),
tSFPTransceiver (3),
tDWDMSFPTransceiver (11),
tCopperSFPTransceiver(254),
vendorSpecific (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical type of device"
::= { convSXLSFPDescriptionEntry 10 }
convSxLSFPConnector OBJECT-TYPE
SYNTAX INTEGER
{
unspecified (0),
cSC (1),
cFibreChannelStyle1CopperConnector (2),
cFibreChannelStyle2CopperConnector (3),
cBncTnc (4),
cFibreChannerCoaxialHeader (5),
cFibreJack (6),
cLC (7),
cMTRJ (8),
cMU (9),
cSG (10),
cOpticalPigtail(11),
cHSSDCII (32),
cCopperPigtail (33),
cRJ45 (34),
unknown(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The connector value indicates the external connector provided on the interface."
::= { convSXLSFPDescriptionEntry 11 }
convSxLSFPWavelength OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The laser wavelength is the nominal transmitter output wavelength at room temperature. The value is in nanometers [nm]. This field allows the user to read the laser wavelength directly, so it is not necessary to infer it from the transceiver 'Code for Electronic Compatibility'."
::= { convSXLSFPDescriptionEntry 12 }
--************************Table**************************************
convSxLSFPBitrateTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConvSxLSFPBitrateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Optical transceiver bitrate table"
::= { convSxSFPIdentifikation 2 }
convSxLSFPBitrateEntry OBJECT-TYPE
SYNTAX ConvSxLSFPBitrateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Transceiver bitrate"
INDEX { convSxLPortIndex }
::= { convSxLSFPBitrateTable 1 }
ConvSxLSFPBitrateEntry ::=
SEQUENCE
{
convSxLPortIndex INTEGER,
convSxLSlot INTEGER,
convSxLPort INTEGER,
convSxLSFPBitrateNominal INTEGER,
convSxLSFPBitrateMax INTEGER,
convSxLSFPBitrateMin INTEGER
}
convSxLSFPBitrateNominal OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nominal bit rate is specified in units of 1 Megabit per second, rounded up to the next 100 Megabits per second. The bit rate includes those bits necessary to encode and delimit the signal as well as those bits carrying data information. A value of 0 indicates that the bit rate is not specified and must be determined from the transceiver technology. The actual information transfer rate will depend on the data encoding defined by the encoding value."
::= { convSxLSFPBitrateEntry 4 }
convSxLSFPBitrateMax OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The upper bit rate limit at which the SFP transceiver will still meet its specifications is specified in units of 1 Megabit per second. A value of 0 indicates that this field is not specified."
::= { convSxLSFPBitrateEntry 5 }
convSxLSFPBitrateMin OBJECT-TYPE
SYNTAX INTEGER
{
notAvailable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lower bit rate limit at which the SFP transceiver will still meet its specifications is specified in units of 1 Megabit per second. A value of 0 indicates that this field is not specified."
::= { convSxLSFPBitrateEntry 6 }
--************************Table**************************************
convSxLSFPLengthTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConvSxLSFPLengthEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Optical Transceiver Length Table"
::= { convSxSFPIdentifikation 3 }
convSxLSFPLengthEntry OBJECT-TYPE
SYNTAX ConvSxLSFPLengthEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Optical Transceiver Length Coding Entries"
INDEX { convSxLPortIndex }
::= { convSxLSFPLengthTable 1 }
ConvSxLSFPLengthEntry ::=
SEQUENCE
{
convSxLPortIndex INTEGER,
convSxLSlot INTEGER,
convSxLPort INTEGER,
convSxLSFPLength9km INTEGER,
convSxLSFPLength9m INTEGER,
convSxLSFPLength50 INTEGER,
convSxLSFPLength62 INTEGER,
convSxLSFPLengthCopper INTEGER
}
convSxLSFPLength9km OBJECT-TYPE
SYNTAX INTEGER
{
grater254km(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using single mode fiber. The value is in units of kilometers. A value of 255 means that the transceiver supports a link greater than 254 km. A value of 0 means that the transceiver does not support single mode fiber or that the length information must be determined from the transceiver technology."
::= { convSxLSFPLengthEntry 4 }
convSxLSFPLength9m OBJECT-TYPE
SYNTAX INTEGER
{
greater25km(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using single mode fiber. The value is in units of 100 meters. A value of 255 means that the transceiver supports a link greater than 25.4 km. A value of 0 means that the transceiver does not support single mode fiber or that the length information must be determined from the transceiver technology."
::= { convSxLSFPLengthEntry 5 }
convSxLSFPLength50 OBJECT-TYPE
SYNTAX INTEGER
{
greater2540m(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using 50 micron multi mode fiber. The value is in units of 10 meters. A value of 255 means that the transceiver supports a link greater than 2.54 km. A value of 0 means that the transceiver does not support 50 micron multi mode fiber or that the length information must be determined from the transceiver technology."
::= { convSxLSFPLengthEntry 6 }
convSxLSFPLength62 OBJECT-TYPE
SYNTAX INTEGER
{
greater2540m(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using 62.5 micron multi mode fiber. The value is in units of 10 meters. A value of 255 means that the transceiver supports a link greater than 2.54 km. A value of 0 means that the transceiver does not support 62.5 micron multi mode fiber or that the length information must be determined from the transceiver technology."
::= { convSxLSFPLengthEntry 7 }
convSxLSFPLengthCopper OBJECT-TYPE
SYNTAX INTEGER
{
greater254m(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using copper cable. The value is in units of 1 meter. A value of 255 means that the transceiver supports a link greater than 254 m. A value of 0 means that the transceiver does not support copper cable or that the length information must be determined from the transceiver technology. Further information about the cable design, equalization, and connectors is usually required to guarantee meeting of particular length information."
::= { convSxLSFPLengthEntry 8 }
--************************Table**************************************
convSxLSFPCompCodes OBJECT IDENTIFIER ::= { convSxSFPIdentifikation 4 }
--************************Table**************************************
convSxLSFPCompCodeSonetTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConvSxLSFPCompCodeSonetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Optical transceiver sonet compatibility table"
::= { convSxLSFPCompCodes 1 }
convSxLSFPCompCodeSonetEntry OBJECT-TYPE
SYNTAX ConvSxLSFPCompCodeSonetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Transceiver compatibility code entries"
INDEX { convSxLPortIndex }
::= { convSxLSFPCompCodeSonetTable 1 }
ConvSxLSFPCompCodeSonetEntry ::=
SEQUENCE
{
convSxLPortIndex INTEGER,
convSxLSlot INTEGER,
convSxLPort INTEGER,
convSxLSFPCSProtocol INTEGER,
convSxLSFPCSRange INTEGER,
convSxLSFPCSFiberType INTEGER
}
convSxLSFPCSProtocol OBJECT-TYPE
SYNTAX INTEGER
{
notSupported (0),
sOC3 (1),
sOC12 (2),
sOC48 (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Supported protocol"
::= { convSxLSFPCompCodeSonetEntry 4 }
convSxLSFPCSRange OBJECT-TYPE
SYNTAX INTEGER
{
notSupported (0),
short (1),
intermediate (2),
long (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical transceivers range"
::= { convSxLSFPCompCodeSonetEntry 5 }
convSxLSFPCSFiberType OBJECT-TYPE
SYNTAX INTEGER
{
notSupported (0),
multimode (1),
singlemode (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Supported fiber type"
::= { convSxLSFPCompCodeSonetEntry 6 }
--************************Table**************************************
convSxLSFPCompCodeGigabitEthernetTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConvSxLSFPCompCodeGigabitEthernetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Optical transceiver gigabit Ethernet compatibility table"
::= { convSxLSFPCompCodes 2 }
convSxLSFPCompCodeGigabitEthernetEntry OBJECT-TYPE
SYNTAX ConvSxLSFPCompCodeGigabitEthernetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entries"
INDEX { convSxLPortIndex }
::= { convSxLSFPCompCodeGigabitEthernetTable 1 }
ConvSxLSFPCompCodeGigabitEthernetEntry ::=
SEQUENCE
{
convSxLPortIndex INTEGER,
convSxLSlot INTEGER,
convSxLPort INTEGER,
convSxLSFPCGType INTEGER
}
convSxLSFPCGType OBJECT-TYPE
SYNTAX INTEGER
{
notSupported (0),
g1000BASE-SX (1),
g1000BASE-LX (2),
g1000BASE-CX (4),
g1000BASE-T (8),
g100Base-Fx (32),
g100Base-Fx-LX (48)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Supported protocol"
::= { convSxLSFPCompCodeGigabitEthernetEntry 4 }
--************************Table**************************************
convSxLSFPCompCodeFibreChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConvSxLSFPCompCodeFibreChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Optical transceiver fibre channel compatibility table"
::= { convSxLSFPCompCodes 3 }
convSxLSFPCompCodeFibreChannelEntry OBJECT-TYPE
SYNTAX ConvSxLSFPCompCodeFibreChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entries"
INDEX { convSxLPortIndex }
::= { convSxLSFPCompCodeFibreChannelTable 1 }
ConvSxLSFPCompCodeFibreChannelEntry ::=
SEQUENCE
{
convSxLPortIndex INTEGER,
convSxLSlot INTEGER,
convSxLPort INTEGER,
convSxLSFPCFcMedia INTEGER,
convSxLSFPCFcTech INTEGER,
convSxLSFPCFcLinkLength INTEGER,
convSxLSFPCFcSpeed INTEGER
}
convSxLSFPCFcMedia OBJECT-TYPE
SYNTAX INTEGER
{
mnotSupported (0),
mSingleMode (1),
reserved (2),
mMultiMode50 (4),
mMultiMode62-5 (8),
mMultiMode50m-62-5m(12),
mVideoCoax (16),
mMiniatureCoax (32),
mShieldedTwistedPair (64),
mTwinAxialPair (128)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Supported media types"
::= { convSxLSFPCompCodeFibreChannelEntry 4 }
convSxLSFPCFcTech OBJECT-TYPE
SYNTAX INTEGER
{
notSupported (0),
tLongwaveLaserLL (10),
tLongwaveLaserLC (11),
tShortwaveLaserW-OFC (12),
tShortwaveLaserW-O-OFC (13),
tElectricalInterenclosure (20),
tElectricalIntraenclosure (21)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitter technology"
::= { convSxLSFPCompCodeFibreChannelEntry 5 }
convSxLSFPCFcLinkLength OBJECT-TYPE
SYNTAX INTEGER
{
notSupported (0),
longDistance (16),
intermediateDistance (32),
shortDistance (64),
verylongDistance (128)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link length supported by transceiver"
::= { convSxLSFPCompCodeFibreChannelEntry 6 }
convSxLSFPCFcSpeed OBJECT-TYPE
SYNTAX INTEGER
{
notSupported(0),
fcSpeed100MByte(1),
fcSpeed200MByte(4),
fcSpeed100-200MByte(5),
fcSpeed400MByte(16),
fcSpeed100-200-400MByte(21)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fibre channel speed"
::= { convSxLSFPCompCodeFibreChannelEntry 7 }
--************************Table**************************************
convSxLCopperSFPTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConvSxLCopperSFPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Overview and configuration of copper SFP table"
::= { convSxSFPIdentifikation 5 }
convSxLCopperSFPEntry OBJECT-TYPE
SYNTAX ConvSxLCopperSFPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Transceiver overview and configuration entries"
INDEX { convSxLPortIndex }
::= { convSxLCopperSFPTable 1 }
ConvSxLCopperSFPEntry ::=
SEQUENCE
{
convSxLPortIndex INTEGER,
convSxLSlot INTEGER,
convSxLPort INTEGER,
convSxLConfigSpeed INTEGER,
convSxLConfigDuplex INTEGER,
convSxLCuPhyId INTEGER,
convSxLCuSFPLink INTEGER,
convSxLCuSFPSpeed INTEGER,
convSxLCuSFPDuplex INTEGER,
convSxLCuSFPAutoMDIx INTEGER,
convSxLCuSFPConfigMode INTEGER
}
convSxLConfigSpeed OBJECT-TYPE
SYNTAX INTEGER
{
s10Mbit (1),
s100Mbit (2),
s1000Mbit (3),
notSupported (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User defined configuration of speed"
::= { convSxLCopperSFPEntry 3 }
convSxLConfigDuplex OBJECT-TYPE
SYNTAX INTEGER
{
halfduplex (1),
fullduplex (2),
notSupported (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User defined configuration of duplex mode"
::= { convSxLCopperSFPEntry 4 }
convSxLCuPhyId OBJECT-TYPE
SYNTAX INTEGER
{
unknown (0),
marvellPhy (1),
notSupported (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical transceiver installed in SFP, if unkown the transceiver is not supported"
::= { convSxLCopperSFPEntry 5 }
convSxLCuSFPLink OBJECT-TYPE
SYNTAX INTEGER
{
down (0),
up (1),
notSupported (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link status of internal physical in copper SFP"
::= { convSxLCopperSFPEntry 6 }
convSxLCuSFPSpeed OBJECT-TYPE
SYNTAX INTEGER
{
down (0),
s10Mbit (1),
s100Mbit (2),
s1000Mbit (3),
notSupported (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"actual speed status of internal physical in copper SFP"
::= { convSxLCopperSFPEntry 7 }
convSxLCuSFPDuplex OBJECT-TYPE
SYNTAX INTEGER
{
down (0),
halfduplex (1),
fullduplex (2),
notSupported (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"actual duplex mode status of internal physical in copper SFP"
::= { convSxLCopperSFPEntry 8 }
convSxLCuSFPAutoMDIx OBJECT-TYPE
SYNTAX INTEGER
{
on (0),
off (1),
notSupported (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"actual of status MDI-connection in copper SFP"
::= { convSxLCopperSFPEntry 9 }
convSxLCuSFPConfigMode OBJECT-TYPE
SYNTAX INTEGER
{
unknown (0),
auto (1),
forced (2),
notSupported (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"actual config mode in copper SFP"
::= { convSxLCopperSFPEntry 10 }
--************************Table**************************************
convSxLDWDMSFPTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConvSxLDWDMSFPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Overview and configuration of DWDM SFP table"
::= { convSxSFPIdentifikation 6 }
convSxLDWDMSFPEntry OBJECT-TYPE
SYNTAX ConvSxLDWDMSFPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Transceiver overview and configuration entries"
INDEX { convSxLPortIndex }
::= { convSxLDWDMSFPTable 1 }
ConvSxLDWDMSFPEntry ::=
SEQUENCE
{
convSxLPortIndex INTEGER,
convSxLSlot INTEGER,
convSxLPort INTEGER,
convSxLDWDMPowerClass INTEGER,
convSxLDWDMMaxSupplyCurrent INTEGER,
convSxLChannelSpacing INTEGER,
convSxLNumberofChannels INTEGER
}
convSxLDWDMPowerClass OBJECT-TYPE
SYNTAX INTEGER
{
p-upto1W (0),
p-between1Wand1-5W (1),
p-morethan1-5W (2),
notSupported (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power class of installed DWDM-SFP "
::= { convSxLDWDMSFPEntry 4 }
convSxLDWDMMaxSupplyCurrent OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defines the maximum supply current the module will consume under worst conditions in units of 4mA"
::= { convSxLDWDMSFPEntry 5 }
convSxLChannelSpacing OBJECT-TYPE
SYNTAX INTEGER
{
g200GHz (0),
g100GHz (1),
g50GHz (2),
notSupported (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the densest channel spacing the module is compatible with"
::= { convSxLDWDMSFPEntry 6 }
convSxLNumberofChannels OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the number of channels over which the module may be tuned by user command. If not tunable the number is 1"
::= { convSxLDWDMSFPEntry 7 }
--************************Table**************************************
convSxLSFPDMIParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConvSxLSFPDMIParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Optical transceiver measurement parameter table"
::= { convSPEEDDUALLINE 8 }
convSxLSFPDMIParamEntry OBJECT-TYPE
SYNTAX ConvSxLSFPDMIParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entries"
INDEX { convSxLPortIndex }
::= { convSxLSFPDMIParamTable 1 }
ConvSxLSFPDMIParamEntry ::=
SEQUENCE
{
convSxLPortIndex INTEGER,
convSxLSlot INTEGER,
convSxLPort INTEGER,
convSxLSFPDMIRxLevel INTEGER,
convSxLSFPDMIRxHighAlarm INTEGER,
convSxLSFPDMITxLevel INTEGER,
convSxLSFPDMITxBias INTEGER,
convSxLSFPDMIVcc INTEGER,
convSxLSFPDMITemp INTEGER
}
convSxLSFPDMIRxLevel OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical receive power "
::= { convSxLSFPDMIParamEntry 4 }
convSxLSFPDMIRxHighAlarm OBJECT-TYPE
SYNTAX INTEGER
{
normal (0),
active (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of receive optical power, active when overloaded"
::= { convSxLSFPDMIParamEntry 5 }
convSxLSFPDMITxLevel OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical transmit power "
::= { convSxLSFPDMIParamEntry 6 }
convSxLSFPDMITxBias OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transceiver hardware parameter: laser bias current"
::= { convSxLSFPDMIParamEntry 7 }
convSxLSFPDMIVcc OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transceiver hardware parameter: supply voltage"
::= { convSxLSFPDMIParamEntry 8 }
convSxLSFPDMITemp OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transceiver hardware parameter: temperature value"
::= { convSxLSFPDMIParamEntry 9 }
--************************Table**************************************
convSxLSFPDMIThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConvSxLSFPDMIThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Optical transceiver measurement threshold table"
::= { convSPEEDDUALLINE 9 }
convSxLSFPDMIThresholdEntry OBJECT-TYPE
SYNTAX ConvSxLSFPDMIThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Measurement parameter overview"
INDEX { convSxLPortIndex }
::= { convSxLSFPDMIThresholdTable 1 }
ConvSxLSFPDMIThresholdEntry ::=
SEQUENCE
{
convSxLPortIndex INTEGER,
convSxLSlot INTEGER,
convSxLPort INTEGER,
convSxLSFPDMIRxLowThresholdWarningLevel INTEGER,
convSxLSFPDMIRxLowThresholdAlarmLevel INTEGER,
convSxLSFPDMITxLowThresholdWarningLevel INTEGER,
convSxLSFPDMITxLowThresholdAlarmLevel INTEGER,
convSxLSFPDMIThresholdsUsage INTEGER
}
convSxLSFPDMIRxLowThresholdWarningLevel OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Optical receive power warning level. Value display and set is dBm/100"
::= { convSxLSFPDMIThresholdEntry 4 }
convSxLSFPDMIRxLowThresholdAlarmLevel OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical receive power alarm level. Value display is dBm/100"
::= { convSxLSFPDMIThresholdEntry 5 }
convSxLSFPDMITxLowThresholdWarningLevel OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Optical transmit power warning level. Value display and set is dBm/100"
::= { convSxLSFPDMIThresholdEntry 6 }
convSxLSFPDMITxLowThresholdAlarmLevel OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical transmit power alarm level. Value display is dBm/100"
::= { convSxLSFPDMIThresholdEntry 7 }
convSxLSFPDMIThresholdsUsage OBJECT-TYPE
SYNTAX INTEGER
{
userDefinedThresholds (0),
sFPVendorThresholds(1),
notAvailable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set threshold usage. Activate user defined or vendor defined thresholds"
::= { convSxLSFPDMIThresholdEntry 8 }
--************************Table**************************************
convSxLPortEventTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConvSxLPortEventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Port event Table"
::= { convSPEEDDUALLINE 10 }
convSxLPortEventEntry OBJECT-TYPE
SYNTAX ConvSxLPortEventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Port event table entries"
INDEX { convSxLPortIndex }
::= { convSxLPortEventTable 1 }
ConvSxLPortEventEntry ::=
SEQUENCE
{
convSxLPortIndex INTEGER,
convSxLSlot INTEGER,
convSxLPort INTEGER,
convSxLSFPDMIRxLowWarningEvent INTEGER,
convSxLSFPDMIRxLowAlarmEvent INTEGER,
convSxLSFPDMITxLowWarningEvent INTEGER,
convSxLSFPDMITxLowAlarmEvent INTEGER,
convSxLSFPDMIBiasAlarmEvent INTEGER,
convSxLSFPDMIRxHighAlarmEvent INTEGER,
convSxLSFPDWDMLaserTHighAlarmEvent INTEGER,
convSxLSFPDWDMLaserTLowAlarmEvent INTEGER,
convSxLSFPDWDMTECHighAlarmEvent INTEGER,
convSxLSFPDWDMTECLowAlarmEvent INTEGER,
convSxLSFPDMITempHighWarningEvent INTEGER,
convSxLSFPDMITempHighAlarmEvent INTEGER
}
convSxLSFPDMIRxLowWarningEvent OBJECT-TYPE
SYNTAX INTEGER
{
normal (0),
active (1),
notimplemented (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receive power - low warning"
::= { convSxLPortEventEntry 4 }
convSxLSFPDMIRxLowAlarmEvent OBJECT-TYPE
SYNTAX INTEGER
{
normal (0),
active (1),
notimplemented (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receive power - low alarm"
::= { convSxLPortEventEntry 5 }
convSxLSFPDMITxLowWarningEvent OBJECT-TYPE
SYNTAX INTEGER
{
normal (0),
active (1),
notimplemented (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Output power - low warning"
::= { convSxLPortEventEntry 6 }
convSxLSFPDMITxLowAlarmEvent OBJECT-TYPE
SYNTAX INTEGER
{
normal (0),
active (1),
notimplemented (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Output power - low alarm"
::= { convSxLPortEventEntry 7 }
convSxLSFPDMIBiasAlarmEvent OBJECT-TYPE
SYNTAX INTEGER
{
normal (0),
active (1),
notimplemented (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitter bias current is low"
::= { convSxLPortEventEntry 8 }
convSxLSFPDMIRxHighAlarmEvent OBJECT-TYPE
SYNTAX INTEGER
{
normal (0),
active (1),
notimplemented (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receiver input power is high"
::= { convSxLPortEventEntry 9 }
convSxLSFPDWDMLaserTHighAlarmEvent OBJECT-TYPE
SYNTAX INTEGER
{
normal (0),
active (1),
notimplemented (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Set when laser temperature or wavelength exceeds high alarm level."
::= { convSxLPortEventEntry 10 }
convSxLSFPDWDMLaserTLowAlarmEvent OBJECT-TYPE
SYNTAX INTEGER
{
normal (0),
active (1),
notimplemented (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Set when laser temperature or wavelength exceeds low alarm level."
::= { convSxLPortEventEntry 11 }
convSxLSFPDWDMTECHighAlarmEvent OBJECT-TYPE
SYNTAX INTEGER
{
normal (0),
active (1),
notimplemented (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Set when TEC current exceeds high alarm level (cooling problem)"
::= { convSxLPortEventEntry 12 }
convSxLSFPDWDMTECLowAlarmEvent OBJECT-TYPE
SYNTAX INTEGER
{
normal (0),
active (1),
notimplemented (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Set when TEC current exceeds low alarm level (heating problem)"
::= { convSxLPortEventEntry 13 }
convSxLSFPDMITempHighWarningEvent OBJECT-TYPE
SYNTAX INTEGER
{
normal (0),
active (1),
notimplemented (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transceiver DMI temperature high warning event"
::= { convSxLPortEventEntry 14 }
convSxLSFPDMITempHighAlarmEvent OBJECT-TYPE
SYNTAX INTEGER
{
normal (0),
active (1),
notimplemented (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transceiver DMI temperature high alarm event"
::= { convSxLPortEventEntry 15 }
--************************Table**************************************
convSxLInventoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConvSxLInventoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of all serial numbers installed in module"
::= { convSPEEDDUALLINE 11 }
convSxLInventoryEntry OBJECT-TYPE
SYNTAX ConvSxLInventoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entries"
INDEX { convSxLMSlot }
::= { convSxLInventoryTable 1 }
ConvSxLInventoryEntry ::=
SEQUENCE
{
convSxLMSlot INTEGER,
convSxLModuleSerialNumber DisplayString,
convSxLSFPPort1SerialNumber DisplayString,
convSxLSFPPort2SerialNumber DisplayString,
convSxLSFPPort3SerialNumber DisplayString,
convSxLSFPPort4SerialNumber DisplayString
}
convSxLModuleSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..17))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial number of module "
::= { convSxLInventoryEntry 3 }
convSxLSFPPort1SerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..17))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial number of installed transceiver"
::= { convSxLInventoryEntry 4 }
convSxLSFPPort2SerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..17))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial number of installed transceiver"
::= { convSxLInventoryEntry 5 }
convSxLSFPPort3SerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..17))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial number of installed transceiver"
::= { convSxLInventoryEntry 6 }
convSxLSFPPort4SerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..17))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial number of installed transceiver"
::= { convSxLInventoryEntry 7 }
--*****************************************************************
--************* Trap's ****************************************
coldStart TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot}
DESCRIPTION
"ColdStart"
::= 40
reboot TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot}
DESCRIPTION
"Reboot"
::= 41
fanError TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot}
DESCRIPTION
"FANError"
::= 42
fanOK TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot}
DESCRIPTION
"FANOK"
::= 43
powerFailure TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot }
DESCRIPTION
"PowerFailure"
::= 44
powerOK TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot }
DESCRIPTION
"PowerOK"
::= 45
highTemp TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"HighTemp"
::= 46
tempOK TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"TempOK"
::= 47
transceiverRemoved TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"SFPRemoved"
::= 48
transceiverInserted TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"SFPInserted"
::= 49
moduleInserted TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot}
DESCRIPTION
"ModuleInserted"
::= 50
moduleRemoved TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot}
DESCRIPTION
"ModuleRemoved"
::= 51
portTxUp TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"PortTxUp"
::= 52
portTxDown TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"PortTxDown"
::= 53
portUp TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"PortUp"
::= 54
portDown TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"PortDown"
::= 55
txFault TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"TxFault"
::= 56
badPasswd TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot }
DESCRIPTION
"BadPasswd"
::= 57
softwareUpdateReady TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot }
DESCRIPTION
"SoftwareUpdateReady"
::= 58
hardwareTrap TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot }
DESCRIPTION
"HardwareTrap"
::= 59
cdrAlarm TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot }
DESCRIPTION
"CDRAlarm"
::= 60
protectionMain TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"ProtectionMain"
::= 61
protectionBackup TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"ProtectionBackup"
::= 62
optRxLevelWarning TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"OptRxLevelWarning"
::= 63
optRxLevelAlarm TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"OptRxLevelAlarm"
::= 64
optRxLevelOK TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"OptRxLevelOK"
::= 65
optTxLevelWarning TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"OptTxLevelWarning"
::= 66
optTxLevelAlarm TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"OptTxLevelAlarm"
::= 67
optTxLevelOK TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"OptTxLevelOK"
::= 68
optTxBiasAlarm TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"TX Bias Alarm"
::= 69
optTxBiasOK TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"TX Bias OK"
::= 70
optRxPowerOverload TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"High optical input power Alarm"
::= 71
configError TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"Configuration error. An set command or config file transfer was not successful."
::= 72
configuration TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"Configuration file information"
::= 73
maintenance TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"Maintennance Change"
::= 74
ampFail TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"AMP error is occured"
::= 75
ampOk TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"AMP error is cleared"
::= 76
dwdmAlarm TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"DWDM transceiver alarm occured"
::= 77
dwdmOk TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"DWDM transceiver alarm cleared"
::= 78
firmwareError TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"firmware or kernel transfer or flashing error"
::= 79
unspecified TRAP-TYPE
ENTERPRISE PanDacom
VARIABLES { Descr, Slot, Port }
DESCRIPTION
"Unspecified"
::= 255
END